WorldWideScience

Sample records for nucleaires mesures par

  1. Differential measurement of the earth's magnetic field by nuclear magnetic resonance; Mesure differentielle du champ magnetique terrestre par resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Robach, F [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1967-07-01

    MNR transducers using proton dynamic polarisation allows to convert into a phase measurement any variation of the earth magnetic field. There exist several versions of the instrument corresponding to various models of MNR transducers, which the author analyses in detail, devoting an important place to influence of their alignment with respect to the earth's magnetic field. The sensibility obtained is of one hundredth of a gamma over a bandwidth of (0-0,1 Hz). - This instrument is designed for measuring field gradients in airborne magnetic surveying, for detecting nearly magnetic anomalies, and for distinguishing between nearly and distant magnetic phenomena. (author) [French] L'emploi de capteurs, bases sur la resonance magnetique nucleaire des protons en presence de polarisation dynamique, permet de traduire une difference de champ magnetique terrestre en une mesure de phase. L'appareil existe sous plusieurs versions avec des capteurs de modeles differents dont l'auteur fait une analyse detaillee en accordant une part importante a l'influence de l'orientation des capteurs par rapport au champ magnetique terrestre. La sensibilite est de 1/100 {gamma} pour une bande passante de (0 - 0,1 Hz). Cet appareil s'applique a la mesure du gradient en prospection magnetique aeroportee, a la detection d'anomalies magnetiques proches, a la differentiation d'effets magnetiques proches et lointains. (auteur)

  2. Study of some continuous spectra produced by nuclear reactions with light nuclei; Etude de quelques spectres continus produits par reactions nucleaires avec des noyaux legers

    Energy Technology Data Exchange (ETDEWEB)

    Marquez, L

    1966-07-01

    The continuous spectra coming from several nuclear reactions with light nuclei were measured. The spectra can be explained by a two-step reaction mechanism; however, the reactions produced by {sup 6}Li are different. A mechanism was proposed to explain their spectra based on the following assumptions: {sup 6}Li makes a nuclear molecule with the target which subsequently breaks up in such a way that an {alpha} particle comes out with the kinetic energy that it has in the molecule. The calculated spectra and those measured are in good agreement. (author) [French] Nous avons mesure les spectres continus produits dans plusieurs reactions nucleaires avec des noyaux legers. A l'exception des spectres produits par {sup 6}Li, on a trouve qu'on pouvait expliquer ces spectres par le mecanisme des reactions en deux etapes. Nous avons propose un mecanisme pour expliquer les spectres produits par {sup 6}Li. On suppose que {sup 6}Li forme une molecule nucleaire avec la cible qui eclate ensuite de facon telle qu'une particule alpha de la molecule sort avec l'energie cinetique de son mouvement propre dans la molecule. Les spectres calcules avec ces hypotheses et les spectres mesures sont en bon accord. (auteur)

  3. An absolute nuclear magnetic resonance magnetometer; Magnetometre absolu a resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Salvi, A [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-10-15

    After an introduction in which the various work undertaken since the discovery of nuclear magnetic resonance is rapidly reviewed, the author describes briefly In the first chapter three types of NMR magnetometers, giving the advantages and disadvantages of each of them and deducing from this the design of the apparatus having the greatest number of qualities Chapter II is devoted to the crossed coil nuclear oscillator which operates continuously over a wide range (800 gamma). To avoid an error due to a carrying over the frequency, the measurement is carried out using bands of 1000 {gamma}. Chapter III deals with frequency measurements. The author describes an original arrangement which makes possible the frequency-field conversion with an accuracy of {+-} 5 x 10{sup -6}, and the differential measurement between two nuclear oscillators. The report finishes with a conclusion and a few recordings. (author) [French] Apres une introduction rappelant les divers travaux effectues en resonance magnetique nucleaire depuis sa mise en evidence, l'auteur decrit sommairement dans le premier chapitre trois types de magnetometre a R.M.N. enumerant les avantages et les inconvenients de chacun a partir desquels il projet, l'appareillage reunissant le maximum de qualites. Le chapitre II est consacre a l'oscillateur nucleaire a bobines croisees permettant un fonctionnement continu dons une large plage (800 gamma). Pour eviter une erreur due a l'entrainement de frequence, la mesure s'effectue par bandes de 1000 {gamma} chacune. Le chapitre III traite la mesure de frequence. L'auteur expose un montage original permettant la traduction frequence-champ avec une precision egale a {+-} 5.10{sup -6}, et la mesure differentielle entre deux oscillateurs nucleaires. Une conclusion et quelques enregistrements terminent ce travail. (auteur)

  4. Technique of nuclear reactors controls; Technique des controles des reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-12-15

    This report deal about 'Techniques of control of the nuclear reactors' in the goal to achieve the control of natural uranium reactors and especially the one of Saclay. This work is mainly about the measurement into nuclear parameters and go further in the measurement of thermodynamic variables,etc... putting in relief the new features required on behalf of the detectors because of their use in the thermal neutrons flux. In the domain of nuclear measurement, we indicate the realizations and the results obtained with thermal neutron detectors and for the measurement of ionizations currents. We also treat the technical problem of the start-up of a reactor and of the reactivity measurement. We give the necessary details for the comprehension of all essential diagrams and plans put on, in particular, for the reactor of Saclay. (author) [French] Nous avons aborde le probleme de la ''Technique du Controle des reacteurs nucleaires'' dans le but de realiser le controle du reacteur de Saclay. C'est ainsi que nous avons ete amene a etudier le probleme dans son ensemble, tel qu'il se pose pour tout reacteur a uranium naturel. Ce travail traite principalement du domaine des mesures a caractere nucleaire et s'etend dans le domaine des mesures thermodynamque de niveaux, etc... mettant en relief les caracteristiques nouvelles exigees de la part des detecteurs du fait de leur utilisation dans le flux de neutrons thermiques. Dans le domaine de mesures nucleaires, nous indiquons principalement les realisations et les resultats obtenus pour les detecteurs de neutrons thermiques et pour la mesure de courants d'ionisations. Nous traitons egalement du probleme technique du demarrage d'un reacteur et du probleme de la mesure de la reactivite. Nous donnons les details necessaires a la comrehension de tous les schemas et plans de cablages essentiels mis au point, en particulier, pour le reacteur de Saclay. (auteur)

  5. A study of the fluorescence of the rare gases excited by nuclear particles. Use of the principle for the detection of nuclear radiation by scintillation; Etude de la fluorescence des gaz rares excites par des particules nucleaires. Utilisation pour la detection des rayonnements nucleaires par scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-12-15

    composantes, l'une tres breve due a la desexcitation directe du gaz rare, l'autre relativement plus lente, due au transfert d'energie sur les impuretes. La mesure des durees de vie des etats excites a confirme l'hypothese precedente, la partie breve de l'impulsion est extremement courte: inferieure a 2,25.10{sup -9} s dans le cas du xenon, la partie plus lente a une duree qui depend etroitement de la concentration d'azote, l'azote etant l'impurete dont le role est preponderant dans tous les cas. L'etude des gaz rares soumis a un champ electrique a permis de montrer que la quantite de lumiere produite par une particule {alpha} peut etre multipliee (par 60 dans un champ de 600 V/cm par exemple) ce qui correspond a un rendement de luminescence superieur a celui de INa TI. Dans la deuxieme partie on a etudie les caracteristiques des gaz rares comme scintillateurs, la plus importante est l'absence de saturation de la fluorescence lorsque la densite d'excitation transmise au gaz devient tres grande. Ceci joint au temps de scintillation tres court a permis d'etudier un certain nombre d'applications a la physique nucleaire (mesure d'energie des particules lourdes, etude cinetique des reacteurs nucleaires, spectroscopie des neutrons...). (auteur)

  6. Statistical pulses generator. Application to nuclear instrumentation (1962); Generateur d'impulsions aleatoires. Application a l'instrumentation nucleaire (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Beranger, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    This report describes a random pulses generator adapted to nuclear instrumentation. After a short survey on the statistical nature of electronic signals, the different ways for generating pulses with a Poisson's time-distribution are studied. The final generator built from a gaseous thyratron in a magnetic field is then described. Several tests are indicated : counting-rate stability, Pearson's criterion, distribution of time-intervals. Applications of the generator in 'whole testing' of nuclear instrumentation are then indicated for sealers, dead time measurements, time analyzers. In this application, pulse-height spectrums have been made by Poissonian sampling of a recurrent or random low-frequency signal. (author) [French] Cette etude decrit un generateur d'impulsions aleatoires et ses applications a l'instrumentation nucleaire. Apres un bref rappel sur la nature statistique des signaux en electronique nucleaire, sont passes en revue les principaux moyens d'obtenir des impulsions distribuees en temps suivant une loi de Poisson. Le generateur utilisant un thyratron a gaz dans un champ magnetique est ensuite decrit; diverses methodes de test sont appliquees (stabilite du taux de comptage, criterium de Pearson, spectre des intervalles ds temps). Les applications du generateur a l'electronique nucleaire dans le domaine des 'essais globaux' sont indiques: test des echelles de comptage et mesure des temps morts, test des analyseurs en temps apres division du taux de comptage par une puissance de deux, test des analyseurs multicanaux en amplitude. Pour cette derniere application, on a realise des spectres d'amplitudes suivant une loi connue, par echantillonnage poissonien d'un signal basse frequence recurrent ou aleatoire. (auteur)

  7. Mesures de teneurs en eau volumique et massique sur du sable

    OpenAIRE

    FAUCHARD, Cyrille; GUILBERT, Vincent; SAGNARD, Florence; FROUMENTIN, Michel

    2009-01-01

    Usuellement, la mesure par séchage en étuve et la mesure de la masse volumique humide par méthode nucléaire permettent de relier la teneur en eau massique à la teneur en eau volumique. La méthodologie étudiée ici propose d'associer à la mesure de la masse volumique humide une estimation de la teneur en eau volumique par des méthodes électromagnétiques via la mesure de la permittivité diélectrique apparente du sol. Ce paramètre physique peut être relié à la teneur en eau volumique par une loi ...

  8. French research in the field of nuclear agronomy; Les recherches francaises en agronomie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Guerin De Montgareuil, P [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1964-07-01

    , industrial firms, university laboratories scientific institutes. The role of the Commissariat a l'Energie Atomique is defined: on the one hand it supplies information and support, and on the other hand it takes charge of specifically nuclear aspects of the work. Its part in the field has recently found expression in the creation, within the Biology Department, of a Radio-agronomy Section; its objective are described,, as well as the, means placed att its disposal at the Centre d'etudes Nucleaires, Cadarache. (author) [French] On propose un bilan des travaux les plus significatifs effectues en France depuis la deuxieme conference internationale en matiere d'agronomie nucleaire et qui vont d'une recherche apparemment desinteressee a l'application la plus directe. Une telle differenciation recouvre de moins en moins, au fur et a mesure de l'evolution des programmes, la distinction qui est faite dans l'expose entre l'action biologique des rayonnements et les autres emplois des techniques nucleaires. C'est ainsi que les recherches do radiogenetique agricole sont poursuivies dans deux directions: d'un point de vue theorique et methodologique avec l'etude comparative de l'action des divers types de rayonnements, l'influence du debit de dose et de la temperature, l'action des agents mutagenes chimiques, la production de chimeres sous irradiation gamma; et d'autre part, sous un aspect pratique aboutissant a la creation de varietes nouvelles plus resistantes ou plus precoces (riz, mil, arachide). Les problemes de destruction des insectes (eradication) et de conservation des denrees sous irradiation se trouvent egalement abordes par des voies et avec des objectifs tres divers. A la demarche globale representee par une irradiation pure et simple (grains humides, pommes de terre...) sont parfois associees des etudes souvent originales, d'ordre biochimique ou microbiologique (par exemple: alteration de l'amidon, metabolisme glucidique des tubercules irradies, radioresistance des levures

  9. Contribution to the study of the evolution of radiation induced He in Be O; Etudes sur l'evolution de l'helium produit par reactions nucleaires dans l'oxyde de beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Bareau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-11-15

    The purpose of this work in-pile investigation of He formed by (n, 2n) and (n, {alpha}) nuclear reactions, released from irradiated BeO, in the temperature range 1000 - 1350 deg. C. The experimental results show that, for an instantaneous neutron fast flux of 10{sup 13} n cm{sup -2} sec{sup -1}, an equilibrium is attempted, after several days, for a part lower than 20 per cent of the quantity of He formed, theoretically calculated from the neutron cross sections of nuclear reactions, and from the analytical form of the neutron fast flux, releases from the solid. The validity of the values of calculated helium and the gas chromatographic analytical method are also verified by dissolution of the BeO pellets in cryolite. A new fast neutron flux measuring method may be so defined. The discussion of the experimental results enables to establish that the processus of He release is characterized by two phenomena: the first one which controls the release of He atoms out of the solid and the second which reveals a capture processus, connected to the irradiation and probably due to the vacancies induced in the lattice. (author) [French] On etudie en pile le degagement de l'helium forme par reactions nucleaires (n, 2 n) et (n, {alpha}) dans l'oxyde de beryllium irradie entre 1000 et 1350 deg. C. Les resultats experimentaux montrant que, pour un flux rapide instantane de 10{sup 13} n{sub r} cm{sup -2} s{sup -1}, on aboutit, au bout de quelques jours, a un etat d'equilibre pour lequel une partie, inferieure a 20 pour cent de la quantite d'helium forme, calculee theoriquement a partir des sections efficaces des reactions nucleaires et de la forme analytique du flux rapide, s'echappe du solide. On verifie egalement par dissolution des echantillons de BeO dans la cryolithe la validite du calcul de l'helium et de la methode de dosage par chromatographie en phase gazeuse. On peut ainsi definir une methode nouvelle de mesure des flux rapides. La discussion des resultats experimentaux

  10. Study of the chimney produced by an underground nuclear explosion; Etude de la cheminee creee par une explosion nucleaire souterraine

    Energy Technology Data Exchange (ETDEWEB)

    Derlich, S [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    Underground nuclear explosions lead to the formation of a cavity which is roughly of spherical shape. The roof of this cavity is unstable and collapses in most cases, leading to the formation of a chimney. The height and the diameter depend on the energy of the charge and on the nature of the surroundings. The chronology of the various stages can be determined by seismic observations. The interior of the chimney is filled, either partially or completely, with rubble earth. This phenomenon is of great importance as far as the use of nuclear explosions for industrial applications is concerned. (author) [French] Les explosions nucleaires souterraines creent une cavite de forme grossierement spherique. La voute de cette cavite est instable et s'effondre dans la plupart des cas, donnant lieu a la formation d'une cheminee. La hauteur et le diametre sont fonction de l'energie du tir et de la nature du milieu. La chronologie des evenements peut etre determinee par des observations seismiques. L'interieur des cheminees est occupe, en partie ou en totalite, par des eboulis. Ce phenomene presente un grand interet pour l'utilisation des explosions nucleaires a des fins industrielles. (auteur)

  11. The development of an electrically compensated differential calorimeter for the measurement of in-pile heat evolution (1962); Etude et realisation d'un calorimetre differentiel a compensation electrique pour la mesure des echaufpements en pile (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Ayela, F; Derrien, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    It has been possible with the calorimeter of which we give the principle and details in the present report, to determine the calorific power produced by nuclear radiation in a given sample using simple electrical measurement. It also renders unnecessary all absolute measurements of temperature, all possible calibration, and the use of the thermal or thermoelectric constants of the constituent elements. The possible uses of the apparatus are fairly varied, as shown by the first in-pile experiments which we have carried out and for which we give results. (authors) [French] Le calorimetre, dont nous decrivons le principe et les details dans le present rapport, nous permet de determiner, par de simples mesures electriques, la puissance calorifique liberee par les rayonnements nucleaires dans un echantillon donne. Il nous affranchit aussi, de toute mesure absolue de temperature, de tout etalonnage prealable, et de l'utilisation des constantes thermiques ou thermoelectriques de ses elements constitutifs. Les possibilites d'emploi de l'appareil sont assez variees comme nous le montrent les premiers essais que nous avons effectues en pile et dont nous donnons les resultats. (auteurs)

  12. French research in the field of nuclear agronomy; Les recherches francaises en agronomie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Guerin De Montgareuil, P. [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1964-07-01

    , industrial firms, university laboratories scientific institutes. The role of the Commissariat a l'Energie Atomique is defined: on the one hand it supplies information and support, and on the other hand it takes charge of specifically nuclear aspects of the work. Its part in the field has recently found expression in the creation, within the Biology Department, of a Radio-agronomy Section; its objective are described,, as well as the, means placed att its disposal at the Centre d'etudes Nucleaires, Cadarache. (author) [French] On propose un bilan des travaux les plus significatifs effectues en France depuis la deuxieme conference internationale en matiere d'agronomie nucleaire et qui vont d'une recherche apparemment desinteressee a l'application la plus directe. Une telle differenciation recouvre de moins en moins, au fur et a mesure de l'evolution des programmes, la distinction qui est faite dans l'expose entre l'action biologique des rayonnements et les autres emplois des techniques nucleaires. C'est ainsi que les recherches do radiogenetique agricole sont poursuivies dans deux directions: d'un point de vue theorique et methodologique avec l'etude comparative de l'action des divers types de rayonnements, l'influence du debit de dose et de la temperature, l'action des agents mutagenes chimiques, la production de chimeres sous irradiation gamma; et d'autre part, sous un aspect pratique aboutissant a la creation de varietes nouvelles plus resistantes ou plus precoces (riz, mil, arachide). Les problemes de destruction des insectes (eradication) et de conservation des denrees sous irradiation se trouvent egalement abordes par des voies et avec des objectifs tres divers. A la demarche globale representee par une irradiation pure et simple (grains humides, pommes de terre...) sont parfois associees des etudes souvent originales, d'ordre biochimique ou microbiologique (par exemple: alteration de l

  13. Measurements of fission cross-sections and of neutron production rates; Mesures de sections efficaces de fission et du nombre de neutrons prompts emis par fission

    Energy Technology Data Exchange (ETDEWEB)

    Billaud, P; Clair, C; Gaudin, M; Genin, R; Joly, R; Leroy, J L; Michaudon, A; Ouvry, J; Signarbieux, C; Vendryes, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    a) Measurements of neutron induced fission cross-sections in the low energy region. The variation of the fission cross sections of several fissile isotopes has been measured and analysed, for neutron energies below 0,025 eV. The monochromator was a crystal spectrometer used in conjunction with a mechanical velocity selector removing higher order Bragg reflections. The fissile material was laid down on the plates of a fission chamber by painting technic. An ionization chamber, having its plates coated with thin {sup 10}B layers, was used as the neutron flux monitor. b) Measurement of the fission cross section of {sup 235}U. We intend to measure the variation of the neutron induced fission cross section of {sup 235}U over the neutron energy range from 1 keV by the time of flight method. The neutron source is the uranium target of a pulsed 28 MeV electron linear accelerator. The detector is a large fission chamber, with parallel plates, containing about 10 g of {sup 235}U (20 deposits of 25 cm diameter). The relative fission data were corrected for the neutron spectrum measured with a set of BF{sub 3} proportional counters. c) Mean number {nu} of neutrons emitted in neutron induced fission. We measured the value of {nu} for several fissile isotopes in the case of fission induced by 14 MeV neutrons. The 14 MeV neutrons were produced by D (t, n) {alpha} reaction by means of a 300 kV Cockcroft Walton generator. (author)Fren. [French] a) Mesures de sectionficaces de fission a basse energie. Nous avons mesure et analyse la variation de la section efficace de fission de divers isotopes fissiles pour des neutrons d'energie inferieure a 0,025 eV. Le monochromateur est constitue par un spectrometre a cristal auquel est associe un selecteur mecanique destine a eliminer les diffractions de Bragg d'ordre superieur au premier. Le materiau fissile est contenu dans une chambre a fission sous forme de depots realises par peinture; une chambre d'ionisation a depots minces de B{sub 10

  14. Contribution to the study of the evolution of radiation induced He in Be O; Etudes sur l'evolution de l'helium produit par reactions nucleaires dans l'oxyde de beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Bareau, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-11-15

    The purpose of this work in-pile investigation of He formed by (n, 2n) and (n, {alpha}) nuclear reactions, released from irradiated BeO, in the temperature range 1000 - 1350 deg. C. The experimental results show that, for an instantaneous neutron fast flux of 10{sup 13} n cm{sup -2} sec{sup -1}, an equilibrium is attempted, after several days, for a part lower than 20 per cent of the quantity of He formed, theoretically calculated from the neutron cross sections of nuclear reactions, and from the analytical form of the neutron fast flux, releases from the solid. The validity of the values of calculated helium and the gas chromatographic analytical method are also verified by dissolution of the BeO pellets in cryolite. A new fast neutron flux measuring method may be so defined. The discussion of the experimental results enables to establish that the processus of He release is characterized by two phenomena: the first one which controls the release of He atoms out of the solid and the second which reveals a capture processus, connected to the irradiation and probably due to the vacancies induced in the lattice. (author) [French] On etudie en pile le degagement de l'helium forme par reactions nucleaires (n, 2 n) et (n, {alpha}) dans l'oxyde de beryllium irradie entre 1000 et 1350 deg. C. Les resultats experimentaux montrant que, pour un flux rapide instantane de 10{sup 13} n{sub r} cm{sup -2} s{sup -1}, on aboutit, au bout de quelques jours, a un etat d'equilibre pour lequel une partie, inferieure a 20 pour cent de la quantite d'helium forme, calculee theoriquement a partir des sections efficaces des reactions nucleaires et de la forme analytique du flux rapide, s'echappe du solide. On verifie egalement par dissolution des echantillons de BeO dans la cryolithe la validite du calcul de l'helium et de la methode de dosage par chromatographie en phase gazeuse. On peut ainsi definir une methode nouvelle de mesure des flux rapides. La

  15. La mesure de pluie par radar : du calibrage par des pluviomètres vers l'interprétation physique des images

    OpenAIRE

    ANDRIEU, H

    2002-01-01

    Cet article retrace l'évolution des méthodes de traitement des images radar pour la mesure des précipitations. Les études ont tout donné la priorité au calibrage des images radar par des données pluviométriques de façon à bénéficier des avantages supposés de chaque capteur : représentativité ponctuelle du pluviomètre, continuité spatiale de l'image radar. Bien que positifs, les résultats obtenus ont mis en évidence la nécessité d'une détection et d'une correction des principales sources d'err...

  16. Results of concentration measurements of artificial radioactive aerosols in the lower atmosphere; Resultats des mesures de concentration, dans la basse atmosphere, des aerosols radioactifs artificiels

    Energy Technology Data Exchange (ETDEWEB)

    Ardouin, B; Jehanno, C; Labeyrie, J; Lambert, G; Tanaevsky, O; Vassy, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    This report gives the results of the measurements of artificial gross-{beta}-radioactivity in aerosols in the lower atmosphere; these measurements have been made by the Electronic Physics Service of the Electronic Department, and by the Atmospheric Physics Laboratory of the Paris Science Faculty. The measurements were begun in September 1956 and were continued in an increasing number of stations both in France and in the rest of the world. The present report deals with the period up to the end of august 1961, that is up to the end of the nuclear moratorium. After recalling the constitution and the properties of radioactive aerosols present in the atmosphere, the authors describe the measurement methods, estimate their accuracy and discuss various aspects of the results. (authors) [French] Ce rapport contient les resultats des mesures de radioactivite {beta} globale d'origine artificielle des aerosols dans la basse atmosphere, effectuees conjointement par le Service d'Electronique Physique du Departement d'Electronique et le Laboratoire de Physique de l'Atmosphere de la Faculte des Sciences de Paris. Les mesures ont commence en septembre 1956 et ont ete poursuivies dans un nombre croissant de stations, tant en France que dans le reste du monde. Le present rapport s'arrete a la fin aout 1961, c'est-a-dire au moment de la reprise des essais nucleaires. Apres avoir rappele la constitution et les proprietes des aerosols radioactifs presents dans l'atmosphere, les auteurs indiquent les methodes de mesure utilisees, evaluent leur precision et discutent les differents aspects des resultats de leurs mesures. (auteurs)

  17. Possibility of gas flow measurements using ionization produced by radioactive sources. Performance obtained using continuous and pulsed ionization; Etude des possibilites de mesure des debits gazeux par l'ionisation creee au moyen de sources radioactives performances obtenues par ionisation continue et par ionisation pulsee

    Energy Technology Data Exchange (ETDEWEB)

    Toudoire, B. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Two methods for measuring gas flow have been studied, based on the ionization of the fluid by a radioactive source. In the first one, called the continuous method, use is made of the relationship between the flow and the ionic density at a point situated down-stream from the ionizing source. In the second method, called 'pulsed', the time for a burst of ions to pass between two points in the circuit is measured. An attempt has been made to predict and to justify theoretically the experimental results, and to determine to what extent these methods can provide absolute measurements or measurements requiring a calibration using known gas flows. These methods are characterized by the absence of moving parts or of parts under reduced pressure and can yield results with an accuracy of between a few per cent to a few tenths of a per cent. The information, provided in either analog or digital form, can be adapted for use in servo-mechanisms or automatic systems. Two applications of an industrial type are described; they concern gas-flow measurements in a railway braking circuit, and in tubes of 20 and 30 cm diameter. (author) [French] Deux methodes de mesure de debit gazeux ont ete etudiees, basees sur l'ionisation du fluide par une source radioactive. Dans la premiere, dite continue, on exploite la relation existant entre le debit et la densite ionique en un point situe a l'aval de la source ionisante. Dans la seconde, dite pulsee, on mesure le temps de transit de bouffees d'ions entre deux points de la conduite. On s'est efforce de prevoir et de justifier par la theorie les resultats experimentaux, et de preciser dans quelle mesure ces methodes peuvent fournir des mesures absolues ou necessitent un etalonnage a partir de debits connus. Caracterisees par l'absence d'organe mobile ou deprimogene, ces methodes sont susceptibles d'une precision de quelques pour-cent a quelques pour-mille. L'information, fournie sous forme

  18. Possibility of gas flow measurements using ionization produced by radioactive sources. Performance obtained using continuous and pulsed ionization; Etude des possibilites de mesure des debits gazeux par l'ionisation creee au moyen de sources radioactives performances obtenues par ionisation continue et par ionisation pulsee

    Energy Technology Data Exchange (ETDEWEB)

    Toudoire, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Two methods for measuring gas flow have been studied, based on the ionization of the fluid by a radioactive source. In the first one, called the continuous method, use is made of the relationship between the flow and the ionic density at a point situated down-stream from the ionizing source. In the second method, called 'pulsed', the time for a burst of ions to pass between two points in the circuit is measured. An attempt has been made to predict and to justify theoretically the experimental results, and to determine to what extent these methods can provide absolute measurements or measurements requiring a calibration using known gas flows. These methods are characterized by the absence of moving parts or of parts under reduced pressure and can yield results with an accuracy of between a few per cent to a few tenths of a per cent. The information, provided in either analog or digital form, can be adapted for use in servo-mechanisms or automatic systems. Two applications of an industrial type are described; they concern gas-flow measurements in a railway braking circuit, and in tubes of 20 and 30 cm diameter. (author) [French] Deux methodes de mesure de debit gazeux ont ete etudiees, basees sur l'ionisation du fluide par une source radioactive. Dans la premiere, dite continue, on exploite la relation existant entre le debit et la densite ionique en un point situe a l'aval de la source ionisante. Dans la seconde, dite pulsee, on mesure le temps de transit de bouffees d'ions entre deux points de la conduite. On s'est efforce de prevoir et de justifier par la theorie les resultats experimentaux, et de preciser dans quelle mesure ces methodes peuvent fournir des mesures absolues ou necessitent un etalonnage a partir de debits connus. Caracterisees par l'absence d'organe mobile ou deprimogene, ces methodes sont susceptibles d'une precision de quelques pour-cent a quelques pour-mille. L'information, fournie sous forme analogique ou numerique, se prete a la realisation de

  19. La productivité et sa mesure en France (1944-1955)

    OpenAIRE

    Boulat, Régis

    2009-01-01

    Après la Deuxième Guerre mondiale, grâce à Jean Fourastié et aux modernisateurs du Plan, la productivité est reconnue par les élites et par l'opinion publique française comme « la clef » de la connaissance économique et le moteur de la croissance. Alors que la IVe République institutionnalise une politique d'accroissement de la prductivité dans le cadre d'un programme franco-américain de modernisation, la mesure de la productivité se perfectionne lentement grâce à l'affinement des mesures de ...

  20. Applications of electrical resistivity measurements to research into the purification of uranium using floating molten zone by electronic bombardment; Applications des mesures de resistivite electrique a l'etude de la purification de l'uranium par fusion de zone flottante par bombardement electronique

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, J L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-02-01

    un examen micrographique, des mesures de microdurete et des essais de recristallisation secondaire, a permis d'apprecier le nouveau degre de purete de l'uranium obtenu. L'examen de ce degre de purete a ete poursuivi par des mesures de resistivite electrique a 20 deg. K. Mais on a du tenir compte dans l'interpretation de ces mesures, de l'anisotropie de resistivite de l'uranium {alpha} a 20 deg. C et de l'influence de l'etat structural sur la resistivite residuelle. Ces mesures ont conduit, en determinant les resistivires de monocristaux d'uranium {alpha}, a distinguer les resistivites principales suivant les axes [100] et [010]. (auteur)

  1. Measurement and analysis of high energy radiation through activation detectors. Application in dosimetry; Sur la mesure et l'analyse des rayonnements de haute energie par detecteurs a activation. Application a la dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Sklavenitis, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-10-15

    reactions nucleaires a tres haute energie est realisee ainsi que la mesure et le calcul des sections efficaces d'un certain nombre de reactions, comme la reaction {sup 11}B (p,n) {sup 11}C entre 150 et 3000 MeV et la reaction {sup 34}S (p,2pn) {sup 32}P entre 50 et 3000 MeV. La deuxieme partie est relative a l'application de l'analyse des fluences dans un fantome equivalent aux tissus irradie par des protons de 3 GeV. Cette analyse est suffisamment detaillee pour permettre de reconstituer les doses absorbees, les equivalents de dose et, sous reserve d'une meilleure connaissance de la dose due aux particules lourdes, les facteurs de qualite. Elle a permis, par ailleurs, de suivre l'evolution des differentes donnees dosimetriques en fonction de la profondeur dans le fantome et d'effectuer une verification des calculs deja faits par d'autres chercheurs. La comparaison des doses mesurees et des activites correspondantes de certains detecteurs a revele une qualite de ces derniers pouvant eventuellement conduire a la mise au point d'un detecteur qui donnerait directement la dose absorbee ou meme l'equivalent de dose par simple mesure de son activite. (auteur)

  2. Physical analytical methods for uranium hexafluoride; Methodes physiques d'analyse de l'hexafluorure d'uranium

    Energy Technology Data Exchange (ETDEWEB)

    Vandenbussche, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-12-15

    Various physical methods of analysis currently used or still under investigation such as: sound analysis, vapor pressure measurements, fractional distillation, cryogenics, micro-sublimation, ultra-violet, visible and infra-red absorption spectrophotometry, nuclear magnetic resonance and mass spectrometry are reviewed. For each method, principle and applications are given, and results obtained concerning reproducibility, application limits and rapidity are discussed. (author) [French] On passe en revue les differentes methodes physiques d'analyse utilisees ou en cours d'etude actuellement: par mesure de la vitesse du son, de la pression de vapeur, par distillation fractionnee, cryometrie, microsublimation, spectrometrie d'absorption dans l'ultraviolet, le visible et l'infrarouge, par resonance magnetique nucleaire et par spectrometrie de masse. Pour chaque methode, on donne le principe et son application et on examine les resultats obtenus concernant la reproductibilite, le domaine d'application et la duree des mesures. (auteur)

  3. Neutron detection in an atomic reactor core using semi-conductors; Detection des neutrons par semi-conducteur dans un coeur de reacteur atomique

    Energy Technology Data Exchange (ETDEWEB)

    Divoux, F [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    In this paper, the first part describes the principle of nuclear particle detection by means of semiconductor diodes and the general application of these. The second part describes fabrication of the device used to estimate thermic neutron fluxes in core of a swimming pool type reactor. The useful volume (2.9 mm thickness) is in the light water moderator, between combustible elements plates. The results, principally obtained in the core of Siloette reactor at the 'Centre d'Etudes Nucleaires de Grenoble' at low power, are mentioned in the third part. Flux maps have been set and comparison between converter's products: Bore 10, Lithium 6, Uranium 235 is made. (author) [French] Dans ce rapport, une premiere partie porte sur la description du principe de detection des particules nucleaires par diodes a semi-conducteur et sur l'application generale de celles-ci. Une deuxieme partie s'attache a decrire la fabrication du materiel utilise pour evaluer les flux de neutrons thermiques dans un coeur de reacteur type pile piscine. L'espace de mesure (2,9 mm d'epaisseur) se situe entre les plaques des elements combustibles, dans le moderateur eau legere. Les resultats, obtenus principalement dans le coeur du reacteur Siloette du Centre d'Etudes Nucleaires de Grenoble aux basses puissances de fonctionnement, sont rapportes dans la troisieme partie. Des cartes de flux ont ete dressees et une comparaison est faite entre les produits 'convertisseurs' suivants: Bore 10, Lithium 6, Uranium 235. (auteur)

  4. Mesurer en réseau d'assainissement pour quoi faire ?

    OpenAIRE

    LAPLACE, Dominique; JOANNIS, Claude; GUIVARCH, Jean Yves

    2009-01-01

    La mesure de pluie, de niveau d'eau, de vitesse, de débit ou encore de pollution en réseau d'assainissement répond essentiellement à des besoins de contrôle du bon fonctionnement du système, de compréhension et d'amélioration de ces réseaux et d'information des différents acteurs impliqués. Associée à un dispositif de gestion en temps la mesure contribue à permettre de surveiller et maîtriser le fonctionnement du réseau par temps sec et par temps de pluie, et de piloter des actionneurs (pompe...

  5. Measurement and analysis of high energy radiation through activation detectors. Application in dosimetry; Sur la mesure et l'analyse des rayonnements de haute energie par detecteurs a activation. Application a la dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Sklavenitis, L. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-10-15

    detecteurs, une etude systematique des reactions nucleaires a tres haute energie est realisee ainsi que la mesure et le calcul des sections efficaces d'un certain nombre de reactions, comme la reaction {sup 11}B (p,n) {sup 11}C entre 150 et 3000 MeV et la reaction {sup 34}S (p,2pn) {sup 32}P entre 50 et 3000 MeV. La deuxieme partie est relative a l'application de l'analyse des fluences dans un fantome equivalent aux tissus irradie par des protons de 3 GeV. Cette analyse est suffisamment detaillee pour permettre de reconstituer les doses absorbees, les equivalents de dose et, sous reserve d'une meilleure connaissance de la dose due aux particules lourdes, les facteurs de qualite. Elle a permis, par ailleurs, de suivre l'evolution des differentes donnees dosimetriques en fonction de la profondeur dans le fantome et d'effectuer une verification des calculs deja faits par d'autres chercheurs. La comparaison des doses mesurees et des activites correspondantes de certains detecteurs a revele une qualite de ces derniers pouvant eventuellement conduire a la mise au point d'un detecteur qui donnerait directement la dose absorbee ou meme l'equivalent de dose par simple mesure de son activite. (auteur)

  6. Mechanics and electronics as auxiliary techniques in nuclear research and exploitation; Mecanique et electronique auxiliaires de la recherche et de l'exploitation nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre d' Etudes nucleaires de Saclay, Departement Electronique, Groupe Controle des Reacteurs (France)

    1959-07-01

    Electronics and mechanics form the basic techniques used in the field of measurement and control in nuclear physics experiments, and in nuclear machine installations. The delegate describes some instruments typical of the use of these techniques in the fields of calculation, detection, amplification and nuclear Installations. Reprint of a paper published in 'Bulletin S.F.M.' n. 25 (3. quarter 1957) [French] L'electronique et la mecanique constituent les techniques de base utilisees clans le domaine des mesures et du controle effectues dans les experiences de physique nucleaire et dans les installations des engins nucleaires. Le Conferencier decrit plusieurs appareils caracteristiques de l'emploi de ces techniques dans les domaines du calcul, des detecteurs, de l'amplification et des lnstallations nucleaires. Reproduction d'un article publie dans le 'Bulletin S.F.M.' n. 25 (3e trimestre 1957)

  7. Health problems raised by the elimination of radioactive wastes and nuclear accidents; Problemes sanitaires poses par l'elimination des dechets radioactifs et par les accidents nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Jammet, H; Mechali, D; Dousset, M [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The rapid development of nuclear energy demands an urgent solution to the health problems arising from the discharge into the environment of radioactive residues produced by nuclear installations. - To be able to evaluate the risks run by the population and to fix tolerance limits for waste discharge, it is necessary to possess an exact knowledge of the course taken by the radioelements discharged, from their source until they reach man. The incorporation of radioelements in food cycles is the first risk to take into consideration. The factors involved in all stages of this transmission must be foreseen, whether they concern physical or biological media, because of their continuity and their interdependence. Finally, socio-economic and dietetic data must be collected in order that the risks and tolerance levels estimated are based on concrete and experimental rather than theoretical knowledge. The risk of nuclear accidents in the atomic industry, although very improbable, must be taken into consideration because of the seriousness of their consequences. The health problems arise in the field of professional hygiene on the one hand and in that of public hygiene on the other. In the first field the risk is two-fold and involves irradiation and contamination. The public sphere is reduced essentially to the risk of contamination by radioactive substances accidentally released in the surrounding medium. The health studies to be conducted in this field therefore include research not only on irradiation or contamination therapeutics but also on the transfer of radioelements from the accident site to man, mainly through food cycles, in their physical and in their biological components. Studies of this kind form the basis of decisions in the health field which would have to be taken in the case of an accident. (authors) [French] Le developpement rapide de l'energie nucleaire rend urgente la solution des problemes sanitaires poses par le rejet dans le milieu ambiant des

  8. Mesure et retroaction sur un qubit multi-niveaux en electrodynamique quantique en circuit non lineair

    Science.gov (United States)

    Boissonneault, Maxime

    L'electrodynamique quantique en circuit est une architecture prometteuse pour le calcul quantique ainsi que pour etudier l'optique quantique. Dans cette architecture, on couple un ou plusieurs qubits supraconducteurs jouant le role d'atomes a un ou plusieurs resonateurs jouant le role de cavites optiques. Dans cette these, j'etudie l'interaction entre un seul qubit supraconducteur et un seul resonateur, en permettant cependant au qubit d'avoir plus de deux niveaux et au resonateur d'avoir une non-linearite Kerr. Je m'interesse particulierement a la lecture de l'etat du qubit et a son amelioration, a la retroaction du processus de mesure sur le qubit de meme qu'a l'etude des proprietes quantiques du resonateur a l'aide du qubit. J'utilise pour ce faire un modele analytique reduit que je developpe a partir de la description complete du systeme en utilisant principalement des transfprmations unitaires et une elimination adiabatique. J'utilise aussi une librairie de calcul numerique maison permettant de simuler efficacement l'evolution du systeme complet. Je compare les predictions du modele analytique reduit et les resultats de simulations numeriques a des resultats experimentaux obtenus par l'equipe de quantronique du CEASaclay. Ces resultats sont ceux d'une spectroscopie d'un qubit supraconducteur couple a un resonateur non lineaire excite. Dans un regime de faible puissance de spectroscopie le modele reduit predit correctement la position et la largeur de la raie. La position de la raie subit les decalages de Lamb et de Stark, et sa largeur est dominee par un dephasage induit par le processus de mesure. Je montre que, pour les parametres typiques de l'electrodynamique quantique en circuit, un accord quantitatif requiert un modele en reponse non lineaire du champ intra-resonateur, tel que celui developpe. Dans un regime de forte puissance de spectroscopie, des bandes laterales apparaissent et sont causees par les fluctuations quantiques du champ electromagnetique

  9. Health problems raised by the elimination of radioactive wastes and nuclear accidents; Problemes sanitaires poses par l'elimination des dechets radioactifs et par les accidents nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Jammet, H.; Mechali, D.; Dousset, M. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The rapid development of nuclear energy demands an urgent solution to the health problems arising from the discharge into the environment of radioactive residues produced by nuclear installations. - To be able to evaluate the risks run by the population and to fix tolerance limits for waste discharge, it is necessary to possess an exact knowledge of the course taken by the radioelements discharged, from their source until they reach man. The incorporation of radioelements in food cycles is the first risk to take into consideration. The factors involved in all stages of this transmission must be foreseen, whether they concern physical or biological media, because of their continuity and their interdependence. Finally, socio-economic and dietetic data must be collected in order that the risks and tolerance levels estimated are based on concrete and experimental rather than theoretical knowledge. The risk of nuclear accidents in the atomic industry, although very improbable, must be taken into consideration because of the seriousness of their consequences. The health problems arise in the field of professional hygiene on the one hand and in that of public hygiene on the other. In the first field the risk is two-fold and involves irradiation and contamination. The public sphere is reduced essentially to the risk of contamination by radioactive substances accidentally released in the surrounding medium. The health studies to be conducted in this field therefore include research not only on irradiation or contamination therapeutics but also on the transfer of radioelements from the accident site to man, mainly through food cycles, in their physical and in their biological components. Studies of this kind form the basis of decisions in the health field which would have to be taken in the case of an accident. (authors) [French] Le developpement rapide de l'energie nucleaire rend urgente la solution des problemes sanitaires poses par le rejet dans le milieu ambiant des

  10. Perceptions locales du changement climatique et mesures d ...

    African Journals Online (AJOL)

    Perceptions locales du changement climatique et mesures d'adaptation dans la ... village, de l'importance représentée par le karité pour les groupes socioculturels. ... l'adaptation de nouvelles cultures en association, la protection des jeunes ...

  11. Les mesures de gel et de confiscation en vertu de la Loi sur les embargos

    OpenAIRE

    Schnyder, Nicolas

    2009-01-01

    Etude du mécanisme d'adoption des mesures de gel et de confiscation en vertu de la Loi sur les embargos et leurs conséquences tant sur la personne principalement touchée par ces mesures que sur les tiers.

  12. Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion

    Energy Technology Data Exchange (ETDEWEB)

    Ohse, R W [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-07-01

    A high temperature apparatus for vapour pressure measurements by Knudsen effusion method is described. Sample is heated in a tungsten cell in an electronic bombardment furnace. Several critical factors affecting the accuracy of measurements such as: - temperature distribution and measurement in the effusion cell, - CLAUSING factor and molecular flow, - compatibility between cell material and sample heated, are discussed with careful attention. Vapour pressure of UO{sub 2} has been studied between 2200 and 2800 K. Experimental points fit a curve expressed by: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) which is in good agreement with previous results of literature. (author) [French] On decrit un appareil destine a la mesure des tensions de vapeur par la methode d'effusion de KNUDSEN. L'echantillon contenu dans une cellule en tungstene est chauffe par bombardement electronique. Apres examen critique des divers facteurs affectant l'exactitude des mesures, a savoir: - homogeneite et mesure de la temperature dans la cellule d'effusion, - facteur de 'CLAUSING' et loi de distribution en cosinus des molecules effusees, - compatibilite a chaud entre le materiau de la cellule et le materiau etudie. On a procede a la mesure de la tension de vapeur de UO{sub 2} qui est relativement bien connue. Entre 2200 et 2800 K les points experimentaux se placent sur une courbe: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) en bon accord avec les valeurs citees dans la litterature. (auteur)

  13. Resistivity measurements using a direct current induction method (1963); Mesure de resistivite par la methode d'induction en courant continu (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Delaplace, J; Hillairet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The conventional methods for measuring electrical resistivities necessitate the fixing of electrical contacts on the sample either mechanically or by soldering. Furthermore it is also necessary to carry,out the measurements on low cross-section samples which are not always easy to obtain. Our direct-current induction method on the other hand requires no contacts and can easily be applied to samples of large cross-section. The sample is placed in a uniform magnetic field; at the moment when the current is cut, eddy currents appear in the sample which tend to oppose the disappearance of the field. The way in which the magnetic flux decreases in the sample makes it possible to determine the resistivity of the material. This method has been applied to samples having diameters of between 1 and 30 mm in the case of metals which are good conductors. It gives a value for the local resistivity and makes it possible to detect any variation along a sample. The measurements can be carried out at all temperature from a few degrees absolute to 500 deg. C. We have used the induction method to follow the purification of beryllium by zone-melting; it is in effect possible to estimate the purity of a material by resistivity measurements. We have measured the resistivity along each bar treated by the zone-melting technique and have thus, localised the purest section. High temperature measurements have been carried out on uranium carbide and on iron-aluminium alloys. This method constitutes an interesting means of investigation the resistivity of solid materials. Its accuracy and rapidity make it particularly adapted both to fundamental research and to production control. (authors) [French] Les methodes classiques de mesure de resistivite electrique imposent la realisation sur l'echantillon de contacts electriques obtenus soit mecaniquement, soit par soudure. En outre, elles demandent, le plus souvent, d'effectuer les mesures sur des echantillons de faible section qu'il n'est pas

  14. The formation of scientists and technicians at the 'Centre d'Etudes Nucleaires' at Saclay; Formation des scientifiques et des techniciens au Centre d'Etudes Nucleaires de Saclay

    Energy Technology Data Exchange (ETDEWEB)

    Debiesse, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The considerable needs in research workers and scientists which are asked by the nuclear energy obliged the Commissariat a l'Energie atomique to deal with a particular effort to increase the quantitative and qualitative formation of scientists. Most various ways have been used. 1- A National Institute of Nuclear Sciences and Nuclear Techniques was created, by a joint decree of the Prime Minister and the Minister for National Education (june 18, 1957). This Institute of Higher Teaching (250 students) indulges in the following matters: atomic engineering, quantum mechanics, theory and technic of particle accelerators, special metallurgy, radiobiology, thermic and mechanics of fluids. 2- An associated centre of the 'Conservatoire National des Arts et Metiers' waeated (200 students) for technical assistants, drawers, etc. 3- In contribution with both electronic industry and Ministry of Work, the Centre d'Etudes Nucleaires contributes to an accelerated formation of technical assistants into Professional Centres. Conclusion: Training of scientists and research workers is one of the most important activities of the Centre d'Etudes Nucleaires de Saclay. Without losing its technical efficiency, it has supplied and varied means adapted to the various purposes that we shall reach. (author)Fren. [French] Les besoins considerables actuels et previsibles en chercheurs et scientifiques necessites par l'avevement de l'energie nucleaire imposaient au Commissariat a I'Energie atomique un effort particulier pour augmenter la formation quantitative et qualitative des scientifiques. Les moyens les plus divers ont ete mis en oeuvre: 1- Creation de l'Institut National des Sciences et Techniques Nucleaires par decret de la Presidence du Conseil et de l'Education Nationale en date du 18.6.57. Cet Institut d'Enseignement Superieur (250 etudiants) donne des cours en: genie atomique, mecanique quantique, theorie et technique des Accelerateurs de particules, metallurgie speciale, radiobiologie

  15. General problems arising from the analogical resolution of the kinetic equations of nuclear reactors (1961); Problemes generaux poses par la resolution analogique des equations cinetiques des reacteurs nucleaires (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Caillet, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The author reviews precisely the analogical techniques used for the resolution of the kinetic equations of nuclear reactors. Prior to this, he recalls the reasons which oblige physicians and engineers, even today, to use electronic machines in this domain. The author then considers the technological problems posed by the range of values which the various nuclear parameters adopt. In each case, he shows that a compromise is possible allowing an optimum precision. He compares the results to those obtained by arithmetic calculation and uses the examples chosen in a critical analysis of the present possibilities of the two methods of calculation. (author) [French] L'auteur cherche a faire un point aussi exact que possible des techniques analogiques utilisees pour resoudre les equations cinetiques des reacteurs nucleaires. Il rappelle auparavant les raisons pour lesquelles physiciens et ingenieurs sont obliges, encore aujourd'hui, de faire appel aux machines electroniques dans ce domaine. Puis il etudie les problemes technologiques que souleve le champ des valeurs prises par les differents parametres nucleaires. Dans chacun des cas, il montre l'existence d'un compromis qui permet d'atteindre une precision optimum. Il compare les resultats obtenus a ceux provenant de calculateurs arithmetiques et profite des exemples choisis pour faire une analyse critique des possibilites actuelles offertes par les deux modes de calcul. (auteur)

  16. Notes on the measurement of stress by resistance gauges in the presence of a magnetic field; Note sur les mesures de contraintes par jauges a fil resistant en presence de champ magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Armand, G; Lapujoulade, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    The technique of stress measurement by resistance gauges is well known. Although it is not yet perfect it possesses many advantages and shows great possibilities. In the presence of a magnetic field the measurement is perturbed by certain phenomena, and we have undertaken to calculate their order of magnitude with a view to establishing the error involved in the measurement. Our problem was to measure the stresses on the various parts of the magnet in the synchrotron Saturne. It is known that the induction passes from a value of about nil to 15000 gauss in 0.8 second, and returns to zero in the same time interval; this cycle recurs every 3.2 seconds. In order to isolate the effects the problem of measurements in a static field will be examined first, after which the results obtained will be extended to the case of dynamic fields. (author) [French] La technique de mesure de contraintes par jauges a fil resistant est bien connue. Elle presente de nombreux avantages, beaucoup de possibilites, bien que n'etant pas encore parfaite. En presence de champ magnetique, la mesure est perturbee par un certain nombre de phenomenes dont nous avons ete conduits a chiffrer l'ordre de grandeur afin de connaitre l'erreur commise lors de la mesure. Precisons qu'il s'agissait pour nous de mesurer les contraintes sur les differents organes de l'aimant du synchrotron Saturne. L'on sait que la valeur de l'induction au droit de l'entrefer passe d'une valeur sensiblement nulle a 15000 gauss en 0,8 secondes, pour revenir ensuite a zero pendant un temps egal au precedent; le cycle ci-dessus se reproduit toutes les 3,2 secondes. Afin de separer les effets, nous examinerons d'abord le probleme des mesures en champ statique puis nous etendrons les resultats obtenus au cas des champs dynamiques. (auteur)

  17. Measurement of a thermal neutron flux using air activation; Mesure de flux de neutrons thermiques par activation d'air

    Energy Technology Data Exchange (ETDEWEB)

    Guyonvarh, M; Lecomte, P; Le Meur, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    It is necessary to know, in irradiation loops, the thermal neutron flux after the irradiation device has been introduced and without being obliged to wait for the discharge of this device. In order to measure the flux and to control it continuously, one possible method is to place in the flux a coiled steel tube through which air passes. By measuring the activity of argon 41, and with a knowledge of the flow rate and the temperature of the air, it is possible to calculate the flux. An air-circulation flux controller is described and the relationship between the flux and the count rate is established The accuracy of an absolute measurement is about 14 per cent; that of a relative measurement is about 3 per cent. The measurement can be carried out equally well whether the reactor is operating at maximum or at low power. The measurement range goes from 10{sup 9} to lO{sup 15} n.cm{sup -2}.sec{sup -1}, and it would be possible after a few modifications to measure fluxes between 10{sup 5} and 10{sup 15} n.cm{sup -2}.sec{sup -1}. Finally, the method is very safe to operate: there is little risk of irradiation because of the low specific activity of the argon-41 formed, and no risk of contamination because the decay product of argon-41 is stable. This method, which is now being used in loops, is thus very practical. (authors) [French] Sur des boucles d'irradiation il est necessaire de connaitre le flux de neutrons thermiques apres mise en place du dispositif d'irradiation et sans etre oblige d'attendre le detournement de ce dispositif. Pour mesurer le flux et le controler en permanence, une methode consiste a placer sous flux un serpentin en acier dans lequel on fait circuler de l'air. La mesure d'activite d'argon 41 permet de calculer le flux, connaissant le debit et la temperature de l'air. Un controleur de flux par circulation d'air est decrit et la relation entre le flux et le taux de comptage est etablie. La precision d'une mesure absolue est de l'ordre de 14 pour

  18. Metrolab a saisi l'opportunite de l'imagerie medicale

    CERN Multimedia

    Peclet, J C

    2003-01-01

    "Le Prix Nobel de medecine a ete decerne lundi a Paul Lauterbur et Peter Mansfield, dont les recherches ont abouti au developpement de l'imagerie par resonance magnetique nucleaire (IRM).... Ces appareils ne fonctionnent correctement que si leur champ magnetique est absolument homogene. Et c'est ici qu'intervient une petite societe genevoise, Metrolab, leader mondial dans la fabrication de magnetometres RMN, qui mesurent tres exactement cette homogeneite" (1/2 page).

  19. Developpement d'une methode calorimetrique de mesure des pertes ac pour des rubans supraconducteurs a haute temperature critique

    Science.gov (United States)

    Dolez, Patricia

    Le travail de recherche effectue dans le cadre de ce projet de doctorat a permis la mise au point d'une methode de mesure des pertes ac destinee a l'etude des supraconducteurs a haute temperature critique. Pour le choix des principes de cette methode, nous nous sommes inspires de travaux anterieurs realises sur les supraconducteurs conventionnels, afin de proposer une alternative a la technique electrique, presentant lors du debut de cette these des problemes lies a la variation du resultat des mesures selon la position des contacts de tension sur la surface de l'echantillon, et de pouvoir mesurer les pertes ac dans des conditions simulant la realite des futures applications industrielles des rubans supraconducteurs: en particulier, cette methode utilise la technique calorimetrique, associee a une calibration simultanee et in situ. La validite de la methode a ete verifiee de maniere theorique et experimentale: d'une part, des mesures ont ete realisees sur des echantillons de Bi-2223 recouverts d'argent ou d'alliage d'argent-or et comparees avec les predictions theoriques donnees par Norris, nous indiquant la nature majoritairement hysteretique des pertes ac dans nos echantillons; d'autre part, une mesure electrique a ete realisee in situ dont les resultats correspondent parfaitement a ceux donnes par notre methode calorimetrique. Par ailleurs, nous avons compare la dependance en courant et en frequence des pertes ac d'un echantillon avant et apres qu'il ait ete endommage. Ces mesures semblent indiquer une relation entre la valeur du coefficient de la loi de puissance modelisant la dependance des pertes avec le courant, et les inhomogeneites longitudinales du courant critique induites par l'endommagement. De plus, la variation en frequence montre qu'au niveau des grosses fractures transverses creees par l'endommagement dans le coeur supraconducteur, le courant se partage localement de maniere a peu pres equivalente entre les quelques grains de matiere

  20. Material movement of medium surrounding an underground nuclear explosion; Mouvement materiel du milieu environnant une explosion nucleaire souterraine

    Energy Technology Data Exchange (ETDEWEB)

    Guerrini, C; Garnier, J L [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The results of measurements of the mechanical effects in the, intermediate zone around underground nuclear explosions in Sahara granite are presented. After a description of the main characteristics of the equipment used, the laws drawn up using experimental results for the acceleration, the velocity, and the material displacement are presented. These laws are compared to those published in other countries for nuclear tests in granite, in tuff and in alluvial deposits. (authors) [French] Les resultats de mesures d'effets mecaniques en zone intermediaire autour d'essais nucleaires souterrains dans le granite du Sahara sont exposes. Apres avoir decrit, dans leurs grandes lignes, les materiels utilises, on presente les lois etablies avec les resultats experimentaux pour l'acceleration, la vitesse et le deplacement materiel. Ces lois sont comparees a celles publiees a l'etranger pour des essais nucleaires dans le granite, le tuf et les alluvions. (auteur)

  1. Description of a Reactivity Measuring Apparatus; Description d'un Type d'Appareil de Mesure de la Reactivite

    Energy Technology Data Exchange (ETDEWEB)

    Deiss, M.; Uberschlag, J. [Centre d' Etudes Nucleaires de Saclay (France)

    1966-06-15

    apparatuses have different dividers in the output unit, in the one case Potentiometric, and in the other electronic. The first apparatus is suitable in principle for most normal measurements. The second, by reason of its shorter response time, is suited both to measurements of higher reactivity values with the reactor level rising, and also with the reactor level falling, even over limited power ranges. (author) [French] La mesure de la periode ou du temps de doublement fournit en general au technicien du controle des reacteurs une information suffisante sur l'evolution du reacteur. Le physicien attache a la determination de parametres physiques ne peut se satisfaire de la mesure ordinaire de ces grandeurs, dont les concepts font abstraction de la nature du phenomene de la fission nucleaire. Habituellement le physicien doit donc convertir la mesure du temps de doublement, effectuee sur un temps suffisamment long, afin d'en eliminer les termes transitoires perturbateurs, et convertir, par intermediaire des courbes de Nordheim, cette mesure en valeur de reactivite. Cette procedure est longue et contraignante. Il a donc semble utile de concevoir un type d'appareil capable d'evaluer directement et instantanement le coefficient de multiplication excedentaire Greek-Small-Letter-Delta K a partir de l'evolution d'une grandeur physique N supposee proportionnelle au flux neutronique regnant dans le coeur du reacteur. Le coefficient Greek-Small-Letter-Delta K est pratiquement assimilable a la reactivite au voisinage de la criticalite. Un appareil de ce type peut en consequence resoudre la relation inverse a celle definie par le systeme des equations differentielles se rapportant au reacteur, en considerant le cas simplifie du reacteur point dans la theorie a un groupe. L'application des techniques du calcul analogique conduit a utiliser un reseau du type Pagels qui sera dispose, soit comme impedance d'entree, soit comme impedance de contre-reaction d'un amplificateur operationnel. Cette

  2. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de fonctionnement et le

  3. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de

  4. Study of a photomultiplier for the measurement of low light flows by photon counting; Etude d'un photomultiplicateur en vue de la mesure des faibles flux lumineux par comptage de photons

    Energy Technology Data Exchange (ETDEWEB)

    Haye, Kleber

    1964-03-20

    After a recall of the history of the discovery and use of the photoemission effect, a presentation of the main characteristics of photomultipliers, a discussion of performance and weaknesses of electron multiplier-based cells, this research thesis addresses the study of low light flows. The author tried to determine whether it was possible, at ambient temperature, to reduce the influence of the thermoelectric effect. In order to do so, he made a detailed study of the amplitude spectrum of pulses of photoelectric origin. In order to analyse the influence of temperature of photomultiplier characteristics, he studied, with respect to temperature, the variation of the counting rate corresponding to darkness, the variation of pulse amplitude spectrum, and relative variations of the quantum efficiency for various wavelengths. In parallel with the study by counting, a study has been performed by using the well known mean current measurement [French] Si l'on veut etudier de faibles flux lumineux, c'est surtout l'effet thermoelectronique qui limite a temperature ambiante le domaine possible des mesures. Les electrons qui arrivent en effet a quitter la photocathode ou les dynodes donnent naissance a des groupes supplementaires d'electrons venant s'ajouter a ceux causes par effet photoelectrique. En utilisant une methode de mesure par comptage des groupes d'electrons, nous nous sommes attaches a determiner s'il etait possible a temperature ordinaire de reduire 1'influence de l'effet thermoelectronique. Pour cela, nous avons fait une etude detaillee du spectre d'amplitude des impulsions d'origine photoelectrique. Toutefois, la solution la plus efficace pour combattre l'effet thermoelectronique etant le refroidissement, nous avons essaye d'analyser l'influence de la temperature sur les caracteristiques du photomultiplicateur. Nous avons ainsi etudie en fonction de la temperature la variation du taux de comptage correspondant a l'obscurite, la variation du spectre d

  5. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy; Realisation d'un appareil pour des mesures d'orientation nucleaire a basse temperature. Application a l'alliage neodyme-cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-10-01

    We describe experiments along which has been studied the anisotropy of {gamma} radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV {gamma} radiation was measured in function of the sample temperature, using as thermometer the anisotropy of {gamma} radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 {+-} 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo{sub 5}). The field at the cobalt in NdCo{sub 5} has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds < Heff(NdCo{sub 5}) < 220000 oersteds. (author) [French] Nous decrivons des experiences au cours desquelles nous avons etudie l'anisotropie de rayonnements {gamma} emis par des noyaux orientes. Nous avons utilise les grands champs hyperfins agissant sur las noyaux dans les metaux ferromagnetiques pour produire l'alignement a basse temperature. Par irradiation nous avons obtenu quelques noyaux de cobalt 60 dans nos echantillons qui furent ensuite refroidis a 0,01 K. Le degre d'anisotropie du rayonnement {gamma} de 1,33 MeV fut mesure en fonction de la temperature de l'echantillon en utilisant l'anisotropie du rayonnement {gamma} de noyaux de cobalt 60 dans un monocristal de cobalt metallique utilise comme thermometre. Le cobalt 60 a ete aligne dans un alliage de cobalt-nickel (40% Ni). Le champ hyperfin au niveau du cobalt a ete mesure par rapport au champ effectif dans le cobalt metallique

  6. Contribution to the study of the action of electromagnetic fields on the angular correlations of nuclear radiation (1960); Contribution a l'etude de l'action des champs electromagnetiques sur les correlations angulaires des rayonnements nucleaires (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-01-15

    This work deals with the study of interaction of E.M. fields with nuclear moments of nuclei emitting gamma rays. We describe first experiments on delayed angular correlation showing the role played by statistic quadrupole interaction. We have measured the magnetic moment of the second excited state of {sup 19}F using an external magnetic field. In the case of {sup 19}O, experiments of angular distributions and angular correlations of gamma -rays taking into account the possibility of perturbations, allow us to determine the spin and parities of the three first levels. (author) [French] Le present travail concerne l'etude de l'interaction des champs electromagnetiques et des moments nucleaires de noyaux emettant des rayonnements gamma. Nous decrivons des experiences de correlation angulaire differee dont l'interpretation met en coincidence le role joue par les interactions quadrupolaires statiques. Nous avons mesure le moment magnetique de {sup 19}F dans un etat excite en utilisant un champ magnetique exterieur a la source radioactive. Enfin, dans le cas de {sup 19}O, nous montrons l'utilite d'un examen des possibilites de perturbations dans l'interpretation des resultats fournis par des correlations ou des distributions angulaires. (auteur)

  7. Neutron measurements in the core and blankets of the reactor Rapsodie; Mesures neutroniques dans le coeur et les couvertures de Rapsodie

    Energy Technology Data Exchange (ETDEWEB)

    Gourdon, J; Edeline, J C [Commissariat a l' Energie Atomique, 13 - Cadarache (France). Centre d' Etudes Nucleaires

    1968-07-01

    Beside a brief general discussion, the report contains all the core and blanket neutronic measurements. It covers successively the methods, the measurements themselves and the results. The later concern: spectral indexes, axial and radial fission rates, activation foil measurements and neutronic power determination. (authors) [French] Apres une breve description generale de RAPSODIE, le rapport presente l'ensemble des mesures neutroniques faites dans le coeur et les couvertures. Il traite dans l'ordre des methodes, des mesures et enfin des resultats qui concernent: les indices de spectres, les taux de fission axiaux et radiaux, les mesures par detecteurs par activation, la determination de la puissance, neutronique. (auteurs)

  8. Contribution to the study of molecular movements in cyclohexane by electron spin resonance and electron-nuclear double resonance using a radical probe; Contribution a l'etude des mouvements moleculaires dans le cyclohexane par resonance paramagnetique electronique et double resonance electronique-nucleaire a l'aide d'une sonde radicalaire

    Energy Technology Data Exchange (ETDEWEB)

    Volino, F [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Solutions of stable free radicals of the nitroxide type have been studied as a function of temperature. In the plastic or globular state, the cyclohexane molecules have rapid rotational and diffusional movements. They transmit this movement to dissolved free radicals. Conversely, measurements by electron spin resonance of the absolute movement of the radicals, and by electron nuclear double resonance of their movement relative to the cyclohexane molecules give very precise methods for local analyses of the movement present in the cyclohexane matrix. The principle of these techniques makes up the 'radical probe method'. (author) [French] Des solutions de radicaux libres stables, du type nitroxyde dans le cyclohexane ont ete etudiees, en fonction de la temperature. Les molecules de cyclohexane, dans l'etat plastique ou globulaire, sont animees de mouvements rapides de rotation sur elles-memes et de diffusion. Elles transmettent leur mobilite aux radicaux libres dissous. Reciproquement, la mesure du mouvement absolu des radicaux, a l'aide de la resonance paramagnetique electronique, et celle du mouvement relatif des radicaux et des molecules de cyclohexane par double resonance electronique-nucleaire, constituent des methodes tres precises pour analyser localement les mouvements presents dans la matrice de cyclohexane. Ce principe et ces techniques constituent la 'methode de la sonde radicalaire'. (auteur)

  9. Contribution to the study of time-resolution in pulse electronics for nuclear physics: phase control circuits; Contribution a l'etude de la resolution en temps de l'electronique impulsionnelle pour physique nucleaire: les circuits de mise en phase

    Energy Technology Data Exchange (ETDEWEB)

    Cortet, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Phase control circuits make it possible to improve quite markedly the time resolution in pulse electronics. They replace a random pulse, of which the time of arrival with respect to a reference zero is being measured, by another pulse whose phase is well determined with respect to that, of a clock taken as reference. The time spectrum of the output, delayed, can always be situated inside channels of width {delta}T defined by the clock. The time statistics of the events analyzed is always correct even if the transition time for the circuits defining the channels represents a large fraction of {delta}T: the coding of the time becomes perfect, The phase control circuits, used in precision chronometry, are widely applied in Nuclear Physics since the lime spectra obtained are representative, indirectly, of certain values which are required to be measured with great accuracy. A description is given of: the constitution and operation of phase control circuits; a chain with automatic analysis and automatic reading, built for testing these circuits. Finally the measurement results are given. (author) [French] Les circuits de mise en phase permettent d'ameliorer notablement la resolution en temps de l'electronique impulsionnelle. Ils substituent a une impulsion aleatoire, dont on cherche a mesurer l'instant d'arrivee par rapport a un instant pris pour origine, une autre impulsion dont la phase est bien determinee par rapport a celle d'une horloge prise comme reference. Le spectre temporel de sortie, retarde, peut toujours etre situe a l'interieur des canaux de largeur {delta}T, definis par l'horloge. La statistique temporelle des evenements analyses est toujours correcte, meme si la duree de transition des circuits definissant les canaux represente une grande fraction de {delta}T: le codage de temps devient parfait. Les circuits de mise en phase, utilises en chronometrie fine, sont tres employes en Physique Nucleaire car les spectres temporels oblenus sont representatifs

  10. Contribution to the study of molecular movements in cyclohexane by electron spin resonance and electron-nuclear double resonance using a radical probe; Contribution a l'etude des mouvements moleculaires dans le cyclohexane par resonance paramagnetique electronique et double resonance electronique-nucleaire a l'aide d'une sonde radicalaire

    Energy Technology Data Exchange (ETDEWEB)

    Volino, F. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Solutions of stable free radicals of the nitroxide type have been studied as a function of temperature. In the plastic or globular state, the cyclohexane molecules have rapid rotational and diffusional movements. They transmit this movement to dissolved free radicals. Conversely, measurements by electron spin resonance of the absolute movement of the radicals, and by electron nuclear double resonance of their movement relative to the cyclohexane molecules give very precise methods for local analyses of the movement present in the cyclohexane matrix. The principle of these techniques makes up the 'radical probe method'. (author) [French] Des solutions de radicaux libres stables, du type nitroxyde dans le cyclohexane ont ete etudiees, en fonction de la temperature. Les molecules de cyclohexane, dans l'etat plastique ou globulaire, sont animees de mouvements rapides de rotation sur elles-memes et de diffusion. Elles transmettent leur mobilite aux radicaux libres dissous. Reciproquement, la mesure du mouvement absolu des radicaux, a l'aide de la resonance paramagnetique electronique, et celle du mouvement relatif des radicaux et des molecules de cyclohexane par double resonance electronique-nucleaire, constituent des methodes tres precises pour analyser localement les mouvements presents dans la matrice de cyclohexane. Ce principe et ces techniques constituent la 'methode de la sonde radicalaire'. (auteur)

  11. Total cross-section measurements on aluminium, carbon, fluorine and hydrogen for d, d reaction neutrons using the coincidence method (1963); Mesure de la section efficace totale de l'aluminium, du carbone, du fluor et de l'hydrogene pour des neutrons de la reaction d, d par la methode des coincidences (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, G; Sorriaux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The experiment described consists in the measurement of the total cross-section of various materials: aluminium, carbon, fluorine and hydrogen, for mono-energetic 2.77 MeV neutrons obtained from the d,d reaction. The measurement is carried out by transmission. The neutrons are detected by means of a plastic scintillator mounted on a 56 AVP photomultiplier, and are isolated from all secondary phenomena (background noise, scattered neutrons) by coincidence with helium 3. which particles are associated to the neutrons from the reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H The helium 3 particles are detected by a PN junction diode used with inverted polarisation. An absorption exponential has been traced out using measurements made on seven aluminium bars. The accuracy of the total cross-section measurements is about 10{sup -2}. (authors) [French] L'experience exposee dans ce rapport consiste en la mesure des sections efficaces totales de differents materiaux: aluminium, carbone, fluor et hydrogene, pour des neutrons monoenergetiques de 2,77 MeV, obtenus par la reaction d,d. La mesure est faite par transmission. Les neutrons sont detectes par un scintillateur plastique monte sur un photomultiplicateur 56 AVP, et sont separes de tout phenomene secondaire (bruit de fond, neutrons diffuses) par coincidence avec les helium 3, particules associees aux neutrons de la reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H Les helium 3 sont detectes par une diode a jonction PN utilisee en polarisation inverse. Une exponentielle d'absorption a ete tracee a partir de mesures faites sur sept barreaux d'aluminium. La precision des mesures des sections efficaces totales est de l'ordre de 10{sup -2}. (auteurs)

  12. Quantitative measurements of small isotopic samples in gaseous mixtures by utilization of some nuclear properties; Etude des possibilites de mesures de faibles quantites de gaz radioactifs dans un melange en utilisant simultanement plusieurs proprietes nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Maragnon, J; Delperie, C

    1967-12-01

    The question is to define the characteristics of a group of measurements allowing the analysis of traces of radioactive rare gases in gas mixtures of different composition. To distinguish the radioactive isotopes from each other and the activity level reaching 10{sup 6} due to their nuclear properties, the method was chosen to use several nuclear properties: gamma radiation energy, beta particle energy, lifetime of excited states. The choice of a plastic scintillator as beta detector allows to answer satisfactorilly to this demand by measurement of nuclear constants because of the short de/excitation time of this detector. Another advantage is that it can be a reservoir for the sample without any destruction nor modification of the sample. The study has been based on the mixture of Kr-85, the analysis of other rare gases follwos immediately from the adopted principle. [French] Les auteurs ont oriente leur recherche vers une solution permettant de distinguer les isotopes radioactifs les uns des autres et dans des rapports d'activite pouvant atteindre 10{sup 6}, grace a plusieurs de leurs proprietes nucleaires, energie de rayonnement gamma, energie de la particule beta, temps de vie des niveaux excites. Le choix d'un scintillateur plastique comme detecteur beta permet de repondre d'une maniere satisfaisante a la mesure des constantes nucleaires en raison du temps de de/excitation rapide de ce scintillateur. Il offre en outre l'avantage de pouvoir servir de reservoir a l'echantillon sans entrainer aucune destruction ni modification de celui-ci. L'etude a ete basee sur la mixture de Kr-85, l'analyse des autre gaz rares decoulant immediatement du principe adopte. (auteur)

  13. The study of neutron transport by oscillation method; Etude du transport des neutrons par la methode de modulation

    Energy Technology Data Exchange (ETDEWEB)

    Raievski, V

    1959-07-01

    The oscillation method is of very general use for studying the behavior of thermal neutrons in media. The main experiments are described and a general theory of them is given. This theory, which is presented in the first part, is established using the two-group approximation which has proved its efficiency in the case of thermal neutron piles. The validity of the two-group approximation is recalled. This allows definition of the meaning of the parameters used in the theory and which are measured in these experiments. The experiments carried out by this method are described, especially those performed at the Centre d'Etudes Nucleaires de Saclay where the method has been extensively used. These experiments are interpreted by means of the general theory given previously. In this way, the identity of parameters measured by this method and those given by the theory is proved. This is particularly conclusive is the case of the mean life of neutrons in a pile. (author) [French] La methode de modulation est un procede tres general d'etude des proprietes neutroniques des milieux contenant des neutrons thermiques. Le present rapport a pour but de decrire les principales de ces experiences et d'en donner une theorie generale. Cette theorie, exposee dans la premiere partie, est etablie dons le cadre de l'approximation a deux groupes de vitesse qui a prouve son efficacite dons le cas des piles a neutrons thermiques. Le domaine de validite de l'approximation a deux groupes est rappele au debut, ce qui permet de definir avec precision la signification des parametres qui entrent dons la theorie et qui font l'objet de ces mesures. La deuxieme partie decrit les experiences realisees, en particulier celles effectuees au Centre d'Etudes Nucleaires de Saclay ou la methode a ete considerablement developpee. Ces experiences sont interpretees dans le cadre de la theorie generale exposee precedemment. On prouve ainsi l'identite des parametres mesures par cette methode et de ceux figurant

  14. Contribution to the measurement of the reflection coefficient for curved crystals between 50 and 80 keV; Contribution a la mesure du coefficient de reflexion de cristaux courbes entre 50 keV et 80 keV

    Energy Technology Data Exchange (ETDEWEB)

    Chartier, J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-09-01

    In the first part, we summarize the main approximate theories dealing with the diffraction of electromagnetic radiation by the crystalline medium, allowing the determination of the characteristic properties of flat and bent crystals used in X and gamma-Ray spectroscopy ('Laue Case'). We describe the experimental setting and we explain our method to measure {gamma}: reflectivity of elastically or plastically bent-crystals from narrow wave-length intervals in the continuous X-Ray spectrum. We discuss our experimental results obtained with different crystals (quartz (3140), Al (200), FLi (200) and compare them with theoretical ones. Finally, we refer to a use of the bent-crystal spectrometer (Cauchois arrangement) in dosimetry. (author) [French] Dans la premiere partie, nous resumons les principales approximations theoriques qui traitent la diffraction du rayonnement electromagnetique par le milieu cristallin et permettent de determiner les grandeurs caracteristiques des lames cristallines planes ou courbees utilisees 'par transmission' en spectroscopie X ou gamma. Apres avoir decrit le montage experimental, nous exposons la methode de mesure de {gamma}: coefficient de reflexion de cristaux courbes (elastiquement ou plastiquement). Le domaine energetique etudie est voisin de 100 keV. Dans cette methode, nous n'utilisons pas des rayonnements monoenergetiques provenant de transitions atomiques ou nucleaires mais des bandes etroites d'energie appartenant au spectre continu du rayonnement emis par un tube a rayons X. Les resultats experimentaux obtenus avec differents cristaux (quartz (3140), Al (200), FLi (200)) sont discutes et compares a ceux prevus par la theorie. Nous mentionnons, enfin, une application en dosimetrie du spectrographe a cristal couche (Geometrie Cauchois). (auteur)

  15. Radioelements: their detection and measurement; Les radioelements: detection et mesure

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A brief review of the properties of nuclear radiations is followed by a description of the basic techniques used for their detection: autoradiography, methods using the ionisation of gases (ionisation chambers, proportional counters, Geiger-Muller counters), scintillation techniques. The principles of the different methods of measurement are explained, whether they concern the activity or the energy absorbed (dosimetry). This is followed by a description of the basic techniques (4 {pi} counter, defined solid angle, {beta}-{gamma} coincidences). (author) [French] Apres un bref rappel des proprietes des rayonnements nucleaires, on decrit les techniques fondamentales employees pour leur detection: autoradiographie, procedes utilisant l'ionisation des gaz (chambres d'ionisation, compteurs proportionnels, compteurs de Geiger-Muller), technique des scintillations. On expose le principe des differentes methodes de mesure concernant soit l'activite, soit l'energie absorbee (dosimetrie). Les techniques fondamentales (compteur 4 {pi}, angle solide defini, coincidences {beta}-{gamma}) sont ensuite decrites. (auteur)

  16. Contribution to the study of the action of electromagnetic fields on the angular correlations of nuclear radiation (1960); Contribution a l'etude de l'action des champs electromagnetiques sur les correlations angulaires des rayonnements nucleaires (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-01-15

    This work deals with the study of interaction of E.M. fields with nuclear moments of nuclei emitting gamma rays. We describe first experiments on delayed angular correlation showing the role played by statistic quadrupole interaction. We have measured the magnetic moment of the second excited state of {sup 19}F using an external magnetic field. In the case of {sup 19}O, experiments of angular distributions and angular correlations of gamma -rays taking into account the possibility of perturbations, allow us to determine the spin and parities of the three first levels. (author) [French] Le present travail concerne l'etude de l'interaction des champs electromagnetiques et des moments nucleaires de noyaux emettant des rayonnements gamma. Nous decrivons des experiences de correlation angulaire differee dont l'interpretation met en coincidence le role joue par les interactions quadrupolaires statiques. Nous avons mesure le moment magnetique de {sup 19}F dans un etat excite en utilisant un champ magnetique exterieur a la source radioactive. Enfin, dans le cas de {sup 19}O, nous montrons l'utilite d'un examen des possibilites de perturbations dans l'interpretation des resultats fournis par des correlations ou des distributions angulaires. (auteur)

  17. Some magnetic resonance properties of solutions of sodium in liquid ammonia; Contribution a l'etude des solutions de sodium dans l'ammoniac liquide par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-02-01

    Dilute solutions of sodium in liquid ammonia are studied by the mean of dynamic polarization techniques, and with the aid of Becker Lindquist and Alder model. Paramagnetic shifts are computed as a function of the 'average spin density', for each of the nuclear spin system. The nuclear contributions to the Overhauser shift are computed in the same way. A theoretical study of the main relaxation processes is carried out for each of the nuclear spin system and for the electronic spin system. The dynamic polarization experiments consist in classical measurement of the Overhauser enhancement for nitrogen, and in direct measurements of nitrogen Knight shift and nuclear contributions to the Overhauser shift by the mean of double irradiation techniques. The results show that, in dilute solutions, the relaxation of nitrogen arises from quadrupole interaction and from hyperfine interaction with unpaired electrons. Both interactions are of the same order of magnitude. Overhauser shift measurements show that the spin density is negative at the proton site, in agreement with Hughes results. (author) [French] Les solutions diluees de sodium dans l'ammoniac sont etudiees au moyen des techniques de la polarisation dynamique, sur la base du modele de Becker Lindquist et Aider. Les deplacements paramagnetiques des raies de resonance nucleaire des differents noyaux sont analyses en faisant appel a la notion de ''densite moyenne de spin'' introduite par l'auteur; et les differentes contributions nucleaires au deplacement d'Overhauser sont calculees en fonction de cette meme grandeur. Une etude theorique de la relaxation de chaque systeme de spin permet d'evaluer l'importance relative des differents mecanismes mis en jeu. Les experiences de polarisation dynamique effectuees au cours de ce travail consistent en mesures classiques de l'effet Overhauser sur l'azote, d'une part, et en la mise en oeuvre de techniques originales pour mesurer le deplacement de Knight de l'azote et les

  18. Radioelements: their detection and measurement; Les radioelements: detection et mesure

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A brief review of the properties of nuclear radiations is followed by a description of the basic techniques used for their detection: autoradiography, methods using the ionisation of gases (ionisation chambers, proportional counters, Geiger-Muller counters), scintillation techniques. The principles of the different methods of measurement are explained, whether they concern the activity or the energy absorbed (dosimetry). This is followed by a description of the basic techniques (4 {pi} counter, defined solid angle, {beta}-{gamma} coincidences). (author) [French] Apres un bref rappel des proprietes des rayonnements nucleaires, on decrit les techniques fondamentales employees pour leur detection: autoradiographie, procedes utilisant l'ionisation des gaz (chambres d'ionisation, compteurs proportionnels, compteurs de Geiger-Muller), technique des scintillations. On expose le principe des differentes methodes de mesure concernant soit l'activite, soit l'energie absorbee (dosimetrie). Les techniques fondamentales (compteur 4 {pi}, angle solide defini, coincidences {beta}-{gamma}) sont ensuite decrites. (auteur)

  19. Développement de la pupillométrie pour la mesure objective des émotions dans le contexte de la consommation alimentaire

    OpenAIRE

    Lemercier, Anaïs

    2014-01-01

    Les perceptions sensorielles et hédoniques résultent de processus complexes d’intégration, qui ne sont pas seulement rationnels, mais aussi fondés sur des sentiments, des émotions et des souvenirs. Afin d'appréhender au mieux le comportement du consommateur, il est devenu indispensable de mesurer les émotions afin de comprendre leur rôle fondamental dans la prise de décision. En science du consommateur, les émotions sont principalement mesurées par questionnaire. Malheureusement, cette mesure...

  20. Health physics problems in the context of the development of industrial uses of nuclear energy; Les problemes de radioprotection devant le developpement de l'utilisation industrielle de l'energie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Duhamel, F; Menoux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    fate of radioactive ions in the hydrosphere may be determined. - experiments and studies linked with the possibilities for disposal a underground storage of wastes. All these studies cover a complementary field, that of radioprotection, which forms the necessary link between nuclear safety proper, which concerns the actual operation of nuclear installations and medical supervision which directly concerns the health of the individual and the population. At the same time each one of the Health Physics disciplines possesses an independence which increases their efficiency on the safety level. (authors) [French] Le developpement de l'utilisation industrielle de l'energie nucleaire a mis l'accent sur la necessite de promouvoir une doctrine rationnelle et coherente en matiere de securite des installations atomiques et plus particulierement en matiere de securite des sites nucleaires. Le but principal de la securite est de diminuer, voire d'annuler les risques d'irradiation ou de contamination des travailleurs et de la population, consecutifs au fonctionnement normal ou accidentel des installations. La securite est obtenue par la mise en oeuvre d'un ensemble complexe de moyens. Parmi ces moyens les auteurs considerent essentiellement ceux qui presentent une certaine independance a l'egard du type d'installation: moyens d'alerte et de mesure et leur mise en oeuvre - preparation psychologique et technique des individus - evaluation de la capacite d'un site a absorber les rejets radioactifs sans dommage pour la population. Il est clair en effet que les consequences d'un accident sont diminuees par l'augmentation de la valeur des moyens de surveillance, de mesure et d'alerte, l'elevation du niveau technique et l'entrainement du personnel, l'education de la population. Ceci est particulierement vrai aupres d'une installation nucleaire ou l'etude des dangers presente un caractere abstrait et ou les moyens technologiques de protection sont multiples et complexes. Les etudes de

  1. Study of once and twice forbidden {beta} transitions; Contribution a l'etude de transitions {beta} une fois et deux fois interdites

    Energy Technology Data Exchange (ETDEWEB)

    Hocquenghem, J C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-09-01

    The realisation of an experimental set up for directional angular correlation measurements allowed us to determine {beta} - {gamma} angular correlations. These measurements together with the determination of the {beta} shape-factor have been made for the following transitions: the first forbidden {beta}{sup -} transitions of 386 keV in the {sup 177}Lu disintegration and of 352 keV in the {sup 175}Yb disintegration. The experimental results have been compared with theoretical predictions of the Nilsson's model; the twice forbidden {beta}{sup -} transition of 473 keV in the {sup 94}Nb disintegration. The {beta} transition nuclear matrix elements have been extracted from the experimental results. Comparison have been made with the theoretical values calculated by taking for nuclear wavefunctions those obtained by diagonalization of the residual interaction and assuming that protons and neutrons outside the {sup 90}Zr core are respectively on the 1 g 9/2 and 2 d 5/2 orbits. (author) [French] La realisation d'un ensemble de mesures de correlations angulaires directionnelles nous a permis la mesure de correlations {beta} - {gamma} en fonction de l'energie. En completant celles-ci par la mesure du facteur de forme du spectre {beta}, nous avons pu etudier ainsi: d'une part, les transitions {beta}{sup -} une fois interdites de 386 keV de la desintegration de {sup 177}Lu et de 352 keV de la desintegration de {sup 175}Yb, Les resultats experimentaux ont ete compares aux valeurs calculees dans le modele de Nilsson; d'autre part, la transition {beta}- deux fois interdite de 473 keV de la desintegration de {sup 94}Nb. Les elements de matrice nucleaire de la transition {beta}, extraits des resultats experimentaux, ont ete compares aux valeurs theoriques calculees. Les fonctions d'ondes nucleaires utilisees ont ete obtenues par diagonalisation de l'interaction residuelle en supposant que les protons et les neutrons, en dehors du coeur forme par le {sup 90}Zr, sont respectivement

  2. Mesure de la fraction d'evenements a quatre quarks dans les desintegrations multihadroniques du boson Z au LEP

    Science.gov (United States)

    Lefebvre, Eric

    Cette thèse propose de tester la Chromodynamique Quantique (QCD) en effectuant une mesure précise d'une des trois constantes fondamentales du groupe de symétrie SU(3) utilisé pour décrire la physique des interactions fortes. Cette constante fondamentale, appelée TF, est reliée à certains états finaux spécifiques des désintégrations du Z0. Ces états apparaissent sous forme de perturbations du deuxième ordre en as et sont illustrés par des diagrammes de Feynman. À cet ordre, la chromodynamique prévoit deux types de diagrammes de Feynman distincts; le premier contient, un quark, un antiquark et deux gluons, et le second, deux quarks et deux antiquarks. La constante TF est directement proportionnelle à la fraction d'événements à deux quarks et deux antiquarks qui est l'objet de notre mesure. Notre mesure est fondée sur l'étude des événements à quatre partons dans l'état final. Ces quatre partons, en s'hadronisant, produisent quatre jets de particules qui peuvent être détectés expérimentalement et identifiés à l'aide d'algorithmes de reconstruction des jets. Des observables angulaires nous permettent de faire une discrimination parmi les états finaux de la désintégration du Z0, et ainsi déterminer la valeur de la fraction d'événements à deux quarks et deux antiquarks fq. Cette fraction peut s'exprimer par le rapport de la fraction observée expérimentalement fexq sur la fraction théorique fthq , R4q=fex qfthq. Afin d'améliorer la mesure de cette fraction et de diminuer le bruit causé par une contamination des événements d'ordres supérieurs, nous avons développe une méthode d'extrapolation. Cette méthode s'appuie sur la caractérisation de l'espace de phase des événements, exprimée par les paramètres yij. Les mesures de R4q que nous obtenons sont: R4q=2,27+0,29 -0,56 à l'aide d'une méthode conventionnelle avec la condition de sélection y34 > 0,020 > y45, et R4q=1,22+0,56 -0,71 à l'aide de notre méthode d

  3. The controlled of the materials by the method of oscillation at the reactor core of Chatillon; Le controle des materiaux par la methode d'oscillation a la pile de Chatillon

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Nuclear controls has for aim to determine the validity of materials intended to be used for the construction of the reactor core. The cross-section of capture of these materials has to be measured while comparing them either to a standard of the same material, either to an element of cross-section supposed known. We studied the disruption of the working of the reactor generated by the periodic introduction of a sample of the studied material. This method is based on the measure of the phase angle of the signal provided by the ionization chamber. This signal results from the composition of a local signal and an aggregate signal due to the effects of diffusion and capture. This method permits the comparison of the capture of 2 samples very dispersive and few capturing as the graphite, the beryllium, the beryllium oxide, with a good precision. It permits to determine the cross-section of capture of elements as magnesium or aluminum. (M.B.) [French] Le controle nucleaire a pour but de determiner la valeur des materiaux destines a etre utilises pour la construction des piles. II s'agit de mesurer la section efficace de capture de ces materiaux en les comparant soit a un echantillon etalon du meme materiau, soit a un element de section efficace supposee connue. On etudie la perturbation du fonctionnement de la pile engendree par l'introduction periodique d'un echantillon du materiau a etudier. Cette methode est basee sur la mesure de l'angle de phase du signal fourni par la chambre d'ionisation. Ce signal resulte de la composition d'un signal local et d'un signal global dus aux effets de diffusion et de capture. Cette methode permet la comparaison de la capture de 2 echantillons de corps tres diffusants et peu capturants comme le graphite,le beryllium, l'oxyde de beryllium, avec une bonne precision. Elle permet par ailleurs de determiner la section efficace de capture de corps tels que le magnesium ou l'aluminium. (M.B.)

  4. Special Nuclear Material Control by the Power Reactor Operator; Controle des Matieres Nucleaires Speciales par l'Exploitant d'une Centrale Nucleaire; Spetsial'nyj kontrol' nalichiya yadernykh materialov operatorom ehnergeticheskogo reaktora; Control de Materiales Nucleares Especiales por Parte de Quienes Operan el Reactor de Potencia

    Energy Technology Data Exchange (ETDEWEB)

    Cordin, R. A. [Yankee Atomic Electric Company, Boston, MA (United States)

    1966-02-15

    insurance programme. (author) [French] L'uranium, combustible relativement nouveau et extremement interessant pour la production d'electricite, doit faire l'objet d'un controle tres strict depuis le moment ou l'exploitant de la centrale en devient financierement responsable jusqu'a celui oti, sous forme de combustible partiellement epuise, la matiere est transferee dans une autre installation et oti l'on recupere ce qui reste de sa valeur initiale. La plupart des exploitants de centrales nucleaires dirigeaient des centrales alimentees par des combustibles fossiles avant l'avenement de l'energie nucleaire et ils ont etabli depuis longtemps un controle etendu et efficace de ces combustibles fossiles. L'exploitant d'une centrale nucleaire doit exercer un controle non moins efficace sur les matieres nucleaires speciales utilisees dans son installation. La technique de l'exploitation des centrales nucleaires n'est pas ancienne et, au cours de, son existence relativement breve, les ingenieurs et hommes de science des Etats-Unis ont constamment ameliore les plans des centrales et les methodes d'exploitation afin de reduire les couts et de permettre aux centrales nucleaires de concurrencer les centrales classiques. La gestion des matieres nucleaires doit etre aussi moderne et efficace que possible pour assurer que les progres technologiques grace auxquels les prix on pu etre reduits ne soient pas mis en echec par des insuffisances dans la manipulation du combustible nucleaire et la tenue de la comptabilite des stocks. Pour assurer la gestion des matieres nucleaires, il faut que l'exploitant de la centrale etablisse et tienne a jour une comptabilite complete et detaillee, sans etre necessairement complexe pour autant; en fait, la simplicite est extremement souhaitable. Bien que le combustible nucleaire soit nouveau et qu'il n'ait rien de commun avec les combustibles classiques, aucun secret ne doit s'y attacher. Le controle des matieres nucleaires dans le cadre de la gestion des

  5. Measuring device for strong gamma-ray sources; Dispositif de mesure des fortes sources emettrices {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelman, J; Vagner, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    We are given the description of a hollow argon-filled cylindrical ionisation chamber which is to be used to measure gamma-emitting sources. The instrument is currently used at the Measures Department in routine gauging of some radioelements. Sources are introduced into the central part of the chamber through a remote handling device. Measures are directly registered, it is not worth while removing the source from the container; a deviation of the source has little effect on the ionization current. The chamber was gauged to test such elements as: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. Its measuring power approximately ranges from 100 micro-curies to 5 curies. (author) [French] On decrit une chambre d'ionisation cylindrique creuse, a remplissage d'argon, destinee a la mesure des sources emettrices {gamma}. Cet appareil est utilise couramment par la Section Mesures pour l'etalonnage de routine d'un certain nombre de radioelements. Les sources sont mises en place au centre de la chambre par un dispositif de manipulation a distance. La mesure est faite directement, sans qu'il soit necessaire d'extraire la source de son container; un decentrement de la source n'a en effet pas d'influence sensible sur le courant d'ionisation. Cette chambre d'ionisation a ete etalonnee pour divers radioelements: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. La flamme d'activite mesurable s'etend de 100 microcuries a 5 curies, environ. (auteur)

  6. Chemical elimination of alumina in suspension in nuclear reactors heavy water; Elimination de l'alumine en suspension dans l'eau lourde des reacteurs nucleaires par voie chimique

    Energy Technology Data Exchange (ETDEWEB)

    Ledoux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-02-01

    Corrosion of aluminium in contact with moderating water in nuclear reactor leads to the formation of an alumina hydrosol which can have an adverse effect on the operation of the reactor. Several physical methods have been used in an attempt to counteract this effect. The method proposed here consists in the elimination of the aluminium by dissolution and subsequent fixation in the ionic form on mixed-bed ion-exchange resin. In order to do this, the parameters and the values of these parameters most favorable to the dissolution process have been determined. If the moderator is heavy water, the deuterated acid can be prepared by converting a solution in heavy water to a salt of the acid using a deuterated cationic resin. (author) [French] La corrosion de l'aluminium au contact de l'eau moderatrice des reacteurs nucleaires, donne lieu a la formation d'un hydrosol d'alumine nuisible au bon fonctionnement des reacteurs. Plusieurs methodes physiques ont ete mises en oeuvre pour pallier ces inconvenients. On propose ici d'eliminer l'alumine par solubilisation pour la fixer ensuite sous forme ionique par des resines echangeuses d'ions, en lit melange. A cette fin on determine les parametres et leurs grandeurs favorables a cette solubilisation. Si le moderateur est de l'eau lourde la preparation d'acide deutere peut etre effectuee par passage d'une solution en eau lourde a un sel de l'acide sur resine cationique deuteree.

  7. Health physics problems in the context of the development of industrial uses of nuclear energy; Les problemes de radioprotection devant le developpement de l'utilisation industrielle de l'energie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Duhamel, F.; Menoux, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    fate of radioactive ions in the hydrosphere may be determined. - experiments and studies linked with the possibilities for disposal a underground storage of wastes. All these studies cover a complementary field, that of radioprotection, which forms the necessary link between nuclear safety proper, which concerns the actual operation of nuclear installations and medical supervision which directly concerns the health of the individual and the population. At the same time each one of the Health Physics disciplines possesses an independence which increases their efficiency on the safety level. (authors) [French] Le developpement de l'utilisation industrielle de l'energie nucleaire a mis l'accent sur la necessite de promouvoir une doctrine rationnelle et coherente en matiere de securite des installations atomiques et plus particulierement en matiere de securite des sites nucleaires. Le but principal de la securite est de diminuer, voire d'annuler les risques d'irradiation ou de contamination des travailleurs et de la population, consecutifs au fonctionnement normal ou accidentel des installations. La securite est obtenue par la mise en oeuvre d'un ensemble complexe de moyens. Parmi ces moyens les auteurs considerent essentiellement ceux qui presentent une certaine independance a l'egard du type d'installation: moyens d'alerte et de mesure et leur mise en oeuvre - preparation psychologique et technique des individus - evaluation de la capacite d'un site a absorber les rejets radioactifs sans dommage pour la population. Il est clair en effet que les consequences d'un accident sont diminuees par l'augmentation de la valeur des moyens de surveillance, de mesure et d'alerte, l'elevation du niveau technique et l'entrainement du personnel, l'education de la population. Ceci est particulierement vrai aupres d'une installation nucleaire ou l'etude des dangers presente un caractere abstrait et

  8. Dynamic method for the measurement of Young'S modulus. Application to nuclear graphites; Methode de mesure dynamique du module d'Young. Application aux graphites nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Pattou, F; Trutt, J C

    1963-07-01

    A dynamic method has been developed for measuring Young's modulus and the rigidity modulus using the 'Forster Elastomat'. The principle consists in the determination of the resonance frequencies of graphite samples submitted to transverse, longitudinal, and torsional vibrations. The first two modes of vibration make it possible to calculate the elasticity modulus or the Young's modulus E, the third mode makes possible the calculation of the rigidity modulus G. The relationships from which the moduli E and G are measured are given. A systematic study has been made of graphite samples produced by extrusion or compression and submitted afterwards to one or several impregnations with pitch. For graphites made from the same coke by the same method, a linear relationship has been found for Young's modulus as a function of the apparent density. For the same apparent density, graphites made from different starting materials have generally different Young's moduli that bear a relationship to the crystalline characteristics of the material. The measurements of the rigidity modulus C made on different graphites also show the influence of crystallite orientation. (authors) [French] Une methode de mesure dynamique du module d'Young et du module de rigidite du graphite utilisant 'l'Elastomat Forster' a ete mise au point. Le principe consiste a determiner les frequences de resonance d'echantillons de graphite soumis a des vibrations transversales, longitudinales et de torsion. Les deux premiers modes de vibration permettent de calculer le module d'elasticite ou module d'Young E, le troisieme mode de vibration permet de calculer le module de rigidite G. Apres avoir decrit la methode de mesure, on rappelle les relations qui permettent de calculer les modules E et G. L'etude systematique d'echantillons de graphite, fabriques par filage ou pressage et ayant subi eventuellement une ou plusieurs impregnations au brai a ete effectuee. Pour les graphites issus du meme coke et fabriques

  9. Measurement of a neutral particle flux by a thermal method using the junction temperature effect; Mesure d'un flux de particules neutres par une methode thermique mettant a contribution l'effet de temperature des jonctions

    Energy Technology Data Exchange (ETDEWEB)

    Caron, Anthime [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Services Scientifiques

    1966-07-01

    Among all the methods suitable for measuring neutral particle fluxes obtained by proton charge exchange in an organic gas, the thermal method has been chosen. The energy imparted by the neutral particles to the target in the form of heat leads to the latter temperature increasing; this temperature is usually followed with a thermocouple. In order to increase the sensitivity and the elegance of the apparatus the thermocouple has been replaced by a junction whose characteristics are known to vary with temperature. A calibration is carried out using a beam of charged particles. The response obtained is linear. Measurements have been made with a power of up to 1 mW; the accuracy increases with the energy provided; for 4 joules an accuracy of 10 per cent is obtained. The apparatus may be improved in particular by extending the measurement range towards low power values, and by increasing the accuracy. (author) [French] Parmi toutes les methodes utilisees pour la mesure d'un flux de particules neutres, obtenues par echange de charge de protons dans un gaz organique, nous avons choisi la methode thermique. L'energie cedee par les particules neutres a la cible sous forme de chaleur provoque une elevation de temperature de celle-ci; cette temperature est habituellement reperee par thermocouple. Pour accroitre la sensibilite et la finesse de l'appareillage, nous avons substitue au thermocouple une jonction dont on sait que les caracteristiques varient avec la temperature. Un etalonnage est realise par un faisceau de particules chargees. La reponse obtenue est lineaire. Des puissances de l'ordre du mW ont ete mesurees; la precision croit avec l'energie apportee; elle est de 10 pour cent quand celle-ci est de 4 joules. L'appareillage peut etre notablement perfectionne, pour reculer la gamme des mesures vers les basses puissances et accroitre la precision. (auteur)

  10. New features of nuclear excitation by {alpha} particles scattering; Nouveaux aspects de l'excitation nucleaire par diffusion de particules {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Saudinos, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Inelastic scattering of medium energy a particles by nuclei is known to excite preferentially levels of collective character. We have studied the scattering of isotopically enriched targets of Ca, Fe, Ni, Cu, Zn. In part I, we discuss the theoretical features of the interaction. In part II, we describe the experimental procedure. Results are presented and analysed in part III. {alpha} particles scattering by Ca{sup 40} is showed to excite preferentially odd parity levels. In odd nuclei we have observed multiplets due to the coupling of the odd nucleon with the even-even core vibrations. For even-even nuclei, a few levels are excited with lower cross-sections between the well-known first 2{sup +} and 3{sup -} states. Some could be members of the two phonon quadrupole excitation and involve a double nuclear excitation process. (author) [French] On sait que la diffusion inelastique des particules alpha de moyenne energie excite preferentiellement des niveaux de caractere collectif. Nous avons etudie la diffusion des particules alpha de 44 MeV du cyclotron de Saclay par des isotopes separes de Ca, Fe, Ni, Cu, Zn. Dans la premiere partie nous exposons les theories de cette interaction. Dans la seconde nous decrivons le systeme experimental. Les resultats sont donnes dans la troisieme partie. Nous montrons que les niveaux excites preferentiellement pour {sup 40}Ca par diffusion ({alpha},{alpha}') sont de parite negative. Dans les noyaux pair-impair nous avons observe des multiplets dus au couplage du nucleon celibataire avec les vibrations du coeur pair-pair. Pour les noyaux pair-pair nous avons pu etudier entre le premier niveau 2{sup +} et le niveau 3{sup -} deja bien connus certains etats plus faiblement excites. Il semble qu'ils sont dus a une excitation quadrupolaire a deux phonons et impliquent un processus de double excitation nucleaire. (auteur)

  11. Contribution to the study of solid helium-3 by nuclear magnetic resonance; Contribution a l'etude de l'helium trois solide par resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Landesman, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    Due to the unusually large zero point motion of helium three atoms in the solid, the overlap of the atomic wave functions is very important. As a consequence, there are exchange interactions, the theoretical calculation and the experimental measurement of which are discussed. Nuclear magnetic resonance is especially well suited for the latter.A detailed theory is given for both exchange narrowing and Zeeman-exchange cross relaxation, which phenomena are used to measure the exchange interaction as a function of molar volume. The alignment temperature is thus known; it goes down when the pressure goes up and is never higher than three milli degrees. An influence of helium four impurities on the exchange interactions between helium three atoms which are neighbours of the substitutional He is shown. (author) [French] Par suite de l'amplitude exceptionnelle des mouvements de point zero dans l'helium trois solide, le recouvrement des fonctions d'onde atomiques est tres important. Il en resulte des interactions d' echange dont on discute l'evaluation theorique et la mise en evidence experimentale. Cette derniere peut se faire par resonance magnetique; on etudie theoriquement les phenomenes de retrecissement par echange et de relaxation Zeeman-echange que l'on met a profit pour determiner les interactions d'echange en fonction du volume molaire. On en deduit que la temperature d'alignement nucleaire diminue quand on comprime le solide et est au plus de 3x10{sup -3} K. L'influence des impuretes d'helium quatre sur les interactions d'echange entre atomes {sup 3}He voisins de {sup 4}He est mise en evidence. (auteur)

  12. Contribution to the study of nuclear resonance in magnetic media (1963); Contribution a l'etude de la resonance nucleaire dans les milieux magnetique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann-Boutron, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    An attempt is made to interpret the results of nuclear magnetic resonance experiments made by various workers on ferro and ferrimagnetic compounds of the iron group. The problems encountered are the following: effects of the dipolar fields and the hyperfine structure anisotropy; signal intensity; frequency pulling due to the Suhl-Nakamura interaction between nuclear spins ; nuclear relaxation and ferrimagnetic resonance in single domain samples of impure YIG; nuclear relaxation in the Bloch walls of insulators. The results of our calculations are generally in good agreement with experiment. (author) [French] On se propose d'interpreter les resultats d'experiences de resonance magnetique nucleaire fates par divers auteurs sur des composes ferro et ferrimagnetiques du groupe du fer. Les problemes abordes sont les suivants: effets des champs dipolaires et de l'anisotropie de structure hyperfine; intensite des signaux; deplacement de frequence du a l'interaction de Suhl-Nakamura entre spins nucleaires; relaxation nucleaire et resonance ferrimagnetique dans les echantillons monodomaines de grenat de fer et d'yttrium impur; relaxation nucleaire dans les parois de Bloch des isolants. Les resultats des calculs sont generalement en bon accord avec l'experience. (auteur)

  13. Automatic magnetic susceptibility measurements between 4 K and 1200 K; Mesure automatique des susceptibilites magnetiques de 4 K a 1200 K

    Energy Technology Data Exchange (ETDEWEB)

    Raphael, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    We give a detailed description of a Faraday magnetic susceptibility balance which operates from 4 K to 1200 K. Some preliminary results on platinum and tantalum illustrate the precision and the sensitivity of the measurements. The apparatus has been designed for measurements on the plutonium compounds which present severe health hazards. (author) [French] Nous decrivons en detail un appareil permettant la mesure des susceptibilites magnetiques de 4 K a 1200 K par la methode de FARADAY. Quelques resultats preliminaires sur le platine et le titane montrent la precision et la sensibilite des mesures, L'appareil a ete adapte aux mesures sur les composes particulierement dangereux du plutonium. (auteur)

  14. Dispositif de mesure de pertes dans les conducteurs supraconducteurs utilisés en régime variable

    Science.gov (United States)

    Le Naour, S.; Lacaze, A.; Laumond, Y.

    1998-01-01

    A thermometric apparatus to measure AC losses in superconductor wires for 50 Hz applications is described. This method consists in isolating the sample from a helium bath via a thermal resistance. Dissipated power is determined by two thermometers located on both edges of a thermal resistance. The measurement's calibration is done using an ohmic heater. The measurement accuracy is 10% for losses in excess of 2 mW/m. Un dispositif expérimental, pour mesurer les pertes générées dans les conducteurs supraconducteurs utilisés en régime alternatif 50 Hz, est décrit. La méthode, basée sur le principe thermométrique, consiste à isoler l'échantillon du bain d'hélium par une résistance thermique. La puissance dissipée est déterminée à l'aide de deux sondes de température disposées de part et d'autre de la résistance. L'étalonnage de la mesure est assuré par une chaufferette. La précision des mesures est de 10% pour des pertes linéiques supérieures à 2 mW/m.

  15. Fast measure proceeding of weak currents; Un procede de mesure rapide des courants faibles

    Energy Technology Data Exchange (ETDEWEB)

    Taieb, J [Commissariat a l' Energie Atomique, Siege (France). Centre d' Etudes Nucleaires

    1953-07-01

    The process of fast measure of the weak currents that we are going to describe briefly apply worthy of the provided currents by the sources to elevated value internal resistance, as it is the case for the ionization chamber, the photocells, mass spectroscopic tubes. The problem to measure weak currents is essentially a problem of amplifier and of input circuit. We intended to achieve a whole amplifier and input circuit with advanced performances, meaning that for a measured celerity we wanted to have an signal/noise ratio the most important as in the classic systems and for a same report signal/noise a more quickly done measure. (M.B.) [French] Le procede de mesure rapide des courants faibles que nous allons brievement decrire s'applique a la mesure des courants fournis par les sources a resistance interne de valeur elevee, comme c'est le cas pour les chambres d'ionisation, les photocellules, les tubes de spectrographe de masse. Le probleme de mesure de courants faibles est essentiellement un probleme d'amplificateur et de circuit d'entree. Nous nous sommes proposes de realiser un ensemble amplificateur et circuit d'entree a performances poussees, c'est a dire que pour une meme rapidite de mesure nous desirions avoir un rapport signal/bruit plus important que dans les systemes classiques et pour un meme rapport signal/bruit une mesure effectuee plus rapidement. (M.B.)

  16. Contribution to the study of nuclear resonance in magnetic media (1963); Contribution a l'etude de la resonance nucleaire dans les milieux magnetique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann-Boutron, F. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    An attempt is made to interpret the results of nuclear magnetic resonance experiments made by various workers on ferro and ferrimagnetic compounds of the iron group. The problems encountered are the following: effects of the dipolar fields and the hyperfine structure anisotropy; signal intensity; frequency pulling due to the Suhl-Nakamura interaction between nuclear spins ; nuclear relaxation and ferrimagnetic resonance in single domain samples of impure YIG; nuclear relaxation in the Bloch walls of insulators. The results of our calculations are generally in good agreement with experiment. (author) [French] On se propose d'interpreter les resultats d'experiences de resonance magnetique nucleaire fates par divers auteurs sur des composes ferro et ferrimagnetiques du groupe du fer. Les problemes abordes sont les suivants: effets des champs dipolaires et de l'anisotropie de structure hyperfine; intensite des signaux; deplacement de frequence du a l'interaction de Suhl-Nakamura entre spins nucleaires; relaxation nucleaire et resonance ferrimagnetique dans les echantillons monodomaines de grenat de fer et d'yttrium impur; relaxation nucleaire dans les parois de Bloch des isolants. Les resultats des calculs sont generalement en bon accord avec l'experience. (auteur)

  17. Thermal, intermediate and fast neutron flux measurements using activation detectors; Mesure des flux de neutrons thermiques, intermediaires et rapides au moyen de detecteurs par activation

    Energy Technology Data Exchange (ETDEWEB)

    Brisbois, J; Lott, M; Manent, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of neutron flux measurements using activation detectors is studied in the particular case of protection research. It is shown how it possible, it is possible, using a known thermal flux, to organise a coherent calibration system for all the detectors. The rapid neutron detectors are calibrated with respect to a reference detector (phosphorus) in a natural uranium converter; the intermediate neutron detectors with respect to gold in the axial channel of ZOE. This method makes it possible to minimise the errors due to the activation cross-sections. A brief description is given of the counting room of the Pile Safety Study Service, as well of the practical utilisation characteristics of the counters employed. (authors) [French] Le probleme de la mesure des flux de neutrons au moyen de detecteurs par activation est etudie dans le cas particulier des etudes de protections. On montre comment, a partir d'un flux thermique connu, on peut organiser un systeme coherent d'etalonnage de tous les detecteurs. Les detecteurs de neutrons rapides sont etalonnes par rapport a un detecteur de reference (phosphore) dans un convertisseur en uranium naturel; les detecteurs de neutrons intermediaires, par rapport a l'or dans le canal axial de ZOE, Cette methode permet de minimiser les erreurs dues aux sections efficaces d'activation. On decrit sommairement la salle de comptage du Service d'Etudes de Protections de Piles et on indique les caracteristiques d'emploi pratique des detecteurs utilises. (auteurs)

  18. New instruments and methods for measuring the concentration of radioactive products in the atmosphere; Appareils recents et methodes nouvelles pour la mesure de la concentration des produits radioactifs dans l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Jehanno, C; Blanc, A; Lallemant, C; Roux, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    ) [French] Differents enregistreurs pour aerosols radioactifs ont ete realises pour mesurer la pollution de l'atmosphere des laboratoires ou l'atmosphere exterieure. EAR 600. - Permet de mesurer en continu instantanement et 3 a 10 heures apres le prelevement des concentrations d'aerosols emetteurs {alpha} ou {beta} allant de quelques 10{sup -11} a quelques 10{sup -8} curies par metre cube d'air. EAR 800. - Permet de mesurer en continu des concentrations d'aerosols emetteurs {alpha} allant de 10{sup -11} a 10{sup -5} curie par metre cube d'air, et des concentrations d'aerosols emetteurs {beta} allant de 10{sup -11} a 10{sup -1} curie par metre cube d'air. EAR PLUTONIUM. - Permet de detecter en quelques minutes 1000 DMP (2.10{sup -9} curie par metre cube) et en 8 heures 1 DMP (2.10{sup -12} curie par metre cube). Deux methodes sont utilisees pour separer l'activite due au plutonium de celle due aux derives du radon et du thoron: a) par discrimination d'amplitude, b) par les coincidences (a,b) RaC' et ThC-ThC'. SP 4. - Monte sur jeep, cet ensemble permet la mesure de l'irradiation produite au sol par le panache des piles. La sensibilite est de 5{mu}R/h. A.D.I.R. - Cet appareil autonome et portatif est destine a la mesure instantanee des teneurs en radon de l'atmosphere des mines. Il permet de mesurer des teneurs de l'air variant entre 0,4 et 400.10{sup -10} curie par litre d'air (0,4 et 400 DPM). La mesure des retombees radioactives est faite apres collection de cette activite par un pluviometre special comportant une surface adhesive et une cartouche de resines echangeuses d'ions. La radioactivite des retombees varie entre quelques 10{sup -9} et quelques 10{sup -7} curie par metre carre et par mois. La mesure des concentrations de l'atmosphere en produits de fission est faite apres collection sur papier filtre. Les concentrations mesurees dans l'air au niveau du sol varient entre 10{sup -13} et 10{sup -12} curie par metre cube. (auteur)

  19. Hyperfine coupling in gadolinium-praseodymium alloys by specific heat measurements; Etude du couplage hyperfin dans les alliages gadolinium-praseodyme par mesures de chaleur specifique

    Energy Technology Data Exchange (ETDEWEB)

    Michel, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-12-01

    We have studied the hyperfine coupling in gadolinium-praseodymium alloys by specific heat measurements down to 0.3 K. In the first part we describe the apparatus used to perform our measurements. The second part is devoted to some theoretical considerations. We have studied in detail the case of praseodymium which is an exception in the rare earth series. The third part shows the results we have obtained. (author) [French] Nous avons etudie le couplage hyperfin d'alliages de gadolinium-praseodyme par des mesures de chaleur specifique jusqu'a 0.3 K. Dans la premiere partie de cette etude nous decrivons le dispositif experimental. La deuxieme partie est consacree a des considerations theoriques. Nous avons etudie en detail le cas du praseodyme qui est une exception dans la serie des terres rares. La troisieme partie est consacree aux resultats experimentaux. (auteur)

  20. Development of mercury porosimeter. Application to nuclear graphite studies (1961); Mise au point d'un porosimetre a mercure. Application a l'etude des graphites nucleaires (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Bocquet, M; Genisson, J; Sailleau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    A mercury porosimeter, model IFP-CEA, has been developed for application to nuclear graphite studies. The apparatus is based on the capillary depression phenomenon. The relationship between the radius of a pore and the pressure at which mercury fills it is pr = -2 {sigma} cos {theta} ( {sigma} is the surface tension, {theta} the angle of contact of the mercury). After some theoretical consideration, the apparatus is described. The mercury pressure is increased step-wise from 0 to 1000 kg/cm{sup 2} thus yielding the complete distribution of pores from 92 {mu} to 75 A. Results are, then presented concerning nuclear graphites which show the evolution of the porous structure under the effect of bitumen impregnation. In general, the volume of the large pores decreases while that of the small pores increases. The structure of impregnated products appears to depend to a certain extent on that of the starting materials. It has also been possible to study other products with this porosimeter; the range of measurements possible is such that it may be used for the study of the majority of porous materials. (authors) [French] Un porosimetre a mercure modele IFP-CEA a ete mis au point en vue de son application a l'etude de graphites nucleaires. Le fonctionnement de l'appareil repose sur le phenomene de depression capillaire. On etablit la relation existant entre le rayon r d'un pore et la pression p pour laquelle le mercure peut y penetrer: pr = -2 {sigma} cos {theta} ( {sigma} tension superficielle, {theta} angle de contact du mercure). Apres quelques considerations theoriques, l'appareil utilise est decrit. Il permet de faire varier par palier la pression du mercure entre 0 et 1000 kg/cm{sup 2} et d'etablir ainsi la distribution complete des rayons de pores compris entre 92 {mu} et 75 A. Les resultats d'une etude faite sur des graphites nucleaires sont alors presentes faisant apparaitre l'evolution de la structure poreuse sous l'effet des impregnations au brai. D'une facon

  1. A semi-automatic device for measuring osmotic pressures (1962); Un dispositif semi-automatique pour la mesure des pressions osmotiques (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Lucarain, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    A cryoscopic apparatus for measuring osmotic pressure in small samples (0.1 ml) is described. The sample is frozen by air cooled dry ice or liquid nitrogen; the temperature is measured by a thermistor resistance and a recording millivoltmeter. (author) [French] Un appareil cryometrique pour la mesure des pressions osmotiques sur des petits echantillons (0,1 ml) est decrit. L'echantillon est congele par une circulation d'air refroidi par de la carboglace ou de l'azote liquide; sa temperature est mesuree par une thermitance associee a un millivoltmetre enregistreur. (auteur)

  2. Activation analysis using {gamma} photons; Analyse par activation aux photons {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    This report summarizes all the data required for using photonuclear reactions in the field of analysis. After a brief review of the elementary properties of nuclear reactions induced by photon irradiation, the main characteristics are given of high energy (E > 20 MeV) Bremsstrahlung sources. The principle of activation analysis based on the use of photons is given. Actual examples of the analytic possibilities are described in detail, in particular in the case of the determination of very small quantities (< 10{sup -6}) of C, N, O and F. The influence of interfering nuclear reactions is discussed. (author) [French] Ce rapport se propose de resumer l'ensemble des connaissances indispensables pour l'utilisation des reactions photonucleaires a des fins analytiques. Apres quelques rappels concernant les proprietes elementaires des reactions nucleaires induites par irradiation dans les photons, les principales caracteristiques des sources de rayonnement de freinage de haute energie (E > 20 MeV)| sont donnees. Le principe de l'analyse par activation aux photons est rappele. Des exemples concrets sur les possibilites analytiques sont developpes, particulierement en ce qui concerne la determination de quantites tres faibles (< 10{sup -6}) de C, N, O et F. L'influence des reactions nucleaires parasites est discutee. (auteur)

  3. Measurement of radioactive isotopes by {gamma} and x rays spectrometry with INa crystals. application to radiochemistry of some fission and activation products; Mesures d'isotopes radioactifs par spectrometrie {gamma} et x a l'aide de cristaux INa. application a la radiochimie de certains produits de fission et d'activation

    Energy Technology Data Exchange (ETDEWEB)

    Simonet, P; Boile, G; Simonet, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The measurement of an number of atoms N may be obtained by detection of one {gamma} ray emitted if its branching ratio K{sub E} is known (number of E energy {gamma} transitions/number of disintegrations). N = A/{lambda} N{sub {gamma}}{sub E} / (K{sub E} * {lambda}) This measurement is effectuated in well-defined geometry, {gamma} rays emitted by the source are detected by a calibrated NaI crystal which is connected to a photomultiplier delivering electric impulses analysed by a multichannel analyser. Crystals are chosen according to energy, intensity of measured rays and of background. Calibration is established with standard sources or by total absolute efficiency of a definite crystal. Half-life, energy of measured photopeak branching ratio have been determined for these isotopes: Fission products: {sup 95}Zr, {sup 95}Nb, {sup 99}Mo, {sup 103}Ru, {sup 106}Ru, {sup 111}Ag, {sup 115}Cd, {sup 115m}Cd, {sup 132}Te, {sup 129m}Te, {sup 134}Cs, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La. Rare earth elements: {sup 91}Y, {sup 141}Ce, {sup 144}Ce, {sup 147}Nd, {sup 156}Eu. Products from reactions (n, {gamma}) (n, 2n): 1{sup 10}Ag, {sup 124}Sb, {sup 239}Np, {sup 237}U, {sup 241}Am. (authors) [French] La mesure du nombre d'atomes N d'un isotope peut s'effectuer sur un rayonnement {gamma} si l'on connait le rapport d'embranchement K{sub E} (nombre de rayonnements {gamma} d'energie E/nombre de desintegrations). N = A/{lambda} N{sub {gamma}}{sub E} / (K{sub E} * {lambda}) La mesure s'effectue en geometrie definie; les rayonnements {gamma} emis par la source sous mylar sont detectes par un cristal INa etalonne en fonction de l'energie, lequel est relie a un photomultiplicateur delivrant des impulsions electriques qui seront analysees par un selecteur multicanaux. La connaissance de la distribution theorique (effet photoelectrique, compton, paires, retrodiffusion, echappement... ) permet de determiner qualitativement si les elements sont purs, et de faire une mesure sur

  4. Measurement of the {sup 240}Pu concentration of a plutonium sample by the spontaneous fission method (1960); Mesure de la teneur d'un plutonium en {sup 240}Pu par la methode des fissions spontanees (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Caizergues, R; Clouet d' Orval, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    It is very important to know the plutonium-240 content of the plutonium formed in piles. The method of measurement described here consists in counting the number of spontaneous fissions produced in a known quantity of plutonium. This measurement is carried out in a multiple-plate ionisation chamber, the plutonium being deposited on the plates. The disintegration constant of plutonium-240 by spontaneous fission being known the plutonium-240 content in the sample can be calculated. (author) [French] La connaissance de la teneur en plutonium-240 du plutonium forme dans les piles est une question importante. La methode de mesure presentee ici consiste a compter le nombre de fissions spontanees issues d'une quantite connue de plutonium. Cette mesure est effectuee dans une chambre d'ionisation a plateaux multiples sur lesquels est depose le plutonium. La connaissance de la constante de desintegration du plutonium-240 par fissions spontanees permet de calculer la teneur en plutonium-240. (auteur)

  5. Plutonium, nuclear fuel; Le plutonium, combustible nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Grison, E [Commissariat a l' Energie Atomique, Fontenay aux Roses (France). Centre d' Etudes Nucleaires, Saclay

    1960-07-01

    A review of the physical properties of metallic plutonium, its preparation, and the alloys which it forms with the main nuclear metals. Appreciation of its future as a nuclear fuel. (author) [French] Apercu sur les proprietes physiques du plutonium metallique, sa preparation, ses alliages avec les principaux metaux nucleaires. Consideration sur son avenir en tant que combustible nucleaire. (auteur)

  6. Control of pile power by measurement of the activity of the cooling fluid. The particular case of EL3; Controle de la puissance d'une pile par la mesure de l'activite du fluide de refroidissement. Cas particulier de EL 3

    Energy Technology Data Exchange (ETDEWEB)

    Lalere, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In a high flux pile the presence of local absorbers makes the power difficult to measure. In any case thermodynamic measurements are sometimes not very accurate. Another possible method could be the measurement of the cooling fluid activity. This has been tried on the heavy water circuit of EL3. In the first part of this report we give some qualitative indications of the various activities present in the heavy water in circulation. After this, the activity of the element chosen has been calculated. Finally, the results obtained from EL3 are given. (author) [French] Dans une pile a haut flux, la presence d'absorbeurs localises rend la mesure de la puissance difficile. Les mesures thermodynamiques sont par ailleurs parfois peu precises. Un autre moyen pourrait etre la mesure de l'activite du fluide de refroidissement. C'est ce qui a ete essaye sur le circuit eau lourde de EL3. Dans une premiere partie, nous donnons quelques indications qualitatives sur les diverses activites presentes dans l'eau lourde en circulation. Ensuite, nous avons fait le calcul de l'activite de l'element choisi. Enfin, nous avons mentionne les resultats qui ont ete obtenus EL3. (auteur)

  7. Some aspects of the nuclear fission process; Quelques aspects du processus de fission nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Netter, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    In the following report one can find first a short general view on the present situation of our knowledge concerning the nuclear fission process, namely on the nucleus going through the saddle-point. Then there are some aspects connected with the excitation energy of the fissioning nucleus. The measurements made at Saclay on the fast neutron fission cross-section of U{sup 233}, U{sup 235}, Pu{sup 239}, U{sup 238} are described at the beginning of this work. It appears that for U{sup 233} there is some characteristic shape modulation of the cross-section curve, in relation with the collective excited state of the deformed nucleus at the saddle-point. Good evidence of this is also given by the study of the relative fission rate with emission of long-range particles; it appears also that this ternary fission rate does not change substantially for neutron between thermal energy and 2 MeV, but that is very lower for the compound nucleus U{sup 239} than for even-even compound nuclei. At the end there are some experiments on the strong 4,5 MeV gamma-ray originated by slow neutron absorption in U{sup 235}. Time-of-flight device is used to establish that this 4,5 MeV gamma-ray seems mostly connected with radiative capture. (author) [French] Le present travail debute par un apercu de l'etat actuel de nos connaissances sur le processus de fission nucleaire, notamment sur le passage par le point-seuil. Puis sont evoques des aspects lies au niveau d'energie d'excitation auquel est porte le noyau qui subit la fission. Les mesures de sections efficaces de fission induite dans {sup 233}U, {sup 235}U, {sup 239}Pu et {sup 238}U par des neutrons rapides effectuees a Saclay sont decrites en premier lieu; elles font apparaitre pour {sup 233}U une ondulation caracteristique du role des etats collectifs d'excitation du noyau deforme au point-seuil. Des experiences sur la fission avec emission de particules de long parcours confirment cet aspect tout en demontrant que la frequence

  8. Argon activation analysis, application to dating by the potassium-argon method; Analyse par activation de l'argon. Application a la datation par la methode potassium-argon

    Energy Technology Data Exchange (ETDEWEB)

    Dumesnil, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Activation analysis using radiogenic argon-40 has been applied to rock-dating by the K-Ar method. The argon is extracted from the sample, purified, activated to saturation in a flux of 2 X 10{sup 13} neutrons/cm{sup 2} sec{sup -1} and measured by gamma spectroscopy. The sensitivity obtained is such that it is possible to measure amounts of argon corresponding to age of a few thousand years only. However since it has not been possible to measure the amount of pollution of radiogenic argon by atmospheric argon with any accuracy, the measurable age limit is in fact of the order of MY. The method has been applied to basalts from the Mont-Dore region. The results obtained are in fairly good agreement with geological, stratigraphic and paleomagnetic data. (author) [French] L'analyse par activation de l'argon 40 radiogenique a ete appliquee a la datation des roches par la methode K-Ar. L'argon est extrait de l'echantillon, purifie, active a saturation dans un flux de 2.10{sup 13} neutrons.cm{sup -2}.s{sup -1} et mesure en spectrometrie gamma. La sensibilite obtenue est telle qu'il est possible de mesurer des quantites d'argon correspondant a des ages de quelques milliers d'annees seulement. Cependant la correction de pollution de l'argon radiogenique par l'argon atmospherique n'ayant pu etre etablie avec precision, la limite d'age mesurable pratique est de l'ordre de 1 Ma. La methode a ete appliquee aux basaltes de la region du Mont-Dore. Les ages obtenus sont en assez bon accord avec les donnees geologiques, stratigraphiques et paleomagnetiques. (auteur)

  9. Etude de la performance des radars hautes-frequences CODAR et WERA pour la mesure des courants marins en presence partielle de glace de mer

    Science.gov (United States)

    Kamli, Emna

    Les radars hautes-frequences (RHF) mesurent les courants marins de surface avec une portee pouvant atteindre 200 kilometres et une resolution de l'ordre du kilometre. Cette etude a pour but de caracteriser la performance des RHF, en terme de couverture spatiale, pour la mesure des courants de surface en presence partielle de glace de mer. Pour ce faire, les mesures des courants de deux radars de type CODAR sur la rive sud de l'estuaire maritime du Saint-Laurent, et d'un radar de type WERA sur la rive nord, prises pendant l'hiver 2013, ont ete utilisees. Dans un premier temps, l'aire moyenne journaliere de la zone ou les courants sont mesures par chaque radar a ete comparee a l'energie des vagues de Bragg calculee a partir des donnees brutes d'acceleration fournies par une bouee mouillee dans la zone couverte par les radars. La couverture des CODARs est dependante de la densite d'energie de Bragg, alors que la couverture du WERA y est pratiquement insensible. Un modele de fetch appele GENER a ete force par la vitesse du vent predite par le modele GEM d'Environnement Canada pour estimer la hauteur significative ainsi que la periode modale des vagues. A partir de ces parametres, la densite d'energie des vagues de Bragg a ete evaluee pendant l'hiver a l'aide du spectre theorique de Bretschneider. Ces resultats permettent d'etablir la couverture normale de chaque radar en absence de glace de mer. La concentration de glace de mer, predite par le systeme canadien operationnel de prevision glace-ocean, a ete moyennee sur les differents fetchs du vent selon la direction moyenne journaliere des vagues predites par GENER. Dans un deuxieme temps, la relation entre le ratio des couvertures journalieres obtenues pendant l'hiver 2013 et des couvertures normales de chaque radar d'une part, et la concentration moyenne journaliere de glace de mer d'autre part, a ete etablie. Le ratio des couvertures decroit avec l'augmentation de la concentration de glace de mer pour les deux types

  10. Mesure de la teneur en eau en continu durant le séchage du foin en balles

    OpenAIRE

    Cormier, Étienne

    2008-01-01

    Une mesure en continu et précise de la teneur en eau (TEE) permettrait d'optimiser le séchage du foin dans un séchoir commercial à grande échelle. Pour mesurer la précision des lectures dans ces conditions, un capteur électronique relié à 16 sondes a été utilisé pour estimer la TEE dans un séchoir expérimental. Deux sondes et un thermocouple étaient insérés dans huit couches de foin superposées, de 135 mm d'épaisseur chacune. Les TEE estimées par les sondes ont été comparées à des TEE exactes...

  11. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  12. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  13. Comprehensive measurements in 4 {pi} geometry for radio-active samples having a low {beta}-activity (1962); Ensemble de mesure'en geometrie 4 {pi} pour echantillons radioactifs de faible activite {beta} (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Colomer, J; Valentin, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The realisation is described of a comprehensive measurement system having low background noise and, as well as a lead-wall protection, an electronic protection made up of a plastic scintillator placed in anticoincidence with the 4 {pi} counter used for making the measurements. The apparatus is described and its performance discussed. (authors) [French] Realisation d'un ensemble de mesures ayant un faible bruit de fond en utilisant en plus d'une protection par murs de Pb, une protection electronique constituee par un scintillateur plastique mis en ainticoincidence avec le compteur 4 {pi} utilise pour faire les mesures. L'appareillage est decrit et ses performances discutees. (auteurs)

  14. An instrument for measuring doubling time; Un appareillage de mesure de temps de doublement

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Chandanson, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    The instrument described here allows the direct and almost immediate measurement, with a precision of the order of 1 per cent, of the time taken by a reactor to double its power. The method of measurement consists of noting the instants when the power of the reactor passes the levels P{sub 1} and P{sub 2} such that P{sub 2} = 2 P{sub 1}, and of measuring the time lapse between these two instants. The instrument picks out, in the course of one rise in power, several levels, P{sub 1}, P{sub 2}, P{sub 3}... etc, chosen in such a manner as to give several successive measurements of the doubling time. It is also capable of making these same measurements when the reactor is working below the critical level. (author) [French] L'appareil decrit ici permet la mesure directe et quasi immediate du temps de doublement de la puissance d'un reacteur avec une precision de l'ordre de 1 pour cent. La methode de mesure consiste a reperer les instants de passage de la puissance du reacteur par des niveaux P{sub 1} et P{sub 2} tels que P{sub 2} = 2 P{sub 1}, et a mesurer le temps ecoule entre ces deux instants. L'appareil repere, au cours d'une meme montee en puissance, plusieurs niveaux, P{sub 1}, P{sub 2}, P{sub 3}... etc, choisis de maniere a donner plusieurs mesures successives du temps de doublement. Il est egalement utilisable pour effectuer ces memes mesures lorsque le reacteur est en regime sous-critique. (auteur)

  15. Les fondements de la mesure du temps comment les fréquences atomiques règlent le monde

    CERN Document Server

    Audoin, Claude

    1998-01-01

    La mesure du temps fondée sur des propriétés atomiques est née en 1955, avec le premier étalon de fréquence à jet de césium. Depuis, les horloges atomiques ne cessent de progresser et sont au coeur de nombreuses activités, telles que les comparaisons de temps, l'unification mondiale de l'heure ou la recherche en astronomie, géodésie, géophysique, télécommunications, etc. Cet ouvrage fournira des réponses détaillées au lecteur intéressé par la mesure du temps appliquée aux divers domaines cités.

  16. New developments in the analysis and measurement of thicknesses by excitation of the fluorescent lines by means of {beta} particles; Nouveaux developpements de l'analyse et de la mesure des epaisseurs par excitation des raies de fluorescence au moyen de particules {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Seibel, G [Institut de Recherches de la Siderurgie, 78 - Saint-Germain-en-Laye (France)

    1960-07-01

    The process for analysing and measuring the thickness of deposits by {beta}-X fluorescence which we have already described has undergone further development. The use of promethium-147 and krypton-85 sources makes it possible to reduce the background noise which is observed with strontium-90. We present the results obtained for various measurements of the thickness of metallic coatings and the continuous measurement of calcium and of iron in ore samples. We describe the tests carried out with a view to analysing the X-rays by means of a crystal. (author) [French] Le procede d'analyse et de mesure des epaisseurs de depots par fluorescence {beta}-X que nous avons precedemment decrit a fait l'objet de nouveaux developpements. L'emploi de sources de prometheum-147 et de krypton-85 permet de reduire le bruit de fond que l'on observe avec le strontium-90. Nous dormons les resultats obtenus pour diverses mesures d'epaisseurs de depots metalliques et la mesure en continu du calcium et du fer dans les carottes de minerais. Nous decrivons les essais effectues en vue d'analyser le rayonnement X au moyen d'un cristal. (auteur)

  17. Production of nuclear graphite in France; Production de graphite nucleaire en France

    Energy Technology Data Exchange (ETDEWEB)

    Legendre, P; Mondet, L [Societe Pechiney, 74 - Chedde (France); Arragon, Ph; Cornuault, P; Gueron, J; Hering, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The graphite intended for the construction of the reactors is obtained by the usual process: confection of a cake from coke of oil and tar, cooked (in a electric oven) then the product of cook is graphitized, also by electric heating. The use of the air transportation and the control of conditions cooking and graphitization have permitted to increase the nuclear graphite production as well as to better control their physical and mechanical properties and to reduce to the minimum the unwanted stains. (M.B.) [French] Le graphite destine a la construction des reacteurs est obtenu par le procede usuel: confection d'une pate a partir de coke de petrole et de brai, cuisson de cette pate (au four electrique) puis graphitation du produit cuit, egalement par chauffage electrique. L'usage du transport pneumatique et le controle des conditions cuisson et de graphitation ont permit d'augmenter la production de graphite nucleaire ainsi que de mieux controler ses proprietes physiques et mecaniques et de reduire au minimum les souillures accidentelles. (M.B.)

  18. Adiabatic calorimeter with static vacuum for the measurement of the heating of in- pile materials; Calorimetre adiabatique a vide statique pour la mesure d'echauffements de materiaux en pile

    Energy Technology Data Exchange (ETDEWEB)

    Brun, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    After having reviewed the various interaction processes occurring between radiations present in nuclear reactors and matter, the author describes the different calorimetric methods which may be used for measuring the energy absorbed in the materials. He then gives a detailed description of the adiabatic calorimeter, the associated measurement device and the calibration methods which have been chosen. He finally gives values for the heating produced at various experimental positions in the reactors EL-2 and EL-3 for several materials currently used in reactor construction. (author) [French] Apres avoir passe en revue les differents processus d'interaction des rayonnements, existant dans les reacteurs nucleaires, avec la matiere, l'auteur decrit les differentes methodes calorimetriques qui peuvent etre utilisees pour mesurer l'energie absorbee dans les materiaux. II presente ensuite en detail le calorimetre adiabatique, le dispositif de mesure associe et les methodes d'etalonnage qui ont ete retenus. Enfin il donne des valeurs d'echauffement dans divers emplacements experimentaux des piles EL-2 et EL-3 pour differents materiaux d'utilisation courante dans les reacteurs. (auteur)

  19. Measurement and Overall Characterization of Permeability Anisotropy by Tracer Injection Mesure et caractérisation globale de léanisotropie de perméabilité par injection de traceurs

    Directory of Open Access Journals (Sweden)

    Bieber M. T.

    2006-11-01

    polynomial approximation, the experimental data are inverted in terms of the permeability tensor, using a method analogous to the one developed at Institut Français du Pétrole (IFP for inverting the elasticity tensor. We will show an example based on a real reservoir case before concluding with a discussion of the applicability of this method to other scales of observation. Les roches réservoir peuvent présenter une très forte anisotropie de perméabilité (K. Les méthodes classiques de mesure de cette anisotropie, consistant à prélever dans la même carotte plusieurs éprouvettes d'axes différemment orientés ou à faire les mesures sur des échantillons de forme particulière, ne permettent généralement pas de définir totalement l'anisotropie de perméabilité. Nous avons développé une méthode simple et globale de mesure et de caractérisation de cette anisotropie. Si, en un point d'un milieu poreux, perméable, infini, saturé totalement d'un fluide peu compressible, l'on injecte un deuxième fluide parfaitement miscible au premier et de même densité, l'interface entre ces deux fluides (front d'invasion dessine une surface telle que, à un instant donné, la distance du point d'injection à la surface soit proportionnelle à la racine carrée de K dans la direction considérée. Il suffit de décrire les caractéristiques géométriques d'un front d'invasion lors d'un déplacement miscible à partir d'une injection ponctuelle et de mesurer une seule valeur absolue de perméabilité pour quantifier globalement la perméabilité du milieu. La méthode proposée consiste à injecter dans une roche préalablement saturée de saumure, une solution de sel absorbant les rayons X (KI par exemple dont nous suivons aisément le front d'invasion par tomographie X. La validation de la méthode est basée sur la vérification expérimentale de l'absence de perturbation liée à la diffusion ionique, de l'insensibilité du résultat aux paramètres d'injection et de l

  20. Plutonium separation and the measurement of its concentration in natural waters (1963); Separation du plutonium et mesure de sa concentration dans les eaux naturelles

    Energy Technology Data Exchange (ETDEWEB)

    Scheidhauer, J; Messainguiral, L; Meiraneisio, A M [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1963-07-01

    After concentration by chemisorption on a calcium fluoride suspension, the plutonium is purified and isolated by xylene extraction of the complex formed with T.T.A. The radioelement is measured by counting with a ZnS (Ag) scintillator after evaporation or electrolysis. (authors) [French] Apres concentration par chimisorption sur une suspension de fluorure de calcium, le plutonium est purifie et isole par extraction au xylene du complexe forme avec la T.T.A. La mesure du radioelement est effectuee par comptage au scintillateur S Zn (Ag) apres evaporation ou electrolyse. (auteurs)

  1. Contribution to the study of nuclear structure using neutron total cross-section measurements between 400 and 1200 keV: isolated resonances and intermediate structure; Contribution a l'etude de la structure nucleaire par des mesures de sections efficaces neutroniques entre 400 keV et 1200 keV. Resonances isolees et structure intermediaire

    Energy Technology Data Exchange (ETDEWEB)

    Cabe, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-15

    The neutron total cross sections have been measured over the energy range 400 keV - 1200 keV for fluorine, aluminium, silicon, phosphorus, vanadium, chromium, manganese, iron, nickel, cobalt and lead with an energy spread of 3 keV. The neutrons were produced by the T (p,n) {sup 3}He reaction, the proton beam was supplied by a 2 MeV Van de Graaff. The structure in {sup 56}Fe has been studied in a more detailed way by measuring six angular distributions in the above range and the elastic scattering excitation curves at four angles. The measurements have made it possible to show the existence of the compound nucleus, as well as the presence of an intermediate structure in certain nuclei. (author) [French] Nous avons mesure les sections efficaces totales neutroniques entre 400 keV et 1200 keV du fluor, de l'aluminium, du silicium, du phosphore, du vanadium, du chrome, du manganese, du fer, du nickel, du cobalt et du plomb avec une dispersion en energie de 3 keV. Les neutrons etaient produits a l'aide de la reaction T (p,n) {sup 3}He, les protons etant acceleres par un Van de Graaff 2 MeV. Nous presentons de plus quatre courbes d'excitation de la diffusion elastique des neutrons sur le fer ainsi que six distributions angulaires. Ces mesures ont permis de mettre en evidence un certain nombres de resonances du noyau compose, ainsi que la presence d'une structure intermediaire dans. certains noyaux. (auteur)

  2. Automatic device for measuring {beta}-emitting sources: P.A.P.A. {beta}-meters; Dispositif automatique pour la mesure de sources emettrices de rayonnement {beta}: P.A.P.A. {beta} metres

    Energy Technology Data Exchange (ETDEWEB)

    Colomer, J; Valentin, M [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The apparatus described is designed for measuring {beta}-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a {beta}-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [French] L'appareillage decrit est destine aux mesures des elements emetteurs {beta} par la methode d'absorption et il permet d'effectuer, en routine, un nombre important de mesures. Un ensemble mecanique effectue le passage automatique, sous vide primaire, d'un jeu d'absorption en aluminium entre la source et le detecteur, ce passage est programme en pre-temps ou pre-coup par un ensemble electronique a transistors, avec impression et perforation sur bandes des resultats des mesures pour traitement mathematique par un ordinateur (trace du spectre d'absorption, extrapolation et calcul d'activite). Le detecteur est soit une sonde {beta}, soit un compteur proportionnel a boucle specialement realise. Sur des mesures de routine, la precision obtenue, toutes corrections effectuees, est de 5 a 8 pour cent et la reproductibilite de l'ordre de 2 pour cent. (auteur)

  3. Nuclear magnetic resonance of iron-57 nuclei in local fields in yttrium and iron garnets; Resonance magnetique nucleaire des noyaux du fer 57 dans les champs locaux du grenat d'yttrium et de fer

    Energy Technology Data Exchange (ETDEWEB)

    Robert, C. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    We have demonstrated the nuclear resonance of {sup 57}Fe nuclei in the local field of each of the two magnetic sub-lattices of yttrium and iron garnets. The resonance frequencies and the relaxation times have been measured as a function of the temperature. (author) [French] Nous avons mis en evidence la resonance nucleaire des noyaux de {sup 57}Fe dans le champ local de chacun des deux sous-reseaux magnetiques du grenat d'yttrium et de fer. Les frequences de resonances et les temps de relaxation ont ete mesures en fonction de la temperature. (auteur)

  4. Contribution to the study and use of ionisation chambers for nuclear reactor control (1965); Contribution a l'etude et a l'utilisation des chambres d'ionisation pour le controle des reacteurs nucleaires (1965)

    Energy Technology Data Exchange (ETDEWEB)

    Duchene, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    high-power reactors. (author) [French] Les chambres d'ionisation sont actuellement les detecteurs les mieux adaptes au controle des reacteurs nucleaires par des mesures neutroniques. Nous avons cru bon de rappeler quelques generalites concernant la dynamique des reacteurs, les differents procedes de detection des neutrons, le fonctionnement des chambres d'ionisation et les methodes de mesure utilisees. Notre contribution aux techniques de controle des reacteurs consiste d'une part en une tentative de synthese des facteurs intervenant dans le fonctionnement des chambres d'ionisation, l'etude de ces facteurs, et d'autre part l'elaboration de chambres d'ionisation a fission et a bore permettant de suivre la marche d'un reacteur du demarrage jusqu'a la puissance maximale. Dans le domaine des chambres a fission, nous avons en particulier ameliore les techniques de depot d'oxyde d'uranium sur l'aluminium et realise la mise au point de depots par electrolyse sur d'autres metaux: acier inoxydable, cuivre, molybdene, nickel, tantale, titane, kovar, tungstene et beryllium. Nous avons elabore plusieurs types de chambres a fission servant au demarrage des reacteurs: un type de performances moyennes actuellement utilise dans les piles francaises un type a haute sensibilite un type a haute temperature qui a fonctionne jusqu'a 600 deg. C. En ce qui concerne les chambres a bore, nous avons etudie les perturbations apportees dans les mesures par l'exposition des chambres a d'importants flux de neutrons et a un rayonnement {gamma} intense. Cette exposition produit une modification des proprietes des materiaux constitutifs et la production dans les chambres d'un bruit de fond qui peut gener considerablement les mesures neutroniques. Nous avons montre que la technique de compensation permettait de limiter l'importance de ce bruit de fond et d'augmenter ainsi la plage de fonctionnement des chambres d'ionisation classiques destinees aux mesures de puissance. Enfin, nous avons realise deux

  5. Treatment of effluent at the Saclay Centre d'Etudes Nucleaires (1960); Le traitement des effluents du Centre d'Etudes Nucleaires de Saclay (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The Centre d'Etudes Nucleaires at Saclay possesses several installations from which liquid radioactive effluent is rejected, and it has thus been found necessary to construct a station for the purification of radioactive liquids and to settle various chemical, analytical and technological problems. This report describes, in the following order: - the disposal possibilities at the Centre d'Etudes Nucleaires, Saclay, - the effluents produced at the centre, - the set-up for collecting effluent, - treatment of the effluent, - results of these treatments. (author) [French] La presence, au Centre d'Etudes Nucleaires de Saclay, de plusieurs installations susceptibles de rejeter des effluents liquides radioactifs a necessite la construction d'une station d'epuration d'eaux radioactives et la mise au point de differents problemes chimiques, analytiques et technologiques. Dans ce rapport, nous exposerons successivement: - les possibilites de rejet du Centre d'Etudes Nucleaires de Saclay, - les effluents du centre, - le dispositif de collecte des effluents, - le traitement de ces effluents, - les resultats de ces traitements. (auteur)

  6. Argon activation analysis, application to dating by the potassium-argon method; Analyse par activation de l'argon. Application a la datation par la methode potassium-argon

    Energy Technology Data Exchange (ETDEWEB)

    Dumesnil, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Activation analysis using radiogenic argon-40 has been applied to rock-dating by the K-Ar method. The argon is extracted from the sample, purified, activated to saturation in a flux of 2 X 10{sup 13} neutrons/cm{sup 2} sec{sup -1} and measured by gamma spectroscopy. The sensitivity obtained is such that it is possible to measure amounts of argon corresponding to age of a few thousand years only. However since it has not been possible to measure the amount of pollution of radiogenic argon by atmospheric argon with any accuracy, the measurable age limit is in fact of the order of MY. The method has been applied to basalts from the Mont-Dore region. The results obtained are in fairly good agreement with geological, stratigraphic and paleomagnetic data. (author) [French] L'analyse par activation de l'argon 40 radiogenique a ete appliquee a la datation des roches par la methode K-Ar. L'argon est extrait de l'echantillon, purifie, active a saturation dans un flux de 2.10{sup 13} neutrons.cm{sup -2}.s{sup -1} et mesure en spectrometrie gamma. La sensibilite obtenue est telle qu'il est possible de mesurer des quantites d'argon correspondant a des ages de quelques milliers d'annees seulement. Cependant la correction de pollution de l'argon radiogenique par l'argon atmospherique n'ayant pu etre etablie avec precision, la limite d'age mesurable pratique est de l'ordre de 1 Ma. La methode a ete appliquee aux basaltes de la region du Mont-Dore. Les ages obtenus sont en assez bon accord avec les donnees geologiques, stratigraphiques et paleomagnetiques. (auteur)

  7. Evolution of nuclear chemical industry in France; Evolution de l'industrie chimique nucleaire en France

    Energy Technology Data Exchange (ETDEWEB)

    Fould, M H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    'impulsion du CEA, mais aussi de maitres d'oeuvres tels qu'Electricite de France et la Marine Marchande, l'effort nucleaire fran is atteint pour les annees 1957-1961, environ 600 milliards de francs: plus de la moitie de cette somme sera depensee par l'industrie chimique en recherches, installations pilotes, constructions d'usines et livraisons. Faire bien, vite et rentable sont les buts recherches. Ces objectifs sont atteints grace a une collaboration intime des grands services de l'etat et de l'industrie privee. Ce gros effort s'exerce principalement dans les voies suivantes: - Un traitement chimique pousse de tonnages croissants des minerais de l'Union fran ise, visant a produire un uranium pur, abondant et bon marche. - Une preparation soigneuse de combustibles nucleaires economiques et parfaitement adaptes aux divers types de reacteurs en fonctionnement ou en construction. - Un retraitement des combustibles irradies pour en extraire le plutonium de facon complete ainsi que l'uranium et certains produits de fission. - Une fabrication industrielle des materiaux nucleairement purs ou resistants a la corrosion exiges par la technologie des reacteurs producteurs d'energie et de recherches. - La fourniture aux multiples utilisateurs etrangers et fran is d'isotopes et de traceurs radioactifs reclames par la medecine, l'industrie et l'agriculture en nombre toujours croissant. - Un traitement chimique meticuleux des effluents gazeux ou liquides dans des stations au controle rigoureux afin de rendre les reacteurs et leurs annexes parfaitement surs d'emploi. Cet expose aura montre l'ampleur de l'effort deploye par une industrie chimique nucleaire jeune, dynamique et en plein essor. Ayant assure ses techniques, realise de nombreuses installations, elle est largement en etat de faire face au programme atomique fran is. En outre, elle est capable et desireuse d'etre associee aux developpements de l'industrie atomique etrangere notamment dans te cadre de l'Euratom et d

  8. Determination of the concentration of {alpha} emitting radioactive aerosols; Mesure de la concentration des aerosols radioactifs emetteurs {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Labeyrie, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-06-15

    In the first part of this work the techniques used for the quantitative measurement of the concentrations of aerosols carrying short lived (radon or thoron daughters) or long lived (uranium) {alpha} radioactive emitters are described. In the second part the author investigates the problem of the determination of radon concentration in air by means of activity determinations on airborne dusts. Special reference is made to the measurement of the radon active deposit on two types of dusts (iron oxide (yellow) and uranium oxide) in small chambers (6 liters). In the third part are given data resulting from determinations of radon and thoron concentrations in atmospheric air in the south of Paris area using this method. (author) [French] Dans la premiere partie de ce travail on expose les techniques utilisees pour la mesure quantitative des concentrations d'aerosols contenant des emetteurs radioactifs {alpha}, tant pour ceux a vie courte (derives du radon ou du thoron) que pour ceux a vie longue (uranium). Dans la seconde partie on traite le probleme de la determination de la concentration de l'air en radon par la mesure de l'activite des poussieres ayant sejourne dans cet air. En particulier, on indique pour de petits volumes (6 litres) la proportion de depot actif du radon qui est fixee sur deux types de poussieres (limonite et oxyde d'uranium) en fonction de la concentration de celles-ci. Dans la troisieme partie on donne quelques exemples de mesure par cette methode de la concentration en radon et en thoron de l'atmosphere de la region parisienne. (auteur)

  9. Induction of the lambda bacteriophage synthesis in Escherichia coli K 12 by polonium alpha rays; Induction de la synthese du bacteriophage lambda chez Escherichia coli K 12 par les rayons alpha du polonium

    Energy Technology Data Exchange (ETDEWEB)

    Devoret, Raymond

    1958-06-15

    This research thesis reports the study of the inducing action of polonium alpha radiations in Escherichia Coli K 12 by using an external irradiation device. This work comprised the development of a method to spread bacteria in layer with a thickness less than 20 microns, and the measurement of the number of α particles falling on the irradiated surface. This measurement has been performed by using a nuclear emulsion and a simple photographic film. It appears that alpha radiations have an inducing action, and that at most 15 per cent of bacteria can be induced. The comparison of the induction curve with the survival curves of lysogen and sensitive stains shows that there is no abortive induction. Thus, it appears that this inducing action is not due to an indirect effect of the irradiated medium [French] Dans ce travail on a etudie l'action inductrice des rayons alphas du polonium chez Escherichia Coli K 12 par un diapoaitif d'irradiation externe. Son utilisation necessitait: - une methode d'etalement des bacteries en couche de moins de 20 microns d'epaisseur; - une mesure du nombre des particules alpha tombant sur la surface etendue irradiee. Les mesures ont ete faites a l'aide d'une emulsion nucleaire et d'un film photographique ordinaire. 1) Les rayons alphas ont une action inductrice. Au plus 15 pc des bacteries peuvent etre induites. 2) La oomparaison de la courbe d'induction et des courbes de survie des souches lysogene et sensible montre qu'il n'y a pas d'inductions abortives. 3) Cette action inductrice n'est pas due a un effet indirect du milieu irradie. (auteur)

  10. Limit to the measurement of feeble activities using ionization chambers; Limite des possibilites de mesure de faibles activites au moyen de chambres d'ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Briere, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The present account based on experience acquired in the Biology Service, in measuring feeble activities of tritium and carbon-14 has been prepared for the benefit hose who have to carry out measurements of feeble activities using ionization chambers. Precision are given on the behaviour and actual performance of vibrating condenser electrometers, based on approximately two years operating experience. It is shown that the possibilities of utilisation are not limited as is generally believed by insufficient sensitivity and stability of the electronic equipment, but by the existence of various parasitic phenomena coming from the ionization chamber itself, which make very difficult the measurement of ionization currents which are less than 10{sup -14} A. (author)Fren. [French] Le present compte rendu, base sur l'experience acquise au Service de Biologie dans la mesure de faibles activites de tritium et de carbone-14, est redige a l'intention des personnes ayant a effectuer des mesures de tres faibles activites au moyen de chambres d'ionisation. Il donne des precisions sur le comportement et les performances reelles des electrometres a condensateur vibrant, basees sur environ deux ans d'utilisation, et demontre que les possibilites de mesure ne sont pas limitees - comme on le croit generalement - par l'insuffisance de sensibilite et de stabilite de l'appareillage electronique, mais par l'existence de divers phenomenes parasites dont la chambre d'ionisation est le siege et qui rendent tres difficiles la mesure de courants d'ionisation inferieurs a 10{sup -14} A. (auteur)

  11. Relationship between the nuclear resonance of cobalt metal and its ferromagnetic properties; Relations entre la resonance nucleaire du cobalt metallique et ses proprietes ferromagnetiques

    Energy Technology Data Exchange (ETDEWEB)

    Aubrun, J.N. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-05-15

    resulte du couplage intense existant entre les noyaux et les electrons porteurs du magnetisme. Ces derniers excitent les noyaux et, dans les parois de Bloch, les soumettent a un champ radio-frequence bien plus intense que le champ RF applique. Les parametres de la resonance se determinent alors a partir du mouvement des parois, et dependent donc des constantes ferromagnetiques. La theorie permet de prevoir quantitativement certains effets particuliers, notamment par action d'un champ magnetique continu ou de la temperature. L'etude expeimentale a porte sur des poudres de cobalt et est en bon accord avec la theorie. Toutefois il faut tenir compte de l'effet de peau et reviser la theorie en consequence. Ceci permet d'expliquer certaines divergences observees, ainsi que l'influence de la taille des grains et celle du champ magnetique sur la forme de raie. Des renseignements originaux ont ete obtenus sur certaines proprietes purement ferromagnetiques du cobalt, en etudiant l'effet d'un champ magnetique et cette methode a pu etre appliquee a d'autres corps ferromagnetiques. En raison du caractere particulier de cette resonance nucleaire, qui se produit en l'absence de champ directeur et possede une importante largeur de raie, des spectrographes de type nouveau ont ete realises qui ont rendu possible des mesures precises de la forme de raie. La faible intensite des signaux obtenus dans certains cas a conduit a la mise au point d'une methode originale d'extraction dont la theorie et les applications pratiques sont donnees ici. L'ensemble de ces experiences fait apparaitre la resonance nucleaire comme un puissant moyen d'etude du ferromagnetique permettant de deceler des phenomenes microscopiques difficilement accessibles par les methodes classiques. (auteur)

  12. Relationship between the nuclear resonance of cobalt metal and its ferromagnetic properties; Relations entre la resonance nucleaire du cobalt metallique et ses proprietes ferromagnetiques

    Energy Technology Data Exchange (ETDEWEB)

    Aubrun, J N [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-05-15

    couplage intense existant entre les noyaux et les electrons porteurs du magnetisme. Ces derniers excitent les noyaux et, dans les parois de Bloch, les soumettent a un champ radio-frequence bien plus intense que le champ RF applique. Les parametres de la resonance se determinent alors a partir du mouvement des parois, et dependent donc des constantes ferromagnetiques. La theorie permet de prevoir quantitativement certains effets particuliers, notamment par action d'un champ magnetique continu ou de la temperature. L'etude expeimentale a porte sur des poudres de cobalt et est en bon accord avec la theorie. Toutefois il faut tenir compte de l'effet de peau et reviser la theorie en consequence. Ceci permet d'expliquer certaines divergences observees, ainsi que l'influence de la taille des grains et celle du champ magnetique sur la forme de raie. Des renseignements originaux ont ete obtenus sur certaines proprietes purement ferromagnetiques du cobalt, en etudiant l'effet d'un champ magnetique et cette methode a pu etre appliquee a d'autres corps ferromagnetiques. En raison du caractere particulier de cette resonance nucleaire, qui se produit en l'absence de champ directeur et possede une importante largeur de raie, des spectrographes de type nouveau ont ete realises qui ont rendu possible des mesures precises de la forme de raie. La faible intensite des signaux obtenus dans certains cas a conduit a la mise au point d'une methode originale d'extraction dont la theorie et les applications pratiques sont donnees ici. L'ensemble de ces experiences fait apparaitre la resonance nucleaire comme un puissant moyen d'etude du ferromagnetique permettant de deceler des phenomenes microscopiques difficilement accessibles par les methodes classiques. (auteur)

  13. L'obtention du crédit bancaire par les PME au Cameroun

    African Journals Online (AJOL)

    Doctorante en sciences de gestion Université de Ngaoundéré, Cameroun. .... vient à point nommé dans son contexte et dans son domaine dans la mesure ... confrontant la performance des entreprises à leur structure financière, Wanda ..... est le plus souvent la perte du contrôle de l'entreprise par les actionnaires.

  14. Calculation of the shock-wave in the region close to an underground nuclear explosion (method Cades); Calcul de l'onde de choc en zone proche d'une explosion nucleaire souterraine (methode cades)

    Energy Technology Data Exchange (ETDEWEB)

    Supiot, F; Brugies, J [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The outline of a method is presented for calculating the characteristics of a shock wave produced by an underground nuclear explosion (pressure, wave velocity, velocity of the medium, energy left in the medium by the shock, etc.). By means of an application to a granitic medium and of a comparison with results obtained during French nuclear explosions, it has been possible to show the good agreement existing between the calculations and the experimental results. The advantages of such a method for studying the industrial applications of underground nuclear explosions are stressed. (authors) [French] On expose les grandes lignes d'une methode de calcul des caracteristiques de l'onde de choc issue d'une explosion nucleaire souterraine (pression, vitesse de l'onde, vitesse du milieu, energie deposee par le choc dans le milieu...). Une application a un milieu granitique et une comparaison aux resultats obtenus au cours d'explosions nucleaires francaises permet de montrer la bonne concordance entre le calcul et les resultats experimentaux. On souligne l'interet d'une telle, methode pour l'etude d'applications industrielles des explosions nucleaires souterraines. (auteurs)

  15. Direct interaction in nuclear reactions: a theory; L'interaction directe dans les reactions nucleaires: theorie

    Energy Technology Data Exchange (ETDEWEB)

    Dominicis, C.T. de [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    General treatment of the foundations of direct interaction in nuclear reactions; representation of the instantaneous elastic scattering amplitude by the scattering amplitude due to a complex potential; expansion of the instantaneous inelastic scattering amplitude and discussion of the 1. Bohr approximation (distorted waves) contribution to individual and collective states of excitation. (author) [French] Expose general sur les fondements de l'interaction directe dans les reactions nucleaires; representation de l'amplitude de diffusion instantanee elastique par celle due a un potentiel complexe; developpement de l'amplitude de diffusion instantanee inelastique et discussion de la contribution de la premiere approximation de Bohr (sur des distendues) a l'excitation d'etats individuels et collectifs. (auteur)

  16. Pollution odorante par les moteurs Diesel. Mesure des odeurs d'échappement Odorous Pollution by Diesel Engines. Measuring Exhaust Odors

    Directory of Open Access Journals (Sweden)

    Degobert P.

    2006-11-01

    Full Text Available Les études de mesure d'odeur Diesel ont commencé en 1956 aux États-Unis, en particulier pour réduire le niveau odorant des autobus. Cet article expose d'abord les mécanismes de formation des odorants puis les études américaines, qui ont abouti en 1973 à l'odorimètre Arthur D. Little, basé sur l'analyse par chromatographie liquide de l'échappement, et ses corrélations avec les données sensorielles recueillies dans des conditions particulières. Les économies d'énergie dans les villes européennes entraînent un accroissement du nombre de véhicules Diesel, ce qui peut amener un niveau odorant incompatible avec le bien-être. C'est pourquoi l'Institut Français du Pétrole (IFP étudie actuellement les odeurs Diesel, pour mettre au point des méthodes de mesure fiables, partant de la chromatographie liquide type Arthur D. Little (ADL et de l'évaluation sensorielle. Les résultats actuels montrent qu'à moins de progrès importants en analyse chimique, l'évaluation sensorielle reste la méthode la plus fiable. Les perspectives futures basées sur l'olfactomètre différentiel Mac Leod sont présentées. Research was beg un in the United States in 1956 on the medsurementof diesel engine odors, and especially on reducing the odor from diesel city buses. This article begins by describing the mechanisms of odor formation and then goes on ta, review US research which resulted in the Arthur D. Little odormeter in 1973, based on a liquid chromatography analysis of exhaust and its corrélations with sensory data gathered under specific conditions. Energy conservation in European cities is tending ta, increase the number of diesel vehicles and possibly ta, create an odor level that is incompatible with humal well-being. This is why Institut Français du Pétrole (IFP is now investigating diesel eng ine odors for the purpose of developing reliable measuring methods based on liquid chromatography of the Arthur D. Little (ADl type and on

  17. Mesure de la masse volumique des particules des eaux résiduaires urbaines : protocole et évaluation des incertitudes

    OpenAIRE

    RUBAN, Gwenaël; LABORATOIRE CENTRAL DES PONTS ET CHAUSSEES - LCPC

    2004-01-01

    La connaissance de la masse volumique des particules des eaux résiduaires urbaines est intéressante notamment pour l'étude de leur traitement par décantation ainsi que des relations entre concentrations en matières en suspension et paramètres optiques (turbidimétrie).Une étude des différentes méthodes de mesure de la masse volumique appliquées aux eaux résiduaires a été effectuée par G. Chebbo (1992). Il en a conclu que le pycnomètre à gaz type Beckman est le seul appareil donnant satisfactio...

  18. Mesures de spectrométrie et de dosimétrie neutron aux postes de travail pour l'étalonnage de dosimètres individuels PGP-DIN

    OpenAIRE

    Itié, C.; Muller, H.; Asselineau, B.; Médioni, R.; Crovisier, P.; Valier-Bradier, P.; Groetz, J. E.; Piot, J.

    2002-01-01

    International audience; (ManuAcrit r e p le 3 juillet 2002, accepté le 29 septembre 2002) Dans le cadre de la mise en application des recommandations décrites dans la publication 60 de la CIPR, des mesures de spectrométrie neutron ont été réalisées à plusieurs postes de travail au CEA de Valduc. Le but de ces mesures était la détermination de nouveaux coefficients d'étalonnage h affecter aux dosimètres individuels neutron PGP-DIN afin de restituer correctement les doses reçues par les opérate...

  19. Neutron noise in nuclear reactors; Le bruit neutronique des reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Blaquiere, A. [Institut National des Sciences et Techniques Nucleaires (France); Pachowska, R. [Universite Technique de Varsovie (Poland)

    1961-06-15

    The power of a nuclear reactor, in the operating conditions, presents fluctuations due to various causes. This random behaviour can be included in the study of 'noises'. Among other sources of noise, we analyse hereafter the fluctuations due: a) to the discontinuous emissions of neutrons from an independent source; b) to the multiplication of neutrons inside the reactor. The method which we present makes use of the analogies between the rules governing a nuclear reactor in operation and a number of radio-electrical systems, in particular the feed-back loops. The reactor can be characterized by its 'passing band' and is described as a system submitted to a sequence of random pulses. In non linear operating condition, the effect of neutron noise is defined by means of a non-linear functional, this theory is thus related to previous works the references of which are given at the end of the present report. This leads us in particular in the case of nuclear reactors to some results given by A. Blaquiere in the case of radio-electrical loops. (author) [French] La puissance d'un reacteur nucleaire, dans les conditions du regime, est affectee de fluctuations dont les causes sont tres diverses. Ce comportement aleatoire rentre dans le cadre general de l'etude des 'bruits'. Entre autres sources ce bruit, nous analysons ici les fluctuations dues: a) a l'emission discontinue des neutrons provenant d'une source autonome; b) a la multiplication des neutrons au sein du reacteur. La methode que nous introduisons exploite les analogies entre les lois qui regissent un reacteur nucleaire au regime et certains systemes radioelectriques, en particulier les circuits a boucle de reaction. Le reacteur est caracterise par sa 'bande passante' et est decrit comme un systeme soumis a une succession d'impulsions aleatoires. Dans les conditions de fonctionnement non lineaires, l'effet du bruit neutronique est precise en utilisant une fonctionnelle non lineaire, ce qui relie cette theorie a

  20. Statistical Control of Measurement Quality; Controle Statistique de la Qualite de la Mesure; Statisticheskim kontrol' kachestva izmerenij; Control Estadistico de la Calidad de las Mediciones

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, C. A. [Battelle Memorial Institute, Richland, WA (United States)

    1966-02-15

    Effective nuclear materials management, and hence design and operation of associated material control systems, depend heavily on the quality of the quantitative data on which they are based. Information concerning the reliability of the measurement methods employed is essential to both the determination of data requirements and the evaluation of results obtained. Any method of analysis should be (1) relatively free from bias and (2) reproducible, or, in more usual terminology, precise. Many statistical techniques are available to evaluate and control the reproducibility of analytical results. Economical and effective experimental designs have been developed for the segregation of different sources of measurement error. Procedures have been developed or adapted tot use in maintaining and controlling the precision of routine measurements. All of these techniques require that at least some measurements must be duplicated, but duplication of all measurements can be justified only when the detection of every gross error, or mistake, is extremely important. Three types of measurement bias can be considered: (1) bias relative to a standard, (2) bias relative to prior experience, and (3) bias relative to a group. The first refers to the degree to which the measurements obtained deviate systematically from some ''standard'' which is unbiased either (1) by definition, or (2) because all known sources of bias have been removed. The second in concerned with the presence of systematic differences over a period of time. The third type of bias concerns the relationship between different physical entities or individuals at a given time. Recent developments in statistical methodology applicable to the evaluation of all three types of bias are discussed. Examples of the use of the statistical techniques discussed on Hanford data are presented. (author) [French] La gestion efficace des matieres nucleaires et, par consequent, la conception et le fonctionnement des systemes de controle

  1. A mathematical model for cost of maritime transport. Application to competitiveness of nuclear vessels; Modele mathematique du cout de transport maritime application a la competitivite du navire nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Dorval, C [Commissariat a l' Energie Atomique, 75 - Paris (France)

    1966-05-01

    competitivite, nous considerons deux cas: 1) le tonnage a transporter annuellement est limite; 2) le tonnage a transporter annuellement n'est pas limite. Dans les deux cas, nous recherchons les optima du navire classique et du navire nucleaire, et nous les comparons. Nous construisons les courbes de competitivite en fonction des rapports des couts de combustible nucleaire et classique, et des couts marginaux de la puissance nucleaire et classique. Ces courbes traduisent les valeurs limites des deux rapports ci-dessus pour lesquelles les couts de transport du navire nucleaire et du navire classique sont egaux. Suivant les hypotheses adoptees pour le marche du fret et pour la limite du tonnage transporte annuellement, nous avons des courbes de competitivite tres differentes. De toute facon, c'est l'augmentation de puissance qui favorise le nucleaire. On peut obtenir cette augmentation en accroissant le deplacement ce qui est toujours interessant dans la mesure ou le fret le justifie, et en accroissant la vitesse, mais dans ce cas le modele met en evidence l'existence d'une limite. Le sous-marin peut presenter certains avantages (moindre resistance hydrodynamique de l'eau, possibilite de vitesse plus reguliere, et eventuellement reduction de trajet) qui rendent la competitivite du nucleaire plus aisee. (auteur)

  2. Determination of the mean free path of the thermal neutrons transport by the measure of a complex diffusion length; Determination du libre parcours moyen de transport des neutrons thermiques par la mesure d'une longueur de diffusion complexe

    Energy Technology Data Exchange (ETDEWEB)

    Raievski, V; Horowitz, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The further method is the outcome of a technique used in the study of neutrons in scattering and slowing-down environment. In this technique, we replace the constant sources used in the classic experiences by modulated sources with a variable frequency. The object of this article is to describe the extension of the method for the mean free path for transport of thermal neutrons and also to indicate the possible applications for other sizes, as the slowing length, or the absolute value of the cross-section of the boron. (M.B.) [French] La methode qui va etre decrite est l'aboutissement d'une technique utilisee dans l'etude des milieux ou diffusent et se ralentissent des neutrons. Dans cette technique, on remplace les sources constantes utilisees dans les experiences classiques par des sources modulees, a frequence variable. L'objet de cet article est de decrire l'extension de la methode a la mesure du libre parcours moyen de transport des neutrons thermiques et egalement d'indiquer les applications possibles a la mesure d'autres grandeurs, telles que la longueur de ralentissement, ou la valeur absolue de la section de capture du bore. (M.B.)

  3. Examples of analysis by activation; Exemples d'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    We were used various nuclear reactions to do some analysis by neutron or by X-ray activation. We used the french reactor core Zoe as neutrons sources and an Allis-Chalmers betatron as X-rays sources for the dosage of the light elements. The described processes were revealed fast and particularly useful for determination of traces. The fact that most of them don't require any chemical operations, is especially substantial when the solubilization of the sample is difficult. (M.B.) [French] Nous avons utilise des reactions nucleaires diverses pour effectuer des analyses par activation neutronique ou par rayon X. Nous avons utilise la pile francaise Zoe comme sources de neutrons et un betatron Allis-Chalmers comme sources de rayons X pour le dosage des elements legers. Les procedes decrits se sont reveles rapides et particulierement utiles dans la determination des traces. Le fait que, pour la plupart, ils n'exigent pas d'operations chimiques, est particulierement appreciable lorsque la solubilisation des echantillons est difficile. (M.B.)

  4. Amorphous silicon cells for the measurement of photosynthetically active radiation; Utilisation des cellules au silicium amorphe pour la mesure du rayonnement photosynthétiquement actif (400-700 nm)

    Energy Technology Data Exchange (ETDEWEB)

    Chartier, M. [Institut National de la Recherche Agronomique, Thiverval-Grignon (France); Bonchretien, P.; Allirand, J. M.; Gosse, G.

    1989-07-01

    Numerical simulation and experimental measurements from amorphous silicon cells in comparison with these now used in ecophysiology illustrate the interest of amorphous silicon cells for the measurement of PAR incident, reflected, and transmitted below the canopy [French] La simulation et la confrontation expérimentale ces réponses des cellules au silicium amorphe par rapport à celles des capteurs existants montrent l’intérêt des cellules au silicium amorphe pour la mesure du rayonnement PAR (exprimé en densité de flux de photons) incident, réfléchi et transmis sous un couvert végétal.

  5. Use of an oscillation technique to measure effective cross-sections of fissionable samples in critical assemblies; Mesure des sections efficaces effectives d'echantillons fissiles par une methode d'oscillation dans les-assemblages critiques

    Energy Technology Data Exchange (ETDEWEB)

    Tretiakoff, O; Vidal, R; Carre, J C; Robin, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The authors describe the technique used to measure the effective absorption and neutron-yield cross-sections of a fissionable sample. These two values are determined by analysing the signals due to the variation in reactivity (over-all signal) and the local perturbation in the flux (local signal) produced by the oscillating sample. These signals are standardized by means of a set of samples containing quantities of fissionable material ({sup 235}U) and an absorber, boron, which are well known. The measurements are made for different neutron spectra characterized by lattice parameters which constitute the central zone within which the sample moves. This technique is used to study the effective cross-sections of uranium-plutonium alloys for different heavy-water and graphite lattices in the MINERVE and MARIUS critical assemblies. The same experiments are carried out on fuel samples of different irradiations in order to determine the evolution of effective cross-sections as a function of the spectrum and the irradiations. (authors) [French] On decrit la methode utilisee pour mesurer les sections efficaces effectives d'absorption et de production de neutrons d'un echantillon fissile. Ces deux grandeurs sont determinees en analysant les signaux dus a la variation de reactivite (signal global) et a la perturbation locale de flux (signal local) produits par l'echantillon oscillant. Ces signaux sont etalonnes a l'aide d'un jeu d'echantillons dont les teneurs en materiau fissile ({sup 235}U) et en absorbeur (bore) sont bien connues. Les mesures sont realisees pour differents spectres de neutrons caracterises par les parametres du reseau constituant la zone centrale a l'interieur de laquelle se deplace l'echantillon. A l'aide de cette methode on etudie les sections efficaces effectives d'alliage uranium-plutonium pour differents reseaux a eau lourde et a graphite dans les assemblages crtiques MINERVE et MARIUS. Les memes experiences sont effectuees sur des echantillons de

  6. Calibration of langmuir probes by a microwave method; Etalonnage des sondes de langmuir par une methode hyperfrequence

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Measurements of the electronic density of a plasma between 10{sup 6} and 10{sup 8} e/cm{sup 3}, made by the Langmuir probe and by resonance frequency shift of a cavity are compared. (author) [French] On compare les mesures de la densite electronique d'un plasma peu dense 10{sup 6} < ne < 10{sup 8} e/cm{sup 3}, par sonde de Langmuir et par glissement de la frequence de resonance d'une cavite contenant le plasma. (auteur)

  7. Purification by high vacuum fusion and progressive solidification of uranium from electrolytic origin; Purification par fusion sous vide eleve et solidification progressive d'uranium d'origine electrolytique

    Energy Technology Data Exchange (ETDEWEB)

    Poeydomenge, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-01-15

    grain observed, so-called secondary recrystallisation. in appendix, the method for measuring the electrical resistance by induction (with direct current)is studied from the fundamental and experimental point of view. The author applied it to the particular case of uranium for measuring the low-temperature resistance of the bars from the same which solidified first to the least pure ended the ingot. (author) [French] Dans le cadre de recherches generales sur la purification de l'uranium par fusion de zone, on a entrepris de determiner le degre de purification que l'on pourrait atteindre par une simple solidification progressive a vitesse et direction soigneusement controlees d'un uranium de purete nucleaire courante. Cet uranium de purete intermediaire fournirait un materiau de depart approprie au mode de purification ultime qu'est la fusion a zone verticale, dite ''flottante''. Dans ce but, des lingots d'uranium d'origine electrolytique ont ete refondus sous vide (2 a 5 x 10{sup -6} mm) dans une longue nacelle en UO{sub 2} apres une monte lente en temperature pour eliminer le maximum de gaz et d'impuretes volatiles. Ce degazage et cette volatilisation d'impuretes sont completes par maintien prolonge a haute temperature du bais liquide. Celui-ci est ensuite solidifie d'une extremite a l'autre de la nacelle par deplacement a vitesse lente et constante du front de solidification de facon a obtenir une repartition des impuretes selon les lois etablies par PFANN. Differentes methodes experimentales ont permis de montrer que le metal solidifie en premier lieu est nettement plus pur que celui de la partie solidifie a l'extremite opposee du lingot. Le degre de purification du metal en tete du lingot a ete apprecie, soit quantitativement par mesure du rapport des resistivites electriques a la temperature ambiante et a celle de l'azote liquide, soit qualitativement par l'examen de la structure micrographique et par l'etude de la recristallisation du metal. D'une part, le metal

  8. Thermal neutron flux measurements using neutron-electron converters; Mesure de flux de neutrons thermiques avec des convertisseurs neutrons electrons

    Energy Technology Data Exchange (ETDEWEB)

    Le Meur, R; Lecomte, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The operation of neutron-electron converters designed for measuring thermal neutron fluxes is examined. The principle is to produce short lived isotopes emitting beta particles, by activation, and to measure their activity not by extracting them from the reactor, but directly in the reactor using the emitted electrons to deflect the needle of a galvanometer placed outside the flux. After a theoretical study, the results of the measurements are presented; particular attention is paid to a new type of converter characterized by a layer structure. The converters are very useful for obtaining flux distributions with more than 10{sup 7} neutrons cm{sup -2}*sec{sup -1}. They work satisfactorily in pressurized carbon dioxide at 400 Celsius degrees. Some points still have to be cleared up however concerning interfering currents in the detectors and the behaviour of the dielectrics under irradiation. (authors) [French] On examine le fonctionnement de convertisseurs neutrons electrons destines a des mesures de flux de neutrons thermiques. Le principe est de former par activation des isotopes a periodes courtes et a emission beta et de mesurer leur activite non pas en les sortant du reacteur, mais directement en pile, utilisant les electrons emis pour faire devier l'aiguille d'un galvanometre place hors flux. Apres une etude theorique, on indique des resultats de mesures obtenus, en insistant particulierement sur un nouveau type de convertisseur, caracterise par sa structure stratifiee. Les convertisseurs sont tres interessants pour tracer, des cartes de flux a partir de 10{sup 7} neutrons cm{sup -2}*s{sup -1}. Ils sont utilisables pour des flux de 10{sup 14} neutrons cm{sup -2}*s{sup -1}. Ils fonctionnent correctement dans du gaz carbonique sous pression a 400 C. Des points restent cependant a eclaircir concernant les courants parasites dans les detecteurs et le comportement des dielectriques pendant leur irradiation. (auteur)

  9. Mesure asymétrie avant-arriere des quarks lourds a LEP1 avec le détecteur OPAL

    CERN Document Server

    Lafoux, H

    A partir de l'ensemble des données accumulées par OPAL au cours de la première phase de fonctionnement du LEP, nous avons mesuré l'asymétrie avant-arrière des quarks b et c au voisinage du pic du Zo. Utilisant une méthode traditionnelle, basée sur la détection des leptons produits dans les désintégrations semi-leptoniques des hadrons lourds, nous avons cherché à optimiser chaque étape de la mesure, en mettant en œuvre les algorithmes les plus appropriés. Le recours aux réseaux de neurones artificiels s'est en particulier avéré d'une grande utilité lorsque le problème à résoudre impliquait la prise en compte simultanée de multiples sources d'informations, d'origine et de nature très variées. Nos résultats sont en bon accord avec ceux des autres mesures effectuées à LEP et compatibles avec les prédictions du Modèle Standard pour un quark top de 174 ± 31 GeV/c2 et un boson de Higgs de masse comprise entre 60 et 1000 GeV/c2

  10. Balance between automation and human actions in nuclear power plant operation. Results of international cooperation; Equilibre entre automatisation et action humaine dans la conduite des centrale nucleaires, resultats de la cooperation internationale

    Energy Technology Data Exchange (ETDEWEB)

    Sun, B [CEA Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. d' Analyse de Surete; Bastl, W [Gesellschaft fuer Reaktorsicherheit m.b.H. (GRS), Garching (Germany); Olmstead, R [Atomic Energy of Canada Ltd, Mississauga (Canada); Oudiz, A [Electric Power Research Inst., Palo Alto, CA (United States); Jenkinson, J [Nuclear Electric PLC, Gloucester (United Kingdom); Kossilov, A [International Atomic Energy Agency, Vienna (Austria)

    1990-07-01

    'est portee sur le concept de reacteurs 'intrinsequement surs', ce qui pourrait simplifier les equipements de securite, et reduire la complexite des systemes d'information et de controle. La repartition des taches entre homme et machine pourrait bien etre l'une des etapes les plus critiques dans la conception d'une centrale nucleaire et l'un des progres les plus sensibles; de ce fait, elle garantit une approche dans la conception qui est commensurable en qualite avec les hauts niveaux de securite et de qualite de production recherches pour les centrales nucleaires. C'est dans ce climat que l'Agence Internationale pour l'Energie Atomique (AIEA) a constitue en 1989 un groupe de recherche auquel participent les pays membres, lequel groupe possede une experience etendue dans le domaine de l'automatisation des centrales nucleaires. La tache de ce groupe etait d'evaluer ou se situait le juste equilibre entre actions manuelles et automatiques dans la conduite des centrales. Se basant sur des recherches anterieures et sur l'experience de ses membres, le groupe a determine que toute solution unique, totalement deterministe, au probleme de la repartition des taches est impossible. Cependant, dans la mesure ou le role de l'operateur est appele progressivement a se transformer, avec le temps, en un role de gestionnaire du systeme, il est imperatif qu'une procedure systematique de repartition des taches soit utilisee par l'equipe chargee de la conception. Le groupe a propose une methodologie qui s'appuie sur des travaux deja publies, mais il adopte une approche pragmatique, adaptee aux besoins reels des projets. Cette methodologie caracterise un certain nombre de facteurs qui relevent des processus de prise de decision, guide une telle prise de decision, et identifie les secteurs dont il considere qu'ils doivent devenir l'objet de recherches ulterieures. (author)

  11. Possibilities and limitations of analogue methods for studying the dynamics of nuclear power stations; Possibilites et limitations du calcul analogique pour les etudes dynamiques de centrales nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Caillet, C; Deat, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    1. Introduction: the present paper is devoted to analog simulation of problems related to nuclear reactors other than the simulation of the kinetic equations which is well known. 2. Thermodynamic problems: various problems relative to temperature evolution in a reactor, in a pipe, in an exchanger, in a turbine, are studied, and simulation techniques used by earlier authors are critically reviewed. 3. Pipe simulators: it is shown that this problem can be solved by the use of specialized simulators which will be described and analysed. 4. Rotating machine simulators: the particular aspect of rotating machine calculations introducing frequent use of diagrams is emphasized. A simulator requiring both digital and analogue methods is described. 5. The study of a nuclear power station: as an example it is proposed to discuss problems a rising in connection with the preceding elements (a, b, c, d) when simulating the behaviour of large nuclear plants. The part played by ordinary computing elements for the simulation of the different servomechanism transfer functions is considered and process of regulation is outlined. 6. Conclusion: the necessity of the use of high quality simulators and computers is underlined and the accuracy of the solutions is discussed. (author)Fren. [French] 1. Cinetique des reacteurs: la simulation des equations cinetiques d'un reacteur nucleaire ne pose desormais plus de probleme. II est donc possible de faire le point des differentes applications de la technique analogique dans ce domaine. 2. Les problemes thermodynamiques: on discute les differents problemes poses par l'evolution des temperatures dans un reacteur, dans une tuyauterie, dans un echangeur, dans une turbine, et on passe en revue les techniques de simulation proposees jusqu'a ce jour. 3s simulateurs de tuyauteries: on montre comment les differents problemes poses ci-dessus peuvent etre resolus, pour une classe tres vaste de reacteurs par l'emploi de simulateurs speciaux que l

  12. A new detector for the measurement of neutron flux in nuclear reactors; Nouvelle methode de mesure des flux de neutrons dans les reacteurs atomiques

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L; Labeyrie, J; Tarassenko, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The detector described is designed for the instantaneous measurement of thermal neutron fluxes, in the presence of high {gamma} ray activity; this detector can withstand temperatures as high as 500 deg. C. It is based on the following principle: radioactive atoms resulting from heavy-nucleus fission are carried by a gas flow to a detector recording their {beta} and {gamma} disintegration. Thermal neutron fluxes as low as few neutrons per cm{sup 2} per second can be measured. This detector may be used to control a nuclear reactor, to plot the thermal flux distribution with an excellent definition (1 mm{sup 2}) for fluxes higher than 10{sup 8} n/cm{sup 2}/s. The time response of the system to a sharp variation of flux is limited, in case of large fluxes, to the transit time of the gas flow between the fission product emitter and the detector; of the order of one tenth of a sec per meter of piping. The detector may also be applied for spectroscopy of fission products eider than 0,1 s. (author)Fren. [French] On decrit un appareil permettant la mesure instantanee des flux de neutrons thermiques accompagnes de flux intenses de rayons {gamma} et situes dans des enceintes pouvant etre portees a des temperatures superieures a 500 deg. C. On utilise la radioactivite des atomes resultant de la fission des noyaux lourds; ces atomes sont entraines par un courant gazeux vers un detecteur de radioactivite qui enregistre leurs desintegrations {beta} et {gamma}. On peut mesurer des flux partir de quelques neutrons thermiques par cm{sup 2} et par seconde. L'appareil permet de suivre la puissance d'un reacteur atomique, de tracer des cartes de densite de neutrons avec une tres bonne definition (1 mm{sup 2}) dans le cas de flux superieurs a 10{sup 8} cm{sup 2}/s. Le temps de reponse du systeme a une variation du flux de neutrons est limite, poes flux importants, par le temps de transit du gaz entre l'emetteur de produits de fission et le detecteur: soit quelques dizaines de

  13. Lidiam - direct-link computer for the photo measurement apparatus of a bubble chamber; Lidiam - liaison directe d'une calculatrice aux appareils de mesure de photos de chambre a bulles

    Energy Technology Data Exchange (ETDEWEB)

    Deler, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The treatment of bubble chamber pictures can be considerably improved by connecting conventional measuring machines to a small computer providing continuous control of the later as well as the immediate detection of errors and their immediate corrections. The computer will also perform first processing of the measured data. In addition the system described will improve the effective yield of each apparatus and facilitates the control of the data. A description is given here of the apparatus and of some future extensions. (author) [French] L'exploitation des cliches de chambre a bulles peut etre sensiblement amelioree par la jonction directe des appareils de mesure a une calculatrice qui permettra la detection immediate des erreurs et leurs corrections, le controle continu des appareils et un premier traitement des evenements mesures. De plus, le rendement effectif des appareils de mesure sera notablement augmente et la gestion ainsi que l'exploitation des mesures grandement facilitees. Nous presentons ici la description d'un dispositif de ce genre ainsi que les projets d'extensions envisagees.

  14. Nuclear Materials Management and its Relationship to Nuclear Safety and Criticality Control; La Gestion des Matieres Nucleaires et ses Rapports avec la Securite Nucleaire et le Controle de la Criticite; Obrashchenie s yadernymi materialami i ego svyaz' s yadernoj bezopasnost'yu i kontrolem nad kritichnost'yu; La Administracion de Materiales Nucleares y sus Relaciones con la Seguridad Nuclear y el Control de la Criticidad

    Energy Technology Data Exchange (ETDEWEB)

    Tingey, F. H. [Phillips Petroleum Company, Idaho Falls, ID (United States)

    1966-02-15

    ; elles dependent donc de ce service pour les renseignements precis dont elles ont besoin pour assumer leurs responsabilites. C'est en premier lieu a la personne chargee de la surveillance generale du circuit qu'il incombe de veiller a ce qu'en aucun point les matieres nucleaires ne puissent, par inadvertance, atteindre l'etat critique. Pour mettre au point des mesures preventives, il faut tenir compte d'au moins trois categories de problemes, a savoir: a) Les problemes scientifiques et techniques lies a l'evaluation des risques que presente une certaine quantite de matieres fissiles disposee selon une certaine geometrie dans un certain endroit; b) Les problemes materiels souleves par les restrictions qu'imposent les considerations scientifiques ou techniques; c) Les problemes purement administratifs a resoudre pour respecter les restrictions et les conditions particulieres imposees par les considerations techniques et materielles. Pour aider le responsable de la surveillance a s'acquitter de sa tache, certaines organisations prevoient des groupes ou des comites specialises dans des domaines particuliers. Les problemes techniques sont le plus souvent soumis a des specialistes de la criticite, generalement constitues en comites de securite nucleaire, qui connaissent bien les donnees experimentales des systemes critiques et peuvent, par le calcul, exploiter cette experience pour resoudre les problemes qui se posent. En ce qui concerne les problemes materiels, ils sont soumis a des groupes de techniciens que l'on met au courant des conditions particulieres qu'imposent les facteurs techniques et qui connaissent bien les limites de fonctionnement de l'installation. Quant aux problemes administratifs, le responsable de la surveillance se charge de les resoudre' en reglementant les activites en consequence. Le service de gestion des matieres nucleaires peut apporter une aide precieuse au responsable de la surveillance. C'est tout d'abord a ce service qu'il incombe d'alerter le

  15. Etude du mecanisme de predissociation de l'ion moleculaire de protoxyde d'azote par la mesure de l'energie cinetique des fragments de l'oxyde nitrique et de l'oxygene

    Science.gov (United States)

    Delisle, Claude

    La reaction N2 + O+ ↔ NO + + N, laquelle joue un role important dans la physique de la haute atmosphere, a ete le sujet de plusieurs etudes. Bien que cette reaction ait ete l'objet d'une quantite importante de travaux, ces derniers ne permettent toutefois pas de comprendre entierement le mecanisme d'un point de vue quantique, particulierement les niveaux d'energie excites des fragments qui permettent cette reaction. Puisque cette reaction n'est pas tres facile a reproduire en laboratoire, nous avons utilise la spectroscopie laser sur faisceaux d'ions rapides afin d'explorer les limites de dissociation de l'ion moleculaire intermediaire de cette reaction, a savoir l'ion N2O+. Le faisceau d'ions N2O+ rapides, apres excitation de l'ion moleculaire vers un niveau predissocie de l'etat A2Sigma+, se dissocie pour produire les fragments ioniques O+ et NO+. Par la mesure de la variation du nombre de fragments ioniques en fonction de l'energie cinetique des ions N2O+, nous avons enregistre les spectres de predissociation de l'ion N2O+. Lorsque c'etait possible, nous avons procede a l'analyse de ces spectres de dissociation afin d'en tirer les constantes moleculaires. Pour certaines des transitions rotationnelles intenses, nous avons mesure l'energie cinetique acquise par les fragments lors de la predissociation de l'ion N 2O+. Afin d'analyser les distributions en energie cinetique, nous avons developpe une simulation de l'experience en considerant, entre autres choses, la position des niveaux de vibration et de rotation des fragments diatomiques de chacune des limites de dissociation de N2O+. Les resultats de l'analyse sont exprimes en termes de population des niveaux de vibration des fragments diatomiques pour une distribution donnee de la population des niveaux de rotation des fragments. Les resultats ainsi obtenus, montrent que les fragments diatomiques sont produits dans des niveaux de vibration fortement excites. De tels niveaux d'excitation ne correspondent pas aux

  16. The dangers of irradiate uranium in nuclear reactors; Les dangers de l'uranium irradie dans les reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Jammet, H; Joffre, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The danger of the uranium cans sur-activated by the use in the nuclear reactors is triple: - Irradiation from afar, during manipulations of the cans. - Contamination of air when decladding. - Contamination of air by fire of uranium in a reactor in function The first two dangers are usual and can be treated thanks to the rules of security in use in the atomic industry. The third has an accidental character and claimed for the use of special and exceptional rules, overflowing the industrial setting, to reach the surrounding populations. (authors) [French] Le danger des cartouches d'uranium suractive par utilisation dans les reacteurs nucleaires est triple: - Irradiation a distance, lors des manipulations des cartouches. - Contamination de l'air au moment de leur degainage. - Contamination de l'air par incendie d'uranium dans un reacteur en fonctionnement. Les deux premiers dangers sont habituels et peuvent etre traites grace aux regles de securite en usage dans l'industrie atomique. Le troisieme revet un caractere accidentel et reclame l'emploi de regles speciales et exceptionnelles, debordant le cadre industriel, pour atteindre celui des populations environnantes. (auteurs)

  17. The activity of {gamma}-emitters as measured by ionisation chambers the determination of the specific emission coefficient {gamma} for some radio-elements (1961); Mesure de l'activite des emetteurs {gamma} par chambre d'ionisation. Determination du coefficient specifique d'emission {gamma} de quelques radioelements (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The object of this work is to study techniques of measurement using the gamma ionisation chamber, making it possible either to measure the activities of radioactive sources, or to determine the specific emission coefficient {gamma} (or the coefficient K) of a given radioelement. The ionisation chambers studied belong to two categories: graphites cavity-chambers, and 4 {pi} {gamma} chambers. For the cavity-chamber measurements, the different correction factors of which account must be taken have been calculated, in particular the geometric and hygrometric corrections. The absorption and auto-absorption corrections have led to the introduction of the notion of the 'effective energy {gamma}' of a radioelement. In the case of 4 {pi} {gamma} chambers, it has been shown that appropriately shaped electrodes make it possible to improve their performances. One of the chambers described permits the measurement of {beta} emitters using the associated Bremsstrahlung. In order to measure the K coefficient of some radioelements, it has been found useful a 4 {pi} {gamma} chamber with graphite walls, the measurement being carried out by comparison with a radium standard. The validity of the method was checked with radioelements for whom the K coefficient values are well-known ({sup 24}Na, {sup 60}Co, {sup 131}I, {sup 198}Au). For other radioelements, the following values were obtained (expressed in r cm{sup 3} mc{sup -1} h{sup -1}): {sup 51}Cr: 0,18; {sup 56}Mn: 8,8; {sup 65}Zn: 3,05; {sup 124}Sb: 9,9; {sup 134}Cs: 9,3; {sup 137}Cs: 3,35; {sup 141}Ce: 0,46; {sup 170}Tm: 0,023; {sup 192}Ir: 24,9; {sup 203}Hg: 1,18; These values have been corrected for the contribution to the dose of the fluorescent radiation which may be emitted by the source, except in the case of Tm{sup 170}. In the last part of this work, the performances of the different electro-metric devices used were compared. (author) [French] Le but de ce travail est d'etudier les techniques de mesure par chambre d

  18. Évaluation du niveau de pollution par les métaux lourds des lacs ...

    African Journals Online (AJOL)

    La présente étude a pour objectif principal d'évaluer le niveau de pollution métallique des lacs Bini et Dang (Ngaoundéré, Cameroun) à travers l'analyse des eaux et des sédiments de surface. La concentration des métaux lourds (Ni, Cr, Fe, Pb, Cd, Zn) a été mesurée par spectrophotométrie d'absorption atomique.

  19. Use of particles other than neutrons in activation analysis; Emploi de particules autres que les neutrons en analyse par actuation

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-15

    Nuclear reactions obtained by irradiation in {gamma} Bremsstrahlung, {alpha} particles and protons are particularly suitable for dosing very small traces of light elements. We consider the possibilities presented by activation in {gamma} radiation of 28 MeV maximum energy, mainly for the measurement of C, F, N, O, P and S. Non-destructive methods of analysis for beryllium are described. Under certain conditions they may also be used for other elements such as B, Ca, Li and Na. We give also the results of our first experiments carried out in an attempt to find a method for dosing carbon and oxygen by irradiation in {alpha} particles and protons. For each type of activation the possible types of interference with other nuclear refections are considered. (author) [French] Des reactions nucleaires obtenues par irradiation dans des rayons {gamma} de freinage, des particules {alpha} et des protons, sont particulierement indiquees pour les dosages de traces ultimes de certains elements legers. Nous etudions les possibilites offertes par les activations en rayons {alpha} d'energie maximum 28 MeV, principalement pour les dosages de C, F, N, O, P et S. Des methodes d'analyse non destructives appliquees au beryllium sont decrites. Sous certaines conditions, elles peuvent egalement etre utilisees pour d'autres materiaux comme B, Ca, Li et Na. Nous donnons d'autre part les resultats de nos premieres experiences effectuees pour la mise au point des methodes de dosage du carbone et de l'oxygene par irradiation dans les particules {alpha} et les protons. Pour chaque type d'activation, les possibilites d'interferences avec d'autres reactions nucleaires sont examinees. (auteur)

  20. La mesure du danger

    CERN Document Server

    Manceron, Vanessa; Revet, Sandrine

    2014-01-01

    La mesure du danger permet d’explorer des dangers de nature aussi diverse que la délinquance, la pollution, l’écueil maritime, la maladie ou l’attaque sorcellaire, l’extinction d’espèces animales ou végétales, voire de la Planète tout entière. Au croisement de la sociologie, de l’anthropologie et de l’histoire, les différents articles analysent les pratiques concrètes de mesure pour tenter de comprendre ce qui se produit au cours de l’opération d’évaluation du danger sans préjuger de la nature de celui-ci. L’anthropologie a contribué à la réflexion sur l’infortune en s’intéressant aux temporalités de l’après : maladies, catastrophes, pandémies, etc. et en cherchant à rendre compte de l’expérience des victimes, de leur vie ordinaire bouleversée, de la recomposition du quotidien. Elle s’intéresse aussi aux autres types de mesures, les savoirs incorporés, qui reposent sur l’odorat, la vue ou le toucher et ceux qui ressortent d’une épistémologie « non ...

  1. Concentration urinaire de bisphénol A et obésité chez les adultes : résultats de l’Enquête canadienne sur les mesures de la santé

    Directory of Open Access Journals (Sweden)

    Minh T. Do

    2017-01-01

    Full Text Available Introduction : Des études chez l’animal ont révélé que l’exposition au bisphénol A (BPA affecte le métabolisme des lipides et favorise la prise de poids. Des études épidémiologiques récentes appuient aussi l’existence d’un lien entre le BPA et l’obésité chez l’humain, mais la plupart d’entre elles se limitent à une seule mesure de l’adiposité ou ne tiennent pas compte des facteurs de confusion alimentaires possibles. Cette étude vise à examiner les associations entre les concentrations urinaires de BPA et les mesures de l’adiposité dans un échantillon national représentatif des adultes canadiens. Méthodologie : Nous avons réalisé des analyses à l’aide de données de biosurveillance et de données anthropométriques mesurées directement auprès de 4 733 adultes de 18 à 79 ans dans le cadre de l’Enquête canadienne sur les mesures de la santé (2007-2011. Nous avons utilisé des modèles de régression logistique multinomiale et binaire pour estimer les associations entre, d’une part, les concentrations urinaires de BPA et, d’autre part, les diverses catégories d’indice de masse corporelle (IMC (embonpoint par opposition à poids insuffisant ou normal; obésité par opposition à poids insuffisant ou normal et un tour de taille élevé (102 cm ou plus pour les hommes; 88 cm ou plus pour les femmes en tenant compte des facteurs de confusion possibles. Des analyses de régression linéaire ont aussi été effectuées pour évaluer les associations entre les concentrations urinaires de BPA et des mesures de l’IMC et du tour de taille. Résultats : On a pu associer positivement la concentration urinaire de BPA et l’obésité (définie par l’IMC. Le rapport de cotes s’est situé à 1,54 (intervalle de confiance [IC] à 95 % : 1,002 à 2,37 dans le quartile de BPA le plus élevé par rapport au plus bas (test de tendance, p = 0,041. La concentration urinaire de BPA n’a pas été associ

  2. The design and construction of a nuclear free-precession magnetometer; Etude et realisation d'un magnetometre a precession libre nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Baconnier, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-10-15

    After presenting the advantages of nuclear magnetic resonance with respect to electromagnetic processes, as far as the measurement of the earths' magnetic field is concerned, we deal with the macroscopic theory for the Bloch model and analyse Packard and Varions' experiment. The development of a particular absolute free-precession magnetometer is studied, and the conditions are determined for obtaining a maximum amplitude signal as a function of the geometrical form of the detector coil, of the method of cut-off, and of the coupling between various parts of the system. After having described in detail the technology of amplifiers, we consider the problem of the measurement of the frequency of precession for which an original solution, of analogy form, is proposed and discussed. Complete plans of the equipment are given in an appendix. (author) [French] Apres avoir presente les avantages de la resonance magnetique nucleaire relativement aux procedes electromagnetiques, en ce qui concerne la mesure du champ magnetique terrestre, on traite de la theorie macroscopique dans le modele de Bloch et analyse l'experience de Packard et Varian. On etudie une realisation particuliere d'un magnetometre absolu a precession libre et determine les conditions d'obtention d'un signal d'amplitude maximale en fonction de la forme geometrique du bobinage detecteur, de la methode de coupure, et du couplage entre les differents elements du montage. Apres avoir decrit en detail la technologie des amplificateurs, on aborde le probleme de la mesure de la frequence de precession, pour laquelle une solution originale, sous forme analogique, est proposee et discutee. En annexe est joint un dossier complet des plans de la realisation. (auteur)

  3. La pelade par plaques

    Science.gov (United States)

    Spano, Frank; Donovan, Jeff C.

    2015-01-01

    Résumé Objectif Présenter aux médecins de famille des renseignements de base pour faire comprendre l’épidémiologie, la pathogenèse, l’histologie et l’approche clinique au diagnostic de la pelade par plaques. Sources des données Une recension a été effectuée dans PubMed pour trouver des articles pertinents concernant la pathogenèse, le diagnostic et le pronostic de la pelade par plaques. Message principal La pelade par plaques est une forme de perte pileuse auto-immune dont la prévalence durant une vie est d’environ 2 %. Des antécédents personnels ou familiaux de troubles auto-immuns concomitants, comme le vitiligo ou une maladie de la thyroïde, peuvent être observés dans un petit sous-groupe de patients. Le diagnostic peut souvent être posé de manière clinique en se fondant sur la perte de cheveux non cicatricielle et circulaire caractéristique, accompagnée de cheveux en « point d’exclamation » en périphérie chez ceux dont le problème en est aux premiers stades. Le diagnostic des cas plus complexes ou des présentations inhabituelles peut être facilité par une biopsie et un examen histologique. Le pronostic varie largement et de mauvais résultats sont associés à une apparition à un âge précoce, une perte importante, la variante ophiasis, des changements aux ongles, des antécédents familiaux ou des troubles auto-immuns concomitants. Conclusion La pelade par plaques est une forme auto-immune de perte de cheveux périodiquement observée en soins primaires. Les médecins de famille sont bien placés pour identifier la pelade par plaques, déterminer la gravité de la maladie et poser le diagnostic différentiel approprié. De plus, ils sont en mesure de renseigner leurs patients à propos de l’évolution clinique de la maladie ainsi que du pronostic général selon le sous-type de patients.

  4. Aspects et mesure de la qualité de vie : évolution et renouvellement des tableaux de bord métropolitains

    Directory of Open Access Journals (Sweden)

    Pierre J. Hamel

    2008-02-01

    Full Text Available La mesure de la qualité de vie à l’intérieur des espaces urbains préoccupe les administrations publiques depuis nombre d’années. Cet article passe en revue les modèles de mesure de la qualité de vie développés par les métropoles canadiennes. Il s’interroge sur l’évolution de ces modèles de mesure et sur leur capacité à rendre compte des différentes problématiques désormais associées à la notion de qualité de vie comme le développement social, l’environnement, la société du risque, les ambiances urbaines ou la compétitivité urbaine.For a number of years now, government bodies at all levels have been concerned with measuring quality of life within urban areas. This paper reviews the models used by Canada’s metropolises to measure quality of life. It examines how the models have evolved and their capacity to consider various issues which have become associated with the notion of quality of life, such as social development, environment, risk society, urban surroundings, or urban competitiveness.

  5. Banque d’instruments de mesure en recherche : Une innovation au service des membres chercheurs en sciences infirmières

    Directory of Open Access Journals (Sweden)

    Sylvie Le May

    2017-04-01

    Full Text Available Résumé : Introduction : Face aux difficultés que rencontrent ses enseignants et étudiants à retrouver des instruments de mesure valides dans les bases de données, le Réseau de Recherche en Interventions en Sciences Infirmières du Québec (RRISIQ a récemment choisi de développer une banque d’instruments de mesure accessible et bien documentée utilisant le logiciel bibliographique Zotero. Cet article a pour but de décrire la Banque d’instruments du RRISIQ, d’en exposer les défis et ses perspectives de développement. Description : La Banque comprend plus de 1400 liens ou références à des instruments de mesure reliés aux interventions cliniques, à l’organisation des services infirmiers et à la formation infirmière. L’utilisateur a accès à des références bibliographiques d’articles scientifiques sur les instruments, en anglais et en français. En naviguant dans la Banque, il clique sur l'article de son choix, obtenant ainsi une description bibliographique complète, dont une adresse web lui permettant d’accéder en ligne au plein texte. Résultats : La Banque d’instruments Zotero nécessite un faible coût d’entretien technique pour effectuer des sauvegardes, résoudre les difficultés et gérer les demandes d'accès. Elle est appréciée par ses utilisateurs. Discussion : La Banque prendra de l’ampleur dans les années à venir et des démarches sont actuellement réalisées par l’équipe pour la publiciser davantage auprès de ses membres et de leurs étudiants. L’équipe envisage de la rendre disponible à d’autres équipes de recherche du Québec.

  6. Measurement of resonance absorption integrals; Mesure des integrales de resonance d'absorption

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The measurements are carried out by the pile oscillator technique, without cadmium filter., in a spectrum rich in epithermal neutrons. The values are extrapolated to infinite dilution and corrected for the junction function. For the excess on the part in l/V, the following values are found: In: 3200 {+-} 70 b; Hf: 2080 {+-} 50; Ag: 670 {+-} 20; Co: 50 {+-} 5; Cs: 450 {+-} 15; Th: 87 {+-} 4. (author) [French] Les mesures sont effectuees par la methode d'oscillation, sans filtre de cadmium, dans un spectre riche en neutrons epithermiques. Les valeurs sont extrapolees a la dilution infinie et corrigees de la fonction de jonction. On trouve, pour l'exces sur la partie en l/v: In: 3200 {+-} 70 b; Hf: 2080 {+-} 50; Ag: 670 {+-} 20; Co: 50 {+-} 5; Cs: 450 {+-} 15; Th: 87 {+-} 4. (auteur)

  7. Study of thick, nuclear-compensated silicon detectors; Etude des detecteurs epais au silicium compense nucleairement

    Energy Technology Data Exchange (ETDEWEB)

    Le Coroller, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-09-01

    A study is made here, from the point of view of the realization and the performance, of thick nuclear-compensated silicon detectors. After recalling the need for compensation and reviewing the existing methods, the author describes in detail the controlled realization of thick detectors by nuclear compensation from the theoretical and experimental points of view. The practical precautions which should be observed are given: control of the homogeneity of the starting material, control of the evolution of the compensation, elimination of parasitic processes. The performances of the detectors obtained are then studied: electrical characteristics (current, life-time) on the one hand, detection and spectrometry of penetrating radiations on the other hand. The results show, that the compensated diodes having an effective thickness of two millimeters operate satisfactorily as detectors for applied voltages of about 500 volts. The resolutions observed are then about 2 per cent for mono-energetic electrons and about 4 per cent for the gamma; they can be improved by the use of a pre-amplifier of very low background noise. (author) [French] Les detecteurs epais au silicium compense nucleairement sont etudies ici du double point de vue realisation et performances. Apres un rappel sur la necessite de la compensation et les procedes existants, la realisation controlee des detecteurs epais par compensation nucleaire est decrite en detail sous l'aspect theorique et l'aspect experimental. On met en evidence les precautions a prendre dans la pratique: controle de l'homogeneite du materiau de base, controle de l'evolution de la compensation, elimination des processus parasites. On etudie ensuite les performances de detecteurs obtenus : caracteristiques electriques (courant, duree de vie) d'une part, d'autre part detection et spectrometrie des rayonnements penetrants. Les resultats montrent que les diodes compensees ayant une epaisseur utile de deux

  8. Study of thick, nuclear-compensated silicon detectors; Etude des detecteurs epais au silicium compense nucleairement

    Energy Technology Data Exchange (ETDEWEB)

    Le Coroller, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-09-01

    A study is made here, from the point of view of the realization and the performance, of thick nuclear-compensated silicon detectors. After recalling the need for compensation and reviewing the existing methods, the author describes in detail the controlled realization of thick detectors by nuclear compensation from the theoretical and experimental points of view. The practical precautions which should be observed are given: control of the homogeneity of the starting material, control of the evolution of the compensation, elimination of parasitic processes. The performances of the detectors obtained are then studied: electrical characteristics (current, life-time) on the one hand, detection and spectrometry of penetrating radiations on the other hand. The results show, that the compensated diodes having an effective thickness of two millimeters operate satisfactorily as detectors for applied voltages of about 500 volts. The resolutions observed are then about 2 per cent for mono-energetic electrons and about 4 per cent for the gamma; they can be improved by the use of a pre-amplifier of very low background noise. (author) [French] Les detecteurs epais au silicium compense nucleairement sont etudies ici du double point de vue realisation et performances. Apres un rappel sur la necessite de la compensation et les procedes existants, la realisation controlee des detecteurs epais par compensation nucleaire est decrite en detail sous l'aspect theorique et l'aspect experimental. On met en evidence les precautions a prendre dans la pratique: controle de l'homogeneite du materiau de base, controle de l'evolution de la compensation, elimination des processus parasites. On etudie ensuite les performances de detecteurs obtenus : caracteristiques electriques (courant, duree de vie) d'une part, d'autre part detection et spectrometrie des rayonnements penetrants. Les resultats montrent que les diodes compensees ayant une epaisseur utile de deux millimetres fonctionnent

  9. High speed pulsed magnetic fields measurements, using the Faraday effect; Mesures de champs magnetiques pulses rapides a l'aide de l'effet Faraday

    Energy Technology Data Exchange (ETDEWEB)

    Dillet, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-12-01

    For these measures, the information used is the light polarization plane rotation induced by the magnetic field in a glass probe. This rotation is detected using a polarizer-analyzer couple. The detector is a photomultiplier used with high-current and pulsed light. In a distributed magnet (gap: 6 x 3 x 3 cm) magnetic fields to measure are 300 gauss, lasting 0.1 {mu}s, with rise times {<=} 35 ns, repetition rate: 1/s. An oscilloscope is used to view the magnetic field from the P.M. plate signal. The value of the field is computed from a previous static calibration. Magnetic fields from 50 to 2000 gauss (with the probe now used) can be measured to about 20 gauss {+-} 5 per cent, with a frequency range of 30 MHz. (author) [French] Pour faire de telles mesures, on utilise comme information la rotation du plan de polarisation de la lumiere provoquee par le champ magnetique dans une sonde en verre. On detecte cette rotation au moyen d'un polariseur et d'un analyseur, qui sont regles a 45 deg. pour conserver un phenomene lineaire. Le detecteur est un photomultiplicateur travaillant en fort courant en lumiere pulsee. Dans un aimant distribue d'entrefer 6 x 3 x 3 cm, on obtient des champs magnetiques a mesurer de 300 gauss, durant 0.1 {mu}s, avec des temps de montee {<=} 35 ns; au taux de 1 fois par seconde. L'observation du champ se fait sur oscilloscope a partir du signal de plaque du P.M. La valeur absolue du champ est obtenue au moyen d'un etalonnage statique prealable. On peut ainsi mesurer a 20 gauss et {+-} 5 pour cent pres environ des champs magnetiques de 50 a 2000 gauss (avec la sonde actuelle) et avec une bande passante de 30 MHz. (auteur)

  10. Molten salts in nuclear reactors; Les sels fondus dans les reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Dirian, J; Saint-James, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Collection of references dealing with the physicochemical studies of fused salts, in particular the alkali and alkali earth halides. Numerous binary, ternary and quaternary systems of these halides with those of uranium and thorium are examined, and the physical properties, density, viscosity, vapour pressure etc... going from the halides to the mixtures are also considered. References relating to the corrosion of materials by these salts are included and the treatment of the salts with a view to recuperation after irradiation in a nuclear reactor is discussed. (author) [French] Bibliographie regroupant l'etude physico-chimique des sels fondus, en particulier des halogenures alcalins et alcalino-terreux. On etudie de nombreux systemes binaires, ternaires et quaternaires de ces halogenures avec des halogenures d'uranium, et de thorium. On etudie egalement les proprietes physiques des halogenures ou des melanges d'halogenures (densite, viscosite, tension de vapeur, etc...). On donne egalement des references quant a la corrosion des materiaux par ces sels, et le traitement de ceux-ci en vue de recuperation, apres irradiation dans un reacteur nucleaire. (auteur)

  11. Use of gamma spectroscopy in activation analysis; Utilisation de la spectrographie gamma dans l'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Brief review of the principles of activation analysis: calculation of activities, decay curves, {beta} absorption curves, examples of application. - Principle and description of the {gamma} spectrograph. - Practical utilisation of the {gamma} spectrograph: analysis by activation, analysis by {beta} - x fluorescence. - Sensitivity limit of the method and precision of the measurements. - Possible improvements to the method: {gamma} spectroscopy with elimination of the Compton effect. (author) [French] Bref rappel des principes de l'analyse par activation: calcul des activites, courbes de decroissance, courbes d'absorption {beta}, exemples d'utilisation. - Principe et description du spectrographe {gamma}. - Utilisation pratique de la spectrographie {gamma}: analyse par activation, analyse par fluorescence {beta} - x. - Limite de sensibilite de la methode et precision des mesures. - Ameliorations possibles de la methode: spectrographe {gamma} avec elimination de l'effet Compton. (auteur)

  12. Some results on the fluorescence of gases excited by high-energy charged particles; Quelques resultats concernant la fluorescence de gaz excites par des particules chargees de grande energie

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L; Lesureur, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The essential characteristics of rare gases for use as scintillators are as follows: a very brief period of luminescence, generally less than 10{sup -8} s; a linear response as a function of the energy lost by the nuclear particle in the gas, even in the case of strongly ionising particles (fission fragments). In the gaseous or condensed state therefore, they are of great interest in nuclear physics. (author) [French] Les caracteristiques essentielles des gaz rares en tant que scintillateurs sont: une duree de luminescence tres breve, inferieure a 10{sup -8} s en general; une reponse lineaire en fonction de l'energie perdue par la particule nucleaire dans le gaz, meme dans le cas de particules fortement ionisantes (fragments de fission). A l'etat gazeux ou condense, ils presentent donc un grand interet en physique nucleaire. (auteur)

  13. The pulsed neutron method applied to the determination of the nuclear constants of graphite (1961); La methode des neutrons pulses appliquee a la determination des constantes nucleaires du graphite (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Lalande, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-07-01

    A method for determining the nuclear constants {sigma}{sub a} and {lambda}{sub t} of a moderator is described. The disappearance of a burst of neutrons introduced into a finite medium is studied as a function of time. This decrease in the thermal neutron density is the product of two exponentials; one representing the absorption, the other the leakage. By varying one or other of these factors, the constants of the factor left unvaried can be determined, and from this the nuclear constant values are deduced. (author) [French] On decrit une methode permettant de determiner les constantes nucleaires {sigma}{sub a} et {lambda}{sub t} d'un moderateur. On etudie la decroissance dans le temps d'une bouffee de neutrons introduite dans un milieu fini. Cette decroissance de la densite en neutrons thermiques est le produit de deux exponentielles; l'une represente l'absorption, l'autre les fuites. Par variation de l'un ou l'autre de ces facteurs, on determine les constantes du facteur laisse invariant dont on deduit les valeurs des constantes nucleaires. (auteur)

  14. Problems related with the power regulation of reactors by physico-chemical methods, and the behaviour of water and heavy water in nuclear reactors; Comportement de l'eau et de l'eau lourde dans les reacteurs nucleaires et problemes de la regulation de puissance par voie physico-chimique

    Energy Technology Data Exchange (ETDEWEB)

    Dolle, L; Conan, D; Dirian, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Experience of the CEA heavy water reactors and a systematic study of the radiolytic decomposition of water in the core of swimming-pool reactors are described. Setting up of reactivity control by physico-chemical methods. Reactivity control by homogeneous poisoning of the reactor A comparison of the evolution of xenon poisoning with the residual anti reactivity of the poison in solution during its nuclear consumption establishes the programme which must govern the variation in its concentration if the exact compensation is to be produced The behaviour of the poison towards the reactor materials under the particular operational conditions must be taken into account. Radiolytic decomposition of water in the reactors in the presence of soluble poisons: A study of the effect of certain chemically inert salts, present in small concentrations in the water, on its radiolytic decomposition rate, has led to some new results which are discussed. The choice of a soluble poison is justified on the basis of the above results. Reactivity control by the use of a gaseous absorbent The use of a gas control rod circuit for compensation purposes, in place of solid control rods is described. The use of soluble poisons in the moderator to compensate the xenon effect, and of a gaseous absorbent in a circuit known as a gas control rod form original aspects of the reactivity control in the reactor EL 4. (authors) [French] L'observation du comportement de l'eau et de l'eau lourde dans les reacteurs en exploitation, contribue au fonctionnement sur de ceux-ci et oriente certaines etudes relatives aux techniques de controle de la reactivite par mise en oeuvre de poisons solubles. L'utilisation de poisons nucleaires dissous dans l'eau du reacteur entraine une pollution chimique de celle-ci. Les conditions d'emploi permettant d'eviter les effets indesirables de cette pollution sont etudiees. Les problemes analytiques - bien qu'importants - ne sont pas abordes dans le cadre de la communication

  15. The United States Atomic Energy Commission Programme of Nuclear Materials Management; Le Programme de Gestion des Matieres Nucleaires Applique par L'USAEC; Programma komissii po atomnoj ehnergii ssha v oblasti obrashcheniya s yadernymi materialami; El Programa de Administracion de Materiales Nucleares de la Comision de Energia Atomica de los Estados Unidos

    Energy Technology Data Exchange (ETDEWEB)

    George, D. E. [United States Atomic Energy Commission, Washington, DC (United States)

    1966-02-15

    Nuclear materials management as conceived by the US Atomic Energy Commission is defined and its development traced from 1943 to the present time. The general programme is outlined and its principal features discussed. Emphasis is placed on administration of those portions of the USAEC programme which pertain to the development and maintenance of quantity data, the establishment of internal controls and the evaluation of performance. The current techniques whereby transfer data are recorded and processed within the USAEC are discussed in some detail, as are the techniques for presentation of material balance reports which periodically summarize the transactions and the results of operations. The techniques used by the USAEC to ascertain the effectiveness of the nuclear materials management programmes of its operating contractors are also discussed. In addition to material being held by contractors which operate USAEC-owned plants and laboratories, there are large quantities of special nuclear material held under a wide variety of financial and administrative arrangements, e.g. under lease, private ownership, under contract with the USAEC where the user is financially liable for losses, as well as those where the risk of losses is taken by the USAEC. This divergence of circumstances causes significant variation in the emphasis and approach used by the AEC and this variation is noted. A brief summary of unresolved problem areas concludes the presentation. (author) [French] L'auteur definit la gestion des matieres nucleaires telle qu'elle est concue par l'USAEC et decrit son evolution depuis 1943 jusqu'a nos jours. Il expose le programme general et discute ses principales caracteristiques. Le memoire souligne les aspects administratifs des parties du programme qui ont trait a la preparation et la tenue a jour des donnees relatives aux quantites, a l'application de controles internes et a l'evaluation de l'efficacite des mesures prises. L'auteur commente en detail la

  16. The activity of {gamma}-emitters as measured by ionisation chambers the determination of the specific emission coefficient {gamma} for some radio-elements (1961); Mesure de l'activite des emetteurs {gamma} par chambre d'ionisation. Determination du coefficient specifique d'emission {gamma} de quelques radioelements (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The object of this work is to study techniques of measurement using the gamma ionisation chamber, making it possible either to measure the activities of radioactive sources, or to determine the specific emission coefficient {gamma} (or the coefficient K) of a given radioelement. The ionisation chambers studied belong to two categories: graphites cavity-chambers, and 4 {pi} {gamma} chambers. For the cavity-chamber measurements, the different correction factors of which account must be taken have been calculated, in particular the geometric and hygrometric corrections. The absorption and auto-absorption corrections have led to the introduction of the notion of the 'effective energy {gamma}' of a radioelement. In the case of 4 {pi} {gamma} chambers, it has been shown that appropriately shaped electrodes make it possible to improve their performances. One of the chambers described permits the measurement of {beta} emitters using the associated Bremsstrahlung. In order to measure the K coefficient of some radioelements, it has been found useful a 4 {pi} {gamma} chamber with graphite walls, the measurement being carried out by comparison with a radium standard. The validity of the method was checked with radioelements for whom the K coefficient values are well-known ({sup 24}Na, {sup 60}Co, {sup 131}I, {sup 198}Au). For other radioelements, the following values were obtained (expressed in r cm{sup 3} mc{sup -1} h{sup -1}): {sup 51}Cr: 0,18; {sup 56}Mn: 8,8; {sup 65}Zn: 3,05; {sup 124}Sb: 9,9; {sup 134}Cs: 9,3; {sup 137}Cs: 3,35; {sup 141}Ce: 0,46; {sup 170}Tm: 0,023; {sup 192}Ir: 24,9; {sup 203}Hg: 1,18; These values have been corrected for the contribution to the dose of the fluorescent radiation which may be emitted by the source, except in the case of Tm{sup 170}. In the last part of this work, the performances of the different electro-metric devices used were compared. (author) [French] Le but de ce travail est d'etudier les techniques de mesure par

  17. Application of a proportional counter to some particular cases of {alpha} measurements; Applications d'un compteur proportionnel a quelques cas particuliers de mesures {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Ferret, J; Gasc, M T; Le Du, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    I - A measurement method based on {alpha} {gamma} coincidences is used for activity measurements on {sup 241}Am in the presence of a strong {alpha} activity due to Pu. The sensitivity of the apparatus makes it possible to detect: less than 10{sup -7} {mu}C {sup 241}Am in the presence of a Pu activities several hundred times greater. II - The same equipment has been used for {alpha} measurements on {alpha}-emitting sources in the presence of very strong {beta} and {gamma} activities. In particular results are given for {alpha}-activity measurements on powder samples. It is even possible in these conditions, to detect or measure {sup 241}Am. III - The equipment makes possible also: - the absolute calibration of a pure {sup 241}Am source - {sup 237}Np measurements - simultaneous measurements of {alpha}, {beta} and {gamma} activities in solid samples in various forms. IV - The assembly includes a small-size proportional counter operating in conjunction with a {gamma} probe, together with auxiliary electronic equipment (stabilized high voltages, amplifiers, a coincidence unit, a sealer). (authors) [French] I - Une methode de mesures par coincidences {alpha} {gamma} est utilisee pour des mesures d'activite de {sup 241}Am en presence d'activite {alpha} (due au Pu) importante. -La sensibilite de l'appareillage permet de deceler: moins de 10{sup -7} {mu}C {sup 241}Am dans les activites {alpha} Pu plusieurs centaines de fois plus importantes. II - Le meme appareillage a ete utilise pour des mesures {alpha} sur des sources emettrices {alpha} en presence d'activites {beta} et {gamma} tres importantes. En particulier des mesures d'activite {alpha} sur des echantillons de poudre sont exposees. Il est meme possible, dans ces conditions, de deceler ou mesurer {sup 241}Am. III - L'ensemble permet egalement: - l'etalonnage absolu d'une source de {sup 241}Am pur - des mesures de {sup 237}Np - des mesures simultanees d'activites {alpha}, {beta} et {gamma} dans des echantillons solides

  18. Appareillage automatisé de mesure simultanée du pouvoir thermoélectrique et de la conductivité électrique. Application à l'étude de couches polymères semi-conductrices

    Science.gov (United States)

    Moliton, A.; Ratier, B.; Moreau, C.; Froyer, G.

    1991-05-01

    In this paper, we present an automatized system for simultaneous measurement of conductivity σ, and thermoelectric power S : measurements are allowed for temperatures ranging from 130 K to 360 K on brittle semiconductor layers. As an example of the application, results obtained in the case of polymer (PPP) layers implanted with Na ions are presented : with high energy implantation (E = 250 keV) we observe only a defect semiconduction of p type while at low energy (30 keV) an electronic n type conduction appears. Nous présentons dans cet article un système de mesure simultanée de la conductivité σ, et du pouvoir thermoélectrique S : il permet des mesures en fonction de la température (entre 130 K et 360 K) dans le cas de couches semi-conductrices relativement fragiles. A titre d'application, nous indiquons les résultats que nous avons obtenus dans le cas de couches polymères (PPP) implantées avec des ions sodium: alors que seule une semi-conduction par défaut est générée par de fortes énergies d'implantation (E = 250 keV ), il apparaît une semiconduction induite par le dopage n lors d'implantations à basse énergie (E = 30 keV ).

  19. Contribution to the activation analysis of the rare gases. Contribution to the analysis of carbon monoxide and water vapour in gases (1963); Contribution a l'analyse par activation des gaz rares. Contribution a l'analyse de l'oxyde de carbone et de la vapeur d'eau dans les gaz (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Diebolt, J [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-15

    In the present work, we have applied radioactive analysis to the general technique of rare gas separation. This separation is carried out on active charcoal, at constant pressure. The desorption of the gas is caused by an increase in the initial temperature of adsorption. These separations are quantitative and can be confirmed by chemical analysis. The volumes of desorbed gas are measured by radioactive counting. We have also used radioactivation to study the reduction of palladous chloride by carbon monoxide. Since this reduction is quantitative, we can have a knowledge of the mass of palladium reduced by measuring its activity. We have used the property which have organic chlorides of being hydrolysed by water vapour and of liberating hydrochloric acid to study quantitatively the amount of water vapour which a gas contains. The hydrochloric acid formed is measured by activation of the chlorine in the acid. (author) [French] Dans les travaux que nous presentons, nous avons applique l'analyse par radioactivation, a la technique generale de separation des gaz rares. Cette separation est faite sur charbon active, a pression constante. La desorption des gaz est provoquee par une augmentation de la temperature initiale d'adsorption. Ces separations sont quantitatives, et peuvent etre exploitees par l'analyse chimique. Les volumes de gaz dedorbes sont mesures par comptage de la radioactivite. Nous avons egalement utilise la radioactivation pour l'etude de la reduction du chlorure palladeux par l'oxyde de carbone. Cette reduction etant quantitative, nous pouvons connaitre la masse de palladium reduit par la mesure de son activite. Nous avons exploite la propriete que possede un chlorure organique d'etre hydrolise par la vapeur d'eau et de liberer de l'acide chlorhydrique pour etudier quantitativement la vapeur d'eau contenue dans un gaz. L'acide chlorhydrique forme est mesure par l'activation du chlore de l'acide. (auteur)

  20. Perfection of the individual photographic emulsion dosimeter; Perfectionnements dans la dosimetrie individuelle par emulsion photographique

    Energy Technology Data Exchange (ETDEWEB)

    Soudain, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A photographic dosimeter making possible the measurement of {gamma} radiation doses of from 10 mr up to 800 r by means of 3 emulsion bands of varying sensitivity stuck to the same support is described. The dosimeter has also a zone for marking and a test film insensitive to radiation. This requires a photometric measurement by diffuse reflection an d makes it possible to measure doses with an accuracy of 20 per cent. (author) [French] On decrit un dosimetre photographique permettant la mesure des doses de rayonnement {gamma} depuis 10 mroentgens jusqu'a 800 roentgens, au moyen de trois bandes d'emulsions de sensibilites differentes collees sur le meme support. Le dosimetre comporte egalement une plage de marquage et un temoin de developpement insensibles au rayonnement. Ceci impose la mesure photometrique par reflexion diffuse et permet l'appreciation visuelle des doses a 20 pour cent pres. (auteur)

  1. Conference Proceedings of Engine Cyclic Durability by Analysis and Testing

    Science.gov (United States)

    1984-01-01

    mesurant l’amplitude par jauge extensom6trique. Essais de survitesse *~V Toujours pour les rotors, des essais de survitesse sont effectuds au puits sous...statiques de vol 616mentaire de laboratoire temp~ratures Y: 7 Certification Mesures par mesure des D~finition de Easais aur Essais cyoliques -*- jauges ...fins, et la photo-61asticit6. Los contraintes ainsi calculdes sont vdrifi~es A l’aide do mesures par jauges . 18-5 Les zones jugdes critiques (fig. 8

  2. L'analyse par activation de neutrons de réacteur

    Science.gov (United States)

    Meyer, G.

    2003-02-01

    Quand les neutrons traversent la matière, certains sont transmis sans interaction, les autres interagissent avec le milieu traversé par diffusion et par absorption. Ce phénomène d'absorption est utilisé pour se protéger des neutrons, mais aussi pour les détecter; il peut également être utilisé pour identifier les noyaux “absorbants" et ainsi analyser le milieu traversé. En effet par différentes réactions nucléaires (n,γ), (n,p), (n,α), (n,fission), on obtient des noyaux résiduels qui sont souvent radioactifs; on dit que l'échantillon est “activé". Si l'on connaît le rendement d'activation et donc le pourcentage de noyaux ainsi “transmutés", les mesures de radioactivité induite vont permettre de déterminer la composition de l'échantillon irradié. Cette méthode dite d'analyse par activation neutronique est pratiquée depuis la découverte du neutron. Elle a permis grâce à sa sélectivité et à sa sensibilité d'avoir accès au domaine des traces et des ultra-traces dans des champs d'application très divers comme la métallurgie, l'archéologie, la biologie, la géochimie etc...

  3. Mesure de la Polarisation des Lambda Produits dans les Collisions Positron-Electron AU Lep a L'aide du Detecteur Opal

    Science.gov (United States)

    Vandenplas, Denis

    Le Modele Standard est le cadre theorique general qui, jusqu'a present, a permis l'interpretation de tous les resultats experimentaux en physique des hautes energies. Cette theorie decrit, entre autres, la production d'une paire de particules elementaires, formee d'un quark et d'un antiquark, a partir de la desintegration de l'un des bosons mediateurs de l'interaction faible, le Z^0. Cependant, dans ce cas precis, la transformation subsequente des quarks primaires en particules reelles, un processus appele hadronisation, n'est decrite qu'a l'aide de modeles phenomenologiques. Afin de sonder les mecanismes de l'hadronisation, cette these presente la mesure du transfert du spin d'un quark etrange primaire a une particule appelee Lambda lors des desintegrations hadroniques du Z^0. L'etude a ete realisee dans le cadre de la collaboration OPAL, une des quatre experiences menees au collisionneur LEP, la ou des electrons et des positrons sont acceleres jusqu'a une energie commune, sqrt{s} = {rm E_ {cm}}, voisine de l'energie de production du rm Z^0, M_{Z ^0} egale a 91.3 GeV. La theorie electrofaible precise la direction du spin, c'est-a-dire la polarisation, d'un quark etrange primaire provenant de la desintegration d'un Z ^0. Quant a lui, le modele des quarks etablit que l'orientation du spin d'un Lambda est directement reliee a la polarisation du quark etrange dont il provient. La question est de determiner dans quelle mesure la polarisation du quark primaire est transmise au Lambda a la suite du processus de l'hadronisation, decrit dans le cadre de la ChromoDynamique Quantique. Une estimation, qui tient compte de tous ces differents aspects theoriques, evalue a 30% la polarisation des Lambda dont l'impulsion est superieure a 15 GeV/c. La mesure experimentale de la polarisation repose sur l'identification des Lambda a partir de la reconstitution de la desintegration Lambdato ppi^-. Ce processus, qui se deroule par le biais de l'interaction faible, viole la parite car

  4. Measurement of the local void fraction at high pressures in a heating channel; Mesure du taux de vide a haute pression dans un canal chauffant

    Energy Technology Data Exchange (ETDEWEB)

    Martin, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Void fraction measurements were made in two phase flow boiling systems at high pressures in a uniformly heated, rectangular channel with a high aspect ratio. The local void fraction values were calculated from measurements of the absorption of a thin collimated X-ray beam (2 mm x 0.05 mm). The mean void fraction in a horizontal section results from integration of the local values across the section. At a fixed measuring station the quality and- void fraction were varied by changing the heat flux, flow rate and pressure systematically. Two channels were used differing in length and thickness (150.8 cm x 5.3 cm x 0.2 cm and the significant features of this study are: -1) The void fraction measurements are among the first obtained at such high pressure (80 to 140 kg/cm{sup 2}); -2) In the experimental region under consideration the measurements are systematic and numerous enough to allow accurate interpolations: mass velocity from 50 to 220 g/cm{sup 2}.s, heat flux from 40 to 170 W/cm{sup 2} and calculated steam quality from -0.2 to 0.2; -3) Many tests were performed under local boiling conditions with the mean temperature of the fluid below the saturation temperature; and -4) These results were compared to the predictions of certain models presented in the literature and simple empirical formulae were developed to fit the experimental results. (author) [French] Des mesures de taux de vide ont ete effectuees sur un ecoulement eau-vapeur a haute pression dans un canal vertical, de section rectangulaire tres allongee et chauffe a flux uniforme. Les valeurs du taux de vide local sont obtenues a partir des mesures de l'absorption d'un faisceau de rayons X finement collimate (2 mm x 0,05 mm). La valeur du taux de vide moyen dans une section droite s'en deduit par integration. Cette section droite ou sont realisees les mesures est fixe et, a pression, debit et flux donnes, les variations du titre et du taux de vide sont obtenues par variations de l'enthalpie d'entree. Deux

  5. Comparison of fission probabilities with emission of long range particles under the action of slow and fast neutrons on various materials; Probabilites comparees de fission avec emission de particules de long parcours pour divers materiaux sous l'action des neutrons lents et rapides

    Energy Technology Data Exchange (ETDEWEB)

    Netter, F; Faraggi, H; Garin-Bonnet, A; Julien, J; Corge, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Turkiewicz, J [Institut de Recherches Nucleaire de Varsovie (Poland)

    1958-07-01

    parcours, sous l'action de neutrons de diverses energies: neutrons thermiques, neutrons de pile, neutrons produits avec l'accelerateur Van de Graaff par la reaction des protons sur le tritium. Les mesures sont effectuees: 1) a l'aide de plaques photographiques, en soumettant a l'action des neutrons une couche de matiere fissile, accolee contre une emulsion nucleaire Ilford de 100 microns; une feuille d'etain appliquee entre la plaque et la couche arrete les {alpha} et les fragments de fission. On distingue dans l'emulsion par un developpement approprie les trajectoires de particules de long parcours des trajectoires de protons de recul provenant soit des neutrons de fission, soit des neutrons primaires rapides. La frequence comparee des trajectoires des particules de long parcours et des reculs dus aux neutrons de fission fournit une mesure de la section efficace de fission avec emission de particules de long parcours relativement au produit de la section efficace de fission par le nombre moyen de neutrons emis par fission. Des precautions sont prises peur eliminer le role des neutrons thermiques dans les mesures par neutrons rapides. 2) a l'aide d'un systeme de chambre d'ionisation et compteur proportionnel, on mesure le taux de coincidence entre les impulsions produites par la particule de long parcours et celles produites par un des fragments de fission, relativement au taux de comptage des fragments de fission. (auteur)

  6. Experimental determination of the back scattering factor in X-ray microanalysis; Determination experimentale du facteur de retro-diffusion en microanalyse par emission X

    Energy Technology Data Exchange (ETDEWEB)

    Derian, J C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-06-01

    This paper describes the first experimental method which has fixed the relative value of the X-ray loss by electron back scattering. Measurements have been performed, using gold, copper and aluminium specimens and accelerating voltages from 10 to 30 kV. Our experimental results, although higher than back scattering factor values calculated before, agree fairly well with those obtained by a Monte-Carlo calculation, using recent experimental measurement on thin films. The higher values obtained here, show that the compensation between deceleration and back scattering effects is better: the discrepancy from a linearity law is then probably weaker than it has been generally shown previously. (author) [French] Le memoire decrit la premiere methode experimentale ayant permis de determiner l'importance relative de la fraction du rayonnement X perdue par retrodiffusion des electrons. Les mesures ont porte sur l'or, le cuivre et l'aluminium entre 10 et 30 kV. Les resultats, sensiblement superieurs aux estimations anterieures, sont en bon accord avec ceux deduits, par la methode de Monte-Carlo, des recentes mesures sur les lames minces. Les valeurs plus elevees du facteur de retrodiffusion mises ainsi en evidence, conduisent a une meilleure compensation entre les effets de ralentissement et de retrodiffusion: l'ecart a une simple loi de proportionnalite par effet de difference de nombre atomique est ainsi probablement plus faible qu'on ne le pensait generalement jusqu'ici. (auteur)

  7. Burnup determination of power reactor fuel elements by gamma spectrometry; Determination par spectrometrie {gamma} du taux d'irradiation des elements combustibles des reacteurs de puissance

    Energy Technology Data Exchange (ETDEWEB)

    Robin, M; Jastrzeb, M; Boisliveau, S; Boyer, R; Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    This report describes a method for determining by {gamma} spectrometry the burn up and the specific power of fuel elements irradiated in power reactors. The energy spectrum of {gamma} rays emitted by fission products is measured by means of a simple equipment using a sodium iodide detector and a multichannel analyzer. In order to extract from the spectrum a quantity proportional to the burn up, it is necessary to: - isolate an activity specific of one emitter,- give the same importance to fissions in uranium and plutonium - take into account the radioactive decay during and after irradiation. One hundred fuel elements were studied and burn up values obtained by {gamma} spectrometry are compared to results given by chemical analyses. Preliminary measurements show that the accuracy of the results is greatly increased by the use of a germanium detector, due to its good resolution. (authors) [French] Ce rapport expose une methode de determination par spectrometrie {gamma} du taux d'irradiation et de la puissance specifique des elements combustibles irradies dans les reacteurs de puissance. Une installation simple utilisant un detecteur d'iodure de sodium et un selecteur multicanaux mesure le spectre en energie du rayonnement {gamma} emis par les produits de fission. Afin d'extraire du spectre une quantite proportionnelle au taux de combustion, il faut: - isoler une activite specifique a un emetteur, - donner la meme importance aux fissions survenues dans l'uranium et le plutonium, - prendre en compte la decroissance radioactive pendant et apres l'irradiation. Les mesures ont porte sur une centaine d'elements combustibles et les taux de combustion obtenus par spectrometrie {gamma} sont compares aux resultats des analyses chimiques. Des mesures preliminaires montrent que l'utilisation d'un detecteur de germanium augmente considerablement la precision des resultats, en raison de son excellente resolution. (auteurs)

  8. Results and interpretation of spectral indices measurements made with AQUILON; Resultats et interpretation de mesures d'indices de spectre dans aquilon

    Energy Technology Data Exchange (ETDEWEB)

    Frichet, J P; Mougey, J N; Naudet, R; Taste, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    This report deals with a set of spectral indices measurements made in the heavy water reactor Aquilon on lattices constituted by massive fuel elements of dia. 29,2 mm. The fuel elements were made either of natural uranium or of slightly depleted or slightly enriched uranium, or of an uranium-plutonium alloy. The measurements were carried out for various lattice pitches (square pitch from 110 to 210 mm) and in certain cases for various temperatures (from 20 to 80 deg. C). The results are compared to calculated values obtained by using the latest advances of the thermalization theory developed at Saclay applied to the moderation by heavy water. (authors) [French] Ce rapport est consacre a un ensemble de mesures d'indices de spectre realisees dans la pile a eau lourde Aquilon sur des reseaux d'elements combustibles pleins, de 29,2 mm de diametre. Ces combustibles se composaient ou bien d'uranium naturel, ou bien d'uranium tres legerement appauvri ou enrichi, ou bien d'un alliage uranium plutonium. Les mesures ont ete effectuees pour toute une serie de pas de reseaux (pas carre 110 a 210 mm), certaines d'entre elles a plusieurs temperatures (20 a 80 deg. C). Les resultats des mesures sont compares a des valeurs calculees obtenues en utilisant les plus recents developpements de la theorie de la thermalisation mise au point a Saclay, appliques au cas de la moderation par l'eau lourde. (auteurs)

  9. La gestion par affaire et pilotage de la performance des organisations industrielles

    OpenAIRE

    Pendariees, Michel

    2006-01-01

    International audience; « Dans les systèmes industriels où les produits sont conçus et réalisés en fonction des spécifications des clients, la notion d'affaire est l'entité de base de la gestion industrielle » . Aujourd'hui, la recherche de solutions globales « sur mesure », prime sur la fourniture d'un catalogue de « belles solutions », comme réponse au client. Pour être performante, l'entreprise industrielle doit s'organiser par « affaire ». Ce qui lui permet de mieux s'adapter et maîtriser...

  10. Quantitative dosing by nuclear magnetic resonance; Dosages quantitatifs par resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, I [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measurement of the absolute concentration of a heavy water reference containing approximately 99.8 per cent of D{sub 2}O has been performed, by an original magnetic resonance method ('Adiabatic fast passage method') with a precision of 5.10{sup -5} on the D{sub 2}O concentration. (author) [French] La determination du titre absolu d'une eau lourde etalon de teneur approximative de 99,8 pour cent de D{sub 2}O a pu etre effectuee par une methode originale de resonance magnetique ('Methode de passage rapide adiabatique') a une precision de 5.10{sup -5} sur le titre de D{sub 2}O. (auteur)

  11. The nuclear power stations of the French atomic energy programme (1960); Les centrales nucleaires de puissance du programme francais (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Leduc, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Roux, J P [Electricite de France (EDF), 75 - Paris (France)

    1960-07-01

    After recalling the entry of nuclear energy into energy production in France, the paper emphasizes the evolution of techniques applied in the designing of French nuclear power plants and describes the means employed for reducing costs per kWh of EDF2 and EDF3 compared with EDF1: the electric power per ton of uranium varies from 493 kW/t for EDF1 to 970 kW/t for EDF3. For this purpose the thermal power and electric power of units are changed respectively from 290 MWt for EDF1 to 1200 or 1600 MWt for EDF3 and from 28 to 250 MW. The results are obtained by an improvement in neutronic characteristics, developments in nuclear fuel technology, and simplification of the system of charging the reactor, whose means of maintenance are increased; the EDF2 heat-exchangers have been so designed as to increase the unit power of the elements, which will attain 9 MWt, as against 3 for EDF1. For EDF3 an advance project forecasts a thermodynamic layout with only one pressure stage. The paper ends with a description of the burst-slug detection systems, and an appendix gives a detailed comparative table of EDF1, EDF2 and EDF3 plant characteristics. (author) [French] Apres avoir rappele l'integration de l'energie nucleaire parmi les moyens de production de l'energie en France, les auteurs se penchent surtout sur l'evolution des techniques appliquees dans l'equipement des centrales nucleaires francaises et decrivent les moyens mis en oeuvre pour reduire les prix de revient du kWh d'EDF2 et d'EDF3 par rapport a EDF1: la puissance electrique par tonne d'uranium varie de 493 kW/t pour EDF1 a 970 kW/t pour EDF3. C'est dans ce but que les puissances thermiques et la puissance unitaire des groupes turbo-alternateurs passent respectivement de 290 MWt pour EDF1 a 1200 ou 1600 MWt pour EDF3 et de 82 a 250 MW. Les resultats sont obtenus par une amelioration des caracteristiques neutroniques, des progres realises sur la technologie des elements combustibles, une simplification du systeme de

  12. Measurement of the electron density of a plasma by interferometry with a He - Ne laser ({lambda} = 3.39 {mu}); Mesure de la densite electronique d'un plasma par interferometrie avec un laser He - Ne ({lambda} = 3.39 {mu})

    Energy Technology Data Exchange (ETDEWEB)

    Belland, P [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The characteristics of the He-Ne gas laser used in a simple interferometric technique have been studied. After passing through the plasma, the beam is reflected back into the laser cavity, and the intensity of the laser itself, modulated by this optical feedback, is used to observe the fringes. Furthermore, owing to the coupling of the two laser transitions 0.63{mu} (red) and 3.39{mu} (infra red), interferences in the infra red can be detected by a simple photomultiplier monitoring the red line. This method has been applied to two plasma machines (E.P.P.E. and SABLIER) for spatial and temporal measurements of the mean electron density. (author) [French] Nous avons etudie les caracteristiques d'un laser a gaz He-Ne utilise dans une technique simple d'interferometrie. La lumiere qui traverse le plasma est reinjectee dans le laser, et l'intensite propre de celui-ci, modulee par cette reinjection, sert a observer les franges. De plus, a cause du couplage des deux transitions laser: 0.63{mu} (rouge) et 3.39{mu} (infrarouge), les interferences dans l'infrarouge peuvent etre detectees par un simple photomultiplicateur sensible au rouge. Nous avons applique cette methode a deux machines a plasma (E.P.P.E. et SABLIER) pour la mesure de la densite electronique moyenne en fonction du temps et de l'espace. (auteur)

  13. 4{pi} proportional counter for absolute measurement of {beta}-emitters; Compteur 4{pi} proportionnel destine a la mesure absolue d'emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Perolat, J P; Laine, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The 4{pi} counter is commonly used to measure the activity of {beta} sources, the one we describe does not advance a new conception but the issue of several years of investigations. The apparatus presents good performances about the qualities commonly required in that kind of counter: detection efficiency, plateau and dead time. Moreover technical characteristics give a great flexibility in use, particularly a possibility of adaptation in a {beta},{gamma} coincidence unit. (authors) [French] Le compteur 4{pi} proportionnel est couramment, utilise pour mesurer l'activite de sources {beta}, celui que nous decrivons ne represente pas une conception nouvelle, mais plutot l'aboutissement de plusieurs annees d'etudes. Cette installation presente des performances satisfaisantes en ce qui concerne les qualites habituellement requises dans ce type de compteur: l'efficacite de detection, le palier et le temps mort. En outre, certaines caracteristiques techniques qui lui sont propres lui conferent une grande souplesse d'utilisation, en particulier la possibilite d'adaptation a un ensemble de mesures par coincidences 4{pi} {beta} {gamma}. (auteurs)

  14. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  15. Integral measurements of lattice properties in the natural uranium-graphite critical facility Marius; Mesures globales de reseaux a graphite dans l'empilement critique marius

    Energy Technology Data Exchange (ETDEWEB)

    Cogne, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    A systematic study of natural uranium-graphite lattices has been undertaken in the critical facility MARIUS, which was built in 1959 in Marcoule. Integral measurement of lattice properties are carried out by the progressive replacement method. This report describes the experimental methods, the analysis of the experiments and the results obtained for lattices with pitches ranging from 192 to 317 mm and fuel elements with cross sections ranging from 6 to 20 cm{sup 2}. The principles of correlation of the results are also outlined. Additional experimental results are also given, pertaining to the determination of the anisotropy, of both the axial and the radial migration areas, and of the age in graphite. (author) [French] L'empilement critique MARIUS, construit en 1959 a Marcoule, a ete utilise pour l'etude systematique des reseaux a graphite-uranium naturel. Les mesures globales de reseaux sont faites par la methode de remplacement progressif. On decrit ici les methodes experimentales utilisees pour ces mesures globales, les principes du depouillement et les resultats obtenus pour des pas de 192 a 317 mm et des combustibles de 6 a 20 cm{sup 2} d'uranium naturel. On donne d'autre part le principe de correlation des mesures. Un certain nombre de resultats experimentaux complementaires sont donnes, en permettant de determiner l'anisotropie, les aires de migration axiale et radiale, l'age dans le graphite. (auteur)

  16. Quantitative dosing by nuclear magnetic resonance; Dosages quantitatifs par resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, I. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measurement of the absolute concentration of a heavy water reference containing approximately 99.8 per cent of D{sub 2}O has been performed, by an original magnetic resonance method ('Adiabatic fast passage method') with a precision of 5.10{sup -5} on the D{sub 2}O concentration. (author) [French] La determination du titre absolu d'une eau lourde etalon de teneur approximative de 99,8 pour cent de D{sub 2}O a pu etre effectuee par une methode originale de resonance magnetique ('Methode de passage rapide adiabatique') a une precision de 5.10{sup -5} sur le titre de D{sub 2}O. (auteur)

  17. Measurement of the C / H ratio using neutrons; Mesure du rapport C / H au moyen des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Ricci, H [Universite de Lima (Peru)

    1960-07-01

    A probe made up of a Ra ({alpha}, n) Be neutron source and a proportional counter filled with boron trifluoride has been used to measure the C/H ratio in hydrocarbons. The intensity of the thermal neutron flux in the neighbourhood of the detector increases with the concentration of the hydrocarbon hydrogen surrounding it. By measuring the density it is possible to deduce the C/H ratio. It is thus possible to evaluate the C/H ratio with a precision equal to that given by the {beta}-ray transmission method. The errors arising from the chemical nature of the hydrocarbon can be reduced to a minimum. This method has the advantage of allowing the measurement of the C/H ratio of hydrocarbons contained in recipients or thick steel tubing by means an independent portable apparatus. (author) [French] Une sonde constituee d'une source de neutrons Ra ({alpha}, n) Be et d'un compteur proportionnel a remplissage de trifluorure de bore a ete utilisee pour mesurer le rapport C/H dans les hydrocarbures. Le flux des neutrons thermiques au voisinage du detecteur est d'autant plus intense que la concentration en hydrogene de l'hydrocarbure qui entoure la sonde est plus elevee. Une mesure de densite permet d'en deduire le rapport C/H. On peut ainsi evaluer le rapport C/H avec une precision aussi bonne que celle que l'on obtient par transmission de rayons {beta}. Les erreurs provenant de la nature chimique de l'hydrocarbure peuvent etre minimisees. Cette methode presente l'avantage de permettre la mesure du rapport C/H d'hydrocarbures contenus dans des recipients ou des canalisations epaisses en acier a l'aide d'un appareil exterieur transportable. (auteur)

  18. Overhauser effect in metallic lithium; Effet Overhauser dans le lithium metallique

    Energy Technology Data Exchange (ETDEWEB)

    Gueron, J.; Ryter, Ch. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre d' Etudes Nucleaires de Saclay (France)

    1960-07-01

    The Overhauser effect has been observed: a) at ordinary temperatures, by measuring the increase in the nuclear resonance signal of Li{sup 7}; b) at the temperature of liquid helium, by observing the electron resonance shift due to the secular part of the electron-nucleus coupling. The metallic lithium particles are produced by irradiating lithium hydride with thermal neutrons. Reprint of a paper published in Physical Review Letters, vol. 3, no. 7, 1959, p. 338-340 [French] L'effet Overhauser est mis en evidence: a) a la temperature ordinaire, en mesurant l'augmentation du signal de resonance nucleaire du Li{sup 7}; b) a la temperature de l'helium liquide, en observant le deplacement de la raie de resonance electronique du a la partie seculaire du couplage electron-noyau. Les particules de lithium metallique sont produites par irradiations aux neutrons thermiques de l'hydrure de lithium Li{sup 7}. Reproduction d'un article publie dans Physical Review Letters, vol. 3, no. 7, 1959, p. 338-340.

  19. Isomers chart; Table des isomeres

    Energy Technology Data Exchange (ETDEWEB)

    Dupont-Gautier, P; Chantelot, S; Moisson, N [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The nuclear isomers are nuclides offering the same mass number and the same atomic number, but different energy levels. In the following chart the zero energy ground states are omitted and the metastable isomers, i.e. of non-zero energy, known and of measurable lifetime, are listed. The lower limit of this lifetime was set here to 0.1 x 10{sup -6} s. The various isomers were classified in increasing lifetimes. (authors) [French] Les isomeres nucleaires sont des nucleides presentant le meme nombre de masse et le meme numero atomique, mais des niveaux energetiques differents. Dans la table suivante, on a neglige les etats fondamentaux d'energie nulle et on a recense les isomeres metastables, c'est-a-dire d'energie non nulle, connus et de periode mesurable. La limite inferieure de cette periode a ete fixee ici a 0,1 x 10{sup -6} s. Les differents isomeres ont ete classes par periodes croissantes. (auteurs)

  20. Isomers chart; Table des isomeres

    Energy Technology Data Exchange (ETDEWEB)

    Dupont-Gautier, P.; Chantelot, S.; Moisson, N. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The nuclear isomers are nuclides offering the same mass number and the same atomic number, but different energy levels. In the following chart the zero energy ground states are omitted and the metastable isomers, i.e. of non-zero energy, known and of measurable lifetime, are listed. The lower limit of this lifetime was set here to 0.1 x 10{sup -6} s. The various isomers were classified in increasing lifetimes. (authors) [French] Les isomeres nucleaires sont des nucleides presentant le meme nombre de masse et le meme numero atomique, mais des niveaux energetiques differents. Dans la table suivante, on a neglige les etats fondamentaux d'energie nulle et on a recense les isomeres metastables, c'est-a-dire d'energie non nulle, connus et de periode mesurable. La limite inferieure de cette periode a ete fixee ici a 0,1 x 10{sup -6} s. Les differents isomeres ont ete classes par periodes croissantes. (auteurs)

  1. Les mesures de métrologie pour le CLIC

    CERN Document Server

    Cherif, A

    2008-01-01

    Le projet CLIC est en tout point un défi technique majeur ; c?est le cas également pour la mesure dimensionnelle. Quels sont les équipements et les méthodes qui permettent de caractériser les pièces avec une incertitude de mesure aussi réduite que possible, vu les tolérances micrométriques imposées ? Afin de répondre à cette question, une veille technologique a été maintenue sur une longue période. Les acteurs relevants ont été contactés pour bénéficier d?une ouverture sur les dernières avancées dans le domaine. Différentes techniques ont été étudiées et comparées telles que la digitalisation, la tomographie X, la mesure tridimensionnelle. L'assemblage de haute précision des composants est aussi primordial. Sa mise en ?uvre sous un microscope optique ou à l'aide d'une machine tridimensionnelle est en cours d?étude. L'exposé traitera aussi de la mesure de rugosité, un domaine où nous disposons de moyens adaptés aux exigences spécifiques du projet.

  2. Elastic and inelastic scattering of 2 to 10 MeV protons by lithium isotopes; Diffusion elastique et inelastique des protons de 2 a 10 MeV par les isotopes du lithium

    Energy Technology Data Exchange (ETDEWEB)

    Laurat, M [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    A description is given of the experimental set-up which has been devised for carrying out spectrometric and absolute cross-section measurements on the reactions induced by protons accelerated in a 12 MeV Van de Graaff Tandem. The particles are detected by silicon junctions; the weight of the targets (about ten {mu}g/cm{sup 2}) is determined by the quartz method. The experimental equipment has been controlled by a study of proton scattering by lithium-6, and has made it possible to evaluate the elastic and inelastic scattering (1. level excitation) by lithium 7 of 2 to 9 MeV protons. The most probable spin and parity values for the six levels of {sup 8}Be between 19 and 25 MeV excitation energy have been determined from a knowledge of the observed structure. (author) [French] Nous decrivons le dispositif experimental mis au point pour effectuer les mesures de spectrometrie et de section efficace absolue pour les reactions induites par des protons acceleres par un Van de Graaff Tandem 12 MeV. Les particules sont detectees par des jonctions au silicium, le poids des cibles (de l'ordre d'une dizaine de {mu}g/cm{sup 2}), mesure par la methode du quartz. L'ensemble de l'appareillage a ete controle par l'etude de la diffusion des protons par le lithium 6, et nous a permis de preciser les diffusions elastiques et inelastiques (excitation du 1er niveau) des protons de 2 a 9 MeV par le lithium 7. La structure observee a permis de determiner les spin et parite les plus probables de six niveaux du {sup 8}Be entre 19 et 25 MeV d'energie d'excitation. (auteur)

  3. Elastic and inelastic scattering of 2 to 10 MeV protons by lithium isotopes; Diffusion elastique et inelastique des protons de 2 a 10 MeV par les isotopes du lithium

    Energy Technology Data Exchange (ETDEWEB)

    Laurat, M. [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    A description is given of the experimental set-up which has been devised for carrying out spectrometric and absolute cross-section measurements on the reactions induced by protons accelerated in a 12 MeV Van de Graaff Tandem. The particles are detected by silicon junctions; the weight of the targets (about ten {mu}g/cm{sup 2}) is determined by the quartz method. The experimental equipment has been controlled by a study of proton scattering by lithium-6, and has made it possible to evaluate the elastic and inelastic scattering (1. level excitation) by lithium 7 of 2 to 9 MeV protons. The most probable spin and parity values for the six levels of {sup 8}Be between 19 and 25 MeV excitation energy have been determined from a knowledge of the observed structure. (author) [French] Nous decrivons le dispositif experimental mis au point pour effectuer les mesures de spectrometrie et de section efficace absolue pour les reactions induites par des protons acceleres par un Van de Graaff Tandem 12 MeV. Les particules sont detectees par des jonctions au silicium, le poids des cibles (de l'ordre d'une dizaine de {mu}g/cm{sup 2}), mesure par la methode du quartz. L'ensemble de l'appareillage a ete controle par l'etude de la diffusion des protons par le lithium 6, et nous a permis de preciser les diffusions elastiques et inelastiques (excitation du 1er niveau) des protons de 2 a 9 MeV par le lithium 7. La structure observee a permis de determiner les spin et parite les plus probables de six niveaux du {sup 8}Be entre 19 et 25 MeV d'energie d'excitation. (auteur)

  4. Mesures de contraintes in-situ. Méthode de relaxation des carottes Measuring in-Situ Stresses. Relaxation Method with Core Samples

    Directory of Open Access Journals (Sweden)

    Perreau P.

    2006-11-01

    Full Text Available Dans cet article, on se propose de présenter les premiers résultats de l'étude de la méthode d'évaluation des contraintes par mesure de déformations différées d'une carotte après son extraction. Le travail correspondant a été réalisé dans le cadre du projet ARTEP Fracturation hydraulique . Les principes de cette méthode et les quelques éléments d'interprétation récemment publiés dans la littérature sont exposés dans un premier temps. Les résultats de deux campagnes de mesures sur deux puits de la SNEA-P (Soudron, novembre 1985 et Lanot, juillet 1986 sont ensuite présentés. Ces essais ont mis en évidence que les déformations différées d'une carotte dues au relachement des contraintes sont effectivement mesurables. Cependant, une interprétation quantitative de ces mesures nécessite une amélioration des conditions expérimentales (stabilisation thermique, stabilisation de l'état de saturation. This article describes the first results of research on a method of evaluating stresses by measuring the differred deformations of a core sample after it has been extracted. The corresponding research was done within the framework of an ARTEP project on Hydraulic Fracturing . The principles of this method and several interpretation aspects published recently in the literature are described in the first part. Then the results of two measurement campaigns using two SNEA-P wells (Soudron in November 1985 and Lanot in July 1986 are described. These tests revealed that the differed deformations of a core sample due to the relaxing of stresses can effectively be measured. However, a quantitative interpretation of these measurements requires an improvement to be made in the experimental conditions (thermal stabilization, stabilization of the state of saturation.

  5. Detection de la fin de la compaction des anodes par le son

    Science.gov (United States)

    Sanogo, Bazoumana

    L'objectif de ce projet etait de developper un outil de controle en temps reel du temps de compaction en se servant du son genere par le vibrocompacteur pendant le formage des anodes crues. Ainsi, une application a ete developpee pour l'analyse des sons enregistres. Des essais ont ete realises avec differents microphones pour une meilleure qualite des mesures et un a ete choisi pour la suite du projet. De meme, differents tests ont ete realises sur des anodes de laboratoire ainsi que des anodes a l'echelle industrielle afin de mettre en place une methode pour la detection du temps optimal necessaire au formage des anodes. Les travaux au laboratoire de carbone a l'Universite du Quebec a Chicoutimi (UQAC) ont consiste a l'enregistrement de son des anodes fabriquees sur place avec differentes configurations; et a la caracterisation de certaines anodes de l'usine. Les anodes fabriquees au laboratoire sont reparties en deux groupes. Le premier regroupe les anodes pour la validation de notre methode. Ce sont des anodes produites avec des temps de compaction differents. Le laboratoire de carbone a l'UQAC est unique et il est possible de produire des anodes avec les memes proprietes que celles des anodes industrielles. Par consequent, la validation initialement prevue a l'usine a ete effectuee avec les anodes de laboratoire. Le deuxieme groupe a servi a etudier les effets des matieres premieres sur le temps de compaction. Le type de coke et le type de brai ont constitue les differentes variations dans ce deuxieme groupe. Quant aux tests et mesures a l'usine, ils ont ete realises en trois campagnes de mesure. La premiere campagne en juin 2014 a servi a standardiser et a trouver le meilleur positionnement des appareils pour les mesures, a regler le logiciel et a faire les premieres mesures. Une deuxieme campagne en mai 2015 a fait l'objet d'enregistrement de son en classant les anodes selon differents temps de compaction. La troisieme et derniere campagne en decembre 2015 a

  6. Measurement of the thermal utilisation factor of the reactor G1; Mesure du facteur d'utilisation thermique du reacteur G1

    Energy Technology Data Exchange (ETDEWEB)

    Roullier, F; Schmitt, A P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The thermal utilisation factor of the lattice of the reactor G1 has been measured by applying the autoradiographic technique to thin detectors irradiated in the cell. The experimental apparatus is described, and the results compared with those obtained by calculation based on various formulae. The results of the study of the thermal flux distribution in a cell containing a thorium rod of the same diameter as the uranium rods in the lattice are also given. The precision of the measurements is discussed. Value found: f diameter 26 = 0.8949 {+-} 0,005. (author) [French] Le facteur d'utilisation thermique du reseau du reacteur G1 a ete mesure en appliquant la technique de l'autoradiographie a des detecteurs minces irradies dans la cellule. Les dispositifs experimentaux sont decrits et les resultats sont compares a ceux obtenus par le calcul a partir de diverses formules. Les resultats de l'etude de la distribution du flux thermique dans une cellule contenant une barre de thorium de meme diametre que les barres d'uranium du reseau sont egalement indiques. La precision des mesures est discutee. Valeur trouvee: f diametre 26 = 0,8949 {+-} 0,005. (author)

  7. Contribution to the study of once-forbidden {beta} transitions. Case of {sup 42}K and {sup 86}Rb; Contribution a l'etude des transitions {beta} une fois interdites. Cas de K{sup 42} et Rb{sup 86}

    Energy Technology Data Exchange (ETDEWEB)

    Andre, St [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-10-01

    An apparatus has been developed for studying the exact shape of the spectra of {beta} transitions which lead to an excited state of the final nucleus, using a Siegbahn-Slattis {beta} spectrometer. In particular the {beta} spectrum of the 2- {yields} 2+ transition of {sup 42}K has been measured; a considerable deviation has been found with respect to the statistical shape. The six elements of the nuclear matrices for this transition have been determined using this measurement and other results. It is shown that it cannot be explained by a pure f7/2 {yields} d3/2 transition. Furthermore the value obtained for the ratio of the matrix elements {integral}{alpha} and {integral}r is in excellent agreement with that predicted from the theory for the maintained vectorial current. (author) [French] On a realise et mis au point un appareillage permettant l'etude des formes precises des spectres {beta} des transitions aboutissant a un etat excite du noyau final sur un spectrometre {beta} Siegbahn-Slatis. On a mesure notamment le spectre {beta} de la transition 2- {yields} 2+ du K{sup 42}, mettant en evidence une deviation importante par rapport a la forme statistique. A partir de cette mesure et d'autres resultats, on a determine les six elements de matrice nucleaires de cette transition. On montre qu'elle ne peut pas etre expliquee par une transition f7/2 {yields} d3/2 pure. D'autre part, la valeur obtenue pour le rapport des elements de matrice {integral}{alpha} et {integral}r est en excellent accord avec celle qui est prevue a partir de la theorie du courant vectoriel conserve. (auteur)

  8. Measurement of the resonance escape probability; Mesure de l'absorption resonnante

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, J P; Bacher, P; Lheureux, L; Moreau, J; Schmitt, A P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The average cadmium ratio in natural uranium rods has been measured, using equal diameter natural uranium disks. These values correlated with independent measurements of the lattice buckling, enabled us to calculate values of the resonance escape probability for the G1 reactor with one or the other of two definitions. Measurements were performed on 26 mm and 32 mm rods, giving the following values for the resonance escape probability p: 0.8976 {+-} 0.005 and 0.912 {+-} 0.006 (d. 26 mm), 0.8627 {+-} 0.009 and 0.884 {+-} 0.01 (d. 32 mm). The influence of either definition on the lattice parameters is discussed, leading to values of the effective integral. Similar experiments have been performed with thorium rods. (author) [French] Nous avons mesure le rapport cadmium moyen dans des barres d'uranium a l'aide de disques d'uranium naturel de meme diametre que ces dernieres. Ces mesures nous ont permis, conjointement avec des mesures de Laplacien du reseau, de determiner deux facteurs antitrappes du reacteur G1 correspondant a deux definitions exposees. Les mesures ont ete faites sur deux diametres de barres 26 et 32 mm. Resultats: 0.8976 {+-} 0.005 and 0.912 {+-} 0.006 (d. 26 mm), 0.8627 {+-} 0.009 and 0.884 {+-} 0.01 (d. 32 mm). L'influence de ces deux definitions sur les divers parametres du reseau, est discutee. La determination de 'p' pour un diametre de barres d'uranium de 26 mm, et les mesures de variation de Laplacien, nous ont permis de calculer une valeur de l'integrale effective correspondant a chaque definition. Les mesures analogues faites sur des barres de thorium sont egalement indiquees. (auteur)

  9. L’octroi de crédits aux femmes entrepreneuses libanaises par les banquiers : le cas du dispositif Kafalat

    Directory of Open Access Journals (Sweden)

    Inaya Wahidi

    2016-03-01

    Full Text Available L’accès au crédit bancaire sans garantie est quasi impossible au Liban, d’où le dispositif Kafalat qui représente une solution face à cette difficulté. Selon la littérature, l’entrepreneuriat des femmes souffre de discrimination par rapport aux hommes quant à l’octroi de crédits bancaires. Notre objectif est d’essayer de voir dans quelle mesure cette situation existe au Liban. L’étude exploratoire conduite par entretiens semi-directifs auprès des banquiers exclusivement fournit les premiers éléments sur le profil de ces femmes entrepreneuses libanaises et sur la discrimination éventuelle qui pourrait exister du fait de leur sexe pour l’obtention de crédits bancaires. Les résultats semblent montrer que les banquiers ne font pas de distinction entre les entrepreneurs hommes ou femmes, même si les entrepreneuses ont peut-être moins d’informations concernant les garanties offertes par le dispositif Kafalat et sont souvent soutenues par leur mari qui accepte une hypothèque comme garantie du crédit demandé par leur femme ou qui passe par leur femme pour obtenir le crédit nécessaire au développement de leur propre entreprise.

  10. France's nuclear power programme; Le programme nucleaire francais

    Energy Technology Data Exchange (ETDEWEB)

    Cabanius, J [Electricite de France (EDF), 75 - Paris (France); Horowitz, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    -increasing importance, by using the country's resources of natural uranium, and later plutonium, to the best ends. (authors) [French] Les perspectives d'evolution de la consommation d'energie electrique francaise confirment l'aggravation du deficit des ressources energetiques metropolitaines. Les centrales nucleaires doivent permettre de diminuer ce deficit si un certain nombre d'incertitudes actuelles sont levees. Le premier programme presente par MM AILLERET et TARANGER a la Conference de Geneve en 1955 visait la mise en service pour 1965 de 850 MWe; il a ete consacre au developpement de la filiere uranium naturel - graphite - gaz et s'acheve avec la realisation d'EDF 3, premiere unite capable de 500 MWe engagee dans le monde. Avant de passer du stade des prototypes a celui des duplications, ELECTRICITE DE FRANCE a decide, en accord avec le COMMISSARIAT A L'ENERGIE ATOMIQUE, la realisation d'EDF 4 qui, en reprenant la partie reacteur d'EDF 3 ainsi que l'appareil de chargement et de dechargement, l'ensemble de controle et divers materiels, apporte une innovation importante en incorporant les echangeurs et les soufflantes a l'interieur du caisson en beton precontraint contenant le coeur. En meme temps, les etudes se poursuivent dans cette meme filiere et laissent entrevoir les possibilites d'utiliser un nouvel element combustible annulaire dont l'emploi ameliorerait notablement les performances d'EDF 5. Dans la filiere eau lourde, la realisation d'EL 4 a Brennilis par le COMMISSARIAT A L'ENERGIE ATOMIQUE et ELECTRICITE DE FRANCE se poursuit. Les etudes d'un reacteur de 500 MWe de cette filiere ont deja commence. Dans la filiere a eau pressurisee, la centrale de CHOOZ est realisee en association par ELECTRICITE DE FRANCE et les Producteurs Belges. Enfin, le COMMISSARIAT A L'ENERGIE ATOMIQUE poursuit a Cadarache la realisation du surgenerateur 'Rapsodie' et les etudes d'un reacteur de puissance plus important. Ainsi, les connaissances techniques et economiques acquises dans ces diverses

  11. The protection of labour against radioactivity in French uranium mines; Mesures prises dans les mines d'uranium de France pour assurer la protection du personnel contre les dangers de la radioactivite

    Energy Technology Data Exchange (ETDEWEB)

    Avril, R; Berger, Ch; Duhamel, F; Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The exploration and working of radioactive mineral deposits expose those concerned to both external and internal irradiation. Special protective measures are therefore required. In French mines, systematic monitoring and the observation of safety rules are applied effectively in combating irradiation risk. The preventive measures, however, considerably affect the manner of working and consequently boost the cost of the ore. (author) [French] Les travaux de recherches et d'exploitation executes dans les gisements de substances radioactives exposent le personnel des irradiations internes et externes necessitant des mesures speciales de protection. Dans les mines fran ises, un controle systematique des conditions de travail permet de mener de fa n efficace la lutte contre ces irradiations en respectant certaines normes de securite. Les mesures de prevention ont des repercussions sensibles sur la conduite de l'exploitation et, par suite, sur le prix de revient du minerai extrait. (auteur)

  12. Irradiation and development of the nuclear emulsions exposed to intense fluxes of thermal neutrons with {gamma} rays; Irradiation et developpement des emulsions nucleaires exposees a des flux intenses de neutrons thermiques, accompagnes de rayons {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, H; Bonnet, A; Cohen, J [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1952-07-01

    The thermal neutron fluxes provided by nuclear reactors permit the survey of relatively rare phenomenons, and dosage of very weak quantities of some elements. One of the most favorable detection technique are constituted by the use of the nuclear emulsions. one can mention: - the dosage of uranium by counting in the emulsion the number of traces due to fission fragments after irradiation. - The dosage of the lithium and the boron as trace amounts with the help of nuclear reactions (n, {alpha}) and thermal neutrons. - The research of reactions (n, {alpha}) or (n, p) of very weak cross section for middle or heavy elements. These different applications require however important neutrons fluxes. It had therefore obliged us to search for the most favorable irradiation and development of the emulsions conditions, to get the best visibility of the trajectories and decrease the phenomena of fog on the emulsion, which prevents any observation. (M.B.) [French] Les flux de neutrons thermiques fournis par les reacteurs nucleaires permettent l'etude de phenomenes relativement rares, et le dosage de tres faibles quantites de certains elements. Un des moyens de detection les plus favorables est constitue par l'utilisation des emulsions nucleaires. on peut citer: - le dosage de l'uranium par comptage dans l'emulsion du nombre de traces dues aux fragments de fission apres irradiation. - Le dosage du lithium et du bore a l'etat de traces a l'aide des reactions (n, {alpha}) sous l'action des neutrons thermiques. - La recherche de reactions (n,{alpha}) ou (n,p) de tres faible section efficace pour des elements moyens ou lourds. Ces differentes applications necessite cependant des flux de neutrons important. On a donc ete amene a rechercher les conditions les plus favorables d'irradiation et de developpement des emulsions, de maniere a obtenir la meilleure visibilite des trajectoires et diminuer les phenomenes de voile de l'emulsion, qui empeche toute observation. (M.B.)

  13. Irradiation and development of the nuclear emulsions exposed to intense fluxes of thermal neutrons with {gamma} rays; Irradiation et developpement des emulsions nucleaires exposees a des flux intenses de neutrons thermiques, accompagnes de rayons {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, H.; Bonnet, A.; Cohen, J. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1952-07-01

    The thermal neutron fluxes provided by nuclear reactors permit the survey of relatively rare phenomenons, and dosage of very weak quantities of some elements. One of the most favorable detection technique are constituted by the use of the nuclear emulsions. one can mention: - the dosage of uranium by counting in the emulsion the number of traces due to fission fragments after irradiation. - The dosage of the lithium and the boron as trace amounts with the help of nuclear reactions (n, {alpha}) and thermal neutrons. - The research of reactions (n, {alpha}) or (n, p) of very weak cross section for middle or heavy elements. These different applications require however important neutrons fluxes. It had therefore obliged us to search for the most favorable irradiation and development of the emulsions conditions, to get the best visibility of the trajectories and decrease the phenomena of fog on the emulsion, which prevents any observation. (M.B.) [French] Les flux de neutrons thermiques fournis par les reacteurs nucleaires permettent l'etude de phenomenes relativement rares, et le dosage de tres faibles quantites de certains elements. Un des moyens de detection les plus favorables est constitue par l'utilisation des emulsions nucleaires. on peut citer: - le dosage de l'uranium par comptage dans l'emulsion du nombre de traces dues aux fragments de fission apres irradiation. - Le dosage du lithium et du bore a l'etat de traces a l'aide des reactions (n, {alpha}) sous l'action des neutrons thermiques. - La recherche de reactions (n,{alpha}) ou (n,p) de tres faible section efficace pour des elements moyens ou lourds. Ces differentes applications necessite cependant des flux de neutrons important. On a donc ete amene a rechercher les conditions les plus favorables d'irradiation et de developpement des emulsions, de maniere a obtenir la meilleure visibilite des trajectoires et diminuer les phenomenes de voile de l'emulsion, qui

  14. Leçons d’analyse classique exposition d'un cours fait par Paul Koosis à l'Université McGill, Montréal

    CERN Document Server

    Poulin, Philippe

    2015-01-01

    Ce livre est basé sur un cours de deuxième cycle donné en 2005-2006 par M. Paul Koosis, professeur émérite à l'université McGill. Il traite de sujets soigneusement choisis par le professeur à l'intention de ceux qui, plutôt que de rechercher un catalogue exhaustif de résultats techniques et abstraits, veulent être initiés aux découvertes les plus essentielles et prolifiques de l'analyse classique du vingtième siècle. Analyse harmonique, quasi-analyticité, zéros des fonctions entières (dont une preuve inédite du théorème de Levinson-Cartwright), approximation pondérée, principe d'incertitude, mesures harmoniques…, les résultats saillants et géniaux de l'analyse classique sont présentés dans un style soigné, rigoureux et détaillé, préparant les étudiants à des études plus poussées ; et au service du lecteur qui, connaissant les bases de la théorie de la mesure et de l'analyse complexe, désire suivre le merveilleux développement de M. Koosis et accroître sa connaissance d...

  15. Rapid evaluation of the neutron dose following a criticality accident by measurement of {sup 24}Na activity; Evaluation rapide de la dose de neutrons a la suite d'un accident de criticite par mesure de l'activite de {sup 24}Na

    Energy Technology Data Exchange (ETDEWEB)

    Estournel, R [Centre de Production de Plutonium de Marcoule, Service de Protection contre les Rayonnements, 30 (France); Henry, Ph [Centre de Production de Plutonium de Marcoule, Section Medicale et Sociale, 30 (France); Beau, P; Ergas, A [Commissariat a l' Energie Atomique, Service d' Hygiene Atomique, Dept. de la Protection Sanitaire, Chusclan, (France)

    1966-07-01

    By external measurement of the gamma activity of {sup 24}Na induced in the human organs by a neutron flux during a criticality accident, it is possible to evaluate the personal dose received. Detectors designed for everyday use in health physics can be applied to these measurements, and this is described in the first part of the work. The response of a certain number of induced-activity detectors is presented. The induced activity-dose relationship is studied theoretically in the second part taking into account the neutron spectrum to which the individual has been subjected. The characteristic spectra of three possible types of accident have been used for deducing this relationship. The results obtained show that the method is sufficiently sensitive for present purposes. The accuracy of this method for calculating the dose received during an experiment is discussed. (authors) [French] La mesure par detection externe de l'activite gamma du sodium 24 induit dans l'organisme humain par un flux de neutrons lors d'un accident de criticite rend possible l'evaluation de la dose recue par un individu irradie. L'utilisation de detecteurs d'un emploi courant en radioprotection fait l'objet d'une experimentation qui constitue la premiere partie de cette etude. La reponse d'un certain nombre de detecteurs a une activite induite connue est presentee. La relation dose-activite induite, est etudiee, de maniere theorique, dans la seconde partie, correlativement au spectre des neutrons qui ont atteint l'individu irradie. Les spectres caracteristiques de trois types d'accidents possibles ont ete retenus pour l'etablissement de ces relations. Les resultats obtenus montrent que la methode satisfait avec une sensibilite suffisante au but recherche. La precision avec laquelle on peut ainsi calculer la dose recue au cours d'un accident de criticite est discutee. (auteurs)

  16. Results obtained in a spectrometry using junction detectors (1962); Resultats en spectrometrie {alpha} a l'aide de ''detecteurs jonction'' (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Beaumevieille, H; Fontenille, J; Lottgequeue, J P; Longequeue, N; Rabour, C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    Junction detectors have been used for studying {alpha} spectra obtained by nuclear reactions (p, {alpha}), the protons being produced by an electrostatic accelerator (E{sub p} varying from 100 to 600 keV). Difficulties have been encountered arising from parasitic noise from the accelerator and from the distance (60 metres) between detectors and electronic equipment. Resolution of the counter has been found to be 0.6 per cent with {alpha} from {sup 210}Po and 1.2 pour cent with {alpha} (5.8 MeV) from the reaction {sup 11}B (p, {alpha}{sub 0}). (authors) [French] Des detecteurs a jonction ont ete utilises pour l'etude de spectres {alpha} obtenus par reactions nucleaires (p, {alpha}), les protons etant acceleres par un accelerateur electrostatique (E{sub p} variant de 100 a 600 keV). Des difficultes ont ete recontrees dues aux parasites provenant de l'accelerateur et a la distance des cables (60 metres) entre detecteurs et appareils de mesure. Le pouvoir de resolution de l'ensemble a ete de 0, 6 pour cent avec les {alpha} du {sup 210}Po et de 1,2 pour cent avec les {alpha} (5,8 MeV) de la reaction {sup 11}B (p, {alpha}{sub 0}). (auteurs)

  17. Nuclear explosion and internal contamination; Explosion nucleaire et contamination interne

    Energy Technology Data Exchange (ETDEWEB)

    Aeberhardt, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    By the study of the conditions of internal contamination due to the radioactive mixture produced by a nuclear explosion, the parts played by the relative weights of the different elements and the mode of expression of the doses are considered. Only the knowledge of the weight composition of the contamination mixture and of its evolution as a function of time can provide the required basis for the study of its metabolism in the organism. The curves which give the composition of the fission product mixture - in number of nuclei - - as a function of time - have been established. These curves are applied to some practical examples, particularly relative to the nature of contamination, radiotoxicity of some elements and assessment of hazards. (author) [French] Etudiant les modalites de la contamination interne par les elements radioactifs apparus lors d'une explosion nucleaire, le role de la 'masse' et le mode d'expression des doses sont envisages. La connaissance de la composition en 'masse' du melange contaminant et de son evolution en fonction du temps peut seule apporter les bases necessaires a l'etude de son comportement dans l'organisme. Les courbes donnant la composition du melange de produits de fission - en nombre de noyaux - - en fonction du temps - ont ete etablies. Quelques applications pratiques, relatives en particulier a la nature de la contamination, a la radiotoxicite de certains elements et a l'evaluation de risque, sont envisagees a titre d'exemple. (auteur)

  18. Contribution to the determination of Sb-Ag-Cu-Ga-Mo-Zn using 14 MeV neutron activation; Contribution au dosage de Sb-Ag-Cu-Ga-Mo-Zn par activation aux neutrons de 14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Crambes, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1966-04-01

    By using, 14 MeV, neutron irradiation it is possible to extend the field of application of neutron radio-activation analysis, in particular to the case of light elements. For, many other elements it can replace in-pile irradiation thereby making it possible, thanks to portable 14 MeV neutron generators, to carry out radio-activation analyses away from nuclear-research c e n t r e s. With a view to applying this analytical technique to routine work, we have developed some rapid chemical separation methods in order to make possible the determination of several elements which after exposure to fast neutrons, produce {beta} emitting nuclides which cannot be differentiated by a simple instrumental study, the emitted radiation being of the same type and of similar half-life the two cases. (author) [French] L'irradiation au moyen de neutrons de 14 MeV permet d'etendre le domaine d'application de l'analyse par radioactivation neutronique, en particulier aux elements legers. Cependant pour de nombreux autres elements elle peut remplacer l'irradiation en reacteur nucleaire permettant ainsi grace aux ensembles portables producteurs de neutrons de 14 MeV, l'extension de l'analyse par radioactivation a l'exterieur des centres d'etudes nucleaires. Dans le but d'appliquer cette methode d'analyse a des travaux de routine, nous avons mis au point des separations chimiques rapides, afin de permettre le dosage de quelques elements qui par irradiation aux neutrons rapides, engendrent des nucleides emetteurs {beta} qu'une simple etude instrumentale ne peut differencier en raison de l'identite de leur rayonnement et de leurs periodes radioactives trop proches. (auteur)

  19. SCPRI Emergency Kit for Use in the Event of a Nuclear Accident; Le Dispositif d'Intervention Rapide du SCPRI en Cas d'Accident Nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Ervet, P.; Moroni, J. P.; Pellerin, P. [Service Central de Protection Contre les Rayonnements Ionisants, Ministere des Affaires Sociales, Le Vesinet (France)

    1969-10-15

    In the event of a nuclear accident necessitating implementation of the ORSEC radiation protection plan, the Service central de protection contre les rayonnements ionisants (Central Service for Protection against Ionizing Radiations), in conjunction with the Service national de la protection civile (National Civil Defence Service), has adopted the necessary measures for rapid evaluation of possible contamination as promptly as possible. With this aim in mind the Service has prepared emergency kits, which are permanently stored at airfields in the Paris region; these can be carried by aircraft together with two engineers from the Service, thereby enabling them to reach the site of the incident with the specialized equipment in a few hours at most. This paper describes the monitoring and sampling equipment as well as the conditions under which the kit is carried and used (it operates independently by having a built-in generating unit). It is basically designed to permit an initial assessment of the situation, to furnish local authorities with data on which to base decisions for the safety of the population, and to determine any additional measures that need to be adopted. (author) [French] Dans le cas d'un accident nucleaire impliquant la mise en application du plan ORSEC radiologique, en liaison avec le Service national de la protection civile, le Service central de protection contre les rayonnements ionisants a pris les dispositions necessaires pour faire une evaluation rapide, aussi preooce que possible, des contaminations eventuelles. Dans ce but, il a realise des cantines d'intervention qui sont deposees en permanence sur les aerodromes de la region parisienne, et peuvent etre embarquees par avion avec deux ingenieurs du service qui peuvent etre ainsi sur les lieux de l'incident, avec un materiel specialise, dans un delai qui n'excede pas quelques heures. Le memoire decrit le materiel de mesure et de prelevement, ainsi que les conditions de transport et d

  20. Determination by neutron activation of the uranium-235 concentration in uranium oxides; Determination par activation neutronique de la concentration d'uranium-235 dans des oxydes d'urane

    Energy Technology Data Exchange (ETDEWEB)

    May, S; Leveque, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Classical methods of measuring isotopic abundance have the disadvantage of being long and of requiring chemical separation. A non-destructive method of measuring the uranium-235 content is described. It is based on an overall measurement of the short lived fission product activity formed during a 15 s neutron irradiation. The precision is of the order {+-} 1.5 per cent for 20 per cent enriched samples. The error due to the contribution from fast fission is discussed in detail. (author) [French] Les methodes classiques de mesure de l'abondance isotopique presentent le gros inconvenient d'etre longues et de necessiter des separations chimiques. Nous exposons une methode non destructive de mesure de la concentration d'uranium-235. Elle est basee sur la mesure globale de l'activite des produits de fission de courte periode formes par une irradiation neutronique de 15 s de l'echantillon. La precision est de l'ordre de {+-} 1,5 pour cent pour des echantillons enrichis jusqu'a 20 pour cent. L'erreur a la contribution de la fission rapide est discutee en detail. (auteur)

  1. A Nitrogen-16 Power Channel in the Melusine Cooling Circuit; Chaine de puissance azote 16 sur le circuit de refrigeration de melusine

    Energy Technology Data Exchange (ETDEWEB)

    Tiberghien, R [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires, 38 - Grenoble (France)

    1962-07-01

    A power channel, which is to be used on Melusine, the 2 MW pool-type reactor built at Grenoble Nuclear Center, is described. It will be used for measuring of {sup 16}N activity of water after passage through the reactor core. The experimental system as well as the measuring instruments are described. Solutions to problems likely to arise are given. The experimental results show that this power measurement is free from neutron flux local deformations, from control rods position, and from experiments. The power indicated is to {+-}2% the same as the thermodynamic power. Since May 1962, this power channel is used as a reference for the operation of the reactor. It is also provided for on the Siloe 10 MW reactor. (author) [French] L'objet de ce rapport est la description d'une nouvelle chaine de puissance pour la pile piscine 'Melusine' de 2 MW du Centre d'etudes Nucleaires de Grenoble. Il s'agit de la mesure de l'activite en azote 16 de l'eau apres son passage dans le coeur du reacteur. Le dispositif experimental ainsi que les appareils de mesure y sont decrits. Les reponses aux differents problemes poses sont donnees. Les resultats experimentaux montrent que cette mesure de puissance est independante des deformations locales de flux de neutrons, de la position des barres de controle et des manipulations. La puissance indiquee par cette chaine est a 2 % pres identique a la puissance thermodynamique. Depuis mai 1962, elle est utilisee comme reference pour le pilotage de la pile. Elle est aussi prevue sur la pile 'Siloe' de 10 MW. (auteur)

  2. Siloette, Siloe mock-up; Siloette, modele nucleaire de siloe

    Energy Technology Data Exchange (ETDEWEB)

    Delcroix, V; Jeanne, G; Mitault, G; Schulhof, P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    Siloette is the Siloe mock-up. The main installations are described: various tanks, building, auxiliaries, control systems... Precis ions are given about precautions taken for using spent fuel elements. (authors) [French] Siloette est le modele nucleaire de SILOE. On decrit ses diverses installations: bassins, batiments, auxiliaires, controle... Des precisions sont donnees sur les precautions prises pour y utiliser des elements uses. (auteurs)

  3. Determination of the sanguine iodine content by activation analysis (1962); Determination de l'iode sanguin par analyse d'activation (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Kellershohn, C; Comar, D; Le Poec, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Two methods of measuring the iodine content of the blood by activation analysis after 30 min irradiation in a flux of 6.10{sup 12} n/cm{sup 2}.s are described. One method includes a chemical separation of iodine before irradiation. The radioactivity of this specimen is determined on the basis of the amplitude of the iodine 128 photoelectric peak measured by {gamma}-spectrometry. The sensitivity of this method is about 10{sup -8} g. The other includes chemical separation after irradiation, and radioactivity is subsequently measured with a Geiger-Muller counter. The sensitivity of this second method is about 10{sup -10} g, sufficient for determination of the plasmatic mineral content. The advantages of activation analysis over the conventional method based on colorimetric measurement of the catalytic action of iodine in the oxidation of arsenious anhydride with ceric sulphate are discussed. Initial results obtained with this new form of analysis are detailed as are also the possibilities of measuring plasmatic proteic iodine by scintillation spectrometry without prior chemical separation. (authors) [French] Deux methodes de dosage de l'iode sanguin par analyse d'activation apres irradiation de 30 minutes a 6.10{sup 12} n/cm{sup 2} s sont decrites. L'une comprend une separation chimique de l'iode avant l'irradiation et la mesure de la radioactivite est effectuee a partir de l'amplitude du pic photo-electrique de l'iode 128 obtenu par spectrometrie-{gamma}. Sa sensibilite est de l'ordre de 10{sup -8} g. L'autre comprend une separation chimique de l'iode apres l'irradiation et la radioactivite de l'iode-128 est mesuree par comptage-{beta} avec un compteur Geiger. Sa sensibilite est de l'ordre de 10{sup -10} g, permettant d'envisager le dosage de l'iode mineral plasmatique. Les avantages de l'analyse d'activation sur la methode classique, basee sur la mesure colorimetrique de l'action catalytique de l'iode dans l'oxydation de l'anhydride arsenieux par le sulfate cerique

  4. Development of a technique of preparation of uranium screens for soft X Ray spectrography (1960); Mise au point d'une technique de preparation d'ecrans d'uranium pour la spectrographie de rayons X mous (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bersuder, L de [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    The present work concerns the preparation of thin layers of pure uranium (thickness 100 to 1000 Angstrom) by thermal evaporation under vacuum. The protection of uranium against oxidation is obtained by using aluminium deposits under and above the uranium layer. The purity of the layers obtained is checked by electron diffraction and the necessary conditions to avoid oxidation and alloy formation during the formation of deposit are studied. Three methods for measuring the thickness are examined: by {alpha} particle counting, by weighing the condensed mass and by weighing the evaporated mass. The method using {alpha} particle counting turned to be the most accurate for low thickness layers. (author) [French] Le present travail concerne la preparation de couches minces d'uranium pur (epaisseurs de 100 a 1000 Angstrom) par evaporation thermique sous vide. La protection de l'uranium contre l'oxydation par l'air est obtenue grace a des couches d'aluminium deposees sous vide sous et sur la couche d'uranium. La purete des couches obtenues est verifiee par diffraction d'electrons et les conditions necessaires pour eviter l'oxydation et la formation d'alliages lors du depot sont etudiees. Trois methodes de mesure des epaisseurs sont examinees, mesure par comptage de particules {alpha}, mesure par pesee de la masse condensee et mesure par pesee de la masse evaporee. La mesure par comptage de particules {alpha} s'avere etre la plus precise pour les couches de faibles epaisseurs. (auteur)

  5. The use radioactive tracers in the study of solid transport in water streams; Emploi de traceurs radioactifs pour l'etude du transport solide dans les cours d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Jaffry, P; Heuzel, M [Laboratoire National d' Hydraulique de Chatou, 78 (France)

    1960-07-01

    riviere, la premiere a ete consacree a l'etude du charriage des galets dans le Rhone, l'autre a l'etude des transports de sables dans le Niger. Cette derniere experience a ete doublee d'experiences identiques, effectuees sur le modele reduit du fleuve Niger exploite par le Laboratoire de Chatou: dans ces experiences, on utilise le rayonnement du {sup 56}Mn et du {sup 24}Na obtenu par activation directe du noyau d'abricot concasse representant sur le modele reduit le sediment naturel du lit du Niger. Les efforts conjugues du Laboratoire de Chatou et du Centre d'Etudes Nucleaires de Saclay portent actuellement sur l'application des traceurs radioactifs aux etudes sur modeles reduits, dans le double but: a) de disposer d'un meme moyen d'investigation en nature et sur modele reduit pour controler la fidelite du modele, dans la phase des essais d'etalonnage; b) de profiter des facilites d'observation et mesures directes offertes par les modeles reduits pour etudier les possibilites d'amelioration de la methode des traceurs, en particulier en ce qui concerne l'obtention de renseignements quantitatifs. (auteur)

  6. Theoretical and experimental study of a calorimetric technique for measuring energy deposition in materials caused by complex pile irradiation; Etude theorique et experimentale d'une technique calorimetrique de mesure des depots d'energie dans les materiaux dus au rayonnement complexe de pile

    Energy Technology Data Exchange (ETDEWEB)

    Mas, P; Sciers, P; Droulers, Y [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires, 38 - Grenoble (France)

    1962-07-01

    Calorimetric methods may be used to measure gamma fluxes greater than 10{sup 6} r/h near the cores of swimming pool reactors. The theory, design, and properties of isothermal calorimeters are discussed, and experimental results obtained with two types are presented. Measurement of energy deposition in materials and the long term integration of energy depositions are other uses of these devices. Results of measurements on heat deposition in steel and water are given. Fluxes were also measured. (authors) [French] Une premiere partie traite de la theorie des calorimetres isothermes mis en oeuvre au C.K.N. Grenoble. La puissance deposee dans le calorimetre par les flux de rayonnement echauffe celui-ci. L'echauffement est mesure a l'aide d'un thermocouple. On montre que l'on a ainsi une mesure absolue de cette puissance. Une deuxieme partie traite de l'etude experimentale de: deux types d'appareils utilises: leur construction, les resultats experimentaux, leurs utilisations. Trois de celles-ci sont particulierement interessantes: - la mesure des hauts flux gamma, - la mesure du depot d'energie dans les materiaux, - l'integration pendant une longue duree des depots d'energie (un modele de calorimetre a fonctionne a ce jour 2 500 heures et a integre 9 x 10 puissance 10 rads gamma et 6 x 10 puissance 18 neutrons rapides). La troisieme partie est consacree a l'etude des qualites de l'appareil: robustesse, fidelite, precision, sensibilite, gamme de mesure. Enfin dans la derniere partie sont decrites deux applications de la methode calorimetrique a la mesure du depot d'energie dans un acier special et dans l'eau. (auteurs)

  7. Contribution to the study of aerosol photometers, application to the measurement of filter efficiency; Contribution a l'etude des photometres a aerosols, application a la mesure de l'efficacite des filtres

    Energy Technology Data Exchange (ETDEWEB)

    Billard, F; Hadelaine, G

    1968-01-01

    The measurement of the quantity of diffused light by particulates in suspension in a gas allows to determine the concentration and the size of an aerosol. The aim of this work is to check the answer of the usual photometer in the laboratories, the Phoenix-Sinclair and the Royco-230. The minimum diameter of the particulates detected by these photometers is about 0.3 microns. [French] La mesure de la quantite de lumiere diffusee par des particules en suspension dans un gaz permet de determiner la concentration et les dimensions d'un aerosol. Le but de ce travail est de verifier la reponse du photometres d'usage courant dans les laboratoires, le Phoenix-Sinclair et le Royco-230. Le diametre minimum des particules detectees par ces photometres est d'environ 0, 3 microns. (auteurs)

  8. Associative memories in nuclear physics; Les memoires associatives en physique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Blanca, E; Carriere, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Experiments in nuclear physics involve the use of large size 'memories'. After showing the difficulties arising from the use of such memories, the authors give the principles of the various programming methods which make it possible to operate the memories associatively thus benefiting from a reduction in size and better operational conditions. They attempt to estimate the shape and dimensions of an associative memory with cable connections which could be designed specially for nuclear research, contrary to those actually in service. (authors) [French] Les experiences de physique nucleaire necessitent l'emploi de 'memoires' de grandes dimensions. Apres avoir montre les inconvenients que presente l'utilisation de telles memoires, les auteurs exposent les principes des diverses methodes de programmation qui permettent d'assurer un fonctionnement des memoires sur le mode associatif donc une reduction de leurs dimensions et un meilleur usage. Ils tentent d'evaluer le format d'une memoire associative cablee qui, contrairement a celles qui existent actuellement, serait prevue specialement pour l'experimentation nucleaire. (auteurs)

  9. Use of 14 MeV neutrons in activation analysis. Experiments carried out at the Grenoble nuclear research Centre (1963); Utilisation de neutrons de 14 MeV en analyse par activation. Experience realisee au Centre d'etudes nucleaires de Grenoble (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Auboin, G; Guazzoni, P; Laverlochere, J [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-01

    The use of 14 MeV neutron irradiation makes it possible to extend the field of application of activation analysis to elements which cannot be activated in nuclear reactors (oxygen, boron, for example) or else to consider the possibility of 'portable' measurement units for routine analyses. With this aim, tests have been carried out for studying the sensitivity and interferences in the case of the dosing of oxygen in eleven different matrices using 150 and 300 kV SAMES accelerators producing 14 MeV neutrons by the reaction {sup 3}H (d, n) {sup 4}He. The sensitivity of the dosage methods for six writer elements has also been studied. The results obtained show that, for a neutron flux of 10{sup 10} n/4{pi}, the sensitivities vary from 100 {mu}g and 1 mg for oxygen in nine matrices (Be, Ta, Nb, Ti, Zr, Fe, Al, Sb, Si) and that it is possible to dose the six elements F, B, Y, Si, N, Al with sensitivities of between 1 an 1000 micrograms. (authors) [French] L'irradiation au moyen de neutrons de 14 MeV permet d'etendre le domaine d'application de l'analyse par activation a des elements non activables en reacteur nucleaire (oxygene, bore, par exemple) ou encore d'envisager des unites de dosage ''portables'' pour des analyses de routine. Dans ce but, des essais ont ete effectues pour etudier les sensibilites et les interferences dans le cas du dosage de l'oxygene dans onze matrices differentes, au moyen d'accelerateurs SAMES 150 et 300 kV. produisant les neutrons de 14 MeV par la reaction {sup 3}H (d, n) {sup 4}He. Des sensibilites de dosage ont egalement ete etudiees pour six autres elements. Les resultats obtenus montrent que, pour un flux de neutrons de 10{sup 10} n /4{pi}, les sensibilites varient entre 100 {mu}g et 1 mg, pour l'oxygene dans neuf matrices (Be, Ta, Nb, Ti, Zr, Fe, Al, Sb, Si) et qu'il est possible de doser les six elements F, B, Y, Si, N, Al avec des sensibilites se situant entre 1 et 1000 microgrammes. (auteurs)

  10. The study of neutron propagation in natural uranium; Etude de la propagation des neutrons dans l'uranium naturel

    Energy Technology Data Exchange (ETDEWEB)

    Campan, J L; Clauzon, P P; Kirchner, B; Ribon, P; Zaleski, C P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Fast exponential experiment. Experimental facilities are described; the experimental results obtained with the block of natural uranium are then presented. Detectors used were fission chambers, activation detectors and nuclear emulsions. One tries to explain the results, which are, then compared with theoretical values obtained by calculations based on diffusion theory. Measured spectrum (pseudo equilibrium) may be characterised by the following values: diffusion length: 95,25 {+-} 0,5; {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 238} : 230 {+-} 10, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Np{sub 237} : 14 {+-} 0.5, {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 233} : 0.67 {+-} 0.03, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Pu{sub 239} : 0.90 {+-} 0.05, {sigma}{sub f}U{sub 235}/{sigma}(ny) In : 230 {+-}10. (author) [French] Experience exponentielle rapide. Apres une description du dispositif experimental, on presente des resultats de mesures effectuees dans un massif d'uranium naturel. Les detecteurs utilises sont des chambres a fission, des detecteurs d'activation et des emulsions nucleaires. Une interpretation des resultats est donnee; ceux-ci sont compares a des valeurs theoriques obtenues par des calculs utilisant la theorie de la diffusion. Le spectre mesure (pseudo equilibre) peut etre caracterise par les valeurs suivantes: Longueur de diffusion: 95,25 {+-} 0,5; {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 238} : 230 {+-} 10, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Np{sub 237} : 14 {+-} 0.5, {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 233} : 0.67 {+-} 0.03, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Pu{sub 239} : 0.90 {+-} 0.05, {sigma}{sub f}U{sub 235}/{sigma}(ny) In : 230 {+-}10. (auteur)

  11. On Absolute Measurements of {beta}-Emitting Radionuclides; Mesures absolues d'emetteurs {beta}; Absolyutnye izmereniya {beta} izluchayushchikh radioizotopov; Sobre la medicion absoluta de los emisores {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, A M [Centro de Estudos de Fisica, Comisao de Estudos de Energia Nuclear, Instituto Portugues de Oncologia, Lisboa (Portugal)

    1960-06-15

    4 {pi} GM detectors are described and some of their characteristics presented. The absence of spurious pulses is shown by the measurement of the rate of arrival of intervals between pulses. Some problems related to the foil absorption and source absorption are considered using Sr{sup 90} and Y{sup 90}. Aiming at correcting the counting losses in the foil and in a certain extent also the source absorption an experimental method which uses paired sources is presented. The preparation of standards of Bi{sup 210} (RaE) is described. A note is presented on the problem of foil absorption losses in scintillation absolute counting. (author) [French] Le memoire decrit des detecteurs 4 {pi} GM et donne certaines de leurs caracteristiques. L'absence d'impulsions parasites est indiquee par la mesure de la cadence d'arrivee des impulsions. L'auteur examine plusieurs problemes que posent l'absorption par la source et l'absorption par la feuille lorsqu'on utilise du Sr{sup 90} et du Y{sup 90}. Il expose une methode experimentale dans laquelle il emploie des sources deux a deux en vue de corriger les pertes au comptage dans la feuille et aussi, dans une certaine mesure, l'absorption par la source. L'auteur decrit la preparation d'etalon de Bi{sup 210} (RaE). Il ajoute une note sur le probleme des pertes par absorption dans la feuille dans le comptage absolu par scintillations. (author) [Spanish] Se describen los detectores Geiger-Mueller 4 {pi} y algunas de sus caracteristicas. La ausencia de impulsos parasitos se comprueba midiendo el ritmo a que se suceden los intervalos entre los impulsos. Con ayuda de Sr{sup 90} y Y{sup 90}, se estudian algunos de los problemas de autoabsorcion y de la absorcion por las hojas. Con el propositio de corregir la disminucion del numero de impulsos debido a la absorcion en las hojas y, hasta cierto punto, a la autoabsorcion, el autor propone un metodo experimental que emplea fuentes pareadas. Asimismo, describe la preparacion de patrones de Ba

  12. Contribution to the experimental survey of the nuclear isomerism. Application of the deferred coincidences method to research and to the survey of metastable states of short period; Contribution a l'etude experimentale de l'isomerie nucleaire. Application de la methode des coincidences differees a la recherche et a l'etude d'etats metastables de periode courte

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-06-15

    transitions qu'ils subissent, lorsqu'elles donnent naissance a des especes nucleaires mieux connues: parmi ces transitions figurent les transitions isomeriques. Le but de ce travail est l'etude des transitions isomeriques a partir d'etats metastables de periode courte, comprise dans le domaine de la microseconde a quelques millisecondes. La methode des coincidences differees a ete mise au point et appliquee dans ce but en utilisant les avantages des selecteurs a plusieurs canaux, sous deux aspects principaux ou l'appareil a plusieurs canaux etait soit un selecteur de temps, soit un selecteur d'amplitudes. Cette methode a servi a etudier le fonctionnement de compteurs Geiger-Muller et a mesurer avec precision la periode de {sup 181}Ta{sup *} dans des conditions experimentales variees. La valeur adoptee est 17,2 {+-} 0,2 {mu}s. Ce travail a aussi trouve une application pratique immediate a la mise en evidence de quantites tres faibles de hafnium dans le zirconium, dont il constitue une impurete tenace et difficile a analyser par les moyens ordinaires. (M.B.)

  13. Isotope analysis by emission spectroscopy; Analyse isotopique par spectroscopie d'emission

    Energy Technology Data Exchange (ETDEWEB)

    Artaud, J; Gerstenkorn, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Blaise, J [Centre National de la Recherche Scientifique (CNRS), Lab. Aime Cotton, 92 - Meudon-Bellevue (France)

    1959-07-01

    melange d'isotopes d'un meme element sont complexes. Chaque raie spectrale est en realite la resultante de plusieurs raies correspondant respectivement a chacun des isotopes. Ces composantes isotopiques sont proches les unes des autres et leur separation est realisee au moyen de l'etalon FABRY-PEROT, et l'appareil permettant la mesure des abondances est le spectrometre FABRY-PEROT photoelectrique, imagine en 1948 par MM. JACQUINOT et DUFOUR. Cette methode a ete utilisee pour effectuer des mesures d'abondance dans le cas de l'helium, du lithium, du plomb et de l'uranium. Dans le cas du lithium, la raie d'analyse utilisee depend de la composition du melange isotopique etudie. C'est la raie bleue de lithium {lambda} = 4603 angstrom pour des melanges contenant de 7 a 93 pour cent de l'un des isotopes du lithium. Dans les autres cas, la raie rouge {lambda} = 6707 angstrom est preferable, mais elle ne permet de faire aisement que des mesures relatives. L'helium n'offre pas de difficultes particulieres et la raie d'analyse choisie est la raie {lambda} = 6678 angstrom. La raie {lambda}-5201 angstrom du plomb offre la possibilite de doser les quatre isotopes de plomb, malgre l'existence de la structure hyperfine de 207 Pb. Pour l'uranium, en utilisant la raie {lambda} = 5027 angstrom, cette methode permet de doser des melanges isotopiques dont la teneur en {sup 235}U peut descendre jusqu'a 0,1 pour cent. La precision relative est de l'ordre de 2 pour cent pour des teneurs en {sup 235}U superieures a 1 pour cent. Pour des teneurs plus faibles cette raie {lambda} = 5027 angstrom permettra des mesures relatives de meilleure precision, en utilisant des melanges prealablement doses. (auteur)

  14. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  15. On some uses of the recording op fission fragments occurring in insulators; Sur quelques utilisations de l'enregistrement des fragments de fission dans les isolants

    Energy Technology Data Exchange (ETDEWEB)

    Mory, J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-07-01

    thermiques: on peut mesurer des flux integres s'etendant de 10{sup 3} a 10{sup 21} n/cm{sup 2}, suivant la methode utilisee; - dosimetrie de neutrons rapides: en utilisant des sources de fragments de fission a seuil, on peut facilement mesurer des doses d'interet biologique de l'ordre du rem; - dosage d'impuretes fissiles en tres faible concentration: on peut determiner des concentrations atomiques de l'ordre de 10{sup 9}, limite jamais atteinte par les procedes usuels; - etude des elements fissiles contenus dans les poussieres atmospheriques. On donne ensuite brievement les resultats d'un essai d'automatisation du comptage des traces par mesure de la resistivite electrique de la membrane irradiee. On expose enfin les avantages et les inconvenients de ces detecteurs solides, notamment par rapport aux emulsions nucleaires dont les utilisations sont a peu pres identiques. (auteur)

  16. Measurement of the absolute values of cross-sections in neutron photoproduction (1962); Mesure de sections efficaces de photoproduction de neutrons en valeur absolue (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Schuhl, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    The absolute values of photoneutrons production cross-sections for the case of intermediate and heavy nuclei (lanthanium, cerium, tantalum, gold, lead and bismuth) are determined with an error of 15 per cent. The results obtained agree with theories in which the giant resonance is explained by the collective motion of the protons against the neutrons. The effect of the nuclear deformation on the shape of the giant resonance is seen in the case of Ta{sup 181}, it will be possible to determine the quadrupole momenta of deformed nuclei with a good accuracy when we shall increase the statistics of measurements. (author) [French] Les sections efficaces de production de photoneutrons par divers noyaux moyens et lourds (lanthane, cerium, tantale, or, plomb et bismuth) sont determinees en valeur absolue avec une erreur relative de 15 pour cent. Les resultats obtenus s'accordent avec les theories qui interpretent la resonance geante par un mouvement collectif des protons par rapport aux neutrons. L'influence de la deformation du noyau sur la forme de la resonance geante est soulignee dans le cas de {sup 181}Ta pour lequel elle se decompose en deux pics. Une amelioration de la statistique des mesures permettra de determiner les moments quadrupolaires des noyaux deformes avec une meilleure precision. (auteur)

  17. Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie

    Energy Technology Data Exchange (ETDEWEB)

    Bocquet, M; Micaud, G

    1962-07-01

    An apparatus was developed for measuring the thermal conductivity coefficient K of irradiated or non-irradiated graphite. The measurement of K at around room temperature with an accuracy of about 6% is possible. The study specimen is placed in a vacuum between a hot and a cold source which create a temperature gradient {delta}{theta}/ {delta}x in the steady state. The amount of heat transferred, Q, is deduced from the electrical power dissipated at the hot source, after allowing for heat losses. The thermal conductivity coefficient is defined as: K = Q/S. {delta}x/{delta}{theta}, S being the cross section of the sample. Systematic studies have made it possible to determine the mean values of the thermal conductivity. (authors) [French] Un appareil de mesure du coefficient de conductibilite thermique K du graphite irradie ou non irradie a ete realise. Utilisant le principe du transfert de chaleur, il permet de mesurer K au voisinage de la temperature ambiante avec une precision de 6 pour cent environ. L'echantillon de graphite etudie est place sous vide entre une source chaude et une source froide qui creent en regime permanent un gradient de temperature {delta}{theta}/{delta}x La quantite de chaleur transferee Q est deduite de la puissance electrique dissipee dans la source chaude en deduisant les pertes thermiques. Le coefficient de conductibilite thermique est defini par: K = Q/S. {delta}x/{delta}{theta} S designant la section de l'echantillon. Des etudes systematiques ont permis de determiner pour differents graphites non irradies les valeurs moyennes des coefficients de conductibilite thermique. Ces etudes ont mis en evidence pour un type de graphite donne, l'influence de la densite apparente sur le coefficient de conductibilite thermique. A partir de mesures effectuees sur des echantillons de graphite irradies preleves par carottage dans les empilements des reacteurs a moderateur de graphite les variations du rapport K0/Ki en fonction de la dose et de la

  18. Contribution to the study of nuclear fuel materials with a metallic uranium base; Contribution a l'etude des materiaux combustibles nucleaires a base d'uranium metallique

    Energy Technology Data Exchange (ETDEWEB)

    Englander, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-11-15

    In a power reactor destined to supply industrially recoverable thermal energy, the most economical source of heat still consists of natural metallic uranium. However, the nuclear fuel material, most often employed in the form of rods of 20 to 40 mm diameter, is subjected to a series of stresses which lead to irreversible distortions usually incompatible with the substructure of the reactor. As a result the fuel material must possess at the outset a certain number of qualities which must be determined. Investigations have therefore been carried out, first on the technological characters peculiar to each of the three allotropic phases of pure uranium metal, and on their interactions on the stabilisation of the material which consists of either cast uranium or uranium pile-treated in the {gamma} phase. (author) [French] Dans un reacteur de puissance destine a fournir de l'energie thermique industriellement recuperable, la source de chaleur la plus economique reste constituee par de l'uranium metallique naturel. Or, le materiau combustible nucleaire, employe le plus souvent sous forme de barreaux de 20 a 40 mm de diametre, se trouve soumis a un ensemble de contraintes qui provoque des deformations irreversibles, le plus souvent incompatibles avec l'infrastructure du reacteur. Par consequent, le materiau combustible doit presenter a l'origine un certain nombre de qualites qu'il est necessaire de determiner. Aussi a-t-on d'abord etudie les caracteres technologiques propres a chacune des trois phases allotropiques de l'uranium-metal pur et leurs interactions sur la stabilisation du materiau constitue soit par de l'uranium coule, soit par de l'uranium traite en pile en phase {gamma}. (auteur)

  19. Modélisation informatique de la production d’énergie renouvelable à partir de biogaz par transformation anaérobique dumélange de résidus d’agrumes et defumier de bovins

    Directory of Open Access Journals (Sweden)

    Edwin Dario Cendales L.

    2014-03-01

    Full Text Available Dans cet article nous avons simulé par ordinateur le processus de digestion anaérobique d’un mélange homogénéisé de fumier bétail et de résidus d’agrumes afin d’évaluer la viabilité des énergies renouvelables à partir de la transformation des déchets. Sur la base des résultats obtenus et grâce au développement de la phase expérimentale lors de laquelle étaient mesurées de façon périodiques les variables de contrôle du processus de biodégradation anaérobique tels que le pH, l’alcalinité, la demande chimique en oxygène (total et soluble, nous avons établi les performances des paramètres du processus et déterminé des valeurs pour la comparaison entre résultats expérimentaux et résultats informatiques. Nous avons en outre réalisé une simulation du processus de digestion anaérobique dans des conditions similaires à celles précédemment établis par d’autres essais expérimentaux à travers la mise en oeuvre du modèle ADM-1. Grâce aux résultats obtenus par le biais de simulations et mesures expérimentales, nous avons évalué la précision du modèle concernant les valeurs des mesures expérimentales. Un modèle simplifié pour l’évaluation de l’énergie produite par une installation à échelle réduite qui effectue le traitement anaérobique des résidus organiques a finalement été mis en place. Le modèle a montré qu’il existe au départ un déficit énergétique pour que le processus se réalise, mais une fois la production de biogaz enclenchée, le processus devient autonome et le système fournit une quantité croissante d’énergie disponible.

  20. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960); Elimination par dilution d'effluents liquides faiblement radioactifs. Leurs consequences (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Candillon, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [French] Les centres nucleaires ont frequemment a resoudre des problemes poses par l'elimination de volumes importants d'effluents liquides faiblement radioactifs. Dans l'etat actuel des choses, la solution la plus utilisee consiste a rejeter ces effluents dans le reseau hydrographique de maniere a les diluer au maximum et abaisser ainsi leurs teneurs en isotopes radioactifs au-dessous des normes imposees par la Sante Publique. Cette technique necessite un controle systematique du reseau et de ses dependances et demande une connaissance approfondie des processus d'adsorption et de fixation. (auteur)

  1. Factors and uncertainties in the profitability of using nuclear energy in desalination of water; Facteurs et incertitudes de la rentabilite du recours a l'energie nucleaire dans le dessalement des eaux

    Energy Technology Data Exchange (ETDEWEB)

    Thiriet, L; Lievre, P [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    One of the economic advantages of nuclear energy consists of the small proportional element in its cost structure. Economies of scale favour the nuclear station as compared with the conventional thermal one, and when the demand for electricity and heat, in particular for desalination, are sufficient, nuclear energy may, subject to certain conditions, prove advantageous. The object of this paper is to discuss the validity of the conclusions reached according to the hypotheses adopted. In the first part, the different kind of uncertainties connected with technical, economic and financial data (the various transmission coefficients, the life of equipment according to the choice of materials, changes in prices, the form of price functions and interest rates), and with the various constraints, are examined and discussed. In the second part the uncertainties connected with the method of optimisation used and the criterion of selection adopted are examined and discussed. It is shown thereby that it is usually extremely difficult to assume absolutely the competitiveness, or conversely the non-competitiveness, of using nuclear energy in the desalination of water, and that a large number of aspects have to be carefully examined. (author) [French] On sait que l'un des avantages economiques de l'energie nucleaire reside dans la faible part proportionnelle dans la structure de son cout. Les economies d'echelle favorisent le nucleaire par rapport au thermique classique, et lorsque les demandes d'electricite et de chaleur, notamment pour le dessalement, sont suffisantes on peut envisager favorablement, sous certaines hypotheses, le recours a l'energie nucleaire. L'objet de cette communication est de discuter la validite des conclusions auxquelles on parvient selon les hypotheses envisagees. Dans une premiere partie, on etudie et on discute les differentes sortes d'incertitudes, liees aux donnees techniques, economiques et financieres (les divers coefficients de transmission, les

  2. MESUR metrics from scholarly usage of resources

    CERN Document Server

    CERN. Geneva; Van de Sompel, Herbert

    2007-01-01

    Usage data is increasingly regarded as a valuable resource in the assessment of scholarly communication items. However, the development of quantitative, usage-based indicators of scholarly impact is still in its infancy. The Digital Library Research & Prototyping Team at the Los Alamos National Laboratory's Research library has therefore started a program to expand the set of usage-based tools for the assessment of scholarly communication items. The two-year MESUR project, funded by the Andrew W. Mellon Foundation, aims to define and validate a range of usage-based impact metrics, and issue guidelines with regards to their characteristics and proper application. The MESUR project is constructing a large-scale semantic model of the scholarly community that seamlessly integrates a wide range of bibliographic, citation and usage data. Functioning as a reference data set, this model is analyzed to characterize the intricate networks of typed relationships that exist in the scholarly community. The resulting c...

  3. Quand les proverbes français explicitent l’humain par le biais pronominal (qui/on ou nominal (homme/femme

    Directory of Open Access Journals (Sweden)

    Mercedes Banegas Saorín

    2016-12-01

    Full Text Available Nous nous penchons ici sur les proverbes introduits par les pronoms et par des syntagmes nominaux pour déterminer dans quelle mesure la structure syntaxique joue sur la structure informative de ces énoncés qui acquièrent un sens conventionnel codé. Nous les rapprochons des énoncés génériques, sans perdre de vue les propriétés auxquelles satisfont la plupart des proverbes : généricité, schéma implicatif et montée hypo-hypéronymique. Comme la classe des proverbes n’est pas formellement homogène, nous aboutissons, d’une part, à l’établissement d’une sous-classe des proverbes dits pronominaux et, d’autre part, à une nouvelle typologie des proverbes, très proche de celle des phrases génériques qui fait consensus.

  4. Nuclear developments at the international inter govern mental level (1961); Developpements nucleaires sur le plan international intergouvernemental (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Waynbaum, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The United Nations organisation and nuclear energy rose simultaneously, in 1945, to occupy an important place in the public eye. The spiritual succession of the League of Nations which had foundered during the war was taken up by the new organisation which sought to implant its political ideal in a more tangible reality, so that it might thereby be inspired by concrete and substantial objectives. This is one of the reasons for the existence of the dozen specialized agencies created by the family of the United Nations and dealing with Health, Culture, Agriculture, Finance, etc. Nuclear energy is one of these techniques. Becoming suddenly an important power factor and exploiting for itself the prestige of Science, it became the favorite domain for the growth of this new spirit, as much in its universal form in 1945 as in its more regional form which it was later to adopt. The achievements are numerous and of varying importance; they deserve te be studied carefully. (author) [French] L'organisation des Nations Unies et le nucleaire ont ete places simultanement, en 1945, au premier plan de la scene mondiale. La Societe des Nations ayant sombre pendant la guerre, son heritage spirituel fut recueilli par la nouvelle organisation qui chercha a enraciner son ideal politique dans une realite plus materielle, de facon a y puiser une nourriture concrete et substantielle. C'est une des raisons d'existence de la douzaine d'institutions specialisees gravitant dans la famille des Nations Unies et s'occupant de Sante, de Culture, d'Agriculture, de Finances, etc. Le nucleaire est l'une de ces techniques. Devenu soudainement un facteur primordial de puissance, Cristallisant a son benefice le prestige de la Science, c'etait un terrain de predilection pour le developpement du nouvel esprit, aussi bien sous la forme universelle de 1945, que sous les formes regionales qui ont vu le jour ensuite. Les travaux realises que nombreux, d'importance tres inegale. Ils meritent qu'on les examine

  5. Nuclear developments at the international inter govern mental level (1961); Developpements nucleaires sur le plan international intergouvernemental (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Waynbaum, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The United Nations organisation and nuclear energy rose simultaneously, in 1945, to occupy an important place in the public eye. The spiritual succession of the League of Nations which had foundered during the war was taken up by the new organisation which sought to implant its political ideal in a more tangible reality, so that it might thereby be inspired by concrete and substantial objectives. This is one of the reasons for the existence of the dozen specialized agencies created by the family of the United Nations and dealing with Health, Culture, Agriculture, Finance, etc. Nuclear energy is one of these techniques. Becoming suddenly an important power factor and exploiting for itself the prestige of Science, it became the favorite domain for the growth of this new spirit, as much in its universal form in 1945 as in its more regional form which it was later to adopt. The achievements are numerous and of varying importance; they deserve te be studied carefully. (author) [French] L'organisation des Nations Unies et le nucleaire ont ete places simultanement, en 1945, au premier plan de la scene mondiale. La Societe des Nations ayant sombre pendant la guerre, son heritage spirituel fut recueilli par la nouvelle organisation qui chercha a enraciner son ideal politique dans une realite plus materielle, de facon a y puiser une nourriture concrete et substantielle. C'est une des raisons d'existence de la douzaine d'institutions specialisees gravitant dans la famille des Nations Unies et s'occupant de Sante, de Culture, d'Agriculture, de Finances, etc. Le nucleaire est l'une de ces techniques. Devenu soudainement un facteur primordial de puissance, Cristallisant a son benefice le prestige de la Science, c'etait un terrain de predilection pour le developpement du nouvel esprit, aussi bien sous la forme universelle de 1945, que sous les formes regionales qui ont vu le jour ensuite. Les travaux realises que nombreux, d

  6. Measurement of the electronic density of ionised media by hyper frequency methods; Mesure de la densite electronique des milieux ionises par des methodes hyperfrequences

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Within the limits of the I.N.S.T.N. courses on plasmas, this analytical study summarizes the articles quoted in the references on hyper-frequency techniques for the measurement of electronic density of an ionised gas. It is neither exhaustive nor complete and further details may be obtained by referring to the works mentioned. The first part, devoted to the theoretical side, concert the propagation of electromagnetic waves ionised media and the excitation of stationary raves in electromagnetic cavities. The second part deals with the measurement techniques themselves. It includes those techniques which hare become classic, and also more recent ones being developed in various laboratories and in the Service of Applied Physics at Saclay. (author) [French] Dans le cadre des cours sur les plasmas a l'l.N.S.T. cette etude d'analyse resume les articles cites en bibliographie sur les techniques hyperfrequences pour la mesure de la densite electronique d'un gas ionise. Elle n'est ni exhaustive, ni complete. Pour plus de details on voudra bien se rapporter aux travaux mentionnes. La premiere partie consacree a des rappels theoriques, concerne la propagation des ondes electromagnetiques dans les milieux ionises et sur l'excitation d'ondes stationnaires dans les cavites electromagnetiques. La seconde se rapporte aux techniques de mesures proprement dites. On a fait figurer dans cette partie des techniques devenues classiques et celles plus recentes en cours d'etudes dans divers laboratoires et au Service de Physique Appliquee a SACLAY. (auteur)

  7. Utilisation d'une sonde fluorimétrique benthique (la BenthoTorch, bbe) pour mesurer la croissance des diatomées, algues vertes et cyanobactéries périphytiques en plans d'eau

    OpenAIRE

    Roubeix, V.

    2015-01-01

    / Une sonde fluorimétrique benthique, la BenthoTorch (bbe) a été acquise par le pôle Onema-Irstea d'Hydroécologie des Plans d'eau pour développer un indice fonctionnel de production primaire dans les plans d'eau. Cet indice sera basé sur la dynamique de croissance du périphyton sur des substrats artificiels. Il constituerait un outil de diagnostic du fonctionnement écologique des systèmes lentiques, particulièrement utile dans le cadre du suivi de mesures de restauration. La BenthoTorch me...

  8. Protection of personnel against atmospheric contamination by plutonium in the laboratory (1963); Protection du personnel contre la contamination atmospherique par le plutonium, dans les laboratoires (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Feliers, P; Pomarola, J; Risselin, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1963-07-01

    Various problems about measurement of atmospheric contamination by plutonium in laboratories are considered. In particular are studied sampling methods, continuous measurement for alarm, criteria used for fixation of the concentrations to be measured, sensitivity of apparatus and effects of natural atmospheric contamination. The means actually available for measurement of contamination and their limits of use are briefly analysed. (authors) [French] Les differents problemes a resoudre pour realiser un controle satisfaisant de la contamination atmospherique par le plutonium, dans les laboratoires, sont abordes. On etudie en particulier les differents modes d'echantillonnage, le controle continu en vue de l'alarme, les criteres qui servent a la fixation des concentrations a mesurer, la sensibilite a donner aux moyens de mesure, les difficultes provenant de la contamination atmospherique naturelle. Les moyens actuellement disponibles pour le controle de la contamination et leurs moyens limites d'emploi sont analyses sommairement. (auteurs)

  9. CHARACTERISATION AND MEASUREMENT TO THE SUB-MICRON SCALE OF A REFERENCE WIRE POSITION CARACTERISATION ET MESURE SUB-MICROMETRIQUE DE LA POSITION D’UN FIL DE REFERENCE

    CERN Document Server

    SANZ , Claude; MAINAUD DURAND , Hélène; MORANTZ , Paul; SHORE , Paul

    2015-01-01

    L’étude suivante est réalisée dans le cadre du projet PACMAN (a study on Particle Accelerator Components Metrology and Alignment to the Nanometre scale) : une étude sur la métrologie et l’alignement à l’échelle nanométrique des composants d’un accélérateur de particules. C’est un programme Marie Curie supporté par la Commission Européenne et hébergé par le CERN. Le but de ce programme est de faire travailler en équipe de jeunes chercheurs sur le développement d’un banc de pré-alignement pour l’accélérateur linéaire CLIC (Compact Linear Collider). Sur ce banc, chaque composant sera aligné au niveau requis en une seule opération basée sur l’utilisation d’un fil tendu. Pendant cette opération, le fil matérialisera les axes magnétiques et électriques des composants, c’est-à-dire qu’il sera à la position théorique du faisceau de particules. Puis il servira de référence et la position de son axe sera mesurée avec autant de précision que possible par une machin...

  10. Spin correlation parameters A{sub xx} and A{sub yy} measurements in p-p scattering from 11 to 26 MeV; Mesure des coefficients de correlation de spins A{sub xx} et A{sub yy} dans la diffusion p-p de 11 a 26 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Catillon, Ph; Chapellier, M; Garreta, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The A{sub xx} and A{sub yy} spin correlation coefficients of the proton-proton scattering have been measured at the laboratory energies of 11,40 - 19,15 - 23,45 and 26,50 MeV for the center of mass scattering angle 90 degrees. These measurements have been made by scattering a polarized proton beam on a polarized proton target. (authors) [French] Les coefficients de correlation de spins A{sub xx} et A{sub yy} de la diffusion proton-proton ont ete mesures aux energies laboratoire de 11,40 - 19,15 - 23,45 et 26,50 MeV pour un angle de diffusion dans le centre de masse egal a 90 degres. Ces mesures ont ete effectuees par la diffusion d'un faisceau de protons polarises sur une cible de protons polarises. (auteur)

  11. Measurement of the local void fraction in two-phase air-water flow with a hot-film anemometer; Mesure du taux de vide local en ecoulement diphasique eau-air par un anemometre a film chaud

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, J. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    The experimental knowledge of the local void-fraction is basic for the derivation of the constitutive equations of two-phase flows. This report deals with measurements of the local void-fraction based on the use of a constant temperature hot-film anemometer associated with a multichannel analyser. After determining the void-fraction profile along a diameter of a vertical pipe (40 mm I.D.), in which air and water flow upwards, we compare the void-fraction averaged over the diameter with the average value measured directly by a {gamma}-ray method. Two runs were made in bubble flow and a third in slug flow. The two methods give results in a good agreement especially for bubble flow. The void-fraction averaged over the cross-section was also calculated from the different profiles and compared in a good manner with the experimental results of R. ROUMY. For bubble flow we verified the theory of S.G. BANKOFF about the shape of the void-fraction profiles. (author) [French] Nous proposons une methode de mesure du taux de vide local a en ecoulement diphasique, basee sur l'emploi d'un anemometre a film chaud a temperature constante dont on etudie la repartition du signal en amplitude dans un analyseur multicanaux. Ayant trace un profil de taux de vide local suivant un diametre d'une conduite verticale de section circulaire parcourue par un ecoulement ascendant d'eau et d'air, nous avons compare la moyenne de {alpha} sur ce diametre a la valeur obtenue par une methode d'absorption de rayons {gamma}. Les essais ont ete faits en ecoulements a bulles et a bouchons. Les deux methodes donnent des resultats concordants en particulier pour les ecoulements a bulles. Le taux de vide moyenne dans la section, calcule a partir des differents profils, a egalement ete compare avec succes aux resultats experimentaux de R. ROUMY. Dans l'etude de la structure radiale des ecoulements a bulles, nous avons verifie l'hypothese de S.G. BAJMKOFF. (auteur)

  12. Measurement of the local void fraction in two-phase air-water flow with a hot-film anemometer; Mesure du taux de vide local en ecoulement diphasique eau-air par un anemometre a film chaud

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    The experimental knowledge of the local void-fraction is basic for the derivation of the constitutive equations of two-phase flows. This report deals with measurements of the local void-fraction based on the use of a constant temperature hot-film anemometer associated with a multichannel analyser. After determining the void-fraction profile along a diameter of a vertical pipe (40 mm I.D.), in which air and water flow upwards, we compare the void-fraction averaged over the diameter with the average value measured directly by a {gamma}-ray method. Two runs were made in bubble flow and a third in slug flow. The two methods give results in a good agreement especially for bubble flow. The void-fraction averaged over the cross-section was also calculated from the different profiles and compared in a good manner with the experimental results of R. ROUMY. For bubble flow we verified the theory of S.G. BANKOFF about the shape of the void-fraction profiles. (author) [French] Nous proposons une methode de mesure du taux de vide local a en ecoulement diphasique, basee sur l'emploi d'un anemometre a film chaud a temperature constante dont on etudie la repartition du signal en amplitude dans un analyseur multicanaux. Ayant trace un profil de taux de vide local suivant un diametre d'une conduite verticale de section circulaire parcourue par un ecoulement ascendant d'eau et d'air, nous avons compare la moyenne de {alpha} sur ce diametre a la valeur obtenue par une methode d'absorption de rayons {gamma}. Les essais ont ete faits en ecoulements a bulles et a bouchons. Les deux methodes donnent des resultats concordants en particulier pour les ecoulements a bulles. Le taux de vide moyenne dans la section, calcule a partir des differents profils, a egalement ete compare avec succes aux resultats experimentaux de R. ROUMY. Dans l'etude de la structure radiale des ecoulements a bulles, nous avons verifie l'hypothese de S.G. BAJMKOFF. (auteur)

  13. A study of filtering problems of background noise in nuclear spectrometry, improvement of signal-to-noise ratio, and of pulse characteristics produced by the optimum predictor device; Etude de problemes de filtrage de bruit de fond en spectrometrie nucleaire, amelioration du rapport signal sur bruit et des caracteristiques de l'impulsion mise en forme par le dispositif du predicteur optimum

    Energy Technology Data Exchange (ETDEWEB)

    Benda, J [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1967-05-01

    The purpose of nuclear spectrometry is the precise measurement of particles energy. The resolving power of a spectrometer design is an important factor. Two main phenomena are involved in the limitation of this resolving power: The statistical fluctuations of the detector itself, and the background noise. For a given noise, the theory of filters enables the calculation of networks specially designed for the improvement of signal to noise ratio. The proposed system should lead to an improvement of 10.5 per cent of this ratio. Experiments have confirmed this theoretical estimation. The predictor device also makes possible the obtaining of shortened pulses. (author) [French] Les mesures en spectrometrie nucleaire ont pour but la determination precise de l'energie des particules. Le pouvoir de resolution d'une chaine de spectrometrie est une caracteristique importante. Deux phenomenes principaux concourent a limiter ce pouvoir de resolution: les fluctuations statistiques du detecteur et le bruit de fond. Pour un bruit de fond donne, la theorie des filtres permet de calculer des reseaux susceptibles de modifier le rapport signal sur bruit. Le systeme propose permet d'ameliorer de 10.5 pour cent ce rapport lorsqu'on se place dans les conditions optimales. Les resultats experimentaux confirment les previsions. Le dispositif predicteur permet aussi un raccourcissement de l'impulsion dans le temps. (auteur)

  14. Measurement of wave number spectrums; Mesure des spectres de nombres d'onde

    Energy Technology Data Exchange (ETDEWEB)

    Perceval, F. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-03-01

    To measure wave lengths in an ionized medium, the cross-correlation product of the signal collected by a fixed probe and that collected by a movable one exploring the medium, is carried out by an interferometer. In order to determine the various modes, we have made a device which computes the Fourier transform of the signal. The influence of the phase at the origin, of the damping of the signal and of the finite explored length has been studied in order to make a numerical calculation of the Fourier transform. (author) [French] Pour mesurer des longueurs d'onde dans un milieu ionise, nous effectuons a l'aide d'un interferometre un produit d'intercorrelation entre le signal collecte par une sonde fixe et celui d'une sonde mobile explorant le milieu. Afin de pouvoir determiner les differents modes constituant ces signaux, nous avons realise un dispositif qui effectue l'analyse de Fourier de tels enregistrements. L'influence de la phase a l'origine, de l'amortissement du signal et de la longueur finie d'exploration, a ete etudiee en vue du calcul numerique de la transformee de Fourier. (auteur)

  15. MESUR: metrics from scholarly usage of resources

    CERN Multimedia

    CERN. Geneva

    2007-01-01

    The MESUR project is constructing a large-scale semantic model of the scholarly community that seamlessly integrates a wide range of bibliographic, citation and usage data. Functioning as a reference data set, this model is analyzed to characterize the intricate networks of typed relationships that exist in the scholarly community. The resulting ...

  16. Professional Nuclear Materials Management; Gestion Industrielle des Matieres Nucleaires; Obrashchenie s yadernymi materialami na professional'nom urovne; Administracion Eficiente de Materiales Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Forcella, A. A.; O' Leary, W. J. [Allis-Chalmers Manufacturing Company, Bethesda, MD (United States)

    1966-02-15

    . (author) [French] Le memoire expose en quoi consiste la gestion des matieres nucleaires dans une centrale nucleaire type, aux Etats-Unis. Comme le reacteur en question est partiellement finance a l'aide de capitaux prives, l'une des principales obligations de l'exploitant est d'assurer la protection et la rentabilite des investissements. Etant donne que les matieres nucleaires sont d'une valeur intrinseque elevee, il faut constamment proceder a des controles appropries allant au-dela des mesures de securite et de la comptabilite interessant les matieresnucleaires proprement dites afin de reduire les pertes au minimum. Il faut faire preuve de clairvoyance et planifier judicieusement pour prevenir toute perte supplementaire de capital provenant de frais inutiles ou d'un manque a gagner dans divers secteurs de l'exploitation. C'est ainsi que le gestionnaire de matieres nucleaires doit prendre des dispositions pour garantir la bonne marche des operations et assurer le respect des plans d'execution par une liaison et un controle constants, dans les domaines suivants? a) acquisition du combustible et des elements combustibles, b) utilisation des elements combustibles dans le reacteur et c) recuperation, dans le combustible irradie, des produits et matieres presentant de l'interet. Pendant la periode qui precede l'utilisation du reacteur, il faut faire une place importante dans la planification et les travaux preparatoires aux considerations d'economie dans la conception des elements combustibles, en ce qui concerne leur fabrication, leur manutention, leur transport et leur remplacement. Les differentes etapes de la fabrication doivent etre planifiees de facon a reduire au minimum le manque a gagner du a des periodes improductives d'entreposage de matieres tres couteuses. Pendant la marche du reacteur, il faut assurer une combustion maximale de la matiere fissile par des redistributions appropriees du combustible dans le coeur du reacteur. Parallelement, les temps morts dus a

  17. Contribution to the study of several chemical hazards in the Centre d'Etudes Nucleaires of Fontenay-aux-Roses; Contribution a l'etude de quelques nuisances chimiques au centre d'etudes nucleaires de Fontenay-aux-Roses

    Energy Technology Data Exchange (ETDEWEB)

    Megemont, C; Grau, C [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-10-01

    From the checking of 2750 index cards of hazards, the study relates the distribution of the chemical hazards in the Centre d'Etudes Nucleaires of Fontenay-aux-Roses. Those concerning the greatest number of agents in the Centre are classified according to the categories corresponding to the different conditions of working. Thus, the most important are put forward. Then, the authors rapidly make a review of hazards which may have some special interest because they appear more specific of the nuclear energy or because they are the most frequently noted on the index cards of hazards. The case of the tributylphosphate is studied more precisely. (authors) [French] A partir de l'examen de 2750 fiches de nuisances, l'etude porte sur la repartition des nuisances chimiques au Centre d'Etudes Nucleaires de Fontenay-aux-Roses. Celles qui concernent le plus grand nombre d'agents du Centre sont classees selon les categories correspondant aux differentes conditions de travail. Les plus importantes d'entre elles sont ainsi mises en evidence. | Les auteurs passent ensuite en revue, rapidement, les nuisances qui peuvent presenter un interet particulier soit parce qu'elles semblent plus specifiques de l'Energie Nucleaire, soit parce qu'on les rencontre le plus frequemment sur les fiches de nuisances. Le cas du tributylphosphate est envisage de facon plus detaillee. (auteurs)

  18. Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs

    Energy Technology Data Exchange (ETDEWEB)

    Le Tilly, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-12-01

    The instantaneous value of the counting rate of the pulses given by a fission detector settled in a reactor follows the neutron flux, but it is shown that the counter adds a white noise to the measured signal. This report deals with some possibilities of on line numerical handling afforded by this kind of signals. One considers first the influence of a by N numerical divider and one shows that, acting like a quantifier, it adds to the signal a white noise with the power N{sup 2}/{sub 12}. One, studies afterwards the principle of a digital filter aimed to Fourier analyse the signal. The realization of this device is described. It can be used in transfer function measurements at frequencies below 125 kHz. Some examples of experiments performed with this apparatus are presented. One discusses finally the design, according to the same principle, of a power spectral density analyser in the frequency range 0,01 - 10 000 Hz for random signal of the same kind. (author) [French] La valeur instantanee de la frequence de recurrence des impulsions issues d'un detecteur a fission place dans un reacteur est proportionnelle au flux neutronique. Apres avoir montre que le detecteur ajoute un bruit blanc au signal mesure, on etudie clans ce rapport certaines possibilites de traitement numerique en temps reel offertes par ce type de signaux. On examine d'abord l'influence d'un diviseur numerique par N, et l'on montre que son action, semblable a une quantification, ajoute au signal un bruit blanc de puissance N{sup 2}/{sub 12}. On, etudie ensuite le principe d'un filtre numerique destine a effectuer l'analyse de Fourier du signal, et l'on decrit la realisation de cet appareil qui peut etre utilise pour mesurer des fonctions de transfert a une frequence quelconque inferieure a 10 kHz. Des exemples de mesures faites avec cet appareil sont presentes. On discute enfin la possibilite de realiser suivant le meme principe un analyseur de densite spectrale dans la bande de frequence 0,01 Hz

  19. Analysis of the accuracy of certain methods used for measuring very low reactivities; Analyse de la precision de certaines methodes de mesure de tres basses reactivites

    Energy Technology Data Exchange (ETDEWEB)

    Valat, J; Stern, T E

    1964-07-01

    The rapid measurement of anti-reactivities, in particular very low ones (i.e. a few tens of {beta}) appears to be an interesting method for the automatic start-up a reactor and its optimisation. With this in view, the present report explores the various methods studied essentially from the point of view of the time required for making the measurement with a given statistical accuracy, especially as far as very low activities are concerned. The statistical analysis is applied in turn to: the methods for the natural background noise (auto-correlation and spectral density); the sinusoidal excitation methods for the reactivity or the source, with synchronous detection ; the periodic source excitation method using pulsed neutrons. Finally, the statistical analysis leads to the suggestion of a new method of source excitation using neutronic random square waves combined with an intercorrelation between the random excitation and the resulting output. (authors) [French] La mesure rapide des antireactivites, en particulier celle des tres basses (soit quelques dizaines de {beta}), apparait comme une voie interessante pour le demarrage automatique d'un reacteur et son optimalisation. Dans cette optique, le present rapport explore diverses methodes etudiees essentiellement sous l'angle de la duree de mesure necessaire a une precision relative statistique donnee, plus particulierement en ce qui concerne les tres basses reactivites. L'analyse statistique porte successivement sur: les methodes du bruit de fond naturel (autocorrelation et densite spectrale); les methodes d'excitation sinusoidale de reactivite ou de source, avec detection synchrone; la methode d'excitation periodique de source par neutrons pulses. Enfin l'analyse statistique amene a proposer une methode nouvelle d'excitation de source par creneaux neutroniques aleatoires alliee a une intercorrelation entre l'excitation aleatoire et la sortie resultante. (auteurs)

  20. MESUR: USAGE-BASED METRICS OF SCHOLARLY IMPACT

    Energy Technology Data Exchange (ETDEWEB)

    BOLLEN, JOHAN [Los Alamos National Laboratory; RODRIGUEZ, MARKO A. [Los Alamos National Laboratory; VAN DE SOMPEL, HERBERT [Los Alamos National Laboratory

    2007-01-30

    The evaluation of scholarly communication items is now largely a matter of expert opinion or metrics derived from citation data. Both approaches can fail to take into account the myriad of factors that shape scholarly impact. Usage data has emerged as a promising complement to existing methods o fassessment but the formal groundwork to reliably and validly apply usage-based metrics of schlolarly impact is lacking. The Andrew W. Mellon Foundation funded MESUR project constitutes a systematic effort to define, validate and cross-validate a range of usage-based metrics of schlolarly impact by creating a semantic model of the scholarly communication process. The constructed model will serve as the basis of a creating a large-scale semantic network that seamlessly relates citation, bibliographic and usage data from a variety of sources. A subsequent program that uses the established semantic network as a reference data set will determine the characteristics and semantics of a variety of usage-based metrics of schlolarly impact. This paper outlines the architecture and methodology adopted by the MESUR project and its future direction.

  1. Measurement of the quantity of water in organic solvents by infrared absorption an measurement of the dielectric constants; Dosage de l'eau dans les solvants organiques par absorption infra-rouge et mesure des constantes dielectriques

    Energy Technology Data Exchange (ETDEWEB)

    Desnoyer, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    Some chemical methods for the analysis of the quantity of water in solvents are first described, their object being the determination of the maximum error for cases where the water content is less than 1 per cent. - The first part of the work consists in describing infrared spectrometry as applied to the analysis of water in carbon tetrachloride, chloroform aniline, acetone and dioxane. A method based on isotopic exchange between heavy and light water is used on the one hand for determining the solubility of water in carbon tetrachloride and on the other hand for establishing standard solutions (sensitivity of the method). - In the second part the dielectric constant of water solvent solutions is measured. A table is presented giving the precision obtained by the two principal methods. These are comparable and further than that the appearance of the spectra suggests an interpretation of the anomalies observed in calibration curves obtained by the dielectric constant method. (author) [French] Quelques methodes chimiques d'analyses de l'eau dissoute dans les solvants sont decrites tout d'abord en vue de determiner l'erreur maxima dans le cas ou la teneur en eau ne depasse pas 1 pour cent. - Une premiere partie du travail expose la technique utilisee en spectrometrie infrarouge pour doser l'eau dans le tetrachlorure de carbone, chloroforme, aniline, acetone et le dioxane. Une methode basee sur l'echange isotopique entre l'eau legere et l'eau lourde permet de determiner d'une part la solubilite de l'eau dans le tetrachlorure de carbone et le chloroforme et d'autre part le titre en valeur absolue des solutions etalons (sensibilite de la methode). - Dans une deuxieme partie, on mesure la constante dielectrique des solutions eau-solvant. On dresse un tableau des precisions obtenues par les deux methodes principales. Celles-ci sont comparables et en outre, l'aspect du spectre suggere une interpretation des anomalies observees dans les courbes d'etalonnage tracees par la

  2. Spectroscopie résolue en temps par continuum femtoseconde Applications en neurobiologie

    Science.gov (United States)

    Ramstein, S.; Mottin, S.

    2003-06-01

    La spectroscopie résolue en temps utilisant un laser blanc femtoseconde est appliquée à la mesure in vivo des principaux absorbeurs du cerveau. Après génération adéquate du continuum de lumière blanche femtoseconde (50mW/[580-756nm] à 1Hz), cette source se propage dans la calvaria, les méninges et le cortex chez le rat anesthésié. La transmission est étudiée sur 7mm de distance entre l'impact laser et la fibre optique de collection. Le signal transmis est analysé dans la fenêtre 580-760nm, par un spectromètre couplé à une caméra à balayage de fente permettant la décorrélation de l'absorption et de la diffusion.

  3. Gamma radiation in space and in the atmosphere; Rayonnement gamma dans l'espace et dans l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Rocchia, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    We have shown that the {gamma} radiation existing in the atmosphere is caused mainly by the Bremsstrahlung of the electrons of the electromagnetic cascades ({approx} 50 per cent of the measured radiation), by the 511 keV radiation produced by the annihilation of positrons created in cascades (8 per cent of the measured intensity) and by the Compton {gamma} degradation of this line (30 per cent of the measured intensity). The rest, slightly over 10 per cent, must be attributed to secondary causes such as the nuclear de-excitation {gamma} to the internal Bremsstrahlung of charged particles created in nuclear stars, and to charged particles crossing our detector, since the latter was not fitted with a device for rejecting these particles. Experiments carried out in rockets at Colomb-Bechar confirm these results and have made it possible to detect and measure a primary {gamma} radiation having an intensity of {approx} 2 {gamma} cm{sup 2} s{sup -1} above 100 keV. The primary spectrum obeys an approximate E{sup -2} law. (author) [French] Nous avons montre que le rayonnement {gamma} existant dans l'atmosphere est provoque principalement por le bremsstrohlung des electrons des cascades electromagnetiques ({approx} 50 pour cent du rayonnement mesure), au rayonnement 511 keV provoque par l'annihilation des positrons crees dans les cascades (8 pour cent de l'intensite mesuree) et aux {gamma} de degradation Compton de cette raie (30 pour cent de l'intensite mesuree). Le reste, soit un peu plus de 10 pour cent, doit etre attribue a des causes secondaires telles que les {gamma} de desexcitation nucleaire, le bremsstrahlung interne des particules chargees creees dans les etoiles nucleaires, et aux particules chargees traversant notre detecteur car celui-ci ne comportait pas de dispositif de rejet de ces particules. Les experiences faites en fusees a Colomb-Bechar ont confirme ces resultats et permis de detecter et mesurer un rayonnement {gamma} primaire dont l

  4. Damage caused to houses and equipment by underground nuclear explosions; Degats dus aux explosions nucleaires souterraines sur les habitations et les equipements

    Energy Technology Data Exchange (ETDEWEB)

    Delort, F; Guerrini, C [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    A description is given of the damaged caused to various structures, buildings, houses, mechanical equipment and electrical equipment by underground nuclear explosions in granite. For each type of equipment or building are given the limiting distances for a given degree of damage. These distances have been related to a parameter characterizing the movement of the medium; it is thus possible to generalize the results obtained in granite, for different media. The problem of estimating the damage caused at a greater distance from the explosion is considered. (authors) [French] Les degats sur diverses structures, constructions, habitations, equipements mecaniques et materiels electriques provoques par des explosions nucleaires souterraines dans le granite sont decrits. On a indique pour chaque type de materiel ou de construction, les distances limites correspondant a un degre de gravite de dommage observe. Ces distances ont ete reliees a un parametre caracterisant le mouvement du milieu, permettant ainsi de generaliser les resultats obtenus dans le granite, a differents milieux. Le probleme de la prevision des degats en zone lointaine a ete aborde. (auteurs)

  5. Contribution to the Study of Nuclear Magnetic Resonance in Ferromagnets; Contribution a l'etude de la resonance nucleaire dans les corps ferromagnetiques

    Energy Technology Data Exchange (ETDEWEB)

    Robert, C [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    Properties of nuclear magnetic resonance in the field acting on the nucleus in a ferromagnet were studied. Nuclei were {sup 57}Fe in iron and yttrium iron garnet. Static properties of resonance (frequency, line-width, dipolar structure) were investigated and compared with magnetic behavior and magnetic structure of the materials. Relaxation in garnet points out importance of long range fluctuations induced by impurities in a ferromagnetic lattice. (author) [French] Nous avons etudie les proprietes de la resonance nucleaire dans le champ existant a remplacement d'un noyau dans un corps ferromagnetique (champ local). Les noyaux etaient ceux de {sup 57}Fe dans le fer et dans le grenat d'yttrium et de fer. Les proprietes statiques de la resonance (frequence de resonance, largeur de la raie, structures dues a l'interaction dipolaire) ont ete etudiees et reliees aux caracteristiques magnetiques et a la structure de ces corps. La relaxation dans le grenat a mis en evidence les fluctuations a longue distance induites par des impuretes dans un reseau ferromagnetique. (auteur)

  6. Measurement of the anti reactivity of a control rod of G1, by a slow oscillation method; Mesure de l'antireactivite d'une barre de reglage de G1 pour une methode d'oscillation lente

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D; Leroy, J; Vidal, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    It is possible to determine the effect of the end of a control rod on the reactivity of the pile by measuring the modulation induced in the neutron flux by the slow oscillation of this control rod. The total effect of the control rod can be deduced, given certain hypothesis and corrections, from the experimental curve giving the effect of the end of the rod as a function of its position. This method has the advantage of permitting the measurement of very large anti reactivities, such as p= 10{sup -2} for example, which would not be possible by other kinetic methods. Thus the control rod B{sub 3}, in the low position, brings about a reduction in reactivity equal to 1130 p.c.m. {+-} 30 in the pile charged with 518 fuel elements, on one side only of the slit. We have compared the oscillation method with the classical divergence method, in the fields where the two measurements were possible: a satisfactory agreement was found. We have established that the phase displacement between the oscillation of the rod and the modulation of the flux varied greatly with the position of the rod. This variation cannot be explained on the basis of the dynamic model independent of space; we have attributed it to the influence of spatial harmonics of the flux distribution, and have determined a correction which frees the measurements of this influence. (author) [French] II est possible de determiner l'effet de l'extremite d'une barre de reglage sur la reactivite de la pile, a partir de la mesure de la modulation induite dans le flux neutronique par l'oscillation lente de cette barre de reglage. L'effet total de la barre de reglage peut etre deduit, moyennant certaines hypotheses et certaines corrections, de la courbe experimentale donnant l'effet de l'extremite de la barre en fonction de sa position. Cette methode a l'avantage de rendre possible la mesure d'antireactivites tres grandes, telles que p = 10{sup -2} par exemple, ce qui ne serait pas possible par d'autres methodes

  7. Measurement of the total ionisation intensity near the ground and separation of the various components; Mesure de l'intensite totale d'ionisation au voisinage du sol et separation de ses differentes composantes

    Energy Technology Data Exchange (ETDEWEB)

    Grevet, Ph [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-06-01

    The aim of this work is to measure the total amount of ion-pairs produced in the air per unit time and unit volume. It is possible, furthermore, by using continuous recording to study the variations in the ionisation due to {alpha}, {beta} and {gamma} radiation at a height of one metre. The apparatus which has been developed consists of two chambers of 120 litres: one, hermetically sealed detects the {gamma} component, the other with a circulation of the ambient air detects the {alpha} and {gamma}; it is thus possible by difference to evaluate the {alpha} component. The chambers and the associated electronic equipment have been designed for continuous operation in the open air. Another chamber without walls can be used for measuring directly the total ionisation intensity and from this an approximate calculation may be made of the {beta} component. A series of recordings has been made near Saclay where the natural radio-activity level is moderate, and in regions of low and high activity (near the sea and in the CEA's mining divisions). It has thus been possible to show the variation in the {gamma} component as a function of the geographic position of the measurement (from 3.7 to 6.3 l/cm{sup 3}.s), the very large variations of the {alpha} component at a given place with changing meteorological conditions (from 1.5 to 45 l/cm{sup 3}.s at Saclay for example) an the far smaller variations in the {beta} component. (author) [French] Le but de ce travail est de mesurer la quantite totale de paires d'ions produite dans l'air par unite de temps et de volume. Des enregistrements continus permettent, de plus, d'etudier les variations a 1 m du sol de cette ionisation due aux rayonnements {alpha}, {beta} et {gamma}. L'appareillage mis au point est forme de deux chambres de 120 litres: l'une hermetiquement fermee detecte la composante {gamma}; l'autre avec circulation de l'air ambiant detecte {alpha} + {gamma} ce qui permet d'evaluer par difference la composante {alpha}. Les

  8. Contribution to the study of nuclear fuel materials with a metallic uranium base; Contribution a l'etude des materiaux combustibles nucleaires a base d'uranium metallique

    Energy Technology Data Exchange (ETDEWEB)

    Englander, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-11-15

    In a power reactor destined to supply industrially recoverable thermal energy, the most economical source of heat still consists of natural metallic uranium. However, the nuclear fuel material, most often employed in the form of rods of 20 to 40 mm diameter, is subjected to a series of stresses which lead to irreversible distortions usually incompatible with the substructure of the reactor. As a result the fuel material must possess at the outset a certain number of qualities which must be determined. Investigations have therefore been carried out, first on the technological characters peculiar to each of the three allotropic phases of pure uranium metal, and on their interactions on the stabilisation of the material which consists of either cast uranium or uranium pile-treated in the {gamma} phase. (author) [French] Dans un reacteur de puissance destine a fournir de l'energie thermique industriellement recuperable, la source de chaleur la plus economique reste constituee par de l'uranium metallique naturel. Or, le materiau combustible nucleaire, employe le plus souvent sous forme de barreaux de 20 a 40 mm de diametre, se trouve soumis a un ensemble de contraintes qui provoque des deformations irreversibles, le plus souvent incompatibles avec l'infrastructure du reacteur. Par consequent, le materiau combustible doit presenter a l'origine un certain nombre de qualites qu'il est necessaire de determiner. Aussi a-t-on d'abord etudie les caracteres technologiques propres a chacune des trois phases allotropiques de l'uranium-metal pur et leurs interactions sur la stabilisation du materiau constitue soit par de l'uranium coule, soit par de l'uranium traite en pile en phase {gamma}. (auteur)

  9. Instruments used to measure or check {alpha}, {beta}, {gamma} activity and neutron emission in the course of processing ore or irradiated fuel; Appareils de mesure ou de controle {alpha}, {beta}, {gamma}, n, des circuits des usines de traitement du minerai ou du combustible irradie

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, A; Brunet, M; Kermagoret, M; Labeyrie, J; Roux, G; Vasseur, J; Weil, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    plutonium et des produits de fission dans les differents circuits, et sur la radioactivite des effluents rejetes par l'usine dans les cours d'eau. Le controle des operations de fixation et d'elution de l'uranium est effectue automatiquement par un appareil qui preleve, evapore et mesure l'activite {alpha} de 5 cm{sup 3} de solution toutes les 10 ou 20 minutes. Les teneurs en plutonium sont mesurees: - en presence de fortes activites {beta} {gamma} par des detecteurs {alpha} a cylindres tournants; - en presence de faibles activites {beta} {gamma} par des detecteurs {alpha} examinant une surface liquide a niveau constant; - par des chambres a fission peu sensibles aux {gamma}. Les teneurs en produits de fission sont mesurees par des chambres, compteurs, ou scintillateurs, selon l'importance de l'activite {gamma}. Enfin, le controle de l'activite des effluents a rejeter dans les cours d'eau est realise par un appareil a scintillation mesurant l'activite {alpha} d'une part et, d'autre part l'activite {alpha} {gamma} des residus d'un echantillon de 100 cm{sup 3} preleve et evapore en 20 minutes. (auteur)

  10. Tritium enrichment by thermal diffusion. I. Calculation of an installation for measuring natural tritium; Enrichissement du tritium par diffusion thermique. - I. Calcul d'une installation destinee a la mesure du tritium naturel

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M; Ravoire, J [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The natural content of tritium is so low that its measurement generally requires a preliminary enrichment. The thermal diffusion on hydrogen is studied as an enrichment method. The installation studied comprises two stages of columns of the hot-wire type, together with a device for transferring the tritium from the water sample into the hydrogen in the columns using catalytic exchange. A complete mathematical treatment for the operation of such a unit has been made and programmed for the IBM 7094 computer. An optimization has been effected by means of this program. It is shown that for similar performances, less hydrogen is retained in the case of hot-wire type columns than in the case of columns composed of concentric tubes. (authors) [French] La teneur naturelle du tritium est si faible que sa mesure demande generalement un enrichissement prealable. On etudie la diffusion thermique sur l'hydrogene comme moyen d'enrichissement. L'installation que l'on etudie comprend deux etages de colonnes du type fil chaud, et un dispositif de transfert du tritium de l'echantillon d'eau dans l'hydrogene des colonnes par echange catalytique. Un traitement mathematique complet du fonctionnement d'un tel ensemble a ete etabli et programme sur machine IBM 7094. Une optimisation a ete faite a l'aide du programme. On montre egalement qu'a performances egales, la retenue d'hydrogene est plus faible dans le cas des colonnes du type fil chaud que dans le cas des colonnes du type tubes concentriques. (auteurs)

  11. Le pilotage et la mesure de l’empreinte sociétale de l’entreprise grâce à la Balanced ScoreCard : entre adaptation et évolution radicale du modèle de Kaplan et Norton

    OpenAIRE

    Crutzen, Nathalie; Van Caillie, Didier

    2007-01-01

    Vu l’intérêt croissant porté par les entreprises aux aspects sociaux et environnementaux, la présente communication propose une revue des principales contributions montrant l’importance et les enjeux de la prise en compte des dimensions sociales et environnementales (de la RSE) dans les systèmes de contrôle de gestion des entreprises. Plus spécifiquement, face aux limites de nombreux outils pour piloter et mesurer adéquatement l’empreinte sociétale des entreprises, ce papier met en évide...

  12. Fission ionisation chamber for the measurement of low fluxes of slow neutrons; Chambre d'ionisation a fission pour la mesure des faibles flux de neutrons lents

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Duchene, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The ionisation chamber described is designed for the measurement of slow neutron fluxes of average or low intensity, in the presence, eventually, of very high gamma fluxes. The capture of a slow neutron by a fissile material, in this case {sup 235}U, gives rise to fission fragments, high-energy particles which ionise the gas contained in the chamber. The neutrons are detected by virtue of the potential pulses, on the collecting electrode of the chamber, deriving from the collection of the ions produced by the fission fragments. The pulses are counted by means of a measuring system consisting of a preamplifier, a 2 Mc amplifier, a discriminator and an electronic scale with numerator or integrator. The general characteristics are as follows: sensitivity to neutrons: 0.07 kicks/n/cm{sup 2}.s, sensitivity to {gamma} rays: zero up to 3.10{sup 4} R/H, a background noise at the normal discrimination voltage: 0.01 kicks/s, working H.T.: -500 V, capacity: 40 {mu}{mu}F, average height of pulse: 8 mV, limits of use: from several neutrons to 10{sup 6} n/cm{sup 2}.s. This chamber may be used in all cases where low fluxes of slow neutrons must be measured, especially in the presence of high gamma fluxes, for example in the checking of Pu concentrations in an extraction plant or for the starting up of reactors. (author) [French] La chambre d'ionisation decrite est destinee a la mesure des flux de neutrons lents d'intensite moyenne ou faible, en presence eventuelle de flux gamma tres importants. La capture d'un neutron lent par un materiau fissile, en l'occurrence {sup 235}U, donne naissance a des fragments de fission, particules de grande energie qui ionisent le gaz contenu dans la chambre. Les neutrons sont detectes grace aux impulsions de potentiel, sur l'electrode collectrice de la chambre, provenant de la collection des ions produits par les fragments de fission. Une chaine de mesure comprenant un preamplificateur, un amplificateur 2 Mc, un discriminateur, une echelle

  13. Contribution to the Study of Nuclear Magnetic Resonance in Ferromagnets; Contribution a l'etude de la resonance nucleaire dans les corps ferromagnetiques

    Energy Technology Data Exchange (ETDEWEB)

    Robert, C. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    Properties of nuclear magnetic resonance in the field acting on the nucleus in a ferromagnet were studied. Nuclei were {sup 57}Fe in iron and yttrium iron garnet. Static properties of resonance (frequency, line-width, dipolar structure) were investigated and compared with magnetic behavior and magnetic structure of the materials. Relaxation in garnet points out importance of long range fluctuations induced by impurities in a ferromagnetic lattice. (author) [French] Nous avons etudie les proprietes de la resonance nucleaire dans le champ existant a remplacement d'un noyau dans un corps ferromagnetique (champ local). Les noyaux etaient ceux de {sup 57}Fe dans le fer et dans le grenat d'yttrium et de fer. Les proprietes statiques de la resonance (frequence de resonance, largeur de la raie, structures dues a l'interaction dipolaire) ont ete etudiees et reliees aux caracteristiques magnetiques et a la structure de ces corps. La relaxation dans le grenat a mis en evidence les fluctuations a longue distance induites par des impuretes dans un reseau ferromagnetique. (auteur)

  14. Comparative Studies of Chemical Effects following Nuclear Reactions and Transformations on Metal Organic Phenyl Compounds; Etudes Comparatives des Effets Chimiques Induits par les Reactions et les Transformations Nucleaires sur des Composes Phenylmetalliques; 0421 0420 0410 0414 ; Estudios Comparativos de los Efectos Quimicos de las Reacciones y Transformaciones Nucleares en Compuestos Fenil-Organometalicos

    Energy Technology Data Exchange (ETDEWEB)

    Merz, E.; Riedel, H. J. [Kernforschungsanlage, Juelich, Federal Republic of Germany (Germany)

    1965-04-15

    molecule by the nuclear recoil and the resulting excitation. The hypothesis is put forward that the kind and quantity of certain new radioactive species produced in connection with nuclear events is less a function of the nature and concentration of primary recoil fragments than are the ions, radicals and lattice defects imparted to the irradiated materials by secondary recoil effects (elastic and inelastic interactions) , including the peculiar influence of oxygen. (author) [French] Les auteurs ont etudie les effets chimiques provoques par les atomes chaud de recul resultant des reactions nucleaires dans les solides et dans les liquides en se fondant sur une vaste comparaison des produits des processus (n,{gamma}) et (n,2n) dans les composes phenyles du germanium, de l'etain, du plomb, de l'arsenic et de l'antimoine. En outre, ils ont compare les produits de recul radioactifs formes apres capture K dans le tetraphenyl- germanium-{sup 68}Ge avec les resultats du processus (n,{gamma}) dans le triphenylgalliumet du processus (n,p) sur le tetraphenylgermanium. Enfin, ils ont etudie la transition {beta}{sup -} dans laquelle {sup 77}Ge est remplace par {sup 77}As dans le compose. En appliquant differentes methodes de separation, par exemple la chromatographie d'adsorption sur alumine, l'echange d'ions et l'electrophorese, ils ont separe les divers produits de recul radioactifs et determine les rendements individuels. Ils ont constate que, dans les reactions nucleaires, les composes des metaux cites ayant des coordinats identiques forment pratiquement les memes classes.de produits de recul. Toutefois, pour la distribution des rendements, il y a des differences caracteristiques entre la reaction (n,{gamma}) et la reaction (n,2n). L'influence sur les rendements est a peine perceptible lorsque les irradiations ont lieu dans des liquides ou des solutions. Mais les differences trouvees pour les nouveaux composes formes par des transformations nucleaires sont frappantes, en ce qui

  15. Intensité thérapeutique optimale : comment mesurer l'intensité d'une association radiothérapie-chimiothérapie ?

    Science.gov (United States)

    Ganem, G.; Dubray, B.

    1998-04-01

    Treatment intensification is needed to overcome the disappointing efficacy of anticancer treatments used as a single modality. The conception, comparison and optimization of radiotherapy - chemotherapy combinations is hampered by the lack of a common tool enabling the clinicians to quantify the effects of the association of different treatment modalities. Such a difficulty is mainly due to chemotherapy (large array of drugs, pharmacological uncertainties), but is also the consequence of end-point multiplicity (tumour control, normal tissue injury) and tumour biology complexity. L'intensification thérapeutique est une nécessité face à l'efficacité insuffisante des traitements anticancéreux utilisés séparément. La conception, la comparaison, et l'optimisation des modalités possibles d'association de radiothérapie et de chimiothérapie est considérablement gênée par l'absence d'un outil permettant de mesurer l'efficacitéé résultante de la combinaison d'agents thérapeutiques différents. Cette difficulté provient essentiellement de l'usage de la chimiothérapie (nombreuses drogues, pharmacocinétique mal connue), mais aussi de la multiplicité des critères de jugement (action anti-tumorale, lésions des tissus sains) et de la complexité de la biologie tumorale.

  16. The atomic energy course of the 'Institut National des Sciences et Techniques nucleaires' at the centre d'Etudes Nucleaires at Saclay; L'enseignement de genie atomique de l'Institut national des Sciences et Techniques nucleaires au Centre d'Etudes nucleaires de Saclay

    Energy Technology Data Exchange (ETDEWEB)

    Baissas, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    foreign students. 8- Annexe: list of courses, practical work, pile projects drawn up by the 1957 students. (author)Fren. [French] 1- Les raisons de sa creation. L'electricite de France et l'industrie interessee par le developpement de l'Energie atomique ont demande au Commissariat a l'Energie atomique de former des ingenieurs capables d'etudier des projets de piles et de diriger leur construction. 2- Recrutement et Droits d'inscription. Les demandes d'inscription ont toujours depasse les possibilites. Cette annee, les cours sont suivis par 74 eleves permanents, dont 20 etrangers, et une centaine d'auditeurs libres. Tous les elevont deja ingenieurs ou nantis de grades universitaires eleves. Droit d'inscription: 250 000 F pour les eleves, 125 000 F pour les auditeurs. 3- Organisation de l'Enseignement. II comprend deux options: physique et chimie et dans chaque option: une centaine de conferences, une trentaine de travaux pratiques, des stages dans les services, l'etude d'un projet de reacteur par un groupe de 4 ou 5 eleves. L'ensemble occupe l'annee universitaire du 1 novembre au 14 juillet. 4- Sanction. Un examen final combinant les notes de deux epreuves theoriques, des travaux pratiques, du stage, et du projet conduit a un diplome d'ingenieur en genie atomique. Il n'est pas cree en realite de nouveaux ingenieurs; une mention nouvelle est seulement ajoutee a un diplome deja acquis. Les resultats ont toujours ete excellents. Le pourcentage des echecs est tres faible. 5- Placement des Diplomes. Ils reviennent tous dans leurs industries d'origine qui ont paye leurs salaires et les droits d'inscription en se privant de leurs services pendant les neuf mois de duree des cours. 6- Creations analogues. Un cours analogue a ete cree au Centre d'Etudes Nucleaires de Grenoble. Tandis que celui de SACLAY s'adresse plus specialement aux ingenieurs deja en fonctions, celui de Grenoble est, en principe, destine aux jeunes ingenieurs sortant des ecoles. 7- Conclusion. L

  17. Tritium enrichment by thermal diffusion. I. Calculation of an installation for measuring natural tritium; Enrichissement du tritium par diffusion thermique. - I. Calcul d'une installation destinee a la mesure du tritium naturel

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M.; Ravoire, J. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The natural content of tritium is so low that its measurement generally requires a preliminary enrichment. The thermal diffusion on hydrogen is studied as an enrichment method. The installation studied comprises two stages of columns of the hot-wire type, together with a device for transferring the tritium from the water sample into the hydrogen in the columns using catalytic exchange. A complete mathematical treatment for the operation of such a unit has been made and programmed for the IBM 7094 computer. An optimization has been effected by means of this program. It is shown that for similar performances, less hydrogen is retained in the case of hot-wire type columns than in the case of columns composed of concentric tubes. (authors) [French] La teneur naturelle du tritium est si faible que sa mesure demande generalement un enrichissement prealable. On etudie la diffusion thermique sur l'hydrogene comme moyen d'enrichissement. L'installation que l'on etudie comprend deux etages de colonnes du type fil chaud, et un dispositif de transfert du tritium de l'echantillon d'eau dans l'hydrogene des colonnes par echange catalytique. Un traitement mathematique complet du fonctionnement d'un tel ensemble a ete etabli et programme sur machine IBM 7094. Une optimisation a ete faite a l'aide du programme. On montre egalement qu'a performances egales, la retenue d'hydrogene est plus faible dans le cas des colonnes du type fil chaud que dans le cas des colonnes du type tubes concentriques. (auteurs)

  18. Specific heat measurements on metals up to their melting point; Mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion

    Energy Technology Data Exchange (ETDEWEB)

    Affortit, Ch [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-07-15

    We have built an apparatus to measure the specific heat of metal up to the melting point. The method is the pulse-heating method, where the specimen is heated very rapidly (1/10 s) from room temperature to the melting point by a very intense d.c. current (1000 A). The simultaneous measurements of intensity, voltage and temperature in the specimen allows a calculation of the specific heat. We have obtained good results for niobium, tungsten, tantalum and uranium. The accuracy is around 3 to 5 per cent and allows a measurement of the heat of formation of vacancies near the melting temperature. (author) [French] Nous avons construit un appareil permettant la mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion. La methode utilisee est la methode dite de chauffage instantane, L'echantillon est echauffe tres rapidement (1/10 s) de la temperature ambiante a la temperature de fusion par le passage d'un courant tres intense ({approx} 1000 A). L'enregistrement simultane de l'intensite du courant, de la difference de potentiel aux bornes de l'echantillon et de la temperature, permet de calculer la chaleur specifique. Nous avons obtenu de bons resultats pour le niobium, le tungstene tantale et l'uranium. La precision de la methode est de l'ordre de 3 a 5 pour cent et permet une mesure de la chaleur de formation des lacunes au voisinage de la fusion. (auteur)

  19. Contribution to the study of a method for measuring continuously the isotopic effect. The search for an isotopic effect during the reduction of cuprous oxide by a {sup 12}CO - {sup 14}CO mixture (1962); Contribution a l'etude d'une methode de mesure continue de l'effet isotopique. Recherche d'un effet isotopique dans la reduction de l'oxyde cuivreux par le melange {sup 12}CO - {sup 14}CO (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Richard, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-15

    The determination of an isotopic effect between the two reactions: {sup 12}CO + Cu{sub 2}O {yields} {sup 12}CO{sub 2} + 2 Cu 'light' reaction {sup 14}CO + Cu{sub 2}O {yields} {sup 14}C{sub O}2 + 2 Cu 'heavy' reaction is possible if the respective kinetics are known. The condensation, during the reaction, of the carbon dioxide formed, and the measurement as a function of time of the residual carbon monoxide pressure, makes it possible to deduce, uninterruptedly, the 'light' reaction kinetics. The 'heavy' reaction kinetics are obtained by measuring continuously, in situ, the radioactivity of the residual reactant gas as a function of the time. The apparatus used for this is a plastic scintillator counter. A calibration curve of the measured radioactivity as a function of the reactant gas pressure in the absence of reaction makes it possible to compare the kinetics of the 'light' and 'heavy' reactions. The reaction temperature is chosen such that the reaction rate is sufficiently slow, so that the variation of the radioactivity during unit counting time is negligible. (author) [French] La determination d'un effet isotopique entre les deux reactions: {sup 12}CO + Cu{sub 2}O {yields} {sup 12}CO{sub 2} + 2 Cu reaction 'legere' {sup 14}CO + Cu{sub 2}O {yields} {sup 14}C{sub O}2 + 2 Cu reaction 'lourde' est rendue possible par la connaissance de leurs cinetiques respectives. La condensation, au cours de la reaction, du gaz carbonique forme et la mesure en fonction du temps de la pression de l'oxyde de carbone residuel, permet d'obtenir, de facon continue, la cinetique de la reaction 'legere'. La cinetique de la reaction lourde est determinee par la mesure continue, in situ, du taux de radioactivite du reactif gazeux residuel en fonction du temps. Le dispositif employe dans ce but est un compteur a scintillateur plastique. Une courbe d'etalonnage, du taux mesure de radioactivite en fonction de la pression du gaz reactif, en l'absence de reaction, permet de comparer les

  20. Une méthode pour estimer l’interception du rayonnement par un couvert bas : application au colza avant montaison

    Directory of Open Access Journals (Sweden)

    Denoroy Pascal

    2002-01-01

    introduire dans l’équation 2 un paramètre représentant le taux de couverture du sol. Si l’estimation par mesure directe de epsiloni et donc l’estimation de k sont assez simples, au moins dans le principe pour un couvert développé en hauteur (colza après montaison [3], une telle mesure devient beaucoup plus complexe dans le cas d’un couvert discontinu et bas. Dans ce milieu hétérogène (et souvent dans des conditions hivernales sévères, une distribution représentative des capteurs de rayonnement est difficile, les risques de perturbation de la mesure (salissure des capteurs, déréglages sont élevés. Plusieurs études ont déjà traité de epsiloni et k dans le cas du colza [3-7]. Elles sont fondées sur des mesures d’interception du rayonnement et concernent des couverts fermés, après montaison. Une autre approche consiste à effectuer un calcul précis de PARi avec des modèles détaillés utilisant une description complète des paramètres (géométriques et radiatifs du feuillage, et du rayonnement incident [8]. Mais les données nécessaires sont alors nombreuses, complexes à obtenir et donc généralement non disponibles en expérimentation. Pour répondre aux besoins de calcul de l’interception du rayonnement dans les phases d’installation du colza, cet article présente une méthode permettant de calculer epsiloni en tenant compte des principales caractéristiques de la morphologie du couvert et du régime radiatif auquel ce dernier est soumis. Les données nécessaires sont limitées : l’indice foliaire, les taux de couverture du sol (deux définitions, la latitude du lieu considéré, la date et le rayonnement incident quotidien. Ce calcul permet une estimation du coefficient moyen d’extinction k (équation 2. On verra que k peut être corrélé à l’IF, la période de l’année et la latitude du lieu, ce qui permet de proposer une estimation simple de k et donc un calcul simplifié de epsiloni, adapté au cas des faibles IF

  1. Lifetime measurement in Proserpine by reactivity modulation (1960); Mesure du temps de vie dans proserpine par modulation de la reactivite (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Clouet d' Orval, C; Tachon, J; Bertrand, J; Lecoustey, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The measurement method consists in varying the neutron flux periodically by means of an oscillator with cadmium sectors. From the signal received on a detector the lifetime {tau} can be determined; for various velocities {omega}, we have: (n/{delta}n){sup 2} = ({beta}{sub eff}/{delta}k){sup 2} + ({tau}/{delta}k){sup 2}{omega}{sup 2}. Various corrections are involved, in particular the calculation of the rates of different harmonics in the oscillator signal. (author) [French] La methode de mesure consiste a faire varier periodiquement le flux de neutrons au moyen d'un oscillateur a secteurs de cadmium. Le signal recu sur un detecteur permet la determination du temps de vie {tau}; pour differentes vitesses {omega}, on a: (n/{delta}n){sup 2} = ({beta}{sub eff}/{delta}k){sup 2} + ({tau}/{delta}k){sup 2}{omega}{sup 2}. Differentes corrections interviennent, en particulier, le calcul du taux des differents harmoniques dans le signal de l'oscillateur. (auteur)

  2. Physics experiments in graphite lattices (1962); Experiences sur les reseaux a graphite (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Bacher, P; Cogne, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    A review is made of the various experimental methods used to determine the physics of graphite, natural uranium lattices: integral lattice experiments; both absolute and differential, effective cross section measurements, both by activation methods and by analysis of irradiated fuels, fine structure measurements. A number of experimental results are also given. (authors) [French] On decrit les differentes methodes experimentales utilisees pour determiner les parametres physiques de reseaux a uranium-graphite. Il s'agit d'experiences globales: mesures absolues et relatives de laplaciens, mesures de sections efficaces effectives par activation et par analyses de combustibles irradies, mesures de structures fines. Un certain nombre de resultats experimentaux sont communiques. (auteurs)

  3. Systematic study of the use of electrical fields for improving heat exchange in boiling liquids; Etude systematique de l'utilisation de champs electriques pour l'amelioration des echanges thermiques dans des liquides bouillants

    Energy Technology Data Exchange (ETDEWEB)

    Bochirol, L; Bonjour, E; Lagnier, R; Verdier, J; Weil, L [Commissariat a l' Energie Atomique, Grenoble (France).Centre d' Etudes Nucleaires

    1961-07-01

    We have studied, at the boiling point, for liquids with various electrical properties (hexane, benzene, trichloroethylene, demineralized water, acetone, methyl-ethyl-ketone, etc...) the effect of the application of electric fields on the exchange coefficients and on the maximum dissipative powers before calefaction. We have given the mechanism of the significant improvements obtained (multiplication by a factor of 2 to 10): - in the natural convection zone by showing the role played by the dielectric properties of the liquids under study; - in the zone of nuclear boiling by analysis of the forces acting on the boiling nuclei. Finally we give some experimental results concerning measurements made under pressure until local boiling occurred: they show the possibility of some interesting applications of the method. (author) [French] On a etudie, a l'ebullition, sur des liquides de caracteristiques electriques diverses (hexane, benzene, trichlorethylene, eau demineralisee, acetone, methylethylcetone, etc...) les effets de l'application de champs electriques sur les coefficients d'echanges et les puissances maximales dissipables avant calefaction. On a precise le mecanisme des ameliorations importantes obtenues (multiplication par un facteur 2 a 10): - dans la zone de convection naturelle en mettant en evidence le role des caracteristiques dielectriques des liquides etudies; - dans la zone d'ebullition nucleaire par analyse des forces mises en jeu sur les noyaux d'ebullition. On donne enfin des resultats experimentaux sur des mesures effectuees sous pression jusqu'a l'ebullition locale: ils illustrent des possibilites d'applications interessantes du procede. (auteur)

  4. Évaluation des services rendus par les écosystèmes  en France

    Directory of Open Access Journals (Sweden)

    Philippe Blancher

    2011-12-01

    Full Text Available Cet article rend compte de la méthode d’évaluation des services écosystémiques appliquée au territoire français dans le cadre d’une approche exploratoire. S’inscrivant dans le sillage du ‘‘Millennium Ecosystem Assessment’’ (MA lancé par l’ONU, l’application de la démarche du MA à un territoire donné a conduit à l’élaboration de nouveaux outils d’analyse et de mesure des interactions entre nature et activités humaines à plusieurs échelles territoriales, à travers une projection cartographique des écosystèmes sur l’ensemble du territoire, un recensement des services rendus par les écosystèmes en France et une méthodologie pour leur quantification.This article introduces a method for the assessment of ecosystem services on the French territory. Following the U.N.-initiated Millennium Ecosystem Assessment framework, the implementation of an ecosystem assessment on a specific territory led to the conception of new tools for the analysis and the measurement of interactions between nature and human activities at different territorial scales, through the mapping of ecosystems, an identification of ecosystem services on the French territory and a methodology for their quantification.

  5. Douleurs induites par les soins: la réalité au Centre Hospitalier Universitaire de Befelatanana Antananarivo, Madagascar

    Science.gov (United States)

    Mahavivola, Ernestho-Ghoud Indretsy; Olivah, Razanaparany Miarisoa Mireille; Mihary, Dodo; Hendriniaina, Rakotoharivelo; Lalao, Randriamboavonjy Rado; Henintsoa, Rakotonirainy Oliva; Fahafahantsoa, Rapelanoro Rabenja

    2014-01-01

    La douleur induite par les soins correspond à la douleur survenant lors des actes à visé diagnostique et/ou thérapeutique. A notre connaissance, nous n'avons pas encore des données disponibles pour les douleurs induites par les soins à l'Hôpital de Befelatanana. Nos objectifs étaient de décrire le profil épidémiologique de la douleur induite par les soins, d'identifier les principaux facteurs influençant sur l'intensité de la douleur et leurs retentissements chez les patients. Il s'agissait d'une étude rétrospective, transversale type un jour donné menée dans les douze services de Médecines au Centre Hospitalier Universitaire de Befelatanana en Novembre 2013. Cent deux patients ont été retenus dans l’étude et trois cent vingt trois actes douloureux étaient enregistrés. La fréquence de la douleur induite par les soins était de 69,86%. Le genre féminin prédominait dans 52% des cas (n = 53) avec un sex-ratio à 0,92. L’âge moyen était de 46 ans. Les ponctions vasculaires étaient l'acte prédominant dans 49,54% (n = 109) des cas. Les infirmiers réalisaient les soins dans 47,05% (n = 48) des cas. L'information verbale était la mesure préventive utilisée dans 57,84% des cas (n = 59). Le transport par marche à pied et au dos représentait 16,67% des cas (n = 17). Les patients naïfs des gestes étaient plus anxieux. Ces patients gardaient de mauvais souvenir dans 64,71% des cas (n = 66). La fréquence de douleur induite par les soins était trop élevée. Un effort important est nécessaire pour réduire la douleur induite par les soins PMID:25932071

  6. Les principes distributifs des mesures d’insertion des jeunes à l’épreuve du longitudinal Youth integration measures and their criteria tested by a longitudinal approach

    Directory of Open Access Journals (Sweden)

    Léa Lima

    2009-07-01

    Full Text Available La sélection des bénéficiaires des mesures d’action sociale relève d’un problème éthique qui fait l’objet d’une intense activité cognitive et normative de la part d’acteurs publics outillés par l’expertise. Or, l’examen historique des principes distributifs mobilisés dans les politiques d’insertion des jeunes donne à voir la reformulation des référentiels de l’action publique dans un cadre longitudinal ainsi que ses effets sur les présupposés éthiques des politiques. Le principe de discrimination positive consistant à redistribuer les chances d’insertion en faveur des jeunes les moins formés a été énoncé au sein d’une représentation instantanéiste de l’insertion des jeunes. Il perd de sa validité avec l’institutionnalisation des trajectoires. L’éthique de l’accompagnement du parcours qui devient dominante dans les années 1990 perd de vue les inégalités entre groupes de niveau de formation au profit d’une démarche d’organisation de carrières ascendantes permises par les mesures d’action sociale disponibles.Targeting social programs is an ethical problem for administrators. Therefore, they develop an intense cognitive and normative activity with the help of experts in economics. The history of how funds are allocated in support of youth integration policies shows the longitudinal reframing of public policy and its impact on ethical principles. The principle of affirmative action consisting in redistributing offers among less qualified youth has been formulated according to a static representation of youth integration. It loses its validity with the institutionalization of individual itineraries. The ethic of pathway support that became dominant in the 1990s lost sight of the inequality between groups levels of qualification no longer appeared relevant and gave way to the organization of upwardly mobile careers made possible by the social programs at hand.

  7. The origin of cholesterol in chyle demonstrated by nuclear indicator methods; Origines du cholesterol du chyle mises en evidence par la methode des indicateurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, M

    1962-07-01

    In order to obtain information about the mechanism of the intestinal absorption of cholesterol, rats having a lymphatic abdominal fistula are used. The animals receive either 4-{sup 14}C- cholesterol subcutaneously or orally, or the 1-{sup 14}C acetate. The study of the specific radio-activities of the cholesterol in chyle, in serum, in the lining, and in the intestinal contents makes it possible to define the roles played by the transfer cholesterol from the serum, by the cholesterol synthesised intestinally, and by the absorption cholesterol, in the formations of the lymph and of the chylomicrons. A new theory is proposed for the mechanism of cholesterol absorption. (author) [French] Pour obtenir des renseignements concernant le mecanisme de l'absorption intestinale du cholesterol, on utilise des rats porteurs d'une fistule lymphatique abdominale. Les animaux recoivent soit du cholesterol 4-{sup 14}C par voie sous-cutanee ou par voie orale, soit de l'acetate 1-{sup 14}C. L'etude des radioactivites specifiques du cholesterol du chyle, du serum, de la paroi et du contenu intestinal permet de preciser les roles joues par le cholesterol de transfert d'origine serique, par le cholesterol de synthese intestinale et par le cholesterol d'absorption, dans la formation de la lymphe et des chylomicrons. Une theorie nouvelle concernant le mecanisme de l'absorption du cholesterol est proposee. (auteur)

  8. Nuclear biological studies in France; Les etudes de biologie nucleaires en France

    Energy Technology Data Exchange (ETDEWEB)

    Coursaget, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    On the occasion of a colloquium on radiobiological research programmes, a number of documents dealing with French accomplishments and projects in this field were collected together. We felt that it would be useful to assemble these papers in one report; although they are brief and leave gaps to be filled in, they provide certain data, give an overall view of the situation, and can also suggest a rough plan for the general policy to adopt in the field of 'nuclear' biological research; i.e. research based on the nuclear tracer method or devoted to the action of ionising radiations. (author) [French] Un colloque sur les programmes de recherche en radiobiologie nous a donne l'occasion de reunir des documents sur les realisations et les projets francais dans ce domaine. Il nous a semble utile de reunir en un rapport l'ensemble de ces documents, qui, malgre leur brievete et malgre les lacunes qu'ils comportent, donnent un certain nombre d'informations, permettent une vue d'ensemble et peuvent dessiner aussi l'ebauche d'une politique coherente en matiere de recherches biologiques 'nucleaires', c'est-a-dire de recherches basees sur la methode des indicateurs nucleaires ou consacrees a l'action des rayonnements ionisants. (auteur)

  9. Measurement of the activity of beta emitting gases using an ionisation chamber; Mesure de l'activite des gaz emetteurs beta au moyen d'une chambre d'ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Lebouleux, P [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    An ionization chamber was developed for measuring directly the activity of a {beta}-emitting gas whatever the gas may be. The following two parameters are defined and determined: p, the average specific ionization produced by a {beta} disintegration, and i, the average {beta} path in the chamber. It was shown, during the determination of i, that the {beta} particles are reflected on the walls of the ionization chamber when the latter are made of a high atomic number material. It was possible to eliminate this effect by constructing an electrode chamber made of graphite. With this chamber a direct measurement can be made of the activity of a gaseous {beta} emitter with a precision of about {+-}10%. Some applications are given of the graphite electrode chamber (calibration of the chambers built industrially and determination of the activation cross section of a gaseous emitter). It was possible to determine the activation cross section of {sup 134}Xe; a value of 0.18 {+-} 0.03 barn was found. (author) [French] Le but de l'etude est de realiser une chambre d'ionisation permettant d'effectuer une mesure directe de l'activite d'un gaz emetteur {beta} quel que soit l'emetteur considere. On definit et l'on determine les deux parametres suivants: p: ionisation specifique moyenne produite par une desintegration {beta}. La determination est effectuee par une methode graphique, i: moyenne des parcours des {beta} dans la chambre. La determination est effectuee experimentalement par introduction dans la chambre d'un gaz radioactif dont on peut calculer l'activite. On a mis en evidence, au cours de la determination de i, la reflexion des particules {beta} sur les parois des chambres d'ionisation lorsque celles-ci sont constituees d'un materiau de numero atomique eleve. La construction d'une chambre a electrodes de graphite nous a permis d'eliminer ce phenomene. Avec cette chambre, on effectue une mesure directe de l'activite d'un emetteur {beta} gazeux avec une precision de l

  10. Study and development of an optical method for the measurement of convection coefficients; Etude et developpement d'une methode optique pour la mesure du coefficient de convection

    Energy Technology Data Exchange (ETDEWEB)

    Crowther, David J.

    1990-03-06

    This research thesis addresses the field of fluid-wall thermal exchanges in which the notion of exchange coefficient is notably useful to design, size and optimise devices. A first part reports a bibliographical study which gives an overview of solutions envisaged to determine the convection coefficient in permanent regime with the use of flow sensors, as well as in transient regime. Then, the author reports the development of an unsteady method which is based on the analysis of the cooling kinetics of the front face of a convecting wall, after a unique energetic perturbation (an infinitely brief pulse, or a finite duration energy step). This method is applied to the general case (wall with finite thickness) and to the case of a semi-infinite wall which is typical of materials which are weak thermal conductors. This is extended to the case of good thermal conductors by considering a thermally thin wall. After a detailed description of the experimental bench, above-mentioned solutions are applied to insulating and good thermal conducting materials. In order to validate results of an analysis in transient regime, they are compared with measurements performed in permanent regime with a flow-metering technique. The study of the principle of the dissipation-based flow sensor, and its operation are reported. Experimental results are presented for both methods (pulse and flow sensor), and compared in order to highlight the interest of the unsteady method [French] Difficile a mesurer, le coefficient de convection reste cependant une grandeur necessaire au calcul et a l'optimisation de tout systeme thermique. L'amelioration des capteurs thermiques permet aujourd'hui de concevoir une methode optique, utilisable a distance, et non destructive. Nous proposons dans ce but, un procede de mesure en regime transitoire base sur la radiometrie photothermique impulsionnelle. L'analyse du regime de relaxation d'une paroi, apres une brusque elevation de temperature, permet de remonter

  11. Optimal sizes and siting of nuclear fuel reprocessing plants; Tailles et localisations optimales des usines de retraitement des combustibles nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Thiriet, L; Deledicq, A [Commissariat a l' Energie Atomique, Siege (France). Centre d' Etudes Nucleaires

    1967-07-01

    The expansion of a nuclear economy entails the development of fuel process and reprocessing plant programmes. The model proposed makes it possible to select the size, the site and the start-up schedule of the plants in such a way as to minimize the total freight and reprocessing costs. As an illustration, we have approached the problem of burnt natural uranium processing plants related to natural uranium-graphite as nuclear power stations. The sites and annual output of the reactors, the possible plant sites and cost functions (freight and reprocessing) are supposed to be known. The method consists in first approaching the process plant problem as a Dynamic Programming problem, increasing programme slices (total reactor output) being explored sequentially. When the quantities of burnt natural uranium to be reprocessed are fixed, the minimization of the transport cost is then also carried out as a dynamic programming problem. The neighbourhood of the optimum process cost is explored in order to find the minimum summation of a suboptimal processing cost and corresponding optimal transport cost. As the reprocessing problem can be represented on a sequential graph, in order to compute the sub-optima, we developed and used a 'reflexion algorithm'. The method can be interpreted as a general mechanism for determining the optimum when to a sequential dynamic problem (for example an equipment programme) is added a complementary problem (transport, for instance). It also makes it possible to estimate the economic losses which result from the choice of a non optimal policy for other than economic reasons. (author) [French] L'expansion de l'economie nucleaire se traduit par un developpement des programmes d'usines d'elaboration et de retraitement des combustibles. Le modele propose permet de choisir la taille, la localisation et la cadence de mise en service des usines de maniere a minimiser le total des frais de transport et de retraitement. A titre d'exemple nous avons

  12. La mesure comme représentation de l’objet

    Directory of Open Access Journals (Sweden)

    Danielle Laberge

    2011-04-01

    Full Text Available Adoptant une perspective d’interpénétration des méthodes et nous centrant sur le rôle des actes méthodiques dans la production des connaissances, nous procédons à l’examen de la place et du rôle de l’interprétation dans le processus de la mesure. Partant de la définition d’Abraham Kaplan selon laquelle « la mesure est l’assignation de nombres à des objets, des événements ou des situations à partir d’un système de règles définissant des propriétés pouvant être quantifiées » (Kaplan, 1964, nous considérons la mesure comme une activité méthodique de recherche constituée d’un ensemble d’actes interprétatifs distincts, mis en œuvre à des moments divers du processus de recherche. Nous montrons que la mesure est susceptible à la fois de réduire la complexité et de la restaurer. La mesure ne peut être limitée à sa dimension quantitative. Elle se construit dans l’interrelation permanente avec les autres actes de connaissance.Measurement process as object’s representation. Analysis and interpretationIn this article we examine the status and the role of interpretation in the measurement process, from the point of view of mixed methods. Starting with Abraham Kaplan’s definition of “measurement as the assignment of numbers to objects (or events or situations in accord with some rule defining properties that can be quantified”, we state that measurement is produced through a set of different interpretations at various moments during the research process. It cannot be seen only as a reduction of complexity and a quantification of reality since it is also a way of restoring complexity and quality. Measurement must be understood in relation with all the other knowledge operations.La medida como objeto de representaciones. Análisis e interpretaciónEn este artículo examínanos el estatuto y el papel de los métodos de medida desde el punto de vista de lo que constituye un acto metódico. A partir

  13. Cooperation in the Event of Nuclear Accidents; Cooperation en Matiere d'Accidents Nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Bresson, G. [CEA, Centre d' etudes nucleaires, de Fontenay-aux-Roses (France)

    1969-10-15

    This paper is concerned only with the action to be taken in respect of an individual directly affected by an accident and not with the more general measures relating to the population as a whole. Keeping the same sequence of ideas, the paper deals with nuclear establishments and cites criteria for classifying them; hence only the relationship between the establishment and the hospital, and between the radiation protection experts and medical personnel, is discussed. The complex organization of emergency measures, reception of the victim of the accident, and the treatment possibly required should be based on standard practice and published material, both national and international, allowance being made for the characteristics of each sector. A ''flexible'' plan of co-ordination is given as an illustration. Action must be taken in such cases at the site of the accident, inside and outside the establishment, and above all at the hospital. All categories of persons are involved in the process, i.e. fellow-workers, management, specialized services, and medical personnel, each with their own part to play. The manpower and equipment brought into service therefore vary, and depend upon the internal and external relations maintained by the establishment. The measures envisaged should provide for the transport, reception and treatment of those involved in the accident. An existing organization of this kind is described as an illustration. Finally, no action can be of value without full knowledge of the facts and thorough training of the personnel. Some clearly defined ideas on the.subject are considered under this heading. (author) [French] Le memoire ne traite que de la conduite a tenir envers un accidente et non du probleme, plus general, des mesures relatives a une population. Dans le meme ordre d'idees, l'etude porte sur les etablissements nucleaires et leurs criteres de classement; il ne s'agit donc que des liaisons entre retablissement et l'hopital et entre les

  14. Corrosion by cooling gases in nuclear reactors; la corrosion par les gaz caloporteurs dans les reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Darras, R. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre de Saclay, Section d' etude de la corrosion par gaz et metaux liquides (France)

    1960-07-01

    This article begins with a review of the various materials which can be used and the cooling gases in which they may be heated, emphasis being placed on the importance of reaching temperatures as high as possible. This is followed by a few general remarks on the dry oxidation of metals and alloys, particularly with regard to diffusion phenomena and their various possible mechanisms, and also the methods of investigation employed. Finally, the behaviour of the chief nuclear materials heated in the various gases is studied successively. Materials used for fuel (metallic uranium, uranium oxide, carbides and silicides), canning materials (magnesium, aluminium, zirconium, beryllium, stainless and refractory steels), structural materials (ordinary or slightly alloyed steels), and finally moderators (graphite, beryllium oxide) are deal with in this way. This account is backed up both by the results obtained at the CEA and by work published outside or abroad up to the present day. In conclusion, every effort has been made to direct future research on the basis of the foregoing. Reprint of a paper published in Industries Atomiques - no. 9/10, 1959, p. 3-23 [French] Dans cet article, on passe tout d'abord en revue les divers materiaux utilisables et les gaz de refroidissement dans lesquels ils peuvent etre chauffes, en insistant sur l'interet d'atteindre des temperatures aussi elevees que possible. On rappelle ensuite quelques generalites sur l'oxydation seche des metaux et alliages, notamment en ce qui concerne les phenomenes de diffusion et leurs divers mecanismes possibles ainsi que les methodes d'etude. Enfin, le comportement des principaux materiaux nucleaires chauffes dans les divers gaz est etudie successivement. On traita ainsi des materiaux combustibles (uranium metallique, oxyde, carbures et siliciures d'uranium), des materiaux de gainage (magnesium, aluminium, zirconium, beryllium, aciers inoxydables et refractaires), des materiaux de structure (aciers ordinaires

  15. Automatic measuring device for atomic oxygen concentrations (1962); Dispositif de mesure automatique de concentrations d'oxygene atomique (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Deiss, M; Mercier, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Within the framework of the activities of the Autonomous Reactor Electronics Section we have developed a device, which renders automatic one type of measurement carried out in the Physical Chemistry Department at the Saclay Research Centre. We define here: - the physico-chemical principle of the apparatus which is adapted to the measurement of atomic oxygen concentrations; - the physical principle of the automatic measurement; - the properties, performance, constitution, use and maintenance of the automatic measurement device. It is concluded that the principle of the automatic device, whose tests have confirmed the estimation of the theoretical performance, could usefully be adapted to other types of measurement. (authors) [French] Dans le cadre des activites de la Section Autonome d'Electronique des Reacteurs, il a ete realise et mis au point un dispositif permettant de rendre automatique un type de mesures effectuees au Departement de Physico-Chimie du C.E.N. SACLAY. On definit ici: - le principe physico-chimique de l'appareillage, adapte a la mesure de concentrations de l'oxygene atomique; - le principe physique de la mesure automatique; - les qualites, performances, constitution, utilisation, et maintenance du dispositif de mesure automatique. Il est porte en conclusion, que le principe du dispositif automatique realise, dont les essais ont sensiblement confirme l'evaluation des performances theoriques, pourrait etre utilement adapte a d'autres types de mesures courantes. (auteurs)

  16. Measurement of {pi}{sup {+-}} p forward elastic differential cross sections at 410 and 490 MeV; Mesures des sections efficaces differentielles {pi}{sup {+-}} p a 410 MeV et 490 MeV vers l'avant

    Energy Technology Data Exchange (ETDEWEB)

    Banner, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-01-01

    Measurements of the {pi}{sup {+-}} p forward elastic differential cross sections were performed with a missing mass spectrometer using spark chambers. Photographs were automatically scanned. Phase shift analysis of experimental results leads to three solutions. Experiments are indicated which ought to permit overcoming ambiguity. (author) [French] Des mesures de sections efficaces differentielles elastiques {pi}{sup {+-}} p vers l'avant ont ete effectuees a l'aide d'un spectrometre de masse manquante a chambres a etincelles. Les cliches ont ete depouilles par un appareillage automatique. Les resultats experimentaux sont analyses en dephasages et conduisent a trois solutions. Des experiences sont indiquees qui devraient permettre de lever l'ambiguite. (auteur)

  17. Développement humain, développement durable et « pays en développement » : comment articuler et mesurer les différentes dimensions ?

    Directory of Open Access Journals (Sweden)

    Bruno Boidin

    2004-02-01

    Full Text Available Cet article cherche à préciser la place qu’occupent les différentes dimensions du développement durable au sein de l’analyse économique du développement, et en particulier les dimensions humaine et sociale. Ceci nous amène à considérer les relations complexes entre les différents actifs (santé, éducation, capital social…, marquées par des effets d’irréversibilité qui peuvent remettre en cause la durabilité. Se pose alors la question de la mesure du développement durable prenant en compte ces articulations entre les dimensions. Une grille d’évaluation des mesures synthétiques du développement durable est proposée et appliquée à une sélection d’indicateurs.This article seeks to specify the place of various dimensions of sustainable development within development economics, in particular human and social dimensions. This leads us to consider the complex relations between the various assets (health, education, social capital…, characterized by irreversibility effects which can jeopardize sustainability. It is therefore necessary to find a measure of sustainable development, taking into account these interactions between dimensions. We propose criteria to evaluate synthetic measurements of sustainable development, and apply them to selected indicators.

  18. Detection of Beta-Emitting Nuclides of Energy >1 Mev in Urine After an Accident by Means of Measurement of the Cerenkov Effect in a Liquid Scintillation Counting System; Detection des Radioelements Emetteurs Beta d'une Energie Superieure a 1 Mev dans l'Urine Apres un Accident, par la Mesure de l'Effet Cerenkov Avec un Ensemble de Comptage a Scintillation Liquide; 041e 0411 041d 0414 ; Deteccion en la Orina de Emisores Beta de Energia Superior a 1 Mev, Despues de un Accidente, por Medicion del Efecto Cerenkov en un Contador de Centelleador Liquido

    Energy Technology Data Exchange (ETDEWEB)

    Narrog, J. [Landesinstitut fuer Arbeitsschutz und Arbeitsmedizin, Karlsruhe, Federal Republic of Germany (Germany)

    1965-06-15

    Beta particles of energy >1 MeV in water can be measured by Cerenkov effect in liquid scintillation counters without any further preparation. Since Hoffman reported about this possibility at the Symposium held by the Gesellschaft Deutscher Chemiker (1-2 April 1964) in Karlsruhe-Leopoldshafen, experiments have been carried out in our institute to apply this method to urine. When experiments were carried out with unprepared urine, the measurements were insensitive because of the strong absorption effect. The urine must be cleared. Therefore we tried to oxidate with KMnO{sub 4} and got a clear liquid. The background was very high, because the K of the KMnO{sub 4} contains the radioactive K{sup 40}, which also emits {beta}-rays of energy > 1 MeV (1.32 MeV). We used Na MnO{sub 4} instead of KMnO{sub 4} and got better results. The background is now about 30 counts/min, the lower limit (measured with Sr{sup 90}/Y{sup 90}) about 1 pc/ml urine. If in accidents the content of radioactive K{sup 40} in urine cannot be assessed (e.g. by flame-photometry of the K-content in urine) this method gives the same sensitivity as other methods (e.g. bum and measure in a large-area proportional counting system), in this case (> 2 pc/ml). The measurement with the large-area proportional counter and additional assessment of the K{sup 40} {beta}-activity of the urine is mere sensitive and more accurate. This method is useful for a rapid measurement of large body burdens (and following excretion) of {beta}-nuclides of energy > 1 MeV, demanded by an accidental situation. With these methods we need no more than 90 min total time. (author) [French] On peut mesurer les particules beta d'une energie superieure a 1 MeV grace a l'effet Cerenkov dans des compteurs a scintillation liquide sans aucune autre preparation. Depuis que Hoffmann en a signale la possibilite a un colloque organise par la Gesellschaft Deutscher Chemiker les 1{sup er} et 2 avril 1964 a Karlsruhe-Leopoldshafen, l'auteur a

  19. Study relating to the physico-chemical behaviour of heavy water in nuclear reactors; Etudes relatives au comportement physico-chimique de l'eau lourde dans les reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Chenouard, J; Dirian, G; Roth, E; Vignet, P; Platzer, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1959-07-01

    Chemical and isotope pollution, and radiolytic decomposition are the two most important ways in which heavy water becomes degraded in nuclear reactors. Chemical pollution has led to the creation of ion exchange purification loops specially designed for reactors: the report contains a description in detail of the application of this purification method in CEA research reactors, including the analysis required, results obtained, and their interpretation. The intelligence obtained on radiolytic decomposition with the same facilities is also discussed, as well as the recombination apparatus and control equipment utilized. Finally, investigation to date in the CEA on recombination circuits for power reactors is also discussed. (author) [French] Parmi les degradations subies par l'eau lourde dans les reacteurs nucleaires, les deux plus importantes sont la pollution chimique et isotopique et la decomposition radiolytique. La pollution chimique a conduit a mettre au point pour le cas particulier des reacteurs, des circuits d'epuration par echange d'ions. On decrit ici en detail la mise en oeuvre de cette methode dans les reacteurs de recherche du CEA; les controles qu'elle necessite, les resultats obtenus et leur interpretation. En ce qui concerne la dissociation radiolytique de l'eau, les renseignements obtenus sur ces memes reacteurs sont communiques, ainsi que les details des dispositifs de recombinaison et des moyens de controle. Enfin, on fait le point des etudes poursuivies au CEA sur ces memes problemes de recombinaison dans le cas des reacteurs de puissance. (auteur)

  20. Electron multiplier for the measurement of an ion current on a mass spectrometer; Multiplicateur d'electrons pour la mesure de courant d'ions sur un spectrometre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Lohez, P; Nief, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The apparatus described is designed to measure weak ion currents received at the collector of a mass spectrometer. The report describes successively the study of electron paths in the multiplier by the method of analogy, using rubber membranes, and the practical details of construction of the apparatus. The variation with surface treatment of the secondary emission coefficient of the alloy CuBe containing 2 per cent Be, which makes up the dynodes, and the influence of the voltage on the gain per stage, are discussed. Results of tests regarding: the influence of the ion mass on the gain, the background of the instrument and the energy distribution of the impulses coming out on a high gain multiplier (q.q. 10{sup 7}) are given. Finally the performances of the multiplier are reported. 1- For a low gain (10{sup 4}), precision and reproducibility comparable to the electrometer valve, sensitivity 100 times greater, currents capable of detection 10{sup -17} Ampere. 2- For a high gain (10{sup 7}) and measurement by impulse counting, currents capable of detection 10{sup -19} Ampere. Mounting difficult to use on a mass spectrometer. (author) [French] L'appareil decrit est destine a la mesure des faibles courants d'ions re s au collecteur d'un spectrometre de masse. Le rapport decrit successivement l'etude des trajectoires des electrons dans le multiplicateur, par la methode analogique de la menbrane en caoutchouc, et la realisation pratique de l'appareil. La variation du coefficient d'emission secondaire de l'alliage CuBe a 2 pour cent de Be, constituant les dynodes suivant le traitement des surfaces, et l'influence de la tension sur le gain par etage sont discutees. Des resultats d'essais concernant: l'influence de la masse des ions sur le gain, le bruit de fond de l'appareil et la repartition en energie des impulsions de sortie sur un multiplicateur a gain eleve (q.q. 10{sup 7}) sont donnes. Enfin, sont rapportees les performances du multiplicateur. 1- pour un gain faible

  1. Contribution to the optical model study by the measurement of the reaction sections; Contribution au modele optique par la mesure de sections de reaction

    Energy Technology Data Exchange (ETDEWEB)

    Delaunay, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Excitation functions of reaction cross-section {delta}{sub R} for protons were obtained between 5 and 11 MeV, for {sup 141}Pr and {sup 150}Nd by radioactive techniques and, between 9 and 12 MeV, for Cu and Ni by the transmission method. Results were compared to the prevision of the optical model. Calculations were made to see in what part {delta}{sub R} is able to reduce the ambiguities of the optical model. (author) [French] Des fonctions d'excitation de section efficace de reaction par protons {delta}{sub R} ont ete obtenues pour {sup 141}Pr et {sup 150}Nd, entre 5 et 11 MeV, par des methodes de radioactivite et pour Cu et Ni, entre 9 et 12 MeV, par la methode de transmission. Les resultats ont ete compares aux previsions du modele optique. Des calculs ont ete faits pour voir le role que peut jouer {delta}{sub R} pour diminuer les differentes ambiguites du modele optique. (auteur)

  2. Decontamination of plutonium-contaminated surfaces; Essais de decontamination des surfaces contaminees par du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, J; Clouet d' Orval, Ch; Tachon, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measure of the neutron distribution in the core of 'Proserpine', by means of activation detectors, requires no contact between the plutonium sulfate solution and the detectors. These detectors are put into PVC or polyethylene bags. This report describes the process used to decontaminate these bags. A washing by nitric acid followed by coating with plexiglass is kept, with this process we have no contamination on the detectors. (author) [French] La mesure de la distribution de neutrons par detecteurs a activation dans le coeur de Proserpine exige de proteger ces detecteurs contre tout contact avec la solution de plutonium. Les detecteurs sont places dans des gaines en polyvinyle ou en polyethylene. Ce rapport decrit le procede utilise pour decontaminer ces gaines. On a retenu un lavage a l'acide nitrique suivi du revetement d'une meme couche de plexiglass, ce qui permet d'eviter la contamination des detecteurs. (auteur)

  3. Analytic index for nuclear physicians uses; Repertoire analytique a l'usage des physiciens nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R.; Barloutaud, R.; Bernas, R.; Bretonneau, P.; Chaminade, R.; Cohen, R.; Conjeaud, M.; Cotton, E.; Faraggi, H.; Grjebine, T.; Joffre, H.; Laboulaye, H. de; Lesueur, C.; Leveque, A.; Moreau, J.; Naggiar, V.; Papineau, L.; Prugne, P.; Schuhl, C.; Studinowski, FJ.; Netter, F.; Raievski, V.; Valladas, G. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires; Marty, N.; Renard, G. [College de France, Lab. de Chimie Nucleaire (France)

    The problem of the documentation in nuclear physics becomes constantly more complex. Every week brings its share of new publications, always more numerous and more varied. To remedy to this facts that we tried, in the service of Nuclear Physics of the CEA, to give to the documentation a character of a collective and systematized work. The present report covers the literature appeared between first January 1950 and first July 1951. (Volume 1: CEA report number 120; Volume 2: CEA report number 184). (M.B.) [French] Le probleme de la documentation en physique nucleaire devient sans cesse plus complexe. Chaque semaine apporte son lot de publications, toujours plus nombreuses et plus diversifiees. C'est pour essayer de porter remede a cet etat de choses que nous avons essaye, au service de Physique Nucleaire du C.E.A., de donner a la documentation le caractere d'un travail collectif systematise. Le present rapport couvre la litterature parue entre le premier Janvier 1950 et le premier Juillet 1951. (Tome 1: Rapport CEA numero 120; Tome 2: Rapport CEA numero 184). (M.B.)

  4. Thermal energy of nuclear origin produced in non-fissile materials (1962); Energie calorifique d'origine nucleaire degagee dans les materiaux non fissiles (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Naudet, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Millies, P; Berger, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    A first part is devoted to the description of the interaction phenomena between elementary particles and material that may be observed during the irradiation process in a nuclear reactor: nuclear reactions due to neutrons, production of gamma rays and absorption of those gamma rays through various processes. In a second part the phenomena producing calorific energy in irradiated material are quantitatively examined. In the third part results are summed up in a formulary. The fourth part presents tables and figures giving to the reader all the numerical values necessary for practical calculations. (authors) [French] Une premiere partie est consacree a l'examen des principaux phenomenes d'interaction des particules avec la matiere qui interviennent lors d'une irradiation dans un reacteur: reactions nucleaires dues aux neutrons, production des rayons gamma et absorption de ces derniers par les divers processus. Une deuxieme partie etudie quantitativement les phenomenes qui conduisent a l'apparition d'energie calorifique dans le materiau irradie. En troisieme partie, un formulaire resume les resultats etablis. Dans une quatrieme partie, des tableaux et des courbes fournissent a l'experimentateur toutes les valeurs numeriques necessaires aux calculs pratiques. (auteurs)

  5. Preliminary studies of the kinetics of a reactor by the probability method; Etude preliminaire de la cinetique d'un reacteur par la methode des probabilites

    Energy Technology Data Exchange (ETDEWEB)

    Bruna, J G; Brunet, J P; Clouet D' Orval, Ch; Caizergues, R; Verriere, Ph [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The {alpha} decay constant of prompt neutrons has been studied in the homogeneous plutonium-fueled, light-water-moderated reactor Alecto, by the probability method. In this method, the probability to count one, two,.... neutrons during a given time is measured. The value of {alpha} can be deduced from this measurement, for various subcritical states of the reactor. The experimental results were then compared with values obtained, for the same reactivities, by the pulsed neutron technique. (authors) [French] On a etudie sur Alecto, reacteur homogene au plutonium, modere a l'eau legere, la constante de decroissance {alpha} des neutrons prompts par la methode des probabilites. Celle-ci consiste a mesurer la probabilite de compter un, deux, etc..., neutrons pendant un intervalle de temps donne. On a pu en deduire la valeur de {alpha}, dans divers etats sous-critiques du reacteur. On a compare les resultats experimentaux a d'autres valeurs obtenues, aux memes reactivites, par la methode des neutrons pulses. (auteurs)

  6. Legal and Administrative Problems of Controlling the Disposal of Nuclear Wastes in the Sea; Problemes Juridiques et Administratifs Poses par le Controle de l'Elimination des Dechets Nucleaires dans la Mer; 041f 0420 041e 0414 ; Problemas Juridicos y Administrativos que Plantea el Control de la Evacuacion de Desechos Nucleares En El Mar

    Energy Technology Data Exchange (ETDEWEB)

    Hydeman, Lee M.; Berman, William H. [Atomic Energy Research Project, University of Michigan Law School (United States)

    1960-07-01

    The basic purpose of the paper is to present some approaches to multinational control of the sea disposal of nuclear wastes, considering both the type of international .control which may be appropriate and the means for accomplishing such control. First, the authors give a brief description of the kind of control which appears to be necessary in protecting public health against the hazards of the disposal of wastes in the sea. The second part consists of a general analysis of the legal problems posed by nuclear wastes. Emphasis is placed on the authority of coastal states to impose unilateral control on the disposal of wastes by other nations if such disposal might adversely affect their interests. The authors inquire into the adequacy of legal remedies as well as the possible rule of law regarding the prevention of damage from waste disposal and the apportionment of liability in the event that such damage does occur. The third part is an analysis of how other problems of control have been handled, both unilaterally and multilaterally. The final part consists of an inquiry into various means of internationally controlling the sea disposal of nuclear wastes. The role of existing international bodies in the maintenance of continuing administrative control at the international level is mentioned. (author) [French] Le but essentiel du memoire est d'exposer diverses facons d'envisager le probleme du controle multinational de l'evacuation des dechets nucleaires dans l'eau de mer, en examinant a la fois le type de controle international approprie et les moyens de le mettre en oeuvre. La premiere partie contiendra une description succincte du genre de controle qui semble necessaire pour la protection de la sante publique contre les effets de l'evacuation des dechets dans la mer. La deuxieme partie consistera en une analyse generale des problemes juridiques poses par. l'elimination des dechets nucleaires. Les auteurs traiteront particulierement du droit des Etats riverains

  7. Improvements to the properties of uranium by addition of small quantities of other metals; Ameliorations apportees a l'uranium par de faibles additions metalliques

    Energy Technology Data Exchange (ETDEWEB)

    Englander, M [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    {sup 235}. Dans les conditions optimales de fonctionnement, un meme materiau combustible doit alors fournir un minimum de 3000 MWj/t, soit 72.10{sup 6} kWh par tonne d'uranium naturel, tout en etant porte a une temperature suffisante pour jouer efficacement son role de source de chaleur (entre 350 et 550 deg. C minimum). Or d'une facon assez surprenante, les agregats polycristallins des billettes d'uranium obtenues par coulee sous vide, ou apres filage a haute temperature, se presentent comme un ensemble de grains tres grossiers, a contours dechiquetes et irreguliers, et comportent de nombreuses marques de deformation intragranulaire (macles, lignes de glissement), accompagnees de fortes sous-structures. En plus, le spectre de la dimension des grains s'etend de quelques microns a quelques millimetres, selon les plages micrographiques examinees. Sous irradiation a ces temperatures, l'uranium metallique pur en barreaux cylindriques de diametre de l'ordre du pouce, se deforme: il se produit des fissures dans la masse, des variations de dimensions longitudinales et transversales (qui se traduisent par des peaux d'orange), soit par croissances plus ou moins directionnelles, soit par deformations superficielles qui peuvent provoquer des ruptures du materiau, de sa gaine ou des fleches suffisamment importantes pour obstruer les canaux de refroidissement. Il a ete reconnu par la suite que cette instabilite, sous l'effet des contraintes thermiques d'origine nucleaire, est due a la morphologie heterogene de l'uranium et a sa structure cristalline anisotrope (U{sub {alpha}} ou U{sub {beta}}). (auteur)

  8. Criteria for Special Nuclear Materials Inventory and Control Procedures; Criteres a Suivre Pour Proceder a l'Inventaire des Matieres Nucleaires Speciales et aux Mesures de Controle; Kriterii dlya inventarizatsii spetsial'nykh yadernykh materialov i metody ucheta; Criterios a Que Deben Ajustarse los Procedimientos de Inventario y Control de los Materiales Nucleares Especiales

    Energy Technology Data Exchange (ETDEWEB)

    Kinderman, E. M.; Tarrice, R. R. [Stanford Research Institute, Menlo Park, CA (United States)

    1966-02-15

    and the total inventory of these special nuclear materials. A matrix of solutions to the management and inventory control of special nuclear materials will be presented. The multiplicity and relative effectiveness of varied techniques at key stages of the materials supply, utilization and recovery are assessed. (author) [French] L'un des plus importants problemes qui, dans le domaine nucleaire et notamment dans l'exploitation commerciale de l'energie d'origine nucleaire, se posera aux societes d'investissement, aux directeursetaux exploitants est celui du controle efficace de l'inventaire des matieres nucleaires dont la valeur depassera, d'ici 1980, 5 milliards de dollars des Etats-Unis. Comparativement a la plupart des matieres utilisees commercialement, les matieres nucleaires speciales sont couteuses; aux Etats-Unis par exemple, l'uranium enrichi a 90%, l'uranium enrichi a 3% sous forme d'hexa- fluorure et l'eau lourde coutent respectivement 10808 dollars, 254 dollars et 61,60 dollars le kilo. En outre, ces matieres sont frequemment soumises, pour des raisons de protection sanitaire et de securite, a des controles gouvernementaux speciaux sans rapport direct avec leur valeur monetaire. En depit de leur prix eleve, ces matieres sont destinees a etre utilisees en grandes quantites; par exemple, on utilisera de 50 a 75 t de combustible enrichi a 3{sup o}{r_brace}o dans un reacteur de 500 MW modere a l'eau ordinaire et 200 a 300 reacteurs de cette puissance fonctionneront vraisemblablement dans le monde en 1980. L'experience acquise a permis la mise au point et l'application de methodes speciales pour le controle commercial de grandes quantites de matieres de faible valeur comme le charbon ou le minerai de fer ou de petites quantites de matieres de grande valeur comme les metaux precieux. Tout en ayant des prix comparables a ces derniers, les matieres nucleaires speciales sont de nature differente et seront utilisees en quantites beaucoup plus importantes que les

  9. Apparatus for the measurement of the distribution of neutron flux (band and wire continuous recorders); Appareillage pour la mesure des repartitions de flux neutroniques (derouleurs a bandes et a fils)

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H; Lemerle, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The apparatus of which we describe the principles and the operation, makes it possible to know the thermal neutron flux distribution in a pile channel or along a fuel element by the measurement of the {beta} activity of continuous detectors. It is also possible thereby to show the presence of a very localised sudden discontinuity in the distribution curve. (authors) [French] Les appareils dont nous decrivons le principe et le fonctionnement, permettent de connaitre la repartition du flux de neutrons thermiques dans un canal de pile ou le long d'un element combustible, par la mesure de l'activite {beta} de detecteurs continus. Ils permettent en outre de mettre en evidence un accident brutal, tres localise, de la courbe de repartition. (auteurs)

  10. KONAN KJLmdi

    African Journals Online (AJOL)

    lara

    les folioles de la feuille de rang 10. Six mesures ont été effectuées sur chaque cultivar (une mesure par ... Sur l'inflorescence de rang 19 (écotypes Grands et hybrides) ou 24 (écotypes Nains), les paramètres suivants ... inter-jour de mesure est forte sur les deux parcelles (101 et M63). Les valeurs de PH enregistrées pour le.

  11. X-spectrographic method for plutonium detection. Application to contamination measurements in humans; Etude d'une methode de detection du plutonium par spectrographie X. Application a la mesure des contaminations sur l'homme

    Energy Technology Data Exchange (ETDEWEB)

    Trouble, Michel [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    After reviewing the radio-toxicology of plutonium 239 and conventional detection methods using its {alpha}-radiation, the author considers the measurement of the X emission spectrum of plutonium 239 using a proportional counter filled with argon under pressure. This preliminary work leads to the third part of this research involving the detailed study of the possibilities of applying thin alkali halide crystal scintillators to the detection of soft plutonium X-rays; there follows a systematic study of all the parameters liable to render the detection as sensitive as possible: movement due to the photomultiplier itself and its accessory electronic equipment, nature and size of the crystal scintillator as well as its mode of preparation, shielding against external parasitic radiation. Examples of some applications to the measurement of contamination in humans give an idea of the sensitivity of this method. (author) [French] Apres un apercu de la radiotoxicologie du plutonium 239 et des methodes classiques de detection par son rayonnement {alpha}, on etudie le spectre d'emission X du plutonium 239 avec un compteur proportionnel rempli avec de l'argon sous pression. Ce travail preliminaire permet d'aborder la troisieme partie de cette etude dans laquelle nous examinons d'une fagon approfondie les possibilites d'application des cristaux scintillateurs minces d'halogenure alcalin a la detection du rayonnement X mou du plutonium; suit une etude systematique de tous les parametres susceptibles de rendre la detection aussi sensible que possible: mouvement propre du photomultiplicateur et de l'electronique associee, nature et dimensions du cristal scintillateur ainsi que son mode de fabrication, blindage contre les rayonnements parasites exterieurs. Quelques applications a la mesure des contaminations sur l'homme permettent d'apprecier la sensibilite de cette methode. (auteur)

  12. The formation of scientists and technicians at the 'Centre d'Etudes Nucleaires' at Saclay

    International Nuclear Information System (INIS)

    Debiesse, J.

    1958-01-01

    The considerable needs in research workers and scientists which are asked by the nuclear energy obliged the Commissariat a l'Energie atomique to deal with a particular effort to increase the quantitative and qualitative formation of scientists. Most various ways have been used. 1- A National Institute of Nuclear Sciences and Nuclear Techniques was created, by a joint decree of the Prime Minister and the Minister for National Education (june 18, 1957). This Institute of Higher Teaching (250 students) indulges in the following matters: atomic engineering, quantum mechanics, theory and technic of particle accelerators, special metallurgy, radiobiology, thermic and mechanics of fluids. 2- An associated centre of the 'Conservatoire National des Arts et Metiers' was created (200 students) for technical assistants, drawers, etc. 3- In contribution with both electronic industry and Ministry of Work, the Centre d'Etudes Nucleaires contributes to an accelerated formation of technical assistants into Professional Centres. Conclusion: Training of scientists and research workers is one of the most important activities of the Centre d'Etudes Nucleaires de Saclay. Without losing its technical efficiency, it has supplied and varied means adapted to the various purposes that we shall reach. (author) [fr

  13. High-Dose Ionizing Radiation Photographic Dosimetry; Mesure, par des Methodes Photogra Phiques, de Doses Elevees de Rayonnements Ionisants; 0424 041e 0422 041e 0413 0420 0414 ; Dosimetria Fotografica de Dosis Elevadas de Radiaciones Ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J.; Bucina, I. [Institute for Research Production and Application of Radioisotopes Prague, Czechoslovakia (Czech Republic)

    1965-06-15

    pour la detection de doses elevees de rayonnements et compare les merites respectifs des films FOMA et ORWO pour la mesure des doses elevees. Des progres ont egalement ete faits dans la mesure de doses elevees de rayonnements, a savoir la methode du developpement freine, decrite plus loin, dans laquelle des substances du type nitrobenzimidazole et benzotriazole sont utilisees a des concentrations appropriees dans le revelateur. Dans le cas d'emulsions lentes a forte teneur en argent, cette technique permet de mesurer des expositions a des doses gamma (rayons X de haute energie) allant jusqu'a 10s r ou meme davantage, si l 'on ne demande pas d'evaluations precises dans la gamme allant jusqu' a 100 r. Le memoire decrit l ' effet de freinage des produits chimiques ajoutes aux revelateurs sur les emulsions rapides et lentes a fortes teneur en argent. On a demontre que dans les emulsions utilisees pour la mesure de doses elevees de rayonnements intenses et traitees dans le revelateur auquel des produits chimiques de freinage ont ete ajoutes, les effets des variations en fonction de l'energie et l ' affaiblissement de l'image latente influent sur la precision des mesures. En conclusion, le memoire decrit les erreurs de dosimetrie photographique des rayonnements intenses qui ont ete decelees par des methodes statistiques mathematiques a partir de travaux experimentaux. Il est egalement question de l'accroissement de l'erreur dans les valeurs correspondant aux noircissements faibles et intenses. Les auteurs ont tenu compte egalement des erreurs dues a l'etalonnage des appareils, aux variations en fonction de l'energie, a l'affaiblissement de l'image latente, au traitement chimique et a la mesure du noircissement. La presomption que la dose mesuree par le detecteur a film correspond a la dose a l'organisme entier constitue une erreur qui n'est pas prise en consideration. (author) [Spanish] Los autores describen un metodo fotografico de medicion de dosis de radiaciones

  14. Nuclear program of Iran. Towards de-escalation of a nuclear crisis. Advisory letter; Nucleair programma van Iran. Naar de-escalatie van een nucleaire crisis. Briefadvies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-04-15

    The Dutch government, partly at the request of the House of Representatives (Second Chamber), the AIV asked to give an opinion about the position of Iran in the region and the role of the nuclear program of Iran in the geopolitical relations, in view of the most recent developments [Dutch] De Nederlandse regering heeft, mede op verzoek van de Tweede Kamer der Staten-Generaal, de AIV gevraagd advies uit te brengen over de positie van Iran in de regio en de rol van het nucleaire programma van Iran in de geopolitieke verhoudingen hierin, mede gelet op de meest recente ontwikkelingen.

  15. Nuclear biological studies in France; Les etudes de biologie nucleaires en France

    Energy Technology Data Exchange (ETDEWEB)

    Coursaget, J. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    On the occasion of a colloquium on radiobiological research programmes, a number of documents dealing with French accomplishments and projects in this field were collected together. We felt that it would be useful to assemble these papers in one report; although they are brief and leave gaps to be filled in, they provide certain data, give an overall view of the situation, and can also suggest a rough plan for the general policy to adopt in the field of 'nuclear' biological research; i.e. research based on the nuclear tracer method or devoted to the action of ionising radiations. (author) [French] Un colloque sur les programmes de recherche en radiobiologie nous a donne l'occasion de reunir des documents sur les realisations et les projets francais dans ce domaine. Il nous a semble utile de reunir en un rapport l'ensemble de ces documents, qui, malgre leur brievete et malgre les lacunes qu'ils comportent, donnent un certain nombre d'informations, permettent une vue d'ensemble et peuvent dessiner aussi l'ebauche d'une politique coherente en matiere de recherches biologiques 'nucleaires', c'est-a-dire de recherches basees sur la methode des indicateurs nucleaires ou consacrees a l'action des rayonnements ionisants. (auteur)

  16. Study relating to the physico-chemical behaviour of heavy water in nuclear reactors; Etudes relatives au comportement physico-chimique de l'eau lourde dans les reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Chenouard, J.; Dirian, G.; Roth, E.; Vignet, P.; Platzer, R. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1959-07-01

    Chemical and isotope pollution, and radiolytic decomposition are the two most important ways in which heavy water becomes degraded in nuclear reactors. Chemical pollution has led to the creation of ion exchange purification loops specially designed for reactors: the report contains a description in detail of the application of this purification method in CEA research reactors, including the analysis required, results obtained, and their interpretation. The intelligence obtained on radiolytic decomposition with the same facilities is also discussed, as well as the recombination apparatus and control equipment utilized. Finally, investigation to date in the CEA on recombination circuits for power reactors is also discussed. (author) [French] Parmi les degradations subies par l'eau lourde dans les reacteurs nucleaires, les deux plus importantes sont la pollution chimique et isotopique et la decomposition radiolytique. La pollution chimique a conduit a mettre au point pour le cas particulier des reacteurs, des circuits d'epuration par echange d'ions. On decrit ici en detail la mise en oeuvre de cette methode dans les reacteurs de recherche du CEA; les controles qu'elle necessite, les resultats obtenus et leur interpretation. En ce qui concerne la dissociation radiolytique de l'eau, les renseignements obtenus sur ces memes reacteurs sont communiques, ainsi que les details des dispositifs de recombinaison et des moyens de controle. Enfin, on fait le point des etudes poursuivies au CEA sur ces memes problemes de recombinaison dans le cas des reacteurs de puissance. (auteur)

  17. Scattering of electromagnetic waves by an non-uniform cylindrical plasma; Diffusion coherente d'une onde electromagnetique par un cylindre de plasma inhomogene

    Energy Technology Data Exchange (ETDEWEB)

    Faugeras, P E [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires. Groupe de recherches sur la fusion controlee

    1967-07-01

    (surfaces d'onde paralleles a l'axe du cylindre). Ceci permet de relier les resultats theoriques aux diagrammes de diffraction experimentaux, et aussi d'expliquer les phenomenes, de diffraction qui faussent l'interpretation des mesures par interferometrie hyperfrequence. Ces resultats, joints a la possibilite de mesurer exactement le champ diffracte (ce que nous avons montre avec des cylindres dielectriques et metalliques) conduisent a une nouvelle methode de diagnostic d'un plasma, basee sur la diffraction. Sans limitations theoriques, cette methode est applicable la ou les methodes hyperfrequences classiques ne le sont pas (diametre du plasma inferieur a 10 longueurs d'onde).Cette methode a ete experimentee sur plasma a la pression atmospherique, avec une onde incidente de 2 mm. Le plasma est engendre par le jet laminaire d'une torche a plasma, fonctionnant avec de l'helium ou de l'argon ensemence au potassium (la densite peut ainsi varier de facon continue entre 10{sup 11} et 10{sup 15} e/cm{sup 3}). On donne egalement quelques diagrammes de diffraction par ce plasma, releves pour differents champs incidents, et interpretes par les resultats theoriques precedents. (auteur)

  18. Contribution to the microwave characterisation of superconductive materials by means of sapphire resonators; Contribution a la caracterisation hyperfrequence de materiaux supraconducteurs par des resonateurs-saphirs

    Energy Technology Data Exchange (ETDEWEB)

    Hanus, Xavier

    1993-12-06

    The objective of this research thesis is to find a compact resonant structure which would allow the residual surface impedance of superconductive samples to be simply, quickly and economically characterised. The author first explains why he decided to use a sapphire single-crystal as inner dielectric, given some performance reached by resonant structures equipped with such inner dielectrics, and given constraints adopted from the start. He explains the origin of microwave losses which appear in this type of resonant structure, i.e. respectively the surface impedance as far as metallic losses are concerned, and the sapphire dielectric loss angle for as far as dielectric losses are concerned. The experimental installation and the principle of microwave measurements are described. The performance of different possible solutions of resonant structures from starting criteria is presented. The solution of the cavity-sapphire with a TE{sub 011} resonant mode is derived [French] Le but de cette etude est de trouver une structure resonnante compacte permettant de caracteriser simplement, rapidement et economiquement l'impedance de surface residuelle d'echantillons supraconducteurs. Les contraintes de mise en oeuvre et les performances atteintes par des resonateurs avec saphirs synthetiques justifient le choix d'un tel dielectrique a faible angle de perte. L'evaluation des performances experimentales appuyee par des modelesanalytiques permet de rejeter differentes solutions. Ainsi les resonateurs fermes avec saphirs minces sont rejetes en raison des mauvais contacts metalliques. Les resonateurs ouverts avec saphirs minces et epais sont egalement rejetes, meme pour les modes de resonance en principe confines, en raison des pertes par rayonnement. La seule solution est donc d'utiliser une cavite-saphir TE{sub 011} qui offre une configuration de champs naturellement confines. Des mesures sur une premiere cavite en niobium massif ont permis de selectionner un saphir obtenu par

  19. Exposition à l’arsenic et diabète de type 2 : résultats de l’Enquête canadienne sur les mesures de la santé de 2007 à 2009

    Directory of Open Access Journals (Sweden)

    S. K. Feseke

    2015-01-01

    Full Text Available Introduction: L’arsenic inorganique et ses métabolites sont considérés comme dangereux pour la santé humaine. Même si plusieurs études ont indiqué des associations entre une faible exposition à l’arsenic et le diabète sucré aux États-Unis et au Mexique, ces associations n’ont pas été étudiées chez les Canadiens. Nous avons analysé l’association entre l’exposition à l’arsenic, mesurée par la concentration d’arsenic total dans l’urine, et la prévalence du diabète de type 2 (DT2 chez 3 151 participants adultes du cycle 1 (2007 à 2009 de l’Enquête canadienne sur les mesures de la santé (ECMS. Méthodologie: La glycémie et l’hémoglobine glycosylée ont été mesurées chez les participants. L’arsenic total a été dosé par une analyse d’urine. De plus, les participants ont répondu à un questionnaire détaillé sur leurs habitudes de vie et leurs antécédents médicaux. Nous avons analysé l’association de la concentration urinaire d’arsenic avec le DT2 et le prédiabète à l’aide d’une régression logistique multivariée ajustée pour les facteurs de confusion potentiels.Résultats: La concentration urinaire d’arsenic total était positivement associée à la prévalence de DT2 et de prédiabète : les rapports de cotes ajustés étaient respectivement de 1,81 (IC à 95% : 1,12 à 2,95 et de 2,04 (IC à 95% : 1,03 à 4,05 lorsqu’on comparait les concentrations urinaires d’arsenic les plus élevées (quatrième quartile aux plus faibles (premier quartile. L’arsenic total urinaire était également associé au taux d’hémoglobine glycosylée chez les diabétiques non traités. Conclusion: Nous avons noté des associations significatives entre l’exposition à l’arsenic et la prévalence de DT2 et de prédiabète dans la population canadienne. L’inférence causale est limitée car il s’agit d’une étude transversale exempte d’évaluation de l’exposition à long terme.

  20. French achievements in the field of nuclear electronics; Realisations francaises dans le domaine de l'electronique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Doireau, M; Fabre, R; Guillon, H; Guyot, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Nuclear electronic equipment used by the french Atomic Energy Commission has been developed, with an increasing participation of the radioelectric industry (manufacture under AEC license, contracts for prototypes). The equipment for general use has been standardized and satis the technical specification sheets in which are specified more particularly, the conditions for construction, the choice of the spare parts and the conditions for acceptance by the french AEC at factory. The electronic equipment is classified in nine classes, and a brief description of the principal instruments is given in each class. The reliability of the equipment in use is satisfactory, as it is shown by the mean frequency of faults per 1000 hours operation. (author)Fren. [French] L'appareillage d'electronique nucleaire utilise au Commissariat a l'Energie atomique fran is a ete developpe en demandant un concours de plus en plus important a l'industrie radioelectrique (fabrications sous licence CEA, marches de prototypes, etc...). Le materiel d'emploi courant a ete standardise et repond aux specifications de cahiers des charges ou sont precises en particulier les conditions de realisation du materiel, le choix des pieces detachees et les conditions de recette en usine. L'appareillage electronique est classe en neuf rubriques et une description sommaire des principaux appareils est donnee dans chacune des rubriques. La tenue en service du materiel est satisfaisante, ainsi que le montre la frequence moyenne des pannes observees par 1000 heures de fonctionnement. (auteur)

  1. Attempt of absolute analysis with spark source mass spectrometry; Essai d'analyse absolue par spectrometrie de masse a etincelles

    Energy Technology Data Exchange (ETDEWEB)

    Desjardins, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-10-01

    By means of a graphical method developed in our laboratory, we have studied the linearity of the response of the MS-7 mass spectrometer for impurity determinations over a concentration range of 1 to 1000 ppm (parts per million of atoms). This method consist in transforming optical density measurements into 'true intensities', which are plotted on a logarithm-scale paper against the exposures. A moving transparent ruler graduated at the inverse scale of the exposures allows us to determine directly on the graph, the concentration of impurities in ppm. We have used this method for the determination of sensitivity coefficients in standard samples such as Al, Fe, Cu, Ni, Zr, and non conducting powders like SiO{sub 2} and Al{sub 2}O{sub 3}. This study shows that, for the samples studied, the sensitivity coefficients are practically independent of the matrix and the concentration. Moreover the results show the possibility of obtaining an absolute analysis by spark source mass spectrometry. (author) [French] Au moyen d'une methode graphique developpee ou laboratoire, nous avons etudie la linearite des determinations d'impuretes au spectrometre de masse, type MS-7, dans un domaine de concentration allont de 1 a 1000 ppm. Cette methode consiste en la transformation des mesures de densite optique en 'intensite vraie'. Ces dernieres mesures sont portees sur un graphique logarithmique et une reglette transparente graduee a l'inverse de l'echelle des expositions nous permet de determiner directement la teneur des impuretes en ppm (partie par million d'atomes). Nous avons utilise cette methode pour la determination des coefficients de sensibilite dans des echantillons etalons tels que Al, Fe, Cu, Ni, Zr, et des poudres non conductrices genre SiO{sub 2}, Al{sub 2}O{sub 3}. Cette etude a montre que, pour les echantillons etudies, les coefficients de sensibilite sont pratiquement independants de la matrice et de la concentration. De plus, les resultats obtenus montrent la

  2. Conception et calibration d'un sonoreacteur pour l'oxydation de la cellulose par le systeme TEMPO/NaOCl/NaBr

    Science.gov (United States)

    Paquin, Michel

    grande consommation d'energie et de reactif qui rend le procede difficilement accessible au milieu industriel. L'utilisation des ultrasons lors de la reaction d'oxydation permet de reduire de 50% le temps de reaction et d'autant la consommation de produits chimiques. Actuellement le processus d'oxydation s'effectue en mode discontinu pour une quantite de 20 grammes de pate dans un reacteur en verre dans un bain a ultrason. L'objectif principal de ce travail est d'elaborer un sonoreacteur en mode semi-continu afin d'etre en mesure de transferer une reaction d'oxydation du mode discontinu en mode semi-continu. Le transfert de reaction sera effectue en realisant la calibration de l'activite acoustique des deux differents reacteurs, discontinu et semi-continu, par la methode de Weissler. La methode de Weissler quantifie le taux de production radicalaire en mesurant la formation d'iode moleculaire d'une solution aqueuse d'iodure de potassium sous ultrason. Suite a sa calibration, le sonoreacteur pilote (mode semi-continu) a demontre une augmentation de la production radicalaire de 683 % a 170 kHz en comparaison avec l'utilisation d'un bain a ultrason a la meme frequence. Lors de la reaction d'oxydation, la puissance optimale utilisee dans le bain a ultrason a 170 kHz est de 1000 W. La puissance utilisee selon les resultats de calibration obtenue dans le sonoreacteur pilote est de 125 W soit une diminution de l'energie appliquee de 87,5 %. Lors de la reaction d'oxydation, le taux de production des groupements carboxylates est de 2,6 mmol COOH kg/min dans le bain a ultrason et de 6,87 mmol COOH kg/min dans le sonoreacteur pilote soit une augmentation de 164% du taux de formation. Selon les resultats obtenus, l'utilisation d'un sonoreacteur en mode continu peut etre envisageable pour la reaction d'oxydation de la cellulose par le systeme TEMPO-NaOCl-NaBr en industrie au niveau industriel.

  3. Etude par resistivite electrique du comportement d'un alliage amorphe Fe 40Ni 38Mo 4B 18 deforme par traction

    Science.gov (United States)

    Hoang, Long Phan; Sacovy, Paulette; Delaplace, Jean

    1983-02-01

    Des rubans d'alliages amorphes Metglas du type Fe 40Ni 38Mo 4B 18 à l'état brut de trempe ont été déformés par traction à la température ambiante et l'on a suivi les variations de la résistance électrique des échantillons au cours de la déformation. Il ressort de ces essais que la déformation plastique qui est de l'ordre de 0.5% avant rupture ne se produit pas de faĉon homogène dans l'échantillon. Les mesures électriques effectuées au cours de la déformation mettent en évidence dans le domaine élastique un effet d'élastorésistance, relativement important ( K ≠ 1); elles montrent que dans le domaine plastique la déformation permanente des échantillons s'accompagne d'une diminution de la résistivité électrique du matériau. Deux hypothèses sont discutées pour expliquer cet effet inattendu, l'un qui fait appel à l'existence de volumes libres, l'autre qui suppose une cristallisation localisée du matériau sous l'effet de la contrainte.

  4. The reactor Melusine - radiation measurements carried out at the start of operation and during the first ascents to power; Pile Melusine - mesures de rayonnement effectuees au demarrage et pendant les premieres montees en puissance

    Energy Technology Data Exchange (ETDEWEB)

    Coutrot, V; Delpuech, J; Fitoussi, L [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This report gives the results of radiation measurements carried out on the first C.E.A. swimming-pool pile, Melusine. The purpose of these measurements, which were carried out during the starting-up period and the first ascents to 1 MW power, is to check the radiation intensity levels near the pile and from this to verify the safety calculation methods used. In addition certain special measurements, such as those performed in and above the water of the swimming-pool, in the channels and outside them etc..., should make it possible eventually to define the conditions under which the pile may be used for special jobs with less protection. In the first part of the report are given the results of radiation measurements carried out during runs at low power plateaux not exceeding 500 W: in particular measurements at variable water levels in the water of the swimming-pool and on the axis of the open channels. The results given in the second part deal with radiation measurements performed in various parts of the premises, studies on the activation of the plugs in the experimental channels and of the materials in the forward compartment, and also of the radioactivity of the swimming-pool water and the air used to cool the channels. (author) [French] Le present rapport a pour but de donner les resultats des mesures de rayonnement effectuees aupres de la premiere pile piscine du C.E.A.: la pile Melusine. Le but de ces mesures, effectuees pendant la periode de demarrage et les premieres montees a la puissance de 1 MW, est de controler les niveaux d'intensite de rayonnement aupres de la pile et par la de juger des methodes de calculs de protection utilisees. D'autre part, certaines mesures plus particulieres, telles que celles effectuees dans l'eau et au-dessus de l'eau de la piscine, dans les canaux et a l'exterieur de ceux-ci, etc..., doivent permettre de definir ulterieurement les conditions d'utilisation de la pile pour des fonctionnements particuliers avec des protections

  5. Non-Destructive Testing of Plutonium-Enriched Fuel Rods; Controles non Destructifs de Barreaux Combustibles Enrichis au Plutonium; Nedestruktivnyj-kontrol' toplivnykh sterzhnej''obogashchennykh plutoniem; Ensayo no Destructivo de Elementos Combustibles Enriquecidos en Plutonio

    Energy Technology Data Exchange (ETDEWEB)

    Libotte, P.; Inniger, H.; Leblanc, J. M. [Centre D' Etude de l' Energie Nucleaire, Societe Belge pour l' Industrie Nucleaire, S.A. (Belgonucleaire), Mol (Belgium)

    1965-09-15

    ultrasonically by the pulse-echo technique. The respective advantages of the various non-destructive techniques are studied in relation to the required accuracy and to their possible application to the automated inspection of plutonium fuel rods fabricated on an industrial scale. (author) [French] La Societe belge pour l'industrie nucleaire (BelgoNucleaire) et le Centre d'etude de l'energie nucleaire (CEN) etudient sous contrat, en cooperation avec la Commission de l'EURATOM, l'utilisation du plutonium dans les reacteurs de puissance a eau pressurisee. Dans le cadre des recherches entreprises, differentes techniques de controle non destructif ont ete mises au point en vue d'evaluer la qualite des barreaux combustibles fabriques. Les essais non destructifs mis au point et decrits dans le memoire sont utilises essentiellement pour le controle des dimensions et de la qualite des tubes de gainage, de l'integrite des soudures, de l'etancheite des barreaux, de la densite du materiau combustible et de sa repartition, de l'enrichissement en plutonium et de sa distribution radiale et axiale dans le barreau combustible. Les methodes utilisees pour ces essais non destructifs comportent principalement les examens par radiographie, par autoradiographie, par gammagraphie et par les ultrasons. Le document reprend le principe de chacune des mesures realisees, et decrit dans chaque cas l'appareillage utilise et les techniques operatoires appliquees en vue d'obtenir les sensibilites et precisions desirees. La technique utilisee pour la radiographie permet de deceler des defauts de l'ordre de 50 a 60 {mu}m dans les soudures d'extremite des barreaux combustibles. Les combustibles etant densifies par vibration de trois fractions de poudre dense, dont la fraction fine seule comporte l'enrichissement en plutonium, il est essentiel que la repartition de ce dernier, de meme que la distribution de la densite, soient relevees avec precision. Le comptage du rayonnement gamma emergent emis par le plutonium

  6. A critical summary of microscopic fast-neutron interactions with reactor structural, fissile and fertile materials; Apercu critique des interactions microscopiques des neutrons rapides avec les materiaux de construction et les matieres fissiles et fertiles utilisees dans les reacteurs; Kriticheskij obzor mikroskopicheskog o vzaimodejstviya bystrykh nejtronov s konstruktsionnymi, rasshcheplyayushchimis ya i vosproizvodyashchim i reaktornymi materialami; Resumen critico de las interacciones microscopicas de los neutrones rapidos con los materiales estructurales fisionables y fertiles utilizados en los reactores

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A B [Argonne National Laboratory, Argonne, IL (United States)

    1962-03-15

    Prevailing knowledge of fast-neutron-induced reactions utilized in the nuclear design of reactor systems is reviewed. Principal emphasis is placed upon microscopic experimental methods, results and precisions. Fast-neutron scattering is considered in detail, including the results of experimental determinations of scattering from oxygen, iron, zirconium, niobium, tungsten, thorium and uranium. Representative results of experimental studies of fast-neutron capture and fast-neutron-induced fission are given. The measurements discussed not only provide results of considerable applied usefulness but axe also examples of the application of advanced experimental nuclear techniques. Areas of limited, conflicting or non-existent experimental information are outlined. A prognosis of future knowledge of fast-neutron reactions is made, with emphasis on the fulfillment of reactor requirements for basic nuclear data. (author) [French] L'auteur fait le point des connaissances sur les reactions provoquees par les neutrons rapides sur lesquelles on tend a fonder les projets de reacteurs. Il met en relief les methodes, les resultats et la precision de mesures experimentales a l'echelle microscopique. Il etudie en detail la diffusion des neutrons rapides, et donne les resultats de mesures experimentales de diffusion dans l'oxygene, le fer, le zirconium, le niobium, le tungstene, le thorium et l'uranium. Il donne les resultats les plus significatifs d'etudes experimentales sur la capture des neutrons rapides et sur la fission provoquee par des neutrons rapides. Les mesures etudiees, non seulement fournissent des renseignements d'une utilite pratique considerable, mais aussi constituent des exemples de l'application de techniques experimentales nucleaires a la pointe du progres. L'auteur indique les domaines ou les donnees experimentales sont limitees, contradictoires ou inexistantes. Il se livre a des pronostics sur le developpement des connaissances experimentales en matiere de

  7. The neutronic method for measuring soil moisture; La methode neutronique de mesure de l'humidite des sols

    Energy Technology Data Exchange (ETDEWEB)

    Couchat, Ph [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1967-07-01

    The three group diffusion theory being chosen as the most adequate method for determining the response of the neutron soil moisture probe, a mathematical model is worked out using a numerical calculation programme with Fortran IV coding. This model is fitted to the experimental conditions by determining the effect of different parameters of measuring device: channel, fast neutron source, detector, as also the soil behaviour under neutron irradiation: absorbers, chemical binding of elements. The adequacy of the model is tested by fitting a line through the image points corresponding to the couples of experimental and theoretical values, for seven media having different chemical composition: sand, alumina, line stone, dolomite, kaolin, sandy loam, calcareous clay. The model chosen gives a good expression of the dry density influence and allows {alpha}, {beta}, {gamma} and {delta} constants to be calculated for a definite soil according to the following relation which gives the count rate of the soil moisture probe: N = ({alpha} {rho}{sub s} +{beta}) H{sub v} +{gamma} {rho}{sub s} + {delta}. (author) [French] La theorie a trois groupes etant choisie comme le moyen le plus adequat pour determiner la reponse de l'humidimetre, une mise en forme d'un modele mathematique est effectuee grace a un programme de calcul numerique ecrit en code Fortran IV. Cette representation est adaptee a l'experience par l'etude de l'influence de parametres du systeme de mesure: tubage, source, detecteur, et du comportement du sol vis-a-vis des neutrons: presence d'absorbeurs, liaison chimique des elements. La validite du modele est testee par ajustement d'une droite aux points images des couples de valeurs experimentales et theoriques, ceci pour sept milieux distincts definis par leur composition chimique: sable, alumine, calcaire, dolomie, kaolin, limon sableux, argile calcaire. Le modele prevoit, bien l'influence de la densite seche et permet de calculer pour un sol donne les constantes

  8. Contribution to the study of thermal mixing between nuclear spin systems; Contribution a l'etude du melange thermique entre systemes de spins nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Goldmann, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-02-15

    This work describes methods of dynamic nuclear polarization in solids based on the thermal mixing between nuclear spin systems. The description of the thermal mixing processes involves most of the fundamental aspects of the spin temperature theory. The experiments, conducted with paradichlorobenzene and para-dibromobenzene, yield a detailed confirmation of the theoretical predictions. (author) [French] Ce travail decrit des methodes de polarisation dynamique nucleaire dans les solides basees sur le melange thermique entre systemes de spins nucleaires. La description des processus de melange thermique met en jeu la plupart des aspects fondamentaux de la theorie de la temperature de spin. Les experiences, realisees avec du paradichlorobenzene et du paradibromobenzene, apportent une confirmation detaillee des previsions theoriques. (auteur)

  9. Experimental methods of reactor physics; Methodes experimentales de physique des reacteurs a neutrons thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D; Lafore, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    ) Mesures par neutrons pulses: dispositif utilise et precision, application aux mesures de {lambda}t et aux mesures d'antireactivite, application au graphite, a l'eau ordinaire et au Be0. b) Mesures par oscillation (M. VIDAL): appareillage utilise et precision obtenue, application aux mesures de sections efficaces effectives et aux integrales de resonnance. c) Fluctuation: appareils utilises et techniques de mesures. III - MESURES PAR EMPOISONNEMENT. Description des methodes d'introduction et d'extraction du poison, difficultes rencontrees sur l'eau legere et sur l'eau lourde mesures des coefficients de temperature et antireactivite. IV - MESURES SPECTRALES: Choix et mise au point des detecteurs, difficultes de mesures, application aux mesures spectrales en vue d'etude de thermalisation, application a la dosimetrie. V - MESURES EXPERIMENTALES DE PROTECTION: On presente les techniques et les appareillages recemment mis au point dans ce domaine. (auteurs)

  10. Review of Development Status of Nuclear Superheat; Expose sur l'etat actuel des travaux concernant la surchauffe nucleaire; Obzor razrabotki voprosa o yadernykh peregrevatelyakh; Estudio de los progresos realizados en niateria de sobrecalentamiento nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Imhoff, D. H.; Pennington, R. T. [General Electric Company, San Jose, CA (United States)

    1963-10-15

    fuel irradiation performance, in-pile and out-of-pile uniform and localized corrosion evaluations, results from thermal superheat critical experiments, results from experimental heat-transfer testing and a brief appraisal of the economic incentives of the separate superheat reactor, integral superheat reactor, and mixed-spectrum superheat reactor design studies. (b) A brief description is given of the USAEC-Sponsored ESADA-VESR nuclear superheat fuel development programme. The development tasks, the initial core superheat fuel-element design, the range of experimental variables, and the expected results for the three-year fuel development programme are discussed. (author [French] Depuis 1959, la Societe General Electric s'occupe activement de mettre au point la surchauffe nucleaire dans les reacteurs ralentis a l'eau ordinaire. A cette epoque, le ''Superheat Advance Demonstration Experiment'' (SADE), finance par la societe, a permis d'obtenir, pour la premiere fois aux Etats-Unis, de la vapeur surchauffee par un dispositif nucleaire. Les auteurs du memoire font le point de la situation actuelle concernant la surchauffe nucleaire. Ils decrivent, dans une premiere partie, les trois principales installations de surchauffe nucleaire utilisees par la General Electric et, dans la seconde, les deux principaux programmes de recherches sur la surchauffe ainsi que les resultats les plus importants obtenus jusqu'ici dans ce domaine. 1. Principales installations pour les experiences de surchauffe: a) Breve description du SADE utilise dans le reacteur a eau bouillante de Vallecitos (VBWR), avec tableaux des conditions dans lesquelles se deroulent les experiences, et des elements combustibles irradies pendant la periode comprise entre mai 1959 et juin 1962; puis examen critique des resultats les plus importants ainsi obtenus. b) Breve description de l' ''Expanded Superheat Advance Demonstration Experiment'' (E-SADE) installe dans le reacteur de Vallecitos, avec tableaux des

  11. Mesures experimentales de l'impact des revetements hydrophobeset superhydrophobes sur la trainee et la portance d'un profil aerodynamique propre et glace

    Science.gov (United States)

    Villeneuve, Eric

    Ce projet, realise a la demande du Laboratoire International des Materiaux Antigivre, a pour but de mesurer et definir experimentalement l'impact de revetements hydrophobes sur les coefficients de trainee et de portance d'un profil NACA 0012. Pour ce faire, la balance aerodynamique du LIMA devait tout d'abord etre amelioree afin d'offrir une sensibilite suffisante pour realiser le projet. Plusieurs ameliorations ont ete faites, comme le changement des cellules de charge, la diminution du nombre de cellules de charge, le changement du cadre de la balance, etc. Une fois ces ameliorations terminees, la reproductibilite, l'exactitude et la sensibilite ont ete valides afin de s'assurer de la fiabilite des resultats offerts par la balance. Pour les angles d'attaque etudies avec les revetements, soient -6° et 0°, la balance a une reproductibilite de +/-2,06% a 360 000 de nombre de Reynolds. Pour valider la sensibilite, des essais a -6° et 0° d'angle d'attaque et des nombres de Reynolds de 360 000 et 500 000 ont ete faits avec des papiers sables. Les resultats de ces essais ont permis de, tracer des courbes de tendances du coefficient de trainee du NACA 0012 en fonction de la rugosite de surface et d'etablir la valeur de la sensibilite de la balance a +/-8 mu m. Cinq revetements populaires ont ete choisis pour l'experimentation, soient le Wearlon, le Staclean, le Hirec, le Phasebreak ainsi que le Nusil. Les revetements sont soumis aux memes conditions experimentales que les papiers sables, et une rugosite equivalente est trouvee par extrapolation des resultats. Cependant, les rugosites equivalentes de surfaces different entre -6° et 0°. Les essais avec le Staclean et le Hirec donnent des coefficients de trainee equivalent a ceux avec l'aluminium, alors que le Wearlon, le Nusil et le Phasebreak donnent une augmentation du coefficient de trainee de 13%, 17% et 25% respectivement par rapport a l'aluminium. Pour les coefficients de portance, la balance ne detecte pas l

  12. The determination of iodine in biological media using radioactivation analysis (1962); Dosage de l'iode dans les milieux biologiques au moyen de l'analyse par radioactivation (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Comar, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The object of this study is to show that the application of radioactivation analysis to the determination of iodine in biological media makes it possible to measure iodine concentrations of the order of 0.0001 {mu}g. After a review of the chemical methods with a mention of the difficulties they present, the optimum conditions for the determination of iodine in biological liquids are given. Three methods are described: - the first consists of a chemical treatment which liberates the protein bound iodine in an inorganic form. After distillation this iodine is irradiated in a flux of thermal neutrons. The induced radioactivity is compared to that of a standard sample irradiated in the same conditions by {gamma} spectrometry. - the second method which is of more general application consists in irradiating the sample and then extracting the iodine; its induced radio-activity is then measured by {beta}-counting. - the third method measures the iodine directly in the thyroid tissue by anti-compton spectrometry. The sensitivity, the reproducibility and the accuracy are discussed. Some applications are described: determination of iodine in its various organic forms in serum, determination of iodine in urines, in food-stuffs, etc., in the thyroid tissue, etc. (author) [French] Le but de cette etude est de montrer que l'analyse par radioactivation appliquee au dosage de l'iode dans les milieux biologiques permet de mesurer des taux d'iode de l'ordie de 0,0001 {mu}g. Apres avoir rappele le principe des methodes chimiques et montre les difficultes de leur mise en oeuvre, il est etabli les conditions optima pour realiser le dosage de l'iode dans les liquides biologiques. Trois methodes sont decrites; - la premiere consiste a pratiquer un traitement chimique liberant l'iode proteique sous forme minerale. Apres distillation cet iode est irradie dans un flux de neutrons thermiques. La radioactivite induite est mesuree comparativement a celle d'un etalon traite dans les memes

  13. Analytic catalog for the use of the nuclear physicists; Repertoire analytique a l'usage des physiciens nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R; Barloutaud, R; Bernas, R; Chaminade, R; Cohen, R; Conjeaud, M; Cotton, E; Faraggi, H; Grjebine, T; Laboulaye, H de; Lehmann, P; Leveque, A; Levi, C; Moreau, J; Naggiar, V; Olkowsky, J; Papineau, L; Papineau, L; Prugne, P; Schuhl, C; Szteinsznaider, D; Tzara, C; Valladas, G [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires; Marty, N; Renard, G [College de France, Lab. de Chimie Nucleaire (France)

    1952-07-01

    The problem of the documentation in nuclear physics becomes constantly more complex. Every week brings its share of publications, always more numerous and more varied. To remedy to this problem, we tried, at the Nuclear Physics Services of the CEA, to give to the documentation the character of a collective and systematized work. The present report covers the literature appeared between January 1, 1950 and July 1, 1951. (Volume 1: CEA report number 120; Volume 2: CEA report number 184). (M.B.) [French] Le probleme de la documentation en physique nucleaire devient sans cesse plus complexe. Chaque semaine apporte son lot de publications, toujours plus nombreuses et plus diversifiees. C'est pour essayer de porter remede a cet etat de choses que nous avons essaye, au service de Physique Nucleaire du C.E.A., de donner a la documentation le caractere d'un travail collectif systematise. Le present rapport couvre la litterature parue entre le 1 Janvier 1950 et le 1 Juillet 1951. (Tome 1: Rapport CEA numero 120; Tome 2: Rapport CEA numero 184). (M.B.)

  14. Isotopic analysis of plutonium by optical spectroscopy; Analyse isotopique du plutonium par spectroscopie optique

    Energy Technology Data Exchange (ETDEWEB)

    Artaud, J; Chaput, M; Gerstenkorn, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Isotopic analysis of mixtures of plutonium 239 and 240 has been carried out by means of the photo-electric spectrometer Fabry-Perot, the source being a hollow cathode cooled by liquid nitrogen. This first research has been concerned with finding among the spectral lines given by the hollow cathode, those suitable for use in analysis. Actually, the relative precision is of the order of 2 per cent (for samples containing 3 per cent of {sup 240}Pu). The study of the reproducibility of the measurements should make it possible to increase the precision; the relative precision which can be expected from this method should be 1 per cent for mixtures containing 1 per cent of {sup 240}Pu. (author) [French] L'analyse isotopique des melanges de plutonium 239 et 240 a ete effectuee a l'aide du spectrometre photoelectrique Fabry-Perot, la source etant une cathode creuse refroidie a l'azote liquide. Ce premier travail a eu pour but de discerner parmi les raies spectrales emises par la cathode creuse, celles susceptibles de servir de raies d'analyse. Actuellement, la precision relative est de l'ordre de 2 pour cent (pour des echantillons contenant 3 pour cent de {sup 240}Pu). L'etude de la reproductibilite des mesures devrait permettre d'ameliorer la precision; la precision relative que l'on pourrait atteindre par cette methode serait de 1 pour cent pour des melanges contenant 1 pour cent de {sup 240}Pu. (auteur)

  15. Magnetic resonance studies of solid polymers; Etude des polymeres solides par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Lenk, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    This paper is a review of the application of nuclear magnetic resonance (NMR) to solid polymers. In the first, theoretical part, the elements of the theory of NMR, which are necessary for the study of the properties of solid polymers are discussed: the moments method, nuclear relaxation and the distribution of correlation times. In the second part the experimental results are presented. (author) [French] Cette etude est une recherche bibliographique sur l'application de la resonance magnetique nucleaire (RMN) aux polymeres solides. Dans la premiere partie theorique on discute les elements de la theorie de RMN, necessaires pour l'etude des proprietes des polymeres solides: la methode des moments, la relaxation nucleaire et la distribution des temps de correlation. La deuxieme partie presente les resultats des experiences. (auteur)

  16. Separation of Graphitic Line in Debyegram of the Reactor Graphite; Separation de la raie graphitique dans le debyegramme du graphite nucleaire; Otdelenie linii grafita v debaiegramme reaktornogo grafita; Separacion de la linea grafitica en el diagrama de debye del grafito nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Pandic, B. [Institut Rudjer Boskovio, Zagreb, Yugoslavia (Croatia)

    1963-11-15

    The author sets forth a method for the determination of crystallite dimensions L{sub c} in reactor graphite. The method consists of the mathematical correction of the diffraction profile (002) obtained by means of a Philips diffractometer with scintillation counter. During the work CuK{sub {beta}} radiation is used. The convenience of using CuK{sub {beta}} radiation rather than that of a CuK{sub {alpha}} doublet is discussed. All instrumental errors except that of the sample adsorption are eliminated using corresponding slits. Sample adsorption is corrected mathematically. Highly symmetrical lines of graphitic and non-graphitic phase could be analytically separated from such corrected line profiles. Experimental error in the determination of the half-height and half-width of these lines does not exceed 5%. (author) [French] On a elabore une methode pour determiner la hauteur moyenne L{sub c} des cristallites du graphite nucleaire. Il s'agit d'une methode mathematique de correction du profil de la raie de diffraction (002), obtenu par le diffractometre Philips avec un compteur a scintillation. On a discute les avantages des rayons CuK{sub {beta}} par rapport au doublet CuK{sub {alpha}}. Le choix des ouvertures elimine toutes les erreurs, sauf l'erreur d'absorption dans les echantillons, que l 'on ecarte mathematiquement. Les raies de diffraction pures et tres symetriques des phases graphitique et non graphitique peuvent etre separees du profil corrige de cette facon. L'incertitude dans la mesure de la demi-largeur de ces raies n'est pas superieure a 5%. (author) [Spanish] El autor de la memoria expone un metodo para determinar la altura media Lc de las cristalitas del grafito nuclear. Consiste en corregir matematicamente el perfil de la linea de difraccion (002) obtenido con un difractometro Philips y un contador de centelleo. En la memoria se explican las ventajas que la radiacion CuK{sub {beta}} ofrece sobre el doblete CuK{sub {alpha}} Si se elige correctamente la

  17. The Management of Nuclear Materials in a Research Establishment; Gestion des Matieres Nucleaires dans un Centre de Recherche; Uchet yadernykh materialov v nauchno-issledovatel'skom uchrezhdenii; Administracion de Sustancias Nucleares en un Centro de Investigaciones

    Energy Technology Data Exchange (ETDEWEB)

    Wright, W. J.; Hocking, D. R. [Australian Atomic Energy Commission Research Establishment, Lucas Heights, NSW (Australia)

    1966-02-15

    The functions of a nuclear materials management scheme are reviewed in relation to the activities of research establishments. Since these activities are normally non-repetitive, there is little opportunity to establish statistical quality and quantity control. The risks of an error in the material accounts must therefore be established from relatively few analytical measurements and the implications of this are discussed. Similar arguments are applied to illustrate the difficulties of quality control on suppliers when a large variety of materials are being purchased in small quantities. (author) [French] Les auteurs examinent le role d'un systeme de gestion des matieres nucleaires applique aux activites des centres de recherche. Comme ces activites ne sont normalement pas appelees a se repeter, il n'est guere possible d'organiser un controle statistique quantitatif et qualitatif. Il faut donc determiner les possibilites d'erreurs dans la comptabilite matieres en s'appuyant sur un nombre relativement restreint de mesures analytiques et les auteurs examinent les conclusions a tirer de cette situation. Ils recourent a une argumentation analogue pour illustrer les difficultes inherentes au controle de la qualite des matieres livrees par les fournisseurs lorsqu'il doit porter sur une grande diversite de matieres en petites quantites. (author) [Spanish] Los autores examinan el funcionamiento de un sistema de administracion de materiales nucleares en relacion con las actividades de los centros de investigaciones. Como estas actividades son por lo comun muy diversas, hay pocas oportunidades de establecer un control estadistico de la calidad y la cantidad. Por ello es necesario determinar los riesgos de error en la contabilidad de los materiales partiendo de un numero relativamente reducido de mediciones analiticas; en la memoria se examinan las consecuencias de este hecho. Los autores aplican razonamientos analogos para poner de manifiesto las dificultades con que, en el

  18. Directed and persistent movement arises from mechanochemistry of the ParA/ParB system.

    Science.gov (United States)

    Hu, Longhua; Vecchiarelli, Anthony G; Mizuuchi, Kiyoshi; Neuman, Keir C; Liu, Jian

    2015-12-22

    The segregation of DNA before cell division is essential for faithful genetic inheritance. In many bacteria, segregation of low-copy number plasmids involves an active partition system composed of a nonspecific DNA-binding ATPase, ParA, and its stimulator protein ParB. The ParA/ParB system drives directed and persistent movement of DNA cargo both in vivo and in vitro. Filament-based models akin to actin/microtubule-driven motility were proposed for plasmid segregation mediated by ParA. Recent experiments challenge this view and suggest that ParA/ParB system motility is driven by a diffusion ratchet mechanism in which ParB-coated plasmid both creates and follows a ParA gradient on the nucleoid surface. However, the detailed mechanism of ParA/ParB-mediated directed and persistent movement remains unknown. Here, we develop a theoretical model describing ParA/ParB-mediated motility. We show that the ParA/ParB system can work as a Brownian ratchet, which effectively couples the ATPase-dependent cycling of ParA-nucleoid affinity to the motion of the ParB-bound cargo. Paradoxically, this resulting processive motion relies on quenching diffusive plasmid motion through a large number of transient ParA/ParB-mediated tethers to the nucleoid surface. Our work thus sheds light on an emergent phenomenon in which nonmotor proteins work collectively via mechanochemical coupling to propel cargos-an ingenious solution shaped by evolution to cope with the lack of processive motor proteins in bacteria.

  19. Absolute analysis of uranium isotopic concentrations with a gas ion source mass spectrometer; Analyses absolues des concentrations isotopiques de l'uranium par spectrometre de masse equipe d'une source a gaz

    Energy Technology Data Exchange (ETDEWEB)

    Chaussy, L.; Boyer, R. [Commissariat a l' Energie Atomique, Pierrelatte (France)

    1969-07-01

    Mass spectrometer with electronic bombardment ions source for routine uranium isotopic analysis are used like relative measurements apparatus. We show that such mass spectrometers can be used for absolute measurements with a very high sensitivity and precision which are ten times better than theses of thermo-ionic ions source mass spectrometer. We examine the causes of systematic errors and we give experimental data. In particular natural uranium sample used as reference give: U{sub 5} = 0.7202 {+-} 0.0005 atoms per cent; U{sub 4} = 0.00552 {+-} 0.0003 atoms per cent. The use of this method is justified for standards control. (authors) [French] Les spectrometres de masse a source par bombardement electronique pour l'analyse de l'uranium sous forme d'hexafluorure, sont utilises en routine comme des appareils de mesure relative. On montre que l'on peut utiliser de tels appareils pour effectuer des mesures absolues avec une excellente sensibilite et reproductibilite, dix fois superieure a celle des spectrometres a source thermoionique. On examine en detail les causes d'erreurs systematiques et on donne des resultats experimentaux. En particulier, l'analyse d'un echantillon d'uranium naturel donne: U{sub 5} = 0.7202 {+-} 0.0005 atomes pour cent; U{sub 4} = 0.00552 {+-} 0.0003 atomes pour cent. La technique de mesure est utile pour le controle d'etalons isotopiques. (auteurs)

  20. Study of FeC1{sub 2} by neutron diffraction; Etude de Fe C1{sub 2} par diffraction de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Herpin, A; Meriel, P [Commissariat a l' Energie Atomique, Saclay (France)

    1959-07-01

    Magnetic measurements have shown that anhydrous ferrous chloride behaves as a metamagnetic at temperatures below 24 deg. K, in other words as an antiferromagnetic sensitive to the action of an external field of moderate strength. The aim of the neutron diffraction study is to determine precisely the arrangement of the magnetic moments, and to follow its evolution as a function of the applied field. (author) [French] Des mesures magnetiques ont montre que le chlorure ferreux anhydre se comporte comme un metamagnetique a une temperature inferieure a 24 deg. K, c'est a dire comme un antiferromagnetique sensible a l'action d'un champ exterieur modere. L'etude par diffraction de neutrons a pour buts de preciser la disposition des moments magnetiques et de suivre son evolution en fonction du champ applique. (auteur)

  1. Measurement of the production of K{sup +} mesons by protons in nuclei (1960); Mesure de la production des mesons K{sup +} par des protons dans les noyaux (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Teiger, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-07-01

    K{sup +} mesons produced by the internal proton beam of Saturne have been identified by means of scintillation and Cerenkov counters. The production cross sections are given per target nucleus measured at a laboratory angle of 35 deg. as well as the cross section relative to {pi}{sup +} mesons of the same momentum for: - incident protons of kinetic energy between 1.3 and 2.8 GeV, - targets of C, Cu and Pb, - K{sup +} produced with kinetic energies between 0.45 and 0.65 GeV. From these results we have tried to deduce the importance of indirect production by intermediate {pi} mesons with respect to direct production by proton-nucleon collisions. (author) [French] Au moyen de detecteurs a scintillations et a rayonnement Cerenkov, on a identifie les mesons lourds K{sup +} produits par les protons du faisceau interne de 'Saturne'. On donne les sections efficaces de production, par noyau cible, mesurees a 35 deg. dans le laboratoire, ainsi que les sections efficaces relatives par rapport aux mesons {pi}{sup +} de meme impulsion pour: - des protons incidents d'energie cinetique entre 1,3 GeV et 2,8 GeV, - des cibles de C, de Cu et de Pb, - des K{sup +} produits avec des energies cinetiques entre 0,45 et 0,65 GeV. De ces resultats, on a essaye de deduire l'importance de la production indirecte, par mesons {pi} intermediaires, par rapport a la production directe dans un choc proton-nucleon. (auteur)

  2. Élaboration, fiabilité et utilisation d’un outil de mesure de l’environnement alimentaire dans les supermarchés de quatre quartiers de Montréal (Canada

    Directory of Open Access Journals (Sweden)

    Élise Jalbert-Arsenault

    2017-01-01

    égiques par supermarché. Le prix des PAUT était inversement associé à leur proéminence (p < 0,005 et à leur promotion (p < 0,003. La taille du magasin était associée au nombre de présentoirs et au positionnement stratégique des PAUT (p < 0,001 mais pas à celui des FL, et elle était inversement associée au prix des boissons gazeuses (p < 0,003. Conclusion : Cette étude illustre la variabilité de l’environnement alimentaire entre les supermarchés et souligne l’importance de mesurer les caractéristiques en magasin pour brosser un tableau juste de l’environnement alimentaire du consommateur.

  3. Measurement of {beta} Emitters by the Radiated Charge; Mesure des Emetteurs {beta} par la Charge Rayonnee. Mesure de l'activite des emetteurs {beta} a partir de la charge rayonnee; Izmerenie aktivnosti izluchatelya {beta}-chaetits na osnove izluchaemogo zaryada; Medicion de la actividad de los emisores {beta} a partir de la carga irradiada

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, J J [Centre d' Etudes Nucleaires de Saclay (France)

    1960-06-15

    The method is based on the principle recently described by Failla and his associates: Two plane electrodes of the same material are mounted parallel to, and close beside, each other in a vacuum container and the source which is to be measured is laid on one of them. The back-scattering on this electrode is offset by the reflections on the other electrode. A magnetic or electrical field makes it possible to eliminate the effect of low-energy secondary electrons. In the case of magnetic deflection, the apparatus includes an extrapolation chamber and, in the case of electrical deflection, a chamber with a very fine grille. In the case of Sr{sup 90}-Y{sup 90} and P{sup 32} the results obtained tally very well with the measurements made with the 4 {pi} counter (better than {+-} 2%) In the case of S{sup 35} the results are seen to be affected by the atomic number of the substance of which the electrode whereon the source is placed consists; this must therefore be chosen with care. The theories on back-scattering provide an explanation of these results. (author) [French] Le principe de la methode est celui decrit recemment par Failla et ses collaborateurs: Deux electrodes planes paralleles, de meme substance et tres voisines, sont disposees dans une enceinte videe. Sur une des electrodes est deposee la source a mesurer. La retrodiffusion sur l'electrode porte-source est compensee par les reflexions sur l'autre electrode. Un champ magnetique ou electrique permet d'eliminer l'effet des electrons secondaires de faible energie. Le dispositif experimental comporte, dans le cas de la deflexion magnetique, une chambre a extrapolation et dans le cas de la deflexion electrique, une chambre a grille tres fine. L'accord avec des mesures effectuees au compteur 4 {pi} est excellent dans le cas du Sr{sup 90}-Y{sup 90} et du P{sup 32} (mieux que {+-}2%). Dans le cas du S{sup 35}, les experiences mettent en evidence l'influence du nombre atomique du support de source et en imposent le

  4. Determination of tritium by counting; Dosage du tritium par comptage

    Energy Technology Data Exchange (ETDEWEB)

    Schott, R; Froment, G; Pinson, J; Genty, C [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1968-07-01

    Ionisation chamber assay of tritium in any gaseous mixture is a simple, fast and accurate method. We used the method of relative determination by comparison to a standard rather than the method of absolute assay in which case the constants are known with too little accuracy. The efficiency of the chamber was studied in connection to the pressure inside the chamber and its total volume. The calibration is linear in the range we are taking into account (1 to 80 millicuries). The reproducibility of the method is good: 13 runs gave a coefficient of variation of 1.6 per cent. The relative accuracy was found equal to {+-} 1.3 per cent. To end the paper, we describe in detail the apparatus and the ways of proceedings. (authors) [French] Le comptage du tritium par chambre d'ionisation est une methode simple, rapide et precise pour determiner la teneur en tritium d'un melange gazeux quelconque. Nous avons prefere utiliser la methode de determination relative par rapport a un etalon car, dans le cas d'une determination absolue, les constantes sont connues avec une trop grande incertitude. L'efficacite de la chambre a ete etudiee en fonction de la variation de la pression d'argon a l'interieur de la chambre et du volume total, de cette derniere. L'etalonnage s'est revele lineaire dans le domaine de mesures qui nous interessaient (1 a 80 millicuries). La reproductibillte de la methode est tres bonne, le coefficient de variation pour une serie de 13 essais etant de 1,6 pour cent, quant a la precision relative, elle a ete evaluee a {+-} 1,3 pour cent. Pour terminer, nous donnons une description detaillee de l'appareillage utilise et du mode operatoire suivi. (auteurs)

  5. Analytic catalog for the use of the nuclear physicists; Repertoire analytique a l'usage des physiciens nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R.; Barloutaud, R.; Bernas, R.; Chaminade, R.; Cohen, R.; Conjeaud, M.; Cotton, E.; Faraggi, H.; Grjebine, T.; Laboulaye, H. de; Lehmann, P.; Leveque, A.; Levi, C.; Moreau, J.; Naggiar, V.; Olkowsky, J.; Papineau, L.; Papineau, L.; Prugne, P.; Schuhl, C.; Szteinsznaider, D.; Tzara, C.; Valladas, G. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires; Marty, N.; Renard, G. [College de France, Lab. de Chimie Nucleaire (France)

    1952-07-01

    The problem of the documentation in nuclear physics becomes constantly more complex. Every week brings its share of publications, always more numerous and more varied. To remedy to this problem, we tried, at the Nuclear Physics Services of the CEA, to give to the documentation the character of a collective and systematized work. The present report covers the literature appeared between January 1, 1950 and July 1, 1951. (Volume 1: CEA report number 120; Volume 2: CEA report number 184). (M.B.) [French] Le probleme de la documentation en physique nucleaire devient sans cesse plus complexe. Chaque semaine apporte son lot de publications, toujours plus nombreuses et plus diversifiees. C'est pour essayer de porter remede a cet etat de choses que nous avons essaye, au service de Physique Nucleaire du C.E.A., de donner a la documentation le caractere d'un travail collectif systematise. Le present rapport couvre la litterature parue entre le 1 Janvier 1950 et le 1 Juillet 1951. (Tome 1: Rapport CEA numero 120; Tome 2: Rapport CEA numero 184). (M.B.)

  6. ÉVALUATION MULTICRITÈRE D’ENTREPRISES PUBLIQUES DU RAIL

    OpenAIRE

    Mbangala, Mapapa; Colson, Gérard

    1998-01-01

    Les performances de dix entreprises publiques africaines du rail sont comparées entre elles au moyen des méthodes multicritères ELECTRE I, PROMETHEE II et JUDGES. Les 25 critères de premier niveau retenus sont regroupés d’abord en 8 familles capturant chacune un objectif de deuxième niveau. L’efficacité du service est mesurée par une fonction d’évaluation technicoéconomique regroupant les 4 premières familles. Son efficience est mesurée par une fonction d’évaluation où inter...

  7. Determination of the separation factor of uranium isotopes by gaseous diffusion; Determination des facteurs de separation des isotopes de l'uranium par diffusion gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Bilous, O; Counas, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    A 12-stage pilot separation cascade with a low output has been constructed to measure the separation factor of uranium isotopes by gaseous diffusion. The report describes some of the separation results obtained, and also provides information on the time necessary for equilibrium to be established and on the influence of various perturbations on the pressure profile in the cascade. (author) [French] Une cascade pilote de 12 etages de separation a faible debit a ete construite pour mesurer le facteur de separation des isotopes de l'uranium par diffusion gazeuse. Le rapport decrit certains des resultats de separation obtenus et fournit egalement des donnees sur les temps de mise en equilibre et l'influence de diverses perturbations sur le profil des pressions dans la cascade. (auteur)

  8. Relating to the higher sensitiveness of Frick ferrous sulphate dosimeter by the use of ortho-phenanthroline reagent (1960); Sensibilite accrue du dosimetre a sulfate ferreux de frick par l'utilisation du reactif a l'orthophenanthroline (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bouzigues, H; Schbdhauer, J; Brian, R; Messainguiral, L [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This paper describes a possible utilization of ferrous sulfate dosimeter by the use of ferrous o. phenanthroline as way of determination of the absorbed dose. The process was applied to the measure of the gamma radiation of radio-cobalt 60 and the relative middle values of the G{sub Fe{sup +}{sup +}} determined with a accuracy of {+-} 2,75 per cent in the range of rates of dose from 1000 to 30000 rad. The chief advantage concerns the coloured complex which is particularly stable. (author) [French] Cette note demontre les possibilites du dosimetre de Frick a sulfate ferreux en utilisant I'orthophenantroline ferreuse pour la mesure de la dose delivree. La methode mise au point pour la determination de la concentration en fer ferreux a ete utilisee pour la mesure de la dose delivree par une source de radiocobalt 60. Entre 1000 et 30000 rad, la valeur relative moyenne du rendement radiochimique a ete determinee a + 2,75 pour cent pres. L'avantage essentiel reside dans la stabilite du complexe colore forme apres irradiation. (auteur)

  9. ÉVOLUTION DE LA RÉPARTITION DES ÉCREVISSES EN FRANCE MÉTROPOLITAINE SELON LES ENQUÊTES NATIONALES MENÉES PAR LE CONSEIL SUPÉRIEUR DE LA PÊCHE DE 1977 À 2001

    Directory of Open Access Journals (Sweden)

    CHANGEUX T.

    2003-04-01

    Full Text Available Selon les enquêtes nationales menées par le Conseil supérieur de la pêche depuis 1977 en France métropolitaine, la répartition des espèces d’écrevisses montre que les espèces autochtones (Austropotamobius pallipes, Astacus astacus, Austropotamobius torrentium sont soit rares, soit en forte régression, alors que les espèces introduites (Orconectes limosus, Pacifastacus leniusculus, Procambarus clarkii, Astacus leptodactylus progressent. L’interdiction de transport vivant des espèces introduites, à l’exception d’A. leptodactylus, n’a pas enrayé le phénomène avec une accélération particulière de la progression de P. leniusculus ces cinq dernières années, certainement responsable de la recrudescence des cas de peste (Aphanomyces astaci. Les autres mesures favorisant les espèces autochtones, comme la limitation des prélèvements par pêche et les programmes de réintroduction, n’inversent pas la tendance. Il semble donc nécessaire de développer une politique de conservation centrée sur la préservation de l’habitat et le respect de certaines règles de prophylaxie à déterminer. Cela ne peut s’envisager que sur des bassins versants de petite surface facilement contrôlables s’il existe un fort engagement des autorités locales. Les 55 arrêtés de biotope, et surtout les 154 sites Natura 2000 avec leurs plans de gestion associés, apparaissent comme des voies prometteuses pour mettre en œuvre ce type d’actions en France. Le cas de l’île Corse, récemment colonisée par O. limosus, mériterait des mesures réglementaires particulières pour éviter que P. leniusculus et P. clarkii, ne la suivent dans l’avenir.

  10. Determination of plateau slope and activity using filter measurement results and W. Chauvenet's criterion (Mage II and Fortran IV calculation programmes); Determination de pente de palier et d'activite a partir de resultats de mesure filtres selon le critere de W. Chauvenet (programmes de calcul en Mage II et Fortran IV)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires, Departement d' Electronique Generale, Laboratoire de Metrologie de la Radioactivite

    1967-10-01

    In order to permit (at least partially) the objective comparison of plateau characteristics of gas-ionisation counters, plateaus which are obtained when each radioactive sample from normal LMR production is measured, a programme has been drawn up (on an electronic computer) comprising a processing section using least squares for obtaining the corrected plateaux and energies. With a view to an automatic operation of radio-measurement chains, the programme also comprises a preliminary section in which the statistical considerations of B. Peirce have been applied in the version better known as Chauvenet's criterion; this has been done with a view to eliminate measurement results which are dubious and even totally wrong. (author) [French] Pour rendre possibles (au moins partiellement) des comparaisons objectives entre paliers de caracteristiques de compteurs a ionisation gazeuse, paliers traces lors de la mesure de chaque etalon radioactif de la production courante du L.M.R., il a ete ecrit un programme (sur machine a calculer electronique) comportant une partie de traitement par les moindres carres en vue de la determination de pentes et d'activites corrigees. En prevision d'une exploitation automatique de cha es de radio-mesure, le programme comporte en outre une partie preliminaire dans laquelle des considerations statistiques dues a B. Peirce ont ete appliquees dans leur version plus connue sous le nom de critere de Chauvenet et ce dans le but d'une elimination des resultats de mesure suspects et meme veritablement aberrants. (auteur)

  11. The Scattering of Slow Neutrons from Hydrogen and Ethylene; Diffusion des neutrons lents par l'hydrogene et par l'ethylene; O rasseyanii medlennykh nejtronov vodorodom i ehtilenom; Dispersion de neutrones lentos por hidrogeno y etileno

    Energy Technology Data Exchange (ETDEWEB)

    Bally, D; Tarina, V; Todireanu, S [Institute of Atomic Physics, Bucharest (Romania)

    1963-01-15

    The angular distribution of 1.61 A wavelength neutrons scattered from hydrogen and ethylene has been measured. For ethylene the pressure was varied from 15 to 60 atm and for hydrogen from 60 to 110 atm. The investigated angular range was between 5''o and 90{sup o}. The experimental results obtained have been compared with the differential cross-section calculated using the Krieger-Nelkin formulae. (author) [French] Les auteurs ont mesure la distribution angulaire des neutrons ayant une longueur d'onde de 1,61 A diffuses par de l'hydrogene et par l'ethylene. Ils ont fait varier la pression de l'ethylene de 15 a 60 atm et celle de l'hydrogene de 60 a 110 atm. Le domaine angulaire etudie etait compris entre 5{sup o} et 90{sup o}. Les resultats des experiences ont ete compares aux sections efficaces differentielles calculees au moyen des formules de Krieger-Nelkin. (author) [Spanish] Los autores han medido la distribucion angular de neutrones de longitud de onda igual a 1,61 A, despersados por hidrogeno y etileno. En el caso del etileno, la presion vario de 15 a 60 atm y en el del higrogeno, de 60 a 110 atm. Los autores han explorado angulos comprendidos entre 5{sup o} y 90{sup o}. comparan los resultados experimentales obtenidos con el valor de la seccion eficaz diferencial calculado con ayuda de las formulas de Kriger-Nelkin. (author)

  12. Study of a device for the direct measurement of the fission gas pressure inside an in-pile fuel element; Etude d'un dispositif pour la mesure directe de la pression des gaz de fission a l'interieur d'un element combustible en pile

    Energy Technology Data Exchange (ETDEWEB)

    Lavaud, B; Uschanoff, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The fission gas pressure inside a fuel element made of a refractory fuel constitutes an important limiting factor for the burn-up. Although it is possible to calculate approximately the volume of gas produced outside the fuel during its life-time; it is nevertheless very difficult to evaluate the pressure since the volume allowed to the fission gases, as well as their temperature are known only very approximately. This physical value, which is essential for the technologist, can only be known by direct in-pile measurement of the pressure. The report describes the equipment which has been developed for this test. (authors) [French] La pression des gaz de fission a l'interieur d'un element combustible a combustible refractaire constitue une des limitations importantes du taux de combustion. Si on peut approcher par calcul la determination du volume, des gaz degages hors du combustible au cours de sa vie, il est par contre tres difficile d'evaluer la pression car le volume alloue aux gaz de fission et leur temperature sont tres mal connus. Cette donnee essentielle pour le technologue ne peut etre atteinte que par une mesure directe en pile de la pression. Le rapport decrit l'appareillage qui a ete mis au point pour cet essai. (auteurs)

  13. Gas loop - continuous measurement of thermal and fast neutron fluxes; Boucle a gaz - mesure continue de flux de neutrons thermiques et rapides

    Energy Technology Data Exchange (ETDEWEB)

    Droulers, Y; Pleyber, G; Sciers, P; Maurin, G [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    The measurement method described in this report can be applied both to thermal and fast neutron fluxes. A description is given of two practical applications in each of these two domains. This method is particularly suitable for measurements carried out on 'loop' type equipment. The measurement of the relative flux variations are carried out with an accuracy of 5 per cent. The choice of the shape of the gas circuit leaves a considerable amount of liberty for the adaptation of the measurement circuit to the experimental conditions. (authors) [French] La methode de mesure defrite dans ce rapport s1 applique aussi bien au flux de neutrons thermiques, qu'au flux de neutrons rapides. On donne la description de deux realisations pratiques dans chacun de ces domaines. Cette methode est particulierement adaptee a des mesures effectuees sur des dispositifs du type 'boucle'. La mesure des variations relatives de flux se fait avec une precision de 5 pour cent. Le choix de la configuration du circuit gazeux donne une grande souplesse dans l'adaptation du circuit de mesure aux conditions experimentales. (auteurs)

  14. Micro manometer and pitot tube for measuring the velocity distribution in a natural convection water stream between two vertical parallel plates (1961); Micromano metre et tube de pitot destines a l'exploration du profil de vitesse dans un ecoulement d'eau de convection naturelle entre deux plaques verticales paralleles (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Santon, L; Vernier, Ph [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-07-01

    For heat transfer studies in certain cases of cooling in swimming-pool type nuclear reactors, a knowledge of the distribution of the velocities between two heating elements is of prime importance. A Pitot tube and a micro-manometer have been developed for making these measurements on an experimental model. (authors) [French] Pour l'etude du transfert de chaleur dans certains cas de refroidissement des reacteurs nucleaires du type piscine, la connaissance de la repartition des vitesses entre deux elements chauffants est primordiale. On a mis au point un tube de Pitot et un micromanometre pour effectuer ces mesures sur une maquette experimentale. (auteurs)

  15. Fine structure and spectral index measurements in natural uranium - graphite lattices; Mesures fines dans des reseaux a graphite

    Energy Technology Data Exchange (ETDEWEB)

    Cogne, F; Journet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The experiments described in this report have been carried out for the most part in the critical facility MARIUS, and a few during the start up of the EDF-1 power reactor. The first part deals with the fine structure measurements made in various lattices and with their analysis. Integration over the neutron spectrum of the mono-kinetic disadvantage factor derived by the A.B.H method yields results in good agreement with the experiments. The second part deals with spectral indexes measurements (Pu/U, In/Mn) made at room temperature in MARIUS. Comparison are made of experiments with calculations using various thermalization models. Experiments carried out at higher temperatures in EDF-1 are also described. (authors) [French] Les mesures decrites dans ce rapport ont ete faites pour la plupart dans l'empilement critique MARIUS sur des reseaux a graphite-uranium naturel. Une premiere partie traite des mesures de structure fine faites dans differents reseaux et de leur interpretation. On montre en particulier qu'une integration sur le spectre d'un calcul monocinetique type A.B.H. rend bien compte des experiences. Dans une deuxieme partie, on donne les resultats de mesures d'indices de spectre Pu/U et In/Mn faites sur des reseaux froids a MARIUS et leur comparaison avec les differents modeles de calculs de thermalisation. On donne egalement les resultats de quelques mesures en temperature effectuees lors du demarrage du reacteur EDF-1. (auteurs)

  16. The System for Controlling Source and Special Nuclear Material at the Eurochemic Reprocessing Plant; Systeme de Controle des Matieres Nucleaires Brutes et Speciales a l'Usine de Traitement D'Eurochemic; Sistema kontrolya nad iskhodnym i spetsial'nym yadernym materialom na zavode evrokhimicheskoj kompanii po regeneratsii yadernogo topliva; Control de Materiales Nucleares Basicos y de Materiales Fisionables Especiales en la Planta de Regeneracion de la Eurochemic

    Energy Technology Data Exchange (ETDEWEB)

    Frenzel, W.; Schueller, W. [EUROCHEMIC, MOL (Belgium)

    1966-02-15

    Eurochemic is constructing a reprocessing plant near Mol (Belgium). The main characteristics of the plant and the different process steps are summarized. To maintain proper control of source and special nuclear material, the facilities of the company are divided into material balance areas. All transfers into and out of these areas are determined. Depending on their significance for the overall material balance, different precision requirements have been established according to a scale of significance which is briefly discussed. To adjust the book balance, physical inventories are periodically performed. The corresponding inventory procedures are outlined. The books used for nuclear materials accounting and the principles of the accounting system are summarized. (author) [French] La societe Eurochemic fait actuellement construire une usine de traitement chimique pres de Mol (Belgique). L'auteur indique succinctement les principales caracteristiques de l'usine et les differentes etapes du traitement. Pour assurer un controle correct des matieres nucleaires brutes et speciales, les installations d'Eurochemic sont divisees en secteurs de mesures. Tous les transferts entre ces secteurs de mesure sont determines quantitativement. Les mesures sont faites avec des degres de precision differents qui ont ete fixes en fonction de leur importance pour le bilan matieres general; les auteurs examinent brievement les criteres appliques a cette fin. Pour verifier le bilan, on procede periodiquement a des inventaires materiels. La facon dont sont menes ces inventaires est exposee dans ses grandes lignes. Les auteurs indiquent les livres utilises pour la comptabilite des matieres nucleaires et resument les principes du systeme comptable. (author) [Spanish] La compania Eurochemic esta construyendo una planta de regeneracion en Mol (Belgica). Los autores resumen las principales caracteristicas de la instalacion, y las distintas fases del proceso industrial. Para mantener un control

  17. FooPar

    DEFF Research Database (Denmark)

    Hargreaves, F. P.; Merkle, D.

    2013-01-01

    We present FooPar, an extension for highly efficient Parallel Computing in the multi-paradigm programming language Scala. Scala offers concise and clean syntax and integrates functional programming features. Our framework FooPar combines these features with parallel computing techniques. Foo......, results based on a empirical analysis on two supercomputers are given. We achieve close-to-optimal performance wrt. theoretical peak performance. Based on this result we conclude that FooPar allows programmers to fully access Scalas design features without suffering from performance drops when compared...

  18. Les écoulements fluviaux

    Directory of Open Access Journals (Sweden)

    Huguette VIVIAN

    1992-06-01

    Full Text Available Cette carte présente une image des principaux fleuves et de leurs affluents, ainsi que la situation des principales stations de mesure et des lames d’eau écoulées. Cette mesure des écoulements fluviaux, effectuée d’abord à l’aide des débits mesurés dans 400 stations hydrométriques choisies parmi les 800 du réseau national, a été éventuellement enrichie par des informations complémentaires.

  19. Structures and properties of (U,Pu)O{sub 2} containing non-active fission products. A simulation of irradiated nuclear fuel; Structure et proprietes de (U, Pu)O{sub 2} contenant des produits de fission sous forme inactive. Une simulation de combustible nucleaire irradie

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    We have made oxides with the same uranium and plutonium content, the same stoichiometry and the same fission product content as an oxide fuel (U{sub 0,8}PuO{sub 2})O{sub 1,96} after 2 per cent burn up. We have calculated the stoichiometry changes due to irradiation and checked the calculation by X rays parameters measurements. We have calculated and measured the contraction of the oxide lattice due to fission products in solid solution. Microprobe analysis of precipitates have been made and have lead to the identification of non metallic barium containing compounds and have shown the particular behaviour of molybdenum. Some physical properties have been measured especially the electrical resistivity, the thermal diffusivity and the vapour pressure of zirconium in solid solution. (author) [French] Nous avons fabrique des oxydes dont la composition en uranium et plutonium, la stoechiometrie et la teneur en produit de fission, sont identiques a celles d'un oxyde (U{sub 0,8}PuO{sub 2})O{sub 1,96} ayant subi 2 pour cent de combustion. Nous avons calcule les changements de stoechiometrie entraines par l'irradiation et controle ces calculs par des mesures de parametre. Nous avons calcule et mesure la contraction du reseau due aux produits de fissions solubles dans la matrice. Des analyses a la microsonde des precipites de produits de fission insolubles ont ete faites et ont conduit a l'identification de composes non metalliques contenant du baryum et a la mise en evidence du role particulier du molybdene. Certaines proprietes physiques ont ete mesurees sur ces composes, en particulier la resistivite electrique, la diffusivite thermique et la tension de vapeur du zirconium dissout dans la matrice. (auteur)

  20. Contribution to the study of the reactivity of graphite with respect to carbon dioxide and air; Contribution a l'etude de la reactivite du graphite vis-a-vis du gaz corbonique et de l'air

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-09-15

    The oxidation of nuclear-quality graphite by air and carbon dioxide has been studied at temperatures at which the reaction becomes measurable. These experiments have been carried out on graphites differing in the concentration and nature of their ash, and in their mode of preparation. The reaction velocities measured have been compared in an attempt to correlate these two factors. Ten types of graphite have thus been studied. Since the oxidation reactions are of the type gas-solid, their velocities have also been compared to the BET surface areas of the graphite studied and to the diameter distribution of the pores of this surface. The conclusion is that, even for these low impurity contents, the law relating the reaction velocity to the surface is masked by the impurities which appear to behave as preferential reaction sites. This has been shown by carrying out successive purifications on various types of graphite, which treatment results in an important decrease in the reactivity of all the samples studied. (author) [French] On a etudie l'oxydation de graphites de qualites nucleaires par l'air et par le gaz carbonique, a des temperatures telles que la reaction commence a etre mesurable. Ces essais ont porte sur des graphites differents aux points de vue de la concentration et de la nature des cendres, et differents par le mode de preparation. Les vitesses de reaction mesurees ont ete comparees afin de tenter de les relier a ces deux facteurs. Dix qualites de graphite ont ainsi ete etudiees. Les reactions d'oxydation etant des reactions gaz-solide, les vitesses ont ete egalement comparees aux surfaces specifiques B.E.T. des echantillons de graphite etudies et a la repartition par diametres des pores de cette surface. La conclusion est que, meme a ces teneurs faibles en impuretes, la loi de variation de la vitesse de reaction en fonction de la surface est masquee par les impuretes qui paraissent jouer le role de sites privilegies de reaction comme l'ont montre les

  1. Study of FeC1{sub 2} by neutron diffraction; Etude de Fe C1{sub 2} par diffraction de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Herpin, A.; Meriel, P. [Commissariat a l' Energie Atomique, Saclay (France)

    1959-07-01

    Magnetic measurements have shown that anhydrous ferrous chloride behaves as a metamagnetic at temperatures below 24 deg. K, in other words as an antiferromagnetic sensitive to the action of an external field of moderate strength. The aim of the neutron diffraction study is to determine precisely the arrangement of the magnetic moments, and to follow its evolution as a function of the applied field. (author) [French] Des mesures magnetiques ont montre que le chlorure ferreux anhydre se comporte comme un metamagnetique a une temperature inferieure a 24 deg. K, c'est a dire comme un antiferromagnetique sensible a l'action d'un champ exterieur modere. L'etude par diffraction de neutrons a pour buts de preciser la disposition des moments magnetiques et de suivre son evolution en fonction du champ applique. (auteur)

  2. Phosphorylation of Mycobacterium tuberculosis ParB participates in regulating the ParABS chromosome segregation system.

    Science.gov (United States)

    Baronian, Grégory; Ginda, Katarzyna; Berry, Laurence; Cohen-Gonsaud, Martin; Zakrzewska-Czerwińska, Jolanta; Jakimowicz, Dagmara; Molle, Virginie

    2015-01-01

    Here, we present for the first time that Mycobacterium tuberculosis ParB is phosphorylated by several mycobacterial Ser/Thr protein kinases in vitro. ParB and ParA are the key components of bacterial chromosome segregation apparatus. ParB is a cytosolic conserved protein that binds specifically to centromere-like DNA parS sequences and interacts with ParA, a weak ATPase required for its proper localization. Mass spectrometry identified the presence of ten phosphate groups, thus indicating that ParB is phosphorylated on eight threonines, Thr32, Thr41, Thr53, Thr110, Thr195, and Thr254, Thr300, Thr303 as well as on two serines, Ser5 and Ser239. The phosphorylation sites were further substituted either by alanine to prevent phosphorylation or aspartate to mimic constitutive phosphorylation. Electrophoretic mobility shift assays revealed a drastic inhibition of DNA-binding by ParB phosphomimetic mutant compared to wild type. In addition, bacterial two-hybrid experiments showed a loss of ParA-ParB interaction with the phosphomimetic mutant, indicating that phosphorylation is regulating the recruitment of the partitioning complex. Moreover, fluorescence microscopy experiments performed in the surrogate Mycobacterium smegmatis ΔparB strain revealed that in contrast to wild type Mtb ParB, which formed subpolar foci similar to M. smegmatis ParB, phoshomimetic Mtb ParB was delocalized. Thus, our findings highlight a novel regulatory role of the different isoforms of ParB representing a molecular switch in localization and functioning of partitioning protein in Mycobacterium tuberculosis.

  3. Phosphorylation of Mycobacterium tuberculosis ParB participates in regulating the ParABS chromosome segregation system.

    Directory of Open Access Journals (Sweden)

    Grégory Baronian

    Full Text Available Here, we present for the first time that Mycobacterium tuberculosis ParB is phosphorylated by several mycobacterial Ser/Thr protein kinases in vitro. ParB and ParA are the key components of bacterial chromosome segregation apparatus. ParB is a cytosolic conserved protein that binds specifically to centromere-like DNA parS sequences and interacts with ParA, a weak ATPase required for its proper localization. Mass spectrometry identified the presence of ten phosphate groups, thus indicating that ParB is phosphorylated on eight threonines, Thr32, Thr41, Thr53, Thr110, Thr195, and Thr254, Thr300, Thr303 as well as on two serines, Ser5 and Ser239. The phosphorylation sites were further substituted either by alanine to prevent phosphorylation or aspartate to mimic constitutive phosphorylation. Electrophoretic mobility shift assays revealed a drastic inhibition of DNA-binding by ParB phosphomimetic mutant compared to wild type. In addition, bacterial two-hybrid experiments showed a loss of ParA-ParB interaction with the phosphomimetic mutant, indicating that phosphorylation is regulating the recruitment of the partitioning complex. Moreover, fluorescence microscopy experiments performed in the surrogate Mycobacterium smegmatis ΔparB strain revealed that in contrast to wild type Mtb ParB, which formed subpolar foci similar to M. smegmatis ParB, phoshomimetic Mtb ParB was delocalized. Thus, our findings highlight a novel regulatory role of the different isoforms of ParB representing a molecular switch in localization and functioning of partitioning protein in Mycobacterium tuberculosis.

  4. Non-Destructive Methods for Determining Burn-Up in Nuclear Fuel; Methodes Non Destructives d'Evaluation du Taux de Combustion dans le Combustible Nucleaire; Metody opredeleniya vygoraniya v yadernom toplive bez razrusheniya obraztsa; Metodos No Destructivos para Determinai el Grado de Combustion de los Elementos Combustibles Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    McGonnagle, W. J. [Illinois Institute of Technology, Chicago, IL (United States)

    1966-02-15

    is of secondary importance and the cooling time is unimportant. Also, there is more precise nuclear data for the stable fission products. Of the stable isotopes produced during the fission process, zirconium, molybdenum, ruthenium, and neodymium appear to be the most useful. The proposed non-destructive methods using stable isotopes will be discussed. (author) [French] Il est a la fois utile et souhaitable d'utiliser des methodes non destructives pour proceder a la mesure quantitative du taux de combustion des elements combustibles d'un reacteur nucleaire. L'ideal serait de pouvoir analyser le combustible a l'aide d'une methode ne necessitant pas de renseignements particuliers sur les spectres des neutrons, le schema d'irradiation ou le temps de refroidissement. Les isotopes radioactifs et les isotopes stables resultant du processus de fission qui sont presents dans un element combustible irradie caracterisent son irradiation. Malheureusement, que l'analyse soit effectuee au moyen de methodes destructives ou non destructives, les resultats obtenus varient en fonction du spectre de neutrons, du schema d'irradiation et du temps de refroidissement. Deplus, l'absence de donnees nucleaires precises, comme les valeurs des section efficaces, influe sur tous les calculs qui peuvent etre effectues. L'analyse non destructive est egalement genee par la presence de champs de rayonnements intenses qui augmentent le bruit de fond. Il est difficile d'etablir des normes utiles et realistes. Bien que, dans l'etat actuel de la technique, les methodes non destructives n'aient pas toute la precision et l'exactitude voulues, elles presentent neanmoins un grand interet' notamment dans les cas ou il faut obtenir rapidement et economiquement une valeur approximative du taux de combustion. Plusieurs methodes non destructives d'evaluation du taux de combustion sont actuellement appliquees, a l'etude ou en projet. Plusieurs types de spectrometres sont utilises pour la mesure du rayonnement

  5. Epuration des eaux usées de raffinerie par le procédé biologique des lits bactériens. Problèmes pratiques de l'exploitation Purifying Refinery Waste Water by the Bacterial Bed Biological Process. Practical Operational Problems

    Directory of Open Access Journals (Sweden)

    Leising M.

    2006-11-01

    Full Text Available Le traitement des eaux de raffinerie par le procédé des Iits bactériens constitue une solution intéressante. Néanmoins, il subsiste actuellement des problèmes pratiques d'exploitation, en particulier la tendance au colmatage des lits bactériens existants qui résulte d'un encrassement incontrôlé des garnissages en vrac. Après étude, il est confirmé que les hydrocarbures, les matières en suspension contenus dans l'effluent et une mauvaise évacuation de la biomasse sont à l'origine du problème. L'examen des possibilités de lutte contre ce phénomène permet de distinguer des mesures curatives et des mesure préventives. Les mesures curatives qui consistent à régénérer le garnissage par augmentation de la charge hydraulique, nettoyage chimique, ou nettoyage manuel ne donnent pas entière satisfaction. Parmi tes mesures préventives, l'une des méthodes consiset à réduire la charge polluante de l'effluent : les eaux usées phénolées sont dessalées, les eaux de désulfuration du gas oil (DGO et fluid cracking catalytic (FCC sont strippées, les soudes sont réinjectées dans le brut, les huiles récupérées juste en aval de leur rejet, les traitements primaires sont optimisés, notamment par installation de racleurs et de tambours oléophiles sur les séparateurs API et par un meilleur choix de floculants. Néanmoins, l'expérience montre que cette méthode ne permet que de retarder l'échéance du colmatage. Le meilleur moyen de lutte réside dans le choix du matériau de garnissage, ainsi que le montrent les essais pilotes comparatifs réalisés par l'Institut National de Recherche Chimique Appliquée (lRCHA et Compagnie Française de Raffinage (CFR. Ces essais, qui ont portés sur l'évolution de la densité du garnissage, les performances épuratoires et la qualité des boues montrent que le Cloisonyle, garnissage tubulaire, est probablement le matériau le mieux adapté. Refinery waste-water treatment by trickling

  6. Mesure de la vitesse d'infiltration des eaux dans le sol : Cas des sols ...

    African Journals Online (AJOL)

    SARAH

    30 avr. 2016 ... Pour ceux, il est nécessaire d'opter pour une agriculture moderne ... à une telle agriculture. Mots clés : mesure, vitesse, infiltration, sols, pollutions, eau, Niari, Congo .... une porosité tubulaire d'origine biologique. Toutes ces.

  7. Isotopic analysis of H{sub 2}, HD, D{sub 2} mixtures and analysis of ortho-para-hydrogen mixtures by gas chromatography; Dosages par chromatographie en phase gazeuse de melanges d'hydrogene, d'hydrogene deutere, de deuterium et de melanges ortho-para-hydrogene

    Energy Technology Data Exchange (ETDEWEB)

    Botter, F; Perriere, G de la; Tistchenko, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This communication describes the present situation concerning the possibilities of vapor phase chromatography for the separation and analysis of mixtures of H{sub 2}, HD and D{sub 2} and of ortho- and para-hydrogen mixtures. Separation factors for physical adsorption of the various varieties of hydrogen have been deduced from chromatograms and have also been measured directly with a static method - the agreements is good. (author) [French] Le present rapport decrit diverses possibilites qu'offre la chromatographie gazeuse d'elution en ce qui concerne le dosage des melanges H{sub 2}, HD, D{sub 2} et des varietes ortho et para de l'hydrogene. On a calcule, a partir des chromatogrammes obtenus, les facteurs de separation par adsorption physique des differentes varietes d'hydrogene, et compare aux facteurs de separation determines par mesure directe. (auteur)

  8. The 'Pole Nucleaire Bourgogne' for developing the nuclear components industry

    International Nuclear Information System (INIS)

    Kottmann, G.

    2012-01-01

    The 'Pole Nucleaire Bourgogne' (PNB) is a high-technology and heavy industries cluster in Burgundy with an international calling. It aims at innovating, educating and federating in order to place the French nuclear industry in a leading position. PNB gathers 76 small-, and medium-sized enterprises, most of them operating in the metal sector, in design and in the control/measuring sector. The aim of PNB is to make enterprises work and cooperate on specific topics according to their sectors of activities and their skills. PNB has identified 3 domains of strategical innovations: -) ecological manufacturing and durability of heavy components, -) controls for high performance components, and -) maintenance and dismantling techniques in hostile environments. The various industry sectors represented in PNB allows a cross-fertilization between high-tech industries (aeronautics, energy, transportation)

  9. Mesure magnétique du sextupôle rotatif no.1-2083

    CERN Document Server

    Chritin, R; Patron, G; CERN. Geneva. SPS and LEP Division

    1998-01-01

    Lorsque cet aimant nous a été livré afin d'être soumis à un certain nombre de mesures, ses caractéristiques connues se limitaient à celles situées dans l'annexe 1. Il correspond à des sextupôles, INT 2170254 AB L orientables récupérés de l'ancienn

  10. Fast neutron dosimetry and spectrometry using radioactivation (1963); Dosimetrie et spectrometrie des neutrons rapides par radioactivation (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lamberieux, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The author first recalls rapidly a few generalities concerning induced radioactivity detectors and gives, in an appendix, tables summarizing the properties of detector elements which may be used in radioprotection. The excitation functions found in the literature and also given. The technological characteristics of the detectors used are given, together with the counting methods. The many advantages of activation dosimetry for strong or periodic neutron fluxes and for those in the presence of {gamma}-radiation are stressed. The main problem in activation dosimetry is, however, the calculation of the dose absorbed from the results of the measurements. It is shown how the dose is expressed, fairly accurately, as a function of the radioactivities induced in a series of detectors. As an example, the spectrometry and the dosimetry of the neutron flux emitted by a Po-Be source are presented. (author) [French] L'auteur fait d'abord un bref rappel des generalites sur les detecteurs a radioactivite induite, accompagne, en annexe, des tableaux resumant les proprietes d'elements detecteurs utilisables en radioprotection. Les fonctions d'excitation trouvees dans la litterature y sont egalement annexees. On donne ensuite les caracteristiques technologiques des detecteurs employes ainsi que les methodes de comptage utilisees. On souligne les nombreux avantages de la dosimetrie par activation dans les flux de neutrons intenses ou periodiques et en presence de rayonnement {gamma}. Il reste que le probleme central de la dosimetrie par activation est le calcul de la dose absorbee a partir des resultats de mesure. On montre comment la dose s'exprime, de maniere approchee, en fonction des radioactivites induites dans une serie de detecteurs. A titre d'exemple, la spectrometrie et la dosimetrie du flux de neutrons emis par une source de Po-Be sont presentees. (auteur)

  11. Association entre le travail par quarts et l’obésité chez les hommes dans le nord-est de l’Ontario

    Directory of Open Access Journals (Sweden)

    Anne Grundy

    2017-01-01

    Full Text Available Introduction : Même si certaines études suggèrent une association entre le travail par quarts et l’obésité, peu sont fondées sur la population ou tiennent compte de divers horaires de travail par quarts. L’obésité étant associée à plusieurs problèmes de santé chroniques, il est important de comprendre quelles formes de travail par quarts ont une incidence sur elle et d’effectuer des travaux permettant d’évaluer de façon plus détaillée l’exposition au travail par quarts. Méthodologie : Au moyen d’une régression logistique polytomique multivariée, nous avons étudié l’association entre le travail par quarts (de soir ou nuit, par quarts ou autre type de rotation et le surpoids et l’obésité, en fonction d’une mesure transversale de l’indice de masse corporelle chez 1 561 hommes. Ces hommes avaient déjà servi de témoins dans une étude cas-témoins sur le cancer de la prostate menée dans le nord-est de l’Ontario de 1995 à 1999. Nous avons obtenu l’information sur leurs antécédents de travail (notamment sur le travail par quarts, leur taille et leur poids à partir de données autodéclarées recueillies par questionnaire. Résultats : Nous avons observé une association entre le fait d’avoir déjà travaillé par quarts (par opposition au fait de n’avoir jamais travaillé par quarts et le surpoids (RC [rapport de cotes] = 1,34; IC [intervalle de confiance] à 95 % : 1,05 à 1,73 ainsi que l’obésité (RC = 1,57; IC à 95 % : 1,12 à 2,21. Nous avons également observé des associations statistiquement non significatives avec le fait d’avoir déjà travaillé (par opposition au fait de n’avoir jamais travaillé de façon permanente selon un quart de soir ou de nuit. Nous avons par ailleurs observé une tendance à la hausse statistiquement significative en ce qui concerne le risque de surpoids et d’obésité en fonction de la durée du travail par quarts. Conclusion : Tant l

  12. éolien- photovoltaïque- diesel

    African Journals Online (AJOL)

    AKA BOKO

    reach the best performances. ..... et ce convertisseur devra être en mesure de délivrer une puissance ... par le courant débiter par chacun des systèmes, le contrôle de leur charge est ... Figure 8 : Modélisation et gestion du système hybride.

  13. ParA and ParB coordinate chromosome segregation with cell elongation and division during Streptomyces sporulation

    Science.gov (United States)

    Donczew, Magdalena; Mackiewicz, Paweł; Wróbel, Agnieszka; Flärdh, Klas; Zakrzewska-Czerwińska, Jolanta

    2016-01-01

    In unicellular bacteria, the ParA and ParB proteins segregate chromosomes and coordinate this process with cell division and chromosome replication. During sporulation of mycelial Streptomyces, ParA and ParB uniformly distribute multiple chromosomes along the filamentous sporogenic hyphal compartment, which then differentiates into a chain of unigenomic spores. However, chromosome segregation must be coordinated with cell elongation and multiple divisions. Here, we addressed the question of whether ParA and ParB are involved in the synchronization of cell-cycle processes during sporulation in Streptomyces. To answer this question, we used time-lapse microscopy, which allows the monitoring of growth and division of single sporogenic hyphae. We showed that sporogenic hyphae stop extending at the time of ParA accumulation and Z-ring formation. We demonstrated that both ParA and ParB affect the rate of hyphal extension. Additionally, we showed that ParA promotes the formation of massive nucleoprotein complexes by ParB. We also showed that FtsZ ring assembly is affected by the ParB protein and/or unsegregated DNA. Our results indicate the existence of a checkpoint between the extension and septation of sporogenic hyphae that involves the ParA and ParB proteins. PMID:27248800

  14. The 1989 annual report of the Institut de Physique Nucleaire-Orsay

    International Nuclear Information System (INIS)

    1989-01-01

    The activity report of the Institut de Physique Nucleaire (Orsay-France) from 1 Sep 1988 to 1 Aug 1989 is presented. Theoretical and experimental investigations were carried out in the following fields: light and medium exotic nuclei, on line spectroscopy, discrete high spin states, new radioactivities, thermal fission, detection systems, giant resonances, high excitation energy structure, reaction mechanisms at energies below 10 MeV/u and at 200 MeV/u and their evolution between 10 and 100 MeV/u, meson production, transfer reactions, spin modes in nuclei, dibaryonic resonances, inelastic scattering of polarized protons. Research programs in the field of radiochemistry and relating to inter-disciplinary fields are included. The activities involving teaching, the lists of publications conferences, seminars and theses are presented [fr

  15. New recording methods and electromechanical analysis; Nouvelles methodes d'enregistrement et de depouillement electromecanique des numerations de particules

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, R.; Bonpas, M.; Legrand, J.P. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    The measurement that the most often occurs in nuclear physics are of the numerations of pulses representing the transit of a particle in a detector that can be a Geiger counter, a photomultiplier or a pulse chamber. We studied and constructed an electromagnetic recorder who permits to get automatically and without calculation: 1) the activity of a radioelement according to the time; 2) the curve of decrease of a radioelement and its period; 3) any curves of growth or decrease; 4) the activity, at any instant, of a neutron detector; 5) the neutron densities ratios in several points by the method of the detectors. (M.B.) [French] Les mesures qui se presentent le plus souvent en physique nucleaire sont des numerations d'impulsions representant le passage d'une particule dans un detecteur qui peut etre un compteur de Geiger, un photomultiplicateur ou une chambre a impulsions. Nous avons etudie et construit un enregistreur electromagnetique qui permet d'obtenir automatiquement et sans calcul: 1) l'activite d'un radioelement en fonction du temps; 2) la courbe de decroissance d'un radioelement et sa periode; 3) des courbes quelconques de croissance ou de decroissance; 4) l'activite, rapportee a un instant quelconque, d'un detecteur de neutrons; 5) les rapports des densites de neutrons en plusieurs points par la methode des detecteurs. (M.B.)

  16. New recording methods and electromechanical analysis; Nouvelles methodes d'enregistrement et de depouillement electromecanique des numerations de particules

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, R; Bonpas, M; Legrand, J P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    The measurement that the most often occurs in nuclear physics are of the numerations of pulses representing the transit of a particle in a detector that can be a Geiger counter, a photomultiplier or a pulse chamber. We studied and constructed an electromagnetic recorder who permits to get automatically and without calculation: 1) the activity of a radioelement according to the time; 2) the curve of decrease of a radioelement and its period; 3) any curves of growth or decrease; 4) the activity, at any instant, of a neutron detector; 5) the neutron densities ratios in several points by the method of the detectors. (M.B.) [French] Les mesures qui se presentent le plus souvent en physique nucleaire sont des numerations d'impulsions representant le passage d'une particule dans un detecteur qui peut etre un compteur de Geiger, un photomultiplicateur ou une chambre a impulsions. Nous avons etudie et construit un enregistreur electromagnetique qui permet d'obtenir automatiquement et sans calcul: 1) l'activite d'un radioelement en fonction du temps; 2) la courbe de decroissance d'un radioelement et sa periode; 3) des courbes quelconques de croissance ou de decroissance; 4) l'activite, rapportee a un instant quelconque, d'un detecteur de neutrons; 5) les rapports des densites de neutrons en plusieurs points par la methode des detecteurs. (M.B.)

  17. Par Pond water balance

    International Nuclear Information System (INIS)

    Hiergesell, R.A.; Dixon, K.L.

    1996-06-01

    A water budget for the Par Pond hydrologic system was established in order to estimate the rate of groundwater influx to Par Pond. This estimate will be used in modeling exercises to predict Par Pond reservoir elevation and spillway discharge in the scenario where Savannah River water is no longer pumped and discharged into Par Pond. The principal of conservation of mass was used to develop the water budget, where water inflow was set equal to water outflow. Components of the water budget were identified, and the flux associated with each was determined. The water budget was considered balanced when inflow and outflow summed to zero. The results of this study suggest that Par Pond gains water from the groundwater system in the upper reaches of the reservoir, but looses water to the groundwater system near the dam. The rate of flux of groundwater from the water table aquifer into Par Pond was determined to be 13 cfs. The rate of flux from Par Pond to the water table aquifer near the dam was determined to be 7 cfs

  18. suPAR

    DEFF Research Database (Denmark)

    Hodges, Gethin W; Bang, Casper N; Wachtell, Kristian

    2015-01-01

    The fundamental role of inflammation in cardiovascular disease (CVD) has prompted interest in numerous biomarkers that detect subclinical levels of inflammation. Soluble urokinase plasminogen activator receptor (suPAR) is a novel biomarker that correlates significantly with cardiovascular events ...... comprehensive review of suPAR in CVD and explore its function and usefulness in predicting cardiovascular events....

  19. C9.A/14 steelwork joints de poutres par plaque frontale : assemblages par gousset

    CERN Document Server

    2015-01-01

    Les Tables de résistances ultimes des assemblages boulonnés par plaque frontale et par gousset, complétées par une description des modèles de calcul et des exemples d’application, ont pour but de faciliter la tâche de l'ingénieur et du constructeur. Cette première partie C9.A/14 contient les chapitres suivants: - Joints de poutres par plaque frontale en acier S235 et S355 - Assemblages par gousset en acier S235 et S355 Les Tables contiennent des données relatives à la géométrie ainsi que les valeurs de calcul correspondantes des résistances ultimes des assemblages ; elles remplacent le chapitre « Assemblages par plaques frontales et boulons HR » des anciennes Tables C9.1 de 1983 / 2002. Le calcul de ces assemblages par plaque frontale est basé sur les hypothèses du modèle de la méthode des composants décrite dans la norme SN EN 1993-1-8. Les vérifications sont effectuées selon la norme SIA 263:2013. Les assemblages par gousset remplacent les assemblages par double cornière, (telle...

  20. High-sensitivity gamma spectroscopy for extended sources. Application to activity measurements on the human body, on glass, and on soil; Spectrographie gamma a grande sensibilite pour sources etendues. Application a la mesure de l'activite du corps humain, du verre et du sol

    Energy Technology Data Exchange (ETDEWEB)

    Jouve, B

    1962-07-01

    The measurement and location by gamma spectroscopy of human body internal contaminations at maximum permissible levels, and, in certain cases, at lower activities such as that due to {sup 40}K was investigated. The characteristics of the high-sensitivity apparatus used are given, and several assemblies using large-volume NaI(Tl) scintillators are described. The relatively light shielding required for natural radioactivity permitted construction of mobile assembly. Conditions of use are described, and the results are given. All gamma emitting elements were measured in 15 min at levels lower than the tolerance dose. Gamma spectroscopy was also used to determine fission products in the earth and to study radioactive elements in the presence of other emitters. (author) [French] La spectrographie gamma du corps humain permet la mesure et la localisation des contaminations internes au niveau des doses de tolerance et, dans certains cas, celle d'activites plus faibles comme la radioactivite naturelle due principalement au potassium 40. Les caracteristiques des appareils a grande sensibilite permettant ces mesures sont exposees et on decrit plusieurs realisations originales utilisant un scintillateur NaI(Tl) de grand volume. L'epaisseur du blindage a ete limitee a 5 cm de plomb, ainsi, pour une protection suffisante contre les rayonnements ambiants, les appareils sont relativement legers et l'une des realisations a pu etre installee dans un laboratoire mobile. Les conditions d'utilisation (mouvement propre, etalonnage) et les resultats obtenus sont donnes; tous les radioelements emetteurs gamma sont mesurables en 15 minutes a un niveau inferieur a la dose de tolerance. On presente enfin des applications a la spectrographie gamma d'echantillons volumineux (poudres ou liquides) et de tres faible activite: elles interessent des domaines tres varies comme, par exemple, la geophysique (etude des retombees radioactives) ou l'industrie chimique (dosage du potassium dans les

  1. New Instruments and Principles for the Dimensional Measurement and Measurement of Spacing of Reactor Components; Nouveaux Instruments et Procedes de Mesure des Dimensions et de l'Espacement des Elements d'un Reacteur; Novye pribory i printsipy izmereniya razmerov i raspolozheniya komponentov reaktora; Nuevos Instrumentos y Principios para Medir las Dimensiones y la Separacion Entre Componentes de Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, P. [Institut Dr. Foerster, Reutlingen, Federal Republic of Germany (Germany)

    1965-09-15

    instrument for reactor components are discussed. Special attention is given to the possibility of using a small and versatile pick-up by means of manipulators in the ''hot'' zones and on ''hot'' materials. The increase of surface roughness with increasing irradiation dose is discussed. (author) [French] Full text: L'auteur presente les problemes de mesure de l'epaisseur de feuilles et des parois de tubes et recipients en aciers austenitiques ou en metaux non ferreux. Deux methodes de mesure des epaisseurs sans contact sont discutees: la mesure, par courants de Foucault, de l'epaisseur de feuilles et des parois de recipients en metaux non ferreux ou en aciers austenitiques, au moyen de bobines se deplacant le long des pieces a examiner: la mesure, par courants de Foucault, de l'epaisseur des parois de tubes, au moyen de bobines dans lesquelles se deplacent les pieces a examiner. L'auteur decrit des instruments appropries et le mode d'utilisation. Il discute egalement la mesure de l'epaisseur des parois de parties constitutives de reacteurs, en metaux non ferreux, par la 'methode de la bille magnetique' et explique le principe de ce nouveau type de mesure et son domaine d'utilisation - notamment pour les mesures par points; il decrit un instrument approprie. L'auteur examine la mesure des revetements non magnetiques de materiaux magnetiques; il explique les principes de mesure (methodes fondees sur les champs magnetiques des courants continus et des courants alternatifs) et decrit des instruments de mesure de revetements non magnetiques dont l'epaisseur varie entre 3 {mu}m et 20 mm. Il expose le probleme special de la mesure des depots de stellite sur les parois en aciers ferritiques des cuves de reacteurs. La mesure des revetements non conducteurs de metaux non ferreux est etudiee. Le memoire explique le principe de mesure (courants de Foucault). Il decrit un instrument approprie et donne des exemples de mesures typiques. L'auteur examine egalement la mesure sans contact, en

  2. Analysis and separation of boron isotopes; Analyse et separation des isotopes du bore

    Energy Technology Data Exchange (ETDEWEB)

    Perie, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-11-01

    The nuclear applications of boron-10 justify the study of a method of measurement of its isotopic abundance as well as of very small traces of boron in different materials. A systematic study of thermionic emission of BO{sub 2}Na{sub 2}{sup +} has been carried out. In the presence of a slight excess of alkalis, the thermionic emission is considerably reduced. On the other hand, the addition of a mixture of sodium hydroxide-glycerol (or mannitol) to borax permits to obtain an intense and stable beam. These results have permitted to establish an operative method for the analysis of traces of boron by isotopic dilution. In other respects, the needs of boron-10 in nuclear industry Justify the study of procedures of separation of isotopes of boron. A considerable isotopic effect has been exhibited in the chemical exchange reaction between methyl borate and borate salt in solution. In the case of exchange between methyl borate and sodium borate, the elementary separation factor {alpha} is: {alpha}=(({sup 11}B/{sup 10}B)vap.)/(({sup 11}B/{sup 10}B)liq.)=1.03{sub 3}. The high value of this elementary effect has been multiplied in a distillation column in which the problem of regeneration of the reactive has been resolved. An alternative procedure replacing the alkali borate by a borate of volatile base, for example diethylamine, has also been studied ({alpha}=1,02{sub 5} in medium hydro-methanolic with 2,2 per cent water). (author) [French] Les applications nucleaires du bore 10 justifient l'etude d'une methode de mesure de son abondance isotopique dans divers materiaux ainsi que le dosage de tres faibles traces de bore. Une etude systematique de l'emission thermoionique de BO{sub 2} Na{sub 2}{sup +} a ete effectuee. En presence d'un leger exces d'alcalins, l'emission thermoionique est considerablement reduite. Par contre l'addition au borax d'un melange soude-glycerol (ou mannitol) permet d'obtenir un faisceau stable et intense. Ces resultats ont permis d'etablir un mode

  3. Spectral content of seismic movements produced by underground nuclear explosions; Contenu spectral des mouvements seismiques dus aux explosions nucleaires souterraines

    Energy Technology Data Exchange (ETDEWEB)

    Albaret, A; Duclaux, F [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    After a summary of available data, both theoretical and experimental, concerning the spectral content of seismic movements, a description is given of the experiments carried out during the French nuclear explosions in the Sahara, and of the results obtained on the volume waves. A comparison is then made with certain American results. A new method is described for studying the amplitude spectra; it has made it possible to show that the amount of low frequencies in the spectrum increases with the power of the explosion, and decreases with the distance to the zero point and with the filtering effect of the weathered zone. A calculation is then made of the low cut-off ground filter, this giving a better representation of the initial seismic phenomenon. (authors) [French] Apres avoir resume les connaissances disponibles, aussi bien theoriques qu'experimentales, sur le contenu spectral des mouvements seismiques, on decrit les experiences effectuees a l'occasion des explosions nucleaires francaises du Sahara et les resultats obtenus sur les ondes de volume. Puis on les compare avec certains resultats americains. On decrit une nouvelle methode d'etude des spectres d'amplitudes qui montre que le spectre est d'autant plus riche en basses frequences que la puissance de l'explosion est grande, que la distance au point zero est faible et qu'il est moins filtre par la zone alteree superficielle. Puis on calcule le filtre terrain coupe-bas qui permet de donner une representation plus fidele du phenomene seismique initial. (auteurs)

  4. New developments in the analysis and measurement of thicknesses by {beta}-particle excitation of X fluorescent rays; Nouveaux developpements de l'analyse et de la mesure des epaisseurs par excitation des raies de fluorescence X au moyen de particules {beta}; Novye usovershenstvovaniya analiza i izmereniya plotnosti putem vozbuzhdeniya fluorestsiruyushchikh spektrov rentgenovskogo lucha beta-chastitsami; Nuevos adelantos en el analisis y la medicion de espesores mediante la excitacion de rayos X por particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France); Seibel, G [Institut de Recherches de la Siderurgie, St-Germain-en-Laye (France)

    1962-01-15

    The method of analysing and measuring the thickness of deposits by {beta}-X fluorescence which we previously described has been further developed. Using Pm{sup 147} and Kr{sup 85} sources, it is possible to reduce the background observed with Sr{sup 90}. We quote the results obtained for various thickness measurements of metal deposits, an analysis of the solutions, and the continuous measurement of calcium and iron in core samples. We describe experiments made for analysis of the X-radiation by crystal. (author) [French] Le procede d'analyse et de mesure des epaisseurs de depots par fluorescence {beta}-X que nous avons precedemment decrit a fait l'objet de nouveaux developpements. L'emploi de sources de {sup 147}Pm et de {sup 85}Kr permet de reduire le bruit de fond que l'on observe avec le {sup 90}Sr. Nous donnons les resultats obtenus pour diverses mesures d'epaisseurs de depots metalliques, l'analyse des solutions et la mesure en continu du calcium et du fer dans les carottes de minerais. Nous decrivons les essais effectues en vue d'analyser le rayonnement X au moyen d'un cristal. (author) [Spanish] Los autores han introducido nuevos perfeccionamientos en su procedimiento de analisis y de medicion de espesores de depositos por fluorescencia de rayos X excitada por particulas beta. La utilizacion de fuentes de {sup 147}Pm y de {sup 85}Kr permite reducir la actividad de fondo que se observa empleando {sup 90}Sr. Los autores exponen los resultados obtenidos en materia de mediciones de espesores de depositos metalicos, analisis de soluciones y medicion continua del calcio y del hierro en muestras de minerales extraidas por sondeo. Tambien describen los ensayos realizados con miras a analizar los rayos X por medio de un cristal. (author) [Russian] Protsess analiza i izmereniya plotnosti sloev putem fluorestsiruyushchikh beta- i rentgenovskikh luchej, kotoryj opisyvalsya nami ran'she, byl predmetom novykh usovershenstvovanij. Ispol'zovanie istochnikov prometeya-147 i

  5. Contribution to the study of radio toxicity of aromatic and medicinal plants using solid state nuclear track detectors; Contribution a l etude de la radio toxicite des plantes aromatiques et medicinales au moyen des detecteurs solides de traces nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Mortassim, A; Misdaq, M A; Naaman, A

    2009-07-01

    The concentrations of uranium (238 U), thorium (232 Th), radon (222 Rn) and thoron (220 Rn) were measured in twenty aromatic and medicinal plants in {sup f}ind a new method based on using solid state nuclear track detectors type Cr-39 and Rs-115. He emerges from this study that the verbena and salvia have higher levels of uranium (radon) higher than that of other plants while the leaves of olive and saturja have concentrations of thorium (thoron) higher than other plants therefore radio toxicity of these plants is higher than that of others and may pose a radiological hazard if the masses are incorporated by consumers high. [French] Les concentrations en uranium (238U), thorium (232Th), radon (222Rn), et thoron (220Rn) ont ete mesurees dans vingt plantes aromatiques et medicinales en utilsant une nouvelle methode basee sur l utilisation des detecteurs solides de traces nucleaires de types CR-39 et LR-115. Il en sort de cette etude que la verveine et la salvia presentent des teneurs en uranium (radon) superieurs a celle des autres plantes alors que les feuilles d olivier et la saturja presentent des concentrations en thorium (thoron) plus elevee que celles des autres plantes par consequent la radio toxicite de ces plantes est superieure a celles des autres et peuvent presenter un risque radiologique si les masses incorporees par les consommateurs sont elevees.

  6. Enseignement technique/Technical Training

    CERN Multimedia

    1998-01-01

    Conception électronique/Electronic Design - Conception assistée par ordinateur/Computer-Aided Design - PCAD13 CADENCE - LabVIEW - Automatisme et mesures/Automation & Measures - Fieldbuses/Divers/Miscellaneous

  7. Free diffusion of translation of macromolecules in solution with the rayleigh interferometer; Diffusion libre de translation des macromolecules en solution, par interferometrie de rayleigh

    Energy Technology Data Exchange (ETDEWEB)

    Leger, J J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The aim of this study is to develop a rapid and accurate measurement, with the Rayleigh interferometer, of the free diffusion coefficient of translation of macromolecules in solution. After having explained the choice of a diffusion cell with laminar lateral flow, and explained the principle of the Rayleigh interferometer, a semi-automatic technique of free diffusion are then introduced. Solutions are proposed for systems composed of two or three components, such as biopolymers. The paper ends by drafting the possible treatment of recorded experimental data by means of electronic computer. (author) [French] Cette etude a ete entreprise pour mettre au point une methode precise et rapide de mesure, par interferometre de Rayleigh, du coefficient de diffusion libre de translation des macromolecules en solution. Apres avoir justifie le choix d'une cellule de diffusion a ecoulement laminaire lateral et explique le principe de l'interferometre de Rayleigh, l'auteur decrit une technique semi-automatique d'enregistrement des cliches d'interference. Il introduit ensuite les equations differentielles de diffusion libre et propose des solutions pour les systemes a deux et trois composants applicables aux biopolymeres. L'article se termine par une esquisse concernant le traitement des donnees experimentales enregistrees au moyen du calcul electronique. (auteur)

  8. High-sensitivity gamma spectroscopy for extended sources. Application to activity measurements on the human body, on glass, and on soil; Spectrographie gamma a grande sensibilite pour sources etendues. Application a la mesure de l'activite du corps humain, du verre et du sol

    Energy Technology Data Exchange (ETDEWEB)

    Jouve, B

    1962-07-01

    The measurement and location by gamma spectroscopy of human body internal contaminations at maximum permissible levels, and, in certain cases, at lower activities such as that due to {sup 40}K was investigated. The characteristics of the high-sensitivity apparatus used are given, and several assemblies using large-volume NaI(Tl) scintillators are described. The relatively light shielding required for natural radioactivity permitted construction of mobile assembly. Conditions of use are described, and the results are given. All gamma emitting elements were measured in 15 min at levels lower than the tolerance dose. Gamma spectroscopy was also used to determine fission products in the earth and to study radioactive elements in the presence of other emitters. (author) [French] La spectrographie gamma du corps humain permet la mesure et la localisation des contaminations internes au niveau des doses de tolerance et, dans certains cas, celle d'activites plus faibles comme la radioactivite naturelle due principalement au potassium 40. Les caracteristiques des appareils a grande sensibilite permettant ces mesures sont exposees et on decrit plusieurs realisations originales utilisant un scintillateur NaI(Tl) de grand volume. L'epaisseur du blindage a ete limitee a 5 cm de plomb, ainsi, pour une protection suffisante contre les rayonnements ambiants, les appareils sont relativement legers et l'une des realisations a pu etre installee dans un laboratoire mobile. Les conditions d'utilisation (mouvement propre, etalonnage) et les resultats obtenus sont donnes; tous les radioelements emetteurs gamma sont mesurables en 15 minutes a un niveau inferieur a la dose de tolerance. On presente enfin des applications a la spectrographie gamma d'echantillons volumineux (poudres ou liquides) et de tres faible activite: elles interessent des domaines tres varies comme, par exemple, la geophysique (etude des retombees radioactives) ou l'industrie chimique

  9. Determination of the cross-sections of some nuclear reactions occurring as a result of cosmic radiation (1963); Determination des sections efficaces de quelques reactions nucleaires intervenant dans les effets ou rayonnement cosmique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Tamers, M A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The high energy reactions studied during this research are reactions liable to occur as a result of cosmic radiation. On the one hand the reaction {sup 16}O(p, 3p){sup 14}C was studied and its cross-section measured between 65 MeV and 2.7 GeV; a value of 2.3 mb {+-} 0.5 was found. These values have mode it possible to forecast measurable quantities of carbon-14 in meteorites and also to measure them. On the other hand the reactions {sup 12}C({sup 16}O...), {sup 12}C({sup 14}N...) and {sup 12}C({sup 12}C...) have been studied and an attempt has been made to explain the mechanism of these reactions. (author) [French] Les reactions a hautes energies qui ont ete etudiees au court de ce travail sont des reactions susceptibles de se produire sous l'effet du rayonnement cosmique. Il s'agit d'une part de la reaction {sup 16}O(p, 3p){sup 14}C dont on a mesure la section efficoce egale a 2,3 mb {+-} 0,5 entre 65 MeV et 2,7 GeV. Ces valeurs ont permis de prevoir des quantites mesurables de carbone 14 dans les meteorites et par suite de les determiner. D'autre part les reaction {sup 12}C({sup 16}O...), {sup 12}C({sup 14}N...) et {sup 12}C({sup 12}C...) ont ete etudiees et on a tente d'expliquer le mecanisme de ces reactions. (auteur)

  10. Parálisis cerebral :

    OpenAIRE

    Cabrero Izquierdo, María del Carmen

    2012-01-01

    Se aborda el tema de la parálisis cerebral definiendo qué es, clasificando los tipos de parálisis dependiendo de la afectación y las características principales. Se explican algunos de sus tratamientos, se dan sistemas alternativos y/o aumentativos de comunicación para un alumno con PC (parálisis cerebral).

  11. Some methods for the detection of fissionable matter; Quelques methodes de detection des corps fissiles

    Energy Technology Data Exchange (ETDEWEB)

    Guery, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-03-01

    A number of equipments or processes allowing to detect uranium or plutonium in industrial plants, and in particular to measure solution concentrations, are studied here. Each method has its own field of applications and has its own performances, which we have tried to define by calculations and by experiments. The following topics have been treated: {gamma} absorptiometer with an Am source, detection test by neutron multiplication, apparatus for the measurement of the {alpha} activity of a solution, fissionable matter detection by {gamma} emission, fissionable matter detection by neutron emission. (author) [French] On examine ici plusieurs appareils ou procedes qui permettent de detecter l'uranium ou le plutonium dans les installations industrielles, et en particulier de mesurer les concentrations de solutions. Chacune des methodes a son domaine d'application et ses performances, qu'on a tente de definir par le calcul et par des experiences. Les sujets traites sont les suivants: absorptiometre {gamma} a source d'americium, essais de detection par multiplication neutronique, appareil de mesure de l'activite {alpha} d'une solution, detection des matieres fissiles par leur emission {gamma}, detection des matieres fissiles par leur emission neutronique. (auteur)

  12. Measurement of Placental Blood Flow with {sup 133}Xe in Normal and Pathological Human Pregnancy; Mesure du Debit Placentaire dans les Grossesses Normales et Pathologiques

    Energy Technology Data Exchange (ETDEWEB)

    Pontonnier, G.; Delmas, H.; Farre, J.; Favretto, R. [Clinique Obstetricale, Hopital de la Grave, Toulouse (France)

    1971-02-15

    practical standpoint, it provides one more element for the surveillance of pregnancies involving high foetal risk and makes it possible to study the action of drugs administered to the mother on placental blood flow. (author) [French] La plupart des auteurs s'accordent a reconnaitre l'importance des alterations de la circulation placentaire dans la genese de la souffrance foetale chronique. Or il n'existait pas jusqu'ici de technique qui permette une evaluation quantitative de l'hemodynamique placentaire. Les auteurs presentent une methode de mesure du debit placentaire qui est une application des radioisotopes a la mesure des debits locaux. Ils utilisent le xenon-133 en solution dans du serum physiologique; ce gaz radioactif presente l'avantage d'etre inerte et instantanement diffusible. Apres localisation radiographique ou ultrasonique du placenta, ils injectent par voie trans-abdominale 50 {mu}Ci de xenon dans le placenta. L'enregistrement de la courbe de clearance du xenon-133 est effectue au moyen d'un detecteur a scintillation. La courbe obtenue est en meme temps enregistree sur un inscripteur lineaire et transmise a un calculateur automatique. Les auteurs ont ainsi realise 111 mesures de debit placentaire: 45 dans des grossesses normales, 59 dans des grossesses pathologiques et 7 apres perfusion medicamenteuse. Les mesures effectuees ont permis pour la premiere fois de chiffrer la valeur du debit placentaire chez la femme. Pour les grossesses normales, entre la 32{sup e} et la 41{sup e} semaine, il est de 145 ml/100 g/min. Les mesures effectuees au cours de grossesses pathologiques (hypertension arterielle, dysgravidie, infection urinaire, diabete, grossesse prolongee) ont montre que celles-ci s'accompagnent d'une diminution du debit placentaire statistiquement significative. L'importance de cette diminution est en rapport avec la clinique et l'etat de l'enfant a la naissance. Cette methode de mesure, facilement reproductible chez la meme femme, presente donc un

  13. Measurement of the purity of graphite and heavy water; Controle de purete du graphite et de l'eau lourde

    Energy Technology Data Exchange (ETDEWEB)

    Hering, H

    1959-02-01

    The analytical methods used by the C.E.A. are described, I -- Graphite. The determination of the change in the neutron capture cross section from sample to sample is determined by, an oscillation method in the Zoe reactor, or by measuring the attenuation of a neutron flux in the subcritical system Mireille. Methods of analysing total ash, B, H, Cl, Na, Ca. Fe, Mo, Ti, V, Sm, Eu, Dy, S, Co and Cd are described and mean results are given. The methods for sampling are indicated. II -- Heavy crater. The isotopic analysis of heavy water is carried out by infra-red absorption measurements. Chemical purity is evaluated by electrical conductivity measurements, B, Na, Mg, K, Cr, Mn, Ni, Cu, Cd, are determined by spectrographic methods, and Cl{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup --}, NH{sub 4}{sup +} by chemical methods; finally, sensitive pH measurements are described. [French] On decrit les methodes d'examen en usage au Commissariat a l'Energie Atomique. I -- Graphite. L'evaluation de la capture neutronique se fait par oscillation dans la pile Zoe, ou par mesure de l'attenuation d'un flux neutronique dans l'empilement sous critique Mireille. On indique les methodes de dosages et des resultats de: cendres, B, H, Cl, Na, Ca, Fe, Mo, Ti, V, Sm, Eu, Dy, et de S, Co, Cd, ainsi que les modalites d'echantillonnage. II.- Eau lourde. Le dosage isotopique dans les eaux lourdes se fait par absorptiometrie infrarouge. Leur purete chimique est evaluee par mesure de leur conductibilite electrique; les dosages d'impuretes se font par spectrographie d'emission (B, Na, Mg, K, Mn, Ni, Cu, Cd) et par des methodes chimiques (Cl{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup --}, NH{sub 4}{sup +}). On decrit la delicate mesure de pH. (auteur)

  14. L'ÉGALITÉPOUR LES FEMMES ET LES FILLES L'ACTION DU CRDI

    International Development Research Centre (IDRC) Digital Library (Canada)

    Cathy Egan

    de trouver un emploi décent, de créer une entreprise ou de se lancer en ... Stratégie générale ... En 2006, des travaux financés par le CRDI sur le recrutement ... politiques, ne sont bien souvent pas visées par les mesures de réparations.

  15. Propriétés d'un fil quantique connecté à des fils de mesure

    Science.gov (United States)

    Safi, Inès.

    étique. Afin d'identifier les flux d'électrons incident et transmis, des fils intermédiaires sans interactions sont introduits, et le système global est traité comme un liquide de Tomonaga-Luttinger inhomogène. La transmission du flux est parfaite dans la limite stationnaire : un électron incident est transmis en une série de charges partielles spatialement séparées dont la somme vaut l'unité. Il est par ailleurs remarquable que les parties charge et spin transmises restent séparées dans le fil externe sans interactions. La conductance est déduite de la transmission parfaite suivant un argument analogue à celui de l'approche de diffusion. Elle peut aussi être reliée exactement à la transmission en modélisant les réservoirs par un potentiel électrostatique externe fixé. Elle est donc égale à e2/h pour une portée finie arbitraire des interactions. Ce résultat de conductance a été confirmé par des observations expérimentales récentes sur les fils quantiques (Tarucha et al. et Yacoby et al.) dont la conductance présente un plateau à e2/h dans la limite balistique (haute température). Ceci contredit le consensus général jusque-là admis, prédisant en particulier une réduction de la conductance par des interactions répulsives qui devient encore plus importante pour des interactions à longue portée. Le transport dynamique est développé en présence des contacts. La conservation globale de la charge est assurée en tenant compte d'une grille avoisinante. Les coefficients de conductance dynamiques sont exprimés en fonction de la transmission et de la réflexion des plasmons, qui dépendent eux-mêmes des interactions. Il est possible d'étendre cette approche à des fils de mesure avec interactions, quoique des hypothèses supplémentaires sont nécessaires. Par ailleurs, dans le cas usuel d'interactions invariantes par translation, ce travail en donne une revue relativement complète, en suivant des méthodes différentes et en d

  16. Etude du déplacement de l'huile par le gaz Analysis of Oil Displacement by Gas

    Directory of Open Access Journals (Sweden)

    Delclaud J.

    2006-11-01

    Full Text Available Les ingénieurs « réservoir u prévoient avec beaucoup de difficultés l'exploitation des gisements en utilisant les relations perméabilités relatives-saturations fournies par les laboratoires. Ceci amène à se demander si le concept est valide en écoulement transitoire, si les mesures sont effectuées selon des procédures convenables, si la relation statique entre la pression capillaire et la saturation est conservée en régime variable, si enfin la méconnaissance des lois de combinaison de ces fonctions n'est pas la cause de l'insatisfaction des ingénieurs. Le travail présenté ici traite des trois premiers points. Deux séries d'expériences sont réalisées à cet effet : - d'une part, des expériences de déplacement de l'huile par le gaz, où l'on s'intéresse à l'établissement et à la caractérisation de phénomènes pseudo-stationnaires. Les échantillons poreux choisis sont de faibles dimensions. Ils permettent ainsi de réduire la durée des périodes transitoires; - d'autre part, des expériences de déplacement sur des échantillons homogènes de grandes dimensions où l'on étudie les phénomènes transitoires. On mesure, tout au long du massif, la pression dans les deux phases et la saturation. Les perméabilités relatives sont calculées en tout point et à tout instant, à partir des équations de continuité. II ressort de ces travaux que la relation perméabilité relative-saturation est la même en tout point du milieu poreux, tout au long de l'écoulement transitoire, qu'elle ne dépend pas de la vitesse d'écoulement et que la relation pression capillaire-saturation coïncide avec celle établie par la méthode des états restaurés. La validité du concept en écoulement transitoire est donc prouvée. La méthode de WELGE, JOHNSON, BOSSLER et NAUMANN conduit à des résultats différents de ceux obtenus. On montre, pour expliquer ces écarts, que les hypothèses théoriques de cette méthode sont

  17. Fast neutron dosimetry in research reactors; Dosimetrie en neutrons rapides dans les reacteurs de recherche

    Energy Technology Data Exchange (ETDEWEB)

    Eckert, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This work chiefly concerns the measurement of fast neutron fluxes by means of threshold detectors. It is shown first that the cross sections to use for measurements by threshold detectors depend largely on the neutron spectrum, that is the position in which the measurement is performed. The spectrum is determined by calculation for several positions in the piles EL2 and EL3; from this can be deduced the cross-sections to be used for the measurements carried out in these positions. In the last part of the report, possible methods for the experimental determination of the spectrum are indicated. (author) [French] On etudie principalement la mesure des flux de neutrons rapides a l'aide de detecteurs a seuil. On montre d'abord que les sections efficaces a utiliser pour les mesures par detecteurs a seuil, dependent grandement du spectre des neutrons, c'est-a-dire de l'emplacement ou s'effectue la mesure. La determination du spectre est effectuee par le calcul pour plusieurs emplacements des piles EL2 et EL3; on en deduit les sections efficaces a utiliser pour les mesures effectuees a ces emplacements. Dans la derniere partie du rapport, on indique quelles methodes sont possibles pour la determination experimentale du spectre. (auteur)

  18. Thermal diffusivity of solids; Diffusivite thermique des solides

    Energy Technology Data Exchange (ETDEWEB)

    Kleimann, H; Fetiveau, Y; Richard, M; Eyraud, L; Eyraud, C; Elston, J [Institut National des Sciences Appliquees, Lyon (France); Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The authors recall the different methods of thermal diffusivity measurements and point out the possible causes of errors. They study in particular the sinusoidal methods of thermal attack using the measurement of either an amplitude or a phase, in which the controlled energy in-put is obtained either by Joule effect or by radiation. By the use of controlled systems, it is possible to apply those methods to the measurement of thermal diffusivity of their samples in a large scale of temperature. The authors describe their experimental achievements and give several results dealing especially with Al{sub 2}O{sub 3}, BeO, MgO. (author) [French] Les auteurs rappellent les diverses methodes de mesure de la diffusivite thermique et indiquent les sources d'erreurs possibles. Ils etudient particulierement les methodes d'attaque thermique sinusoidales utilisant soit une mesure d'amplitude, soit une mesure de phase dans lesquelles l'apport energetique controle est effectue soit par effet Joule, soit par rayonnement. La mise en oeuvre de systemes asservis permet l'utilisation de ces methodes pour la mesure de la diffusivite thermique d'echantillons minces dans une gamme etendue de temperature. Les auteurs decrivent les realisations experimentales et fournissent divers resultats concernant notamment Al{sub 2}O{sub 3}, BeO, MgO. (auteur)

  19. Study of the low energy gamma transitions of molybdenum 99; Etude des transitions gamma de basse energie du molybdene 99

    Energy Technology Data Exchange (ETDEWEB)

    Ravier, J.

    1959-07-01

    The study of the decay scheme of Mo{sup 99} has been performed on the magnetic iron-less and double focalization spectrograph of the Institute of Nuclear Physics of Lyon. Methods of internal and external conversion have been used. The intensities of the Mo{sup 99} sources used were not strong enough to determine the characteristics of the internal conversion accurately but were sufficient to precise the decay scheme at low energy. We have determined the internal conversion ratio for the transition of 180 KeV, we have got: 0.13 ± 0.03 which is not in agreement with the value given by a previous experiment based on γ-γ coincidence. Our method seems to be more reliable. We confirm the E2 feature of this transition and its 5/2+ spin. We have determined another important parameter for the 180 KeV de-excitation: the percentage of transitions that do not pass by the isomeric level but by the 140 KeV level is (6 ± 2)%, the isomeric level being at 142 KeV. The gamma spectra at low energy has been studied through the photoelectric effect in a lead converter [French] L'etude du schema de desintegration du Mo{sup 99} deja faite par differents auteurs a ete reprise par des methodes de conversion interne et externe, an moyen du spectrographe magnetique sans fer et a double focalisation de l'Institut de Physique Nucleaire de Lyon. Apres avoir cherche les possibilites d'obtention de sources de haute activite specifique par separation isotopique Szilard-Chalmers sur des molybdates alcalins, le spectre de conversion interne a basse energie a ete mesure. Ainsi se trouverent etre determines les coefficients partiaux de conversion interne. Le spectre γ a basse energie a ete etudier au moyen de l'effet photoelectrique sur un convertisseur de plomb. Les coefficients de conversion interne et les intensites relatives des differentes transitions ont ete calcules moyennant certaines hypotheses. La comparaison entre les valeurs donnees par la theorie et l'experience des differentes

  20. Contribution have the survey of the transformation {sup 181}Hf {yields} {sup 181}Ta (17 {mu}s) {yields} {sup 181}Ta; Contribution a l'etude de la transformation {sup 181}Hf {yields} {sup 181}Ta (17 {mu}s) {yields} {sup 181}Ta

    Energy Technology Data Exchange (ETDEWEB)

    Baullini, R; Chaminade, R; Desneiges, P; Grjebine, T; Quidort, J; Wahl, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-07-01

    The metastable state of Ta, whose period is around 20 microseconds, has been discovered by De BENEDETTI and Mc GOWAM who done measurements of deferred coincidences between the particles beta and the electrons of conversion given out by the hafnium radiated by thermal neutrons. We measured the period of {sup 181}Ta{sup *} by measures of deferred coincidences {beta}-e{sup -} and {beta}-{gamma}. A method of survey of the specter of photons amplitudes emitted by {sup 181}Ta{sup *} has been fit. This method permitted to solve the presence of {gamma} in the radiation emitted in synchronism with the deexcitation of {sup 181}Ta{sup *}. Finally in a last chapter, we propose a method of dosage of the {sup 181}Hf in presence of other radioelements. (M.B.) [French] L'etat metastable de Ta, dont la periode est voisine de 20 microsecondes, a ete decouvert par DE BENEDETTI et Mc GOWAM qui effectuaient des mesures de coincidences differees entre les particules beta et les electrons de conversion emis par du hafnium irradie par des neutrons thermiques. Nous avons mesure la periode de {sup 181}Ta{sup *} par des mesures de coincidences differees {beta}-e{sup -} et {beta}-{gamma}. Une methode d'etude du spectre d'amplitudes des photons emis par {sup 181}Ta{sup *} a ete mise au point. Cette methode a permis d'eclaircir la presence de {gamma} dans le rayonnement emis en synchronisme avec la desexcitation de {sup 181}Ta{sup *}. Enfin dans un dernier chapitre, on proposera une methode de dosage du {sup 181}Hf en presence d'autres radioelements. (M.B.)

  1. Study of the effect of the energy spectrum and of the total flux on the damage produced by neutrons in solids; Contribution a l'etude de l'influence du spectre et du flux integre sur les dommages crees par les neutrons dans les solides

    Energy Technology Data Exchange (ETDEWEB)

    Dulieu, P C [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-01-01

    In the first part are studied the general relationships between the physical effects produced by neutrons in solids, and the total flux and neutron energy spectrum; some examples are given. The second part, describes the application to a silicon damage detector whose principle is to use the damage produced in a PIN Junction for measuring the neutron flux (intermediate and fast) received by the detector. Chapter I is devoted to the experimental determination of the energy given to the atoms by a primary in the silicon. The results and conclusions drawn from this determination make it possible to consider, in chapter II, the calculation of the detectors response characteristics.Chapter III deals with the measurement of the detectors response function and it is noted that good agreement is obtained between the calculation and experimental results. The whole of the second part constitutes a test of the methods presented in the first part. (author) [French] Dans la premiere partie, nous etudions les relations generales qui lient les effets physiques engendres par les neutrons dans les solides au flux integre et au spectre des neutrons et nous donnons des exemples d'utilisation. La deuxieme partie est une application au detecteur de dommages en silicium, dont le principe est d'utiliser les dommages crees dans une jonction PIN pour mesurer les flux de neutrons (intermediaires et rapides) recus par le detecteur. Le chapitre I est consacre a la determination experimentale de l'energie cedee aux atomes par un primaire dans le silicium. Les resultats et les conclusions que l'on peut tirer de cette determination permettent d'aborder, au chapitre II, le calcul de la fonction de reponse du detecteur. Le chapitre III porte sur la mesure de la fonction de reponse du detecteur et on constate qu'il y a un bon accord entre le calcul et l'experience. L'ensemble de la deuxieme partie constitue un test des methodes exposees dans la premiere partie. (auteur)

  2. Novel role for proteinase-activated receptor 2 (PAR2) in membrane trafficking of proteinase-activated receptor 4 (PAR4).

    Science.gov (United States)

    Cunningham, Margaret R; McIntosh, Kathryn A; Pediani, John D; Robben, Joris; Cooke, Alexandra E; Nilsson, Mary; Gould, Gwyn W; Mundell, Stuart; Milligan, Graeme; Plevin, Robin

    2012-05-11

    Proteinase-activated receptors 4 (PAR(4)) is a class A G protein-coupled receptor (GPCR) recognized through the ability of serine proteases such as thrombin and trypsin to mediate receptor activation. Due to the irreversible nature of activation, a fresh supply of receptor is required to be mobilized to the cell surface for responsiveness to agonist to be sustained. Unlike other PAR subtypes, the mechanisms regulating receptor trafficking of PAR(4) remain unknown. Here, we report novel features of the intracellular trafficking of PAR(4) to the plasma membrane. PAR(4) was poorly expressed at the plasma membrane and largely retained in the endoplasmic reticulum (ER) in a complex with the COPI protein subunit β-COP1. Analysis of the PAR(4) protein sequence identified an arginine-based (RXR) ER retention sequence located within intracellular loop-2 (R(183)AR → A(183)AA), mutation of which allowed efficient membrane delivery of PAR(4). Interestingly, co-expression with PAR(2) facilitated plasma membrane delivery of PAR(4), an effect produced through disruption of β-COP1 binding and facilitation of interaction with the chaperone protein 14-3-3ζ. Intermolecular FRET studies confirmed heterodimerization between PAR(2) and PAR(4). PAR(2) also enhanced glycosylation of PAR(4) and activation of PAR(4) signaling. Our results identify a novel regulatory role for PAR(2) in the anterograde traffic of PAR(4). PAR(2) was shown to both facilitate and abrogate protein interactions with PAR(4), impacting upon receptor localization and cell signal transduction. This work is likely to impact markedly upon the understanding of the receptor pharmacology of PAR(4) in normal physiology and disease.

  3. Special Topics in Optical Propagation.

    Science.gov (United States)

    1981-07-01

    station terrestre , le faisoeau tree intenee eerai~t autonntiquement point,& eur La etation ter- reetre par le signal de eondage grtris par ceLle-ci et...d’eepacer de 100 kmn, ou davantage, lee rdp9- teure eur lee cab Lee pour lee commtun-.oation8 eoue-marinee ou terrestree . Noter que Lee fibree et lee cab...nos mesures at qu’il y a aussi une bonne concordance Trlatruectr- vde par lea capteurs de vitesse at Ia turbulence de tempfirature mesurle par Una

  4. Evaluation de la rigidité artérielle par la vitesse de progression de l’onde pouls doigt-orteil mesuré par pOpmetre® chez des sujets noirs africains atteints de sclérodermie systémique [Evaluation of arterial stiffness by finger-toe pulse wave velocity measured by pOpmetre® in black africans patients with systemic scleroderma

    Directory of Open Access Journals (Sweden)

    Moussa Diallo

    2017-11-01

    Full Text Available Background: The purpose of this study was to assess the arterial stiffness (AS in black africans patients with systemic scleroderma. Patients and Methodology: A prospective cross-sectional hospital survey has been performed over a 6-month period, including 55 black african individuals, aged over 16 years and consenting, consisting of 29 patients with systemic scleroderma and 26 hospitalized controls. The finger-toe pulse wave velocity (ft-PWV was recorded by popmetre® and comparaison between the 2 groups has been performed with statistical analysis. Results: The mean ft-PWV was 9,56 m/s ± 3,09 in the patient group and 7,71 m/s ± 2,63 in control group. The ft-PWV was significantly higher in patients with scleroderma compared to controls (p<0.0145. The study of the relationship between AS and independent variables in multivariate analysis demonstrated that having scleroderma increase by 1.81 times the value of the ft-PWV after adjustment for age and systolic blood pressure. Discussion: To our knowledge, this is the first assessment of the AS in black african patients with scleroderma. It shows that ft-PWV was significantly higher in patients with scleroderma compared to controls. Also, this high AS was imputable to the scleroderma. Conclusion: In Africa, the measurement of the AS by popmetre® could be a simple, rapid, non invasive and pratical early detection and follow-up of cardio-vascular involvments in the course of scleroderma. RÉSUMÉ Introduction: L’objectif de notre étude était d’évaluer la résistance artérielle (RA chez les patients noirs africains atteints de SS. Patients et Méthode: Une enquête hospitalière prospective transversale a été réalisée sur une période de 6 mois, portant sur 55 sujets noirs africains, âgés de plus de 18 ans, consentants, composé de 29 malades atteints de SS et 26 témoins hospitalisés. La vitesse de progression de l’onde pouls doigt-orteil (VOPdo a été mesuré par Popmètre dans

  5. Methode d’Identification des Forces Aerodynamiques Instationnaires sur les Essais en Vol, Validation Experimentale (Method of Mathematical Identification of Unsteady Airloads From Flight Measurements, Experimental Validation)

    Science.gov (United States)

    2000-05-01

    gage en vol de rdponses de jauges de contraintes en responses in maneuver, illustrated by an example manoeuvre, illustrd par un exemple issu de la coming...sous ddrapage, ... , braquages gouvernes,..) la forme: -Les mesures sont directement les rkponses de - minimiser Z = Q(k - Xj tb) 2 jauges de...3, la rdponse - les facteurs de ponddration des mesures, fli ou incidence de l’avion, la rdponse de la jauge plus ou momns subjectifs, sont remplacds

  6. Monitoring d'une installation éolienne : Application à la ...

    African Journals Online (AJOL)

    Des shunts sont utilisés pour mesurer le courant délivré par l'éolienne. Tous les capteurs sont reliés à la centrale d'acquisition CR800 de type Campbell Scientific qui assure la collecte et l'archivage des données. L'exploitation des mesures obtenues montrent deux régimes de vents distincts associés à la saison sèche et à ...

  7. Mesures en matière de taxation des produits du tabac en Afrique de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Mesures en matière de taxation des produits du tabac en Afrique de l'Ouest. En décembre 2007, le programme Recherche pour la lutte mondiale contre le tabac (RMCT) a entrepris une initiative afin de comprendre les facteurs cruciaux qui peuvent déterminer le succès de la lutte antitabac en Afrique subsaharienne.

  8. Nuclear study of Melusine; Etude nucleaire de Melusine

    Energy Technology Data Exchange (ETDEWEB)

    Cherot, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In this report are reviewed - with respect to starting of experiments - the main nuclear characteristics of a 20 per cent enriched uranium lattice, with light water as moderator and reflector. The reactor is to operate at 1 MW. 1) Study of various critical masses. 2) Control. Effectiveness of cadmium. Control rods and of a stainless steel regulating rod. 3) Study of the effect on reactivity of disturbances in the core center. 4) Study of xenon and samarium poisoning. 5) Temperature factor. 6) Heat exchanges in a fuel element. (author) [French] On etudie, dans ce rapport, les principales proprietes nucleaires d'un reseau a uranium enrichi (20 pour cent), dont le moderateur et le reflecteur sont l'eau legere en vue des experiences de demarrage. Ce reacteur devra fonctionner a 1 MW. 1) Etude de diverses masses critiques. 2) Controle. Efficacite des barres de controle en cadmium et d'une barre de reglage en acier inoxydable. 3) Etude de l'effet sur la reactivite de perturbation au centre du coeur. 4) Etude de l'empoisonnement xenon et samarium. 5) Coefficient de temperature. 6) Echanges thermiques dans un element. (auteur)

  9. Mécanismes d'écoulement des charges à la surface des polymères granulaires

    Directory of Open Access Journals (Sweden)

    M. Kachi

    2014-09-01

    Full Text Available Les forces électriques s’exerçant sur des polymères granulaires chargés sont mises à profit dans plusieurs processus électrostatiques. La dynamique de charges de surface de ces matériaux est très importante pour ce type de processus. Le but de ce papier est d’analyser l’écoulement des charges à la surface de couches compactes de polymères granulaires, en interprétant les mesures sans contact réalisées par trois sondes de potentiel, de champ et de charge, ayant chacune une taille différente. Des mesures du profile de potentiel à différents instants sont également réalisées afin d’expliquer les différences entre les vitesses de déclin de potentiel, de champ et de charge mesurées par les trois sondes. Les résultats mettent en évidence un écoulement transversal et longitudinal de la charge surfacique.

  10. Study of the effect of the energy spectrum and of the total flux on the damage produced by neutrons in solids; Contribution a l'etude de l'influence du spectre et du flux integre sur les dommages crees par les neutrons dans les solides

    Energy Technology Data Exchange (ETDEWEB)

    Dulieu, P.C. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-01-01

    In the first part are studied the general relationships between the physical effects produced by neutrons in solids, and the total flux and neutron energy spectrum; some examples are given. The second part, describes the application to a silicon damage detector whose principle is to use the damage produced in a PIN Junction for measuring the neutron flux (intermediate and fast) received by the detector. Chapter I is devoted to the experimental determination of the energy given to the atoms by a primary in the silicon. The results and conclusions drawn from this determination make it possible to consider, in chapter II, the calculation of the detectors response characteristics.Chapter III deals with the measurement of the detectors response function and it is noted that good agreement is obtained between the calculation and experimental results. The whole of the second part constitutes a test of the methods presented in the first part. (author) [French] Dans la premiere partie, nous etudions les relations generales qui lient les effets physiques engendres par les neutrons dans les solides au flux integre et au spectre des neutrons et nous donnons des exemples d'utilisation. La deuxieme partie est une application au detecteur de dommages en silicium, dont le principe est d'utiliser les dommages crees dans une jonction PIN pour mesurer les flux de neutrons (intermediaires et rapides) recus par le detecteur. Le chapitre I est consacre a la determination experimentale de l'energie cedee aux atomes par un primaire dans le silicium. Les resultats et les conclusions que l'on peut tirer de cette determination permettent d'aborder, au chapitre II, le calcul de la fonction de reponse du detecteur. Le chapitre III porte sur la mesure de la fonction de reponse du detecteur et on constate qu'il y a un bon accord entre le calcul et l'experience. L'ensemble de la deuxieme partie constitue un test des methodes exposees dans la premiere partie

  11. Mesure de la vitesse d'infiltration des eaux dans le sol : Cas des sols ...

    African Journals Online (AJOL)

    C'est donc une infiltration superficielle qui ne peut pas modifier la composition des eaux de l'aquifère. Ces sols sont alors favorables à une telle agriculture. Mots clés: mesure, vitesse, infiltration, sols, pollutions, eau, Niari, Congo. English Title: Measuring the speed of the water infiltration into the soil: case of the soil of the ...

  12. Vers une (r)évolution du renseignement belge : la nécessaire émergence d'une communauté du renseignement

    OpenAIRE

    Leroy, Patrick

    2017-01-01

    Le renseignement belge entre dans une période de (r)évolution amenée par la crise des attentats qui secouent le sol européen. La tentations est grande pour les décideurs politiques de palier les "failles" du renseignement par des mesures radicales qui pourraient atteindre l'ADN, le coeur de métier du renseignement.

  13. Integration of the nuclear energy among the production facilities of energy in France; Integration de l'energie nucleaire parmi les moyens de production de l'energie en france

    Energy Technology Data Exchange (ETDEWEB)

    Ailleret, P [Electricite de France (EDF), 75 - Paris (France). Direction des Etudes et Recherches; Taranger, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The present report gives an overview of the present facilities of energy productions in France and their perspectives. the electric production comes for half about power stations hydraulics and for half of thermal power stations. However due to the increase of the energy consumption, France is particularly interested by the atomic energy that appears to bring a supply in due time to the hydraulics and to limit a development of the thermal power stations to which the natural resources of France in classic fuel would not permit to cope presumably. The integration of the nuclear plants to the other production facilities will make itself gradually according to the evolution of the energy needs. (M.B.) [French] Le present rapport donne un apercu des moyens actuels de productions energetiques en France et de ses perspectives. la production electrique provient pour moitie environ de centrales hydraulique et pour moitie de centrales thermiques. Cependant face a l'augmentation de la consommation energetique, la France est tres particulierement interessee par l'energie atomique qui parait devoir apporter en temps utile la releve a l'hydraulique et limiter un developpement des centrales thermiques auxquels les ressources naturelles de la France en combustible classique ne permettraient vraisemblablement pas de faire face. L'integration des centrales nucleaires aux autres moyens de production se fera graduellment en fonction de l'evolution des besoins energetiques. (M.B.)

  14. Par Pond vegetation status 1996

    International Nuclear Information System (INIS)

    Mackey, H.E. Jr.; Riley, R.S.

    1996-12-01

    The water level of Par Pond was lowered approximately 20 feet in mid-1991 in order to protect downstream residents from possible dam failure suggested by subsidence on the downstream slope of the dam and to repair the dam. This lowering exposed both emergent and nonemergent macrophyte beds to drying conditions resulting in extensive losses. A survey of the newly emergent, shoreline aquatic plant communities of Par Pond began in June 1995, three months after the refilling of Par Pond to approximately 200 feet above mean sea level. These surveys continued in July, September, and late October, 1995, and into the early spring and late summer of 1996. Communities similar to the pre-drawdown, Par Pond aquatic plant communities continue to become re-established. Emergent beds of maidencane, lotus, waterlily, watershield, and Pontederia are extensive and well developed. Measures of percent cover, width of beds, and estimates of area of coverage with satellite data indicate regrowth within two years of from 40 to 60% of levels prior to the draw down. Cattail occurrence continued to increase during the summer of 1996, especially in the former warm arm of Par Pond, but large beds common to Par Pond prior to the draw down still have not formed. Lotus has invaded and occupies many of the areas formerly dominated by cattail beds. To track the continued development of macrophytes in Par Pond, future surveys through the summer and early fall of 1997, along with the evaluation of satellite data to map the extent of the macrophyte beds of Par Pond, are planned

  15. Re-enrichment of depleted uranium by passage through a gaseous diffusion installation; Reenrichissement de l'uranium appauvri par passage dans une installation de diffusion gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, P; Billous, O [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The reader will find in this paper an economic study of the re-utilization of depleted uranium from nuclear reactors, whether its content be above or under natural proportions. Re-utilization is possible either through bringing the depleted product up to its initial content of {sup 235}U by mixture with a richer concentrate, or else by passing it through a gaseous diffusion plant. The economic area of such re-utilization depends on a number of considerations. We give a general study of it, with reference to some typical gaseous diffusion facilities. (author)Fren. [French] Ce rapport examine au point de vue economique la reutilisation de l'uranium appauvri provenant des reacteurs nucleaires, qu'il soit indifferemment en dessus ou en dessous de la teneur naturelle. Cette reutilisation peut se faire soit en ramenant le produit a sa teneur initiale en isotope 235 par un melange convenable avec un concentre plus riche, soit en le faisant passer dans une usine de Diffusion Gazeuse. La zone de rentabilite de cette reutilisation depend de diverses conditions economiques. Elle est etudiee ci-dessous d'une maniere generale, puis en se referant a des installations-type de diffusion gazeuse. (auteur)

  16. Limits to the Recognizability of Flaws in Non-Destructive Testing Steam-Generator Tubes for Nuclear-Power Plants; Limitations de l'Efficacite de la Detection des Defauts par Essais Non Destructifs de Tubes de Bouilleurs pour Centrales Nucleaires; Predely ehffektivnosti nedestruktivnoj defektoskopii trub parogeneratorov yadernykh ehlektrostantsij; Limites para Distinguir los Defectos en el Ensayo No Destructivo de Tubo para Generadores de Vapor Destinados a Centrales Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlmann, A.; Adamsky, F. -J. [Technischer Ueberwachungs-Verein Reinland e.V., Cologne (Germany)

    1965-10-15

    -Verein' de Rhenanie qui a ete charge de surveiller et de controler la fabrication et le montage des bouilleurs, pour garantir que cet element de la centrale soit aussi exempt que possible de defauts. L'experience acquise dans l'execution de ces travaux peut etre tres utile pour la fabrication et le montage des bouilleurs de n'importe quel type de centrale nucleaire. Le memoire traite des limitations de l'efficacite des essais non destructifs de tubes de bouilleurs. Les auteurs discutent plus particulierement les essais ci-apres: a) Controle automatique par ultrasons de tubes droits dans l'usine de production; b) Controle combine, par ultrasons et par radiographie, de tubes coudes et de soudures; c) Autres controles non destructifs. (author) [Spanish] En la Republica Federal de Alemania se estan construyendo reactores nucleares con generadores de vapor situados en el interior del tanque de presion. Las caracteristicas de este modelo dificultan considerablemente la reparacion de los tubos del generador que puede llegar a paralizar la central nuclear por largos periodos. Como es bien sabido, muchas de las dificultades para mantener en funcionamiento las centrales nucleares de tipo clasico provienen de averias en los tubos del generador de vapor. Por ello, y teniendo tambien en cuenta como razon no menos importante el elevado costo total de esos reactores, es preciso construir los generadores de vapor de tal manera que el factor carga de la central sea lo mas elevado posible. El Technischer Ueberwachungs-Verein Rheinland se encarga de dirigir e inspeccionar la fabricacion y la construccion de generadores de vapor para que esa parte de las instalaciones carezca en lo posible de defectos. La experiencia adquirida a ese respecto ofrece ademas interes para la fabricacion y construccion de los generadores de vapor que se destinan a las centrales nucleares en general. En la presente memoria se examinan los limites de rendimiento del ensayo no destructivo de los tubos para generadores

  17. Special equipment for processing can-rupture measurements; Equipement specialise de traitement des mesures de rupture de gaines

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, J.; Phalippou, J.; Dumont, D.; Viellard, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    installees sur des reacteurs nucleaires utilisent dans la partie du traitement des mesures en totalite ou en partie un calculateur numerique. La fiabilite du systeme est limitee par celle du calculateur, celui-ci representant un point commun pour tout le traitement DRG. Pour satisfaire aux exigences de la securite de fonctionnement il faudrait envisager dans certains cas de doubler le calculateur. L'utilisation d'un calculateur necessite comme interface entre l'equipement de detection et lui-meme des echelles fonctionnant en integrateur pour les impulsions sortant du detecteur. En ajoutant un certain nombre de circuits a ces echelles on est capable d'effectuer le travail demande actuellement au calculateur, en ce qui concerne le calcul. Ce raisonnement nous a conduit a une solution dite ''decentralisee'' en realisant des equipements specialises au niveau du prospecteur meme. Nous croyons que cette solution represente, en dehors de l'aspect de fiabilite, surtout un interet economique. Dans notre solution, le point commun dans le traitement d'information se situe maintenant non plus au niveau d'elaboration du resultat comme dans le cas du calculateur, mais a un niveau plus bas, dans l'impression des resultats. Meme dans le cas d'une defaillance du point commun, les resultats sont elabores, affiches et compares aux seuils d'alarme. Dans le cas d'une panne d'un equipement specialise les resultats de ce prospecteur ne sont plus disponibles, les autres restent en fonction. Il semble que cette solution represente un degre de fiabilite meilleur que la solution utilisant les calculateurs universels. L'utilisation d'une technique a tiroir interchangeable (MULTIBLOC) permet un remplacement rapide de l'equipement specialise en panne. L'emploi systematique des circuits integres (TTL) assure une fiabilite accrue de l'equipement. (auteur)

  18. Protection of uranium by electrodeposition of nickel and diffusion; Protection de l'uranium par nickelage electrolytique et diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Chauvin, G; Coriou, H; Hure, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    diffusion, that which is richest in nickel UNi{sub 5}, is the hardest and most brittle. This brittleness results in the systematic appearance of fractures at the Ni-UNi{sub 5} interface; all the diffusion layers remain fixed to the uranium. (author) [French] Ce travail s'integre dans le cadre tres general du probleme de gainage de l'uranium dans les reacteurs nucleaires. En effet il convient notamment: - D'assurer une protection du combustible (uranium) contre la corrosion par le refrigerant (eau lourde, CO, etc.) dans le cas d'une rupture de gaine (Al, Zr, etc.); - D'eviter la diffusion prohibitive U-Al (cas d'une gaine en aluminium) par l'emploi d'une couche intermediaire d'un metal dont la cinetique de diffusion avec l'uranium soit, dans les memes conditions, considerablement plus faible que celle de l'aluminium. De la presente etude, basee sur l'utilisation eventuelle du nickel comme couche intermediaire, on peut degager les principaux points suivants: 1) Apres lui avoir fait subir un traitement de surface chimique determine, on peut realiser sur l'uranium des depots electrolytiques de nickel d'une adherence telle que, apres un recuit sans l'application d'aucune pression, ces depots donnent lieu a une bonne diffusion intermetallique U-Ni. Tout en restant tres inferieure a celle du systeme U-Al, cette diffusion permet de renforcer la protection, donc d'accroitre la resistance du combustible a la corrosion. 2) Toutes autres conditions egales par ailleurs, l'experience montre que la qualite des zones de diffusion obtenues depend de la nature du bain de nickelage. 3) Les bains classiques de nickelage utilises jusqu'a present dans ce domaine d'etude contiennent 20 a 40 g/l d'acide borique a titre de tampon electrolytique. Il en resulte une contamination extremement elevee des depots de nickel par 400 a 500 ppm de bore. Nous montrons qu'avec au moins un bain exempt de poisons nucleaires, on peut obtenir des zones de diffusion U-Ni tres saines. 4) Apres un recuit de 100 heures

  19. Some dynamic aspects of the thyroid function studied by a method of isotopic balance; Quelques aspects dynamiques de la fonction thyroidienne etudies par une methode d''equilibre isotopique'

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Claude

    1958-06-15

    This report addresses the use of a method which aims at directly measuring quantities of steady iodine involved by the thyroid metabolism in specific physiological conditions. The experiment is based on the use of male rats weighting 180 to 200 g which received an almost iodine-free diet. The daily dose of iodine is administered to each experimental group through beverage under the form of potassium iodide. After a delay, the usual beverage is replaced by a marked one. Iodine renewal by thyroid is monitored in vivo by external detection of radiations emitted by iodine 131. At the end of the experiment, rats are killed, and their blood is collected on heparin, centrifuged and processed to separate mineral iodine and hormonal iodine. Radioactivity is then measured with a scintillator and compared with that of a beverage sample [French] Le but de la methode utilisee est de mesurer directement les quantites d'iode stable mises en jeu par le metabolisme thyroidien dans des conditions physiologiques precises. Les travaux anterieurs ne permettent d'atteindre ces quantites que par des microdosages chimiques longs et delicats. En nous basant sur le principe du renouvellement d'un pool en etat dynamique stationnaire, nous decrivons une cinetique et mesurons en valeur absolue les differents parametres de ce systeme en equilibre.

  20. Experimental contamination of margaritana margaritifera (L) (a Fresh water bivalve) by caesium 137; Contamination experimentale de margaritana margaritifera (L) (bivalve d'eau douce) par le cesium 137

    Energy Technology Data Exchange (ETDEWEB)

    Foulquier, L; Bovard, P; Grauby, A [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1966-07-01

    The hydro biological research carried out in the Radio-Ecology Section has led the authors to study some Margaritana sampling stations situated down-stream from the Monts d'Arree nuclear power station. They describe the preservation and contamination methods used for fixing the {sup 137}Cs concentration factors in the case of Margaritana Margaritifera (L). The results of experiments carried out over a period of one hundred days show that the specific activity of the various organs is stabilized after thirty to thirty-five days. The authors have noticed a relatively low adsorption on the shell through the intermediary of micro-organisms, and a strong and rapid absorption in the soft parts. The concentration factors have values, at equilibrium, of around: 9 for the shell, 300 for all the organs, and 38 for the whole animal. A comparison of these results with work published by other authors makes it possible to draw general conclusions concerning the mechanism of {sup 137}Cs fixation by lamellibranch, as well as their capacity of fixation. (author) [French] Les etudes hydrobiologiques effectuees au sein de la Section de Radio-Ecologie ont amene les auteurs a etudier des stations de prelevement de Margaritana en aval de la Centrale Nucleaire des Monts d'Arree. Ils decrivent les methodes de conservation et de contamination utilisees pour l'etablissement des facteurs de concentration du {sup 137}Cs par Margaritana margaritifera (L). Les resultats des experimentations menees pendant cent jours montrent que les activites specifiques de la coquille et des differents organes se stabilisent au bout de trente a trente-cinq jours. Les auteurs constatent une adsorption relativement faible sur la coquille par l'intermediaire des micro-organismes et une absorption forte et rapide dans les parties molles. Les facteurs de concentration se situent, a l'equilibre, autour de: 9 pour la coquille, 300 pour l'ensemble des organes et 38 si l'on considere l'animal total. Cette etude

  1. Thermal diffusivity measurements between 0 {sup 0}C and 2000 {sup 0}C: application to UO{sub 2}; Mesure de la diffusivite thermique de 0 {sup 0}C et 2000 {sup 0}C application a UO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Van Craeynest, J C; Weilbacher, J C; Lallement, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    We have built two types of apparatus to measure the thermal diffusivity of ceramic fuels. The first apparatus, based on Angstrom's method, operates between 0 deg. C and 1000 deg. C. Satisfactory results have been obtained for iron, nickel and molybdenum. The other apparatus, based on Cowan's method, operates between 1000 deg. C and 2000 deg. C on thin slabs. The thermal conductivity of UO{sub 2} has been measured from 0 deg. C to 2000 deg. C. There is a good agreement between our results and the well known values for UO{sub 2}. (authors) [French] Afin d'etudier la conductibilite thermique des combustibles ceramiques, nous avons mis au point deux types d'appareils nous permettant de mesurer la diffusivite thermique {alpha}, la conductibilite etant egale au produit de la diffusivite par la densite et la chaleur specifique. Un premier type d'appareil base sur la methode d'Angstroem nous permet d'obtenir des resultats de diffusivite sur echantillon de fabrication courante entre 0 deg.C et 1000 deg. C. Une serie de mesures a ete effectuee sur le fer, le nickel et le molybdene afin de controler le bon fonctionnement des appareils. Un deuxieme type d'appareil base sur la methode de Cowan nous permet d'atteindre la diffusivite thermique d'echantillons minces entre 1000 deg. C et 2000 deg. C. Un controle des resultats obtenus sur l'oxyde d'uranium a moyenne et haute temperature nous permet de conclure a un tres bon accord entre nos resultats et ceux de la litterature. (auteurs)

  2. Les clients des services d'escorte tels que perçus par des femmes offrant ces services

    Directory of Open Access Journals (Sweden)

    Jacqueline

    2015-07-01

    Full Text Available La discussion de projets de loi criminalisant l'achat des services sexuels constitue un sujet brûlant d'actualité dans plusieurs pays, dont le Canada. Pourtant, bon nombre d'études indiquent que la plupart des clients agissent de manière civilisée envers la personne travailleuse du sexe, alors que seule une infime minorité de clients présentent des comportements violents. Interviewant 16 femmes offrant des services d'escorte, quant à leur expérience de sexualité dans le cadre du travail, celles-ci ont beaucoup discuté des besoins qu'elles percevaient chez leurs clients, de même que des attitudes de ces derniers envers elles. Les participantes décrivent ceux-ci comme étant le plus souvent respectueux, la plupart recherchant un contact chaleureux avec elle et agissant en conséquence. En outre, ceux des clients qui ne recherchent qu'une expérience sexuelle tendent à être également respectueux envers l'escorte. Par contre, certains clients présentent une attitude ou un comportement désagréable. Quelques participantes ont également eu affaire à un client violent au cours de leur parcours comme escorte. La plupart des participantes étaient en mesure de choisir leurs clients, ce qui leur a permis de surtout rencontrer des clients aimables et qui, à l'occasion, leur procure également du plaisir sexuel. Par contre, les participantes plus vulnérables et moins capables de choisir et de maintenir leurs limites ont rencontré plus de clients désagréables ou agressifs.

  3. 1 Mise au point d'une méthodologie d'étalonnage d'une presse ...

    African Journals Online (AJOL)

    PR BOKO

    3. la limite de liquidité L. L ;. 4. la limite de retrait R. L . Mais dans le cadre de cet article, la plasticité d'un sol sera décrite par les variables p. L et p. I . En définitive, tous les produits fabriqués à partir du matériau terre peuvent être caractérisés par les paramètres d'assemblage et leurs performances mesurées par les valeurs ...

  4. Preparation and study of the properties of lead telluride and cadmium telluride diodes for use in nuclear spectrometry; Preparation et etude des proprietes de diodes au tellurure de plomb et au tellurure de cadmium en vue d'une utilisation en spectrometrie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Lancon, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    resistivite de notre materiau nous empeche de l'utiliser en detection de rayonnements nucleaires. Differents types de structures a base de CdTe ont ete etudiees. L'une des diodes realisees a permis la detection de particules alpha. Les performances limitees de ce detecteur sont expliquees par la presence dans CdTe de defauts de reseau jouant le role de centres de recombinaison des porteurs de charge. L'analyse des proprietes de diodes realisees par diffusion d'or dans CdTe a permis d'identifier ce defaut, la lacune de cadmium, dont la presence est due a un ecart a la stoechiometrie lors de la preparation du materiau. (auteur)

  5. Contribution to the study of collective states of heavy nuclei by means of coulomb excitation; Contribution a l'etude des etats collectifs des noyaux lourds par excitation coulombienne

    Energy Technology Data Exchange (ETDEWEB)

    Barloutaud, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-06-15

    The following nuclei were excited by protons of 5 MeV maximum energy: {sup 182}W - {sup 184}W - {sup 186}W - {sup 186}Os - {sup 188}Os - {sup 189}Os - {sup 190}Os - {sup 192}Os - {sup 194}Pt - {sup 196}Pt - {sup 198}Pt - {sup 198}Hg - {sup 200}Hg - {sup 202}Hg - {sup 204}Hg - {sup 206}Pb. The reduced probabilities of the various transitions were deduced from the coulomb excitation cross-section measurements. For some even-even nuclei two 2 + levels were excited. The properties of the excited levels are interpreted in terms of the collective model. (author) [French] Au moyen de protons d'energie inferieure a 5 MeV, l'excitation coulombienne des noyaux suivants a ete etudiee: {sup 182}W - {sup 184}W - {sup 186}W - {sup 186}Os - {sup 188}Os - {sup 189}Os - {sup 190}Os - {sup 192}Os - {sup 194}Pt - {sup 196}Pt - {sup 198}Pt - {sup 198}Hg - {sup 200}Hg - {sup 202}Hg - {sup 204}Hg - {sup 206}Pb. La mesure de la section efficace d'excitation coulombienne a permis de deduire les -probabilites reduites des diverses transitions observees. Dans certains noyaux pair-pair, deux niveaux de caractere 2 + ont ete excites. L'interpretation de ces niveaux en termes de niveaux de rotation et de niveaux de vibration a l'aide du modele collectif est discutee. En particulier, la variation des proprietes de ces niveaux avec la deformation nucleaire permet de fixer des limites a la validite des diverses hypotheses entrant dans le modele collectif. (auteur)

  6. Measurement units of physical values; Unites de mesure des grandeurs physiques

    Energy Technology Data Exchange (ETDEWEB)

    Debraine, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1955-07-01

    The aim of this paper is twofold: 1) to give an analysis of the formation conditions of the various systems of units, 2) to show how the practical problems involving changes of units can be solved. This analysis leads to the conception of 'types' of systems, which is very useful to clarity the question of rationalized and non rationalized systems. The second point which consists essentially in: 1) finding the relationship between the measures of a given quantity in different systems, 2) deriving practical formulas, 3) deriving formulas in various 'types' of systems, is made easier by use of sets of: * definition formulas, * transformation formulas, * units of the various practical systems with useful numerical information covering the following fields: ** geometry, ** kinematics, ** mechanics, ** electricity and magnetism, ** thermodynamics, ** radiation, ** photometry, These sets being printed on coloured paper can be easily found. A number of numerical examples (21) show in a detailed way how to solve the various problems likely to occur. A chapter is particularly devoted to the Giorgi MKS system. (author) [French] Le but de cet expose est double: 1) donner une analyse des conditions de formation des differents systemes d'unites, 2) montrer comment peuvent se resoudre les problemes pratiques de changement d'unites. Cette analyse amene a 1a conception de ''types'' de systemes, conception tres utile pour eclairer la question des systemes rationalises et non rationalises. La seconde partie du programme qui consiste essentiellement: 1) a determiner les relations entre les mesures d'une meme grandeur dans differents systemes, 2) a etablir des formules pratiques, 3) a etablir les formules valables dans un ''type'' de systeme donne est facilitee par l'utilisation de listes classees de 1) formules de definition, 2) equations de transformation, 3) unites des differents systemes accompagnees de relations numeriques utiles, couvrant les domaines suivants: 1) geometrie, 5

  7. Experimental contamination of margaritana margaritifera (L) (a Fresh water bivalve) by caesium 137; Contamination experimentale de margaritana margaritifera (L) (bivalve d'eau douce) par le cesium 137

    Energy Technology Data Exchange (ETDEWEB)

    Foulquier, L.; Bovard, P.; Grauby, A. [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1966-07-01

    The hydro biological research carried out in the Radio-Ecology Section has led the authors to study some Margaritana sampling stations situated down-stream from the Monts d'Arree nuclear power station. They describe the preservation and contamination methods used for fixing the {sup 137}Cs concentration factors in the case of Margaritana Margaritifera (L). The results of experiments carried out over a period of one hundred days show that the specific activity of the various organs is stabilized after thirty to thirty-five days. The authors have noticed a relatively low adsorption on the shell through the intermediary of micro-organisms, and a strong and rapid absorption in the soft parts. The concentration factors have values, at equilibrium, of around: 9 for the shell, 300 for all the organs, and 38 for the whole animal. A comparison of these results with work published by other authors makes it possible to draw general conclusions concerning the mechanism of {sup 137}Cs fixation by lamellibranch, as well as their capacity of fixation. (author) [French] Les etudes hydrobiologiques effectuees au sein de la Section de Radio-Ecologie ont amene les auteurs a etudier des stations de prelevement de Margaritana en aval de la Centrale Nucleaire des Monts d'Arree. Ils decrivent les methodes de conservation et de contamination utilisees pour l'etablissement des facteurs de concentration du {sup 137}Cs par Margaritana margaritifera (L). Les resultats des experimentations menees pendant cent jours montrent que les activites specifiques de la coquille et des differents organes se stabilisent au bout de trente a trente-cinq jours. Les auteurs constatent une adsorption relativement faible sur la coquille par l'intermediaire des micro-organismes et une absorption forte et rapide dans les parties molles. Les facteurs de concentration se situent, a l'equilibre, autour de: 9 pour la coquille, 300 pour l'ensemble des organes et 38 si l'on considere

  8. Mesurer le droit de participer à la vie culturelle: le développement des indicateurs

    NARCIS (Netherlands)

    Donders, Y.; Bouchard, J.; Gandolfi, S.; Meyer-Bisch, P.

    2013-01-01

    Dans les domaines des droits de l'homme, de la culture et du développement, des cadres et mécanismes sont développés afin de mesurer et de qualifier les relations entre ces domaines et leur impact sur la vie des individus en des communautés. Les indicateurs constituent un élément important de ces

  9. Project for an analogue divider using electronic counting; Projet de diviseur analogique par comptage electronique

    Energy Technology Data Exchange (ETDEWEB)

    Novat, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The apparatus which has been developed is designed to give the reciprocal of a number between 10{sup 3} and 10{sup 7}. In practice this number can be the pulse count provided during a given time by a detector of the BF{sub 3} type during a criticality experiment. The apparatus is made up of two parts: one provides, by means of relays, a voltage proportional to the reciprocal required, the other is a numeric voltmeter measuring this voltage between 0.1 and 1 volt. The relative error of the result is under 5 per cent. (author) [French] L'appareillage etudie et realise, est destine a fournir l'inverse d'un nombre compris entre 10{sup 3} et 10{sup 7}. En pratique ce nombre est le taux d'impulsions delivrees pendant un temps donne, par un detecteur du type BF{sub 3}, au cours d'une manipulation de criticalite. L'appareillage est compose de deux parties: l'une fournit a l'aide de relais une tension proportionnelle a l'inverse cherche, l'autre est un voltmetre numerique mesurant cette tension comprise entre 0,1 et 1 Volt, L'erreur relative sur le resultat est inferieure a 5%. (auteur)

  10. Methods for determining thermal stresses values. Some examples relating to nuclear reactors; Methodes de determination des contraintes thermiques. Quelques exemples d'application aux reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J; Gautier, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Peres, A [Israel Institute of Technology, Dept. of Nuclear Science Technion (Israel)

    1958-07-01

    As modern techniques develop more elaborate machines, and make their way towards higher and higher temperatures and pressures, the thermal stresses become a matter of major importance in the design of mechanical structures. In the first part of this paper, the authors examine the problem from a theoretical standpoint, and try to evaluate the aptitude and limitation of mathematical techniques to attain the quantitative values of thermal stresses. This paper deals mainly with the experimental methods to measure thermal stresses. The authors show some examples relating to nuclear reactors. (author)Fren. [French] Au fur et a mesure que la technique moderne developpe des machines plus poussees et s'oriente vers des temperatures et des pressions toujours plus elevees, les contraintes thermiques deviennent un facteur d'importance capitale dans le calcul des structures mecaniques. Les auteurs examinent d'abord l'aspect theorique du probleme, ainsi que l'aptitude et les limites du calcul pour exprimer quantitativement la valeur des contraintes thermiques. Les auteurs exposent principalement, ensuite, les methodes experimentales qui permettent de mesurer ces contraintes, et illustrent cet expose de quelques exemples relatifs aux installations nucleaires. (auteur)

  11. Alternatives to imprisonment: opportunities and problems in Germany / Mesures alternatives à l’incarcération : opportunités et problèmes en Allemagne

    Directory of Open Access Journals (Sweden)

    Bahr Alexander

    2016-12-01

    Full Text Available L'articolo fornisce una breve panoramica sulla normativa tedesco in materia di misure alternative alla detenzione. Vengono successivamente presentati i dati statistici relativi agli istituti penitenziari tedeschi e gli autori riflettono sulle problematiche principali della situazione attuale delle carceri tedesche. Inoltre, sulla base di dati statistici e di esempi pratici, l'articolo presenta una panoramica complessiva sulle misure alternative in Germania e sullo stato dell’arte della ricerca. Infine, gli autori sottolineano il ruolo e la prospettiva delle vittime, arrivando alla conclusione che una serie di iniziative e di progetti sono già stati avviati, ma che è ancora troppo presto per poter giungere a delle conclusioni. Cet article donne un aperçu du cadre juridique allemand des mesures alternatives à l’incarcération. Des données statistiques sur les prison allemandes et sur les détenus sont ensuite présentées. Les auteurs s’interrogent sur certains des principaux problèmes liés à la situation actuelle des prisons allemandes. De plus, cet article donne un aperçu global des mesures alternatives en Allemagne par le biais de données statistiques et d’exemples concrets. S’ensuit l’état des évaluations scientifiques et de la recherche. Enfin, les auteurs valorisent le rôle et la perspective des victimes, toutefois dans leurs conclusions ils soulignent que nombreux sont les programmes et les initiatives déjà commencés, mais qu’il est cependant encore trop tôt pour dresser un bilan. The article provides a short overview on the German legal framework regarding alternatives to imprisonment. Then statistical data about German prisons and their inmates are presented and the authors reflect on some major problems of the contemporary situation in German prisons. Furthermore, the article gives a comprehensive overview on alternative measures in Germany by statistical data and examples from the practice. Then the state

  12. Detection of burst cans in the reactors cooled by gaseous phase; Detection des ruptures de gaine dans les reacteurs refroidis par phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Labeyrie, J; Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    In a nuclear reactor including the bars or plates cooled by a gaseous fluid, burst risks to occur in the sheath assuring the tightness separation between the cooling gas and the fissile materials. It is necessary to be able to detect the formation of these cracks as possible in order to avoid all risk of fission products release or any reaction of uranium to the contact of the refrigerating gas. It is however the increase of the radioactivity in the cooling gas due to the scattering of the fission products that permits to signal the apparition of a crack or to follow its evolution. It is possible to detect cracks of the order of the square millimeter. In this report, we will detail the principle and the realization of a device used for the surveillance of a natural uranium reactor cooled by air circulation. (M.B.) [French] Dans un reacteur nucleaire comportant des barres ou des plaques refroidies par un fluide gazeux des fissures risquent de se produire dans les gaines assurant la separation etanche entre le gaz de refroidissement et les materiaux fissiles. II est necessaire de pouvoir detecter la formation de ces fissures des que possible afin d'eviter tout risque de liberation de produits de fission ou de reaction de l'uranium au contact du gaz refrigerant. C'est cependant l'augmentation de la radioactivite du gaz de refroidissement due a la dispersion des produits de fission qui permet de signaler l'apparition d'une fissure ou de suivre son evolution. On peut ainsi detecter des fissures de l'ordre du millimetre carre. Dans ce rapport, nous detaillerons le principe et la realisation d'un appareil utilise pour la surveillance d'un reacteur a uranium naturel refroidi par circulation d'air. (M.B.)

  13. Symetrie en energie des spectres de l'onde de densite de charge dans le 2-hydrogene seleniure de niobium

    Science.gov (United States)

    Behmand, Behnaz

    Les mecanismes qui menent a la supraconductivite dans les supraconducteurs a haute temperature critique sont encore aujourd'hui mal compris contrairement a ceux dans les supraconducteurs conventionnels. Dans les hauts-Tc, certaines modulations de la densite d'etats electroniques coexistant avec la phase supraconductrice ont ete observees, ce qui engendre des questionnements sur leur role dans la supraconductivite. En fait, plusieurs types de modulation de la densite d'etats electroniques existent, comme par exemple l'onde de densite de charge et l'onde de densite de paires. Ces deux modulations, d'origines differentes et mesurables avec la technique de spectroscopie par effet tunnel, peuvent etre differenciees avec une etude de leur symetrie. Ce memoire consistera donc a presenter l'etude de la symetrie de l'onde de densite de charge dans le 2H-NbSe2 qui est presente dans la phase supraconductrice a 300 mK. Par contre, certaines difficultes liees au principe de mesure, soit l'effet de normalisation, nuisent a l'identification de cette symetrie. La methode, pour contourner ce probleme sera alors l'element clef de ce travail.

  14. Bonheur et progrès : mesurer le bien-être au Bhoutan et au Canada ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    31 janv. 2011 ... Étant l'un des pays les moins développés, le Bhoutan s'inquiète de la mondialisation et il est déterminé à protéger sa spécificité culturelle. Il veut préserver ses valeurs sociales en les ancrant dans des termes que le monde entier pourra comprendre et respecter, c'est-à-dire en les quantifiant. En mesurant ...

  15. Technical and Economic Problems Associated with the Development of Methods of Processing and Using Radioactive Waste; Problemes techniques et economiques lies au developpement des methodes de traitement et d'utilisation des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Thiriet, L; Sauteron, J; Oger, C [Commissariat a l' Energie Atomique, Fontenay-Aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The paper briefly reviews the various techniques used in processing the radioactive wastes which unavoidably result from the generation of electric power from nuclear sources. The paper goes on to define the relative importance, in nuclear fuel cycles, of the problem raised by these wastes. Emphasis is placed on the economic influence of management policies on the cost of power generation, and hence on the relative position of nuclear energy. A substantial percentage of these wastes can be economically utilized. Attention is drawn to the major technical and economic features of the industry which will come into being as a result of this utilization. The major uses anticipated are discussed: radiation sources, heat sources, auxiliary power generation. The paper concludes that satisfactory solutions have already been found to these problems, and describes possible improvements. (author) [French] La communication rappelle d'abord succinctement les differentes techniques de traitement des dechets radioactifs resultant necessairement de la production d'electricite d'origine nucleaire. On situe ensuite l'importance du probleme pose par ces residus dans le cycle du combustible nucleaire. On fait ressortir l'influence economique du choix des methodes de gestion sur le cout de production de l'energie, et par consequent sur la place devolue a l'energie nucleaire. Une part importante de ces dechets peut faire l'objet d'une utilisation rentable de l'industrie qui naitra de cette utilisation. Les principales applications envisagees sont evoquees: sources d'irradiation, sources chauffantes, generateurs auxiliaires d'energie. On conclut que d'ores et deja des solutions satisfaisantes ont ete apportees a ces problemes, et l'on decrit les perspectives d'amelioration concevables. (auteur)

  16. Protease-activated receptor (PAR)-2 is required for PAR-1 signalling in pulmonary fibrosis

    NARCIS (Netherlands)

    Lin, Cong; von der Thüsen, Jan; Daalhuisen, Joost; ten Brink, Marieke; Crestani, Bruno; van der Poll, Tom; Borensztajn, Keren; Spek, C. Arnold

    2015-01-01

    Idiopathic pulmonary fibrosis is the most devastating diffuse fibrosing lung disease of unknown aetiology. Compelling evidence suggests that both protease-activated receptor (PAR)-1 and PAR-2 participate in the development of pulmonary fibrosis. Previous studies have shown that bleomycin-induced

  17. Contrôle de la température durant le processus de dégradation d'un acier Z12CNS20 en frottement avec un acier Z200C13

    Science.gov (United States)

    Khanafi-Benghalem, N.; Loucif, K.; Benghalem, K.; Boudoukha, H.; Louahdi, R.

    2005-05-01

    La température de contact lors des essais d'usure varie d'une manière spontanée et aléatoire. Cette température de contact dépend essentiellement de la nature du couple des matériaux en contact de la charge et de la vitesse. Cependant la mesure de la température est très difficile à effectuer compte tenu du choix de l'endroit de prise de la température et des phénomènes d'évacuation de la chaleur et de la dissipation de l'énergie. Dans ce travail nous exposons une méthode très simple de mesure de la température et nous étudions par conséquent la variation de la température du Z12CNS20 / Z200C13. Au cours des essais d'usure pour différentes vitesses de glissement, nous montrons en effet que la température augmente d'une manière progressive en fonction de la vitesse puis elle s'élève brutalement au fur et à mesure qu'on se rapproche du point de contact, et enfin nous prouvons par observation métallographique que l'échantillon subit un écoulement plastique provoqué par l'élévation de la température en fonction de la vitesse.

  18. Etude de la magnetoresistance du compose supraconducteur YB a2 ...

    African Journals Online (AJOL)

    00 ;0,01 ; 0,03 ; 0,06 ; 0,10 ; 0,20 ; 0,25) ont été élaborés par la méthode de réaction à l'état solide. L'effet de différents cycles de recuit sur la substitution du cuivre par le titane dans l'YBCO a été faite à travers des mesures de résistivité ...

  19. Comité Scientifique de la Revue des Sciences et de la Technologie ...

    African Journals Online (AJOL)

    MICROSIM

    For each bee, 19 morphological characters were measured. Appropriate .... Tableau 1. Sites et ruchers, coordonnées géographiques, nombre d'abeilles ouvrières mesurées par rucher ..... classification. In: Bee Genetics and Breeding T.E..

  20. 2500-IJBCS-Article-Dr Neya Bouma James

    African Journals Online (AJOL)

    hp

    DANIDA) et l'Organisation Africaine de la Propriété Intellectuelle (OAPI) pour leurs soutiens financiers. RESUME. Un champ ensemencé avec des ...... interne et externe par l'adoption de mesures comme l'utilisation de semences saines, le.

  1. Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Chandanson, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This article concerns a induction flow indicator used at the reactor of Chatillon for the measure of the water debits. It has two sensitivities respectively 2,5 m{sup 3}/h and 10 m{sup 3}/h to the maxima of deviation. The precision of the measures is 1 percent of the maximum of the scale. The equipment is constituted an electronic amplifier followed by a synchronous demodulator functioning to the frequency of the sector. (author) [French] L'article concerne un debitmetre a induction utilise a la Pile de Chatillon pour la mesure des debits d'eau. Il y a deux sensibilites respectivement 2,5 m{sup 3}/h et 10 m{sup 3}/h aux maxima de deviation. La precision des mesures est de 1 pour cent du maximum de l'echelle. L'appareillage est constitue d'un amplificateur electronique suivi d'un demodulateur synchrone fonctionnant a la frequence du secteur. (auteur)

  2. Complexation studies of actinides (U, Pu, Am) with linear polyamino-carboxylate ligands and sidero-chelates; Etudes de la chelation d'actinides (U, Pu, Am) par des ligands polyaminocarboxylate lineaires et des siderochelates d'interet environnemental

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, L.V.

    2010-11-25

    'aide de mesures par spectroscopie EXAFS (Extended X-ray Absorption Fine Structure) effectuees au synchrotron de l'ESRF. Ces travaux ont ete completes par des etudes thermodynamiques realisees en couplant des mesures potentiometriques et spectrophotometriques UV-Visible afin d'identifier la nature des complexes d'uranium(VI) et d'americium(III) formes en solution et d'evaluer leur stabilite. A l'aide des constantes d'equilibre, il est possible de simuler le diagramme de speciation dans les conditions de traitement des effluents du centre de Valduc et de definir ainsi une gamme de pH dans laquelle le ligand est efficace pour atteindre une decontamination 'ultime'

  3. High-Temperature Gas-Cooled Reactor Critical Experiment and its Application to Thorium Absorption Rates; Experience Critique pour l'Etude d'un Reacteur a Haute Temperature, Refroidi par un Gaz et son Application a la Determination des Taux d'Absorption du Thorium; Kriticheskij opyt, postavlennyj na vysokotemperaturnom reaktore s gazovym okhlazhdeniem, i primenenie ego dlya opredeleniya stepeni pogloshcheniya toriya; Experimento Critico Efectuado en un Reactor de Elevada Temperatura Refrigerado por Gas y su Aplicacion para Calcular los Indices de Absorcion del Torio

    Energy Technology Data Exchange (ETDEWEB)

    Bardes, R. G.; Brown, J. R.; Drake, M. K.; Fischer, P. U.; Pound, D. C.; Sampson, J. B.; Stewart, H. B. [General Dynamics Corporation,San Diego, CA (United States)

    1964-04-15

    the fact that the thorium is dispersed in graphite and the usual cadmium-ratio technique is difficult to apply. Comparison of experimental and theoretical results shows excellent agreement over a range of variables. In addition, the results of both activation and reactivity measurements of Doppler coefficient are in agreement, a fact which is felt to be significant in view of the disparity between results from these two techniques in the literature. (author) [French] Lors de l'etude du reacteur HTGR a haute temperature refroidi par un gaz, et de son premier prototype a Peach Bottom, la General Atomic Division de la societe General Dynamics a decide qu'il fallait proceder a une experience critique pour obtenir certaines donnees d'entree necessaires pour l'analyse nucleaire. Aux fins de l'etude nucleaire theorique, les besoins particuliers en donnees d'entree relatives aux absorptions par le thorium ont amene les ingenieurs a concevoir un assemblage experimental critique compose d'un reseau central entoure d*une region tampon et d'une region de commande. Ce type.d'assemblage, dans lequel on peut creer le spectre a mesurer dans le reseau central relativement petit ayant la geometrie voulue, permet d'obtenir des donnees d'entree tres diverses pour les etudes de projets nouveaux, au point de vue de l'analyse nucleaire. Le memoire indique les avantages particuliers que presente cette methode par rapport a celle qiu consiste a construire une maquette, ainsi que le role de la theorie pour determiner quelles experiences sont le plus utiles et comment utiliser ensuite ces experiences dans la verification des procedes d'etude. Les auteurs ont mis au point deux methodes relativement nouvelles qui peuvent etre utilisees avec l'assemblage decrit ci-dessus: une methode d'oscillation de la reactivite pour determiner le coefficient Doppler pour le thorium; une methode d'activation pour determiner a la fois l'integrale de resonance pour le thorium disperse dans le graphite et ses

  4. Synthesis and purification of some alkyl phenanthrenes and presentation of their infrared, ultraviolet, nuclear magnetic resonance and mass spectra; Synthese et purification de quelques alcoylphenanthrenes et presentation ds leurs spectres d'absorption infrarouge, ultraviolette, de resonance magnetique nucleaire et de masse

    Energy Technology Data Exchange (ETDEWEB)

    Persaud, K. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-01-01

    We have carried out the synthesis of: - phenanthrene - its five monomethyl derivatives - three dimethyl derivatives - two trimethyl derivatives. We have then purified these products as well as a certain number of others obtained from various sources. We have been able to obtain in the majority of cases, a purity of 99.5 per cent or over, these figures being obtained by low voltage mass spectrometry. Finally we have recorded the infrared, ultraviolet, nuclear magnetic resonance and mass spectra of these products for which an atlas has been drawn up. (author) [French] Nous avons realise la synthese: - du phenanthrene - de ses cinq derives monomethyles - de trois de ses derives dimethyles - de deux de ses derives trimethyles. Nous avons ensuite purifie ces produits ainsi qu'un certain nombre d'autres que nous avons obtenus de sources differentes. Nous avons pu atteindre, dans la plupart des cas, une purete egale ou superieure a 99,5 pour cent, chiffres determines par la spectrometrie de masse a basse tension. Enfin, nous avons enregistre les spectres infrarouges, ultraviolets, de resonance magnetique nucleaire et de masse de ces produits dont nous avons fait un atlas. (auteur)

  5. Thermodynamic study of sulphur hemi-oxide using mass spectrometry (1963); Etude thermodynamique de l'hemioxyde de soufre par spectrometry de masse (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Hagemann, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-01-15

    have also examined the work concerning the heat of formation of SO to discover whether the formation of SO is possible between 1000 deg K and 1500 deg K starting from sulphur and SO{sub 2}. (author) [French] L'action de l'oxygene sur le soufre, a basse pression, dons une decharge haute frequence, a ete etudiee en analysant en continu, les produits de la reaction par spectrometrie de masse. Les spectres de masse du gaz issu de la decharge correspondent a un melange SO{sub 2}, S{sub 2}O, S{sub 2} et O{sub 2}. Nous avons mesure jusqu'a 75 pour rent de SO{sub 2} dans le melange SO{sub 2} + S{sub 2}O. Nous avons conclu a l'absence des molecules S{sub 2}O{sub 2}, et SO dans le melange. Les potentiels d'ionisation des molecules, et d'apparition des ions fragments du melange issu de la decharge, ont ete etudies par spectrometrie de masse. La chaleur de formation de S{sub 2}O a ete estimee a partir des mesures des potentiels d'apparition des ions SO{sup +} provenant de SO{sub 2}, et S{sub 2}O. (- 18.5 kcal/mole - < {delta}H, (S{sub 2}O{sub g}) < - 7 kcal/mole). Nous avons ete amenes a mesurer les potentiels d'ionisation des molecules S{sub 2}, S{sub 4}, S{sub 6} et S{sub 8} dont les valeurs sont respectivement: 9,7 {+-} 0,1 eV; 10,4 {+-} 0,5 eV; 8,5 {+-} 0,3 eV et 7,3 {+-} 0,3 eV. Nous avons enfin etudie l'equilibre de formation de StO a partir de soufre et de S{sub 2}O, dans un reacteur a filaments chauds. La mesure de la variation, entre 1100 deg K et 1500 deg K. de h constante d'equilibre de la reaction: SO{sub 2} + 3/2 S{sub 2} {r_reversible} 2 S{sub 2}O a permis de determiner la variation d'enthalpie de cette reaction ({delta}H = 5310 {+-} 370 calories) La somme d'etats de la molecule S{sub 2}O, Z{sup 0}, a ete calculee a partir des donnees bibliographiques. En appliquant a l'equilibre de formation de S{sub 2}O l'equation: Log K{sub p} = {delta}Log Z{sup 0}/N - {delta}H{sup 0}{sub 0}/RT nous avons calcule l'enthalpie de ia reaction au zero absolu ({delta}H{sup 0}{sub 0

  6. Contribution to the study of defects created by {alpha} particles in uranium at 4.2 K; Contribution a l'etude des defauts crees par irradiation a l'aide de particules {alpha} dans l'uranium a 4.2 K

    Energy Technology Data Exchange (ETDEWEB)

    Raharinaivo, A L [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    A device is described for the irradiation, in liquid helium, of metallic strips with {alpha} particles produced by radioactive sources. It has thereby been possible to measure changes in resistivity of variously treated uranium samples (cold- worked, annealed, previously exposed to neutrons, etc. ) as a function of the irradiation flux. The annealings carried out after irradiation compare favorably to those effected after a quenching from 100 to 4 K (JOUSSET experiments). The results are discussed; it is concluded that a defect, very probably of the interstitial type, is mobile in uranium at temperatures below 5 K. (author) [French] On decrit un dispositif permettant d'irradier, dans l'helium liquide, des lames metalliques par des particules {alpha} issues de sources radioactives. On a ainsi mesure les variations de resistivite, en fonction du flux d'irradiation, d'uranium diversement traite (ecroui, recuit, prealablement irradie par des neutrons...). Les recuits apres irradiation se comparent bien aux recuits apres trempe de 100 a 4 K (experiences de JOUSSET). L'ensemble des resultats est discute et il conduit a la conclusion qu'un defaut, tres vraisemblablement interstitiel, est mobile dans l'uranium a des temperatures inferieures a 5 K. (auteur)

  7. Developpement d'une methode de Monte Carlo dependante du temps et application au reacteur de type CANDU-6

    Science.gov (United States)

    Mahjoub, Mehdi

    La resolution de l'equation de Boltzmann demeure une etape importante dans la prediction du comportement d'un reacteur nucleaire. Malheureusement, la resolution de cette equation presente toujours un defi pour une geometrie complexe (reacteur) tout comme pour une geometrie simple (cellule). Ainsi, pour predire le comportement d'un reacteur nucleaire,un schema de calcul a deux etapes est necessaire. La premiere etape consiste a obtenir les parametres nucleaires d'une cellule du reacteur apres une etape d'homogeneisation et condensation. La deuxieme etape consiste en un calcul de diffusion pour tout le reacteur en utilisant les resultats de la premiere etape tout en simplifiant la geometrie du reacteur a un ensemble de cellules homogenes le tout entoure de reflecteur. Lors des transitoires (accident), ces deux etapes sont insuffisantes pour pouvoir predire le comportement du reacteur. Comme la resolution de l'equation de Boltzmann dans sa forme dependante du temps presente toujours un defi de taille pour tous types de geometries,un autre schema de calcul est necessaire. Afin de contourner cette difficulte, l'hypothese adiabatique est utilisee. Elle se concretise en un schema de calcul a quatre etapes. La premiere et deuxieme etapes demeurent les memes pour des conditions nominales du reacteur. La troisieme etape se resume a obtenir les nouvelles proprietes nucleaires de la cellule a la suite de la perturbation pour les utiliser, au niveau de la quatrieme etape, dans un nouveau calcul de reacteur et obtenir l'effet de la perturbation sur le reacteur. Ce projet vise a verifier cette hypothese. Ainsi, un nouveau schema de calcul a ete defini. La premiere etape de ce projet a ete de creer un nouveau logiciel capable de resoudre l'equation de Boltzmann dependante du temps par la methode stochastique Monte Carlo dans le but d'obtenir des sections efficaces qui evoluent dans le temps. Ce code a ete utilise pour simuler un accident LOCA dans un reacteur nucleaire de type

  8. Les déplacements domicile-travail structurent-ils encore les territoires ?

    Directory of Open Access Journals (Sweden)

    Jean-Marc Zaninetti

    2017-12-01

    Full Text Available Introduite en France dans le recensement de 1968, la mesure des déplacements domicile-travail s’est imposée comme le critère exclusif de définition de structuration des territoires par les aires urbaines. Toutefois, le processus de para-urbanisation généralisée du territoire constaté en région Centre – Val de Loire entre 1990 et 2011 remet en cause la pertinence du recensement pour la mesure des mobilités professionnelles habituelles et la structuration urbaine du territoire.

  9. Study of a method of detection for natural carbon-14 using a liquid scintillator, recent variations in the natural radio-activity due to artificial carbon-14 (1963); Etude d'une methode de detection du carrons 14 naturel, utilisant un scintillateur liquide - variations recentes de l'activite naturelle dues au carbone 14 artificiel (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Leger, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    Among the various natural isotopes of carbon, a radioactive isotope, carbon-14, is formed by the action of secondary neutrons from cosmic rays on nitrogen in the air. Until 1950, the concentration of this isotope in ordinary carbon underwent weak fluctuations of about 2-3 per cent. The exact measurement of this concentration 6 X 10{sup 12} Ci/gm of carbon, and of its fluctuations, are difficult and in the first part of this report a highly sensitive method is given using a liquid scintillator. Since 1950 this natural activity has shown large fluctuations because of the carbon-14 formed during nuclear explosions, and in the second part, the evolution in France of this specific activity of carbon in the atmosphere and biosphere is examined. In the last part is studied the local increase in carbon activity in the atmosphere around the Saclay site, an increase caused by the carbon-14 given off as C{sup 14}O{sub 2}, by the reactors cooled partially with exterior air. (author) [French] Parmi les differents isotopes naturels du carbone, un isotope radioactif, le carbone 14, est forme par l'action de neutrons secondaires due aux rayons cosmiques sir l'azote de l'air. Jusqu'en 1950, la concentration de cet isotope dans le carbone ordinaire est soumise a des fluctuations de faible amplitude, de l'ordre de 2 a 3 pour cent. Les mesures precises de cette concentration, 6. 10{sup -12} Ci/g de carbone, et de ses fluctuations sont delicates, et dans la premiere partie de ce rapport, on decrit une methode de detection a grande sensibilite utilisant un scintillateur liquide. Depuis 1950, cette activite naturelle subit des fluctuations importantes dues au carbone 14 forme lors des explosions nucleaires, et dans la seconde partie, on examine l'evolution en France de l'activite specifique du carbone de l'atmosphere et ce la biosphere. Dans la derniere partie, on etudie l'accroissement local de l'activite du carbone de l'air aux

  10. Study of a method of detection for natural carbon-14 using a liquid scintillator, recent variations in the natural radio-activity due to artificial carbon-14 (1963); Etude d'une methode de detection du carrons 14 naturel, utilisant un scintillateur liquide - variations recentes de l'activite naturelle dues au carbone 14 artificiel (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Leger, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    Among the various natural isotopes of carbon, a radioactive isotope, carbon-14, is formed by the action of secondary neutrons from cosmic rays on nitrogen in the air. Until 1950, the concentration of this isotope in ordinary carbon underwent weak fluctuations of about 2-3 per cent. The exact measurement of this concentration 6 X 10{sup 12} Ci/gm of carbon, and of its fluctuations, are difficult and in the first part of this report a highly sensitive method is given using a liquid scintillator. Since 1950 this natural activity has shown large fluctuations because of the carbon-14 formed during nuclear explosions, and in the second part, the evolution in France of this specific activity of carbon in the atmosphere and biosphere is examined. In the last part is studied the local increase in carbon activity in the atmosphere around the Saclay site, an increase caused by the carbon-14 given off as C{sup 14}O{sub 2}, by the reactors cooled partially with exterior air. (author) [French] Parmi les differents isotopes naturels du carbone, un isotope radioactif, le carbone 14, est forme par l'action de neutrons secondaires due aux rayons cosmiques sir l'azote de l'air. Jusqu'en 1950, la concentration de cet isotope dans le carbone ordinaire est soumise a des fluctuations de faible amplitude, de l'ordre de 2 a 3 pour cent. Les mesures precises de cette concentration, 6. 10{sup -12} Ci/g de carbone, et de ses fluctuations sont delicates, et dans la premiere partie de ce rapport, on decrit une methode de detection a grande sensibilite utilisant un scintillateur liquide. Depuis 1950, cette activite naturelle subit des fluctuations importantes dues au carbone 14 forme lors des explosions nucleaires, et dans la seconde partie, on examine l'evolution en France de l'activite specifique du carbone de l'atmosphere et ce la biosphere. Dans la derniere partie, on etudie l'accroissement local de l'activite du carbone de l'air aux environs du site de Saclay, accroissement provoque par le

  11. Par Pond vegetation status Summer 1995 -- Summary

    International Nuclear Information System (INIS)

    Mackey, H.E. Jr.; Riley, R.S.

    1996-01-01

    The water level of Par Pond was lowered approximately 20 feet in mid-1991 in order to protect downstream residents from possible dam failure suggested by subsidence on the downstream slope of the dam and to repair the dam. This lowering exposed both emergent and nonemergent macrophyte beds to drying conditions resulting in extensive losses. A survey of the newly emergent, shoreline aquatic plant communities of Par Pond began in June 1995, three months after the refilling of Par Pond to approximately 200 feet above mean sea level. These surveys continued in July, September, and late October, 1995. Communities similar to the pre-drawdown, Par Pond aquatic plant communities are becoming re-established. Emergent beds of maidencane, lotus, waterlily, and watershield are extensive and well developed. Cattail occurrence continued to increase during the summer, but large beds common to Par Pond prior to the drawdown have not formed. Estimates from SPOT HRV, remote sensing satellite data indicated that as much as 120 hectares of emergent wetlands vegetation may have been present along the Par Pond shoreline by early October, 1995. To track the continued development of macrophytes in Par Pond, future surveys throughout 1996 and 1997, along with the continued evaluation of satellite data to map the areal extent of the macrophyte beds of Par Pond, are planned

  12. adaptation et selection de varietes performantes de riz pluvi

    African Journals Online (AJOL)

    PROJET SOJA

    L'absorption d'eau [5] par un composite à matrice organique dépend de plusieurs paramètres tels que : ... La détermination de la cinétique d'absorption d'eau du matériau étudié a été effectuée par une mesure de reprise de poids en fonction du ... R : constante des gaz parfaits,. Ed : énergie d'activation du processus de ...

  13. Création d'outils pour la mesure de l'intégration des technologies de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    En collaborant avec les ministères de l'Éducation de la Colombie, du Mexique, du Pérou et de l'Uruguay, les chercheurs élaboreront des méthodologies communes et des indicateurs pertinents localement en vue de surveiller et de mesurer l'intégration des TIC en classe. Les résultats obtenus fourniront aux décideurs les ...

  14. Measurements with a Pulsed and Modulated Source in a Reactor; Mesures au Moyen d'une Source Pulsee et Modulee dans un Reacteur; Izmereniya v reaktore s pomoshch'yu impul'snogo i moduliruemogo is tochnika; Mediciones Efectuadas en Reactor con una Fuente Pulsada y Modulada

    Energy Technology Data Exchange (ETDEWEB)

    Rotter, W. [Centre d' Etude de l' Energie Nucleaire, Mol (Belgium)

    1965-10-15

    a digital computer [French] Un generateur dont le debit neutronique est variable selon une fonction du temps quelconque a ete mis au point par les Laboratoires de recherches Philips. Son utilite pratique dans le domaine de la physique des reacteurs a ete demontree par une serie de mesures effectuees dans le reacteur BRO2 a fotat sous-critique. Sa bonne stabilite, la possibilite de faire varier brusquement l'intensite neutronique, de puiser le debit ou de le moduler sinusoldalement, rend ce generateur tres souple. Il permet de determiner la reactivite ({rho} = {Delta}k/{beta}) et le temps de vie des neutrons ( Script-Small-L /{beta}) d'apres differentes methodes independantes. Une comparaison exacte de ces methodes est possible puisqu'elles peuvent etre employees sans modifier les conditions de mesure. On a determine: a) {rho} sur la base des neutrons retardes, par une reduction instantanee du debit de neutrons; b) {rho} sur la base des neutrons instantanes par des bouffees de neutrons; c) Script-Small-L /{beta} par combinaison de a) et b) pour 0,5 $ < {rho} <2 $; d) Script-Small-L /{beta} sur la base de la fonction de transfert du reacteur pour une source modulee. Les fonctions de transfert pour un oscillateur de reactivite et pour une source modulee sinusoldalement sont discutees. Il est montre que la mesure de Script-Small-L /{beta} est possible pour 0,1 $ < {rho} < 10 $ en utilisant une source modulee. La meme methode fournit aussi la reactivite a l'aide du rapport des neutrons instantanes aux neutrons retardes pour une frequence optimale, pratiquement independamment des donnees relatives aux neutrons retardes et de la valeur de f Script-Small-L /{beta}. Par accumulation d'un grand nombre de cycles dans l'analyseur multicanal, la statistique peut etre amelioree pour chaque methode. Le debit du generateur etant bien sinusoiedal, la reponse du reacteur peut etre integree sur chaque quart d'une periode, etant donne que la chafhe de mesure est pilotee par le

  15. ParABS system in chromosome partitioning in the bacterium Myxococcus xanthus.

    Directory of Open Access Journals (Sweden)

    Antonio A Iniesta

    Full Text Available Chromosome segregation is an essential cellular function in eukaryotic and prokaryotic cells. The ParABS system is a fundamental player for a mitosis-like process in chromosome partitioning in many bacterial species. This work shows that the social bacterium Myxococcus xanthus also uses the ParABS system for chromosome segregation. Its large prokaryotic genome of 9.1 Mb contains 22 parS sequences near the origin of replication, and it is shown here that M. xanthus ParB binds preferentially to a consensus parS sequence in vitro. ParB and ParA are essential for cell viability in M. xanthus as in Caulobacter crescentus, but unlike in many other bacteria. Absence of ParB results in anucleate cells, chromosome segregation defects and loss of viability. Analysis of ParA subcellular localization shows that it clusters at the poles in all cells, and in some, in the DNA-free cell division plane between two chromosomal DNA masses. This ParA localization pattern depends on ParB but not on FtsZ. ParB inhibits the nonspecific interaction of ParA with DNA, and ParA colocalizes with chromosomal DNA only when ParB is depleted. The subcellular localization of ParB suggests a single ParB-parS complex localized at the edge of the nucleoid, next to a polar ParA cluster, with a second ParB-parS complex migrating after the replication of parS takes place to the opposite nucleoid edge, next to the other polar ParA cluster.

  16. Detection and location of can rupture in reactors cooled by a flow of water; Detection et localisation des ruptures de gaines sur les reacteurs refroidis par circulation d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Le Meur, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    This report brings together the principal methods of fission-product detection used for water reactors. The position, type and method of adjustment is given for each detector. The methods for localizing the defective elements are explained, in particular those using water sampling or decreases in the flux. A few installations are briefly described. They correspond to particular types of reactors using boiling, pressurized or cold water. Amongst the many methods used, it can be noted that when the fuel is resistant, the installations are fairly compact. In nuclear super-heated reactors on the other hand, the study of fuel behaviour calls for larger installations. An identification of defective elements exists when the reactor structure allows it. If this is not possible, a localization in a group of elements is obtained by a flux depression. (author) [French] Ce rapport rassemble les principales methodes de detection de produits de fission utilisees pour des reacteurs a eau. On indique pour les detecteurs leurs emplacements, leurs types, leurs reglages. On explique quelles sont les methodes de localisation des elements defectueux, en particulier celles utilisant des prelevements d'eau ou des depressions de flux. Quelques installations sont decrites sommairement. Elles correspondent a des types particuliers de reacteurs a eau bouillante, pressurisee ou froide. Parmi les nombreuses methodes utilisees, on constate que les installations sont peu importantes, lorsque le combustible est resistant. Par contre dans les reacteurs a surchauffe nucleaire l'etude du comportement du combustible necessite des installations plus importantes. Une identification d'elements defectueux existe lorsque la structure du reacteur le permet. A defaut une localisation dans un groupe d'elements est obtenue par depression de flux. (auteur)

  17. Spectral study of the luminescence produced by the excitation of noble gases by alpha-rays; Etude spectrale de la luminescence due a l'excitation des gaz rares par les rayons alpha

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Luminescence spectra of the noble gases He, A, Kr and Xe are studied under excitation by {alpha} rays. It is shown that the energy is transferred from excited levels of these gases to Hg and N{sub 2} impurities for impurity concentrations respectively less than 10{sup 6} and 10{sup 4}. These results confirm previous measurements concerning the period of luminescence and its variations versus nitrogen concentration in noble gases. (author) [French] On etudie les spectres de luminescence des gaz rares, He, A, Kr et Xe excites par une source intense de rayons {alpha}. Le transfert d'energie des etats excites des gaz rares sur les impuretes mercure et azote pour des concentrations respectives de ces impuretes inferieures a 1 ppm et 100 ppm est demontre. Ces resultats confirment les mesures anterieures concernant la duree de luminescence et ses variations avec la concentration d'azote dans les gaz rares. (auteur)

  18. Contribution to the study of detonation initiation by shock in solid explosives (1961); Contribution a l'etude de l'initiation de la detonation par choc dans les explosifs solides (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Fauquignon, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-05-15

    When a shock wave is induced in an explosive, it can initiate chemical reactions which lead more or less rapidly to a stable detonation state. In this study more particular attention was paid to the transition phase, in which has been evaluated the increases in the wave velocity, the pressure, and the electrical conductivity. The influence of the nature of the medium in front of the wave and in contact with the explosive has also been the subject of an experimental study designed to determine the extent to which its nature can be ignored and, subsequently, to characterise the initiation conditions using only the shock intensity induced in the explosive. Finally, the results were generalized for various explosive compositions and led to the development of a possible mechanism for shock initiation. (author) [French] Lorsqu'une onde de choc est induite dans un explosif, elle peut y amorcer des reactions chimiques qui conduisent plus ou moins rapidement a un regime de detonation stable. Dans cette etude, on s'est interesse plus particulierement a la phase transitoire dans laquelle on a evalue l'accroissement de la vitesse d'onde, de la pression et de la conductibilite electrique. L'influence du milieu amont, au contact de l'explosif, a egalement fait l'objet de recherches experimentales de facon a determiner dans quelle mesure on pouvait s'affranchir de sa nature et, par suite, caracteriser les conditions d'initiation par la seule intensite du choc induit dans l'explosif. Enfin, les resultats ont ete generalises a diverses compositions explosives et ont conduit a l'elaboration d'un schema possible du mecanisme de l'initiation par choc. (auteur)

  19. General trends in the use of uranium in the nuclear industry; Tendances generales d'emploi de l'uranium dans les industries nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Salesse, M [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    It can be seen from a consideration of the development of the military and civil needs for uranium that, in the long run, the main outlet for the metal will be provided by its industrial applications. The technical uncertainties concerning the best method of producing atomic energy are still numerous and in fact reflect the hesitation in choosing one of two classes of fuel: that based on the metal and that based on the oxide. Four main factors should influence the choice: - the neutron reactivity and the enrichment of the uranium; - the operating temperature; - the resistance to radiation effects; - the chemical stability; but in actual fact, when the choice for a particular use has to be made, it will be another type of factor, such as the cost price, and weight and space considerations which will determine the choice of either metallic uranium or uranium oxide reactors. (author) [French] D'apres le developpement des besoins militaires ou civils en uranium, on voit que les usages industriels de ce metal constituent, a long terme, le debouche essentiel. Les incertitudes techniques, sur le procede optimum pour faire de l'energie nucleaire, restent nombreuses, et se traduisent finalement par une hesitation entre deux grandes classes de combustibles: ceux a base de metal et ceux a base d'oxyde: la preference a l'une ou l'autre de ces deux categories doit s'inspirer de quatre considerations: - la reactivite neutronique et l'enrichissement de l'uranium; - la temperature de fonctionnement; - la resistance aux effets du rayonnement; - la stabilite chimique; mais en definitive, lorsqu'il s'agira d'une application determinee, ce seront des considerations d'un autre ordre, comme le prix de revient, le poids et l'encombrement, qui determineront le choix entre piles a uranium metallique et piles a oxyde d'uranium. (auteur)

  20. Exit this way; Par ici la sortie du nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This paper aims to inform the public on the nuclear power phaseout necessity. The fist part presents the hazards bound the nuclear activities, from the uranium mines to the radioactive wastes disposal and the reasons of a necessary phaseout. The second part recalls the historical aspects of the nuclear power implementation in the french energy policy and the today government attitude to value its choice. The last part presents the advantages of other energies sources and scenario of nuclear power phaseout. (A.L.B.)

  1. Adjustment of a direct method for the determination of man body burden in Pu-239 on by X-ray detection of U-235; Mise au point d'une methode directe de determination de la charge corporelle en plutonium 239 chez l'homme par detection X de l'uranium 235

    Energy Technology Data Exchange (ETDEWEB)

    Boulay, P [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1968-04-01

    The use of Pu-239 on a larger scale sets a problem about the contamination measurement by aerosol at lung level. A method of direct measurement of Pu-239 lung burden is possible, thanks to the use of a large area window proportional counter. A counter of such pattern, has been especially carried out for this purpose. The adjustment of the apparatus allows an adequate sensibility to detect a contamination at the maximum permissible body burden level. Besides, a method for individual 'internal calibration', with a plutonium mock: the protactinium-233, is reported. (author) [French] L'utilisation a une echelle de plus en plus large du plutonium-239 pose un probleme de la mesure de la contamination par aerosol au niveau du poumon. Une methode de mesure directe de la charge pulmonaire en plutonium-239 est possible grace a l'utilisation d'un compteur proportionnel a fenetre de grande surface. Un compteur de ce type a specialement ete realise dans ce but. La mise au point de l'appareillage permet une sensibilite suffisante pour deceler une contamination au niveau de la Q.M.A (quantite maximale admissible). D'autre part, une methode 'd'etalonnage interne' de l'individu a l'aide d'un simulateur de plutonium, le protactinium-233, est decrite. (auteur)

  2. Évolution de la surface de plasticité sous chargement biaxial dans un acier inoxydable duplex

    Science.gov (United States)

    Aubin, V.; Quaegebeur, P.; Degallaix, S.

    2002-12-01

    Nous proposons une méthodologie de mesure automatique de la surface de plasticité pendant des chargements cycliques biaxiaux. La surface de plasticité est mesurée de manière discrète avec un faible offset de déformation plastique (2 10^{-5}) et des paramètres de mesure optimisés. La méthode est appliquée à un acier inoxydable duplex soumis à un trajet de chargement non-proportionnel. Les résultats montrent une distorsion et une translation de la surface de plasticité sans changement de taille. La méthode présentée permet également de vérifier la normalité de la vitesse d'écoulement plastique par rapport à la surface de plasticité.

  3. L'état de l'environnement industriel français est-il objectivement mesurable ?

    OpenAIRE

    Gotteland, David; Boulé, Jean-Marie

    2004-01-01

    Working paper serie RMT (WPS 04-07); the environmental state is a frequently modelized variable in marketing research. This paper proposes updated scales and panorama of the objective state of 58 industrial branches defined by INSEE based on three characteristic dimensions: dynamism, complexity and capacity.; l'état de l'environnement est une variable fréquemment modélisée dans la recherche en marketing. A partir de ce constat, cet article propose une échelle de mesure et un panorama actualis...

  4. Experience gained in gamma spectroscopy; Experience acquise dans la spectrometrie gamma

    Energy Technology Data Exchange (ETDEWEB)

    Jeanmaire, L [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    There are two types of method which make it possible to estimate the internal contamination of individuals. On the one hand these are the indirect techniques based on measurements of the excreted products, on the other there are the direct techniques in which attempts are made to measure directly the radio-activity existing in the organism. We propose to give a few of the results obtained by the direct method using equipment built by the Commissariat a l'Energie Atomique. The apparatus consists of a {gamma} spectrometer. It includes: 1) A crystal of sodium iodide 20 cm in diameter and 10 cm high. The large size of this crystal ensures a good sensitivity and makes it possible to carry out rapid measurements. 2) A 25 channel type SAE 25 selector which classifies the pulses according to their amplitude. It is therefore possible to distinguish between {gamma} rays of varying energy. 3) A comparatively very light radiation protection, consisting of only 5 cm thickness of lead which diminishes the ambient {gamma} ray intensity to a sufficient level for the majority of the measurements. A certain collimation is thus obtained which makes it possible to localise the source approximately and to reduce the undesirable effects of external contamination. (author) [French] Deux types de methodes permettent d'apprecier la contamination interne d'un individu. D'une part, les techniques indirectes basees sur la mesure des produits excretes, d'autre part, les techniques directes au moyen desquelles on essaie de mesurer directement la radioactivite existant dans l'organisme. Nous nous proposons d'indiquer quelques resultats obtenus par la methode directe, au moyen d'ensembles realises par le Commissariat a l'Energie Atomique. L'appareillage est un spectrometre {gamma}. II comprend: 1) Un cristal d'iodure de sodium de 20 cm de diametre et 10 cm de hauteur. La grande taille de ce cristal assure une bonne sensibilite et permet d'effectuer des mesures rapides. 2) Un selecteur a 25 canaux

  5. New determination of the vapour pressures of the isotopes of neon; Nouvelles determinations des tensions de vapeur des isotopes du neon

    Energy Technology Data Exchange (ETDEWEB)

    Roth, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-03-15

    We have undertaken an experimental reinvestigation of the vapor pressures of the neon isotopes over the temperature range 16.30-30.1 deg. K. Measurements were made by differential manometry in a Giauque-Johnston type cryostat modified for temperature stability. The New sample contained 99.9 % Ne{sup 20} and the Ne{sup 22} sample contained 72,2 % Ne{sup 22}. Extrapolation to pure Ne{sup 20} and Ne{sup 22} can be made with sufficient accuracy by the use of Raoult's law. Our results are in substantial agreement with those of Keesom and Haantjes. At 20 deg. K, where the scatter in our data is an order of magnitude smaller than in the data of Keesom and Haantjes, we find In P{sub Ne{sup 2}{sup 0}}/P{sub Ne{sup 2}{sup 2}} is 6 % larger than the smoothed line given by them. For solid neon, our data can be represented to a high accuracy by a Debye harmonic lattice with {theta}{sub D} (Ne{sup 20}) = 74.6 deg. K. The result may be compared with the value obtained by Henshaw from the Debye-Waller temperature factor, {theta}{sub D} = 73 deg. K, and with the recent calculation of the zero point energy of Ne by Bernardes, from which he obtains {theta}{sub D} 8E{sub {theta}}/9R = 73 deg.. K. (author) [French] On a construit un appareillage dont le principe est derive de celui des instruments decrits par GIAUQUE et EGAN ou par H.L. JOHNSTON qui a permis d'etendre le domaine des mesures de tension de vapeur des isotopes du Neon entre 16,30 et 32 deg. K environ. Le rapport des pressions extremes atteintes est ainsi multiplie par plus de 40 pour le neon ordinaire qui servait de reference et de thermometre. L'appareil, adapte en particulier au travail sous pressions elevees, permet, de plus, de travailler sur de relativement petites quantites totales de gaz - environ 500 cm{sup 3} suffisent dans l'intervalle de pression evoque. La stabilite de temperature obtenue peut etre tres bonne surtout lorsque l'on travaille dans la phase liquide; dans ce cas, les variations totales de

  6. New determination of the vapour pressures of the isotopes of neon; Nouvelles determinations des tensions de vapeur des isotopes du neon

    Energy Technology Data Exchange (ETDEWEB)

    Roth, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-03-15

    We have undertaken an experimental reinvestigation of the vapor pressures of the neon isotopes over the temperature range 16.30-30.1 deg. K. Measurements were made by differential manometry in a Giauque-Johnston type cryostat modified for temperature stability. The New sample contained 99.9 % Ne{sup 20} and the Ne{sup 22} sample contained 72,2 % Ne{sup 22}. Extrapolation to pure Ne{sup 20} and Ne{sup 22} can be made with sufficient accuracy by the use of Raoult's law. Our results are in substantial agreement with those of Keesom and Haantjes. At 20 deg. K, where the scatter in our data is an order of magnitude smaller than in the data of Keesom and Haantjes, we find In P{sub Ne{sup 2}{sup 0}}/P{sub Ne{sup 2}{sup 2}} is 6 % larger than the smoothed line given by them. For solid neon, our data can be represented to a high accuracy by a Debye harmonic lattice with {theta}{sub D} (Ne{sup 20}) = 74.6 deg. K. The result may be compared with the value obtained by Henshaw from the Debye-Waller temperature factor, {theta}{sub D} = 73 deg. K, and with the recent calculation of the zero point energy of Ne by Bernardes, from which he obtains {theta}{sub D} 8E{sub {theta}}/9R = 73 deg.. K. (author) [French] On a construit un appareillage dont le principe est derive de celui des instruments decrits par GIAUQUE et EGAN ou par H.L. JOHNSTON qui a permis d'etendre le domaine des mesures de tension de vapeur des isotopes du Neon entre 16,30 et 32 deg. K environ. Le rapport des pressions extremes atteintes est ainsi multiplie par plus de 40 pour le neon ordinaire qui servait de reference et de thermometre. L'appareil, adapte en particulier au travail sous pressions elevees, permet, de plus, de travailler sur de relativement petites quantites totales de gaz - environ 500 cm{sup 3} suffisent dans l'intervalle de pression evoque. La stabilite de temperature obtenue peut etre tres bonne surtout lorsque l'on travaille dans la phase liquide; dans ce cas, les

  7. Elaboration d’une réglementation de biosécurité par certains pays en développement: expériences dans la mise en oeuvre du Protocole de Cartagena en Afrique de l'Ouest

    Directory of Open Access Journals (Sweden)

    Christine Frison & Thomas Joie

    2006-09-01

    Full Text Available Cet article analyse l'élaboration de législations nationales adaptées et conformes au Protocole de Cartagena en matière de biotechnologie et de biosécurité par certains pays d'Afrique de l'Ouest participant au 'Projet de Développement de Cadre Nationaux de Biosécurité' du PNUE-FEM. Les auteurs tentent de dégager les perspectives de réglementation et les difficultés potentielles auxquelles ces pays pourront être confrontés. Ainsi, sont analysés les différents moyens et outils choisis par les pays ouest-africains pour répondre aux droits et obligations découlant du Protocole ainsi qu'à leurs besoins et contraintes internes. Dans la mesure où ces pays n'ont pas encore adopté de réglementation nationale, cet article s'appuie prudemment sur les cadres nationaux de biosécurité développés pour traiter des questions clés de biosécurité: les questions institutionnelles et réglementaires, les procédures de décision, la participation du public ainsi que d'autres considérations pertinentes pour ces pays.

  8. Rôle de la dispersion dans la réponse des populations de truites aux habitats formés par les grands débris ligneux dans les ruisseaux de montagne du Colorado

    Directory of Open Access Journals (Sweden)

    FAUSCH K. D.

    1995-04-01

    Full Text Available Un peu partout dans le monde, les aménagistes des pêches utilisent souvent des rondins pour réaliser des mouilles pour les salmonidés, souvent pour compenser l'absence de grands débris ligneux (LWD due à la déforestation ou à d'autres perturbations des forêts alluviales. Des mesures des LWD réalisées sur 11 ruisseaux de montagne du Colorado drainant de vieilles forêts de résineux (Picea - Abies montrent qu'ils sont à l'origine de la plupart des mouilles. Les morceaux qui contribuent à la formation des mouilles sont, en moyenne, plus grands que ceux qui n'en forment pas. La plupart enjambe le chenal perpendiculairement à l'écoulement et forme des mouilles de chute («plunge pool» et des mouilles de retenue («dammed pool». Les aménagistes des pêches qui utilisent des troncs perpendiculaires à l'écoulement pour réaliser des mouilles considèrent généralement que cette addition d'habitat améliore la survie des salmonidés résidents pendant les périodes critiques comme l'hiver. Une expérience de longue durée, réalisée pour tester cette hypothèse dans six ruisseaux de montagne du Colorado, a montré que les populations de truites résidentes augmentaient rapidement et significativement dans des portions expérimentales de 250m, par rapport à des témoins adjacents. Cependant, des mesures de la dispersion réalisées par des piégeages et des recaptures de truites marquées ont montré que les mouilles formées par des troncs augmentent les populations de truites adultes en permettant aux truites qui étaient en phase de déplacement de rester dans les portions expérimentales plutôt qu'en améliorant la survie hivernale sur place, comme le décrivent d'autres auteurs. La recherche sur les salmonidés d'eau courante non migrateurs et leur gestion a jusqu'à présent été marquée par un modèle impliquant des déplacements limités, ce qui implique que les adultes soient relativement sédentaires. Cependant, l

  9. Study methods for the drillings around the underground nuclear explosions in the Sahara. Part 1. study of rock samples; Methodes d'etude des forages realises autour des explosions nucleaires souterraines au Sahara. Premiere partie: etude des echantillons de roche

    Energy Technology Data Exchange (ETDEWEB)

    Derlich, S [Commissariat a l' Energie Atomique, Bruyers-le-Chatel (France). Centre d' Etudes

    1969-07-01

    An examination of the mechanical effects produced on rocks by an underground nuclear explosion calls for the use of particular means of exploration which are described in this report, special attention being paid to the equipment used in connection with the French nuclear tests in the Sahara. The drilling methods used (rotary and turbo-drilling) are adapted to the particular conditions of the sampling programme, to the radioactivity and to the temperature in the region of the explosion. A study of the samples makes it possible to obtain the new characteristics of the rock and to assess the chemical and mechanical transformations which it has undergone. An examination of the core obtained from the drilling, together with a knowledge of the drilling parameters (depth of the probe, sample recovery, etc...), makes it possible to study the extent and the characteristics of the zones which have been damaged to different degrees according to their distance from the zero point: cavity, strongly powdered zone, fractured zone, chimney, zones containing high stresses leading to a particular type of fracture of the cores. The problems connected with the interpretation of the results are also presented. (author) [French] L'examen des effets mecaniques provoques par une explosion nucleaire souterraine sur la roche necessite la mise en oeuvre de moyens d'exploration particuliers dont l'expose fait l'objet de ce rapport, essentiellement pour les moyens utilises autour des essais nucleaires francais au Sahara. Les methodes de forage (rotary et turboforage) sont adaptees aux conditions particulieres dues au programme d'echantillonnage, a la radioactivite et a la temperature regnant a proximite du point de tir. L'etude des echantillons permet la determination des nouveaux caracteres de la roche et de ses transformations chimique et mecanique. L'examen des carottes et l'utilisation des parametres de forage (cotes sondeurs, recuperation des echantillons, etc...) permettent d'etudier l

  10. Analysis of ParB-centromere interactions by multiplex SPR imaging reveals specific patterns for binding ParB in six centromeres of Burkholderiales chromosomes and plasmids.

    Science.gov (United States)

    Pillet, Flavien; Passot, Fanny Marie; Pasta, Franck; Anton Leberre, Véronique; Bouet, Jean-Yves

    2017-01-01

    Bacterial centromeres-also called parS, are cis-acting DNA sequences which, together with the proteins ParA and ParB, are involved in the segregation of chromosomes and plasmids. The specific binding of ParB to parS nucleates the assembly of a large ParB/DNA complex from which ParA-the motor protein, segregates the sister replicons. Closely related families of partition systems, called Bsr, were identified on the chromosomes and large plasmids of the multi-chromosomal bacterium Burkholderia cenocepacia and other species from the order Burkholeriales. The centromeres of the Bsr partition families are 16 bp palindromes, displaying similar base compositions, notably a central CG dinucleotide. Despite centromeres bind the cognate ParB with a narrow specificity, weak ParB-parS non cognate interactions were nevertheless detected between few Bsr partition systems of replicons not belonging to the same genome. These observations suggested that Bsr partition systems could have a common ancestry but that evolution mostly erased the possibilities of cross-reactions between them, in particular to prevent replicon incompatibility. To detect novel similarities between Bsr partition systems, we have analyzed the binding of six Bsr parS sequences and a wide collection of modified derivatives, to their cognate ParB. The study was carried out by Surface Plasmon Resonance imaging (SPRi) mulitplex analysis enabling a systematic survey of each nucleotide position within the centromere. We found that in each parS some positions could be changed while maintaining binding to ParB. Each centromere displays its own pattern of changes, but some positions are shared more or less widely. In addition from these changes we could speculate evolutionary links between these centromeres.

  11. Keratometric alterations following the 25-gauge transconjunctival sutureless pars plana vitrectomy versus the conventional pars plana vitrectomy.

    Science.gov (United States)

    Citirik, Mehmet; Batman, Cosar; Bicer, Tolga; Zilelioglu, Orhan

    2009-09-01

    To assess the alterations in keratometric astigmatism following the 25-gauge transconjunctival sutureless pars plana vitrectomy versus the conventional pars plana vitrectomy. Sixteen consecutive patients were enrolled into the study. Conventional vitrectomy was applied to eight of the cases and 25-gauge transconjunctival sutureless vitrectomy was performed in eight patients. Keratometry was performed before and after the surgery. In the 25-gauge transconjunctival sutureless pars plana vitrectomy group, statistically significant changes were not observed in the corneal curvature in any post-operative follow-up measurement (p > 0.05); whereas in the conventional pars plana vitrectomy group, statistically significant changes were observed in the first postoperative day (p = 0.01) and first postoperative month (p = 0.03). We noted that these changes returned to baseline in three months (p = 0.26). Both 25-gauge transconjunctival sutureless and conventional pars plana vitrectomy are effective surgical modalities for selected diseases of the posterior segment. Surgical procedures are critical for the visual rehabilitation of the patients. The post-operative corneal astigmatism of the vitrectomised eyes can be accurately determined at least two months post-operatively.

  12. Caractéristiques, menaces et nécessité de conservation in situ du ...

    African Journals Online (AJOL)

    SARAH

    30 sept. 2015 ... Le contrôle et la limitation de son absorption par le sang zébu sont ... breeding performance of Baoulé taurine cattle, to show its ... zones de savane et dans une moindre mesure ...... conservation et de la gestion des stocks.

  13. in blood transfusion

    African Journals Online (AJOL)

    gestion de la transfusion des patients se traduit par une diminution spectaculaire de .... lABoRAToRy pERFoRMANCE ChECKs ... CoNTRôlEs DE pERFoRMANCE DE ...... mesure de fournir des packs ayant un faible volume de sang et une.

  14. 2773-IJBCS-Article-Mokho Sarr

    African Journals Online (AJOL)

    hp

    et en zone sèche, pour le contrôle des piqueurs suceurs. Les innovations peuvent ... par la gestion sur seuil et le positionnement de matières actives est ... Observation et mesure. Des relevés ..... des performances agronomiques du cotonnier ...

  15. Experimental measurement of fission fragments paths in uranium gold, molybdenum, zirconium and silicon; Mesure experimentale des parcours des fragments de fission dans l'uranium, l'or, le molybdene, le zirconium et le silicium

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, H; Garin-Bonnet, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measurement of total number of fissiongments emerging from an homogeneous, thick alloy composed of uranium plus another element (the concentration of uranium being known) allows to obtain the range of the fragments in this alloy. By varying the concentration, the range of the fragments in uranium and in the other element can be deduced. (author)Fren. [French] La mesure du nombre total de fragments de fission sortant d'un alliage homogene epais d'uranium et d'un autre element, pour lequel la concentration en uranium est donnee, permet la mesure du parcours des fragments dans cet alliage. En faisant varier la concentration, on peut deduire de ces mesures le parcours des fragments dans l'uranium et dans l'autre element. (auteur)

  16. Centromere pairing by a plasmid-encoded type I ParB protein

    DEFF Research Database (Denmark)

    Ringgaard, Simon; Löwe, Jan; Gerdes, Kenn

    2007-01-01

    The par2 locus of Escherichia coli plasmid pB171 encodes two trans-acting proteins, ParA and ParB, and two cis-acting sites, parC1 and parC2, to which ParB binds cooperatively. ParA is related to MinD and oscillates in helical structures and thereby positions ParB/parC-carrying plasmids regularly......, hence identifying the N terminus of ParB as a requirement for ParB-mediated centromere pairing. These observations suggest that centromere pairing is an important intermediate step in plasmid partitioning mediated by the common type I loci....

  17. Magnétochiralité et résonances stochastiques dans les lasers

    Science.gov (United States)

    Bonnet, C.; Bretenaker, F.; Brunel, M.; Chauvat, D.; Emile, O.; Lai, N. D.; Le Floch, A.; Ropars, G.; Ruchon, T.; Singh, K.; Thépot, J.-Y.; Vallet, M.

    2002-06-01

    Les états propres d'un laser constituent un outil de choix pour étudier les différents rôles joués par le bruit dans un système. D'une part, si on veut isoler un effet petit difficilement accessible par les méthodes classiques, ces états propres permettent de réaliser des mesures différentielles de haute précision, à condition de pouvoir éliminer les bruits mécaniques, optiques, électroniques. A titre d'exemple, nous avons utilisé les états propageant et contrapropageant d'un laser ionique en anneau pour mesurer une interaction fondamentale faible: la biréfringence magnétochirale. Cette "biréfringence" se manifeste en effet par une petite variation d'indice selon le sens de parcours de l'anneau, de l'ordre de Δ n.10^{-11}, indépendante de la polarisation. A l'opposé, les deux états propres d'un laser du type Fabry-Perot constituent un système idéal pour explorer les résonances stochastiques à deux dimensions. Les résonances stochastiques par inhibition et par rotation sont isolées en présence de bruits blancs gaussiens tant pour les bruits optiques que magnétiques. L'utilisation possible de l'émission spontanée comme bruit actif est démontrée.

  18. Analysis of ParB-centromere interactions by multiplex SPR imaging reveals specific patterns for binding ParB in six centromeres of Burkholderiales chromosomes and plasmids.

    Directory of Open Access Journals (Sweden)

    Flavien Pillet

    Full Text Available Bacterial centromeres-also called parS, are cis-acting DNA sequences which, together with the proteins ParA and ParB, are involved in the segregation of chromosomes and plasmids. The specific binding of ParB to parS nucleates the assembly of a large ParB/DNA complex from which ParA-the motor protein, segregates the sister replicons. Closely related families of partition systems, called Bsr, were identified on the chromosomes and large plasmids of the multi-chromosomal bacterium Burkholderia cenocepacia and other species from the order Burkholeriales. The centromeres of the Bsr partition families are 16 bp palindromes, displaying similar base compositions, notably a central CG dinucleotide. Despite centromeres bind the cognate ParB with a narrow specificity, weak ParB-parS non cognate interactions were nevertheless detected between few Bsr partition systems of replicons not belonging to the same genome. These observations suggested that Bsr partition systems could have a common ancestry but that evolution mostly erased the possibilities of cross-reactions between them, in particular to prevent replicon incompatibility. To detect novel similarities between Bsr partition systems, we have analyzed the binding of six Bsr parS sequences and a wide collection of modified derivatives, to their cognate ParB. The study was carried out by Surface Plasmon Resonance imaging (SPRi mulitplex analysis enabling a systematic survey of each nucleotide position within the centromere. We found that in each parS some positions could be changed while maintaining binding to ParB. Each centromere displays its own pattern of changes, but some positions are shared more or less widely. In addition from these changes we could speculate evolutionary links between these centromeres.

  19. Radioactive equilibrium of uranium-bearing ores in some problems of applied geology; Les equilibres radioactifs des menerais uraniferes dans quelques problemes de geologie appliquee

    Energy Technology Data Exchange (ETDEWEB)

    Coulomb, R; Girard, Ph; Goldsztein, M [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The state of equilibrium between several nuclides in radioactive relationship is determined with accuracy by the fundamental equations of radioactivity. It can be measured physically and expressed in suitable and internationally adopted units; Equilibrium - disequilibrium of uranium-bearing ores is a fairly complex phenomenon but the problem can be much simplified by well-chosen approximations in various practical field cases. The results of radiometric and radiochemical measurements lead to the interpretation of geochemical anomalies and may be used in the qualitative and quantitative estimation of uranium bearing deposits. (authors) [French] L'etat d'equilibre entre plusieurs radioelements en filiation se definit avec precision par les equations fondamentales de la radioactivite et peut etre determine par des mesures physiques dans des systemes d'unites commodes et internationalement adoptes. Le probleme general equilibre-desequilibre des minerais uraniferes est relativement complexe, mais peut se simplifier largement par des approximations judicieuses dans de nombreux cas particuliers rencontres concretement sur le terrain. Les resultats des mesures radiometriques et radiochimiques permettent l'interpretation des anomalies geochimiques et peuvent servir a l'estimation qualitative et quantitative des gisements de minerais uraniferes. (auteurs)

  20. Les OPCVM actions au Maroc : mesure et analyse de performance-risque

    Directory of Open Access Journals (Sweden)

    F. El Majidi

    2017-09-01

    Full Text Available Cet article a pour objet d’élaborer des classements des OPCVM actions au Maroc sur un an et sur cinq ans selon la performance, le risque et le ratio risque rentabilité. On a utilisé les données figurant sur les tableaux des performances publiés par l’ASFIM. Les calculs des performances sur les deux horizons montrent que les classements des fonds ne se distinguent pas en termes des performances absolues et celles relatives à contrario on a constaté une instabilité dans les classements d’un horizon à un autre. Le nombre de fonds réalisant des performances sur une année est supérieur au nombre de fonds dont la performance est calculée sur cinq ans aussi bien en termes absolu qu’en termes relatif. Enfin, le classement par le ratio risque rentabilité est rigoureux, il diffère de ceux par les performances car les fonds changent de positions et se distinguent par leurs risques inhérents.

  1. CFD analysis of PAR performance as function of inlet design

    International Nuclear Information System (INIS)

    Park, Kweonha; Khor, Chong Lee

    2016-01-01

    Highlights: • The new concept of PAR (passive autocatalytic recombiner) was proposed and analyzed. • Guidance wall was added at the bottom of PAR to enhance the flow rate through the catalyst. • The new concept of PAR was proved to have a better hydrogen removal performance. - Abstract: Passive autocatalytic recombiner (PAR) is very useful hydrogen mitigation measurement. It is widely implemented in the current and advanced light water reactors (ALWRs). The design of the PARs should be optimized for the specific use under severe accident scenarios. Several techniques and innovations have been fused into the PAR, as an effort to increase its efficiency of hydrogen mitigation. This study proposes different concepts of PAR, which applied some changes to the honeycomb catalyst PAR made by the Korea Nuclear Technology (KNT) Inc. Two slices of plate are added to the bottom of PAR model, which intended to act as a reflection wall and promote the gas flow into PAR. Hydrogen volume fraction was given 4 vol. % which tested by KNT to investigate the performance of PAR in different direction gas flow conditions to see maximum hydrogen recombination rate. The new concept of PAR was proved to have a better hydrogen removal performance compared to the original honeycomb catalyst PAR.

  2. CFD analysis of PAR performance as function of inlet design

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kweonha, E-mail: khpark@kmou.ac.kr [Division of Mechanical and Energy systems Engineering, Korea Maritime University, Dongsam-dong, Yeongdo-gu, Busan 606-791 (Korea, Republic of); Khor, Chong Lee, E-mail: itachi_829@hotmail.com [Department of Mechanical Engineering, Korea Maritime University (Korea, Republic of)

    2016-01-15

    Highlights: • The new concept of PAR (passive autocatalytic recombiner) was proposed and analyzed. • Guidance wall was added at the bottom of PAR to enhance the flow rate through the catalyst. • The new concept of PAR was proved to have a better hydrogen removal performance. - Abstract: Passive autocatalytic recombiner (PAR) is very useful hydrogen mitigation measurement. It is widely implemented in the current and advanced light water reactors (ALWRs). The design of the PARs should be optimized for the specific use under severe accident scenarios. Several techniques and innovations have been fused into the PAR, as an effort to increase its efficiency of hydrogen mitigation. This study proposes different concepts of PAR, which applied some changes to the honeycomb catalyst PAR made by the Korea Nuclear Technology (KNT) Inc. Two slices of plate are added to the bottom of PAR model, which intended to act as a reflection wall and promote the gas flow into PAR. Hydrogen volume fraction was given 4 vol. % which tested by KNT to investigate the performance of PAR in different direction gas flow conditions to see maximum hydrogen recombination rate. The new concept of PAR was proved to have a better hydrogen removal performance compared to the original honeycomb catalyst PAR.

  3. Par Pond Fish, Water, and Sediment Chemistry

    International Nuclear Information System (INIS)

    Paller, M.H.; Wike, L.D.

    1996-06-01

    The objectives of this report are to describe the Par Pond fish community and the impact of the drawdown and refill on the community, describe contaminant levels in Par Pond fish, sediments, and water and indicate how contaminant concentrations and distributions were affected by the drawdown and refill, and predict possible effects of future water level fluctuations in Par Pond

  4. Par Pond Fish, Water, and Sediment Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Paller, M.H. [Westinghouse Savannah River Company, AIKEN, SC (United States); Wike, L.D.

    1996-06-01

    The objectives of this report are to describe the Par Pond fish community and the impact of the drawdown and refill on the community, describe contaminant levels in Par Pond fish, sediments, and water and indicate how contaminant concentrations and distributions were affected by the drawdown and refill, and predict possible effects of future water level fluctuations in Par Pond.

  5. Concerning the dynamic instability of actin homolog ParM

    International Nuclear Information System (INIS)

    Popp, David; Yamamoto, Akihiro; Iwasa, Mitsusada; Narita, Akihiro; Maeda, Kayo; Maeda, Yuichiro

    2007-01-01

    Using in vitro TIRF- and electron-microscopy, we reinvestigated the dynamics of native ParM, a prokaryotic DNA segregation protein and actin homolog. In contrast to a previous study, which used a cysteine ParM mutant, we find that the polymerization process of wild type ATP-ParM filaments consists of a polymerization phase and a subsequent steady state phase, which is dynamically unstable, like that of microtubules. We find that the apparent bidirectional polymerization of ParM, is not due to the intrinsic nature of this filament, but results from ParM forming randomly oriented bundles in the presence of crowding agents. Our results imply, that in the bacterium, ParM filaments spontaneously form bipolar bundles. Due to their intrinsic dynamic instability, ParM bundles can efficiently 'search' the cytoplasmic lumen for DNA, bind it equally well at the bipolar ends and segregate it approximately symmetrically, by the insertion of ParM subunits at either end

  6. First-in-human uPAR PET

    DEFF Research Database (Denmark)

    Persson, Morten; Skovgaard, Dorthe; Brandt-Larsen, Malene

    2015-01-01

    A first-in-human clinical trial with Positron Emission Tomography (PET) imaging of the urokinase-type plasminogen activator receptor (uPAR) in patients with breast, prostate and bladder cancer, is described. uPAR is expressed in many types of human cancers and the expression is predictive...... for targeted molecular imaging with PET. The safety, pharmacokinetic, biodistribution profile and radiation dosimetry after a single intravenous dose of (64)Cu-DOTA-AE105 were assessed by serial PET and computed tomography (CT) in 4 prostate, 3 breast and 3 bladder cancer patients. Safety assessment...... of invasion, metastasis and indicates poor prognosis. uPAR PET imaging therefore holds promise to be a new and innovative method for improved cancer diagnosis, staging and individual risk stratification. The uPAR specific peptide AE105 was conjugated to the macrocyclic chelator DOTA and labeled with (64)Cu...

  7. uPAR as anti-cancer target

    DEFF Research Database (Denmark)

    Lund, Ida K; Illemann, Martin; Thurison, Tine

    2011-01-01

    , and a potential diagnostic and predictive impact of the different uPAR forms has been reported. Hence, pericellular proteolysis seems to be a suitable target for anti-cancer therapy and numerous approaches have been pursued. Targeting of this process may be achieved by preventing the binding of uPA to u...... using mouse monoclonal antibodies (mAbs) against mouse uPA or uPAR. These reagents will target uPA and uPAR in both stromal cells and cancer cells, and their therapeutic potential can now be assessed in syngenic mouse cancer models....

  8. Development of a power-period calculation unit for nuclear reactor Control; Etude et realisation d'un ensemble de calcul puissance periode pour le controle d'un reacteur nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-10-01

    The apparatus studied is a digital calculating assembly which makes it possible to prepare and to present numerically the period and power of a nuclear reactor during operation, from start-up to nominal power. The pulses from a fission chamber are analyzed continuously, using real time. A small number of elements is required because of the systematic use of a calculation technique comprising the determination of a base 2 logarithm by a linear approximation. The accuracy obtained for the period is of the order of 14%; the response time of the order of the calculated period value. An approximate value of the power (30%) is given at each calculation cycle together with the power thresholds required for the control. (author) [French] L'appareil etudie est un ensemble de calcul digital permettant d'elaborer et d'afficher numeriquement la periode et la puissance, d'un reacteur nucleaire lors de son fonctionnement depuis le demarrage jusqu'a la puissance nominale. Il traite en temps reel, de facon continue, les impulsions en provenance d'une chambre de fission. Grace a l'utilisation systematique d'une technique de calcul, la determination d'un logarithme a base 2 par approximation lineaire, un nombre reduit d'elements est utilise. La precision obtenue sur la periode est de l'ordre de 14 pour cent, le temps de reponse de l'ordre de la valeur de la periode calculee. Un ordre de grandeur de la puissance (30 pour cent) est donne a chaque cycle de calcul ainsi que des seuils de puissance necessaires au controle. (auteur)

  9. Temperature measurements in thermonuclear plasmas; Mesures des temperatures dans les plasmas thermonucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The temperatures needed to produce thermonuclear reactions are of the order of several million degrees Kelvin. Devising methods for measuring such temperatures has been the subject of research in many countries. In order to present the problem clearly and to demonstrate its importance, the author reviews the various conditions which must be fulfilled in order that reactions may be qualified as thermonuclear. The relationship between the temperature and the cross-section of the reactions is studied, and it is shown that the notion of temperature in the plasmas is complex, which leads to a consideration of the temperature of the ions and that of the electrons. None of the methods for the temperature measurements is completely satisfactory because of the hypotheses which must be made, and which are seldom fulfilled during high-intensity discharges in the plasmas. In practice it is necessary to use several methods simultaneously. (author) [French] Les temperatures necessaires pour produire des reactions thermonucleaires sont de l'ordre de plusieurs millions de degres Kelvin. Les methodes envisagees pour mesurer ces temperatures font l'objet de recherches dans de nombreux pays. Afin de preciser le probleme et de montrer son importance, l'auteur rappelle les conditions qui doivent etre reunies pour que des reactions puissent etre qualifiees thermonucleaires. Il etudie la relation entre la temperature et la section efficace des reactions et montre que la notion de temperature dans les plasmas est complexe, ce qui amene a considerer la temperature des ions et celle des electrons. Aucune des methodes de mesure des temperatures n'est completement satisfaisante en raison des hypotheses qu'elles exigent et qui sont rarement realisees lors des decharges a haute intensite dans les plasmas. En pratique, il est necessaire d'utiliser plusieurs methodes simultanement. (auteur)

  10. Protease-activated receptor (PAR2, but not PAR1, is involved in collateral formation and anti-inflammatory monocyte polarization in a mouse hind limb ischemia model.

    Directory of Open Access Journals (Sweden)

    Lisa G van den Hengel

    Full Text Available AIMS: In collateral development (i.e. arteriogenesis, mononuclear cells are important and exist as a heterogeneous population consisting of pro-inflammatory and anti-inflammatory/repair-associated cells. Protease-activated receptor (PAR1 and PAR2 are G-protein-coupled receptors that are both expressed by mononuclear cells and are involved in pro-inflammatory reactions, while PAR2 also plays a role in repair-associated responses. Here, we investigated the physiological role of PAR1 and PAR2 in arteriogenesis in a murine hind limb ischemia model. METHODS AND RESULTS: PAR1-deficient (PAR1-/-, PAR2-deficient (PAR2-/- and wild-type (WT mice underwent femoral artery ligation. Laser Doppler measurements revealed reduced post-ischemic blood flow recovery in PAR2-/- hind limbs when compared to WT, while PAR1-/- mice were not affected. Upon ischemia, reduced numbers of smooth muscle actin (SMA-positive collaterals and CD31-positive capillaries were found in PAR2-/- mice when compared to WT mice, whereas these parameters in PAR1-/- mice did not differ from WT mice. The pool of circulating repair-associated (Ly6C-low monocytes and the number of repair-associated (CD206-positive macrophages surrounding collaterals in the hind limbs were increased in WT and PAR1-/- mice, but unaffected in PAR2-/- mice. The number of repair-associated macrophages in PAR2-/- hind limbs correlated with CD11b- and CD115-expression on the circulating monocytes in these animals, suggesting that monocyte extravasation and M-CSF-dependent differentiation into repair-associated cells are hampered. CONCLUSION: PAR2, but not PAR1, is involved in arteriogenesis and promotes the repair-associated response in ischemic tissues. Therefore, PAR2 potentially forms a new pro-arteriogenic target in coronary artery disease (CAD patients.

  11. Apoplejía pituitaria con parálisis del III par craneal: Reporte de caso

    Directory of Open Access Journals (Sweden)

    Miguel Pinto Valdivia

    2011-10-01

    Full Text Available Se describe el caso de un varón de 65 años de edad, sin antecedentes patológicos de importancia, que acudió a emergencia del Hospital Nacional Cayetano Heredia por presentar cefalea intensa y ptosis palpebral izquierda. El examen físico mostró parálisis aislada del III par craneal izquierdo. Los análisis de laboratorio mostraron hiponatremia e hipopituitarismo y la resonancia magnética nuclear un adenoma pituitario con áreas de hemorragia e invasión de los senos cavernosos. El tratamiento incluyó glucocorticoides y descompresión quirúrgica transesfenoidal. La anatomía patológica confirmó el diagnóstico de infarto hemorrágico de un adenoma pituitario. El paciente fue dado de alta con terapia sustitutiva de levotiroxina y prednisona. La ptosis palpebral izquierda se recuperó en forma parcial. La apoplejía pituitaria es un síndrome clínico producido por un proceso expansivo dentro de la silla turca, secundario a hemorragia o infarto de un adenoma pituitario, que se caracteriza por cefalea, déficit visual, oftalmoplejía y alteración del nivel de conciencia. Este proceso expansivo puede comprimir los pares craneales en los senos cavernosos, produciendo diferentes grados de parálisis de los músculos oculomotores. La parálisis aislada del III par craneal es rara.(Rev Med Hered 2011;22:186-189.

  12. Copenhagen uPAR prostate cancer (CuPCa) database

    DEFF Research Database (Denmark)

    Lippert, Solvej; Berg, Kasper D; Høyer-Hansen, Gunilla

    2016-01-01

    AIM: Urokinase plasminogen activator receptor (uPAR) plays a central role during cancer invasion by facilitating pericellular proteolysis. We initiated the prospective 'Copenhagen uPAR Prostate Cancer' study to investigate the significance of uPAR levels in prostate cancer (PCa) patients. METHODS...

  13. Industrial uses of radioelements in France; Utilisation industrielle des radioelements en France

    Energy Technology Data Exchange (ETDEWEB)

    Gueron, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The birth of a nuclear industry has permitted the use of radioelements in an increasing number of domains. Currently, the majority of radioelements applications in industrial problematic are essentially on nondestructive control and on problems of static electricity, as well as in a least way for the use of the intense radiation sources, on agronomic problems, for hydrology or chemical analyses. In order to promote the industrial applications, The CEA took to this purpose several sets of decisions: 1 - institution of teachings and collaboration; 2 - encourage the constructors of devices; 3 - creation of a help service to the users. (M.B.) [French] La naissance d'une industrie nucleaire a permit l'emploi des radioelements dans un nombre croissant de domaines. Actuellement, la majorite des applications industrielles de radioelements porte essentielement sur le controle non destructif et les problemes d'electricite statique, ainsi que dans une moindre mesure l'utilisation des rayonnements intenses, les problemes agronomiques, les questions d'hydrologie, les analyses chimiques. Afin de promouvoir les applications industrielles, Le Commissariat a l'Energie Atomique a pris a cet effet plusieurs series de mesures: 1- institution d'enseignements et de collaboration; 2- encouragement aux constructeurs d'appareils; 3- creation d'un service de consultation aux usagers. (M.B.)

  14. Recombination in the human Pseudoautosomal region PAR1.

    Directory of Open Access Journals (Sweden)

    Anjali G Hinch

    2014-07-01

    Full Text Available The pseudoautosomal region (PAR is a short region of homology between the mammalian X and Y chromosomes, which has undergone rapid evolution. A crossover in the PAR is essential for the proper disjunction of X and Y chromosomes in male meiosis, and PAR deletion results in male sterility. This leads the human PAR with the obligatory crossover, PAR1, to having an exceptionally high male crossover rate, which is 17-fold higher than the genome-wide average. However, the mechanism by which this obligatory crossover occurs remains unknown, as does the fine-scale positioning of crossovers across this region. Recent research in mice has suggested that crossovers in PAR may be mediated independently of the protein PRDM9, which localises virtually all crossovers in the autosomes. To investigate recombination in this region, we construct the most fine-scale genetic map containing directly observed crossovers to date using African-American pedigrees. We leverage recombination rates inferred from the breakdown of linkage disequilibrium in human populations and investigate the signatures of DNA evolution due to recombination. Further, we identify direct PRDM9 binding sites using ChIP-seq in human cells. Using these independent lines of evidence, we show that, in contrast with mouse, PRDM9 does localise peaks of recombination in the human PAR1. We find that recombination is a far more rapid and intense driver of sequence evolution in PAR1 than it is on the autosomes. We also show that PAR1 hotspot activities differ significantly among human populations. Finally, we find evidence that PAR1 hotspot positions have changed between human and chimpanzee, with no evidence of sharing among the hottest hotspots. We anticipate that the genetic maps built and validated in this work will aid research on this vital and fascinating region of the genome.

  15. Modèle de régression optimale des traits de conformation et de la ...

    African Journals Online (AJOL)

    SARAH

    31 mai 2017 ... control.It was found that daily milk production was positively ... éleveurs, ni à leurs méthodes de gestion des ... performances laitières par l'analyse des corrélations, ... Les méthodes de mesure biométrique : En station,.

  16. Le temps mesurable, réversible, insaisissable ?

    CERN Document Server

    Fink, Martin; Leduc , Michèle

    2016-01-01

    Depuis l'Antiquité, la nature du temps a fasciné nombre de grands penseurs. Cet ouvrage expose ce que la physique est capable de dire aujourd'hui sur le sujet. La mesure du temps, ou plus exactement celle d'une durée, se fait grâce à des horloges atomiques dont l'exactitude peut atteindre une seconde sur plusieurs milliards d'années. Nous décrivons la façon dont s'effectue le transfert du temps qui permet la synchronisation d'horloges en différents points de la Terre ou de l'espace au milliardième de seconde près, ou même mieux. Les relativités, restreinte et générale, ont bouleversé notre conception du temps et ont un impact considérable sur certains problèmes de la vie quotidienne comme l'utilisation du GPS. On abandonne l'idée d'un temps absolu, le temps devient multiple et insaisissable, et peut-être même une illusion. Enfin la flèche du temps, ou l'irréversibilité, implique que les phénomènes physiques se déroulent toujours dans un sens déterminé, en relation avec la croissan...

  17. A modification of the method for determining current efficiency of aluminium electrolytic cells; Modification de la methode permettant de determiner le rendement des cuves dans la production d'aluminium par electrolyse; Izmenenie metoda opredeleniya ehffektivnosti toka v alyuminievykh ehlektroliticheskikh bakakh; Modificacion del metodo para determinar el rendimiento de las celdas utilizadas en la produccion de aluminio por electrolisis

    Energy Technology Data Exchange (ETDEWEB)

    Pradzynski, A [Institute of Basic Technical Problems, Polish Academy of Sciences. Warsaw (Poland); Orman, Z [Institute of Nonferrous Metals, Gliwice (Poland)

    1962-01-15

    The method for determining the current efficiency of aluminium electrolytic cells described first by REMPEL et al. was improved by BOZOKY et al. by using the radioisotope Au{sup 198}. In that work, master alloys of aluminium with Au{sup 198} were made, and samples of this were measured by means of a G-M tube with a lead absorber inserted between the tube and the sample. In this work the specific activity of the master alloy was reduced by diluting with a known quantity of pure aluminium. In that way samples of diluted master alloy and samples taken from the electrolytic cell were of the same order of specific activity and could be measured without any absorber. Radioactivation analysis was employed in order to facilitate the application of the above method in aluminium plants and to avoid all restrictions and dangers connected with the handling of unsealed radioactive sources outside special radioisotope laboratories. Inactive gold was introduced into the master alloy and into the smelting bath in the electrolytic cell. The concentration of gold in samples of both the master alloy and the smelt was then measured after irradiating the samples in a nuclear reactor. (author) [French] La methode permettant de determiner le rendement des cuves a aluminium, exposee tout d'abord par Rempel et al., a ete perfectionnee par Bozoky et al. qui ont utilise a cet effet le radioisotope or-198. Des alliages types d'aluminium et d'or-198 ont ete prepares et des echantillons mesures au moyen d'un tube Geiger-Muller, un absorbeur en plomb etant insere entre le tube et l'echantillon. Les auteurs du memoire ont mesure l'activite specifique de l'alliage type apres dilution dans une quantite connue d'aluminium pur. Les echantillons d'alliage type ainsi dilue et les echantillons preleves dans la cuve electrolytique ayant alors une activite specifique du meme ordre, il a ete possible de la mesurer sans aucun absorbeur. Les auteurs ont procede a des essais d'analyse par radioactivation afin

  18. Some examples of the utilization of autoradiography in metallurgy; Quelques exemples de l'utilisation de l'autoradiographie en metallurgie

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Although autoradiography has been used for a long time for metallurgic studies, new possibilities are open by a full exploitation of recent progress in nuclear emulsion techniques. A few examples are presented. (author) [French] Bien que l'autoradiographie soit connue de longue date comme une methode d'etude de certains problemes metallurgiques, de nouvelles possibilites sont offertes par l'utilisation d'emulsions nucleaires et l'exploitation systematique de toutes leurs proprietes. Quelques exemples sont presentes. (auteur)

  19. Plasma suPAR is lowered by smoking cessation

    DEFF Research Database (Denmark)

    Eugen-Olsen, Jesper; Ladelund, Steen; Sørensen, Lars Tue

    2016-01-01

    BACKGROUND: Soluble urokinase plasminogen activator receptor (suPAR) is a stable inflammatory biomarker. In patients, suPAR is a marker of disease presence, severity and prognosis. In the general population, suPAR is predictive of disease development, such as diabetes and cardiovascular disease a...

  20. Characteristics of membranes which are suitable for isotopic separation by gaseous diffusion; Caracteristiques des barrieres utilisables pour la separation isotopique par diffusion gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Massignon, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    rayon de pore r{sub wicke} effectif en regime intermediaire, le rayon de pore r{sub sep.} effectif en separation et les repartitions de rayons de pore definies par la porosimetrie au mercure, le B.E.T. et la diffusion centrale des rayons X. Nous donnerons d'abord la definition adoptee en pratique pour ces grandeurs empiriques, adaptees a un controle rapide des qualites des barrieres, en les reliant aux proprietes caracteristiques de quelques modeles de structure poreuse. Dans une seconde partie, nous montrerons sur quelques exemples empruntes aux mesures de routine, comment elles permettent, par recoupement, d'ecarter les barrieres a structure defavorable. (auteur)

  1. Neutron distribution in the central cell and a peripheral cell of the Fontenay-aux-Roses pile; Repartition des neutrons dans la cellule centrale et une cellule peripherique de la pile de Fontenay-aux-Roses

    Energy Technology Data Exchange (ETDEWEB)

    Roullier, F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1958-07-01

    The distribution of the neutron density has been determined in the central cell and a peripheral cell of the pile at Fontenay-aux-Roses. This measurement was carried out by the autoradiographic method with manganese detectors. The neutron density distribution in the uranium rod has already been studied. The measurement was completed by the study of the neutron density in the complete cell by means of detectors placed in the uranium and in the heavy water. (author) [French] La repartition de la densite des neutrons a ete determinee dans la cellule centrale et une cellule peripherique de la pile de Fontenay-aux-Roses. Cette mesure a ete effectuee par la methode d'autoradiographie avec des detecteurs de manganese. La repartition de la densite des neutrons dans la barre d'uranium a deja ete etudiee. La mesure a ete completee par l'etude de la densite des neutrons dans la cellule complete a l'aide de detecteurs places dans l'uranium et dans l'eau lourde. (auteur)

  2. Vers une économie politique des conflits

    African Journals Online (AJOL)

    mettant en œuvre des «ruses et tactiques» (De Certeau l990:65). Cette démarche .... regard peut être à l'origine du conflit dans la mesure où il est interprété ... préparée par sa femme constitue un acte de rejet qui d'emblée crée une situation de ... sur la crise de ce système au moment où, confrontées au risque du sida,.

  3. Effect of cobalt-60 {gamma} radiation and of thermal neutrons on high resistance P and N silicon. Possibility of obtaining a nuclear compensation for P type silicon; Effects du rayonnement {gamma} du cobalt 60 et de neutrons thermiques sur du silicium P et N de haute resistivite. Possibilite de realiser une compensation nucleaire d'un silicium du type P

    Energy Technology Data Exchange (ETDEWEB)

    Messier, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-11-01

    Type P silicon has been compensated by the production of a controlled and uniform amount of donor atoms ({sup 31}P) using thermal neutrons to bring about a nuclear transformation. It is shown that it is possible in this way to reduce by a factor of about one hundred the overall concentration of residual ionised impurities in the purest crystals obtained by floating zone purification (2 x 10{sup 12} atoms/cm{sup 3}). The degree compensation obtained is limited by the initial inhomogeneity of acceptor impurities which have to be compensated. Lattice defects which still remain after prolonged annealings reduce the life-time of the material to about 10 {mu}s approximately. Particle detectors having thicknesses of 2 to 5 mm have been built by this process; they give good results, particularly at low temperatures. A study has also been made of the number and of the nature of lattice defects produced by thermal neutrons in high resistivity P and N type crystals. These defects have been compared to those produced by {gamma} rays from {sup 60}Co. A discussion is given of the validity of the Wertheim model concerning pronounced recombination at low temperatures (77 deg. K - 300 deg. K) of primary defect-interstitial pairs. The nature of the defects introducing energy levels into the lower half of the forbidden band has been studied. (author) [French] On a compense du silicium de type P en produisant, au moyen de neutrons thermiques, par transmutation nucleaire une quantite controlee et uniforme d'atomes donneurs ({sup 31}P). On montre qu'on peut ainsi reduire de cent fois environ la densite nette d'impuretes ionisees residuelles subsistant dans les cristaux les plus purs obtenus par purification par zone flottante (2.10{sup 12} atomes/cm{sup 3}). Le degre de compensation obtenu est limite par i'inhomogeneite initiale des impuretes acceptrices a compenser. Des defauts de reseau qui subsistent meme apres des recuits prolonges reduisent la duree de vie du materiau a 10 {mu

  4. Evaluation technique des analyseurs de mesure de la qualité de l'air

    OpenAIRE

    Tatry , Véronique

    1996-01-01

    Les objectifs des évaluations techniques des analyseurs de mesure de la qualité de l'air sont : de vérifier les performances métrologiques de ces analyseurs, de connaître la capacité des appareils à travailler sur le terrain, d'évaluer la capacité du fournisseur à résoudre les problèmes techniques que pose l'exploitation de son appareil. Cette activité existe à l'INERIS depuis plus de 20 ans (ex CERCHAR et ex IRCHA). Elle s'appuie sur une procédure décrite dans la norme française NF X 20-300 ...

  5. Application of resistivity measurements to the control of protein elutions using cellulose ion-exchangers; Application de la mesure de resistivite au controle d'une elution de proteines a partir de celluloses echangeuses d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Duplaa, A M; Brandolin, G [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    The eluate obtained by chromatography of a mixture of proteins on columns of cellulose ion-exchangers (DEAE-cellulose and CM-cellulose) sometimes have very low proteins concentrations. The resistivity measurement gives more information than the UV control which is often inadequate. The modifications undergone by elution buffers are recorded and the best conditions for the extraction of an enzymatic protein are determined. The tests are performed without proteins on the columns; they consist in a double control of resistivity and ph of elution buffers after they pass on the exchangers columns. (author) [French] Apres chromatographie d'un melange de proteine; sur colonnes d'echangeurs d'ions tels que DEAE-cellulose et CM-cellulose, les eluats obtenus ont quelquefois des concentrations en proteines tres faibles. Au controle en UV souvent insuffisant, on a ajoute la mesure de resistivite apportant des donnees complementaires. Des essais, realises en l'absence de proteines et consistant a effectuer un double controle de resistivite et de pH des tampons d'elution apres leur passage sur colonnes d'echangeurs, ont permis d'enregistrer les modifications subies par ces tampons et de determiner leurs meilleures conditions d'utilisation pour l'extraction d'une proteine enzymatique. (auteur)

  6. Measurement of the temperature of the neutrons in reactor G1; Mesure de la temperature des neutrons dans la pile G1

    Energy Technology Data Exchange (ETDEWEB)

    Raievski, V; Sautiez, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    A precise experimental method has been adapted to the analysis of the spectrum of neutrons in the thermal region. This method uses the technique of modulation applied to a beam of neutrons issuing from a characteristic point in the pile. The analysis of the spectrum is made by adjusting, by the method of least squares, an analytical form to the experimental results. In this report are given the results obtained with a beam from the centre of the moderator of G1. The spectrum of this beam essentially represents the spectrum of the neutrons in the moderator. The most probable velocity was determined by means of Maxwell's functions. The measurements were made of different moderator temperatures between 304 deg. K and 435 deg. K. (author) [French] Une methode experimentale precise a ete mise au point pour l'analyse du spectre des neutrons dans le domaine thermique. Cette methode utilise la technique de la modulation appliquee a un faisceau de neutrons issu d'un point caracteristique de la pile. L'analyse du spectre est faite en ajustant par la methode des moindres carres une forme analytique aux resultats experimentaux. Dans ce rapport, on donne les resultats obtenus sur un faisceau du centre du moderateur de G1. Le spectre de ce faisceau represente convenablement le spectre des neutrons dans le moderateur. On s'est limite ici a une fonction de Maxwell dont on a recherche la vitesse la plus probable. Les mesures ont ete faites avec une temperature du moderateur variant entre 304 deg. K et 435 deg. K. (auteur)

  7. ÉTUDE DE CAS — Une puissance de calcul | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    13 janv. 2011 ... Ils sont ainsi en mesure de planifier et de budgétiser la prestation des .... L'outil « profil de la charge de morbidité » élaboré par le PIEST aide à la ... L'utilisation du SSD comme instrument de politique est aussi rentable.

  8. 1327-IJBCS-Article-Paul Gnangle

    African Journals Online (AJOL)

    KODJIO NORBERT

    Perceptions locales du changement climatique et mesures d'adaptation dans la ... densité de pieds de karité dans le terroir du village, de l'importance représentée par le ... l'enlèvement de gui sur le karité, l'adaptation de nouvelles cultures en.

  9. Compter les toits – Quand des techniques de télédétection ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    7 janv. 2013 ... Pour mesurer les répercussions de la croissance rapide des bidonvilles ... Société canadienne d'hypothèques et de logement a travaillé avec DW Angola ... c'est-à-dire reportées sur la surface de la Terre, par divers moyens.

  10. institutions pour la gestion efficace de la demande en eau

    International Development Research Centre (IDRC) Digital Library (Canada)

    nkhaled

    1 On entend par la gestion de la demande en eau (GDE) « toute mesure ...... Mis à part un faible pourcentage réservé à l'abreuvement du bétail et au traitement de base des ..... demand management », Physics and Chemistry of the Earth, vol.

  11. Évaluation de la courbe de rétention d'eau de l'aquifère du ...

    African Journals Online (AJOL)

    SARAH

    29 mai 2013 ... sont mal connues pour définir un plan de gestion. Dans les .... Mesure de la teneur en eau du sol : Quatre puits ont ... d'adhésion et contrôle la saturation par adhésion. Selon .... performance of cover with double capillary.

  12. Katanga, RD Congo

    African Journals Online (AJOL)

    SARAH

    31 mai 2014 ... 2Section Gestion de l'eau et fertilité du sol, Antenne Gestion des ... mesure par sa capacité à produire de manière ... Le maintien de cette performance est vital tandis .... de l'office Congolais de Contrôle (OCC) en vue de.

  13. The inflammatory marker suPAR after cardiac arrest

    DEFF Research Database (Denmark)

    Rundgren, Malin; Lyngbaek, Stig; Fisker, Helle

    2015-01-01

    . This pilot study aimed at investigating suPAR levels in relation to outcome after CA and mild induced hypothermia. METHODS: suPAR levels were measured at 6, 36, and 72 hours in patients treated with hypothermia after CA. suPAR levels were analyzed in relation to survival after 6 months. Receiver operating...

  14. Physical measurements in Marcoule reactors (1962); Mesures physiques sur les reacteurs de Marcoule (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Teste du Bailler, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    A brief description of the physical measurements in Marcoule reactors is given here. During commissioning and subsequent years of operation, various experiments ha been carried out to check design data, and improve the operating conditions and also test theoretical models for kinetic studies. (author) [French] On presente une rapide description des mesures physiques effectuees sur les reacteurs de Marcoule. Au cours du demarrage et pendant les premieres annees de fonctionnement de G-2 - G-3, de nombreuses experiences ont ete effectuees pour verifier les donnees du projet, ameliorer les conditions de fonctionnement et eprouver des modeles theoriques de calculs de cinetique. (auteur)

  15. Heat transfer by gas-liquid mixture in forced turbulent flow with weak vaporization of the liquid phase (1962); Transfert de chaleur par melange de liquide et de gaz en convection forcee turbulente avec faible vaporisation de la phase liquide (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Huyghe, J; Mondin, G [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    The present study deals with measures of heat transfer and pressure drop in two-phase liquid flow. The stream is of annular dispersed type, obtained by introducing a small quantity of liquid in a gas turbulent flow. The heat transfer experiments are performed without vaporization of the liquid phase. A notable improvement of the heat transfer coefficient of such a stream is observed, compared with a gas-alone or liquid-alone flow. The improvement concerning the gas-alone is of about 20 when it is compared with the same gas Reynolds's number, of about 8 when it is compared with the same total mass flow rate. A hydrodynamic study of the flow pattern lets us know the original structure of the flow, and allows to foresee the experimental results by means of a simplified theory. (authors) [French] II est fait etat de mesures de transfert thermique et de perte de charge dans un ecoulement en double phase gaz-liquide. L'ecoulement est du type annulaire disperse, obtenu par injection d'une faible quantite de liquide dans un ecoulement gazeux en regime turbulent. Les experiences de transfert thermique sont menees sans vaporisation de la phase liquide. On note une amelioration sensible du coefficient de transfert thermique dans un tel ecoulement par rapport a un ecoulement de gaz seul ou de liquide seul. L'augmentation est de l'ordre de 20 par rapport au gaz seul si on opere a meme nombre de REYNOLDS du gaz, de l'ordre de 8 si on opere a meme debit massique total. Une etude hydrodynamique rapide de l'ecoulement permet de connaitre la structure originale de l'ecoulement, puis de prevoir par une theorie simplifiee le phenomene thermique observe. (auteurs)

  16. Radioactive apparatus for measuring the thickness of hot sheet-metal; Jauge d'epaisseur radioactive pour la mesure a chaud de plaques metalliques; Radioaktivnyj izmeritel' tolshchiny goryachego listovogo prokata; Calibrador radiactivo para la medicion en caliente de chapas

    Energy Technology Data Exchange (ETDEWEB)

    Vasichev, B N; Latyshev, V K; Pliskin, Yu S; Felinger, A K

    1962-01-15

    In order to achieve a high precision of measurement under rolling conditions, a dynamic method of compensation was chosen, by which the comparison parameter moves through all the values in the range of measurement, whereas the zero component designates only the moment when the measured parameter and the comparison parameter are equal. This method eliminates the mechanical return communications and variable displacements of the static-compensation method, and gives an instrument which is both sufficiently accurate and operates with sufficient speed in the complicated process of rolling. The basic design of the instrument, for checking the thickness of the sheet during the rolling process is described and the factors affecting the accuracy of measurement of a sheet (temperature, undulation, superficial moisture, composition of the sheet, and its position on the roller train) are discussed. The construction of an experimental instrument for industrial use over a thickness range of 14-44 mm is also described. The industrial tests carried out with the instrument showed that, with a Cs{sup 137} source of activity equivalent to 9.2 g radium, the accuracy of measurement of the thickness of hot sheet within the specified range is {+-}0.1 mm. The instrument's operating speed is one measurement per second. It works reliably under the conditions of the rolling mill. (author) [French] Pour obtenir une grande precision dans les mesures en cours de laminage, les auteurs ont choisi la methode dynamique de compensation, dans laquelle le parametre de comparaison passe par toutes les valeurs de la gamme de mesures, la composante zero designant uniquement le moment ou le parametre mesure et le parametre de comparaison sont egaux. Cette methode permet d'eliminer les systemes mecaniques de retour et les deplacements variables qui caracterisent la methode statique de compensation, et d'avoir un appareil a la fois suffisamment precis et d'un fonctionnement suffisamment rapide. Les auteurs

  17. It's quicker "Par Avignon"!

    CERN Multimedia

    2005-01-01

    For a few years, the CERN Library has been receiving books from the University of Hanover sent via Avignon, at least that's what it says on the envelope. Such a detour would mean that parcels were travelling 720 km more than the distance separating Geneva and Hanover, which would be a very strange state of affairs. The explanation lies in a spelling mistake. The sender has been stamping parcels with a stamp that says "Par Avignon prioritaire" (first-class via Avignon) instead of "Par Avion prioritaire" (First Class Air Mail), a source of much amusement to the librarians!

  18. Serum suPAR in patients with FSGS: trash or treasure?

    Science.gov (United States)

    Maas, Rutger J H; Deegens, Jeroen K J; Wetzels, Jack F M

    2013-07-01

    The urokinase-type plasminogen activator receptor (uPAR) has important functions in cell migration. uPAR can be shed from the cell membrane resulting in soluble uPAR (suPAR). Further cleavage gives rise to shorter fragments with largely unknown functions. Recent studies have demonstrated that both overexpression of uPAR on podocytes and the administration of suPAR cause proteinuria in mice. The common pathogenic mechanism involves the activation of podocyte β3-integrin. Increased activation of β3-integrin is also observed in patients with focal and segmental glomerulosclerosis (FSGS). These observations form the basis for the hypothesis that suPAR may be the circulating factor causing FSGS. A recent study fosters this idea by demonstrating increased suPAR levels in the serum of patients with FSGS and reporting an association with recurrence after transplantation and response to plasmapheresis. However, this study was heavily biased, and subsequent studies have given conflicting results. Although the experimental work is very suggestive, at present there is no proof that any known human suPAR fragment causes FSGS in humans. We therefore suggest that the measurement of suPAR using currently available assays has absolutely no value at the present time in decision-making in routine clinical practice.

  19. Proteinase-Activated Receptor 1 (PAR1 regulates leukemic stem cell functions.

    Directory of Open Access Journals (Sweden)

    Nicole Bäumer

    Full Text Available External signals that are mediated by specific receptors determine stem cell fate. The thrombin receptor PAR1 plays an important role in haemostasis, thrombosis and vascular biology, but also in tumor biology and angiogenesis. Its expression and function in hematopoietic stem cells is largely unknown. Here, we analyzed expression and function of PAR1 in primary hematopoietic cells and their leukemic counterparts. AML patients' blast cells expressed much lower levels of PAR1 mRNA and protein than CD34+ progenitor cells. Constitutive Par1-deficiency in adult mice did not affect engraftment or stem cell potential of hematopoietic cells. To model an AML with Par1-deficiency, we retrovirally introduced the oncogene MLL-AF9 in wild type and Par1-/- hematopoietic progenitor cells. Par1-deficiency did not alter initial leukemia development. However, the loss of Par1 enhanced leukemic stem cell function in vitro and in vivo. Re-expression of PAR1 in Par1-/- leukemic stem cells delayed leukemogenesis in vivo. These data indicate that Par1 contributes to leukemic stem cell maintenance.

  20. Proteinase-Activated Receptor 1 (PAR1) regulates leukemic stem cell functions.

    Science.gov (United States)

    Bäumer, Nicole; Krause, Annika; Köhler, Gabriele; Lettermann, Stephanie; Evers, Georg; Hascher, Antje; Bäumer, Sebastian; Berdel, Wolfgang E; Müller-Tidow, Carsten; Tickenbrock, Lara

    2014-01-01

    External signals that are mediated by specific receptors determine stem cell fate. The thrombin receptor PAR1 plays an important role in haemostasis, thrombosis and vascular biology, but also in tumor biology and angiogenesis. Its expression and function in hematopoietic stem cells is largely unknown. Here, we analyzed expression and function of PAR1 in primary hematopoietic cells and their leukemic counterparts. AML patients' blast cells expressed much lower levels of PAR1 mRNA and protein than CD34+ progenitor cells. Constitutive Par1-deficiency in adult mice did not affect engraftment or stem cell potential of hematopoietic cells. To model an AML with Par1-deficiency, we retrovirally introduced the oncogene MLL-AF9 in wild type and Par1-/- hematopoietic progenitor cells. Par1-deficiency did not alter initial leukemia development. However, the loss of Par1 enhanced leukemic stem cell function in vitro and in vivo. Re-expression of PAR1 in Par1-/- leukemic stem cells delayed leukemogenesis in vivo. These data indicate that Par1 contributes to leukemic stem cell maintenance.