WorldWideScience

Sample records for objectivesto assess indoor

  1. Indoor Climate Quality Assessment -

    DEFF Research Database (Denmark)

    Ansaldi, Roberta; Asadi, Ehsan; Costa, José Joaquim

    This Guidebook gives building professionals useful support in the practical measurements and monitoring of the indoor climate in buildings. It is evident that energy consumption in a building is directly influenced by required and maintained indoor comfort level. Wireless technologies for measure...... for measurement and monitoring have allowed a significantly increased number of possible applications, especially in existing buildings. The Guidebook illustrates several cases with the instrumentation of the monitoring and assessment of indoor climate.......This Guidebook gives building professionals useful support in the practical measurements and monitoring of the indoor climate in buildings. It is evident that energy consumption in a building is directly influenced by required and maintained indoor comfort level. Wireless technologies...

  2. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y.; Kovanen, K. [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1995-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  3. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y; Kovanen, K [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1996-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  4. Assessment of external dose indoors in Lithuania

    International Nuclear Information System (INIS)

    Pilkyte, L.; Butkus, D.; Morkunas, G.

    2006-01-01

    The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y -1 . The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials. (authors)

  5. Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM), released in 2002, is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  6. Safety assessment of indoor live fire range, May 1989

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the indoor live fire range (LFR) at EG&G Mound Applied Technology plant. The purpose of the indoor LFR is to conduct training with live ammunition for all designated personnel. The SA examines the risks that are attendant to the operation of an indoor LFR for this purpose.

  7. Source specific risk assessment of indoor aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Koivisto, A.J.

    2013-05-15

    In the urban environment, atmospheric aerosols consist mainly of pollutants from anthropogenic sources. The majority of these originate from traffic and other combustion processes. A fraction of these pollutants will penetrate indoors via ventilation. However, indoor air concentrations are usually predominated by indoor sources due to the small amount of dilution air. In modern societies, people spend most of their time indoors. Thus, their exposure is controlled mainly by indoor concentrations from indoor sources. During the last decades, engineering of nanosized structures has created a new field of material science. Some of these materials have been shown to be potentially toxic to human health. The greatest potential for exposure to engineered nanomaterials (ENMs) occurs in the workplace during production and handling of ENMs. In an exposure assessment, both gaseous and particulate matter pollutants need to be considered. The toxicities of the particles usually depend on the source and age. With time, particle morphology and composition changes due to their tendency to undergo coagulation, condensation and evaporation. The PM exposure risk is related to source specific emissions, and thus, in risk assessment one needs to define source specific exposures. This thesis describes methods for source specific risk assessment of airborne particulate matter. It consists of studies related to workers' ENM exposures during the synthesis of nanoparticles, packing of agglomerated TiO{sub 2} nanoparticles, and handling of nanodiamonds. Background particles were distinguished from the ENM concentrations by using different measurement techniques and indoor aerosol modelings. Risk characterization was performed by using a source specific exposure and calculated dose levels in units of particle number and mass. The exposure risk was estimated by using non-health based occupational exposure limits for ENMs. For the nanosized TiO{sub 2}, the risk was also assessed from dose

  8. Indoor Air Quality Building Education and Assessment Model Forms

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  9. Reevaluation of time spent indoors used for exposure dose assessment

    International Nuclear Information System (INIS)

    Hirose, Katsumi; Fujimoto, Kenzo

    2016-01-01

    A time spent indoors of sixteen hours per day (indoor occupancy factor: 0.67) has been used to assess the radiation dose of residents who spend daily life in the area contaminated due to the nuclear accident in Japan. However, much longer time is considered to be spent indoors for recent modern life. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has been used an indoor occupancy factor of 0.8 since 1977 and a few reports suggested much higher indoor occupancy factors. Therefore it is important to reevaluate the indoor occupancy factor using current available survey data in Japan, such as 'NHK 2010 National Time Use Survey' and 'Survey on Time Use and Leisure Activities' of Statistics Bureau with certain assumption of time spent indoors in each daily activity. The total time spent indoors in a day is calculated to be 20.2 hours and its indoor occupancy factor is 0.84. Much lower indoor occupancy factors were derived from the survey data by Statistics Bureau for 10 to 14 and 15 to 19 years old groups and farmers who spend most of their time outdoors although present estimated indoor occupancy factor of 0.84 is still lower than those found in some of the relevant reports. A rounded indoor occupancy factor of 0.80 might be the appropriate conservative reference value to be used for the dose estimation of people who live in radioactively contaminated areas and for other relevant purposes of exposure assessment, taken into consideration the present results and values reported in United States Environmental Protection Agency (US EPA) and UNSCEAR. (author)

  10. Indoor air quality investigation and health risk assessment at correctional institutions.

    Science.gov (United States)

    Ofungwu, Joseph

    2005-04-01

    A comprehensive indoor air-quality (IAQ) investigation was conducted at a state correctional facility in New Jersey, USA with a lengthy history of IAQ problems. The IAQ investigation comprised preliminary indoor air screening using direct readout instrumentation, indoor air/surface wipe sampling and laboratory analysis, as well as a heating, ventilation, and air-conditioning system evaluation, and a building envelope survey. In addition to air sampling, a human health risk assessment was performed to evaluate the potential for exposure to site-related air contaminants with respect to the inmate and worker populations. The risk assessment results for the prison facility indicated the potential for significant health risks for the inmate population, possibly reflecting the effects of their confinement and extended exposure to indoor air contaminants, as compared to the prison guard and worker population. Based on the results of the risk assessment, several mitigation measures are recommended to minimize prison population health risks and improve indoor air quality at prison facilities.

  11. A Realistic Human Exposure Assessment of Indoor Radon released from Groundwater

    International Nuclear Information System (INIS)

    Yu, Dong Han; Han, Moon Hee

    2002-01-01

    The work presents a realistic human exposure assessment of indoor radon released from groundwater in a house. At first, a two-compartment model is developed to describe the generation and transfer of radon in indoor air from groundwater. The model is used to estimate radon concentrations profile of indoor air in a house using by showering, washing clothes, and flushing toilets. Then, the study performs an uncertainty analysis of model input parameters to quantify the uncertainty in radon concentration profile. In order to estimate a daily internal dose of a specific tissue group in an adult through the inhalation of such indoor radon, a PBPK(Physiologically-Based Pharmaco-Kinetic) model is developed. Combining indoor radon profile and PBPK model is used to a realistic human assessment for such exposure. The results obtained from this study would be used to the evaluation of human risk by inhalation associated with the indoor radon released from groundwater

  12. Bibliography for the Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  13. Indoor air - assessment: Methods of analysis for environmental carcinogens

    International Nuclear Information System (INIS)

    Peterson, M.R.; Naugle, D.F.; Berry, M.A.

    1990-06-01

    The monograph describes, in a general way, published sampling procedures and analytical approaches for known and suspected carcinogens. The primary focus is upon carcinogens found in indoor air, although the methods described are applicable to other media or environments. In cases where there are no published methods for a particular pollutant in indoor air, methods developed for the workplace and for ambient air are included since they should be adaptable to indoor air. Known and suspected carcinogens have been grouped into six categories for the purposes of this and related work. The categories are radon, asbestos, organic compounds, inorganic species, particles, and non-ionizing radiation. Some methods of assessing exposure that are not specific to any particular pollutant category are covered in a separate section. The report is the fifth in a series of EPA/Environmental Criteria and Assessment Office Monographs

  14. Assessment of the biomass related indoor air pollution in Kwale ...

    African Journals Online (AJOL)

    Background: Indoor air pollution remains an important health problem in some countries. Although research data on this issue is available, routine monitoring in affected areas is limited. The aims of this study were to quantify exposure to biomass- related indoor air pollution; assess the respiratory health of subjects; and ...

  15. Comfort Indicators for the Assessment of Indoor Environmental Building Performance

    DEFF Research Database (Denmark)

    Brohus, Henrik; Bendtsen, A.; Sørensen, M.

    2006-01-01

    Indoor environmental building performance assessment requires efficient indicators of the indoor comfort. In order to be effective and useful the comfort indicators must be able to include the temporal variation of indoor comfort as well as the degree of discomfort perceived by the occupants....... This paper discusses and presents a number of comfort indicators that includes both the temporal variation and the degree of discomfort in the calculations. A test case comprising a ventilated office building is used to show the application of the various comfort indices. It is found that the new comfort...

  16. Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose

    Science.gov (United States)

    Hussein, Tareq; Wierzbicka, Aneta; Löndahl, Jakob; Lazaridis, Mihalis; Hänninen, Otto

    2015-04-01

    Air pollution is one of the major environmental problems that influence people's health. Exposure to harmful particulate matter (PM) occurs both outdoors and indoors, but while people spend most of their time indoors, the indoor exposures tend to dominate. Moreover, higher PM concentrations due to indoor sources and tightness of indoor environments may substantially add to the outdoor originating exposures. Empirical and real-time assessment of human exposure is often impossible; therefore, indoor aerosol modeling (IAM) can be used as a superior method in exposure and health effects studies. This paper presents a simple approach in combining available aerosol-based modeling techniques to evaluate the real-time exposure and respiratory tract deposited dose based on particle size. Our simple approach consists of outdoor aerosol data base, IAM simulations, time-activity pattern data-base, physical-chemical properties of inhaled aerosols, and semi-empirical deposition fraction of aerosols in the respiratory tract. These modeling techniques allow the characterization of regional deposited dose in any metric: particle mass, particle number, and surface area. The first part of this presentation reviews recent advances in simple mass-balance based modeling methods that are needed in analyzing the health relevance of indoor exposures. The second part illustrates the use of IAM in the calculations of exposure and deposited dose. Contrary to previous methods, the approach presented is a real-time approach and it goes beyond the exposure assessment to provide the required information for the health risk assessment, which is the respiratory tract deposited dose. This simplified approach is foreseen to support epidemiological studies focusing on exposures originating from both indoor and outdoor sources.

  17. Links Related to the Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  18. School Indoor Air Quality Assessment and Program Implementation.

    Science.gov (United States)

    Prill, R.; Blake, D.; Hales, D.

    This paper describes the effectiveness of a three-step indoor air quality (IAQ) program implemented by 156 schools in the states of Washington and Idaho during the 2000-2001 school year. An experienced IAQ/building science specialist conducted walk-through assessments at each school. These assessments documented deficiencies and served as an…

  19. Introduction to the risk assessment workshop on indoor air quality

    International Nuclear Information System (INIS)

    Oezkaynak, H.; Spengler, J.D.

    1990-01-01

    Due to the emerging importance of the indoor air-quality problem and associated health risk concerns, on December 6-8, 1988 a three-day workshop on indoor air-quality risk assessment was jointly organized by Harvard University, Energy and Environmental Policy Center, and the Harvard School of Public Health. This introduction briefly summarizes the objectives of the workshop and its agenda. The workshop consisted of presentations and discussions by researchers from academic, government, and private institutions. Among the participants were those who have been involved in the design of major field studies of human exposure, physicians and toxicologists involved in clinical studies, human exposure modelers, and epidemiologists and health risk assessors. The overall objective of the workshop was to examine the critical elements needed to perform risk assessments on major indoor air pollutants. Eight pollutants were chosen for discussion: environmental tobacco smoke, formaldehyde, radon, volatile organic compounds, biologicals, man-made mineral fibers, nitrogen dioxide, and semivolatile organic compounds. Twenty-two papers were presented in the workshop. Eight of these papers are published in this issue of Risk Analysis. Nine of the remaining fourteen will shortly be published in the 'Exposure Assessment Section' issue of the Journal of Toxicology and Industrial Health

  20. BRIDGING OUTDOOR AND INDOOR ENVIRONMENTAL SIMULATION FOR ASSESSING AND AIDING SUSTAINABLE URBAN NEIGHBOURHOOD DESIGN

    Directory of Open Access Journals (Sweden)

    Chengzhi Peng

    2012-11-01

    Full Text Available Urban dwellers in cities located in hot-arid or hothumid regions have greater needs to live in between outdoor and indoor environments. The sustainability of urban building design in these regions cannot be fully assessed by indoor environmental simulation not taking into account the microclimatic factors of the surrounding urban neighbourhood. We find that the current suites of outdoor and indoor simulation software do not connect with each other to give us a holistic understanding of both outdoor and indoor simulation results. This paper reports on our current development of a methodological framework for bridging the current gap between outdoor and indoor environmental simulation. Our objective is that assessment of sustainability at an urban neighbourhood level can be carried out more holistically, and hence achieving more valid environmental simulations from an urban  dwelling point of view. The outdoor-indoor coupling methodology is currently modelled on a digital work flow among three key software platforms: (1 ENVImet for urban neighbourhood outdoor simulation, (2 Ecotect for building indoor simulation, (3 uCampus for combined outdoor-indoor 3D visualisation modelling of an entire urban neighbourhood including its individual buildings. A case study of a new neighbourhood development proposed for New Cairo is presented to demonstrate how indoor environmental simulation can be grounded on outdoor environmental simulation of the urban neighbourhood. Graphical outputs from this outdoorindoor coupling approach to neighbourhood simulation can be further brought together onto a Web-based 3D virtual reality modelling platform to enable wider accessibility.

  1. Quantitative assessments of indoor air pollution and the risk of childhood acute leukemia in Shanghai

    International Nuclear Information System (INIS)

    Gao, Yu; Zhang, Yan; Kamijima, Michihiro; Sakai, Kiyoshi; Khalequzzaman, Md; Nakajima, Tamie; Shi, Rong; Wang, Xiaojin; Chen, Didi; Ji, Xiaofan; Han, Kaiyi; Tian, Ying

    2014-01-01

    We investigated the association between indoor air pollutants and childhood acute leukemia (AL). A total of 105 newly diagnosed cases and 105 1:1 gender-, age-, and hospital-matched controls were included. Measurements of indoor pollutants (including nitrogen dioxide (NO 2 ) and 17 types of volatile organic compounds (VOCs)) were taken with diffusive samplers for 64 pairs of cases and controls. Higher concentrations of NO 2 and almost half of VOCs were observed in the cases than in the controls and were associated with the increased risk of childhood AL. The use of synthetic materials for wall decoration and furniture in bedroom was related to the risk of childhood AL. Renovating the house in the last 5 years, changing furniture in the last 5 years, closing the doors and windows overnight in the winter and/or summer, paternal smoking history and outdoor pollutants affected VOC concentrations. Our results support the association between childhood AL and indoor air pollution. - Highlights: • We firstly assessed the effects of indoor air pollution on childhood AL in China. • Indoor air pollutants were assessed by questionnaire and quantitative measurements. • NO 2 and 17 types of VOCs were measured in bedrooms of both cases and controls. • Higher concentrations of indoor air pollutants increased the risk of childhood AL. • Indoor behavioral factors and outdoor pollution might affect indoor air pollution. - Higher concentrations of indoor air pollutants were related to an elevated risk of childhood AL

  2. Assessment of the impact of oxidation processes on indoor air pollution using the new time-resolved INCA-Indoor model

    Science.gov (United States)

    Mendez, Maxence; Blond, Nadège; Blondeau, Patrice; Schoemaecker, Coralie; Hauglustaine, Didier A.

    2015-12-01

    INCA-Indoor, a new indoor air quality (IAQ) model, has been developed to simulate the concentrations of volatile organic compounds (VOC) and oxidants considering indoor air specific processes such as: emission, ventilation, surface interactions (sorption, deposition, uptake). Based on the detailed version of SAPRC-07 chemical mechanism, INCA-Indoor is able to analyze the contribution of the production and loss pathways of key chemical species (VOCs, oxidants, radical species). The potential of this model has been tested through three complementary analyses: a comparison with the most detailed IAQ model found in the literature, focusing on oxidant species; realistic scenarios covering a large range of conditions, involving variable OH sources like HONO; and the investigation of alkenes ozonolysis under a large range of indoor conditions that can increase OH and HO2 concentrations. Simulations have been run changing nitrous acid (HONO) concentrations, NOx levels, photolysis rates and ventilation rates, showing that HONO can be the main source of indoor OH. Cleaning events using products containing D-limonene have been simulated at different periods of the day. These scenarios show that HOX concentrations can significantly increase in specific conditions. An assessment of the impact of indoor chemistry on the potential formation of secondary species such as formaldehyde (HCHO) and acetaldehyde (CH3CHO) has been carried out under various room configuration scenarios and a study of the HOx budget for different realistic scenarios has been performed. It has been shown that, under the simulation conditions, formaldehyde can be affected by oxidant concentrations via chemical production which can account for more than 10% of the total production, representing 6.5 ppb/h. On the other hand, acetaldehyde production is affected more by oxidation processes. When the photolysis rates are high, chemical processes are responsible for about 50% of the total production of

  3. Life-cycle assessment framework for indoor emissions of synthetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Tobias, E-mail: tobias.walser@bag.admin.ch [ETH Zurich, Institute for Environmental Engineering (Switzerland); Meyer, David [U.S. Environmental Protection Agency, National Risk Management Research Laboratory (United States); Fransman, Wouter; Buist, Harrie; Kuijpers, Eelco; Brouwer, Derk [TNO (Netherlands)

    2015-06-15

    Life-Cycle Assessment (LCA) is a well-established method to evaluate impacts of chemicals on the environment and human health along the lifespan of products. However, the increasingly produced and applied nanomaterials (defined as one dimension <100 nm) show particular characteristics which are different from conventional chemicals or larger particles. As a consequence, LCA does not provide sufficient guidance on how to deal with synthetic nanomaterials, neither in the exposure, nor in the effect assessment. This is particularly true for the workplace, where significant exposure can be expected via the lung, the route of major concern. Therefore, we developed a concise method which allows the inclusion of indoor nanoparticle exposure into LCA. New nanospecific properties are included along the LCA stages with a particular focus on the workplace environment. We built upon existing LCA methods and nanoparticle fate and exposure studies. The impact assessment requires new approaches for nanoparticles, such as guidance on relevant endpoints, nanospecific properties that are relevant for the toxicity, and guidance on the chemical identity of nanomaterials, i.e., categorization and distinction of different forms of nanomaterials. We present a framework which goes beyond traditional approaches of LCA and includes nanospecific fate parameters in the indoor exposure assessment as well as guidance on the development of effect and characterization factors for inhaled nanoparticles. Specifically, the indoor one-box model is amended with new particle-specific parameters developed in the exposure literature. A concentration conversion and parameter estimation tool are presented. Finally, the modification of the traditional intake fraction to capture size-specific deposition and retention rate are discussed along with a strategy for a more robust effect assessment. The paper is a further step toward a fair comparison between conventional and nano-enabled products by integrating

  4. Life-cycle assessment framework for indoor emissions of synthetic nanoparticles

    Science.gov (United States)

    Walser, Tobias; Meyer, David; Fransman, Wouter; Buist, Harrie; Kuijpers, Eelco; Brouwer, Derk

    2015-06-01

    Life-Cycle Assessment (LCA) is a well-established method to evaluate impacts of chemicals on the environment and human health along the lifespan of products. However, the increasingly produced and applied nanomaterials (defined as one dimension chemicals or larger particles. As a consequence, LCA does not provide sufficient guidance on how to deal with synthetic nanomaterials, neither in the exposure, nor in the effect assessment. This is particularly true for the workplace, where significant exposure can be expected via the lung, the route of major concern. Therefore, we developed a concise method which allows the inclusion of indoor nanoparticle exposure into LCA. New nanospecific properties are included along the LCA stages with a particular focus on the workplace environment. We built upon existing LCA methods and nanoparticle fate and exposure studies. The impact assessment requires new approaches for nanoparticles, such as guidance on relevant endpoints, nanospecific properties that are relevant for the toxicity, and guidance on the chemical identity of nanomaterials, i.e., categorization and distinction of different forms of nanomaterials. We present a framework which goes beyond traditional approaches of LCA and includes nanospecific fate parameters in the indoor exposure assessment as well as guidance on the development of effect and characterization factors for inhaled nanoparticles. Specifically, the indoor one-box model is amended with new particle-specific parameters developed in the exposure literature. A concentration conversion and parameter estimation tool are presented. Finally, the modification of the traditional intake fraction to capture size-specific deposition and retention rate are discussed along with a strategy for a more robust effect assessment. The paper is a further step toward a fair comparison between conventional and nano-enabled products by integrating occupational exposure to synthetic nanomaterials into LCA.

  5. Life-cycle assessment framework for indoor emissions of synthetic nanoparticles

    International Nuclear Information System (INIS)

    Walser, Tobias; Meyer, David; Fransman, Wouter; Buist, Harrie; Kuijpers, Eelco; Brouwer, Derk

    2015-01-01

    Life-Cycle Assessment (LCA) is a well-established method to evaluate impacts of chemicals on the environment and human health along the lifespan of products. However, the increasingly produced and applied nanomaterials (defined as one dimension <100 nm) show particular characteristics which are different from conventional chemicals or larger particles. As a consequence, LCA does not provide sufficient guidance on how to deal with synthetic nanomaterials, neither in the exposure, nor in the effect assessment. This is particularly true for the workplace, where significant exposure can be expected via the lung, the route of major concern. Therefore, we developed a concise method which allows the inclusion of indoor nanoparticle exposure into LCA. New nanospecific properties are included along the LCA stages with a particular focus on the workplace environment. We built upon existing LCA methods and nanoparticle fate and exposure studies. The impact assessment requires new approaches for nanoparticles, such as guidance on relevant endpoints, nanospecific properties that are relevant for the toxicity, and guidance on the chemical identity of nanomaterials, i.e., categorization and distinction of different forms of nanomaterials. We present a framework which goes beyond traditional approaches of LCA and includes nanospecific fate parameters in the indoor exposure assessment as well as guidance on the development of effect and characterization factors for inhaled nanoparticles. Specifically, the indoor one-box model is amended with new particle-specific parameters developed in the exposure literature. A concentration conversion and parameter estimation tool are presented. Finally, the modification of the traditional intake fraction to capture size-specific deposition and retention rate are discussed along with a strategy for a more robust effect assessment. The paper is a further step toward a fair comparison between conventional and nano-enabled products by integrating

  6. Indoor air quality in the Greater Beirut area: a characterization and modeling assessment

    International Nuclear Information System (INIS)

    El-Fadel, Mutasem; El-Hougeiri, Nisrine; Oulabi, Mawiya

    2003-01-01

    This report presents the assessment of IAQ at various environments selected from different geographic categories from the Greater Beirut area (GBA) in Lebanon. For this purpose, background information about indoor air quality was reviewed, existing conditions were characterized, an air-sampling program was implemented and mathematical modeling was conducted. Twenty-eight indoor buildings were selected from various geographic categories representing different environments (commercial and residential...). Indoor and outdoor air samples were collected and analyzed using carbon monoxide (CO), particulate matter (TSP), nitrogen dioxide (NO 2 ) and total volatile organic compounds (TVOC) as indicators of indoor air pollution (IAP).Samples were further analyzed using the energy dispersive x-ray fluorescence technique (EDXRF) for the presence of major priority metals including iron (Fe), calcium (Ca), zinc (Zn), lead (Pb), manganese (Mn), copper (Cu) and bromine (Br). Indoor and outdoor measured levels were compared to the American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE) and health-based National Ambient Air Quality standards (NAAQS), respectively. For the priority metals, on the other hand, indoor measured values were compared to occupational standards recommended by the National Institute of Occupational Safety and Health (NIOSH) and Occupational Safety and Health Administration (OSHA)

  7. An indoor air quality assessment for vulnerable populations exposed to volcanic vog from Kilauea Volcano.

    Science.gov (United States)

    Longo, Bernadette M; Yang, Wei; Green, Joshua B; Longo, Anthony A; Harris, Merylin; Bibilone, Renwick

    2010-01-01

    The Ka'u District of Hawaii is exposed to sulfurous air pollution called vog from the ongoing eruption of Kilauea Volcano. Increased volcanic activity in 2008 prompted an indoor air quality assessment of the district's hospital and schools. All indoor sulfur dioxide concentrations were above the World Health Organization's average 24-hour recommendation. Indoor penetration ratios were up to 94% of ambient levels and dependent upon building construction or the use of air-conditioning. Health-promotion efforts for vulnerable populations at the hospital and schools are under way to improve indoor air quality and respond to those affected by vog exposure.

  8. Indoor Air Quality Assessment of Elementary Schools in Curitiba, Brazil

    International Nuclear Information System (INIS)

    Godoi, R. H. M.; Avigo, D.; Campos, V. P.; Tavares, T. M.; Marchi, M. R. R. de; Grieken, R. Van; Godoi, A. F. L.

    2009-01-01

    The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO 2 ; SO 2 ; O 3 ; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatography-ion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO 2 varied between 9.5 and 23 μg m -3 , whereas SO 2 showed an interval from 0.1 to 4.8 μg m -3 . Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5 μg m -3 and 1.2 μg m -3 , respectively.

  9. Assessment of volatile organic compound removal by indoor plants-a novel experimental setup

    DEFF Research Database (Denmark)

    Dela Cruz, Majbrit; Müller, Renate; Svensmark, Bo

    2014-01-01

    plants which allows for an improved real-life simulation. Parameters such as relative humidity, air exchange rate and VOC concentration are controlled and can be varied to simulate different real-life settings. For example, toluene diffusion through a needle gave concentrations in the range of 0......Indoor plants can remove volatile organic compounds (VOCs) from the air. The majority of knowledge comes from laboratory studies where results cannot directly be transferred to real-life settings. The aim of this study was to develop an experimental test system to assess VOC removal by indoor.......10-2.35 μg/L with deviations from theoretical values of 3.2-10.5 %. Overall, the system proved to be functional for the assessment of VOC removal by indoor plants with Hedera helix reaching a toluene removal rate of up to 66.5 μg/m2/h. The mode of toluene exposure (semi-dynamic or dynamic) had a significant...

  10. Assessment of Thailand indoor set-point impact on energy consumption and environment

    International Nuclear Information System (INIS)

    Yamtraipat, N.; Khedari, J.; Hirunlabh, J.; Kunchornrat, J.

    2006-01-01

    The paper presents an investigation of indoor set-point standard of air-conditioned spaces as a tool to control electrical energy consumption of air-conditioners in Thailand office buildings and to reduce air pollutants. One hundred and forty-seven air-conditioned rooms in 13 buildings nationwide were used as models to analyze the electricity consumption of air-conditioning systems according to their set indoor temperatures, which were below the standard set-point and were accounted into a large scale. Then, the electrical energy and environmental saving potentials in the country were assessed by the assumption that adaptation of indoor set-point temperature is increased up to the standard set-point of 26 o C. It was concluded that the impacts of indoor set-point of air-conditioned rooms, set at 26 o C, on energy saving and on environment are as follows: The overall electricity consumption saving would be 804.60 GWh/year, which would reduce the corresponding GHGs emissions (mainly CO 2 ) from power plant by 579.31x10 3 tons/year

  11. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  12. Microbiological assessment of indoor air of teaching hospital wards ...

    African Journals Online (AJOL)

    Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. METHODS: The microbial quality of indoor air of seven wards of Jimma University ...

  13. Microbiological assessment of indoor air quality at different hospital sites.

    Science.gov (United States)

    Cabo Verde, Sandra; Almeida, Susana Marta; Matos, João; Guerreiro, Duarte; Meneses, Marcia; Faria, Tiago; Botelho, Daniel; Santos, Mateus; Viegas, Carla

    2015-09-01

    Poor hospital indoor air quality (IAQ) may lead to hospital-acquired infections, sick hospital syndrome and various occupational hazards. Air-control measures are crucial for reducing dissemination of airborne biological particles in hospitals. The objective of this study was to perform a survey of bioaerosol quality in different sites in a Portuguese Hospital, namely the operating theater (OT), the emergency service (ES) and the surgical ward (SW). Aerobic mesophilic bacterial counts (BCs) and fungal load (FL) were assessed by impaction directly onto tryptic soy agar and malt extract agar supplemented with antibiotic chloramphenicol (0.05%) plates, respectively using a MAS-100 air sampler. The ES revealed the highest airborne microbial concentrations (BC range 240-736 CFU/m(3) CFU/m(3); FL range 27-933 CFU/m(3)), exceeding, at several sampling sites, conformity criteria defined in national legislation [6]. Bacterial concentrations in the SW (BC range 99-495 CFU/m(3)) and the OT (BC range 12-170 CFU/m(3)) were under recommended criteria. While fungal levels were below 1 CFU/m(3) in the OT, in the SW (range 1-32 CFU/m(3)), there existed a site with fungal indoor concentrations higher than those detected outdoors. Airborne Gram-positive cocci were the most frequent phenotype (88%) detected from the measured bacterial population in all indoor environments. Staphylococcus (51%) and Micrococcus (37%) were dominant among the bacterial genera identified in the present study. Concerning indoor fungal characterization, the prevalent genera were Penicillium (41%) and Aspergillus (24%). Regular monitoring is essential for assessing air control efficiency and for detecting irregular introduction of airborne particles via clothing of visitors and medical staff or carriage by personal and medical materials. Furthermore, microbiological survey data should be used to clearly define specific air quality guidelines for controlled environments in hospital settings. Copyright

  14. Assessing indoor air quality options: Final environmental impact statement on new energy-efficient home programs: Volume 2

    International Nuclear Information System (INIS)

    1988-03-01

    This report discusses the impact of energy conservation measures on indoor air quality in various size residential buildings. This volume includes appendices on ventilation rates, indoor pollutant levels, health effects, human risk assessment, radon, fiberglass hazards, tobacco smoke, mitigation

  15. THE ASSESSMENT OF MICROBIOLOGICAL INDOOR AIR QUALITY IN BAKERIES

    Directory of Open Access Journals (Sweden)

    Elżbieta Wołejko

    2016-05-01

    Full Text Available The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.

  16. A real-time monitoring and assessment method for calculation of total amounts of indoor air pollutants emitted in subway stations.

    Science.gov (United States)

    Oh, TaeSeok; Kim, MinJeong; Lim, JungJin; Kang, OnYu; Shetty, K Vidya; SankaraRao, B; Yoo, ChangKyoo; Park, Jae Hyung; Kim, Jeong Tai

    2012-05-01

    Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in

  17. Assessment of Indoor Radon (222Rn) Concentrations in the Vicinity of

    African Journals Online (AJOL)

    MLAY

    ABSTRACT. This study aimed to assess indoor radon concentrations in the vicinity of the Manyoni Uranium ... risk of lung cancer proportionally to the ... deposit, power plant, industrial radiation, etc. ... in foundations, walls, hollow concrete .... (AlphaGUARD User Manual 2007). ... used as control are presented in Table 4. The.

  18. Assessing future trends in indoor air quality

    International Nuclear Information System (INIS)

    van de Wiel, H.J.; Lebret, E.; van der Lingen, W.K.; Eerens, H.C.; Vaas, L.H.; Leupen, M.J.

    1990-01-01

    Several national and international health organizations have derived concentration levels below which adverse effects on men are not expected or levels below which the excess risk for individuals is less than a specified value. For every priority pollutant indoor concentrations below this limit are considered healthy. The percentage of Dutch homes exceeding such a limit is taken as a measure of indoor air quality for that component. The present and future indoor air quality of the Dutch housing stock is described for fourteen air pollutants. The highest percentages are scored by radon, environmental tobacco smoke, nitrogen dioxide from unvented combustion, and the potential presence of housedust mite and mould allergen in damp houses. Although the trend for all priority pollutants is downward the most serious ones remain high in the coming decades if no additional measures will be instituted

  19. Procedure for the characterization of radon potential in existing dwellings and to assess the annual average indoor radon concentration

    International Nuclear Information System (INIS)

    Collignan, Bernard; Powaga, Emilie

    2014-01-01

    Risk assessment due to radon exposure indoors is based on annual average indoor radon activity concentration. To assess the radon exposure in a building, measurement is generally performed during at least two months during heating period in order to be representative of the annual average value. This is because radon presence indoors could be very variable during time. This measurement protocol is fairly reliable but may be a limiting in the radon risk management, particularly during a real estate transaction due to the duration of the measurement and the limitation of the measurement period. A previous field study defined a rapid methodology to characterize radon entry in dwellings. The objective of this study was at first, to test this methodology in various dwellings to assess its relevance with a daily test. At second, a ventilation model was used to assess numerically the air renewal of a building, the indoor air quality all along the year and the annual average indoor radon activity concentration, based on local meteorological conditions, some building characteristics and in-situ characterization of indoor pollutant emission laws. Experimental results obtained on thirteen individual dwellings showed that it is generally possible to obtain a representative characterization of radon entry into homes. It was also possible to refine the methodology defined in the previous study. In addition, numerical assessments of annual average indoor radon activity concentration showed generally a good agreement with measured values. These results are encouraging to allow a procedure with a short measurement time to be used to characterize long-term radon potential in dwellings. - Highlights: • Test of a daily procedure to characterize radon potential in dwellings. • Numerical assessment of the annual radon concentration. • Procedure applied on thirteen dwellings, characterization generally satisfactory. • Procedure useful to manage radon risk in dwellings, for real

  20. Assessing indoor air quality in New York City nail salons.

    Science.gov (United States)

    Pavilonis, Brian; Roelofs, Cora; Blair, Carly

    2018-05-01

    Nail salons are an important business and employment sector for recent immigrants offering popular services to a diverse range of customers across the United States. However, due to the nature of nail products and services, salon air can be burdened with a mix of low levels of hazardous airborne contaminants. Surveys of nail technicians have commonly found increased work-related symptoms, such as headaches and respiratory irritation, that are consistent with indoor air quality problems. In an effort to improve indoor air quality in nail salons, the state of New York recently promulgated regulations to require increased outdoor air and "source capture" of contaminants. Existing indoor air quality in New York State salons is unknown. In advance of the full implementation of the rules by 2021, we sought to establish reliable and usable baseline indoor air quality metrics to determine the feasibility and effectiveness of the requirement. In this pilot study, we measured total volatile organic compounds (TVOC) and carbon dioxide (CO 2 ) concentrations in 10 nail salons located in New York City to assess temporal and spatial trends. Within salon contaminant variation was generally minimal, indicating a well-mixed room and similar general exposure despite the task being performed. TVOC and CO 2 concentrations were strongly positively correlated (ρ = 0.81; p air quality for the purposes of compliance with the standard. An almost tenfold increase in TVOC concentration was observed when the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE) target CO 2 concentration of 850 ppm was exceeded compared to when this target was met.

  1. Development of an indoor air quality checklist for risk assessment of indoor air pollutants by semiquantitative score in nonindustrial workplaces

    Directory of Open Access Journals (Sweden)

    Syazwan AI

    2012-04-01

    Full Text Available AI Syazwan1, B Mohd Rafee1, Juahir Hafizan2, AZF Azman1, AM Nizar3, Z Izwyn4, AA Muhaimin5, MA Syafiq Yunos6, AR Anita1, J Muhamad Hanafiah1, MS Shaharuddin1, A Mohd Ibthisham7, Mohd Hasmadi Ismail8, MN Mohamad Azhar1, HS Azizan1, I Zulfadhli9, J Othman101Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, Malaysia; 2Department of Environmental Science, Faculty of Environmental Studies, Universiti Putra Malaysia, Selangor, Malaysia; 3Pharmacology Unit, Department of Human Anatomy, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, Malaysia; 4Department of Therapy and Rehabilitation, Faculty of Health Science and Biomedical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia; 5Department of Environmental Management, Faculty of Environmental Studies, Universiti Putra Malaysia, Selangor, Malaysia; 6Plant Assessment Technology (PAT, Industrial Technology Division (BTI, Malaysian Nuclear Agency (Nuklear Malaysia, Bangi, Kajang, Malaysia; 7Department of Mechanical Engineering, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, UTM Skudai, Johor, Malaysia; 8Department of Forest Production, Faculty of Forestry, Universiti Putra Malaysia, Selangor, Malaysia; 9Faculty of Built Environment and Architect, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia; 10Department of Counsellor Education and Counselling Psychology (DCECP, Faculty of Educational Studies, Universiti Putra Malaysia, Selangor, MalaysiaBackground: To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ component of a participatory occupational safety and health survey should be included.Objectives: The purpose of this study was to evaluate and suggest a multidisciplinary, integrated IAQ checklist for evaluating the health risk of building occupants. This IAQ checklist proposed to support

  2. Impact of whole-building hygrothermal modelling on the assessment of indoor climate in a library building

    Energy Technology Data Exchange (ETDEWEB)

    Steeman, M.; Janssens, A. [Ghent University, Department of Architecture and Urban Planning, Jozef Plateaustraat 22, B-9000 Gent (Belgium); De Paepe, M. [Ghent University, Department of Flow, Heat and Combustion Mechanics, Sint-Pietersnieuwstraat 41, B-9000 Gent (Belgium)

    2010-07-15

    This paper focuses on the importance of accurately modelling the hygrothermal interaction between the building and its hygroscopic content for the assessment of the indoor climate. Libraries contain a large amount of stored books which require a stable relative humidity to guarantee their preservation. On the other hand, visitors and staff must be comfortable with the indoor climate. The indoor climate of a new library building is evaluated by means of measurements and simulations. Complaints of the staff are confirmed by measured data during the winter and summer of 2007-2008. For the evaluation of the indoor climate, a building simulation model is used in which the porous books are either described by a HAM model or by a simplified isothermal model. Calculations demonstrate that the HAM model predicts a more stable indoor climate regarding both temperature and relative humidity variations in comparison to the estimations by the simplified model. This is attributed to the ability of the HAM model to account for the effect of temperature variations on moisture storage. Moreover, by applying the HAM model, a good agreement with the measured indoor climate is found. As expected, a larger exposed book surface ameliorates the indoor climate because a more stable indoor relative humidity is obtained. Finally, the building simulation model is used to improve the indoor climate with respect to the preservation of valuable books. Results demonstrate that more stringent interventions on the air handling unit are expected when a simplified approach is used to model the hygroscopic books. (author)

  3. Breathing thermal manikin for indoor environment assessment: Important characteristics and requirements

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2003-01-01

    Recently breathing thermal manikins have been developed and used for indoor environment measurement, evaluation and optimization as well as validation of Computational Fluid Dynamics (CFD) predictions of airflow around a human body. Advances in the assessment of occupants¿ thermal comfort...... and shape of body segments, control mode, breathing simulation, etc. are discussed and specified in this paper....

  4. Health effects from indoor and outdoor exposure to fine particulate matter in life cycle impact assessment

    DEFF Research Database (Denmark)

    Fantke, Peter; McKone, T.E.; Jolliet, Olivier

    2016-01-01

    Exposure to fine particulate matter (PM2.5) pollution is a major contributor to human disease burden as continuously shown in the Global Burden of Disease study series. Exposures to PM2.5 concentration outdoors and indoors contribute almost equally to this burden. Despite the importance, health...... impacts from exposure to PM2.5 are often excluded from life cycle impact assessment (LCIA) characterization profiles. This is in large part because of the lack of well-vetted harmonized guidance about how to consistently assess the exposures and impacts of indoor and outdoor emissions of PM2.5 and its...... precursors. We present a framework for calculating characterization factors for indoor and outdoor emissions of primary PM2.5 and secondary PM2.5 precursors, and a roadmap for further refining this modelling framework for operational use in LCIA. The framework was developed over the last three years...

  5. Specification of indoor climate design parameters at the assessment of moisture protective properties of enclosing structures

    Directory of Open Access Journals (Sweden)

    Kornienko Sergey Valer’evich

    2016-11-01

    Full Text Available Due to wide implementation of enveloping structures with increased heat-insulation properties in modern construction here appeared a necessity to assess their moisture conditions. Assessment of moisture conditions of enveloping structures is carried out according to maximum allowable moisture state basing on determining the surface of maximum damping. In relation to it the necessity of additional vapour barrier is checked using moisture balance equation. Though the change of indoor climate parameters in premises is not taken into account in moisture balance equations defined for different seasons. The author improves the method of calculating moisture protective parameters of enclosing structures according to the maximum allowable damping state for a year and a period of moisture accumulation. It is shown in this article that accounting of temperature and relative humidity change of inside air allows specifying calculated parameters of indoor climate in residential and office rooms in assessment of moisture protective properties of enclosing structures for the case of an effective enclosing structure with a façade heat-insulation composite system. Coordinates of the maximum moistened surface of the envelope depends on indoor climate design parameters. It is concluded that the increase of requirements for moisture protection of enclosing structures when using design values of temperature and relative humidity of internal air according to the Russian regulation (SP 50.13330.2012 is not always reasonable. Accounting of changes of indoor climate parameters allows more precise assessment of moisture protective properties of enclosing structures during their design.

  6. The impact of a photocatalytic paint on indoor air pollutants: Sensory assessments

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn

    2012-01-01

    was illuminated by bulbs emitting visible/UV light. A mixture of common indoor pollutants, including emissions from chipboard, linoleum and carpet, as well as human bioffluents and isopropanol, were used to test the efficacy of the paint. A sensory panel of 35 subjects assessed the air quality in the test...

  7. Emission of ammonia from indoor concrete wall and assessment of human exposure.

    Science.gov (United States)

    Bai, Z; Dong, Y; Wang, Z; Zhu, T

    2006-04-01

    Addition of urea-based antifreeze admixtures during cement mixing can make it possible to produce concrete cement in construction of buildings in cold weather; this, however, has led to increasing indoor air pollution due to continuous transformation and emission from urea to gaseous ammonia in indoor concrete wall. It is believed that ammonia is harmful to human body and exposure to ammonia can cause some serious symptoms such as headaches, burns, and even permanent damage to the eyes and lungs. In order to understand the emission of ammonia from indoor concrete wall in civil building and assess the health risk of people living in these buildings, the experimental pieces of concrete wall were first prepared by concreting cement and urea-based antifreeze admixtures to simulate the indoor wall in civil building in this work. Then environmental chamber was adopted for studying the effect of temperature, relative humility and air exchange rate on emission of ammonia from experimental pieces of concrete wall. Also the field experiment was made at selected rooms in given civil buildings. Exposure and potential dose of adult and children exposed to indoor/outdoor ammonia in summer and in winter are calculated and evaluated by using Scenario Evaluation Approach. The results indicated that high air exchange rate leads to decreased ammonia concentration, and elevation of temperature causes increasing ammonia concentration and volatilizing rate in chamber. The complete emission of ammonia from the wall containing urea-based antifreeze admixtures needs more than 10 years in general. Ventilating or improving air exchange can play a significant role in reducing ammonia concentration in actual rooms in field experiments. Urea-based antifreeze admixtures in concrete wall can give rise to high exposure and potential dose, especially in summer. Generally, adults have a high potential dose than children, while children have personal average dose rate beyond adults in the same

  8. The ORNL Indoor Air Quality Study: Re-cap, Context, and Assessment on Radon

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, Bruce Edward [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rose, Erin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ternes, Mark P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-10-01

    As part of the retrospective evaluation of the U.S. Department of Energy s low-income Weatherization Assistance Program that was led by Oak Ridge National Laboratory (ORNL), an assessment of the impacts of weatherization on indoor air quality (IAQ) was conducted. This assessment included nearly 500 treatment and control homes across the country. Homes were monitored for carbon monoxide, radon, formaldehyde, temperature and humidity pre- and post-weatherization. This report focuses on the topic of radon and addresses issues not thoroughly discussed in the original IAQ report. The size, scope and rigor of the radon component of the IAQ study are compared to previous studies that assessed the impacts of weatherization on indoor radon levels. It is found that the ORNL study is by far the most extensive study conducted to date, though the ORNL results are consistent with the findings of the other studies. However, the study does have limitations related to its reliance on short-term measurements of radon and inability to attribute changes in radon levels in homes post-weatherization to specific weatherization measures individually or in combination.

  9. Indoor radon II

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Because of the growing interest in and public concern about indoor radon, APCA, in April 1987, sponsored the Second International Specialty Conference on Indoor Radon. This book is the proceedings of this conference and includes discussions on: A current assessment of the nature of the problem; Issues related to health effects and risk assessment; The development of public and private sector initiatives; Research into methods of control and prevention; International perspectives; and Measurement methods and programs. The material is intended for the technically oriented and for those responsible for developing programs and initiatives to address this important public health issue. Contributors include federal, state, and provincial program officials and members of the academic and private sectors

  10. An assessment of indoor radon exposure in Ireland

    International Nuclear Information System (INIS)

    McLaughlin, J.P.

    1987-01-01

    The results of measurements of indoor radon in over 700 dwellings chosen at ''random'' throughout the Republic of Ireland are presented. The median value of radon in these dwellings was found to be 37 Bq/m 3 (1 pCi/1). The distribution of indoor radon concentration appears to be approximately log-normal with about 2% of the dwellings surveyed having concentrations greater than 400 Bq/m 3 . High radon values were generally found to be more common in western and southern regions of the country than in the more densely populated eastern seabord. Using dose conversion factors in keeping with recent developments in lung dosimetry the median effective dose equivalent to occupants arising from the inhalation of radon daughters in the dwellings surveyed is estimated to be about 1.8 mSv per year. On the same basis for dwellings with indoor radon above 400 Bq/m 3 the continuous effective dose equivalent is estimated to be in excess of 20 mSv per year

  11. Children's exposure to indoor air in urban nurseries-part I: CO2 and comfort assessment

    International Nuclear Information System (INIS)

    Branco, P.T.B.S.; Alvim-Ferraz, M.C.M.; Martins, F.G.; Sousa, S.I.V.

    2015-01-01

    Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study “Children's exposure to indoor air in urban nurseries”, aimed to: i) evaluate nurseries’ indoor concentrations of carbon dioxide (CO 2 ), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters–temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO 2 concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. - Highlights: • High occupation and poor ventilation were main determinants of IAQ in nurseries. • T and RH indoor values found in nurseries are likely to cause thermal discomfort. • Building characteristics and an inadequate ventilation determined T and RH values. • High CO 2 concentrations found could indicate accumulation of other air pollutants

  12. Pilot study on indoor air quality: Managing indoor air-quality risks. Report on a meeting held in St. Michaels, Maryland on October 25-27, 1989

    International Nuclear Information System (INIS)

    1990-06-01

    Included in this study are the following: quantifying future trends of indoor air quality as a basis for government policy plans; assessing indoor air quality risks of pesticides; formaldehyde emission standards in the Federal Republic of Germany; orientations and actions of the European Community in the assessment and prevention of indoor air pollution; EPA and indoor air quality; the non-regulatory approach to reducing risks from radon exposure; U.S. consumer product safety commission; a builders guide to healthy homes; WHO air quality guidelines for Europe; the approach to control indoor air quality in Italy; guidelines - ventilation classes; energy consequences of upgrading indoor air quality; Canada's guidelines for residential indoor air quality: rationale and scope; Canadian ventilation and venting standards; indoor air quality building surveys case studies; design of indoor air quality studies; summary findings of inter-ministerial committee on indoor air quality (Ontario); the Quebec approach; employee survey EPA headquarters; pollution in closed spaces and its consequences in conservation of works of art; and how Norwegian health authorities will handle indoor air quality problems

  13. An indoor chemical cocktail

    Science.gov (United States)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  14. Influence of indoor formaldehyde pollution on respiratory system ...

    African Journals Online (AJOL)

    Background The decoration of interior spaces can lead to dangerous levels of indoor formaldehyde pollution. Exposure to indoor air pollution may be responsible for nearly 2 million deaths per year in developing countries. Objectives To assess the prevalence of indoor formaldehyde pollution caused by decoration and ...

  15. The effects of vegetation on indoor thermal comfort

    DEFF Research Database (Denmark)

    Pastore, Luisa; Corrao, Rossella; Heiselberg, Per Kvols

    2017-01-01

    Highlights •A multi-scale simulation methodology to assess the effects of vegetation on thermal comfort is used. •It application is shown on a case of urban and building retrofit intervention. •The effect of plants on the microclimate and indoor environment is assessed. •A decrease of up to 4.8 °C...... in indoor temperature is registered. •The final impact on the indoor thermal comfort based on the adaptive model is determined....

  16. Assessment of indoor radon gas concentration change of college

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul [Dept. of of Radiological Technology, Shingu College, Seongnam (Korea, Republic of); Lee, Ju Young [Dept. of Radiological Technology, Songho College, Hoengseong (Korea, Republic of)

    2017-03-15

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction.

  17. Assessment of indoor radon gas concentration change of college

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul; Lee, Ju Young

    2017-01-01

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction

  18. Assessment and predictor determination of indoor aldehyde levels in Paris newborn babies' homes.

    Science.gov (United States)

    Dassonville, C; Demattei, C; Laurent, A-M; Le Moullec, Y; Seta, N; Momas, I

    2009-08-01

    Exposure to indoor chemical air pollutants expected to be potentially involved in allergic respiratory diseases in infants is poorly documented. A specific environmental investigation included in a birth cohort study was carried out to first assess indoor airborne aldehyde levels, using passive devices and their variability within 1 year (1, 6, 9 and 12 months) in the bedroom of 196 Paris infants, and second, to identify predictors for aldehyde concentrations using interviewer administered questionnaires about housing factors. Comfort parameters and carbon dioxide levels were measured simultaneously. Aldehydes were detected in almost all dwellings and geometric mean levels (geometric standard deviation) at the first visit were respectively for formaldehyde, acetaldehyde, hexanal, and pentanal 19.4 (1.7) microg/m(3), 8.9 (1.8) microg/m(3), 25.3 (3.1) microg/m(3), 3.7 (2.3) microg/m(3), consistent with earlier published results. Generalized Estimating Equation multivariate analyses showed that, apart from comfort parameters, aeration and season, the main indoor aldehyde sources were either continuous (building materials and coverings especially when they were new) or discontinuous (smoking, use of air fresheners and cleaning products, DIY etc...). Finally, the data collected by questionnaires should be sufficient to enable us to classify each infant in our cohort study according to his/her degree of exposure to the main aldehydes. This analysis contributed to document indoor aldehyde levels in Parisian homes and to identify factors determining these levels. In the major part of newborn babies' homes, indoor formaldehyde levels were above the guideline value of 10 microg/m(3) proposed by the French Agency for Environmental and Occupational Health Safety for long-term exposure. Given this result, it is essential to study the health impact of exposure to aldehydes especially formaldehyde on the incidence of respiratory and allergic symptoms, particularly during the

  19. Indoor aerosols

    DEFF Research Database (Denmark)

    Morawska, L.; Afshari, Alireza; N. Bae, G.

    2013-01-01

    Motivated by growing considerations of the scale, severity, and risks associated with human exposure to indoor particulate matter, this work reviewed existing literature to: (i) identify state-of-the-art experimental techniques used for personal exposure assessment; (ii) compare exposure levels...

  20. Assessment of indoor environment in Paris child day care centers.

    Science.gov (United States)

    Roda, Célina; Barral, Sophie; Ravelomanantsoa, Hanitriniala; Dusséaux, Murielle; Tribout, Martin; Le Moullec, Yvon; Momas, Isabelle

    2011-11-01

    Children are sensitive to indoor environmental pollution. Up until now there has been a lack of data on air quality in child day care centers. The aim of this study is to document the indoor environment quality of Paris child day care centers by repeated measurements, and to compare pollutant levels in child day care centers with levels in Paris dwellings. We selected 28 child day care centers frequented by a random sample of babies who participated in the PARIS birth cohort environmental investigation, and visited the child day care centers for one week twice in one year. Biological contaminants assessed were fungi, endotoxin, dust mite allergens, and chemical pollutants: aldehydes, volatile organic compounds and nitrogen dioxide (NO2). Relative humidity, temperature, and carbon dioxide levels were measured simultaneously. A standardized questionnaire was used to gather information about the buildings and their inhabitants. Airborne endotoxin levels in child day care centers were higher than those found in Paris dwellings. Dust mite allergens in child day care centers were below the threshold level for sensitization in the majority of samples, and in common with dwelling samples. Penicillium and Cladosporium were the most commonly identified genera fungi. The child day care center indoor/outdoor ratio for most chemical pollutants was above unity except for NO2, the levels for NO2 being significantly higher than those measured in homes. Chemical and biological contamination in child day care centers appears to be low, apart from endotoxin and NO2. Failure to take child exposure in child day care centers into account could result in an overestimation of children's exposure to other pollutants. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. In search of the comfortable indoor environment: A comparison of the utility of objective and subjective indicators of indoor comfort

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, Niklas; Skoog, Jennie [Building Services Engineering, Department of Energy and Environment, Chalmers University of Technology, Gothenburg (Sweden); Vaestfjaell, Daniel [Department of Psychology, Goeteborg University (Sweden)

    2007-05-15

    Today, many procedures for assessing the indoor environment rely on both subjective and objective indicators (e.g. ANSI/ASHRAE 55-2004; ISO 10551). It is however unclear how these two types of measurements are related to perceived comfort. This article aims at assessing the relative utility of subjective (rating scale measures) and objective indicators of perceived comfort of indoor environments. In a hospital setting, physical environmental variables (e.g. temperature, relative humidity and noise level) were simultaneously measured as respondents (both patients and staff) rated their perception of the indoor environment. Regression analyses indicated that the subjective sensory ratings were significantly better than objective indicators at predicting overall rated indoor comfort. These results are discussed in relation to existing measurement procedures and standards. (author)

  2. Impact of indoor surface material on perceived air quality.

    Science.gov (United States)

    Senitkova, I

    2014-03-01

    The material combination impact on perceived indoor air quality for various surface interior materials is presented in this paper. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). In this study, emissions and odors from different common indoor surface materials were investigated in glass test chamber under standardized conditions. Chemical measurements (TVOC concentration) and sensory assessments (odor intensity, air acceptability) were done after building materials exposure to standardized conditions. The results of the chemical and sensory assessment of individual materials and their combinations are compared and discussed within the paper. The using possibility of individual material surface sorption ability was investigated. The knowledge of targeted sorption effects can be used in the interior design phase. The results demonstrate the various sorption abilities of various indoor materials as well as the various sorption abilities of the same indoor material in various combinations. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Assessing indoor air quality of school environments: transplanted lichen Pseudovernia furfuracea as a new tool for biomonitoring and bioaccumulation.

    Science.gov (United States)

    Protano, Carmela; Owczarek, Malgorzata; Antonucci, Arianna; Guidotti, Maurizio; Vitali, Matteo

    2017-07-01

    The aim of this research is to evaluate the ability of transplanted lichen Pseudovernia (P). furfuracea to biomonitor and bioaccumulate in urban indoor environments. The elements As, Cd, Cr, Cu, Hg, Ni and Pb and 12 selected polycyclic aromatic hydrocarbons (PAHs) were used to assess P. furfuracea as a biomonitoring tool for the indoor air quality of school environments. To achieve this purpose, lichen samples were exposed for 2 months in the outdoor and indoor environments of five school settings located in urban and rural areas. The results demonstrated that transplanted lichen P. furfuracea is a suitable biomonitoring tool for metals and PAHs in indoor settings and can discriminate between different levels of air pollution related to urbanisation and indoor conditions, such as those characterised by school environments. A transplanted lichen biomonitoring strategy is cost-effective, "green", educational for attending children and less "invasive" than traditional air sampling methods. The feasibility of indoor monitoring by P. furfuracea is a relevant finding and could be a key tool to improve air quality monitoring programmes in school scenarios and thus focus on health prevention interventions for children, who are one of the most susceptible groups in the population.

  4. Characterization of indoor bioaerosols from a hospital ward in a ...

    African Journals Online (AJOL)

    Characterization of indoor bioaerosols from a hospital ward in a tropical ... assessment of indoor air quality and determine pathogenic microorganisms due to particle fall-out. Key words: Indoor air, bioaerosols, hospital ward, tropical setting ...

  5. Assessment of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool environments (3–5 years old children)

    International Nuclear Information System (INIS)

    Oliveira, Marta; Slezakova, Klara; Delerue-Matos, Cristina; Pereira, Maria do Carmo; Morais, Simone

    2016-01-01

    This work characterizes levels of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air of preschool environments, and assesses the respective risks for 3–5-years old children. Eighteen gaseous and particulate (PM_1 and PM_2_._5) PAHs were collected indoors and outdoors during 63 days at preschools in Portugal. Gaseous PAHs accounted for 94–98% of total concentration (Σ_P_A_H_s). PAHs with 5–6 rings were predominantly found in PM_1 (54–74% particulate Σ_P_A_H_s). Lighter PAHs originated mainly from indoor sources whereas congeners with 4–6 rings resulted mostly from outdoor emissions penetration (motor vehicle, fuel burning). Total cancer risks of children were negligible according to USEPA, but exceeded (8–13 times) WHO health-based guideline. Carcinogenic risks due to indoor exposure were higher than for outdoors (4–18 times). - Highlights: • Lighter PAHs originate from indoor sources, 4–6 rings PAHs result from outdoors. • Gaseous PAHs account for the majority of PAH content in indoor air of preschools. • Lifetime lung cancer risk values exceed WHO health-based guideline level of 10"−"5. • Carcinogenic risks due to preschool indoor exposure are higher than for outdoors. - This work fills gap providing information on levels, phase distribution (gas, PM_1, PM_2_._5) and risks of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool settings.

  6. Assessment of radiological effect of the indoor radon and its progeny

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subbaramu, M.C.; Mishra, U.C.

    1988-01-01

    Of all the sources of environmental radiation, radon and its progeny are considered to be responsible for a significant dose to man, especially when they are in enclosed areas like underground mines, caves, cellars, poorly designed and badly ventilated houses. Linear extrapolation from the dose response value of the uranium miners exposed to higher levels of radon and its daughters also suggest that the majority of the lung cancer incidence could be due to radon. Higher indoor radon levels and shift in the disequilibrium of the progeny concentration in dwellings caused by the lower ventilation rate leads to severalfold increase of lung cancer incidence from radon. The large risk which is anticipated calls for further studies in this field and may also lead to the conclusion that the slight, but much feared, burden due to man-made radioactivity could be more than compensated by controlling critical segments of the environmental radioactivity. In this report the study of risk due to breathing of indoor radon is briefly reviewed. Dose equivalent to the exposed tissue of the respiratory tract of the people living in dwellings are evaluated. Like most of the risk assessment of low level radiation, the effort to quantify the effect of radon in terms of death rate dose due to lung cancer attributable to radon levels indoors, has to rely on the extrapolation from the effects of the higher exposure rate. In situations where soil or building materials contain elevated radium levels, living in energy efficient houses may be as dangerous as heavy smoking. (author). 8 tabs., 5 figs., 41 refs

  7. Indoor air pollution levels in public buildings in Thailand and exposure assessment.

    Science.gov (United States)

    Klinmalee, Aungsiri; Srimongkol, Kasama; Kim Oanh, Nguyen Thi

    2009-09-01

    Levels of pollutants including PM2.5 and PM2.5 composition (black carbon and water soluble ions), SO(2), NO(2), CO, CO(2), and BTEX (benzene, toluene, ethylbenzene, xylene) were monitored for indoor and outdoor air at a university campus and a shopping center, both located in the Northern suburb of Bangkok. Sampling was done during December 2005-February 2006 on both weekdays and weekends. At the university, indoor monitoring was done in two different air conditioned classrooms which shows the I/O ratios for all pollutants to be below 0.5-0.8 during the weekends. However, on weekdays the ratios for CO(2) and most detected BTEX were above 1.0. The concept of classroom occupancy was defined using a function of the student number in a lecture hour and the number of lecture hours per day. Classroom 2, which had a higher occupancy than classroom 1, was characterized by higher concentrations of most pollutants. PM2.5 was an exception and was higher in classroom 1 (37 microg/m(3), weekdays) as compared to classroom 2 (26 microg/m(3), weekdays) which was likely linked to the dust resuspension from the carpeted floor in the former. Monitoring was also done in the shopping mall at three different sites. Indoor pollutants levels and the I/O ratios at the shopping mall were higher than at the university. Levels of all pollutants measured at the car park, except for toluene and CO(2), were the highest. I/O ratios of the pollutants at the mall were above 1.0, which indicates the relatively higher influence of the indoor sources. However, the black carbon content in PM2.5 outdoor is higher than indoor, which suggest the important contribution from outdoor combustion sources such as the traffic. Major sources of outdoor air pollution in the areas were briefly discussed. Exposure modeling was applied using the time activity and measured pollutant concentrations to assess the exposure of different groups of people in the study areas. High exposure to PM2.5, especially for the people

  8. Assessment of indoor air quality at an electronic cigarette (Vaping) convention.

    Science.gov (United States)

    Chen, Rui; Aherrera, Angela; Isichei, Chineye; Olmedo, Pablo; Jarmul, Stephanie; Cohen, Joanna E; Navas-Acien, Ana; Rule, Ana M

    2017-12-29

    E-cigarette (vaping) conventions are public events promoting electronic cigarettes, in which indoor use of e-cigarettes is allowed. The large concentration of people using e-cigarettes and poor air ventilation can result in indoor air pollution. In order to estimate this worst-case exposure to e-cigarettes, we evaluated indoor air quality in a vaping convention in Maryland (MD), USA. Real-time concentrations of particulate matter (PM 10 ) and real-time total volatile organic compounds (TVOCs), CO 2 and NO 2 concentrations were measured. Integrated samples of air nicotine and PM 10 concentrations were also collected. The number of attendees was estimated to range from 75 to 600 at any single observation time. The estimated 24-h time-weighted average (TWA) PM 10 was 1800 μg/m 3 , 12-fold higher than the EPA 24-h regulation (150 μg/m 3 ). Median (range) indoor TVOCs concentration was 0.13 (0.04-0.3) ppm. PM 10 and TVOC concentrations were highly correlated with CO 2 concentrations, indicating the high number of people using e-cigarettes and poor indoor air quality. Air nicotine concentration was 125 μg/m 3 , equivalent to concentrations measured in bars and nightclubs. E-cigarette aerosol in a vaping convention that congregates many e-cigarette users is a major source of PM 10 , air nicotine and VOCs, impairing indoor air quality. These findings also raise occupational concerns for e-cigarette vendors and other venue staff workers.

  9. INDOOR SUBSPACING TO IMPLEMENT INDOORGML FOR INDOOR NAVIGATION

    Directory of Open Access Journals (Sweden)

    H. Jung

    2015-10-01

    Full Text Available According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  10. Indoor Subspacing to Implement Indoorgml for Indoor Navigation

    Science.gov (United States)

    Jung, H.; Lee, J.

    2015-10-01

    According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  11. Children's exposure to indoor air in urban nurseries-part I: CO{sub 2} and comfort assessment

    Energy Technology Data Exchange (ETDEWEB)

    Branco, P.T.B.S.; Alvim-Ferraz, M.C.M.; Martins, F.G.; Sousa, S.I.V., E-mail: sofia.sousa@fe.up.pt

    2015-07-15

    Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study “Children's exposure to indoor air in urban nurseries”, aimed to: i) evaluate nurseries’ indoor concentrations of carbon dioxide (CO{sub 2}), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters–temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO{sub 2} concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. - Highlights: • High occupation and poor ventilation were main determinants of IAQ in nurseries. • T and RH indoor values found in nurseries are likely to cause thermal discomfort. • Building characteristics and an inadequate ventilation determined T and RH values. • High CO{sub 2} concentrations found could indicate accumulation of other air pollutants.

  12. Indoor Air Nuclear, Biological, and Chemical Health Modeling and Assessment System

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, Robert D.; Hadley, Donald L.; Armstrong, Peter R.; Buck, John W.; Hoopes, Bonnie L.; Janus, Michael C.

    2001-03-01

    Indoor air quality effects on human health are of increasing concern to public health agencies and building owners. The prevention and treatment of 'sick building' syndrome and the spread of air-borne diseases in hospitals, for example, are well known priorities. However, increasing attention is being directed to the vulnerability of our public buildings/places, public security and national defense facilities to terrorist attack or the accidental release of air-borne biological pathogens, harmful chemicals, or radioactive contaminants. The Indoor Air Nuclear, Biological, and Chemical Health Modeling and Assessment System (IA-NBC-HMAS) was developed to serve as a health impact analysis tool for use in addressing these concerns. The overall goal was to develop a user-friendly fully functional prototype Health Modeling and Assessment system, which will operate under the PNNL FRAMES system for ease of use and to maximize its integration with other modeling and assessment capabilities accessible within the FRAMES system (e.g., ambient air fate and transport models, water borne fate and transport models, Physiologically Based Pharmacokinetic models, etc.). The prototype IA-NBC-HMAS is designed to serve as a functional Health Modeling and Assessment system that can be easily tailored to meet specific building analysis needs of a customer. The prototype system was developed and tested using an actual building (i.e., the Churchville Building located at the Aberdeen Proving Ground) and release scenario (i.e., the release and measurement of tracer materials within the building) to ensure realism and practicality in the design and development of the prototype system. A user-friendly "demo" accompanies this report to allow the reader the opportunity for a "hands on" review of the prototype system's capability.

  13. A systematic approach to assessing indoor air quality of long term care facilities

    NARCIS (Netherlands)

    te Kulve, M.; Loomans, M.G.L.C.; Huisman, E.R.C.M.; Kort, H.S.M.

    2018-01-01

    Not much is known about the favourable indoor air quality in long term care facilities (LTCFs), where older adults suffering from dementia live. Older adults, especially those who suffer from dementia, are more sensible to the indoor environment. However, no special requirements for the indoor air

  14. Assessment of indoor levels of volatile organic compounds and carbon dioxide in schools in Kuwait.

    Science.gov (United States)

    Al-Awadi, Layla

    2018-01-01

    Indoor air quality (IAQ) in schools is a matter of concern because children are most vulnerable and sensitive to pollutant exposure. Conservation of energy at the expense of ventilation in heating, ventilation, and air conditioning (HVAC) systems adversely affects IAQ. Extensive use of new materials in building, fitting, and refurbishing emit various pollutants such that the indoor environment creates its own discomfort and health risks. Various schools in Kuwait were selected to assess their IAQ. Comprehensive measurements of volatile organic compounds (VOCs) consisting of 72 organic compounds consisting of aliphatic (C 3 -C 6 ), aromatic (C 6 -C 9 ), halogenated (C 1 -C 7 ), and oxygenated (C 2 -C 9 ) functional groups in indoor air were made for the first time in schools in Kuwait. The concentrations of indoor air pollutants revealed hot spots (science preparation rooms, science laboratories, arts and crafts classes/paint rooms, and woodworking shops/decoration rooms where local sources contributed to the buildup of pollutants in each school. The most abundant VOC pollutant was chlorodifluoromethane (R22; ClF 2 CH), which leaked from air conditioning (AC) systems due to improper operation and maintenance. The other copious VOCs were alcohols and acetone at different locations due to improper handling of the chemicals and their excessive uses as solvents. Indoor carbon dioxide (CO 2 ) levels were measured, and these levels reflected the performance of HVAC systems; a specific rate or lack of ventilation affected the IAQ. Recommendations are proposed to mitigate the buildup of indoor air pollutants at school sites. Indoor air quality in elementary schools has been a subject of extreme importance due to susceptibility and sensibility of children to air pollutants. The schools were selected based on their surrounding environment especially downwind direction from the highly industrialized zone in Kuwait. Extensive sampling from different sites in four schools for

  15. Indoor Tanning Dependence in Young Adult Women.

    Science.gov (United States)

    Mays, Darren; Atkins, Michael B; Ahn, Jaeil; Tercyak, Kenneth P

    2017-11-01

    Background: There is mounting evidence that young people can develop a dependence on indoor tanning, but research on factors associated with indoor tanning dependence remains limited. Methods: This cross-sectional study investigated factors associated with indoor tanning dependence in a community sample of 389 non-Hispanic white young adult women ages 18 to 30 who had indoor tanned ≥1 time in the past year. Participants completed measures of indoor tanning dependence, including the modified CAGE and modified Diagnostic and Statistical Manual for Mental Disorders-IV psychiatric screening assessments, indoor tanning behavior and beliefs, and behavioral and psychiatric comorbidity. Results: Overall, 22.6% of the sample screened positive for indoor tanning dependence. In multivariable analyses, indoor tanning dependence was associated with younger age of indoor tanning initiation [adjusted odds ratio (aOR) = 0.79; P = 0.017], indoor tanning ≥20 times in the past year (aOR = 3.03; P = 0.015), stronger beliefs about the benefits of tanning (aOR = 2.15; P = 0.004), greater perceived susceptibility to indoor tanning risks (aOR = 2.72; P tanning dependence among young, non-Hispanic white women is associated with behaviors that increase the risk of skin cancer, beliefs favoring the perceived benefits of tanning, and comorbid risks such as stronger beliefs about physical appearance and depressed mood. Impact: Comprehensive skin cancer prevention efforts should address indoor tanning dependence among young women and its leading risk factors. Cancer Epidemiol Biomarkers Prev; 26(11); 1636-43. ©2017 AACR . ©2017 American Association for Cancer Research.

  16. Particle size: a missing factor in risk assessment of human exposure to toxic chemicals in settled indoor dust.

    Science.gov (United States)

    Cao, Zhi-Guo; Yu, Gang; Chen, Yong-Shan; Cao, Qi-Ming; Fiedler, Heidelore; Deng, Shu-Bo; Huang, Jun; Wang, Bin

    2012-11-15

    For researches on toxic chemicals in settled indoor dust, selection of dust fraction is a critical influencing factor to the accuracy of human exposure risk assessment results. However, analysis of the selection of dust fraction in recent studies revealed that there is no consensus. This study classified and presented researches on distribution of toxic chemicals according to dust particle size and on relationship between dust particle size and human exposure possibility. According to the literature, beyond the fact that there were no consistent conclusions on particle size distribution of adherent fraction, dust with particle size less than 100 μm should be paid more attention and that larger than 250 μm is neither adherent nor proper for human exposure risk assessment. Calculation results based on literature data show that with different selections of dust fractions, analytical results of toxic chemicals would vary up to 10-fold, which means that selecting dust fractions arbitrarily will lead to large errors in risk assessment of human exposure to toxic chemicals in settled dust. Taking into account the influence of dust particle size on risk assessment of human exposure to toxic chemicals, a new methodology for risk assessment of human exposure to toxic chemicals in settled indoor dust is proposed and human exposure parameter systems to settled indoor dust are advised to be established at national and regional scales all over the world. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Indoor air pollution: a public health perspective

    International Nuclear Information System (INIS)

    Spengler, J.D.; Sexton, K.

    1983-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms, and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  18. Indoor air-assessment: Indoor concentrations of environmental carcinogens

    International Nuclear Information System (INIS)

    Gold, K.W.; Naugle, D.F.; Berry, M.A.

    1991-01-01

    In the report, indoor concentration data are presented for the following general categories of air pollutants: radon-222, environmental tobacco smoke (ETS), asbestos, gas phase organic compounds, formaldehyde, polycyclic aromatic hydrocarbons (PAH), pesticides, and inorganic compounds. These pollutants are either known or suspect carcinogens (i.e., radon-222, asbestos) or more complex mixtures or classes of compounds which contain known or suspect carcinogens. Concentration data for individual carcinogenic compounds in complex mixtures are usually far from complete. The data presented for complex mixtures often include compounds which are not carcinogenic or for which data are insufficient to evaluate carcinogenicity. Their inclusion is justified, however, by the possibility that further work may show them to be carcinogens, cocarcinogens, initiators or promotors, or that they may be employed as markers (e.g., nicotine, acrolein) for the estimation of exposure to complex mixtures

  19. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  20. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  1. Indoor environmental quality in Hellenic hospital operating rooms

    Energy Technology Data Exchange (ETDEWEB)

    Dascalaki, Elena G.; Gaglia, Athina G.; Balaras, Constantinos A. [Group Energy Conservation, Institute for Environmental Research and Sustainable Development, National Observatory of Athens, I. Metaxa and Vas. Pavlou, GR 152 36 P. Penteli (Greece); Lagoudi, Argyro [Terra Nova Ltd., Environmental Engineering Consultancy, Athens, Kaisareias 39, GR 115 27 Athens (Greece)

    2009-05-15

    Indoor environmental quality (IEQ) in hospital operating rooms (ORs) constitutes a major challenge for the proper design and operation of an energy efficient hospital. A subjective assessment of the indoor environment along with a short monitoring campaign was performed during the audits of 18 ORs at nine major Hellenic hospitals. A total of 557 medical personnel participated in an occupational survey, providing data for a subjective assessment of IEQ in the audited ORs. The OR personnel reported work related health symptoms and an assessment of indoor conditions (thermal, visual and acoustical comfort, and air quality). Overall, personnel reported an average of 2.24 work-related symptoms each, and 67.2% of respondents reported at least one. Women suffer more health symptoms than men. Special dispositions, such as smoking and allergies, increase the number of reported symptoms for male and female personnel. Personnel that perceive satisfactory indoor comfort conditions (temperature, humidity, ventilation, light, and noise) average 1.18 symptoms per person, while for satisfactory indoor air quality the average complaints are 0.99. The perception of satisfactory IEQ (satisfactory comfort conditions and air quality) reduces the average number of health complaints to 0.64 symptoms per person and improves working conditions, even in a demanding OR environment. (author)

  2. Indoor environment and pupils' health in primary schools

    DEFF Research Database (Denmark)

    van Dijken, F.; van Bronswijk, J.E.M.H.; Sundell, Jan

    2006-01-01

    the associations between indoor environmental quality in Dutch schools and pupils' health, also taking into account the children's home environment and personal factors. A cross-sectional study was performed in 11 classrooms in 11 different schools in the Netherlands. The study included exposure measurements......Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess......, building inspections, and a questionnaire survey on pupils' health and domestic exposure. Principal Component Analysis (PCA) and non-parametric tests were performed to assess relationships. None of the schools complied with all indoor environmental quality standards. The importance of both the school...

  3. Office of radiation and indoor air: Program description

    International Nuclear Information System (INIS)

    1993-06-01

    The goal of the Environmental Protection Agency's (EPA) Office of Radiation and Indoor Air is to protect the public and the environment from exposures to radiation and indoor air pollutants. The Office develops protection criteria, standards, and policies and works with other programs within EPA and other agencies to control radiation and indoor air pollution exposures; provides technical assistance to states through EPA's regional offices and other agencies having radiation and indoor air protection programs; directs an environmental radiation monitoring program; responds to radiological emergencies; and evaluates and assesses the overall risk and impact of radiation and indoor air pollution. The Office is EPA's lead office for intra- and interagency activities coordinated through the Committee for Indoor Air Quality. It coordinates with and assists the Office of Enforcement in enforcement activities where EPA has jurisdiction. The Office disseminates information and works with state and local governments, industry and professional groups, and citizens to promote actions to reduce exposures to harmful levels of radiation and indoor air pollutants

  4. Lifetime history of indoor tanning in young people: a retrospective assessment of initiation, persistence, and correlates

    Directory of Open Access Journals (Sweden)

    Lostritto Karen

    2012-02-01

    Full Text Available Abstract Background Despite educational and public health campaigns to convey the risks of indoor tanning, many individuals around the world continue to engage in this behavior. Few descriptive studies of indoor tanning have collected information pertaining to the lifetime history of indoor tanning, thereby limiting our ability to understand indoor tanning patterns and potentially target interventions for individuals who not only initiate, but continue to persistently engage in indoor tanning. Methods In-person interviews elicited detailed retrospective information on lifetime history of indoor tanning among white individuals (n = 401 under age 40 seen by a dermatologist for a minor benign skin condition. These individuals were controls in a case-control study of early-onset basal cell carcinoma. Outcomes of interest included ever indoor tanning in both males and females, as well as persistent indoor tanning in females - defined as females over age 31 who tanned indoors at least once in the last three or all four of four specified age periods (ages 11-15, 16-20, 21-30 and 31 or older. Multivariate logistic regression was used to identify sociodemographic and lifestyle correlates of ever and persistent indoor tanning in females. Results Approximately three-quarters (73.3% of females and 38.3% of males ever tanned indoors, with a median age of initiation of 17.0 and 21.5, respectively. Among indoor tanners, 39.3% of females and 21.7% of males reported being burned while indoor tanning. Female ever indoor tanners were younger, had darker color eyes, and sunbathed more frequently than females who never tanned indoors. Using unique lifetime exposure data, 24.7% of female indoor tanners 31 and older persistently tanned indoors starting as teenagers. Female persistent indoor tanners drank significantly more alcohol, were less educated, had skin that tanned with prolonged sun exposure, and sunbathed outdoors more frequently than non-persistent tanners

  5. Indoor Air Quality Assessment and Study of Different VOC Contributions within a School in Taranto City, South of Italy

    Directory of Open Access Journals (Sweden)

    Annalisa Marzocca

    2017-03-01

    Full Text Available Children spend a large amount of time in school environments and when Indoor Air Quality (IAQ is poor, comfort, productivity and learning performances may be affected. The aim of the present study is to characterize IAQ in a primary school located in Taranto city (south of Italy. Because of the proximity of a large industrial complex to the urban settlement, this district is one of the areas identified as being at high environmental risk in Italy. The study carried out simultaneous monitoring of indoor and outdoor Volatile Organic Compounds (VOC concentrations and assessed different pollutants’ contributions on the IAQ of the investigated site. A screening study of VOC and determination of Benzene, Toluene, Ethylbenzene, Xylenes (BTEX, sampled with Radiello® diffusive samplers suitable for thermal desorption, were carried out in three classrooms, in the corridor and in the yard of the school building. Simultaneously, Total VOC (TVOC concentration was measured by means of real-time monitoring, in order to study the activation of sources during the monitored days. The analysis results showed a prevalent indoor contribution for all VOC except for BTEX which presented similar concentrations in indoor and outdoor air. Among the determined VOC, Terpenes and 2-butohxyethanol were shown to be an indoor source, the latter being the indoor pollutant with the highest concentration.

  6. An assessment of ecological and case-control methods for estimating lung cancer risk due to indoor radon

    International Nuclear Information System (INIS)

    Stidley, C.A.; Samet, J.M.

    1992-01-01

    Studies of underground miners indicate that indoor radon is an important cause of lung cancer. This finding has raised concern that exposure to radon also causes lung cancer in the general population. Epidemiological studies, including both case-control and ecological approaches, have directly addressed the risks of indoor residential radon; many more case-control studies are in progress. Ecological studies that associate lung-cancer rates with typical indoor radon levels in various geographic areas have not consistently shown positive associations. The results of purportedly negative ecological studies have been used as a basis for questioning the hazards of indoor radon exposure. Because of potentially serious methodologic flaws for testing hypotheses, we examined the ecological method as a tool for assessing lung-cancer risk from indoor radon exposure. We developed a simulation approach that utilizes the Environmental Protection Agency (EPA) radon survey data to assign exposures to individuals within counties. Using the computer-generated data, we compared risk estimates obtained by ecological regression methods with those obtained from other regression methods and with the open-quotes trueclose quotes risks used to generate the data. For many of these simulations, the ecological models, while fitting the summary data well, gave risk estimates that differed considerably from the true risks. For some models, the risk estimates were negatively correlated with exposure, although the assumed relationship was positive. Attempts to improve the ecological models by adding smoking variables, including interaction terms, did not always improve the estimates of risk, which are easily affected by model misspecification. Because exposure situations used in the simulations are realistic, our results show that ecological methods may not accurately estimate the lung-cancer risk associated with indoor radon exposure

  7. Indoor air-quality measurements in energy-efficient residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Berk, J.V.; Hollowell, C.D.; Pepper, J.H.; Young, R.

    1980-05-01

    The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

  8. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  9. Indoor environment and pupils' health in primary schools

    NARCIS (Netherlands)

    van Dijken, F; Bronswijk, van J.E.M.H.; Sundell, J.

    2006-01-01

    Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess the

  10. Core public health functions for BC : evidence review : air quality-indoor

    Energy Technology Data Exchange (ETDEWEB)

    Copes, R.; Ouellette, V.; Lee, K.S.; Brauer, M. [British Columbia Ministry of Health, Victoria, BC (Canada)

    2006-04-15

    Indoor sources of pollutants can have a major impact on the health of Canadians, as pollutant concentrations are often higher indoors than outdoors. This paper assessed data compiled by public health indoor air interventions. The aim of the study was to identify the current state of evidence on the impacts of indoor pollution in order to develop performance improvement plans for public health programs in British Columbia (BC). The literature review used several databases to review interventions involving humidity control; ventilation; particulate matter; indoor allergens; and environmental tobacco smoke. Results of the review showed that improving inadequate ventilation can significantly decrease the prevalence of sick building syndrome as well as other self-reported symptoms attributed to indoor air pollution. A review of the literature also demonstrated that many building ventilation systems are not functioning to design specifications. The poor quality of studies on the health impacts of particulate matter or dust made it difficult to fully assess the benefits of particle filtration on human health. Studies investigating the impacts of controlling indoor allergens suggested that the avoidance of dust mites may benefit people with allergies. Evidence gained from studies on environmental tobacco smoke showed that banning or restricting smoking will reduce the burden of illness from pollutants in indoor air. 20 refs., 3 tabs.

  11. Core public health functions for BC : evidence review : air quality-indoor

    International Nuclear Information System (INIS)

    Copes, R.; Ouellette, V.; Lee, K.S.; Brauer, M.

    2006-04-01

    Indoor sources of pollutants can have a major impact on the health of Canadians, as pollutant concentrations are often higher indoors than outdoors. This paper assessed data compiled by public health indoor air interventions. The aim of the study was to identify the current state of evidence on the impacts of indoor pollution in order to develop performance improvement plans for public health programs in British Columbia (BC). The literature review used several databases to review interventions involving humidity control; ventilation; particulate matter; indoor allergens; and environmental tobacco smoke. Results of the review showed that improving inadequate ventilation can significantly decrease the prevalence of sick building syndrome as well as other self-reported symptoms attributed to indoor air pollution. A review of the literature also demonstrated that many building ventilation systems are not functioning to design specifications. The poor quality of studies on the health impacts of particulate matter or dust made it difficult to fully assess the benefits of particle filtration on human health. Studies investigating the impacts of controlling indoor allergens suggested that the avoidance of dust mites may benefit people with allergies. Evidence gained from studies on environmental tobacco smoke showed that banning or restricting smoking will reduce the burden of illness from pollutants in indoor air. 20 refs., 3 tabs

  12. Analysis of indoor air pollutants checklist using environmetric technique for health risk assessment of sick building complaint in nonindustrial workplace

    Directory of Open Access Journals (Sweden)

    Syazwan AI

    2012-09-01

    Full Text Available AI Syazwan,1 B Mohd Rafee,1 Hafizan Juahir,2 AZF Azman,1 AM Nizar,3 Z Izwyn,4 K Syahidatussyakirah,1 AA Muhaimin,5 MA Syafiq Yunos,6 AR Anita,1 J Muhamad Hanafiah,1 MS Shaharuddin,7 A Mohd Ibthisham,8 I Mohd Hasmadi,9 MN Mohamad Azhar,1 HS Azizan,1 I Zulfadhli,10 J Othman,11 M Rozalini,12 FT Kamarul131Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, 2Department of Environmental Science/ Environmental Forensics Research Center (ENFORCE, Universiti Putra Malaysia, Selangor, 3Pharmacology Unit, Department of Human Anatomy, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, 43400 Serdang, Selangor, 4Department of Therapy and Rehabilitation, Faculty of Health Science and Biomedical Engineering, Universiti Teknologi Malaysia, Johor, 5Department of Environmental Management, Faculty of Environmental Studies, Universiti Putra Malaysia, Selangor, 6Plant Assessment Technology (PAT, Industrial Technology Division, Malaysian Nuclear Agency, Bangi, 7Department of Environmental and Occupational Health Science, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, 8Department of Mechanical Engineering, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Johor, 9Department of Forest Production, Faculty of Forestry, Universiti Putra Malaysia, Selangor, 10Faculty of Built Environment and Architect, Universiti Teknologi Malaysia, Johor, 11Department of Counselor Education and Psychology Counseling, Faculty of Educational Studies, Universiti Putra Malaysia, Selangor, 12Occupational Safety, Health and Environment Unit, Multimedia University, Jalan Multimedia 63100 Cyberjaya, Selangor, 13ERALAB SDN. BHD. (Environmental Research and Analytical Laboratory Sdn. Bhd., Selangor, MALAYSIAPurpose: To analyze and characterize a multidisciplinary, integrated indoor air quality checklist for evaluating the health risk of building occupants in a nonindustrial

  13. Indoor Chemistry

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Carslaw, Nicola

    2018-01-01

    This review aims to encapsulate the importance, ubiquity, and complexity of indoor chemistry. We discuss the many sources of indoor air pollutants and summarize their chemical reactions in the air and on surfaces. We also summarize some of the known impacts of human occupants, who act as sources...... and sinks of indoor chemicals, and whose activities (e.g., cooking, cleaning, smoking) can lead to extremely high pollutant concentrations. As we begin to use increasingly sensitive and selective instrumentation indoors, we are learning more about chemistry in this relatively understudied environment....

  14. Environmental assessment of three egg production systems--Part I: Monitoring system and indoor air quality.

    Science.gov (United States)

    Zhao, Y; Shepherd, T A; Li, H; Xin, H

    2015-03-01

    To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens' activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall

  15. Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality

    Science.gov (United States)

    Zhao, Y.; Shepherd, T. A.; Li, H.; Xin, H.

    2015-01-01

    To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens’ activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall

  16. Indoor Environment Program

    International Nuclear Information System (INIS)

    Daisey, J.M.

    1993-06-01

    This paper reports progress during the year 1992 in the Indoor Environment Program in the Energy and Environment Division of Lawrence Berkeley Laboratory. Studies in the following areas are reported: energy performance and ventilation in buildings; physical and chemical characterization of indoor air pollutants; indoor radon; indoor air quality; exposure to indoor air pollutants and risk analysis. Pollutants of particular interest include: radon; volatile, semi-volatile and particulate organic compounds; and combustion emissions including environmental tobacco smoke, carbon monoxide, and nitrogen oxides

  17. Evaluation on potential for assessing indoor formaldehyde using biosensor system based on swimming behavior of Japanese medaka (oryzias latipes)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jonghun [Department of Architecture, The University of Tokyo, 4-6-1 Komaba, Meguro-Ku, Tokyo, 153-8505 (Japan); Kato, Shinsuke; Tatsuma, Tetsu [Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-Ku, Tokyo, 153-8505 (Japan); Takeuchi, Kenichiro [Sumitomo Forestry Co., Ltd. (Japan); Kang, Ik Joon [Aquatic Biomonitoring and Environmental Laboratory, Department of Bioscience and Biotechnology, Faculty of Agriculture, Kyushu University, Fukuoka, 812-8581 (Japan)

    2011-04-15

    In order to develop an early-warning biosensor system for predicting the impact on health of long-term and low-level exposure to indoor chemical compounds, e.g. volatile organic compounds (VOCs), we evaluated the potential for assessing indoor air quality using the biosensor system based on the swimming behavior of Japanese medaka (oryzias latipes) as an indicator of indoor air quality in the beginning. As a technology to dissolve chemical compounds into water efficiently, a micro bubble generator was introduced. The test chemical was formaldehyde which is a representative of chemical compounds existing indoors. The result of the measuring solubility of formaldehyde was that formaldehyde concentration in water was raised to 0.12 mg/L when 1.0 mg/m{sup 3} of formaldehyde in air was bubbled for approximately 44 h. The correlation between the 0.1 mg/L of formaldehyde in water, which is roughly equivalent to 0.83 mg/m{sup 3} of formaldehyde in air, and the swimming activities of medaka was investigated. The fish showed abnormal behavior compared to one under a control treatment, e.g. the body movement distance decreased and the duration time near the upper water column increased significantly. It was verified that it is possible to detect concentrations of formaldehyde of 0.83 mg/m{sup 3} in indoor air using this proposed biosensor system. (author)

  18. Indoor air. Seminar of Zentrale Informationsstelle, Umweltberatung Bayern. Vol. 2

    International Nuclear Information System (INIS)

    Koller, U.; Haury, H.J.

    1994-02-01

    This seminar dealt with the subject of indoor air pollution and welcomed participants from environmental consultancy agencies and authorities and institutions related with environmental protection. Leading scientists from research and authorities presented the current state of knowledge abut the risks of indoorair pollution. The papers contained in these proceedings addressed: room climate and sick-building syndrome; allergens in indoor spaces; pollutants emitted by exemplary building materials; pollutant levels of organic compounds in indoor spaces; air quality in motor vehicle interiors; indoor air pollution - risk assessment and need for actions. (Uhe) [de

  19. Health effects and sources of indoor air pollution. Part I

    International Nuclear Information System (INIS)

    Samet, J.M.; Marbury, M.C.; Spengler, J.D.

    1987-01-01

    Since the early 1970s, the health effects of indoor air pollution have been investigated with increasing intensity. Consequently, a large body of literature is now available on diverse aspects of indoor air pollution: sources, concentrations, health effects, engineering, and policy. This review begins with a review of the principal pollutants found in indoor environments and their sources. Subsequently, exposure to indoor air pollutants and health effects are considered, with an emphasis on those indoor air quality problems of greatest concern at present: passive exposure to tobacco smoke, nitrogen dioxide from gas-fueled cooking stoves, formaldehyde exposure, radon daughter exposure, and the diverse health problems encountered by workers in newer sealed office buildings. The review concludes by briefly addressing assessment of indoor air quality, control technology, research needs, and clinical implications. 243 references

  20. Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Logue, J.M.; Price, P.N.; Sherman, M.H.; Singer, B.C.

    2011-07-01

    Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

  1. Quantification of differences between occupancy and total monitoring periods for better assessment of exposure to particles in indoor environments

    Science.gov (United States)

    Wierzbicka, A.; Bohgard, M.; Pagels, J. H.; Dahl, A.; Löndahl, J.; Hussein, T.; Swietlicki, E.; Gudmundsson, A.

    2015-04-01

    For the assessment of personal exposure, information about the concentration of pollutants when people are in given indoor environments (occupancy time) are of prime importance. However this kind of data frequently is not reported. The aim of this study was to assess differences in particle characteristics between occupancy time and the total monitoring period, with the latter being the most frequently used averaging time in the published data. Seven indoor environments were selected in Sweden and Finland: an apartment, two houses, two schools, a supermarket, and a restaurant. They were assessed for particle number and mass concentrations and number size distributions. The measurements using a Scanning Mobility Particle Sizer and two photometers were conducted for seven consecutive days during winter in each location. Particle concentrations in residences and schools were, as expected, the highest during occupancy time. In the apartment average and median PM2.5 mass concentrations during the occupancy time were 29% and 17% higher, respectively compared to total monitoring period. In both schools, the average and medium values of the PM2.5 mass concentrations were on average higher during teaching hours compared to the total monitoring period by 16% and 32%, respectively. When it comes to particle number concentrations (PNC), in the apartment during occupancy, the average and median values were 33% and 58% higher, respectively than during the total monitoring period. In both houses and schools the average and median PNC were similar for the occupancy and total monitoring periods. General conclusions on the basis of measurements in the limited number of indoor environments cannot be drawn. However the results confirm a strong dependence on type and frequency of indoor activities that generate particles and site specificity. The results also indicate that the exclusion of data series during non-occupancy periods can improve the estimates of particle concentrations and

  2. Indoor air pollution and cognitive function among older Mexican adults.

    Science.gov (United States)

    Saenz, Joseph L; Wong, Rebeca; Ailshire, Jennifer A

    2018-01-01

    A growing body of research suggests exposure to high levels of outdoor air pollution may negatively affect cognitive functioning in older adults, but less is known about the link between indoor sources of air pollution and cognitive functioning. We examine the association between exposure to indoor air pollution and cognitive function among older adults in Mexico, a developing country where combustion of biomass for domestic energy remains common. Data come from the 2012 Wave of the Mexican Health and Aging Study. The analytic sample consists of 13 023 Mexican adults over age 50. Indoor air pollution is assessed by the reported use of wood or coal as the household's primary cooking fuel. Cognitive function is measured with assessments of verbal learning, verbal recall, attention, orientation and verbal fluency. Ordinary least squares regression is used to examine cross-sectional differences in cognitive function according to indoor air pollution exposure while accounting for demographic, household, health and economic characteristics. Approximately 16% of the sample reported using wood or coal as their primary cooking fuel, but this was far more common among those residing in the most rural areas (53%). Exposure to indoor air pollution was associated with poorer cognitive performance across all assessments, with the exception of verbal recall, even in fully adjusted models. Indoor air pollution may be an important factor for the cognitive health of older Mexican adults. Public health efforts should continue to develop interventions to reduce exposure to indoor air pollution in rural Mexico. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa.

    Science.gov (United States)

    Naicker, Nisha; Teare, June; Balakrishna, Yusentha; Wright, Caradee Yael; Mathee, Angela

    2017-11-18

    Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb) from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types ( p informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  4. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa

    Directory of Open Access Journals (Sweden)

    Nisha Naicker

    2017-11-01

    Full Text Available Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types (p < 0.0001. Low cost government-built houses and informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  5. Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality

    Directory of Open Access Journals (Sweden)

    Katja Tähtinen

    2018-04-01

    Full Text Available The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account.

  6. Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality.

    Science.gov (United States)

    Tähtinen, Katja; Lappalainen, Sanna; Karvala, Kirsi; Remes, Jouko; Salonen, Heidi

    2018-04-04

    The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ) measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA) questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account.

  7. Assessment of risk perception connected with exposure to indoor air pollution in the group of inhabitants of Silesian Voivodeship

    Directory of Open Access Journals (Sweden)

    Karolina Krupa

    2012-09-01

    Full Text Available Introduction. Population increasingly draws attention to the issues concerning the environment degraded by the progress of civilization and the impact of this process on health. However, public awareness of the risk exposure to indoor contaminants is lagging a long way behind knowledge regarding outdoor environmental hazards. The aim of the study was to assess the risk perception related to exposure to indoor environmental factors in the population of Silesia. Materials and methods. In this study the electronic version of a questionnaire survey – downloaded on the website www.moja-ankiety.pl. was used. During the 3-months duration of the project 552 subjects participated in the survey. In the study participated the Silesian Voivodeship inhabitants such as chat rooms users, newsgroups and online forum participants. Data analysis was performed by using statistical program – STATA Version 8 SE [9], where the Kruskall-Wallis test and χ2 test were applied. Statistical significance was assessed at p value *0.05. Results. Despite the low perception of environmental health hazards inside the dwellings, the majority of respondents were able to indentify health effects and ways to reduce exposure to indoor air pollution. Both gender, place of residence, education level and age significantly affected the level of perception of respondents on the risk connected with exposure to indoor air pollution. Conclusion. It is necessary to continuously work on raising public awareness of environmental health hazards in confined spaces, the causes of their occurrence, types, effects and above all the ways to counter these threats.

  8. Healthy indoors : achieving healthy indoor environments in Canada : Final report

    International Nuclear Information System (INIS)

    Anon

    2002-01-01

    A large proportion of the lives of Canadians is spent indoors, whether in vehicles, restaurants, shopping malls, offices or houses. The health of people working and living in those indoor settings might be damaged a a result, despite best efforts. Indoor pollution has been identified as one of the most serious risks to human health, according to numerous leading authorities, among them the American Lung Association, the United States Environmental Protection Agency, the Canada Mortgage and Housing Corporation (CMHC). A large number of cancer deaths are attributed to indoor pollution each year in the United States, as well as respiratory health problems. A causal link between certain indoor exposures and the development and provocation of asthma was established recently in a report on asthma and indoor air quality published by the National Academy of Sciences/Institute of Medicine. Exposure to indoor pollutants has also resulted in thousands of children experiencing elevated blood lead levels. Not enough attention is paid in Canada to pollution in buildings by government agencies, corporations and other non-governmental organizations and citizens. Not much seems to have changed in the past thirty years. An ambitious strategy by Pollution Probe was described in this document, listing the initial goals and measures required to achieve those goals. The creation of Healthy Indoors Partnership (HIP) was proposed to regroup all the stakeholders under the same umbrella. refs., tabs

  9. Assessment of indoor and outdoor PM species at schools and residences in a high-altitude Ecuadorian urban center.

    Science.gov (United States)

    Raysoni, Amit U; Armijos, Rodrigo X; Weigel, M Margaret; Montoya, Teresa; Eschanique, Patricia; Racines, Marcia; Li, Wen-Whai

    2016-07-01

    An air monitoring campaign to assess children's environmental exposures in schools and residences, both indoors and outdoors, was conducted in 2010 in three low-income neighborhoods in Z1 (north), Z2 (central), and Z3 (southeast) zones of Quito, Ecuador - a major urban center of 2.2 million inhabitants situated 2850 m above sea level in a narrow mountainous basin. Z1 zone, located in northern Quito, historically experienced emissions from quarries and moderate traffic. Z2 zone was influenced by heavy traffic in contrast to Z3 zone which experienced low traffic densities. Weekly averages of PM samples were collected at schools (one in each zone) and residences (Z1 = 47, Z2 = 45, and Z3 = 41) every month, over a twelve-month period at the three zones. Indoor PM2.5 concentrations ranged from 10.6 ± 4.9 μg/m(3) (Z1 school) to 29.0 ± 30.5 μg/m(3) (Z1 residences) and outdoor PM2.5 concentrations varied from 10.9 ± 3.2 μg/m(3) (Z1 school) to 14.3 ± 10.1 μg/m(3) (Z2 residences), across the three zones. The lowest values for PM10-2.5 for indoor and outdoor microenvironments were recorded at Z2 school, 5.7 ± 2.8 μg/m(3) and 7.9 ± 2.2 μg/m(3), respectively. Outdoor school PM concentrations exhibited stronger associations with corresponding indoor values making them robust proxies for indoor exposures in naturally ventilated Quito public schools. Correlation analysis between the school and residential PM size fractions and the various pollutant and meteorological parameters from central ambient monitoring (CAM) sites suggested varying degrees of temporal relationship. Strong positive correlation was observed for outdoor PM2.5 at Z2 school and its corresponding CAM site (r = 0.77) suggesting common traffic related emissions. Spatial heterogeneity in PM2.5 concentrations between CAM network and sampled sites was assessed using Coefficient of Divergence (COD) analysis. COD values were lower when CAM sites were paired with outdoor

  10. Sampling strategies for indoor radon investigations

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1983-01-01

    Recent investigations prompted by concern about the environmental effects of residential energy conservation have produced many accounts of indoor radon concentrations far above background levels. In many instances time-normalized annual exposures exceeded the 4 WLM per year standard currently used for uranium mining. Further investigations of indoor radon exposures are necessary to judge the extent of the problem and to estimate the practicality of health effects studies. A number of trends can be discerned as more indoor surveys are reported. It is becoming increasingly clear that local geological factors play a major, if not dominant role in determining the distribution of indoor radon concentrations in a given area. Within a giving locale, indoor radon concentrations tend to be log-normally distributed, and sample means differ markedly from one region to another. The appreciation of geological factors and the general log-normality of radon distributions will improve the accuracy of population dose estimates and facilitate the design of preliminary health effects studies. The relative merits of grab samples, short and long term integrated samples, and more complicated dose assessment strategies are discussed in the context of several types of epidemiological investigations. A new passive radon sampler with a 24 hour integration time is described and evaluated as a tool for pilot investigations

  11. Analysis of indoor air pollutants checklist using environmetric technique for health risk assessment of sick building complaint in nonindustrial workplace.

    Science.gov (United States)

    Syazwan, Ai; Rafee, B Mohd; Juahir, Hafizan; Azman, Azf; Nizar, Am; Izwyn, Z; Syahidatussyakirah, K; Muhaimin, Aa; Yunos, Ma Syafiq; Anita, Ar; Hanafiah, J Muhamad; Shaharuddin, Ms; Ibthisham, A Mohd; Hasmadi, I Mohd; Azhar, Mn Mohamad; Azizan, Hs; Zulfadhli, I; Othman, J; Rozalini, M; Kamarul, Ft

    2012-01-01

    To analyze and characterize a multidisciplinary, integrated indoor air quality checklist for evaluating the health risk of building occupants in a nonindustrial workplace setting. A cross-sectional study based on a participatory occupational health program conducted by the National Institute of Occupational Safety and Health (Malaysia) and Universiti Putra Malaysia. A modified version of the indoor environmental checklist published by the Department of Occupational Health and Safety, based on the literature and discussion with occupational health and safety professionals, was used in the evaluation process. Summated scores were given according to the cluster analysis and principal component analysis in the characterization of risk. Environmetric techniques was used to classify the risk of variables in the checklist. Identification of the possible source of item pollutants was also evaluated from a semiquantitative approach. Hierarchical agglomerative cluster analysis resulted in the grouping of factorial components into three clusters (high complaint, moderate-high complaint, moderate complaint), which were further analyzed by discriminant analysis. From this, 15 major variables that influence indoor air quality were determined. Principal component analysis of each cluster revealed that the main factors influencing the high complaint group were fungal-related problems, chemical indoor dispersion, detergent, renovation, thermal comfort, and location of fresh air intake. The moderate-high complaint group showed significant high loading on ventilation, air filters, and smoking-related activities. The moderate complaint group showed high loading on dampness, odor, and thermal comfort. This semiquantitative assessment, which graded risk from low to high based on the intensity of the problem, shows promising and reliable results. It should be used as an important tool in the preliminary assessment of indoor air quality and as a categorizing method for further IAQ

  12. Model for screening-level assessment of near-field human exposure to neutral organic chemicals released indoors.

    Science.gov (United States)

    Zhang, Xianming; Arnot, Jon A; Wania, Frank

    2014-10-21

    Screening organic chemicals for hazard and risk to human health requires near-field human exposure models that can be readily parametrized with available data. The integration of a model of human exposure, uptake, and bioaccumulation into an indoor mass balance model provides a quantitative framework linking emissions in indoor environments with human intake rates (iRs), intake fractions (iFs) and steady-state concentrations in humans (C) through consideration of dermal permeation, inhalation, and nondietary ingestion exposure pathways. Parameterized based on representative indoor and adult human characteristics, the model is applied here to 40 chemicals of relevance in the context of human exposure assessment. Intake fractions and human concentrations (C(U)) calculated with the model based on a unit emission rate to air for these 40 chemicals span 2 and 5 orders of magnitude, respectively. Differences in priority ranking based on either iF or C(U) can be attributed to the absorption, biotransformation and elimination processes within the human body. The model is further applied to a large data set of hypothetical chemicals representative of many in-use chemicals to show how the dominant exposure pathways, iF and C(U) change as a function of chemical properties and to illustrate the capacity of the model for high-throughput screening. These simulations provide hypotheses for the combination of chemical properties that may result in high exposure and internal dose. The model is further exploited to highlight the role human contaminant uptake plays in the overall fate of certain chemicals indoors and consequently human exposure.

  13. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  14. Climate change and health: Indoor heat exposure in vulnerable populations

    International Nuclear Information System (INIS)

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Timothy Dvonch, J.; O'Neill, Marie S.

    2012-01-01

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.

  15. Indoor and Outdoor Surface-Growing Fungi Contamination at Higher Institutional Buildings in a Malaysian University

    Science.gov (United States)

    Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.

    2018-04-01

    Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (pair quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.

  16. Indoor multipath mitigation

    DEFF Research Database (Denmark)

    Dragünas, Kostas; Borre, Kai

    2010-01-01

    There are many applications that require continuous positioning in combined outdoor urban and indoor environments. GNSS has been used for a long time in outdoor environments, while indoor positioning is still a challenging task. One of the major degradations that GNSS receivers experience indoors...

  17. Health effects of indoor odorants.

    Science.gov (United States)

    Cone, J E; Shusterman, D

    1991-11-01

    People assess the quality of the air indoors primarily on the basis of its odors and on their perception of associated health risk. The major current contributors to indoor odorants are human occupant odors (body odor), environmental tobacco smoke, volatile building materials, bio-odorants (particularly mold and animal-derived materials), air fresheners, deodorants, and perfumes. These are most often present as complex mixtures, making measurement of the total odorant problem difficult. There is no current method of measuring human body odor, other than by human panel studies of expert judges of air quality. Human body odors have been quantitated in terms of the "olf" which is the amount of air pollution produced by the average person. Another quantitative unit of odorants is the "decipol," which is the perceived level of pollution produced by the average human ventilated by 10 L/sec of unpolluted air or its equivalent level of dissatisfaction from nonhuman air pollutants. The standard regulatory approach, focusing on individual constituents or chemicals, is not likely to be successful in adequately controlling odorants in indoor air. Besides the current approach of setting minimum ventilation standards to prevent health effects due to indoor air pollution, a standard based on the olf or decipol unit might be more efficacious as well as simpler to measure.

  18. Immediate impact of smoke-free laws on indoor air quality.

    Science.gov (United States)

    Lee, Kiyoung; Hahn, Ellen J; Riker, Carol; Head, Sara; Seithers, Peggy

    2007-09-01

    Smoke-free laws significantly impact indoor air quality. However, the temporal effects of these laws on indoor air pollution have not been determined. This paper assesses the temporal impact of one smoke-free law on indoor air quality. This quasi-experimental study compared the indoor air quality of nine hospitality venues and one bingo hall in Georgetown, Kentucky, before and after implementation of a 100% smoke-free workplace law. We made real-time measurements of particulate matter with 2.5 microm aerodynamic diameter or smaller (PM2.5). Among the nine Georgetown hospitality venues, the average indoor PM2.5 concentration was 84 microg/m3 before the law took effect. The average indoor PM2.5 concentrations in nine compliant venues significantly decreased to 18 microg/m3 one week after the law took effect. Three venues having 82 microg/m3 before the law had significantly lower levels from the first day the law was implemented, and the low level was maintained. Compliance with the law is critical to achieving clean indoor air. Indoor air pollution in the bingo hall was not reduced until the establishment decided to comply with the law. The smoke-free law showed immediate impact on indoor air quality.

  19. VOC SAMPLING IN THE WATER TABLE/CAPILLARY FRINGE AREA FOR ASSESSING IMPACT ON VAPOR INTRUSION AND INDOOR AIR QUALITY

    Science.gov (United States)

    Vapor intrusion has been determined to be a major pathway for increased indoor air contamination from volatile organic contaminants (VOCs) at certain contaminated sites. In order to properly assess vapor intrusion, it is important to adequately evaluate VOC concentrations in the...

  20. Indoor radon monitoring in the Mandi district of Himachal Pradesh, India, for health hazard assessment

    International Nuclear Information System (INIS)

    Kumar, G.; Kumar, A.; Walia, V.; Kumar, M.; Tuccu, M.A.; Prasher, S.

    2016-01-01

    In the present study, indoor radon equilibrium equivalent concentration monitoring was carried out using Solid-State Nuclear Track Detectors in some residential areas of the Mandi district, Himachal Pradesh, India. The average value of the indoor radon equilibrium equivalent concentration in the study area was found to be 94 Bq m -3 , with an annual effective dose of 1.61 mSv. The average value of the indoor radon equilibrium equivalent concentration in the studied areas was found to be higher than the world average indoor radon value of 40 Bq m -3 but lower than the value of the action level 300 Bq m -3 , except for two locations. (authors)

  1. Indoor human exposure to size-fractionated aerosols during the 2015 Southeast Asian smoke haze and assessment of exposure mitigation strategies

    Science.gov (United States)

    Sharma, Ruchi; Balasubramanian, Rajasekhar

    2017-11-01

    The 2015 smoke haze episode was one of the most severe and prolonged transboundary air pollution events ever seen in Southeast Asia (SEA), affecting the air quality of several countries within the region including Indonesia, Malaysia and Singapore. The 24 h mean outdoor PM2.5 (particulate matter (PM) with aerodynamic diameter ≤ 2.5 μm) concentrations ranged from 72-157 μg m-3 in Singapore during this episode, exceeding the WHO 24 h mean PM2.5 guidelines (25 μg m-3) several times over. The smoke haze episode not only affected ambient air quality, but also indoor air quality due to the migration of PM of different sizes from the outdoor to the indoor environment. Despite the frequent occurrence of smoke haze episodes over the years, their potential health impacts on indoor building occupants remain largely unknown in SEA due to the lack of systematic investigations and observational data. The current work was carried out in Singapore to assess human exposure to size-resolved PM during the 2015 smoke haze episode, and to evaluate the effectiveness of exposure mitigation measures in smoke-haze-impacted naturally ventilated indoor environments. The potential health risks associated with exposure to PM2.5 were assessed based on the concentrations of redox active particulate-bound trace elements, which are known to be harmful to human health, with and without exposure mitigation. Overall, it was observed that human health exposure to PM2.5 and its carcinogenic chemical components was reduced substantially by 62% (p health.

  2. A View Indoors, Indoor Environment Division's e-Article Series

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  3. EPA (Environmental Protection Agency) Indoor-Air Quality Implementation Plan. A report to Congress under Title IV of the Superfund Amendments and Reauthorization Act of 1986: radon gas and indoor air-quality research. Final report

    International Nuclear Information System (INIS)

    1987-06-01

    The EPA Indoor Air Quality Implementation Plan provides information on the direction of EPA's indoor air program, including the Agency's policy on indoor air and priorities for research and information dissemination over the next two years. EPA submitted the report to Congress on July 2, 1987 as required by the Superfund Amendments and Reauthorization Act of 1986. There are five appendices to the report: Appendix A--Preliminary Indoor Air Pollution Information Assessment; Appendix B--FY 87 Indoor Air Research Program; Appendix C--EPA Radon Program; Appendix D--Indoor Air Resource History (Published with Appendix C); Appendix E--Indoor Air Reference Data Base

  4. Assessment of the biomass related indoor air pollution in Kwale district in Kenya using short term monitoring.

    Science.gov (United States)

    Majdan, Marek; Svaro, Miroslav; Bodo, Jan; Taylor, Mark; Muendo, Redempta Malinda

    2015-09-01

    Indoor air pollution remains an important health problem in some countries. Although research data on this issue is available, routine monitoring in affected areas is limited. The aims of this study were to quantify exposure to biomass-related indoor air pollution; assess the respiratory health of subjects; and explore the feasibility of routine monitoring in Kwale district, Kenya. We sampled 125 rural houses using short-term monitoring for levels of CO, CO2 and TSP. Additional exposure information was obtained using a checklist. Respiratory health was also assessed using a questionnaire, and electronic spirometer in 172 inhabitants. The overall median levels of CO in the sampled houses on all study sites ranged from 5.9 (IQR 3-14.5) to 10 (5.5-21.2) mg/m3, levels of CO2 ranged from 774 (IQR 724-846) to 839 (IQR 749-961) mg/m3) and the levels of TSP ranged from 295 (IQR 79-853 to 1384 (IQR 557-3110) µg/m(3) which indicates that safe levels recommended by WHO and USEPA could be exceeded. Relatively high incidences of respiratory illness or symptoms were reported and the spirometry readings suggested impaired lung function in over 80% of respondents. Our results quantify that the use of biomass fuel can give rise to high levels of indoor air pollution. Given that poor lung function contributes to public health problems in rural regions of East Africa, such as Kwale in Kenya, our findings create grounds for more detailed investigations of the problem and may provide motivation for community based interventions.

  5. Model for the assessment of surface radionuclide 210 Pb contamination indoors due to presence of radon

    International Nuclear Information System (INIS)

    Mrdja, D.; Bikit, I.; Forkapic, S.

    2009-01-01

    The model is based on the fact that the change of indoor radon concentration, which periodically enters the room, affects only on radioactive decay and the inserted amount of radon in each impact, but not on its diffusion out, i.e. escape from the room. The aim of the model is to assess the surface contamination of the room by lead 210 Pb. (author) [sr

  6. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  7. Spatial models for context-aware indoor navigation systems: A survey

    Directory of Open Access Journals (Sweden)

    Imad Afyouni

    2012-06-01

    Full Text Available This paper surveys indoor spatial models developed for research fields ranging from mobile robot mapping, to indoor location-based services (LBS, and most recently to context-aware navigation services applied to indoor environments. Over the past few years, several studies have evaluated the potential of spatial models for robot navigation and ubiquitous computing. In this paper we take a slightly different perspective, considering not only the underlying properties of those spatial models, but also to which degree the notion of context can be taken into account when delivering services in indoor environments. Some preliminary recommendations for the development of indoor spatial models are introduced from a context-aware perspective. A taxonomy of models is then presented and assessed with the aim of providing a flexible spatial data model for navigation purposes, and by taking into account the context dimensions.

  8. Report. no. 20. Sensory evaluation of indoor air quality

    DEFF Research Database (Denmark)

    Berglund, Birgitta; Bluyssen, Philomena; Clausen, Geo

    Human subjects are indispensable in the measurement of perceived indoor air quality. Chemical and physical methods of characterisation often are insensitive to odorous and sensory irritating air pollutants, or do not take account of combinations of singular pollutants in a biologically meaningful...... way. Therefore, sensory methods many times are the only or the preferred tool for evaluation of perceived indoor air quality. This report presents background to and advice on methodologies for sensory evaluation of perceived indoor air quality. It proposes methods which apply to source assessments...... as well as field investigations. The methods will assist in labelling of building materials, characterising air quality in indoor spaces, controlling ventilation performance, and measuring occupant responses in questionnaire field studies of the sick building syndrome. The proposed methods will enable...

  9. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    Science.gov (United States)

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  10. Life time fatality risk assessment due to variation of indoor radon concentration in dwellings in western Haryana, India

    International Nuclear Information System (INIS)

    Kansal, Sandeep; Mehra, Rohit; Singh, N.P.

    2012-01-01

    Indoor radon measurements in 60 dwellings belonging to 12 villages of Sirsa, Fatehbad and Hisar districts of western Haryana, India, have been carried out, using LR-115 type II cellulose nitrate films in the bare mode. The annual average indoor radon value in the studied area varies from 76.00 to 115.46 Bq m −3 , which is well within the recommended action level 200–300 Bq m −3 (). The winter/summer ratio of indoor radon ranges from 0.78 to 2.99 with an average of 1.52. The values of annual average dose received by the residents and Life time fatality risk assessment due to variation of indoor radon concentration in dwellings of studied area suggests that there is no significance threat to the human beings due to the presence of natural radon in the dwellings. - Highlights: ► The radon concentration values in the dwellings are 2–3 times more than the world average of 40 Bq m −3 . ► These values are lower than the recommended action level of 200–300 Bq m −3 (). ► The annual effective dose is less than the recommended action level of 3–10 mSv per year (). ► The values of life time fatality risk determined for the studied area are within safe standards. ► There is no significant threat to the human beings due to the presence of natural radon in the dwellings.

  11. Indoor/Outdoor Air Quality Assessment at School near the Steel Plant in Taranto (Italy

    Directory of Open Access Journals (Sweden)

    A. Di Gilio

    2017-01-01

    Full Text Available This study aims to investigate the air quality in primary school placed in district of Taranto (south of Italy, an area of high environmental risk because of closeness between large industrial complex and urban settlement. The chemical characterization of PM2.5 was performed to identify origin of pollutants detected inside school and the comparison between indoor and outdoor levels of PAHs and metals allowed evaluating intrusion of outdoor pollutants or the existence of specific indoor sources. The results showed that the indoor and outdoor levels of PM2.5, BaP, Cd, Ni, As, and Pb never exceeded the target values issued by World Health Organization (WHO. Nevertheless, high metals and PAHs concentrations were detected especially when school were downwind to the steel plant. The I/O ratio showed the impact of outdoor pollutants, especially of industrial markers as Fe, Mn, Zn, and Pb, on indoor air quality. This result was confirmed by values of diagnostic ratio as B(aP/B(gP, IP/(IP + BgP, BaP/Chry, and BaP/(BaP + Chry, which showed range characteristics of coke and coal combustion. However, Ni and As showed I/O ratio of 2.5 and 1.4, respectively, suggesting the presence of indoor sources.

  12. Strength of smoke-free air laws and indoor air quality.

    Science.gov (United States)

    Lee, Kiyoung; Hahn, Ellen J; Robertson, Heather E; Lee, Seongjik; Vogel, Suzann L; Travers, Mark J

    2009-04-01

    Smoke-free air laws have been implemented in many Kentucky communities to protect the public from the harmful effects of secondhand smoke exposure. The impact of different strengths of smoke-free air laws on indoor air quality was assessed. Indoor air quality in hospitality venues was assessed in seven communities before and after comprehensive smoke-free air laws and in two communities only after partial smoke-free air laws. One community was measured three times: before any smoke-free air law, after the initial partial law, and after the law was strengthened to cover all workplaces and public places with few exemptions. Real-time measurements of particulate matters with 2.5 mum aerodynamic diameter or smaller (PM(2.5)) were obtained. When comprehensive smoke-free air laws were implemented, indoor PM(2.5) concentrations decreased significantly from 161 to 20 microg/m3. In one community that implemented a comprehensive smoke-free law after initially passing a partial law, indoor PM(2.5) concentrations were 304 microg/m3 before the law, 338 microg/m3 after the partial law, and 9 microg/m3 after the comprehensive law. The study clearly demonstrated that partial smoke-free air laws do not improve indoor air quality. A significant linear trend indicated that PM(2.5) levels in the establishments decreased with fewer numbers of burning cigarettes. Only comprehensive smoke-free air laws are effective in reducing indoor air pollution from secondhand tobacco smoke.

  13. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  14. Indoor Air Pollutant Exposure for Life Cycle Assessment: Regional Health Impact Factors for Households

    DEFF Research Database (Denmark)

    Rosenbaum, Ralph K.; Meijer, Arjen; Demou, Evangelia

    2015-01-01

    of magnitude, due to the variability of ventilation rate, building occupation, and volume. To compare health impacts as a result of indoor exposure with those from outdoor exposure, the indoor exposure characterization factors determined with the modified USEtox model were applied in a case study on cooking...

  15. Indoor Tanning

    Science.gov (United States)

    ... proof that indoor tanning is safer than tanning outdoors. Indoor tanning systems give concentrated UV exposure regardless ... For example, it’s essential for promoting good bone health. While UV ... a tan to get that benefit. According to the Surgeon General, fair and light- ...

  16. Contribution of 222Rn-bearing water to indoor radon and indoor air quality assessment in hot spring hotels of Guangdong, China

    International Nuclear Information System (INIS)

    Song Gang; Wang Xinming; Chen Diyun; Chen Yongheng

    2011-01-01

    This study investigates the contribution of radon ( 222 Rn)-bearing water to indoor 222 Rn in thermal baths. The 222 Rn concentrations in air were monitored in the bathroom and the bedroom. Particulate matter (PM, both PM 10 and PM 2.5 ) and carbon dioxide (CO 2 ) were also monitored with portable analyzers. The bathrooms were supplied with hot spring water containing 66-260 kBq m -3 of 222 Rn. The results show that the spray of hot spring water from the bath spouts is the dominant mechanism by which 222 Rn is released into the air of the bathroom, and then it diffuses into the bedroom. Average 222 Rn level was 110-410% higher in the bedrooms and 510-1200% higher in the bathrooms compared to the corresponding average levels when there was no use of hot spring water. The indoor 222 Rn levels were influenced by the 222 Rn concentrations in the hot spring water and the bathing times. The average 222 Rn transfer coefficients from water to air were 6.2 x 10 -4 -4.1 x 10 -3 . The 24-h average levels of CO 2 and PM 10 in the hotel rooms were 89% and 22% higher than the present Indoor Air Quality (IAQ) standard of China. The main particle pollutant in the hotel rooms was PM 2.5 . Radon and PM 10 levels in some hotel rooms were at much higher concentrations than guideline levels, and thus the potential health risks to tourists and especially to the hotel workers should be of great concern, and measures should be taken to lower inhalation exposure to these air pollutants. - Highlights: → 222 Rn-bearing water is the main contributor to indoor radon in hot spring hotel. → The PM 2.5 and CO 2 are also the main indoor pollutants in the hotel rooms. → Higher radon and PM levels might have significant negative health effects to human. → The radon transfer coefficients are consistent with the published data.

  17. Perceived indoor environment and occupants’ comfort in European “Modern” office buildings: The OFFICAIR Study

    NARCIS (Netherlands)

    Sakellaris, I.A.; Saraga, D.E.; Mandin, C.; Roda, C.; Fossati, S.; Kluizenaar, Y. de; Carrer, P.; Dimitroulopoulou, S.; Mihucz, V.G.; Szigeti, T.; Hänninen, O.; Oliveira Fernandes, E. de; Bartzis, J.G.; Bluyssen, P.M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to

  18. Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study.

    Science.gov (United States)

    Mandin, Corinne; Trantallidi, Marilena; Cattaneo, Andrea; Canha, Nuno; Mihucz, Victor G; Szigeti, Tamás; Mabilia, Rosanna; Perreca, Erica; Spinazzè, Andrea; Fossati, Serena; De Kluizenaar, Yvonne; Cornelissen, Eric; Sakellaris, Ioannis; Saraga, Dikaia; Hänninen, Otto; De Oliveira Fernandes, Eduardo; Ventura, Gabriela; Wolkoff, Peder; Carrer, Paolo; Bartzis, John

    2017-02-01

    The European project OFFICAIR aimed to broaden the existing knowledge regarding indoor air quality (IAQ) in modern office buildings, i.e., recently built or refurbished buildings. Thirty-seven office buildings participated in the summer campaign (2012), and thirty-five participated in the winter campaign (2012-2013). Four rooms were investigated per building. The target pollutants were twelve volatile organic compounds, seven aldehydes, ozone, nitrogen dioxide and particulate matter with aerodynamic diameter indoor air concentrations of formaldehyde and ozone did not exceed their respective WHO air quality guidelines, and those of acrolein, α-pinene, and d-limonene were lower than their estimated thresholds for irritative and respiratory effects. PM 2.5 indoor concentrations were higher than the 24-h and annual WHO ambient air quality guidelines. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Enabling Indoor Location-Based Services

    DEFF Research Database (Denmark)

    Radaelli, Laura

    Indoor spaces have always attracted interest from different scientific disciplines. Relatively recent interest in indoor settings by computer scientists is driven in part by the increasing use of smartphones, which serve as a platform for service delivery and can generate extensive volumes...... of trajectory data that can be used to study how people actually use indoor spaces. In this dissertation, we contribute partial solutions that address challenges in indoor positioning and indoor trajectory management and analysis. The key enabler of indoor location-based services and indoor movement analysis...... is a well-functioning positioning system that can be easily deployed in most public places. Different technologies are able to provide indoor positioning with different accuracy and coverage, but it is difficult to find a technology that by itself can provide good positioning in the many different layouts...

  20. 41 CFR 102-80.25 - What are Federal agencies' responsibilities concerning the management of indoor air quality?

    Science.gov (United States)

    2010-07-01

    ... agencies' responsibilities concerning the management of indoor air quality? 102-80.25 Section 102-80.25... Environmental Management Indoor Air Quality § 102-80.25 What are Federal agencies' responsibilities concerning the management of indoor air quality? Federal agencies must assess indoor air quality of buildings as...

  1. Supporting Indoor Navigation Using Access Rights to Spaces Based on Combined Use of IndoorGML and LADM Models

    Directory of Open Access Journals (Sweden)

    Abdullah Alattas

    2017-11-01

    of this paper. The main purpose of the combined use model is to support the indoor navigation, but could also support different applications, such as the maintenance and facility management work, by computing the cleaning cost based on the space floor area. The main contributions of this paper are: a solution for the combined use of IndoorGML-LADM model, a conceptual enhancement of LADM by the refinement of the LA_Party package with specialization for staff and student (groups, and the assessment of the model by converting sample data (from two complex university buildings into the model, and conducting actual access-rights aware navigation, based on the populated model.

  2. ["Assessment of indoor school environment and identification of measures to protect the respiratory health of school children and adolescents" in a sample of schools in Milan].

    Science.gov (United States)

    Piazza, S; Gulino, A; Pulvirenti, S; Vercelli, F; Carrer, P

    2012-01-01

    The management of indoor air quality in schools needs special attention because it has a strong impact on respiratory health of children with effects also on performance and social development. In Italy a prevention program for indoor environments is provided in the "Guidelines for the prevention of indoor risk factors for allergies and asthma in the school", developed by the Ministry of Health (G.U n. 9 del 13.01.11). In this context, the Ministry of Health has promoted the "Indoor school" project (CCM2010). The main objective of the project is the implementation of these guidelines. In this paper we report the results of the first phase of the project which assessed the knowledge of school principals on issues related to IAQ and building characteristics of the school.

  3. Conference particulate matter and indoor environment, I.N.E.R.I.S.; Particulate matter and indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Comprehensive characterisation of indoor and outdoor air as well as pollution emission sources Integrated health and environmental risk assessment Scientific and technical basis for airborne pollution management and control Fine and coarse particles. The sources of indoor air pollution are originate separately, are transported separately, are removed from atmosphere by different mechanisms, have different optical properties, have different chemical properties, require different control techniques. for the health effects due to particles, they decrease the lung function, increase respiratory symptoms, increase chronic obstructive pulmonary diseases, increased cardiovascular disease, increased mortality. The different sources contributing to the highest concentrations are: concentrations: tobacco smoking, cooking, vacuuming, dusting and sweeping, heaters, stoves, fireplaces and some other non identified sources. In the future we want more focus on fine and ultra fine particles, investigate source apportionment of particles, better understanding and quantification of exposure, to implement guidelines for particle concentration in indoor air and find better cleaning technologies. (N.C.)

  4. Indoor air in school environment and the impact on children’s health

    International Nuclear Information System (INIS)

    Krajcova, D.; Vondrova, D.; Hirosova, K.; Sevcikova, L.

    2014-01-01

    More attention is paid to assessing the quality of not only outdoor but also indoor air. Since children spend large part of their time at schools, several studies are aimed at indoor air monitoring in schools. These studies confirmed association between poor quality of indoor environment and the incidence of asthma and other respiratory diseases of children. The most serious indoor air pollutants includes dust particles, inorganic and volatile organic compounds, components of tobacco smoke, mold and dust mites. Providing healthy school environment should be one of the basic methods to protect and support physical and mental health and development of children. (author)

  5. Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran

    Science.gov (United States)

    Hazrati, Sadegh; Rostami, Roohollah; Farjaminezhad, Manoochehr; Fazlzadeh, Mehdi

    2016-05-01

    BTEX concentrations in indoor and outdoor air of 50 homes were studied in Ardabil city and their influencing parameters including; heating system, using gas stove and samovar, tobacco smoking, the floors in which the monitored homes were located, and kitchen plan were considered in the study. Risk assessment analysis was carried out with the obtained concentrations based on EPA IRIS reference doses. BTEX compounds were sampled by charcoal tubes and the samples were analyzed by a GC-FID. Concentrations of benzene (15.18 μg/m3 vs. 8.65 μg/m3), toluene (69.70 μg/m3 vs. 40.56 μg/m3), ethylbenzene (12.07 μg/m3 vs. 4.92 μg/m3) and xylene (48.08 μg/m3 vs. 7.44 μg/m3) in indoor air were significantly (p < 0.05) higher than the levels quantified for outdoor air. The obtained concentrations of benzene were considerably higher than the recommended value of 5 μg/m3 established by Iran environmental protection organization. Among the BTEX compounds, benzene (HQ = 0.51) and xylene (HQ = 0.47) had notable hazard quotient and were the main pollutants responsible for high hazard index in the monitored homes (HI = 1.003). The results showed considerably high cancer risk for lifetime exposure to the indoor (125 × 10-6) and outdoor (71 × 10-6) benzene. Indoor benzene concentrations in homes were significantly influenced by type of heating system, story, and natural gas appliances.

  6. The Relationships Between Female Adolescents' Media Use, Indoor Tanning Outcome Expectations, and Behavioral Intentions.

    Science.gov (United States)

    Myrick, Jessica Gall; Noar, Seth M; Kelley, Dannielle; Zeitany, Alexandra E

    2017-06-01

    Unlike other types of cancer, skin cancer incidence rates are on the rise and adolescent females are particularly likely to tan indoors, a major risk factor. However, little research has examined the role of media use in encouraging or discouraging this dangerous behavior in this population. To empirically assess the links between media use, indoor tanning-related outcome expectations, and behavioral intentions. A survey of adolescent females ( N = 510) ages 15 to 18 in the Southeastern United States assessed demographics, types of media use, and indoor tanning intentions. Significant correlations between media use and indoor tanning outcome expectations were found. Use of interpersonal and social media (i.e., talking on the phone, texting, and online social media) were positively associated with positive outcome expectations about indoor tanning and negatively associated with negative outcome expectations. A path analysis revealed that interpersonal/social media use had indirect associations with indoor tanning intentions via tanning outcome expectations. Mass media use (e.g., news media, entertainment media, and magazines) was not significantly associated with most indoor tanning outcome expectations but did have a direct negative association with behavioral intentions. There are important relationships between media use, indoor tanning outcome expectations, and behavioral intentions. Interpersonal and social media use may help cultivate outcome expectations that encourage indoor tanning, which in turn may increase intentions to tan, while news media consumption in particular may reduce intentions to tan. These findings highlight the social nature of adolescent females and point to specific intervention channels for reducing indoor tanning among this population.

  7. ASSESSMENT OF THE INDOOR ENVIRONMENT AND IMPLICATIONS FOR HEALTH IN ROMA VILLAGES IN SLOVAKIA AND ROMANIA

    Science.gov (United States)

    Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš

    2013-01-01

    SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520

  8. Towards Mobile Information Systems for Indoor Space

    Directory of Open Access Journals (Sweden)

    Xiaoxiang Zhang

    2016-01-01

    Full Text Available With the rapid development of Internet of things (IOT and indoor positioning technologies such as Wi-Fi and RFID, indoor mobile information systems have become a new research hotspot. Based on the unique features of indoor space and urgent needs on indoor mobile applications, in this paper we analyze some key issues in indoor mobile information systems, including positioning technologies in indoor environments, representation models for indoor spaces, query processing techniques for indoor moving objects, and index structures for indoor mobile applications. Then, we present an indoor mobile information management system named IndoorDB. Finally, we give some future research topics about indoor mobile information systems.

  9. Indoor Radon and Its Decay Products: Concentrations, Causes, and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-01-01

    This report is an introduction to the behavior of radon 222 and its decay products in indoor air. This includes review of basic characteristics of radon and its decay products and of features of the indoor environment itself, all of which factors affect behavior in indoor air. The experimental and theoretical evidence on behavior of radon and its decay products is examined, providing a basis for understanding the influence of geological, structural, and meteorological factors on indoor concentrations, as well as the effectiveness of control techniques. We go on to examine three important issues concerning indoor radon. We thus include (1) an appraisal of the concentration distribution in homes, (2) an examination of the utility and limitations of popular monitoring techniques and protocols, and (3) an assessment of the key elements of strategies for controlling radon levels in homes.

  10. Evolution of the indoor biome.

    Science.gov (United States)

    Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R

    2015-04-01

    Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  12. Dermal Uptake of Organic Vapors Commonly Found in Indoor Air

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Nazaroff, William W

    2014-01-01

    Transdermal uptake directly from air is a potentially important yet largely overlooked pathway for human exposure to organic vapors indoors. We recently reported (Indoor Air 2012, 22, 356) that transdermal uptake directly from air could be comparable to or larger than intake via inhalation for many......, formaldehyde, and acrolein. Analysis of published experimental data for human subjects for twenty different organic compounds substantiates these model predictions. However, transdermal uptake rates from air have not been measured for the indoor organics that have the largest modeled ratios of dermal......-to-inhalation uptake; for such compounds, the estimates reported here require experimental verification. In accounting for total exposure to indoor organic pollutants and in assessing potential health consequences of such exposures, it is important to consider direct transdermal absorption from air....

  13. Assessment of indoor and outdoor airborne fungi in an Educational, Research and Treatment Center

    Directory of Open Access Journals (Sweden)

    Nasrin Rostami

    2016-06-01

    Full Text Available Hospital environments contain different types of microorganisms. Airborne fungi are one of these microbes and the major source of hospital indoor contamination that will be able to cause airborne fungal diseases. In the current study, the total count and diversity of the airborne filamentous and yeasts fungi were investigated in indoor and outdoor air of selective wards of Emam Reza Educational, Research and Treatment Center. This cross-sectional study was performed during the fall season. One hundred and ninety-two environmental samples of indoor and outdoor air from hematology, infectious diseases, Ear, Nose and Throat (ENT and Neonatal Intensive Care Unit (NICU wards were collected by open plate technique (on Sabouraud dextrose agar media once a week. The cultures were then examined and evaluated according to macroscopic and microscopic examination criteria. In this study, 67 (62.03% of indoor samples and 81 (96.42% of outdoor samples were positive for fungi. The most isolated fungi were yeast species (17.12%, Penicillium spp. (16.34%, Alternaria spp. (14.39%, Aspergillus niger (11.28%, A. flavus (8.95%, respectively. Almost all of the wards showed high rates of contamination by various fungi. However, the analysis of the data showed that indoor air of hematology ward had the highest fungal pollution. In contrast, the outdoor air of ENT had the highest fungal pollution. Thus, these results demonstrated that the cleansing and disinfection procedures in the hospital wards should be improved yet.

  14. Indoor climate design for a monumental building with incidental high indoor moisture loads

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2005-01-01

    The paper presents a study of the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated and evaluated. The results include the influence of hygric inertia on the indoor climate and

  15. Occurrence, dynamics and reactions of organic pollutants in the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Salthammer, Tunga [Material Analysis and Indoor Chemistry, Fraunhofer Wilhelm-Klauditz Institut (WKI), Braunschweig (Germany); Bahadir, Muefit [Institut fuer Oekologische Chemie und Abfallanalytik, Technische Universitaet Braunschweig, Braunschweig (Germany)

    2009-06-15

    The indoor environment is a multidisciplinary scientific field involving chemistry, physics, biology, health sciences, architecture, building sciences and civil engineering. The need for reliable assessment of human exposure to indoor pollutants is attracting increasing attention. This, however, requires a detailed understanding of the relevant compounds, their sources, physical and chemical properties, dynamics, reactions, their distribution among the gas phase, airborne particles and settled dust as well as the availability of modern measurement techniques. Building products, furnishings and other indoor materials often emit volatile and semi-volatile organic compounds. With respect to a healthy indoor environment, only low emitting products, which do not influence indoor air quality in a negative way, should be used in a building. Therefore, materials and products for indoor use need to be evaluated for their chemical emissions. This is routinely done in test chambers and cells. Many studies have shown that the types of sources in occupational and residential indoor environments, the spectrum of emitting compounds and the duration of emission cover a wide range. The demand for standardized test methods under laboratory conditions has resulted in several guidelines for determination of emission rates. Furthermore, it has now been recognized that both primary and secondary emissions may affect indoor air quality. The problem may become more dominant when components of different materials can react with each other or when catalytic materials are applied. Such products derived from indoor related reactions may have a negative impact on indoor air quality due to their low odor threshold, health related properties or the formation of ultrafine particles. Several factors can influence the emission characteristics and numerous investigations have shown that indoor chemistry is of particular importance for the indoor related characterization of building product emissions

  16. Strategies to determine and control the contributions of indoor air pollution to total inhalation exposure (STRATEX)

    DEFF Research Database (Denmark)

    Cochet, C.; Fernandes, E.O.; Jantunen, M.

    ECA-IAQ (European Collaborative Action, Urban Air, Indoor Environment and Human Exposure), 2006. Strategies to determine and control the contributions of indoor air pollution to total inhalation exposure (STRATEX), Report No 25. EUR 22503 EN. Luxembourg: Office for Official Publications...... of the European Communities It is now well established that indoor air pollution contributes significantly to the global burden of disease of the population. Therefore, the knowledge of this contribution is essential in view of risk assessment and management. The ECA STRATEX report collates the respective...... information and describes the strategies to determine population exposure to indoor air pollutants. Its major goal is to emphasise the importance of the contribution of indoor air to total air exposure. Taking this contribution into account is a prerequisite for sound risk assessment of air pollution...

  17. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances.

    Science.gov (United States)

    Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A; Al-Khalifa, Hend S

    2016-05-16

    In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.

  18. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances

    Directory of Open Access Journals (Sweden)

    Abdulrahman Alarifi

    2016-05-01

    Full Text Available In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.

  19. The Health Risks of Belgian Illicit Indoor Cannabis Plantations.

    Science.gov (United States)

    Vanhove, Wouter; Cuypers, Eva; Bonneure, Arne-Jan; Gotink, Joachim; Stassen, Mirna; Tytgat, Jan; Van Damme, Patrick

    2018-04-10

    We assessed the prevalence of potential health hazards to intervention staff and cannabis growers in Belgian indoor cannabis plantations. Surface mold swab samples were taken at 16 Belgian indoor plantations contained mostly Penicillium sp. and Aspergillus sp. However, their precise health impact on intervention staff and illicit growers is unclear as no molds spore concentrations were measured. Atmospheric gas monitoring in the studied cannabis plantations did not reveal dangerous toxic substances. Health symptoms were reported by 60% of 221 surveyed police, but could not be linked to specific plantation characteristics. We conclude that Belgian indoor cannabis plantations pose a potential health threat to growers and intervention staff. AS there are currently no clear safety guidelines for seizure and dismantling of Belgian indoor cannabis plantations, we recommend first responders to follow strict safety rules when entering the growth rooms, which include wearing appropriate personal protective equipment. © 2018 American Academy of Forensic Sciences.

  20. Current Indoor Air Quality in Japan.

    Science.gov (United States)

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  1. Health Risk Assessment of Indoor Air Quality, Socioeconomic and House Characteristics on Respiratory Health among Women and Children of Tirupur, South India

    Directory of Open Access Journals (Sweden)

    Krassi Rumchev

    2017-04-01

    Full Text Available Background: Indoor air pollution is still considered as one of the leading causes of morbidity and mortality worldwide and especially in developing countries, including India. This study aims to assess social, housing, and indoor environmental factors associated with respiratory health among mothers and children. Methods: The study was conducted in the city of Tirupur, South India. We quantitatively assessed the indoor exposure to fine particulate matter (PM2.5 and carbon monoxide in relation to respiratory health among women and children. Information on health status, household characteristics and socioeconomic factors was collected using a modified standardised questionnaire. Results: This study demonstrates the significant health impact of housing and socioeconomic characteristics on the burden of respiratory illness among women and children in urban South India. Increased respiratory symptoms were recorded among women and children from low income households, and those who allowed smoking inside. The mean PM2.5 concentration measured in this study was 3.8 mg/m3 which exceeded the World Health Organization (WHO 24 h guideline value of 0.025 mg/m3. Conclusions: This study is the first to our knowledge carried out in urban South India and the findings can be used for future intervention studies.

  2. Occurrence, sources and human exposure assessment of SCCPs in indoor dust of northeast China.

    Science.gov (United States)

    Liu, Li-Hua; Ma, Wan-Li; Liu, Li-Yan; Huo, Chun-Yan; Li, Wen-Long; Gao, Chong-Jing; Li, Hai-Ling; Li, Yi-Fan; Chan, Hing Man

    2017-06-01

    Short-chain chlorinated paraffins (SCCPs) are widely used chemicals in household products and might cause adverse human health effects. However, limited information is available on the occurrence of SCCPs in indoor environments and their exposure risks on humans. In this study the concentrations, profiles and human exposure of SCCPs in indoor dust from five different indoor environments, including commercial stores, residential apartments, dormitories, offices and laboratories were characterized. The SCCPs levels ranged from 10.1 to 173.0 μg/g, with the median and mean concentration of 47.2 and 53.6 μg/g, respectively. No significant difference was found on concentrations among the five microenvironments. The most abundant compounds in indoor dust samples were homologues of C 13 group, Cl 7 group and N 20 (N is the total number of C and Cl) group. In the five microenvironments, commercial stores were more frequently exposed to shorter carbon chained and higher chlorinated homologues. Three potential sources for SCCPs were identified by the multiple linear regression of factor score model and correspondence analysis. The major sources of SCCPs in indoor dust were technical mixtures of CP-42 (42% chlorine, w/w) and CP-52 b (52% chlorine, w/w). The total daily exposure doses and hazard quotients (HQ) were calculated by the human exposure models, and they were all below the reference doses and threshold values, respectively. Monte Carlo simulation was applied to predict the human exposure risk of SCCPs. Infants and toddlers were at risk of SCCPs based on predicted HQ values, which were exceeded the threshold for neoplastic effects in the worst case. Our results on the occurrences, sources and human exposures of SCCPs will be useful to provide a better understanding of SCCPs behaviors in indoor environment in China, and to support environmental risk evaluation and regulation of SCCPs in the world. Copyright © 2017. Published by Elsevier Ltd.

  3. Microbiological assessment of indoor air of a teaching hospital in Nigeria.

    Science.gov (United States)

    Awosika, S A; Olajubu, F A; Amusa, N A

    2012-06-01

    To investigate the quality of indoor air of different wards and units of Olabisi Onabanjo University Teaching Hospital, Sagamu, to ascertain their contribution to infection rate in the hospital. The microbial quality of indoor air of nine wards/units of Olabisi Onabanjo University Teaching Hospital, Sagamu, Nigeria was conducted. Sedimentation technique using open Petri-dishes containing different culture media was employed and samplings were done twice daily, one in the morning shortly after cleaning and before influx of people/patients into the wards/units and the other in the evening when a lot of activities would have taken place in these wards. Isolates were identified according to standard methods. Results showed that there was a statistically significant difference (χ(2) = 6.016 7) in the bacteria population of the different sampling time whereas it was not so for fungi population (χ(2) = 0.285 7). Male medical ward (MMW) and male surgical general (MSG) recorded the highest bacterial and fungal growth while the operating theatre (OT) was almost free of microbial burden. The bacteria isolates were Staphylococcus aureus, Klebsiella sp., Bacillus cereus, Bacillus subtilis, Streptococcus pyogenes and Serratia marscences while the fungi isolates included Aspergillus flavus, Penicillium sp., Fusarium sp., Candida albicans and Alternaria sp. Staphylococcus aureus was the predominantly isolated bacterium while Penicillium sp. was the most isolated fungus. Though most of the microbial isolates were potential and or opportunistic pathogens, there was no correlation between the isolates in this study and the surveillance report of nosocomial infection during the period of study, hence the contribution of the indoor air cannot be established. From the reduction noticed in the morning samples, stringent measures such as proper disinfection and regular cleaning, restriction of patient relatives' movement in and out of the wards/units need to be enforced so as to

  4. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  5. Environmental assessments on schools located on or near former industrial facilities: Feedback on attenuation factors for the prediction of indoor air quality.

    Science.gov (United States)

    Derycke, Virginie; Coftier, Aline; Zornig, Clément; Léprond, Hubert; Scamps, Mathilde; Gilbert, Dominique

    2018-06-01

    One of the goals of the French national campaign called "Etablissements Sensibles (Sensitive Establishments)" is to evaluate indoor air degradation in schools because of vapor intrusion of volatile compounds from soil gases towards the indoor air, related to the presence of former industrial sites on or near the establishment. During this campaign, as recommended by the United States of Environmental Protection Agency (US EPA), indoor air quality was evaluated from soil gas concentrations using generic attenuation factors, and extra investigations into soil gases and indoor air were performed when the estimated values exceeded target indoor air concentrations. This study exploits matched data on subsurface soil gases and indoor air that came from the "Sensitive Establishments" campaign. It aims to consolidate and refine the use of attenuation factors as a function of environmental variables acquired routinely during environmental assessments. We have been able to select the measured environmental variables that have the most influence on vapor intrusion using Principal Components Analysis and hypotheses tests. Since the collected data are mainly related to weak sources (only 15% schools required risk management measures related to vapor intrusion), halogenated volatile organic compounds (HVOC) were selected as tracer compounds for vapor intrusion for this study. This choice enables the exclusion or minimization of background sources contributions. From the results we have calculated the descriptive statistics of the attenuation factors distribution for the subslab-to-indoor air pathway and refined the attenuation factors for this pathway through an easily obtained parameter, building age. Qualitative comparison of attenuation factors according to the building age shows that attenuation factors observed for building less than 50 years are lower than attenuation factors for buildings 50 years old and above. These results show the utility of creating databases for

  6. Indoor air quality : Tools for schools action kits for Canadian schools

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    Few people realize that indoor air pollution can contribute to health effects like asthma. Several agencies, notably the United States Environmental Protection Agency (EPA), have indicated that levels of indoor pollutants can be significantly higher than those found outside. As such, poor indoor air quality (IAQ) could impact the health of students and staff, as well as the educational process and costs. Many factors can influence IAQ, including building materials, furnishings, cleaning agents, pesticides, printing and copying devices, and more. Reduction in IAQ can also result from tighter buildings and reduced ventilation. This kit was developed by Health Canada in collaboration with the Indoor Air Quality Working Group of the Federal-Provincial-Territorial Committee on Environmental and Occupational Health (CEOH) to provide school officials with the tools to prevent, identify, assess, and address most indoor air problems while minimizing cost and involvement. It was suggested that trained professionals should perform the limited and well-defined set of operations and maintenance activities described in the kit.

  7. Very volatile organic compounds: an understudied class of indoor air pollutants.

    Science.gov (United States)

    Salthammer, T

    2016-02-01

    Very volatile organic compounds (VVOCs), as categorized by the WHO, are an important subgroup of indoor pollutants and cover a wide spectrum of chemical substances. Some VVOCs are components of products commonly used indoors, some result from chemical reactions and some are reactive precursors of secondary products. Nevertheless, there is still no clear and internationally accepted definition of VVOCs. Current approaches are based on the boiling point, and the saturation vapor pressure or refer to analytical procedures. A significant problem is that many airborne VVOCs cannot be routinely analyzed by the usually applied technique of sampling on Tenax TA® followed by thermal desorption GC/MS or by DNPH-sampling/HPLC/UV. Some VVOCs are therefore often neglected in indoor-related studies. However, VVOCs are of high significance for indoor air quality assessment and there is need for their broader consideration in measurement campaigns and material emission testing. © 2014 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  8. Indoor air radon dose assessment for elementary, middle and high schools at Ulju county in Korea

    International Nuclear Information System (INIS)

    Lee, Choong Wie; Kim, Hee Reyoung

    2016-01-01

    Ulsan is the largest industrial city and possesses the largest area among 7 metropolitan cities in Korea. Ulju county is one of the administrative districts of Ulsan, and covers over 70 % of Ulsan and is surrounded by mountain to the east and sea to the west, which has urban and rural area. Thus, there are many geological and industrial condition in its environment. Ministry of Environment (ME) of Korea is carrying out radon survey every 2 years, but this survey focuses on radon radioactivity of the houses and radon survey for schools isn't detailed. At schools, people with various age work and are educated for a specific time, therefore, it is needed to analyze the radon radioactivity concentration of indoor air to estimate the effect by the radon exposure. Indoor air radon radioactivity concentration and dose of 57 schools including elementary, middle and high schools in Ulju county were analyzed by using alpha track. It was understood that average radon concentrations of schools in Ulju county were being maintained below recommendation level although survey results of some schools showed 295 Bq/m 3 higher than regulation of Ministry of Environment for radon concentration, 148 Bq/m 3 . Indoor annual effective dose of 0.157 mSv by radon was found to be less than 7 % of the natural radiation exposure of 2.4 mSv when ICRP dose coefficient for adult male was applied. It was thought that further radon effect analysis for various ages including children was needed for more accurate dose assessment

  9. Indoor air radon dose assessment for elementary, middle and high schools at Ulju county in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choong Wie; Kim, Hee Reyoung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Ulsan is the largest industrial city and possesses the largest area among 7 metropolitan cities in Korea. Ulju county is one of the administrative districts of Ulsan, and covers over 70 % of Ulsan and is surrounded by mountain to the east and sea to the west, which has urban and rural area. Thus, there are many geological and industrial condition in its environment. Ministry of Environment (ME) of Korea is carrying out radon survey every 2 years, but this survey focuses on radon radioactivity of the houses and radon survey for schools isn't detailed. At schools, people with various age work and are educated for a specific time, therefore, it is needed to analyze the radon radioactivity concentration of indoor air to estimate the effect by the radon exposure. Indoor air radon radioactivity concentration and dose of 57 schools including elementary, middle and high schools in Ulju county were analyzed by using alpha track. It was understood that average radon concentrations of schools in Ulju county were being maintained below recommendation level although survey results of some schools showed 295 Bq/m{sup 3} higher than regulation of Ministry of Environment for radon concentration, 148 Bq/m{sup 3}. Indoor annual effective dose of 0.157 mSv by radon was found to be less than 7 % of the natural radiation exposure of 2.4 mSv when ICRP dose coefficient for adult male was applied. It was thought that further radon effect analysis for various ages including children was needed for more accurate dose assessment.

  10. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

    Science.gov (United States)

    Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E

    2010-02-01

    The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.

  11. Factors affecting the concentration of outdoor particles indoors: Existing data and data needs

    International Nuclear Information System (INIS)

    McKone, T.E.; Thatcher, T.L.; Fisk, W.J.; Sextro, R.G.; Sohn, M.D.; Delp, W.W.; Riley, W.J.

    2002-01-01

    Accurate characterization of particle concentrations indoors is critical to exposure assessments. It is estimated that indoor particle concentrations depend strongly on outdoor concentrations. For health scientists, knowledge of the factors that control the relationship of indoor particle concentrations to outdoor levels is particularly important. In this paper, we identify and evaluate sources of data for those factors that affect the transport to and concentration of outdoor particles indoors. To achieve this goal, we (i) identify and assemble relevant information on how particle behavior during air leakage, HVAC operation, and particle filtration effects indoor particle concentration; (ii) review and evaluate the assembled information to distinguish data that are directly relevant to specific estimates of particle transport from those that are only indirectly useful; and (iii) provide a synthesis of the currently available information on building air-leakage parameters and their effect on indoor particle matter concentrations

  12. Contribution of {sup 222}Rn-bearing water to indoor radon and indoor air quality assessment in hot spring hotels of Guangdong, China

    Energy Technology Data Exchange (ETDEWEB)

    Song Gang, E-mail: songg2005@126.co [School of Environmental Science and Engineering, Guangzhou University, Guangzhou 510006 (China); Wang Xinming [Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Chen Diyun; Chen Yongheng [School of Environmental Science and Engineering, Guangzhou University, Guangzhou 510006 (China)

    2011-04-15

    This study investigates the contribution of radon ({sup 222}Rn)-bearing water to indoor {sup 222}Rn in thermal baths. The {sup 222}Rn concentrations in air were monitored in the bathroom and the bedroom. Particulate matter (PM, both PM{sub 10} and PM{sub 2.5}) and carbon dioxide (CO{sub 2}) were also monitored with portable analyzers. The bathrooms were supplied with hot spring water containing 66-260 kBq m{sup -3} of {sup 222}Rn. The results show that the spray of hot spring water from the bath spouts is the dominant mechanism by which {sup 222}Rn is released into the air of the bathroom, and then it diffuses into the bedroom. Average {sup 222}Rn level was 110-410% higher in the bedrooms and 510-1200% higher in the bathrooms compared to the corresponding average levels when there was no use of hot spring water. The indoor {sup 222}Rn levels were influenced by the {sup 222}Rn concentrations in the hot spring water and the bathing times. The average {sup 222}Rn transfer coefficients from water to air were 6.2 x 10{sup -4}-4.1 x 10{sup -3}. The 24-h average levels of CO{sub 2} and PM{sub 10} in the hotel rooms were 89% and 22% higher than the present Indoor Air Quality (IAQ) standard of China. The main particle pollutant in the hotel rooms was PM{sub 2.5}. Radon and PM{sub 10} levels in some hotel rooms were at much higher concentrations than guideline levels, and thus the potential health risks to tourists and especially to the hotel workers should be of great concern, and measures should be taken to lower inhalation exposure to these air pollutants. - Highlights: {yields} {sup 222}Rn-bearing water is the main contributor to indoor radon in hot spring hotel. {yields} The PM{sub 2.5} and CO{sub 2} are also the main indoor pollutants in the hotel rooms. {yields} Higher radon and PM levels might have significant negative health effects to human. {yields} The radon transfer coefficients are consistent with the published data.

  13. Indoor air quality: The hidden side of the indoor environment

    NARCIS (Netherlands)

    Oliveira Fernandes, E. de; Bluyssen, P.M.; Clausen, G.H.

    1996-01-01

    The physical environment can be defined and understood in manv different ways, both from its nature, e.g., thermal, accoustic, etc., or its dimension, e.g., global, local, urban, indoors. The indoor environment is much more than the space or the light effects; it is the result of a complex

  14. Soil radium, soil gas radon and indoor radon empirical relationships to assist in post-closure impact assessment related to near-surface radioactive waste disposal.

    Science.gov (United States)

    Appleton, J D; Cave, M R; Miles, J C H; Sumerling, T J

    2011-03-01

    Least squares (LS), Theil's (TS) and weighted total least squares (WTLS) regression analysis methods are used to develop empirical relationships between radium in the ground, radon in soil and radon in dwellings to assist in the post-closure assessment of indoor radon related to near-surface radioactive waste disposal at the Low Level Waste Repository in England. The data sets used are (i) estimated ²²⁶Ra in the < 2 mm fraction of topsoils (eRa226) derived from equivalent uranium (eU) from airborne gamma spectrometry data, (ii) eRa226 derived from measurements of uranium in soil geochemical samples, (iii) soil gas radon and (iv) indoor radon data. For models comparing indoor radon and (i) eRa226 derived from airborne eU data and (ii) soil gas radon data, some of the geological groupings have significant slopes. For these groupings there is reasonable agreement in slope and intercept between the three regression analysis methods (LS, TS and WTLS). Relationships between radon in dwellings and radium in the ground or radon in soil differ depending on the characteristics of the underlying geological units, with more permeable units having steeper slopes and higher indoor radon concentrations for a given radium or soil gas radon concentration in the ground. The regression models comparing indoor radon with soil gas radon have intercepts close to 5 Bq m⁻³ whilst the intercepts for those comparing indoor radon with eRa226 from airborne eU vary from about 20 Bq m⁻³ for a moderately permeable geological unit to about 40 Bq m⁻³ for highly permeable limestone, implying unrealistically high contributions to indoor radon from sources other than the ground. An intercept value of 5 Bq m⁻³ is assumed as an appropriate mean value for the UK for sources of indoor radon other than radon from the ground, based on examination of UK data. Comparison with published data used to derive an average indoor radon: soil ²²⁶Ra ratio shows that whereas the published data are

  15. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR

    Science.gov (United States)

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...

  16. Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France.

    Science.gov (United States)

    Canha, N; Mandin, C; Ramalho, O; Wyart, G; Ribéron, J; Dassonville, C; Hänninen, O; Almeida, S M; Derbez, M

    2016-06-01

    The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Assessment of indoor air in Austrian apartments with and without visible mold growth

    Science.gov (United States)

    Haas, D.; Habib, J.; Galler, H.; Buzina, W.; Schlacher, R.; Marth, E.; Reinthaler, F. F.

    Fungal spores are transported across great distances in the outdoor air and are also regularly found indoors. Building conditions and behavior-related problems in apartments may lead to massive growth of mold within a very short period of time. The aim of this study was to evaluate whether the visible growth of mold indoors influences the concentration of fungal spores in the air as well as the variety of their species. Samples were collected from 66 households in Austria. For each sampling, the corresponding outdoor air was measured as reference value. The size of the visible mold growth was categorized in order to correlate the extent of mold growth with the concentration of airborne spores as well as the fungal genera. In order to determine fungal spore concentrations in the air, the one-stage MAS-100 ® air sampler was used. Malt extract agar (MEA) and dichloran glycerol agar (DG18) plates were used as culture media. The total colony forming units (CFU) per m 3 were determined. The fungi were identified from the isolated colonies. The results show that in apartments visibly affected by mold, the median values were significantly higher than those of apartments without visible mold growth. The extent of visible mold growth is significantly correlated with both concentration of fungal spores ( pPenicillium sp. and Aspergillus sp. ( pPenicillium and Aspergillus in the air of apartments is recommended for assessing fungal exposure.

  18. Radon in the indoor environment

    International Nuclear Information System (INIS)

    Vanmarcke, H.

    1998-01-01

    The objectives of R and D on radon in the indoor environment at SCK-CEN is to (1) to investigate the deposition of radon progeny in the human respiratory tract by means of direct measurements as a function of aerosol conditions; to assess the radon concentrations in buildings retrospectively with volume traps. Progress and main achievements in 1997 are reported on

  19. Indoor signal attenuation assessment via fuzzy logic

    Directory of Open Access Journals (Sweden)

    Alexandre de Assis Mota

    2011-09-01

    Full Text Available This work focuses on the analysis of signal´s attenuation in indoor environments using a fuzzy logic approach based on the Shadowing Signal Propagation Model (SSPM. The SSPM allows the characterization of the attenuation caused by the environment through the ? parameter present in this model. In addition to this, the Fuzzy Logic provides a form of approximate reasoning that allows the treatment of problems with incomplete, vague and imprecise information. Also, it offers a simple way to obtain a possible solution for a problem using the heuristic knowledge about a particular situation. The results show that the methodology produced satisfactory results, close to the ones yielded by experimental methods.

  20. Addiction to indoor tanning: relation to anxiety, depression, and substance use.

    Science.gov (United States)

    Mosher, Catherine E; Danoff-Burg, Sharon

    2010-04-01

    To assess the prevalence of addiction to indoor tanning among college students and its association with substance use and symptoms of anxiety and depression. Two written measures, the CAGE (Cut down, Annoyed, Guilty, Eye-opener) Questionnaire, used to screen for alcoholism, and the Diagnostic and Statistical Manual of Mental Disorders (Fourth Edition, Text Revision) (DSM-IV-TR) criteria for substance-related disorders, were modified to evaluate study participants for addiction to indoor tanning. Standardized self-report measures of anxiety, depression, and substance use also were administered. A large university (approximately 18 000 students) in the northeastern United States. A total of 421 college students were recruited from September through December 2006. Self-reported addiction to indoor tanning, substance use, and symptoms of anxiety and depression. Among 229 study participants who had used indoor tanning facilities, 90 (39.3%) met DSM-IV-TR criteria and 70 (30.6%) met CAGE criteria for addiction to indoor tanning. Students who met DSM-IV-TR and CAGE criteria for addiction to indoor tanning reported greater symptoms of anxiety and greater use of alcohol, marijuana, and other substances than those who did not meet these criteria. Depressive symptoms did not significantly vary by indoor tanning addiction status. Findings suggest that interventions to reduce skin cancer risk should address the addictive qualities of indoor tanning for a minority of individuals and the relationship of this behavior to other addictions and affective disturbance.

  1. Polluted air--outdoors and indoors.

    Science.gov (United States)

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  2. Indoor navigation by image recognition

    Science.gov (United States)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  3. Efficiency assessment of indoor environmental policy for air-conditioned offices in Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.

    2009-01-01

    To reduce carbon dioxide (CO 2 ) emissions through thermal energy conservation, air-conditioned offices in the subtropics are recommended to operate within specified ranges of indoor temperature, relative humidity and air velocity. As thermal discomfort leads to productivity loss, some indoor environmental policies for air-conditioned offices in Hong Kong are investigated in this study with relation to thermal energy consumption, CO 2 emissions from electricity use, and productivity loss due to thermal discomfort. Occupant thermal response is specifically considered as an adaptive factor in evaluating the energy consumption and productivity loss. The energy efficiency of an office is determined by the productivity which corresponds to the CO 2 generated. The results found that a policy with little impact on occupant thermal comfort and worker productivity would improve the office efficiency while the one with excessive energy consumption reduction would result in a substantial productivity loss. This study is a useful reference source for evaluating an indoor thermal environmental policy regarding the energy consumption, CO 2 emissions reduction, thermal comfort and productivity loss in air-conditioned offices in subtropical areas.

  4. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  5. Characterizing health impacts from indoor and outdoor exposure to fine particulates

    DEFF Research Database (Denmark)

    Vigon, Bruce; Fantke, Peter; McKone, Thomas E

    2016-01-01

    Exposure to fine particulate matter (PM2.5) pollution is a major contributor to human disease burden as continuously shown in the Global Burden of Disease study series. Exposures to PM2.5 concentration outdoors and indoors contribute almost equally to this burden. Despite the importance, health...... impacts from exposure to PM2.5 are often excluded from life cycle impact assessment (LCIA) characterization profiles. This is in large part because of the lack of well-vetted harmonized guidance about how to consistently assess the exposures and impacts of indoor and outdoor emissions of PM2.5 and its...... precursors. We present a framework for calculating characterization factors for indoor and outdoor emissions of primary PM2.5 and secondary PM2.5 precursors, and a roadmap for further refining this modelling framework for operational use in LCIA. The framework was developed over the last three years...

  6. Risky business: Behaviors associated with indoor tanning in US high school students.

    Science.gov (United States)

    Chapman, Stephanie; Ashack, Kurt; Bell, Eric; Sendelweck, Myra Ann; Dellavalle, Robert

    2017-09-15

    Understanding of associations between indoor tanning and risky health related behaviors such as sexual activity and substance abuse among high school students across the United States is incomplete. To identify risky health related behaviors among high school students utilizing indoor tanning and analyze differences between state specific data. Results from the Youth Risk Behavior Surveillance System (YRBSS) 2013 in 14 different states were analyzed. Participants were 90,414 high school students. Responses to questions assessing indoor tanning habits, sexual activity, and use of substances were analyzed. Sexual activity was associated with indoor tanning in 10 of 14 states, with Nebraska having the strongest association (adjusted odds ratio, 3.8; 95% CI, 2.4-6.2; p<0.001). Indoor tanning was also associated with use of alcohol, marijuana, ecstasy, cocaine, prescription medications, and cigarettes. Only 15 states asked students about their personal history of indoor tanning use, and Minnesota was excluded from our analysis as they administered a non-YRBS questionnaire. Additionally, our study only analyzed results from the 2013 YRBS. Lastly, our data was analyzed in 14 individual data sets, giving a high likelihood of Type 1 error. High school students utilizing indoor tanning are more likely to engage in sexual activity and substance abuse as compared to students who do not utilize indoor tanning.

  7. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances †

    Science.gov (United States)

    Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A.; Al-Khalifa, Hend S.

    2016-01-01

    In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space. PMID:27196906

  8. Spatial subdivision of complex indoor environments for 3D indoor navigation

    NARCIS (Netherlands)

    Diakite, A.A.; Zlatanova, S.

    2018-01-01

    As we realize that we spend most of our time in increasingly complex indoor environments, applications to assist indoor activities (e.g. guidance) have gained a lot of attention in the recent years. The advances in ubiquitous computing made possible the development of several spatial models

  9. Graph Model Based Indoor Tracking

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lu, Hua; Yang, Bin

    2009-01-01

    The tracking of the locations of moving objects in large indoor spaces is important, as it enables a range of applications related to, e.g., security and indoor navigation and guidance. This paper presents a graph model based approach to indoor tracking that offers a uniform data management...

  10. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study.

    Science.gov (United States)

    Sakellaris, Ioannis A; Saraga, Dikaia E; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G; Bluyssen, Philomena M

    2016-04-25

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  11. Numerical Analysis of Indoor Sound Quality Evaluation Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Yu-Tuan Chou

    2013-01-01

    Full Text Available Indoors sound field distribution is important to Room Acoustics, but the field suffers numerous problems, for example, multipath propagation and scattering owing to sound absorption by furniture and other aspects of décor. Generally, an ideal interior space must have a sound field with clear quality. This provides both the speaker and the listener with a pleasant conversational environment. This investigation uses the Finite Element Method to assess the acoustic distribution based on the indoor space and chamber volume. In this situation, a fixed sound source at different frequencies is used to simulate the acoustic characteristics of the indoor space. This method considers the furniture and decoration sound absorbing material and thus different sound absorption coefficients and configurations. The preliminary numerical simulation provides a method that can forecast the distribution of sound in an indoor room in complex situations. Consequently, it is possible to arrange interior furnishings and appliances to optimize acoustic distribution and environmental friendliness. Additionally, the analytical results can also be used to calculate the Reverberation Time and speech intelligibility for specified indoor space.

  12. Compliance with indoor tanning bans for minors among businesses in the USA.

    Science.gov (United States)

    Choy, Courtney C; Cartmel, Brenda; Clare, Rachel A; Ferrucci, Leah M

    2017-12-01

    Indoor tanning is a known risk factor for skin cancer and is especially dangerous for adolescents. Some states have passed indoor tanning bans for minors, but business compliance with the bans is not well understood. Thus far, studies have assessed ban compliance in one or two states at a time. This study aimed to assess compliance with indoor tanning bans for minors and knowledge of dangers and benefits of tanning among indoor tanning businesses. Female research assistants posing as minors telephoned a convenience sample of 412 businesses in 14 states with tanning bans for minors under age 17 or 18. We evaluated differences in compliance by census region and years since ban was implemented and differences in reported dangers and benefits by compliance. Most (80.1%) businesses told the "minor" caller she could not use the tanning facilities. Businesses in the south and in states with more recent bans were less compliant. Among those (n = 368) that completed the full interview, 52.2% identified burning and 20.1% mentioned skin cancer as potential dangers. However, 21.7% said dangers were no worse than the sun and 10.3% denied any dangers. Stated benefits included vitamin D (27.7%), social/cosmetic (27.2%), and treats skin diseases (26.4%), with only 4.9% reporting no benefits. While most businesses followed the indoor tanning ban when a minor called, one-fifth did not. Many stated inaccurate health claims. Additional enforcement or education might increase compliance with indoor tanning bans and action is needed to prevent businesses from stating false health information.

  13. [Health evaluation of trichloroethylene in indoor air : communication from the German ad-hoc working group on indoor guidelines of the Indoor Air Hygiene Committee and of the states' supreme health authorities].

    Science.gov (United States)

    2015-07-01

    In the European Hazardous Substances Regulation No 1272/2008 trichloroethylene has been classified as a probable human carcinogen and a suspected mutagen. According to several Committees (German Committee on Hazardous Substances, European Scientific Committee on Occupational Exposure Limits, European Chemicals Agency´s Committee for Risk Assessment (ECHA-RAC)) concentrations of trichloroethylene cytotoxic to renal tubuli may increase the risk to develop renal cancer. At non-cytotoxic concentrations of trichloroethylene a much lower cancer risk may be assumed. Therefore, evaluating the cancer risk to the public following inhalation of trichloroethylene ECHA-RAC has assumed a sublinear exposure-response relationship for carcinogenicity of trichloroethylene. Specifically, ECHA-RAC assessed a cancer risk of 6.4 × 10(- 5) (mg/m(3))(- 1) following life time exposure to trichloroethylene below a NOAEC for renal cytotoxicity of 6 mg trichloroethylene/m(3). Further evaluation yields a life-time risk of 10(- 6) corresponding to 0.02 mg trichloroethylene/m(3). This concentration is well above the reference (e.g. background) concentration of trichloroethylene in indoor air. Consequently the Ad-hoc Working Group on Indoor Guidelines recommends 0.02 mg trichloroethylene/m(3) as a risk-related guideline for indoor air. Measures to reduce exposure are considered inappropriate at concentrations below this guideline.

  14. Moisture Buffer Effect and its Impact on Indoor Environment

    DEFF Research Database (Denmark)

    Zhang, Mingjie; Qin, Menghao; Chen, Zhi

    2017-01-01

    The moisture buffer effect of building materials may have great influence on indoor hygrothermal environment. In order to characterize the moisture buffering ability of materials, the basic concept of moisture buffer value (MBV) is adopted. Firstly, a theoretical correction factor is introduced...... in this paper. The moisture uptake/release by hygroscopic materials can be calculated with the factor and the basic MBV. Furthermore, the validation of the correction factor is carried out. The impact of moisture buffering on indoor environment is assessed by using numerical simulations. The results show...

  15. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso [Goce Delcev University, Faculty of Medical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Boev, Blazo [Goce Delcev University, Faculty of Natural and Technical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Zunic, Zora S. [University of Belgrade, Institute of Nuclear Sciences ' ' Vinca' ' , Belgrade (Serbia); Ivanova, Kremena; Tsenova, Martina [National Center of Radiobiology and Radiation Protection, Sofia (Bulgaria); Ristova, Mimoza [University in Ss. Cyril and Methodius, Faculty of Natural Sciences and Mathematic, Institute of Physics, Skopje (Macedonia, The Former Yugoslav Republic of); Ajka, Sorsa [Croatian Geological Survey, Zagreb (Croatia); Bossew, Peter [German Federal Office for Radiation Protection, Berlin (Germany)

    2016-05-15

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m{sup 3} for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  16. Indoor microclimate in a South African school: impact of indoor environmental factors

    CSIR Research Space (South Africa)

    Essah, EA

    2016-07-01

    Full Text Available Demand for good indoor air quality is increasing as people recorgnise the risks to their health and productivity from indoor pollutants. There is a tendency to reduce ventilation rates to ensure energy conservation in buildings; in this instance...

  17. Effectiveness of Indoor Plant to Reduce CO2 in Indoor Environment

    Directory of Open Access Journals (Sweden)

    Suhaimi Mohd Mahathir

    2017-01-01

    Full Text Available Modern country strongly emphasizes on indoor air quality (IAQ because it can effect on human health and productivity. Numerous efforts were performed to make sure that sustainability of IAQ is guaranteed. In the last 4th decade, researchers discover that indoor plants have abilities to reduce indoor air pollution. Generally, plants, carbon dioxide (CO2, light, and temperature involve in the photosynthesis process. This paper intends to study the effectiveness of seven indoor plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium to reduce CO2 with different light level. This study was conducted in one cubic meter of chamber, and each plant was put into the chamber individually with CO2 concentration in the chamber is set at 1000±50ppm, and light intensities is set at 300 and 700 lux, while temperature were fixed at 25±1°C. Based on the results, only the Spider Plant was not able to absorb CO2 during the test at 300 lux of light intensity. Meanwhile, Prayer Plant performed well when tested at 300 or 700 lux of light intensity compare to other investigates plants. This study can conclude that light intensity play an important role for the plant to absorb CO2 effectively. All the indoor plants absorbed more CO2, when the light intensity is increased.

  18. Indoor thoron studies along the northeast coast of Andhra Pradesh, India

    International Nuclear Information System (INIS)

    Vinay Kumar Reddy, K.; Sudarshan, A.; Gopal Reddy, Ch.; Yadagiri Reddy, P.; Rama Reddy, K.

    2013-01-01

    The beach sands of the northeast coast of Andhra Pradesh are well known for heavy metal mineralization. The process of extraction of the metals can enhance the natural background radiation levels and hence it is essential to establish the radiological base-line data to take necessary remedial action to preserve and protect the coastal environment. The assessment of indoor radioactivity levels has been carried out by choosing 13 villages long the northeast coast of Andhra Pradesh covering around 150 km from Vishakapattanam to Kalingapattanam. The present paper discusses the indoor thoron levels in the areas along the northeast coast of Andhra Pradesh. The SSNTD based twin chamber dosimeters were employed for the assessment of the concentration of thoron and its progeny levels. The average indoor thoron concentrations in this area are found to be 44.1 ± 28.2 Bq.m -3 . The inhalation dose due to thoron has been evaluated using equilibrium factors and discussed in detail. (author)

  19. Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows.

    Science.gov (United States)

    Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Röösli, Martin; Brink, Mark; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc

    2018-01-18

    Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.

  20. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  1. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  2. Comparison of sampling methods for the assessment of indoor microbial exposure

    DEFF Research Database (Denmark)

    Frankel, M; Timm, Michael; Hansen, E W

    2012-01-01

    revealed. This study thus facilitates comparison between methods and may therefore be used as a frame of reference when studying the literature or when conducting further studies on indoor microbial exposure. Results also imply that the relatively simple EDC method for the collection of settled dust may...

  3. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  4. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  5. Assessment and determinants of airborne bacterial and fungal concentrations in different indoor environments: Homes, child day-care centres, primary schools and elderly care centres

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João Cavaleiro; Pereira, Cristiana; Teixeira, João Paulo; de Oliveira Fernandes, Eduardo

    2015-05-01

    Until now the influence of risk factors resulting from exposure to biological agents in indoor air has been far less studied than outdoor pollution; therefore the uncertainty of health risks, and how to effectively prevent these, remains. This study aimed (i) to quantify airborne cultivable bacterial and fungal concentrations in four different types of indoor environment as well as to identify the recovered fungi; (ii) to assess the impact of outdoor bacterial and fungal concentrations on indoor air; (iii) to investigate the influence of carbon dioxide (CO2), temperature and relative humidity on bacterial and fungal concentrations; and (iv) to estimate bacterial and fungal dose rate for children (3-5 years old and 8-10 years old) in comparison with the elderly. Air samples were collected in 68 homes, 9 child day-care centres, 20 primary schools and 22 elderly care centres, in a total of 264 rooms with a microbiological air sampler and using tryptic soy agar and malt extract agar culture media for bacteria and fungi growth, respectively. For each building, one outdoor representative location were identified and simultaneously studied. The results showed that child day-care centres were the indoor microenvironment with the highest median bacterial and fungal concentrations (3870 CFU/m3 and 415 CFU/m3, respectively), whereas the lowest median concentrations were observed in elderly care centres (222 CFU/m3 and 180 CFU/m3, respectively). Indoor bacterial concentrations were significantly higher than outdoor concentrations (p < 0.05); whereas the indoor/outdoor ratios for the obtained fungal concentrations were approximately around the unit. Indoor CO2 levels were associated with the bacterial concentration, probably due to occupancy and insufficient ventilation. Penicillium and Cladosporium were the most frequently occurring fungi. Children's had two times higher dose rate to biological pollutants when compared to adult individuals. Thus, due to children

  6. Measurement and health risk assessment of PM2.5, flame retardants, carbonyls and black carbon in indoor and outdoor air in kindergartens in Hong Kong.

    Science.gov (United States)

    Deng, Wen-Jing; Zheng, Hai-Long; Tsui, Anita K Y; Chen, Xun-Wen

    2016-11-01

    Indoor air pollution is closely related to children's health. Polybrominated diphenyl ethers (PBDEs) and dechlorane plus (DP) transmitted through indoor PM 2.5 and dust, along with carbonyl compounds and black carbon (BC) aerosol were analysed in five Hong Kong kindergartens. The results showed that 60% of the median PM 2.5 levels (1.3×10 1 to 2.9×10 1 μg/m 3 for indoor; 9.5 to 8.8×10 1 μg/m 3 for outdoor) in the five kindergartens were higher than the guidelines set by the World Health Organization (2.5×10 1 μg/m 3 ). Indoor PM 2.5 mass concentrations were correlated with outdoor PM 2.5 in four of the kindergartens. The PBDEs (0.10-0.64ng/m 3 in PM 2.5 ; 0.30-2.0×10 2 ng/g in dust) and DP (0.05-0.10ng/m 3 in PM 2.5 ; 1.3-8.7ng/g in dust) were detected in 100% of the PM 2.5 and dust samples. Fire retardant levels in the air were not correlated with the levels of dust in this study. The median BC concentrations varied by >7-fold from 8.8×10 2 ng/m -3 to 6.7×10 3 ng/m -3 and cooking events might have caused BC concentrations to rise both indoors and outdoors. The total concentrations of 16 carbonyls ranged from 4.7×10 1 μg/m 3 to 9.3×10 1 μg/m 3 indoors and from 1.9×10 1 μg/m 3 to 4.3×10 1 μg/m 3 outdoors, whilst formaldehyde was the most abundant air carbonyl. Indoor carbonyl concentrations were correlated with outdoor carbonyls in three kindergartens. The health risk assessment showed that hazard indexes (HIs) HIs of non-cancer risks from PBDEs and DPs were all lower than 0.08, whilst non-cancer HIs of carbonyl compounds ranged from 0.77 to 1.85 indoors and from 0.50 to 0.97 outdoors. The human intake of PBDEs and DP through inhalation of PM 2.5 accounted for 78% to 92% of the total intake. The cancer hazard quotients (HQs) of formaldehyde ranged from 4.5E-05 to 2.1E-04 indoors and from 1.9E-05 to 6.2E-05 outdoors. In general, the indoor air pollution in the five Hong Kong kindergartens might present adverse effects to children, although different

  7. Assessment of Effective Dose Equivalent of Indoor 222Rn Daughters in Inchass

    International Nuclear Information System (INIS)

    Ali, E.M.; Taha, T.M.; Gomaa, M.A.; El-Hussein, A.M.; Ahmad, A.A.

    2000-01-01

    The dominant component of natural radiation dose for the general population comes from the radon gas 222 Rn and its short-lived decay products, Ra A ( 214 Po), Ra B ( 214 Pb), Ra C ( 214 Bi), Ra C( 214 Po) in the breathing air. The objective of the present work is to assess the affective dose equivalent of the inhalation exposure of indoor 222 Rn for occupational workers. Average indon concentrations (Bqm -3 ) were monitored in several departments in Nuclear Research Center by radon monitor. We have calculated the lung dose equivalent and the effective dose equivalent for the Egyptian workers due to inhalation exposure of an equilibrium equivalent concentrations of radon daughters which varies from 0.27 to 2.5 mSvy -1 and 0.016 to 0.152mSvy -1 respectively. The annual effective doses obtained are within the accepted range of ICRP recommendations

  8. Slovak Republic, indoor measurements

    International Nuclear Information System (INIS)

    Vicanova, M.; Daniel, S.

    2006-01-01

    In this report the annual average effective doses from indoor radon exposure were calculated for each district of Slovakia. The population-weighted arithmetic mean of indoor radon concentration was calculated for every district considering different types of houses.

  9. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Directory of Open Access Journals (Sweden)

    Ioannis A. Sakellaris

    2016-04-01

    Full Text Available Indoor environmental conditions (thermal, noise, light, and indoor air quality may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain. Occupants assessed indoor environmental quality (IEQ using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality, and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index, and building characteristics (office type and building’s location. Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  10. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Science.gov (United States)

    Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608

  11. Indoor air quality – buildings design

    Directory of Open Access Journals (Sweden)

    Juhásová Šenitková Ingrid

    2017-01-01

    Full Text Available Growing attention is being paid to indoor air quality as one of the main health and well-being factors. The indoor research is concerned mostly to indoor air chemicals within indoor engineering related to building design. The providing good indoor air quality can be achieved effectively by avoiding or reducing indoor air pollution sources and by selecting low-polluting building materials, both being low-cost and energyefficient solutions. On the base of the last large experimental monitoring results, it was possible to know the level of selected indoor chemicals occurrence, rank them as well as to predict the tendencies of occurrence and establish the priorities for the future. There has been very limited attention to rigorous analysis of buildings actual environmental impacts to date. Healthy/green/sustainable building practices are typically applied in unsystematic and inconsistent ways often without resolution of inherent conflicts between and among such practices. Designers, products manufacturers, constructors, and owners declare their buildings and the applied technologies to be beneficial to the environment without validating those claims.

  12. State Indoor Tanning Laws and Prevalence of Indoor Tanning Among US High School Students, 2009-2015.

    Science.gov (United States)

    Qin, Jin; Holman, Dawn M; Jones, Sherry Everett; Berkowitz, Zahava; Guy, Gery P

    2018-07-01

    To examine the association between state indoor tanning laws and indoor tanning behavior using nationally representative samples of US high school students younger than 18 years. We combined data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Surveys (n = 41 313) to analyze the association between 2 types of state indoor tanning laws (age restriction and parental permission) and the prevalence of indoor tanning during the 12 months before the survey, adjusting for age, race/ethnicity, and survey year, and stratified by gender. Age restriction laws were associated with a 47% (P tanning prevalence among female high school students. Parental permission laws were not found to be associated with indoor tanning prevalence among either female or male high school students. Age restriction laws could contribute to less indoor tanning, particularly among female high school students. Such reductions may reduce the health and economic burden of skin cancer.

  13. Workshop on indoor air quality research needs

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

  14. Workshop on indoor air quality research needs

    International Nuclear Information System (INIS)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized

  15. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  16. Accurate estimation of indoor travel times

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Stisen, Allan

    2014-01-01

    The ability to accurately estimate indoor travel times is crucial for enabling improvements within application areas such as indoor navigation, logistics for mobile workers, and facility management. In this paper, we study the challenges inherent in indoor travel time estimation, and we propose...... the InTraTime method for accurately estimating indoor travel times via mining of historical and real-time indoor position traces. The method learns during operation both travel routes, travel times and their respective likelihood---both for routes traveled as well as for sub-routes thereof. InTraTime...... allows to specify temporal and other query parameters, such as time-of-day, day-of-week or the identity of the traveling individual. As input the method is designed to take generic position traces and is thus interoperable with a variety of indoor positioning systems. The method's advantages include...

  17. Indoor ionizing radiation

    International Nuclear Information System (INIS)

    Ericson, S.O.; Lindvall, T.; Maansson, L-G.

    1986-01-01

    Radiation in indoor air is discussed in the perspective of the effective dose equivalents from other sources of radiation. Estimates of effective doses equivalents from indoor radon and its contribution to lung cancer incidence are reviewed. Swedish experiences with cost effective remedial actions are presented. The authors present optimal strategies for screening measurements and remedial actions in cost-benefit perspective. (author.)

  18. Indoor air quality in Brazilian universities.

    Science.gov (United States)

    Jurado, Sonia R; Bankoff, Antônia D P; Sanchez, Andrea

    2014-07-11

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  19. Comparison of background levels of culturable fungal spore concentrations in indoor and outdoor air in southeastern Austria

    Science.gov (United States)

    Haas, D.; Habib, J.; Luxner, J.; Galler, H.; Zarfel, G.; Schlacher, R.; Friedl, H.; Reinthaler, F. F.

    2014-12-01

    Background concentrations of airborne fungi are indispensable criteria for an assessment of fungal concentrations indoors and in the ambient air. The goal of this study was to define the natural background values of culturable fungal spore concentrations as reference values for the assessment of moldy buildings. The concentrations of culturable fungi were determined outdoors as well as indoors in 185 dwellings without visible mold, obvious moisture problems or musty odor. Samples were collected using the MAS-100® microbiological air sampler. The study shows a characteristic seasonal influence on the background levels of Cladosporium, Penicillium and Aspergillus. Cladosporium sp. had a strong outdoor presence, whereas Aspergillus sp. and Penicillium sp. were typical indoor fungi. For the region of Styria, the median outdoor concentrations are between 100 and 940 cfu/m³ for culturable xerophilic fungi in the course of the year. Indoors, median background levels are between 180 and 420 cfu/m³ for xerophilic fungi. The I/O ratios of the airborne fungal spore concentrations were between 0.2 and 2.0. For the assessment of indoor and outdoor air samples the dominant genera Cladosporium, Penicillium and Aspergillus should receive special consideration.

  20. Uptake of chemicals from indoor air: Pathways and health effects

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2016-01-01

    Building occupants are exposed to manufactured chemicals. Exposure in the indoor environment can occur via non-dietary ingestion (e.g. indoor dust), inhalation and dermal absorption including dermal uptake directly from air. The extent of dermal uptake from air has been previously studied...... for volatile organic compounds (VOC). Not much is however known about its role for semivolatile organics (SVOC) and therefore this exposure pathway is often neglected in exposure assessments. Dermal uptake received attention with regards to contact transfer from contaminated surfaces. Recent modeling efforts...... intake from inhalation. Further experiments have been conducted with nicotine and the results are similar. Some of the SVOCs present indoors may have adverse health effects or are categorized as potential endocrine-disrupting compounds. It has been suggested that the health effects of a chemical may...

  1. Investigations on indoor radon in Austria, Part 1: Seasonality of indoor radon concentration

    International Nuclear Information System (INIS)

    Bossew, Peter; Lettner, Herbert

    2007-01-01

    In general, indoor radon concentration is subject to seasonal variability. The reasons are to be found (1) in meteorological influence on the transport properties of soil, e.g. through temperature, frozen soil layers and soil water saturation; and (2) in living habits, e.g. the tendency to open windows in summer and keep them closed in winter, which in general leads to higher accumulation of geogenic Rn in closed rooms in winter. If one wants to standardize indoor Rn measurements originally performed at different times of the year, e.g. in order to make them comparable, some correction transform as a function of measurement time which accounts for these effects must be estimated. In this paper, the seasonality of indoor Rn concentration measured in Austria is investigated as a function of other factors that influence indoor Rn. Indoor radon concentration is clearly shown to have seasonal variability, with higher Rn levels in winter. However, it is complicated to quantify the effect because, as a consequence of the history of an Rn survey, the measurement season maybe correlated to geological regions, which may introduce a bias in the estimate of the seasonality amplitude

  2. Internet-Based Indoor Navigation Services

    OpenAIRE

    Zeinalipour-Yazti, Demetrios; Laoudias, Christos; Georgiou, Kyriakos

    2017-01-01

    Smartphone advances are leading to a class of Internet-based Indoor Navigation services. IIN services rely on geolocation databases that store indoor models, comprising floor maps and points of interest, along with wireless, light, and magnetic signals for localizing users. Developing IIN services creates new information management challenges - such as crowdsourcing indoor models, acquiring and fusing big data velocity signals, localization algorithms, and custodians' location privacy. Here, ...

  3. Assessment of tobacco heating product THP1.0. Part 4: Characterisation of indoor air quality and odour.

    Science.gov (United States)

    Forster, Mark; McAughey, John; Prasad, Krishna; Mavropoulou, Eleni; Proctor, Christopher

    2018-03-01

    The tobacco heating product THP1.0, which heats but does not burn tobacco, was tested as part of a modified-risk tobacco product assessment framework for its impacts on indoor air quality and residual tobacco smoke odour. THP1.0 heats the tobacco to less than 240 °C ± 5 °C during puffs. An environmentally controlled room was used to simulate ventilation conditions corresponding to residential, office and hospitality environments. An analysis of known tobacco smoke constituents, included CO, CO 2 , NO, NO 2 , nicotine, glycerol, 3-ethenyl pyridine, sixteen polycyclic aromatic hydrocarbons, eight volatile organic compounds, four carbonyls, four tobacco-specific nitrosamines and total aerosol particulate matter. Significant emissions reductions in comparison to conventional cigarettes were measured for THP1.0. Levels of nicotine, acetaldehyde, formaldehyde and particulate matter emitted from THP1.0 exceeded ambient air measurements, but were more than 90% reduced relative to cigarette smoke emissions within the laboratory conditions defined Residual tobacco smoke odour was assessed by trained sensory panels after exposure of cloth, hair and skin to both mainstream and environmental emissions from the test products. Residual tobacco smoke odour was significantly lower from THP1.0 than from a conventional cigarette. These data show that using THP1.0 has the potential to result in considerably reduced environmental emissions that affect indoor air quality relative to conventional cigarettes. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows

    Science.gov (United States)

    Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc

    2018-01-01

    Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios—of open, tilted, and closed windows—were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor–indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor–indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows. PMID:29346318

  5. Estimation of the variations of ventilation rate and indoor radon concentration using the observed wind velocity and indoor-outdoor temperature difference

    International Nuclear Information System (INIS)

    Nagano, Katsuhiro; Inose, Yuichi; Kojima, Hiroshi

    2006-01-01

    The indoor radon concentration in the building depends on the ventilation rate. Measurement results of indoor-outdoor pressure difference showed the ventilation rate correlated closely with the indoor-outdoor pressure difference. The observation results showed that one of factor of indoor-outdoor pressure difference was the wind velocity. When the wind velocity is small, the ventilation rate is affected by the indoor-outdoor temperature difference and the effect depends on the wind velocity. The temporal variation of indoor radon concentration was predicted by the time depending indoor radon balance model and the ventilation rate estimated from the wind velocity and the indoor-outdoor temperature difference. The temporal variations of predicted radon concentration gave good agreement with the experimental values. The measurement method, indoor radon concentration and ventilation rate, factors of temporal variation of ventilation rate, and prediction of indoor radon concentration are reported. (S.Y.)

  6. The Isprs Benchmark on Indoor Modelling

    Science.gov (United States)

    Khoshelham, K.; Díaz Vilariño, L.; Peter, M.; Kang, Z.; Acharya, D.

    2017-09-01

    Automated generation of 3D indoor models from point cloud data has been a topic of intensive research in recent years. While results on various datasets have been reported in literature, a comparison of the performance of different methods has not been possible due to the lack of benchmark datasets and a common evaluation framework. The ISPRS benchmark on indoor modelling aims to address this issue by providing a public benchmark dataset and an evaluation framework for performance comparison of indoor modelling methods. In this paper, we present the benchmark dataset comprising several point clouds of indoor environments captured by different sensors. We also discuss the evaluation and comparison of indoor modelling methods based on manually created reference models and appropriate quality evaluation criteria. The benchmark dataset is available for download at: html"target="_blank">http://www2.isprs.org/commissions/comm4/wg5/benchmark-on-indoor-modelling.html.

  7. Assessments of activated carbon prepared from date stones in adsorption of indoor radon

    International Nuclear Information System (INIS)

    Abudaia, J.I.; Al-Ezzaby, Suliman M.; Dawad, E.; Alawar, A.; Al-Shreide, A.

    2015-01-01

    Radiochemical department (RCD) at Tajoura Nuclear Research Center (TNRC) in Tripoli city is one of the fewest workplaces which have experienced indoor level evaluation. In this present study, it is intended to investigate the efficiency of domestic activated carbons (AC) derived from most locally available agricultural by products date stones (DS) in the adsorption of indoor radon-222 (' 222 Rn) at different oriented sites of RCD. The average indoor radon concentration values in the study areas varied from (34±3.0) Bq/m 3 to (192.7±9.1) Bq/m 3 , while the values of the annual effective dose varied from (0.355) mSv/y to (0.974) mSv/y. All obtained values were within the recommended action levels of (200 - 300) Bq/m 3 and 2.4 mSv/y which are given by International Commission on Radiological Protection (ICRP) in 1993 and 1987 respectively. A designed set up of portable ACDS canisters are proposed to be utilized in other different workplaces such as schools, where educational buildings are considered as locations of ventilation deficiency and high occupancy times for children and such naturally occurring radio-active radon is distinguished as a second leading cause of lung cancer worldwide.(author)

  8. Indoor radon in houses built on gravel and sand deposits in southern Finland

    Directory of Open Access Journals (Sweden)

    Hutri, K.-L.

    1993-06-01

    Full Text Available Studies by the Finnish Centre for Radiation and Nuclear Safety (STUK have shown that, in Finland, indoor radon concentrations are almost twice as high in houses built on sand or gravel as in houses built on other soil types. The aim of this study was to assess the radon risk on eskers, ice-marginal formations, and other gravel and sand deposits on the basis of factors that can be determined from geological maps. Altogether, 514 houses built on gravel and sand deposits were selected for the study from the indoor radon database of STUK. Several geological parameters were determined. Empirical statistical models were used to assess the significance of factors affecting indoor radon in glaciofluvial deposits and the sand-dominant littoral deposits occurring in association with them. A relationship was found between increased indoor radon concentrations and the location of a house on a steep-sided esker, in the southeastern rapakivi granite area and on the upper slope or top of an esker. The steepness of the slope also increased the radon concentration in houses on steep-sided eskers. The effect of the topographic features is due to subterranean air-flows. As estimated from the very sparse till sampling, the elevated uranium concentration increased the indoor radon concentration only in houses built on littoral deposits around eskers and ice-marginal formations.

  9. Controlling Indoor Air Pollution from Moxibustion

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2016-06-01

    Full Text Available Indoor air quality (IAQ control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs of traditional Chinese medicine (TCM may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2, carbon monoxide (CO, formaldehyde (HCHO, total volatile organic compounds (TVOCs, airborne particulate matter with a diameter of ≤10 µm (PM10 and ≤2.5 µm (PM2.5 during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  10. Multi-dimensional indoor location information model

    NARCIS (Netherlands)

    Xiong, Q.; Zhu, Q.; Zlatanova, S.; Huang, L.; Zhou, Y.; Du, Z.

    2013-01-01

    Aiming at the increasing requirements of seamless indoor and outdoor navigation and location service, a Chinese standard of Multidimensional Indoor Location Information Model is being developed, which defines ontology of indoor location. The model is complementary to 3D concepts like CityGML and

  11. Psychotropic substances in indoor environments.

    Science.gov (United States)

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Growth of indoor fungi on gypsum.

    Science.gov (United States)

    Segers, F J J; van Laarhoven, K A; Wösten, H A B; Dijksterhuis, J

    2017-08-01

    To have a better understanding of fungal growth on gypsum building materials to prevent indoor fungal growth. Gypsum is acquired by mining or as a by-product of flue-gas desulphurization or treatment of phosphate ore for the production of fertilizer. Natural gypsum, flue-gas gypsum and phosphogypsum therefore have different mineral compositions. Here, growth of fungi on these types of gypsum was assessed. Conidia of the indoor fungi Aspergillus niger, Cladosporium halotolerans and Penicillium rubens were inoculated and observed using microscopic techniques including low-temperature scanning electron microscopy. Elemental analysis of gypsum was done using inductively coupled plasma atomic emission spectroscopy and segmented flow analysis. Moisture content of the gypsum was determined using a dynamic vapour sorption apparatus. Aspergillus niger, C. halotolerans and P. rubens hardly germinated on natural gypsum and flue-gas gypsum. The latter two fungi did show germination, outgrowth, and conidiation on phosphogypsum, while A. niger hardly germinated on this substrate. Other experiments show that C. halotolerans and P. rubens can develop in pure water, but A. niger does not. The observations show that the lack of germination of three indoor fungi is explained by the low amount of phosphor in natural, flue-gas and laboratory-grade gypsum. Additionally, C. halotolerans and P. rubens can develop in pure water, while conidia of A. niger do not show any germination, which is explained by the need for organic molecules of this species to induce germination. Indoor fungal growth is a potential threat to human health and causes damage to building materials. This study possibly helps in the application of the right type of gypsum in buildings. © 2017 The Society for Applied Microbiology.

  13. NFC Internal: An Indoor Navigation System

    Science.gov (United States)

    Ozdenizci, Busra; Coskun, Vedat; Ok, Kerem

    2015-01-01

    Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC)-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability. PMID:25825976

  14. Introduction to Indoor Air Quality

    Science.gov (United States)

    ... Offices Regional Offices Labs and Research Centers Indoor Air Quality (IAQ) Contact Us Share Introduction to Indoor Air Quality Health Effects Primary Causes Identifying Problems Improving IAQ ...

  15. Indoor Air Quality in Schools

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  16. 9 CFR 3.102 - Facilities, indoor.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Facilities, indoor. 3.102 Section 3... Marine Mammals Facilities and Operating Standards § 3.102 Facilities, indoor. (a) Ambient temperature. The air and water temperatures in indoor facilities shall be sufficiently regulated by heating or...

  17. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  18. Indoor Multi-Dimensional Location GML and Its Application for Ubiquitous Indoor Location Services

    NARCIS (Netherlands)

    Zhu, Qing; Li, Yun; Xiong, Qing; Zlatanova, S.; Ding, Yulin; Zhang, Yeting; Zhou, Yan

    2016-01-01

    The Open Geospatial Consortium (OGC) Geography Markup Language (GML) standard provides basic types and a framework for defining geo-informational data models such as CityGML and IndoorGML, which provide standard information models for 3D city modelling and lightweight indoor network navigation.

  19. Capturing Hotspots For Constrained Indoor Movement

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2013-01-01

    Finding the hotspots in large indoor spaces is very important for getting overloaded locations, security, crowd management, indoor navigation and guidance. The tracking data coming from indoor tracking are huge in volume and not readily available for finding hotspots. This paper presents a graph......-based model for constrained indoor movement that can map the tracking records into mapping records which represent the entry and exit times of an object in a particular location. Then it discusses the hotspots extraction technique from the mapping records....

  20. Environmental assessment of indoor radon gas exposure health hazards and some of its public risks

    International Nuclear Information System (INIS)

    Hussein, Abd El-Razik. Z.; Ibrahim, M.Se.; Ragab, M.H.; El-Bukhari, M.S.

    2005-01-01

    This study examine the relationship between indoor radon gas exposure and the cancer risk and housing characteristics in lung cancer risk houses (CRH) compared to non lung cancer risk houses (NCRH). Mean radon concentrations measured by active method were significantly higher among CRH compared to NCRH, 9:93 pCi/L versus 4.56 pCi/L, respectively. There was no statistically significant diurnal variation as regards radon levels in all examined houses. Indoor radon concentrations show statistically significance in houses with bad ventilation (low air change rate) compared to houses with good ventilation (high air change rate). Houses with floor material of tiles, had statistically significant higher radon concentrations. Neither finishing wall material nor indoor gas source shows statistically significance as regard radon levels. Radon levels > 4 pCi/L (US EPA action level) were statistically significance higher in bed rooms compared levels in living rooms. High radon concentrations were reported in lung cane risk houses and in houses with bad ventilation

  1. Integrated indoor and outdoor exposure assessment framework for fine particulate matter pollution

    DEFF Research Database (Denmark)

    McKone, Thomas E; Hodas, Natasha; Apte, Joshua S.

    2016-01-01

    The 2010 Global Burden of Disease report demonstrates that fine particulate matter (PM2.5) pollution is the major environmental contributor to mortality. Exposures outdoors (ambient) and indoors (household) contribute almost qually to this burden. Unfortunately, the health impacts from exposure t...

  2. Office Building Occupant's Guide to Indoor Air Quality

    Science.gov (United States)

    ... about physical aspects of the workplace: location, work environment, availability of natural light and the aesthetics of office design, such ... people can do to ensure that their indoor environment is a healthy one. IAQ Building Education and Assessment Model (I-BEAM) : EPA's I-BEAM software program ...

  3. Effects of radon in indoor air studied

    International Nuclear Information System (INIS)

    Auvinen, A.

    1994-01-01

    Radon is an odorless, tasteless and colourless radioactive noble gas that enters indoor air from the ground. Radon causes lung cancer. A committee set up to evaluate the health risks of chemical substances has been drafting a report on radon, which will compile the major research findings on the lung cancer risk posed by radon. Animal tests have shown that even small doses of radon can cause lung cancer. Smokers seem to contract radon-induced lung cancer more readily than non-smokers. Because research findings have been conflicting, however, it is not known exactly how high the risk of lung cancer caused by indoor radon exposure really is. Several major research projects are under way to obtain increasingly accurate risk assessments. An on-going European joint project brings together several studies - some already finished, some still being worked on. In this way it will be possible to get more accurate risk assessments than from individual studies. In order to prevent lung cancer, it is important to continue the work of determining and reducing radon connects and to combat smoking. (orig.)

  4. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  5. Managing Indoor Air Quality in Schools.

    Science.gov (United States)

    Woolums, Jennifer

    This publication examines the causes and effects of poor indoor air quality and provides information for reducing exposure to indoor contaminants in schools. It discusses the various indoor pollutants found in schools, including dust, chemical agents, gases, and volatile organic compounds; where they are found in schools; and their health effects…

  6. Indoor climate design for a monumental building with periodic high indoor moisture loads

    NARCIS (Netherlands)

    Schijndel, van A.W.M.; Lony, R.J.M.; Schellen, H.L.

    2008-01-01

    The paper presents a case study on the performance based design for the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated and evaluated. The results include the influence of hygric inertia

  7. Indoor air quality: a UK perspective

    International Nuclear Information System (INIS)

    Wadge, A.

    1995-01-01

    Outdoor air quality has generally improved in the UK over the last 2 decades but during this period changing conditions within the home have tended to reduce ventilation and increase the opportunity for accumulation of undesirable levels of indoor air pollutants. Information obtained from laboratory and epidemiological studies suggest that indoor air pollutants are an important cause of avoidable morbidity and mortality in the UK. This paper reviews the major indoor air pollutants of concern in the UK and considers some of the special issues relevant to indoor environment. (author) 3 figs., 37 refs

  8. Indoor localization using magnetic fields

    Science.gov (United States)

    Pathapati Subbu, Kalyan Sasidhar

    Indoor localization consists of locating oneself inside new buildings. GPS does not work indoors due to multipath reflection and signal blockage. WiFi based systems assume ubiquitous availability and infrastructure based systems require expensive installations, hence making indoor localization an open problem. This dissertation consists of solving the problem of indoor localization by thoroughly exploiting the indoor ambient magnetic fields comprising mainly of disturbances termed as anomalies in the Earth's magnetic field caused by pillars, doors and elevators in hallways which are ferromagnetic in nature. By observing uniqueness in magnetic signatures collected from different campus buildings, the work presents the identification of landmarks and guideposts from these signatures and further develops magnetic maps of buildings - all of which can be used to locate and navigate people indoors. To understand the reason behind these anomalies, first a comparison between the measured and model generated Earth's magnetic field is made, verifying the presence of a constant field without any disturbances. Then by modeling the magnetic field behavior of different pillars such as steel reinforced concrete, solid steel, and other structures like doors and elevators, the interaction of the Earth's field with the ferromagnetic fields is described thereby explaining the causes of the uniqueness in the signatures that comprise these disturbances. Next, by employing the dynamic time warping algorithm to account for time differences in signatures obtained from users walking at different speeds, an indoor localization application capable of classifying locations using the magnetic signatures is developed solely on the smart phone. The application required users to walk short distances of 3-6 m anywhere in hallway to be located with accuracies of 80-99%. The classification framework was further validated with over 90% accuracies using model generated magnetic signatures representing

  9. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  10. Reducing indoor residential exposures to outdoor pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.

  11. Current implications of past DDT indoor spraying in Oman

    Czech Academy of Sciences Publication Activity Database

    Booji, P.; Holoubek, I.; Klánová, J.; Kohoutek, J.; Dvorská, Alice; Magulová, K.; Al-Zadjali, S.; Čupr, P.

    2016-01-01

    Roč. 550, apr (2016), s. 231-240 ISSN 0048-9697 Institutional support: RVO:67179843 Keywords : DDT * Residual indoor spraying * Human risk assessment * Cancer risk * Region-specific half-life Subject RIV: EH - Ecology, Behaviour Impact factor: 4.900, year: 2016

  12. [Health evaluation of fine particulate matter in indoor air].

    Science.gov (United States)

    2008-11-01

    When evaluating the health effects of indoor air fine particulate matter, the indoor dynamics as well as the physical, chemical and biological properties of fine particles have to be considered. The indoor air fraction PM2.5 largely stems from outdoor air. Accordingly, the German Working Group on Indoor Guideline Values of the Federal Environmental Agency and the States' Health Authorities also recommends WHO's (2006) 24-hour mean guideline value of 25 microg PM2,5 per cubic meter for indoor air evaluation. In contrast to PM2.5, coarse particles (PM10) in schools, kindergartens and dwellings show much higher indoor air concentrations. Additional sources indoors have to be assumed. Because of the different composition of indoor air compared to outdoor air and due to the lack of dose-response relationships of coarse particles in indoor air, the health effects of indoor air PM10 can not be evaluated yet. Sufficient and consistent ventilation is an indispensable basis to reduce PM concentrations in indoor spaces. Furthermore, known sources of PM indoors should be detected consequently and subsequently minimized.

  13. Pollution distribution and health risk assessment of heavy metals in indoor dust in Anhui rural, China.

    Science.gov (United States)

    Lin, Yuesheng; Fang, Fengman; Wang, Fei; Xu, Minglu

    2015-09-01

    Zn, Pb, Cu, Cr, V, Ni, Co, and As concentrations of indoor dust in Anhui rural were determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES). The degrees of metal pollution in indoor dust ranked as follows: Zn > Pb > Cr > Cu > V > Ni > Co > As, on average. The arithmetic means of Zn, Pb, Cu, Cr, V, Ni, Co, and As were 427.17, 348.73, 107.05, 113.68, 52.64, 38.93, 10.29, and 4.46 mg/kg, respectively. These were higher than background values of Anhui soil for Zn, Pb, Cu, Cr, and Ni, especially for Pb with the mean value of 13.21 times the background value. Heavy metal concentrations of indoor dust were different from different rural areas. House type (bungalows or storied house), sweeping frequency, and external environment around the house (such as the road grade) affected heavy metal concentrations in indoor dust. The results of factor analysis and correlation analysis indicated that Cu, Cr, Ni, Zn, and Co concentrations were mainly due to interior paint, metal objects, and building materials. Pb and As concentrations were due to vehicle emissions. V concentration was mainly of natural source. Average daily doses for the exposure pathway of the studied heavy metals decreased in children in the following order: hand-to-mouth ingestion > dermal contact > inhalation. The non-carcinogenic risks of heavy metals ranked as Pb > V > Cr > Cu > Zn > As > Co > Ni, and the carcinogenic risks of metals decreased in the order of Cr > Co > As > Ni. The non-carcinogenic hazard indexes and carcinogenic risks of metals in indoor dust were both lower than the safe values.

  14. Assessment of indoor radon doses received by the students in the Azad Kashmir schools (Pakistan)

    International Nuclear Information System (INIS)

    Rafique, M.; Rahman, S. U.; Rahman, S.; Matiullah; Shahzad, M. I.; Ahmed, N.; Iqbal, J.; Ahmed, B.; Ahmed, T.; Akhtar, N.

    2010-01-01

    Several epidemiological studies conducted on thousands of underground miners suggest that long-term exposure to high radon concentration can increase the risk of lung cancer. Keeping in view the importance of the subject, numerous studies throughout the world have been carried out to measure indoor radon concentration and its resulting doses at occupational and non-occupational sites. The purpose of the current study was to measure indoor radon concentration and its resulting doses received by the students of Azad Kashmir government schools. For this purpose, CR-39 radon detectors were installed in 80 carefully selected schools. The detectors were placed at a height of 3-5 ft. (depending upon average height of students in particular class) from the ground. After exposure of 90 d detectors were etched for 9 h in 6 M NaOH at 70 deg. C and the observed track densities were related to radon concentrations. The measured indoor radon concentration ranged from 22 ± 9 to 228 ± 3 Bq m -3 with a mean value of 78 ± 5 Bq m -3 . Based on the measured indoor radon data, the annual effective doses were found to vary from 0.55 ± 0.04 to 0.71 ± 0.03 mSv y -1 . The overall mean effective dose for the studied area was found to be 0.63 ± 0.04 mSv y -1 . Reported values for radon concentrations and corresponding doses are lower than ICRP recommended limits for workplaces. (authors)

  15. An Assessment of Indoor Air Quality before, during and after Unrestricted Use of E-Cigarettes in a Small Room

    Directory of Open Access Journals (Sweden)

    Grant O'Connell

    2015-05-01

    Full Text Available Airborne chemicals in the indoor environment arise from a wide variety of sources such as burning fuels and cooking, construction materials and furniture, environmental tobacco smoke as well as outdoor sources. To understand the contribution of exhaled e-cigarette aerosol to the pre-existing chemicals in the ambient air, an indoor air quality study was conducted to measure volatile organic compounds (including nicotine and low molecular weight carbonyls, polycyclic aromatic hydrocarbons, tobacco-specific nitrosamines and trace metal levels in the air before, during and after e-cigarette use in a typical small office meeting room. Measurements were compared with human Health Criteria Values, such as indoor air quality guidelines or workplace exposure limits where established, to provide a context for potential bystander exposures. In this study, the data suggest that any additional chemicals present in indoor air from the exhaled e-cigarette aerosol, are unlikely to present an air quality issue to bystanders at the levels measured when compared to the regulatory standards that are used for workplaces or general indoor air quality.

  16. An Assessment of Indoor Air Quality before, during and after Unrestricted Use of E-Cigarettes in a Small Room.

    Science.gov (United States)

    O'Connell, Grant; Colard, Stéphane; Cahours, Xavier; Pritchard, John D

    2015-05-06

    Airborne chemicals in the indoor environment arise from a wide variety of sources such as burning fuels and cooking, construction materials and furniture, environmental tobacco smoke as well as outdoor sources. To understand the contribution of exhaled e-cigarette aerosol to the pre-existing chemicals in the ambient air, an indoor air quality study was conducted to measure volatile organic compounds (including nicotine and low molecular weight carbonyls), polycyclic aromatic hydrocarbons, tobacco-specific nitrosamines and trace metal levels in the air before, during and after e-cigarette use in a typical small office meeting room. Measurements were compared with human Health Criteria Values, such as indoor air quality guidelines or workplace exposure limits where established, to provide a context for potential bystander exposures. In this study, the data suggest that any additional chemicals present in indoor air from the exhaled e-cigarette aerosol, are unlikely to present an air quality issue to bystanders at the levels measured when compared to the regulatory standards that are used for workplaces or general indoor air quality.

  17. Disparities and trends in indoor exposure to secondhand smoke among U.S. adolescents: 2000-2009.

    Directory of Open Access Journals (Sweden)

    Israel T Agaku

    Full Text Available INTRODUCTION: Secondhand smoke (SHS exposure causes disease and death among nonsmokers. With a plethora of smoke-free legislation implemented and a steady decrease in cigarette consumption noted over the past decade in the U.S., this study assessed trends in indoor SHS exposure among U.S. adolescents in grades 6-12 during 2000-2009. METHODS: Data were obtained from the 2000-2009 National Youth Tobacco Survey - a national survey of U.S. middle and high school students. SHS exposure within an indoor area within the past seven days was self-reported. Trends in indoor SHS exposure during 2000-2009 were assessed overall and by socio-demographic characteristics, using the Wald's test in a binary logistic regression. Within-group comparisons were performed using chi-squared statistics (p<0.05. RESULTS: The proportion of U.S. middle and high school students who were exposed to indoor SHS declined from 65.5% in 2000 to 40.5% in 2009 (p<0.05 for linear trend. Significant declines were also observed across all population subgroups. Between 2000 and 2009, prevalence of indoor SHS exposure declined significantly among both middle (58.5% to 34.3% and high school (71.5% to 45.4% students. Prevalence of indoor SHS exposure was significantly higher among girls (44.0% in 2009 compared to boys (37.2% in 2009 during each survey year. Similarly, prevalence of indoor SHS exposure during 2000-2009 was highest among non-Hispanic whites (44.2% in 2009 and lowest among non-Hispanic Asians (30.2% in 2009. During each survey year, prevalence was highest among the oldest age group (≥18 years and lowest among the youngest (9-11 years. Also, prevalence was significantly higher among current cigarette smokers (83.8% in 2009 compared to nonsmokers (34.0% in 2009. CONCLUSION: Significant declines in indoor SHS exposure among U.S. middle and high school students occurred during 2000-2009. While the results are encouraging, additional efforts are needed to further reduce youth

  18. NFC Internal: An Indoor Navigation System

    Directory of Open Access Journals (Sweden)

    Busra Ozdenizci

    2015-03-01

    Full Text Available Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability.

  19. Fieldwork measurement of indoor environmental quality (IEQ) in Malaysian platinum-rated green office buildings

    Science.gov (United States)

    Tharim, Asniza Hamimi Abdul; Samad, Muna Hanim Abdul; Ismail, Mazran

    2017-10-01

    An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.

  20. A holistic approach for the assessment of the indoor environmental quality, student productivity, and energy consumption in primary schools.

    Science.gov (United States)

    Dorizas, Paraskevi Vivian; Assimakopoulos, Margarita-Niki; Santamouris, Mattheos

    2015-05-01

    The perception of the indoor environmental quality (IEQ) through questionnaires in conjunction with in-field measurements related to the indoor air quality (IAQ), the thermal comfort and the lighting environment were studied in nine naturally ventilated schools of Athens, Greece. Cluster analysis was carried out in order to determine the ranges of indoor air pollutants, temperature (T), relative humidity (RH), and ventilation rates at which the students were satisfied with the indoor environment. It was found that increased levels of particulate matter did not have a negative effect on students' perception while students seemed to link the degradation of IAQ with temperature variations. Statistically significant correlations were further found between measurement results and students' perception of the IEQ. Students' sick building syndrome (SBS) symptoms and performance of schoolwork were also investigated as a function of the levels of indoor air pollutants and ventilation, and there were found significant positive correlations between particulate matter (PM) and certain health symptoms. Students' learning performance seemed to be affected by the ventilation rates and carbon dioxide (CO₂) concentrations while certain health effects positively correlated to the levels of PM and CO₂. The energy consumption of schools was rather low compared to other national findings, and both the electricity and oil consumption for heating positively correlated to the levels of indoor air pollutants.

  1. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  2. Semivolatile organic compounds in indoor environments

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Nazaroff, W.W.

    2008-01-01

    Semivolatile organic compounds (SVOCs) are ubiquitous in indoor environments, redistributing from their original sources to all indoor surfaces. Exposures resulting from their indoor presence contribute to detectable body burdens of diverse SVOCs, including pesticides, plasticizers, and flame ret...... remarkably well with levels measured in dermal hand wipes for SVOCs possessing a wide range of octanol-air partition coefficients....

  3. A Semantic-Based Indexing for Indoor Moving Objects

    OpenAIRE

    Tingting Ben; Xiaolin Qin; Ning Wang

    2014-01-01

    The increasing availability of indoor positioning, driven by techniques like RFID, Bluetooth, and smart phones, enables a variety of indoor location-based services (LBSs). Efficient queries based on semantic-constraint in indoor spaces play an important role in supporting and boosting LBSs. However, the existing indoor index techniques cannot support these semantic constraints-based queries. To solve this problem, this paper addresses the challenge of indexing moving objects in indoor spaces,...

  4. Indoor Positioning using Wi-Fi

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Krarup, Mads Vering; Stisen, Allan

    The past decade has witnessed substantial research on methods for indoor Wi-Fi positioning. While much effort has gone into achieving high positioning accuracy and easing fingerprint collection, it is our contention that the general problem is not sufficiently well understood, thus preventing...... deployments and their usage by applications to become more widespread. Based on our own and published experiences on indoor Wi-Fi positioning deployments, we hypothesize the following: Current indoor Wi-Fi positioning systems and their utilization in applications are hampered by the lack of understanding...... of the requirements present in the real-world deployments. In this paper, we report findings from qualitatively studying organisational requirements for indoor Wi-Fi positioning. The studied cases and deployments cover both company and public-sector settings and the deployment and evaluation of several types...

  5. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  6. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  7. Indoor Climate of Large Glazed Spaces

    DEFF Research Database (Denmark)

    Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per

    In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate it is crui...... it is cruicial at the design stage to be able to predict the performance regarding thermal comfort and energy consumption. This paper focus on the practical implementation of Computational Fluid Dynamics (CFD) and the relation to other simulation tools regarding indoor climate.......In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate...

  8. Knowledge and perceptions about indoor residual spray for malaria ...

    African Journals Online (AJOL)

    Background: Malaria control and intervention tools usage and coverage in community depend on community acceptability and compliance. Indoor residual spray (IRS) and long lasting insecticide treated nets (LLINs) are the preferred and recommended intervention tools. This study assessed the knowledge and perceptions ...

  9. Indoor air quality vs. energy use in a beer brewery : assessment of ventilation methods and systems using CFD

    NARCIS (Netherlands)

    van Hooff, T.A.J.; Blocken, B.J.E.

    2015-01-01

    The production in industrial buildings can have a large impact on the indoor air quality. For example, in beer breweries several processes influence the indoor air quality to a large extent, such as the fermentation process, which is accompanied by a strong emission of CO2 gas. Employees working

  10. Monitoring, Human Health Risk Assessment and Optimized Management for Typical Pollutants in Indoor Air from Random Families of University Staff, Wuhan City, China

    Directory of Open Access Journals (Sweden)

    Xiyao Chen

    2017-06-01

    Full Text Available In this study, 31 workers at a university were randomly selected for indoor environmental monitoring in Wuhan. Two indicators, formaldehyde and total volatile organic compounds (TVOC, and using 139 monitoring points, monitored the indoor environment (including home and workplace as well as the interior space of the main furniture. This study carried out the environmental quality assessment for TVOC based on the dB index method and the health risk assessment of indoor formaldehyde for the university staff receptors and, then focused on health risk in home environment to carry out detailed environmental health management. The results showed that TVOC in the three types of home spaces exceeded about 80% of the national standard. The excessive formaldehyde ratios for kitchens (79%, bedrooms (77% and living rooms (74% were calculated. Formaldehyde health risks all exceeded the United States Environmental Protection Agency, (USEPA acceptable risk threshold. The formaldehyde concentrations in workplaces were about 0.03 mg·m−3. While the risk contribution of the home environment to the total average health risk (0.0014, whether male and female is about 96%. For the adapted and unadapted persons, 90% and 55% of the monitoring points were located within the long-term tolerable range of TVOC decibel application, respectively. Long-term exposure to such an environment can lead to the Sick Building Syndrome (SBS. On the other hand, through comparison of the concentration of pollutants in the interior spaces of furniture and home spaces, it was determined tentatively that the pollutants were mainly concentrated in rarely used furniture. In summary, the air pollution in the studied homes of university staff was much serious than that in workplaces, which showed a need to manage TVOC and formaldehyde pollution by the three means: the purchase of green products, removal of internal pollution from furniture, and creating a good indoor volatile diffusion

  11. Contribution of (222)Rn-bearing water to indoor radon and indoor air quality assessment in hot spring hotels of Guangdong, China.

    Science.gov (United States)

    Song, Gang; Wang, Xinming; Chen, Diyun; Chen, Yongheng

    2011-04-01

    This study investigates the contribution of radon ((222)Rn)-bearing water to indoor (222)Rn in thermal baths. The (222)Rn concentrations in air were monitored in the bathroom and the bedroom. Particulate matter (PM, both PM(10) and PM(2.5)) and carbon dioxide (CO(2)) were also monitored with portable analyzers. The bathrooms were supplied with hot spring water containing 66-260 kBq m(-3) of (222)Rn. The results show that the spray of hot spring water from the bath spouts is the dominant mechanism by which (222)Rn is released into the air of the bathroom, and then it diffuses into the bedroom. Average (222)Rn level was 110-410% higher in the bedrooms and 510-1200% higher in the bathrooms compared to the corresponding average levels when there was no use of hot spring water. The indoor (222)Rn levels were influenced by the (222)Rn concentrations in the hot spring water and the bathing times. The average (222)Rn transfer coefficients from water to air were 6.2 × 10(-4)-4.1 × 10(-3). The 24-h average levels of CO(2) and PM(10) in the hotel rooms were 89% and 22% higher than the present Indoor Air Quality (IAQ) standard of China. The main particle pollutant in the hotel rooms was PM(2.5). Radon and PM(10) levels in some hotel rooms were at much higher concentrations than guideline levels, and thus the potential health risks to tourists and especially to the hotel workers should be of great concern, and measures should be taken to lower inhalation exposure to these air pollutants. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    International Nuclear Information System (INIS)

    Cousins, Anna Palm

    2012-01-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical–chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK OA and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: ► A novel indoor-inclusive multimedia urban fate model is developed and applied. ► Emissions indoors may increase the urban chemical residence time. ► Indoor removal from surfaces constitutes an additional loss process

  13. Development of Indoor Air Pollution Concentration Prediction by Geospatial Analysis

    Directory of Open Access Journals (Sweden)

    Adyati Pradini Yudison

    2015-07-01

    Full Text Available People living near busy roads are potentially exposed to traffic-induced air pollutants. The pollutants may intrude into the indoor environment, causing health risks to the occupants. Prediction of pollutant exposure therefore is of great importance for impact assessment and policy making related to environmentally sustainable transport. This study involved the selection of spatial interpolation methods that can be used for prediction of indoor air quality based on outdoor pollutant mapping without indoor measurement data. The research was undertaken in the densely populated area of Karees, Bandung, Indonesia. The air pollutant NO2 was monitored in this area as a preliminary study. Nitrogen dioxide concentrations were measured by passive diffusion tube. Outdoor NO2 concentrations were measured at 94 locations, consisting of 30 roadside and 64 outdoor locations. Residential indoor NO2 concentrations were measured at 64 locations. To obtain a spatially continuous air quality map, the spatial interpolation methods of inverse distance weighting (IDW and Kriging were applied. Selection of interpolation method was done based on the smallest root mean square error (RMSE and standard deviation (SD. The most appropriate interpolation method for outdoor NO2 concentration mapping was Kriging with an SD value of 5.45 µg/m3 and an RMSE value of 5.45 µg/m3, while for indoor NO2 concentration mapping the IDW was best fitted with an RMSE value of 5.92 µg/m3 and an SD value of 5.92 µg/m3.

  14. Indoor Positioning Using GPS Revisited

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Blunck, Henrik; Godsk, Torben

    2010-01-01

    It has been considered a fact that GPS performs too poorly inside buildings to provide usable indoor positioning. We analyze results of a measurement campaign to improve on the understanding of indoor GPS reception characteristics. The results show that using state-of-the-art receivers GPS...... low signal-to-noise ratios, multipath phenomena or bad satellite constellation geometry. We have also measured the indoor performance of embedded GPS receivers in mobile phones which provided lower availability and accuracy than state-of-the-art ones. Finally, we consider how the GPS performance...

  15. Indoor Semantic Modelling for Routing: The Two-Level Routing Approach for Indoor Navigation

    Directory of Open Access Journals (Sweden)

    Liu Liu

    2017-11-01

    Full Text Available Humans perform many activities indoors and they show a growing need for indoor navigation, especially in unfamiliar buildings such as airports, museums and hospitals. Complexity of such buildings poses many challenges for building managers and visitors. Indoor navigation services play an important role in supporting these indoor activities. Indoor navigation covers extensive topics such as: 1 indoor positioning and localization; 2 indoor space representation for navigation model generation; 3 indoor routing computation; 4 human wayfinding behaviours; and 5 indoor guidance (e.g., textual directories. So far, a large number of studies of pedestrian indoor navigation have presented diverse navigation models and routing algorithms/methods. However, the major challenge is rarely referred to: how to represent the complex indoor environment for pedestrians and conduct routing according to the different roles and sizes of users. Such complex buildings contain irregular shapes, large open spaces, complicated obstacles and different types of passages. A navigation model can be very complicated if the indoors are accurately represented. Although most research demonstrates feasible indoor navigation models and related routing methods in regular buildings, the focus is still on a general navigation model for pedestrians who are simplified as circles. In fact, pedestrians represent different sizes, motion abilities and preferences (e.g., described in user profiles, which should be reflected in navigation models and be considered for indoor routing (e.g., relevant Spaces of Interest and Points of Interest. In order to address this challenge, this thesis proposes an innovative indoor modelling and routing approach – two-level routing. It specially targets the case of routing in complex buildings for distinct users. The conceptual (first level uses general free indoor spaces: this is represented by the logical network whose nodes represent the spaces and edges

  16. An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.

    2009-01-01

    Maintaining an acceptable indoor environmental quality (IEQ) for air-conditioned office buildings consumes a considerable amount of thermal energy. This study correlates thermal energy consumption with the overall occupant acceptance of IEQ in some air-conditioned offices. An empirical expression of an IEQ index associated with thermal comfort, indoor air quality, aural and visual comfort is used to benchmark the offices. Employing input parameters obtained from the building stocks of Hong Kong, the office portfolios regarding the thermal energy consumption and the IEQ index are determined by Monte Carlo simulations. In particular, an energy-to-acceptance ratio and an energy-to-IEQ improvement ratio are proposed to measure the performance of energy consumption for the IEQ in the air-conditioned offices. The ratios give the thermal energy consumption corresponding to a desirable percentage of IEQ acceptances and to an IEQ upgrade, respectively. The results showed a non-linear increasing trend of annual thermal energy consumption for IEQ improvement at the offices of higher IEQ benchmarks. The thermal energy consumption for visual comfort and indoor air quality would also be significant in these offices. This study provides useful information that incorporates the IEQ in air-conditioned offices into the development of performance evaluation measures for thermal energy consumption.

  17. A Hybrid 3D Indoor Space Model

    Directory of Open Access Journals (Sweden)

    A. Jamali

    2016-10-01

    Full Text Available GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM, Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.

  18. A national survey of young women's beliefs about quitting indoor tanning: implications for health communication messages.

    Science.gov (United States)

    Bleakley, Amy; Jordan, Amy; Ellithorpe, Morgan E; Lazovich, DeAnn; Grossman, Sara; Glanz, Karen

    2018-03-15

    Indoor tanning is a risk factor for melanoma among young white women. Health communications can be an effective way of reaching this population and promoting behavior change. The purpose of this study was (i) to investigate the associations between intention to quit indoor tanning and attitudes, normative pressure, and efficacy about quitting, and (ii) to identify beliefs about quitting indoor tanning that can be used to design effective health communication messages to reduce skin cancer risk. A national online survey was conducted with 279 non-Hispanic white women ages 18-25 in the USA who are indoor tanners. The survey, based on the reasoned action approach, assessed intention, attitudes, norms, and efficacy and their corresponding underlying beliefs related to quitting indoor tanning, along with other known covariates. Data were collected in November/December 2015. Intention to quit indoor tanning was significantly associated with attitudes, specifically with the beliefs that it would "reduce damage to skin" (increased intention) and "make me less happy" (decreased intention). While self-efficacy was not related to intention to quit indoor tanning, injunctive normative beliefs were with key referent groups including mothers, friends, and romantic partners. Messages aimed at discouraging indoor tanning among young, non-Hispanic, white women should highlight the salient belief that quitting indoor tanning will reduce skin damage, counter the belief that it will make them less happy, and highlight key people who would approve of them quitting indoor tanning.

  19. Problems In Indoor Mapping and Modelling

    Science.gov (United States)

    Zlatanova, S.; Sithole, G.; Nakagawa, M.; Zhu, Q.

    2013-11-01

    expected to arise because of social changes, technological advancements, or commercial interests. The motivation of this work is to define a set of research problems that are either being investigated or should be investigated. These will hopefully provide a framework for assessing progress and advances in indoor modelling. The framework will be developed in the form of a problem matrix, detailing existing and emerging problems, their solutions and present best practices. Once the framework is complete it will be published online so that the IMM community can discuss and modify it as necessary. When the framework has reached a steady state an empirical benchmark will be provided to test solutions to posed problems. A yearly evaluation of the problem matrix will follow, the results of which will be published.

  20. Indoor Tanning Is Not Safe

    Science.gov (United States)

    ... the sun is by using these tips for skin cancer prevention. Indoor tanning is not a safe way to get vitamin ... to previous findings on the association between indoor tanning and skin cancer. Only a small number of people reported ...

  1. An overview of thoron and its progeny in the indoor environment

    International Nuclear Information System (INIS)

    McLaughlin, J.

    2010-01-01

    An account is given of the behaviour of thoron and its progeny in the indoor environment. Emphasis is placed on the spatial distribution of these radionuclides in room air and on their interactions with indoor aerosols. How these aspects of thoron and progeny behaviour give rise to special problems for measuring them and assessing their radiological impact are described. Descriptions and comparisons are given of a range of thoron and progeny measurement techniques both passive and active. Recent progress in thoron dosimetry is described as well as compared with radon dosimetry. The results of some indoor thoron and progeny surveys carried out in different countries in recent years are given. As an example of this a summary account is presented of a recently concluded survey of thoron and its airborne progeny in over 200 houses in Ireland. (authors)

  2. Climate change consequences for the indoor environment

    NARCIS (Netherlands)

    Ariës, M.B.C.; Bluyssen, P.M.

    2009-01-01

    Scientists warn us about climate change and its effects on the outdoor environment. These effects can have significant consequences for the indoor environment, also in the Netherlands. Climate changes will affect different aspects of the indoor environment as well as the stakeholders of that indoor

  3. Measurements of MIMO Indoor Channels at 1800 MHz with Multiple Indoor and Outdoor Base Stations

    Directory of Open Access Journals (Sweden)

    Jaldén Niklas

    2007-01-01

    Full Text Available This paper proposes several configurations for multiple base stations in indoor MIMO systems and compares their performance. The results are based on channel measurements realized with a MIMO testbed. The receiver was moved along several routes and floors on an office building. Both outdoor and indoor locations are considered for the transmitters or base stations, which allow the analysis of not only indoor but also outdoor-to-indoor environment. The use of 2 base stations with different system level combinations of the two is analyzed. We show that the configuration with base station selection provides almost as good performance as a full water-filling scheme when the 2 base stations are placed at different locations. Also the spatial correlation properties for the different configurations are analyzed and the importance of considering path loss when evaluating capacity is highlighted.

  4. Indoor combustion and asthma.

    Science.gov (United States)

    Belanger, Kathleen; Triche, Elizabeth W

    2008-08-01

    Indoor combustion produces both gases (eg, nitrogen dioxide, carbon monoxide) and particulate matter that may affect the development or exacerbation of asthma. Sources in the home include both heating devices (eg, fireplaces, woodstoves, kerosene heaters, flued [ie, vented] or nonflued gas heaters) and gas stoves for cooking. This article highlights the recent literature examining associations between exposure to indoor combustion and asthma development and severity. Since asthma is a chronic condition affecting both children and adults, both age groups are included in this article. Overall, there is some evidence of an association between exposure to indoor combustion and asthma, particularly asthma symptoms in children. Some sources of combustion such as coal stoves have been more consistently associated with these outcomes than other sources such as woodstoves.

  5. Assessing and controlling risks from the emission of organic chemicals from construction products into indoor environments.

    Science.gov (United States)

    Brown, Veronica M; Crump, Derrick R; Harrison, Paul T C

    2013-12-01

    Construction products can be a significant source of indoor pollutants, including volatile organic compounds that may be a risk to the health and well-being of building occupants. There are currently a number of schemes for the labelling of products according to their potential to emit organic compounds. Assessment of the complex mixtures of compounds that may be released has mandated the development of test methods that allow the determination of the concentrations of the chemicals released from products in controlled test chamber environments. In response to concerns about the financial burden faced by manufacturers required to test products according to the various different labelling schemes currently in existence, the European Commission has investigated the scope for greater harmonisation. This initiative has sought to harmonise the process for the assessment of emissions data, complementing work led by the European standards organisation focussed on harmonising the test chamber procedures. The current labelling schemes have a range of requirements with respect to the number of chemicals to be quantified. A comparison of 13 schemes worldwide has identified 15 lists of target compounds, with a total of 611 chemicals occurring on at least one of the target lists. While harmonisation may clarify and perhaps simplify these requirements, at least in Europe, it can be expected that future changes to product formulations, the introduction of new products and our increasing knowledge about the potential risks to health, will require continued development of new and improved measurement techniques. There is, therefore, a particular challenge for analytical chemists to ensure the efficient provision of high quality emissions data and thereby ultimately enable effective control of risks to human health through the prevention or reduction of indoor air pollution.

  6. Plants for Sustainable Improvement of Indoor Air Quality.

    Science.gov (United States)

    Brilli, Federico; Fares, Silvano; Ghirardo, Andrea; de Visser, Pieter; Calatayud, Vicent; Muñoz, Amalia; Annesi-Maesano, Isabella; Sebastiani, Federico; Alivernini, Alessandro; Varriale, Vincenzo; Menghini, Flavio

    2018-04-10

    Indoor pollution poses a serious threat to human health. Plants represent a sustainable but underexploited solution to enhance indoor air quality. However, the current selection of plants suitable for indoors fails to consider the physiological processes and mechanisms involved in phytoremediation. Therefore, the capacity of plants to remove indoor air pollutants through stomatal uptake (absorption) and non-stomatal deposition (adsorption) remains largely unknown. Moreover, the effects of the indoor plant-associated microbiome still need to be fully analyzed. Here, we discuss how a combination of the enhanced phytoremediation capacity of plants together with cutting-edge air-cleaning and smart sensor technologies can improve indoor life while reducing energy consumption. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Outdoor and indoor air quality and cognitive ability in young children.

    Science.gov (United States)

    Midouhas, Emily; Kokosi, Theodora; Flouri, Eirini

    2018-02-01

    This study examined outdoor and indoor air quality at ages 9 months and 3 years and their association with cognitive ability at age 3 in England and Wales. Data from 8198 Millennium Cohort Study children were analysed using multilevel regression. Outdoor air quality was assessed with mean annual estimates of nitrogen dioxide (NO 2 ) levels within a standard small area (ward). Indoor air quality was measured with parent-reports of damp or condensation in the home and exposure to secondhand smoke in the home. Cognitive ability was assessed with the British Ability Scales Naming Vocabulary subscale and the Bracken School Readiness Assessment. In adjusted models, consistent exposure to high levels of NO 2 at age 9 months and age 3 years was associated with lower verbal ability at age 3 years. Damp/condensation and secondhand smoke in the home at either age or at both ages were correlated with lower school readiness at age 3 years. Exposures to damp/condensation at age 3 years or at both ages and secondhand smoke at either age or at both ages were associated with lower verbal ability at age 3 years. Young children's exposures to indoor damp or condensation and secondhand smoke are likely to be detrimental for their cognitive outcomes. However, there do not appear to be any short-term effects of NO 2 . Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Characterizing the source of radon indoors

    International Nuclear Information System (INIS)

    Nero, A.V.; Nazaroff, W.W.

    1983-09-01

    Average indoor radon concentrations range over more than two orders of magnitude, largely because of variability in the rate at which radon enters from building materials, soil, and water supplies. Determining the indoor source magnitude requires knowledge of the generation of radon in source materials, its movement within materials by diffusion and convection, and the means of its entry into buildings. This paper reviews the state of understanding of indoor radon sources and transport. Our understanding of generation rates in and movement through building materials is relatively complete and indicates that, except for materials with unusually high radionuclide contents, these sources can account for observed indoor radon concentrations only at the low end of the range observed. Our understanding of how radon enters buildings from surrounding soil is poorer, however recent experimental and theoretical studies suggest that soil may be the predominant source in many cases where the indoor radon concentration is high. 73 references, 3 figures, 1 table

  9. Indoor Air Quality in Brazilian Universities

    Directory of Open Access Journals (Sweden)

    Sonia R. Jurado

    2014-07-01

    Full Text Available This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC (n = 15 and naturally ventilated (NV (n = 15 classrooms. The parameters of interest were indoor carbon dioxide (CO2, temperature, relative humidity (RH, wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively. The average indoor airborne dust concentration exceeded the Brazilian standards (<80 µg/m3 in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively. The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  10. Indoor Air Quality and Thermal Comfort in School Buildings

    Science.gov (United States)

    Juhásová Šenitková, Ingrid

    2017-12-01

    This paper presents results to thermal comfort and environment quality questions in 21 school building rooms. Results show that about 80% of the occupants expressed satisfaction with their thermal comfort in only 11% of the buildings surveyed. Air quality scores were somewhat higher, with 26% of buildings having 80% or occupant satisfaction. With respect to thermal comfort and air quality performance goals set out by standards, most buildings appear to be falling far short. Occupant surveys offer a means to systematically measure this performance, and also to provide diagnostic information for building designers and operators. The odours from building materials as well as human odours were studied by field measurement. The odour intensity and indoor air acceptability were assessed by a sensory panel. The concentrations of total volatile organic compounds and carbon dioxide were measured. The odours from occupancy and building materials were studied under different air change rate. The case study of indoor air acceptability concerning to indoor odours and its effect on perceived air quality are also presented in this paper.

  11. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  12. Indoor-breeding of Aedes albopictus in northern peninsular Malaysia and its potential epidemiological implications.

    Science.gov (United States)

    Dieng, Hamady; Saifur, Rahman G M; Hassan, Ahmad Abu; Salmah, M R Che; Boots, Michael; Satho, Tomomitsu; Jaal, Zairi; AbuBakar, Sazaly

    2010-07-27

    The mosquito Ae. albopictus is usually adapted to the peri-domestic environment and typically breeds outdoors. However, we observed its larvae in most containers within homes in northern peninsular Malaysia. To anticipate the epidemiological implications of this indoor-breeding, we assessed some fitness traits affecting vectorial capacity during colonization process. Specifically, we examined whether Ae. albopictus exhibits increased survival, gonotrophic activity and fecundity due to the potential increase in blood feeding opportunities. In a series of experiments involving outdoors and indoors breeding populations, we found that Ae. albopictus lives longer in the indoor environment. We also observed increased nighttime biting activity and lifetime fecundity in indoor/domestic adapted females, although they were similar to recently colonized females in body size. Taken together these data suggest that accommodation of Ae. albopictus to indoor/domestic environment may increase its lifespan, blood feeding success, nuisance and thus vectorial capacity (both in terms of increased vector-host contacts and vector population density). These changes in the breeding behavior of Ae. albopictus, a potential vector of several human pathogens including dengue viruses, require special attention.

  13. Perceived indoor air quality and its relationship to air pollutants in French dwellings.

    Science.gov (United States)

    Langer, S; Ramalho, O; Le Ponner, E; Derbez, M; Kirchner, S; Mandin, C

    2017-11-01

    Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM 10 and PM 2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Indoor environment program. 1994 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1995-04-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  15. Indoor environment program - 1995 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1996-06-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  16. Exposure assessment of organophosphorus and organobromine flame retardants via indoor dust from elementary schools and domestic houses.

    Science.gov (United States)

    Mizouchi, Shigekazu; Ichiba, Masayoshi; Takigami, Hidetaka; Kajiwara, Natsuko; Takamuku, Toshiyuki; Miyajima, Toru; Kodama, Hiroki; Someya, Takashi; Ueno, Daisuke

    2015-03-01

    To assess the exposure of flame retardants (FRs) for school-children, organophosphorus flame retardants and plasticizers (PFRs) and organobromine flame retardants (BFRs) were determined in the indoor dust samples collected from elementary schools and domestic houses in Japan in 2009 and 2010. PFRs were detected in all the dust samples analyzed and the highest concentration of total PFRs was thousand-fold higher than that of BFRs. Among the PFRs, tris(butoxyethyl)phosphate (TBOEP) showed the highest concentration with a median (med.) of 270,000 ng g(-1) dry weight (3700-5,500,000 ng g(-1) dry weight), followed by tris(methylphenyl)phosphate (TMPPs)>triphenyl phosphate (TPHP)=tris(1,3-dichloro-2-propyl)phosphate (TDCIPP)=tris(2-chloroisopropyl)phosphate (TCIPP)=tris(2chloroethyl)phosphate (TCEP)>ethylhexyl diphenyl phosphate (EHDPP). Significantly higher concentrations of TBOEP, tri-n-butyl phosphate (TNBP), TPHP, TMPPs, and total-PFRs were found in dust samples from elementary schools than from domestic houses. It might be due to that higher concentrations of TBOEP (as leveling agent) were detected from the floor polisher/wax products collected in those elementary schools. On the other hand, significantly higher concentrations of TCEP, TCIPPs, and total chloroalkyl-PFRs were found in domestic houses than in elementary schools. Exposure assessments of PFRs via indoor dust from elementary schools and domestic houses were conducted by calculating the hazard quotient (HQ). Among PFRs, HQs for TBOEP exceeded 1 (higher than reference dose: RfD) and its highest value was 1.9. To reduce the intake of TBOEP by school-children, it is recommended that the use of floor polisher/wax containing TBOEP be reduced in schools. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dutton, Spencer M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Barrios, Marcella [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Parthasarathy, Srinandini [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sidheswaran, Meera [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Katerina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-02-01

    California's building efficiency standards (Title 24) mandate minimum prescribed ventilation rates (VRs) for commercial buildings. Title 24 standards currently include a prescriptive procedure similar to ASHRAE’s prescriptive “ventilation rate procedure”, but does not include an alternative procedure, akin to ASHRAE’s non-prescriptive “indoor air quality procedure” (IAQP). The IAQP determines minimum VRs based on objectively and subjectively evaluated indoor air quality (IAQ). The first primary goal of this study was to determine, in a set of California retail stores, the adequacy of Title 24 VRs and observed current measured VRs in providing the level of IAQ specified through an IAQP process, The second primary goal was to evaluate whether several VRs implemented experimentally in a big box store would achieve adequate IAQ, assessed objectively and subjectively. For the first goal, a list of contaminants of concern (CoCs) and reference exposure levels (RELs) were selected for evaluating IAQ. Ventilation rates and indoor and outdoor CoC concentrations were measured in 13 stores, including one “big box” store. Mass balance models were employed to calculate indoor contaminant source strengths for CoCs in each store. Using these source strengths and typical outdoor air contaminant concentrations, mass balance models were again used to calculate for each store the “IAQP” VR that would maintain indoor CoC concentrations below selected RELs. These IAQP VRs were compared to the observed VRs and to the Title 24- prescribed VRs. For the second goal, a VR intervention study was performed in the big box store to determine how objectively assessed indoor contaminant levels and subjectively assessed IAQ varied with VR. The three intervention study VRs included an approximation of the store’s current VR [0.24 air changes per hour (ACH)], the Title 24-prescribed VR [0.69 ACH], and the calculated IAQPbased VR [1.51 ACH]). Calculations of IAQP-based VRs

  18. Indoor air quality issues related to the acquisition of conservation in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, M.C.; Hadley, D.L.; Marseille, T.J.

    1990-09-01

    The quality of indoor air in commercial buildings is dependent on the complex interaction between sources of indoor pollutants, environmental factors within buildings such as temperature and humidity, the removal of air pollutants by air-cleaning devices, and the removal and dilution of pollutants from outside air. To the extent that energy conservation measures (ECMs) may affect a number of these factors, the relationship between ECMs and indoor air quality is difficult to predict. Energy conservation measures may affect pollutant levels in other ways. Conservation measures, such as caulking and insulation, may introduce sources of indoor pollutants. Measures that reduce mechanical ventilation may allow pollutants to build up inside structures. Finally, heating, ventilation, and air-conditioning (HVAC) systems may provide surface areas for the growth of biogenic agents, or may encourage the dissemination of pollutants throughout a building. Information about indoor air quality and ventilation in both new and existing commercial buildings is summarized in this report. Sick building syndrome and specific pollutants are discussed, as are broader issues such as ventilation, general mitigation techniques, and the interaction between energy conservation activities and indoor air quality. Pacific Northwest Laboratory (PNL) prepared this review to aid the Bonneville Power Administration (Bonneville) in its assessment of potential environmental effects resulting from conservation activities in commercial buildings. 76 refs., 2 figs., 19 tabs.

  19. Indoor radon distribution of subway stations in a Korean major city

    International Nuclear Information System (INIS)

    Yoon, Seokwon; Chang, Byung-Uck; Kim, Yongjae; Byun, Jong-In; Yun, Ju-Yong

    2010-01-01

    The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 ± 14.7 Bq m -3 , and the range of values was from 9.4 to 98.2 Bq m -3 . The radon concentrations in groundwater (average 31.0 ± 0.8 Bq m -3 ) were not significantly high in most stations, but the concentration (177.9 ± 2.3 Bq L -1 ) of one station was over the level of 148 Bq L -1 in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y -1 , and 0.02 mSv y -1 , respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.

  20. Indoor radon distribution of subway stations in a Korean major city

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seokwon [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); Chang, Byung-Uck, E-mail: hafadai@kins.re.k [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of); Kim, Yongjae [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); Byun, Jong-In [University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of); Yun, Ju-Yong [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of)

    2010-04-15

    The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 +- 14.7 Bq m{sup -3}, and the range of values was from 9.4 to 98.2 Bq m{sup -3}. The radon concentrations in groundwater (average 31.0 +- 0.8 Bq m{sup -3}) were not significantly high in most stations, but the concentration (177.9 +- 2.3 Bq L{sup -1}) of one station was over the level of 148 Bq L{sup -1} in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y{sup -1}, and 0.02 mSv y{sup -1}, respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.

  1. The indoor UV tanning industry: a review of skin cancer risk, health benefit claims, and regulation.

    Science.gov (United States)

    Levine, Jody A; Sorace, Michael; Spencer, James; Siegel, Daniel M

    2005-12-01

    Nearly 30 million people tan indoors in the United States annually, including 2.3 million adolescents. Despite increased evidence on the dangers of artificial UV radiation, the popularity of indoor tanning is growing. We aim to assess the following 3 entities: (1) the association of indoor tanning with skin cancer; (2) statements regarding the health benefits of indoor tanning, especially regarding the production of vitamin D; and (3) current regulation of the tanning industry in the United States. We conducted a narrative review of the literature. Indoor tanning poses great risks. Studies support the role of artificial UV radiation in cutaneous carcinogenesis. Despite claims by the tanning industry, artificial tanning is not a safe or necessary way to increase systemic vitamin D levels. The National Institutes of Health and the World Health Organization have acknowledged the risks of indoor tanning. Nonetheless, regulations limiting tanning in the United States are surprisingly sparse. Systematic review of the literature was not performed. Health care providers must increase efforts to warn and educate the public and government about the dangers of UV radiation.

  2. The effect of the indoor environment on the fate of organic chemicals in the urban landscape.

    Science.gov (United States)

    Cousins, Anna Palm

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. In-plane user positioning indoors

    NARCIS (Netherlands)

    Jovanovic, N.; Özçelebi, T.; Lukkien, J.J.; Skoric, B.; Ignatenko, T.

    2014-01-01

    Indoor positioning is a service required by many smart environment applications for various purposes, such as activity classification, indoor navigation and context awareness. In this paper, we present a novel approach to the user positioning problem based on in-plane detection enabled by a set of

  4. Psychosocial dimensions of solving an indoor air problem.

    Science.gov (United States)

    Lahtinen, Marjaana; Huuhtanen, Pekka; Kähkönen, Erkki; Reijula, Kari

    2002-03-01

    This investigation focuses on the psychological and social dimensions of managing and solving indoor air problems. The data were collected in nine workplaces by interviews (n = 85) and questionnaires (n = 375). Indoor air problems in office environments have traditionally utilized industrial hygiene or technical expertise. However, indoor air problems at workplaces are often more complex issues to solve. Technical questions are inter-related with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the solving process are also put to the test. In the present study, the interviewees were very critical of the process of solving the indoor air problem. The responsibility for coordinating the problem-managing process was generally considered vague, as were the roles and functions of the various parties. Communication problems occurred and rumors about the indoor air problem circulated widely. Conflicts were common, complicating the process in several ways. The research focused on examining different ways of managing and resolving an indoor air problem. In addition, reference material on the causal factors of the indoor air problem was also acquired. The study supported the hypothesis that psychosocial factors play a significant role in indoor air problems.

  5. Assessment Framework of Building Facade in Optimizing Indoor Thermal Comfort of Green Building Index (GBI Certified Office Building

    Directory of Open Access Journals (Sweden)

    Abdul Tharim Asniza Hamimi

    2016-01-01

    Full Text Available During the past decade, the construction industry has seen a new trend in the development of “green” or “sustainable” construction concept around the world with vast support from prominent organization, together with the introduction of sustainable building codes. The establishment of green building certification systems worldwide is seen as one of the most efforts in the emerging green building movement. In order to support the development of the “green” and “sustainable” concept in Malaysia, Green Building Index (GBI was launched by the government on 21 May 2009 that created to promote sustainability in the built environment and raise awareness of environmental issues. However, the construction industry seems to have focused only on findings the “right mechanism” for an environmentally sustainable “final result” in order for the building to be certified as green with the lacking of continuous assessment on the building performance after the certifications. This study is purposely conducted to investigate the performance of various rated Green Building Index (GBI Non-Residential New Construction office buildings and the influence on Indoor Thermal Comfort (ITC of the selected buildings. The aim is to develop an assessment framework for optimum green building architectural façade to be used for office buildings in Malaysia as well as to analyse the occupants’ perception, satisfaction and performance in the selected Green Building Index (GBI rated office indoor environment. This research is still in its infancy; therefore the paper is focused on research aims, research scope and methodology, and expected deliverables for the proposed research.

  6. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report describes studies on the chemical and physical behavior of the [sup 218]Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and its dose to the cells in the respiratory tract are to be fully assessed. The specific tasks of the controlled laboratory studies are to determine the formation rates of [center dot]OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO[sub 2] ethylene, and H[sub 2]S to lower vapor pressure compounds and determine the role of gas phase additives such as H[sub 2]O and NH[sub 3] in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of [sup 218]Po[sub x][sup +] in O[sub 2] at low radon concentrations. Tasks of the exposure studies in occupied indoor spaces are to initiate measurements of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants, to initiate a prospective study of the utility of measurement of deposited [sup 210]Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon, and to develop the methodology to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  7. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, Anna Palm, E-mail: anna.cousins@ivl.se

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK{sub OA} and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: Black-Right-Pointing-Pointer A novel indoor-inclusive multimedia urban fate model is developed and applied. Black-Right-Pointing-Pointer Emissions indoors may increase the urban chemical residence time. Black

  8. Radiofrequency Field Distribution Assessment in Indoor Areas Covered by Wireless Local Area Network

    Directory of Open Access Journals (Sweden)

    HELBET, R.

    2009-02-01

    Full Text Available Electromagnetic environment becomes day by day more congested. Radio communication systems in the short range are now part of everyday life, and there is a need to also assess the pollution level due to their emission if we take into account human health and protection. There is consistent scientific evidence that environmental electromagnetic field may cause undesirable biological effects or even health hazards. Present paper aims at giving a view on exposure level due to wireless local area networks (WLAN emission solely, as part of environmental radiofrequency pollution. Highly accurate measurements were made indoor by using a frequency-selective measurement system and identifying the correct settings for an error-minimum assessment. We focused on analysis of the electric flux density distribution inside a room, in the far field of the emitting antennas, in case of a single network communication channel. We analyze the influence the network configuration parameters have on the field level. Distance from the source and traffic rate are also important parameters that affect the exposure level. Our measurements indicate that in the immediate vicinity of the WLAN stations the average field may reach as much as 13% from the present accepted reference levels given in the human exposure standards.

  9. Indoor Positioning System using Bluetooth

    OpenAIRE

    Sahil Puri

    2015-01-01

    This Paper on Bluetooth Indoor Positioning System is the intersection of Bluetooth Technology and Indoor Positioning Systems. Almost every smartphone today is Bluetooth enabled, making the use of the technology more flexible. We aim at using the RSSI value of Bluetooth signals to track the location of a device.

  10. Indoor air pollution: Sources and control. July 1988-January 1990 (Citations from the NTIS data base). Report for July 1988-January 1990

    International Nuclear Information System (INIS)

    1990-01-01

    This bibliography contains citations concerning indoor air pollution in residential, commercial, industrial, and institutional buildings. Indoor air quality assessment, health hazard evaluation, and contaminant identification and measurement are discussed. Indoor air pollution control methods and equipment are evaluated. Air quality analyses of energy efficient buildings are presented. Indoor air pollution from radon and asbestos are discussed in other bibliographies. (This updated bibliography contains 75 citations, 16 of which are new entries to the previous edition.)

  11. Risk assessment of exposure to radon concentration in indoor atmosphere and drinking water of Shimoga city, Karnataka, India

    International Nuclear Information System (INIS)

    Rangaswamy, D.R.; Sannappa, J.; Srinivasa, E.

    2016-01-01

    The exposure of population to natural sources of radiation has become an important issue in terms of radiological protection. The major contribution of dose from natural radiation in normal background regions arises due to inhalation of alpha-emitting radon and thoron, and their progenies, which are ubiquitous in both indoor and outdoor environs. The aim of the present study is to measure indoor radon, thoron and their progeny levels in the dwellings of Shimoga city and radon concentration in drinking water and to estimate the annual effective dose. The indoor concentration of radon, thoron and their progeny was measured using Solid-State Nuclear Track Detectors (SSNTDs) based twin chamber dosimeter cups. The 222 Rn concentration in drinking water was estimated by the Emanometry technique

  12. LADM and IndoorGML for Support of Indoor Space Identification

    Science.gov (United States)

    Zlatanova, S.; Van Oosterom, P. J. M.; Lee, J.; Li, K.-J.; Lemmen, C. H. J.

    2016-10-01

    Guidance and security in large public buildings such as airports, museums and shopping malls requires much more information that traditional 2D methods offer. Therefore 3D semantically-reach models have been actively investigated with the aim to gather knowledge about availability and accessibility of spaces. Spaces can be unavailable to specific users because of plenty of reasons: the 3D geometry of spaces (too low, too narrow), the properties of the objects to be guided to a specific part of the building (walking, driving, flying), the status of the indoor environment (e.g. crowded, limited light, under reconstruction), property regulations (private areas), security considerations and so on. However, such information is not explicitly avaible in the existing 3D semantically-reach models. IFC and CityGML are restricted to architectural building components and provide little to no means to describe such properties. IndoorGML has been designed to establish a generic approach for space identification allowing a space subdivision and automatic creation of a network for route computation. But currently it also represents only spaces as they are defined by the architectural layout of the building. The Land Administration Domain Model is currently the only available model to specify spaces on the basis of ownership and rights for use. In this paper we compare the principles of IndoorGML and LADM, investigate the approaches to define spaces and suggest options to the linking of the two types of spaces. We argue that LADM space subdivision on basis of properties and rights of use can be used to define to semantically and geometrically available and accessible spaces and therefore can enrich the IndoorGML concept.

  13. The Bonneville Power Administration new energy-efficient homes programs: Final environmental impact statement: Volume 1, Assessing indoor air quality options

    International Nuclear Information System (INIS)

    1988-03-01

    BPA has underway marketing and incentive programs to encourage the construction of new energy-efficient homes that comply with Model Conservation Standards (MCS) developed by the Northwest Power Planning Council. These homes are designed to have lower infiltration rates than current building practices provide, which is likely to contribute to increased levels of indoor air pollutants, and may adversely affect the health of occupants. BPA's current and past new homes programs maintained ventilation rates comparable to those found in current practice homes by requiring balanced mechanical ventilation. BPA now proposes to give builders and consumers more flexibility by increasing the options for protecting indoor air quality in its new homes programs. This proposal is the impetus for this Environmental Impact Statement (EIS), which was prepared for BPA by Pacific Northwest Laboratory. BPS is preparing this EIS to assess whether other techniques maintain indoor air quality comparable to that found in homes built using current practices. Although many pollutants are potentially of great concern, our analysis concentrates on radon and formaldehyde. It is based on measured concentrations of these pollutants and measured ventilation rates in current practice. Ventilation was measured using fan pressurization tests, which measure only air leakage, and perfluorocarbon tracer gas (PFT) tests, which account for ventilation from mechanical devices and occupant behavior in addition to air leakage. These tests yielded two different estimates. We used these data to estimate pollutant concentrations and lifetime cancer rates under three alternative actions. Under all of the alternatives, radon had a much greater effect than formaldehyde. 102 refs

  14. Development of an Indoor Location Based Service Test Bed and Geographic Information System with a Wireless Sensor Network

    Science.gov (United States)

    Jan, Shau-Shiun; Hsu, Li-Ta; Tsai, Wen-Ming

    2010-01-01

    In order to provide the seamless navigation and positioning services for indoor environments, an indoor location based service (LBS) test bed is developed to integrate the indoor positioning system and the indoor three-dimensional (3D) geographic information system (GIS). A wireless sensor network (WSN) is used in the developed indoor positioning system. Considering the power consumption, in this paper the ZigBee radio is used as the wireless protocol, and the received signal strength (RSS) fingerprinting positioning method is applied as the primary indoor positioning algorithm. The matching processes of the user location include the nearest neighbor (NN) algorithm, the K-weighted nearest neighbors (KWNN) algorithm, and the probabilistic approach. To enhance the positioning accuracy for the dynamic user, the particle filter is used to improve the positioning performance. As part of this research, a 3D indoor GIS is developed to be used with the indoor positioning system. This involved using the computer-aided design (CAD) software and the virtual reality markup language (VRML) to implement a prototype indoor LBS test bed. Thus, a rapid and practical procedure for constructing a 3D indoor GIS is proposed, and this GIS is easy to update and maintenance for users. The building of the Department of Aeronautics and Astronautics at National Cheng Kung University in Taiwan is used as an example to assess the performance of various algorithms for the indoor positioning system. PMID:22319282

  15. Development of an Indoor Location Based Service Test Bed and Geographic Information System with a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Shau-Shiun Jan

    2010-03-01

    Full Text Available In order to provide the seamless navigation and positioning services for indoor environments, an indoor location based service (LBS test bed is developed to integrate the indoor positioning system and the indoor three-dimensional (3D geographic information system (GIS. A wireless sensor network (WSN is used in the developed indoor positioning system. Considering the power consumption, in this paper the ZigBee radio is used as the wireless protocol, and the received signal strength (RSS fingerprinting positioning method is applied as the primary indoor positioning algorithm. The matching processes of the user location include the nearest neighbor (NN algorithm, the K-weighted nearest neighbors (KWNN algorithm, and the probabilistic approach. To enhance the positioning accuracy for the dynamic user, the particle filter is used to improve the positioning performance. As part of this research, a 3D indoor GIS is developed to be used with the indoor positioning system. This involved using the computer-aided design (CAD software and the virtual reality markup language (VRML to implement a prototype indoor LBS test bed. Thus, a rapid and practical procedure for constructing a 3D indoor GIS is proposed, and this GIS is easy to update and maintenance for users. The building of the Department of Aeronautics and Astronautics at National Cheng Kung University in Taiwan is used as an example to assess the performance of various algorithms for the indoor positioning system.

  16. Indoor-outdoor relationship of fungal aerosols in domestic homes situated in humid-warm climate

    International Nuclear Information System (INIS)

    ACeron Palma, I. M.; Lopez Pacheco, M.; Perez Sanchez, M. M.; Quintal Franco, C.; Giacoman Vallejos, G.; Ponce Caballero, C.

    2009-01-01

    Among the different kinds of bio aerosols, fungi represent a heterogeneous group, which plays an important role in human pathology. These microorganisms can be the cause of a variety of infectious diseases as well as allergic and toxic effects. Therefore, it is necessary to assess their composition and concentrations indoors, outdoors and in domestic environments. The study of indoor-air quality is a relatively new activity in the world, and very recent in Mexico. The aim of this study was to establish the relation between indoors and outdoors fungal aerosols in domestic homes. Air samples were collected, using the 6-stage Andersen impactor, inside and outside thirty domestic homes of Merida city, in Yucatan, Mexico. (Author)

  17. Humidification and perceived indoor air quality in the office environment.

    Science.gov (United States)

    Reinikainen, L M; Aunela-Tapola, L; Jaakkola, J J

    1997-01-01

    OBJECTIVE: To evaluate the effect of humidification on the odour, acceptability, and stuffiness of indoor air. METHODS: In a six period cross over trial at the Pasila Office Center, Helsinki, the air of two wings of the building in turn were ventilated with air of 30%-40% humidity. A third wing served as a non-humidified control area. The quality of indoor air was assessed weekly by a panel containing 18 to 23 members. The intraindividual differences in the ratings for odour, stuffiness, and acceptability between humidified and non-humidified wings were used to assess the effect of humidification. The roles of sex, current smoking, and age as potential effect modifiers were assessed by comparing the mean intraindividual differences in ratings between the groups. RESULTS: Humidified air was found to be more odorous and stuffy (paired t test P = 0.0001) and less acceptable than the non-humidified air (McNemar's test P humidification decreases the perceived air quality. This effect is strongest in women and young subjects. PMID:9196454

  18. Recognition, evaluation, and control of indoor air pollution

    International Nuclear Information System (INIS)

    Chastain, B.

    1993-01-01

    Indoor air pollution is typically associated with terms sick building syndrome, tight building syndrome, building related illness, and problem building. Indoor air pollution is a relatively new public health concern (approximately 15 years old) although this issue is an age-old problem dating back to prehistoric times when humans came to live indoors. This presentation summarizes indoor air quality issues in order to provide you with usable information concerning the recognition and evaluation of indoor air quality (IAQ) problems and the subsequent control measures which can be used for maintaining or improving the indoor air environment for better occupant health and comfort control. Why has the subject become so vocalized in the last fifteen years? Why the sudden interest and awareness concerning indoor air quality issues? During the last half of the 1970's and all of the 1980's, buildings were built or remodeled to minimize air handling, heating, and cooling costs, often limiting the amount of outside air brought into the buildings to near minimums. Paralleling these developments, complaints related to modern buildings increased. The new terms tight building syndrome, sick building syndrome, and indoor air quality became widely used by health and safety professionals and subsequently by newspaper columnist and the general public

  19. Providing better indoor environmental quality brings economicbenefits

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Seppanen, Olli

    2007-06-01

    This paper summarizes the current scientific evidence that improved indoor environmental quality can improve work performance and health. The review indicates that work and school work performance is affected by indoor temperature and ventilation rate. Pollutant source removal can sometimes improve work performance. Based on formal statistical analyses of existing research results, quantitative relationships are provided for the linkages of work performance with indoor temperature and outdoor air ventilation rate. The review also indicates that improved health and related financial savings are obtainable from reduced indoor tobacco smoking, prevention and remediation of building dampness, and increased ventilation. Example cost-benefit analyses indicate that many measures to improve indoor temperature control and increase ventilation rates will be highly cost effective, with benefit-cost ratios as high as 80 and annual economic benefits as high as $700 per person.

  20. Indoor air quality environmental information handbook: Combustion sources

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This environmental information handbook was prepared to assist both the non-technical reader (i.e., homeowner) and technical persons (such as researchers, policy analysts, and builders/designers) in understanding the current state of knowledge regarding combustion sources of indoor air pollution. Quantitative and descriptive data addressing the emissions, indoor concentrations, factors influencing indoor concentrations, and health effects of combustion-generated pollutants are provided. In addition, a review of the models, controls, and standards applicable to indoor air pollution from combustion sources is presented. The emphasis is on the residential environment. The data presented here have been compiled from government and privately-funded research results, conference proceedings, technical journals, and recent publications. It is intended to provide the technical reader with a comprehensive overview and reference source on the major indoor air quality aspects relating to indoor combustion activities, including tobacco smoking. In addition, techniques for determining potential concentrations of pollutants in residential settings are presented. This is an update of a 1985 study documenting the state of knowledge of combustion-generated pollutants in the indoor environment. 191 refs., 51 figs., 71 tabs.

  1. A Foundation for Efficient Indoor Distance-Aware Query Processing

    DEFF Research Database (Denmark)

    Lu, Hua; Cao, Xin; Jensen, Christian Søndergaard

    2012-01-01

    model that integrates indoor distance seamlessly. To enable the use of the model as a foundation for query processing, we develop accompanying, efficient algorithms that compute indoor distances for different indoor entities like doors as well as locations. We also propose an indexing framework......Indoor spaces accommodate large numbers of spatial objects, e.g., points of interest (POIs), and moving populations. A variety of services, e.g., location-based services and security control, are relevant to indoor spaces. Such services can be improved substantially if they are capable of utilizing...... that accommodates indoor distances that are pre-computed using the proposed algorithms. On top of this foundation, we develop efficient algorithms for typical indoor, distance-aware queries. The results of an extensive experimental evaluation demonstrate the efficacy of the proposals....

  2. Fungal pollution of indoor environments and its management.

    Science.gov (United States)

    Haleem Khan, A A; Mohan Karuppayil, S

    2012-10-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.

  3. Air Quality and Indoor Environmental Exposures: Clinical ...

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo

  4. Childhood asthma and indoor allergens in Native Americans in New York

    Directory of Open Access Journals (Sweden)

    Tarbell Alice

    2006-07-01

    Full Text Available Abstract Background The objective of this study was to assess the correlation between childhood asthma and potential risk factors, especially exposure to indoor allergens, in a Native American population. Methods A case-control study of St. Regis Mohawk tribe children ages 2–14 years, 25 diagnosed with asthma and 25 controls was conducted. Exposure was assessed based on a personal interview and measurement of mite and cat allergens (Der p 1, Fel d 1 in indoor dust. Results A non-significant increased risk of childhood asthma was associated with self-reported family history of asthma, childhood environmental tobacco smoke exposure, and air pollution. There was a significant protective effect of breastfeeding against current asthma in children less than 14 years (5.2 fold lower risk. About 80% of dust mite and 15% of cat allergen samples were above the threshold values for sensitization of 2 and 1 μg/g, respectively. The association between current asthma and exposure to dust mite and cat allergens was positive but not statistically significant. Conclusion This research identified several potential indoor and outdoor risk factors for asthma in Mohawks homes, of which avoidance may reduce or delay the development of asthma in susceptible individuals.

  5. Sources and concentrations of indoor nitrogen dioxide in Hamburg (west Germany) and Erfurt (east Germany)

    International Nuclear Information System (INIS)

    Cyrys, J.; Woelke, G.; Wichmann, H.E.; Heinrich, J.; Richter, K.

    2000-01-01

    Here we report indoor and outdoor concentrations of NO 2 for Erfurt and Hamburg and assess the contribution of the most important indoor sources (e.g. the presence of gas cooking ranges, smoking) and outdoor sources (traffic exhaust emissions). We examined the relative contribution of the different sources of NO 2 to the total indoor NO 2 levels in Erfurt and Hamburg. NO 2 indoor concentrations in Hamburg were slightly higher than those in Erfurt (i.e. living room: 15 μg m -3 for Erfurt and 17 μg m -3 for Hamburg). A linear regression model including the variables, place of residence, season and outdoor NO 2 levels, location of the home within the city, housing and occupant characteristics accounted for 38% of the NO 2 variance. The most important predictors of indoor NO 2 concentrations were gas in cooking followed by other characteristics, such as ventilation or outdoor NO 2 level. Residences in which gas was used for cooking, or in which occupants smoked, had substantially higher indoor NO 2 concentrations (41 or 18% increase, respectively). An increase in the outdoor NO 2 concentration from the 25th to the 75th-percentile (17 μg m -3 ) was associated with a 33% increase in the living room NO 2 concentration. Multiple regression analysis for both cities separately illustrated that use of gas for cooking was the major indoor source of NO 2 . This variable caused a similar increase in the indoor NO 2 levels in each city (43% in Erfurt and 47% in Hamburg). However, outdoor sources of NO 2 (motor vehicle traffic) contributed more to indoor NO 2 levels in Hamburg than in Erfurt

  6. Plants for Sustainable Improvement of Indoor Air Quality

    NARCIS (Netherlands)

    Brilli, Federico; Fares, Silvano; Ghirardo, Andrea; Visser, de Pieter; Calatayud, Vicent; Muñoz, Amalia; Annesi-Maesano, Isabella; Sebastiani, Federico; Alivernini, Alessandro; Varriale, Vincenzo; Menghini, Flavio

    2018-01-01

    Indoor pollution poses a serious threat to human health. Plants represent a sustainable but underexploited solution to enhance indoor air quality. However, the current selection of plants suitable for indoors fails to consider the physiological processes and mechanisms involved in phytoremediation.

  7. Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self- and parent-administered questionnaires.

    Science.gov (United States)

    Lampi, Jussi; Ung-Lanki, Sari; Santalahti, Päivi; Pekkanen, Juha

    2018-02-09

    Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self- and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self- and parent administered questionnaires was generally indoor air quality. Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.

  8. Microbiological Indoor and Outdoor Air Quality of Two Major ...

    African Journals Online (AJOL)

    Both indoor and outdoor air samples were assessed monthly for the three (3) months in the wet season (June – August, 2010) and dry season (November 2010 - January 2011) using the settled plate methods. The study sites were divided into nine (9) units which include accident and emergency ward, laboratory, male ward ...

  9. Indoor Photography

    OpenAIRE

    Sagers, Stephen; Patterson, Ron

    2011-01-01

    Photography is the science of recording light in an artistic way to create a pleasing image. Indoor photography requires a photographer to become familiar with some of the built in functions of a camera.

  10. Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms.

    Science.gov (United States)

    Hayleeyesus, Samuel Fekadu; Ejeso, Amanuel; Derseh, Fikirte Aklilu

    2015-07-01

    The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels. The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. The range of bio-aerosols contamination detected in the dormitory rooms was 511-9960 CFU/m(3) for bacterial and 531-6568 CFU/m(3) for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

  11. Ozone and limonene in indoor air: a source of submicron particle exposure.

    Science.gov (United States)

    Wainman, T; Zhang, J; Weschler, C J; Lioy, P J

    2000-12-01

    overall particle exposure. This study provides data for assessing the impact of outdoor ozone on indoor particles. This is important to determine the efficacy of the mass-based particulate matter standards in protecting public health because the indoor secondary particles can vary coincidently with the variations of outdoor fine particles in summer.

  12. Accumulative effects of indoor air pollution exposure on leukocyte telomere length among non-smokers.

    Science.gov (United States)

    Lin, Nan; Mu, Xinlin; Wang, Guilian; Ren, Yu'ang; Su, Shu; Li, Zhiwen; Wang, Bin; Tao, Shu

    2017-08-01

    Indoor air pollution is an important environmental factor that contributes to the burden of various diseases. Long-term exposure to ambient air pollution is associated with telomere shortening. However, the association between chronic indoor air pollution from household fuel combustion and leukocyte telomere length has not been studied. In our study, 137 cancer-free non-smokers were recruited. Their exposure levels to indoor air pollution from 1985 to 2014 were assessed using a face-to-face interview questionnaire, and leukocyte telomere length (LTL) was measured using a monochrome multiplex quantitative PCR method. Accumulative exposure to solid fuel usage for cooking was negatively correlated with LTL. The LTL of residents who were exposed to solid fuel combustion for three decades (LTL = 0.70 ± 0.17) was significantly shorter than that of other populations. In addition, education and occupation were related to both exposure to solid fuel and LTL. Sociodemographic factors may play a mediating role in the correlation between leukocyte telomere length and environmental exposure to indoor air pollution. In conclusion, long-term exposure to indoor air pollution may cause LTL dysfunction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Indoor-breeding of Aedes albopictus in northern peninsular Malaysia and its potential epidemiological implications.

    Directory of Open Access Journals (Sweden)

    Hamady Dieng

    Full Text Available BACKGROUND: The mosquito Ae. albopictus is usually adapted to the peri-domestic environment and typically breeds outdoors. However, we observed its larvae in most containers within homes in northern peninsular Malaysia. To anticipate the epidemiological implications of this indoor-breeding, we assessed some fitness traits affecting vectorial capacity during colonization process. Specifically, we examined whether Ae. albopictus exhibits increased survival, gonotrophic activity and fecundity due to the potential increase in blood feeding opportunities. METHODOLOGY/PRINCIPAL FINDINGS: In a series of experiments involving outdoors and indoors breeding populations, we found that Ae. albopictus lives longer in the indoor environment. We also observed increased nighttime biting activity and lifetime fecundity in indoor/domestic adapted females, although they were similar to recently colonized females in body size. CONCLUSION/SIGNIFICANCE: Taken together these data suggest that accommodation of Ae. albopictus to indoor/domestic environment may increase its lifespan, blood feeding success, nuisance and thus vectorial capacity (both in terms of increased vector-host contacts and vector population density. These changes in the breeding behavior of Ae. albopictus, a potential vector of several human pathogens including dengue viruses, require special attention.

  14. Outdoor-indoor air pollution in urban environment: Challenges and opportunity

    Directory of Open Access Journals (Sweden)

    Dennis Y.C. eLeung

    2015-01-01

    Full Text Available With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the 21st century. Indoor air quality is affected by many factors including the type and running conditions of indoor pollution sources, ventilation conditions, as well as indoor activities. Studies revealed that the outdoor environment is also an important factor that cannot be neglected for indoor air quality studies. In this review, the indoor and outdoor air pollution relationships obtained from different studies are discussed in order to identify the key factors affecting the indoor air quality. As climate change is recognized as imposing impacts on the environment, how it affects the indoor air quality and the health impacts to the occupants will be evaluated in this paper. The major challenges and opportunities in indoor/outdoor air pollution studies will be highlighted.

  15. Scopulariopsis and scopulariopsis-like species from indoor environments

    Directory of Open Access Journals (Sweden)

    J.H.C. Woudenberg

    2017-09-01

    Full Text Available Scopulariopsis-like species are often reported from the indoor environment, as well as from clinical samples. The lack of type isolates and thorough phylogenetic studies in the Microascaceae hampered the correct identification of these isolates. Based on recent phylogenetic studies, which resulted in multiple name changes, the aim is to molecularly identify the Scopulariopsis and scopulariopsis-like species which occur in the indoor environment and give an overview of the current species in these genera and their habitats. Strains from the CBS culture collection were supplemented with almost 80 indoor strains of which the internal transcribed spacer 1 and 2 and intervening 5.8S nrDNA (ITS, beta-tubulin (tub2 and translation elongation factor 1-alpha (tef1 gene regions were sequenced for phylogenetic inference. The multi-gene phylogenies recognise 33 Microascus species and 12 Scopulariopsis species and showed that the recently established genus Fuscoannellis, typified by Scopulariopsis carbonaria, should be synonymized with the genus Yunnania. Seven new Microascus species, four new Scopulariopsis species, and one new Yunnania species, are described, and a new name in Microascus and two new name combinations (one in Microascus, and one in Yunnania are proposed. In the indoor environment 14 Microascus species and three Scopulariopsis species were found. Scopulariopsis brevicaulis (22 indoor isolates and Microascus melanosporus (19 indoor isolates are the most common indoor species, in number of isolates, followed by M. paisii (8 indoor isolates and S. candida (7 indoor isolates. A genus phylogeny based on the ITS, tef1 and the large subunit 28S nrDNA (LSU of the type or representative isolates of all here recognised species is provided depicting all species habitats. No correlation between phylogenetic relationship and habitat preference could be observed. Ten species which are found indoor are also found in relation with human-derived samples. A

  16. Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J. I.; Lopez, K.; Rickards, J.

    2011-01-01

    The results of six months of continuous measurement of the indoor radon concentration levels in the building where the Physics Institute 3 MV Pelletron particle accelerator is located are presented. This study has three major objectives: a) to know the actual values of the levels of indoor radon in this installation, where personnel spend many hours and sometimes days; b) assess the radiological risk from radon inhalation for personnel working permanently in the laboratory, as well as incidental users; and c) establish, if necessary, time limits for continuous permanence on the location for indoor radon exposure. Passive nuclear track detectors and dynamic systems were employed, covering six months (August, 2009 to January, 2010). For the calculation of internal dose the Radon Individual Dose Calculator was used. The results indicate that the indoor radon levels are below the US EPA recommended levels (400 Bq/m 3 ) in workplaces. The measurements help to establish levels for workplaces in Mexico. (Author)

  17. [Measurement of Chemical Compounds in Indoor and Outdoor Air in Chiba City Using Diffusive Sampling Devices].

    Science.gov (United States)

    Sakamoto, Hironari; Uchiyama, Shigehisa; Kihara, Akiko; Tsutake, Toyoshige; Bekki, Kanae; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2015-01-01

    Indoor air quality (IAQ) is a major concern, because people on average spend the vast majority of their time indoors and they are repeatedly exposed to indoor air pollutants. In this study, to assess indoor air quality in Chiba City, gaseous chemical compounds were surveyed using four types of diffusive sampler. Gaseous chemical compounds such as carbonyls, volatile organic compounds (VOC), acid gases, basic gases, and ozone were measured in indoor and outdoor air of 50 houses throughout Chiba City in winter and summer. Four types of diffusive sampler were used in this study: DSD-BPE/DNPH packed with 2,4-dinitrophenyl hydrazine and trans-1,2-bis(2-pyridyl)ethylene-coated silica for ozone and carbonyls; VOC-SD packed with Carboxen 564 particles for volatile organic compounds; DSD-TEA packed with triethanolamine-impregnated silica for acid gases; and DSD-NH3 packed with phosphoric acid-impregnated silica for basic gases. Almost all compounds in indoor air were detected at higher concentrations in summer than in winter. However, the nitrogen dioxide concentration in indoor air particularly increased only in winter, which well correlated with the formic acid concentration (correlation coefficient=0.974). The compound with the highest concentrations in indoor air was p-dichlorobenzene, with recorded levels of 13,000 μg m(-3) in summer and 1,100 μg m(-3) in winter in indoor air. p-Dichlorobenzene in summer and nitrogen dioxide in winter are detected at markedly high concentrations. Pollution control and continuous monitoring of IAQ are indispensable for human health.

  18. Respiratory Effects of Indoor Heat and the Interaction with Air Pollution in Chronic Obstructive Pulmonary Disease.

    Science.gov (United States)

    McCormack, Meredith C; Belli, Andrew J; Waugh, Darryn; Matsui, Elizabeth C; Peng, Roger D; Williams, D'Ann L; Paulin, Laura; Saha, Anik; Aloe, Charles M; Diette, Gregory B; Breysse, Patrick N; Hansel, Nadia N

    2016-12-01

    There is limited evidence of the effect of exposure to heat on chronic obstructive pulmonary disease (COPD) morbidity, and the interactive effect between indoor heat and air pollution has not been established. To determine the effect of indoor and outdoor heat exposure on COPD morbidity and to determine whether air pollution concentrations modify the effect of temperature. Sixty-nine participants with COPD were enrolled in a longitudinal cohort study, and data from the 601 participant days that occurred during the warm weather season were included in the analysis. Participants completed home environmental monitoring with measurement of temperature, relative humidity, and indoor air pollutants and simultaneous daily assessment of respiratory health with questionnaires and portable spirometry. Participants had moderate to severe COPD and spent the majority of their time indoors. Increases in maximal indoor temperature were associated with worsening of daily Breathlessness, Cough, and Sputum Scale scores and increases in rescue inhaler use. The effect was detected on the same day and lags of 1 and 2 days. The detrimental effect of temperature on these outcomes increased with higher concentrations of indoor fine particulate matter and nitrogen dioxide (P pollution concentrations. For patients with COPD who spend the majority of their time indoors, indoor heat exposure during the warmer months represents a modifiable environmental exposure that may contribute to respiratory morbidity. In the context of climate change, adaptive strategies that include optimization of indoor environmental conditions are needed to protect this high-risk group from the adverse health effects of heat.

  19. Evolution of Indoor Positioning Technologies: A Survey

    Directory of Open Access Journals (Sweden)

    Ramon F. Brena

    2017-01-01

    Full Text Available Indoor positioning systems (IPS use sensors and communication technologies to locate objects in indoor environments. IPS are attracting scientific and enterprise interest because there is a big market opportunity for applying these technologies. There are many previous surveys on indoor positioning systems; however, most of them lack a solid classification scheme that would structurally map a wide field such as IPS, or omit several key technologies or have a limited perspective; finally, surveys rapidly become obsolete in an area as dynamic as IPS. The goal of this paper is to provide a technological perspective of indoor positioning systems, comprising a wide range of technologies and approaches. Further, we classify the existing approaches in a structure in order to guide the review and discussion of the different approaches. Finally, we present a comparison of indoor positioning approaches and present the evolution and trends that we foresee.

  20. REVIEW OF QUANTITATIVE STANDARDS AND GUIDELINES FOR FUNGI IN INDOOR AIR

    Science.gov (United States)

    Exposure to fungal aerosols clearly causes human disease. However, methods for assessing exposure remain poorly understood, and guidelines for interpreting data are often contradictory. The purposes of this paper are to review and compare existing guidelines for indoor airborne...

  1. THE EXTRACTION OF INDOOR BUILDING INFORMATION FROM BIM TO OGC INDOORGML

    Directory of Open Access Journals (Sweden)

    T.-A. Teo

    2017-07-01

    Full Text Available Indoor Spatial Data Infrastructure (indoor-SDI is an important SDI for geosptial analysis and location-based services. Building Information Model (BIM has high degree of details in geometric and semantic information for building. This study proposed direct conversion schemes to extract indoor building information from BIM to OGC IndoorGML. The major steps of the research include (1 topological conversion from building model into indoor network model; and (2 generation of IndoorGML. The topological conversion is a major process of generating and mapping nodes and edges from IFC to indoorGML. Node represents every space (e.g. IfcSpace and objects (e.g. IfcDoor in the building while edge shows the relationships between nodes. According to the definition of IndoorGML, the topological model in the dual space is also represented as a set of nodes and edges. These definitions of IndoorGML are the same as in the indoor network. Therefore, we can extract the necessary data in the indoor network and easily convert them into IndoorGML based on IndoorGML Schema. The experiment utilized a real BIM model to examine the proposed method. The experimental results indicated that the 3D indoor model (i.e. IndoorGML model can be automatically imported from IFC model by the proposed procedure. In addition, the geometric and attribute of building elements are completely and correctly converted from BIM to indoor-SDI.

  2. Preventing Skin Cancer Through Reduction of Indoor Tanning

    Science.gov (United States)

    Watson, Meg; Holman, Dawn M.; Fox, Kathleen A.; Guy, Gery P.; Seidenberg, Andrew B.; Sampson, Blake P.; Sinclair, Craig; Lazovich, DeAnn

    2015-01-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. PMID:23683987

  3. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  4. Indoor air pollution in slum neighbourhoods of Addis Ababa, Ethiopia

    Science.gov (United States)

    Sanbata, Habtamu; Asfaw, Araya; Kumie, Abera

    2014-06-01

    An estimated 95% of the population of Ethiopia uses traditional biomass fuels, such as wood, dung, charcoal, or crop residues, to meet household energy needs. As a result of the harmful smoke emitted from the combustion of biomass fuels, indoor air pollution is responsible for more than 50,000 deaths annually and causes nearly 5% of the burden of disease in Ethiopia. Very limited research on indoor air pollution and its health impacts exists in Ethiopia. This study was, therefore, undertaken to assess the magnitude of indoor air pollution from household fuel use in Addis Ababa, the capital city of Ethiopia. During January and February, 2012, the concentration of fine particulate matter (PM2.5) in 59 households was measured using the University of California at Berkeley Particle Monitor (UCB PM). The raw data was analysed using Statistical Package of Social Science (SPSS version 20.0) software to determine variance between groups and descriptive statistics. The geometric mean of 24-h indoor PM2.5 concentration is approximately 818 μg m-3 (Standard deviation (SD = 3.61)). The highest 24-h geometric mean of PM2.5 concentration observed were 1134 μg m-3 (SD = 3.36), 637 μg m-3 (SD = 4.44), and 335 μg m-3 (SD = 2.51), respectively, in households using predominantly solid fuel, kerosene, and clean fuel. Although 24-h mean PM2.5 concentration between fuel types differed statistically (P 0.05). The study revealed indoor air pollution is a major environmental and health hazard from home using biomass fuel in Addis Ababa. The use of clean fuels and efficient cooking stoves is recommended.

  5. Assessment of current techniques for reduction of indoor radon concentration in existing and new houses in European countries

    International Nuclear Information System (INIS)

    Holmgren, O.; Arvela, H.

    2012-03-01

    Radon control technologies aim at the reduction of indoor radon concentrations in existing buildings and in new construction through remedial and preventive measures. In recent years, rising ecological awareness and rising energy costs have stimulated the development of low energy and passive houses to save energy. This report contains the analysis and assessment of current techniques and technologies used to achieve the reduction of indoor radon concentrations in existing and new houses with regard to the reduction efficiency and potential impact on energy consumption (qualitative analysis). A questionnaire was prepared and sent to all RADPAR partners in 14 different countries in order to gather national information about the current remediation and prevention techniques. Responses with variable amounts of information were obtained. Based on the questionnaire responses, the status of radon remediation and prevention in each country was assessed, in addition to the reduction efficiency and potential impact on energy consumption of the current remediation and prevention techniques. The number of dwellings with an elevated indoor radon concentration typically ranges from tens of thousands to a million. The percentage of these houses already remediated varies from zero to 15%. Preventive measures in new construction have been taken from a small number of houses to over half a million houses. The research data on the current situation, the number of houses with preventive measures and the efficiency of these measures is currently still quite inadequate. Assessment of the techniques and also the surveys aiming at exploring the impact of remedial and preventive measures is greatly needed in order to promote the work at the national level. The most efficient remediation method is the active sub-slab depressurization (SSD) and the radon well, for which the reduction in the radon concentration is typically 70 - 95%. Other methods, such as sealing entry routes and improving

  6. Designing Indoor Climate. A Thesis on the Integration of Indoor Climate Analysis in Architectural Design

    Energy Technology Data Exchange (ETDEWEB)

    Den Hartog, J.P.

    2003-12-01

    In contemporary architecture education, indoor climate and building installations suffer from a lack of popularity. Students of architecture, filled with great expectations and awe for the famous designers of the 20th century, find inspiration in examples such as Le Corbusier's Villa Savoy, Lloyd Wright's falling water or the Rietveld's Schroder house. Recognizable as this may be, great aesthetics constitute only a small part of creating architecture. The process of designing and constructing buildings comprises the involvement of a multitude of skills such as creating clear functional layouts, designing solid structures and taking care of healthy indoor climates. Most textbooks and magazines contemporary architecture do not cover the less attractive aspects of the indoor climate such as heating, ventilation and cooling unless these services form an important part of the buildings aesthetic identity. Recent examples regarding the integration of second skin facades and natural ventilation in indoor climate, sometimes fail to convince as a result of the lack of thorough evaluations and detailed information.

  7. Indoor air quality in a restaurant kitchen using margarine for deep-frying.

    Science.gov (United States)

    Sofuoglu, Sait C; Toprak, Melis; Inal, Fikret; Cimrin, Arif H

    2015-10-01

    Indoor air quality has a great impact on human health. Cooking, in particular frying, is one of the most important sources of indoor air pollution. Indoor air CO, CO2, particulate matter (PM), and volatile organic compound (VOC) concentrations, including aldehydes, were measured in the kitchen of a small establishment where a special deep-frying margarine was used. The objective was to assess occupational exposure concentrations for cooks of such restaurants. While individual VOC and PM2.5 concentrations were measured before, during, and after frying events using active sampling, TVOC, PM10, CO, CO2, temperature, and relative humidity were continuously monitored through the whole period. VOC and aldehyde concentrations did not increase to considerable levels with deep-frying compared to the background and public indoor environment levels, whereas PM10 increased significantly (1.85 to 6.6 folds). The average PM2.5 concentration of the whole period ranged between 76 and 249 μg/m(3). Hence, considerable PM exposures could occur during deep-frying with the special margarine, which might be sufficiently high to cause health effects on cooks considering their chronic occupational exposures.

  8. Effect of using low-polluting building materials and increasing ventilation on perceived indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Wargocki, P.; Zuczek, P. (International Centre for Indoor Environment and Energy, Dept. of Mechanical Engineering, DTU, Kgs. Lyngby (DK)); Knudsen, Henrik N. (Danish Building Research Institute, Aalborg Univ., Hoersholm (DK))

    2007-07-01

    The potential of improving perceived air quality indoors was quantified when low-polluting materials are used and when building ventilation is increased. This was done by studying the relationships between ventilation rate and the perceived indoor air quality. A sensory panel assessed the air quality in test rooms ventilated with realistic outdoor air supply rates, where combinations of high- and low-polluting wall, floor and ceiling materials were set up. These materials were ranked as high- and low-polluting using sensory assessments of air quality in small-scale glass chambers, where they were tested individually. Substituting materials ranked as high-polluting with materials ranked as lower-polluting improved the perceived air quality in the test rooms. This improvement was greater than what was achieved by a realistic increase of the ventilation rate in the test rooms. Thus reducing pollution emitted from building materials that affects the perceived air quality has a considerable potential of limiting the energy for ventilation without compromising indoor air quality. (au)

  9. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  10. Accumulative effects of indoor air pollution exposure on leukocyte telomere length among non-smokers

    International Nuclear Information System (INIS)

    Lin, Nan; Mu, Xinlin; Wang, Guilian; Ren, Yu'ang; Su, Shu; Li, Zhiwen; Wang, Bin; Tao, Shu

    2017-01-01

    Indoor air pollution is an important environmental factor that contributes to the burden of various diseases. Long-term exposure to ambient air pollution is associated with telomere shortening. However, the association between chronic indoor air pollution from household fuel combustion and leukocyte telomere length has not been studied. In our study, 137 cancer-free non-smokers were recruited. Their exposure levels to indoor air pollution from 1985 to 2014 were assessed using a face-to-face interview questionnaire, and leukocyte telomere length (LTL) was measured using a monochrome multiplex quantitative PCR method. Accumulative exposure to solid fuel usage for cooking was negatively correlated with LTL. The LTL of residents who were exposed to solid fuel combustion for three decades (LTL = 0.70 ± 0.17) was significantly shorter than that of other populations. In addition, education and occupation were related to both exposure to solid fuel and LTL. Sociodemographic factors may play a mediating role in the correlation between leukocyte telomere length and environmental exposure to indoor air pollution. In conclusion, long-term exposure to indoor air pollution may cause LTL dysfunction. - Highlights: • This is the first study to investigate a clear association between indoor air pollution and leukocyte telomere length. • Chronic exposure to household solid fuel combustion and leukocyte telomere length presented a negative correlation. • Shortest leukocyte telomere length belonged to population cooking for longest time. • Education and occupation were remarkably associated with leukocyte telomere length via relating with indoor air pollution. - Long-term exposure to household solid fuel combustion is negatively associated with LTL.

  11. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    Science.gov (United States)

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  12. SVOC exposure indoors: fresh look at dermal pathways.

    Science.gov (United States)

    Weschler, C J; Nazaroff, W W

    2012-10-01

    typically not taken into account in exposure assessments. Yet, for certain SVOCs, intake through skin is estimated to be substantially larger than intake through inhalation. Exposure scientists, risk assessors, and public health officials should be mindful of the dermal pathway when estimating exposures to indoor SVOCs. Also, they should recognize that health consequences vary with exposure pathway. For example, an SVOC that enters the blood through the skin does not encounter the same detoxifying enzymes that an ingested SVOC would experience in the stomach, intestines, and liver before it enters the blood. © 2012 John Wiley & Sons A/S.

  13. Usability analysis of indoor map application in a shopping centre

    Science.gov (United States)

    Dewi, R. S.; Hadi, R. K.

    2018-04-01

    Although indoor navigation is still new in Indonesia, its future development is very promising. Similar to the outdoor one, the indoor navigation technology provides several important functions to support route and landmark findings. Furthermore, there is also a need that indoor navigation can support the public safety especially during disaster evacuation process in a building. It is a common that the indoor navigation technologies are built as applications where users can access this technology using their smartphones, tablets, or personal computers. Therefore, a usability analysis is important to ensure the indoor navigation applications can be operated by users with highest functionality. Among several indoor map applications which were available in the market, this study chose to analyse indoor Google Maps due to its availability and popularity in Indonesia. The experiments to test indoor Google Maps was conducted in one of the biggest shopping centre building in Surabaya, Indonesia. The usability was measured by employing System Usability Scale (SUS) questionnaire. The result showed that the SUS score of indoor Google Maps was below the average score of other cellular applications to indicate the users still had high difficulty in operating and learning the features of indoor Google Maps.

  14. Impacts of a new insurance benefit with capitated provider payment on healthcare utilization, expenditure and quality of medication prescribing in China

    NARCIS (Netherlands)

    Sun, Jing; Zhang, Xiaotian; Zhang, Zou; Wagner, Anita K.; Ross-Degnan, Dennis; Hogerzeil, Hans V.

    ObjectivesTo assess a new Chinese insurance benefit with capitated provider payment for common diseases in outpatients. MethodsLongitudinal health insurance claims data, health administrative data and primary care facility data were used to assess trajectories in outpatient visits, inpatient

  15. An architectural framework for 5G indoor communications

    NARCIS (Netherlands)

    Chandra, Kishor; Prasad, R. Venkatesha; Niemegeers, Ignas

    2015-01-01

    In this paper, we emphasize on indoor networks in 5G era. We explore the possible technologies and architectural solutions for 5G indoor communications. Owing to the fact that requirements for indoor and outdoor communications will be quite different in the next generation networks, we try to define

  16. Influence of indoor hygrothermal conditions on human quality of life in social housing

    Directory of Open Access Journals (Sweden)

    Sara Soares

    2015-11-01

    Full Text Available Background: Modern societies spend most of their time indoors, namely at home, and the indoor environment quality turns out to be a crucial factor to health, quality of life and well-being of the residents. The present study aims to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals’ health. Design and Methods: This study case will rely on the following assessments in both rehabilitated and non-rehabilitated social housing: i field measurements, in social dwellings (namely temperature, relative humidity, carbon dioxide concentration, air velocity, air change rate, level of mould spores and energy consumption; ii residents’ questionnaires on social, demogaphic, behavioural, health characteristics and quality of life. Also, iii qualitative interviews performed with social housing residents from the rehabilitated houses, addressing the self-perception of living conditions and their influence in health status and quality of life. All the collected information will be combined and analysed in order to achieve the main objective. Expected impact: It is expected to define a Predicted Human Life Quality (PHLQ index, that combines physical parameters describing the indoor environment measured through engineering techniques with residents’ and neighbourhood quality of life characteristics assessed by health questionnaires. Improvement in social housing should be related with better health indicators and the new index might be an important tool contributing to enhance quality of life of the residents.

  17. Influence of Indoor Hygrothermal Conditions on Human Quality of Life in Social Housing.

    Science.gov (United States)

    Soares, Sara; Fraga, Silvia; Delgado, Joao M P Q; Ramos, Nuno M M

    2015-11-17

    Modern societies spend most of their time indoors, namely at home, and the indoor environment quality turns out to be a crucial factor to health, quality of life and well-being of the residents. The present study aims to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals' health. This study case will rely on the following assessments in both rehabilitated and non-rehabilitated social housing: i) field measurements, in social dwellings (namely temperature, relative humidity, carbon dioxide concentration, air velocity, air change rate, level of mould spores and energy consumption); ii) residents' questionnaires on social, demogaphic, behavioural, health characteristics and quality of life. Also, iii) qualitative interviews performed with social housing residents from the rehabilitated houses, addressing the self-perception of living conditions and their influence in health status and quality of life. All the collected information will be combined and analysed in order to achieve the main objective. It is expected to define a Predicted Human Life Quality (PHLQ) index, that combines physical parameters describing the indoor environment measured through engineering techniques with residents' and neighbourhood quality of life characteristics assessed by health questionnaires. Improvement in social housing should be related with better health indicators and the new index might be an important tool contributing to enhance quality of life of the residents. Significance for public healthThis study will contribute to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals' health, in social housing neighbourhoods. As so, it is important to share the undertaken methodology carried out by a multidisciplinary team, in order to allow other researchers following comparable studies to adopt a similar approach. The case study results will allow

  18. Indoor air quality in hairdressing salons in Taipei.

    Science.gov (United States)

    Chang, C-J; Cheng, S-F; Chang, P-T; Tsai, S-W

    2018-01-01

    To improve indoor air quality and to protect public health, Taiwan has enacted the "Indoor Air Quality Act (IAQ Act)" in 2012. For the general public, the indoor air quality in hair salons is important because it is a popular location that people will often visit for hair treatments. However, only a few exposure assessments regarding air pollutants have previously been performed in hair salons. To assess the air quality of hairdressing environments in Taipei, ten hairdressing salons were included for a walk-through survey in this study. In addition, the airborne concentrations of formaldehyde, volatile organic compounds (VOCs), CO 2 , and phthalate esters were also determined in 5 salons. Charcoal, XAD-2, and OVS-Tenax tubes were used for the air sampling, while the samples were analyzed with gas chromatography/mass spectrometer. It was found that the products used in hair salons contained various chemicals. In fact, from the walk-through survey, a total of 387 different ingredients were found on 129 hair product labels. The hair salons were not well ventilated, with CO 2 levels of 600 to 3576 ppm. The formaldehyde concentrations determined in this study ranged from 12.40 to 1.04 × 10 3  μg m -3 , and the maximum level was above the permissible exposure limit (PEL) of US Occupational Safety and Health Administration (US OSHA). Additionally, 83% of the samples were with levels higher than the standard regulated by Taiwan's IAQ Act. The concentrations of VOCs and phthalate esters were below the occupational exposure limits (OELs), but higher than what was found in general residential environments. The hair products were considered as the major source of air pollutants because significantly higher concentrations were found around the working areas. The number of perming treatments, the number of workers, and the frequency of using formaldehyde releasing products, were found to be associated with the levels of formaldehyde. This study indicates that efforts are

  19. The correlation of Acanthamoeba from the ventilation system with other environmental parameters in commercial buildings as possible indicator for indoor air quality.

    Science.gov (United States)

    Ooi, Soo Shen; Mak, Joon Wah; Chen, Donald K F; Ambu, Stephen

    2017-02-07

    The free-living protozoan Acanthamoeba is an opportunistic pathogen that is ubiquitous in our environment. However, its role in affecting indoor air quality and ill-health of indoor occupants is relatively unknown. The present study investigated the presence of Acanthamoeba from the ventilation system and its correlation with other indoor air quality parameters, used in the industry code of practice and its potential as an indicator for indoor air quality. Indoor air quality assessments were carried out in nine commercial buildings with approval from the building management, and the parameters assessed were as recommended by the Department of Occupational Safety and Health. The presence of Acanthamoeba was determined through dust swabs from the ventilation system and indoor furniture. Logistic regression was performed to study the correlation between assessed parameters and occupants' complaints. A total of 107 sampling points were assessed and 40.2% of the supplying air diffuser and blowing fan and 15% of the furniture were positive for cysts. There was a significant correlation between Acanthamoeba detected from the ventilation system with ambient total fungus count (r=0.327; p=0.01) and respirable particulates (r=0.276; p=0.01). Occupants' sick building syndrome experience also correlated with the presence of Acanthamoeba in the ventilation system (r=0.361; p=0.01) and those detected on the furniture (r=0.290; p=0.01). Logistic regression showed that there was a five-fold probability of sick building syndrome among occupants when Acanthamoeba was detected in the ventilation system.

  20. Parent's Guide to School Indoor Air Quality. Revised

    Science.gov (United States)

    Healthy Schools Network, Inc., 2012

    2012-01-01

    Air pollution is air pollution, indoors or out. Good indoor air quality (IAQ) contributes to a favorable learning environment for students, protects health, and supports the productivity of school personnel. In schools in poor repair, leaky roofs and crumbling walls have caused additional indoor air quality problems, including contamination with…

  1. Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute

    OpenAIRE

    Espinosa, G.; Golzarri, J.I.; Lopez, K.; Rickards, J.

    2011-01-01

    The results of six months of continuous measurement of the indoor radon concentration levels in the building where the Instituto de Física 3 MV Pelletron particle accelerator is located are presented. This study has three major objectives: (a) to know the actual values of the levels of indoor radon in this installation, where personnel spend many hours and sometimes days; (b) assess the radiological risk from radon inhalation for personnel working permanently in the laboratory, as well as inc...

  2. Identifying Typical Movements Among Indoor Objects

    DEFF Research Database (Denmark)

    Radaelli, Laura; Sabonis, Dovydas; Lu, Hua

    2013-01-01

    With the proliferation of mobile computing, positioning systems are becoming available that enable indoor location-based services. As a result, indoor tracking data is also becoming available. This paper puts focus on one use of such data, namely the identification of typical movement patterns...

  3. Outdoor and indoor dose assessment using environmental thermoluminescence dosimeters (TLDs) in Costa Rica

    International Nuclear Information System (INIS)

    Mora, Patricia

    2003-01-01

    Costa Rica lies at the intersection of the Cocos and Caribbean plates in Central America. It has mountain ranges with many active volcanoes along its territory. Its soils are predominantly of volcanic origin. Natural radiation measurements utilising environmental CaF 2 :Dy thermoluminescence dosimeters were used for the first time in Costa Rica by the Dosimetry Section of the Atomic, Nuclear and Molecular Sciences Research Center of the University of Costa Rica. Seven hundred outdoor measurements were obtained in a 3.5-year period at eight different sites throughout the country. One hundred and seventy-four indoor readings were also collected at four sites for a 2-year period. Population-weighted averages give 82 nGy h -1 for outdoors and 130 nGy h -1 for indoors. The values lie on the upper range of worldwide reported values due to reported soil characteristics rich in uranium and potassium. A preliminary population-weighted value of 0.74 mSv/year for the effective dose is calculated for natural terrestrial gamma radiation in Costa Rica

  4. Vitality of plants to live in the indoor environment

    Science.gov (United States)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live

  5. Indoor wayfinding and navigation

    CERN Document Server

    2015-01-01

    Due to the widespread use of navigation systems for wayfinding and navigation in the outdoors, researchers have devoted their efforts in recent years to designing navigation systems that can be used indoors. This book is a comprehensive guide to designing and building indoor wayfinding and navigation systems. It covers all types of feasible sensors (for example, Wi-Fi, A-GPS), discussing the level of accuracy, the types of map data needed, the data sources, and the techniques for providing routes and directions within structures.

  6. TOWARDS A FAST, LOW-COST INDOOR MAPPING AND POSITIONING SYSTEM FOR CIVIL PROTECTION AND EMERGENCY TEAMS

    Directory of Open Access Journals (Sweden)

    E. Angelats

    2017-11-01

    Full Text Available Civil protection and emergency teams work usually under very risky conditions that endanger their lives. One of the factors contributing to such risks is the lack of knowledge about their physical environment, especially when working indoors. Mapping and location indoor and outdoor technologies exist; for outdoors, very good levels of precision and accuracy may be obtained using offthe- shelf equipment; on the other side, and although good solutions for indoor environments are available, these require some extra pre-deployed infrastructure in the area to navigate, which is unacceptable in the case of emergency teams. It may be said, then, that no mature indoor + outdoor integrated solution providing the appropriate precision and accuracy for the purposes of emergency teams exist. In this paper, the assessment of a set of currently available sensors (IMUs, RGB-D cameras, GNSS receivers and algorithms is presented to show that it is already possible to build such a solution relying on them – providing that appropriate (indoor lightning and texture conditions exist.

  7. Assessment of human body influence on exposure measurements of electric field in indoor enclosures.

    Science.gov (United States)

    de Miguel-Bilbao, Silvia; García, Jorge; Ramos, Victoria; Blas, Juan

    2015-02-01

    Personal exposure meters (PEMs) used for measuring exposure to electromagnetic fields (EMF) are typically used in epidemiological studies. As is well known, these measurement devices cause a perturbation of real EMF exposure levels due to the presence of the human body in the immediate proximity. This paper aims to model the alteration caused by the body shadow effect (BSE) in motion conditions and in indoor enclosures at the Wi-Fi frequency of 2.4 GHz. For this purpose, simulation techniques based on ray-tracing have been carried out, and their results have been verified experimentally. A good agreement exists between simulation and experimental results in terms of electric field (E-field) levels, and taking into account the cumulative distribution function (CDF) of the spatial distribution of amplitude. The Kolmogorov-Smirnov (KS) test provides a P-value greater than 0.05, in fact close to 1. It has been found that the influence of the presence of the human body can be characterized as an angle of shadow that depends on the dimensions of the indoor enclosure. The CDFs show that the E-field levels in indoor conditions follow a lognormal distribution in the absence of the human body and under the influence of BSE. In conclusion, the perturbation caused by BSE in PEMs readings cannot be compensated for by correction factors. Although the mean value is well adjusted, BSE causes changes in CDF that would require improvements in measurement protocols and in the design of measuring devices to subsequently avoid systematic errors. © 2014 Wiley Periodicals, Inc.

  8. Fatigability in basic indoor mobility in nonagenarians

    DEFF Research Database (Denmark)

    Mänty, Minna Regina; Ekmann, Anette; Thinggaard, Mikael

    2012-01-01

    To evaluate the prevalence and associated health factors of indoor mobility-related fatigability in nonagenarians.......To evaluate the prevalence and associated health factors of indoor mobility-related fatigability in nonagenarians....

  9. Indoor Air Quality Science and Technology

    Science.gov (United States)

    Understand indoor air in homes, schools, and offices. Most of us spend much of our time indoors. The air that we breathe in our homes, in schools, and in offices can put us at risk for health problems. Some pollutants can be chemicals, gases, and living or

  10. [Indoor volatile organic compounds: concentrations, sources, variation factors].

    Science.gov (United States)

    Palot, A; Charpin-Kadouch, C; Ercoli, J; Charpin, D

    2008-06-01

    Volatile organic compounds (V.O.C.) are part of urban air pollution and are also generated indoors from cleaning and maintenance products. VOC measurements are, on average, 10 times higher within homes than outside. Results of the national survey led by the Observatoire National de la Qualité de l'Air Intérieur demonstrated that up to 25% of French homes have very high or high concentrations of VOC. Indoor levels depend mainly on indoor sources. Aldehydes are included in many everyday life products. VOC originate from various household decorating and cleaning products. Some products are less detrimental to the environment and health and have special labelling. Indoor VOC levels also depend on the rate of air exchange and on household characteristics such as indoor temperature and humidity, age of the building, presence of smokers, and communication with a garage. The public may participate in maintaining good indoor air quality and the authorities should also improve regulations. VOC are part of everyday air pollution. Their sources and concentrations should be better monitored.

  11. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  12. Indoor radon measurements in Mexico City

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20364, 01000 Mexico, D.F. (Mexico)], E-mail: espinosa@fisica.unam.mx; Golzarri, J.I. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20364, 01000 Mexico, D.F. (Mexico); Bogard, J. [Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831-6480 (United States); Gaso, I. [Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, 11801 Mexico, D.F. (Mexico); Ponciano, G. [Facultad de Medicina, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico, D.F. (Mexico); Mena, M.; Segovia, N. [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico, D.F. (Mexico)

    2008-08-15

    Mexico City is one of the most populated cities in the world with almost 22 million inhabitants, located at an altitude of 2200 m. The old city was founded on an ancient lake and the zone is known by its high seismicity; indoor radon determination is an important public health issue. In this paper the data of indoor radon levels in Mexico City, measured independently by two research groups, both using Nuclear Track Detector systems but different methodologies, are correlated. The measurements were done during similar exposure periods of time, at family houses from the political administrative regions of the city. The results indicate a correlation coefficient between the two sets of data of R=0.886. Most of the differences between the two sets of data are inherent to houses having extreme (very high or very low indoor radon) included in the statistics of each group. The total average indoor radon found in Mexico City considering the two methods was 87Bqm{sup -3}.

  13. Winter-to-winter variations in indoor radon

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.; Kline, S.W.

    1989-01-01

    Indoor radon concentrations in northern Virginia and central Maryland show a strong dependence on weather. Winter tends to be associated with higher than average indoor radon, and summer with lower than average. However, compared to the winter of 1986-1987, the winter of 1987-1988 was warmer and drier. Consequently, winter-to-winter indoor radon decreased by about 25%. This winter-to-winter decrease is unexpectedly large, and simulates winter-to-summer variations that have been reported

  14. Characterization of indoor aerosol temporal variations for the real-time management of indoor air quality

    Science.gov (United States)

    Ciuzas, Darius; Prasauskas, Tadas; Krugly, Edvinas; Sidaraviciute, Ruta; Jurelionis, Andrius; Seduikyte, Lina; Kauneliene, Violeta; Wierzbicka, Aneta; Martuzevicius, Dainius

    2015-10-01

    The study presents the characterization of dynamic patterns of indoor particulate matter (PM) during various pollution episodes for real-time IAQ management. The variation of PM concentrations was assessed for 20 indoor activities, including cooking related sources, other thermal sources, personal care and household products. The pollution episodes were modelled in full-scale test chamber representing a standard usual living room with the forced ventilation of 0.5 h-1. In most of the pollution episodes, the maximum concentration of particles in exhaust air was reached within a few minutes. The most rapid increase in particle concentration was during thermal source episodes such as candle, cigarette, incense stick burning and cooking related sources, while the slowest decay of concentrations was associated with sources, emitting ultrafine particle precursors, such as furniture polisher spraying, floor wet mopping with detergent etc. Placement of the particle sensors in the ventilation exhaust vs. in the centre of the ceiling yielded comparable results for both measured maximum concentrations and temporal variations, indicating that both locations were suitable for the placement of sensors for the management of IAQ. The obtained data provides information that may be utilized considering measurements of aerosol particles as indicators for the real-time management of IAQ.

  15. Cooperative Agreement Funding for Indoor Air Quality

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  16. Comparisons of indoor radon to other radiation hazards

    International Nuclear Information System (INIS)

    Bodansky, D.; Jackson, K.L.; Geraci, J.P.

    1987-01-01

    The significance of radon as a cause of cancer can be put into perspective by a comparison with other causes of cancer. Lung cancer is fatal in about 90% of the cases and therefore in assessing radon exposures it is pertinent to make a comparison in terms of mortality figures. There is a broad range of estimates for the U.S. lung cancer mortality from indoor radon, extending from well below 5,000 to above 20,000 per year. For simplicity in making comparisons, the authors use an intermediate estimate of 10,000 per year, although one needs to bear in mind this number is uncertain. Given approximately 480,000 fatal cancers in the United States per year and 136,000 fatal lung cancers, this estimate corresponds to indoor radon being responsible for 2% of all cancer mortality and 7% of lung cancer mortality. It is estimated that 83% of lung cancers are due to smoking, corresponding to about 113,000 deaths per year. Overall, therefore, smoking is far more important than indoor radon as a cause of lung cancer. Despite the authors' concentration on it, radon is a relatively small contributor in the perspective of cancer as a whole or even of lung cancer alone. It is a more dominant contributor in considering average exposures to ionizing radiation

  17. Photocatalytic surface reactions on indoor wall paint.

    Science.gov (United States)

    Salthammer, T; Fuhrmann, F

    2007-09-15

    The reduction of indoor air pollutants by air cleaning systems has received considerable interest, and a number of techniques are now available. So far, the method of photocatalysis was mainly applied by use of titanium dioxide (TiO2) in flow reactors under UV light of high intensity. Nowadays, indoor wall paints are equipped with modified TiO2 to work as a catalyst under indoor daylight or artificial light. In chamber experiments carried out under indoor related conditions itwas shown thatthe method works for nitrogen dioxide with air exchange and for formaldehyde without air exchange at high concentrations. In further experiments with volatile organic compounds (VOCs), a small effect was found for terpenoids with high kOH rate constants. For other VOCs and carbon monoxide there was no degradation at all or the surface acted as a reversible sink. Secondary emissions from the reaction of paint constituents were observed on exposure to light. From the results it is concluded that recipes of photocatalytic wall paints need to be optimized for better efficiency under indoor conditions.

  18. Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool

    OpenAIRE

    Mančić Marko V.; Živković Dragoljub S.; Milosavljević Peđa M.; Todorović Milena N.

    2014-01-01

    Buildings with indoor swimming pools have a large energy footprint. The source of major energy loss is the swimming pool hall where air humidity is increased by evaporation from the pool water surface. This increases energy consumption for heating and ventilation of the pool hall, fresh water supply loss and heat demand for pool water heating. In this paper, a mathematical model of the swimming pool was made to assess energy demands of an indoor swimming po...

  19. Design Criteria for Achieving Acceptable Indoor Radon Concentration

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization...... in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating...... from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision...

  20. Improving indoor air quality and thermal comfort in office building by using combination filters

    Science.gov (United States)

    Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.

    2017-09-01

    Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.

  1. Publications and Resources About Indoor airPLUS

    Science.gov (United States)

    Presented are useful materials to help you build homes that meet Indoor airPLUS specifications and to promote Indoor airPLUS qualified homes. These materials are FREE of charge and are available in PDF.

  2. Federal Interagency Committee on Indoor Air Quality

    Science.gov (United States)

    The Federal Interagency Committee on Indoor Air Quality (CIAQ), which meets three times a year, was established by Congress to coordinate the activities of the Federal Government on issues relating to Indoor Air Quality.

  3. Indoor radon progeny aerosol size measurements in urban, suburban, and rural regions

    International Nuclear Information System (INIS)

    Tu, K.W.; Knutson, E.O.; George, A.C.

    1991-01-01

    By using direct and indirect methods, the authors conducted size distribution measurements of radon progeny particles in a variety of indoor environments in urban, suburban, and rural areas. The radon progeny particle size distribution owing to indoor activities has two definable source categories: (1) gas combustion from stoves and kerosene heaters - particles were found to be smaller than 0.1 μm in diameter, mostly in the range 0.02-0.08 μm; and (2) cigarette smoking and food frying - particles were found to be larger, in the size range 0.1-0.2 μm. The radon progeny particle size distribution, without significant indoor activities, such as cooking, was found to be larger in rural areas than in urban or suburban areas. The modal diameters of the size spectra in the rural areas were two to three times larger than those in urban or suburban areas, around 0.3-0.4 bs. 0.1-0.2 μm. Results obtained by applying the attachment theory to the measured number-weighted size spectra from an electrical aerosol size analyzer support this finding. These results, if confirmed by more extensive studies, will be useful for the assessment of the risk from the inhalation of radon progeny in various indoor environments

  4. Finding dense locations in indoor tracking data

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2014-01-01

    for semi-constrained indoor movement, and then uses this to map raw tracking records into mapping records representing object entry and exit times in particular locations. Then, an efficient indexing structure, the Dense Location Time Index (DLT-Index) is proposed for indexing the time intervals...... of the mapping table, along with associated construction, query processing, and pruning techniques. The DLT-Index supports very efficient aggregate point queries, interval queries, and dense location queries. A comprehensive experimental study with real data shows that the proposed techniques can efficiently......Finding the dense locations in large indoor spaces is very useful for getting overloaded locations, security, crowd management, indoor navigation, and guidance. Indoor tracking data can be very large and are not readily available for finding dense locations. This paper presents a graph-based model...

  5. Impacts Of Passive Removal Materials On Indoor Air Quality

    DEFF Research Database (Denmark)

    Darling, Erin; Cros, Clement; Wargocki, Pawel

    2011-01-01

    Indoor air quality (IAQ) was determined in the presence of eight combinations of building materials with and without ozone. Air samples were collected in twin 30 m3 chambers to assess the C5 to C10 aldehyde content of the air while a panel of 18 to 23 human subjects assessed air quality using...... a continuous acceptability scale. Materials were either new carpet that was aired out for three weeks, clay plaster applied to gypsum wallboard that was aired out for up to one month, both materials, or neither. Perceived Air Quality (PAQ) assessed by the panel was most acceptable and concentrations...

  6. Indoor randon concentration. Temperature and wind effects; Concentrazione di radon indoor. Effetto del vento e della temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, L.; Benigni, S. [Milan Univ., Milan (Italy). Ist. di Fisica Generale Applicata

    2000-12-01

    The present study analyses and discusses the behaviour of the indoor radon concentration in a research house. Hourly measurements were carried out in the basement of the house from November 1998 up to June 1999. In many sequences of days radon concentration in the room under analysis shows strong variation all day long with accumulation in the evening and overnight and decrease in the morning and in the afternoon. Measurements of wind velocity, indoor and outdoor temperatures and outdoor-indoor pressure difference were performed and their trend is compared with the observed radon concentration. The exhalation of radon from walls, floor and ceiling and the pressure difference driven exhalation from the soil are discussed, particularly the relation with the temperature differences. The air exchange rates between the house and the outdoor air are studied. [Italian] Si analizza e si discute il comportamento della concentrazione di radon indoor nel seminterrato di una casa di ricerca. Misure orarie sono state effettuate da novembre 1998 a giugno 1999. In molte sequenze di giorni la concentrazione del radon nel locale in analisi presenta forti variazioni nel corso della giornata con un accumulo notturno e decrescita nelle ore diurne. Sono state eseguite misure della velocita' del vento, delle temperature outdoor e indoor e della differenza di pressione outdoor-indoor e il loro andamento e' stato confrontato con quello della concentrazione del radon. Vengono discusse l'esalazione del radon dalle pareti, dal pavimento e dal soffitto e l'esalazione pressure difference driven dal suolo. Il rateo dei ricambi d'aria tra il locale e l'aria outdoor e' studiato.

  7. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  8. Indoor NO{sub 2} levels in homes with different sources of air pollution - traffic, gas-use, smoking

    Energy Technology Data Exchange (ETDEWEB)

    Rudnai, P.; Farkas, I.; Bacskai, J.; Sarkany, E. [Bela Johan National Inst. of Hygiene, Budapest (Hungary); Somogyi, J. [Public Health Inst. of County Gyor-Moson-Sopron, Gyor (Hungary)

    1993-12-31

    Outdoor and indoor levels of NO{sub 2} in and around the homes of 300 children living in different parts of two Hungarian towns, Gyor and Sopron, were measured. Possible sources of NO{sub 2} pollution were assessed by questionnaires. NO{sub 2} levels in homes without any further known sources (like gas use for cooking and/or heating and smoking) varied according to the outdoor levels mainly depending on traffic density. Gas heaters had the strongest influence on the indoor NO{sub 2} levels measured in the children`s bedrooms while gas use for cooking and smoking proved to be the second and third most important source of indoor NO{sub 2} pollution. Different outdoor and indoor NO{sub 2} sources should be taken into account when planning the heating and ventilation systems of new buildings. (author)

  9. Health and economic benefits of building ventilation interventions for reducing indoor PM2.5 exposure from both indoor and outdoor origins in urban Beijing, China.

    Science.gov (United States)

    Yuan, Ye; Luo, Zhiwen; Liu, Jing; Wang, Yaowu; Lin, Yaoyu

    2018-06-01

    China is confronted with serious PM 2.5 pollution, especially in the capital city of Beijing. Exposure to PM 2.5 could lead to various negative health impacts including premature mortality. As people spend most of their time indoors, the indoor exposure to PM 2.5 from both indoor and outdoor origins constitutes the majority of personal exposure to PM 2.5 pollution. Different building interventions have been introduced to mitigate indoor PM 2.5 exposure, but always at the cost of energy expenditure. In this study, the health and economic benefits of different ventilation intervention strategies for reducing indoor PM 2.5 exposure are modeled using a representative urban residence in Beijing, with consideration of different indoor PM 2.5 emission strengths and outdoor pollution. Our modeling results show that the increase of envelope air-tightness can achieve significant economic benefits when indoor PM 2.5 emissions are absent; however, if an indoor PM 2.5 source is present, the benefits only increase slightly in mechanically ventilated buildings, but may show negative benefit without mechanical ventilation. Installing mechanical ventilation in Beijing can achieve annual economic benefits ranging from 200yuan/capita to 800yuan/capita if indoor PM 2.5 sources exist. If there is no indoor emission, the annual benefits above 200yuan/capita can be achieved only when the PM 2.5 filtration efficiency is no urban Beijing will increase the indoor PM 2.5 exposure and result in excess costs to the residents. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Indoor Air Quality: Maryland Public Schools.

    Science.gov (United States)

    Maryland State Dept. of Education, College Park. Office of Administration and Finance.

    Less than adequate indoor air quality in schools can lead to a higher risk of health problems, an increase in student and teacher absenteeism, diminished learning, and even hazardous conditions. An indoor air quality program that addresses the planning, design, maintenance, and operation of public school buildings should be implemented at the…

  11. About the Subdivision of Indoor Spaces in Indoorgml

    Science.gov (United States)

    Diakité, A. A.; Zlatanova, S.; Li, K.-J.

    2017-10-01

    Boosted by the dynamic urbanization of cities, indoor environments are getting more and more complex in order to be able to host people properly. While most of our time is spent inside buildings, the need of GIS tools to assist our daily activities that can become tedious, such as indoor navigation or facility management, became more and more urgent. In that perspective, the IndoorGML standard is aiming to address the gaps left by other standards regarding the spatial modelling for indoor navigation. It includes several concepts such as the organization of the spaces into cells along with their network representation and the possibility to represent multiple connected layers. However, being at its first stage, several concepts of the standard could be improved. One of these is the cell subspacing that is not enough discussed in the current version of the standard. In this paper, we explore all the aspects involved in the subdivision process, from the identification of the navigable and non-navigable space cells to the generation of a navigation graph. We propose several criteria on which the indoor sub-spacing can rely to be automatically performed and and illustrate them on a 3D indoor model.

  12. Soil as a source of indoor 220Rn

    International Nuclear Information System (INIS)

    Li, Y.; Schery, S.D.; Turk, B.

    1992-01-01

    Two suggestions for sources of indoor 220Rn (thoron) have appeared in the literature: (1) building materials and outside air, and (2) soil beneath the house. Due to the difficulty of 220Rn measurement and limited data, both suggestions lack sufficient supporting evidence. We have investigated sources of indoor 220Rn in seven occupied houses in northern New Mexico, U.S. A two-filter system was used to measure indoor 220Rn levels continuously, and 220Rn progeny were measured with single filters and specialized alpha-track detectors. The amount of 220Rn entry from soil was curtailed by cutting off soil gas flow to the indoor air with subfloor depressurization mitigation systems. Four of the houses showed significant reductions in 220Rn with mitigation systems on. The average effect for these houses was to reduce indoor 220Rn levels by 70%. The other three houses had no clear reductions but in one of these houses, the mitigation system was not effective for stopping soil gas flow. Our results provide some of the most clear evidence to date supporting soil as an important source of indoor 220Rn

  13. Hourly indoor radon measurements in a research house.

    Science.gov (United States)

    Sesana, Lucia; Begnini, Stefania

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Prealps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of (222)Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence.

  14. Hourly indoor radon measurements in a research house

    International Nuclear Information System (INIS)

    Sesana, L.; Begnini, S.

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Pre-alps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of 222 Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence. (authors)

  15. Sustainable indoor lighting

    CERN Document Server

    Mercatelli, Luca; Farini, Alessandro

    2015-01-01

    Encompassing a thorough survey of the lighting techniques applied to internal illumination characterized by high efficiency, optimized color and architectural integration, a consolidated summary of the latest scientific, technical and architectural research is presented in order to give the reader an overview of the different themes with their interactions and mutual effects.   This book describes light principles, methodologies and realisations for indoor illumination at low consumption. Power efficiency, color characteristics and architectural aspects are analyzed in terms of their  practical application, with the interactions between scientific, technological and architectural features considered in order to supply a complete overview, which can be read both at technical level and at user level. Introducing photometric and radiometric quantities and laws, the book first discusses tests and measurements assessing lighting and color characteristics before examining in detail artificial light sources with p...

  16. Energy-efficient Building in Greenland: Investigation of the Energy Consumption and Indoor Climate

    DEFF Research Database (Denmark)

    Luc, Katarzyna Marta; Kotol, Martin; Lading, Tove

    2016-01-01

    Recently, a brand new single family home was built in Sisimiut, Greenland. The building was constructed as a wooden house typical for Greenland. However, some non-traditional measures were implemented in order to reduce the energy consumption and improve indoor air quality. Assessment...... was installed in the house. It enables the evaluation of the indoor air quality, as well as building's energy performance. The aim of this investigation was to evaluate the performance of the newly constructed house by and compare it with the performance of identical house built in a traditional way by using...... a computer model. The data obtained from the measurements in the new house were used to verify the model. Significant energy savings and improvements of indoor air quality were found in the new house when compared to the traditional one. Moreover, all the extra measures have a feasible payback time despite...

  17. Indoor air quality in hospitality venues before and after implementation of a clean indoor air law--Western New York, 2003.

    Science.gov (United States)

    2004-11-12

    Secondhand smoke (SHS) contains more than 50 carcinogens. SHS exposure is responsible for an estimated 3,000 lung cancer deaths and more than 35,000 coronary heart disease deaths among never smokers in the United States each year, and for lower respiratory infections, asthma, sudden infant death syndrome, and chronic ear infections among children. Even short-term exposures to SHS, such as those that might be experienced by a patron in a restaurant or bar that allows smoking, can increase the risk of experiencing an acute cardiovascular event. Although population-based data indicate declining SHS exposure in the United States over time, SHS exposure remains a common but preventable public health hazard. Policies requiring smoke-free environments are the most effective method of reducing SHS exposure. Effective July 24, 2003, New York implemented a comprehensive state law requiring almost all indoor workplaces and public places (e.g., restaurants, bars, and other hospitality venues) to be smoke-free. This report describes an assessment of changes in indoor air quality that occurred in 20 hospitality venues in western New York where smoking or indirect SHS exposure from an adjoining room was observed at baseline. The findings indicate that, on average, levels of respirable suspended particles (RSPs), an accepted marker for SHS levels, decreased 84% in these venues after the law took effect. Comprehensive clean indoor air policies can rapidly and effectively reduce SHS exposure in hospitality venues.

  18. Seasonal variations of indoor microbial exposures and their relation to temperature, relative humidity, and air exchange rate.

    Science.gov (United States)

    Frankel, Mika; Bekö, Gabriel; Timm, Michael; Gustavsen, Sine; Hansen, Erik Wind; Madsen, Anne Mette

    2012-12-01

    Indoor microbial exposure has been related to adverse pulmonary health effects. Exposure assessment is not standardized, and various factors may affect the measured exposure. The aim of this study was to investigate the seasonal variation of selected microbial exposures and their associations with temperature, relative humidity, and air exchange rates in Danish homes. Airborne inhalable dust was sampled in five Danish homes throughout the four seasons of 1 year (indoors, n = 127; outdoors, n = 37). Measurements included culturable fungi and bacteria, endotoxin, N-acetyl-beta-d-glucosaminidase, total inflammatory potential, particles (0.75 to 15 μm), temperature, relative humidity, and air exchange rates. Significant seasonal variation was found for all indoor microbial exposures, excluding endotoxin. Indoor fungi peaked in summer (median, 235 CFU/m(3)) and were lowest in winter (median, 26 CFU/m(3)). Indoor bacteria peaked in spring (median, 2,165 CFU/m(3)) and were lowest in summer (median, 240 CFU/m(3)). Concentrations of fungi were predominately higher outdoors than indoors, whereas bacteria, endotoxin, and inhalable dust concentrations were highest indoors. Bacteria and endotoxin correlated with the mass of inhalable dust and number of particles. Temperature and air exchange rates were positively associated with fungi and N-acetyl-beta-d-glucosaminidase and negatively with bacteria and the total inflammatory potential. Although temperature, relative humidity, and air exchange rates were significantly associated with several indoor microbial exposures, they could not fully explain the observed seasonal variations when tested in a mixed statistical model. In conclusion, the season significantly affects indoor microbial exposures, which are influenced by temperature, relative humidity, and air exchange rates.

  19. Nitric oxide in exhaled and aspirated nasal air as an objective measure of human response to indoor air pollution

    DEFF Research Database (Denmark)

    Kolarik, Barbara; Lagercrantz, L.; Sundell, Jan

    2009-01-01

    The concentration of nitric oxide (NO) in exhaled and aspirated nasal air was used to objectively assess human response to indoor air pollutants in a climate chamber exposure experiment. The concentration of NO was measured before exposure, after 2, and 4.5 h of exposure, using a chemiluminescence...... by the exposures. The results may indicate an association between polluted indoor air and subclinical inflammation.Measurement of nitric oxide in exhaled air is a possible objective marker of subclinical inflammation in healthy adults....... NO analyzer. Sixteen healthy female subjects were exposed to two indoor air pollutants and to a clean reference condition for 4.5 h. Subjective assessments of the environment were obtained by questionnaires. After exposure (4.5 h) to the two polluted conditions a small increase in NO concentration in exhaled...

  20. An Evaluation of Antifungal Agents for the Treatment of Fungal Contamination in Indoor Air Environments

    Directory of Open Access Journals (Sweden)

    Senthaamarai Rogawansamy

    2015-06-01

    Full Text Available Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®, 70% ethanol, vinegar (4.0%-4.2% acetic acid, and a plant-derived compound (tea tree (Melaleuca alternifolia oil tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum, which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%–4.2% acetic acid was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to

  1. An evaluation of antifungal agents for the treatment of fungal contamination in indoor air environments.

    Science.gov (United States)

    Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino

    2015-06-02

    Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®), 70% ethanol, vinegar (4.0%-4.2% acetic acid), and a plant-derived compound (tea tree (Melaleuca alternifolia) oil) tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum), which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%-4.2% acetic acid) was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to inhibit the growth

  2. Towards an integrative approach of improving indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Bluyssen, Philomena M. [TNO Built Environment and Geosciences, P.O. Box 49, 2600 AA Delft (Netherlands)

    2009-09-15

    There seems to be a discrepancy between current Indoor Air Quality standards and end-users wishes and demands. Indoor air quality can be approached from three points of view: the human, the indoor air of the space and the sources contributing to indoor air pollution. Standards currently in use mainly address the indoor air of the space. ''Other or additional'' recommendations and guidelines are required to improve indoor air quality. Even though we do not fully understand the mechanisms behind the physical, chemical, physiological and psychological processes, it is still possible to identify the different ways to be taken regulatory, politically-socially (awareness), technically (process and product) and scientifically. Besides the fact that there is an urgent need to involve medicine and neuro-psychology in research to investigate the mechanisms behind dose-response, health effects and interactions between and with the other factors and parameters of the indoor environment and the human body and mind, a holistic approach is required including the sources, the air and last but not least the human beings (occupants) themselves. This paper mainly focuses on the European situation. (author)

  3. Dynamic behavior of semivolatile organic compounds in indoor air

    Energy Technology Data Exchange (ETDEWEB)

    Loy, Michael David Van [Univ. of California, Berkeley, CA (United States)

    1998-12-09

    Exposures to a wide range of air pollutants are often dominated by those occurring in buildings because of three factors: 1) most people spend a large fraction of their time indoors, 2) many pollutants have strong indoor sources, and 3) the dilution volume in buildings is generally several orders of magnitude smaller than that of an urban airshed. Semivolatile organic compounds (SVOCS) are emitted by numerous indoor sources, including tobacco combustion, cooking, carpets, paints, resins, and glues, so indoor gasphase concentrations of these compounds are likely to be elevated relative to ambient levels. The rates of uptake and release of reversibly sorbing SVOCS by indoor materials directly affect both peak concentrations and persistence of the pollutants indoors after source elimination. Thus, accurate predictions of SVOC dynamics in indoor air require an understanding of contaminant sorption on surface materials such as carpet and wallboard. The dynamic behaviors of gas-phase nicotine and phenanthrene were investigated in a 20 ms stainless steel chamber containing carpet and painted wallboard. Each compound was studied independently, first in the empty chamber, then with each sorbent individually, and finally with both sorbents in the chamber.

  4. Hypercoagulability in patients undergoing coronary artery bypass grafting: prevalence, patient characteristics and postoperative outcome

    DEFF Research Database (Denmark)

    Rafiq, Sulman; Johansson, Per Ingemar; Ostrowski, Sisse Rye

    2012-01-01

    OBJECTIVESTo investigate the prevalence of preoperative hypercoagulability assessed by thromboelastography (TEG), to identify patient characteristics associated with hypercoagulability and to explore whether hypercoagulability is associated with a greater risk for myocardial infarction (MI), stroke...

  5. Biosynthesized silver nanoparticles to control fungal infections in indoor environments

    Science.gov (United States)

    Deyá, Cecilia; Bellotti, Natalia

    2017-06-01

    Fungi grow especially in dark and moist areas, deteriorating the indoor environment and causing infections that particularly affect immunosuppressed individuals. Antimicrobial coatings have as principal objective to prevent biofilm formation and infections by incorporation of bioactive additives. In this sense, metallic nanoparticles, such as silver, have proven to be active against different microorganisms specially bacteria. Biosynthesized method is a promising environmentally friendly option to obtain nanoparticles. The aim of this research was assess the employment of plants extracts of Aloysia triphylla (cedrón), Laurelia sempervirens (laurel) and Ruta chalepensis (ruda) to obtain silver nanoparticles to be used as an antimicrobial additive to a waterborne coating formulation. The products obtained were assessed against fungal isolates from biodeteriorated indoor coatings. The fungi were identified by conventional and molecular techniques as Chaetomium globosum and Alternaria alternate. The results revealed that the coating with silver nanoparticles obtained with L. sempervirens extract at 60 °C with a size of 9.8 nm was the most efficient against fungal biofilm development.

  6. Improving Wi-Fi Based Indoor Positioning Using Bluetooth Add-Ons

    DEFF Research Database (Denmark)

    Baniukevic, Artur; Sabonis, Dovydas; Jensen, Christian S.

    2011-01-01

    enabling indoor LBSs. Existing indoor positioning services typically use a single technology such as Wi-Fi, RFID or Bluetooth. Wi-Fi based indoor positioning is relatively easy to deploy, but does often not offer good positioning accuracy. In contrast, the use of RFID or Bluetooth for positioning requires...... considerable investments in equipment in order to ensure good positioning accuracy. Motivated by these observations, we propose a hybrid approach to indoor positioning. In particular, we introduce Bluetooth hotspots into an indoor space with an existing Wi-Fi infrastructure such that better positioning...

  7. Accurate Simulation of 802.11 Indoor Links: A "Bursty" Channel Model Based on Real Measurements

    Directory of Open Access Journals (Sweden)

    Agüero Ramón

    2010-01-01

    Full Text Available We propose a novel channel model to be used for simulating indoor wireless propagation environments. An extensive measurement campaign was carried out to assess the performance of different transport protocols over 802.11 links. This enabled us to better adjust our approach, which is based on an autoregressive filter. One of the main advantages of this proposal lies in its ability to reflect the "bursty" behavior which characterizes indoor wireless scenarios, having a great impact on the behavior of upper layer protocols. We compare this channel model, integrated within the Network Simulator (ns-2 platform, with other traditional approaches, showing that it is able to better reflect the real behavior which was empirically assessed.

  8. Exposure to unusually high indoor radon levels

    International Nuclear Information System (INIS)

    Rasheed, F.N.

    1993-01-01

    Unusually high indoor radon concentrations were reported in a small village in western Tyrol, Austria. The authors have measured the seasonal course of indoor radon concentrations in 390 houses of this village. 71% of houses in winter and 33% in summer, showed radon values on the ground floor above the Austrian action level of 400 Bq/cm 3 . This proportion results in an unusually high indoor radon exposure of the population. The radon source was an 8,700-year-old rock slide of granite gneiss, the largest of the alpine crystalline rocks. It has a strong emanating power because its rocks are heavily fractured and show a slightly increased uranium content. Previous reports show increased lung cancer mortality, myeloid leukemia, kidney cancer, melanoma, and prostate cancer resulting from indoor radon exposure. However, many studies fail to provide accurate information on indoor radon concentrations, classifying them merely as low, intermediate, and high, or they record only minor increases in indoor radon concentrations. Mortality data for 1970-91 were used to calculate age and sex standardized mortality rates (SMR) for 51 sites of carcinoma. The total population of Tyrol were controls. A significantly higher risk was recorded for lung cancer. The high SMR for lung cancer in female subjects is especially striking. Because the numbers were low for the other cancer sites, these were combined in one group to calculate the SMR. No significant increase in SMR was found for this group

  9. An Innovative Gateway for Indoor Positioning

    Directory of Open Access Journals (Sweden)

    Marias Giannis F

    2006-01-01

    Full Text Available Enabling the pervasive paradigm requires the incorporation of location information. Retrieving location data has been a field of ongoing research for both the outdoor and indoor wireless systems. The results in the cellular scenario are already mature and location architectures have been standardized. Recent research is ongoing for indoor-positioning mechanisms, resulting in implementations that vary. A platform that enables the deployment of location-based services in heterogeneous indoor and WLAN-based communication systems will address difficulties in cooperating with different positioning systems. For that purpose, we have designed a novel entity, called Gateway WLAN Location Center (GWLC, which hides the heterogeneous functions of the indoor positioning architectures, incorporating a unified framework for retrieving location data of users and objects. The GWLC platform has been designed to meet objectives such as modularity, scalability, as well as portability, and to facilitate open interfaces. In this contribution, we elaborate on the design principles and the functionality of GWLC. We also provide performance results, obtained through real experiments.

  10. Indoor air quality in low-energy houses in the Netherlands: Does mechanical ventilation provide a healthy indoor environment?

    NARCIS (Netherlands)

    Balvers, J.R.; Boxem, G.; Wit, de M.H.; Strøm-Tejsen, P; Olesen, B.W.; Wargocki, P; Zukowska, D; Toftum, J

    2008-01-01

    Increasing environmental awareness has led to new, energy-efficient building standards such as the German Passivhaus-standard. This study was designed to investigate the indoor air quality (IAQ) of four different Dutch low-energy houses built according to this standard. Air flow, indoor air

  11. Monocular Vision SLAM for Indoor Aerial Vehicles

    Directory of Open Access Journals (Sweden)

    Koray Çelik

    2013-01-01

    Full Text Available This paper presents a novel indoor navigation and ranging strategy via monocular camera. By exploiting the architectural orthogonality of the indoor environments, we introduce a new method to estimate range and vehicle states from a monocular camera for vision-based SLAM. The navigation strategy assumes an indoor or indoor-like manmade environment whose layout is previously unknown, GPS-denied, representable via energy based feature points, and straight architectural lines. We experimentally validate the proposed algorithms on a fully self-contained microaerial vehicle (MAV with sophisticated on-board image processing and SLAM capabilities. Building and enabling such a small aerial vehicle to fly in tight corridors is a significant technological challenge, especially in the absence of GPS signals and with limited sensing options. Experimental results show that the system is only limited by the capabilities of the camera and environmental entropy.

  12. Normal and seasonally amplified indoor radon levels

    International Nuclear Information System (INIS)

    Gammage, R.B.; Dudney, C.S.; Wilson, D.L.; King, D.

    1995-01-01

    Winter and summer indoor radon measurements are reported for 121 houses in Freehold, New Jersey. When presented as winter:summer ratios of indoor radon, the data closely approximate a lognormal distribution. The geometric mean is 1.49. Freehold is located on the fairly flat coastal plain. The winter:summer ratios are believed to represent the norm for regions of the U.S. with cold winters and hot summers. The Freehold data set can be compared to corresponding data sets from other locations to suggest seasonal perturbations of indoor radon arising from unusual causes

  13. Antimicrobial Treatments of Indoor Mold and Bacteria

    Science.gov (United States)

    Biological contaminants especially mold in buildings are known to act as sources of indoor air pollution, discomfort, asthma and pulmonary disease to building occupants. Sick buildings are evidence of extremely problematic indoor air quality (IAQ), often resulting from unacceptab...

  14. Very volatile organic compounds: An understudied class of indoor air pollutants: Keynote: Indoor Air 2014

    OpenAIRE

    Salthammer, T.

    2016-01-01

    Very volatile organic compounds (VVOCs), as categorized by the WHO, are an important subgroup of indoor pollutants and cover a wide spectrum of chemical substances. Some VVOCs are components of products commonly used indoors, some result from chemical reactions and some are reactive precursors of secondary products. Nevertheless, there is still no clear and internationally accepted definition of VVOCs. Current approaches are based on the boiling point, and the saturation vapor pressure or ref...

  15. Indoor Exposure and Adverse Birth Outcomes Related to Fetal Growth, Miscarriage and Prematurity—A Systematic Review

    Directory of Open Access Journals (Sweden)

    Evridiki Patelarou

    2014-06-01

    Full Text Available The purpose of this review was to summarize existing epidemiological evidence of the association between quantitative estimates of indoor air pollution and all-day personal exposure with adverse birth outcomes including fetal growth, prematurity and miscarriage. We carried out a systematic literature search of MEDLINE and EMBASE databases with the aim of summarizing and evaluating the results of peer-reviewed epidemiological studies undertaken in “westernized” countries that have assessed indoor air pollution and all-day personal exposure with specific quantitative methods. This comprehensive literature search identified 16 independent studies which were deemed relevant for further review and two additional studies were added through searching the reference lists of all included studies. Two reviewers independently and critically appraised all eligible articles using the Critical Appraisal Skills Programme (CASP tool. Of the 18 selected studies, 14 adopted a prospective cohort design, three were case-controls and one was a retrospective cohort study. In terms of pollutants of interest, seven studies assessed exposure to electro-magnetic fields, four studies assessed exposure to polycyclic aromatic hydrocarbons, four studies assessed PM2.5 exposure and three studies assessed benzene, phthalates and noise exposure respectively. Furthermore, 12 studies examined infant growth as the main birth outcome of interest, six examined spontaneous abortion and three studies assessed gestational age at birth and preterm delivery. This survey demonstrates that there is insufficient research on the possible association of indoor exposure and early life effects and that further research is needed.

  16. Socio-economic costs of indoor air pollution: A tentative estimation for some pollutants of health interest in France.

    Science.gov (United States)

    Boulanger, Guillaume; Bayeux, Thomas; Mandin, Corinne; Kirchner, Séverine; Vergriette, Benoit; Pernelet-Joly, Valérie; Kopp, Pierre

    2017-07-01

    An evaluation of the socio-economic costs of indoor air pollution can facilitate the development of appropriate public policies. For the first time in France, such an evaluation was conducted for six selected pollutants: benzene, trichloroethylene, radon, carbon monoxide, particles (PM 2.5 fraction), and environmental tobacco smoke (ETS). The health impacts of indoor exposure were either already available in published works or were calculated. For these calculations, two approaches were followed depending on the available data: the first followed the principles of quantitative health risk assessment, and the second was based on concepts and methods related to the health impact assessment. For both approaches, toxicological data and indoor concentrations related to each target pollutant were used. External costs resulting from mortality, morbidity (life quality loss) and production losses attributable to these health impacts were assessed. In addition, the monetary costs for the public were determined. Indoor pollution associated with the selected pollutants was estimated to have cost approximately €20 billion in France in 2004. Particles contributed the most to the total cost (75%), followed by radon. Premature death and the costs of the quality of life loss accounted for approximately 90% of the total cost. Despite the use of different methods and data, similar evaluations previously conducted in other countries yielded figures within the same order of magnitude. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Towards the Application of Fuzzy Logic for Developing a Novel Indoor Air Quality Index (FIAQI).

    Science.gov (United States)

    Javid, Allahbakhsh; Hamedian, Amir Abbas; Gharibi, Hamed; Sowlat, Mohammad Hossein

    2016-02-01

    In the past few decades, Indoor Air Pollution (IAP) has become a primary concern to the point. It is increasingly believed to be of equal or greater importance to human health compared to ambient air. However, due to the lack of comprehensive indices for the integrated assessment of indoor air quality (IAQ), we aimed to develop a novel, Fuzzy-Based Indoor Air Quality Index (FIAQI) to bridge the existing gap in this area. We based our index on fuzzy logic, which enables us to overcome the limitations of traditional methods applied to develop environmental quality indices. Fifteen parameters, including the criteria air pollutants, volatile organic compounds, and bioaerosols were included in the FIAQI due mainly to their significant health effects. Weighting factors were assigned to the parameters based on the medical evidence available in the literature on their health effects. The final FIAQI consisted of 108 rules. In order to demonstrate the performance of the index, data were intentionally generated to cover a variety of quality levels. In addition, a sensitivity analysis was conducted to assess the validity of the index. The FIAQI tends to be a comprehensive tool to classify IAQ and produce accurate results. It seems useful and reliable to be considered by authorities to assess IAQ environments.

  18. Education of indoor enviromental engineering technology

    Czech Academy of Sciences Publication Activity Database

    Kic, P.; Zajíček, Milan

    2011-01-01

    Roč. 9, Spec. 1 (2011), s. 83-90 ISSN 1406-894X. [Biosystems Engineering 2011. Tartu, 12.05.2011-13.05.2011] Institutional research plan: CEZ:AV0Z10750506 Keywords : Biosystems engineering * indoor environment * study * programs Subject RIV: AM - Education http://library.utia.cas.cz/separaty/2011/VS/zajicek-education of indoor enviromental engineering technology.pdf

  19. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.; Nazaroff, W.W.; Wells, J.R.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  20. Allegheny County Clean Indoor Air Act Exemptions

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — List and location of all the businesses and social clubs who have received an exemption from the Pennsylvania Clean Indoor Air Act. “The Clean Indoor Air Act, Act...

  1. Experimental evaluation of indoor magnetic distortion effects on gait analysis performed with wearable inertial sensors

    International Nuclear Information System (INIS)

    Palermo, E; Patanè, F; Cappa, P; Rossi, S

    2014-01-01

    Magnetic inertial measurement unit systems (MIMU) offer the potential to perform joint kinematics evaluation as an alternative to optoelectronic systems (OS). Several studies have reported the effect of indoor magnetic field disturbances on the MIMU's heading output, even though the overall effect on the evaluation of lower limb joint kinematics is not yet fully explored. The aim of the study is to assess the influence of indoor magnetic field distortion on gait analysis trials conducted with a commercial MIMU system. A healthy adult performed gait analysis sessions both indoors and outdoors. Data collected indoors were post-processed with and without a heading correction methodology performed with OS at the start of the gait trial. The performance of the MIMU system is characterized in terms of indices, based on the mean value of lower limb joint angles and the associated ROM, quantifying the system repeatability. We find that the effects of magnetic field distortion, such as the one we experienced in our lab, were limited to the transverse plane of each joint and to the frontal plane of the ankle. Sagittal plane values, instead, showed sufficient repeatability moving from outdoors to indoors. Our findings provide indications to clinicians on MIMU performance in the measurement of lower limb kinematics. (paper)

  2. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  3. Indoor Environmental Factors and Occurrence of Lung Function Decline in Adult Residents in Summer in Southwest China.

    Science.gov (United States)

    Jie, Yu; Kebin, Li; Yin, Tang; Jie, Xu

    2016-11-01

    There is conflicting reports on the respiratory health effects of indoor risk factor exposure. The aim of this study was to assess the association of indoor environmental factors to pulmonary function in an adult population in Zunyi City of Southwest China. Between July and Sep 2012, we conducted a cross-sectional survey of people aged ≥18 yr in 11 inner-city areas of Zunyi. Data on asthma and asthma-related symptoms and selected home environmental factors were assessed by questionnaire. Lung function measurements, including FVC, FEV 1 , FEV 1 /FVC and PEFR, were assessed and compared. Exposure to indoor and outdoor PM 2.5 was monitored by measurement of PM 2.5 emission relative concentration. Cooking oil fumes, environmental tobacco smoke (ETS) and coal fuel use were associated with impaired lung function among adults in summer season ( P oil fumes, pest in kitchen, mosquito repellent, fluffy blanket, pets, visible mold in bedroom and ETS (active and passive smoking) tended to exhibit greater decreases in FVC, FEV 1 and PEFR values compared with their non-exposed counterparts ( P kitchen, sleeping area and outdoor were 486.0cpm, 463.0cpm and 459.0cpm, respectively. PM 2.5 relative concentration in indoor kitchen and sleeping area were significant higher than outdoor ( P kitchen, sleeping area risk factors and ETS exposure and a reduction in lung function in summer was revealed in Zunyi.

  4. ABOUT THE SUBDIVISION OF INDOOR SPACES IN INDOORGML

    Directory of Open Access Journals (Sweden)

    A. A. Diakité

    2017-10-01

    Full Text Available Boosted by the dynamic urbanization of cities, indoor environments are getting more and more complex in order to be able to host people properly. While most of our time is spent inside buildings, the need of GIS tools to assist our daily activities that can become tedious, such as indoor navigation or facility management, became more and more urgent. In that perspective, the IndoorGML standard is aiming to address the gaps left by other standards regarding the spatial modelling for indoor navigation. It includes several concepts such as the organization of the spaces into cells along with their network representation and the possibility to represent multiple connected layers. However, being at its first stage, several concepts of the standard could be improved. One of these is the cell subspacing that is not enough discussed in the current version of the standard. In this paper, we explore all the aspects involved in the subdivision process, from the identification of the navigable and non-navigable space cells to the generation of a navigation graph. We propose several criteria on which the indoor sub-spacing can rely to be automatically performed and and illustrate them on a 3D indoor model.

  5. Percieved control over indoor climate and its impact on Dutch office workers

    NARCIS (Netherlands)

    Boerstra, A.C.; Loomans, M.G.L.C.; Hensen, J.L.M.; Loomans, M.G.L.C.; Kulve, te M.

    2015-01-01

    A field study was conducted in nine modern office buildings in the Netherlands. The study focused on perceived control over indoor climate and its impact on satisfaction of building occupants, the incidence of building related (SBS) symptoms and self-assessed performance. The study involved a

  6. A Study on Public Opinion Poll and Policy on Indoor Air Pollution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.S.; Lee, H.S.; Kong, S.Y.; Ku, H.J. [Korea Environment Institute, Seoul (Korea)

    2001-12-01

    The purpose of this study is to review previous studies on indoor air pollution and to propose national strategies and policy measures for protecting public health from indoor air pollution based on the results of public survey research. Indoor air has the potential to be polluted by hazardous materials that might lead to serious health problems. It is well known that the indoor spaces are more polluted than outdoor ones, which can be a major health problem for those that live in urban areas who spend most of their time indoors. In Korea, studies on indoor air pollution are usually conducted under the auspices of academic research, which only focus on particular types of indoor spaces and certain concepts of indoor air quality. Thus, at present, the studies on the policies or policy measures concerning indoor air quality management are difficult to find in the country. The governmental agencies that are presently involved in the management of indoor air quality include: the Ministry of Health and Welfare, Ministry of Construction and Transportation, Ministry of Education and Human Resources Development, and Ministry of Environment. However, due to differing regulatory standards between the concerned agencies, the national management of indoor air quality has so far proven to be ineffective. Although the Ministry of Environment recently proposed a law to manage indoor air quality, it is only focuses on managing particular types of indoor spaces not regulated by other governmental bodies and is not effective in the effort towards a national managing system for indoor air pollution. According to a survey conducted by the Korea Environment Institute (KEI), the residents of the Seoul metropolitan area have been felt that environmental pollution negatively affects their health, and especially consider outdoor air pollution to be the most harmful type of pollution. Although these urban residents spend more than 20 hours a day indoors, the survey shows that they do not

  7. HVAC design guidelines for effective indoor air quality

    International Nuclear Information System (INIS)

    Bladykas, M.P.

    1993-01-01

    Building owners, designers and occupants need to consider all the design measures that contribute to high indoor air quality. Building occupants, furnishings, equipment, and ambient air pollution all contribute to surmounting indoor air quality concerns. However, these can be minimized by following HVAC design guidelines which promote high indoor air quality while maintaining reasonable energy-efficiency. The possible liabilities and loss of business productivity due to air quality problems are too great to ignore

  8. ASSOCIATIONS BETWEEN SEASONAL SLEEP CHANGE AND INDOOR TANNING1,2

    OpenAIRE

    CULNAN, ELIZABETH; KLOSS, JACQUELINE D.; DARLOW, SUSAN; HECKMAN, CAROLYN J.

    2015-01-01

    Identification of risk factors for indoor tanning may ultimately aid the development of better indoor tanning prevention strategies, which is pertinent given the association between indoor tanning and skin cancer. This study aimed to examine the relationship between seasonal sleep change and indoor tanning. Women tanners (N= 139) completed self-report measures including items relating to seasonal sleep changes, seasonal affective disorder (SAD), reasons for tanning, tanning during the winter ...

  9. [Indoor air pollution in southeast Santiago, Chile].

    Science.gov (United States)

    Pino, P; Oyarzún, M; Walter, T; von Baer, D; Romieu, I

    1998-04-01

    Indoor air pollution could play an important role in the susceptibility to respiratory diseases of vulnerable individuals, such as elders and infants. To evaluate indoor air pollution in a low income population of South East Santiago. A domiciliary survey of contaminant sources was carried out in the bouses of a cohort of 522 children less than one year old. Using a case-control design, 121 children consulting for respiratory diseases were considered as cases and 131 healthy infants of the same age and sex were considered as controls. In the houses of both groups, active monitors for particulate matter (PM10) and passive monitors for NO2 were installed. Forty two percent of fathers and 30% of mothers were smokers, and in two thirds of the families there was at least one smoker. Eighty five percent used portable heaters in winter. Of these, 77% used kerosene as fuel. Only 27% had water heating appliances. The rest heated water on the kitchen store or on bonfires. Most kitchen stoves used liquid gas as fuel. Twenty four hour PM10 was 109 +/- 3.2 micrograms/m3. Mean indoor and outdoor NO2 in 24 h was 108 +/- 76.3 and 84 +/- 53.6 micrograms/m3 respectively. Indoor NO2 levels were related to the use of heating devices and smoking. No differences in PM10 and NO2 levels were observed between cases and controls. There is a clear relationship between indoor pollution and contaminating sources. Indoor NO2 levels are higher than outdoors.

  10. Indoor climate optimization with limited resources

    DEFF Research Database (Denmark)

    Santos, A.; Gunnarsen, Lars Bo

    This report presents experimental data and models for optimisation of the indoor climate parameters temperature, noise, draught and window opening. Results are based on experiments with human subjects performed in climate chambers at University of the Philippines. The report may assist building...... designers to balance attention and resources between the parameters of the indoor climate when resources are less than optimal....

  11. A Breath of Fresh Air: Addressing Indoor Air Quality

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  12. Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings

    International Nuclear Information System (INIS)

    Clarisse, B.; Laurent, A.M.; Seta, N.; Le Moullec, Y.; El Hasnaoui, A.; Momas, I.

    2003-01-01

    The recent increased prevalence of childhood asthma and atopy has brought into question the impact of outdoor pollutants and indoor air quality. The contributory role of aldehydes to this problem and the fact that they are mainly derived from the domestic environment make them of particular interest. This study therefore measures six different aldehyde levels in Paris dwellings from potentially different sources and identifies their indoor determinants. The study was carried out in the three principal rooms of 61 flats with no previous history of complaint for olfactory nuisance or specific symptoms, two-thirds of the flats having been recently refurbished. Aldehydes were sampled in these rooms using passive samplers, and a questionnaire on potential aldehyde sources was filled out at the same time. A multiple linear regression model was used to investigate indoor aldehyde determinants. Our study revealed that propionaldehyde and benzaldehyde were of minor importance compared to formaldehyde, acetaldehyde, pentanal, and hexanal. We found that levels of these last four compounds depended on the age of wall or floor coverings (renovations less than 1 year old), smoking, and ambient parameters (carbon dioxide levels, temperature). These results could help in the assessment of indoor aldehyde emissions

  13. Radon and aldehyde concentrations in the indoor environment. Final report

    International Nuclear Information System (INIS)

    Moschandreas, D.J.; Rector, H.E.

    1981-04-01

    Findings regarding indoor air contaminants in the energy-efficient residence (EER) in Mt. Airy, Maryland are reported. The objectives of the study were to collect and analyze relevant air quality samples (specifically radon and aldehydes), characterize the indoor air quality with respect to radon and aldehydes, and develop relationships between air infiltration rates and contaminant levels. One-fifth of the measured formaldehyde concentrations were in the range that may cause health concerns. Although indoor temperature and relative humidity affect indoor HCHO concentration, the elevated formaldehyde concentrations were measured under very low air infiltration rates. The data show that ventilation of the indoor air space is somewhat effective in reducing high HCHO concentrations. The operation of the heat exchanger led to an increase of the air infiltration rate which in turn resulted in substantial reduction of formaldehyde concentrations. A considerable number of the collected samples of indoor air displayed radon concentrations at levels higher than 1.0 to 4.0 nCim -3 (assuming an equilibrium factor of 0.5, these radon levels would correspond to working levels above the health guidelines suggested by the US EPA for homes in Florida built on land reclaimed from phosphate mining). As in the case of indoor formaldehyde concentrations, elevated indoor concentrations are substantially reduced when the infiltration rate is increased. The data base shows that the use of the air to air heat exchanger leads to reduction of indoor radon concentration by increasing the residential ventilation rate

  14. Towards Indoor Transportation Mode Detection using Mobile Sensing

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2015-01-01

    Transportation mode detection is a growing field of research, in which a variety of methods have been developed for detecting transportation modes foremost for outdoor travels. It has been employed in application areas such as public transportation, environmental footprint profiling, and context......-aware mobile assistants. For indoor travels the problem of transportation mode detection has received comparatively little attention, even though diverse transportation modes, such as biking, electric vehicles, and scooters, are used indoors, especially in large building complexes. The potential applications...... are diverse, may also extend beyond indoor variants of the above outdoor applications, and include, e.g., scheduling and progress tracking for mobile workers, management of vehicular resources, and navigation support. However, for indoor transportation mode detection, both the physical environment as well...

  15. CFD evaluation of natural ventilation of indoor environments by the concentration decay method : CO2 gas dispersion from a semi-enclosed stadium

    NARCIS (Netherlands)

    Hooff, van T.A.J.; Blocken, B.J.E.

    2013-01-01

    Computational Fluid Dynamics (CFD) simulations can be used to assess indoor natural ventilation by solving the interaction between the urban wind flow and the indoor airflow. The air exchange rate (ACH) can be obtained from the simulated volume flow rates through the ventilation openings or by the

  16. Factors influencing indoor concentrations of radon and daughter products

    International Nuclear Information System (INIS)

    Wang Hengde

    1985-01-01

    The correlation between indoor concentrations of 222 Rn and its daughters and some influencing factors is discussed and expressions of concentrations are derived with relation to radon exhalation rate from indoor surfaces, air exchange rate and daughter deposition velocities on indoor surfaces. Experimental methods for determining radon exhalation rate, air exchange rate and daughter deposition velocities are also mentioned

  17. Current implications of past DDT indoor spraying in Oman.

    Science.gov (United States)

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Indoor Air Quality and Asthma

    Directory of Open Access Journals (Sweden)

    Robert Golden

    2017-02-01

    Full Text Available Numerous contaminants in indoor air and their potential to cause or exacerbate asthma continue to be a subject of public health concern. Many agents are causally associated with or can exacerbate asthma, particularly in children. For formaldehyde, an established respiratory irritant based on numerous studies, the evidence for an association with asthma is still considered only limited or suggestive. However, there is no evidence that indicates increased sensitivity to sensory irritation to formaldehyde in people often regarded as susceptible such as asthmatics. Acrolein, but not formaldehyde, was significantly associated with asthma in a large cohort of children. This prompted an evaluation of this highly irritating chemical that had never previously been considered in the context of the indoor air/childhood asthma issue. Because acrolein is more potent than formaldehyde as a respiratory irritant and ubiquitous in indoor air, it is plausible that previous studies on potential risk factors and childhood asthma may be confounded by formaldehyde acting as an unrecognized proxy for acrolein.

  19. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  20. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  1. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  2. Indoor environment and children's health: recent developments in chemical, biological, physical and social aspects.

    Science.gov (United States)

    Le Cann, Pierre; Bonvallot, Nathalie; Glorennec, Philippe; Deguen, Séverine; Goeury, Christophe; Le Bot, Barbara

    2011-12-01

    Much research is being carried out into indoor exposure to harmful agents. This review focused on the impact on children's health, taking a broad approach to the indoor environment and including chemical, microbial, physical and social aspects. Papers published from 2006 onwards were reviewed, with regards to scientific context. Most of publications dealt with chemical exposure. Apart from the ongoing issue of combustion by-products, most of these papers concerned semi volatile organic compounds (such as phthalates). These may be associated with neurotoxic, reprotoxic or respiratory effects and may, therefore, be of particular interest so far as children are concerned. In a lesser extent, volatile organic compounds (such as aldehydes) that have mainly respiratory effects are still studied. Assessing exposure to metals is still of concern, with increasing interest in bioaccessibility. Most of the papers on microbial exposure focused on respiratory tract infections, especially asthma linked to allergens and bio-aerosols. Physical exposure includes noise and electromagnetic fields, and articles dealt with the auditory and non auditory effects of noise. Articles on radiofrequency electromagnetic fields mainly concerned questions about non-thermal effects and papers on extremely low-frequency magnetic fields focused on the characterization of exposure. The impact of the indoor environment on children's health cannot be assessed merely by considering the effect of these different types of exposure: this review highlights new findings and also discusses the interactions between agents in indoor environments and also with social aspects. Copyright © 2011 Elsevier GmbH. All rights reserved.

  3. Development of molecular tools for rapid detection and quantification of indoor airborne molds to assess their impact on public health

    OpenAIRE

    Libert, Xavier

    2017-01-01

    Currently, contamination of the indoor environment by fungi is suggested to be a public health problem, although scientific evidence on the causal link is still limited. The monitoring of indoor airborne fungal contamination is a common tool to help understanding the link between fungi in houses and respiratory problems. Classical monitoring methods, based on cultivation and microscopic identification, have some limitations. For example, uncultivable or dead fungi (“unknown” fraction) cannot ...

  4. Light fidelity (LI-FI) based indoor communication system

    OpenAIRE

    Aftab, Farooq; khan, Muhammad Nafees Ulfat; Ali, Shahzad

    2016-01-01

    Indoor wireless communication is an essential part of next generation wireless communication system.For an indoor communication number of users and their device are increasing very rapidly so as a result capacity of frequency spectrum to accommodate further users in future is limited and also it would be difficult for service providers to provide more user reliable and high speed communication so this short come can be solve in future by using Li-Fi based indoor communication syst...

  5. FIELD COMPARISONS OF DUAL SMPS-APS SYSTEMS TO MEASURE INDOOR-OUTDOOR PARTICLE SIZE DISTRIBUTIONS

    Science.gov (United States)

    Simultaneous measurements of particle size distributions across multiple locations can provide critical information to accurately assess human exposure to particles. These data are very useful to describe indoor-outdoor particle relationships, outdoor particle penetration thro...

  6. Evaluation of the Indoor Environment in the Comfort Houses

    DEFF Research Database (Denmark)

    Brunsgaard, Camilla; Heiselberg, Per; Knudstrup, Mary-Ann

    2012-01-01

    and in a process of doing so, it is important to maintain a good and healthy indoor environment and not on the expense of it. One way of saving energy is to build passive houses. This paper presents the result of a case study of some of the first certified passive houses in Denmark, called the Comfort Houses....... The paper evaluates the indoor environment through both quantitative measurements in the houses and qualitative interviews with the occupants about their experiences of the indoor environment. Two set of knowledge which together gives a more complete and holistic picture of the indoor environment. The study...

  7. EVALUATION OF AIR PURIFICATION DEVICES FOR CONTROL OF INDOOR PM

    Science.gov (United States)

    Because people spend most of their time indoors (89%), the indoor environment is a primary determinant of particle exposure. The indoor environment is especially an important determinant for the very young, the very old, and those with underlying cardiopulmonary disease because...

  8. CFD simulation research on residential indoor air quality.

    Science.gov (United States)

    Yang, Li; Ye, Miao; He, Bao-Jie

    2014-02-15

    Nowadays people are excessively depending on air conditioning to create a comfortable indoor environment, but it could cause some health problems in a long run. In this paper, wind velocity field, temperature field and air age field in a bedroom with wall-hanging air conditioning running in summer are analyzed by CFD numerical simulation technology. The results show that wall-hanging air conditioning system can undertake indoor heat load and conduct good indoor thermal comfort. In terms of wind velocity, air speed in activity area where people sit and stand is moderate, most of which cannot feel wind flow and meet the summer indoor wind comfort requirement. However, for air quality, there are local areas without ventilation and toxic gases not discharged in time. Therefore it is necessary to take effective measures to improve air quality. Compared with the traditional measurement method, CFD software has many advantages in simulating indoor environment, so it is hopeful for humans to create a more comfortable, healthy living environment by CFD in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Pilot study on indoor climate investigation and computer simulation in historical museum building: Amerongen Castle, the Netherlands

    Directory of Open Access Journals (Sweden)

    Raha Sulaiman

    2010-12-01

    Full Text Available The indoor climate is one of the most important factors contributing to climate-induced damage to the building materials and cultural collections of a monumental building. The Dutch monumental building - Amerongen Castle, and the collections housed in it show severe deterioration caused by inappropriate historical indoor environment. Assessments of the indoor climate, especially on the room temperature and relative humidity, are necessary to analyze the causes and impacts of climate change. As the building was flooded in year 1993 and 1996, extra attention is paid to investigate the effects of flooding to it. This pilot study was aimed to identify the buildup linkages between the known past, historical data on indoor environment and indoor climate performance in the building through simulation based-prediction. This paper focuses on the methodology of indoor climate investigation from the past to the current situation. A hypothesis was developed on backcasting-based prediction simulation which can be used to identify the accepted historical indoor climate where during those times there probably was no damage to the building and the collection. A simulation method based on heat, air and moisture transport is used with the HAMBase program. The computer model representing the Grand Salon of Amerongen Castle was calibrated by comparing real measurements to simulation results. It shows that the differences were only to the minimum of -1.8C and maximum of 3.2C. The data for the historical outdoor weather files was obtained by interpolating outdoor ancient climatology constructed by MATLAB. Based on archival research, indoor thermal history was gathered as input for the profiles used in simulation. Further, the calibrated computer model can be used to simulate past indoor climate and investigate the process of the deterioration of the room and the collections mainly due to the fluctuation of indoor temperature and relative humidity. At the end

  10. The right to healthy indoor air: Status by 2002

    DEFF Research Database (Denmark)

    Mølhave, Lars; Krzyzanowski, M.

    2003-01-01

    . The discussions and statements are available as a WHO report. It informs the individuals and groups responsible for healthy indoor air about their rights and obligations, and empowers the general public by making people familiar with those rights. One year after their publication the statements have been adopted......One of the reasons for the inadequate quality of indoor air arises from the poor articulation, appreciation and understanding of basic principles underlying the policies and actions related to indoor air quality. A WHO Working Group derived nine statements on rights to healthy indoor air...... as the base for future regulation and guidance. The Board of Directors of the International Society of Indoor Air Quality (ISIAQ) and the participants of two international conferences endorse the use of the statements. No opposition to the statements have been registered. The statements have entered curricula...

  11. Status of the indoor climate labelling scheme in Denmark

    DEFF Research Database (Denmark)

    Witterseh, Thomas

    2002-01-01

    The impartial Indoor Climate Labelling, ICL, originally introduced in Denmark to reduce emissions from building materials and products used in the indoor environment, is still developing and consolidating its position. The ICL benefits from an expansion of the product areas covered and a still...... increasing number of labelled products. The product area of furniture is now included, making a total of ten different product areas. Approximately 100 different groups of products are included, which individually covers a number of specific products. An increasing number of manufacturers apply...... for the Indoor Climate Label, due to a growing concern about the indoor environment among architects, consulting and planning engineers and private consumers. This shows that the concept is now working as originally intended. A goal for the ICL is to develop a method for labelling of the overall indoor...

  12. Presentation on ecoenergetic assessment

    International Nuclear Information System (INIS)

    Fournelle, C.

    1998-01-01

    The development of a tool to assess the quality of indoor air for buildings in the residential and commercial sector was presented. The computer software program was designed to allow a building operator to set an optimal target to reflect the greatest economies in energy consumption. Air quality was assessed in terms of carbon dioxide, volatile organic compounds, and other common indoor pollutants

  13. Human Exposure Assessment for Air Pollution.

    Science.gov (United States)

    Han, Bin; Hu, Li-Wen; Bai, Zhipeng

    2017-01-01

    Assessment of human exposure to air pollution is a fundamental part of the more general process of health risk assessment. The measurement methods for exposure assessment now include personal exposure monitoring, indoor-outdoor sampling, mobile monitoring, and exposure assessment modeling (such as proximity models, interpolation model, air dispersion models, and land-use regression (LUR) models). Among these methods, personal exposure measurement is considered to be the most accurate method of pollutant exposure assessment until now, since it can better quantify observed differences and better reflect exposure among smaller groups of people at ground level. And since the great differences of geographical environment, source distribution, pollution characteristics, economic conditions, and living habits, there is a wide range of differences between indoor, outdoor, and individual air pollution exposure in different regions of China. In general, the indoor particles in most Chinese families comprise infiltrated outdoor particles, particles generated indoors, and a few secondary organic aerosol particles, and in most cases, outdoor particle pollution concentrations are a major contributor to indoor concentrations in China. Furthermore, since the time, energy, and expense are limited, it is difficult to measure the concentration of pollutants for each individual. In recent years, obtaining the concentration of air pollutants by using a variety of exposure assessment models is becoming a main method which could solve the problem of the increasing number of individuals in epidemiology studies.

  14. Investigation on Moisture and Indoor Environment in Eight Danish Houses

    DEFF Research Database (Denmark)

    Jensen, Kasper Risgaard; Jensen, Rasmus Lund; Nørgaard, Jesper

    2011-01-01

    then need to be ventilated actively either by natural or mechanical ventilation. Increased focus on energy reduction together with requirements for e.g. thermal comfort indoors may lead to reduced indoor air quality and moisture problems which in turn may cause mould problems. This paper describes...... an investigation of the indoor air quality, relative humidity and air change rate in eight Danish houses. The houses were selected as they are all having recurrent problems with condensation on the windows. The houses were built between 1930 and 2007. Some of them have been only slightly renovated where others......, to indoor air quality in terms of CO2 concentration, and to the use of the house in terms of the level of the relative humidity and indoor moisture excess. Furthermore, the moisture production in the houses was estimated and compared to values provided in the literature. A better indoor air quality...

  15. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, S

    2010-01-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  16. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, SA

    2010-04-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  17. Host characteristics, sun exposure, indoor tanning and risk of squamous cell carcinoma of the skin.

    Science.gov (United States)

    Veierød, Marit B; Couto, Elisabeth; Lund, Eiliv; Adami, Hans-Olov; Weiderpass, Elisabete

    2014-07-15

    Use of indoor tanning devices increases risk of cutaneous malignant melanoma, but the association with risk of squamous cell carcinoma (SCC) of the skin is unclear. Cohort studies of SCC risk are rare and we aimed to assess the association between SCC risk and host characteristics, sun exposure, and indoor tanning in a population-based cohort of Norwegian and Swedish women conjunctly with SCC incidence data from national cancer registries. Host characteristics and exposure to sun and indoor tanning devices before 50-years old were recorded by questionnaire at inclusion (30-50 years) in 1991/92. Multivariable relative risks (RRs) and 95% confidence intervals (CIs) were estimated by Poisson regression. During follow-up of 106,548 women through December 2009, SCC was diagnosed in 141 women. Skin sensitivity to acute sun exposure was the most important pigmentation characteristic (RR = 2.73, 95% CI 1.47-5.05, for red with pain/red with pain and blisters versus brown). We found no consistent associations with sunburns and bathing vacations in the first five age decades, but a significant positive trend for bathing vacations summarized over ages 10-49 years (Ptrend  = 0.02). We also found significantly increased risks of SCC following indoor tanning at age 40-49 years (RR = 2.17, 95% CI 1.29-3.67, for ≥ 1 time/month versus never) and indoor tanning summarized over ages 10-49 years (Ptrend  = 0.001). RR for ever versus never use of indoor tanning over ages 10-49 years was 1.93 (95% CI 1.27-2.95). Propensity to burn was an important host characteristic, and bathing vacations and indoor tanning summarized over ages 10-49 years increased SCC risk. © 2013 UICC.

  18. Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.; Shi, K.L.

    2008-01-01

    Air-conditioned office buildings are one of the biggest energy consumers of electricity in developed cities in the subtropical climate regions. A good energy policy for the indoor environment should respond to both the needs of energy conservation and the needs for a desirable indoor healthy environment with a reduction in carbon dioxide (CO 2 ) generation. This study evaluates energy implications and the corresponding CO 2 generation of some indoor environmental policies for air-conditioned office buildings in the subtropical climate. In particular, the thermal energy consumption in an air-conditioned office building was evaluated by the heat gains through the building fabric, the transport of outdoor fresh air for ventilation, and the heat generated by the occupant and equipment in the space. With the Monte-Carlo sampling technique and the parameters from the existing office building stocks of Hong Kong, the energy consumption profiles of air-conditioned office buildings in Hong Kong were evaluated. Energy consumption profiles were simulated for certain indoor environmental quality (IEQ) policies on indoor air temperature and CO 2 concentration settings in the offices, with other building parameters remaining unchanged. The impact assessment and the regression models described in this study may be useful for evaluation of energy performances of IEQ policies. They will also be useful for the promotion of energy-saving measures in air-conditioned office buildings in Hong Kong. This study presented a useful source of references for policymakers, building professionals and end users to quantify the energy and environmental impacts due to an IEQ policy for air-conditioned office buildings

  19. Diversity and taxonomy of Chaetomium and chaetomium-like fungi from indoor environments

    Directory of Open Access Journals (Sweden)

    X.W. Wang

    2016-06-01

    Full Text Available During a study of indoor fungi, 145 isolates belonging to Chaetomiaceae were cultured from air, swab and dust samples from 19 countries. Based on the phylogenetic analyses of DNA-directed RNA polymerase II second largest subunit (rpb2, β-tubulin (tub2, ITS and 28S large subunit (LSU nrDNA sequences, together with morphological comparisons with related genera and species, 30 indoor taxa are recognised, of which 22 represent known species, seven are described as new, and one remains to be identified to species level. In our collection, 69 % of the indoor isolates with six species cluster with members of the Chaetomium globosum species complex, representing Chaetomium sensu stricto. The other indoor species fall into nine lineages that are separated from each other with several known chaetomiaceous genera occurring among them. No generic names are available for five of those lineages, and the following new genera are introduced here: Amesia with three indoor species, Arcopilus with one indoor species, Collariella with four indoor species, Dichotomopilus with seven indoor species and Ovatospora with two indoor species. The generic concept of Botryotrichum is expanded to include Emilmuelleria and the chaetomium-like species B. muromum (= Ch. murorum in which two indoor species are included. The generic concept of Subramaniula is expanded to include several chaetomium-like taxa as well as one indoor species. Humicola is recognised as a distinct genus including two indoor taxa. According to this study, Ch. globosum is the most abundant Chaetomiaceae indoor species (74/145, followed by Ch. cochliodes (17/145, Ch. elatum (6/145 and B. piluliferum (5/145. The morphological diversity of indoor Chaetomiaceae as well as the morphological characteristics of the new genera are described and illustrated. This taxonomic study redefines the generic concept of Chaetomium and provides new insight into the phylogenetic relationships among different genera within

  20. Bluetooth Indoor Positioning System using Fingerprinting

    DEFF Research Database (Denmark)

    Frost, Christian; Jensen, Casper Svenning; Luckow, Kasper Søe

    2011-01-01

    Indoor Positioning has been an active research area in the last decade, but so far, commercial Indoor Positioning Systems (IPSs) have been sparse. The main obstacle towards widely available IPSs has been the lack of appropriate, low cost technologies, that enable indoor positioning. While Wi-Fi...... infrastructures are ubiquitous, consumer-oriented Wi-Fi enabled mobile phones have been missing. Conversely, while Bluetooth technology is present in the vast majority of consumer mobile phones, Bluetooth infrastructures have been missing. Bluetooth infrastructures have typically been installed as part...... of complete hardware/software IPSs that often incur a substantial hardware cost. Furthermore, Bluetooth has low power consumption compared to Wi-Fi devices, which promotes longer battery life-time on mobile phones. In this paper, we present a Bluetooth IPS based entirely on commodity-grade products...

  1. Indoor radon levels in coastal Karnataka

    International Nuclear Information System (INIS)

    Narayana, Y.; Radhakrishna, A.P.; Somashekarappa, H.M.; Karunakara, N.; Balakrishna, K.M.; Siddappa, K.

    1995-01-01

    Indoor radon levels have been measured in selected dwellings of coastal Karnataka using LR-115 type II peelable films and it is found to vary from 28.4 to 45.6 Bq m -3 with a geometric mean value of 35.7 Bq m -3 . The annual effective dose equivalent to the population of the region due to inhalation of radon was estimated from the measured data on radon level and is found to be in the range 1.9 - 3.1 mSv y -1 with a mean value 2.4 mSv y -1 . The correlation between indoor radon level and radium content in the underlying soil were studied. No definite correlation was observed to exist between indoor radon level and radium content in soil. (author). 24 refs., 2 tabs

  2. Indoor air quality at nine shopping malls in Hong Kong.

    Science.gov (United States)

    Li, W M; Lee, S C; Chan, L Y

    2001-06-12

    Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.

  3. Natural indoor gamma background in Coonoor environment of South India

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikand, N.; Raghunath, V.M.

    2002-01-01

    Indoor natural radiation dose existing in dwellings of Coonoor have been estimated using thermoluminescent dosimeters. TLDs are displayed in indoors and are replaced after three-month period. The seasonal averages of the dose rate and the annual effective dose equivalent are calculated from the measured results. Geographical and seasonal variations as well as the differences between indoor to outdoor dose rates have also been studied. Very good correlation exists between the indoor dose rates measured by LTD and environmental radiation dosimeter with correlation coefficient of 0.91. The annual effective dose equivalent to the Coonoor population due to indoor gamma radiation was estimated to be 970 μSv/y for the period of 1997-1998. (author)

  4. Reducing health risks from indoor exposures in rapidly developing urban China.

    Science.gov (United States)

    Zhang, Yinping; Mo, Jinhan; Weschler, Charles J

    2013-07-01

    Over the past two decades there has been a large migration of China's population from rural to urban regions. At the same time, residences in cities have changed in character from single-story or low-rise buildings to high-rise structures constructed and furnished with many synthetic materials. As a consequence, indoor exposures (to pollutants with outdoor and indoor sources) have changed significantly. We briefly discuss the inferred impact that urbanization and modernization have had on indoor exposures and public health in China. We argue that growing adverse health costs associated with these changes are not inevitable, and we present steps that could be taken to reduce indoor exposures to harmful pollutants. As documented by China's Ministry of Health, there have been significant increases in morbidity and mortality among urban residents over the past 20 years. Evidence suggests that the population's exposure to air pollutants has contributed to increases in lung cancer, cardiovascular disease, pulmonary disease, and birth defects. Whether a pollutant has an outdoor or an indoor source, most exposure to the pollutant occurs indoors. Going forward, indoor exposures can be reduced by limiting the ingress of outdoor pollutants (while providing adequate ventilation with clean air), minimizing indoor sources of pollutants, updating government policies related to indoor pollution, and addressing indoor air quality during a building's initial design. Taking the suggested steps could lead to significant reductions in morbidity and mortality, greatly reducing the societal costs associated with pollutant derived ill health.

  5. Air-Sense: indoor environment monitoring evaluation system based on ZigBee network

    Science.gov (United States)

    Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang

    2017-08-01

    In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.

  6. Indoor radon seasonal variability at different floors of buildings

    International Nuclear Information System (INIS)

    De Francesco, S.; Tommasone, F. Pascale; Cuoco, E.; Tedesco, D.

    2010-01-01

    Indoor radon concentrations have been measured with the α track etch integrated method in public buildings in the town of Pietramelara, north-western Campania, Southern Italy. In particular, our measurements were part of an environmental monitoring program originally aimed at assessing the range of seasonal fluctuations in indoor radon concentrations, at various floors of the studied buildings. However, subsequent analysis of the data and its comparison with the meteorological data recorded in the same period has shown an unexpected pattern at the different floors. In this report we present data suggesting that, besides the well-known medium and longterm periodicity, there could also be a differentiation in major meteorological controlling factors at the different floors of the buildings, a fact that does not appear to have been reported previously. While the lower floors proved to be markedly affected by rainfall, for the upper floors, instead, a different behaviour has been detected, which could possibly be related to global solar radiation.

  7. Finding dense locations in symbolic indoor tracking data

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2017-01-01

    presents two graph-based models for constrained and semi-constrained indoor movement, respectively, and then uses the models to map raw tracking records into mapping records that represent object entry and exit times in particular locations. Subsequently, an efficient indexing structure called Hierarchical...... Dense Location Time Index (HDLT-Index) is proposed for indexing the time intervals of the mapping table, along with index construction, query processing, and pruning techniques. The HDLT-Index supports very efficient aggregate point, interval, and duration queries as well as dense location queries......Finding the dense locations in large indoor spaces is very useful for many applications such as overloaded area detection, security control, crowd management, indoor navigation, and so on. Indoor tracking data can be enormous and are not immediately ready for finding dense locations. This paper...

  8. Indoor environmental health in schools

    Energy Technology Data Exchange (ETDEWEB)

    Small, B.M. [Envirodesic Certification Program, Stouffville, ON (Canada)

    1999-07-01

    Indoor health is a concern today because unhealthy environments can cause adverse health effects, poor learning and teaching and increased costs. The holistic view of the environment and human health links sick kids, absenteeism, teacher illness, education costs and mouldy schools. An historical perspective is provided on the problem and its treatment referring to: 1962 and chemical susceptibility, 1975 and open systems theory, 1978 and high risk groups, 1985 and pollution and education in Toronto, 1987 and health environments for Canadians, 1995 and the National Education Association in the U.S., 1997 and a U.S. Executive Order, 1998 and the Texas Dept. of Health, 1998 and the U.S. EPS website 'IAQ Tools for Schools', and 1998 and 'The air children breathe.' It is known that pollutants adversely affect health, that children are highly susceptible, that the role in schools has being known for decades, and that information is now available worldwide through the Internet. The reasons why mould is a problem are listed, and the effects of an unhealthy indoor environment are referred to. The benefits of a healthy indoor environment are listed, and the various means of creating a healthy indoor environment are outlined. New developments are referred to including: fresh air, building envelope, building leakage, airtightness of buildings, tight envelope and air supply, low-emission materials, maintenance and cleaning, strategy and financing, collaboration, and the possibility of healthy schools.

  9. Hierarchical modeling of indoor radon concentration: how much do geology and building factors matter?

    International Nuclear Information System (INIS)

    Borgoni, Riccardo; De Francesco, Davide; De Bartolo, Daniela; Tzavidis, Nikos

    2014-01-01

    Radon is a natural gas known to be the main contributor to natural background radiation exposure and only second to smoking as major leading cause of lung cancer. The main concern is in indoor environments where the gas tends to accumulate and can reach high concentrations. The primary contributor of this gas into the building is from the soil although architectonic characteristics, such as building materials, can largely affect concentration values. Understanding the factors affecting the concentration in dwellings and workplaces is important both in prevention, when the construction of a new building is being planned, and in mitigation when the amount of Radon detected inside a building is too high. In this paper we investigate how several factors, such as geologic typologies of the soil and a range of building characteristics, impact on indoor concentration focusing, in particular, on how concentration changes as a function of the floor level. Adopting a mixed effects model to account for the hierarchical nature of the data, we also quantify the extent to which such measurable factors manage to explain the variability of indoor radon concentration. - Highlights: • It is assessed how the variability of indoor radon concentration depends on buildings and lithologies. • The lithological component has been found less relevant than the building one. • Radon-prone lithologies have been identified. • The effect of the floor where the room is located has been estimated. • Indoor radon concentration have been predicted for different dwelling typologies

  10. Online Risk Prediction for Indoor Moving Objects

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Calders, Toon

    2016-01-01

    Technologies such as RFID and Bluetooth have received considerable attention for tracking indoor moving objects. In a time-critical indoor tracking scenario such as airport baggage handling, a bag has to move through a sequence of locations until it is loaded into the aircraft. Inefficiency or in...... reduce the operation cost....

  11. Surface-deposition and distribution of the radon-decay products indoors

    International Nuclear Information System (INIS)

    Espinosa, G.; Tommasino, L.

    2015-01-01

    The exposure to radon-decay products is of great concern both in dwellings and workplaces. The model to estimate the lung dose refers to the deposition mechanisms and particle sizes. Unfortunately, most of the dose data available are based on the measurement of radon concentration and the concentration of radon decay products. These combined measurements are widely used in spite of the fact that accurate dose assessments require information on the particle deposition mechanisms and the spatial distribution of radon decay products indoors. Most of the airborne particles and/or radon decay products are deposited onto indoor surfaces, which deposition makes the radon decay products unavailable for inhalation. These deposition processes, if properly known, could be successfully exploited to reduce the exposure to radon decay products. In spite of the importance of the surface deposition of the radon decay products, both for the correct evaluation of the dose and for reducing the exposure; little or no efforts have been made to investigate these deposition processes. Recently, two parallel investigations have been carried out in Rome and at Universidad Nacional Autónoma de México (UNAM) in Mexico City respectively, which address the issue of the surface-deposited radon decay products. Even though these investigations have been carried independently, they complement one another. It is with these considerations in mind that it was decided to report both investigations in the same paper. - Highlights: • Distribution of Radon and Thoron decay indoor products. • Indoor radon measurements complexity. • Short and long term measurements of surface deposit of Radon and Thoron decay products. • Microclimate controlled conditions room. • Nuclear Tracks Detectors

  12. Exploring the consequences of climate change for indoor air quality

    International Nuclear Information System (INIS)

    Nazaroff, William W

    2013-01-01

    Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. (letter)

  13. Standards for securing adequate indoor air quality across Europe

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Carrer, P.; de Oliveira Fernandes, E.

    2013-01-01

    Background: Inadequate IAQ causes a loss of 2 million healthy life years annually in the EU. Europeans spend typically over 85–90% of their time indoors and the main factors that affect negatively the characteristics of the air they breathe are outdoor air used to ventilate indoor spaces and indoor...... effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types...... and is determined mainly considering the metabolic CO2 production. It is only applicable if all other pollutants meet WHO guidelines for ambient and indoor air quality. If they do not meet these guidelines after applying source control and when air used for ventilation is clean health-based ventilation rate should...

  14. Indoor air quality in public utility environments-a review.

    Science.gov (United States)

    Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena

    2017-04-01

    Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.

  15. Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing.

    Science.gov (United States)

    Zuo, JinXing; Ji, Wei; Ben, YuJie; Hassan, Muhammad Azher; Fan, WenHong; Bates, Liam; Dong, ZhaoMin

    2018-05-19

    Due to time- and expense- consuming of conventional indoor PM 2.5 (particulate matter with aerodynamic diameter of less than 2.5 μm) sampling, the sample size in previous studies was generally small, which leaded to high heterogeneity in indoor PM 2.5 exposure assessment. Based on 4403 indoor air monitors in Beijing, this study evaluated indoor PM 2.5 exposure from 15th March 2016 to 14th March 2017. Indoor PM 2.5 concentration in Beijing was estimated to be 38.6 ± 18.4 μg/m 3 . Specifically, the concentration in non-heating season was 34.9 ± 15.8 μg/m 3 , which was 24% lower than that in heating season (46.1 ± 21.2 μg/m 3 ). A significant correlation between indoor and ambient PM 2.5 (p < 0.05) was evident with an infiltration factor of 0.21, and the ambient PM 2.5 contributed approximately 52% and 42% to indoor PM 2.5 for non-heating and heating seasons, respectively. Meanwhile, the mean indoor/outdoor (I/O) ratio was estimated to be 0.73 ± 0.54. Finally, the adjusted PM 2.5 exposure level integrating the indoor and outdoor impact was calculated to be 46.8 ± 27.4 μg/m 3 , which was approximately 42% lower than estimation only relied on ambient PM 2.5 concentration. This study is the first attempt to employ big data from commercial air monitors to evaluate indoor PM 2.5 exposure and risk in Beijing, which may be instrumental to indoor PM 2.5 pollution control. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Indoor climate and air quality . Review of current and future topics in the field of ISB study group 10

    Science.gov (United States)

    Höppe, P.; Martinac, Ivo

    In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ''sick building syndrome''.

  17. Advanced airflow distribution methods for reduction of personal exposure to indoor pollutants

    DEFF Research Database (Denmark)

    Cao, Guangyu; Kosonen, Risto; Melikov, Arsen

    2016-01-01

    The main objective of this study is to recognize possible airflow distribution methods to protect the occupants from exposure to various indoor pollutants. The fact of the increasing exposure of occupants to various indoor pollutants shows that there is an urgent need to develop advanced airflow ...... distribution methods to reduce indoor exposure to various indoor pollutants. This article presents some of the latest development of advanced airflow distribution methods to reduce indoor exposure in various types of buildings.......The main objective of this study is to recognize possible airflow distribution methods to protect the occupants from exposure to various indoor pollutants. The fact of the increasing exposure of occupants to various indoor pollutants shows that there is an urgent need to develop advanced airflow...

  18. Indexing the Trajectories of Moving Objects in Symbolic Indoor Space

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lu, Hua; Yang, Bin

    2009-01-01

    . This scenario calls for the indexing of indoor trajectories. Based on an appropriate notion of indoor trajectory and definitions of pertinent types of queries, the paper proposes two R-tree based structures for indexing object trajectories in symbolic indoor space. The RTR-tree represents a trajectory as a set......Indoor spaces accommodate large populations of individuals. With appropriate indoor positioning, e.g., Bluetooth and RFID, in place, large amounts of trajectory data result that may serve as a foundation for a wide variety of applications, e.g., space planning, way finding, and security...... for each index. An empirical performance study suggests that the two indexes are effective, efficient, and robust. The study also elicits the circumstances under which our proposals perform the best....

  19. Indoor Environment Program - 1996 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Indoor Environment Program

    1996-11-01

    The forty-five chemists, physicists, biologists, architects, engineers, staff, and students of the Indoor Environment Program are all working to solve the problems of indoor air quality, health, comfort, and energy use associated with the indoor environment. A common thread throughout this work is the importance of ventilation--both for its role in supporting human health and comfort as well as for its liability in requiring large amounts of energy to heat and cool it. The importance of understanding these interactions can be illustrated by two examples: the health and productivity of workers (Fisk and Rosenfeld, 1996) and the performance of sensitive equipment in clean room environments (Faulkner, et d., 1996). During the past year, we estimated the magnitudes of health and productivity gains that may be obtained by providing better indoor environments. The ratio of the potential financial benefits of improving indoor environments to the costs of the improvements ranges between 20 and 50. A second example is from our Clean Room Energy Efficiency Study: Clean rooms utilize large amounts of electricity to operate fans that recirculate air at very high flow rates through particle filters. Usually, the fans operate continuously at full speed, even when the clean room is unused. To reduce the energy use in a research clean room, the rate of air recirculation was controlled in response to real-time measurements of particle concentration. With this new control system, fan energy use decreased by 65% to 85% while maintaining particle concentrations below the allowable limits except during occasional one-minute periods. The estimated payback period for this technology is one to four years.

  20. Risk factors for indoor air pollution in rural households in Mauche ...

    African Journals Online (AJOL)

    Risk factors for indoor air pollution in rural households in Mauche division, Molo ... indoor air pollution, which has been associated with various diseases. Key words: biomass fuel, children, indoor pollution, respiratory infections, ventilation.

  1. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing

    Science.gov (United States)

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-01-01

    In order to identify the sources of indoor PM2.5 and to check which factors influence the concentration of indoor PM2.5 and chemical elements, indoor concentrations of PM2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM2.5 was 57.64 μg/m3. For elements in indoor PM2.5, Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM2.5, Cd and Pb was performed. Indoor PM2.5 was influenced by factors including outdoor PM2.5, smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM2.5 and its constituents. PMID:29621164

  2. Environment and development of respiratory allergy. II. Indoors.

    Science.gov (United States)

    D'Amato, G; Liccardi, G; D'Amato, M

    1994-12-01

    Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.

  3. Health effects from indoor air pollution: case studies.

    Science.gov (United States)

    White, L E; Clarkson, J R; Chang, S N

    1987-01-01

    In recent years there has been a growing awareness of the health effects associated with the presence of contaminants in indoor air. Numerous agents can accumulate in public buildings, homes and automobiles as a result of ongoing activities that normally occur in these closed spaces. Ventilation is a major factor in the control of indoor air pollutants since proper movement of air can prevent or minimize the build up of compounds in buildings. The recent emphasis on energy conservation has lead to measures which economize on energy for heating and air conditioning, but which also trap pollutants within a building. Three cases of indoor air pollution were investigated. A typical investigation of indoor air pollutant problems includes the following: interviews with building occupants; history of the building with regard to maintenance, pesticide treatment, etc.; a survey of the building and ventilation; and when warranted, sampling and analysis of air. Each case presented is unique in that atypical situations caused agents to accumulate in a building or section of a building. The indoor air problems in these cases were solved by identifying and removing the source of the offending agent and/or improving the ventilation in the building.

  4. Indoor Air Pollution in Non Ac Passenger Bus

    Science.gov (United States)

    El Husna, Iksiroh; Unzilatirrizqi, Rizal D. Yan El; Karyanto, Yudi; Sunoko, Henna R.

    2018-02-01

    Passenger buses have been one of favorite means of transportation in Indonesia due to its affordability and flexibility. Intensity of human activities during the trip in the buses have a potential of causing indoor air pollution (polusi udara dalam ruang; PUDR). The indoor air pollution has an impact of 1000-time bigger than outdoor air pollution (polusi udara luar ruang; PULR) on lung. This study aimed to find out indoor air pollution rate of non air conditioned buses using an approach to biological agent pollutant source. The study applied an analysis restricted to microorganisms persistence as one of the sources of the indoor air pollution. The media were placed in different parts of the non AC buses. This study revealed that fungs were found in the non AC buses. They became contaminants and developed pathogenic bacteria that caused air pollution.

  5. Effects of Indoor Air Pollution on Human Health

    DEFF Research Database (Denmark)

    Berglund, B.; Brunekreef, B.; Knöppel, H.

    1992-01-01

    This article contains a summary discussion of human health effects linked to indoor air pollution (UP) in homes and other non-industrial environments. Rather than discussing the health effects of the many different pollutants which can be found in indoor air, the approach has been to group broad...... these are respiratory disease (particularly among children), allergy (particularly to house dust mites) and mucous membrane irritation (particularly due to formaldehyde). Large numbers of people have been, and are still being affected. Many chemicals encountered in indoor air are known or suspected to cause sensory...... irritation or stimulation. These, in turn, may give rise to a sense of discomfort and other symptums cummonly reported in so-called “sick” buildings. Camplex mixtures of organic chemicals in indoor air also have the potential to invoke subtle effects on the central and peripheral nervous system, leading...

  6. Design Criteria for Achieving Low Radon Concentration Indoors

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving low radon concentration indoors are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most...... countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. Three criteria when used can prevent radon infiltration and lower...... the radon concentration in the indoor air. In addition, a cheap and reliable method for measuring the radon concentration in the air indoors is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause...

  7. Indoor Air Pollution in Non Ac Passenger Bus

    Directory of Open Access Journals (Sweden)

    El Husna Iksiroh

    2018-01-01

    Full Text Available Passenger buses have been one of favorite means of transportation in Indonesia due to its affordability and flexibility. Intensity of human activities during the trip in the buses have a potential of causing indoor air pollution (polusi udara dalam ruang; PUDR. The indoor air pollution has an impact of 1000-time bigger than outdoor air pollution (polusi udara luar ruang; PULR on lung. This study aimed to find out indoor air pollution rate of non air conditioned buses using an approach to biological agent pollutant source. The study applied an analysis restricted to microorganisms persistence as one of the sources of the indoor air pollution. The media were placed in different parts of the non AC buses. This study revealed that fungs were found in the non AC buses. They became contaminants and developed pathogenic bacteria that caused air pollution.

  8. Indoor air 1. Recent advances in the health science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Berglund, B; Lindvall, T; Sundell, J [eds.

    1984-01-01

    Health problems and discomfort caused by a bed indoor environment is discussed. The key note adresses in the first part of this volume covers the following subjects: Future buildings and building hygiene; Sick building syndrome; Lung cancer from radon and passive smoking; Total exposure estimation; Health implications of indoor air humidity; Indoor odors; Indoor allergies; Effect of moderate thermal stress and education of thermal discomfort; Airborne infections and modern building technology, Free radicals and oxidizing agents in the indoor air; Air quality control strategies, Achievement of the superclean environment. The seecond part of this publication contains works on policy and regulatory issues.

  9. Preventing skin cancer through reduction of indoor tanning: current evidence.

    Science.gov (United States)

    Watson, Meg; Holman, Dawn M; Fox, Kathleen A; Guy, Gery P; Seidenberg, Andrew B; Sampson, Blake P; Sinclair, Craig; Lazovich, DeAnn

    2013-06-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. Published by Elsevier Inc.

  10. Indoor Air Quality: A Guide for Educators.

    Science.gov (United States)

    California State Dept. of Education, Sacramento.

    Indoor air quality is a major concern for educators involved in the development of new school facilities, or the remodeling and maintenance of existing ones. This guide addresses the issue of air quality, the health concerns involved, and procedures for minimizing the impact of pollutants in the school environment. It defines common indoor air…

  11. Indoor air quality environmental information handbook: Building system characteristics

    International Nuclear Information System (INIS)

    1987-01-01

    This manual, the third in a series, focuses on residential building system characteristics and their effects on indoor air quality. The manual addresses: residential indoor air pollutants by source, indoor concentrations, health effects, source control and mitigation techniques, standards and guidelines; building system characteristics of air exchange, pollutant source strength, residence volume, site characteristics, structural design, construction, and operation, infiltration and ventilation system, building occupancy; and monitoring methods

  12. Investigation of infiltration and indoor air quality

    International Nuclear Information System (INIS)

    1990-03-01

    A multitask study was performed in the State of New York to provide information for guiding home energy conservation programs while maintaining acceptable indoor air quality. During the study, the statistical distribution of radon concentrations inside 2,400 homes was determined. The relationships among radon levels, house characteristics, and sources were also investigated. The direct impact that two specific air infiltration reduction measures--caulking and weatherstripping of windows and doors, and installation of storm windows and storm doors--have on house air leakage was investigated in 60 homes. The effect of house age on the impact of weatherization was also evaluated. Indoor and outdoor measurements of NO 2 , CO, SO 2 , and respirable suspended particulates (RSP) were made for 400 homes to determine the effect of combustion sources on indoor air quality and to characterize the statistical distribution of the concentrations. Finally, the combustion source data were combined with the information on air infiltration reduction measures to estimate the potential impact of these measures on indoor air quality

  13. Mortality and indoor radon daughter concentrations in 13 Canadian cities

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Wigle, D.T.

    1980-01-01

    A study was carried out to determine if lung cancer and general mortality rates in 13 Canadian cities were significantly correlated with average indoor radon daughter concentrations. The radon daughter measurements were obtained from a study of 10,000 homes chosen in a statistically valid grab sample basis. Cancer deaths by year of death, sex, age, and cause were retrieved for each of the cities for the period 1957-1976. Age specific and age standardized mortality rates were calculated. The results showed no evidence of any substantial association between general or lung cancer mortality rates and indoor radon daughter concentrations. The limitations of this study and the feasibility of a common international program of epidemiology of radon daughter exposure are discussed. A proposal is made for the use of case control studies of lung cancer to assess the relative importance of smoking, occupational and domestic exposure to radon daughters

  14. Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States.

    Science.gov (United States)

    Xiong, Youyou; Krogmann, Uta; Mainelis, Gediminas; Rodenburg, Lisa A; Andrews, Clinton J

    2015-01-01

    Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should

  15. A proposed UAV for indoor patient care.

    Science.gov (United States)

    Todd, Catherine; Watfa, Mohamed; El Mouden, Yassine; Sahir, Sana; Ali, Afrah; Niavarani, Ali; Lutfi, Aoun; Copiaco, Abigail; Agarwal, Vaibhavi; Afsari, Kiyan; Johnathon, Chris; Okafor, Onyeka; Ayad, Marina

    2015-09-10

    Indoor flight, obstacle avoidance and client-server communication of an Unmanned Aerial Vehicle (UAV) raises several unique research challenges. This paper examines current methods and associated technologies adapted within the literature toward autonomous UAV flight, for consideration in a proposed system for indoor healthcare administration with a quadcopter. We introduce Healthbuddy, a unique research initiative towards overcoming challenges associated with indoor navigation, collision detection and avoidance, stability, wireless drone-server communications and automated decision support for patient care in a GPS-denied environment. To address the identified research deficits, a drone-based solution is presented. The solution is preliminary as we develop and refine the suggested algorithms and hardware system to achieve the research objectives.

  16. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-05-01

    Full Text Available The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ of the built environment. A first version of this smart object, built following a do-it-yourself (DIY approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ, by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ, indoor lighting quality (ILQ and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  17. Relationships of outdoor and indoor ultrafine particles at residences downwind of a major international border crossing in Buffalo, NY.

    Science.gov (United States)

    McAuley, T R; Fisher, R; Zhou, X; Jaques, P A; Ferro, A R

    2010-08-01

    During winter 2006, indoor and outdoor ultrafine particle (UFP) size distribution measurements for particles with diameters from 5.6 to 165 nm were taken at five homes in a neighborhood directly adjacent to the Peace Bridge Complex (PBC), a major international border crossing connecting Buffalo, New York to Fort Erie, Ontario. Monitoring with 1-s time resolution was conducted for several hours at each home. Participants were instructed to keep all external windows and doors closed and to refrain from cooking, smoking, or other activity that may result in elevating the indoor UFP number concentration. Although the construction and age for the homes were similar, indoor-to-outdoor comparisons indicate that particle infiltration rates varied substantially. Overall, particle concentrations indoors were lower and less variable than particle concentrations outdoors, with average indoor-outdoor ratios ranging from 0.1 to 0.5 (mean 0.34) for particles between 5.6 and 165 nm in diameter. With no indoor sources, the average indoor-outdoor ratios were lowest (0.2) for 20-nm particles, higher (0.3) for particles <10 nm, and highest (0.5) for particles 70-165 nm. This study provides insight into the penetration of UFP into homes and the resulting change in particle size distributions as particles move indoors near a major diesel traffic source. Although people spend most of their time in their homes, exposure estimates for epidemiological studies are generally determined using ambient concentrations. The findings of this study will contribute to improved size-resolved UFP exposure estimates for near roadway exposure assessments and epidemiological studies.

  18. Seasonal and Spatial Variations of Indoor Pollen in a Hospital

    Directory of Open Access Journals (Sweden)

    Santiago Fernández-Rodríguez

    2009-12-01

    Full Text Available The airborne indoor pollen in a hospital of Badajoz (Spain was monitored over two years using a personal Burkard sampler. The air was sampled in four places indoors—one closed room and one open ward on each of the ground and the third floors—and one place outdoors at the entrance to the hospital. The results were compared with data from a continuous volumetric sampler. While 32 pollen types were identified, nearly 75% of the total counts were represented by just five of them. These were: Quercus, Cupressaceae, Poaceae, Olea, and Plantago. The average indoor concentration was 25.2 grains/m3, and the average indoor/outdoor ratio was 0.27. A strong seasonal pattern was found, with the highest levels in spring and winter, and the indoor concentrations were correlated with the outdoor one. Indoor air movement led to great homogeneity in the airborne pollen presence: the indoor results were not influenced by whether or not the room was isolated, the floor level, or the number of people in or transiting the site during sampling. The presence of ornamental vegetation in the area surrounding the building affected the indoor counts directly as sources of the pollen.

  19. Indoor air pollution from gas cooking and infant neurodevelopment.

    Science.gov (United States)

    Vrijheid, Martine; Martinez, David; Aguilera, Inma; Bustamante, Mariona; Ballester, Ferran; Estarlich, Marisa; Fernandez-Somoano, Ana; Guxens, Mònica; Lertxundi, Nerea; Martinez, M Dolores; Tardon, Adonina; Sunyer, Jordi

    2012-01-01

    Gas cooking is a main source of indoor air pollutants, including nitrogen dioxide and particles. Because concerns are emerging for neurodevelopmental effects of air pollutants, we examined the relationship between indoor gas cooking during pregnancy and infant neurodevelopment. Pregnant mothers were recruited between 2004 and 2008 to a prospective birth cohort study (INfancia y Medio Ambiente) in Spain during the first trimester of pregnancy. Third-trimester questionnaires collected information about the use of gas appliances at home. At age 11 to 22 months, children were assessed for mental development using the Bayley Scales of Infant Development. Linear regression models examined the association of gas cooking and standardized mental development scores (n = 1887 mother-child pairs). Gas cookers were present in 44% of homes. Gas cooking was related to a small decrease in the mental development score compared with use of other cookers (-2.5 points [95% confidence interval = -4.0 to -0.9]) independent of social class, maternal education, and other measured potential confounders. This decrease was strongest in children tested after the age of 14 months (-3.1 points [-5.1 to -1.1]) and when gas cooking was combined with less frequent use of an extractor fan. The negative association with gas cooking was relatively consistent across strata defined by social class, education, and other covariates. This study suggests a small adverse effect of indoor air pollution from gas cookers on the mental development of young children.

  20. [Indoor dust as a pathway of human exposure to polybrominated diphenyl ethers (PBDEs)].

    Science.gov (United States)

    Góralczyk, Katarzyna; Struciński, Paweł; Hernik, Agnieszka; Czaja, Katarzyna; Korcz, Wojciech; Minorczyk, Maria; Ludwicki, Jan K

    2012-01-01

    The brominated diphenyl ethers (PBDEs) belong to a class of synthetic, additive brominated flame retardants (BFRs). PBDEs are used to reduce the flammability of commercial and household products such as textiles, various plastic polymers, furnishing foam, and electronic equipment. People spend a large percentage of their life-time indoors at home, in offices and cars, etc, providing many opportunities for lengthy exposure to PBDEs from residential settings and commercial products in an indoor environment. In recent time, the foodstuffs, mainly food of animal origin, have been indicated as the main pathway of human exposure to PBDEs. However, many studies have shown that the indoor environment, mainly indoor dust, can be also a significant source of exposure to PBDEs, especially for younger children (toddlers) because of their behavioral patterns, eg. putting fingers, toys, and other items in their mouth. Numerous studies show that the median intakes of PBDEs via dust for adult range from 1.41 to 277 ng x day(-1) is lower than that via food which range from 135 to 333 ng x day-', while the median intake of these compounds via indoor dust for children range from 101 to 404 ng x day(-1) is much higher than via food: 77-190 ng x day(-1). The congener pattern observed in the indoor dust is different to that found in food. The indoor dust is dominated by the congener BDE-209 vs. food where the most dominated congeners are BDE-47 and BDE-99. Human exposure to PBDEs and other brominated flame retardants (BFRs) is widely widespread throughout the world and it depends on a country range of usage, production and legislation concerning these chemicals as well as a citizen's behavior. Generally, human exposure has been found higher in North America than in Europe and Asia. Within European countries the significant highest concentrations in dust have been found in the United Kingdom. It should be noted that many uncertainty factors such as personal habits, dietary preferences