WorldWideScience

Sample records for normal ap laxity

  1. Dynamic knee alignment and collateral knee laxity and its variations in normal humans

    Directory of Open Access Journals (Sweden)

    Kamal eDeep

    2015-11-01

    Full Text Available Alignment of normal, arthritic and replaced human knees is a much debated subject as is the collateral ligamentous laxity. Traditional quantitative values have been challenged. Methods used to measure these are also not without flaws. Authors review the recent literature and a novel method of measurement of these values has been included. This method includes use of computer navigation technique in clinic setting for assessment of the normal or affected knee before the surgery. Computer navigation has been known for achievement of alignment accuracy during knee surgery. Now its use in clinic setting has added to the inventory of measurement methods. Authors dispel the common myth of straight mechanical axis in normal knees and also look at quantification of amount of collateral knee laxity. Based on the scientific studies it has been shown that the mean alignment is in varus in normal knees. It changes from lying non weight bearing position to standing weight bearing position in both coronal and the sagittal planes. It also varies with gender and race. The collateral laxity is also different for males and females. Further studies are needed to define the ideal alignment and collateral laxity which the surgeon should aim for individual knees.

  2. The Relationship Between Early-Stage Knee Osteoarthritis and Lower-Extremity Alignment, Joint Laxity, and Subjective Scores of Pain, Stiffness, and Function.

    Science.gov (United States)

    Hicks-Little, Charlie A; Peindl, Richard D; Hubbard-Turner, Tricia J; Cordova, Mitchell L

    2016-08-01

    Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. Case control. Sports-medicine research laboratory. 18 participants with knee OA and 18 healthy matched controls. Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). WOMAC scores, A-P (mm), and ALIGN (°). A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P Knee-OA participants differed in WOMAC scores (P knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.

  3. Joint Laxity in Preschool Children Born Preterm.

    Science.gov (United States)

    Romeo, Domenico M; Velli, Chiara; Lucibello, Simona; Ferrantini, Gloria; Leo, Giuseppina; Brogna, Claudia; Cota, Francesco; Ricci, Daniela; Gallini, Francesca; Romagnoli, Costantino; Vento, Giovanni; Mercuri, Eugenio

    2018-06-01

    To evaluate the prevalence of joint laxity in children born preterm assessed in the first 2 years, the relationship between joint laxity and motor performance at preschool age, and possible changes over time in a subgroup of children followed longitudinally. The revised scale of Beighton Score was used to evaluate joint laxity in a population of 132 preschool children born preterm between 24 and 32 weeks of gestational age. All were assessed for joint laxity between 12 and 24 months of age. Children also performed the Movement Assessment Battery for Children-Second Edition between the age of 3 years and 6 months and 4 years; the age at onset of independent walking also was recorded. The total Beighton Score ranged between 0 and 8. Twenty percent of the cohort showed joint laxity. No differences related to sex or gestational age were observed. Children born preterm with joint laxity achieved later independent walking and achieved lower scores on Movement Assessment Battery for Children-Second Edition than those without joint laxity. In 76 children born preterm, an assessment for joint laxity was repeated once between 25 and 36 months and again after >36 months. No statistically significant difference was observed between the 3 assessments. The Beighton Score can be used to assess generalized joint laxity in children born preterm. As the presence of joint laxity influenced motor competences, the possibility to early identify these infants in the first 2 years is of interest to benefit from early intervention and potentially improve gross motor skills and coordination. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture

    DEFF Research Database (Denmark)

    Jensen, Steen Lund; Olsen, Bo Sanderhoff; Tyrdal, Stein

    2005-01-01

    The objectives of this experimental study were to investigate the effect of radial head excision and lateral collateral ligament (LCL) division on elbow joint laxity and to determine the efficacy of radial head prosthetic replacement and LCL repair. Valgus, varus, internal rotation, and external...... rotation of the ulna were measured during passive flexion-extension and application of a 0.75-Nm torque in 6 intact cadaveric elbows and after (1) either excision of the radial head or division of the LCL, (2) removal of both constraints, (3) isolated radial head prosthetic replacement, (4) isolated LCL...... normalized varus laxity but resulted in a 2.9 degrees increase in external rotatory laxity. The combined procedures restored laxity completely. The radial head is a constraint to varus and external rotation in the elbow joint, functioning by maintaining tension in the LCL. Still, removal of both constraints...

  5. Collateral ligament strains during knee joint laxity evaluation before and after TKA.

    Science.gov (United States)

    Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan

    2013-08-01

    Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Loss-of-normal-feedwater sensitivity studies for AP600 behavior characterization

    International Nuclear Information System (INIS)

    Saiu, G.

    1996-01-01

    Activity concerning the development of a RELAP5/MOD3 model to simulate the Westinghouse Electric Corporation AP600 is summarized. The aim is to gain initial insight into the capability of RELAP5 to simulate the behavior of AP600 safety features. A-loss-of-normal-feedwater event is studied. Of the transients that must be investigated, this transient has been chosen to be one of the most relevant because the response of the AP600 to a loss-of-normal-feedwater event differs significantly from that of current pressurized water reactors in the extensive use of passive safety features peculiar to the AP600. Also, strong interactions among the AP600 safety systems, which should be further analyzed to permit full optimization of the system actuation logic and operation, are shown. Finally, a loss of normal feedwater without reactor scram, performed to investigate short-term plant behavior, shows that the pressure peak is affected by critical discharge flow coefficients applied to the pressurizer safety valves, while a relatively small reduction of the pressure peak is observed when both heat exchangers of the passive heat removal system are operating as opposed to the case in which only one is available. The data used for this study are derived from the Standard Safety Analysis Report configuration of the Westinghouse AP600 as of 1992

  7. Associations between lower extremity muscle mass and multiplanar knee laxity and stiffness: a potential explanation for sex differences in frontal and transverse plane knee laxity.

    Science.gov (United States)

    Shultz, Sandra J; Pye, Michele L; Montgomery, Melissa M; Schmitz, Randy J

    2012-12-01

    Compared with men, women have disproportionally greater frontal (varus-valgus) and transverse (internal-external) plane laxity and lower stiffness, despite having similar sagittal (anterior-posterior) plane laxity and stiffness. While the underlying cause is unclear, the amount of lower extremity lean mass (LELM) may be a contributing factor. Lower extremity lean mass would be a stronger predictor of frontal and transverse plane laxity and incremental stiffness than the sagittal plane. Associations between LELM and stiffness would be stronger at lower force increments. Descriptive laboratory study. Sixty-three women and 30 men with no history of ligament injury were measured for knee laxity and incremental stiffness in the sagittal (-90- to 130-N posterior-to-anterior directed loads), frontal (±10-N·m varus-valgus torques), and transverse (±5-N·m internal-external rotation torques) planes and underwent dual-energy X-ray absorptiometry scans to measure LELM. Linear regressions examined the extent to which LELM predicted each laxity and stiffness value, while also accounting for a person's sex. Females (vs males) had greater laxity and less stiffness in the frontal and transverse planes but not the sagittal plane. Lower extremity lean mass was a poor predictor of sagittal laxity and stiffness (R (2) range = .021-.081; P > .06) but was a stronger predictor of frontal (R (2) range = .215-.567; P plane laxity and stiffness. Associations were stronger for low (R (2) = .495-.504) versus high (R (2) = .215-.435) frontal plane stiffness but were similar for low (R (2) = .233-.293) versus high (R (2) = .224-.356) transverse plane stiffness. Once we accounted for a person's LELM, sex had little effect on laxity and stiffness (change in R (2) after removal = .01-.08; P = .027-.797). Less LELM was associated with greater laxity and less stiffness in frontal and transverse planes, which may contribute to the disproportionally higher laxities and reduced stiffnesses observed

  8. Relationship between degenerative joint disease and hip joint laxity by use of distraction index and Norberg angle measurement in a group of cats

    International Nuclear Information System (INIS)

    Langenbach, A.; Giger, U.; Green, P.; Rhodes, H.; Gregor, T.P.; Lafond, E.; Smith, G.

    1998-01-01

    Objective: To determine the relationship between degenerative joint disease (DJD) and passive laxity of the hip joint in a group of cats. Design: Prospective study. Animals: A select (nonrandomized) group of 78 cats. Procedure: Standard hip-extended radiographic views and compression and distraction views of the pelvis were obtained from cats during sedation. Radiographs were evaluated, using an Orthopedic Foundation for Animals (OFA)-like scoring system for dogs. Passive joint laxity was measured, using Norberg angle (NA) and distraction index (DI). Hip laxity in cats with DJD was compared with hip laxity in cats without DJD. Results: Hip dysplasia (HD) was subjectively diagnosed radiographically in 25 of 78 (32%) cats using the OFA-like scoring system. Nineteen cats had mild HD 4 had moderate HD, and 2 had severe HD. Fifteen of the 25 cats with HD had DJD. The NA ranged from 56 to 105. The mean NA in cats with DJD was (84 degrees) significantly lower than in cats without DJD (95 degrees). The DI ranged from 0.2 to 0.84. The mean DI for cats with DJD was (0.6) significantly higher than that for cats without DJD (0.49). Cats with a DI < 0.4 did not have DJD. Cats had an increased likelihood of having DJD with increased laxity in the coxofemoral joint, as measured by NA or DI. Clinical Implications: The mean NA for radiographically normal cats (92.4 degrees) was lower than that in radiographically normal dogs (103 degrees). The overall mean DI for cats in this group (0.51) is similar to dogs of breeds with high joint laxity, such as the Labrador Retriever (0.5). As in dogs, there is a relationship between DJD and laxity in the hip joint of cats

  9. Biomechanical Study about Lateral Ankle Laxity

    Directory of Open Access Journals (Sweden)

    Bogdan Voicu

    2009-12-01

    Full Text Available The objective of this paper is to study the contribution of the anterior talofibular ligament to ankle laxity at 18 cadaver ankles. For this, there was made an original, bipolar transoseus system, in a monitorized test stand Mx-500N Schmidt with a digital force gauge Imada. It was measured the motion response for applied antero-posterior force, inversion-eversion moment and internal-external rotary torque, in three positions of flexion of the ankle, with an intact anterior talofibular ligament and after it’s sectioning. The results showed a significant increases in laxity in plantar flexion for the inversion and internal rotary torque, this mechanism coresponding with common modes of injury.

  10. Study on radioactive release of gaseous and liquid effluents during normal operation of AP1000

    International Nuclear Information System (INIS)

    Gong Quan; Zhou Jing; Liu Yu

    2014-01-01

    The gaseous and liquid radioactive releases of pressurized water reactors plant during normal operation are an important content of environmental impact assessment and play a significant role in the design of nuclear power plant. According to the design characters of AP1OOO radioactive waste management system and the study on the calculation method and the release pathways, the calculation model of the gaseous and liquid radioactive releases during normal operation for AP1OOO are established. Base on the established calculation model and the design parameters of AP1000, the expected value of gaseous and liquid radioactive releases of AP1OOO is calculated. The results of calculation are compared with the limits in GB 6249-2011 and explain the adder that is included tu account for anticipated operational occurrences, providing a reference for environmental impact assessment of pressurized water reactor. (authors)

  11. Intertester reliability of clinical shoulder instability and laxity tests in subjects with and without self-reported shoulder problems.

    Science.gov (United States)

    Eshoj, Henrik; Ingwersen, Kim Gordon; Larsen, Camilla Marie; Kjaer, Birgitte Hougs; Juul-Kristensen, Birgit

    2018-03-03

    First, to investigate the intertester reliability of clinical shoulder instability and laxity tests, and second, to describe the mutual dependency of each test evaluated by each tester for identifying self-reported shoulder instability and laxity. A standardised protocol for conducting reliability studies was used to test the intertester reliability of the six clinical shoulder instability and laxity tests: apprehension, relocation, surprise, load-and-shift, sulcus sign and Gagey. Cohen's kappa (κ) with 95% CIs besides prevalence-adjusted and bias-adjusted kappa (PABAK), accounting for insufficient prevalence and bias, were computed to establish the intertester reliability and mutual dependency. Forty individuals (13 with self-reported shoulder instability and laxity-related shoulder problems and 27 normal shoulder individuals) aged 18-60 were included. Fair (relocation), moderate (load-and-shift, sulcus sign) and substantial (apprehension, surprise, Gagey) intertester reliability were observed across tests (κ 0.39-0.73; 95% CI 0.00 to 1.00). PABAK improved reliability across tests, resulting in substantial to almost perfect intertester reliability for the apprehension, surprise, load-and-shift and Gagey tests (κ 0.65-0.90). Mutual dependencies between each test and self-reported shoulder problem showed apprehension, relocation and surprise to be the most often used tests to characterise self-reported shoulder instability and laxity conditions. Four tests (apprehension, surprise, load-and-shift and Gagey) out of six were considered intertester reliable for clinical use, while relocation and sulcus sign tests need further standardisation before acceptable evidence. Furthermore, the validity of the tests for shoulder instability and laxity needs to be studied. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Changes in fatigue, multiplanar knee laxity, and landing biomechanics during intermittent exercise.

    Science.gov (United States)

    Shultz, Sandra J; Schmitz, Randy J; Cone, John R; Henson, Robert A; Montgomery, Melissa M; Pye, Michele L; Tritsch, Amanda J

    2015-05-01

    Knee laxity increases during exercise. However, no one, to our knowledge, has examined whether these increases contribute to higher-risk landing biomechanics during prolonged, fatiguing exercise. To examine associations between changes in fatigue (measured as sprint time [SPTIME]), multiplanar knee laxity (anterior-posterior [APLAX], varus-valgus [VVLAX] knee laxity, and internal-external rotation [IERLAX]) knee laxity and landing biomechanics during prolonged, intermittent exercise. Descriptive laboratory study. Laboratory and gymnasium. A total of 30 male (age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg) and 29 female (age = 20.5 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) competitive athletes. A 90-minute intermittent exercise protocol (IEP) designed to simulate the physiologic and biomechanical demands of a soccer match. We measured SPTIME, APLAX, and landing biomechanics before and after warm-up, every 15 minutes during the IEP, and every 15 minutes for 1 hour after the IEP. We measured VVLAX and IERLAX before and after the warm-up, at 45 and 90 minutes during the IEP, and at 30 minutes after the IEP. We used hierarchical linear modeling to examine associations between exercise-related changes in SPTIME and knee laxity with exercise-related changes in landing biomechanics while controlling for initial (before warm-up) knee laxity. We found that SPTIME had a more global effect on landing biomechanics in women than in men, resulting in a more upright landing and a reduction in landing forces and out-of-plane motions about the knee. As APLAX increased with exercise, women increased their knee internal-rotation motion (P = .02), and men increased their hip-flexion motion and energy-absorption (P = .006) and knee-extensor loads (P = .04). As VVLAX and IERLAX increased, women went through greater knee-valgus motion and dorsiflexion and absorbed more energy at the knee (P ≤ .05), whereas men were positioned in greater hip

  13. Structural joint changes, malalignment, and laxity in osteoarthritis of the knee

    NARCIS (Netherlands)

    van der Esch, M.; Steultjens, M.; Wieringa, H.; Dinant, H.; Dekker, J.

    2005-01-01

    To assess the relationship between (i) structural joint changes (i.e. joint space narrowing and osteophyte formation) and laxity and (ii) joint malalignment and laxity in osteoarthritis (OA) of the knee. A cross-sectional study was carried out on 35 outpatients with osteoarthritis of the knee.

  14. Knee joint laxity and passive stiffness in meniscectomized patients compared with healthy controls.

    Science.gov (United States)

    Thorlund, Jonas B; Creaby, Mark W; Wrigley, Tim V; Metcalf, Ben R; Bennell, Kim L

    2014-10-01

    Passive mechanical behavior of the knee in the frontal plane, measured as angular laxity and mechanical stiffness, may play an important role in the pathogenesis of knee osteoarthritis (OA). Little is known about knee laxity and stiffness prior to knee OA onset. We investigated knee joint angular laxity and passive stiffness in meniscectomized patients at high risk of knee OA compared with healthy controls. Sixty patients meniscectomized for a medial meniscal tear (52 men, 41.4 ± 5.5 years, 175.3 ± 7.9 cm, 83.6 ± 12.8 kg, mean ± SD) and 21 healthy controls (18 men, 42.0 ± 6.7 years, 176.8 ± 5.7 cm, 77.8 ± 13.4 kg) had their knee joint angular laxity and passive stiffness assessed twice ~2.3 years apart. Linear regression models including age, sex, height and body mass as covariates in the adjusted model were used to assess differences between groups. Greater knee joint varus (-10.1 vs. -7.3°, pknee joint angular laxity and reduced passive stiffness ~3 months post surgery compared with controls. In addition, the results indicated that knee joint laxity may increase over time in meniscectomized patients. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Incorporating ligament laxity in a finite element model for the upper cervical spine.

    Science.gov (United States)

    Lasswell, Timothy L; Cronin, Duane S; Medley, John B; Rasoulinejad, Parham

    2017-11-01

    Predicting physiological range of motion (ROM) using a finite element (FE) model of the upper cervical spine requires the incorporation of ligament laxity. The effect of ligament laxity can be observed only on a macro level of joint motion and is lost once ligaments have been dissected and preconditioned for experimental testing. As a result, although ligament laxity values are recognized to exist, specific values are not directly available in the literature for use in FE models. The purpose of the current study is to propose an optimization process that can be used to determine a set of ligament laxity values for upper cervical spine FE models. Furthermore, an FE model that includes ligament laxity is applied, and the resulting ROM values are compared with experimental data for physiological ROM, as well as experimental data for the increase in ROM when a Type II odontoid fracture is introduced. The upper cervical spine FE model was adapted from a 50th percentile male full-body model developed with the Global Human Body Models Consortium (GHBMC). FE modeling was performed in LS-DYNA and LS-OPT (Livermore Software Technology Group) was used for ligament laxity optimization. Ordinate-based curve matching was used to minimize the mean squared error (MSE) between computed load-rotation curves and experimental load-rotation curves under flexion, extension, and axial rotation with pure moment loads from 0 to 3.5 Nm. Lateral bending was excluded from the optimization because the upper cervical spine was considered to be primarily responsible for flexion, extension, and axial rotation. Based on recommendations from the literature, four varying inputs representing laxity in select ligaments were optimized to minimize the MSE. Funding was provided by the Natural Sciences and Engineering Research Council of Canada as well as GHMBC. The present study was funded by the Natural Sciences and Engineering Research Council of Canada to support the work of one graduate student

  16. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  17. Nonsurgical tightening of skin laxity: a new radiofrequency approach.

    Science.gov (United States)

    Rusciani, Antonio; Curinga, Giuseppe; Menichini, Giulio; Alfano, Carmine; Rusciani, Luigi

    2007-04-01

    Improvement in skin laxity can be difficult to achieve without invasive surgical procedures. Monopolar radiofrequency (RF) treatment is used by physicians to heat skin and promote tissue tightening and contouring. RF technology produces an electric current that generates heat through resistance in the dermis and subcutaneous tissue. The thermal effect depends on the conductivity features of the treated tissue. When heated, collagen fibrils will denature and contract, which is believed to lead to the observed tissue tightening. Ninety-three consecutive patients with mild to moderate laxity were included in the study. The Surgitron Dual Frequency RF (Radiowave technology, Ellman International) was used to treat skin laxity. The application of RF energy took place in an ambulatory setting with no need for skin sterilization or anesthesia. Patients immediately noticed a microlifting retraction in the treated tissues according to the vectors mapped in the area. There were no significant complications and the majority of patients were satisfied with the procedure and able to return to their daily routine after leaving the office, thereby substantiating the popularity of noninvasive rejuvenating procedures.

  18. Joint laxity and the relationship between muscle strength and functional ability in patients with osteoarthritis of the knee.

    Science.gov (United States)

    van der Esch, M; Steultjens, M; Knol, D L; Dinant, H; Dekker, J

    2006-12-15

    To establish the impact of knee joint laxity on the relationship between muscle strength and functional ability in osteoarthritis (OA) of the knee. A cross-sectional study of 86 patients with OA of the knee was conducted. Tests were performed to determine varus-valgus laxity, muscle strength, and functional ability. Laxity was assessed using a device that measures the angular deviation of the knee in the frontal plane. Muscle strength was measured using a computer-driven isokinetic dynamometer. Functional ability was assessed by observation (100-meter walking test) and self report (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]). Regression analyses were performed to assess the impact of joint laxity on the relationship between muscle strength and functional ability. In regression analyses, the interaction between muscle strength and joint laxity contributed to the variance in both walking time (P = 0.002) and WOMAC score (P = 0.080). The slope of the regression lines indicated that the relationship between muscle strength and functional ability (walking time, WOMAC) was stronger in patients with high knee joint laxity. Patients with knee OA and high knee joint laxity show a stronger relationship between muscle strength and functional ability than patients with OA and low knee joint laxity. Patients with OA, high knee joint laxity, and low muscle strength are most at risk of being disabled.

  19. A distinct form of spondyloepimetaphyseal dysplasia with joint laxity (SEMDJL)-leptodactylic type: radiological characteristics in seven new patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok-Hwa [Ajou University Hospital, Department of Radiology, Suwon (Korea); Cho, Tae-Joon [Seoul National University Children' s Hospital, Department of Orthopaedic Surgery, Seoul (Korea); Song, Hae-Ryong [Korea University Guro Hospital, Department of Othopaedic Surgery, Seoul (Korea); Chung, Chin Youb [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Gyeonggi (Korea); Miyagawa, Shin-Ichiro [National Hospital Organization Kure Medical center, Department of Pediatrics, Hiroshima (Japan); Nishimura, Gen [Kiyose Children' s Hospital, Department of Radiology, Tokyo (Japan); Superti-Furga, Andrea [University of Freiburg, Departement of Pediatrics, Freiburg (Germany); Unger, Sheila [Institute of Human Genetics, University of Freiburg, Freiburg (Germany)

    2009-08-15

    This study presents seven cases of a rare but distinctive form of spondyloepimetaphyseal dysplasia with joint laxity-leptodactylic or Hall type to emphasize the characteristic clinical and radiological findings. A multiinstitutional retrospective review was performed on seven patients. The patient population consisted of one family with an affected mother and two siblings and four unrelated patients; there were one adult, aged 40 years, and six children, ranging in age from 3 to 12 years. The gender ratio of females to males was 5 to 2. We reviewed the clinical data and skeletal surveys and focused on radiographs of the pelvis, knees, hands, and spine. The outstanding clinical features were short stature, midface hypoplasia, and multiple dislocations and/or ligamentous laxity of the large joints, particularly at the knees with a genu valgum or varum deformity. Of seven patients, six patients showed normal intellect but one patient had mild mental retardation. The main radiological features included small, irregular epiphyses, metaphyseal irregularity with vertical striations that was a constant finding at the knees, constricted femoral necks, delayed ossification of the carpal bones, and slender metacarpals. Progressive thoracolumbar scoliosis was evident with aging; however, the vertebral bodies appeared normal in height or mild platyspondyly was noted. In view of the orthopedic management of multiple joint dislocations and ligamentous laxity of the large joints, awareness of this disease entity and diagnostic precision solely based on radiological findings is of importance, particularly as the disorder is currently more common than initially reported. (orig.)

  20. A distinct form of spondyloepimetaphyseal dysplasia with joint laxity (SEMDJL)-leptodactylic type: radiological characteristics in seven new patients

    International Nuclear Information System (INIS)

    Kim, Ok-Hwa; Cho, Tae-Joon; Song, Hae-Ryong; Chung, Chin Youb; Miyagawa, Shin-Ichiro; Nishimura, Gen; Superti-Furga, Andrea; Unger, Sheila

    2009-01-01

    This study presents seven cases of a rare but distinctive form of spondyloepimetaphyseal dysplasia with joint laxity-leptodactylic or Hall type to emphasize the characteristic clinical and radiological findings. A multiinstitutional retrospective review was performed on seven patients. The patient population consisted of one family with an affected mother and two siblings and four unrelated patients; there were one adult, aged 40 years, and six children, ranging in age from 3 to 12 years. The gender ratio of females to males was 5 to 2. We reviewed the clinical data and skeletal surveys and focused on radiographs of the pelvis, knees, hands, and spine. The outstanding clinical features were short stature, midface hypoplasia, and multiple dislocations and/or ligamentous laxity of the large joints, particularly at the knees with a genu valgum or varum deformity. Of seven patients, six patients showed normal intellect but one patient had mild mental retardation. The main radiological features included small, irregular epiphyses, metaphyseal irregularity with vertical striations that was a constant finding at the knees, constricted femoral necks, delayed ossification of the carpal bones, and slender metacarpals. Progressive thoracolumbar scoliosis was evident with aging; however, the vertebral bodies appeared normal in height or mild platyspondyly was noted. In view of the orthopedic management of multiple joint dislocations and ligamentous laxity of the large joints, awareness of this disease entity and diagnostic precision solely based on radiological findings is of importance, particularly as the disorder is currently more common than initially reported. (orig.)

  1. Injuries and disorders among young ice skaters: relationship with generalized joint laxity and tightness

    Directory of Open Access Journals (Sweden)

    Okamura S

    2014-08-01

    Full Text Available Shinobu Okamura,1 Naoki Wada,1 Masayuki Tazawa,1 Makoto Sohmiya,1 Yoko Ibe,1 Toru Shimizu,1 Shigeru Usuda,2 Kenji Shirakura1 1Department of Rehabilitation Medicine, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan; 2Department of Physical Therapy, Gunma University School of Health Science, Maebashi, Gunma, Japan Abstract: This study retrospectively investigated 192 teenage speed and figure skaters with prior injuries documented by an athletes’ questionnaire, who underwent a physical examination to assess their muscle tightness and generalized joint laxity. In all athletes, the degree of muscle tightness and joint laxity were measured by a standardized physical examination. A descriptive report of the types of injuries showed a predominance of fractures, ligament injuries, enthesitis, and lower back pain. Approximately 5% of all skaters tested positive for tightness, while 25.8% of figure skaters and 15.2% of speed skaters had generalized ligamentous laxity. Statistical testing showed an association between ankle sprains and muscle tightness, and an association between knee enthesitis and muscle tightness in skating athletes. There was also an association between lower back pain and generalized joint laxity, which held true only for the male skaters. Keywords: sports injury, skating, junior athlete, tightness, joint laxity, medical checkup

  2. Comparison between clinical grading and navigation data of knee laxity in ACL-deficient knees

    Directory of Open Access Journals (Sweden)

    Yamamoto Yuji

    2010-11-01

    Full Text Available Abstract Background The latest version of the navigation system for anterior cruciate ligament (ACL reconstruction has the supplementary ability to assess knee stability before and after ACL reconstruction. In this study, we compared navigation data between clinical grades in ACL-deficient knees and also analyzed correlation between clinical grading and navigation data. Methods 150 ACL deficient knees that received primary ACL reconstruction using an image-free navigation system were included. For clinical evaluation, the Lachman, anterior drawer, and pivot shift tests were performed under general anesthesia and were graded by an examiner. For the assessment of knee stability using the navigation system, manual tests were performed again before ACL reconstruction. Navigation data were recorded as anteroposterior (AP displacement of the tibia for the Lachman and anterior drawer tests, and both AP displacement and tibial rotation for the pivot shift test. Results Navigation data of each clinical grade were as follows; Lachman test grade 1+: 10.0 mm, grade 2+: 13.2 ± 3.1 mm, grade 3+: 14.5 ± 3.3 mm, anterior drawer test grade 1+: 6.8 ± 1.4 mm, grade 2+: 7.4 ± 1.8 mm, grade 3+: 9.1 ± 2.3 mm, pivot shift test grade 1+: 3.9 ± 1.8 mm/21.5° ± 7.8°, grade 2+: 4.8 ± 2.1 mm/21.8° ± 7.1°, and grade 3+: 6.0 ± 3.2 mm/21.1° ± 7.1°. There were positive correlations between clinical grading and AP displacement in the Lachman, and anterior drawer tests. Although positive correlations between clinical grading and AP displacement in pivot shift test were found, there were no correlations between clinical grading and tibial rotation in pivot shift test. Conclusions In response to AP force, the navigation system can provide the surgeon with correct objective data for knee laxity in ACL deficient knees. During the pivot shift test, physicians may grade according to the displacement of the tibia, rather than rotation.

  3. Involutional ectropion and entropion: clinicopathologic correlation between horizontal eyelid laxity and eyelid extracellular matrix.

    Science.gov (United States)

    Damasceno, Renato Wendell; Osaki, Midori Hentona; Dantas, Paulo Elias Correa; Belfort, Rubens

    2011-01-01

    To investigate the clinicopathologic correlation between horizontal eyelid laxity and extracellular matrix components, such as collagen and elastic fibers, in involutional ectropion and entropion. Another goal was to compare the differences between involutional ectropion and entropion in regard to extracellular matrix content using computer-assisted morphometry. This clinicopathologic study included 20 consecutive patients with involutional ectropion (group 1) and 20 consecutive patients with involutional entropion (group 2). The pinch test was performed to measure horizontal eyelid laxity in both groups. Full-thickness eyelid biopsy specimens were examined by light microscopy and computer-assisted morphometry. The Mann-Whitney U test, the Pearson chi-square test, the Pearson correlation coefficient calculation, and a linear regression analysis were performed. All sections of specimens from patients in groups 1 and 2 revealed abnormal collagen and elastic fibers. The Pearson correlation coefficient revealed a significant negative correlation between horizontal eyelid laxity and extracellular matrix content in the eyelid skin, the pretarsal orbicularis oculi muscle, the perimeibomian tarsal stroma, and the intermeibomian tarsal stroma. Linear regression demonstrated that horizontal eyelid laxity is dependent upon extracellular matrix components in all eyelid regions. Collagen fiber content was significantly increased in specimens from patients in group 1 compared with specimens from patients in group 2. The present findings suggest that a reduction of collagen and elastic fibers may contribute to the development of excessive horizontal eyelid laxity in patients with involutional ectropion and entropion of the lower eyelid.

  4. Radiofrequency for the treatment of skin laxity: mith or truth*

    Science.gov (United States)

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  5. Two ankle joint laxity testers: reliability and validity

    NARCIS (Netherlands)

    Kerkhoffs, Gino M. M. J.; Blankevoort, Leendert; Sierevelt, Inger N.; Corvelein, Ruby; Janssen, Guido H. W.; van Dijk, C. Niek

    2005-01-01

    Two test devices were manufactured to objectively measure ankle joint laxity: the dynamic anterior ankle tester (DAAT) and the quasi-static anterior ankle tester (QAAT). The primary aim was to analyse the reliability of both testers; The secondary aim was to assess validity in correlation with TELOS

  6. Lower Lid Laxity is Negatively Correlated with Improvement of the Ocular Surface Disease Index in Dry Eye Treatment.

    Science.gov (United States)

    Oh, Seung Hoon; Lyu, Byul; Yim, Hye Bin; Lee, Na Young

    2016-01-01

    To compare the responses to dry eye treatment of patients sorted by the degree of lower lid laxity. Sixty patients were grouped into three groups according to the degree of lower lid laxity. Tear break-up time (TBUT), Schirmer test (ST) scores, ocular surface disease index (OSDI) scores, and changes in OSDI score in each group were compared, before and at 3 months after treatment. TBUT, ST, and OSDI scores were not different among the three groups at baseline. TBUT improved in each group at 3 months after treatment, and no differences between groups were found. ST scores were not increased after treatment, while OSDI were improved to 22.57 ± 5.243, 31.16 ± 11.353, and 37.85 ± 13.342 in the no, moderate, and high laxity groups, respectively; these improvements were statistically significant (p = 0.003, dry eye treatment, as assessed by change in OSDI score (p = 0.005 versus moderate laxity group, p = 0.005 versus no laxity group). Lower lid laxity is one of the factors contributing to the responses to dry eye treatment assessed by change in OSDI score, independent of TBUT and ST scores.

  7. Treatment of peroneal tendon dislocation and coexisting medial and lateral ligamentous laxity in the ankle joint.

    Science.gov (United States)

    Ziai, Pejman; Sabeti-Aschraf, Manuel; Fehske, Kai; Dlaska, Constantin E; Funovics, Philipp; Wenzel, Florian; Graf, Alexandra; Buchhorn, Tomas

    2011-06-01

    Acute dislocation of the peroneal tendon is caused by massive combined flexion-torsion trauma supported by preexisting ligamentous laxity of the ankle joint. This study aimed to investigate the clinical outcome of combined treatment of peroneal tendon dislocation and lateral and medial ligamentous laxity. Between 2005 and 2007, forty-two patients with peroneal tendon dislocation and coexisting ligamentous laxity were treated. The superior extensor retinaculum was reconstructed using anchor technique and periosteal flap repair, whereas the preexisting ligamentous laxity with regard to the extensor inferior retinaculum was addressed using anchor reconstruction. All patients underwent arthroscopy prior to surgery. Thirty-eight of a total of 42 patients (aged 17-31) completed the 24-month follow-up. Clinical and arthroscopic examination was accomplished consistently by always the same two surgeons. Postoperative follow-up comprised clinical evaluation after 3, 6, 12 and 24 months. Clinical results showed a significant (Pankle joint following arthroscopy results in good clinical outcome and high patient satisfaction. Case series, Level IV.

  8. Noninjured Knees of Patients With Noncontact ACL Injuries Display Higher Average Anterior and Internal Rotational Knee Laxity Compared With Healthy Knees of a Noninjured Population.

    Science.gov (United States)

    Mouton, Caroline; Theisen, Daniel; Meyer, Tim; Agostinis, Hélène; Nührenbörger, Christian; Pape, Dietrich; Seil, Romain

    2015-08-01

    Excessive physiological anterior and rotational knee laxity is thought to be a risk factor for noncontact anterior cruciate ligament (ACL) injuries and inferior reconstruction outcomes, but no thresholds have been established to identify patients with increased laxity. (1) To determine if the healthy contralateral knees of ACL-injured patients have greater anterior and rotational knee laxity, leading to different laxity profiles (combination of laxities), compared with healthy control knees and (2) to set a threshold to help discriminate anterior and rotational knee laxity between these groups. Case-sectional study; Level of evidence, 3. A total of 171 healthy contralateral knees of noncontact ACL-injured patients (ACL-H group) and 104 healthy knees of control participants (CTL group) were tested for anterior and rotational laxity. Laxity scores (measurements corrected for sex and body mass) were used to classify knees as hypolax (score 1). Proportions of patients in each group were compared using χ(2) tests. Receiver operating characteristic curves were computed to discriminate laxity between the groups. Odds ratios were calculated to determine the probability of being in the ACL-H group. The ACL-H group displayed greater laxity scores for anterior displacement and internal rotation in their uninjured knee compared with the CTL group (P knees of patients with noncontact ACL injuries display different laxity values both for internal rotation and anterior displacement compared with healthy control knees. The identification of knee laxity profiles may be of relevance for primary and secondary prevention programs of noncontact ACL injuries. © 2015 The Author(s).

  9. Treatment of facial skin laxity by a new monopolar radiofrequency device

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2011-01-01

    Full Text Available Background : Acquired facial skin laxity seems to be a result of the combination of intrinsic and extrinsic processes. For treatment of facial ageing, non-invasive procedures have become popular. Aim : We wanted to investigate the effect of a new 2.2-MHz radiofrequency (RF device on acquired facial skin laxity. Setting : Outpatient clinic associated with an academic teaching hospital. Materials and Methods : We performed an open trial with the RF-ReFacing™ device (Meyer-Haake Medical Innovations, Wehrheim/ Germany in the monopolar mode with a power of 8-12 W, two passes per session and repetition three times after 2 weeks without treatment. Results : A total of 20 Caucasian female patients were included (age range, 34-73 years. The procedure was performed without any analgesia. We did not see any adverse effect. The procedure was scored as most convenient or convenient by all patients. Improvement in skin laxity and fine wrinkles was seen after the second treatment in 19 of the 20 patients and after the third treatment in 100% of the patients. On a scale from 0 to 3, improvement in the lower lid, Crow′s feet and jowl line was scored 2.6±0.7 by the patients; improvement in the overall appearance of the face was scored 2.3±0.5. Blinded assessment of the photographs rated the improvement as good or better in 15 of the 20 patients, moderate in 3 patients, no change in 1 patient. Conclusions : RF-ReFacing™ treatment was effective in improvement in skin laxity. Patients′ satisfaction was high. Although RF-ReFacing™ treatment cannot substitute surgical procedure, it might prolong the time to the first surgical facial lift. The number of patients treated was small, and no quantitative measurements or histopathology was performed. Hence further studies with greater number of patients are necessary.

  10. Human Papillomavirus 16 (HPV-16), HPV-18, and HPV-31 E6 Override the Normal Phosphoregulation of E6AP Enzymatic Activity.

    Science.gov (United States)

    Thatte, Jayashree; Banks, Lawrence

    2017-11-15

    The human papillomavirus (HPV) E6 oncoproteins recruit the cellular ubiquitin ligase E6AP/UBE3A to target cellular substrates for proteasome-mediated degradation, and one consequence of this activity is the E6 stimulation of E6AP autoubiquitination and degradation. Recent studies identified an autism-linked mutation within E6AP at T485, which was identified as a protein kinase A phosphoacceptor site and which could directly regulate E6AP ubiquitin ligase activity. In this study, we have analyzed how T485-mediated regulation of E6AP might affect E6 targeting of some of its known substrates. We show that modulation of T485 has no effect on the ability of E6 to direct either p53 or Dlg for degradation. Furthermore, T485 regulation has no effect on HPV-16 or HPV-31 E6-induced autodegradation of E6AP but does affect HPV-18 E6-induced autodegradation of E6AP. In cells derived from cervical cancers, we find low levels of both phosphorylated and nonphosphorylated E6AP in the nucleus. However, ablation of E6 results in a dramatic accumulation of phospho-E6AP in the cytoplasm, whereas nonphosphorylated E6AP accumulates primarily in the nucleus. Interestingly, E6AP phosphorylation at T485 confers association with 14-3-3 proteins, and this interaction seems to be important, in part, for the ability of E6 to recruit phospho-E6AP into the nucleus. These results demonstrate that HPV E6 overrides the normal phosphoregulation of E6AP, both in terms of its enzymatic activity and its subcellular distribution. IMPORTANCE Recent reports demonstrate the importance of phosphoregulation of E6AP for its normal enzymatic activity. Here, we show that HPV E6 is capable of overriding this regulation and can promote degradation of p53 and Dlg regardless of the phosphorylation status of E6AP. Furthermore, E6 interaction with E6AP also significantly alters how E6AP is subject to autodegradation and suggests that this is not a simple stimulation of an already-existing activity but rather a

  11. Dwarfism with joint laxity in Friesian horses is associated with a splice site mutation in B4GALT7

    OpenAIRE

    Leegwater, Peter A.; Vos-Loohuis, Manon; Ducro, Bart J.; Boegheim, Iris J.; van Steenbeek, Frank G.; Nijman, Isaac J.; Monroe, Glen R.; Bastiaansen, John W. M.; Dibbits, Bert W.; van de Goor, Leanne H.; Hellinga, Ids; Back, Willem; Schurink, Anouk

    2016-01-01

    Background Inbreeding and population bottlenecks in the ancestry of Friesian horses has led to health issues such as dwarfism. The limbs of dwarfs are short and the ribs are protruding inwards at the costochondral junction, while the head and back appear normal. A striking feature of the condition is the flexor tendon laxity that leads to hyperextension of the fetlock joints. The growth plates of dwarfs display disorganized and thickened chondrocyte columns. The aim of this study was to ident...

  12. Dwarfism with joint laxity in Friesian horses is associated with a splice site mutation in B4GALT7

    OpenAIRE

    Leegwater, Peter A.; Vos-Loohuis, Manon; Ducro, Bart J.; Boegheim, Iris J.; Bastiaansen, John W.M.; Dibbits, Bert W.; Schurink, Anouk

    2016-01-01

    Background: Inbreeding and population bottlenecks in the ancestry of Friesian horses has led to health issues such as dwarfism. The limbs of dwarfs are short and the ribs are protruding inwards at the costochondral junction, while the head and back appear normal. A striking feature of the condition is the flexor tendon laxity that leads to hyperextension of the fetlock joints. The growth plates of dwarfs display disorganized and thickened chondrocyte columns. The aim of this study was to iden...

  13. Clinical signs in the foot that are predictors of ligamentous laxity in the adult population.

    Science.gov (United States)

    Benhamú-Benhamú, Salomón; Domínguez-Maldonado, Gabriel; García-De-La-Peña, Raquel; Jiménez-Cristino, María Dolores; Gijon-Nogueron, Gabriel

    2015-11-01

    This study evaluates the influence of ligamentous laxity on the foot from observation of clinical signs and quantification of certain joint ranges. The sample consisted of 400 subjects - 200 in the non-lax control group (ages 32.49 ± 11.06 years) and 200 in the lax group (ages 29.82 ± 9.41 years). The Beighton criteria were applied to each subject to diagnose laxity or non-laxity after noting their gender, age, and 2 joint ranges and 2 clinical signs for both feet. This was an observational analytical study of cases and controls, in which a multivariate binary logistic regression model was applied. Extension of the first metatarsophalangeal joint (MTPJ) ≥95°, extension of the 1st toe's interphalangeal joint (IPJ) ≥14°, and the signs 1st "in the plantar footprint, marked and narrowly confined support under metatarsal heads" and 2nd "in the plantar footprint, continuity of the 1st toe to the 1st metatarsal" presented significant differences between the lax and the non-lax groups. These are usable as parameters with which to detect laxity. The Beighton criteria were confirmed as being the most appropriate for diagnosis. We propose the use of 2 clinical signs that can be evaluated in plantar footprints ("1st" and "2nd") and 2 exploratory manoeuvres (extension of the first MTPJ ≥95° and extension of the 1st toe's IPJ ≥14°) as factors present in the foot which allow the detection of ligamentous laxity in the adult population, for subsequent confirmation by applying the Beighton criteria. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  14. Focal vibration of quadriceps muscle enhances leg power and decreases knee joint laxity in female volleyball players.

    Science.gov (United States)

    Brunetti, O; Botti, F M; Roscini, M; Brunetti, A; Panichi, R; Filippi, G M; Biscarini, A; Pettorossi, V E

    2012-12-01

    This double-blind randomized controlled study aims at determining the effect of repeated muscle vibration (rMV) on explosive and reactive leg power and on knee laxity of female volleyball players. Eighteen voluntary volleyball athletes, belonging to the same senior regional level team (age=22.7 ± 3 years, height=180.3 ± 5 cm, mass= 64 ± 4 kg) were assigned to three groups (N.=6) for vibration on contracted quadriceps (VC), vibration on relaxed muscle (VR), and sham vibration (NV), respectively. Intervention consisted in 3 rMV sessions performed in 3 consecutive days. In each session, 100 Hz, 300-500 μm amplitude vibratory stimuli were bilaterally delivered to the quadriceps in three consecutive 10-minutes applications. Explosive and reactive leg power and knee joint laxity were evaluated 1 day before, and 1, 30, and 240 days after intervention. In VC group, explosive and reactive leg power increased respectively by ~16% and ~9% at 1 day, by ~19% and ~11% at 30 days and by ~26% and ~13% at 240 days, concomitantly knee laxity decreased by ~6%, ~15% and ~18% at the same times. These changes were significantly larger than in the other groups, in which leg power increment and knee joint laxity reduction remained close to ~3%, ~5% and ~10% at 1, 30 and 240 days, respectively. Combined bilateral voluntary contraction and rMV of the quadriceps muscles is a short-lasting, non-invasive technique that can significantly and persistently improve muscle performance and knee laxity in volleyball women players.

  15. Knee joint laxity does not moderate the relationship between quadriceps strength and physical function in knee osteoarthritis patients: A cross-sectional study.

    Science.gov (United States)

    Altubasi, Ibrahim M

    2018-06-07

    Knee osteoarthritis is a common and a disabling musculoskeletal disorder. Patients with knee osteoarthritis have activity limitations which are linked to the strength of the quadriceps muscle. Previous research reported that the relationship between quadriceps muscle strength and physical function is moderated by the level of knee joint frontal plane laxity. The purpose of the current study is to reexamine the moderation effect of the knee joint laxity as measured by stress radiographs on the relationship between quadriceps muscle strength and physical function. One-hundred and sixty osteoarthritis patients participated in this cross-sectional study. Isometric quadriceps muscle strength was measured using an isokinetic dynamometer. Self-rated and performance-based physical function were measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical function subscale and Get Up and Go test, respectively. Stress radiographs which were taken while applying varus and valgus loads to knee using the TELOS device. Knee joint laxity was determined by measuring the distance between joint surfaces on the medial and lateral sides. Hierarchical multiple regression models were constructed to study the moderation effect of laxity on the strength function relationship. Two regression models were constructed for self-rated and performance-based function. After controlling for demographics, strength contributed significantly in the models. The addition of laxity and laxity-strength interaction did not add significant contributions in the regression models. Frontal plane knee joint laxity measured by stress radiographs does not moderate the relationship between quadriceps muscle strength and physical function in patients with osteoarthritis. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. High-Intensity Focused Ultrasound for the Treatment of Wrinkles and Skin Laxity in Seven Different Facial Areas

    OpenAIRE

    Park, Hyunchul; Kim, Eunjin; Kim, Jeongeun; Ro, Youngsuck; Ko, Jooyeon

    2015-01-01

    Background High-intensity focused ultrasound (HIFU) treatment has recently emerged in response to the increasing demand for noninvasive procedures for skin lifting and tightening. Objective This study was aimed at evaluating the clinical efficacy of and patient satisfaction with HIFU treatment for wrinkles and laxity in seven different areas of the face in Asian skin. Methods Twenty Korean patients with facial wrinkle and laxity were analyzed after a single session of HIFU treatment. Two inde...

  17. Whiplash causes increased laxity of cervical capsular ligament

    Science.gov (United States)

    Ivancic, Paul C.; Ito, Shigeki; Tominaga, Yasuhiro; Rubin, Wolfgang; Coe, Marcus P.; Ndu, Anthony B.; Carlson, Erik J.; Panjabi, Manohar M.

    2009-01-01

    Background Previous clinical studies have identified the cervical facet joint, including the capsular ligaments, as sources of pain in whiplash patients. The goal of this study was to determine whether whiplash caused increased capsular ligament laxity by applying quasi-static loading to whiplash-exposed and control capsular ligaments. Methods A total of 66 capsular ligament specimens (C2/3 to C7/T1) were prepared from 12 cervical spines (6 whiplash-exposed and 6 control). The whiplash-exposed spines had been previously rear impacted at a maximum peak T1 horizontal acceleration of 8 g. Capsular ligaments were elongated at 1 mm/s in increments of 0.05 mm until a tensile force of 5 N was achieved and subsequently returned to neutral position. Four pre-conditioning cycles were performed and data from the load phase of the fifth cycle were used for subsequent analyses. Ligament elongation was computed at tensile forces of 0, 0.25, 0.5, 0.75, 1.0, 2.5, and 5.0 N. Two factor, non-repeated measures ANOVA (Pwhiplash-exposed and control groups and between spinal levels. Findings Average elongation of the whiplash-exposed capsular ligaments was significantly greater than that of the control ligaments at tensile forces of 0 and 5 N. No significant differences between spinal levels were observed. Interpretation Capsular ligament injuries, in the form of increased laxity, may be one component perpetuating chronic pain and clinical instability in whiplash patients. PMID:17959284

  18. Whiplash causes increased laxity of cervical capsular ligament.

    Science.gov (United States)

    Ivancic, Paul C; Ito, Shigeki; Tominaga, Yasuhiro; Rubin, Wolfgang; Coe, Marcus P; Ndu, Anthony B; Carlson, Erik J; Panjabi, Manohar M

    2008-02-01

    Previous clinical studies have identified the cervical facet joint, including the capsular ligaments, as sources of pain in whiplash patients. The goal of this study was to determine whether whiplash caused increased capsular ligament laxity by applying quasi-static loading to whiplash-exposed and control capsular ligaments. A total of 66 capsular ligament specimens (C2/3 to C7/T1) were prepared from 12 cervical spines (6 whiplash-exposed and 6 control). The whiplash-exposed spines had been previously rear impacted at a maximum peak T1 horizontal acceleration of 8 g. Capsular ligaments were elongated at 1mm/s in increments of 0.05 mm until a tensile force of 5 N was achieved and subsequently returned to neutral position. Four pre-conditioning cycles were performed and data from the load phase of the fifth cycle were used for subsequent analyses. Ligament elongation was computed at tensile forces of 0, 0.25, 0.5, 0.75, 1.0, 2.5, and 5.0 N. Two factor, non-repeated measures ANOVA (Pwhiplash-exposed and control groups and between spinal levels. Average elongation of the whiplash-exposed capsular ligaments was significantly greater than that of the control ligaments at tensile forces of 0 and 5 N. No significant differences between spinal levels were observed. Capsular ligament injuries, in the form of increased laxity, may be one component perpetuating chronic pain and clinical instability in whiplash patients.

  19. Comparison of dynamic ultrasound and stress radiology for assessment of inferior glenohumeral laxity in asymptomatic shoulders

    International Nuclear Information System (INIS)

    Cheng, S.C.; Wallace, W.A.; Hulse, D.; Fairbairn, K.J.; Clarke, M.

    2008-01-01

    To determine the level of agreement between dynamic ultrasound imaging and stress radiography used for the measurement of inferior glenohumeral laxity in asymptomatic shoulders, and to determine the repeatability of the dynamic ultrasound technique. Using a custom-made stress device to apply an inferior displacement force of 90 N, we assessed 20 asymptomatic male subjects for inferior glenohumeral laxity, using stress radiography and dynamic ultrasound. Paired differences between the two methods were evaluated by the 95% limits of agreement method. At a separate session, 19 subjects had inferior glenohumeral laxity assessed by two observers, using dynamic ultrasound. Inter- and intra-observer repeatability was determined for the ultrasound technique. The mean [± standard deviation (SD)] inferior translation was 4.7 ± 4.1 mm by stress radiography and 4.4 ± 2.3 mm by dynamic ultrasound. The 95% limits of agreement showed good agreement between the two methods. The paired difference between the two measurement methods varied with the magnitude of the measurement (P < 0.001). Intra-observer repeatability of dynamic ultrasound was determined by the use of intra-class correlation coefficients and was 0.94 and 0.89 for the two investigators. Inter-observer repeatability was 0.85. The standard error of the measurement was 0.60 mm and 0.66 mm, for repeated measurements by the two investigators, and 0.85 mm between investigators. Repeatability coefficients demonstrated excellent consistency of measurement between sessions and good consistency between observers. Dynamic ultrasound is a valid and reproducible method for the assessment and quantification of inferior glenohumeral laxity. (orig.)

  20. Carpal ligamentous laxity with bilateral perilunate dislocation in Marfan syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Pennes, D R; Braunstein, E M; Shirazi, K K

    1985-01-01

    A case of persistent bilateral perilunate dislocation unrelated to trauma in a patient with Marfan syndrome is discussed. This finding is believed to be a manifestation of the generalized ligamentous laxity occurring in this disorder. Radiographs of eight additional Marfan syndrome patients failed to demonstrate similar carpal instability. Because some carpal derangements are dynamic events, stress views or wrist fluoroscopy may be necessary to demonstrate unsuspected carpal instability in Marfan patients.

  1. Carpal ligamentous laxity with bilateral perilunate dislocation in Marfan syndrome

    International Nuclear Information System (INIS)

    Pennes, D.R.; Braunstein, E.M.; Shirazi, K.K.

    1985-01-01

    A case of persistent bilateral perilunate dislocation unrelated to trauma in a patient with Marfan syndrome is discussed. This finding is believed to be a manifestation of the generalized ligamentous laxity occurring in this disorder. Radiographs of eight additional Marfan syndrome patients failed to demonstrate similar carpal instability. Because some carpal derangements are dynamic events, stress views or wrist fluoroscopy may be necessary to demonstrate unsuspected carpal instability in Marfan patients. (orig.)

  2. Evaluation of a microfocused ultrasound system for improving skin laxity and tightening in the lower face.

    Science.gov (United States)

    Oni, Georgette; Hoxworth, Ron; Teotia, Sumeet; Brown, Spencer; Kenkel, Jeffrey M

    2014-09-01

    The Ulthera System (Ulthera, Inc, Mesa, Arizona) employs microfocused ultrasound to cause discrete focal heating of the dermis and stimulate neocollagenesis and elastin remodeling. The authors investigated tightening and lifting of cheek tissue, improvement in jawline definition, and reduction in submental skin laxity in patients treated with the Ulthera System. A total of 103 adults were enrolled in this prospective nonrandomized clinical trial. Three-dimensional photographs obtained at baseline and 3 months posttreatment were assessed qualitatively by 3 blinded reviewers and quantitatively with AutoCAD software (Informer Technologies, Redwood City, California). The relationship between outcomes and body mass index (BMI) was examined as well. Patients rated pain during the procedure and provided subjective assessment of their outcome at 90 days. Adverse events were documented. Ninety-three patients were evaluated. Blinded reviewers observed improvement in skin laxity in 58.1% of patients. During quantitative assessments, overall improvement in skin laxity was noted in 63.6% of evaluated patients. No change was detected in 54.5% of patients whose BMI exceeded 30 kg/m2 or in 12.2% of patients whose BMI was ≤30 kg/m2. At day 90, 65.6% of patients perceived improvement in the skin laxity of the lower half of their face/neck. The average procedural pain scores for the cheek, submental, and submandibular regions were 5.68, 6.09, and 6.53, respectively. Wheals, which resolved without intervention or long-term sequelae, were reported for 3 patients. To the authors' knowledge, this is the largest clinical study of the effectiveness of the Ulthera System for rejuvenation of the lower face. At day 90, improvements were reported by two-thirds of patients and by nearly 60% of blinded reviewers. Outcomes were better in patients with BMI≤30 kg/m2. 2. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  3. Three-dimensional bone kinematics in an anterior laxity test of the ankle joint

    NARCIS (Netherlands)

    Kerkhoffs, G.; Blankevoort, L.; Kingma, I.; van Dijk, C.N.

    2007-01-01

    Questions addressed in this in-vitro study are (1) what are the actual three-dimensional kinematics of talus and calcaneus during an anterior drawer test as performed with the quasi-static anterior ankle tester (QAAT) (2) does laxity measurement with the QAAT represent the true anterior translation

  4. Chronic neck pain: making the connection between capsular ligament laxity and cervical instability.

    Science.gov (United States)

    Steilen, Danielle; Hauser, Ross; Woldin, Barbara; Sawyer, Sarah

    2014-01-01

    The use of conventional modalities for chronic neck pain remains debatable, primarily because most treatments have had limited success. We conducted a review of the literature published up to December 2013 on the diagnostic and treatment modalities of disorders related to chronic neck pain and concluded that, despite providing temporary relief of symptoms, these treatments do not address the specific problems of healing and are not likely to offer long-term cures. The objectives of this narrative review are to provide an overview of chronic neck pain as it relates to cervical instability, to describe the anatomical features of the cervical spine and the impact of capsular ligament laxity, to discuss the disorders causing chronic neck pain and their current treatments, and lastly, to present prolotherapy as a viable treatment option that heals injured ligaments, restores stability to the spine, and resolves chronic neck pain. The capsular ligaments are the main stabilizing structures of the facet joints in the cervical spine and have been implicated as a major source of chronic neck pain. Chronic neck pain often reflects a state of instability in the cervical spine and is a symptom common to a number of conditions described herein, including disc herniation, cervical spondylosis, whiplash injury and whiplash associated disorder, postconcussion syndrome, vertebrobasilar insufficiency, and Barré-Liéou syndrome. When the capsular ligaments are injured, they become elongated and exhibit laxity, which causes excessive movement of the cervical vertebrae. In the upper cervical spine (C0-C2), this can cause a number of other symptoms including, but not limited to, nerve irritation and vertebrobasilar insufficiency with associated vertigo, tinnitus, dizziness, facial pain, arm pain, and migraine headaches. In the lower cervical spine (C3-C7), this can cause muscle spasms, crepitation, and/or paresthesia in addition to chronic neck pain. In either case, the presence of

  5. Clinical features of secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation

    Directory of Open Access Journals (Sweden)

    Yi Ma

    2018-04-01

    Full Text Available AIM: To investigate the clinical characteristics of secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation, and to analyze the influence of operation on visual acuity and intraocular pressure(IOP. METHODS: Totally 38 cases(38 eyesof the secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation in ophthalmology department of our hospital from December 2014 to December 2016 were enrolled and their medical records were analyzed retrospectively to observe the clinical characteristics of glaucoma. Preoperative mydriasis was carried out and surgical methods were chosen according to the lenses location and extent of suspensory ligament. Preoperative and postoperative anterior chamber depth, corneal endothelial cell density, IOP, visual field, visual acuity and complications were analyzed. RESULTS: The average intraocular pressure was 18.17±1.43mmHg at postoperatively 10d, which was significantly lower than 38.77±2.45mmHg before operation, the difference had statistical significance(PP>0.05. The postoperative anterior chamber depth was 2.45±0.44mm, which was significantly higher than 1.23±0.35mm before operation, the difference had statistical significance(P2 and decreased significantly, compared with 1735.32±340.32/mm2 before operation, the difference had statistical significance(PCONCLUSION: Clinical symptoms and signs of secondary glaucoma in patients with lens suspensory ligament laxity or occult subluxation are more complex, which needs to be distinguished with other types of glaucoma in clinical treatment, and its surgical methods shall be chosen according to different suspensory ligament site and lens subluxation scope.

  6. Split-face comparison of radiofrequency versus long-pulse Nd-YAG treatment of facial laxity.

    Science.gov (United States)

    Taylor, Mark B; Prokopenko, Inna

    2006-04-01

    To improve photoaging skin with laser treatment, multiple sessions have been considered necessary to achieve results comparable with one radiofrequency (RF) treatment. We compared single-treatment improvements obtained by the long-pulse 1064 nm Nd:YAG laser and RF device. In a split-face study, patients with sagging skin were treated once with laser (left side) and once with RF (right side) energy. Improvement judged by six blinded observers was greater for wrinkles and laxity (30% median) on the laser-treated side and essentially the same with both modalities (15% median) for texture, pores, and pigmentation. Improvement was maintained for at least 2-6 months on both facial sides without adverse effects. With a single treatment, both the long-pulse 1064 nm Nd:YAG laser and ThermaCool RF device provide a modest degree of improvement in both wrinkles and laxity of facial skin and similar improvement in texture, pores, and pigmentation.

  7. The prognostic value of asymmetric laxity of the sacroiliac joints in pregnancy-related pelvic pain.

    NARCIS (Netherlands)

    Damen, L.; Buyruk, H.M.; Guler-Uysal, F.; Lotgering, F.K.; Snijders, C.J.; Stam, H.J.

    2002-01-01

    STUDY DESIGN: Prospective cohort study. OBJECTIVE: To determine the prognostic value of asymmetric laxity of the sacroiliac joints during pregnancy on pregnancy-related pelvic pain postpartum. SUMMARY OF BACKGROUND DATA: In a previous study, we observed a significant relation between asymmetric

  8. Microfocused Ultrasound with Visualization and Calcium Hydroxylapatite for Improving Skin Laxity and Cellulite Appearance

    Science.gov (United States)

    Pereira, Gregório

    2017-01-01

    Background: Age-associated skin laxity contributes to worsening of cellulite appearance. This study evaluated the effects of microfocused ultrasound with visualization (MFU-V; Ultherapy) in combination with diluted calcium hydroxylapatite (CaHA; Radiesse) on cellulite appearance and on neocollagenesis. Methods: Twenty women (18–55 years old) with skin laxity and moderate-to-severe cellulite on the buttocks and thighs were retrospectively enrolled. MFU-V was applied using 4 and 7 MHz transducers (25 lines/transducer/site) and immediately followed by subdermal CaHA injection (1 ml/buttock or thigh). Photographs at baseline and 90 days were assessed by 2 independent, blinded evaluators using a 5-item cellulite severity scale. One subject scheduled for thighplasty received treatment with 6 different CaHA dilutions (0.3 ml/5 cm2) followed by MFU-V. Tissue specimens from each dilution site were examined under polarized light microscopy to assess neocollagenesis. Results: Both evaluators reported statistically significant improvements compared with baseline for each item on the cellulite severity scale (P treatment. At 90 days, histologic analysis showed peak neocollagenesis in samples treated with the 1:1 dilution, whether with CaHA alone or in combination with MFU-V. The highest conversion of collagen type III into collagen type I at month 3 occurred in samples injected with 1:1 and 1:0.6 CaHA dilutions without subsequent MFU-V treatment. Both procedures were well tolerated, and subject satisfaction was high. Conclusions: Combination treatment with MFU-V and diluted CaHA is effective for improving skin laxity and the appearance of cellulite on the buttocks and upper thighs. PMID:28831339

  9. Radiographic evaluation of coxofemoral joint laxity in dogs part II: Comparison of stress-radiographic positioning techniques in dogs with hip dysplasia

    International Nuclear Information System (INIS)

    Duangdaun Kaenkangploo; Phiwipha Kamonrat; Marissak Kalpravidh

    2002-01-01

    Two stress-radiographic positioning techniques for evaluation of coxofemoral joint laxity in dogs with hip dysplasia were compared with the standard technique. Forty, healthy, large breed dogs were divided into two groups of 20 dogs. Group 1 had normal hips. Group 2 were dogs with mild to moderated grade of hip dysplasia according to the Orthopedic Foundation for Animals (OFA) standard. Dogs were anesthetized and placed in dorsal recumbency before 3 radiographic techniques, standard hip-extended, 60 deg and 90 deg stress techniques, were taken. For the 60 deg stress technique, hind legs were extended in parallel to each other at 60 deg to the table top and femoral heads were manually pushed craniodorsally during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. Subluxation index (SI) and dorsolateral subluxation score (DLS score) of coxofemoral joints were assessed from radiographs. The SI of normal dogs from standard, 60 deg and 90 deg stress techniques were 0.15, 0.20 and 0.23 and of dysplastic dogs were 0.34, 0.40 and 0.41 respectively. The degress of subluxation assessed from the two stress technique radiographs were significantly greater (p0.05) than those shown on the standard technique radiographs in both groups of dogs. DLS scores of normal dogs from standard, 60 deg and 90 deg stress techniques were 65.1, 64.3 and 61.0 percent and of dysplastic dogs were 55.4, 53.6 and 47.6 percent respectively. Mean of DLS scores assessed from the 90 deg radiographs was significantly lower (p0.05) than those assessed from radiographs of other two teachniques in both groups of dogs. The findings suggested that the 90 deg stress technique is more efficient than the standard and 60 deg stress techniques for radiographic evaluation of coxofemoral joint laxity in dogs with mild hip dysplasia and early

  10. High-Intensity Focused Ultrasound for the Treatment of Wrinkles and Skin Laxity in Seven Different Facial Areas.

    Science.gov (United States)

    Park, Hyunchul; Kim, Eunjin; Kim, Jeongeun; Ro, Youngsuck; Ko, Jooyeon

    2015-12-01

    High-intensity focused ultrasound (HIFU) treatment has recently emerged in response to the increasing demand for noninvasive procedures for skin lifting and tightening. This study was aimed at evaluating the clinical efficacy of and patient satisfaction with HIFU treatment for wrinkles and laxity in seven different areas of the face in Asian skin. Twenty Korean patients with facial wrinkle and laxity were analyzed after a single session of HIFU treatment. Two independent, blinded clinicians evaluated the clinical improvement in seven areas of the face by comparison of standardized photographs obtained before, and at 3 and 6 months after treatment. Assessment of subjective satisfaction and adverse effects of treatment were done by using questionnaires. The physicians' evaluation and patients' satisfaction with the clinical effects of HIFU in each area were similar regardless of the number of treatment shots. The jawline, cheek, and perioral areas were the sites where HIFU was most effective, in decreasing order. The adverse effects included erythema and swelling in six cases, and purpura and bruising in two cases. However, the adverse effects were mild and transient. HIFU could be a safe, effective, and noninvasive procedure that can be used to improve facial wrinkles and skin laxity in Asian skin. It is particularly effective for clinical improvement in the jawline, cheek, and perioral areas.

  11. Alterations in knee joint laxity during the menstrual cycle in healthy women leads to increases in joint loads during selected athletic movements.

    Science.gov (United States)

    Park, Sang-Kyoon; Stefanyshyn, Darren J; Ramage, Barbara; Hart, David A; Ronsky, Janet L

    2009-06-01

    It has been speculated that the hormonal cycle may be correlated with higher incidence of ACL injury in female athletes, but results have been very contradictory. Knee joint loads are influenced by knee joint laxity (KJL) during the menstrual cycle. Controlled laboratory study. Serum samples and KJL were assessed at the follicular, ovulation, and luteal phases in 26 women. Knee joint mechanics (angle, moment, and impulse) were measured and compared at the same intervals. Each of the 26 subjects had a value for knee laxity at each of the 3 phases of their cycle, and these were ordered and designated low, medium, and high for that subject. Knee joint mechanics were then compared between low, medium, and high laxity. No significant differences in knee joint mechanics were found across the menstrual cycle (no phase effect). However, an increase in KJL was associated with higher knee joint loads during movement (laxity effect). A 1.3-mm increase in KJL resulted in an increase of approximately 30% in adduction impulse in a cutting maneuver, an increase of approximately 20% in knee adduction moment, and a 20% to 45% increase in external rotation loads during a jumping and stopping task (P knee joint loading during movements. Clinical Relevance Our findings will be beneficial for researchers in the development of more effective ACL injury prevention programs.

  12. Evaluation of the safety and efficacy of a monopolar nonablative radiofrequency device for the improvement of vulvo-vaginal laxity and urinary incontinence.

    Science.gov (United States)

    Lalji, Shelena; Lozanova, Paula

    2017-06-01

    Vaginal childbirth, natural process of aging, congenital factors, and surgical interventions are considered the main causes of vulvo-vaginal laxity driven by changes in collagen and elastin fibers. This causes a loss of strength and flexibility within the vaginal wall. As a result, women may experience lack of sensation and stress urinary incontinence (SUI)-the condition of involuntary loss of urine associated with activities that cause an increase in intra-abdominal pressure (eg, sneezing, coughing, and lifting). Both vaginal laxity and urinary incontinence significantly affect patients' quality of life (QoL). The aim of this study was to evaluate efficacy and safety of a noninvasive radiofrequency device when used to treat SUI and vulvo-vaginal laxity through its heating effect which stimulates collagen and elastin fibers. Twenty-seven women (average age 44.78±10.04 years) with indications of mild/moderate SUI as well as vulvo-vaginal laxity were treated with a monopolar radiofrequency device. The treatment course consisted of three once-a-week sessions. Each session included intravaginal treatment followed by treatment of labia majora and the perineum. Improvement in the SUI condition was evaluated by applying the International Consultation on Incontinence Questionnaire - Urinary Incontinence Short Form (ICIQ-UI SF). Data were collected at the baseline, after the last treatment and at 1-month follow-up visit. Vaginal laxity was assessed by subjective vulvo-vaginal laxity questionnaire (VVLQ). Data were collected before the 1st treatment and during the 1-month follow-up visit. Patient's satisfaction was recorded using a satisfaction questionnaire. Data were collected after the last treatment and at the 1-month follow-up visit. Any adverse events related to the treatments were monitored. On a scale of 0 to 5, the average frequency of urine leak improved from "2-3 times a week" (2.15±1.03 points prior to treatment) to "once a week" (1.00±0.78 points post

  13. Increases in tibial force imbalance but not changes in tibiofemoral laxities are caused by varus-valgus malalignment of the femoral component in kinematically aligned TKA.

    Science.gov (United States)

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-01-29

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by 2° and 4° of varus-valgus (V-V) malalignment of the femoral component in kinematically aligned total knee arthroplasty (TKA) and use the results to detemine sensitivities to errors in making the distal femoral resections. Because V-V malalignment would introduce the greatest changes in the alignment of the articular surfaces at 0° flexion, the hypotheses were that the greatest increases in tibial force imbalance would occur at 0° flexion, that primarily V-V laxity would significantly change at this flexion angle, and that the tibial force imbalance would increase and laxities would change in proportion to the degree of V-V malalignment. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced V-V malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured during passive knee flexion-extension between 0° to 120° using a custom tibial force sensor. Eight laxities were measured from 0° to 120° flexion using a six degree-of-freedom load application system. With the tibial component kinematically aligned, the increase in the tibial force imbalance from that of the reference component at 0° of flexion was sensitive to the degree of V-V malalignment of the femoral component. Sensitivities were 54 N/deg (medial tibial force increasing > lateral tibial force) (p  medial tibial force) (p imbalance to increase significantly, whereas the laxities were relatively unaffected. Because tibial force imbalance has the potential to

  14. Spondylo-epi-metaphyseal dysplasia with joint laxity and severe, progressive kyphoscoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Beighton, P.; Kozlowski, K.

    1980-01-01

    Spondylo-epi-metaphyseal dysplasia with progressive, severe kyphoscoliosis and gross joint laxity is a distinctive entity. The clinical and radiographic manifestations of seven affected children are presented and it is concluded that this disorder is probably more common than previously suspected. Skeletal survey is indicated in all patients with infantile idiopathic scoliosis, kyphosis, or kyphoscoliosis. In this context, radiographic studies of the pelvis may be of great diagnostic value. Referal for expert orthopaedic management is essential for all patients with this disorder, as profound disability with pulmonary and spinal complications may be expected.

  15. Genome-Wide Identification of the Target Genes of AP2-O, a Plasmodium AP2-Family Transcription Factor.

    Directory of Open Access Journals (Sweden)

    Izumi Kaneko

    2015-05-01

    Full Text Available Stage-specific transcription is a fundamental biological process in the life cycle of the Plasmodium parasite. Proteins containing the AP2 DNA-binding domain are responsible for stage-specific transcriptional regulation and belong to the only known family of transcription factors in Plasmodium parasites. Comprehensive identification of their target genes will advance our understanding of the molecular basis of stage-specific transcriptional regulation and stage-specific parasite development. AP2-O is an AP2 family transcription factor that is expressed in the mosquito midgut-invading stage, called the ookinete, and is essential for normal morphogenesis of this stage. In this study, we identified the genome-wide target genes of AP2-O by chromatin immunoprecipitation-sequencing and elucidate how this AP2 family transcription factor contributes to the formation of this motile stage. The analysis revealed that AP2-O binds specifically to the upstream genomic regions of more than 500 genes, suggesting that approximately 10% of the parasite genome is directly regulated by AP2-O. These genes are involved in distinct biological processes such as morphogenesis, locomotion, midgut penetration, protection against mosquito immunity and preparation for subsequent oocyst development. This direct and global regulation by AP2-O provides a model for gene regulation in Plasmodium parasites and may explain how these parasites manage to control their complex life cycle using a small number of sequence-specific AP2 transcription factors.

  16. The development and validation of a custom built device for assessing frontal knee joint laxity.

    Science.gov (United States)

    Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos

    2017-12-01

    This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Curative effects of microneedle fractional radiofrequency system on skin laxity in Asian patients: A prospective, double-blind, randomized, controlled face-split study.

    Science.gov (United States)

    Lu, Wenli; Wu, Pinru; Zhang, Zhen; Chen, Jinan; Chen, Xiangdong; Ewelina, Biskup

    2017-04-01

    To date, no studies compared curative effects of thermal lesions in deep and superficial dermal layers in the same patient (face-split study). To evaluate skin laxity effects of microneedle fractional radiofrequency induced thermal lesions in different dermal layers. 13 patients underwent three sessions of a randomized face-split microneedle fractional radiofrequency system (MFRS) treatment of deep dermal and superficial dermal layer. Skin laxity changes were evaluated objectively (digital images, 2 independent experts) and subjectively (patients' satisfaction numerical rating). 12 of 13 subjects completed a course of 3 treatments and a 1-year follow-up. Improvement of nasolabial folds in deep dermal approach was significantly better than that in superficial approach at three months (P=.0002) and 12 months (P=.0057) follow-up. Effects on infraorbital rhytides were only slightly better (P=.3531). MFRS is an effective method to improve skin laxity. Thermal lesion approach seems to provide better outcomes when applied to deep dermal layers. It is necessary to consider the skin thickness of different facial regions when choosing the treatment depth.

  18. Resuspension of mild to moderate jawline laxity using a minimally invasive technique.

    Science.gov (United States)

    Bisaccia, Emil; Khan, Azim J; Herron, Joel B; Scarborough, Dwight A

    2003-08-01

    A practical approach for superficial musculoapponeurotic system plication and neck lift is indicated for early aging changes of jawline. A single or series of small punches or single incisions at the earlobe and then minor undermining to lift the superficial musculoapponeurotic system followed by removal of skin laxity in neck and jowl result in a seamless scar via a simple V to Y closure. A minimally invasive procedure was performed easily under local anesthesia in an office/ambulatory surgery center setting.

  19. Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding.

    Science.gov (United States)

    Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A; Swanik, Charles Buz; Kaminski, Thomas W

    2016-02-01

    Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Cross-sectional study. Research laboratory. Thirty-three participants aged 20.2 ± 1.7 years were tested. The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury.

  20. Methods to diagnose acute anterior cruciate ligament rupture: a meta-analysis of instrumented knee laxity tests

    NARCIS (Netherlands)

    van Eck, Carola F.; Loopik, Miette; van den Bekerom, Michel P.; Fu, Freddie H.; Kerkhoffs, Gino M. M. J.

    2013-01-01

    The aims of this meta-analysis were to determine the sensitivity and specificity of the KT 1000 Arthrometer, Stryker Knee Laxity Tester and Genucom Knee Analysis System for ACL rupture. It was hypothesized that the KT 1000 test is the most sensitive and specific. Secondly, it was hypothesized that

  1. Development of a superconducting undulator for the APS

    International Nuclear Information System (INIS)

    Ivanyushenkov, Y; Abliz, M; Doose, C; Fuerst, J; Hasse, Q; Kasa, M; Trakhtenberg, E; Vasserman, I; Gluskin, E; Lev, V; Mezentsev, N; Syrovatin, V; Tsukanov, V

    2013-01-01

    As the western hemisphere's premier x-ray synchrotron radiation source, the Advanced Photon Source (APS) continues to advance the state of the art in insertion device technology in order to maintain record high brightness, especially in the hard x-ray wavelength region. Due to the unique bunch pattern used for normal APS operations and its ultimate capabilities, the APS has chosen superconducting technology for its future hard x-ray undulator sources. In the last several years, the APS in collaboration with the Budker Institute of Nuclear Physics has being developing the technology for planar, small-period superconducting undulators (SCUs). These developments include the design and construction of several prototypes and the construction of the necessary mechanical, vacuum, and cryogenic infrastructure at the APS site. Several prototypes of the SCU magnetic structure have been built and tested. The first SCU is assembled and will be installed in the APS storage ring at the end of 2012. Expected SCU performance in terms of x-ray brightness should noticeably exceed that of existing APS undulators. Immediately after commissioning, the SCU will be used at APS Sector 6 as the radiation source for high-energy x-ray studies.

  2. Classification of Ap-stars HR 830 and ZI CVn

    International Nuclear Information System (INIS)

    Zverko, J.

    1984-01-01

    Two ambiguously classified Ap-stars, HR 830 and 21 CVn, are studied. The observational data are compared with the data for normal stars αDel and αLyr. Star HR 830 is classified as Ap of type Si based on the enhanced absorption in the Si lines and photometric variability in UBV. 21 CVn is classified as Ap Si based on weaker absorption of helium, the variability of helium lines, photometric periodic variability and the properties of the UV spectrum. It is concluded that the photometric periodic variability is a good indicator of Ap-properties of rapidly rotating A and late B stars. (author)

  3. Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations (I): catastrophic APS, APS nephropathy and heart valve lesions.

    Science.gov (United States)

    Cervera, R; Tektonidou, M G; Espinosa, G; Cabral, A R; González, E B; Erkan, D; Vadya, S; Adrogué, H E; Solomon, M; Zandman-Goddard, G; Shoenfeld, Y

    2011-02-01

    The objectives of the 'Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations' were to assess the clinical utility of the international consensus statement on classification criteria and treatment guidelines for the catastrophic APS, to identify and grade the studies that analyse the relationship between the antiphospholipid antibodies and the non-criteria APS manifestations and to present the current evidence regarding the accuracy of these non-criteria APS manifestations for the detection of patients with APS. This article summarizes the studies analysed on the catastrophic APS, APS nephropathy and heart valve lesions, and presents the recommendations elaborated by the Task Force after this analysis.

  4. Spondylo-epi-metaphyseal dysplasia with joint laxity and severe, progressive kyphoscoliosis

    International Nuclear Information System (INIS)

    Beighton, P.

    1980-01-01

    Spondylo-epi-metaphyseal dysplasia with progressive, severe kyphoscoliosis and gross joint laxity is a distinctive entity. The clinical and radiographic manifestations of seven affected children are presented and it is concluded that this order is probably more common than previously suspected. Skeletal survey is indicated in all patients with infantile idiopathic scoliosis, kyphosis, or kyphoscoliosis. In this context, radiographic studies of the pelvis may be of great diagnostic value. Referal for expert orhtopaedic management is essential for all patients with this disorder, as profound disability with pulmonary and spinal complications may be expected. (orig./MG) [de

  5. Bilaterally Asymmetric Effects of Quantitative Trait Loci (QTLs): QTLs That Affect Laxity in the Right Versus Left Coxofemoral (Hip) Joints of the Dog (Canis familiaris)

    OpenAIRE

    Chase, Kevin; Lawler, Dennis F.; Adler, Fred R.; Ostrander, Elaine A.; Lark, Karl G.

    2004-01-01

    In dogs hip joint laxity that can lead to degenerative joint disease (DJD) is frequent and heritable, providing a genetic model for some aspects of the human disease. We have used Portuguese water dogs (PWDs) to identify Quantitative trait loci (QTLs) that regulate laxity in the hip joint.A population of 286 PWDs, each characterized by ca. 500 molecular genetic markers, was analyzed for subluxation of the hip joint as measured by the Norberg angle, a quantitative radiographic measure of laxit...

  6. CGM ApS Årsberetning til DANAK

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    Denne årsberetning omfatter CGM ApS' akkrediterede virksomhed i kalenderåret 2003. Årsberetningen er udarbejdet til DANAK (Dansk Akkreditering, ErhvervsfremmeStyrelsen), som led i opfyldelsen af laboratoriets informationspligt i henhold til gældende regler.......Denne årsberetning omfatter CGM ApS' akkrediterede virksomhed i kalenderåret 2003. Årsberetningen er udarbejdet til DANAK (Dansk Akkreditering, ErhvervsfremmeStyrelsen), som led i opfyldelsen af laboratoriets informationspligt i henhold til gældende regler....

  7. Renal involvement in the antiphospholipid syndrome (APS)-APS nephropathy.

    Science.gov (United States)

    Tektonidou, Maria G

    2009-06-01

    Although the kidney represents a major target organ in antiphospholipid syndrome (APS), renal involvement in APS was poorly recognized until recently. The most well-recognized renal manifestations of APS are the renal artery thrombosis/stenosis, renal infarction, hypertension, renal vein thrombosis, end-stage renal disease, increased allograft vascular thrombosis, some types of glomerular disease, and a small-vessel vaso-occlusive nephropathy, recently defined as APS nephropathy. APS nephropathy was first described in primary APS patients, characterized by acute thrombotic lesions in glomeruli and/or arterioles (thrombotic microangiopathy) and chronic vascular lesions such as fibrous intimal hyperplasia of arterioles and interlobular arteries, organized thrombi with or without recanalization, and fibrous arterial and arteriolar occlusions or focal cortical atrophy. APS nephropathy was also detected in further studies including patients with systemic lupus erythematosus (SLE)-related APS and SLE/non-APS patients with positive antiphospholipid antibodies, independently of lupus nephritis. The same histologic lesions, especially thrombotic mictroangiopathy, were also observed in patients with catastrophic APS. The most frequent clinical and laboratory characteristics of APS nephropathy in all the above groups of patients are hypertension (often severe), proteinuria (ranging from mild to nephrotic range), hematuria, and acute or chronic renal insufficiency.

  8. Experimental study of 99Tcm-Ap4A in detection of atherosclerotic plaques

    International Nuclear Information System (INIS)

    Cao Wei; Zhang Yongxue; An Rui

    2001-01-01

    Objective: To study 99 Tc m labelled di-adenosine tetraphosphate (Ap4A), a compound can bind on P 2 purine receptors on atherosclerotic lesions, for imaging experimental atherosclerotic plaques in New Zealand White (NZW) rabbits. Methods: Twenty male NZW rabbits were submitted immune-injury and fed with high cholesterol diet for more than 2 months. To label the 99 Tc m to Ap4A, stannous tartrate solution was used. 99 Tc m -Ap4A was purified on a Sephadex G-25 column and tested for radiochemistry purity on thin layer chromatography. A biodistribution study was carried out on KM mice. Thirty minutes after intravenous injection of 7.4 MBq 99 Tc m -Ap4A, 5 normal NZW rabbits and 5 NZW rabbits with atherosclerotic lesions were sacrificed; their abdominal aortas were removed and covered with X-ray films. Exposed for 24 h in refrigerator, the films were developed and fixed. In another 5 NZW rabbits with atherosclerotic lesions, blood samples, atherosclerotic plaques and normal aortic wall samples were removed. Lesion to blood (target/blood, T/B), lesion to normal (target/non-target, T/NT) radioactivity ratios were calculated. 74 MBq 99 Tc m -Ap4A was injected into marginal ear veins of 5 atherosclerotic and 5 normal NZW rabbits. Simultaneously in vivo images were recorded for more than 4 h. In another group, 30 min after 99 Tc m -Ap4A administration, the animals were sacrificed and their abdominal aortas were removed. The abdominal aortas were placed on the face of SPECT and images acquisition was performed. Results: The radiochemistry purity of 99 Tc m -Ap4A was 85% to 91%. Biodistribution study revealed the clearance of 99 Tc m -Ap4A from blood was rapid. Thirty min after 99 Tc m -Ap4A administration, T/B radio was 3.17 +- 1.27, T/NT ratio was 5.23 +- 1.87. On the radioautography film shadows of atherosclerotic plaques were clearly visible. The atherosclerotic plaques on the aorta samples also can be seen on ex vivo images. Atherosclerotic abdominal aortas and lesions

  9. Radiographic features of spondylo-epimetaphyseal dysplasia with joint laxity and progressive kyphoscoliosis

    International Nuclear Information System (INIS)

    Kozlowski, K.; Beighton, P.

    1984-01-01

    We have reviewed the radiographic features of 19 patients with spondyloepimetaphyseal dysplasia with joint laxity (SEMDJL). The salient, diagnostic radiographic manifestations are mild to moderate spondylo-epimetaphyseal dysplasia, progressive infantile kyphoscoliosis, characteristic pelvic, forearm and elbow changes and a highly abnormal bony trabecular pattern. The condition, which is inherited as an autosomal recessive, has only been observed in South Africa among Caucasians, several of whom have German names or German connections. The authors wish to bring the condition to the attention of European radiologists in an attempt to determine the geographic origin of the faulty gene. (orig.) [de

  10. Effect of thread embedding acupuncture for facial wrinkles and laxity: a single-arm, prospective, open-label study

    Directory of Open Access Journals (Sweden)

    Younghee Yun

    2017-12-01

    Full Text Available Background: There is a growing trend for patients to seek the least invasive treatments with less risk of complications and downtime for facial rejuvenation. Thread embedding acupuncture has become popular as a minimally invasive treatment. However, there is little clinical evidence in the literature regarding its effects. Methods: This single-arm, prospective, open-label study recruited participants who were women aged 40–59 years, with Glogau photoaging scale III–IV. Fourteen participants received thread embedding acupuncture one time and were measured before and after 1 week from the procedure. The primary outcome was a jowl to subnasale vertical distance. The secondary outcomes were facial wrinkle distances, global esthetic improvement scale, Alexiades–Armenakas laxity scale, and patient-oriented self-assessment scale. Results: Fourteen participants underwent thread embedding acupuncture alone, and 12 participants revisited for follow-up outcome measures. For the primary outcome measure, both jowls were elevated in vertical height by 1.87 mm (left and 1.43 mm (right. Distances of both melolabial and nasolabial folds showed significant improvement. In the Alexiades–Armenakas laxity scale, each evaluator evaluated for four and nine participants by 0.5 grades improved. In the global aesthetic improvement scale, improvement was graded as 1 and 2 in nine and five cases, respectively. The most common adverse events were mild bruising, swelling, and pain. However, adverse events occurred, although mostly minor and of short duration. Conclusion: In this study, thread embedding acupuncture showed clinical potential for facial wrinkles and laxity. However, further large-scale trials with a controlled design and objective measurements are needed. Keywords: polydioxanone, rejuvenation, rhytidoplasty, skin aging, thread embedding acupuncture

  11. Assessment of knee laxity using a robotic testing device: a comparison to the manual clinical knee examination.

    Science.gov (United States)

    Branch, T P; Stinton, S K; Siebold, R; Freedberg, H I; Jacobs, C A; Hutton, W C

    2017-08-01

    The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7° larger valgus angle, 3° greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/°) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.

  12. Internal-external malalignment of the femoral component in kinematically aligned total knee arthroplasty increases tibial force imbalance but does not change laxities of the tibiofemoral joint.

    Science.gov (United States)

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by  2° and 4° of internal-external (I-E) malalignment of the femoral component in kinematically aligned total knee arthroplasty. Because I-E malalignment would introduce the greatest changes to the articular surfaces near 90° of flexion, the hypotheses were that the tibial force imbalance would be significantly increased near 90° flexion and that primarily varus-valgus laxity would be affected near 90° flexion. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced I-E malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured from 0° to 120° flexion using a custom tibial force sensor. Bidirectional laxities in four degrees of freedom were measured from 0° to 120° flexion using a custom load application system. Tibial force imbalance increased the greatest at 60° flexion where a regression analysis against the degree of I-E malalignment yielded sensitivities (i.e. slopes) of 30 N/° (medial tibial force > lateral tibial force) and 10 N/° (lateral tibial force > medial tibial force) for internal and external malalignments, respectively. Valgus laxity increased significantly with the 4° external component with the greatest increase of 1.5° occurring at 90° flexion (p < 0.0001). With the tibial component correctly aligned, I-E malalignment of the femoral component caused significant increases in tibial force imbalance. Minimizing I-E malalignment lowers the increase in the tibial force imbalance. By keeping

  13. Fractional CO2 laser treatment for vaginal laxity: A preclinical study.

    Science.gov (United States)

    Kwon, Tae-Rin; Kim, Jong Hwan; Seok, Joon; Kim, Jae Min; Bak, Dong-Ho; Choi, Mi-Ji; Mun, Seok Kyun; Kim, Chan Woong; Ahn, Seungwon; Kim, Beom Joon

    2018-05-07

    Various studies have investigated treatment for vaginal laxity with microablative fractional carbon dioxide CO 2 laser in humans; however, this treatment has not yet been studied in an animal model. Herein, we evaluate the therapeutic effects of fractional CO 2 laser for tissue remodeling of vaginal mucosa using a porcine model, with the aim of improving vaginal laxity. The fractional CO 2 laser enables minimally invasive and non-incisional procedures. By precisely controlling the laser energy pulses, energy is sent to the vaginal canal and the introitus area to induce thermal denaturation and contraction of collagen. We examined the effects of fractional CO 2 laser on a porcine model via clinical observation and ultrasound measurement. Also, thermal lesions were histologically examined via hematoxylin-eosin staining, Masson's trichrome staining, and Elastica van Gieson staining and immunohistochemistry. The three treatment groups, which were determined according to the amount of laser-energy applied (60, 90, and 120 mJ), showed slight thermal denaturation in the vaginal mucosa, but no abnormal reactions, such as excessive hemorrhaging, vesicles, or erythema, were observed. Histologically, we also confirmed that the denatured lamina propria induced by fractional CO 2 laser was dose-dependently increased after laser treatment. The treatment groups also showed an increase in collagen and elastic fibers due to neocollagenesis and angiogenesis, and the vaginal walls became firmer and tighter because of increased capillary and vessel formation. Also, use of the fractional CO 2 laser increased HSP (heat shock protein) 70 and collagen type I synthesis. Our results show that microablative fractional CO 2 laser can produce remodeling of the vaginal connective tissue without causing damage to surrounding tissue, and the process of mucosa remodeling while under wound dressings enables collagen to increase and the vaginal wall to become thick and tightened. Lasers Surg. Med

  14. A Combined Experimental and Computational Approach to Subject-Specific Analysis of Knee Joint Laxity

    Science.gov (United States)

    Harris, Michael D.; Cyr, Adam J.; Ali, Azhar A.; Fitzpatrick, Clare K.; Rullkoetter, Paul J.; Maletsky, Lorin P.; Shelburne, Kevin B.

    2016-01-01

    Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community. PMID:27306137

  15. Transcription factor AP-2gamma is a developmentally regulated marker of testicular carcinoma in situ and germ cell tumors

    DEFF Research Database (Denmark)

    Hoei-Hansen, Christina E; Nielsen, John E; Almstrup, Kristian

    2004-01-01

    and protein level in normal human tissues and a panel of tumors and tumor-derived cell lines. In the gonads, we established the ontogeny of expression of AP-2gamma in normal and dysgenetic samples. We also investigated the regulation of AP-2gamma by steroids and retinoic acid. RESULTS: We detected abundant AP...

  16. Dwarfism with joint laxity in Friesian horses is associated with a splice site mutation in B4GALT7.

    Science.gov (United States)

    Leegwater, Peter A; Vos-Loohuis, Manon; Ducro, Bart J; Boegheim, Iris J; van Steenbeek, Frank G; Nijman, Isaac J; Monroe, Glen R; Bastiaansen, John W M; Dibbits, Bert W; van de Goor, Leanne H; Hellinga, Ids; Back, Willem; Schurink, Anouk

    2016-10-28

    Inbreeding and population bottlenecks in the ancestry of Friesian horses has led to health issues such as dwarfism. The limbs of dwarfs are short and the ribs are protruding inwards at the costochondral junction, while the head and back appear normal. A striking feature of the condition is the flexor tendon laxity that leads to hyperextension of the fetlock joints. The growth plates of dwarfs display disorganized and thickened chondrocyte columns. The aim of this study was to identify the gene defect that causes the recessively inherited trait in Friesian horses to understand the disease process at the molecular level. We have localized the genetic cause of the dwarfism phenotype by a genome wide approach to a 3 Mb region on the p-arm of equine chromosome 14. The DNA of two dwarfs and one control Friesian horse was sequenced completely and we identified the missense mutation ECA14:g.4535550C > T that cosegregated with the phenotype in all Friesians analyzed. The mutation leads to the amino acid substitution p.(Arg17Lys) of xylosylprotein beta 1,4-galactosyltransferase 7 encoded by B4GALT7. The protein is one of the enzymes that synthesize the tetrasaccharide linker between protein and glycosaminoglycan moieties of proteoglycans of the extracellular matrix. The mutation not only affects a conserved arginine codon but also the last nucleotide of the first exon of the gene and we show that it impedes splicing of the primary transcript in cultured fibroblasts from a heterozygous horse. As a result, the level of B4GALT7 mRNA in fibroblasts from a dwarf is only 2 % compared to normal levels. Mutations in B4GALT7 in humans are associated with Ehlers-Danlos syndrome progeroid type 1 and Larsen of Reunion Island syndrome. Growth retardation and ligamentous laxity are common manifestations of these syndromes. We suggest that the identified mutation of equine B4GALT7 leads to the typical dwarfism phenotype in Friesian horses due to deficient splicing of transcripts of

  17. Roles of AP-2 in clathrin-mediated endocytosis.

    Directory of Open Access Journals (Sweden)

    Emmanuel Boucrot

    2010-05-01

    Full Text Available The notion that AP-2 clathrin adaptor is an essential component of an endocytic clathrin coat appears to conflict with recent observations that substantial AP-2 depletion, using RNA interference with synthesis of AP-2 subunits, fails to block uptake of certain ligands known to internalize through a clathrin-based pathway.We report here the use of in vivo imaging data obtained by spinning-disk confocal microscopy to study the formation of clathrin-coated structures at the plasma membranes of BSC1 and HeLa cells depleted by RNAi of the clathrin adaptor, AP-2. Very few clathrin coats continue to assemble after AP-2 knockdown. Moreover, there is a total absence of clathrin-containing structures completely lacking AP-2 while all the remaining coats still contain a small amount of AP-2. These observations suggest that AP-2 is essential for endocytic coated-pit and coated-vesicle formation. We also find that AP-2 knockdown strongly inhibits light-density lipoprotein (LDL receptor-mediated endocytosis, as long as cells are maintained in complete serum and at 37 degrees C. If cells are first incubated with LDL at 4 degrees C, followed by warming, there is little or no decrease in LDL uptake with respect to control cells. LDL uptake at 37 degrees C is also not affected in AP-2 depleted cells first deprived of LDL by incubation with either serum-starved or LDL-starved cells for 24 hr. The LDL-deprived cells display a significant increase in endocytic structures enriched on deeply invaginated tubes that contain LDL and we suggest that under this condition of stress, LDL might enter through this alternative pathway.These results suggest that AP-2 is essential for endocytic clathrin coated-pit and coated-vesicle formation. They also indicate that under normal conditions, functional endocytic clathrin coated pits are required for LDL internalization. We also show that under certain conditions of stress, cells can upregulate alternative endocytic structures

  18. Center for Geometrisk Metrologi, CGM ApS

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    Denne årsberetning omfatter CGM ApS' akkrediterede virksomhed i kalenderåret 2002. Årsberetningen er udarbejdet til DANAK (Dansk Akkreditering, Erhvervsfremme Styrelsen), som led i opfyldelsen af laboratoriets informationspligt i henhold til gældende regler (Teknisk Forskrift Nr. TF4 af 2000...

  19. Tank 241-AP-106, Grab samples, 6AP-98-1, 6AP-98-2 and 6AP-98-3 Analytical results for the final report

    Energy Technology Data Exchange (ETDEWEB)

    FULLER, R.K.

    1999-02-23

    This document is the final report for tank 241-AP-106 grab samples. Three grab samples 6AP-98-1, 6AP-98-2 and 6AP-98-3 were taken from riser 1 of tank 241-AP-106 on May 28, 1998 and received by the 222-S Laboratory on May 28, 1998. Analyses were performed in accordance with the ''Compatability Grab Sampling and Analysis Plan'' (TSAP) (Sasaki, 1998) and the ''Data Quality Objectives for Tank Farms Waste Compatability Program (DQO). The analytical results are presented in the data summary report. No notification limits were exceeded. The request for sample analysis received for AP-106 indicated that the samples were polychlorinated biphenyl (PCB) suspects. The results of this analysis indicated that no PCBs were present at the Toxic Substance Control Act (TSCA) regulated limit of 50 ppm. The results and raw data for the PCB analysis are included in this document.

  20. Tank 241-AP-106, Grab samples, 6AP-98-1, 6AP-98-2 and 6AP-98-3 Analytical results for the final report

    International Nuclear Information System (INIS)

    FULLER, R.K.

    1999-01-01

    This document is the final report for tank 241-AP-106 grab samples. Three grab samples 6AP-98-1, 6AP-98-2 and 6AP-98-3 were taken from riser 1 of tank 241-AP-106 on May 28, 1998 and received by the 222-S Laboratory on May 28, 1998. Analyses were performed in accordance with the ''Compatability Grab Sampling and Analysis Plan'' (TSAP) (Sasaki, 1998) and the ''Data Quality Objectives for Tank Farms Waste Compatability Program (DQO). The analytical results are presented in the data summary report. No notification limits were exceeded. The request for sample analysis received for AP-106 indicated that the samples were polychlorinated biphenyl (PCB) suspects. The results of this analysis indicated that no PCBs were present at the Toxic Substance Control Act (TSCA) regulated limit of 50 ppm. The results and raw data for the PCB analysis are included in this document

  1. AP@home: The Artificial Pancreas Is Now at Home.

    Science.gov (United States)

    Heinemann, Lutz; Benesch, Carsten; DeVries, J Hans

    2016-07-01

    In the past years the development of an artificial pancreas (AP) has made great progress and many activities are ongoing in this area of research. The major step forward made in the last years was moving the evaluation of AP systems from highly controlled experimental conditions to daily life conditions at the home of patients with diabetes; this was also the aim of the European Union-funded AP@home project. Over a time period of 5 years a series of clinical studies were performed that culminated in 2 "final studies" during which an AP system was used by patients in their home environment for 2 or 3 months without supervision by a physician, living their normal lives. Two different versions of the AP system developed within this project were evaluated. A significant improvement in glycated hemoglobin was observed during closed-loop conditions despite the fact that during the control period the patients used the best currently available therapeutic option. In addition, a "single-port AP system" was developed within the project that combines continuous glucose monitoring and insulin infusion at a single tissue site. By using such a combined device the patients not only have to carry one less device around, the number of access points through the skin is also reduced from 2 to 1. In summary, close cooperation of 12 European partners, both academic centers and industry, enabled the development and evaluation of AP systems under daily life conditions. The next step is to develop these into products in cooperation with commercial partners. © 2016 Diabetes Technology Society.

  2. Thrombotic risk assessment in APS: the Global APS Score (GAPSS).

    Science.gov (United States)

    Sciascia, S; Bertolaccini, M L

    2014-10-01

    Recently, we developed a risk score for antiphospholipid syndrome (APS) (Global APS Score or GAPSS). This score derived from the combination of independent risk factors for thrombosis and pregnancy loss, taking into account the antiphospholipid antibodies (aPL) profile (criteria and non-criteria aPL), the conventional cardiovascular risk factors, and the autoimmune antibodies profile. We demonstrate that risk profile in APS can be successfully assessed, suggesting that GAPSS can be a potential quantitative marker of APS-related clinical manifestations. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Antiphospholipid syndrome (APS) nephropathy in catastrophic, primary, and systemic lupus erythematosus-related APS.

    Science.gov (United States)

    Tektonidou, Maria G; Sotsiou, Flora; Moutsopoulos, Haralampos M

    2008-10-01

    Renal involvement in antiphospholipid syndrome (APS) has been poorly recognized. A renal small-vessel vasculopathy, defined as APS nephropathy, has recently been observed in small series of patients with primary APS (PAPS) and systemic lupus erythematosus (SLE)-APS. We examined the renal histologic, clinical, and laboratory characteristics of different groups of patients with APS including catastrophic APS (CAPS). Our study included all CAPS (n=6), PAPS (n=8), and SLE-APS (n=23) patients with biopsy-proven renal involvement who were referred to our departments. The kidney biopsy specimens were retrospectively examined by the same renal pathologist. APS nephropathy was diagnosed as previously described. Demographic, clinical, and laboratory data were recorded. All patients with CAPS had acute and chronic renal vascular lesions compatible with diagnosis of APS nephropathy. Thrombotic microangiopathy (TMA), the acute lesion, was observed in all CAPS patients. Fibrous intimal hyperplasia of interlobular arteries (FIH) and focal cortical atrophy (FCA) were the most common chronic vascular lesions, occurring in 4 of 6 (66.7%) and 3 of 6 (50%) patients with CAPS, respectively. TMA was detected in 3 of 8 (37.5%) patients with PAPS and in 8 of 23 (35%) patients with SLE-APS, while FIH and FCA were found with similar frequencies in all 3 groups. Hypertension, proteinuria, hematuria, and renal insufficiency were the most common renal manifestations of all APS groups. Acute and chronic APS nephropathy lesions were detected in all 3 APS groups. Acute lesions were more prominent in CAPS, while chronic lesions were found with similar frequencies in all groups. Hypertension, proteinuria, hematuria, and renal insufficiency were the most common renal manifestations of all APS groups.

  4. AP600 containment purge radiological analysis

    Energy Technology Data Exchange (ETDEWEB)

    O`Connor, M.; Schulz, J.; Tan, C. [Bechtel Power Corporation (United States)] [and others

    1995-02-01

    The AP600 Project is a passive pressurized water reactor power plant which is part of the Design Certification and First-of-a-Kind Engineering effort under the Advanced Light Water Reactor program. Included in this process is the design of the containment air filtration system which will be the subject of this paper. We will compare the practice used by previous plants with the AP600 approach to meet the goals of industry standards in sizing the containment air filtration system. The radiological aspects of design are of primary significance and will be the focus of this paper. The AP600 Project optimized the design to combine the functions of the high volumetric flow rate, low volumetric flow rate, and containment cleanup and other filtration systems into one multi-functional system. This achieves a more simplified, standardized, and lower cost design. Studies were performed to determine the possible concentrations of radioactive material in the containment atmosphere and the effectiveness of the purge system to keep concentrations within 10CFR20 limits and within offsite dose objectives. The concentrations were determined for various reactor coolant system leakage rates and containment purge modes of operation. The resultant concentrations were used to determine the containment accessibility during various stages of normal plant operation including refueling. The results of the parametric studies indicate that a dual train purge system with a capacity of 4,000 cfm per train is more than adequate to control the airborne radioactivity levels inside containment during normal plant operation and refueling, and satisfies the goals of ANSI/ANS-56.6-1986 and limits the amount of radioactive material released to the environment per ANSI/ANS 59.2-1985 to provide a safe environment for plant personnel and offsite residents.

  5. APS Science 2006

    International Nuclear Information System (INIS)

    Gibson, J.M.; Fenner, R.B.; Long, G.; Borland, M.; Decker, G.

    2007-01-01

    In my five years as the Director of the Advanced Photon Source (APS), I have been fortunate to see major growth in the scientific impact from the APS. This year I am particularly enthusiastic about prospects for our longer-term future. Every scientific instrument must remain at the cutting edge to flourish. Our plans for the next generation of APS--an APS upgrade--got seriously in gear this year with strong encouragement from our users and sponsors. The most promising avenue that has emerged is the energy-recovery linac (ERL) (see article on page xx), for which we are beginning serious R and D. The ERL(at)APS would offer revolutionary performance, especially for x-ray imaging and ultrafast science, while not seriously disrupting the existing user base. I am very proud of our accelerator physics and engineering staff, who not only keep the current APS at the forefront, but were able to greatly impress our international Machine Advisory Committee with the quality of their work on the possible upgrade option (see page xx). As we prepare for long-term major upgrades, our plans to develop and optimize all the sectors at APS in the near future are advancing. Several new beamlines saw first light this year, including a dedicated powder diffraction beamline (11-BM), two instruments for inelastic x-ray scattering at sector 30, and the Center for Nanoscale Materials (CNM) Nanoprobe beamline at sector 26. Our partnership in the first x-ray free-electron laser (LCLS) to be built at Stanford contributes to revolutionary growth in ultrafast science (see page xx), and we are developing a pulse chirping scheme to get ps pulses at sector 7 of the APS within a year or so. In this report, you will find selected highlights of scientific research at the APS from calendar year 2006. The highlighted work covers diverse disciplines, from fundamental to applied science. In the article on page xx you can see the direct impact of APS research on technology. Several new products have emerged

  6. APS Science 2006.

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, J. M.; Fenner, R. B.; Long, G.; Borland, M.; Decker, G.

    2007-05-24

    In my five years as the Director of the Advanced Photon Source (APS), I have been fortunate to see major growth in the scientific impact from the APS. This year I am particularly enthusiastic about prospects for our longer-term future. Every scientific instrument must remain at the cutting edge to flourish. Our plans for the next generation of APS--an APS upgrade--got seriously in gear this year with strong encouragement from our users and sponsors. The most promising avenue that has emerged is the energy-recovery linac (ERL) (see article on page xx), for which we are beginning serious R&D. The ERL{at}APS would offer revolutionary performance, especially for x-ray imaging and ultrafast science, while not seriously disrupting the existing user base. I am very proud of our accelerator physics and engineering staff, who not only keep the current APS at the forefront, but were able to greatly impress our international Machine Advisory Committee with the quality of their work on the possible upgrade option (see page xx). As we prepare for long-term major upgrades, our plans to develop and optimize all the sectors at APS in the near future are advancing. Several new beamlines saw first light this year, including a dedicated powder diffraction beamline (11-BM), two instruments for inelastic x-ray scattering at sector 30, and the Center for Nanoscale Materials (CNM) Nanoprobe beamline at sector 26. Our partnership in the first x-ray free-electron laser (LCLS) to be built at Stanford contributes to revolutionary growth in ultrafast science (see page xx), and we are developing a pulse chirping scheme to get ps pulses at sector 7 of the APS within a year or so. In this report, you will find selected highlights of scientific research at the APS from calendar year 2006. The highlighted work covers diverse disciplines, from fundamental to applied science. In the article on page xx you can see the direct impact of APS research on technology. Several new products have emerged from

  7. Imaging of posterior cruciate ligament (PCL) reconstruction: normal postsurgical appearance and complications

    Energy Technology Data Exchange (ETDEWEB)

    Alcala-Galiano, Andrea; Baeva, Maria; Jose Argueeso, Maria [Hospital ASEPEYO Coslada, Department of Radiology, Madrid (Spain); Ismael, Maryem [Hospital ASEPEYO Coslada, Department of Traumatology and Orthopaedic Surgery, Madrid (Spain)

    2014-12-15

    This article reviews the normal postsurgical anatomy and appearance of PCL reconstructions on MDCT and MRI with the different operative techniques considering the type of tibial fixation, use of a single or double bundle, type of tendon graft and the fixation material. Tunnel positioning, appearance of the ligament graft and findings at the donor site are considered. Imaging signs of PCL graft failure and its possible causes are discussed. Imaging manifestations of other potential complications of both the PCL graft and donor sites are described, such as laxity, impingement, arthrofibrosis, ganglion cyst formation or complications related to the fixation material. (orig.)

  8. Lobular carcinoma in situ and invasive lobular breast cancer are characterized by enhanced expression of transcription factor AP-2β.

    Science.gov (United States)

    Raap, Mieke; Gronewold, Malte; Christgen, Henriette; Glage, Silke; Bentires-Alj, Mohammad; Koren, Shany; Derksen, Patrick W; Boelens, Mirjam; Jonkers, Jos; Lehmann, Ulrich; Feuerhake, Friedrich; Kuehnle, Elna; Gluz, Oleg; Kates, Ronald; Nitz, Ulrike; Harbeck, Nadia; Kreipe, Hans H; Christgen, Matthias

    2018-01-01

    Transcription factor AP-2β (TFAP2B) regulates embryonic organ development and is overexpressed in alveolar rhabdomyosarcoma, a rare childhood malignancy. Gene expression profiling has implicated AP-2β in breast cancer (BC). This study characterizes AP-2β expression in the mammary gland and in BC. AP-2β protein expression was assessed in the normal mammary gland epithelium, in various reactive, metaplastic and pre-invasive neoplastic lesions and in two clinical BC cohorts comprising >2000 patients. BCs from various genetically engineered mouse (GEM) models were also evaluated. Human BC cell lines served as functional models to study siRNA-mediated inhibition of AP-2β. The normal mammary gland epithelium showed scattered AP-2β-positive cells in the luminal cell layer. Various reactive and pre-invasive neoplastic lesions, including apocrine metaplasia, usual ductal hyperplasia and lobular carcinoma in situ (LCIS) showed enhanced AP-2β expression. Cases of ductal carcinoma in situ (DCIS) were more often AP-2β-negative (Pinvasive BC cohorts, AP-2β-positivity was associated with the lobular BC subtype (Plobular BC cell lines in vitro. In summary, AP-2β is a new mammary epithelial differentiation marker. Its expression is preferentially retained and enhanced in LCIS and invasive lobular BC and has prognostic implications. Our findings indicate that AP-2β controls tumor cell proliferation in this slow-growing BC subtype.

  9. BPM STABILTIY STUDIES FOR THE APS MBA UPGRADE

    Energy Technology Data Exchange (ETDEWEB)

    Lill, R.; Sereno, N.; Yang, B.

    2017-03-25

    The Advanced Photon Source (APS) is currently in the preliminary design phase for the multi-bend achromat (MBA) lattice upgrade. Beam stability is critical for the MBA and will require long term drift defined as beam mo-tion over a seven-day timescale to be no more than 1 mi-cron at the insertion device locations and beam angle change no more than 0.25 micro-radian. Mechanical stabil-ity of beam position monitor (BPM) pickup electrodes mounted on insertion device vacuum chambers place a fun-damental limitation on long-term beam stability for inser-tion device beamlines. We present the design and imple-mentation of prototype mechanical motion system (MMS) instrumentation for quantifying this type of motion specif-ically in the APS accelerator tunnel and experiment hall floor under normal operating conditions. The MMS pres-ently provides critical position information on the vacuum chamber and BPM support systems. Initial results of the R&D prototype systems have demonstrated that the cham-ber movements far exceed the long-term drift tolerance specified for the APS Upgrade MBA storage ring.

  10. Testing of Solar Heated Domestic Hot Water System for Solahart Scandinavia ApS

    DEFF Research Database (Denmark)

    Andersen, Elsa

    1997-01-01

    The solar heating system marketed by Solahart Scandinavia ApS was tested in the Institutes test facility for SDHWsystems. The test results are described in the report.......The solar heating system marketed by Solahart Scandinavia ApS was tested in the Institutes test facility for SDHWsystems. The test results are described in the report....

  11. Got AP?

    Science.gov (United States)

    Digby, Joan

    2016-01-01

    Families, especially those considering sending their children to a private four-year university, need all the help they can get in funding college. Annmarie Guzy's essay "AP, Dual Enrollment, and the Survival of Honors Education" in this issue powerfully spells out the financial benefits that accrue from using AP courses to satisfy…

  12. Westinghouse AP1000 licensing maturity

    International Nuclear Information System (INIS)

    Schulz, T.; Vijuk, R.P.

    2005-01-01

    The Westinghouse AP1000 Program is aimed at making available a nuclear power plant that is economical in the U.S deregulated electrical power industry in the near-term. The AP1000 is two-loop 1000 MWe pressurizer water reactor (PWR). It is an up rated version of the AP600. The AP1000 uses passive safety systems to provide significant and measurable improvements in plant simplification, safety, reliability, investment protection and plant costs. The AP1000 uses proven technology, which builds on over 35 years of operating PWR experience. The AP1000 received Final Design Approval by the United States Nuclear Regulatory Commission (U.S. NRC) in September 2004. The AP1000 meets the US utility requirements. The AP1000 and its sister plant the AP600 have gone through a very through and complete licensing review. This paper describes the U.S. NRC review efforts of both the AP600 and the AP1000. The detail of the review and the independent calculations, evaluations and testing is discussed. The AP600 licensing documentation was submitted in 1992. The U.S. NRC granted Final Design Approval in 1999. During the intervening 7 years, the U.S. NRC asked thousands of questions, performed independent safety analysis, audited Westinghouse calculations and analysis, and performed independent testing. The more significant areas of discussion will be described. For the AP1000 Westinghouse first engaged the U.S. NRC in pre-certification discussions to define the extent of the review required, since the design is so similar to the AP600. The AP1000 licensing documentation was submitted in March 2002. The U.S. NRC granted Final Design Approval in September 2004. During the intervening 2 1/2 years, the U.S. NRC asked hundreds of questions, performed independent safety analysis, audited Westinghouse calculations and analysis, and performed independent testing. The more significant areas of discussion will be described. The implications of this review and approval on AP1000 applications in

  13. APS Science 2009.

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, J. M; Mills, D. M.; Gerig, R.

    2010-05-01

    It is my pleasure to introduce the 2009 annual report of the Advanced Photon Source. This was a very good year for us. We operated with high reliability and availability, despite growing problems with obsolete systems, and our users produced a record output of publications. The number of user experiments increased by 14% from 2008 to more than 3600. We congratulate the recipients of the 2009 Nobel Prize in Chemistry-Venkatraman Ramakrishnan (Cambridge Institute for Medical Research), Thomas Steitz (Yale University), and Ada Yonath (Weizmann Institute) - who did a substantial amount of this work at APS beamlines. Thanks to the efforts of our users and staff, and the ongoing counsel of the APS Scientific Advisory Committee, we made major progress in advancing our planning for the upgrade of the APS (APS-U), producing a proposal that was positively reviewed. We hope to get formal approval in 2010 to begin the upgrade. With advocacy from our users and the support of our sponsor, the Office of Basic Energy Sciences in the Department of Energy (DOE) Office of Science, our operating budgets have grown to the level needed to more adequately staff our beamlines. We were also extremely fortunate to have received $7.9 M in American Recovery and Reinvestment Act ('stimulus') funding to acquire new detectors and improve several of our beamlines. The success of the new Linac Coherent Light Source at Stanford, the world's first x-ray free-electron laser, made us particularly proud since the undulators were designed and built by the APS. Among other highlights, we note that more than one-quarter of the 46 Energy Frontier Research Centers, funded competitively across the U.S. in 2009 by the DOE, included the Advanced Photon Source in their proposed work, which shows that synchrotron radiation, and the APS in particular, are central to energy research. While APS research covers everything from fundamental to applied science (reflected by the highlights in this report

  14. Radiation measurements during cavities conditioning on APS RF test stand

    International Nuclear Information System (INIS)

    Grudzien, D.M.; Kustom, R.L.; Moe, H.J.; Song, J.J.

    1993-01-01

    In order to determine the shielding structure around the Advanced Photon Source (APS) synchrotron and storage ring RF stations, the X-ray radiation has been measured in the near field and far field regions of the RF cavities during the normal conditioning process. Two cavity types, a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity, are used on the APS and are conditioned in the RF test stand. Vacuum measurements are also taken on a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity. The data will be compared with data on the five-cell cavities from CERN

  15. Westinghouse AP1000® PWR: Meeting Customer Commitments and Market Needs

    International Nuclear Information System (INIS)

    Shulyak, Nick

    2014-01-01

    Westinghouse Electric Company once again sets a new industry standard with the AP1000 reactor. Historically, Westinghouse plant designs and technology have forged the cutting edge of worldwide nuclear technology. Today, about 50 percent of the world's 440 nuclear plants are based on Westinghouse technology. The AP1000 is the safest and most economical nuclear power plant available in the worldwide commercial marketplace, and is the only Generation III+ reactor to receive Design Certification from the U.S. Nuclear Regulatory Commission (NRC). The AP1000 features proven technology, innovative passive safety systems and offers: Unequalled safety, Economic competitiveness, Improved and more efficient operations. The AP1000 builds and improves upon the established technology of major components used in current Westinghouse-designed plants with proven, reliable operating experience over the past 50 years. These components include: Steam generators, Digital instrumentation and controls, Fuel, Pressurizers, Reactor vessels. Simplification was a major design objective for the AP1000. The simplified plant design includes overall safely systems, normal operating systems, the control room, construction techniques, and instrumentation and control systems. The result is a plant that is easier and less expensive to build, operate and maintain. The AP1000 design saves money and time with an accelerated construction time period of approximately 36 months, from the pouring of first concrete to the loading of fuel. Also, the innovative AP1000 features: 50% fewer safety-related valves, 80% less safety-related piping, 85% less control cable, 35% fewer pumps , 45% less seismic building volume. Eight AP1000 units under construction worldwide-Four units in China-Four units in the United States. (author)

  16. Vascular Manifestations in Antiphospholipid Syndrome (APS): Is APS a Thrombophilia or a Vasculopathy?

    Science.gov (United States)

    Siddique, Salma; Risse, Jessie; Canaud, Guillaume; Zuily, Stéphane

    2017-09-04

    Antiphospholipid antibody syndrome (APS) is characterized primarily by thrombosis and pregnancy morbidity. Chronic vascular lesions can also occur. While the underlying mechanisms of these vascular lesions are not entirely known, there have been multiple theories describing the potential process of vasculopathy in APS and the various clinical manifestations associated with it. Recently, it has been demonstrated that endothelial proliferation in kidneys can be explained by the activation of the mammalian target of rapamycin complex (mTORC) pathway by antiphospholipid antibodies (aPL). These data support the existence of an APS-related vasculopathy in different locations which can explain-in part-the different manifestations of APS. This review focuses on the various manifestations of APS as a result of APS-related vasculopathy, as well as pathophysiology, current screening, and treatment options for clinicians to be aware of.

  17. Kepler observations of rapidly oscillating Ap, δ Scuti and γ Doradus pulsations in Ap stars

    DEFF Research Database (Denmark)

    Balona, Luis A.; Cunha, Margarida S.; Kurtz, Donald W.

    2011-01-01

    Observations of the A5p star KIC 8677585 obtained during the Kepler 10-d commissioning run with 1-min time resolution show that it is a rapidly oscillating Ap (roAp) star with several frequencies with periods near 10 min. In addition, a low frequency at 3.142 d−1 is also clearly present....... Multiperiodic γ Doradus (γ Dor) and δ Scuti (δ Sct) pulsations, never before seen in any Ap star, are present in Kepler observations of at least three other Ap stars. Since γ Dor pulsations are seen in Ap stars, it is likely that the low frequency in KIC 8677585 is also a γ Dor pulsation. The simultaneous...... presence of both γ Dor and roAp pulsations and the unexpected detection of δ Sct and γ Dor pulsations in Ap stars present new opportunities and challenges for the interpretation of these stars. Since it is easy to confuse Am and Ap stars at classification dispersions, the nature of these Ap stars...

  18. APS SCIENCE 2016

    Energy Technology Data Exchange (ETDEWEB)

    Fenner, Richard B. [Argonne National Lab. (ANL), Argonne, IL (United States). Advanced Photon Source (APS)

    2017-05-01

    The Advanced Photon Source (APS) occupies an 80-acre site on the Argonne national laboratory campus, about 25 miles from downtown chicago, illinois. it shares the site with the center for nanoscale materials and the Advanced Protein characterization facility. for directions to Argonne, see http://www.anl.gov/directions-and-visitor-information. The APS, a national synchrotron radiation research facility operated by Argonne for the u.S. department of energy (doe) office of Science, provides this nation’s brightest high-energy x-ray beams for science. research by APS users extends from the center of the earth to outer space, from new information on combustion engines and microcircuits to new drugs and nanotechnologies whose scale is measured in billionths of a meter. The APS helps researchers illuminate answers to the challenges of our high-tech world, from developing new forms of energy, to sustaining our nation’s technological and economic competitiveness, to pushing back against the ravages of disease. research at the APS promises to have far-reaching

  19. AP Music Theory Applied

    Science.gov (United States)

    Spieker, Matthew H.

    2016-01-01

    Some American high schools include Advanced Placement (AP) Music Theory within their course offerings. Students who pass the AP exam can receive college credit either as a music or humanities credit. An AP class, however, offers music students more than future college credit; it ultimately improves musicianship skills and promotes deeper…

  20. Análise da correlação entre pico de torque, desempenho funcional e frouxidão ligamentar em indivíduos normais e com reconstrução do ligamento cruzado anterior Functional performance and knee laxity in normal individuals and in individuals submitted to anterior cruciate ligament reconstruction

    Directory of Open Access Journals (Sweden)

    Rodrigo Antunes de Vasconcelos

    2009-04-01

    Full Text Available OBJETIVO: Analisar a correlação entre os déficits musculares dos extensores e flexores do joelho através do pico de torque isocinético com os testes de salto monopodal, frouxidão ligamentar pós-operatória e questionário de função em indivíduos normais e indivíduos submetidos à reconstrução do LCA com enxerto autólogo do tendão patelar e dos tendões flexores. MÉTODOS: Foram recrutados 60 indivíduos, formando três grupos: 20 indivíduos sem lesões no joelho (grupo GC e dois grupos de 20 indivíduos submetidos à reconstrução do LCA com tendão patelar (grupo GTP ou tendões flexores (grupo GTF. RESULTADOS: Os resultados demonstraram correlação significativa entre déficits no pico de torque e testes funcionais no torque extensor nos grupos GTF e GC. Não foram observadas correlações significativas entre frouxidão ligamentar pós-operatória e questionário de Lysholm com os testes de salto e déficits no pico de torque. Em relação à diferença entre os grupos, foi observado que o grupo GTP demonstrou maior déficit do torque extensor, menor pontuação no questionário de Lysholm e maior percentagem dos indivíduos com índice de simetria entre membros (ISM OBJECTIVES: The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. METHODS: Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group and hamstrings autograft (GTF group. RESULTS: The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity

  1. Hepatoscintiangiography of normal liver and its alteration in hepatomas and liver abscess

    International Nuclear Information System (INIS)

    Bahk, Y.W.; Chung, S.K.

    1984-01-01

    This study was performed to establish normal hepatoscintiangiographic (HSA) pattern of hepatic blood flow and to investigate differential HSA findings of primary and metastatic carcinomas and abscess of the liver. HSA was carried out after intravenous bolus injection of l0 mCi of Tc-99m-phytate by obtaining sequential anterior images of 1-second exposure for 16 seconds. Observations included (1) baseline study of normal hepatic blood flow patterns by correlating with contrast angiogram, (2) time-sequence phasing of normal HSA, and (3) analysis of altered patterns in primary and metastatic carcinomas and abscess of the liver. Results were: (1) Normal HSA demonstrated 3 distinct phases of arterialization (AP), arterial hepatrogram (AHP), and portal venous hepatogram (PVHP). The means of each phase were 5.3, 6.3, and 8.3 seconds, respectively. Portal vein could be seen in all but one of 20 normal subjects. (2) Pattern changes in disease groups were early start of AP in carcinomas and very early start of AP in abscess. AP became prolonged in all disease groups. (3) Distinction between AHP and PVHP was sharp in metastasis and abscess but was unsharp in primary hepatoma. Cold area or areas became vascularized in primary hepatoma but not in abscess. Cold areas of metastasis were inhomogenously vascularized in late AP and throughout AHP and became relatively avascular as PVHP began. The cold area of abscess showed rim enhancement during AH and APH. These differences in HSA pattern were very useful in differential diagnosis of the diseases studied

  2. Autoimmune polyglandular syndrome type 3 (APS-3) among patients with premature ovarian insufficiency (POI).

    Science.gov (United States)

    Szlendak-Sauer, Katarzyna; Jakubik, Daniel; Kunicki, Michał; Skórska, Jolanta; Smolarczyk, Roman

    2016-08-01

    Autoimmune polyglandular syndrome type 3 - (APS-3), is defined as the coexistence of autoimmune thyroiditis with other non-ovarian autoimmune diseases without primary adrenal insufficiency. Additionally the definition of APS-3 also includes primary ovarian insufficiency (POI) coexistence with autoimmune thyroiditis. The main goal of that study is to assess the prevalence of APS-3 defined as coexistence of autoimmune thyroiditis with POI in population of 46 XX karyotype women with primary ovarian insufficiency (POI). The second goal is to investigate hormonal profile and insulin sensitivity in women with POI and subgroups of women with APS-3 - POI/APS-3(+) and without APS 3 - POI/APS-3(-). Anthropometric measurements, coexistence of autoimmune diseases, androgens, fasting glucose and insulin, glucose and insulin at 60' and 120' of oral glucose tolerance test (OGTT) and homeostasis model for insulin resistance (HOMA-IR), were determine in 98 patients aged between 18 and 39 with spontaneous 46 XX primary ovarian insufficiency (POI), in 33 POI/APS-3(+), 65 POI/APS-3(-), and 75 healthy controls. Continuous data were summarized by the mean±standard deviation (SD), and categorical data by number (percentages). Data were checked for normality using Shapiro-Wilk test, the comparison between groups were performed using non-parametric Mann-Whitney or Kruskall-Wallis test. Pearson's correlation coefficient was used to assess the relationships between parameters. Statistical significance was defined as p values APS-3(+) and POI/APS-3(-) showed significantly lower serum androgens in comparison to controls. Additionally women with POI/APS-3(+) showed hyperinsulinemia after 1h of OGTT; No significant differences in serum fasting glucose, insulin and during 2h OGTT between groups were observed. The prevalence of APS-3 is 33.7% in patients with spontaneous 46 XX primary ovarian insufficiency. Women with POI, POI/APS-3(+) and POI/APS-3(-) feature lower testosterone, androstendione

  3. AP1000 Design for Security

    International Nuclear Information System (INIS)

    Long, L.B.; Cummins, W.E.; Winters, J.W.

    2006-01-01

    Nuclear power plants are protected from potential security threats through a combination of robust structures around the primary system and other vital equipment, security systems and equipment, and defensive strategy. The overall objective for nuclear power plant security is to protect public health and safety by ensuring that attacks or sabotage do not challenge the ability to safely shutdown the plant or protect from radiological releases. In addition, plants have systems, features and operational strategies to cope with external conditions, such as loss of offsite power, which could be created as part of an attack. Westinghouse considered potential security threats during design of the AP1000 PWR. The differences in plant configuration, safety system design, and safe shutdown equipment between existing plants and AP1000 affect potential vulnerabilities. This paper provides an evaluation of AP1000 with respect to vulnerabilities to security threats. The AP1000 design differs from the design of operating PWRs in the US in the configuration and the functional requirements for safety systems. These differences are intentional departures from conventional PWR designs which simplify plant design and enhance overall safety. The differences between the AP1000 PWR and conventional PWRs can impact vulnerabilities to security threats. The NRC addressed security concerns as part of their reviews for AP1000 Design Certification, and did not identify any security issues of concern. However, much of the detailed security design information for the AP1000 was deferred to the combined Construction and Operating License (COL) phase as many of the security issues are site-specific. Therefore, NRC review of security issues related to the AP1000 is not necessarily complete. Further, since the AP1000 plant design differs from existing PWRs, it is not obvious that the analyses and assessments prepared for existing plants also apply to the AP1000. We conclude that, overall, the AP1000

  4. Theoretical studies on the electronic and optoelectronic properties of [A.2AP(w)/A*.2AP(WC)/C.2AP(w)/C*.2AP(WC)/C.A(w)/C*.A(WC)]-Au8 mismatch nucleobase complexes

    Science.gov (United States)

    Srivastava, Ruby

    2018-01-01

    The electronic and optoelectronic properties of [A.2AP(w)/A*.2AP(WC)/C.2AP(w)/C*.2AP(WC)/C.A(w)/ C*.A(WC)]-Au8 metal-mismatch nucleobase complexes are investigated by means of density functional theory and time-dependent methods. We selected these mispairs as 2-aminopurine (2AP) produces incorporation errors when binding with cytosine (C) into the wobble (w) C.2AP(w) mispair, and is tautomerised into Watson-Crick (WC)-like base mispair C*.2AP(WC) and less effectively produces A.2AP(w)/A*.2AP(WC) mispairs. The vertical ionisation potential, vertical electron affinity, hardness and electrophilicity index of these complexes have also been discussed. The modifications of energy levels and charge density distributions of the frontier orbitals are also analysed. The absorption spectra of these complexes lie in the visible region, which suggests their application in fluorescent-bio imaging. The mechanism of cooperativity effect is studied by molecular orbital potential (MEP), atoms-in-molecules (AIM) and natural bond orbital analyses. Most metalated pairs have smaller HOMO-LUMO band gaps than the isolated mismatch nucleobases which suggest interesting consequences for electron transfer through DNA duplexes.

  5. Tank 241-AP-107, grab samples 7AP-97-1, 7AP-97-2 and 7AP-97-3 analytical results for the final report

    International Nuclear Information System (INIS)

    Steen, F.H.

    1997-01-01

    This document is the final report for tank 241-AP-107 grab samples. Three grab samples were collected from riser 1 on September 11, 1997. Analyses were performed on samples 7AP-97-1, 7AP-97-2 and 7AP-97-3 in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) (Sasaki, 1997) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) (Rev. 1: Fowler, 1995; Rev. 2: Mulkey and Nuier, 1997). The analytical results are presented in the data summary report (Table 1). A notification was made to East Tank Farms Operations concerning low hydroxide in the tank and a hydroxide (caustic) demand analysis was requested. The request for sample analysis (RSA) (Attachment 2) received for AP-107 indicated that the samples were polychlorinated biphenyl (PCB) suspects. Therefore, prior to performing the requested analyses, aliquots were made to perform PCB analysis in accordance with the 222-S Laboratory administrative procedure, LAP-101-100. The results of this analysis indicated that no PCBs were present at 50 ppm and analysis proceeded as non-PCB samples. The results and raw data for the PCB analysis will be included in a revision to this document. The sample breakdown diagrams (Attachment 1) are provided as a cross-reference for relating the tank farm customer identification numbers with the 222-S Laboratory sample numbers and the portion of sample analyzed

  6. ELECTROCHEMICAL CORROSION TESTING OF TANKS 241-AN-102 & 241-AP-107 & 241-AP-108 IN SUPPORT OF ULTRASONIC TESTING

    Energy Technology Data Exchange (ETDEWEB)

    WYRWAS RB; DUNCAN JB

    2008-11-20

    This report presents the results of the corrosion rates that were measured using electrochemical methods for tanks 241-AN-102 (AN-102), 241-AP-107 (AP 107), and 241-AP-108 (AP-108) performed under test plant RPP-PLAN-38215. The steel used as materials of construction for AN and AP tank farms was A537 Class 1. Test coupons of A537 Class 1 carbon steel were used for corrosion testing in the AN-107, AP-107, and AP-108 tank waste. Supernate will be tested from AN-102, AP-107, and Ap-108. Saltcake testing was performed on AP-108 only.

  7. Radiation effects on active pixel sensors (APS); Effets de l'irradiation sur les capteurs a pixels actifs (APS)

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, M; David, J P [ONERA-CERT/, 31 - Toulouse (France)

    1999-07-01

    Active pixel sensor (APS) is a new generation of image sensors which presents several advantages relatively to charge coupled devices (CCDs) particularly for space applications (APS requires only 1 voltage to operate which reduces considerably current consumption). Irradiation was performed using {sup 60}Co gamma radiation at room temperature and at a dose rate of 150 Gy(Si)/h. 2 types of APS have been tested: photodiode-APS and photoMOS-APS. The results show that photoMOS-APS is more sensitive to radiation effects than photodiode-APS. Important parameters of image sensors like dark currents increase sharply with dose levels. Nevertheless photodiode-APS sensitivity is one hundred time lower than photoMOS-APS sensitivity.

  8. Children born to SLE and APS mothers.

    Science.gov (United States)

    Nalli, C; Iodice, A; Andreoli, L; Lojacono, A; Motta, M; Fazzi, E; Tincani, A

    2014-10-01

    Systemic lupus erythematosus (SLE) and antiphospholipid antibody syndrome (APS) are autoimmune diseases that affect women of childbearing age. Pregnancies in these patients carry several complications such as prematurity. Maternal IgG antiphospholipid antibodies (aPL) can cross the placenta but they don't generally cause any neonatal thrombotic event. Because of the incompleteness of the fetal blood-brain barrier, aPL could theoretically reach the fetal brain. Whether this can have an effect on brain development is still under investigation. Some studies performed in children of patients with SLE and/or APS showed an increased number of learning disabilities without impairment in intelligence level. The objectives of this article are to evaluate the neurodevelopment outcome in 30 children (median age 9 years) born to mothers with SLE and/or APS with IgG anti-beta2-glycoprotein I during the third trimester of pregnancy and found positive for the same antibodies at birth. A neurological physical exam was performed in all children. We submitted some questionnaires to the mothers: the Child Behavior CheckList (CBCL) and a homemade set of questions obtained by a team composed of rheumatologists and pediatric neurologists. Intellectual functioning was determined by the Wechsler scale for corrected age. In all children neurological physical exam and intelligence levels were found to be normal but mild behavior disorders and history of neurological manifestations were shown in three children. Offspring of patients with SLE and/or APS are generally healthy. We and others observed the occurrence of minor neurological disorders that might be related to maternal disease or to prematurity. The limited number of the available data on this sensitive issue supports the need for further studies. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Clinical manifestations of antiphospholipid syndrome (APS) with and without antiphospholipid antibodies (the so-called 'seronegative APS').

    Science.gov (United States)

    Rodriguez-Garcia, Jose Luis; Bertolaccini, Maria Laura; Cuadrado, Maria Jose; Sanna, Giovanni; Ateka-Barrutia, Oier; Khamashta, Munther A

    2012-02-01

    Although the medical literature currently provides a growing number of isolated case reports of patients with clinically well-defined antiphospholipid syndrome (APS) and persistently negative antiphospholipid antibodies (aPL), there are no studies including a series of patients addressing the clinical features of this condition. The authors assessed clinical manifestations of APS in 154 patients: 87 patients with seropositive APS and 67 patients with thrombosis and/or pregnancy morbidity persistently negative for aPL and presenting with at least two additional non-criteria manifestations of APS (the so-called 'seronegative APS', SN-APS). Patients were interviewed at the time of recruitment, and a retrospective file review was carried out. There were no significant differences in the frequency of thrombotic events or obstetric morbidity in patients with SN-APS versus patients with seropositive APS: deep vein thrombosis (31.4% vs 31.0%), pulmonary embolism (23.8% vs 28.7%), stroke (14.9% vs 17.2%), transient ischaemic attack (11.9% vs 10.3%), early spontaneous abortions (67.1% vs 52.1%), stillbirths (62.5% vs 59.4%), prematurity (28.1% vs 21.7%) or pre-eclampsia (28.1% vs 23.1%). Classic and SN-APS patients show similar clinical profiles. The results suggest that clinical management in patients with APS should not be based only on the presence of conventional aPL.

  10. Radiation effects on active pixel sensors (APS)

    International Nuclear Information System (INIS)

    Cohen, M.; David, J.P.

    1999-01-01

    Active pixel sensor (APS) is a new generation of image sensors which presents several advantages relatively to charge coupled devices (CCDs) particularly for space applications (APS requires only 1 voltage to operate which reduces considerably current consumption). Irradiation was performed using 60 Co gamma radiation at room temperature and at a dose rate of 150 Gy(Si)/h. 2 types of APS have been tested: photodiode-APS and photoMOS-APS. The results show that photoMOS-APS is more sensitive to radiation effects than photodiode-APS. Important parameters of image sensors like dark currents increase sharply with dose levels. Nevertheless photodiode-APS sensitivity is one hundred time lower than photoMOS-APS sensitivity

  11. Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations (II): thrombocytopenia and skin manifestations.

    Science.gov (United States)

    Cervera, R; Tektonidou, M G; Espinosa, G; Cabral, A R; González, E B; Erkan, D; Vadya, S; Adrogué, H E; Solomon, M; Zandman-Goddard, G; Shoenfeld, Y

    2011-02-01

    The objectives of the 'Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations' were to assess the clinical utility of the international consensus statement on classification criteria and treatment guidelines for the catastrophic APS, to identify and grade the studies that analyze the relationship between the antiphospholipid antibodies and the non-criteria APS manifestations, and to present the current evidence regarding the accuracy of these non-criteria APS manifestations for the detection of patients with APS. This article summarizes the studies analyzed on thrombocytopenia and skin manifestations, and presents the recommendations elaborated by the Task Force after this analysis.

  12. Radiation effects on active pixel sensors (APS); Effets de l'irradiation sur les capteurs a pixels actifs (APS)

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, M.; David, J.P. [ONERA-CERT/, 31 - Toulouse (France)

    1999-07-01

    Active pixel sensor (APS) is a new generation of image sensors which presents several advantages relatively to charge coupled devices (CCDs) particularly for space applications (APS requires only 1 voltage to operate which reduces considerably current consumption). Irradiation was performed using {sup 60}Co gamma radiation at room temperature and at a dose rate of 150 Gy(Si)/h. 2 types of APS have been tested: photodiode-APS and photoMOS-APS. The results show that photoMOS-APS is more sensitive to radiation effects than photodiode-APS. Important parameters of image sensors like dark currents increase sharply with dose levels. Nevertheless photodiode-APS sensitivity is one hundred time lower than photoMOS-APS sensitivity.

  13. Center for Geometrisk Metrologi CGM ApS, Årsberetning 2001 til DANAK

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    Denne årsberetning omfatter CGM ApS' akkrediterede virksomhed i kalenderåret 2001. Årsberetningen er udarbejdet til DANAK (Dansk Akkreditering, Erhvervsfremme Styrelsen), som led i opfyldelsen af laboratoriets informationspligt i henhold til gældende regler (Teknisk Forskrift Nr. TF4 af 2000...

  14. Thermal Decomposition Characteristics of Orthorhombic Ammonium Perchlorate (o-AP) and an 0-AP/HTPB-Based Propellant

    International Nuclear Information System (INIS)

    BEHRENS JR., RICHARD; MINIER, LEANNA M.G.

    1999-01-01

    A study to characterize the low-temperature reactive processes for o-AP and an AP/HTPB-based propellant (class 1.3) is being conducted in the laboratory using the techniques of simultaneous thermogravimetric modulated beam mass spectrometry (STMBMS) and scanning electron microscopy (SEM). The results presented in this paper are a follow up of the previous work that showed the overall decomposition to be complex and controlled by both physical and chemical processes. The decomposition is characterized by the occurrence of one major event that consumes up to(approx)35% of the AP, depending upon particle size, and leaves behind a porous agglomerate of AP. The major gaseous products released during this event include H(sub 2)O, O(sub 2), Cl(sub 2), N(sub 2)O and HCl. The recent efforts provide further insight into the decomposition processes for o-AP. The temporal behaviors of the gas formation rates (GFRs) for the products indicate that the major decomposition event consists of three chemical channels. The first and third channels are affected by the pressure in the reaction cell and occur at the surface or in the gas phase above the surface of the AP particles. The second channel is not affected by pressure and accounts for the solid-phase reactions characteristic of o-AP. The third channel involves the interactions of the decomposition products with the surface of the AP. SEM images of partially decomposed o-AP provide insight to how the morphology changes as the decomposition progresses. A conceptual model has been developed, based upon the STMBMS and SEM results, that provides a basic description of the processes. The thermal decomposition characteristics of the propellant are evaluated from the identities of the products and the temporal behaviors of their GFRs. First, the volatile components in the propellant evolve from the propellant as it is heated. Second, the hot AP (and HClO(sub 4)) at the AP-binder interface oxidize the binder through reactions that

  15. Comparative analysis between radiographic views for knee osteoarthrosis (bipedal AP versus monopedal AP

    Directory of Open Access Journals (Sweden)

    Rodrigo Pires e Albuquerque

    2013-08-01

    Full Text Available OBJECTIVE: A comparative analysis by applying the criteria of the original classification Ahlbäck in the anteroposterior (AP bipedal knee in extension and anteroposterior (AP monopodal knee in symptomatic knee arthrosis. With this analysis we intend to observe the agreement, any advantage or difference between the incidence and degree of joint involvement between the orthopedic surgeons and radiologists with the referring physician. METHODS: From January 2012 to March 2012, was a prospective study of 60 symptomatic arthrosis knees (60 patients, clinically selected group of outpatient knee and radiographic proposals submitted to the search. Of the 60 patients, 39 were female and 21 male, mean age 64 years (ranging from 50 to 84 years. Of the 60 knees studied, 37 corresponded to the right side and 23 on the left side. Statistical analysis was performed by Kappa statistics, which evaluates the interobserver agreement for qualitative data. RESULTS: According to the scale of Ahlbäck, there was a significant agreement (p < 0.0001 intra-observer in the classification of knee osteoarthritis among the five evaluators. There was a significant agreement (p < 0.0001 with inter-observer referring physician in the incidence of AP monopodal and AP bipedal for the four raters. CONCLUSION: The study found no difference between the incidence in the AP monopodal versus AP bipedal in osteoarthritis of the knee.

  16. AIRE variations in Addison's disease and autoimmune polyendocrine syndromes (APS): partial gene deletions contribute to APS I.

    Science.gov (United States)

    Bøe Wolff, A S; Oftedal, B; Johansson, S; Bruland, O; Løvås, K; Meager, A; Pedersen, C; Husebye, E S; Knappskog, P M

    2008-03-01

    Autoimmune Addison's disease (AAD) is often associated with other components in autoimmune polyendocrine syndromes (APS). Whereas APS I is caused by mutations in the AIRE gene, the susceptibility genes for AAD and APS II are unclear. In the present study, we investigated whether polymorphisms or copy number variations in the AIRE gene were associated with AAD and APS II. First, nine SNPs in the AIRE gene were analyzed in 311 patients with AAD and APS II and 521 healthy controls, identifying no associated risk. Second, in a subgroup of 25 of these patients, AIRE sequencing revealed three novel polymorphisms. Finally, the AIRE copy number was determined by duplex quantitative PCR in 14 patients with APS I, 161 patients with AAD and APS II and in 39 healthy subjects. In two Scandinavian APS I patients previously reported to be homozygous for common AIRE mutations, we identified large deletions of the AIRE gene covering at least exon 2 to exon 8. We conclude that polymorphisms in the AIRE gene are not associated with AAD and APS II. We further suggest that DNA analysis of the parents of patients found to be homozygous for mutations in AIRE, always should be performed.

  17. Autoantibody profiling in APS.

    Science.gov (United States)

    Roggenbuck, D; Somma, V; Schierack, P; Borghi, M O; Meroni, P L

    2014-10-01

    The international consensus for the classification of antiphospholipid syndrome (APS) requires clinical and laboratory criteria to be considered at an equal level for diagnosing APS. Thus, detection of antiphospholipid antibodies (aPL) being a hallmark of APS has been the object of intensive investigation over the past 40 years. However, appropriate detection of aPL still remains a laboratory challenge due to their heterogeneity comprising autoantibodies reactive to different phospholipid-binding plasma proteins, such as beta-2 glycoprotein I (β2GPI) and prothrombin. The relevance of aPL interacting with phospholipids other than cardiolipin (CL, diphosphatidylglycerol), such as phosphatidylserine (PS), remains elusive with regard to the diagnosis of APS. Recently, the concept of aPL profiling has been introduced to assess the risk of thrombotic complications in patients with APS. New assay techniques, apart from enzyme-linked immunosorbent assays (ELISAs) recommended by the international consensus for the classification of APS, have been proposed for multiplexing of aPL testing. Line immunoassays (LIAs) employing a novel hydrophobic solid phase for the simultaneous detection of different aPL seem to be an intriguing alternative. We evaluated a novel multiplex LIA employing a hydrophobic membrane coated with different phospholipid (PL)-binding proteins or PLs. The performance characteristics of this new multiplexing assay technique demonstrated its usefulness for aPL profiling. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Physico-chemical profiles of the wobble ↔ Watson-Crick G*·2AP(w) ↔ G·2AP(WC) and A·2AP(w) ↔ A*·2AP(WC) tautomerisations: a QM/QTAIM comprehensive survey.

    Science.gov (United States)

    Brovarets', Ol'ha O; Voiteshenko, Ivan S; Hovorun, Dmytro M

    2017-12-20

    This study is intended to clarify in detail the tautomeric transformations of the wobble (w) G*·2AP(w) and A·2AP(w) nucleobase mispairs involving 2-aminopurine (2AP) into the Watson-Crick (WC) G·2AP(WC) and A*·2AP(WC) base mispairs (asterisks denote mutagenic tautomers of the DNA bases), respectively, by quantum-mechanical methods and Bader's Quantum Theory of Atoms in Molecules. Our previously reported methodology has been used, which allows the evolution of the physico-chemical parameters to be tracked along the entire internal reaction coordinate (IRC), not exclusively in the stationary states of these reactions. These biologically important G*·2AP(w) ↔ G·2AP(WC) and A·2AP(w) ↔ A*·2AP(WC) w ↔ WC tautomerisations, which are involved in mutagenic tautomerically-conformational pathways, determine the origin of the transitions and transversions induced by 2AP. In addition, it is established that they proceed through planar, highly stable, zwitterionic transition states and they exhibit similar physico-chemical profiles and stages of sequential intrapair proton transfer, followed by spatial rearrangement of the nucleobases relative to each other within the base pairs. These w ↔ WC tautomerisations occur non-dissociatively and are accompanied by a significant alteration in geometry (from wobble to Watson-Crick and vice versa) and redistribution of the specific intermolecular interactions, which can be divided into 10 patterns including AHB H-bonds and loosened A-H-B covalent bridges along the IRC of tautomerisation. Based on the redistribution of the geometrical and electron-topological parameters of the intrapair hydrogen bonds, exactly 9 key points have been allocated to characterize the evolution of these reactions.

  19. Differences Between Men and Women in Balance and Tremor in Relation to Plantar Fascia Laxity During the Menstrual Cycle.

    Science.gov (United States)

    Lee, Haneul; Petrofsky, Jerrold

    2018-03-01

      Although much attention has been paid to the effect of estrogen on the knee ligaments, little has been done to examine the ligaments in the foot, such as the plantar fascia, and how they may be altered during the menstrual cycle.   To (1) examine sex differences in plantar fascia thickness and laxity and postural sway and (2) identify any menstrual cycle effects on plantar fascia laxity, postural sway, and neuromuscular tremor between menstruation and the ovulation phase.   Case-control study.   Research laboratory.   Fifteen healthy women (age = 25.9 ± 1.8 years) and 15 healthy men (age = 27.3 ± 2.0 years) volunteered to participate in this study.   We asked participants to perform 8 balance tasks on a force platform while we assessed postural sway and tremor.   Plantar fascia length and thickness unloaded and loaded with body weight were measured via ultrasound. Postural sway and tremor were measured using a force platform.   Plantar fascia length and thickness with pressure were greater in ovulating women compared with men ( P women during menstruation and men. Postural sway and tremor were greater at ovulation than during menstruation ( P men had less sway than ovulating women on the 3 most difficult balance tasks ( P women. Postural sway and tremor in men were the same as in women during menstruation. These findings support the need to be aware of the effect of sex hormones on balance to prevent lower extremity injuries during sport activities.

  20. Lead Discovery for Alzheimer’s Disease Related Target Protein RbAp48 from Traditional Chinese Medicine

    Directory of Open Access Journals (Sweden)

    Hung-Jin Huang

    2014-01-01

    Full Text Available Deficiency or loss of function of Retinoblastoma-associated proteins (RbAp48 is related with Alzheimer’s disease (AD, and AD disease is associated with age-related memory loss. During normal function, RbAp48 forms a complex with the peptide FOG-1 (friend of GATA-1 and has a role in gene transcription, but an unstable complex may affect the function of RbAp48. This study utilizes the world’s largest traditional Chinese medicine (TCM database and virtual screening to provide potential compounds for RbAp48 binding. A molecular dynamics (MD simulation was employed to understand the variations after protein-ligand interaction. FOG1 was found to exhibit low stability after RbAp48 binding; the peptide displayed significant movement from the initial docking position, a phenomenon which matched the docking results. The protein structure of the other TCM candidates was not variable during MD simulation and had a greater stable affinity for RbAp48 binding than FOG1. Our results reveal that the protein structure does not affect ligand binding, and the top three TCM candidates Bittersweet alkaloid II, Eicosandioic acid, and Perivine might resolve the instability of the RbAp48-FOG1 complex and thus be used in AD therapy.

  1. AP1000{sup R} nuclear power plant safety overview for spent fuel cooling

    Energy Technology Data Exchange (ETDEWEB)

    Gorgemans, J.; Mulhollem, L.; Glavin, J.; Pfister, A.; Conway, L.; Schulz, T.; Oriani, L.; Cummins, E.; Winters, J. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    The AP1000{sup R} plant is an 1100-MWe class pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and costs. The AP1000 design uses passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems such as AC power, component cooling water, service water or HVAC. Furthermore, these passive features 'fail safe' during a non-LOCA event such that DC power and instrumentation are not required. The AP1000 also has simple, active, defense-in-depth systems to support normal plant operations. These active systems provide the first level of defense against more probable events and they provide investment protection, reduce the demands on the passive features and support the probabilistic risk assessment. The AP1000 passive safety approach allows the plant to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action, meeting the expectations provided in the U.S. Utility Requirement Document and the European Utility Requirements for passive plants. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. In line with the AP1000 approach to safety described above, the AP1000 plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for design-basis events and beyond design-basis accidents. During normal and abnormal conditions, defense-in-depth and other systems provide highly reliable spent fuel pool cooling. They rely on off-site AC power or the on-site standby diesel generators. For unlikely design basis events with an extended loss of AC power (i.e., station blackout) or loss of heat sink or both, spent fuel cooling can still be provided indefinitely: - Passive systems, requiring minimal or no operator actions, are sufficient for at least 72 hours under all

  2. AP4M1 is abnormally expressed in oxygen-glucose deprived hippocampal neurons.

    Science.gov (United States)

    Zhang, J; Cheng, X Y; Sheng, G Y

    2014-03-20

    AP4M1 mutations have been suggested to be associated with autosomal recessive cerebral palsy syndrome. But the pathogenic mechanism remains uncertain. The purpose of this study is to investigate whether and how AP4M1 expression is changed in injured neurons. Primary cultured hippocampal neurons were prepared for this experiment. They were subjected to oxygen-glucose deprivation (OGD) leading to apoptosis, mimicking brain ischemia. Neuron-specific enolase (NSE) was labeled immunofluorescently to confirm that the purity of neuron was higher than 90%. Real-time PCR and western blotting were performed to measure the gene expression. AP4M1 was labeled with MAP2 or Tau-1 to observe the distribution. We found that the AP4M1 protein levels immediately after the procedure were similar between the OGD group and the sham group. However, down-regulation was observed 12h after the reperfusion, and became more notable at 24h. The real-time PCR showed similar results, except that the down-regulation of mRNA was able to be detected immediately after the OGD. Immunofluorescent labeling revealed AP4M1 distributed in the dendrites of normal neurons, but it redistributed to the axons after the OGD procedure. In conclusion, AP4M1 is not only down-regulated at both the mRNA and protein levels, but also redistributed from dendrites to axons in oxygen-glucose deprived hippocampal neurons. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Expression of activator protein-1 (AP-1) family members in breast cancer

    International Nuclear Information System (INIS)

    Kharman-Biz, Amirhossein; Gao, Hui; Ghiasvand, Reza; Zhao, Chunyan; Zendehdel, Kazem; Dahlman-Wright, Karin

    2013-01-01

    The activator protein-1 (AP-1) transcription factor is believed to be important in tumorigenesis and altered AP-1 activity was associated with cell transformation. We aimed to assess the potential role of AP-1 family members as novel biomarkers in breast cancer. We studied the expression of AP-1 members at the mRNA level in 72 primary breast tumors and 37 adjacent non-tumor tissues and evaluated its correlation with clinicopathological parameters including estrogen receptor (ER), progesterone receptor (PR) and HER2/neu status. Expression levels of Ubiquitin C (UBC) were used for normalization. Protein expression of AP-1 members was assessed using Western blot analysis in a subset of tumors. We used student’s t-test, one-way ANOVA, logistic regression and Pearson’s correlation coefficient for statistical analyses. We found significant differences in the expression of AP-1 family members between tumor and adjacent non-tumor tissues for all AP-1 family members except Fos B. Fra-1, Fra-2, Jun-B and Jun-D mRNA levels were significantly higher in tumors compared to adjacent non-tumor tissues (p < 0.001), whilst c-Fos and c-Jun mRNA levels were significantly lower in tumors compared with adjacent non-tumor tissues (p < 0.001). In addition, Jun-B overexpression had outstanding discrimination ability to differentiate tumor tissues from adjacent non-tumor tissues as determined by ROC curve analysis. Moreover, Fra-1 was significantly overexpressed in the tumors biochemically classified as ERα negative (p = 0.012) and PR negative (p = 0.037). Interestingly, Fra-1 expression was significantly higher in triple-negative tumors compared with luminal carcinomas (p = 0.01). Expression levels of Fra-1 and Jun-B might be possible biomarkers for prognosis of breast cancer

  4. Metallized solid rocket propellants based on AN/AP and PSAN/AP for access to space

    Science.gov (United States)

    Levi, S.; Signoriello, D.; Gabardi, A.; Molinari, M.; Galfetti, L.; Deluca, L. T.; Cianfanelli, S.; Klyakin, G. F.

    2009-09-01

    Solid rocket propellants based on dual mixes of inorganic crystalline oxidizers (ammonium nitrate (AN) and ammonium perchlorate (AP)) with binder and a mixture of micrometric-nanometric aluminum were investigated. Ammonium nitrate is a low-cost oxidizer, producing environment friendly combustion products but with lower specific impulse compared to AP. The better performance obtained with AP and the low quantity of toxic emissions obtained by using AN have suggested an interesting compromise based on a dual mixture of the two oxidizers. To improve the thermal response of raw AN, different types of phase stabilized AN (PSAN) and AN/AP co-crystals were investigated.

  5. Addendum: ``Hard X-Rays and Gamma Rays from Type Ia Supernovae'' (ApJ, 492, 228 [1998])

    Science.gov (United States)

    Höflich, Peter; Wheeler, J. C.

    2004-04-01

    We report a subtle error in the normalization of the absolute flux published in our original article (hereafter HWK98), and some minor updates. The normalization problem is related to the post-processing. As a consequence, the reported line fluxes are too large at early times. Note that Figure 1 of P. Höflich (ApJ, 492, 228 [1998]) has been transferred from HWK98. Results of previous papers are not affected (E. Müller, P. Höflich, A. M. Khokhlov, & E. Müller, ApJ, 492, 228 [1998]; P. Höflich, A. M. Khokhlov, & E. Müller, ApJ, 492, 228 [1998]). For calculating the γ-ray spectra, the γ-ray transport is solved via a Monte Carlo code that produces an output file containing the Eddington flux, the energy input by radioactive decay and escape probability, ζ, of γ-ray photons. In a postprocessing step, the spectrum is renormalized and convolved with the instrumental response function of the γ-ray telescope. A two-step procedure is used to obtain the emergent spectra to separate the CPU-intensive Monte Carlo transport calculation from the ``fast'' second step, allowing us to study the influence of the instrument on the observables (e.g., E. Müller, P. Höflich, A. M. Khokhlov, & E. Müller, ApJ, 492, 228 [1998

  6. AP1000. The PWR revisited

    International Nuclear Information System (INIS)

    Gaio, P.

    2006-01-01

    The distinguishing features of Westinghouse's AP1000 advanced passive pressurized water reactor are highlighted. In particular, the AP1000's passive safety features are described as well as their implications for simplifying the design, construction, and operation of this design compared to currently operating plants, and significantly increasing safety margins over current plants as well. The AP1000 design specifically incorporates the knowledge acquired from the substantial accumulation of power reactor operating experience and benefits from the application of the Probabilistic Risk Assessment in the design process itself. The AP1000 design has been certified by the US Nuclear Regulatory Commission under its new rules for licensing new nuclear plants, 10 CFR Part 52, and is the subject of six combined Construction and Operating License applications now being developed. Currently the AP1000 design is being assessed against the EUR Rev C requirements for new nuclear power plants in Europe. (author)

  7. AP statistics crash course

    CERN Document Server

    D'Alessio, Michael

    2012-01-01

    AP Statistics Crash Course - Gets You a Higher Advanced Placement Score in Less Time Crash Course is perfect for the time-crunched student, the last-minute studier, or anyone who wants a refresher on the subject. AP Statistics Crash Course gives you: Targeted, Focused Review - Study Only What You Need to Know Crash Course is based on an in-depth analysis of the AP Statistics course description outline and actual Advanced Placement test questions. It covers only the information tested on the exam, so you can make the most of your valuable study time. Our easy-to-read format covers: exploring da

  8. A novel homozygous AP4B1 mutation in two brothers with AP-4 deficiency syndrome and ocular anomalies.

    Science.gov (United States)

    Accogli, Andrea; Hamdan, Fadi F; Poulin, Chantal; Nassif, Christina; Rouleau, Guy A; Michaud, Jacques L; Srour, Myriam

    2018-04-01

    Adaptor protein complex-4 (AP-4) is a heterotetrameric protein complex which plays a key role in vesicle trafficking in neurons. Mutations in genes affecting different subunits of AP-4, including AP4B1, AP4E1, AP4S1, and AP4M1, have been recently associated with an autosomal recessive phenotype, consisting of spastic tetraplegia, and intellectual disability (ID). The overlapping clinical picture among individuals carrying mutations in any of these genes has prompted the terms "AP-4 deficiency syndrome" for this clinically recognizable phenotype. Using whole-exome sequencing, we identified a novel homozygous mutation (c.991C>T, p.Q331*, NM_006594.4) in AP4B1 in two siblings from a consanguineous Pakistani couple, who presented with severe ID, progressive spastic tetraplegia, epilepsy, and microcephaly. Sanger sequencing confirmed the mutation was homozygous in the siblings and heterozygous in the parents. Similar to previously reported individuals with AP4B1 mutations, brain MRI revealed ventriculomegaly and white matter loss. Interestingly, in addition to the typical facial gestalt reported in other AP-4 deficiency cases, the older brother presented with congenital left Horner syndrome, bilateral optic nerve atrophy and cataract, which have not been previously reported in this condition. In summary, we report a novel AP4B1 homozygous mutation in two siblings and review the phenotype of AP-4 deficiency, speculating on a possible role of AP-4 complex in eye development. © 2018 Wiley Periodicals, Inc.

  9. Isokinetic torque peak and hamstrings/quadriceps ratios in endurance athletes with anterior cruciate ligament laxity Pico de torque isocinético e relação ísquios-tibiais/quadríceps em atletas de endurance com frouxidão do ligamento cruzado anterior

    Directory of Open Access Journals (Sweden)

    Eliane Magaieski Portes

    2007-01-01

    Full Text Available PURPOSE: To evaluate torque and the hamstring/quadriceps ratio of the knee of athletes with and without anterior cruciate ligament laxity. METHODS: Twenty-eight male athletes, 19 without anterior cruciate ligament laxity and 9 with anterior cruciate ligament laxity, were evaluated with an isokinetic machine model Cybex 770. The peak torque of quadriceps and hamstrings was compared, and the hamstring/quadriceps ratio on the constant angular speed of 60º per second were also compared. RESULTS: In athletes with anterior cruciate ligament laxity, the peak torque values (right and left knees of flexors (120 ± 15 and 116 ± 15 Nm and of extensors (218 ± 36 Nm and 207 ± 26 Nm were not different than those of athletes without laxity (109 ± 21 Nm and 111 ± 22 Nm; 191 ± 5 Nm and 188 ± 35 Nm. The hamstring/quadriceps ratio of athletes with laxity (right: 57 ± 6% and left: 56 ± 8% did not differ from those without anterior cruciate ligament laxity (right: 58 ± 9% and left: 58 ± 7%. CONCLUSIONS: The anterior cruciate ligament laxity of long distances running athletes did not significantly alter the peak torque of flexors and of extensors or the hamstring/quadriceps ratio.OBJETIVO: Avaliar o torque e a relação de forças entre ísquios-tibiais/quadríceps dos joelhos de atletas corredores de longas distâncias com e sem frouxidão do ligamento cruzado anterior. METODOLOGIA: Vinte e oito atletas do gênero masculino, 19 sem frouxidão do ligamento cruzado anterior e 9 com frouxidão do ligamento cruzado anterior foram avaliados com aparelho isocinético modelo Cybex 770. Comparou-se o pico de torque dos quadríceps e dos ísquios-tibiais e a relação ísquios-tibiais/quadríceps na velocidade angular constante de 60º por segundo. Os dados obtidos foram comparados por meio dos testes t de Student e para dados pareados (membros direito e esquerdo e o nível de significância estabelecido foi p < 0,05. RESULTADOS: Nos atletas com frouxidão do

  10. Project W-211, initial tank retrieval systems, description of operations for 241-AP-102 and 241-AP-104

    Energy Technology Data Exchange (ETDEWEB)

    RIECK, C.A.

    1999-02-25

    The primary purpose of the Initial Tank Retrieval Systems (ITRS) is to provide systems for retrieval of radioactive wastes stored in underground double-shell tanks (DSTS) for transfer to alternate storage, evaporation, pretreatment or treatment, while concurrently reducing risks associated with safety watch list and other DSTs. This Description of Operations (DOO) defines the control philosophy for the waste retrieval system for tanks 241-AP-102 (AP-102) and 241-AP-104 (AP-104). This DOO will provide a basis for the detailed design of the Retrieval Control System (RCS) for AP-102 and AP-104 and establishes test criteria for the RCS. The test criteria will be used during qualification testing and acceptance testing to verify operability.

  11. Project W-211, initial tank retrieval systems, description of operations for 241-AP-102 and 241-AP-104

    International Nuclear Information System (INIS)

    RIECK, C.A.

    1999-01-01

    The primary purpose of the Initial Tank Retrieval Systems (ITRS) is to provide systems for retrieval of radioactive wastes stored in underground double-shell tanks (DSTS) for transfer to alternate storage, evaporation, pretreatment or treatment, while concurrently reducing risks associated with safety watch list and other DSTs. This Description of Operations (DOO) defines the control philosophy for the waste retrieval system for tanks 241-AP-102 (AP-102) and 241-AP-104 (AP-104). This DOO will provide a basis for the detailed design of the Retrieval Control System (RCS) for AP-102 and AP-104 and establishes test criteria for the RCS. The test criteria will be used during qualification testing and acceptance testing to verify operability

  12. Arsenic may be involved in fluoride-induced bone toxicity through PTH/PKA/AP1 signaling pathway.

    Science.gov (United States)

    Zeng, Qi-bing; Xu, Yu-yan; Yu, Xian; Yang, Jun; Hong, Feng; Zhang, Ai-hua

    2014-01-01

    Chronic exposure to combined fluoride and arsenic continues to be a major public health problem worldwide, affecting thousands of people. In recent years, more and more researchers began to focus on the interaction between the fluorine and the arsenic. In this study, the selected investigation site was located in China. The study group was selected from people living in fluoride-arsenic polluted areas due to burning coal. The total number of participants was 196; including the fluoride-arsenic anomaly group (130) and the fluoride-arsenic normal group (63). By observing the changes in gene and protein expression of PTH/PKA/AP1 signaling pathway, the results show that fluoride can increase the expression levels of PTH, PKA, and AP1, but arsenic can only affect the expression of AP1; fluoride and arsenic have an interaction on the expression of AP1. Further study found that fluoride and arsenic can affect the mRNA expression level of c-fos gene (AP1 family members), and have an interaction on the expression of c-fos, but not c-jun. The results indicate that PTH/PKA/AP1 signaling pathway may play an important role in bone toxicity of fluoride. Arsenic can affect the expression of c-fos, thereby affecting the expression of transcription factor AP1, indirectly involved in fluoride-induced bone toxicity. Copyright © 2013. Published by Elsevier B.V.

  13. Greenhouse evaluation of Bacillus subtilis AP-01 and Trichoderma harzianum AP-001 in controlling tobacco diseases.

    Science.gov (United States)

    Maketon, Monchan; Apisitsantikul, Jirasak; Siriraweekul, Chatchai

    2008-04-01

    Two biological control agents, Bacillus subtilis AP-01 (Larminar(™)) and Trichoderma harzianum AP-001 (Trisan(™)) alone or/in combination were investigated in controlling three tobacco diseases, including bacterial wilt (Ralstonia solanacearum), damping-off (Pythium aphanidermatum), and frogeye leaf spot (Cercospora nicotiana). Tests were performed in greenhouse by soil sterilization prior to inoculation of the pathogens. Bacterial-wilt and damping off pathogens were drenched first and followed with the biological control agents and for comparison purposes, two chemical fungicides. But for frogeye leaf spot, which is an airborne fungus, a spraying procedure for every treatment including a chemical fungicide was applied instead of drenching. Results showed that neither B. subtilis AP-01 nor T harzianum AP-001 alone could control the bacterial wilt, but when combined, their controlling capabilities were as effective as a chemical treatment. These results were also similar for damping-off disease when used in combination. In addition, the combined B. subtilis AP-01 and T. harzianum AP-001 resulted in a good frogeye leaf spot control, which was not significantly different from the chemical treatment.

  14. Quantitative kinetics of In-111 autologous (In-AP) and homologous (Cr-HP) platelets in immune thrombocytopenic purpura (ITP)

    International Nuclear Information System (INIS)

    Lotter, M.G.; Heyns, A.D.P.; Badenhorst, P.N.; Minnaar, P.C.

    1984-01-01

    Contrary to the accepted view, the authors have found that platelet turnover is not always increased in ITP if the mean platelet survival time (PS) is measured with In-AP. The authors investigated the possible cause of the discrepancy by comparing kinetics of In-AP with those of Cr-HP in 10 patients with ITP. PS was estimated with the multiple hit model. The equilibrium and final in vivo distribution of In-AP was quantitated with the geometrical mean method. The patients could be divided into either those with splenic or diffuse RES platelet destruction. The authors conclude that in ITP platelet survival of In-AP is significantly (P < .05) longer than that of Cr-HP. Platelet turnover measured with In-AP is only normal in patients with mainly splenic platelet sequestration. Results with Cr-HP give a false impression of PS. It seems that in ITP those patients with severe disease also have a platelet production defect

  15. ApS de Mediación Artística: Mujer y violencia de género

    OpenAIRE

    GUILLEM CASAÑ, LIVIA

    2018-01-01

    Proyecto basado en ApS a través de la programación de acción de Mediación Artística dirigida a un colectivo con necesidades especiales, en este caso, mujeres que han sufrido maltrato. Proponiendo realizar una serie de prácticas artísticas que tienen como objetivos ayudar a potenciar la confianza, el desarrollo integral, la autonomía, la cooperación y la superación de conflictos. Todo ello coordinado junto con las terapeutas de la Asociación ALANNA y LILITH. Project based on ApS through the...

  16. Assessment of efficacy and safety of a fractionated bipolar radiofrequency device for the treatment of lower face wrinkles and laxity.

    Science.gov (United States)

    Jiang, Yueqi; Zhang, Xuting; Lu, Zhong; Gold, Michael H

    2018-04-18

    Skin aging, as a natural course, is a gradual process. It can be classified as either intrinsic or photo-aging. In recent years, as the attention to lower face wrinkles and laxity has raised significantly, the demands to facial rejuvenation also increased, along with a variety of technologies coming into being. Fractional bipolar RF as a novel means of rejuvenation has been used in clinical practice, but questions remain in terms of its efficacy and safety. Considering a large population in our country and huge demands for skin tightening, we did this research to evaluate the efficacy and safety of fractional bipolar radiofrequency.

  17. An AP Calculus Classroom Amusement Park

    Science.gov (United States)

    Ferguson, Sarah

    2016-01-01

    Throughout the school year, AP Calculus teachers strive to teach course content comprehensively and swiftly in an effort to finish all required material before the AP Calculus exam. As early May approaches and the AP Calculus test looms, students and teachers nervously complete lessons, assignments, and assessments to ensure student preparation.…

  18. The normal transverse mesocolon and involvement of the mesocolon in acute pancreatitis: an MRI study.

    Science.gov (United States)

    Chi, Xiao Xiao; Zhang, Xiao Ming; Chen, Tian Wu; Huang, Xiao Hua; Yang, Lin; Tang, Wei; Xiao, Bo

    2014-01-01

    To study the MRI findings of the normal transverse mesocolon and the involvement of the mesocolon in acute pancreatitis (AP) as well as the relationship between the involvement of the mesocolon and the severity of AP. Forty patients without pancreatic disorders were retrospectively analyzed to observe the normal transverse mesocolon using MRI; 210 patients with AP confirmed by clinical and laboratory tests were retrospectively analyzed using MRI to observe transverse-mesocolon involvement (TMI). The severity of TMI was recorded as zero points (no abnormalities and transverse-mesocolon vessel involvement), one point (linear and patchy signal in the transverse mesocolon) or two points (transverse-mesocolon effusion). The AP severity was graded by the MRI severity index (MRSI) and the Acute Physiology And Chronic Healthy Evaluation II (APACHE II) scoring system. The correlations of TMI with MRSI and APACHE-II were analyzed. In a normal transverse mesocolon, the display rates of the middle colic artery, the middle colic vein and the gastrocolic trunk on MRI were 95.0%, 82.5% and 100.0%, respectively. Of the 210 patients with AP, 130 patients (61.9%) had TMI. According to the TMI grading, 40%, 39% and 20% of the patients were graded at zero, one and two points, respectively. TMI was strongly correlated with the MRSI score (r = 0.759, P = 0.000) and the APACHE-II score (r = 0.384, P = 0.000). MRI could be used to visualize transverse-mesocolon involvement. The severity of TMI could reflect that of AP in the clinical setting and imaging. TMI might be a supplementary indicator of the severity of AP.

  19. AP1000, a nuclear central of advanced design; AP1000, una central nuclear de diseno avanzado

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, N.; Viais J, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: nhm@nuclear.inin.mx

    2005-07-01

    The AP1000 is a design of a nuclear reactor of pressurized water (PWR) of 1000 M We with characteristic of safety in a passive way; besides presenting simplifications in the systems of the plant, the construction, the maintenance and the safety, the AP1000 is a design that uses technology endorsed by those but of 30 years of operational experience of the PWR reactors. The program AP1000 of Westinghouse is focused to the implementation of the plant to provide improvements in the economy of the same one and it is a design that is derived directly of the AP600 designs. On September 13, 2004 the US-NRC (for their initials in United States- Nuclear Regulatory Commission) approved the final design of the AP1000, now Westinghouse and the US-NRC are working on the whole in a complete program for the certification. (Author)

  20. Applicability of RELAP5 for safety analysis of AP600 and PIUS reactors

    International Nuclear Information System (INIS)

    Motloch, C.G.; Modro, S.M.

    1990-01-01

    An assessment of the applicability of using RELAP5 for performing safety analyses of the AP600 and PIUS advanced reactor concepts is being performed. This ongoing work is part of a larger safety assessment of advanced reactors sponsored by the United States Nuclear Regulatory Commission. RELAP5 models and correlations are being reviewed from the perspective of the new AP600 and PIUS phenomena and features that could be important to reactor safety. The purpose is to identify those areas in which new mathematical models of physical phenomena would be required to be added to RELAP5. In most cases, the AP600 and PIUS designs and systems and the planned and off-normal operations are similar enough to current Pressurized Water Reactors (PWR) that RELAP5 safety analysis applicability is unchanged. However, for AP600 the single most important systemic and phenomenological difference between it and current PWRs is in the close coupling between the reactor system and the containment during postulated Loss of Coolant Accident (LOCA) events. This close coupling may require the addition of some thermal-hydraulic models to RELAP5. And for PIUS, the most important new feature is the thermal density locks. These and other important safety-related features are discussed. This document presents general descriptions of RELAP5, AP600, and PIUS, describes the new features and phenomena of the reactors, and discusses the code/reactors safety-related issues. 32 refs., 4 figs., 2 tabs

  1. The Westinghouse AP1000 plant design: a generation III+ reactor with unique proven passive safety technology

    International Nuclear Information System (INIS)

    Demetri, K. J.; Leipner, C. I.; Marshall, M. L.

    2015-09-01

    The AP1000 plant is an 1100-M We pressurized water reactor with passive safety features and extensive plant simplifications and standardization that simplify construction, operation, maintenance, safety, and cost. The AP1000 plant is based on proven pressurized water reactor (PWR) technology, with an emphasis on safety features that rely solely on natural forces. These passive safety features are combined with simple, active, defense-in-depth systems used during normal plant operations which also provide the first level of defense against more probable events. This paper focuses on specific safety and licensing topics: the AP1000 plant robustness to be prepared for extreme events that may lead to catastrophic loss of infrastructure, such as the Fukushima Dai-ichi event, and the AP1000 plant compliance with the safety objectives for new plants. The first deployment of the AP1000 plant formally began in July 2007 when Westinghouse Electric Company and its consortium partner, the Shaw Group, signed contracts for four AP1000 units on coastal sites of Sanmen and Haiyang, China. Both sites have the planned ability to accommodate at least six AP1000 units; construction is largely concurrent for all four units. Additionally, the United States (U.S.) Nuclear Regulatory Commission (NRC) issued combined licenses (COLs) to allow Southern Nuclear Operating Company (SNC) and South Carolina Electric and Gas Company (SCE and G) to construct and operate AP1000 plants. Within this paper, the various factors that contribute to an unparalleled level of design, construction, delivery, and licensing certainty for any new AP1000 plant projects are described. These include: 1) How the AP1000 plant design development and reviews undertaken in the United States, China and Europe increase licensing certainty. 2) How the AP1000 passive plant robustness against extreme events that result in large loss of infrastructure further contributes to the licensing certainty in a post

  2. The Westinghouse AP1000 plant design: a generation III+ reactor with unique proven passive safety technology

    Energy Technology Data Exchange (ETDEWEB)

    Demetri, K. J.; Leipner, C. I.; Marshall, M. L., E-mail: demetrkj@westinghouse.com [Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2015-09-15

    The AP1000 plant is an 1100-M We pressurized water reactor with passive safety features and extensive plant simplifications and standardization that simplify construction, operation, maintenance, safety, and cost. The AP1000 plant is based on proven pressurized water reactor (PWR) technology, with an emphasis on safety features that rely solely on natural forces. These passive safety features are combined with simple, active, defense-in-depth systems used during normal plant operations which also provide the first level of defense against more probable events. This paper focuses on specific safety and licensing topics: the AP1000 plant robustness to be prepared for extreme events that may lead to catastrophic loss of infrastructure, such as the Fukushima Dai-ichi event, and the AP1000 plant compliance with the safety objectives for new plants. The first deployment of the AP1000 plant formally began in July 2007 when Westinghouse Electric Company and its consortium partner, the Shaw Group, signed contracts for four AP1000 units on coastal sites of Sanmen and Haiyang, China. Both sites have the planned ability to accommodate at least six AP1000 units; construction is largely concurrent for all four units. Additionally, the United States (U.S.) Nuclear Regulatory Commission (NRC) issued combined licenses (COLs) to allow Southern Nuclear Operating Company (SNC) and South Carolina Electric and Gas Company (SCE and G) to construct and operate AP1000 plants. Within this paper, the various factors that contribute to an unparalleled level of design, construction, delivery, and licensing certainty for any new AP1000 plant projects are described. These include: 1) How the AP1000 plant design development and reviews undertaken in the United States, China and Europe increase licensing certainty. 2) How the AP1000 passive plant robustness against extreme events that result in large loss of infrastructure further contributes to the licensing certainty in a post

  3. Advanced APS Impacts on Vehicle Payloads

    Science.gov (United States)

    Schneider, Steven J.; Reed, Brian D.

    1989-01-01

    Advanced auxiliary propulsion system (APS) technology has the potential to both, increase the payload capability of earth-to-orbit (ETO) vehicles by reducing APS propellant mass, and simplify ground operations and logistics by reducing the number of fluids on the vehicle and eliminating toxic, corrosive propellants. The impact of integrated cryogenic APS on vehicle payloads is addressed. In this system, launch propulsion system residuals are scavenged from integral launch propulsion tanks for use in the APS. Sufficient propellant is preloaded into the APS to return to earth with margin and noncomplete scavenging assumed. No propellant conditioning is required by the APS, but ambient heat soak is accommodated. High temperature rocket materials enable the use of the unconditioned hydrogen/oxygen in the APS and are estimated to give APS rockets specific impulse of up to about 444 sec. The payload benefits are quantified and compared with an uprated monomethyl hydrazine/nitrogen tetroxide system in a conservative fashion, by assuming a 25.5 percent weight growth for the hydrogen/oxygen system and a 0 percent weight growth for the uprated system. The combination and scavenging and high performance gives payload impacts which are highly mission specific. A payload benefit of 861 kg (1898 lbm) was estimated for a Space Station Freedom rendezvous mission and 2099 kg (4626 lbm) for a sortie mission, with payload impacts varying with the amount of launch propulsion residual propellants. Missions without liquid propellant scavenging were estimated to have payload penalties, however, operational benefits were still possible.

  4. Prospective Internally Controlled Blind Reviewed Clinical Evaluation of Cryolipolysis Combined With Multipolar Radiofrequency andVaripulseTechnology for Enhanced Subject Results in Circumferential Fat Reduction and Skin Laxity of the Flanks.

    Science.gov (United States)

    Few, Julius; Gold, Michael; Sadick, Neil

    2016-11-01

    Increasing demand for non-invasive skin tightening and body contouring procedures has led to several technological in- novations in energy-based devices such as ultrasound, radiofrequency and cryolipolysis. An emerging trend in the eld is to evaluate whether combination therapies for skin laxity/body contouring using energy-based devices can deliver superior clinical results and patient satisfaction. As such, the objective of this prospective, internal-controlled, blind clinical study was to assess the safety and efficacy of cryolipolysis followed by multipolar radiofrequency with pulsed electromagnetic elds (PEMF) and adjustable pulsed suction for the treatment of skin laxity in the flanks. Ten subjects with focal adiposities in the anks were enrolled in the study. All subjects received one session of cryolipolysis treatment and after randomization received two sessions of radiofrequency with PEMF (spaced two weeks apart), followed by another two sessions of radiofrequency with PEMF and adjustable pulsed suction (spaced two weeks apart). Clinical photography was used to monitor the subject's results at baseline, one week, three, and six months post treatment. Blinded reviewers and the treating inves- tigator assessed the clinical outcomes using the Global Aesthetic Improvement (GAI) scale. Side effects were recorded at every visit and patient satisfaction was noted at the one week, three and six-month follow-up using a 5-scale subject satisfaction assessment questionnaire. Analysis of the blinded investigator ratings demonstrated statistical significant enhanced skin laxity mean improvement of 1 grade on the GAI scale in subject treated with the combination treatment (cryolipolysis+RF/PEMF/suction) compared with the cryolipolysis treatment alone. The unblinded investigator GAI ratings also showed enhanced (20%) mean improvement of laxity in the combination treated subjects versus those receiving cryolipolysis alone. Over half of the participants reported

  5. Evaluating Postural Control and Ankle Laxity Between Taping and High-Top Cleats in High School Football Players.

    Science.gov (United States)

    Pizac, Douglas A; Swanik, Charles B; Glutting, Joseph J; Kaminski, Thomas W

    2018-03-01

    Lateral ankle sprains are the most common injuries in high school sports. While ankle taping is a preferred method of external prophylactic support, its restrictive properties decline during exercise. The Under Armour ® Highlight cleat is marketed on the premise that it provides added support without the need for additional ankle taping. To determine if differences in ankle joint laxity and postural control exist between football players wearing the Under Armour ® Highlight cleat (Under Armour Inc, Baltimore, MD) as compared to a low/mid-top cleat with ankle tape. Crossover trial. Athletic training room and football practice field sideline. 32 interscholastic football players (15.8 ± 1.0 y; 178.9 ± 7.4 cm; 87.1 ± 21.4 kg). Ankle laxity was assessed using an instrumented ankle arthrometer (Blue Bay Research Inc, Milton, FL), while postural control testing was performed on the Tekscan MobileMat™ Balanced Error Scoring System (BESS; South Boston, MA). The 2 treatments included Under Armour ® Highlight cleats and a low/mid-top cleat with ankle tape applied to the nondominant ankle only. Measurements were taken before and immediately after practice. The independent variable was treatment (Highlight vs low/mid-top cleat with ankle tape). Dependent variables included ankle arthrometry measures of anterior displacement (mm), inversion/eversion rotation (deg), and the modified BESS error scores. A linear mixed-effects model was used for analysis. The low/mid-top cleat with tape condition had significantly higher inversion range-of-motion (ROM) and inversion/eversion rotation postexercise when compared to the Highlight cleat (P Under Armour ® Highlight cleat restricts ankle ROM following a training session better than the taped low/mid-top cleat. Further study is warranted to determine if this high-top style of football cleat can reduce the incidence of ankle sprains and how it might compare to spat taping.

  6. AP1000 design and construction integration

    International Nuclear Information System (INIS)

    Winters, James W.; Clelland, Jill A.

    2004-01-01

    Construction costs of commercial nuclear generating plants must be reduced in order to expand the future use of nuclear energy. Two of the drivers of plant construction costs are the cost of financing during the construction duration and the substantial amount of skilled craft labor hours needed on site during construction. The application of information technology (IT) has been used to understand and reduce both of these drivers by establishing parallel construction paths using modules and integrating construction sequence review into the design process. In a program sponsored by EPRI, Westinghouse has modeled the construction of AP1000 in '4D' to show its viability, to improve its logic, to improve the plant design for constructibility and overall to reduce time and risk in the construction schedule. The design of most of AP1000 was constrained to be a duplicate of AP600 except where components required expansion for the higher power level. As a result, the construction schedule for AP1000 is as mature and as robust as that for AP600. Two areas important to the construction of AP1000 did require some design work because they could not remain the same as AP1000. First, the turbine building had to be redesigned to accommodate the larger turbine and its support systems. Again, as much of the AP600 design and philosophy as possible was retained. The building required enlargement and the basemat, foundations, steel structure and structural modules required modification. As concrete, steel, and equipment were defined by the designers, they were matched to the original AP600 turbine building schedule. This forced designers to assemble files to be consistent with building assembly activities and to think about constructibility as they defined the final design. Second, the reinforcement structure within the concrete under and supporting the containment vessel required detail design. Westinghouse was fortunate to have the constructor Obayashi of Japan recommend a detailed

  7. AP1000{sup TM} plant modularization

    Energy Technology Data Exchange (ETDEWEB)

    Cantarero L, C.; Demetri, K. J. [Westinghouse Electric Co., 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States); Quintero C, F. P., E-mail: cantarc@westinghouse.com [Westinghouse Electric Spain, Padilla 17, 28006 Madrid (Spain)

    2016-09-15

    The AP1000{sup TM} plant is an 1100 M We pressurized water reactor (PWR) with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance and safety. Modules are used extensively in the design of the AP1000 plant nuclear island. The AP1000 plant uses modern, modular-construction techniques for plant construction. The design incorporates vendor-designed skids and equipment packages, as well as large, multi-ton structural modules and special equipment modules. Modularization allows traditionally sequential construction tasks to be completed simultaneously. Factory-built modules can be installed at the site in a planned construction schedule. The modularized AP1000 plant allows many more construction activities to proceed in parallel. This reduces plant construction calendar time, thus lowering the costs of plant financing. Furthermore, performing less work onsite significantly reduces the amount of skilled field-craft labor, which costs more than shop labor. In addition to labor cost savings, doing more welding and fabrication in a factory environment raises the quality of work, allowing more scheduling flexibility and reducing the amount of specialized tools required onsite. The site layout for the AP1000 plant has been established to support modular construction and efficient operations during construction. The plant layout is compact, using less space than previous conventional plant layouts. This paper provides and overview of the AP1000 plant modules with an emphasis on structural modules. Currently the Westinghouse AP1000 plant has four units under construction in China and four units under construction in the United States. All have shown successful fabrication and installation of various AP1000 plant modules. (Author)

  8. AP1000"T"M plant modularization

    International Nuclear Information System (INIS)

    Cantarero L, C.; Demetri, K. J.; Quintero C, F. P.

    2016-09-01

    The AP1000"T"M plant is an 1100 M We pressurized water reactor (PWR) with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance and safety. Modules are used extensively in the design of the AP1000 plant nuclear island. The AP1000 plant uses modern, modular-construction techniques for plant construction. The design incorporates vendor-designed skids and equipment packages, as well as large, multi-ton structural modules and special equipment modules. Modularization allows traditionally sequential construction tasks to be completed simultaneously. Factory-built modules can be installed at the site in a planned construction schedule. The modularized AP1000 plant allows many more construction activities to proceed in parallel. This reduces plant construction calendar time, thus lowering the costs of plant financing. Furthermore, performing less work onsite significantly reduces the amount of skilled field-craft labor, which costs more than shop labor. In addition to labor cost savings, doing more welding and fabrication in a factory environment raises the quality of work, allowing more scheduling flexibility and reducing the amount of specialized tools required onsite. The site layout for the AP1000 plant has been established to support modular construction and efficient operations during construction. The plant layout is compact, using less space than previous conventional plant layouts. This paper provides and overview of the AP1000 plant modules with an emphasis on structural modules. Currently the Westinghouse AP1000 plant has four units under construction in China and four units under construction in the United States. All have shown successful fabrication and installation of various AP1000 plant modules. (Author)

  9. AP calculus AB & BC crash course

    CERN Document Server

    Rosebush, J

    2012-01-01

    AP Calculus AB & BC Crash Course - Gets You a Higher Advanced Placement Score in Less Time Crash Course is perfect for the time-crunched student, the last-minute studier, or anyone who wants a refresher on the subject. AP Calculus AB & BC Crash Course gives you: Targeted, Focused Review - Study Only What You Need to Know Crash Course is based on an in-depth analysis of the AP Calculus AB & BC course description outline and actual AP test questions. It covers only the information tested on the exams, so you can make the most of your valuable study time. Written by experienced math teachers, our

  10. Westinghouse AP 1000 program status

    International Nuclear Information System (INIS)

    Doehnert, B.

    2002-01-01

    The project 1000 is presented and features are discussed in the paper. Design maturity is characterized by 1300 man-year / $400 million design and testing effort, more than 12 000 design documents completed; 3D computer model developed. It includes structures, equipment, small / large pipe, cable trays, ducts etc. Licensing Maturity is determined by a very thorough and complete NRC review of AP600; 110 man-year effort (NRC) over 6 years, $30 million; independent, confirmatory plant analysis; independent, confirmatory plant testing (ROSA, OSU); over 7400 questions answered, no open items; over 380 meeting with NRC, 43 meetings with ACRS. NRC Design Certification is issued in December 1999. Reasons for developing AP 1000 and design changes are presented. Economic analysis shows an expectation for payback within 20 years. AP1000 provides 75% power uprate for 15% increment in capital cost. AP1000 meets new plant economic targets in the near term

  11. APS Education and Diversity Efforts

    Science.gov (United States)

    Prestridge, Katherine; Hodapp, Theodore

    2015-11-01

    American Physical Society (APS) has a wide range of education and diversity programs and activities, including programs that improve physics education, increase diversity, provide outreach to the public, and impact public policy. We present the latest programs spearheaded by the Committee on the Status of Women in Physics (CSWP), with highlights from other diversity and education efforts. The CSWP is working to increase the fraction of women in physics, understand and implement solutions for gender-specific issues, enhance professional development opportunities for women in physics, and remedy issues that impact gender inequality in physics. The Conferences for Undergraduate Women in Physics, Professional Skills Development Workshops, and our new Professional Skills program for students and postdocs are all working towards meeting these goals. The CSWP also has site visit and conversation visit programs, where department chairs request that the APS assess the climate for women in their departments or facilitate climate discussions. APS also has two significant programs to increase participation by underrepresented minorities (URM). The newest program, the APS National Mentoring Community, is working to provide mentoring to URM undergraduates, and the APS Bridge Program is an established effort that is dramatically increasing the number of URM PhDs in physics.

  12. [Apheresis in antiphospholipid syndrome (APS)].

    Science.gov (United States)

    De Silvestro, Giustina; Tison, Tiziana; Marson, Piero

    2012-01-01

    Antiphospholipid syndrome (APS) is a rare clinical disorder characterized by thromboembolic manifestations and/or obstetric complications. Along with the clinical symptoms and signs, serum antiphospholipid antibodies have to be detected. APS can be primary, i.e., without any concomitant disorders, or secondary to other autoimmune diseases, particularly systemic lupus erythematosus. Criteria for the diagnosis of APS have been clearly established. Hyperacute APS (or catastrophic antiphospholipid syndrome), often with a poor prognosis, must meet four criteria: involvement of three or more organs, rapid evolution of clinical manifestations, microangiopathic occlusion of small blood vessels at biopsy, and presence of antiphospholipid antibodies. The rationale for apheresis treatment is the removal of pathogenetic antibodies involved in the development of tissue damage. Our experience includes 23 patients, in particular 15 women treated for 19 pregnancies. According to the National Guidelines Program, the effectiveness of apheresis in catastrophic syndrome has a level of evidence of V/VI, with a strength of recommendation A; in highrisk pregnancy it has a level of evidence of V with a strength of recommendation B. It will be necessary to better define the prognosis of various categories of pregnant patients with APS, as well as useful laboratory parameters to monitor its clinical course and anticipate any complications of pregnancy.

  13. Imaging features of anterior cruciate ligament reconstruction graft insufficiency

    International Nuclear Information System (INIS)

    Shang Yao; Zhang Yue; Tian Chunyan; Zheng Zhuozhao

    2011-01-01

    Objective: To investigate the imaging features of anterior cruciate ligament (ACL) graft insufficiency. Methods: X-Ray and MR imaging examinations in 24 consecutive patients who had ACL reconstructive graft insufficiency were retrospectively evaluated for tunnel position, osteoarthrosis and its related complications. Follow-up arthroscopy showed 16 graft tears and 8 graft laxities. Fisher exact test was used to compare tunnel malpositions, the proportion of graft tear on MRI and osteoarthrosis between graft tear group and graft laxity group. Results: Two malpositions of tibial tunnel and 3 malpositions of femoral tunnel were seen in graft tear group. Three-malpositions of tibial tunnel and 4 malpositions of femoral tunnel were seen in graft laxity group. The proportion of tibial or femoral malposition showed no significant difference between the two groups (P=0.289, P=0.167). In graft tear group, 15 complete graft tears were diagnosed correctly, 1 partial tear was misdiagnosed as normal on MRI. In graft laxity group, 4 grafts were diagnosed as normal and 4 were considered as graft tear on MRI. A significant difference was seen between the two groups (P=0.028) in the proportion of graft tear diagnosed on MRI. Fourteen osteoarthrosis were seen in graft tear group and 5 in graft laxity group. No significant difference was seen between the two groups (P= 0.289) in the proportion of osteoarthrosis. Conclusion: The proportions of tunnel malposition and osteoarthrosis showed no significant difference between the graft tear group and graft Laxity group. Most graft tears can be diagnosed accurately on MRI, but some cases of graft laxity may be misdiagnosed for graft tear. (authors)

  14. Uncoupling of Obesity from Insulin Resistance Through a Targeted Mutation in aP2, the Adipocyte Fatty Acid Binding Protein

    Science.gov (United States)

    Hotamisligil, Gokhan S.; Johnson, Randall S.; Distel, Robert J.; Ellis, Ramsey; Papaioannou, Virginia E.; Spiegelman, Bruce M.

    1996-11-01

    Fatty acid binding proteins (FABPs) are small cytoplasmic proteins that are expressed in a highly tissue-specific manner and bind to fatty acids such as oleic and retinoic acid. Mice with a null mutation in aP2, the gene encoding the adipocyte FABP, were developmentally and metabolically normal. The aP2-deficient mice developed dietary obesity but, unlike control mice, they did not develop insulin resistance or diabetes. Also unlike their obese wild-type counterparts, obese aP2-/- animals failed to express in adipose tissue tumor necrosis factor-α (TNF-α), a molecule implicated in obesity-related insulin resistance. These results indicate that aP2 is central to the pathway that links obesity to insulin resistance, possibly by linking fatty acid metabolism to expression of TNF-α.

  15. Transcription factor AP-1 in esophageal squamous cell carcinoma: Alterations in activity and expression during Human Papillomavirus infection

    International Nuclear Information System (INIS)

    Hussain, Showket; Bharti, Alok C; Salam, Irfana; Bhat, Mohammad Akbar; Mir, Mohammad Muzaffar; Hedau, Suresh; Siddiqi, Mushtaq A; Basir, Seemi Farhat; Das, Bhudev C

    2009-01-01

    Esophageal squamous cell carcinoma (ESCC) is a leading cause of cancer-related deaths in Jammu and Kashmir (J&K) region of India. A substantial proportion of esophageal carcinoma is associated with infection of high-risk HPV type 16 and HPV18, the oncogenic expression of which is controlled by host cell transcription factor Activator Protein-1 (AP-1). We, therefore, have investigated the role of DNA binding and expression pattern of AP-1 in esophageal cancer with or without HPV infection. Seventy five histopathologically-confirmed esophageal cancer and an equal number of corresponding adjacent normal tissue biopsies from Kashmir were analyzed for HPV infection, DNA binding activity and expression of AP-1 family of proteins by PCR, gel shift assay and immunoblotting respectively. A high DNA binding activity and elevated expression of AP-1 proteins were observed in esophageal cancer, which differed between HPV positive (19%) and HPV negative (81%) carcinomas. While JunB, c-Fos and Fra-1 were the major contributors to AP-1 binding activity in HPV negative cases, Fra-1 was completely absent in HPV16 positive cancers. Comparison of AP-1 family proteins demonstrated high expression of JunD and c-Fos in HPV positive tumors, but interestingly, Fra-1 expression was extremely low or nil in these tumor tissues. Differential AP-1 binding activity and expression of its specific proteins between HPV - positive and HPV - negative cases indicate that AP-1 may play an important role during HPV-induced esophageal carcinogenesis

  16. APS Science 2007.

    Energy Technology Data Exchange (ETDEWEB)

    2008-05-30

    This report provides research highlights from the Advanced Photon Source (APS). Although these highlights represent less than 10% of the published work from the APS in 2007, they give a flavor of the diversity and impact of user research at the facility. In the strategic planning the aim is to foster the growth of existing user communities and foresee new areas of research. This coming year finds the APS engaged in putting together, along with the users, a blueprint for the next five years, and making the case for a set of prioritized investments in beamlines, the accelerator, and infrastructure, each of which will be transformational in terms of scientific impact. As this is written plans are being formulated for an important user workshop on October 20-21, 2008, to prioritize strategic plans. The fruit from past investments can be seen in this report. Examples include the creation of a dedicated beamline for x-ray photon correlation spectroscopy at Sector 8, the evolution of dedicated high-energy x-ray scattering beamlines at sectors 1 and 11, a dedicated imaging beamline at Sector 32, and new beamlines for inelastic scattering and powder diffraction. A single-pulse facility has been built in collaboration with Sector 14 (BioCARS) and Phil Anfinrud at the National Institutes of Health, which will offer exceptionally high flux for single-pulse diffraction. The nanoprobe at Sector 26, built and operated jointly by the Argonne Center for Nanoscale Materials and the X-ray Operations and Research (XOR) section of the APS X-ray Science Division, has come on line to define the state of the art in nanoscience.

  17. APS Science 2007

    International Nuclear Information System (INIS)

    2008-01-01

    This report provides research highlights from the Advanced Photon Source (APS). Although these highlights represent less than 10% of the published work from the APS in 2007, they give a flavor of the diversity and impact of user research at the facility. In the strategic planning the aim is to foster the growth of existing user communities and foresee new areas of research. This coming year finds the APS engaged in putting together, along with the users, a blueprint for the next five years, and making the case for a set of prioritized investments in beamlines, the accelerator, and infrastructure, each of which will be transformational in terms of scientific impact. As this is written plans are being formulated for an important user workshop on October 20-21, 2008, to prioritize strategic plans. The fruit from past investments can be seen in this report. Examples include the creation of a dedicated beamline for x-ray photon correlation spectroscopy at Sector 8, the evolution of dedicated high-energy x-ray scattering beamlines at sectors 1 and 11, a dedicated imaging beamline at Sector 32, and new beamlines for inelastic scattering and powder diffraction. A single-pulse facility has been built in collaboration with Sector 14 (BioCARS) and Phil Anfinrud at the National Institutes of Health, which will offer exceptionally high flux for single-pulse diffraction. The nanoprobe at Sector 26, built and operated jointly by the Argonne Center for Nanoscale Materials and the X-ray Operations and Research (XOR) section of the APS X-ray Science Division, has come on line to define the state of the art in nanoscience

  18. A Comparative Dosimetric Study of Adjuvant 3D Conformal Radiotherapy for Operable Stomach Cancer Versus AP-PA Conventional Radiotherapy in NCI-Cairo

    International Nuclear Information System (INIS)

    El-Hossiny, H.A.; Diab, N.A.; El-Taher, M.M.

    2009-01-01

    This study was to compare this multiple field conformal technique to the AP-PA technique with respect to target volume coverage and dose to normal tissues. Materials and Methods: Seventeen patients with stages II-III denocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy presented to radiotherapy department in National Cancer Institute, Cairo in period between February 2009 to March 2010 using 3D conformal radiotherapy technique that consisted of a mono isocentric arrangement employing 4-6 radiation fields. For each patient, a second radiotherapy treatment plan was done using an antroposterior (AP-PA) fields, the two techniques were then compared using dose volume histogram (DVH) analysis. Results: Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both (3D and 2D) plans while the left kidney and spinal cord demonstrate lower radiation doses on using the conformal technique. The liver doses is higher in the 3D tecq, but still well below liver tolerance. Conclusions: Both 3D conformal radiotherapy and AP-PA conventional techniques doses are within range of normal tissues tolerance. Regarding the left kidney and spinal cord the 3D conformal radiotherapy is superior than the AP-PA conventional techniques but with higher doses to the liver in the 3D conformal radiotherapy compared to the AP-PA conventional techniques

  19. [Traditional risk factors for cardiovascular disease in primary antiphospholipid syndrome (APS) when compared with secondary APS: a study with 96 patients].

    Science.gov (United States)

    Ribeiro, A R; Carvalho, J F

    2010-01-01

    To evaluate the prevalence of traditional risk factors in patients with primary antiphospholipid syndrome (APS) in comparison to those with systemic lupus erythematosus-secondary APS. Transversal study of 96 APS patients (Sapporo's criteria). Demographic and clinical data, cardiovascular risk factors and drug use were investigated. Thirty-nine Primary APS and 57 secondary APS were included. The groups did not differ regarding age (38.5 +/- 9.9 vs. 39.4 +/- 10.5 years, p=0.84) and female gender (84.6 vs. 96.5%, p=0.06), respectively. Arterial events were more observed in primary than secondary APS (59 vs. 36.8%, p=0.04) patients. No difference was seen concerning venous and obstetric events. In regard to traditional risk factors for cardiovascular disease, both groups were comparable related to current or previous smoking, sedentarism, family history for coronary disease, systemic hypertension, diabetes mellitus, overweight and obesity. The frequencies of altered lipid profiles were alike in the two groups, except for a higher prevalence of low HDL-c levels in primary APS group (84.6 vs. 45.5%, p=0.0001). Concerning drug use, no significant differences were observed related to chloroquine and statin use, however the secondary APS patients had a higher rate of prednisone use (10.2 vs. 57.9%, pAPS, except for a high frequency of low HDL-c in primary APS patients.

  20. Assessment of medial elbow laxity by gravity stress radiography: comparison of valgus stress radiography with gravity and a Telos stress device.

    Science.gov (United States)

    Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro

    2014-04-01

    Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  1. Función del diafragma durante la colocación de cargas sobre el abdomen en sujetos normales Study of diaphragmatic muscle function during abdominal weight in normal subjects

    Directory of Open Access Journals (Sweden)

    Sergio G. Monteiro

    2012-04-01

    Full Text Available Los efectos de las cargas en el abdomen con el objeto de producir entrenamiento del diafragma, no han sido suficientemente evaluados. Estudiamos la función del diafragma durante la colocación de cargas sobre el abdomen y con cambios en el patrón respiratorio. Se estudiaron 6 voluntarios normales. Se obtuvo flujo en la boca, presión gástrica (Pga, presión esofágica (Pes, movimiento torácico (TX y abdominal (AB, presión inspiratoria máxima (PImax y presión transdiafragmática media (Pdi y máxima (Pdimax. Se calculó la relación Pdi/Pdimax y el índice tensión-tiempo del diafragma (TTdi. Etapas: patrón normal (PN, patrón abdominal (PA y carga de 1, 2, 4 y 6 kg con PN y PA. El PA fue facilitado por las cargas sobre el abdomen. Solo con 6 kg (PN y PA la Pga a capacidad residual funcional aumentó significativamente (p 0.001. La Pdi siguió a las variaciones de la Pga y aumentó con todos los PA (p The effects of the abdominal weight with the intention of producing training of the diaphragm, have not been sufficiently evaluated. We studied the function of the diaphragm during the abdominal weight training and during associated changes in the respiratory pattern. Six normal volunteers were studied. Flow at the mouth at functional residual capacity (FRC was obtained as well as gastric pressure (Pga, esophageal pressure (Pes, thoracic and abdominal movements, maximal inspiratory pressure and mean and maximal transdiaphragmatic pressure (Pdi and Pdi max. Pdi/Pdimax and the diaphragm tension-time index (TTdi were calculated. Studied steps: normal pattern (NP, abdominal pattern (AP and weight of 1, 2, 4 and 6 kg with NP and AP as well. We found 1 The AP was facilitated by the abdominal weight, 2 Only with 6 kg (NP and AP the Pga at FRC increased significantly (p 0.001, 3 the Pdi followed the variations of the Pga and increased with all the AP (p < 0.001, 4 The index TTdi load reached a value of 0.05 ± 0.02 (p < 0.001. The charges did not

  2. [Type 2 autoimmune polyendocrine syndromes (APS-2)].

    Science.gov (United States)

    Vialettes, Bernard; Dubois-Leonardon, Noémie

    2013-01-01

    Type 2 autoimmune polyendocrine syndromes (APS-2) are the most frequent disorders associating several organ-specific autoimmune diseases. Their high prevalence is due to the fact that the main manifestations of APS-2, such as thyroidal autoimmunity, type 1 diabetes, autoimmune gastric atrophy and vitiligo, are common diseases. APS-2 represents a clinical model that can serve to help unravel the mechanisms underlying autoimmunity. Diagnosis of APS-2 is a challenge for the clinician, especially in poorly symptomatic forms, and may require systematic screening based on measurement of autoantibodies and functional markers.

  3. AP1000 Containment Design and Safety Assessment

    International Nuclear Information System (INIS)

    Wright, Richard F.; Ofstun, Richard P.; Bachere, Sebastien

    2002-01-01

    The AP1000 is an up-rated version of the AP600 passive plant design that recently received final design certification from the US NRC. Like AP600, the AP1000 is a two-loop, pressurized water reactor featuring passive core cooling and passive containment safety systems. One key safety feature of the AP1000 is the passive containment cooling system which maintains containment integrity in the event of a design basis accident. This system utilizes a high strength, steel containment vessel inside a concrete shield building. In the event of a pipe break inside containment, a high pressure signal actuates valves which allow water to drain from a storage tank atop the shield building. Water is applied to the top of the containment shell, and evaporates, thereby removing heat. An air flow path is formed between the shield building and the containment to aid in the evaporation and is exhausted through a chimney at the top of the shield building. Extensive testing and analysis of this system was performed as part of the AP600 design certification process. The AP1000 containment has been designed to provide increased safety margin despite the increased reactor power. The containment volume was increased to accommodate the larger steam generators, and to provide increased margin for containment pressure response to design basis events. The containment design pressure was increased from AP600 by increasing the shell thickness and by utilizing high strength steel. The passive containment cooling system water capacity has been increased and the water application rate has been scaled to the higher decay heat level. The net result is higher margins to the containment design pressure limit than were calculated for AP600 for all design basis events. (authors)

  4. Identification and treatment of APS renal involvement.

    Science.gov (United States)

    Tektonidou, M G

    2014-10-01

    Renal involvement in antiphospholipid syndrome (APS), either primary or systemic lupus erythematosus (SLE)-related APS, includes renal artery stenosis or thrombosis, renal infarction, renal vein thrombosis and a small-vessel vaso-occlusive nephropathy defined as "antiphospholipid antibody (aPL)-associated nephropathy." aPL-associated nephropathy is characterized by acute lesions, thrombotic microangiopathy, and chronic lesions such as fibrous intimal hyperplasia, organizing thrombi with or without recanalization, fibrous occlusions of arteries or arterioles and focal cortical atrophy. Systemic hypertension, hematuria, proteinuria (ranging from mild to nephrotic level) and renal insufficiency represent the major clinical manifestations associated with aPL-associated nephropathy. Similar renal histologic and clinical characteristics have been described among all different groups of patients with positive aPL (primary APS, SLE-related APS, catastrophic APS and SLE/non-APS with positive aPL). In patients with aPL-associated nephropathy lesions in the absence of other causes associated with similar histological characteristics, aPL testing needs to be considered. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Mutations in ap1b1 cause mistargeting of the Na(+/K(+-ATPase pump in sensory hair cells.

    Directory of Open Access Journals (Sweden)

    Rachel Clemens Grisham

    Full Text Available The hair cells of the inner ear are polarized epithelial cells with a specialized structure at the apical surface, the mechanosensitive hair bundle. Mechanotransduction occurs within the hair bundle, whereas synaptic transmission takes place at the basolateral membrane. The molecular basis of the development and maintenance of the apical and basal compartments in sensory hair cells is poorly understood. Here we describe auditory/vestibular mutants isolated from forward genetic screens in zebrafish with lesions in the adaptor protein 1 beta subunit 1 (ap1b1 gene. Ap1b1 is a subunit of the adaptor complex AP-1, which has been implicated in the targeting of basolateral membrane proteins. In ap1b1 mutants we observed that although the overall development of the inner ear and lateral-line organ appeared normal, the sensory epithelium showed progressive signs of degeneration. Mechanically-evoked calcium transients were reduced in mutant hair cells, indicating that mechanotransduction was also compromised. To gain insight into the cellular and molecular defects in ap1b1 mutants, we examined the localization of basolateral membrane proteins in hair cells. We observed that the Na(+/K(+-ATPase pump (NKA was less abundant in the basolateral membrane and was mislocalized to apical bundles in ap1b1 mutant hair cells. Accordingly, intracellular Na(+ levels were increased in ap1b1 mutant hair cells. Our results suggest that Ap1b1 is essential for maintaining integrity and ion homeostasis in hair cells.

  6. Raising the acceptance of the AP2-line

    International Nuclear Information System (INIS)

    Trbojevic, D.

    1989-01-01

    The 120 GeV Main Ring proton beam collides with the target at the end of the AP-1 line and creates antiprotons and other secondary particles. The AP-2 line transfers the negative particles from the target to the Debuncher. To provide a bigger antiproton stack size in the Accumulator, both the Debuncher as well as the AP-2 line acceptance have to be raised. This is a proposal for the improvement of the AP-2 line acceptance. The first part of the memo presents an acceptance examination of the existing AP-2 line by computer simulation, while the second presents a short proposal for aperture corrections. The computer program TURTLE was used to trace antiprotons through the AP-2 line without taking into account other negative charged particles. Betatron functions were obtained from the output of the SYNCH computer program. The SYNCH program was also used to check the dispersion match between the AP-2 line and the Debuncher. 3 refs., 6 figs., 5 tabs

  7. Comparison of Spectral and Scintillation Properties of LuAP:Ce and LuAP:Ce,Sc Single Crystals

    Science.gov (United States)

    Petrosyan, Ashot G.; Derdzyan, Marina; Ovanesyan, Karine; Shirinyan, Grigori; Lecoq, Paul; Auffray, Etiennette; Kronberger, Matthias; Frisch, Benjamin; Pedrini, Christian; Dujardin, Christophe

    2009-10-01

    Scintillation properties of LuAP:Ce and LuAP:Ce,Sc crystal series were studied under excitation by gamma-rays from a 137Cs source. Both series demonstrated comparable optical quality in terms of underlying absorption at 260 nm, slope of the optical edge and transmission in the range of emission. The light yield of LuAP:Ce crystals measured in 0.2 cm times 0.2 cm times 0.8 cm pixels increases linearly with the Ce concentration reaching at 0.58 at. % 6448 plusmn 322 ph/MeV and 9911 plusmn 496 ph/MeV in the long and in the short directions respectively (the light yield ratio is 65%) and shows no sign of light saturation. The energy resolution is found to depend, among other factors, on the uniformity of Ce concentration within the pixels and is improved to 7.1 plusmn 0.4% (I = 0.2 cm), 9.5 plusmn 0.5% (I = 0.8 cm). Intentional co-doping with Sc + ions was tested and resulted in increase of the Ce distribution coefficient to about 0.3. This enabled to increase the concentration of Ce in LuAP:Ce,Sc crystals up to 0.7 at. %, while conserving high optical quality. In contrast to LuAP:Ce, the light yield in LuAP:Ce,Sc crystals does not increase with Ce concentration, the photo peak being gradually suppressed. The involved mechanisms are discussed basing on measurements of the unit cell volumes, Ce concentration uniformity, x-ray rocking spectra, absorption spectra of pure and variously doped LuAP crystals, and emission spectra under different excitations.

  8. Suggestion on Information Sharing for AP implementation

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hye Won; Kim, Min Su; Koh, Byung Marn [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2013-10-15

    Under the Additional Protocol, States should provide the IAEA with expanded declarations of activities related to the nuclear fuel cycle and other nuclear activities, and with expanded access to the relevant information and sites to allow the IAEA to verify the completeness of these declarations. The AP to the Safeguards Agreement (the Additional Protocol) was signed on June 21{sup st}, 1999 and entered into force on February 19{sup th}, 2004. ROK submitted initial declarations in August 2004. Since then, ROK has been submitting annual updated reports of initial declaration on every May 15{sup th}. To achieve successful implementation, it is necessary to collect the information for each individual article in Article 2 of the AP and verify the declared information provided by facility operators. Therefore, the cooperation among the ministries and offices concerned is a prerequisite for successful implementation of AP. Unfortunately, the formal procedure for inter-organizational information sharing and cooperation is not established. This paper will briefly outline the AP declarations and suggest the information sharing among the ministries, offices and organizations for effective and efficient implementation of AP. The State authority has responsibility for AP implementation and it should verify correctness and completeness of the information declared by facility operators before submitting the declarations. The close cooperation and information sharing among the ministries, offices and organizations are indispensable to effective and efficient implementation of AP.

  9. Rotational Evolution and Magnetic Field of AP Stars

    Science.gov (United States)

    Xiaojun, C.; Matsuura, O. T.

    1990-11-01

    RESUMO. Prop6e- se qLie 0 campo de estrelas Ap pode ser 9cr ado pelo mecanismo de na base clo envelope c 0 fl V C C t V 0, C t r a ri S p 0 r t a d C) p a r a a S LI p e r f C 1 e p e I a Instabllidade de boiament 0 na ase de Haya hi. Campos cibservados permit em est imar uma perda de momento durante a ase pr -Seque%nC:ia P r ri C: p a I a ci ni p a t V C I C: C) m a s C) b s e r V a nT C 5. E S t r C I a S A normals, que ro t a ao , ria0 most ram camp Os :os superficia; importantes e isto pode ac:oriteaer C LIma protoestrela evolue para Sequencia Principal em passar pela fase de Hayashi. ABSTRACT: It 5 proposed that the ma9netic field o Ap stars may be enerated by the dynamo at the base of the convective envelope, arid transported to the surface b y t h C i ri s t a b iii t y C) f b LI 0 y a n c y i n t h C H a y a s hi p h a s e. Observed surface ma9netic fields allow to estimate a 1055 of an9ular momentum during the pre-Main Sequence phase compatible with the observations. apidIy rotating normal A stars do not shciw important surface magnetic fields and this may occur if a protostar evcilves to Main Sequence skipping the Hayashi phase. Key words: HYDROMAGNETICS - STARS-PECULIAR A

  10. Operation of the APS rf gun

    International Nuclear Information System (INIS)

    Lewellen, J. W.

    1998-01-01

    The Advanced Photon Source (APS) has a thermionic-cathode rf gun system capable of providing beam to the APS linac. The gun system consists of a 1.6-cell thermionic-cathode rf gun, a fast kicker for beam current control, and an alpha magnet for bunch compression and injection into the APS linac line. This system is intended for use both as an injector for positron creation, and as a first beam source for the Low-Energy Undulator Test Line (LEUTL) project [1]. The first measured performance characteristics of the gun are presented.

  11. The Ped-APS Registry: the antiphospholipid syndrome in childhood.

    Science.gov (United States)

    Avcin, T; Cimaz, R; Rozman, B

    2009-09-01

    In recent years, antiphospholipid syndrome (APS) has been increasingly recognised in various paediatric autoimmune and nonautoimmune diseases, but the relatively low prevalence and heterogeneity of APS in childhood made it very difficult to study in a systematic way. The project of an international registry of paediatric patients with APS (the Ped-APS Registry) was initiated in 2004 to foster and conduct multicentre, controlled studies with large number of paediatric APS patients. The Ped-APS Registry is organised as a collaborative project of the European Forum on Antiphospholipid Antibodies and Juvenile Systemic Lupus Erythematosus Working Group of the Paediatric Rheumatology European Society. Currently, it documents a standardised clinical, laboratory and therapeutic data of 133 children with antiphospholipid antibodies (aPL)-related thrombosis from 14 countries. The priority projects for future research of the Ped-APS Registry include prospective enrollment of new patients with aPL-related thrombosis, assessment of differences between the paediatric and adult APS, evaluation of proinflammatory genotype as a risk factor for APS manifestations in childhood and evaluation of patients with isolated nonthrombotic aPL-related manifestations.

  12. The first photon shutter development for APS insertion device beamline front ends

    International Nuclear Information System (INIS)

    Shu, Deming; Nian, H.L.T.; Wang, Zhibi; Collins, J.T.; Ryding, D.G.; Kuzay, T.M.

    1992-01-01

    One of the most critical components on the Advanced Photon Source (APS) insertion device (ID) beamline front ends is the first photon shutter. It operates in two modes to fully intercept the high total power and high-heat flux ID photon beam in seconds (normal mode) or in less than 100 ms (emergency fast mode). It is designed to operate in ultra high vacuum (UHV). The design incorporates a multi-channel rectangular bar, bent in a ''hockey stick'' configuration, with two-point suspension. The flanged end is an articulated bellows with rolling hinges. The actuation end is a spring-assisted, pneumatic fail-safe flexural pivot type. The coolant (water) channels incorporate brazed copper foam to enhance the heat transfer, a tube technology particular to the APS. The design development, and material aspects, as well as the extensive thermal and vibrational analyses in support of the design, are presented in this paper

  13. Spent fuel pool spray cooling system for the AP1000 {sup registered}

    Energy Technology Data Exchange (ETDEWEB)

    Vujic, Zoran; Sassen, Felix; Tietsch, Wolfgang [Westinghouse Electric Germany GmbH, Mannheim (Germany)

    2013-07-01

    The AP1000 {sup registered} plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for Design Basis Events and Beyond Design Basis Accidents (BDBA). The AP1000 {sup registered} plant lines of defense with respect to Spent Fuel Pool (SFP) cooling are as follows: 1. During normal and abnormal conditions, defense-in-depth and duty systems provide highly reliable SFP cooling, supplied by offsite AC power or the onsite Standby Diesel Generators. 2. For unlikely events with extended loss of AC power (i.e. station black-out) and/or loss of heat sink, spent fuel cooling can be still provided indefinitely by: 2a. Passive systems, requiring minimal or no operator actions, sufficient for at least 72 hours under all possible loading conditions. 2b. After 3 days, several different means are provided to continue SFP cooling using installed plant equipment as well as off-site equipment with built-in connections. 3. Even for BDBA with postulated SFP damage and multiple failures in the passive safety-related systems and in the defense-in-depth active systems, the AP1000 {sup registered} SFP Spray System provides an additional line of defense to prevent spent fuel damage. (orig.)

  14. Effect of oxygen and nitroaromatic cell radiosensitizers on radiation-induced cleavage of internucleotide bonds: ApA, dApA, and poly(A)

    International Nuclear Information System (INIS)

    Raleigh, J.A.; Kremers, W.; Whitehouse, R.

    1975-01-01

    Irradiation of the dinucleoside monophosphates ApA and dApA in deoxygenated solution leads to a preferential cleavage of the 3' end of the internucleotide bond. Cleavage at the 3' bond is favored to the extent of 2 to 1 over 5' cleavage. Oxygen and nitroaromatic compounds inhibit 3' bond breaking in ApA and dApA in agreement with earlier findings from studies of 3'- and 5'-mononucleotides. In contrast to the mononucleotide results, no enhancement of 5' cleavage is observed for ApA and dApA irradiated in the presence of oxygen or the nitroaromatic additives. The over-all effect of the additives is to decrease the combined (3' and 5') yield of internucleotide bond breaking in ApA and dApA. This phenomenon is also observed for polyadenylic acid in the presence of the nitroaromatics. Oxygen marginally enhances internucleotide bond breaking in polyadenylic acid (factor 1.1) over that seen in deoxygenated solution. Postirradiation alkaline hydrolysis of dApA leads to further ester cleavage revealing the presence of radiation-induced alkali-labile bonds. The number of these bonds decreases in the order oxygen greater than nitrofurans greater than nitrobenzenes approximately irradiation in the absence of additives

  15. APS beamline standard components handbook

    International Nuclear Information System (INIS)

    Kuzay, T.M.

    1992-01-01

    It is clear that most Advanced Photon Source (APS) Collaborative Access Team (CAT) members would like to concentrate on designing specialized equipment related to their scientific programs rather than on routine or standard beamline components. Thus, an effort is in progress at the APS to identify standard and modular components of APS beamlines. Identifying standard components is a nontrivial task because these components should support diverse beamline objectives. To assist with this effort, the APS has obtained advice and help from a Beamline Standardization and Modularization Committee consisting of experts in beamline design, construction, and operation. The staff of the Experimental Facilities Division identified various components thought to be standard items for beamlines, regardless of the specific scientific objective of a particular beamline. A generic beamline layout formed the basis for this identification. This layout is based on a double-crystal monochromator as the first optical element, with the possibility of other elements to follow. Pre-engineering designs were then made of the identified standard components. The Beamline Standardization and Modularization Committee has reviewed these designs and provided very useful input regarding the specifications of these components. We realize that there will be other configurations that may require special or modified components. This Handbook in its current version (1.1) contains descriptions, specifications, and pre-engineering design drawings of these standard components. In the future, the APS plans to add engineering drawings of identified standard beamline components. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction

  16. AP English language & composition crash course

    CERN Document Server

    Hogue, Dawn

    2012-01-01

    AP English Language & Composition Crash Course - Gets You a Higher Advanced Placement Score in Less Time Crash Course is perfect for the time-crunched student, the last-minute studier, or anyone who wants a refresher on the subject. AP English Language & Composition Crash Course gives you: Targeted, Focused Review - Study Only What You Need to Know Crash Course is based on an in-depth analysis of the AP English Language & Composition course description outline and actual Advanced Placement test questions. It covers only the information tested on the exam, so you can make the most of your valua

  17. Religião, política e ordem social nos Atos Apócrifos dos Apóstolos

    Directory of Open Access Journals (Sweden)

    José Adriano Filho

    2016-01-01

    Full Text Available Os Atos Apócrifos dos Apóstolos recontam a tradição dos apóstolos e suas façanhas públicas. Os apóstolos são apresentados em constante conflito com o mundo à sua volta. Eles demonstram o poder do único Deus verdadeiro por meio de milagres, ascetismo e martírio. O cristianismo que eles representam contrasta com as crenças e poder do mundo greco-romano. Esta instância antissocial é reforçada pela mensagem de castidade anunciada pelos apóstolos, a qual interrompe o casamento, e nos conflitos com as autoridades civis e religiosas. Eles têm preocupações apologéticas, missionárias e de edificação, mas rejeitam os ideais culturais e sociais tradicionais em favor de novos ideais. Os Atos Apócrifos também refletem a rede do patronato social e político contemporâneo do Império romano. Eles redefinem o patronato de uma perspectiva cristã e desafiam o sistema estabelecido ao apresentar a Cristo como o verdadeiro patrono, superior aos patronos humanos, incluindo o imperador. A tentativa de reformular as pressuposições estabelecidas é uma característica que define a identidade cristã representada nesta literatura.

  18. Normal and pathological NMR imaging aspects of the posterolateral corner (PLC) of the knee

    International Nuclear Information System (INIS)

    Tardieu, M.; Lazennec, J.Y.; Christel, P.; Brasseur, J.L.; Roger, B.; Grenier, P.

    1995-01-01

    The purpose of the study is to compare normal PLC (limits lateral condyle anterior sub luxation) anatomy and its magnetic resonance imaging (MRI) appearance, with the various lesions observed in MRI, from the simple popliteus tendinous contusion to the complete PLC rupture. For this specific work on PLC lesions, we selected 61 examinations among the traumatic knees explored during the last 3 years. Surgical correlation is obtained for the 61 patients. MRI examinations are performed on a 0.5 T. unit. Normal PLC anatomy is compared to the dissection of 4 anatomic subjects. Normal MRI slices are evaluated with this reference analysis. The principle anatomical structures of the PLC include the lateral collateral ligament, the popliteus tendon, the arcuate ligament, the fabello fibular ligament, the posterolateral condylar capsule, and the posterior horn of the lateral meniscus. Surgical findings confirm PLC lesion for 58 patients with 3 false positive. Diagnosis of these lesions is important because chronical posterolateral laxity is secondary to the destabilization of lateral condyle. Unrecognized and untreated posterolateral instability may result in failure of ACL (limits lateral condyle posterior sub-luxation) reconstruction. When clinical tests are doubtful or complex, or the examination very painful, MRI evaluates completely the traumatic knee and particularly the PLC. (authors). 3 refs., 26 figs

  19. Proactive AP Selection Method Considering the Radio Interference Environment

    Science.gov (United States)

    Taenaka, Yuzo; Kashihara, Shigeru; Tsukamoto, Kazuya; Yamaguchi, Suguru; Oie, Yuji

    In the near future, wireless local area networks (WLANs) will overlap to provide continuous coverage over a wide area. In such ubiquitous WLANs, a mobile node (MN) moving freely between multiple access points (APs) requires not only permanent access to the Internet but also continuous communication quality during handover. In order to satisfy these requirements, an MN needs to (1) select an AP with better performance and (2) execute a handover seamlessly. To satisfy requirement (2), we proposed a seamless handover method in a previous study. Moreover, in order to achieve (1), the Received Signal Strength Indicator (RSSI) is usually employed to measure wireless link quality in a WLAN system. However, in a real environment, especially if APs are densely situated, it is difficult to always select an AP with better performance based on only the RSSI. This is because the RSSI alone cannot detect the degradation of communication quality due to radio interference. Moreover, it is important that AP selection is completed only on an MN, because we can assume that, in ubiquitous WLANs, various organizations or operators will manage APs. Hence, we cannot modify the APs for AP selection. To overcome these difficulties, in the present paper, we propose and implement a proactive AP selection method considering wireless link condition based on the number of frame retransmissions in addition to the RSSI. In the evaluation, we show that the proposed AP selection method can appropriately select an AP with good wireless link quality, i.e., high RSSI and low radio interference.

  20. Global coupling and decoupling of the APS storage ring

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Y.C.; Liu, J.; Teng, L.C.

    1993-07-01

    This paper describes a study of controlling the coupling between the horizontal and the vertical betatron oscillations in the 7-GeV Advanced Photon Source (APS) storage ring. First, we investigate the strengthening of coupling using two families of skew quadrupoles. Twenty skew quadrupoles are arranged in the 40 sectors of the storage ring and powered in such a way so as to generate both quadrature components of the required 21st harmonic. The numerical results from tracking a single particle are presented for the various configurations of skew quadrupoles. Second, we describe the global decoupling procedure to minimize the unwanted coupling effects. These are mainly due to the random roll errors of normal quadruples. It is shown that even with the rather large rms roll error of 2 mrad, the coupling effects can be compensated for with 20 skew quadrupoles each having maximum strength one order of magnitude lower than the typical normal quadrupole strength.

  1. Westinghouse AP1000 advanced passive plant: design features and benefits

    International Nuclear Information System (INIS)

    Walls, S.J.; Cummins, W.E.

    2003-01-01

    The Westinghouse AP1000 Program is aimed at implementing the AP1000 plant to provide a further major improvement in plant economics while maintaining the passive safety advantages established by the AP600. An objective is to retain to the maximum extent possible the plant design of the AP600 so as to retain the licensing basis, cost estimate, construction schedule, modularization scheme, and the detailed design from the AP600 program. Westinghouse and the US Nuclear Regulatory Commission staff have embarked on a program to complete Design Certification for the AP1000 by 2004. A pre-certification review phase was completed in March 2002 and was successful in establishing the applicability of the AP600 test program and AP600 safety analysis codes to the AP1000 Design Certification. On March 28, 2002, Westinghouse submitted to US NRC the AP1000 Design Control Document and Probabilistic Risk Assessment, thereby initiating the formal design certification review process. The results presented in these documents verify the safety performance of the API 000 and conformance with US NRC licensing requirements. Plans are being developed for implementation of a series of AP1000 plants in the US. Key factors in this planning are the economics of AP1000, and the associated business model for licensing, constructing and operating these new plants. Similarly plans are being developed to get the AP1000 design reviewed for use in the UK. Part of this planning has been to examine the AP1000 design relative to anticipated UK safety and licensing issues. (author)

  2. Hepatitis C virus induces E6AP-dependent degradation of the retinoblastoma protein.

    Directory of Open Access Journals (Sweden)

    Tsubasa Munakata

    2007-09-01

    Full Text Available Hepatitis C virus (HCV is a positive-strand RNA virus that frequently causes persistent infections and is uniquely associated with the development of hepatocellular carcinoma. While the mechanism(s by which the virus promotes cancer are poorly defined, previous studies indicate that the HCV RNA-dependent RNA polymerase, nonstructural protein 5B (NS5B, forms a complex with the retinoblastoma tumor suppressor protein (pRb, targeting it for degradation, activating E2F-responsive promoters, and stimulating cellular proliferation. Here, we describe the mechanism underlying pRb regulation by HCV and its relevance to HCV infection. We show that the abundance of pRb is strongly downregulated, and its normal nuclear localization altered to include a major cytoplasmic component, following infection of cultured hepatoma cells with either genotype 1a or 2a HCV. We further demonstrate that this is due to NS5B-dependent ubiquitination of pRb and its subsequent degradation via the proteasome. The NS5B-dependent ubiquitination of pRb requires the ubiquitin ligase activity of E6-associated protein (E6AP, as pRb abundance was restored by siRNA knockdown of E6AP or overexpression of a dominant-negative E6AP mutant in cells containing HCV RNA replicons. E6AP also forms a complex with pRb in an NS5B-dependent manner. These findings suggest a novel mechanism for the regulation of pRb in which the HCV NS5B protein traps pRb in the cytoplasm, and subsequently recruits E6AP to this complex in a process that leads to the ubiquitination of pRb. The disruption of pRb/E2F regulatory pathways in cells infected with HCV is likely to promote hepatocellular proliferation and chromosomal instability, factors important for the development of liver cancer.

  3. Comportamento da eosinofilia após o tratamento das geohelmintoses

    Directory of Open Access Journals (Sweden)

    Marta Maria Bozóti

    1973-04-01

    Full Text Available A eosinofilia sanguínea após o tratamento anti-helmíntico específico se comportou numa amostragem de 57 crianças da seguinte forma: .Na ascaridíase isolada ou associada à trieuríase a hipereosinofilia parasitária ou descia uniformemente após o tratamento, ou houve primeiro uma exacerbação que durava até a terceira semana após a erradicação da, parasitose, descendo em seguida. Em ambos os casos houve normalização do hemograma em dois meses. Na associação ascaridíase/ancilostomíase também são possíveis dois tipos de comportamento da eosinofilia após tratamento eficaz: ou vai diminuindo a hipereosinofilia, logo em seguida à expulsão dos parasitos, ou há no primeiro mês um aumento da hipereosinofilia (geralmente mais acentuado na primeira semana que se segue ao tratamento, para diminuir após o fim do primeiro mês progressivamente até desaparecer. Na estrongiloidíase e na associação ascaridíase/estrongiloidíase há diminuição constante da hipereosinofilia logo após o tratamento e o hemograma se normaliza em cerca de dois meses. Na trieuríase, a hipereosinofilia, aliás já discreta, diminui pouco com o tratamento. Na ancilostomíase e na associação ancilostomíase/trieuríase a hipereosinofilia ou desce após o tratamento gradativo e lentamente, ou primeiro há uma exaltação temporária nas primeiras três semanas após a terapêutica, para diminuir em seguida. Na associação ancilostomíase/estrongiloidíase também se encontram esses dois tipos de comportamento da hipereosinofilia verminótica, mas a exacerbação da hipereosinofilia, que ocorre na metade dos casos, só dura duas semanas; a regressão eosinofílica ocorre dois meses após o tratamento. Nas tri e tetraeparasitoses a involução pós-terapêutica da hipereosinofilia é irregular e a normalização das taxas sanguíneas de eosinófilos é sempre arrastada, principalmente nas associações ascaridíase/estrongiloidíase/ancilostomíase e

  4. Market analysis of APS/SCM applications and technologies

    OpenAIRE

    Prášil, Zdeněk

    2009-01-01

    The bachelor thesis aims to describe a current worldwide market of APS/SCM technologies and applications , i.e. advanced planned scheduling /supply chain management. In the first part, the APS/SCM is described in theory. The APS/SCM is defined and its benefits and impacts on company are discussed. The next part of the work is focused on the market with APS/SCM and the distribution of forces in the market. The demand and supply of this market segment is analyzed. In the last part, solutions of...

  5. AP Human Geography and Success on the AP Test

    Science.gov (United States)

    Roncone, John; Newhalfen, Nate

    2013-01-01

    Classroom projects that explore culture and globalization enhance the curriculum and help students see how geography directly connects to their lives. These authors contend that a project-based approach can supplement the teaching of an AP Human Geography course, and visualize this course as an essential tool for students to truly understand how…

  6. Treating multiple body parts for skin laxity and fat deposits using a novel focused radiofrequency device with an ultrasound component: Safety and efficacy study.

    Science.gov (United States)

    Chilukuri, Suneel; Denjean, Dominique; Fouque, Linda

    2017-12-01

    Growing demand for noninvasive skin tightening and reduction in fat results in an increasing pressure for devices with good clinical efficacy, consistency of results, and high patient comfort. The objective was to validate clinical efficacy and versatility of a novel device, which combines radiofrequency (RF) and ultrasound for treating skin laxity and fat deposits. We treated 34 subjects with facial skin laxity and/or abundant body or arm fat deposits. Subjects were divided based on their indications. Ten subjects received treatments to the face, 7 subjects to arms, 8 subjects to thighs, and 9 subjects on abdomen. All patients received 4 treatments on a weekly basis. Photographs of patients were assessed by blinded evaluators to recognize the baseline images from the 3-month follow-up images. Patient comfort and satisfaction were evaluated using a 5-point Likert scale questionnaire. Any adverse events were recorded. Patient images were correctly recognized in >90% of cases in all study groups. Patient questionnaires showed overall satisfaction with the therapy course and results. On a scale of 1 to 5, the patients agreed (4.1) that they are satisfied with the results that the treatment is comfortable (4.1) and that they are satisfied with the treatment time (4.1). No adverse events were reported. Consistent clinical efficacy was confirmed across all the treated areas, together with high patient comfort and satisfaction. We conclude the device is a highly versatile solution that can deliver results across body parts and different indications. © 2017 The Authors Journal of Cosmetic Dermatology Published by Wiley Periodicals, Inc.

  7. Westinghouse AP600 advanced nuclear plant design

    International Nuclear Information System (INIS)

    Gangloff, W.

    1999-01-01

    As part of the cooperative US Department of Energy (DOE) Advanced Light Water Reactor (ALWR) Program and the Electric Power Research Institute (EPRI), the Westinghouse AP600 team has developed a simplified, safe, and economic 600-megawatt plant to enter into a new era of nuclear power generation. Designed to satisfy the standards set by DOE and defined in the ALWR Utility Requirements Document (URD), the Westinghouse AP600 is an elegant combination of innovative safety systems that rely on dependable natural forces and proven technologies. The Westinghouse AP600 design simplifies plant systems and significant operation, inspections, maintenance, and quality assurance requirements by greatly reducing the amount of valves, pumps, piping, HVAC ducting, and other complex components. The AP600 safety systems are predominantly passive, depending on the reliable natural forces of gravity, circulation, convection, evaporation, and condensation, instead of AC power supplies and motor-driven components. The AP600 provides a high degree of public safety and licensing certainty. It draws upon 40 years of experience in light water reactor components and technology, so no demonstration plant is required. During the AP600 design program, a comprehensive test program was carried out to verify plant components, passive safety systems components, and containment behavior. When the test program was completed at the end of 1994, the AP600 became the most thoroughly tested advanced reactor design ever reviewed by the US Nuclear Regulatory Commission (NRC). The test results confirmed the exceptional behavior of the passive systems and have been instrumental in facilitating code validations. Westinghouse received Final Design Approval from the NRC in September 1998. (author)

  8. NF-κB/AP-1-Targeted Inhibition of Macrophage-Mediated Inflammatory Responses by Depigmenting Compound AP736 Derived from Natural 1,3-Diphenylpropane Skeleton

    Directory of Open Access Journals (Sweden)

    Van Thai Ha

    2014-01-01

    Full Text Available AP736 was identified as an antimelanogenic drug that can be used for the prevention of melasma, freckles, and dark spots in skin by acting as a suppressor of melanin synthesis and tyrosinase expression. Since macrophage-mediated inflammatory responses are critical for skin health, here we investigated the potential anti-inflammatory activity of AP736. The effects of AP736 on various inflammatory events such as nitric oxide (NO/prostaglandin (PG E2 production, inflammatory gene expression, phagocytic uptake, and morphological changes were examined in RAW264.7 cells. AP736 was found to strongly inhibit the production of both NO and PGE2 in lipopolysaccharide- (LPS- treated RAW264.7 cells. In addition, AP736 strongly inhibited both LPS-induced morphological changes and FITC-dextran-induced phagocytic uptake. Furthermore, AP736 also downregulated the expression of multiple inflammatory genes, such as inducible NO synthase (iNOS, cyclooxygenase- (COX- 2, and interleukin- (IL- 1β in LPS-treated RAW264.7 cells. Transcription factor analysis, including upstream signalling events, revealed that both NF-κB and AP-1 were targeted by AP736 via inhibition of the IKK/IκBα and IRAK1/TAK1 pathways. Therefore, our results strongly suggest that AP736 is a potential anti-inflammatory drug due to its suppression of NF-κB-IKK/IκBα and AP-1-IRAK1/TAK1 signalling, which may make AP736 useful for the treatment of macrophage-mediated skin inflammation.

  9. K-AP: Generating specified K clusters by efficient Affinity Propagation

    KAUST Repository

    Zhang, Xiangliang; Wang, Wei; Nø rvå g, Kjetil; Sebag, Michè le

    2010-01-01

    and experimental validation, K-AP was shown to be able to directly generate K clusters as user defined, with a negligible increase of computational cost compared to AP. In the meanwhile, K-AP preserves the clustering quality as AP in terms of the distortion. K

  10. OpenAPS Data Commons on Open Humans

    OpenAIRE

    Lewis, Dana M.; Ball, Madeleine

    2017-01-01

    Poster describing OpenAPS, Open Humans, and joint work creating a data commons for OpenAPS data in the Open Humans platform. Presented at the 2017 Sage Assembly Bionetworks Assembly and recipient of a Young Innovator/Investigator award.

  11. AP1000, a nuclear central of advanced design

    International Nuclear Information System (INIS)

    Hernandez M, N.; Viais J, J.

    2005-01-01

    The AP1000 is a design of a nuclear reactor of pressurized water (PWR) of 1000 M We with characteristic of safety in a passive way; besides presenting simplifications in the systems of the plant, the construction, the maintenance and the safety, the AP1000 is a design that uses technology endorsed by those but of 30 years of operational experience of the PWR reactors. The program AP1000 of Westinghouse is focused to the implementation of the plant to provide improvements in the economy of the same one and it is a design that is derived directly of the AP600 designs. On September 13, 2004 the US-NRC (for their initials in United States- Nuclear Regulatory Commission) approved the final design of the AP1000, now Westinghouse and the US-NRC are working on the whole in a complete program for the certification. (Author)

  12. ONLINE MINIMIZATION OF VERTICAL BEAM SIZES AT APS

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yipeng

    2017-06-25

    In this paper, online minimization of vertical beam sizes along the APS (Advanced Photon Source) storage ring is presented. A genetic algorithm (GA) was developed and employed for the online optimization in the APS storage ring. A total of 59 families of skew quadrupole magnets were employed as knobs to adjust the coupling and the vertical dispersion in the APS storage ring. Starting from initially zero current skew quadrupoles, small vertical beam sizes along the APS storage ring were achieved in a short optimization time of one hour. The optimization results from this method are briefly compared with the one from LOCO (Linear Optics from Closed Orbits) response matrix correction.

  13. K-AP: Generating specified K clusters by efficient Affinity Propagation

    KAUST Repository

    Zhang, Xiangliang

    2010-12-01

    The Affinity Propagation (AP) clustering algorithm proposed by Frey and Dueck (2007) provides an understandable, nearly optimal summary of a data set. However, it suffers two major shortcomings: i) the number of clusters is vague with the user-defined parameter called self-confidence, and ii) the quadratic computational complexity. When aiming at a given number of clusters due to prior knowledge, AP has to be launched many times until an appropriate setting of self-confidence is found. The re-launched AP increases the computational cost by one order of magnitude. In this paper, we propose an algorithm, called K-AP, to exploit the immediate results of K clusters by introducing a constraint in the process of message passing. Through theoretical analysis and experimental validation, K-AP was shown to be able to directly generate K clusters as user defined, with a negligible increase of computational cost compared to AP. In the meanwhile, K-AP preserves the clustering quality as AP in terms of the distortion. K-AP is more effective than k-medoids w.r.t. the distortion minimization and higher clustering purity. © 2010 IEEE.

  14. Precaval retropancreatic space: Normal anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yeon Hee; Kim, Ki Whang; Kim, Myung Jin; Yoo, Hyung Sik; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1992-07-15

    The authors defined precaval retropancreatic space as the space between pancreatic head with portal vein and IVC and analyzed the CT findings of this space to know the normal structures and size in this space. We evaluated 100 cases of normal abdominal CT scan to find out normal anatomic structures of precaval retropancreatic space retrospectively. We also measured the distance between these structures and calculated the minimum, maximum and mean values. At the splenoportal confluence level, normal structures between portal vein and IVC were vessel (21%), lymph node (19%), and caudate lobe of liver (2%) in order of frequency. The maximum AP diameter of portocaval lymph node was 4 mm. Common bile duct (CBD) was seen in 44% and the diameter was mean 3 mm and maximum 11 mm. CBD was located in extrapancreatic (75%) and lateral (60.6%) to pancreatic head. At IVC-left renal vein level, the maximum distance between CBD and IVC was 5 mm and the structure between posterior pancreatic surface and IVC was only fat tissue. Knowledge of these normal structures and measurement will be helpful in differentiating pancreatic mass with retropancreatic mass such as lymphadenopathy.

  15. Advanced Photon Source (APS)

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Photon Source (APS) at the U.S. Department of Energy's Argonne National Laboratoryprovides this nation's (in fact, this hemisphere's) brightest storage...

  16. Proposed particle-beam characterizations for the APS undulator test line

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H.; Borland, M.; Milton, S.

    1993-09-01

    A research and development effort is underway at the Advanced Photon Source (APS) to use an rf gun as a low-emittance electron source for injection into the 100- to 650-MeV linac subsystem and subsequently to an undulator test area. This configuration would combine the acceleration capability of the 200-MeV S-band electron linac and the in-line 450-MeV positron linac that normally provide positrons to the positron accumulator ring (PAR). A transport line that bypasses the PAR will bring the electrons to the undulator test area. Characterization techniques will be discussed for the electron beam with a normalized, rms emittance of <10 {pi} mm mrad (1{sigma}) at micropulse charges of up to 350 pC and micropulse durations of {approximately}5 ps (FWHM). Tests proposed include measurement of particle beam transport effects (at one-tenth the storage ring beam rigidity) caused by small undulator field errors as well as operations intended to produce coherent, short wavelength radiation (<200 nm).

  17. Detecting altered postural control after cerebral concussion in athletes with normal postural stability

    OpenAIRE

    Cavanaugh, J; Guskiewicz, K; Giuliani, C; Marshall, S; Mercer, V; Stergiou, N

    2005-01-01

    Objective: To determine if approximate entropy (ApEn), a regularity statistic from non-linear dynamics, could detect changes in postural control during quiet standing in athletes with normal postural stability after cerebral concussion.

  18. The research on AP1000 nuclear main pumps’ complete characteristics and the normalization method

    International Nuclear Information System (INIS)

    Zhu, Rongsheng; Liu, Yong; Wang, Xiuli; Fu, Qiang; Yang, Ailing; Long, Yun

    2017-01-01

    Highlights: • Complete characteristics of main pump are researched into. • The quadratic character of head and torque under some operatings. • The characteristics tend to be the same under certain conditions. • The normalization method gives proper estimations on external characteristics. • The normalization method can efficiently improve the security computing. - Abstract: The paper summarizes the complete characteristics of nuclear main pumps based on experimental results and makes a detailed study, and then draws a series of important conclusions: with regard to the overall flow area, the runaway operating and 0-revolving-speed operating of nuclear main pumps both have quadratic characteristics; with regard to the infinite flow, the braking operation and the 0-revolving-speed operation show consistent external characteristics. To remedy the shortcomings of the traditional complete-characteristic expression with regards to only describing limited flow sections at specific revolving speeds, the paper proposes a normalization method. As an important boundary condition of the security computing of unstable transient process of the primary reactor coolant pump and the nuclear island primary circuit and secondary circuit, the precision of complete-characteristic data and curve impacts the precision of security computing. A normalization curve obtained by applying the normalization method to process complete-characteristic data could correctly, completely and precisely express the complete characteristics of the primary reactor coolant pump under any rotational speed and full flow, and is capable of giving proper estimations on external characteristics of the flow outside the test range and even of the infinite flow. These advantages are of great significance for the improvement of security computing of transient processes of the primary reactor coolant pump and the circuit system.

  19. AP1000 - the new standard for nuclear power

    International Nuclear Information System (INIS)

    Lipman, Daniel S.

    2006-01-01

    Full text of publication follows: The AP1000 is the only Generation III+ reactor to receive Final Design Approval (FDA) from the Nuclear Regulatory Commission, and is expected to receive its Design Certification by the end of the year. Building on the proven features of current generation nuclear plants, the AP1000 combines experience with innovation into a design that surpasses current standards of safety and reliability. Use of passive safety features results in a simpler and more compact design that enhances safety, simplifies O and M requirements, and reduces capital and operating costs. At 1117 Mwe, the AP1000 is well suited for almost any grid system and will be fully competitive with combined-cycle gas and comparable fossil fuel plants. The AP1000 is ready to help launch a renaissance in new nuclear plant construction throughout the world. Maturity of Design: In excess of 1300 man-years and $400 million in development funding have been expended on the AP1000. It has undergone extensive, part scale testing at the system, sub-system and component level, in addition to a series of part scale integrated tests. The AP1000 is the most analyzed of the next generation reactors. Simplicity of Design/Economics: The AP1000 uses simplified and innovative passive safety systems to an unprecedented extent. Simplified passive safety systems provide reliable operation, reduced capital costs, and enhanced plant safety with large plant operating margins. The AP1000 features improved reliability through simplicity rather than addition of redundant safety trains. This simpler design is easier and less costly to operate and maintain than larger, more complex plants, while less equipment and smaller buildings translate into lower capital costs and shorter construction durations. After construction, economic benefit will be found in reduced operating and maintenance costs, largely due to reduced operating and maintenance staffing requirements. Construction aspects

  20. Maintenance of the APS of an electron beam accelerator

    International Nuclear Information System (INIS)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Kim, Sung Chan

    2008-12-01

    APS is a part of power supply system which provides the high voltage, high current to the anode of electron beam in the irradiation facility in KAERI. This APS had been used in turn-key base for 10 years, and frequently the Russian scientists had visited to repair this machine. In Summer the humid air had been supplied to dissipate the heat of APS. There is a big and high frequency noise around the transformer in the mutation room. So we stopped the irradiation works and analyzed and repaired the APS. The main course of the problem is the deterioration of IGBT and thyristors which are components of phase controller. We replaced this by new one and APS is now operating well

  1. The APS control system network

    International Nuclear Information System (INIS)

    Sidorowicz, K.V.; McDowell, W.P.

    1995-01-01

    The APS accelerator control system is a distributed system consisting of operator interfaces, a network, and computer-controlled interfaces to hardware. This implementation of a control system has come to be called the open-quotes Standard Model.close quotes The operator interface is a UNDC-based workstation with an X-windows graphical user interface. The workstation may be located at any point on the facility network and maintain full functionality. The function of the network is to provide a generalized communication path between the host computers, operator workstations, input/output crates, and other hardware that comprise the control system. The crate or input/output controller (IOC) provides direct control and input/output interfaces for each accelerator subsystem. The network is an integral part of all modem control systems and network performance will determine many characteristics of a control system. This paper will describe the overall APS network and examine the APS control system network in detail. Metrics are provided on the performance of the system under various conditions

  2. A hot-spare injector for the APS linac

    International Nuclear Information System (INIS)

    Lewellen, J. W.

    1999-01-01

    Last year a second-generation SSRL-type thermionic cathode rf gun was installed in the Advanced Photon Source (APS) linac. This gun (referred to as ''gun2'') has been successfully commissioned and now serves as the main injector for the APS linac, essentially replacing the Koontz-type DC gun. To help ensure injector availability, particularly with the advent of top-up mode operation at the APS, a second thermionic-cathode rf gun will be installed in the APS linac to act as a hot-spare beam source. The hot-spare installation includes several unique design features, including a deep-orbit Panofsky-style alpha magnet. Details of the hot-spare beamline design and projected performance are presented, along with some plans for future performance upgrades

  3. Functional design criteria 241-AP-102 Flexible Receiver System

    International Nuclear Information System (INIS)

    Roblyer, S.P.

    1995-01-01

    A mixer pump was installed in the 1.07 m (42-in.) riser of the central pump pit of tank 241-AP-102 to mitigate potential fluid separation particle sedimentation by mixing the tank's contents. The mixer pump performed this function until failure. Its removal is now necessary to meet possible tank content removal commitments or other corrective actions. The proposed removal procedure requires a flexible receiver that will provide a barrier to contamination during removal and transfer of the pump to the mixer pump storage container. This document describes the functional design criteria of the flexible receiver. These criteria include the functional and performance requirements of the flexible receiver as a barrier to contamination during normal conditions and contingencies and the instrumentation requirements

  4. Studies of microparticles in patients with the antiphospholipid syndrome (APS).

    Science.gov (United States)

    Vikerfors, A; Mobarrez, F; Bremme, K; Holmström, M; Ågren, A; Eelde, A; Bruzelius, M; Antovic, A; Wallén, H; Svenungsson, E

    2012-06-01

    To study circulating platelet, monocyte and endothelial microparticles (PMPs, MMPs and EMPs) in patients with antiphospholipid syndrome (APS) in comparison with healthy controls. Fifty-two patients with APS and 52 healthy controls were investigated. MPs were measured on a flow cytometer (Beckman Gallios) and defined as particles sized APS patients versus controls (p APS patients. We observed a high number of EMPs expressing TF in APS patients. The numbers of MMPs and total EMPs were also higher as compared with healthy controls but in contrast to previous reports, the number of PMPs did not differ between groups.

  5. Preliminary analyses of AP600 using RELAP5

    International Nuclear Information System (INIS)

    Modro, S.M.; Beelman, R.J.; Fisher, J.E.

    1991-01-01

    This paper presents results of preliminary analyses of the proposed Westinghouse Electric Corporation AP600 design. AP600 is a two loop, 600 MW (e) pressurized water reactor (PWR) arranged in a two hot leg, four cold leg nuclear steam supply system (NSSS) configuration. In contrast to the present generation of PWRs it is equipped with passive emergency core coolant (ECC) systems. Also, the containment and the safety systems of the AP600 interact with the reactor coolant system and each other in a more integral fashion than present day PWRs. The containment in this design is the ultimate heat sink for removal of decay heat to the environment. Idaho National Engineering Laboratory (INEL) has studied applicability of the RELAP5 code to AP600 safety analysis and has developed a model of the AP600 for the Nuclear Regulatory Commission. The model incorporates integral modeling of the containment, NSSS and passive safety systems. Best available preliminary design data were used. Nodalization sensitivity studies were conducted to gain experience in modeling of systems and conditions which are beyond the applicability of previously established RELAP5 modeling guidelines or experience. Exploratory analyses were then undertaken to investigate AP600 system response during postulated accident conditions. Four small break LOCA calculations and two large break LOCA calculations were conducted

  6. FRANX. Application for analysis and quantification of the APS fire; FRANK. Aplicacion para el analisis y cuantificacion de los APS de incendios

    Energy Technology Data Exchange (ETDEWEB)

    Snchez, A.; Osorio, F.; Ontoso, N.

    2014-07-01

    The FRANX application has been developed by EPRI within the Risk and Reliability User Group in order to facilitate the process of quantification and updating APS Fire (also covers floods and earthquakes). By applying fire scenarios are quantified in the central integrating the tasks performed during the APS fire. This paper describes the main features of the program to allow quantification of an APS Fire. (Author)

  7. Training and development of the Assistant Practitioners (APs) in radiography

    International Nuclear Information System (INIS)

    Stewart-Lord, Adéle

    2014-01-01

    A mixed methods study conducted over three phases (Phase I – scoping exercise, Phase II – questionnaire and Phase III – semi-structured interviews) aimed to explore the role and integration of the assistant practitioner (AP) practitioner in radiography from the AP perspective. Findings of the overall study are presented across a range of articles where this publication only presents the findings in relation to the training and education of APs from all three phases. Results showed the educational routes undertaken by APs in radiography during training. Training whilst working in the clinical department has highlighted a number of key issues relating to educational pathways and delivery methods. Findings showed that APs felt that more could be done to prepare the individual for clinical practice thereby increasing their confidence and facilitating role development. Results also identified a number of challenges in the training and education of APs in radiography. Clear routes of progression and career pathways are not available to APs in radiography. In conclusion the findings suggest the need for a review of existing educational programmes and future standardisation. The need exists to clarify the justifiable methods of training and differentiate between recognised educational qualifications to enable informed career development decisions by APs and their employers

  8. [Diverse histological lesions in a patient with antiphospholipid syndrome (APS)].

    Science.gov (United States)

    Salvatore, Ermanno; Luciani, Remo; Di Palma, Annamaria; Aversano, Arturo; Stellato, Davide; Liuzzi, Marco; Iele, Emilio; Martignetti, Vinicio; Spagnuolo, Enrico; Morrone, Luigi

    2011-01-01

    Antiphospholipid syndrome (APS) is a rare autoimmune disorder. It can be secondary to systemic lupus erythematosus (SLE) or occur in the absence of autoimmune disease. The hallmark of this so-called primary APS is the presence of circulating antiphospholipid antibodies. Renal involvement in primary APS is caused by thrombosis within the renal vasculature. Recently, nonthrombotic glomerulonephritic renal lesions have been described in primary APS as a new histological entity. We here report a patient with primary APS in whom both lesion types were present. A 58-year-old Caucasian man with no significant past medical history presented to our nephrology unit with diffuse edema. Urinalysis showed proteinuria exceeding 400 mg/dL. The autoantibody panel (p-ANCA, c- ANCA, anti-nucleus, anti-DS-DNA) was negative except for anticardiolipin antibodies, which tested positive in two different samples. The diagnostic workup included a kidney biopsy that revealed thrombotic lesions compatible with primary APS and a typical pattern of focal segmental glomerulosclerosis. The kidney is a major target in APS but the exact mechanism underlying the pathogenesis of APS nephropathy has been poorly recognized. The use of kidney biopsy is a fundamental diagnostic tool in this setting, with possible implications also from a prognostic and therapeutic viewpoint.

  9. Recessive loss-of-function mutations in AP4S1 cause mild fever-sensitive seizures, developmental delay and spastic paraplegia through loss of AP-4 complex assembly

    Science.gov (United States)

    Hardies, Katia; May, Patrick; Djémié, Tania; Tarta-Arsene, Oana; Deconinck, Tine; Craiu, Dana; Helbig, Ingo; Suls, Arvid; Balling, Rudy; Weckhuysen, Sarah; De Jonghe, Peter; Hirst, Jennifer; Afawi, Zaid; Barisic, Nina; Baulac, Stéphanie; Caglayan, Hande; Depienne, Christel; De Kovel, Carolien G.F.; Dimova, Petia; Guerrero-López, Rosa; Guerrini, Renzo; Hjalgrim, Helle; Hoffman-Zacharska, Dorota; Jahn, Johanna; Klein, Karl Martin; Koeleman, Bobby P.C.; Leguern, Eric; Lehesjoki, Anna-Elina; Lemke, Johannes; Lerche, Holger; Marini, Carla; Muhle, Hiltrud; Rosenow, Felix; Serratosa, Jose M.; Møller, Rikke S.; Stephani, Ulrich; Striano, Pasquale; Talvik, Tiina; Von Spiczak, Sarah; Weber, Yvonne; Zara, Federico

    2015-01-01

    We report two siblings with infantile onset seizures, severe developmental delay and spastic paraplegia, in whom whole-genome sequencing revealed compound heterozygous mutations in the AP4S1 gene, encoding the σ subunit of the adaptor protein complex 4 (AP-4). The effect of the predicted loss-of-function variants (p.Gln46Profs*9 and p.Arg97*) was further investigated in a patient's fibroblast cell line. We show that the premature stop mutations in AP4S1 result in a reduction of all AP-4 subunits and loss of AP-4 complex assembly. Recruitment of the AP-4 accessory protein tepsin, to the membrane was also abolished. In retrospect, the clinical phenotype in the family is consistent with previous reports of the AP-4 deficiency syndrome. Our study reports the second family with mutations in AP4S1 and describes the first two patients with loss of AP4S1 and seizures. We further discuss seizure phenotypes in reported patients, highlighting that seizures are part of the clinical manifestation of the AP-4 deficiency syndrome. We also hypothesize that endosomal trafficking is a common theme between heritable spastic paraplegia and some inherited epilepsies. PMID:25552650

  10. AP600 - an ALWR conceptual design

    International Nuclear Information System (INIS)

    Bruce, R.A.; Vijuk, R.P.

    1988-01-01

    The Electric Power Research Institute is spearheading an effort to develop utility requirements for the Advanced Light Water Reactor (ALWR) plants which will become the next generation nuclear power plants for the U.S. This EPRI ALWR Program involves utilities, the U.S. Department of Energy, the U.S. Nuclear Regulatory Commission, and various industry suppliers. The ALWR Program is aimed at ALWR plants which incorporate step improvements in safety, reliability, operability and power generation costs. As part of the ALWR efforts, a Westinghouse team is conducting conceptual design development of a PWR plant design called the AP600, reflecting advanced passive safety features and the chosen 600 MWe plant output. The AP600 conceptual design provides significant improvements while employing proven component technology. This paper describes the basic reactor and primary coolant system features, the passive safety system features, and plant arrangement/construction features of AP600

  11. AP1000R licensing and deployment in the United States

    International Nuclear Information System (INIS)

    Jordan, R. P.; Russ, P. A.; Filiak, P. P.; Castiglione, L. L.

    2012-01-01

    In recent years, both domestic and foreign utilities have turned to the standardized Westinghouse AP1000 plant design in satisfying their near - and long-term - sustainable energy needs. As direct support to these actions, licensing the AP1000 design has played a significant role by providing one of the fundamental bases in clearing regulatory hurdles leading to the start of new plant construction. Within the U.S. alone, Westinghouse AP1000 licensing activities have reached unprecedented milestones with the approvals of both AP1000 Design Certification and Southern Company's combined construction permit and operating license (COL) application directly supporting the construction of two new nuclear plants in Georgia. Further COL application approvals are immediately pending for an additional two AP1000 plants in South Carolina. And, across the U.S. nuclear industry spectrum, there are 10 other COL applications under regulatory review representing some 16 new plants at 10 sites. In total, these actions represent the first wave of new plant licensing under the regulatory approval process since 1978. Fundamental to the Nuclear Regulatory Commission's AP1000 Design Certification is the formal recognition of the AP1000 passive safety design through regulatory acceptance rulemaking. Through recognition and deployment of the AP1000 Design Certification, the utility licensee / operator of this reactor design are now offered an opportunity to use a simplified 'one-step' combined license process, thereby managing substantial back-end construction schedule risk from regulatory and intervention delays. Application of this regulatory philosophy represents both acceptance and encouragement of standardized reactor designs like the AP1000. With the recent AP1000 Design Certification and utility COL acceptances, the fundamental licensing processes of this philosophy have successfully proven the attainment of significant milestones with the next stage licensing actions directed

  12. The development of beam current monitors in the APS

    International Nuclear Information System (INIS)

    Wang, X.; Lenkszus, F.; Rotela, E.

    1995-01-01

    The Advanced Photon Source (APS) is a third-generation 7-GeV synchrotron radiation source. The precision measurement of beam current is a challenging task in high energy accelerators, such as the APS, with a wide range of beam parameters and complicated noise, radiation, and thermal environments. The beam pulses in the APS injector and storage ring have charge ranging from 50pC to 25nC with pulse durations varying from 30ps to 30ns. A total of nine non- intercepting beam current monitors have been installed in the APS facility (excluding those in the linac) for general current measurement. In addition, several independent current monitors with specially designed redundant interlock electronics are installed for personnel safety and machine protection. This paper documents the design and development of current monitors in the APS,. discusses the commissioning experience in the past year, and presents the results of recent operations

  13. AIRE variations in Addison's disease and autoimmune polyendocrine syndromes (APS)

    DEFF Research Database (Denmark)

    Bøe Wolff, A S; Oftedal, B; Johansson, S

    2008-01-01

    Autoimmune Addison's disease (AAD) is often associated with other components in autoimmune polyendocrine syndromes (APS). Whereas APS I is caused by mutations in the AIRE gene, the susceptibility genes for AAD and APS II are unclear. In the present study, we investigated whether polymorphisms...

  14. Final report for tank 241-AP-108, grab samples 8AP-96-1, 8AP-96-2 and 8AP-96-FB

    International Nuclear Information System (INIS)

    Esch, R.A.

    1996-01-01

    This document is the final report deliverable for the tank 241-AP-108 grab samples. The samples were subsampled and analyzed in accordance with the TSAP. Included in this report are the results for the Waste Compatibility analyses, with the exception of DSC and thermogravimetric analysis (TGA) results which were presented in the 45 Day report (Part 2 of this document). The raw data for all analyses, with the exception of DSC and TGA, are also included in this report

  15. AP1000 plant construction in China: Ansaldo Nucleare contribution

    International Nuclear Information System (INIS)

    Frogheri, Monica; Saiu, Gianfranco

    2009-01-01

    On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen site. The contract includes: the design of the steel containment vessel, preparation of construction and fabrication, specifications, design and supply of SCV mechanical penetrations, air locks and equipment hatches. Moreover, Ansaldo Nucleare is in charge of the final design of the AP1000 PRHR-HX and together with Mangiarotti Nuclear will supply the component for the Sanmen Unit 1 NPP. The paper presents an overview of the design and manufacturing activities performed by Ansaldo Nucleare and its partners for the AP1000 plant in China. (authors)

  16. 45-Day safety screening report for grab samples from Tank 241-AP-107

    International Nuclear Information System (INIS)

    Miller, G.L.

    1995-01-01

    Three samples; 107-AP-1C, 107-AP-2c and 107-AP-3C; were received at 222-S Laboratory for analysis of DSC, TGA and visual appearance. Four additional samples; 107-AP-1D, 107-AP-2D, 107-AP-3D and 107-AP-6; were received for visual appearance only. No results exceeded the safety screen notification criteria. This report compiles the analytical results. Tank 241-AP-107 is a double-shell tank which is not on any of the four Watch Lists

  17. RAD51AP2, a novel vertebrate- and meiotic-specific protein, sharesa conserved RAD51-interacting C-terminal domain with RAD51AP1/PIR51

    Energy Technology Data Exchange (ETDEWEB)

    Kovalenko, Oleg V.; Wiese, Claudia; Schild, David

    2006-07-25

    Many interacting proteins regulate and/or assist the activities of RAD51, a recombinase which plays a critical role in both DNA repair and meiotic recombination. Yeast two-hybrid screening of a human testis cDNA library revealed a new protein, RAD51AP2 (RAD51 Associated Protein 2), that interacts strongly with RAD51. A full-length cDNA clone predicts a novel vertebrate specific protein of 1159 residues, and the RAD51AP2 transcript was observed only in meiotic tissue (i.e. adult testis and fetal ovary), suggesting a meiotic-specific function for RAD51AP2. In HEK293 cells the interaction of RAD51 with an ectopically-expressed recombinant large fragment of RAD51AP2 requires the C-terminal 57 residues of RAD51AP2. This RAD51-binding region shows 81% homology to the C-terminus of RAD51AP1/PIR51, an otherwise totally unrelated RAD51-binding partner that is ubiquitously expressed. Analyses using truncations and point mutations in both RAD51AP1 and RAD51AP2 demonstrate that these proteins use the same structural motif for RAD51 binding. RAD54 shares some homology with this RAD51-binding motif, but this homologous region plays only an accessory role to the adjacent main RAD51-interacting region, which has been narrowed here to 40 amino acids. A novel protein, RAD51AP2, has been discovered that interacts with RAD51 through a C-terminal motif also present in RAD51AP1.

  18. Modalities of exploitation of the AP2 fuel fabrication plant at the FBFC facility of Romans-sur-Isere (INB98)

    International Nuclear Information System (INIS)

    2001-01-01

    This decision from the French authority of nuclear safety (ASN) aims at establishing a normal framework to the effluents management and waste storage activities that are carried out inside the 'south storage shed' of the AP2 fuel fabrication plant of the FBFC facility of Romans-sur-Isere (France). (J.S.)

  19. Packaging design criteria, transfer and disposal of 102-AP mixer pump

    International Nuclear Information System (INIS)

    Carlstrom, R.F.

    1994-01-01

    A mixer pump installed in storage tank 241-AP-102 (102-AP) has failed. This pump is referred to as the 102-AP mixer pump (APMP). The APMP will be removed from 102-AP 1 and a new pump will be installed. The main purpose of the Packaging Design Criteria (PDC) is to establish criteria necessary to design and fabricate a shipping container for the transfer and storage of the APMP from 102-AP. The PDC will be used as a guide to develop a Safety Evaluation for Packaging (SEP)

  20. Global coupling and decoupling of the APS storage ring

    International Nuclear Information System (INIS)

    Chae, Yong-Chul; Liu, Jianyang; Teng, L.C.

    1995-01-01

    This Paper describes a study of controlling the coupling between the horizontal and the vertical betatron oscillations in the APS storage ring. First, we investigate the strengthening of coupling using two families of skew quadrupoles. Using smooth approximation, we obtained the formulae to estimate the coupling ratio defined as the ratio of the vertical and horizontal emittances or, for a single particle, the ratio of the maximum values of the Courant Snyder invariants. Since we knew that the coupling is mostly enhanced by the 21st harmonic content of skew quadrupole distribution, we carried out the harmonic analysis in order to find the optimum arrangement of the skew quadrupoles. The numerical results from tracking a single particle are presented for the various configurations of skew quadrupoles. Second, we describe the global decoupling procedure to minimize the unwanted coupling effects. These are mainly due to the random roll errors of normal quadrupoles. It is shown that even with the rather large rms roll error of 2 mrad we can reduce the Coupling from 70 percent to 10 percent with a skew quadrupole strength which is one order of magnitude lower than the typical normal quadrupole strength

  1. A CoAP-Based Network Access Authentication Service for Low-Power Wide Area Networks: LO-CoAP-EAP

    Directory of Open Access Journals (Sweden)

    Dan Garcia-Carrillo

    2017-11-01

    Full Text Available The Internet-of-Things (IoT landscape is expanding with new radio technologies. In addition to the Low-Rate Wireless Personal Area Network (LR-WPAN, the recent set of technologies conforming the so-called Low-Power Wide Area Networks (LP-WAN offers long-range communications, allowing one to send small pieces of information at a reduced energy cost, which promotes the creation of new IoT applications and services. However, LP-WAN technologies pose new challenges since they have strong limitations in the available bandwidth. In general, a first step prior to a smart object being able to gain access to the network is the process of network access authentication. It involves authentication, authorization and key management operations. This process is of vital importance for operators to control network resources. However, proposals for managing network access authentication in LP-WAN are tailored to the specifics of each technology, which could introduce interoperability problems in the future. In this sense, little effort has been put so far into providing a wireless-independent solution for network access authentication in the area of LP-WAN. To fill this gap, we propose a service named Low-Overhead CoAP-EAP (LO-CoAP-EAP, which is based on previous work designed for LR-WPAN. LO-CoAP-EAP integrates the use of Authentication, Authorization and Accounting (AAA infrastructures and the Extensible Authentication Protocol (EAP protocol. For this integration, we use the Constrained Application Protocol (CoAP to design a network authentication service independent of the type of LP-WAN technology. LO-CoAP-EAP represents a trade-off between flexibility, wireless technology independence, scalability and performance in LP-WAN.

  2. A CoAP-Based Network Access Authentication Service for Low-Power Wide Area Networks: LO-CoAP-EAP.

    Science.gov (United States)

    Garcia-Carrillo, Dan; Marin-Lopez, Rafael; Kandasamy, Arunprabhu; Pelov, Alexander

    2017-11-17

    The Internet-of-Things (IoT) landscape is expanding with new radio technologies. In addition to the Low-Rate Wireless Personal Area Network (LR-WPAN), the recent set of technologies conforming the so-called Low-Power Wide Area Networks (LP-WAN) offers long-range communications, allowing one to send small pieces of information at a reduced energy cost, which promotes the creation of new IoT applications and services. However, LP-WAN technologies pose new challenges since they have strong limitations in the available bandwidth. In general, a first step prior to a smart object being able to gain access to the network is the process of network access authentication. It involves authentication, authorization and key management operations. This process is of vital importance for operators to control network resources. However, proposals for managing network access authentication in LP-WAN are tailored to the specifics of each technology, which could introduce interoperability problems in the future. In this sense, little effort has been put so far into providing a wireless-independent solution for network access authentication in the area of LP-WAN. To fill this gap, we propose a service named Low-Overhead CoAP-EAP (LO-CoAP-EAP), which is based on previous work designed for LR-WPAN. LO-CoAP-EAP integrates the use of Authentication, Authorization and Accounting (AAA) infrastructures and the Extensible Authentication Protocol (EAP) protocol. For this integration, we use the Constrained Application Protocol (CoAP) to design a network authentication service independent of the type of LP-WAN technology. LO-CoAP-EAP represents a trade-off between flexibility, wireless technology independence, scalability and performance in LP-WAN.

  3. GRIM-19 disrupts E6/E6AP complex to rescue p53 and induce apoptosis in cervical cancers.

    Directory of Open Access Journals (Sweden)

    Ying Zhou

    Full Text Available BACKGROUND: Our previous studies showed a down-regulation of GRIM-19 in primary human cervical cancers, and restoration of GRIM-19 induced tumor regression. The induction of tumor suppressor protein p53 ubiquitination and degradation by E6 oncoportein of high risk-HPV through forming a stable complex with E6AP is considered as a critical mechanism for cervical tumor development. The aims of this study were to determine the potential role of GRIM-19 in rescuing p53 protein and inducing cervical cancer cell apoptosis. METHODOLOGY/PRINCIPAL FINDINGS: The protein levels of GRIM-19 and p53 were detected in normal cervical tissues from 45 patients who underwent hysterectomy for reasons other than neoplasias of either the cervix or endometrium, and cervical cancer tissues from 60 patients with non-metastatic squamous epithelial carcinomas. Coimmunoprecipitation and GST pull-down assay were performed to examine the interaction of GRIM-19 with 18E6 and E6AP in vivo and in vitro respectively. The competition of 18E6 with E6AP in binding GRIM-19 by performing competition pull-down assays was designed to examine the disruption of E6/E6AP complex by GRIM-19. The augment of E6AP ubiquitination by GRIM-19 was detected in vivo and in vitro ubiquitination assay. The effects of GRIM-19-dependent p53 accumulation on cell proliferation, cell cycle, apoptosis were explored by MTT, flow cytometry and transmission electron microscopy respectively. The tumor suppression was detected by xenograft mouse model. CONCLUSION/SIGNIFICANCE: The levels of GRIM-19 and p53 were concurrently down regulated in cervical cancers. The restoration of GRIM-19 can induce ubiquitination and degradation of E6AP, and disrupt the E6/E6AP complex through the interaction of N-terminus of GRIM-19 with both E6 and E6AP, which protected p53 from degradation and promoted cell apoptosis. Tumor xenograft studies also revealed the suppression of p53 degradation in presence of GRIM-19. These data

  4. Enhancing AP1000 reactor accident management capabilities for long term accidents

    International Nuclear Information System (INIS)

    Jiang Pingting; Liu Mengying; Duan Chengjie; Liao Yehong

    2015-01-01

    Passive safety actions are considered as main measures under severe accident in AP1000 power plant. However, risk is still existed. According to PSA, several probable scenarios for AP1000 nuclear power plant are analyzed in this paper with MAAP the severe accident analysis code. According to the analysis results, several deficiencies of AP1000 severe accident management are found. The long term cooling and containment depressurization capability for AP1000 power plant appear to be most important factors under such accidents. Then, several temporary strategies for AP1000 power plant are suggested, including PCCWST temporary water supply strategy after 72h, temporary injection strategy for IRWST, hydrogen relief action in fuel building, which would improve the safety of AP1000 power plant. At last, assessments of effectiveness for these strategies are performed, and the results are compared with analysis without these strategies. The comparisons showed that correct actions of these strategies would effectively prevent the accident process of AP1000 power plant. (author)

  5. Essence and characteristics of the Westinghouse technology AP1000

    International Nuclear Information System (INIS)

    Llovet, Ricardo

    2014-01-01

    The AP1000 nuclear power plant can place the reactor in a Safe Shutdown Condition within the first 72 hours of a Station Blackout, without the use of AC power or operator action •With some operator action after 3 days, the AP1000 nuclear power plant continues to maintain reactor core cooling and Spent Fuel Pool cooling indefinitely •The AP1000 nuclear power plant has superior coping capabilities as well as significantly reduced risk for core damage

  6. Post-accident cooling capacity analysis of the AP1000 passive spent fuel pool cooling system

    International Nuclear Information System (INIS)

    Su Xia

    2013-01-01

    The passive design is used in AP1000 spent fuel pool cooling system. The decay heat of the spent fuel is removed by heating-boiling method, and makeup water is provided passively and continuously to ensure the safety of the spent fuel. Based on the analysis of the post-accident cooling capacity of the spent fuel cooling system, it is found that post-accident first 72-hour cooling under normal refueling condition and emergency full-core offload condition can be maintained by passive makeup from safety water source; 56 hours have to be waited under full core refueling condition to ensure the safety of the core and the spent fuel pool. Long-term cooling could be conducted through reserved safety interface. Makeup measure is available after accident and limited operation is needed. Makeup under control could maintain the spent fuel at sub-critical condition. Compared with traditional spent fuel pool cooling system design, the AP1000 design respond more effectively to LOCA accidents. (authors)

  7. Teaching Materials and Strategies for the AP Music Theory Exam

    Science.gov (United States)

    Lively, Michael T.

    2017-01-01

    Each year, many students take the Advanced Placement (AP) Music Theory Exam, and the majority of these students enroll in specialized AP music theory classes as part of the preparation process. For the teachers of these AP music theory classes, a number of challenges are presented by the difficulty and complexity of the exam subject material as…

  8. Induction of activator protein (AP)-1 and nuclear factor-kappaB by CD28 stimulation involves both phosphatidylinositol 3-kinase and acidic sphingomyelinase signals.

    Science.gov (United States)

    Edmead, C E; Patel, Y I; Wilson, A; Boulougouris, G; Hall, N D; Ward, S G; Sansom, D M

    1996-10-15

    A major obstacle in understanding the signaling events that follow CD28 receptor ligation arises from the fact that CD28 acts as a costimulus to TCR engagement, making it difficult to assess the relative contribution of CD28 signals as distinct from those of the TCR. To overcome this problem, we have exploited the observation that activated human T cell blasts can be stimulated via the CD28 surface molecule in the absence of antigenic challenge; thus, we have been able to observe the response of normal T cells to CD28 activation in isolation. Using this system, we observed that CD28 stimulation by B7-transfected CHO cells induced a proliferative response in T cells that was not accompanied by measurable IL-2 production. However, subsequent analysis of transcription factor generation revealed that B7 stimulation induced both activator protein-1 (AP-1) and nuclear factor-kappaB (NF-kappaB) complexes, but not NF-AT. In contrast, engagement of the TCR by class II MHC/superantigen, either with or without CD28 ligation, resulted in the induction of NF-AT, AP-1, and NF-kappaB as well as IL-2 production. Using selective inhibitors, we investigated the signaling pathways involved in the CD28-mediated induction of AP-1 and NF-kappaB. This revealed that NF-kappaB generation was sensitive to chloroquine, an inhibitor of acidic sphingomyelinase, but not to the phosphatidylinositol 3-kinase inhibitor, wortmannin. In contrast, AP-1 generation was inhibited by wortmannin and was also variably sensitive to chloroquine. These data suggest that in activated normal T cells, CD28-derived signals can stimulate proliferation at least in part via NF-kappaB and AP-1 generation, and that this response uses both acidic sphingomyelinase and phosphatidylinositol 3-kinase-linked pathways.

  9. NECAPs are negative regulators of the AP2 clathrin adaptor complex.

    Science.gov (United States)

    Beacham, Gwendolyn M; Partlow, Edward A; Lange, Jeffrey J; Hollopeter, Gunther

    2018-01-18

    Eukaryotic cells internalize transmembrane receptors via clathrin-mediated endocytosis, but it remains unclear how the machinery underpinning this process is regulated. We recently discovered that membrane-associated muniscin proteins such as FCHo and SGIP initiate endocytosis by converting the AP2 clathrin adaptor complex to an open, active conformation that is then phosphorylated (Hollopeter et al., 2014). Here we report that loss of ncap-1 , the sole C. elegans gene encoding an adaptiN Ear-binding Coat-Associated Protein (NECAP), bypasses the requirement for FCHO-1. Biochemical analyses reveal AP2 accumulates in an open, phosphorylated state in ncap-1 mutant worms, suggesting NECAPs promote the closed, inactive conformation of AP2. Consistent with this model, NECAPs preferentially bind open and phosphorylated forms of AP2 in vitro and localize with constitutively open AP2 mutants in vivo. NECAPs do not associate with phosphorylation-defective AP2 mutants, implying that phosphorylation precedes NECAP recruitment. We propose NECAPs function late in endocytosis to inactivate AP2. © 2018, Beacham et al.

  10. APS extends open access to all its journals

    CERN Multimedia

    Thomas, Kim

    2006-01-01

    "Physics research promoter and publisher the American Physical Society (APS) is to extend open access to all its journals. Th APS previously made its five print journals available through subscriptions, and its two e-journals (Physical Review Special Topics and Physics Educatoin Research) on an open access basis." (1/2 page)

  11. The Role of AP and the Composition Program.

    Science.gov (United States)

    Mahala, Daniel; Vivion, Michael

    1993-01-01

    Suggests that most programs have not based their acceptance of advanced placement credit on reasoned endorsement of the views of language, literature, and rhetoric that AP exams present. Criticizes the views implicit in the AP program and shows how they conflict with the goals of one particular college composition program. (RS)

  12. On the Realization of First-Order Current-Mode AP/HP Filter

    Directory of Open Access Journals (Sweden)

    W. Tangsrirat

    2013-12-01

    Full Text Available A compact circuit topology for the realization of the current-mode first-order allpass (AP and highpass (HP filters is described. The proposed circuit contains a minimum number of components, i.e., eight bipolar transistors and one grounded capacitor. The advantages of this circuit are the use of only grounded capacitor as a passive element, the electronic tunability of its parameters and its potential for low-voltage operation. Some simulation results are also reported, which demonstrate the effectiveness of the proposed circuit. Owing to the pole frequency of the filter circuit is normally dependent on temperature; a low-voltage translinear–based current source circuit for temperature compensation is also suggested.

  13. Learning through delivery, Westinghouse AP1000 plant construction

    International Nuclear Information System (INIS)

    Gorgemans, J.; Hinman, R.D.; Steuck, C.M.; Greco, P.L.

    2014-01-01

    The AP1000 plant, which is a 1100 MWe class pressurized water reactor with passive safety features, is designed around a conventional 2 loop, 2 steam generator primary system configuration with 2 hot legs, 4 reactor coolant pumps directly mounted in the steam generator lower head and 4 cold legs. A particular feature of AP1000 is its modular construction to minimize the time and cost of construction. Modular construction allows activities to be run in parallel, it allows more activities to be performed in a controlled factory instead of in the field, and it provides a better level of quality. The AP1000 plant design includes 106 structural modules and 52 mechanical modules. Structural modules include all penetrations for piping, cable trays, HVAC duct runs, and all reinforcement for pipe, equipment hangers, and supports. Structural modules are shipped in sub-modules to support transportation by rail or truck or barge. Mechanical modules contain equipment such as pumps, tanks, heat exchangers, air-handling units, and filters along with interconnecting pipes, valves, instruments, wiring and support services. Modular construction requires strong coordination between engineering, supply chain and construction. A total of 8 AP1000 units are currently under construction in China and in the United States. The lessons learned and best practices of each new AP1000 construction are systematically incorporated into the standard design. (A.C.)

  14. SEPTUM MAGNET DESIGN FOR THE APS-U

    Energy Technology Data Exchange (ETDEWEB)

    Abliz, M.; Jaski, M.; Xiao, A.; Wienands, U.; Cease, H.; Borland, M.; Decker, G.; Kerby, J.

    2017-06-25

    The Advanced Photon Source is in the process of upgrading its storage ring from a double-bend to a multi-bend lattice as part of the APS Upgrade Project (APS-U). A swap-out injection scheme is planned for the APS-U to keep a constant beam current and to enable a small dynamic aperture. A septum magnet with a minimum thickness of 2 mm and an injection field of 1.06 T has been designed, delivering the required total deflecting angle is 89 mrad with a ring energy of 6 GeV. The stored beam chamber has an 8 mm x 6 mm super-ellipsoidal aperture. The magnet is straight; however, it is tilted in yaw, roll, and pitch from the stored beam chamber to meet the on axis swap out injection requirements for the APS-U lattice. In order to minimize the leakage field inside the stored beam chamber, four different techniques were utilized in the design. As a result, the horizontal deflecting angle of the stored beam was held to only 5 µrad, and the integrated skew quadrupole inside the stored beam chamber was held to 0.09 T. The detailed techniques that were applied to the design, field multipoles, and resulting trajectories of the injected and stored beams are reported.

  15. Some ethylene biosynthesis and AP2/ERF genes reveal a specific pattern of expression during somatic embryogenesis in Hevea brasiliensis

    Directory of Open Access Journals (Sweden)

    Piyatrakul Piyanuch

    2012-12-01

    Full Text Available Abstract Background Ethylene production and signalling play an important role in somatic embryogenesis, especially for species that are recalcitrant in in vitro culture. The AP2/ERF superfamily has been identified and classified in Hevea brasiliensis. This superfamily includes the ERFs involved in response to ethylene. The relative transcript abundance of ethylene biosynthesis genes and of AP2/ERF genes was analysed during somatic embryogenesis for callus lines with different regeneration potential, in order to identify genes regulated during that process. Results The analysis of relative transcript abundance was carried out by real-time RT-PCR for 142 genes. The transcripts of ERFs from group I, VII and VIII were abundant at all stages of the somatic embryogenesis process. Forty genetic expression markers for callus regeneration capacity were identified. Fourteen markers were found for proliferating calli and 35 markers for calli at the end of the embryogenesis induction phase. Sixteen markers discriminated between normal and abnormal embryos and, lastly, there were 36 markers of conversion into plantlets. A phylogenetic analysis comparing the sequences of the AP2 domains of Hevea and Arabidopsis genes enabled us to predict the function of 13 expression marker genes. Conclusions This first characterization of the AP2/ERF superfamily in Hevea revealed dramatic regulation of the expression of AP2/ERF genes during the somatic embryogenesis process. The gene expression markers of proliferating callus capacity to regenerate plants by somatic embryogenesis should make it possible to predict callus lines suitable to be used for multiplication. Further functional characterization of these markers opens up prospects for discovering specific AP2/ERF functions in the Hevea species for which somatic embryogenesis is difficult.

  16. AP@home: a novel European approach to bring the artificial pancreas home.

    Science.gov (United States)

    Heinemann, Lutz; Benesch, Carsten; DeVries, J Hans

    2011-11-01

    The development of an artificial pancreas (AP) made huge strides from 2006 to 2008 and a large number of activities are going on in this area of research. Until now, most AP systems under development were tested only under highly controlled conditions. The aim of our project, funded by the European Union, is to develop an AP system to such a level that it can be studied under daily life conditions at the home of patients with diabetes (hence AP@home). Based on a subcutaneous-subcutaneous closed-loop strategy (i.e., glucose sensing and insulin infusion in the subcutaneous tissue), two different approaches will be taken to achieve this aim: a two-port AP system and a single-port AP system. The two-port AP system will use off-the-shelf-components for the glucose sensor and insulin pump in combination with closed-loop algorithms generated in Europe. As to the single-port AP system, two different innovative single-port systems will be developed; in this case, continuous glucose monitoring and insulin infusion will take place via a single catheter. The first clinical trials with the two-port AP system under controlled clinical conditions have started and good progress has been made in the development of the single-port AP systems. We believe that our consortium of 12 European partners, which builds on existing achievements and close cooperation between academic centers and industry, can contribute substantially to the development of an AP system that can be used by patients in daily life. © 2011 Diabetes Technology Society.

  17. AP1000: Meeting economic goals in a competitive world. Annex 7

    International Nuclear Information System (INIS)

    Davis, G.; Cummins, E.; Winters, J.

    2002-01-01

    In the U.S., conditions are becoming more favorable for considering the nuclear option again for new baseload generation. While oil and natural gas prices have risen, the cost of operating the existing fleet of nuclear plants has decreased. Furthermore, an advanced 1000 MWe nuclear plant that will be even more cost-competitive with fossil fuels and natural gas will be available by 2005. Westinghouse, in an effort to further improve on the AP600's cost competitiveness, has developed the AP1000, a two-loop, 1000 MWe, advanced pressurized water reactor (PWR) with passive safety features and extensive plant simplifications to enhance the construction, operation, and maintenance. Like the AP600, the AP1000 uses proven technology that builds on over 30 years of operating PWR experience. Westinghouse has completed design studies that demonstrate that it is feasible to increase the power output of the AP600 to at least 1000 MWe, maintaining its current design configuration and licensing basis. To maximize the cost savings, the AP1000 has been designed within the space constraints of the AP600, while retaining the credibility of proven components and substantial safety margins. The affect on the plant's overnight cost of the increased major components that is required to uprate the AP600 to 1000 MWe is small. This overall cost addition is on the order of 11 percent, while the overall power increase is almost 80 percent. This paper describes the changes made to uprate the AP600 and gives an overview of the plant design. (author)

  18. History of the APS Topical Group on Shock Compression of Condensed Matter

    International Nuclear Information System (INIS)

    Forbes, J W

    2001-01-01

    In order to provide broader scientific recognition and to advance the science of shock compressed condensed matter, a group of American Physical Society (APS) members worked within the Society to make this field an active part of the APS. Individual papers were presented at APS meetings starting in the 1940's and shock wave sessions were organized starting with the 1967 Pasadena meeting. Shock wave topical conferences began in 1979 in Pullman, WA. Signatures were obtained on a petition in 1984 from a balanced cross-section of the shock wave community to form an APS Topical Group (TG). The APS Council officially accepted the formation of the Shock Compression of Condensed Matter (SCCM) TG at its October 1984 meeting. This action firmly aligned the shock wave field with a major physical science organization. Most early topical conferences were sanctioned by the APS while those held after 1992 were official APS meetings. The topical group organizes a shock wave topical conference in odd numbered years while participating in shock wavehigh pressure sessions at APS general meetings in even numbered years

  19. Auricular Chondritis in a Postpartum Flare of SLE and APS

    Directory of Open Access Journals (Sweden)

    Elodie Ponce

    2014-10-01

    Full Text Available Introduction: Auricular chondritis has been occasionally described in patients with systemic lupus erythematosus (SLE and antiphospholipid syndrome (APS. Materials and methods: We report the case of a woman with a previous history of APS who presented with auricular chondritis with onset of SLE symptoms during the postpartum period. Conclusion: SLE and APS should be taken into consideration in the differential diagnosis of auricular chondritis.

  20. FRANX. Application for analysis and quantification of the APS fire

    International Nuclear Information System (INIS)

    Snchez, A.; Osorio, F.; Ontoso, N.

    2014-01-01

    The FRANX application has been developed by EPRI within the Risk and Reliability User Group in order to facilitate the process of quantification and updating APS Fire (also covers floods and earthquakes). By applying fire scenarios are quantified in the central integrating the tasks performed during the APS fire. This paper describes the main features of the program to allow quantification of an APS Fire. (Author)

  1. The Westinghouse Advanced Passive Pressurized Water Reactor, AP1000

    International Nuclear Information System (INIS)

    Schene, R.

    2009-01-01

    Featuring proven technology and innovative passive safety systems, the Westinghouse AP1000 pressurized water reactor can achieve competitive generation costs in the current electricity market without emitting harmful greenhouse gases and further harming the environment. Westinghouse Electric Company, the pioneer in nuclear energy once again sets a new industry standard with the AP1000. The AP1000 is a two-loop pressurized water reactor that uses simplified, innovative and effective approach to safety. With a gross power rating of 3415 megawatt thermal and a nominal net electrical output of 1117 megawatt electric, the AP1000 is ideal for new base load generation. The AP1000 is the safest and most economical nuclear power plant available in the worldwide commercial marketplace, and is the only Generation III+ reactor to receive a design certification from the U.S. Nuclear Regulatory Commission (NRC). Based on nearly 20 years of research and development, the AP1000 builds and improves upon the established technology of major components used in current Westinghouse designed plants. These components, including steam generators, digital instrumentation and controls, fuel, pressurizers, and reactor vessels, are currently in use around the world and have years of proven, reliable operating experience. Historically, Westinghouse plant designs and technology have forged the cutting edge technology of nuclear plant around the world. Today, nearly 50 percent of the world's 440 nuclear plants are based on Westinghouse technology. Westinghouse continues to be the nuclear industry's global leader. (author)

  2. Westinghouse plans global new builds for AP1000

    International Nuclear Information System (INIS)

    Mitev, Lubomir

    2014-01-01

    Interview with Danny Roderick, Westinghouse Electric Company, President and Chief Executive Officer since September 2012, about perspectives and future plans for AP1000 new build worldwide. Within three to four years there wille be 'shovels in the ground' for three new AP1000 reactors in the UK, as well as new units in China and Bulgaria. Four AP1000 reactors are under construction in the United States at Vogtle and VC Summer, and soon at Turkey Point. Additionally Danny Roderick spoke about the acquisition of NuGen, technology transfer, the influence of the Ukraine crises on the nuclear market in East Europe and the future need for more nuclear worldwide and in the UK and Bulgaria.

  3. Westinghouse plans global new builds for AP1000

    Energy Technology Data Exchange (ETDEWEB)

    Mitev, Lubomir [NucNet, Brussels (Belgium)

    2014-10-15

    Interview with Danny Roderick, Westinghouse Electric Company, President and Chief Executive Officer since September 2012, about perspectives and future plans for AP1000 new build worldwide. Within three to four years there wille be 'shovels in the ground' for three new AP1000 reactors in the UK, as well as new units in China and Bulgaria. Four AP1000 reactors are under construction in the United States at Vogtle and VC Summer, and soon at Turkey Point. Additionally Danny Roderick spoke about the acquisition of NuGen, technology transfer, the influence of the Ukraine crises on the nuclear market in East Europe and the future need for more nuclear worldwide and in the UK and Bulgaria.

  4. A new gap separation mechanism for APS insertion devices

    International Nuclear Information System (INIS)

    Trakhtenberg, E. M.; Tcheskidov, V.; Den Hartog, P. K.; Deriy, B.; Erdmann, M.; Makarov, O.; Moog, E. R.

    1999-01-01

    A new gap separation mechanism for use with the standard Advanced Photon Source (APS) 3.3-cm-period undulator magnetic structures has been designed and built and the first system has been installed in the APS storage ring. The system allows a minimum magnetic gap of 10 mm for use with the APS 8-mm insertion device vacuum chambers. The mechanism is a bolted steel frame structure with a simple 4-motor mechanical drive train. The control system uses servomotors with incremental rotary encoders and virtual absolute linear encoders

  5. AP600 design certification thermal hydraulics testing and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hochreiter, L.E.; Piplica, E.J.

    1995-09-01

    Westinghouse Electric Corporation, in conjunction with the Department of Energy and the Electric Power Research Institute, have been developing an advanced light water reactor design; the AP600. The AP600 is a 1940 Mwt, 600Mwe unit which is similar to a Westinghouse two-loop Pressurized Water Reactor. The accumulated knowledge on reactor design to reduce the capital costs, construction time, and the operational and maintenance cost of the unit once it begins to generate electrical power. The AP600 design goal is to maintain an overall cost advantage over fossil generated electrical power.

  6. The APS SASE FEL: modeling and code comparison

    International Nuclear Information System (INIS)

    Biedron, S. G.

    1999-01-01

    A self-amplified spontaneous emission (SASE) free-electron laser (FEL) is under construction at the Advanced Photon Source (APS). Five FEL simulation codes were used in the design phase: GENESIS, GINGER, MEDUSA, RON, and TDA3D. Initial comparisons between each of these independent formulations show good agreement for the parameters of the APS SASE FEL

  7. Kinetic properties of ATP sulfurylase and APS kinase from Thiobacillus denitrificans.

    Science.gov (United States)

    Gay, Sean C; Fribourgh, Jennifer L; Donohoue, Paul D; Segel, Irwin H; Fisher, Andrew J

    2009-09-01

    The Thiobacillus denitrificans genome contains two sequences corresponding to ATP sulfurylase (Tbd_0210 and Tbd_0874). Both genes were cloned and expressed protein characterized. The larger protein (Tbd_0210; 544 residues) possesses an N-terminal ATP sulfurylase domain and a C-terminal APS kinase domain and was therefore annotated as a bifunctional enzyme. But, the protein was not bifunctional because it lacked ATP sulfurylase activity. However, the enzyme did possess APS kinase activity and displayed substrate inhibition by APS. Truncated protein missing the N-terminal domain had APS kinase activity suggesting the function of the inactive sulfurylase domain is to promote the oligomerization of the APS kinase domains. The smaller gene product (Tbd_0874; 402 residues) possessed strong ATP sulfurylase activity with kinetic properties that appear to be kinetically optimized for the direction of APS utilization and ATP+sulfate production, which is consistent with an enzyme that functions physiologically to produce inorganic sulfate.

  8. Control of sulfate concentration by miR395-targeted APS genes in Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Qin Ai

    2016-04-01

    Full Text Available Sulfur nutrition is crucial for plant growth and development, as well as crop yield and quality. Inorganic sulfate in the soil is the major sulfur source for plants. After uptake, sulfate is activated by ATP sulfurylase, and then gets assimilated into sulfur-containing metabolites. However, the mechanism of regulation of sulfate levels by ATP sulfurylase is unclear. Here, we investigated the control of sulfate levels by miR395-mediated regulation of APS1/3/4. Sulfate was over-accumulated in the shoots of miR395 over-expression plants in which the expression of the APS1, APS3, and APS4 genes was suppressed. Accordingly, reduced expression of miR395 caused a decline of sulfate concentration. In agreement with these results, over-expression of the APS1, APS3, and APS4 genes led to the reduction of sulfate levels. Differential expression of these three APS genes in response to sulfate starvation implied that they have different functions. Further investigation revealed that the regulation of sulfate levels mediated by miR395 depends on the repression of its APS targets. Unlike the APS1, APS3, and APS4 genes, which encode plastid-localized ATP sulfurylases, the APS2 gene encodes a cytosolic version of ATP sulfurylase. Genetic analysis indicated that APS2 has no significant effect on sulfate levels. Our data suggest that miR395-targeted APS genes are key regulators of sulfate concentration in leaves.

  9. Functional description of APS beamline front ends

    International Nuclear Information System (INIS)

    Kuzay, T.

    1993-02-01

    Traditional synchrotron sources were designed to produce bending magnet radiation and have proven to be an essential scientific tool. Currently, a new generation of synchrotron sources is being built that will be able to accommodate a large number of insertion device (ID) and high quality bending magnet (BM) sources. One example is the 7-GeV Advanced Photon Source (APS) now under construction at Argonne National Laboratory. The research and development effort at the APS is designed to fully develop the potential of this new generation of synchrotron sources. Of the 40 straight sections in the APS storage ring, 34 will be available for IDs. The remaining six sections are reserved for the storage ring hardware and diagnostics. Although the ring incorporates 80 BMs, only 40 of them can be used to extract radiation. The accelerator hardware shadows five of these 40 bending magnets, so the maximum number of BM sources on the lattice is 35. Generally, a photon beamline consists of four functional sections. The first section is the ID or the BM, which provides the radiation source. The second section, which is immediately outside the storage ring but inside a concrete shielding tunnel, is the front end, which is designed to control, define, and/or confine the x-ray beam. In the case of the APS, the front ends are designed to confine the photon beam. The third section, just outside the concrete shielding tunnel and on the experimental floor, is the first optics enclosure, which contains optics to filter and monochromatize the photon beam. The fourth section of a beamline consists of beam transports, additional optics, and experiment stations to do the scientific investigations. This document describes only the front ends of the APS beamlines

  10. Thrombotic recurrences and bleeding events in APS vascular patients: a review from the literature and a comparison with the APS Piedmont Cohort.

    Science.gov (United States)

    Bazzan, M; Vaccarino, A; Stella, S; Bertero, M T; Carignola, R; Montaruli, B; Roccatello, D; Shoenfeld, Y

    2013-06-01

    In APS vascular patients, thrombotic recurrences are more frequent than in non-APS thrombotic patients. To better define this clinical setting, a systematic review of the literature after 1999 was performed: 8 cohort studies (including the recent APS Piedmont Cohort) and 6 intervention studies were selected and evaluated. Thrombotic recurrences, bleeding events, therapeutic strategies, antiphospholipid (aPL) profile, inherited and acquired risk factors (when present) were calculated and compared. Emerging risk factors for thrombotic recurrences include withdrawal of oral anticoagulant therapy (OAT), high intensity OAT (INR range 3-4), aPL profile (triple positivity, Miyakis types 1 and 2a profiles) and association with inherited or acquired pro-thrombotic risk factors. Moreover, there are evidences that high risk (mainly for aPL profile) APS vascular patients have a high recurrence rate in spite of correct OAT treatment. Clinical trials in this clinical setting are needed. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. AP1000{sup R} licensing and deployment in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, R. P.; Russ, P. A.; Filiak, P. P.; Castiglione, L. L. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    In recent years, both domestic and foreign utilities have turned to the standardized Westinghouse AP1000 plant design in satisfying their near - and long-term - sustainable energy needs. As direct support to these actions, licensing the AP1000 design has played a significant role by providing one of the fundamental bases in clearing regulatory hurdles leading to the start of new plant construction. Within the U.S. alone, Westinghouse AP1000 licensing activities have reached unprecedented milestones with the approvals of both AP1000 Design Certification and Southern Company's combined construction permit and operating license (COL) application directly supporting the construction of two new nuclear plants in Georgia. Further COL application approvals are immediately pending for an additional two AP1000 plants in South Carolina. And, across the U.S. nuclear industry spectrum, there are 10 other COL applications under regulatory review representing some 16 new plants at 10 sites. In total, these actions represent the first wave of new plant licensing under the regulatory approval process since 1978. Fundamental to the Nuclear Regulatory Commission's AP1000 Design Certification is the formal recognition of the AP1000 passive safety design through regulatory acceptance rulemaking. Through recognition and deployment of the AP1000 Design Certification, the utility licensee / operator of this reactor design are now offered an opportunity to use a simplified 'one-step' combined license process, thereby managing substantial back-end construction schedule risk from regulatory and intervention delays. Application of this regulatory philosophy represents both acceptance and encouragement of standardized reactor designs like the AP1000. With the recent AP1000 Design Certification and utility COL acceptances, the fundamental licensing processes of this philosophy have successfully proven the attainment of significant milestones with the next stage licensing

  12. Development and validation of the Affect in Play Scale-brief rating version (APS-BR).

    Science.gov (United States)

    Cordiano, Tori J Sacha; Russ, Sandra W; Short, Elizabeth J

    2008-01-01

    The Affect in Play Scale (APS; Russ, 1987, 2004) is one of few reliable, standardized measures of pretend play, yet the fact that it requires videotaping and extensive training to score compromises its clinical utility. In this study, we developed and validated a brief rating version (APS-BR) that does not require videotaping. Construct validity was established by comparing scores from the original APS and the APS-BR using an existing data set of videotaped play (n = 46). We examined associations between scores on the APS-BR and theoretically relevant measures of divergent thinking and emotional memories. Scores on the APS-BR related strongly to those on the APS, and the pattern of correlations for each scale and relevant criterion measures was similar in strength and direction, supporting the APS-BR as an alternate form of the APS. In addition, we completed a pilot study to examine the efficacy of using the APS-BR in its intended in vivo format (n = 28). Results from both studies suggest that the APS-BR is a promising brief measure of children's pretend play that can be substituted for the APS in clinical and research settings.

  13. Radioactive air emissions notice of construction for installation and operation of a waste retrieval system and tanks 241-AP-102 and 241-AP-104 project

    Energy Technology Data Exchange (ETDEWEB)

    DEXTER, M.L.

    1999-11-15

    This document serves as a notice of construction (NOC) pursuant to the requirements of Washington Administrative Code (WAC) 246 247-060, and as a request for approval to modify pursuant to 40 Code of Federal Regulations (CFR) 61 07 for the installation and operation of one waste retrieval system in the 24 1 AP-102 Tank and one waste retrieval system in the 241 AP 104 Tank Pursuant to 40 CFR 61 09 (a)( 1) this application is also intended to provide anticipated initial start up notification Its is requested that EPA approval of this application will also constitute EPA acceptance of the initial start up notification Project W 211 Initial Tank Retrieval Systems (ITRS) is scoped to install a waste retrieval system in the following double-shell tanks 241-AP 102-AP 104 AN 102, AN 103, AN-104, AN 105, AY 102 AZ 102 and SY-102 between now and the year 2011. Because of the extended installation schedules and unknowns about specific activities/designs at each tank, it was decided to submit NOCs as that information became available This NOC covers the installation and operation of a waste retrieval system in tanks 241 AP-102 and 241 AP 104 Generally this includes removal of existing equipment installation of new equipment and construction of new ancillary equipment and buildings Tanks 241 AP 102 and 241 AP 104 will provide waste feed for immobilization into a low activity waste (LAW) product (i.e. glass logs) The total effective dose equivalent (TEDE) to the offsite maximally exposed individual (MEI) from the construction activities is 0 045 millirem per year The unabated TEDE to the offsite ME1 from operation of the mixer pumps is 0 042 millirem per year.

  14. Radioactive air emissions notice of construction for installation and operation of a waste retrieval system and tanks 241-AP-102 and 241-AP-104 project

    International Nuclear Information System (INIS)

    DEXTER, M.L.

    1999-01-01

    This document serves as a notice of construction (NOC) pursuant to the requirements of Washington Administrative Code (WAC) 246 247-060, and as a request for approval to modify pursuant to 40 Code of Federal Regulations (CFR) 61 07 for the installation and operation of one waste retrieval system in the 24 1 AP-102 Tank and one waste retrieval system in the 241 AP 104 Tank Pursuant to 40 CFR 61 09 (a)( 1) this application is also intended to provide anticipated initial start up notification Its is requested that EPA approval of this application will also constitute EPA acceptance of the initial start up notification Project W 211 Initial Tank Retrieval Systems (ITRS) is scoped to install a waste retrieval system in the following double-shell tanks 241-AP 102-AP 104 AN 102, AN 103, AN-104, AN 105, AY 102 AZ 102 and SY-102 between now and the year 2011. Because of the extended installation schedules and unknowns about specific activities/designs at each tank, it was decided to submit NOCs as that information became available This NOC covers the installation and operation of a waste retrieval system in tanks 241 AP-102 and 241 AP 104 Generally this includes removal of existing equipment installation of new equipment and construction of new ancillary equipment and buildings Tanks 241 AP 102 and 241 AP 104 will provide waste feed for immobilization into a low activity waste (LAW) product (i.e. glass logs) The total effective dose equivalent (TEDE) to the offsite maximally exposed individual (MEI) from the construction activities is 0 045 millirem per year The unabated TEDE to the offsite ME1 from operation of the mixer pumps is 0 042 millirem per year

  15. The Dushak–Erekdag Survey of roAp Stars

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The search of roAp stars at Mt. Dushak–Erekdag Observatory was started in 1992 using the 0.8m Odessa telescope equipped with a two-star high-speed photometer. We have observed more than a dozen stars so far and discovered HD 99563 as roAp star while BD+8087 is suspected to have rapid ...

  16. AP-2α and AP-2β cooperatively orchestrate homeobox gene expression during branchial arch patterning.

    Science.gov (United States)

    Van Otterloo, Eric; Li, Hong; Jones, Kenneth L; Williams, Trevor

    2018-01-25

    The evolution of a hinged moveable jaw with variable morphology is considered a major factor behind the successful expansion of the vertebrates. DLX homeobox transcription factors are crucial for establishing the positional code that patterns the mandible, maxilla and intervening hinge domain, but how the genes encoding these proteins are regulated remains unclear. Herein, we demonstrate that the concerted action of the AP-2α and AP-2β transcription factors within the mouse neural crest is essential for jaw patterning. In the absence of these two proteins, the hinge domain is lost and there are alterations in the size and patterning of the jaws correlating with dysregulation of homeobox gene expression, with reduced levels of Emx, Msx and Dlx paralogs accompanied by an expansion of Six1 expression. Moreover, detailed analysis of morphological features and gene expression changes indicate significant overlap with various compound Dlx gene mutants. Together, these findings reveal that the AP-2 genes have a major function in mammalian neural crest development, influencing patterning of the craniofacial skeleton via the DLX code, an effect that has implications for vertebrate facial evolution, as well as for human craniofacial disorders. © 2018. Published by The Company of Biologists Ltd.

  17. Building an SDN enterprise WLAN based on virtual APs

    NARCIS (Netherlands)

    Sequeira, L.; Cruz, J.L. de la; Ruiz-Mas, J.; Saldana, J.; Fernandez-Navajas, J.; Almodovar, J.

    2017-01-01

    In this letter, the development and testing of an open enterprise Wi-Fi solution based on virtual access points (APs), managed by a central WLAN controller is presented. It allows seamless handovers between APs in different channels, maintaining the QoS of real-time services. The potential

  18. Heterologous expression in Tritrichomonas foetus of functional Trichomonas vaginalis AP65 adhesin

    Directory of Open Access Journals (Sweden)

    Alderete JF

    2005-03-01

    Full Text Available Abstract Background Trichomonosis, caused by Trichomonas vaginalis, is the number one, nonviral sexually transmitted infection that has adverse consequences for the health of women and children. The interaction of T. vaginalis with vaginal epithelial cells (VECs, a step preparatory to infection, is mediated in part by the prominent surface protein AP65. The bovine trichomonad, Tritrichomonas foetus, adheres poorly to human VECs. Thus, we established a transfection system for heterologous expression of the T. vaginalis AP65 in T. foetus, as an alternative approach to confirm adhesin function for this virulence factor. Results In this study, we show stable transfection and expression of the T. vaginalis ap65 gene in T. foetus from an episomal pBS-ap65-neo plasmid. Expression of the gene and protein was confirmed by RT-PCR and immunoblots, respectively. AP65 in transformed T. foetus bound to host cells. Specific mAbs revealed episomally-expressed AP65 targeted to the parasite surface and hydrogenosome organelles. Importantly, surface-expression of AP65 in T. foetus paralleled increased levels of adherence of transfected bovine trichomonads to human VECs. Conclusion The T. vaginalis AP65 adhesin was stably expressed in T. foetus, and the data obtained using this heterologous system strongly supports the role of AP65 as a prominent adhesin for T. vaginalis. In addition, the heterologous expression in T. foetus of a T. vaginalis gene offers an important, new approach for confirming and characterizing virulence factors.

  19. COBRA1 inhibits AP-1 transcriptional activity in transfected cells

    International Nuclear Information System (INIS)

    Zhong Hongjun; Zhu Jianhua; Zhang Hao; Ding Lihua; Sun Yan; Huang Cuifen; Ye Qinong

    2004-01-01

    Mutations in the breast cancer susceptibility gene (BRCA1) account for a significant proportion of hereditary breast and ovarian cancers. Cofactor of BRCA1 (COBRA1) was isolated as a BRCA1-interacting protein and exhibited a similar chromatin reorganizing activity to that of BRCA1. However, the biological role of COBRA1 remains largely unexplored. Here, we report that ectopic expression of COBRA1 inhibited activator protein 1 (AP-1) transcriptional activity in transfected cells in a dose-dependent manner, whereas reduction of endogenous COBRA1 with a small interfering RNA significantly enhanced AP-1-mediated transcriptional activation. COBRA1 physically interacted with the AP-1 family members, c-Jun and c-Fos, and the middle region of COBRA1 bound to c-Fos. Lack of c-Fos binding site in the COBRA1 completely abolished the COBRA1 inhibition of AP-1 trans-activation. These findings suggest that COBRA1 may directly modulate AP-1 pathway and, therefore, may play important roles in cell proliferation, differentiation, apoptosis, and oncogenesis

  20. Sonographic measurement of normal thyroid gland in the neonates

    International Nuclear Information System (INIS)

    Jeon, Gwun; Shin, Ji Hoon; Hong, Hyun Sook; Kim, Jung Hoon; Hwang, Jung Hwa; Goo, Dong Erk; Choi, Deuk Lin; Yang, Seung Boo

    2001-01-01

    The purpose of this study was to establish the sonographic measurement of normal thyroid gland in the neonates. Ultrasonographic evaluation of the thyroid gland was performed in the first week of life in 107 term neonates. The serum level of thyroid stimulating hormone was normal in all neonates. Their gestational age at birth was range from 37 to 41 weeks and birth weight was 3305 ± 457.74 g. Sonography was performed with 7.5 MHz linear array transducer (SA-8800 MT, Medison, Korea) within the first week of postnatal age. Maximal transverse (T), anteroposterior (AP), and longitudinal (L) dimensions of thyroid gland were measured. The volume of each lobe was estimate by using standard geometric formula; volume of a prolate ellipsoid = T X AP X L X π/6. The total volume of the thyroid gland was calculated as the sum of the each lobe. The correlations with total thyroid volume and weight, height, the body surface area, gestational age of the neonate were estimated by Pearson's coefficient and p volume on Bivariate correlation analysis. Total thyroid volume was 0.68 ± 0.23 cm 3 , left and right lobe volumes of thyroid gland were 0.32 ± 0.12 cm 3 and 0.36 ± 0.14 cm 3 , respectively. T, AP, and L dimension of right lobe were 0.69 ± 0.14 cm, 0.71 ± 0.13 cm, 1.37 ± 0.22 cm respectively. And those of left lobe were 0.70 ± 0.11 cm, 0.65 ± 0.13 cm, 1.31 ± 0.21 cm, respectively. The Pearson's coefficients for total thyroid volume with the weight, and body surface area of neonate were 0.385, 0.395 (p 3 and was significantly correlated with the weight and body surface area.

  1. Incorporating Ninth-Grade PSAT/NMSQT® Scores into AP Potential™ Predictions for AP® European History and AP World History. Statistical Report 2014-1

    Science.gov (United States)

    Zhang, Xiuyuan; Patel, Priyank; Ewing, Maureen

    2015-01-01

    Historically, AP Potential™ correlations and expectancy tables have been based on 10th-and 11th-grade PSAT/NMSQT® examinees and 11th-and 12th-grade AP® examinees for all subjects (Zhang, Patel, & Ewing,2014; Ewing, Camara, & Millsap, 2006; Camara & Millsap, 1998). However, a large number of students take AP European History and AP…

  2. AP@home: The Artificial Pancreas Is Now at Home

    NARCIS (Netherlands)

    Heinemann, Lutz; Benesch, Carsten; DeVries, J. Hans

    2016-01-01

    In the past years the development of an artificial pancreas (AP) has made great progress and many activities are ongoing in this area of research. The major step forward made in the last years was moving the evaluation of AP systems from highly controlled experimental conditions to daily life

  3. AP: A Critical Examination of the Advanced Placement Program

    Science.gov (United States)

    Sadler, Philip M.; Sonnert, Gerhard; Tai, Robert; Klopfenstein, Kirstin

    2016-01-01

    The Advanced Placement (AP) program was created to enhance the experience of gifted students as they transition from high school to college. "AP: A Critical Examination of the Advanced Placement Program," edited by Philip M. Sadler, Gerhard Sonnert, Robert Tai, and Kirstin Klopfenstein (2010, Harvard Education Press), questions the…

  4. Rate of transformation and normal range about cardiac size and cardiothoracic ratio according to patient position and age at chest radiography of Korean adult man

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Young Cheol [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Lim, Cheong Hwan; Jung, Hong Ryang [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Kim, Yun Min [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of); Hong, Dong Hee [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2017-06-15

    Purpose of this study is present the normal range of cardiac size and cardiothoracic ratio according to patient position(chest PA and AP) and age of Korean adult male on digital chest X - ray, And to propose a mutually compatible conversion rate. 1,024 males were eligible for this study, among 1,300 normal chest patients who underwent chest PA and low-dose CT examinations on the same day at the 'S' Hospital Health Examination Center in Seoul From January to December 2014. CS and CTR were measured by Danzer (1919). The mean difference between CS and CTR was statistically significant (p<0.01) in Chest PA (CS 135.48 mm, CTR 43.99%) and Chest AP image (CS 155.96 mm, CTR 51.75%). There was no statistically significant difference between left and right heart in chest PA and AP images(p>0.05). CS showed statistically significant difference between Chest PA (p>0. 05) and Chest AP (p<0.05). The thorax size and CTR were statistically significant (p<0.01) in both age and chest PA and AP. Result of this study, On Chest AP image CS was magnified 15%, CTR was magnified 17% compare with Chest PA image. CS and CTR were about 10% difference by changing posture at all ages.

  5. European utility requirements (EUR) volume 3 assessment for AP1000

    International Nuclear Information System (INIS)

    Saiu, G.; Demetri, K.J.

    2005-01-01

    The EUR (European Utility Requirements) Volume 3 is intended to report the Plant Description, the Compliance Assessment to EUR Volumes 1 and 2, and finally, the Specific Requirements for each specific Nuclear Power Plant Design considered by the EUR. Five subsets of EUR Volume 3, based on EUR Revision B, are already published; all of which are next generation plant designs being developed for Europe beyond 2000. They include : 1) EP1000 - Passive Pressurized Light Water Reactor (3-Loop, 1000 MWe) 2) EPR - Evolutionary Pressurized Light Water Reactor (1500 MWe) 3) BWR90/90+ - Evolutionary Boiling Water Reactor (1400 MWe) 4) ABWR - Evolutionary Boiling Water Reactor (1400 MWe) 5) SWR 1000 - Boiling Water Reactor With Passive Features (1000 MWe) In addition, the following subsets are currently being developed: 1) AP1000 - Passive Pressurized Light Water Reactor (2-Loop, 1117 MWe) 2) VVER AES 92 - Pressurized Water Reactor With Passive Features (1000 MWe) The purpose of this paper is to provide an overview of the program, which started in January 2004 with the EUR group to prepare an EUR Volume 3 Subset for the AP1000 nuclear plant design. The AP1000 EUR compliance assessment, to be performed against EUR Revision C requirements, is an important step for the evaluation of the AP1000 design for application in Europe. The AP1000 compliance assessment is making full use of AP1000 licensing documentation, EPP Phase 2 design activities and EP1000 EUR detailed compliance assessment. As of today, nearly all of the EUR Chapters have been discussed within the EUR Coordination Group. Based on the results of the compliance assessment, it can be stated that the AP1000 design shows a good level of compliance with the EUR Revision C requirements. Nevertheless, the compliance assessment has highlighted areas for where the AP1000 plant deviates from the EUR. The EPP design group has selected the most significant ones for performing detailed studies to quantify the degree of compliance

  6. MULTI-OBJECTIVE ONLINE OPTIMIZATION OF BEAM LIFETIME AT APS

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yipeng

    2017-06-25

    In this paper, online optimization of beam lifetime at the APS (Advanced Photon Source) storage ring is presented. A general genetic algorithm (GA) is developed and employed for some online optimizations in the APS storage ring. Sextupole magnets in 40 sectors of the APS storage ring are employed as variables for the online nonlinear beam dynamics optimization. The algorithm employs several optimization objectives and is designed to run with topup mode or beam current decay mode. Up to 50\\% improvement of beam lifetime is demonstrated, without affecting the transverse beam sizes and other relevant parameters. In some cases, the top-up injection efficiency is also improved.

  7. Shuttle APS propellant thermal conditioner study

    Science.gov (United States)

    Pearson, W. E.

    1971-01-01

    A study program was performed to allow selection of thermal conditioner assemblies for superheating O2 and H2 at supercritical pressures. The application was the auxiliary propulsion system (APS) for the space shuttle vehicle. The O2/H2 APS propellant feed system included propellant conditioners, of which the thermal conditioner assemblies were a part. Cryogens, pumped to pressures above critical, were directed to the thermal conditioner assembly included: (1) a gas generator assembly with ignition system and bipropellant valves, which burned superheated O2 and H2 at rich conditions; (2) a heat exchanger assembly for thermal conditioning of the cryogenic propellant; and (3) a dump nozzle for heat exchanger exhaust.

  8. The AP1000R nuclear power plant innovative features for extended station blackout mitigation

    International Nuclear Information System (INIS)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L.

    2012-01-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  9. AP Report to the Nation: A Closer Look at the Nation and Florida

    Science.gov (United States)

    Sawtell, Ellen A.; Gillie, Jacqueline M.; Smith, Patricia Z.

    2012-01-01

    In February 2012, the College Board published The 8th Annual AP Report to the Nation. This session provides a deeper dive into key information for the United States with an emphasis on Florida, and participants hear how one school in Florida utilizes AP Potential™ to help build their AP Program. Participants also learn about AP participation and…

  10. A Closer Examination of the Academic Benefits of AP

    Science.gov (United States)

    McKillip, Mary E. M.; Rawls, Anita

    2013-01-01

    The authors sought to better understand the relationship between students participating in the Advanced Placement (AP) program and subsequent performance on the Scholastic Aptitude Test (SAT). Focusing on students graduating from U.S. public high schools in 2010, the authors used propensity scores to match junior year AP examinees in 3 subjects to…

  11. APS power supply controls

    International Nuclear Information System (INIS)

    Saunders, C.W.; Despe, O.D.

    1994-01-01

    The purpose of this document is to provide comprehensive coverage of the APS power supply control design. This includes application software, embedded controller software, networks, and hardware. The basic components will be introduced first, followed by the requirements driving the overall design. Subsequent sections will address each component of the design one by one. Latter sections will address specific applications

  12. Study on modular construction management in AP1000 nuclear plant project

    International Nuclear Information System (INIS)

    Fang Xiaopeng; Shen Wenrong; Sun Kebin; Wei Zhong

    2010-01-01

    The construction of AP1000 Nuclear Power Plant (NPP) has commenced in China. The AP1000 NPP features a passive design concept and modular construction technology. Based on the management of the construction of current AP1000 NNP, this paper describes the effects on Nuclear Island (NI) construction project management resulting from modular construction technology, as well as new construction techniques and methods. This paper puts forward new requirements for construction schedule management of the nuclear island construction at different levels. The AP1000 NI construction logic features the parallel construction of civil and structural erection as the main approach, with the integrated schedule of module fabrication, assembly and installation as support. The structural modules of AP1000 project are prefabricated in shop, delivered to site as sub-modules and assembled to integrated structural module. The assembled module is transported to the construction site, hoisted and finally set in NI. This paper illustrates how to ensure the construction quality of structural modules by analyzing the interface process and key links in the quality control program, and introduces how to ensure the safety of heavy structural components during various construction phases by evaluating and analyzing the construction safety process. This paper also makes an analysis of the safe environment for the assembly and installation of Containment Vessel, the management of product protection and personnel safety inside the Containment Building during 'Open Top' construction, raises to implement effective protection for the numerous pre-set mechanical modules and equipments, as well as personnel safety protection programs and measures. The modular construction feature of AP1000 NPP design requires technique improvement and management innovation during the NI construction. This paper makes a study and research on the control management of schedule, quality and safety of AP1000 NPP NI

  13. Comportamento da eosinofilia após o tratamento das geohelmintoses

    Directory of Open Access Journals (Sweden)

    Marta Maria Bozóti

    1973-04-01

    Full Text Available A eosinofilia sanguínea após o tratamento anti-helmíntico específico se comportou numa amostragem de 57 crianças da seguinte forma: .Na ascaridíase isolada ou associada à trieuríase a hipereosinofilia parasitária ou descia uniformemente após o tratamento, ou houve primeiro uma exacerbação que durava até a terceira semana após a erradicação da, parasitose, descendo em seguida. Em ambos os casos houve normalização do hemograma em dois meses. Na associação ascaridíase/ancilostomíase também são possíveis dois tipos de comportamento da eosinofilia após tratamento eficaz: ou vai diminuindo a hipereosinofilia, logo em seguida à expulsão dos parasitos, ou há no primeiro mês um aumento da hipereosinofilia (geralmente mais acentuado na primeira semana que se segue ao tratamento, para diminuir após o fim do primeiro mês progressivamente até desaparecer. Na estrongiloidíase e na associação ascaridíase/estrongiloidíase há diminuição constante da hipereosinofilia logo após o tratamento e o hemograma se normaliza em cerca de dois meses. Na trieuríase, a hipereosinofilia, aliás já discreta, diminui pouco com o tratamento. Na ancilostomíase e na associação ancilostomíase/trieuríase a hipereosinofilia ou desce após o tratamento gradativo e lentamente, ou primeiro há uma exaltação temporária nas primeiras três semanas após a terapêutica, para diminuir em seguida. Na associação ancilostomíase/estrongiloidíase também se encontram esses dois tipos de comportamento da hipereosinofilia verminótica, mas a exacerbação da hipereosinofilia, que ocorre na metade dos casos, só dura duas semanas; a regressão eosinofílica ocorre dois meses após o tratamento. Nas tri e tetraeparasitoses a involução pós-terapêutica da hipereosinofilia é irregular e a normalização das taxas sanguíneas de eosinófilos é sempre arrastada, principalmente nas associações ascaridíase/estrongiloidíase/ancilostomíase e

  14. APS - Diagnostics and challenges for the future.

    Science.gov (United States)

    Pengo, V; Bison, E; Zoppellaro, G; Padayattil Jose, S; Denas, G; Hoxha, A; Ruffatti, A; Banzato, A

    2016-11-01

    Diagnosis of antiphospholipid syndrome (APS) is essentially based on the detection of circulating antiphospholipid (aPL) antibodies. Progress have been made on the standardization of tests exploring the presence of aPL as guidelines on coagulation and immunological tests were recently published in the literature. Clinical relevance of aPL profile has come from prospective cohort studies in populations with a homogeneous antibody profile supporting the view that triple positivity is a high risk pattern in patients and carriers. In addition to the classic ones, several other tests have been proposed for the diagnosis of APS. The detection of antibodies directed to domain 1 and 4/5 of β2-Glycoprotein I (β2GP1) were found to be particularly sound. Several issues remain to be addressed. We do not yet know what is the physiological function of β2GP1 and the pathophysiology of thrombosis and pregnancy loss in these patients. Moreover, treatment is poorly defined especially in the case of feared catastrophic APS. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Anti-phosphatidylserine/prothrombin antibodies: an additional diagnostic marker for APS?

    Science.gov (United States)

    Pregnolato, Francesca; Chighizola, Cecilia B; Encabo, Susan; Shums, Zakera; Norman, Gary L; Tripodi, Armando; Chantarangkul, Veena; Bertero, Tiziana; De Micheli, Valeria; Borghi, Maria Orietta; Meroni, Pier Luigi

    2013-07-01

    Among the diagnostic assays for anti-phospholipid syndrome (APS), lupus anticoagulant (LA) is the strongest predictor of thrombosis; however, it presents several limitations as interference with anticoagulant therapy and poor inter-laboratory agreement. Two-thirds of LA activity is apparently due to antibodies against prothrombin (PT), usually detectable by ELISA. Binding of PT to phosphatidylserine (PS) has been shown to enhance solid-phase anti-PT assay sensitivity. To determine the prevalence of antibodies against PS/PT (aPS/PT) in APS, we tested the semiquantitative QUANTA Lite(®) aPS/PT ELISA in a cohort of 80 APS patients. The prevalence of aPS/PT was 81.3%, rising to 87.6% when considering LA-positive subjects only. We observed a strong correlation between aPS/PT and LA (p = 0.006). To note, APS patients with thrombotic manifestations displayed significantly higher IgG aPS/PT titers compared to 20 aPL asymptomatic carriers (p = 0.012). To rule out a possible cross-reactivity of anti-β2 glycoprotein I antibodies (aβ2GPI) with PS/PT complex, we tested two monoclonal aβ2GPI antibodies and an affinity-purified (AP) polyclonal aβ2GPI IgG obtained from the serum of a patient reacting against both β2GPI and PS/PT. The two monoclonal antibodies did not show any reactivity against PS/PT complex, similarly the AP IgGs did not react toward PS/PT antigen while preserved their aβ2GPI activity. Our findings suggest that aPS/PT are a definite antibody population in APS. Moreover, the good correlation between aPS/PT ELISA and LA may support its use as a surrogate test for LA, particularly useful to overcome the technical limitations of the functional assay.

  16. Molecular Basis for Enhancement of the Meiotic DMCI Recombinase by RAD51AP1

    Energy Technology Data Exchange (ETDEWEB)

    Dray, Eloise; Dunlop, Myun Hwa; Kauppi, Liisa; San Filippo, Joseph San; Wiese, Claudia; Tsai, Miaw-Sheue; Begovic, Sead; Schild, David; Jasin, Maria; Keeney, Scott; Sung, Patrick

    2010-11-05

    Homologous recombination is needed for meiotic chromosome segregation, genome maintenance, and tumor suppression. RAD51AP1 (RAD51 Associated Protein 1) has been shown to interact with and enhance the recombinase activity of RAD51. Accordingly, genetic ablation of RAD51AP1 leads to enhanced sensitivity to and also chromosome aberrations upon DNA damage, demonstrating a role for RAD51AP1 in mitotic homologous recombination. Here we show physical association of RAD51AP1 with the meiosis-specific recombinase DMC1 and a stimulatory effect of RAD51AP1 on the DMC1-mediated D-loop reaction. Mechanistic studies have revealed that RAD51AP1 enhances the ability of the DMC1 presynaptic filament to capture the duplex DNA partner and to assemble the synaptic complex, in which the recombining DNA strands are homologously aligned. We also provide evidence that functional co-operation is dependent on complex formation between DMC1 and RAD51AP1, and that distinct epitopes in RAD51AP1 mediate interactions with RAD51 and DMC1. Finally, we show that RAD51AP1 is expressed in mouse testes, and that RAD51AP1 foci co-localize with a subset of DMC1 foci in spermatocytes. These results suggest that RAD51AP1 also serves an important role in meiotic homologous recombination.

  17. The antiphospholipid syndrome and its pathophysiological rol in the normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Quintana, Gerardo; Restrepo, Jose Felix; Iglesias, Antonio

    2008-01-01

    The antiphospholipid syndrome (APS) is an autoimmune disease with diverse manifestations, mainly thrombotic, in any part of the body, where the central system nervous is frequently involved and course with prominent clinical manifestations. In addition to presenting thrombus, the disease can present psychiatric alterations and a variety of non thrombotic neurological syndromes. Our report describes the clinical characteristics of presentation, laboratory finding and treatment in two cases: the first one of normal pressure hydrocephalus (NPH) associated to neurosyphilis and the other one and APS secondary to systemic lupus erythematosus (SLE). We emphasize the potential pathogenic role of the antiphospholipid antibodies in the generation of such a neurological entity. We commented and discussed the possible pathophysiological mechanisms in which the presence of such auto-antibody

  18. The dyad palindromic glutathione transferase P enhancer binds multiple factors including AP1.

    Science.gov (United States)

    Diccianni, M B; Imagawa, M; Muramatsu, M

    1992-10-11

    Glutathione Transferase P (GST-P) gene expression is dominantly regulated by an upstream enhancer (GPEI) consisting of a dyad of palindromically oriented imperfect TPA (12-O-tetradecanoyl-phorbol-13-acetate)-responsive elements (TRE). GPEI is active in AP1-lacking F9 cells as well in AP1-containing HeLa cells. Despite GPEI's similarity to a TRE, c-jun co-transfection has only a minimal effect on transactivation. Antisense c-jun and c-fos co-transfection experiments further demonstrate the lack of a role for AP1 in GPEI mediated trans-activation in F9 cells, although endogenously present AP1 can influence GPEI in HeLa cells. Co-transfection of delta fosB with c-jun, which forms an inactive c-Jun/delta FosB heterodimer that binds TRE sequences, inhibits GPEI-mediated transcription in AP1-lacking F9 cells as well as AP1-containing HeLa cells. These data suggest novel factor(s) other than AP1 are influencing GPEI. Binding studies reveal multiple nucleoproteins bind to GPEI. These factors are likely responsible for the high level of GPEI-mediated transcription observed in the absence of AP1 and during hepatocarcinogenesis.

  19. Discussion of QA grading for AP1000 NP plant

    International Nuclear Information System (INIS)

    Luo Shuiyun; Zhang Qingchuan

    2012-01-01

    The grading method of quality assurance for the following AP1000 project is presented based on the Westinghouse classification principle, referring to the classification method of the AP1000 self-reliance supporting project and considering the factors of classification, which can meet the requirements of domestic nuclear safety regulation and standard of the QA classification. (authors)

  20. Status of the Advanced Photon Source (APS) linear accelerator

    International Nuclear Information System (INIS)

    White, M.; Berg, W.; Fuja, R.; Grelick, A.; Mavrogenes, G.; Nassiri, A.; Russell, T.; Wesolowski, W.

    1993-01-01

    A 2856-MHz S-band, 450-MeV electron/positron linear accelerator is the first part of the injector for the Advanced Photon Source (APS) 7-GeV storage ring. Construction of the APS linac is currently nearing completion, and commissioning will begin in July 1993. The linac and its current status are discussed in this paper

  1. Application of MSHIM core control strategy for westinghouse AP1000 nuclear power plant

    International Nuclear Information System (INIS)

    Onoue, Masaaki; Kawanishi, Tomohiro; Carlson, William R.; Morita, Toshio

    2003-01-01

    Westinghouse has developed a new core control strategy, in which two independently moving Rod Cluster Control Assembly (RCCA) groups are utilized for core control; one group for reactivity/temperature control, the other for axial power distribution (Axial Offset) control. This control procedure eliminates the need for Chemical Shim adjustments during power maneuvers, such as load follow, and is designated MSHIM (Mechanical Shim). This core control strategy is utilized in the AP1000. In the AP1000, it is possible to perform MSHIM load follow maneuvers for up to 95% of cycle life without changing the soluble boron concentration in the moderator. This core control strategy has been evaluated, via computer simulations, to provide appropriate margins to core and fuel design limits during normal operation maneuvers (including load follow operations) and also during anticipated Condition II accident transients. The primary benefits of MSHIM as a control strategy are as follows; Power change operation can be totally automated due to the elimination of boron concentration adjustments. Full load follow capability is achievable for up to more than 95% of cycle life. Load follow operations performed solely by mechanical devices results in a significant reduction in the boron system requirements and a significant reduction in daily effluent to be processed. (author)

  2. Difference of reactor core nuclear instrument between AP1000 and CPR1000

    International Nuclear Information System (INIS)

    Zhang Shidong; Zhou Can; Deng Tian

    2014-01-01

    As a typical generation Ⅲ reactor technique, the AP1000 applies many advanced design concepts, simplifies the design, reduces equipment quantities, and thus enhances systematic reliability. The comparison of reactor core measurement instrument differences between AP1000 and CPR1000 from several aspects was involved in the paper. Through analysis and comparison of these differences, passive design concepts and characteristics of AP1000 are familiarized, and conveniences for staffs engaged in CPR1000 to learn and grasp AP1000 technique are provided. It is useful in reactor start up, operation and maintenance. (authors)

  3. Modeling Instruction in AP Physics C: Mechanics and Electricity and Magnetism

    Science.gov (United States)

    Belcher, Nathan Tillman

    This action research study used data from multiple assessments in Mechanics and Electricity and Magnetism to determine the viability of Modeling Instruction as a pedagogy for students in AP Physics C: Mechanics and Electricity and Magnetism. Modeling Instruction is a guided-inquiry approach to teaching science in which students progress through the Modeling Cycle to develop a fully-constructed model for a scientific concept. AP Physics C: Mechanics and Electricity and Magnetism are calculus-based physics courses, approximately equivalent to first-year calculus-based physics courses at the collegiate level. Using a one-group pretest-posttest design, students were assessed in Mechanics using the Force Concept Inventory, Mechanics Baseline Test, and 2015 AP Physics C: Mechanics Practice Exam. With the same design, students were assessed in Electricity and Magnetism on the Brief Electricity and Magnetism Assessment, Electricity and Magnetism Conceptual Assessment, and 2015 AP Physics C: Electricity and Magnetism Practice Exam. In a one-shot case study design, student scores were collected from the 2017 AP Physics C: Mechanics and Electricity and Magnetism Exams. Students performed moderately well on the assessments in Mechanics and Electricity and Magnetism, demonstrating that Modeling Instruction is a viable pedagogy in AP Physics C: Electricity and Magnetism.

  4. The Role of the Clathrin Adaptor AP-1: Polarized Sorting and Beyond

    Directory of Open Access Journals (Sweden)

    Fubito Nakatsu

    2014-11-01

    Full Text Available The selective transport of proteins or lipids by vesicular transport is a fundamental process supporting cellular physiology. The budding process involves cargo sorting and vesicle formation at the donor membrane and constitutes an important process in vesicular transport. This process is particularly important for the polarized sorting in epithelial cells, in which the cargo molecules need to be selectively sorted and transported to two distinct destinations, the apical or basolateral plasma membrane. Adaptor protein (AP-1, a member of the AP complex family, which includes the ubiquitously expressed AP-1A and the epithelium-specific AP-1B, regulates polarized sorting at the trans-Golgi network and/or at the recycling endosomes. A growing body of evidence, especially from studies using model organisms and animals, demonstrates that the AP-1-mediated polarized sorting supports the development and physiology of multi-cellular units as functional organs and tissues (e.g., cell fate determination, inflammation and gut immune homeostasis. Furthermore, a possible involvement of AP-1B in the pathogenesis of human diseases, such as Crohn’s disease and cancer, is now becoming evident. These data highlight the significant contribution of AP-1 complexes to the physiology of multicellular organisms, as master regulators of polarized sorting in epithelial cells.

  5. MDEP AP1000WG Design-Specific Common Position CP-AP1000WG-02. Common position addressing Fukushima Daiichi NPP accident-related issues

    International Nuclear Information System (INIS)

    2016-09-01

    A severe accident involving several units took place in Japan at Fukushima Daiichi nuclear power plant (NPP) in March 2011. The immediate cause of the accident was an earthquake followed by a tsunami coupled with inadequate provisions against the consequences of such events in the design. Opportunities to improve protection against a realistic design basis tsunami had not been taken. As a consequence of the tsunami, safety equipment and the related safety functions were lost at the plant, leading to core damage in three units and subsequently to large radioactive release. Several studies have already been performed to better understand the accident progression and detailed technical studies are still in progress in Japan and elsewhere. In the meantime, on-going studies on the behaviour of nuclear power plants in very severe situations, similar to Fukushima Daiichi, seek to identify potential vulnerabilities in plant design and operation; to suggest reasonably practicable upgrades; or to recommend enhanced regulatory requirements and guidance to address such situations. Likewise, agencies around the world that are responsible for regulating the design, construction and operation of AP1000 R plants are engaged in similar activities. The MDEP AP1000 R Working Group (AP1000 WG) members consist of members from Canada, China, the United Kingdom and the United States. Since the regulatory review of their AP1000 R applications have not been completed by all of these Countries yet, this paper identifies common preliminary approaches to address potential safety improvements for AP1000 R plants as related to lessons learned from the Fukushima Daiichi accident or Fukushima Daiichi-related issues. In seeking common position, regulators will provide input to this paper to reflect their safety conclusions regarding the AP1000 R design and how the design could be enhanced to address Fukushima Daiichi issues. The common preliminary approaches are organized into five sections

  6. Short time efficacy and safety of focused monopolar radiofrequency device for labial laxity improvement-noninvasive labia tissue tightening. A prospective cohort study.

    Science.gov (United States)

    Fistonić, Ivan; Sorta Bilajac Turina, Iva; Fistonić, Nikola; Marton, Ingrid

    2016-03-01

    To evaluate safety and efficacy of focused monopolar radio frequency (RF) device for non-invasive labia tissue tightening and improvement of labial laxity. This prospective cohort study participants were 17 female subjects aged between 27 and 56 years with lax skin at the labia area. All subjects received four consecutive treatments at 7-day intervals with RF device (Exilis Protege IntimaR, BTL Industries Inc., Boston, MA). The primary efficacy outcome measure was defined as one or more point improvement on 1-4 scale for vulva appearance determined by three blinded evaluators. Digital photographs were taken at the baseline and 1 month after the last treatment. Sexual gratification was assessed with Female Sexual Functioning Index (FSFI) and patient discomfort by Visual Analogue Scale (VAS). An average 2.9 (of maximum 4) points improvement rate in vulvar appearance was observed (P RF device for non-invasive labia tissue tightening. The treatment is effective and safe with high patient satisfaction. © 2016 Wiley Periodicals, Inc.

  7. New approach for treatment of prolonged postoperative pain: APS Out-Patient Clinic.

    Science.gov (United States)

    Tiippana, Elina; Hamunen, Katri; Heiskanen, Tarja; Nieminen, Teija; Kalso, Eija; Kontinen, Vesa K

    2016-07-01

    Persistent postoperative pain (PPP) is a significant clinical problem. Several patient-related risk factors for PPP have been identified, including a previous chronic pain problem, young age, female gender and psychological vulnerability. Intra- and postoperative risk factors include surgical complications such as infections, haematoma, nerve damage and repeated surgery. As the length of hospital stay has been shortened, some patients may be discharged despite ongoing pain and insufficient analgesic medication. The challenge is to identify patients at high risk of developing PPP and to create a targeted care pathway to ensure effective and safe pain treatment especially in the subacute postoperative phase at home. This observational study describes the first two years of the Acute Pain Service Out-Patient Clinic (APS-OPC) at the Helsinki University Hospital. Patient characteristics, known risk factors, and details of treatment of PPP for the first 200 patients referred to our APS-OPC were retrospectively collected from the medical records. The APS-OPC clinic functions in close collaboration with the Multidisciplinary Pain Clinic (MPC), and the number of patients in need of physiotherapist, psychologist or psychiatrist counselling was recorded, as well as the number of patients referred to the MPC for further PPP management. Patients were referred to the APS-OPC from different surgical specialities, the two most common being thoracic and orthopaedic surgery. Seventy per cent of the patients (139/200) presented symptoms indicating neuropathic postsurgical pain. The patients had, on average, five risk factors for PPP. The median time from surgery to the first contact to the APS-OPC was two months, and the median duration of follow-up was 2.8 months (0-16 months). The median number of contacts with APS-OPC was 3 (range 1-14). Every fourth patient needed only one contact to the APS-OPC. Nineteen per cent of the patients had an appointment with the physiotherapist and 20

  8. AP-102/104 Retrieval control system qualification test procedure

    International Nuclear Information System (INIS)

    RIECK, C.A.

    1999-01-01

    This Qualification Test Procedure documents the results of the qualification testing that was performed on the Project W-211, ''Initial Tank Retrieval Systems,'' retrieval control system (RCS) for tanks 241-AP-102 and 241-AP-104. The results confirm that the RCS has been programmed correctly and that the two related hardware enclosures have been assembled in accordance with the design documents

  9. The immunobiology and clinical features of type 1 autoimmune polyglandular syndrome (APS-1).

    Science.gov (United States)

    Guo, Can-Jie; Leung, Patrick S C; Zhang, Weici; Ma, Xiong; Gershwin, M Eric

    2018-01-01

    Autoimmune Polyglandular Syndrome type 1 (APS-1) is a subtype of the autoimmune polyendocrine syndrome characterized by the simultaneous or sequential dysfunction of multiple endocrine or non-endocrine glands. A clinical diagnosis of APS-1 is typically based on the presence of at least two of three following criteria: chronic mucocutaneous candidiasis, hypoparathyroidism and adrenal insufficiency. The first identified causative mutated gene for APS-1 is autoimmune regulator (AIRE) encoding a critical transcription factor, which is primarily expressed in the medullary thymic epithelial cells (mTECs) for generating central immune tolerance. A wide range of chronic, debilitating complications, with no obvious correlation with genetics, makes a diagnosis of APS-1 challenging early in the disease course. Managing APS-1 is difficult due to its complexity, especially the intricate relationships within manifestations and genetic mutations. The past decades have witnessed dramatic progress in elucidating the function of AIRE and conducting large-scale cohort studies in APS-1. However, no clear evidence-based guidelines have been established in APS-1. In this review, we provide a detailed critical overview of the study history, epidemiology, clinical features, and related mechanisms of autoimmunity in APS-1, as well as currently available therapies for this autoimmune disorder. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. AP600 level of automation: United States utility perspective

    International Nuclear Information System (INIS)

    Bekkerman, A.Y.

    1997-01-01

    Design of the AP600 advanced nuclear plant man-machine interface system (M-MIS) is guided by the applicable requirements from the Utility Requirements Document (URD). However, the URD has left certain aspects of the M-MIS to be determined by the designer working together with utilities sponsoring the work. This is particularly true in the case of the level of automation to be designed into the M-MIS. Based on experience from currently operating plants, utilities have specified the identity and roles of personnel in the control room, which has led to establishing a number of level of automation issues for the AP600. The key role of automated computerized procedures in the AP600 automation has been determined and resolved. 5 refs

  11. Results of the AP600 advanced plant probabilistic risk assessment

    International Nuclear Information System (INIS)

    Bueter, T.; Sancaktar, S.; Freeland, J.

    1997-01-01

    The AP600 Probabilistic Risk Assessment (PRA) includes detailed models of the plant systems, including the containment and containment systems that would be used to mitigate the consequences of a severe accident. The AP600 PRA includes a level 1 analysis (core damage frequency), and a level 2 analysis (environmental consequences), an assessment of the plant vulnerability to accidents caused by fire or floods, and a seismic margins analysis. Numerous sensitivities are included in the AP600 PRA including one that assumes no credit for non-safety plant systems. The core damage frequency for the AP600 of 1.7E-07/year is small compared with other PRAs performed in the nuclear industry. The AP600 large release frequency of 1.8E-08/year is also small and shows the ability of the containment systems to prevent a large release should a severe accident occur. Analyses of potential consequences to the environment from a severe accident show that a release would be small, and that containment still provides significant protection 24 hours after an assumed accident. Sensitivity analyses show that plant risk (as measured by core damage frequency and large release frequency) is not sensitive to the reliability of operator actions. 6 refs., 1 fig., 1 tab

  12. Sherwood/APS 2006 Conference. Final report

    International Nuclear Information System (INIS)

    Drake, James F.

    2009-01-01

    The International Sherwood Theory Meeting is a yearly meeting that focuses on the theory of magnetically confined fusion plasmas. There are many topics of common interest in fusion plasma systems and space and astrophysical plasmas. These common topics include such key topics as magnetic reconnection, the dynamo, turbulence and transport and particle heating and acceleration. One of the major participants of the April APS meeting is the APS Division of Astrophysics (DAP). The goal of having the Sherwood Meeting jointly with the April meeting was to promote discussion of topics of common interest in fusion and space and astrophysics. Scientists from the DAP, the Division of Plasma Physics (DPP), the Topical Group on Plasma Astrophysics (GPAP) and Sherwood worked together closely to produce a joint program that addressed areas of common interest. Four sessions of invited talks were sponsored jointly by the DAP, DPP and GPAP on laboratory experiments related to astrophysics. Plasma scientists working in theory and computation play a key role in connecting these laboratory experiments to the very disparate conditions found in fusion and astrophysical systems. Thus, the attendees of the Sherwood Theory meeting were critical to facilitating this effort at cross-disciplinary communication. Noteworthy were the selection of two of the prestigious plenary talks at the joint meeting on plasma topics - one related to the gyrokinetic modeling of turbulence and the other related to the structure of collisionless shocks. It is rare to see even a single plenary talk on plasma physics at the APS April Meeting. There were additional costs associated with hosting a joint meeting. The Office of Fusion Energy Sciences contributed $3000 in partial support of this meeting. This funding covered part of the costs of the poster boards and A. V. equipment that was used in the presentation of nearly 200 scientific papers related to magnetically confined fusion plasmas. The APS waived its

  13. Impacto do padrão geométrico ventricular na remodelação cardíaca após o infarto do miocárdio

    Directory of Open Access Journals (Sweden)

    Elaine Farah

    2013-06-01

    Full Text Available FUNDAMENTO: A relevância do padrão de geometria após o infarto do miocárdio não é conhecida. OBJETIVOS: Analisar a presença de diferentes padrões de geometria ventricular esquerda (VE e seu impacto como preditor de remodelação em pacientes com infarto do miocárdio. MÉTODOS: Pacientes com infarto agudo anterior (n = 80 foram divididos de acordo com o padrão de geometria: normal (índice de massa [IMVE] normal e espessura relativa da parede [ERP] normal, remodelação concêntrica (IMVE normal e ERP aumentada, hipertrofia concêntrica (IMVE e ERP aumentadas e hipertrofia excêntrica (IMVE aumentado e ERP normal. Após seis meses, foi repetido o ecocardiograma. RESULTADOS: Quatro pacientes foram a óbito. Dos sobreviventes, 41 apresentaram remodelação (R+, enquanto 39 não remodelaram (R-. Considerando-se o padrão geométrico, houve a seguinte distribuição: 24 pacientes com padrão normal, 13 com remodelação concêntrica, 29 com hipertrofia concêntrica e 14 com hipertrofia excêntrica. Os pacientes que remodelaram apresentaram maiores tamanhos de infarto analisados pelo pico da CPK (R+ = 4.610 (1.688 - 7.970, R- = 1.442 (775 - 4.247, p < 0,001 e da CK-MB (R+ = 441 (246 - 666, R- = 183 (101 - 465, p < 0,001, tendência a maior prevalência de remodelação concêntrica (R+ = 10, R- = 3, p = 0,08 e menor prevalência de hipertrofia excêntrica (R+ = 2, R- = 12, p = 0,006. Na análise de regressão multivariada, o tamanho do infarto foi preditor (OR = 1,01; p = 0,020 e a hipertrofia excêntrica foi fator protetor (OR = 0,189; p = 0,046 de remodelação ventricular após a oclusão coronariana. CONCLUSÃO: O padrão de geometria ventricular pode ter impacto no processo de remodelação em pacientes com infarto do miocárdio.

  14. The AP1000{sup R} nuclear power plant innovative features for extended station blackout mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  15. Obstetric and vascular APS: same autoantibodies but different diseases?

    Science.gov (United States)

    Meroni, P L; Raschi, E; Grossi, C; Pregnolato, F; Trespidi, L; Acaia, B; Borghi, M O

    2012-06-01

    Beta2 glycoprotein I (β2GPI)-dependent antiphospholipid antibodies (aPLs) are the main pathogenic autoantibody population and at the same time the laboratory diagnostic tool for the antiphospholipid syndrome (APS). These antibodies are responsible for both the vascular and the obstetric manifestations of the syndrome but the pathogenic mechanisms behind these manifestations are not the same. For example, thrombotic events do not appear to play a major role in APS miscarriages and a direct reactivity of β2GPI-dependent aPLs on decidual and trophoblast cells was reported. A local expression of β2GPI on these tissues was reported both in physiological conditions and in APS women, thus explaining the local tropism of the autoantibodies. The two hit hypothesis was suggested to explain why the vascular manifestations of APS may occur only occasionally in spite of the persistent presence of aPLs. This is not apparently the case for the obstetric variant of the syndrome, making the difference even more striking. A different pathogenesis may also provide the rationale for the well-known fact that the vascular and the obstetric manifestations may occur independently although in a minority of cases.

  16. Functional interaction between the glucocorticoid receptor and GANP/MCM3AP

    International Nuclear Information System (INIS)

    Osman, Waffa; Laine, Sanna; Zilliacus, Johanna

    2006-01-01

    Glucocorticoids are widely used to treat inflammatory diseases but have a number of side effects that partly are connected to inhibition of cell proliferation. Glucocorticoids mediated their action by binding to the glucocorticoid receptor. In the present study, we have identified by two-hybrid screens the germinal center-associated protein (GANP) and MCM3-associated protein (MCM3AP), a splicing variant of GANP, as glucocorticoid receptor interacting proteins. GANP and MCM3AP can bind to the MCM3 protein involved in initiation of DNA replication. Glutathione-S-transferase-pull-down and co-immunoprecipitation assays showed that the C-terminal domain of GANP, encompassing MCM3AP, interacts with the ligand-binding domain of the glucocorticoid receptor. Characterization of the intracellular localization of GANP revealed that GANP is shuttling between the nucleus and the cytoplasm. Furthermore, we show that glucocorticoids are unable to inhibit DNA replication in HeLa cells overexpressing MCM3AP suggesting a role for both glucocorticoid receptor and GANP/MCM3AP in regulating cell proliferation

  17. X-ray optics simulation and beamline design for the APS upgrade

    Science.gov (United States)

    Shi, Xianbo; Reininger, Ruben; Harder, Ross; Haeffner, Dean

    2017-08-01

    The upgrade of the Advanced Photon Source (APS) to a Multi-Bend Achromat (MBA) will increase the brightness of the APS by between two and three orders of magnitude. The APS upgrade (APS-U) project includes a list of feature beamlines that will take full advantage of the new machine. Many of the existing beamlines will be also upgraded to profit from this significant machine enhancement. Optics simulations are essential in the design and optimization of these new and existing beamlines. In this contribution, the simulation tools used and developed at APS, ranging from analytical to numerical methods, are summarized. Three general optical layouts are compared in terms of their coherence control and focusing capabilities. The concept of zoom optics, where two sets of focusing elements (e.g., CRLs and KB mirrors) are used to provide variable beam sizes at a fixed focal plane, is optimized analytically. The effects of figure errors on the vertical spot size and on the local coherence along the vertical direction of the optimized design are investigated.

  18. Aerosol-delivered programmed cell death 4 enhanced apoptosis, controlled cell cycle and suppressed AP-1 activity in the lungs of AP-1 luciferase reporter mice.

    Science.gov (United States)

    Hwang, S-K; Jin, H; Kwon, J T; Chang, S-H; Kim, T H; Cho, C-S; Lee, K H; Young, M R; Colburn, N H; Beck, G R; Yang, H-S; Cho, M-H

    2007-09-01

    The long-term survival of lung cancer patients treated with conventional therapies remains poor and therefore the need for novel approaches remains high. This has led to the re-emergence of aerosol delivery as a therapeutic intervention. In this study, glucosylated polyethylenimine (GPEI) was used as carrier to investigate programmed cell death 4 (PDCD4) and PDCD4 mutant (D418A), an eIF4A-binding mutant, on PDCD4-related signaling and activator protein-1 (AP-1) activity in the lungs of AP-1 luciferase reporter mice. After confirming the efficiency of GPEI as a carrier in lungs, the effects of aerosol-delivered PDCD4 were investigated in AP-1 luciferase reporter mice. Aerosol delivery of GPEI/PDCD4 through a nose-only inhalation facilitated the apoptosis of lungs whereas aerosol PDCD4 mutant did not. Also, such aerosol delivery regulated proteins relevant to cell-cycle control and suppressed AP-1 activity. Results obtained by western blot analysis, immunohistochemistry, luciferase assay and deoxynucleotidyl-transferase-mediated nick end labeling study suggest that combined actions such as facilitating apoptosis, controlling cell cycle and suppression of AP-1 activity by PDCD4 may provide useful tool for designing lung tumor prevention and treatment by which PDCD4 functions as a transformation suppressor in the future.

  19. Finite element modeling of AP1000 nuclear island

    International Nuclear Information System (INIS)

    Tinic, S.; Orr, R.

    2003-01-01

    The AP1000 is a standard design developed by Westinghouse and its partners for an advanced nuclear power plant utilizing passive safety features. It is based on the certified design of the AP600 and has been uprated to 1000 MWe. The plant has five principal building structures; the nuclear island, the turbine building; the annex building; the diesel generator building and the radwaste building. The nuclear island consists of the containment building (the steel containment vessel and the containment internal structures), the shield building, and the auxiliary building. These structures are founded on a common basemat and are collectively known as the nuclear island. This paper describes use of the general purpose finite element program ANSYS [2] in structural analyses and qualification of the AP1000 nuclear island buildings. It describes the modeling of the shield building and the auxiliary building and the series of analyses and the flow of information from the global analyses to the detailed analyses and building qualification. (author)

  20. APS-U LATTICE DESIGN FOR OFF-AXIS ACCUMULATION

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yipeng; Borland, M.; Lindberg, R.; Sajaev, V.

    2017-06-25

    A 67-pm hybrid-seven-bend achromat (H7BA) lattice is being proposed for a future Advanced Photon Source (APS) multi-bend-achromat (MBA) upgrade project. This lattice design pushes for smaller emittance and requires use of a swap-out (on-axis) injection scheme due to limited dynamic acceptance. Alternate lattice design work has also been performed for the APS upgrade to achieve better beam dynamics performance than the nominal APS MBA lattice, in order to allow off-axis accumulation. Two such alternate H7BA lattice designs, which target a still-low emittance of 90 pm, are discussed in detail in this paper. Although the single-particle-dynamics performance is good, simulations of collective effects indicate that surprising difficulty would be expected accumulating high single-bunch charge in this lattice. The brightness of the 90-pm lattice is also a factor of two lower than the 67-pm H7BA lattice.

  1. Caracterização físico-química, reológica, morfológica e térmica dos amidos de milho normal, ceroso e com alto teor de amilose Physicochemical, rheological, morphological, and thermal characterization of normal, waxy, and high amylose corn starches

    Directory of Open Access Journals (Sweden)

    Fernanda Hart Weber

    2009-12-01

    Full Text Available O objetivo do presente estudo foi avaliar os amidos de milho normal, ceroso e com alto teor de amilose, fabricados pela National Starch, por meio da determinação das suas características físico-químicas, morfológicas, térmicas e reológicas. O amido de milho com alto teor de amilose (AM apresentou teor de amilose igual a 71%, sendo que os valores obtidos para o amido de milho normal (M e o amido de milho ceroso (AP foram de 27,8 e 1,8%, respectivamente. Traços de proteína e lipídios foram encontrados nas amostras. O amido de milho ceroso apresentou maior viscosidade máxima e uma menor tendência à retrogradação, se comparado ao amido de milho normal. O amido AP apresentou menor entalpia de gelatinização, como pode ser observado nas análises de calorimetria exploratória diferencial (DSC, na qual a temperatura de gelatinização foi de 75 °C e o ΔH de 3,34 J.g-1, e também na análise de RVA (Rapid Visco Analyser, em que a temperatura de pasta foi de 71 °C. Apresentando, dessa forma, valores inferiores aos verificados para os outros amidos. O valor do ΔH de retrogradação do amido AP, mostrou-se 25,8% inferior ao ΔH do amido M. O amido AM apresentou o valor de 26,38 J.g-1, demonstrando o maior envolvimento da molécula de amilose no processo de retrogradação. Isso também foi evidenciado pela medida da força dos géis: o gel de AM apresentou força 99,18% superior, retrogradando mais que os outros amidos. As análises de difração de raio X mostraram que os amidos de milho normal e ceroso apresentaram um padrão de difração do tipo A e o amido de milho com alto teor de amilose apresentou padrão do tipo B.The objective of this work was to evaluate normal, waxy, and high amylose corn starches from National Starch, through the determination of the physicochemical, morphological, thermal, and rheological properties. The high amylose corn starch (AM presented amylose content of 71%, and the value of this component for the

  2. Tank characterization report for double-shell tank 241-AP-105

    International Nuclear Information System (INIS)

    DeLorenzo, D.S.; Simpson, B.C.

    1994-01-01

    Double-Shell Tank 241-AP-105 is a radioactive waste tank most recently sampled in March of 1993. Sampling and characterization of the waste in Tank 241-AP-105 contributes toward the fulfillment of Milestone M-44-05 of the Hanford Federal Facility Agreement and Consent Order (Ecology, EPA, and DOE, 1993). Characterization is also needed tot evaluate the waste's fitness for safe processing through an evaporator as part of an overall waste volume reduction program. Tank 241-AP-105, located in the 200 East Area AP Tank Farm, was constructed and went into service in 1986 as a dilute waste receiver tank; Tank 241AP-1 05 was considered as a candidate tank for the Grout Treatment Facility. With the cancellation of the Grout Program, the final disposal of the waste in will be as high- and low-level glass fractions. The tank has an operational capacity of 1,140,000 gallons, and currently contains 821,000 gallons of double-shell slurry feed. The waste is heterogeneous, although distinct layers do not exist. Waste has been removed periodically for processing and concentration through the 242-A Evaporator. The tank is not classified as a Watch List tank and is considered to be sound. There are no Unreviewed Safety Questions associated with Tank 241-AP-105 at this time. The waste in Tank 241-AP-105 exists as an aqueous solution of metallic salts and radionuclides, with limited amounts of organic complexants. The most prevalent soluble analytes include aluminum, potassium, sodium, hydroxide, carbonate, nitrate, and nitrite. The calculated pH is greater than the Resource Conservation and Recovery Act established limit of 12.5 for corrosivity. In addition, cadmium, chromium, and lead concentrations were found at levels greater than their regulatory thresholds. The major radionuclide constituent is 137 Cs, while the few organic complexants present include glycolate and oxalate. Approximately 60% of the waste by weight is water

  3. The interaction between the adaptor protein APS and Enigma is involved in actin organisation

    DEFF Research Database (Denmark)

    Barres, Romain; Gonzalez, Teresa; Le Marchand-Brustel, Yannick

    2005-01-01

    that was previously shown to be associated with the actin cytoskeleton. In HEK 293 cells, Enigma interacted specifically with APS, but not with the APS-related protein SH2-B. This interaction required the NPTY motif of APS and the LIM domains of Enigma. In NIH-3T3 cells that express the insulin receptor, Enigma...... cytoskeleton organisation, expression of Enigma alone led to the formation of F-actin clusters. Similar alteration in actin cytoskeleton organisation was observed in cells expressing both Enigma and APS with a mutation in the NPTY motif. These results identify Enigma as a novel APS-binding protein and suggest...... that the APS/Enigma complex plays a critical role in actin cytoskeleton organisation....

  4. An analysis of AP600 design features

    International Nuclear Information System (INIS)

    Park, Jong Kyoon; Jang, Moon Heui; Hwang, Yung Dong

    1994-01-01

    In the aspect of engineering, passive safety system concept has improved the safety degree of nuclear power plant. Therefore, the objective of this study is to check on the possibility of the capacity upgrade of nuclear power plant in the case of adopting the passive safety system concept of AP 600. The characteristics of AP 600 are the advanced functions in ECCS, heat removal of containment building and residual heat removal under the passive safety system concept. The result of this study will become the basic data of capacity upgrade of nuclear power plant and will be widely used in second year project. (Author)

  5. An analysis of AP600 design features

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Kyoon; Jang, Moon Heui; Hwang, Yung Dong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); and others

    1994-01-01

    In the aspect of engineering, passive safety system concept has improved the safety degree of nuclear power plant. Therefore, the objective of this study is to check on the possibility of the capacity upgrade of nuclear power plant in the case of adopting the passive safety system concept of AP 600. The characteristics of AP 600 are the advanced functions in ECCS, heat removal of containment building and residual heat removal under the passive safety system concept. The result of this study will become the basic data of capacity upgrade of nuclear power plant and will be widely used in second year project. (Author).

  6. Health in All Policies (HiAP) governance: lessons from network governance.

    Science.gov (United States)

    Khayatzadeh-Mahani, Akram; Ruckert, Arne; Labonté, Ronald; Kenis, Patrick; Akbari-Javar, Mohammad Reza

    2018-05-25

    The Health in All Policies (HiAP) approach requires formal and sustained governance structures and mechanisms to ensure that the policies of various non-health sectors maximize positive and minimize negative impacts on population health. In this paper, we demonstrate the usefulness of a network perspective in understanding and contributing to the effectiveness of HiAP. We undertook an exploratory, qualitative case study of a HiAP structure in Iran, the Kerman province Council of Health and Food Security (CHFS) with diverse members from health and non-health sectors. We analyzed relevant policy texts and interviewed 32 policy actors involved in the CHFS. Data were analyzed using within-case analysis and constant comparative methodology. Our findings suggest that CHFS governance from a network perspective drew in practice on elements of two competing network governance modes: the network administrative organization (NAO) and the lead organization mode. Our results also show that a shift from a hierarchical and market-based mode of interaction to a network logic within CHFS has not yet taken place. In addition, CHFS suffers from large membership and an inability to address complex 'wicked problems', as well as low trust, legitimacy and goal consensus among its members. Drawing on other HiAP studies and commentaries, insights from organization network theory, and in-depth findings from our case study, we conclude that a NAO may be the most effective mode of governance for tackling complex social problems in HiAP structures. Since similar studies are limited, and our single case study may not be transferable across all contexts, we suggest that further research be undertaken to explore HiAP structures from a network perspective in different institutional and cultural settings. With increasing emphasis given to HiAP approaches in national and international health policy discourse, it is important that comparative knowledge about the effectiveness of HiAP governance

  7. HSE management for AP1000 nuclear plant construction in EPC mode

    International Nuclear Information System (INIS)

    He Xiaogang; Wei Zhong

    2010-01-01

    As a new nuclear type, AP1000 will become the development direction of Chinese nuclear project. EPC General Contract mode is favored by nuclear owners both at home and abroad. Therefore, there is necessity for studying HSE management system and method suitable for AP1000 nuclear plant construction (ANPC) based on combination of AP1000 construction characters in EPC mode. This can not only ensure safety for ANPC but also positively promote national nuclear power development. For this reason, based on site HSE management of the first AP1000 nuclear plant under construction, HSE management system and method for ANPC in EPC mode was proposed after analysis of the character of EPC mode and ANPC character. It is hoped that it will be helpful for safe construction for ANPC. (authors)

  8. Containment integrity analysis for the (W) advanced AP600

    International Nuclear Information System (INIS)

    Gagnon, A.F.; Howe, K.S.

    1989-01-01

    This paper reports that since 1987, Westinghouse has been performing containment cooling analyses in support of the Advanced AP600 plant design. This program was intended to verify the feasibility of the passive containment cooling system features of the AP600 design. To support this design, containment analyses of the AP600 containment for a large break LOCA and a large Steam Line Break were performed. The transient results indicate the feasibility of the passive containment design by demonstrating the capability to remove sufficient heat to limit containment atmosphere conditions to within acceptable limits following these postulated accidents. These results also indicate that the PCCS can reduce containment pressure to less than one-quarter design pressure at 24 hours following the most severe accident scenario thereby minimizing containment leakage concerns

  9. A New Photometric Study of Ap and Am Stars in the Infrared

    Energy Technology Data Exchange (ETDEWEB)

    Chen, P. S.; Liu, J. Y.; Shan, H. G., E-mail: chenps@ynao.ac.cn [Yunnan Observatories and Key Laboratory for the Structure and Evolution of Celestial Objects, Chinese Academy of Sciences, Kunming 650011 (China)

    2017-05-01

    In this paper, 426 well known confirmed Ap and Am stars are photometrically studied in the infrared. The 2MASS, Wide-field Infrared Survey Explorer ( WISE ), and IRAS data are employed to make analyses. The results in this paper have shown that in the 1–3 μ m region over 90% Ap and Am stars have no or little infrared excesses, and infrared radiations in the near-infrared from these stars are probably dominated by the free–free emissions. It is also shown that in the 3–12 μ m region, the majority of Ap stars and Am stars have very similar behavior, i.e., in the W 1– W 2 (3.4–4.6 μ m) region, over half of Ap and Am stars have clear infrared excesses, which are possibly due to the binarity, the multiplicity, and/or the debris disk, but in the W 2– W 3 (4.6–12 μ m) region they have no or little infrared excess. In addition, in the 12–22 μ m region, some of Ap stars and Am stars show the infrared excesses and infrared radiations for these Ap and Am stars are probably due to the free–free emissions. In addition, it is seen that the probability of being the binarity, the multiplicity and/or the debris disk for Am stars is much higher than that for Ap stars. Furthermore, it can be seen that, in general, no relations can be found between infrared colors and spectral types either for Ap stars or for Am stars.

  10. A New Photometric Study of Ap and Am Stars in the Infrared

    International Nuclear Information System (INIS)

    Chen, P. S.; Liu, J. Y.; Shan, H. G.

    2017-01-01

    In this paper, 426 well known confirmed Ap and Am stars are photometrically studied in the infrared. The 2MASS, Wide-field Infrared Survey Explorer ( WISE ), and IRAS data are employed to make analyses. The results in this paper have shown that in the 1–3 μ m region over 90% Ap and Am stars have no or little infrared excesses, and infrared radiations in the near-infrared from these stars are probably dominated by the free–free emissions. It is also shown that in the 3–12 μ m region, the majority of Ap stars and Am stars have very similar behavior, i.e., in the W 1– W 2 (3.4–4.6 μ m) region, over half of Ap and Am stars have clear infrared excesses, which are possibly due to the binarity, the multiplicity, and/or the debris disk, but in the W 2– W 3 (4.6–12 μ m) region they have no or little infrared excess. In addition, in the 12–22 μ m region, some of Ap stars and Am stars show the infrared excesses and infrared radiations for these Ap and Am stars are probably due to the free–free emissions. In addition, it is seen that the probability of being the binarity, the multiplicity and/or the debris disk for Am stars is much higher than that for Ap stars. Furthermore, it can be seen that, in general, no relations can be found between infrared colors and spectral types either for Ap stars or for Am stars.

  11. AE8/AP8 Implementations in AE9/AP9, IRBEM, and SPENVIS

    Science.gov (United States)

    2014-02-18

    period applies to orbit generation only; AE8/AP8 utilizes geomagnetic field models from other epochs as specified in the table below.) SHIELDOSE2 model...finite and semi- infinite slab data tables for Bremsstrahlung have been reversed [Heynderickx, private communication, May 2013]. This correction is...Cain, J. C., S. J. Hendricks, R. A. Langel, and W. V. Hudson (1967), A proposed model for the international geomagnetic reference field, 1965, J

  12. AP190L and PDP-KI10: a hardware/software measurement report

    International Nuclear Information System (INIS)

    Maron, N.; Sutherland, G.G.

    1979-01-01

    This report discusses an AP190L array processor (manufactured by Floating Point Systems of Beaverton, Oregon) interfaced to a PDP-10 (Digital Equipment Corporation, Maynard, Mass.). After AP software installation, an analysis of the overhead was performed. The results of these measurements and some conclusions are presented. An AP monitor and software interface were written to minimize the overhead from the PDP-10. A vector extension to the FORTRAN language called FIVE was developed to increase user access to the AP. Some of the problems associated with defining and implementing FIVE are discussed. Its successes and limitations are reviewed. 2 figures, 2 tables

  13. Prognostic value of Angiographic Perfusion Score (APS) following percutaneous interventions in acute coronary syndromes.

    Science.gov (United States)

    Narain, V S; Fischer, L; Puri, A; Sethi, R; Dwivedi, S K

    2013-01-01

    Identifying reperfusion and predicting post procedure risk is important following Percutaneous Coronary Interventions (PCI). An Angiographic Perfusion Score (APS) combining TIMI flow (TFG) and myocardial perfusion (TMPG) grades before and after PCI can accurately measure both epicardial and myocardial perfusion and predict Major Adverse Cardiac Events (MACE). APS was calculated in 226 (88 ST elevation Myocardial Infarction (STEMI) and 138 Non STEMI) patients. Maximum score being 12, reperfusion was defined as failed: 0-3, partial: 4-9, and full APS: 10-12. Thirty day MACE were observed. APS identified reperfusion significantly more than TMPG alone (STEMI: 50.6% vs 11.8% (p APS group (1.8% vs 22.5%) (p APS detects more low risk reperfused patients, post PCI. Copyright © 2012. Published by Elsevier B.V.

  14. Effect of Fe{sub 2}O{sub 3} in Fe{sub 2}O{sub 3}/AP composite particles on thermal decomposition of AP and on burning rate of the composite propellant

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Zhenye [National Special Superfine Powder Engineering Research Center, Nanjing University of Science and Technology, Nanjing, 210094 (China); Nanjing University of Technology, Nanjing (China); Li, Fengsheng; Bai, Huaping [National Special Superfine Powder Engineering Research Center, Nanjing University of Science and Technology, Nanjing, 210094 (China)

    2006-12-15

    A technique of composite processing of Fe{sub 2}O{sub 3} and ammonium perchlorate (AP) was employed in making the propellant. The effects of composite processing of Fe{sub 2}O{sub 3} on catalytic activity, on the thermal decomposition of AP, and on the burning rate of the composite propellant were investigated in this paper. Fe{sub 2}O{sub 3}/AP composite particles were prepared by a novel solvent-nonsolvent method. The results show that AP is successfully coated on the surface of Fe{sub 2}O{sub 3}. Composite processing of Fe{sub 2}O{sub 3} and AP can improve the catalytic activity of Fe{sub 2}O{sub 3}. Fe{sub 2}O{sub 3} exhibits better catalytic effect with increasing Fe{sub 2}O{sub 3} content. The larger interface between Fe{sub 2}O{sub 3} and AP and lower density of composite propellant (with the added Fe{sub 2}O{sub 3}/AP composite particles) are responsible for the enhancement of the catalytic activity of Fe{sub 2}O{sub 3}. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  15. CLEARING MAGNET DESIGN FOR APS-U

    Energy Technology Data Exchange (ETDEWEB)

    Abliz, M.; Grimmer, J.; Jaski, Y.; Westferro, F.; Ramanathan, M.

    2017-06-25

    The Advanced Photon Source is in the process of developing an upgrade (APS-U) of the storage ring. The upgrade will be converting the current double bend achromat (DBA) lattice to a multi-bend achromat (MBA) lattice. In addition, the storage ring will be operated at 6 GeV and 200 mA with regular swap-out injection to keep the stored beam current constant [1]. The swap-out injection will take place with beamline shutters open. For radiation safety to ensure that no electrons can exit the storage ring, a passive method of protecting the beamline and containing the electrons inside the storage ring is proposed. A clearing magnet will be located in all beamline front ends inside the storage ring tunnel. This article will discuss the features and design of the clearing magnet scheme for APS-U.

  16. The Dushak–Erekdag Survey of roAp Stars Tatyana Dorokhova ...

    Indian Academy of Sciences (India)

    South-African Astronomical Observatory (SAAO). Details of the discovery and further studies are given in Kurtz (1990) and Kurtz & Martinez (2000). Some roAp stars have multiple modes of pulsations and they are valuable for asteroseismological studies. Out of the 32 known roAp stars so far, about 84% were discovered in ...

  17. ION EFFECTS IN THE APS PARTICLE ACCUMULATOR RING

    Energy Technology Data Exchange (ETDEWEB)

    Calvey, J.; Harkay, K.; Yao, CY.

    2017-06-25

    Trapped ions in the APS Particle Accumulator Ring (PAR) lead to a positive coherent tune shift in both planes, which increases along the PAR cycle as more ions accumulate. This effect has been studied using an ion simulation code developed at SLAC. After modifying the code to include a realistic vacuum profile, multiple ionization, and the effect of shaking the beam to measure the tune, the simulation agrees well with our measurements. This code has also been used to evaluate the possibility of ion instabilities at the high bunch charge needed for the APS-Upgrade.

  18. Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

    Directory of Open Access Journals (Sweden)

    Qiang Xu

    2016-02-01

    Full Text Available The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH and finite element method (FEM coupling method is used to numerically simulate the fluid and structure interaction (FSI between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

  19. Recessive loss-of-function mutations in AP4S1 cause mild fever-sensitive seizures, developmental delay and spastic paraplegia through loss of AP-4 complex assembly

    DEFF Research Database (Denmark)

    Hardies, Katia; May, Patrick; Djémié, Tania

    2015-01-01

    We report two siblings with infantile onset seizures, severe developmental delay and spastic paraplegia, in whom whole-genome sequencing revealed compound heterozygous mutations in the AP4S1 gene, encoding the σ subunit of the adaptor protein complex 4 (AP-4). The effect of the predicted loss-of-...... in reported patients, highlighting that seizures are part of the clinical manifestation of the AP-4 deficiency syndrome. We also hypothesize that endosomal trafficking is a common theme between heritable spastic paraplegia and some inherited epilepsies....

  20. Visualização do manto cerebral após tratamento de hidrocéfalo congênito: relato de um caso

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Cavalcanti

    1986-06-01

    Full Text Available O propósito deste registro é relatar o caso de recém-nascido com hidrocefalia que, após derivação ventrículo-peritoneal passou a apresentar evolução próxima ao normal do ponto de vista neurológico, bem como visualização à tomografia computadorizada do manto cerebral não observado em exame feito anteriormente.

  1. The modularization construction of piping system installation in AP1000 plant

    International Nuclear Information System (INIS)

    Lu Song; Wang Yuan; Wei Junming

    2012-01-01

    Modularization construction is the main technique used in AP1000 plants, the piping Modularization installation will impact directly to the module construction as the important part of the Modularization construction. After the piping system has took the modularization design in AP1000 plants, some installation works of piping system has moved from the site to fabrication shop. With improving the construction quality and minimizing the time frame of project, the critical paths can be optimized. This paper has analyzed the risk and challenge that met during the modularization construction period of piping systems though introducing the characteristic of modularization construction for AP1000 piping systems, and get construction experiences from the First AP1000 plants in the world, then it will be the firmly basics for the wide application of modularization construction in the future. (authors)

  2. Intermediate-break LOCA analyses for the AP600 design

    International Nuclear Information System (INIS)

    Boyack, B.E.; Lime, J.F.

    1995-01-01

    A postulated double-ended guillotine break of a direct-vessel-injection line in an AP600 plant has been analyzed. This event is characterized as an intermediate break loss-of-coolant accident (IBLOCA). Most of the insights regarding the response of the AP600 safety systems to the postulated accident are derived from calculations performed with the TRAC-PFl/MOD2 code. However, complementary insights derived from a scaled experiment conducted in the ROSA facility, as well as insights based upon calculations by other codes, are also presented. The key processes occurring in an AP600 during a IBLOCA are primary coolant system depressurization, inventory depletion, inventory replacement via emergency core coolant injection, continuous core cooling, and long-term decay heat rejection to the atmosphere. Based upon the calculated and experimental results, the AP600 will not experience a core heat up and will reach a safe shutdown state using only safety-class equipment. Only the early part of the long-term cooling period initiated by In-containment Refueling Water Storage Tank injection was evaluated Thus, the observation that the core is continuously cooled should be verified for the latter phase of the long-term cooling period, the interval when sump injection and containment cooling processes are important

  3. Age-related changes in normal adult pancreas: MR imaging evaluation

    International Nuclear Information System (INIS)

    Sato, Tomohiro; Ito, Katsuyoshi; Tamada, Tsutomu; Sone, Teruki; Noda, Yasufumi; Higaki, Atsushi; Kanki, Akihiko; Tanimoto, Daigo; Higashi, Hiroki

    2012-01-01

    Objective: To investigate age-related changes in normal adult pancreas as identified by magnetic resonance imaging (MRI). Materials and methods: We examined 115 patients without pancreatic diseases (21–90 years) who underwent upper abdominal MRI to evaluate the normal pancreatic MRI findings related to aging. The parameters examined were the pancreatic anteroposterior (AP) diameter, pancreatic lobulation, pancreatic signal intensity (SI), depiction of the main pancreatic duct (MPD), grade of the visual SI decrease on the opposed-phase T1-weighted images compared with in-phase images, and enhancement effect of the pancreas in the arterial phase of dynamic imaging. Results: The pancreatic AP diameter significantly reduced (head, p = 0.0172; body, p = 0.0007; tail, p < 0.0001), and lobulation (p < 0.0001) and parenchymal fatty change (p < 0.0001) became more evident with aging. No significant correlation was observed between aging and pancreatic SI, however the SI on the in-phase T1-weighted images tended to decrease with aging. No significant correlation was observed between aging and the depiction of the MPD as well as aging and contrast enhancement. Conclusion: MRI findings of pancreatic atrophy, lobulation, and fatty degeneration are characteristic changes related to aging, and it is necessary to recognize these changes in the interpretation of abdominal MRI in patients with and without pancreatic disease

  4. Comparison of CPR1000 and AP1000 rod position indication systems

    International Nuclear Information System (INIS)

    Lei Qing

    2009-01-01

    This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication. (authors)

  5. Non-conventional antiphospholipid antibodies in patients with clinical obstetrical APS: Prevalence and treatment efficacy in pregnancies.

    Science.gov (United States)

    Mekinian, Arsène; Bourrienne, Marie-Charlotte; Carbillon, Lionel; Benbara, Amélie; Noémie, Abisror; Chollet-Martin, Sylvie; Tigaizin, Ahmed; Montestruc, Francois; Fain, Olivier; Nicaise-Roland, Pascale

    2016-10-01

    To describe the prevalence of non-conventional APL in patients with obstetrical APS without conventional APL and the impact of treatment on pregnancy outcome. Patients with clinical obstetrical criteria were tested for anti-phosphatidylethanolamine (aPE) IgG/M, anti-prothrombin/phosphatidylserine (anti-PS/PT) IgG/M, and anti-annexin V IgG. Pregnancy losses rates were compared between APS, non-conventional APS, and non-APL and in untreated pregnancies to treated ones for each group. Using the cutoffs (ROC), 65/96 (68%) patients have been considered as non-conventional APS and compared to 83 APS and 31 patients without APL. The obstetrical history in non-conventional APS did not differ in comparison to confirmed APS. The frequencies of anti-annexin V IgG antibodies tended to be more frequent in non-conventional APS (88% versus 73%; p = 0.06), and those of anti-PE IgG and M were similar. The anti-PS/PT IgG and M antibodies were more frequent in confirmed APS than in non-conventional APS (63% and 37% versus 4% and 5%, respectively, p APS were compared with 81 pregnancies of confirmed APS and 132 pregnancies from non-APL group. Out of 474, 136 (29%) patients have been treated during pregnancies, and treatment significantly increased the rate of live birth (26% in untreated versus 72% in treated pregnancies, p APS and non-conventional APS, with odds ratio at 3.3 (95% CI: 1.8-6.1) and 6.9 (95% CI: 3.9-12.3) (p = 0.49) and significantly more important for the 2 APS groups pooled versus non-APL group [OR at 1.9 (95% CI: 1.1-3.5) for non-APL group versus 5.3 (95% CI: 3.5-8.1) for APS groups, p = 0.0025]. In this study, 68% of patients with clinical criteria for obstetrical APS seronegative for conventional APL have non-conventional APL. These patients have a significant decrement of pregnancy losses if they receive treatment for APS during their pregnancy. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Introduction to sump screen downstream effect analysis of AP1000 nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Qinghua; Liu Yu; Chai Guohan

    2010-01-01

    The design of AP1000 takes into account the potential impact of debris clogging on sump screen. In this article, the technical background of sump screen issue and the design characteristics of AP1000 to address the sump screen blockage issue are introduced. The article focuses on the 'downstream effect' analysis method, acceptance criteria and analysis result of AP1000 sump screen. Although the design of AP1000 is different with traditional PWR, the author expects to bring some reference to advance the downstream effect analysis in China through the introduction. (authors)

  7. Tank characterization report for double-shell Tank 241-AP-107

    International Nuclear Information System (INIS)

    DeLorenzo, D.S.; Simpson, B.C.

    1994-01-01

    The purpose of this tank characterization report is to describe and characterize the waste in Double-Shell Tank 241-AP-107 based on information gathered from various sources. This report summarizes the available information regarding the waste in Tank 241-AP-107, and arranges it in a useful format for making management and technical decisions concerning this particular waste tank. In addition, conclusion and recommendations based on safety and further characterization needs are given. Specific objectives reached by the sampling and characterization of the waste in Tank 241-AP-107 are: Contribute toward the fulfillment of the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-44-05 concerning the characterization of Hanford Site high-level radioactive waste tanks; Complete safety screening of the contents of Tank 241-AP-107 to meet the characterization requirements of the Defense Nuclear Facilities Safety board (DNFSB) Recommendation 93-5; and Provide tank waste characterization to the Tank Waste Remediation System (TWRS) Program Elements in accordance with the TWRS Tank Waste Analysis Plan

  8. Argonne National Laboratory high performance network support of APS experiments

    International Nuclear Information System (INIS)

    Knot, M.J.; McMahon, R.J.

    1996-01-01

    Argonne National Laboratory is currently positioned to provide access to high performance regional and national networks. Much of the impetus for this effort is the anticipated needs of the upcoming experimental program at the APS. Some APS collaborative access teams (CATs) are already pressing for network speed improvements and security enhancements. Requirements range from the need for high data rate, secure transmission of experimental data, to the desire to establish a open-quote open-quote virtual experimental environment close-quote close-quote at their home institution. In the near future, 155 megabit/sec (Mb/s) national and regional asynchronous transfer mode (ATM) networks will be operational and available to APS users. Full-video teleconferencing, virtual presence operation of experiments, and high speed, secure transmission of data are being tested and, in some cases, will be operational. We expect these efforts to enable a substantial improvement in the speed of processing experimental results as well as an increase in convenience to the APS experimentalist. copyright 1996 American Institute of Physics

  9. AP Geography, Environmental Science Thrive

    Science.gov (United States)

    Robelen, Erik W.

    2012-01-01

    Geography may not be particularly known as a hot topic among today's students--even some advocates suggest it suffers from an image problem--but by at least one measure, the subject is starting to come into its own. Across more than 30 topics covered in the Advanced Placement (AP) program, participation in geography is rising faster than any…

  10. Synthesis and binding properties of new selective ligands for the nucleobase opposite the AP site.

    Science.gov (United States)

    Abe, Yukiko; Nakagawa, Osamu; Yamaguchi, Rie; Sasaki, Shigeki

    2012-06-01

    DNA is continuously damaged by endogenous and exogenous factors such as oxidative stress or DNA alkylating agents. These damaged nucleobases are removed by DNA N-glycosylase and form apurinic/apyrimidinic sites (AP sites) as intermediates in the base excision repair (BER) pathway. AP sites are also representative DNA damages formed by spontaneous hydrolysis. The AP sites block DNA polymerase and a mismatch nucleobase is inserted opposite the AP sites by polymerization to cause acute toxicities and mutations. Thus, AP site specific compounds have attracted much attention for therapeutic and diagnostic purposes. In this study, we have developed nucleobase-polyamine conjugates as the AP site binding ligand by expecting that the nucleobase part would play a role in the specific recognition of the nucleobase opposite the AP site by the Watson-Crick base pair formation and that the polyamine part should contribute to the access of the ligand to the AP site by a non-specific interaction to the DNA phosphate backbone. The nucleobase conjugated with 3,3'-diaminodipropylamine (A-ligand, G-ligand, C-ligand, T-ligand and U-ligand) showed a specific stabilization of the duplex containing the AP site depending on the complementary combination with the nucleobase opposite the AP site; that is A-ligand to T, G-ligand to C, C-ligand to G, T- and U-ligand to A. The thermodynamic binding parameters clearly indicated that the specific stabilization is due to specific binding of the ligands to the complementary AP site. These results have suggested that the complementary base pairs of the Watson-Crick type are formed at the AP site. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. APS- and XPS-investigations of vanadium, vanadium carbide and graphite

    Energy Technology Data Exchange (ETDEWEB)

    Bradshaw, A M; Krause, U [Technische Univ. Muenchen (F.R. Germany). Inst. fuer Physikalische Chemie und Theoretische Chemie

    1975-11-01

    Soft X-ray appearance potential spectroscopy (APS) and X-ray photoelectron spectroscopy (XPS) have been used to study vanadium, vanadium carbide, and graphite. The chemical shifts for vanadium carbide with respect to metallic vanadium and graphite are compared for the two methods. The Csub(K) structure in APS and the valence band in XPS for vanadium carbide show good agreement with the band structure calculations of Neckel and co-workers. Using the band structure calculations of Painter et al. it is also shown how the multi-peak structure in the APS spectrum of graphite is possibly due to density of states effects. It would therefore appear that plasmon coupling plays only a minor role.

  12. Mixer-settler runs for the evaluation of tri-iso-amyl phosphate (TiAP) as an alternate extractant to tri-n-butyl phosphate (TBP) for reprocessing applications

    International Nuclear Information System (INIS)

    Suresh, A.; Sreenivasulu, B.; Jayalakshmi, S.; Subramaniam, S.; Sabharwal, K.N.; Sivaraman, N.; Nagarajan, K.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2015-01-01

    As part of the studies on the development of alternate extractants for fast reactor fuel reprocessing, a mixer-settler facility for performing counter-current solvent extraction runs with radioactive materials has been set up and commissioned in our laboratory for flow sheet development experiments. Mixer-settler runs were carried out with 1.1 M TiAP/Heavy Normal Paraffin (HNP) as the solvent using the above facility to test the equipment as well as the behaviour of the solvent for continuous solvent extraction processes. Stage profile data generated for the extraction and stripping of nitric acid with TiAP based solvent have been reported. Studies carried out on the continuous counter-current extraction and stripping of U(VI) for 1.1 M TiAP/HNP-U(VI)-HNO 3 system under high solvent loading conditions are also reported in this paper. Overall and stage-wise mass balance data for the above runs are also discussed.

  13. Mixer-settler runs for the evaluation of tri-iso-amyl phosphate (TiAP) as an alternate extractant to tri-n-butyl phosphate (TBP) for reprocessing applications

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, A.; Sreenivasulu, B.; Jayalakshmi, S.; Subramaniam, S.; Sabharwal, K.N.; Sivaraman, N.; Nagarajan, K.; Srinivasan, T.G.; Vasudeva Rao, P.R. [Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2015-05-01

    As part of the studies on the development of alternate extractants for fast reactor fuel reprocessing, a mixer-settler facility for performing counter-current solvent extraction runs with radioactive materials has been set up and commissioned in our laboratory for flow sheet development experiments. Mixer-settler runs were carried out with 1.1 M TiAP/Heavy Normal Paraffin (HNP) as the solvent using the above facility to test the equipment as well as the behaviour of the solvent for continuous solvent extraction processes. Stage profile data generated for the extraction and stripping of nitric acid with TiAP based solvent have been reported. Studies carried out on the continuous counter-current extraction and stripping of U(VI) for 1.1 M TiAP/HNP-U(VI)-HNO{sub 3} system under high solvent loading conditions are also reported in this paper. Overall and stage-wise mass balance data for the above runs are also discussed.

  14. Amphioxus and lamprey AP-2 genes: implications for neural crest evolution and migration patterns

    Science.gov (United States)

    Meulemans, Daniel; Bronner-Fraser, Marianne

    2002-01-01

    The neural crest is a uniquely vertebrate cell type present in the most basal vertebrates, but not in cephalochordates. We have studied differences in regulation of the neural crest marker AP-2 across two evolutionary transitions: invertebrate to vertebrate, and agnathan to gnathostome. Isolation and comparison of amphioxus, lamprey and axolotl AP-2 reveals its extensive expansion in the vertebrate dorsal neural tube and pharyngeal arches, implying co-option of AP-2 genes by neural crest cells early in vertebrate evolution. Expression in non-neural ectoderm is a conserved feature in amphioxus and vertebrates, suggesting an ancient role for AP-2 genes in this tissue. There is also common expression in subsets of ventrolateral neurons in the anterior neural tube, consistent with a primitive role in brain development. Comparison of AP-2 expression in axolotl and lamprey suggests an elaboration of cranial neural crest patterning in gnathostomes. However, migration of AP-2-expressing neural crest cells medial to the pharyngeal arch mesoderm appears to be a primitive feature retained in all vertebrates. Because AP-2 has essential roles in cranial neural crest differentiation and proliferation, the co-option of AP-2 by neural crest cells in the vertebrate lineage was a potentially crucial event in vertebrate evolution.

  15. Comparison and analysis for item classifications between AP1000 and traditional PWR

    International Nuclear Information System (INIS)

    Luo Shuiyun; Liu Xiaoyan

    2012-01-01

    The comparison and analysis for the safety classification, seismic category, code classification and QA classification between AP1000 and traditional PWR were presented. The safety could be guaranteed and the construction and manufacture costs could be cut down since all sorts of AP1000 classifications. It is suggested that the QA classification and the QA requirements correspond to the national conditions should be drafted in the process of AP1000 domestication. (authors)

  16. Conditional deletion of AP-2β in mouse cranial neural crest results in anterior segment dysgenesis and early-onset glaucoma

    Directory of Open Access Journals (Sweden)

    Vanessa B. Martino

    2016-08-01

    Full Text Available Anterior segment dysgenesis (ASD encompasses a group of developmental disorders in which a closed angle phenotype in the anterior chamber of the eye can occur and 50% of patients develop glaucoma. Many ASDs are thought to involve an inappropriate patterning and migration of the periocular mesenchyme (POM, which is derived from cranial neural crest cells (NCCs and mesoderm. Although, the mechanism of this disruption is not well understood, a number of transcriptional regulatory molecules have previously been implicated in ASDs. Here, we investigate the function of the transcription factor AP-2β, encoded by Tfap2b, which is expressed in NCCs and their derivatives. Wnt1-Cre-mediated conditional deletion of Tfap2b in NCCs resulted in post-natal ocular defects typified by opacity. Histological data revealed that the conditional AP-2β NCC knockout (KO mutants exhibited dysgenesis of multiple structures in the anterior segment of the eye including defects in the corneal endothelium, corneal stroma, ciliary body and disruption in the iridocorneal angle with adherence of the iris to the cornea. We further show that this phenotype leads to a significant increase in intraocular pressure and a subsequent loss of retinal ganglion cells and optic nerve degeneration, features indicative of glaucoma. Overall, our findings demonstrate that AP-2β is required in the POM for normal development of the anterior segment of the eye and that the AP-2β NCC KO mice might serve as a new and exciting model of ASD and glaucoma that is fully penetrant and with early post-natal onset.

  17. Power supply control units for APS ring magnets

    International Nuclear Information System (INIS)

    Despe, O.D.

    1990-01-01

    The APS storage ring (1104 meters) is divided into 40 sectors. Each sector has 38 magnet coils in five magnet bases. Every alternate sector has an additional quadrupole magnet for skew correction. AR the main dipole magnets, two in each sector are connected in series and fed from one power supply unit. A base is controlled by one power supply control unit (PSCU). Each PSCU is connected to the host computer via a local area network (LAN). This note discusses the hardware configuration of the typical power supply control system used by the APS magnets and the software commands supported by the PSCU

  18. A dual potassium channel activator improves repolarization reserve and normalizes ventricular action potentials

    DEFF Research Database (Denmark)

    Calloe, Kirstine; Di Diego, José M; Hansen, Rie Schultz

    2016-01-01

    in cultured canine cardiac myocytes and determined whether a dual K(+) current activator can normalize K(+) currents and restore action potential (AP) configuration. METHODS AND RESULTS: Ventricular myocytes were isolated and cultured for up to 48h. Current and voltage clamp recordings were made using patch...... of EADs. Our results suggest a potential benefit of K(+) current activators under conditions of reduced repolarization reserve including heart failure....

  19. Comparison of a CCD and an APS for soft x-ray diffraction

    OpenAIRE

    Stewart, G.; Bates, R.; Blue, A.; Clark, A.; Dhesi, S.S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost.\\ud \\ud The AP...

  20. Dyslipidemia and its relationship with antiphospholipid antibodies in APS patients in North Kerala.

    Science.gov (United States)

    Sadanand, Shajit; Paul, Binoy J; Thachil, Emil J; Meletath, Rejadheesh

    2016-12-01

    Antiphospholipid antibody syndrome (APS) is one of the most common acquired thrombophilic disorders resulting in arterial and venous thromboses. APS is a major cause for cerebrovascular accidents or stokes, myocardial infarction, venous thromboembolism and recurrent abortions/pregnancy losses especially in young patients. APS patients have an increased risk of atherosclerotic cardiovascular events. There are only two studies on lipid abnormalities in APS patients. None of them have studied the relationship between individual laboratory tests for APS and lipid profile abnormalities. Here we describe the significance of the relationship between various APS tests and lipid profile abnormalities in a subset of APS patients who presented with arterial thrombosis in a tertiary care hospital. The study was conducted at Government Medical College, which is a tertiary care referral hospital. All patients who presented to the medicine department with APS during a two-year period were studied. A patient was considered to be positive for anticardiolipin (aCL) antibody or anti-β2 glycoprotein (anti-β2G) if the titer was more than 15 IU/mL, and a high titer was considered to be more than 40 IU/mL for Immunoglobulin (lg) IgG and IgM isotypes. The fasting lipid profile was measured in all patients, and lipid profile abnormalities were defined with cutoffs of low-density lipoprotein (LDL) levels of >150 mg/dL, triglyceride (TG) levels of >150 mg/dL, and high-density lipoprotein (HDL) levels of APS, aCL IgG and IgM and anti-β2G IgG and IgM, were determined by statistical analysis. The study population included 77 APS patients, with 53% of patients between 20 and 40 years. The commonest abnormality in the lipid profile test was elevated TG levels of >150 mg/dL in 51.9% of the patients, followed by low HDL levels (150 mg/dL) in 40.2% of the patients. There was a statistically significant relationship between anti-β2G IgG levels and HDL and LDL levels, but not TG levels. Only LDL

  1. What do we know about the cardiac valve lesion in the antiphospholipid syndrome (APS)?

    Science.gov (United States)

    Amigo, M-C

    2014-10-01

    Heart valve disease (HVD) is the most common cardiac manifestation in the antiphospholipid syndrome (APS). Valve lesions should be described according to the established definition. HVD is progressive despite anticoagulant/antiplatelet treatments. Around 4-6% of patients with HVD in APS will require valve replacement surgery, which is considered a very high risk procedure in APS. Unfortunately, no recommendations regarding medical treatment of antiphospholipid antibodies-associated HVD can be made at this moment. There are evidence-based data and strong pathophysiologic rationale for considering HVD as a manifestation of APS. Thus, HVD should be included as a criterion of definite APS. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. Tank 241-AP-104 Grab Sampling and Analysis Plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    2000-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for samples obtained from tank 241-AP-104. The purpose of this sampling event is to obtain information about the characteristics of the contents of 241-AP-104 required to provide sample material to the Waste Treatment Contractor. Grab samples will be obtained from riser 001 to provide sufficient material for the chemical analyses and tests required to satisfy these data quality objectives and ICD-23. The 222-S Laboratory will receive samples; composite the samples; perform chemical analyses on composite samples; and provide samples to the Waste Treatment Contractor and the Process Chemistry Laboratory. The Process Chemistry Laboratory at the 222-S Laboratory Complex will perform process tests to evaluate the behavior of the 241-AP-104 waste undergoing the retrieval and treatment scenarios defined in the applicable DQOs. The Waste Treatment Contractor will perform process verification and waste form qualification tests. Requirements for analyses of samples originating in the L and H DQO process tests will be documented in the corresponding test plan (Person 2000) and are not within the scope of this SAP. This report provides the general methodology and procedures to be used in the preparation, retrieval, transport, analysis, and reporting of results from grab samples retrieved from tank 241-AP-104

  3. [Cloning, subcellular localization, and heterologous expression of ApNAC1 gene from Andrographis paniculata].

    Science.gov (United States)

    Wang, Jian; Qi, Meng-Die; Guo, Juan; Shen, Ye; Lin, Hui-Xin; Huang, Lu-Qi

    2017-03-01

    Andrographis paniculata is widely used as medicinal herb in China for a long time and andrographolide is its main medicinal constituent. To investigate the underlying andrographolide biosynthesis mechanisms, RNA-seq for A. paniculata leaves with MeJA treatment was performed. In A. paniculata transcriptomic data, the expression pattern of one member of NAC transcription factor family (ApNAC1) matched with andrographolide accumulation. The coding sequence of ApNAC1 was cloned by RT-PCR, and GenBank accession number was KY196416. The analysis of bioinformatics showed that the gene encodes a peptide of 323 amino acids, with a predicted relative molecular weight of 35.9 kDa and isoelectric point of 6.14. To confirm the subcellular localization, ApNAC1-GFP was transiently expressed in A. paniculata protoplast. The results indicated that ApNAC1 is a nucleus-localized protein. The analysis of real-time quantitative PCR revealed that ApNAC1 gene predominantly expresses in leaves. Compared with control sample, its expression abundance sharply increased with methyl jasmonate treatment. Based on its expression pattern, ApNAC1 gene might involve in andrographolide biosynthesis. ApNAC1 was heterologously expressed in Escherichia coli and recombinant protein was purified by Ni-NTA agarose. Further study will help us to understand the function of ApNAC1 in andrographolide biosynthesis. Copyright© by the Chinese Pharmaceutical Association.

  4. Magnetic Measurements of Storage Ring Magnets for the APS Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Doose, C.; Dejus, R.; Jaski, M.; Jansma, W.; Collins, J.; Donnelly, A.; Liu, J.; Cease, H.; Decker, G.; Jain, A.; DiMarco, J.

    2017-06-01

    Extensive prototyping of storage ring magnets is ongoing at the Advanced Photon Source (APS) in support of the APS Multi-Bend Achromat (MBA) upgrade project (APS-U) [1]. As part of the R&D activities four quadrupole magnets with slightly different geometries and pole tip materials, and one sextupole magnet with vanadium permendur (VP) pole tips were designed, built and tested. Magnets were measured individually using a rotating coil and a Hall probe for detailed mapping of the magnetic field. Magnets were then assembled and aligned relative to each other on a steel support plate and concrete plinth using precision machined surfaces to gain experience with the alignment method chosen for the APS-U storage ring magnets. The required alignment of magnets on a common support structure is 30 μm rms. Measurements of magnetic field quality, strength and magnet alignment after subjecting the magnets and assemblies to different tests are presented.

  5. State-of-the-Art developments in accelerator controls at the APS

    International Nuclear Information System (INIS)

    Lenkszus, F.

    1999-01-01

    The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and fiber optics. Examples of the use of these technologies will also be included. Finally, every modern accelerator control system of any size requires networking. Features of the APS accelerator controls network will be discussed

  6. AP1000{sup R} severe accident features and post-Fukushima considerations

    Energy Technology Data Exchange (ETDEWEB)

    Scobel, J. H.; Schulz, T. L.; Williams, M. G. [Westinghouse Electric Company, LLC, 1000 Westinghouse Dr., Cranberry Township, PA 16066 (United States)

    2012-07-01

    The AP1000{sup R} passive nuclear power plant is uniquely equipped to withstand an extended station blackout scenario such as the events following the earthquake and tsunami at Fukushima without compromising core and containment integrity. The AP1000 plant shuts down the reactor, cools the core, containment and spent fuel pool for more than 3 days using passive systems that do not require AC or DC power or operator actions. Following this passive coping period, minimal operator actions are needed to extend the operation of the passive features to 7 days using installed equipment. To provide defense-in-depth for design extension conditions, the AP1000 plant has engineered features that mitigate the effects of core damage. Engineered features retain damaged core debris within the reactor vessel as a key feature. Other aspects of the design protect containment integrity during severe accidents, including unique features of the AP1000 design relative to passive containment cooling with water and air, and hydrogen management. (authors)

  7. Antiphospholipid syndrome (APS) revisited: Would migraine headaches be included in future classification criteria?

    Science.gov (United States)

    Noureldine, Mohammad Hassan A; Haydar, Ali A; Berjawi, Ahmad; Elnawar, Rody; Sweid, Ahmad; Khamashta, Munther A; Hughes, Graham R V; Uthman, Imad

    2017-02-01

    Headaches have been extensively reported in Antiphospholipid syndrome (APS)/Antiphospholipid antibodies (aPL)-positive patients. The aim of this study was to highlight the prevalence of headaches among APS/aPL-positive patients and discuss its association with laboratory, clinical and imaging findings. We searched the literature through Google Scholar and PubMed for publications on the epidemiology, pathogenesis, laboratory, imaging and clinical findings, and management of headaches in APS/aPL-positive patients. The following keywords were used: Antiphospholipid, Hughes syndrome, anticardiolipin, lupus anticoagulant, anti-β2 glycoprotein I, headache, migraine, tension, and cluster. All reports published between 1969 and 2015 were included. Migraine is the most commonly reported type of headache in APS/aPL-positive patients. Thrombotic and platelet dysfunction hypotheses have been studied to uncover the pathogenic role of aPL in the development of headaches. Several studies are reporting higher levels of aPL in primary and secondary APS migraineurs, but only few reached statistical significance. Migraine patients without clinical signs/symptoms of cerebral infarction rarely show positive imaging findings. Digital subtraction angiography shows promise in demonstrating small vascular lesions otherwise not detected on computed tomography, magnetic resonance imaging, or cerebral angiograms. Although it may be solitary and harmless in many cases, the deleterious effect of migraine on the quality of life of APS patients prompts rapid diagnosis and proper management. An anticoagulation trial is advisable in APS patients with migraine as many cases of severe, refractory migraine resolved with anticoagulation therapy. The profile of migraine headaches discussed in this study permits its candidacy for inclusion in future APS classification criteria.

  8. HPV16 E6 and E6AP differentially cooperate to stimulate or augment Wnt signaling

    International Nuclear Information System (INIS)

    Sominsky, Sophia; Kuslansky, Yael; Shapiro, Beny; Jackman, Anna; Haupt, Ygal; Rosin-Arbesfeld, Rina; Sherman, Levana

    2014-01-01

    The present study investigated the roles of E6 and E6AP in the Wnt pathway. We showed that E6 levels are markedly reduced in cells in which Wnt signaling is activated. Coexpression of wild-type or mutant E6AP (C820A) in Wnt-activated cells stabilized E6 and enhanced Wnt/β-catenin/TCF transcription. Expression of E6AP alone in nonstimulated cells elevated β-catenin level, promoted its nuclear accumulation, and activated β-catenin/TCF transcription. A knockdown of E6AP lowered β-catenin levels. Coexpression with E6 intensified the activities of E6AP. Further experiments proved that E6AP/E6 stabilize β-catenin by protecting it from proteasomal degradation. This function was dependent on the catalytic activity of E6AP, the kinase activity of GSK3β and the susceptibility of β-catenin to GSK3β phosphorylation. Thus, this study identified E6AP as a novel regulator of the Wnt signaling pathway, capable of cooperating with E6 in stimulating or augmenting Wnt/β-catenin signaling, thereby possibly contributing to HPV carcinogenesis. - Highlights: • The roles of E6 and E6AP in the Wnt pathway were investigated. • E6AP stabilizes E6 and enhances E6 activity in augmentation of Wnt signaling. • E6AP cooperates with E6 to stabilize β-catenin and stimulate Wnt/β-catenin signaling. • E6AP and E6 act through different mechanisms to augment or stimulate Wnt signaling

  9. HPV16 E6 and E6AP differentially cooperate to stimulate or augment Wnt signaling

    Energy Technology Data Exchange (ETDEWEB)

    Sominsky, Sophia, E-mail: sophia.tab@gmail.com [Department of Clinical Microbiology and Immunology, Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978 (Israel); Kuslansky, Yael, E-mail: ykuslansky@gmail.com [Department of Clinical Microbiology and Immunology, Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978 (Israel); Shapiro, Beny, E-mail: benyshap@gmail.com [Department of Clinical Microbiology and Immunology, Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978 (Israel); Jackman, Anna, E-mail: jackman@post.tau.ac.il [Department of Clinical Microbiology and Immunology, Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978 (Israel); Haupt, Ygal, E-mail: ygal.haupt@petermac.org [Research Division, The Peter MacCallum Cancer Centre, East Melbourne (Australia); Rosin-Arbesfeld, Rina, E-mail: arina@post.tau.ac.il [Department of Clinical Microbiology and Immunology, Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978 (Israel); Sherman, Levana, E-mail: lsherman@post.tau.ac.il [Department of Clinical Microbiology and Immunology, Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978 (Israel)

    2014-11-15

    The present study investigated the roles of E6 and E6AP in the Wnt pathway. We showed that E6 levels are markedly reduced in cells in which Wnt signaling is activated. Coexpression of wild-type or mutant E6AP (C820A) in Wnt-activated cells stabilized E6 and enhanced Wnt/β-catenin/TCF transcription. Expression of E6AP alone in nonstimulated cells elevated β-catenin level, promoted its nuclear accumulation, and activated β-catenin/TCF transcription. A knockdown of E6AP lowered β-catenin levels. Coexpression with E6 intensified the activities of E6AP. Further experiments proved that E6AP/E6 stabilize β-catenin by protecting it from proteasomal degradation. This function was dependent on the catalytic activity of E6AP, the kinase activity of GSK3β and the susceptibility of β-catenin to GSK3β phosphorylation. Thus, this study identified E6AP as a novel regulator of the Wnt signaling pathway, capable of cooperating with E6 in stimulating or augmenting Wnt/β-catenin signaling, thereby possibly contributing to HPV carcinogenesis. - Highlights: • The roles of E6 and E6AP in the Wnt pathway were investigated. • E6AP stabilizes E6 and enhances E6 activity in augmentation of Wnt signaling. • E6AP cooperates with E6 to stabilize β-catenin and stimulate Wnt/β-catenin signaling. • E6AP and E6 act through different mechanisms to augment or stimulate Wnt signaling.

  10. Overview of the advanced photon source (APS)

    International Nuclear Information System (INIS)

    White, M.M.

    1994-01-01

    The Advanced Photon Source (APS) is a state-of-the-art synchrotron light source facility dedicated to the production of extremely brilliant x-ray beams for research. Its super-intense x-ray beams will be used in many areas of research including industrial research, biological and medical research, defense-related research, and basic research. The APS x-ray beams will allow scientists to study smaller samples, more complex systems, faster reactions and processes, and gather data at a greater level of detail than has been possible to date. Creation of these beams begins with electron production by an electron gun with a thermionic cathode. The electrons are accelerated to 200 MeV by a linear accelerator (linac) and then impinge on a tungsten target, resulting in electron-positron pair production. The positrons are accelerated to 450 MeV in the remainder of the linac, then accumulated, damped, and transferred to a synchrotron that increases their energy to 7 GeV. The 7-GeV positrons are injected into a storage ring, where they pass through special magnets that cause them to emit x-rays of the desired quality. Construction at ANL is nearly complete at this time, and the APS will begin operating for users in 1996. The accelerator and experimental facilities are described in this paper, and a brief overview of some of the experimental programs is given

  11. The APS control system network upgrade

    International Nuclear Information System (INIS)

    Sidorowicz, K. v.; Leibfritz, D.; McDowell, W. P.

    1999-01-01

    When it was installed,the Advanced Photon Source (APS) control system network was at the state-of-the-art. Different aspects of the system have been reported at previous meetings [1,2]. As loads on the controls network have increased due to newer and faster workstations and front-end computers, we have found performance of the system declining and have implemented an upgraded network. There have been dramatic advances in networking hardware in the last several years. The upgraded APS controls network replaces the original FDDI backbone and shared Ethernet hubs with redundant gigabit uplinks and fully switched 10/100 Ethernet switches with backplane fabrics in excess of 20 Gbits/s (Gbps). The central collapsed backbone FDDI concentrator has been replaced with a Gigabit Ethernet switch with greater than 30 Gbps backplane fabric. Full redundancy of the system has been maintained. This paper will discuss this upgrade and include performance data and performance comparisons with the original network

  12. Expansion and Functional Divergence of AP2 Group Genes in Spermatophytes Determined by Molecular Evolution and Arabidopsis Mutant Analysis

    Directory of Open Access Journals (Sweden)

    Pengkai Wang

    2016-09-01

    Full Text Available The APETALA2 (AP2 genes represent the AP2 group within a large group of DNA-binding proteins called AP2/EREBP. The AP2 gene is functional and necessary for flower development, stem cell maintenance, and seed development, whereas the other members of AP2 group redundantly affect flowering time. Here we study the phylogeny of AP2 group genes in spermatophytes. Spermatophyte AP2 group genes can be classified into AP2 and TOE types, six clades, and we found that the AP2 group homologs in gymnosperms belong to the AP2 type, whereas TOE types are absent, which indicates the AP2 type gene are more ancient and TOE type was split out of AP2 type and losing the major function. In Brassicaceae, the expansion of AP2 and TOE type lead to the gene number of AP2 group were up to six. Purifying selection appears to have been the primary driving force of spermatophyte AP2 group evolution, although positive selection occurred in the AP2 clade. The transition from exon to intron of AtAP2 in Arabidopsis mutant leads to the loss of gene function and the same situation was found in AtTOE2. Combining this evolutionary analysis and published research, the results suggest that typical AP2 group genes may first appear in gymnosperms and diverged in angiosperms, following expansion of group members and functional differentiation. In angiosperms, AP2 genes (AP2 clade inherited key functions from ancestors and other genes of AP2 group lost most function but just remained flowering time controlling in gene formation. In this study, the phylogenies of AP2 group genes in spermatophytes was analyzed, which supported the evidence for the research of gene functional evolution of AP2 group.

  13. Energetics and dynamics of the non-natural fluorescent 4AP:DAP base pair

    KAUST Repository

    Chawla, Mohit

    2018-01-02

    The fluorescent non-natural 4-aminophthalimide (4AP) base, when paired to the complementary 2,4-diaminopyrimidine (DAP) nucleobase, is accommodated in a B-DNA duplex being efficiently recognized and incorporated by DNA polymerases. To complement the experimental studies and rationalize the impact of the above non-natural bases on the structure, stability and dynamics of nucleic acid structures, we performed quantum mechanics (QM) calculations along with classical molecular dynamics (MD) simulations. QM calculations were initially focused on the geometry and energetics of the 4AP:DAP non-natural pair and of H-bonded base pairs between 4AP and all the natural bases in their classical Watson-Crick geometries. The QM calculations indicate that the 4AP:DAP pair, despite the fact that it can form 3 H-bonds in a classic Watson-Crick geometry, has a stability comparable to the A:T pair. Then, we extended the study to reverse Watson-Crick geometries, characteristic of parallel strands. MD simulations were carried out on two 13-mer DNA duplexes, featuring a central 4AP:DAP or A:T pair, respectively. No major structural deformation of the duplex was observed during the MD simulation. Snapshots from the MD simulations were subjected to QM calculations to investigate the 4AP:DAP interaction energy when embedded into a duplex structure, and to investigate the impact of the two non-natural bases on the stacking interactions with adjacent bases in the DNA duplex. We found a slight increase in stacking interactions involving the 4AP:DAP pair, counterbalanced by a moderate decrease in H-bonding interactions of the 4AP:DAP and of the adjacent base pairs in the duplex. The results of our study are in agreement with experimental data and complement them by providing an insight into which factors contribute positively and which factors contribute negatively to the structural compatibility of the fluorescent 4AP:DAP pair with a B-DNA structure.

  14. Development of the Assistance to Participate Scale (APS) for children's play and leisure activities.

    Science.gov (United States)

    Bourke-Taylor, H; Law, M; Howie, L; Pallant, J F

    2009-09-01

    This paper describes the development and psychometric evaluation of the Assistance to Participate Scale (APS). The APS measures the assistance that a school-aged child with a disability requires to participate in play and leisure activities from the primary carer's perspective. Mixed methodology using an instrument design model was used to complete two studies. First, a qualitative research design was used to generate items and scoring criteria for the APS. Second, a quantitative study evaluated the instrument using data collected from 152 mothers with children aged 5-18 years. Statistical analysis assessed the underlying structure, internal consistency and construct validity of the APS. Exploratory factor analysis revealed two correlated components, reflecting home-based and community-based play activities. Both subscales and the total APS scale showed good internal consistency. The APS correlated as predicted with individual domains and overall scores for other validated measures (Pediatric Evaluation of Disability Inventory caregiver scales and Pediatric Quality of Life Inventory) with correlations ranging from rho = 0.42 to rho = 0.77. The APS was able to discriminate between groups of children based on type of schooling (regular or segregated), need for equipment/assistive devices, frequency of lifting and disability. The APS provides professionals with a brief psychometrically sound tool that measures the amount of caregiver assistance provided to a child with a disability to participate in play and recreation. The APS may be used as an outcome measure and to evaluate and predict the amount and type of additional assistance families need to facilitate their child's participation in an important aspect of the child's daily life and development: play and recreation.

  15. Understanding and Using the New Guided-Inquiry AP Chemistry Laboratory Manual

    Science.gov (United States)

    Cacciatore, Kristen L.

    2014-01-01

    To support teaching and learning in the advanced placement (AP) chemistry laboratory, the College Board published a laboratory manual, "AP Chemistry Guided-Inquiry Experiments: Applying the Science Practices," in 2013 as part of the redesigned course. This article provides a discussion of the rationale for the existence of the manual as…

  16. Panel Discussion : Report of the APS Ad-Hoc Committee on LGBT Issues

    Science.gov (United States)

    Atherton, Tim; Barthelemy, Ramon; Garmon, Savannah; Reeves, Kyle; APS Ad-Hoc Committee on LGBT Issues Team

    Following the presentation of the findings and recommendations of the APS Ad-Hoc Committee on LGBT Issues (C-LGBT) by Committee Chair Michael Falk, a panel discussion will be held featuring several members of the committee. The discussion will focus on how APS can best ensure the recommendations of the committee are carried out in a timely fashion and other ideas on future APS efforts toward LGBT inclusion in physics. Discussion topics will also include the research and other input that shaped the committee's findings and recommendations.

  17. Postural tachycardia syndrome (POTS) and other autonomic disorders in antiphospholipid (Hughes) syndrome (APS).

    Science.gov (United States)

    Schofield, J R; Blitshteyn, S; Shoenfeld, Y; Hughes, G R V

    2014-06-01

    Antiphospholipid syndrome (APS) is an autoimmune hypercoagulable disorder that has been shown to cause a large number of cardiac and neurological manifestations. Two recent studies have demonstrated abnormalities in cardiovascular autonomic function testing in APS patients without other cardiovascular or autoimmune disease. However, an association between autonomic disorders such as postural tachycardia syndrome and APS has not previously been described. Data were obtained by retrospective chart review. We identified 15 patients who have been diagnosed with APS and an autonomic disorder. The median age of the patients at the time of data analysis was 39 years. The autonomic disorders seen in these patients included postural tachycardia syndrome, neurocardiogenic syncope and orthostatic hypotension. The majority of patients (14/15) were female and the majority (14/15) had non-thrombotic neurological manifestations of APS, most commonly migraine, memory loss and balance disorder. Many also had livedo reticularis (11/15) and Raynaud's phenomenon (nine of 15). In some patients, the autonomic manifestations improved with anticoagulation and/or anti-platelet therapy; in others they did not. Two patients with postural tachycardia syndrome who failed to improve with the usual treatment of APS have been treated with intravenous immunoglobulin with significant improvement in their autonomic symptoms. We believe that autonomic disorders in APS may represent an important clinical association with significant implications for treatment. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Tank 241-AP-104 tank characterization plan

    International Nuclear Information System (INIS)

    Homi, C.S.

    1995-11-01

    This document is a plan that identifies the information needed to address relevant issues concerning short-term and long-term safe storage and long-term management of Double-Shell Tank (DST) 241-AP-104

  19. Protecting the lower extremity against a/p blast mines

    CSIR Research Space (South Africa)

    van Dyk, T

    2006-09-01

    Full Text Available the Lower Extremity against a/p Blast Mines J T van Dyk DEFENCE, PEACE, SAFETY AND SECURITY LANDWARDS SCIENCES COMPETENCY AREA Slide 2 © CSIR 2006 www.csir.co.za Contents • R&D overview • Effect of a/p blast mines • Basic... explosive principles – Shock effect (brisance) – Blast effect • Test methods • Protection concepts • Test results Slide 3 © CSIR 2006 www.csir.co.za Goals: Compare LEAP study results with field injuries Investigate energy...

  20. Using a Classroom Response System to Improve Multiple-Choice Performance in AP[R] Physics

    Science.gov (United States)

    Bertrand, Peggy

    2009-01-01

    Participation in rigorous high school courses such as Advanced Placement (AP[R]) Physics increases the likelihood of college success, especially for students who are traditionally underserved. Tackling difficult multiple-choice exams should be part of any AP program because well-constructed multiple-choice questions, such as those on AP exams and…

  1. Role of the AP-5 adaptor protein complex in late endosome-to-Golgi retrieval.

    Directory of Open Access Journals (Sweden)

    Jennifer Hirst

    2018-01-01

    Full Text Available The AP-5 adaptor protein complex is presumed to function in membrane traffic, but so far nothing is known about its pathway or its cargo. We have used CRISPR-Cas9 to knock out the AP-5 ζ subunit gene, AP5Z1, in HeLa cells, and then analysed the phenotype by subcellular fractionation profiling and quantitative mass spectrometry. The retromer complex had an altered steady-state distribution in the knockout cells, and several Golgi proteins, including GOLIM4 and GOLM1, were depleted from vesicle-enriched fractions. Immunolocalisation showed that loss of AP-5 led to impaired retrieval of the cation-independent mannose 6-phosphate receptor (CIMPR, GOLIM4, and GOLM1 from endosomes back to the Golgi region. Knocking down the retromer complex exacerbated this phenotype. Both the CIMPR and sortilin interacted with the AP-5-associated protein SPG15 in pull-down assays, and we propose that sortilin may act as a link between Golgi proteins and the AP-5/SPG11/SPG15 complex. Together, our findings suggest that AP-5 functions in a novel sorting step out of late endosomes, acting as a backup pathway for retromer. This provides a mechanistic explanation for why mutations in AP-5/SPG11/SPG15 cause cells to accumulate aberrant endolysosomes, and highlights the role of endosome/lysosome dysfunction in the pathology of hereditary spastic paraplegia and other neurodegenerative disorders.

  2. Comparison of a CCD and an APS for soft X-ray diffraction

    International Nuclear Information System (INIS)

    Stewart, Graeme; Bates, R; Blue, A; Maneuski, D; Clark, A; Turchetta, R; Dhesi, S S; Marchal, J; Steadman, P; Tartoni, N

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  3. Comparison of a CCD and an APS for soft X-ray diffraction

    Science.gov (United States)

    Stewart, Graeme; Bates, R.; Blue, A.; Clark, A.; Dhesi, S. S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-12-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  4. Synaptic and genomic responses to JNK and AP-1 signaling in Drosophila neurons

    Directory of Open Access Journals (Sweden)

    Bohmann Dirk

    2005-06-01

    Full Text Available Abstract Background The transcription factor AP-1 positively controls synaptic plasticity at the Drosophila neuromuscular junction. Although in motor neurons, JNK has been shown to activate AP-1, a positive regulator of growth and strength at the larval NMJ, the consequences of JNK activation are poorly studied. In addition, the downstream transcriptional targets of JNK and AP-1 signaling in the Drosophila nervous system have yet to be identified. Here, we further investigated the role of JNK signaling at this model synapse employing an activated form of JNK-kinase; and using Serial Analysis of Gene Expression and oligonucleotide microarrays, searched for candidate early targets of JNK or AP-1 dependent transcription in neurons. Results Temporally-controlled JNK induction in postembryonic motor neurons triggers synaptic growth at the NMJ indicating a role in developmental plasticity rather than synaptogenesis. An unexpected observation that JNK activation also causes a reduction in transmitter release is inconsistent with JNK functioning solely through AP-1 and suggests an additional, yet-unidentified pathway for JNK signaling in motor neurons. SAGE profiling of mRNA expression helps define the neural transcriptome in Drosophila. Though many putative AP-1 and JNK target genes arose from the genomic screens, few were confirmed in subsequent validation experiments. One potentially important neuronal AP-1 target discovered, CG6044, was previously implicated in olfactory associative memory. In addition, 5 mRNAs regulated by RU486, a steroid used to trigger conditional gene expression were identified. Conclusion This study demonstrates a novel role for JNK signaling at the larval neuromuscular junction and provides a quantitative profile of gene transcription in Drosophila neurons. While identifying potential JNK/AP-1 targets it reveals the limitations of genome-wide analyses using complex tissues like the whole brain.

  5. Structural modeling and molecular simulation analysis of HvAP2/EREBP from barley.

    Science.gov (United States)

    Pandey, Bharati; Sharma, Pradeep; Tyagi, Chetna; Goyal, Sukriti; Grover, Abhinav; Sharma, Indu

    2016-06-01

    AP2/ERF transcription factors play a critical role in plant development and stress adaptation. This study reports the three-dimensional ab initio-based model of AP2/EREBP protein of barley and its interaction with DNA. Full-length coding sequence of HvAP2/EREBP gene isolated from two Indian barley cultivars, RD 2503 and RD 31, was used to model the protein. Of five protein models obtained, the one with lowest C-score was chosen for further analysis. The N- and C-terminal regions of HvAP2 protein were found to be highly disordered. The dynamic properties of AP2/EREBP and its interaction with DNA were investigated by molecular dynamics simulation. Analysis of trajectories from simulation yielded the equilibrated conformation between 2-10ns for protein and 7-15ns for protein-DNA complex. We established relationship between DNA having GCC box and DNA-binding domain of HvAP2/EREBP was established by modeling 11-base-pair-long nucleotide sequence and HvAP2/EREBP protein using ab initio method. Analysis of protein-DNA interaction showed that a β-sheet motif constituting amino acid residues THR105, ARG100, ARG93, and ARG83 seems to play important role in stabilizing the complex as they form strong hydrogen bond interactions with the DNA motif. Taken together, this study provides first-hand comprehensive information detailing structural conformation and interactions of HvAP2/EREBP proteins in barley. The study intensifies the role of computational approaches for preliminary examination of unknown proteins in the absence of experimental information. It also provides molecular insight into protein-DNA binding for understanding and enhancing abiotic stress resistance for improving the water use efficiency in crop plants.

  6. Optimizing TCP Performance in Multi-AP Residential Broadband Connections via Minislot Access

    Directory of Open Access Journals (Sweden)

    Domenico Giustiniano

    2013-01-01

    Full Text Available The high bandwidth demand of Internet applications has recently driven the need of increasing the residential download speed. A practical solution to the problem is to aggregate the bandwidth of 802.11 access points (APs backhauls in range. Since 802.11 devices are usually single radio, the communication to APs on different radio channels requires a time-division multiple access (TDMA policy at the client station. With an in-depth experimental analysis and a customized 802.11 driver, in this paper, we show that the usage of multi-AP TDMA policy may cause degradation of the TCP throughput and an underutilization of the AP backhauls. We then introduce a simple analytical model that accurately predicts the TCP round-trip time (RTT with a multi-AP TDMA policy and propose a resource allocation algorithm to reduce the observed TCP RTT with a very low computational cost. Our proposed scheme runs locally at the client station and improves the aggregate throughput up to 1.5 times compared to state-of-the-art allocations. We finally show that the throughput achieved by our algorithm is very close to the theoretical upper bound in key simulation scenarios.

  7. Streams and magnetic fields in surface layers of Ap-stars

    International Nuclear Information System (INIS)

    Dolginov, A.Z.; Urpin, V.A.

    1978-01-01

    Magnetic field generation of Ap-stars is considered. It is shown that in the surface layers of Ap-stars inhomogeneity of chemical composition produces a strong magnetic field. Velocities of possible circulation of stellar matter are estimated. It is shown that circulation does not prevent the process of the magnetic field generation. It needs the order of million years, for arranging the stationary magnetic field in surface layers

  8. Control parameter optimization for AP1000 reactor using Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Wang, Pengfei; Wan, Jiashuang; Luo, Run; Zhao, Fuyu; Wei, Xinyu

    2016-01-01

    Highlights: • The PSO algorithm is applied for control parameter optimization of AP1000 reactor. • Key parameters of the MSHIM control system are optimized. • Optimization results are evaluated though simulations and quantitative analysis. - Abstract: The advanced mechanical shim (MSHIM) core control strategy is implemented in the AP1000 reactor for core reactivity and axial power distribution control simultaneously. The MSHIM core control system can provide superior reactor control capabilities via automatic rod control only. This enables the AP1000 to perform power change operations automatically without the soluble boron concentration adjustments. In this paper, the Particle Swarm Optimization (PSO) algorithm has been applied for the parameter optimization of the MSHIM control system to acquire better reactor control performance for AP1000. System requirements such as power control performance, control bank movement and AO control constraints are reflected in the objective function. Dynamic simulations are performed based on an AP1000 reactor simulation platform in each iteration of the optimization process to calculate the fitness values of particles in the swarm. The simulation platform is developed in Matlab/Simulink environment with implementation of a nodal core model and the MSHIM control strategy. Based on the simulation platform, the typical 10% step load decrease transient from 100% to 90% full power is simulated and the objective function used for control parameter tuning is directly incorporated in the simulation results. With successful implementation of the PSO algorithm in the control parameter optimization of AP1000 reactor, four key parameters of the MSHIM control system are optimized. It has been demonstrated by the calculation results that the optimized MSHIM control system parameters can improve the reactor power control capability and reduce the control rod movement without compromising AO control. Therefore, the PSO based optimization

  9. Fellow's Apéro

    CERN Multimedia

    Staff Association

    2017-01-01

    Let's get together, meet each other, exchange experiences and ideas, and share useful information on CERN and the Staff Association. Join us for Fellow's Apéro, organised by the Staff Association on Tuesday 21 February at 16.30 in Restaurant 1. There will be drinks and snacks for everybody! We look forward to seeing you there! Please confirm your participation on Doodle http://doodle.com/poll/skvm7ucm2z78i6bt or alternatively on Facebook https://www.facebook.com/events/1862757017340069/. Your delegates in the Staff Association, Barbora & Jiri

  10. AfAP2-1, An Age-Dependent Gene of Aechmea fasciata, Responds to Exogenous Ethylene Treatment

    Directory of Open Access Journals (Sweden)

    Ming Lei

    2016-02-01

    Full Text Available The Bromeliaceae family is one of the most morphologically diverse families with a pantropical distribution. To schedule an appropriate flowering time for bromeliads, ethylene is commonly used to initiate flower development in adult plants. However, the mechanism by which ethylene induces flowering in adult bromeliads remains unknown. Here, we identified an APETALA2 (AP2-like gene, AfAP2-1, in Aechmea fasciata. AfAP2-1 contains two AP2 domains and is a nuclear-localized protein. It functions as a transcriptional activator, and the activation domain is located in the C-terminal region. The expression level of AfAP2-1 is higher in juvenile plants than in adult plants, and the AfAP2-1 transcript level was rapidly and transiently reduced in plants treated with exogenous ethylene. Overexpression of AfAP2-1 in Arabidopsis thaliana results in an extremely delayed flowering phenotype. These results suggested that AfAP2-1 responds to ethylene and is a putative age-dependent flowering regulator in A. fasciata.

  11. Aviation Safety Program: Weather Accident Prevention (WxAP) Development of WxAP System Architecture And Concepts of Operation

    Science.gov (United States)

    Grantier, David

    2003-01-01

    This paper presents viewgraphs on the development of the Weather Accident Prevention (WxAP) System architecture and Concept of Operation (CONOPS) activities. The topics include: 1) Background Information on System Architecture/CONOPS Activity; 2) Activity Work in Progress; and 3) Anticipated By-Products.

  12. Osiguravanje međuoperabilnosti za Internet stvari: iskustvo s testiranjem CoAP protokola

    OpenAIRE

    Chen, Nanxing; Viho, César; Baire, Anthony; Huang, Xiaohong; Zha, Jiexi

    2014-01-01

    Constrained Application Protocol (CoAP) is a specialized web transfer protocol, designed for realizing interoperation with constrained networks and nodes for machine to machine applications like smart energy, building automation, etc. As an important ubiquitous application protocol for the future Internet of Things, CoAP will be potentially implemented by a wide range of smart devices to achieve cooperative services. Therefore, a high level of interoperability of CoAP implementations is cruci...

  13. AP-1 Oligodeoxynucleotides Reduce Aortic Elastolysis in a Murine Model of Marfan Syndrome.

    Science.gov (United States)

    Arif, Rawa; Zaradzki, Marcin; Remes, Anca; Seppelt, Philipp; Kunze, Reiner; Schröder, Hannes; Schwill, Simon; Ensminger, Stephan M; Robinson, Peter N; Karck, Matthias; Müller, Oliver J; Hecker, Markus; Wagner, Andreas H; Kallenbach, Klaus

    2017-12-15

    Marfan syndrome is characterized by high expression of matrix metalloproteinases (MMPs) in aortic smooth muscle cells (AoSMCs) associated with medial elastolysis and aortic root aneurysm. We aimed to reduce aortic elastolysis through decrease of MMP expression with decoy oligodeoxynucleotides (dODNs) neutralizing the transcription factor activating factor-1 (AP-1). AP-1 abundance in nuclear extracts as well as MMP-2 and MMP-9 expression were significantly increased in isolated mAoSMC of mgR/mgR Marfan mice compared to wild-type cells. Exposure to AP-1 neutralizing dODNs resulted in a significant reduction of basal and interleukin-1β-stimulated MMP expression and activity in mAoSMCs. Moreover, increased migration and formation of superoxide radical anions was substantially decreased in mAoSMCs by AP-1 dODN treatment. Aortic grafts from donor Marfan mice were treated with AP-1- dODN ex vivo and implanted as infrarenal aortic interposition grafts in mgR/mgR mice. Pretreatment of aortic grafts with AP-1 dODN led to reduced elastolysis, macrophage infiltration, and MMP activity. Permeability of the endothelial monolayer was increased for dODN in mgR/mgR aortae with observed loss of tight junction proteins ZO-1 and occludin, enabling dODN to reach the tunica media. Targeting AP-1 activity offers a new potential strategy to treat the vascular phenotype associated with Marfan syndrome. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  14. Normal mediastinal lymph node size and shape; CT and cadaver study

    International Nuclear Information System (INIS)

    Im, Chung Kie; Lee, Kyung Soo; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    With the view point of size, shape and arrangement pattern, authors present normal mediastinal lymph node from the analysis of 61 cases of CT scan and multidirectional section of 2 cadavers. The result were as follows: 1. Transverse diameter of the lymph nodes, demonstrated in cadaver section, was 3 to 6mm in upper paratracheal area and 5 to 14mm in juxta-carinal and AP-window area. Arrangement of the lymph nodes showed tendency of longitudinal direction in lower paratracheal, and juxtacarinal area, while that of AP window showed tendency of AP direction as long axis. 2. Mean and the largest size of the lymph nodes demonstrated in CT scan were 3.7mm, 8mm in upper paratracheal area, and 6mm, 12mm in lower paratracheal area, and 7.1mm, 14mm in juxtacarinal area, and 6.3mm and 11mm in aorticopulmonary window area. 3. Size of the lymph nodes in CT scan showed linear increasing tendency according to increasing age (y=0.32, p<0.005). 4. Shape of the lymph nodes in CT scan were mostly round in upper paratracheal area while that of aorticopulmonary window showed higher incidence of oval and elongated shape. 5. Recommended size criterior of abnormal lymph node is 10mm in upper paratracheal area and 15mm in the other area

  15. Airborne Precision Spacing (APS) Dependent Parallel Arrivals (DPA)

    Science.gov (United States)

    Smith, Colin L.

    2012-01-01

    The Airborne Precision Spacing (APS) team at the NASA Langley Research Center (LaRC) has been developing a concept of operations to extend the current APS concept to support dependent approaches to parallel or converging runways along with the required pilot and controller procedures and pilot interfaces. A staggered operations capability for the Airborne Spacing for Terminal Arrival Routes (ASTAR) tool was developed and designated as ASTAR10. ASTAR10 has reached a sufficient level of maturity to be validated and tested through a fast-time simulation. The purpose of the experiment was to identify and resolve any remaining issues in the ASTAR10 algorithm, as well as put the concept of operations through a practical test.

  16. Karakterisasi ekstrak kasar fitase termofilik dari bakteri kawah Ijen Banyuwangi, isolat AP-17

    Directory of Open Access Journals (Sweden)

    Aline Puspita Kusumadjaja

    2010-12-01

    Full Text Available Crude thermophilic phytase was produced by isolate AP-17 that has been isolated from Ijen Crater Banyuwangi. Based on Gram test, isolate AP-17 was gram positive spore forming rod shape bacteria so that it was identified as Bacillus sp. AP-17. Crude thermophilic phytase isolated from Bacillus sp. AP-17 had the optimum temperature at 75 ° C with activity of 0.1413 U/ml, and its optimum pH was at pH 6 with activity of 0.0875 U/ml. The enzyme was stable when heated at 75 ° C for three hours and still had 90% activity when it was exposed at pH 5 €“8, optimum temperature, for one hour.

  17. Thermophysical properties of 36% and 100% TiAP solvents at 298.15 K

    International Nuclear Information System (INIS)

    Shekhar Kumar; Biplab Das; Mondal, P.

    2011-01-01

    Thermophysical properties of alternate PUREX/UREX extractant tri-iso-amyl phosphate (TiAP) in different diluents are not available in literature. In this study, density, viscosity and refractive indices of 36% v/v TiAP solutions (∼1.1 M) in C 6 -C 16 n-alkanes, benzene, toluene, carbon tetrachloride and iso-octane at 298.15 K and 0.1 MPa have been measured experimentally. In the case of n-alkanes, these properties were correlated by empirical functions of carbon number of diluents. In addition, for 36% TiAP and 100% TiAP solutions, nitric acid extraction studies were also performed and acid uptakes as well as thermophysical properties of equilibrated phases were also measured. Compositions of solvates in equilibrated organic phases were also proposed. (author)

  18. Increasing the reliability, availability, and maintainability of the AP600 by design

    International Nuclear Information System (INIS)

    Trombola, D.; Meyer, C.

    1993-01-01

    The AP600 design is based on providing a safe, simple, standardized, and economically competitive design with a high degree of operability and ease of maintenance. Design features such as component selection, layout, and standardization increase the probability that targeted repair times are achieved. Design requirements from the utility industry and industry design practices have established criteria for: layout, changeout and replacement of parts and components; access for major pieces of equipment; and vehicle passage. These features coupled with a solid reliability assurance and maintenance program will help the AP600 meet its objectives for operation and maintenance. The AP600 draws on the operating experience and lessons learned from the utility community through design workshops and design review interaction, as well as operating plant data from sources several sources. Internally, the AP600 program incorporates the resources of Westinghouse NSD (Nuclear Service Division), which for decades has provided refueling, steam generator, reactor coolant pump, and other operating plant services. Since the early phases of the design process, the AP600 Program has executed a comprehensive reliability, availability, and maintainability program (RAM) which dealt primarily with assessing and improving plant availability. In conjunction with this program a Probabilistic Risk Assessment (PRA) was performed and submitted to the NRC with the Standard Safety Analysis Report (SSAR) in June 1992. This paper describes how AP600 ensures that the plant has design features to enhance reliability, availability, and maintainability. The RAM program that brings the plant through the design certification phase is described

  19. Clinical significance of detection of plasma β-amyloid protein (β-AP) levels in patients with senile dementia

    International Nuclear Information System (INIS)

    Yu Binwei; Xu Shangao; Lu Zhifeng; Wang Weihua; Mao Xiaohua; Zhou Chaohua

    2007-01-01

    Objective: To explore the value of determination of plasma β-AP levels in the diagnosis and monitoring of Alzheimer's disease (AD). Methods: Plasma β-AP levels were weasured with RIA in 43 patients with AD and 58 controls, as well as in 8 AD patients after a course of cerebrolysin treatment. Results: The plasma β-AP levels in the AD patients were significance higher those in controls (P<0.01). The plasma β-AP levels were especially higher in the severe eases, however, the plasma β-AP levels in some late AD patients dropped again, even lower than those in the controls. The plasma β-AP levels in the 8 AD patients decreased significantly after treatment with cerebrolysin. Conclusion: The plasma β-AP is a biochemical maker of AD. Dynamic examnation of plasma β-AP levels is valuable in assessing the progression and prognosis of the disease. (authors)

  20. Standardized safety management of AP1000 nuclear power plant

    International Nuclear Information System (INIS)

    Li Xingwen; Cao Zhiqiang; Cong Jiuyuan

    2011-01-01

    In 2002, China published and implemented the Law of the People's Republic of China on Work Safety and promulgated a series of guidelines and policies, which strengthened the safety management supervision. Standardization of safety, as another important step on safety supervision, comes after safety assesment and safety production licensing system, is also a permanent solution. Standardization of safety is a strategic, long term and fundamental work, which is also the basic access to achieving scientific safety management and increasing the inherent safety of an enterprise. Haiyang AP1000 nuclear power plant, adopting the modularized, 'open-top' and parallel construction means, overturned the traditional construction theory of installation work comes after the civil work and greatly shorten the construction period. At the same time, the notable increase of oversize module transportation and lifting and parallel construction raises higher demands for safety management. This article combines the characteristics and difficulties of safety management for Haiyang AP1000 nuclear power plant, puts forward ideas and methods for standardized safety management, and could also serve as reference to the safety management for other AP1000 projects. (authors)

  1. Assistant Practitioners (APs) in radiography: An exploration of perceptions and experiences related to role development

    International Nuclear Information System (INIS)

    Stewart-Lord, Adéle; Ballinger, Claire; McLaren, Susan M.

    2014-01-01

    A mixed methods study was undertaken to investigate the role of Assistant Practitioners (APs) in radiography from an AP perspective and to explore how their roles have been integrated into the radiography workforce across England. The quantitative survey was followed by a qualitative study utilising semi-structured interviews, findings of which are presented in this paper. Thirty eight face to face, semi-structured interviews were conducted. Thematic analysis allowed the researcher to report experiences and meanings for APs, through a process of identifying, analysis and reporting patterns. Three main themes and eight sub-themes emerged from the data analyses. The first theme showed how participants felt the AP role developed over time. AP practice revealed a range of roles and responsibilities which resulted in confusing boundaries. Participants felt uncertain about their future role as APs. The second theme reflected on the factors that influenced the participants' perceptions. Findings showed that the acceptance of APs changed over time. Participants believed that they were competent to perform their roles and responsibilities. The third and final theme focused on the facilitating and constraining factors in AP practice. Supervision was seen as a constraining internal factor highlighting the fact that supervision practices varied across departments. In conclusion findings have identified a need for revised supervisory standards to inform departmental protocols and procedures

  2. Characteristics and application study of AP1000 NPPs equipment reliability classification method

    International Nuclear Information System (INIS)

    Guan Gao

    2013-01-01

    AP1000 nuclear power plant applies an integrated approach to establish equipment reliability classification, which includes probabilistic risk assessment technique, maintenance rule administrative, power production reliability classification and functional equipment group bounding method, and eventually classify equipment reliability into 4 levels. This classification process and result are very different from classical RCM and streamlined RCM. It studied the characteristic of AP1000 equipment reliability classification approach, considered that equipment reliability classification should effectively support maintenance strategy development and work process control, recommended to use a combined RCM method to establish the future equipment reliability program of AP1000 nuclear power plants. (authors)

  3. Complicated spastic paraplegia in patients with AP5Z1 mutations (SPG48)

    Science.gov (United States)

    Hirst, Jennifer; Madeo, Marianna; Smets, Katrien; Edgar, James R.; Schols, Ludger; Li, Jun; Yarrow, Anna; Deconinck, Tine; Baets, Jonathan; Van Aken, Elisabeth; De Bleecker, Jan; Datiles, Manuel B.; Roda, Ricardo H.; Liepert, Joachim; Züchner, Stephan; Mariotti, Caterina; De Jonghe, Peter; Blackstone, Craig

    2016-01-01

    Objective: Biallelic mutations in the AP5Z1 gene encoding the AP-5 ζ subunit have been described in a small number of patients with hereditary spastic paraplegia (HSP) (SPG48); we sought to define genotype–phenotype correlations in patients with homozygous or compound heterozygous sequence variants predicted to be deleterious. Methods: We performed clinical, radiologic, and pathologic studies in 6 patients with biallelic mutations in AP5Z1. Results: In 4 of the 6 patients, there was complete loss of AP-5 ζ protein. Clinical features encompassed not only prominent spastic paraparesis but also sensory and motor neuropathy, ataxia, dystonia, myoclonus, and parkinsonism. Skin fibroblasts from affected patients tested positive for periodic acid Schiff and autofluorescent storage material, while electron microscopic analysis demonstrated lamellar storage material consistent with abnormal storage of lysosomal material. Conclusions: Our findings expand the spectrum of AP5Z1-associated neurodegenerative disorders and point to clinical and pathophysiologic overlap between autosomal recessive forms of HSP and lysosomal storage disorders. PMID:27606357

  4. HIV-1 Nef hijacks clathrin coats by stabilizing AP-1:Arf1 polygons.

    Science.gov (United States)

    Shen, Qing-Tao; Ren, Xuefeng; Zhang, Rui; Lee, Il-Hyung; Hurley, James H

    2015-10-23

    The lentiviruses HIV and simian immunodeficiency virus (SIV) subvert intracellular membrane traffic as part of their replication cycle. The lentiviral Nef protein helps viruses evade innate and adaptive immune defenses by hijacking the adaptor protein 1 (AP-1) and AP-2 clathrin adaptors. We found that HIV-1 Nef and the guanosine triphosphatase Arf1 induced trimerization and activation of AP-1. Here we report the cryo-electron microscopy structures of the Nef- and Arf1-bound AP-1 trimer in the active and inactive states. A central nucleus of three Arf1 molecules organizes the trimers. We combined the open trimer with a known dimer structure and thus predicted a hexagonal assembly with inner and outer faces that bind the membranes and clathrin, respectively. Hexagons were directly visualized and the model validated by reconstituting clathrin cage assembly. Arf1 and Nef thus play interconnected roles in allosteric activation, cargo recruitment, and coat assembly, revealing an unexpectedly intricate organization of the inner AP-1 layer of the clathrin coat. Copyright © 2015, American Association for the Advancement of Science.

  5. AP-2α Inhibits c-MYC Induced Oxidative Stress and Apoptosis in HaCaT Human Keratinocytes

    Directory of Open Access Journals (Sweden)

    Lei Yu

    2009-01-01

    AP-2 may have a direct effect on the c-myc gene. Chromatin immunoprecipitation assays demonstrated that AP-2 proteins bound to a cluster of AP-2 binding sites located within a 2 kb upstream regulatory region of c-myc These results suggest that the negative regulation of AP-2 on c-MYC activity was achieved through binding of AP-2 protein to the c-myc gene. The effects of AP-2 on c-MYC induced ROS accumulation and apoptosis in epidermal keratinocytes are likely to play an important role in cell growth, differentiation and carcinogenesis of the skin.

  6. Foundations for College and Beyond: Looking Back on AP Art History

    Science.gov (United States)

    Schoenbohm, Laurel

    2013-01-01

    It was years after this author's AP Art History course in high school, and two years after college. She and some friends decided to fill a day during the Thanksgiving visits appreciating fine art. Prior to that AP course her senior year of high school, touring an art museum had seemed like the equivalent of going to the dentist. But after…

  7. Improvements in nuclear plant staffing resulting from the AP600 design programme

    International Nuclear Information System (INIS)

    Mycoff, C.

    2001-01-01

    The staffing for a single-unit AP600 is estimated to require a staff for operation and maintenance about 32% smaller than current generation power plants of similar size. These staffing reductions are driven primarily by various features incorporated into the AP600 plant design. (author)

  8. Temporal pattern of AP-1 DNA-binding activity in the rat hippocampus following a kindled seizure

    Energy Technology Data Exchange (ETDEWEB)

    Shomori, T. [Department of Neurology, Okayama University Medical School, 2-5-1, Shikata-cho Okayama (Japan); Hayabara, T. [Clinical Research Institute, National Sanatorium Minamiokayama Hospital, 4066 Hayashima-cho (Japan); Ishihara, T. [Department of Neuropsychiatry, Okayama University Medical School, 2-5-1 Shikata-cho Okayama (Japan); Okada, S. [Department of Neurology, Okayama University Medical School, 2-5-1, Shikata-cho Okayama (Japan); Akiyama, K. [Department of Neuropsychiatry, Okayama University Medical School, 2-5-1 Shikata-cho Okayama (Japan); Sato, K. [Clinical Research Institute, National Sanatorium Minamiokayama Hospital, 4066 Hayashima-cho (Japan); Kashihara, K. [Department of Neurology, Okayama University Medical School, 2-5-1, Shikata-cho Okayama (Japan)

    1997-07-28

    DNA binding by transcripton factor AP-1 was enhanced remarkably following kindling stimulation in rat amygdala. Maximum increase occurred 2 h after stimulation with return to baseline within 24 h. Supershift and western analyses revealed that 38,000 mol. wt Fos-related antigen and JunD were the main components of the evoked AP-1 complexes at the time their induction reached maximum. AP-1 induction 2 h after the last kindling stimulation was more prominent in samples from previously kindled rats than in those from non-kindled rats. This study sought to establish the role of AP-1 in plastic changes of the hippocampus associated with kindling. Male Sprague-Dawley rats were kindled from the left amygdala until they exhibited Racine [15] class 5 generalized seizures. Nuclear proteins were extracted from dorsal hippocampi obtained from 0 to 24 h after final stimulations. From these, we evaluated the temporal pattern of DNA binding by AP-1 using a gel mobility-shift assay with a {sup 32}P-labelled AP-1 probe. Supershift and western analyses were added to investigate components of the seizure-evoked AP-1 complexes. Our results suggest that the basal level of AP-1 complexes is not associated with the seizure susceptibility in kindling. However, development of kindling appears to facilitate stimulus-evoked AP-1 induction, probably via plastic changes in the central nervous system. AP-1 may mediate such changes by regulating expression of certain genes. (Copyright (c) 1997 Elsevier Science B.V., Amsterdam. All rights reserved.)

  9. Visualizing Electron Beam Dynamics and Instabilities with Synchrotron Radiation at the APS

    CERN Document Server

    Yang Bing Xin

    2005-01-01

    The Advanced Photon Source (APS) is a third generation hard x-ray source serving a large user community. In order to characterize the high-brilliance beams, the APS diagnostics beamlines have been developed into a full photon diagnostics suite. We will describe the design and capabilities of the APS visible light imaging line, the bend magnet x-ray pinhole camera, and a unique diagnostics undulator beamline. Their primary functions are to support the APS user operations by providing information on beam sizes (20 - 100 micrometers), divergence (3 – 25 microradians), and bunch length (20 – 50 ps). Through the use of examples, we will show how these complementary imaging tools are used to visualize the electron dynamics and investigate beam instabilities. Special emphasis will be put on the use of undulator radiation, which is uniquely suitable for time-resolved imaging of electron beam with high spatial resolution, and for measurements of longitudinal beam properties such as beam energy spread...

  10. Charges collection induced in APS by heavy particles: influence of design parameters

    International Nuclear Information System (INIS)

    Belredon, Xavier

    2003-01-01

    We have studied the design parameters influence on heavy ions-induced charge collection physics in APS. The goal is to determine the key parameters for an optimised space environment 'particle detector' APS design. It appears that diffusion is the dominant charge collection mechanism in all the studied technology types, with a smaller magnitude in case of epitaxial technologies. Following proton irradiation, a delayed charge collection and loss of collected charges have been observed. These phenomena are explained by the combination of carriers diffusion and action of the traps generated in the device. Even if they cannot be avoid in space applications, these effects are reduced in case of epitaxial technologies. This work led to the design parameters definition of an optimized APS 'particle detector' and to its fabrication. The results obtained on this APS confirm the previous conclusions and let us define the detection range of such detectors from 0.03 to 50 MeV.cm 2 .mg -1 . (author) [fr

  11. Knockdown of CDK2AP1 in human embryonic stem cells reduces the threshold of differentiation.

    Directory of Open Access Journals (Sweden)

    Khaled N Alsayegh

    Full Text Available Recent studies have suggested a role for the Cyclin Dependent Kinase-2 Associated Protein 1 (CDK2AP1 in stem cell differentiation and self-renewal. In studies with mouse embryonic stem cells (mESCs derived from generated mice embryos with targeted deletion of the Cdk2ap1 gene, CDK2AP1 was shown to be required for epigenetic silencing of Oct4 during differentiation, with deletion resulting in persistent self-renewal and reduced differentiation potential. Differentiation capacity was restored in these cells following the introduction of a non-phosphorylatible form of the retinoblastoma protein (pRb or exogenous Cdk2ap1. In this study, we investigated the role of CDK2AP1 in human embryonic stem cells (hESCs. Using a shRNA to reduce its expression in hESCs, we found that CDK2AP1 knockdown resulted in a significant reduction in the expression of the pluripotency genes, OCT4 and NANOG. We also found that CDK2AP1 knockdown increased the number of embryoid bodies (EBs formed when differentiation was induced. In addition, the generated EBs had significantly higher expression of markers of all three germ layers, indicating that CDK2AP1 knockdown enhanced differentiation. CDK2AP1 knockdown also resulted in reduced proliferation and reduced the percentage of cells in the S phase and increased cells in the G2/M phase of the cell cycle. Further investigation revealed that a higher level of p53 protein was present in the CDK2AP1 knockdown hESCs. In hESCs in which p53 and CDK2AP1 were simultaneously downregulated, OCT4 and NANOG expression was not affected and percentage of cells in the S phase of the cell cycle was not reduced. Taken together, our results indicate that the knockdown of CDK2AP1 in hESCs results in increased p53 and enhances differentiation and favors it over a self-renewal fate.

  12. Influence of performance improvement of AP1000 nuclear island main equipment forging on manufacturing

    International Nuclear Information System (INIS)

    Liu Zhiying

    2013-01-01

    In order to comply with the 60-year design life of an AP1000 nuclear power station, higher strength and ductility requirements have been made on AP1000 nuclear island SG forgings than on CPR1000 nuclear island main equipment. In addition, bigger size of AP1000 nuclear island SG forgings increases the difficulty of manufacturing them. Insufficient recognition of these changes may cause unstable quality of forgings and possible quality problems in follow-up welding procedure. On the basis of comparison and analysis of AP1000 nuclear island SG forgings and CPR1000 nuclear island forgings, this thesis suggests clear directions for the actions we need to take. (author)

  13. A second-generation superconducting undulator cryostat for the APS

    Science.gov (United States)

    Fuerst, J.; Hasse, Q.; Ivanyushenkov, Y.; Kasa, M.; Shiroyanagi, Y.

    2017-12-01

    A second-generation cryocooler-based cryostat has been designed and built to support a new helically wound superconducting undulator (SCU) magnet for the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The design represents an evolution of existing SCU cryostats currently in operation in the APS storage ring. Value engineering and lessons learned have resulted in a smaller, cheaper, and simpler cryostat design compatible with existing planar magnets as well as the new helically wound device. We describe heat load and quench response results, design and operational details, and the “build-to-spec” procurement strategy.

  14. Structuring the AP Art History Course

    Science.gov (United States)

    Herscher, Walter R.

    2013-01-01

    While AP (Advanced Placement) Art History may be taught within the art department in many schools, social studies teachers are equally capable of teaching the course well. They have the historical background to discuss the reasons for changes in art styles. A teacher's preparation is similar to teaching a course stressing political history,…

  15. The Promise of AP World History

    Science.gov (United States)

    Saldaña, Cristóbal T.

    2013-01-01

    AP World History is the ideal history course. It introduces students to 10,000 years of world history, and demands critical reading, critical writing, and critical thinking skills on the part of both the teacher and the students. It requires students to build their expertise in reading their textbook, and places demands on the teacher to assign…

  16. The study on neutron and photon distribution of AP1000 reactor by MCNP code

    International Nuclear Information System (INIS)

    Chen Defeng; Shen Mingqi

    2014-01-01

    The core and reactor structural of AP1000 was modeled by the MCNP calculation program which is based on the Monte Carlo method in this paper, the neutron and photon distribution of AP1000 reactor core was calculated by the conditions of reactor critical. The results show that the AP1000 reactor neutron and photon distribution is in accordance with the critical design of PWR. (authors)

  17. Real-time orbit feedback at the APS

    International Nuclear Information System (INIS)

    Carwardine, J.

    1998-01-01

    A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5 microm rms horizontally and 2 microm rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit motion

  18. Ectopic expression of Jatropha curcas APETALA1 (JcAP1 caused early flowering in Arabidopsis, but not in Jatropha

    Directory of Open Access Journals (Sweden)

    Mingyong Tang

    2016-04-01

    Full Text Available Jatropha curcas is a promising feedstock for biofuel production because Jatropha oil is highly suitable for the production of biodiesel and bio-jet fuels. However, Jatropha exhibits a low seed yield as a result of unreliable and poor flowering. APETALA1 (AP1 is a floral meristem and organ identity gene in higher plants. The flower meristem identity genes of Jatropha have not yet been identified or characterized. To better understand the genetic control of flowering in Jatropha, an AP1 homolog (JcAP1 was isolated from Jatropha. An amino acid sequence analysis of JcAP1 revealed a high similarity to the AP1 proteins of other perennial plants. JcAP1 was expressed in inflorescence buds, flower buds, sepals and petals. The highest expression level was observed during the early developmental stage of the flower buds. The overexpression of JcAP1 using the cauliflower mosaic virus (CaMV 35S promoter resulted in extremely early flowering and abnormal flowers in transgenic Arabidopsis plants. Several flowering genes downstream of AP1 were up-regulated in the JcAP1-overexpressing transgenic plant lines. Furthermore, JcAP1 overexpression rescued the phenotype caused by the Arabidopsis AP1 loss-of-function mutant ap1-11. Therefore, JcAP1 is an ortholog of AtAP1, which plays a similar role in the regulation of flowering in Arabidopsis. However, the overexpression of JcAP1 in Jatropha using the same promoter resulted in little variation in the flowering time and floral organs, indicating that JcAP1 may be insufficient to regulate flowering by itself in Jatropha. This study helps to elucidate the function of JcAP1 and contributes to the understanding of the molecular mechanisms of flower development in Jatropha.

  19. Ectopic expression of Jatropha curcas APETALA1 (JcAP1) caused early flowering in Arabidopsis, but not in Jatropha

    Science.gov (United States)

    Tang, Mingyong; Tao, Yan-Bin

    2016-01-01

    Jatropha curcas is a promising feedstock for biofuel production because Jatropha oil is highly suitable for the production of biodiesel and bio-jet fuels. However, Jatropha exhibits a low seed yield as a result of unreliable and poor flowering. APETALA1 (AP1) is a floral meristem and organ identity gene in higher plants. The flower meristem identity genes of Jatropha have not yet been identified or characterized. To better understand the genetic control of flowering in Jatropha, an AP1 homolog (JcAP1) was isolated from Jatropha. An amino acid sequence analysis of JcAP1 revealed a high similarity to the AP1 proteins of other perennial plants. JcAP1 was expressed in inflorescence buds, flower buds, sepals and petals. The highest expression level was observed during the early developmental stage of the flower buds. The overexpression of JcAP1 using the cauliflower mosaic virus (CaMV) 35S promoter resulted in extremely early flowering and abnormal flowers in transgenic Arabidopsis plants. Several flowering genes downstream of AP1 were up-regulated in the JcAP1-overexpressing transgenic plant lines. Furthermore, JcAP1 overexpression rescued the phenotype caused by the Arabidopsis AP1 loss-of-function mutant ap1-11. Therefore, JcAP1 is an ortholog of AtAP1, which plays a similar role in the regulation of flowering in Arabidopsis. However, the overexpression of JcAP1 in Jatropha using the same promoter resulted in little variation in the flowering time and floral organs, indicating that JcAP1 may be insufficient to regulate flowering by itself in Jatropha. This study helps to elucidate the function of JcAP1 and contributes to the understanding of the molecular mechanisms of flower development in Jatropha. PMID:27168978

  20. Evaluation of bone-seeking novel radiotracer {sup 68}Ga-NO2AP-Bisphosphonate for the detection of skeletal metastases in carcinoma breast

    Energy Technology Data Exchange (ETDEWEB)

    Passah, Averilicia; Tripathi, Madhavi; Ballal, Sanjana; Yadav, Madhav Prasad; Kumar, Rajeev; Chakraborty, Partha Sarathi; Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, Ansari Nagar, New Delhi (India); Roesch, Frank; Meckel, Marian [Johannes-Gutenberg-University, Nuclear Chemistry, Mainz (Germany)

    2017-01-15

    The successful labelling of bisphosphonates (BP) with {sup 68}Ga using macrocyclic chelators such as the based triazacyclononane (NO2AP) is a step forward in the in-house availability of a novel bone-seeking PET radiopharmaceutical with dual advantage of PET/CT imaging and generator production. In this study, we compared the novel generator-based skeletal radiotracer {sup 68}Ga-1,4,7-triazacyclonone-1,4-diacetic acid ({sup 68}Ga-NO2AP-BP) with sodium fluoride ({sup 18}F-NaF) for the detection of skeletal metastases in breast cancer patients. In addition, dosimetric analysis of {sup 68}Ga-NO2AP-BP was performed in a subset of patients. This was a prospective study of histopathologically proven cases of breast cancer patients who were referred for bone scintigraphy and underwent positron emission tomography/computed tomography (PET/CT) with {sup 18}F-NaF and {sup 68}Ga-NO2AP-BP within a week in random order. The scans of each patient were compared both qualitatively for image quality and quantitatively for number of lesions and SUVmax of lesions. Dosimetric analysis was performed in five patients. Their PET/CT scans were acquired at multiple time points and urine and blood samples were collected. Dosimetric calculations were performed using OLINDA/EXM 1.1 software. Statistical analysis was done using Stata 13 (StataCorp) software package. An agreement analysis regarding number of lesions detected with the two skeletal radiotracers was carried out. The image quality of {sup 68}Ga-NO2AP-BP PET/CT scans were comparable to that of {sup 18}F-NaF. There was no statistically significant difference in the SUVmax of lesions, normal bone and lesion to background ratio between the two skeletal radiotracers. There was good agreement in the number of lesions detected by both skeletal radiotracers. The mean whole body effective dose for {sup 68}Ga-NO2AP-BP was 0.00583 mSv/MBq and the effective dose equivalent was 0.0086 mSv/MBq. The excellent lesion detection agreement between

  1. Physical interaction between the strawberry allergen Fra a 1 and an associated partner FaAP: Interaction of Fra a 1 proteins and FaAP.

    Science.gov (United States)

    Franz-Oberdorf, Katrin; Langer, Andreas; Strasser, Ralf; Isono, Erika; Ranftl, Quirin L; Wunschel, Christian; Schwab, Wilfried

    2017-10-01

    The strawberry fruit allergens Fra a 1.01E, Fra a 1.02 and Fra a 1.03 belong to the group of pathogenesis-related 10 (PR-10) proteins and are homologs of the major birch pollen Bet v 1 and apple allergen Mal d 1. Bet v 1 related proteins are the most extensively studied allergens but their physiological function in planta remains elusive. Since Mal d 1-Associated Protein has been previously identified as interaction partner of Mal d 1 we studied the binding of the orthologous Fra a 1-Associated Protein (FaAP) to Fra a 1.01E/1.02/1.03. As the C-terminal sequence of FaAP showed strong auto-activation activity in yeast 2-hybrid analysis a novel time resolved DNA-switching system was successfully applied. Fra a 1.01E, Fra a 1.02, and Fra a 1.03 bind to FaAP with K D of 4.5 ± 1.1, 15 ± 3, and 11 ± 2 nM, respectively. Fra a 1.01E forms a dimer, whereas Fra a 1.02 and Fra a 1.03 bind as monomer. The results imply that PR-10 proteins might be integrated into a protein-interaction network and FaAP binding appears to be essential for the physiological function of the Fra a 1 proteins. © 2017 Wiley Periodicals, Inc.

  2. Analysis and characterization of double shell tank 241-AP-108

    International Nuclear Information System (INIS)

    Miller, G.L.

    1994-01-01

    This document is the first part of a three-part report describing the analysis and characterization of double shell tank 241-AP-108 which is located at the Hanford Reservation.This document is the analytical laboratory data package entitled 'Analysis and Characterization of Double Shell Tank 241-AP-108' which contains a case sampling history, the sampling protocols, the analytical procedures, sampling and analysis quality assurance and quality control measures, and chemical analysis results for samples obtained from the tank

  3. Study on the operation mode for indigenization and standardization of AP1000 technology

    International Nuclear Information System (INIS)

    Gao Zhihu; Cheng Huiping

    2014-01-01

    This paper describes the importance and necessity of developing standardized AP1000 technology, and analyzes the problems faced and measures to be taken. The operation mode, known as the Committee of AP1000 Standardized Design and Innovation Management, was first put forward in China. And the paper also discusses how to arouse the enthusiasm of the owners, designers, manufactures, as well as construction, installation, regulation and other parties, how to exploit the advantage of whole industry to promote the localization and standardization of AP1000 technology. (authors)

  4. N-Glycosylation instead of cholesterol mediates oligomerization and apical sorting of GPI-APs in FRT cells.

    Science.gov (United States)

    Imjeti, Naga Salaija; Lebreton, Stéphanie; Paladino, Simona; de la Fuente, Erwin; Gonzalez, Alfonso; Zurzolo, Chiara

    2011-12-01

    Sorting of glycosylphosphatidyl-inositol--anchored proteins (GPI-APs) in polarized epithelial cells is not fully understood. Oligomerization in the Golgi complex has emerged as the crucial event driving apical segregation of GPI-APs in two different kind of epithelial cells, Madin-Darby canine kidney (MDCK) and Fisher rat thyroid (FRT) cells, but whether the mechanism is conserved is unknown. In MDCK cells cholesterol promotes GPI-AP oligomerization, as well as apical sorting of GPI-APs. Here we show that FRT cells lack this cholesterol-driven oligomerization as apical sorting mechanism. In these cells both apical and basolateral GPI-APs display restricted diffusion in the Golgi likely due to a cholesterol-enriched membrane environment. It is striking that N-glycosylation is the critical event for oligomerization and apical sorting of GPI-APs in FRT cells but not in MDCK cells. Our data indicate that at least two mechanisms exist to determine oligomerization in the Golgi leading to apical sorting of GPI-APs. One depends on cholesterol, and the other depends on N-glycosylation and is insensitive to cholesterol addition or depletion.

  5. OLP embedment design method research for AP1000 nuclear plant

    International Nuclear Information System (INIS)

    Li Cheng; Li Shaoping; Liu Jianwei

    2013-01-01

    Background: One of the most advanced nuclear power technology, the first AP1000 reactor is under construction in China. Modularization is one of the main characteristics for AP1000 nuclear plant building. Module wall with steel face plate is used instead of reinforced concrete structure wall. A number of OLP embedments need to be installed into the module wall to connect other structures such as pipes, equipment, operation platforms and any other component attached to the module wall. Therefore, the design of embedment is very important in AP1000 structural design. Purpose: A finite element analysis method and tool for embedment design is needed for convenience. Methods: This paper applies the self-developed GTStrudl command template and VBA macro program for embedment capacity calculation and evaluation based on Microsoft Excel to the embedment design. Results: A Microsoft Excel template for embedment design is developed. Conclusions: The analysis method and template brings reasonable results and may provide some help and use for reference for the engineering practice. (authors)

  6. A study on normal value of eyeball protrusion in Korean adult using CT

    International Nuclear Information System (INIS)

    Song, Chi Sung; Chang, Kee Hyun

    1984-01-01

    CT may be valuably used in determination of proptosis. Normal value of eyeball protrusion was measured in normal Koreans using CT. Among 86 Koreans, 26 have normal both eyes, but 60 have one normal eye with one abnormal eye (chiefly, proptosis and and eyeball tumor). The results of 112 eyes are as follows: Absolute measurement of 'a', that is, the distance between cornea and IZL (interzygomatic line) is 16.0±3.4 mm in male (for 63 eye), 15.7±4.0 mm in female for 49 eyes. Ratio of 'a' over 'A' (A-P diameter of eyeball) is 57±12% is male (for 63 eye), 57±14% in female (for 49 eye) Discrepancy of eyeball protrusion between both eyes is 0.67±1.5 mm (for 26 adults). Practically, normal range of eyeball prtotrusion ('a') is 12.6 mm < male < 19.4 mm, 11.7 mm < female < 19.7 mm. 'a/A' ratio over 70% and over 2mm discrepancy between both eyes are also suggested as genuine exophthalmos

  7. Expression, purification, crystallization and structure of human adipocyte lipid-binding protein (aP2)

    International Nuclear Information System (INIS)

    Marr, Eric; Tardie, Mark; Carty, Maynard; Brown Phillips, Tracy; Wang, Ing-Kae; Soeller, Walt; Qiu, Xiayang; Karam, George

    2006-01-01

    The crystal structure of human adipocyte lipid-binding protein (aP2) with a bound palmitate is reported at 1.5 Å resolution. Human adipocyte lipid-binding protein (aP2) belongs to a family of intracellular lipid-binding proteins involved in the transport and storage of lipids. Here, the crystal structure of human aP2 with a bound palmitate is described at 1.5 Å resolution. Unlike the known crystal structure of murine aP2 in complex with palmitate, this structure shows that the fatty acid is in a folded conformation and that the loop containing Phe57 acts as a lid to regulate ligand binding by excluding solvent exposure to the central binding cavity

  8. APS ACTION--AntiPhospholipid Syndrome Alliance For Clinical Trials and InternatiOnal Networking.

    Science.gov (United States)

    Erkan, D; Lockshin, M D

    2012-06-01

    AntiPhospholipid Syndrome Alliance For Clinical Trials and InternatiOnal Networking (APS ACTION) is the first-ever international research network that has been created specifically to design and conduct well-designed, large-scale, multi-center clinical trials in persistently antiphospholipid antibody (aPL)-positive patients. The founding principle of the APS ACTION is that it is an internationally collaborative effort, open to qualified investigators across the globe who are committed to furthering our understanding of APS and its management. Due to the hard work and collaborative spirit of APS ACTION members, in early 2012, APS ACTION launched two important collaborative international projects: 1) a randomized controlled trial of hydroxychloroquine in the primary thrombosis prevention of persistently aPL-positive but thrombosis-free patients without other systemic autoimmune diseases; and 2) a web-based registry of aPL-positive patients with or without systemic autoimmune diseases, which will also include annual blood collection for aPL-testing and future basic science studies. In the end, we hope to find better treatments for antiphospholipid syndrome, which is a leading cause of thrombosis, pregnancy morbidity and other life-altering consequences, and to heighten awareness about this life-threatening, autoimmune condition.

  9. AP1S3 Mutations Are Associated with Pustular Psoriasis and Impaired Toll-like Receptor 3 Trafficking

    Science.gov (United States)

    Setta-Kaffetzi, Niovi; Simpson, Michael A.; Navarini, Alexander A.; Patel, Varsha M.; Lu, Hui-Chun; Allen, Michael H.; Duckworth, Michael; Bachelez, Hervé; Burden, A. David; Choon, Siew-Eng; Griffiths, Christopher E.M.; Kirby, Brian; Kolios, Antonios; Seyger, Marieke M.B.; Prins, Christa; Smahi, Asma; Trembath, Richard C.; Fraternali, Franca; Smith, Catherine H.; Barker, Jonathan N.; Capon, Francesca

    2014-01-01

    Adaptor protein complex 1 (AP-1) is an evolutionary conserved heterotetramer that promotes vesicular trafficking between the trans-Golgi network and the endosomes. The knockout of most murine AP-1 complex subunits is embryonically lethal, so the identification of human disease-associated alleles has the unique potential to deliver insights into gene function. Here, we report two founder mutations (c.11T>G [p.Phe4Cys] and c.97C>T [p.Arg33Trp]) in AP1S3, the gene encoding AP-1 complex subunit σ1C, in 15 unrelated individuals with a severe autoinflammatory skin disorder known as pustular psoriasis. Because the variants are predicted to destabilize the 3D structure of the AP-1 complex, we generated AP1S3-knockdown cell lines to investigate the consequences of AP-1 deficiency in skin keratinocytes. We found that AP1S3 silencing disrupted the endosomal translocation of the innate pattern-recognition receptor TLR-3 (Toll-like receptor 3) and resulted in a marked inhibition of downstream signaling. These findings identify pustular psoriasis as an autoinflammatory phenotype caused by defects in vesicular trafficking and demonstrate a requirement of AP-1 for Toll-like receptor homeostasis. PMID:24791904

  10. Lactitol and the maintenance of normal defecation: evaluation of a health claim pursuant to Article 13(5) of Regulation (EC) No 1924/2006

    DEFF Research Database (Denmark)

    Sjödin, Anders Mikael

    2015-01-01

    that the maintenance of normal defecation is a beneficial physiological effect. A total of 15 human intervention studies were identified as pertinent to the health claim. Twelve studies with various methodological limitations consistently showed that consumption of at least 10 g/day lactitol increases stool frequency......Following an application from DuPont Nutrition BioSciences ApS, submitted pursuant to Article 13(5) of Regulation (EC) No 1924/2006 via the Competent Authority of the United Kingdom, the Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to deliver an opinion on the scientific...... substantiation of a health claim related to lactitol and the maintenance of normal defecation. The food constituent that is the subject of the claim is lactitol. The Panel considers that the food constituent lactitol, which is the subject of the claim, is sufficiently characterised. The Panel considers...

  11. Piping benchmark problems for the Westinghouse AP600 Standardized Plant

    International Nuclear Information System (INIS)

    Bezler, P.; DeGrassi, G.; Braverman, J.; Wang, Y.K.

    1997-01-01

    To satisfy the need for verification of the computer programs and modeling techniques that will be used to perform the final piping analyses for the Westinghouse AP600 Standardized Plant, three benchmark problems were developed. The problems are representative piping systems subjected to representative dynamic loads with solutions developed using the methods being proposed for analysis for the AP600 standard design. It will be required that the combined license licensees demonstrate that their solutions to these problems are in agreement with the benchmark problem set

  12. ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2015-06-01

    Full Text Available ABSTRAK ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA. Kecelakaan yang diakibatkan oleh kehilangan pendingin (loss of coolant accident / LOCA dari sistem reaktor merupakan kejadian dasar desain yang tetap diantisipasi dalam desain reaktor daya yang mengadopsi teknologi Generasi II hingga IV. LOCA ukuran kecil (small break LOCA memiliki dampak yang lebih signifikan terhadap keselamatan dibandingkan LOCA ukuran besar (large break LOCA seperti terlihat pada kejadian Three-Mile Island (TMI. Fokus makalah adalah pada analisis small break LOCA pada reaktor daya maju Generasi III+ yaitu AP1000 dengan mensimulasikan tiga kejadian pemicu yaitu membukanya katup Automatic Depressurization System (ADS secara tak disengaja, putusnya salah satu pipa Direct Vessel Injection (DVI secara double-ended, dan putusnya pipa lengan dingin dengan diameter bocoran 10 inci. Metode yang digunakan adalah simulasi kejadian pada model AP1000 yang dikembangkan secara mandiri menggunakan program perhitungan RELAP5/SCDAP/Mod3.4. Dampak yang ingin dilihat adalah kondisi teras selama terjadinya small break LOCA yang terdiri dari pembentukan mixture level dan transien temperatur kelongsong bahan bakar. Hasil simulasi menunjukkan bahwa mixture level untuk semua kejadian small break LOCA berada di atas tinggi teras aktif yang menunjukkan tidak terjadinya core uncovery. Adanya mixture level berpengaruh pada transien temperatur kelongsong yang menurun dan menunjukkan pendinginan bahan bakar yang efektif. Hasil di atas juga identik dengan hasil perhitungan program lain yaitu NOTRUMP. Keefektifan pendinginan teras juga disebabkan oleh berfungsinya injeksi pendingin melalui fitur keselamatan pasif yang menjadi ciri reaktor daya AP1000. Secara keseluruhan, hasil analisis menunjukkan model AP1000 yang telah dikembangkan dengan RELAP5 dapat digunakan untuk keperluan analisis kecelakaan dasar desain pada reaktor daya maju AP1000. Kata kunci: analisis

  13. Structural modules in AP1000 plant design

    International Nuclear Information System (INIS)

    Prasad, N.; Tunon-Sanjur, L.

    2007-01-01

    Structural modules are extensively used in AP1000 plant design. The shop manufacturing of modules components improves the quality and reliability of plant structures. The application of modules has a positive impact on construction schedules, and results in substantial savings in the construction cost. This paper describes various types of structural modules used for AP1000 plant structures. CA structural wall modules are steel plate modules with concrete placed, on or within the module, after module installation. The layout and design of the largest CA wall modules, CA01 and CA20, is described in detail. General discussion of structural floor modules, such as the composite and finned floors, is also included. Steel form CB modules (liners) consist of plate reinforced with angle stiffeners and tee sections. The angles and the tee sections are on the concrete side of the plate. Design of CB20 has been included as an example of CB type modules. Design codes and structural concepts related to module designs are discussed. (authors)

  14. Real-time orbit feedback at the APS

    International Nuclear Information System (INIS)

    Carwardine, J.A.; Lenkszus, F.R.

    1998-01-01

    A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30 Hz by a factor of four to below 5 μm rms horizontally and 2 μm rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit motion. copyright 1998 American Institute of Physics

  15. Real-time orbit feedback at the APS.

    Energy Technology Data Exchange (ETDEWEB)

    Carwardine, J.

    1998-06-18

    A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit motion.

  16. RELAP5/MOD3 AP600 problems

    International Nuclear Information System (INIS)

    Riemke, R.A.

    1993-01-01

    RELAP5/MOD3 is a reactor systems analysis code that has been developed jointly by the US Nuclear Regulatory Commission (USNRC) and a consortium consisting of several of the countries and domestic organizations that were members of the International Code Assessment and Applications Program (ICAP). The code is currently being used to simulate transients for the next generation of advanced light water reactors (ALWR's). One particular reactor design is the Westinghouse AP600 pressurized water reactor (PWR), which consists of two hot legs and four cold legs as well as passive emergency core cooling (ECC) systems. Initial calculations with RELAP5/MOD3 indicated that the code was not as robust as RELAP5/MOD2.5 with regard to AP600 calculations. Recent modifications in the areas of condensation wall heat transfer, interfacial heat transfer in the presence of noncondensibles, bubbly flow interfacial heat transfer, and time smoothing of both interfacial drag and interfacial heat transfer have improved the robustness, although more reliability is needed

  17. Health in All Policies (HiAP) framework for country action.

    Science.gov (United States)

    2014-06-01

    This document serves as a 'starter's kit' for applying Health in All Policies (HiAP) in decision-making and implementation at national and subnational levels. It can be easily adapted for use in different country contexts and at the regional and global levels. WHAT IS HIAP?: HiAP is an approach to public policies across sectors that systematically takes into account the health implications of decisions, seeks synergies and avoids harmful health impacts in order to improve population health and health equity. As a concept, it reflects the principles of: legitimacy, accountability, transparency and access to information, participation, sustainability and collaboration across sectors and levels of government. Health and health equity are values in their own right and are also important prerequisites for achieving many other societal goals. Many of the determinants of health and health inequities in populations have social, environmental and economic origins that extend beyond the direct influence of the health sector and health policies. Thus, public policies in all sectors and at different levels of governance can have a significant impact on population health and health equity. The Framework sets out six key components that should be addressed in order to put the HiAP approach into action: (1) establish the need and priorities for HiAP, (2) frame planned action, (3) identify supportive structures and processes, (4) facilitate assessment and engagement, (5) ensure monitoring, evaluation and reporting, (6) build capacity. These components are not fixed in order or priority. Rather, individual countries will adopt and adjust the components in ways that are most relevant for their specific governance, economic and social contexts. Although governments as a whole bear the ultimate responsibility for the health of their citizens, health authorities at all levels are key actors in promoting HiAP. They should therefore actively seek opportunities to collaborate with and

  18. APS, an adaptor molecule containing PH and SH2 domains, has a negative regulatory role in B cell proliferation

    International Nuclear Information System (INIS)

    Iseki, Masanori; Kubo-Akashi, Chiyomi; Kwon, Sang-Mo; Yamaguchi, Akiko; Takatsu, Kiyoshi; Takaki, Satoshi

    2005-01-01

    Adaptor molecule containing PH and SH2 domains (APS) is an intracellular adaptor protein that forms part of an adaptor family along with Lnk and SH2-B. APS transcripts are expressed in various tissues including brain, kidney, and muscle, as well as in splenic B cells but not in T cells. We investigated the functions of APS in B cell development and activation by generating APS-transgenic (APS-Tg) mice that overexpressed APS in lymphocytes. The number of B-1 cells in the peritoneal cavity was reduced in APS-Tg mice, as were B-2 cells in the spleen. B cell development in the bone marrow was partially impaired at the transition stage from proliferating large pre-B to small pre-B cells. B cell proliferation induced by B cell receptor (BCR) crosslinking but not by other B cell mitogens was also impaired in APS-Tg mice. APS co-localized with BCR complexes and filamentous actin in activated APS-Tg B cells. Thus, APS appears to play novel negative regulatory roles in BCR signaling, actin reorganization pathways, and control of compartment sizes of B-lineage cells

  19. Nuclear AP4A-binding activity of sea urchin embryos changes in relation to the initiation of S phase

    International Nuclear Information System (INIS)

    Morioka, M.; Shimada, H.

    1986-01-01

    The AP 4 A-binding activity of sea urchin embryos was studied using radioactively labelled diadenosine 5', 5'''-P 1 ,P 4 -tetraphosphate (Ap 4 A). Among various subcellular components that can bind [ 3 H]AP 4 A, nuclei alone showed the highly specific Ap 4 A-binding activity which was not influenced by the presence of AP 4 A, AP 5 A and GP 4 G. The addition of an excess amount of ATP only slightly reduced the binding of [ 3 H]AP 4 A to the nuclei. It was found that AP 4 A binds to the residual proteinaceous structure of nuclei which was resistant to the extraction with 2 M NaCl. The nuclear AP 4 A-binding activity fluctuated cyclically during each cell cycle, with at transient increase at the beginning of S phase followed by an abrupt-decrease within 10 min. When the initiation of S phase was blocked, the increase in the AP 4 A-binding activity was also prevented. It seems that the binding of AP 4 A to the nuclear structural protein is involved in the initiation of S phase

  20. Synthesis and properties of ApA analogues with shortened phosphonate internucleotide linkage.

    Science.gov (United States)

    Králíková, Sárka; Buděšínský, Miloš; Barvík, Ivan; Masojídková, Milena; Točík, Zdeněk; Rosenberg, Ivan

    2011-01-01

    A complete series of the 2 '-5 ' and 3 '-5 ' regioisomeric types of r(ApA) and 2 '-d(ApA) analogues with the α-hydroxy-phosphonate C3 '-O-P-CH(OH)-C4 ″ internucleotide linkage, isopolar but non-isosteric with the phosphodiester one, were synthesized and their hybridization properties with polyU studied. Due to the chirality on the 5 '-carbon atom of the modified internucleotide linkage bearing phosphorus and hydroxy moieties, each regioisomeric type of ApA dimer is split into epimeric pairs. To examine the role of the 5 '-hydroxyl of the α-hydroxy-phosphonate moiety during hybridization, the appropriate r(ApA) analogues with 3 '(2 ')-O-P-CH(2)-C4 ″ linkage lacking the 5 '-hydroxyl were synthesized. Nuclear magnetic resonance (NMR) spectroscopy study on the conformation of the modified sugar-phosphate backbone, along with the hybridization measurements, revealed remarkable differences in the stability of complexes with polyU, depending on the 5 '-carbon atom configuration. Potential usefulness of the α-hydroxy-phosphonate linkage in modified oligoribonucleotides is discussed.

  1. The link between the use of advanced planning and scheduling (APS) modules and factory context

    DEFF Research Database (Denmark)

    Kristensen, Jesper; Asmussen, Jesper Normann; Wæhrens, Brian Vejrum

    2017-01-01

    at factories characterized by low planning maturity, but lower for factories with medium planning maturity. For low planning maturity, the APS module is used for improving the configuration of the manufacturing system, whereas high planning maturity is required to capture performance benefits from optimization......Through a study of four embedded action research cases within a global OEM, it is investigated how the frequency of use and contribution of an Advanced Planning and Scheduling (APS) module are affected by factory context. The performance contribution of the APS module is found to be high...... and scenario planning. Further, it is found that planning complexity at the factory increases both the frequency of use and the contribution of using APS modules. On the basis of the findings, three propositions are formulated on the link between factory context and the use of APS module....

  2. Interactome analysis of transcriptional coactivator multiprotein bridging factor 1 unveils a yeast AP-1-like transcription factor involved in oxidation tolerance of mycopathogen Beauveria bassiana.

    Science.gov (United States)

    Chu, Xin-Ling; Dong, Wei-Xia; Ding, Jin-Li; Feng, Ming-Guang; Ying, Sheng-Hua

    2018-02-01

    Oxidation tolerance is an important determinant to predict the virulence and biocontrol potential of Beauveria bassiana, a well-known entomopathogenic fungus. As a transcriptional coactivator, multiprotein bridging factor 1 mediates the activity of transcription factor in diverse physiological processes, and its homolog in B. bassiana (BbMBF1) contributes to fungal oxidation tolerance. In this study, the BbMBF1-interactomes under oxidative stress and normal growth condition were deciphered by mass spectrometry integrated with the immunoprecipitation. BbMBF1p factor has a broad interaction with proteins that are involved in various cellular processes, and this interaction is dynamically regulated by oxidative stress. Importantly, a B. bassiana homolog of yeast AP-1-like transcription factor (BbAP-1) was specifically associated with the BbMBF1-interactome under oxidation and significantly contributed to fungal oxidation tolerance. In addition, qPCR analysis revealed that several antioxidant genes are jointly controlled by BbAP-1 and BbMBF1. Conclusively, it is proposed that BbMBF1p protein mediates BbAP-1p factor to transcribe the downstream antioxidant genes in B. bassiana under oxidative stress. This study demonstrates for the first time a proteomic view of the MBF1-interactome in fungi, and presents an initial framework to probe the transcriptional mechanism involved in fungal response to oxidation, which will provide a new strategy to improve the biocontrol efficacy of B. bassiana.

  3. Obstetrical APS : Is there a place for hydroxychloroquine to improve the pregnancy outcome?

    NARCIS (Netherlands)

    Mekinian, Arsene; Costedoat-Chalumeau, Nathalie; Masseau, Agathe; Tincani, Angela; De Caroli, Sara; Alijotas-Reig, Jaume; Ruffatti, Amelia; Ambrozic, Ales; Botta, Angela; Le Guern, Véronique; Fritsch-Stork, Ruth; Nicaise-Roland, Pascale; Carbonne, Bruno; Carbillon, Lionel; Fain, Olivier

    2015-01-01

    The use of the conventional APS treatment (the combination of low-dose aspirin and LMWH) dramatically improved the obstetrical prognosis in primary obstetrical APS (OAPS). The persistence of adverse pregnancy outcome raises the need to find other drugs to improve obstetrical outcome.

  4. Fuzzy uncertainty modeling applied to AP1000 nuclear power plant LOCA

    International Nuclear Information System (INIS)

    Ferreira Guimaraes, Antonio Cesar; Franklin Lapa, Celso Marcelo; Lamego Simoes Filho, Francisco Fernando; Cabral, Denise Cunha

    2011-01-01

    Research highlights: → This article presents an uncertainty modelling study using a fuzzy approach. → The AP1000 Westinghouse NPP was used and it is provided of passive safety systems. → The use of advanced passive safety systems in NPP has limited operational experience. → Failure rates and basic events probabilities used on the fault tree analysis. → Fuzzy uncertainty approach was employed to reliability of the AP1000 large LOCA. - Abstract: This article presents an uncertainty modeling study using a fuzzy approach applied to the Westinghouse advanced nuclear reactor. The AP1000 Westinghouse Nuclear Power Plant (NPP) is provided of passive safety systems, based on thermo physics phenomenon, that require no operating actions, soon after an incident has been detected. The use of advanced passive safety systems in NPP has limited operational experience. As it occurs in any reliability study, statistically non-significant events report introduces a significant uncertainty level about the failure rates and basic events probabilities used on the fault tree analysis (FTA). In order to model this uncertainty, a fuzzy approach was employed to reliability analysis of the AP1000 large break Loss of Coolant Accident (LOCA). The final results have revealed that the proposed approach may be successfully applied to modeling of uncertainties in safety studies.

  5. Tank 241-AP-107 tank characterization plan

    International Nuclear Information System (INIS)

    Schreiber, R.D.

    1994-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, and PNL 325 Analytical Chemistry Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples from tank 241-AP-107

  6. Ten colour photometry of twelve Ap-stars

    International Nuclear Information System (INIS)

    Musielok, B.; Lange, D.; Schoeneich, W.; Hildebrandt, G.; Zelwanowa, E.; Hempelmann, A.; Salmanov, G.

    1980-01-01

    Ten-colour photoelectric observations are presented for twelve Ap-stars. Improved ephemeris for seven of them is given. Phase relations between the light curves and line intensity variations are discussed. The problem of the electromagnetic flux conctancy of IOTA Cas is approached from a qualitative point of view. (author)

  7. Initial performance assessment of the Westinghouse AP600 containment design and related safety issues

    International Nuclear Information System (INIS)

    Nicolette, V.F.; Washington, K.E.; Tills, J.L.

    1991-01-01

    This work summarizes the Westinghouse AP600 advanced reactor design assessment calculations performed to date with the CONTAIN code. Correlations for modeling the important heat transfer phenomena are discussed as well. A CONTAIN model of the AP600 was constructed for design basis accident (DBA) calculations. Insights gained from modeling of the smaller-scale Westinghouse Integral Test Facility were incorporated in the development of the AP600 model. The results of the DBA calculations are compared to the results of other researchers to serve as a point of reference for future severe accident calculations. The CONTAIN calculations are reviewed to examine several parameters/phenomena of interest. The results of the calculations are also used to identify limitations of the CONTAIN code regarding application to advanced reactor containment designs. The most recent heat transfer correlations available in the literature are assessed for use in the flow regimes and geometries applicable to the AP600. Use of one of these correlations in CONTAIN may allow for a more accurate assessment of the AP600

  8. Adaptor Protein Complex 2 (AP-2) Mediated, Clathrin Dependent Endocytosis, And Related Gene Activities, Are A Prominent Feature During Maturation Stage Amelogenesis

    Science.gov (United States)

    LACRUZ, Rodrigo S.; BROOKES, Steven J.; WEN, Xin; JIMENEZ, Jaime M.; VIKMAN, Susanna; HU, Ping; WHITE, Shane N.; LYNGSTADAAS, S. Petter; OKAMOTO, Curtis T.; SMITH, Charles E.; PAINE, Michael L.

    2012-01-01

    Molecular events defining enamel matrix removal during amelogenesis are poorly understood. Early reports have suggested that adaptor proteins (AP) participate in ameloblast-mediated endocytosis. Enamel formation involves the secretory and maturation stages, with an increase in resorptive function during the latter. Here, using real time PCR, we show that the expression of clathrin and adaptor protein subunits are up-regulated in maturation stage rodent enamel organ cells. AP-2 is the most up-regulated of the four distinct adaptor protein complexes. Immunolocalization confirms the presence of AP-2 and clathrin in ameloblasts with strongest reactivity at the apical pole. These data suggest that the resorptive functions of enamel cells involve AP-2 mediated, clathrin dependent endocytosis, thus implying the likelihood of a specific membrane-bound receptor(s) of enamel matrix protein debris. The mRNA expression of other endocytosis-related gene products is also up-regulated during maturation including: lysosomal-associated membrane protein 1 (Lamp1), cluster of differentiation 63 and 68 (Cd63 and Cd68), ATPase, H+ transporting, lysosomal V0 subunit D2 (Atp6v0d2), ATPase, H+ transporting, lysosomal V1 subunit B2 (Atp6v1b2), chloride channel, voltage-sensitive 7 (Clcn7) and cathepsin K (Ctsk). Immunohistological data confirms the expression of a number of these proteins in maturation stage ameloblasts. The enamel of Cd63-null mice was also examined. Despite increased mRNA and protein expression in the enamel organ during maturation, the enamel of Cd63-null mice appeared normal. This may suggest inherent functional redundancies between Cd63 and related gene products, such as Lamp1 and Cd68. Ameloblast-like LS8 cells treated with the enamel matrix protein complex Emdogain® showed up-regulation of AP-2 and clathrin subunits, further supporting the existence of a membrane-bound receptor regulated pathway for the endocytosis of enamel matrix proteins. These data together

  9. An Insider's History of Some of the Significant Changes In the APS from the 1960s to Today

    Science.gov (United States)

    Schwartz, Brian

    2014-03-01

    It has been over 50 years since I first joined the American Physical Society. A lot has changed. The APS in the 60s did not have a single Forum and all divisions were related to sub-field of physics research plus the History of Physics Division. The APS governance and meeting's structure did not provide for issues relate to physics and society, undergraduate and graduate education, minorities, women, industrial physics, international physics, communication of science, and many more subjects quite typical of APS in 2014. From the start, I was a very active member of APS and one of the original petitioners for the Division on Physics and Society. Ultimately this led to the APS Forum structure, the Panel on Public Affairs and many APS formal committees. Two of the major impetuses for change in the late 60s were the need to debate the role of science in the unpopular war in Vietnam and the overproduction and poor employment prospects for new Ph.D.s. I, and colleagues, (with little original encouragement from the APS leadership), arranged for the discussion on many new topics at the meeting and proposed changes within the governance of the Society. In the late 1980s I joined the APS and was involved in many changes over the next 20 years. ultimately as Associate Executive Officer and Director of the APS Centennial in 1999. As indicated earlier, I've been with the APS for over 50 years and will present its history as a participant-insider. Topic covered include my surprise election to the APS governance in 1972, the establishment of the Forum on Physics and Society (and the restrictions imposed on its governance), my role as the father (or mother) of the women's movement at APS, the complexities and politics of the move of APS headquarters from New York to College Park, the establishment of the tabloid APS News and many more subjects. Currently I am producing staged-readings of science-based plays at the March and April 2014 APS meetings for the Forum on History of

  10. The surface distribution of chemical anomalies of Ap components in detached close binaries

    International Nuclear Information System (INIS)

    Kitamura, M.

    1980-01-01

    By estimating the orbital inclinations of non-eclipsing detached close binaries with Ap spectra, a marked statistical preference is obtained on the frequency distribution of the inclination which suggests that the abundance anomalies of Ap components tend to concentrate towards the stellar polar region. (Auth.)

  11. [6]-Gingerol induces caspase-dependent apoptosis and prevents PMA-induced proliferation in colon cancer cells by inhibiting MAPK/AP-1 signaling.

    Directory of Open Access Journals (Sweden)

    E K Radhakrishnan

    Full Text Available We report mechanism-based evidence for the anticancer and chemopreventive efficacy of [6]-gingerol, the major active principle of the medicinal plant, Ginger (Zingiber officinale, in colon cancer cells. The compound was evaluated in two human colon cancer cell lines for its cytotoxic effect and the most sensitive cell line, SW-480, was selected for the mechanistic evaluation of its anticancer and chemopreventive efficacy. The non-toxic nature of [6]-gingerol was confirmed by viability assays on rapidly dividing normal mouse colon cells. [6]-gingerol inhibited cell proliferation and induced apoptosis as evidenced by externalization of phosphatidyl serine in SW-480, while the normal colon cells were unaffected. Sensitivity to [6]-gingerol in SW-480 cells was associated with activation of caspases 8, 9, 3 &7 and cleavage of PARP, which attests induction of apoptotic cell death. Mechanistically, [6]-gingerol down-regulated Phorbol Myristate Acetate (PMA induced phosphorylation of ERK1/2 and JNK MAP kinases and activation of AP-1 transcription factor, but had only little effects on phosphorylation of p38 MAP kinase and activation of NF-kappa B. Additionally, it complemented the inhibitors of either ERK1/2 or JNK MAP kinase in bringing down the PMA-induced cell proliferation in SW-480 cells. We report the inhibition of ERK1/2/JNK/AP-1 pathway as a possible mechanism behind the anticancer as well as chemopreventive efficacy of [6]-gingerol against colon cancer.

  12. Clinical relevance of β₂-glycoprotein-I plasma levels in antiphospholipid syndrome (APS).

    Science.gov (United States)

    Banzato, Alessandra; Pengo, Vittorio

    2014-06-01

    Antiphospholipid syndrome (APS) is characterized by the presence of antiphospholipid (aPL) antibodies associated with thrombosis or pregnancy morbidity. The antibodies mainly involved in this disorder are directed against β2-glycoprotein I (β2-GPI). β2-GPI plasma level is usually not reported in studies on APS, because it is not regarded as relevant to the diagnosis and prognosis of APS. Nevertheless its measurement may be important for understanding the pathophysiology of the syndrome. This review summarizes available data from the literature on plasma concentrations of β2-GPI in patients with different antibody profiles.

  13. Preparation and characterization of superfine ammonium perchlorate (AP) crystals through ceramic membrane anti-solvent crystallization

    Science.gov (United States)

    Ma, Zhenye; Li, Cheng; Wu, Rujun; Chen, Rizhi; Gu, Zhenggui

    2009-10-01

    In this paper, a novel ceramic membrane anti-solvent crystallization (CMASC) method was proposed for the safe and rapid preparation ammonium perchlorate (AP) crystals, in which the acetone and ethyl acetate were chosen as solvent and anti-solvent, respectively. Comparing with the conventional liquid anti-solvent crystallization (LASC), CMASC which successfully introduces ceramic membrane with regular pore structure to the LASC as feeding medium, is favorable to control the rate of feeding rate and, therefore, to obtain size and morphology controllable AP. Several kinds of micro-sized AP particles with different morphology were obtained including polyhedral-like, quadrate-like to rod-like. The effect of processing parameters on the crystal size and shape of AP crystals such as volume ratio of anti-solvent to solvent, feeding pressure and crystallization temperature were investigated. It is found that higher volume ratio of anti-solvent to solvent, higher feeding pressure and higher temperature result in smaller particle size. Scaning electron microscopy (SEM) and X-ray diffraction (XRD) were used to characterize the resulting AP crystals. The nucleation and growth kinetic of the resulting AP crystals were also discussed.

  14. A Sleep-Awake Scheme Based on CoAP for Energy-Efficiency in Internet of Things

    Directory of Open Access Journals (Sweden)

    Wenquan Jin

    2017-11-01

    Full Text Available Internet Engineering Task Force (IETF have developed Constrained Application Protocol (CoAP to enable communication between sensor or actuator nodes in constrained environments, such as small amount of memory, and low power. IETF CoAP and HTTP are used to monitor or control environments in Internet of Things (IoT and Machine-to-Machine (M2M. In this paper, we present a sleep-awake scheme based on CoAP for energy efficiency in Internet of Things. This scheme supports to increase energy efficiency of IoT nodes using CoAP protocol. We have slightly modified the IoT middleware to improve CoAP protocol to conserve energy in the IoT nodes. Also, the IoT middleware includes some functionality of the CoRE Resource Directory (RD and the Message Queue (MQ broker with IoT nodes to synchronize sleepy status.

  15. Research on quality assurance classification methodology for domestic AP1000 nuclear power projects

    International Nuclear Information System (INIS)

    Bai Jinhua; Jiang Huijie; Li Jingyan

    2012-01-01

    To meet the quality assurance classification requirements of domestic nuclear safety codes and standards, this paper analyzes the quality assurance classification methodology of domestic AP1000 nuclear power projects at present, and proposes the quality assurance classification methodology for subsequent AP1000 nuclear power projects. (authors)

  16. Cloning and Molecular Characterization of the Schistosoma mansoni Genes RbAp48 and Histone H4

    Directory of Open Access Journals (Sweden)

    Patrícia P Souza

    2002-10-01

    Full Text Available The human nuclear protein RbAp48 is a member of the tryptophan/aspartate (WD repeat family, which binds to the retinoblastoma (Rb protein. It also corresponds to the smallest subunit of the chromatin assembly factor and is able to bind to the helix 1 of histone H4, taking it to the DNA in replication. A cDNA homologous to the human gene RbAp48 was isolated from a Schistosoma mansoni adult worm library and named SmRbAp48. The full length sequence of SmRbAp48 cDNA is 1036 bp long, encoding a protein of 308 amino acids. The transcript of SmRbAp48 was detected in egg, cercariae and schistosomulum stages. The protein shows 84% similarity with the human RbAp48, possessing four WD repeats on its C-terminus. A hypothetical tridimensional structure for the SmRbAp48 C-terminal domain was constructed by computational molecular modeling using the b-subunit of the G protein as a model. To further verify a possible interaction between SmRbAp48 and S. mansoni histone H4, the histone H4 gene was amplified from adult worm genomic DNA using degenerated primers. The gene fragment of SmH4 is 294 bp long, encoding a protein of 98 amino acids which is 100% identical to histone H4 from Drosophila melanogaster.

  17. Algoritmo para el 4ap haciendo uso de la metaheuristica sistema hormiga

    Directory of Open Access Journals (Sweden)

    Manuel Vicente Centeno Romero

    2008-07-01

    Full Text Available La metaheurística sistema hormiga consiste en la analogía entre el procedimiento que utilizan las hormigas reales para la búsqueda de alimentos, encontrando la ruta más corta, y los problemas de optimización combinatoria para encontrar la mejor solución. Entre estos problemas se encuentra el de asignación multidimensional (mAP, el cual es un problema NP-difícil para m > 2. En la actualidad no se ha desarrollado trabajo alguno sobre el 4AP (mAP con m=4, tampoco existe publicación sobre la aplicación del sistema hormiga para el mAP. En este trabajo se desarrolló un software que hace uso de la metaheurística sistema hormiga para encontrar la mejor solución o aproximada al 4AP, con problemas generados aleatoriamente. Se implementó una metodología híbrida entre la metodología de Investigación de Operaciones descrita por Taha (1991 y la ingeniería de software (1990. El número de asignaciones tomadas en cuenta para verificar qué tan buenas son las soluciones arrojadas por el software, varía desde n=2 hasta n=25, obteniéndose soluciones exactas para 2 £ n £ 6, ya que al compararse dichas soluciones con las dadas por XPRESS (software de programación lineal que se usa para resolver modelos matemáticos se observa la igualdad en los resultados. Para n _ 7, XPRESS (la versión utilizada no ofrece respuesta alguna, pero el software desarrollado arroja buenos resultados en un tiempo computacional razonable, considerando el número de asignaciones que se procesan en cada n. The metaheuristic ant system consists on the analogy among the procedure used by the real ants for searching food, for finding the shortest route; and the problems of combinatoria optimization to find the best solution. Among these problems we can find the multidimensional assignment problem (mAP, which is a NP-difficult problem for m > 2. At the present time, there isn‘t any work that has been developed, on this topic about the 4AP (mAP with m=4, neither

  18. [Obstetrical APS: Is there a place for additional treatment to aspirin-heparin combination?

    Science.gov (United States)

    Mekinian, A; Kayem, G; Cohen, J; Carbillon, L; Abisror, N; Josselin-Mahr, L; Bornes, M; Fain, O

    2017-01-01

    Obstetrical APS is defined by thrombosis and/or obstetrical morbidity associated with persistent antiphospholipid antibodies. The aspirin and low molecular weighted heparin combination dramatically improved obstetrical outcome in APS patients. Several factors could be associated with obstetrical prognosis, as previous history of thrombosis, associated SLE, the presence of lupus anticoagulant and triple positivity of antiphospholipid antibodies. Obstetrical APS with isolated recurrent miscarriages is mostly associated with isolated anticardiolipids antibodies and have better obstetrical outcome. The pregnancy loss despite aspirin and heparin combination define the refractory obstetrical APS, and the prevalence could be estimated to 20-39%. Several other treatments have been used in small and open labeled studies, as steroids, intravenous immunoglobulins, plasma exchanges and hydroxychloroquine to improve the obstetrical outcome. Some other drugs as eculizumab and statins could also have physiopathological rational, but studies are necessary to define the place of these various drugs. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Automated Plasma Spray (APS) process feasibility study: Plasma spray process development and evaluation

    Science.gov (United States)

    Fetheroff, C. W.; Derkacs, T.; Matay, I. M.

    1979-01-01

    An automated plasma spray (APS) process was developed to apply two layer (NiCrAlY and ZrO2-12Y2O3) thermal-barrier coatings to aircraft gas turbine engine blade airfoils. The APS process hardware consists of four subsystems: a mechanical blade positioner incorporating two interlaced six-degree-of-freedom assemblies; a noncoherent optical metrology subsystem; a microprocessor-based adaptive system controller; and commercial plasma spray equipment. Over fifty JT9D first stage turbine blades specimens were coated with the APS process in preliminary checkout and evaluation studies. The best of the preliminary specimens achieved an overall coating thickness uniformity of + or - 53 micrometers, much better than is achievable manually. Factors limiting this performance were identified and process modifications were initiated accordingly. Comparative evaluations of coating thickness uniformity for manually sprayed and APS coated specimens were initiated. One of the preliminary evaluation specimens was subjected to a torch test and metallographic evaluation.

  20. PREFACE: Asia-Pacific Interdisciplinary Research Conference 2011 (AP-IRC 2011)

    Science.gov (United States)

    Sandhu, Adarsh; Okada, Hiroshi; Maekawa, Toru; Okano, Ken

    2012-03-01

    AP-IRC Logo Scientists, engineers, entrepreneurs and policymakers gather at the first truly interdisciplinary conference held in Asia-Pacific http://www.apirc.jp/ The inaugural Asia-Pacific Interdisciplinary Research Conference 2011 (AP-IRC 2011) was held at Toyohashi University of Technology (Toyohashi Tech) on 17-18 November 2011. The conference is a forum for enhancing mutual understanding between scientists, engineers, policymakers and experts from a wide spectrum of pure and applied sciences, to resolve the daunting global issues facing mankind. The conference attracted approximately 300 participants including delegates from France, Germany, India, Indonesia, Korea, Malaysia, Russia, Sweden, United Kingdom, USA and Vietnam. AP-IRC 2011 was chaired by Dr Yoshiyuki Sakaki, President of Toyohashi Tech, who opened the proceedings by stressing the importance of an interdisciplinary approach to research, to resolve global scientific and technical issues. Recalling his own experience as the leader of Japan's efforts in the Human Genome Project, Sakaki also encouraged participants to make an effort to try to understand the sometimes difficult concepts and terminology of other areas of research. The presentations at AP-IRC 2011 were divided into three focus sessions: innovative mechano-magneto-electronic systems, life sciences, and green science and technology. A total of 174 papers were presented over the two-day conference including eight by invited speakers. Highlights of AP-IRC 2011 included a first-hand account of the damage caused by the massive earthquake in March 2011 to experimental facilities at Tohoku University by Masayoshi Esashi; the fascinating world of bees and the inborn numerical competence of humans and animals by Hans J Gross; research on robots and cognition-enabled technical systems at Technische Universität München by Sandra Hirche; the history of events leading to the invention of the world's strongest NdFeB permanent magnet by Masato Sagawa

  1. K-Nearest Neighbor Intervals Based AP Clustering Algorithm for Large Incomplete Data

    Directory of Open Access Journals (Sweden)

    Cheng Lu

    2015-01-01

    Full Text Available The Affinity Propagation (AP algorithm is an effective algorithm for clustering analysis, but it can not be directly applicable to the case of incomplete data. In view of the prevalence of missing data and the uncertainty of missing attributes, we put forward a modified AP clustering algorithm based on K-nearest neighbor intervals (KNNI for incomplete data. Based on an Improved Partial Data Strategy, the proposed algorithm estimates the KNNI representation of missing attributes by using the attribute distribution information of the available data. The similarity function can be changed by dealing with the interval data. Then the improved AP algorithm can be applicable to the case of incomplete data. Experiments on several UCI datasets show that the proposed algorithm achieves impressive clustering results.

  2. Lactogenic differentiation of HC11 cells is not accompanied by downregulation of AP-2 transcription factor genes

    Directory of Open Access Journals (Sweden)

    Schorle Hubert

    2008-06-01

    Full Text Available Abstract Background During pregnancy the mammary epithelium undergoes a complex developmental process which culminates in the generation of the milk-secreting epithelium. Secretory epithelial cells display lactogenic differentiation which is characterized by the expression of milk protein genes, such as beta-casein or whey acidic protein (WAP. Transcription factors AP-2alpha and AP-2gamma are downregulated during lactation, and their overexpression in transgenic mice impaired the secretory differentiation of the mammary epithelium, resulting in lactation failure. To explore whether the downregulation of AP-2alpha and AP-2gamma is of functional significance for lactogenic differentiation, we analyzed the expression of the AP-2 family members during the lactogenic differentiation of HC11 mammary epithelial cells in vitro. Differentiation of HC11 cells was induced following established protocols by applying the lactogenic hormones prolactin, dexamethasone and insulin. Findings HC11 cells express all AP-2 family members except AP-2delta. Using RT-PCR we could not detect a downregulation of any of these genes during the lactogenic differentiation of HC11 cells in vitro. This finding was confirmed for AP-2alpha and AP-2gamma using Northern analysis. Differentiating HC11 cells displayed lower expression levels of milk protein genes than mammary glands of mid-pregnant or lactating mice. Conclusion The extent of lactogenic differentiation of HC11 cells in vitro is limited compared to mammary epithelium undergoing secretory differentiation in vivo. Downregulation of AP-2 transcription factor genes is not required for lactogenic differentiation of HC11 cells but may functionally be involved in aspects of lactogenic differentiation in vivo that are not reflected by the HC11 system.

  3. Thrombin activatable fibrinolysis inhibitor (TAFI) - A possible link between coagulation and complement activation in the antiphospholipid syndrome (APS).

    Science.gov (United States)

    Grosso, Giorgia; Vikerfors, Anna; Woodhams, Barry; Adam, Mariette; Bremme, Katarina; Holmström, Margareta; Ågren, Anna; Eelde, Anna; Bruzelius, Maria; Svenungsson, Elisabet; Antovic, Aleksandra

    2017-10-01

    Thrombosis and complement activation are pathogenic features of antiphospholipid syndrome (APS). Their molecular link is Plasma carboxypeptidase-B, also known as thrombin activatable fibrinolysis inhibitor (TAFIa), which plays a dual role: anti-fibrinolytic, by cleaving carboxyl-terminal lysine residues from partially degraded fibrin, and anti-inflammatory, by downregulating complement anaphylatoxins C3a and C5a. To investigate the levels of TAFI (proenzyme) and TAFIa (active enzyme) in relation to complement activation, fibrin clot permeability and fibrinolytic function in clinical and immunological subsets of 52 APS patients and 15 controls. TAFI (pAPS patients compared to controls. Furthermore, TAFIa was increased (pAPS patients affected by arterial thrombosis compared to other APS-phenotypes. Positive associations were found between TAFI and age, fibrinogen and C5a, and between TAFIa and age, fibrinogen and thrombomodulin. TAFI and TAFIa levels were increased in patients with APS as a potential response to complement activation. Interestingly, TAFI activation was associated with arterial thrombotic APS manifestations. Thus, TAFIa may be considered a novel biomarker for arterial thrombosis in APS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. AP600 passive containment cooling system phenomena identification and ranking table

    International Nuclear Information System (INIS)

    Spencer, D.R.; Woodcock, Joel

    1999-01-01

    This paper presents the Phenomena Identification and Ranking Table (PIRT) used in the containment Design Basis Analysis (DBA) for the AP600 nuclear power plant. The PIRT is a tool generally applied to best estimate thermal hydraulic analyses. In the conservative analytical modeling approach used for the AP600 DBA containment pressure response, the PIRT was a tool used to show completeness and relevance of the test database in accordance with the Code of Federal Regulations for advanced plant design. Additionally, the ranking of phenomena by relative importance in a PIRT allows appropriate focusing of resources during model development and licensing review. The focus of the paper is on the organization and structure of the PIRT to show level of detail and format accepted for the AP600, for potential application to other containment designs or accident scenarios. Conclusions of general interest are discussed regarding table organization and structure, the process for developing relative ranking and incorporating expert opinion, and the definition and usage of the relative ranking in support of the conservative evaluation model. The AP600 containment evaluation model approach, as influenced by the relative rankings, is briefly described to put into context this unique application of the PIRT to a conservative methodology. The bases for relative ranking of each phenomenon, which included expert opinion, and quantitative results of scaling and testing, was submitted to the NRC as part of AP600-specific evaluations. Since a PIRT supports the sufficiency of both a testing program and analytical modeling, the process followed to generate and confirm the PIRT, an important part of the licensing acceptance, was a focus of extensive NRC review. General descriptions of key phenomena are provided to aid in understanding the containment PIRT for more general applications for containment evaluations of other PWR designs or for other scenarios. (author)

  5. APS high heat load monochromator

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.

    1993-02-01

    This document contains the design specifications of the APS high heat load (HHL) monochromator and associated accessories as of February 1993. It should be noted that work is continuing on many parts of the monochromator including the mechanical design, crystal cooling designs, etc. Where appropriate, we have tried to add supporting documentation, references to published papers, and calculations from which we based our decisions. The underlying philosophy behind performance specifications of this monochromator was to fabricate a device that would be useful to as many APS users as possible, that is, the design should be as generic as possible. In other words, we believe that this design will be capable of operating on both bending magnet and ID beamlines (with the appropriate changes to the cooling and crystals) with both flat and inclined crystal geometries and with a variety of coolants. It was strongly felt that this monochromator should have good energy scanning capabilities over the classical energy range of about 4 to 20 keywith Si (111) crystals. For this reason, a design incorporating one rotation stage to drive both the first and second crystals was considered most promising. Separate rotary stages for the first and second crystals can sometimes provide more flexibility in their capacities to carry heavy loads (for heavily cooled first crystals or sagittal benders of second crystals), but their tuning capabilities were considered inferior to the single axis approach

  6. The APS x-ray undulator photon beam position monitor and tests at CHESS and NSLS

    International Nuclear Information System (INIS)

    Shu, D.; Rodricks, B.; Barraza, J.; Sanchez, T.; Kuzay, T.M.

    1992-01-01

    The advent of third generation synchrotron radiation sources, like the Advanced Photon Source (APS), will provide significant increases in brilliance over existing synchrotron sources. The APS x-ray undulators will increase the brilliance in the 3-40 KeV range by several orders of magnitude. Thus, the design of the photon beam position monitor is a challenging engineering task. The beam position monitors must withstand the high thermal load, be able to achieve sub-micron spatial resolution while maintaining their stability, and be compatible with both undulators and wigglers. A preliminary APS prototype photon beam position monitor consisting of a CVD-diamond-based, tungsten-coated blade was tested on the APS/CHESS undulator at the Cornell High Energy Synchrotron Radiation Source (CHESS) and on the NSLS X-13 undulator beamline. Results from these tests, as well as the design of this prototype APS photon beam position monitor, will be discussed in this paper

  7. The APS X-ray undulator photon beam position monitor and tests at CHESS and NSLS

    International Nuclear Information System (INIS)

    Shu, D.; Rodricks, B.; Barraza, J.; Sanchez, T.; Kuzay, T.M.

    1992-01-01

    The advent of thirs generation synchrotron sources, like the Advanced Photon Source (APS), will provide significant increases in brilliance over existing synchrotron sources. The APS X-ray undulators will increase the brilliance in the 3-40 keV range by several orders of magnitude. Thus, the design of the photon beam position monitor is a challenging engineering task. The beam position monitors must withstand the high thermal load, be able to achieve submicron spatial resolution while maintaining their stability, and be compatible with both undulators and wigglers. A preliminary APS prototype photon beam position monitor consisting of a CVD-diamond-based, tungsten-coated blade was tested on the APS/CHESS undulator at the Cornell High Energy Synchrotron Radiation Source (CHESS) and on the NSLS X-13 undulator beamline. Results from these tests, as well as the design of this prototype APS photon beam position monitor, will be discussed in this paper. (orig.)

  8. Automated Procurement System (APS): Project management plan (DS-03), version 1.2

    Science.gov (United States)

    Murphy, Diane R.

    1994-01-01

    The National Aeronautics and Space Administration (NASA) Marshall Space Flight Center (MSFC) is implementing an Automated Procurement System (APS) to streamline its business activities that are used to procure goods and services. This Project Management Plan (PMP) is the governing document throughout the implementation process and is identified as the APS Project Management Plan (DS-03). At this point in time, the project plan includes the schedules and tasks necessary to proceed through implementation. Since the basis of APS is an existing COTS system, the implementation process is revised from the standard SDLC. The purpose of the PMP is to provide the framework for the implementation process. It discusses the roles and responsibilities of the NASA project staff, the functions to be performed by the APS Development Contractor (PAI), and the support required of the NASA computer support contractor (CSC). To be successful, these three organizations must work together as a team, working towards the goals established in this Project Plan. The Project Plan includes a description of the proposed system, describes the work to be done, establishes a schedule of deliverables, and discusses the major standards and procedures to be followed.

  9. Estêvão e a Ação Popular (AP: a história da AP nas memórias de Duarte Pereira

    Directory of Open Access Journals (Sweden)

    Reginaldo Benedito Dias

    2016-10-01

    Full Text Available O objetivo deste artigo é analisar como a trajetória da Ação Popular (AP, organização de esquerda das décadas de 1960 e 1970, é narrada e interpretada por Duarte Pacheco Pereira, um dos mais importantes dirigentes de sua história. Caracterizada por sua origem heterodoxa, influenciada pelo humanismo cristão, pelo existencialismo e pelo marxismo, a AP estabeleceu, na conjuntura posterior a 1964, um processo de ruptura com seu passado e de adesão à tradição do marxismo-leninismo, que foi permeado por tensões e cisões políticas. Investigando a interface entre as suas memórias e a história da AP, procura-se aferir sua contribuição à interpretação da singular práxis dessa organização política. A análise tem o suporte de entrevistas concedidas por Duarte Pacheco Pereira, de uma palestra que ele proferiu e do fundo documental que leva seu nome, disponível no Arquivo Edgard Leuenroth.

  10. Prediction of three-dimensional femoral offset from AP pelvis radiographs in primary hip osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Merle, C., E-mail: christian.merle@med.uni-heidelberg.de [Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford (United Kingdom); Department of Orthopaedic and Trauma Surgery, University Hospital Heidelberg (Germany); Waldstein, W., E-mail: wwaldstein@gmail.com [Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford (United Kingdom); Department of Orthopaedic and Trauma Surgery, University Hospital Heidelberg (Germany); Pegg, E.C., E-mail: elise.pegg@ndorms.ox.ac.uk [Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford (United Kingdom); Streit, M.R., E-mail: marcus.streit@med.uni-heidelberg.de [Department of Orthopaedic and Trauma Surgery, University Hospital Heidelberg (Germany); Gotterbarm, T., E-mail: tobias.gotterbarm@med.uni-heidelberg.de [Department of Orthopaedic and Trauma Surgery, University Hospital Heidelberg (Germany); Aldinger, P.R., E-mail: peter.aldinger@diak-stuttgart.de [Department of Orthopaedic Surgery, Paulinenhilfe, Diakonieklinikum, Stuttgart (Germany); Murray, D.W., E-mail: david.murray@ndorms.ox.ac.uk [Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford (United Kingdom); Gill, H.S., E-mail: r.gill@bath.ac.uk [Department of Mechanical Engineering, University of Bath (United Kingdom)

    2013-08-15

    Background: In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the accuracy and reliability of predicting three-dimensional (3-D) FO from standardised AP pelvis radiographs. Methods: In a retrospective cohort study, pre-operative AP pelvis radiographs, AP hip radiographs and CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40–79) years, mean body-mass-index 27 (range: 19–57) kg/m{sup 2}) with primary end-stage hip OA were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding radiographs and CT scans. Measurement reliability was evaluated using intra-class-correlation-coefficients. To predict 3-D FO from AP pelvis measurements and to assess the accuracy compared to CT, the entire cohort was randomly split into subgroups A and B. Gender specific regression equations were derived from group A (245 patients) and the accuracy of prediction was evaluated in group B (100 patients) using Bland–Altman plots. Results: In the entire cohort, mean FO was 39.2 mm (95%CI: 38.5–40.0 mm) on AP pelvis radiographs, 44.1 mm (95%CI: 43.4–44.9 mm) on AP hip radiographs and 44.6 mm (95%CI: 44.0–45.2 mm) on CT scans. In group B, we observed no significant difference between gender specific predicted FO (males: 48.0 mm, 95%CI: 47.1–48.8 mm; females: 42.0 mm, 95%CI: 41.1–42.8 mm) and FO as measured on CT (males: 47.7 mm, 95%CI: 46.1–49.4 mm, p = 0.689; females: 41.6 mm, 95%CI: 40.3–43.0 mm, p = 0.607). Conclusions: The present study suggests that FO can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis

  11. A glossary of terms for understanding political aspects in the implementation of Health in All Policies (HiAP).

    Science.gov (United States)

    Oneka, Goldameir; Vahid Shahidi, Faraz; Muntaner, Carles; Bayoumi, Ahmed M; Mahabir, Deb Finn; Freiler, Alix; O'Campo, Patricia; Shankardass, Ketan

    2017-08-01

    Health in All Policies (HiAP) is a strategy that seeks to integrate health considerations into the development, implementation and evaluation of policies across various non-health sectors of the government. Over the past 15 years, there has been an increase in the uptake of HiAP by local, regional and national governments. Despite the growing popularity of this approach, most existing literature on HiAP implementation remains descriptive rather than explanatory in its orientation. Moreover, prior research has focused on the more technical aspects of the implementation process. Thus, studies that aim to 'build capacity to promote, implement and evaluate HiAP' abound. Conversely, there is little emphasis on the political aspects of HiAP implementation. Neglecting the role of politics in shaping the use of HiAP is problematic, since health and the strategies by which it is promoted are partially political.This glossary addresses the politics gap in the existing literature by drawing on theoretical concepts from political, policy, and public health sciences to articulate a framework for studying how political mechanisms influence HiAP implementation. To this end, the glossary forms part of an on-going multiple explanatory case study of HiAP implementation, HARMONICS (HiAP Analysis using Realist Methods on International Case Studies, harmonics-hiap.ca), and is meant to expand on a previously published glossary addressing the topic of HiAP implementation more broadly. Collectively, these glossaries offer a conceptual toolkit for understanding how politics explains implementation outcomes of HiAP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. AP-Cloud: Adaptive Particle-in-Cloud method for optimal solutions to Vlasov–Poisson equation

    International Nuclear Information System (INIS)

    Wang, Xingyu; Samulyak, Roman; Jiao, Xiangmin; Yu, Kwangmin

    2016-01-01

    We propose a new adaptive Particle-in-Cloud (AP-Cloud) method for obtaining optimal numerical solutions to the Vlasov–Poisson equation. Unlike the traditional particle-in-cell (PIC) method, which is commonly used for solving this problem, the AP-Cloud adaptively selects computational nodes or particles to deliver higher accuracy and efficiency when the particle distribution is highly non-uniform. Unlike other adaptive techniques for PIC, our method balances the errors in PDE discretization and Monte Carlo integration, and discretizes the differential operators using a generalized finite difference (GFD) method based on a weighted least square formulation. As a result, AP-Cloud is independent of the geometric shapes of computational domains and is free of artificial parameters. Efficient and robust implementation is achieved through an octree data structure with 2:1 balance. We analyze the accuracy and convergence order of AP-Cloud theoretically, and verify the method using an electrostatic problem of a particle beam with halo. Simulation results show that the AP-Cloud method is substantially more accurate and faster than the traditional PIC, and it is free of artificial forces that are typical for some adaptive PIC techniques.

  13. Clustered DNA lesions containing 5-formyluracil and AP site: repair via the BER system.

    Directory of Open Access Journals (Sweden)

    Ekaterina A Belousova

    Full Text Available Lesions in the DNA arise under ionizing irradiation conditions or various chemical oxidants as a single damage or as part of a multiply damaged site within 1-2 helical turns (clustered lesion. Here, we explored the repair opportunity of the apurinic/apyrimidinic site (AP site composed of the clustered lesion with 5-formyluracil (5-foU by the base excision repair (BER proteins. We found, that if the AP site is shifted relative to the 5-foU of the opposite strand, it could be repaired primarily via the short-patch BER pathway. In this case, the cleavage efficiency of the AP site-containing DNA strand catalyzed by human apurinic/apyrimidinic endonuclease 1 (hAPE1 decreased under AP site excursion to the 3'-side relative to the lesion in the other DNA strand. DNA synthesis catalyzed by DNA polymerase lambda was more accurate in comparison to the one catalyzed by DNA polymerase beta. If the AP site was located exactly opposite 5-foU it was expected to switch the repair to the long-patch BER pathway. In this situation, human processivity factor hPCNA stimulates the process.

  14. Comparative incidence of pregnancy outcomes in treated obstetric antiphospholipid syndrome: the NOH-APS observational study.

    Science.gov (United States)

    Bouvier, Sylvie; Cochery-Nouvellon, Eva; Lavigne-Lissalde, Géraldine; Mercier, Erick; Marchetti, Tess; Balducchi, Jean-Pierre; Marès, Pierre; Gris, Jean-Christophe

    2014-01-16

    The incidence of pregnancy outcomes for women with the purely obstetric form of antiphospholipid syndrome (APS) treated with prophylactic low-molecular-weight heparin (LMWH) plus low-dose aspirin (LDA) has not been documented. We observed women without a history of thrombosis who had experienced 3 consecutive spontaneous abortions before the 10th week of gestation or 1 fetal loss at or beyond the 10th week. We compared the frequencies of complications during new pregnancies between treated women with APS (n = 513; LMWH + LDA) and women negative for antiphospholipid antibodies as controls (n = 791; no treatment). Among APS women, prior fetal loss was a risk factor for fetal loss, preeclampsia (PE), premature birth, and the occurrence of any placenta-mediated complication. Being positive for anticardiolipin immunoglobulin M antibodies was a risk factor for any placenta-mediated complication. Among women with a history of recurrent abortion, APS women were at a higher risk than other women of PE, placenta-mediated complications, and neonatal mortality. Among women with prior fetal loss, LMWH + LDA-treated APS women had lower pregnancy loss rates but higher PE rates than other women. Improved therapies, in particular better prophylaxis of late pregnancy complications, are urgently needed for obstetric APS and should be evaluated according to the type of pregnancy loss.

  15. The impact of innovation and organizational factors on APS adoption: Evidence from the Dutch discrete parts industry

    NARCIS (Netherlands)

    A.P. van Hezewijk (Bart); M.F. van Assen (Marcel); S.L. van de Velde (Steef)

    2003-01-01

    textabstractAdvanced Planning and Scheduling (APS) systems have gained renewed interest from academics and practitioners. However, literature on APS adoption is scant. This study explores the impact of organizational and innovation related factors on the adoption of APS systems from a factors

  16. The Demographic Wave: Rethinking Hispanic AP Trends

    Science.gov (United States)

    Edwards, Kelcey; Sawtell, Ellen

    2013-01-01

    Presented at the Advanced Placement Annual Conference (APAC) in Las Vegas, NV in July 2013. This presentation reviews new research examining the AP® experience of Hispanic graduates over the past decade. Topics include an in-depth look at the AP Spanish Language and Culture gateway hypothesis and trends in family characteristics such as parent…

  17. AP1000R pressurised water reactor project in china advances toward completion

    International Nuclear Information System (INIS)

    Harrop, G.

    2014-01-01

    The AP1000 R pressurised water reactor (PWR) project in China is the first deployment of its first-of-a-kind Generation III+ technology, making it one of most internationally important and industry-significant new build projects. The innovative AP1000 PWR design contains advanced passive safety and performance features that involve fewer active safety components than a traditional plant, thereby reducing the site footprint. The AP1000 reactor is the first and only Generation III+ nuclear power plant to be granted design certification by the United States Nuclear Regulatory Commission, and it has received an Interim Design Acceptance Confirmation from the Office for Nuclear Regulation and an Interim Statement of Design Acceptability from the Environment Agency in the United Kingdom. Construction and testing of dual AP1000 PWR units is currently in progress in each of two coastal sites in the People's Republic of China: Sanmen (Zhejiang Province) and Haiyang (Shandong Province). Since the initial contract award in 2007, the Westinghouse Consortium has worked in concert with the owners to construct the plants using innovative structural and mechanical modules. Uniquely designed plant components and essential instrumentation and control systems have been manufactured, delivered, and installed at the plants. Numerous personnel, including future reactor operators, have been trained at both the Sanmen and Haiyang sites, and technology transfer of technical documents and computer codes is well underway. The commercial operation dates are now nearing for Sanmen Unit 1 and Haiyang Unit 1, the first two units scheduled for completion. Consequently, these units are now in advanced stages of completion and present activities include planning and preparation for pre-operational testing, system turnover, and commissioning leading to fuel load, and eventual commercial operation. These activities are pioneering, in that they have never before been performed for a new build of

  18. Avaliação de morfologia e histologia endometrial de mulheres após a menopausa Assessment of endometrial morphology and histology in postmenopausal women

    Directory of Open Access Journals (Sweden)

    Luis Paulo Galvao Wolff

    2010-01-01

    Full Text Available OBJETIVO: Avaliar ambulatorialmente a morfologia e histologia endometrial de mulheres sem sangramento genital após a menopausa. MÉTODOS: Em estudo descritivo foram selecionadas 52 mulheres, após a menopausa, entre 50 e 60 anos, sem terapia hormonal nos últimos seis meses. Todas foram submetidas a exame ultrassonográfico, histeroscópico e biópsias endometriais. RESULTADOS: Das 52 mulheres selecionadas 32 (61,5% apresentaram ultrassonografia normal, cavidade uterina normal com endométrio atrófico à histeroscopia, confirmada pela biópsia endometrial. Vinte (38,4% apresentaram achados histeroscópicos ou histológicos anormais, sendo que apenas cinco destas mostraram endométrio com espessura superior a cinco milímetros ao ultrassom. CONCLUSÃO: A histeroscopia diagnóstica associada à biópsia aspirativa (Pipelle pode evidenciar alterações não observadas ao ultrassom transvaginal.OBJECTIVE: Evaluate in outpatients , the endometrial morphology and histology of non- bleeding postmenopausal women. METHODS: We conducted a descriptive study where 52 menopausal women were selected, between 50 and 60 years of age, who had not used hormone replacement therapy in the last six months and did not present any kind of vaginal bleeding after menopause. These women underwent ultrasound examination, hysteroscopy and biopsy, and then endometrial findings were analyzed. RESULTS: Of the 52 women selected, thirty two (61,5% had normal ultrasound, normal uterine cavity with atrophic endometrium, hysteroscopy, confirmed by endometrial biopsy. Twenty (38,4% had hysteroscopuc and histologic alterations and only five women showed by ultrasound an endometrial thickness of more than five millimeters. CONCLUSION: Diagnostic Hysteroscopy associated with aspiration biopsy (Pipelle performed in the day care facility can reveal endometrial alterations that cannot be diagnosed by transvaginal ultrasound.

  19. Molecular characterization of the 30-AA N-terminal mineral interaction domain of the biomineralization protein AP7.

    Science.gov (United States)

    Kim, Il Won; Morse, Daniel E; Evans, John Spencer

    2004-12-21

    The AP7 protein is one of several mollusk shell proteins which are responsible for aragonite polymorph formation and stabilization within the nacre layer of the Pacific red abalone, H. rufescens. Previously, we demonstrated that the 30-AA N-terminal domain of AP7, denoted as AP7-1, exists as an unfolded sequence and possesses the capability of inhibiting calcium carbonate crystal growth in vitro via growth step frustration or interruption. However, very little is known with regard to the interactive capabilities of this sequence with Ca(II) and with calcium carbonates. Using multidisciplinary techniques, we determine that the AP7-1 polypeptide interacts with Ca(II) ions at the -DD- sequence clusters, yet retains its unfolded, conformationally labile structure in the presence of Ca(II) ions. Further, NMR experiments reveal that the extended structured sequence blocks, -GNGM-, -SVRTQG-, and -ISYL, exhibit motional, chemical exchange, and/or backbone geometry perturbations in response to Ca(II) interactions with AP7-1. Solid-state NMR magic angle spinning studies verify that during the course of in vitro calcium carbonate crystal growth, AP7-1 becomes bound to calcite fragments and cannot be entirely displaced from the mineral fragments using competitive Ca(II) washing. Finally, using a scrambled sequence version of the AP7-1 polypeptide, we observe that sequence scrambling does not adversely affect the crystal growth inhibitory activity of AP7-1, suggesting that the amino acid composition of AP7-1 may be more critical to growth step inhibition than the linear ordering of amino acids.

  20. Report on the value engineering workshop on APS beamline front ends

    International Nuclear Information System (INIS)

    Kuzay, T.

    1993-01-01

    A formal value engineering evaluation process was developed to address the front end components of the beamlines for the Advanced Photon Source (APS). This process (described in Section 2) involved an information phase, a creative phase, a judgment phase, a development phase, and a recommendation phase. Technical experts from other national laboratories and industry were invited to a two-day Value Engineering Workshop on November 5-6, 1992. The results of this Workshop are described in Section 4. Following the Workshop, various actions by the APS staff led to the redesign of the front end components, which are presented in Sections 5 and 6. The cost benefit analysis is presented in Section 7. It is important of realize that an added benefit of the Workshop was to obtain numerous design evaluations and enhancements of the front end components by experts in the field. As the design work proceeds to Title II completion, the APS staff is including many of these suggestions

  1. Analysis of an AP600 intermediate-size loss-of-coolant accident

    Energy Technology Data Exchange (ETDEWEB)

    Boyack, B.E.; Lime, J.F. [Los Alamos National Lab., NM (United States)

    1995-09-01

    A postulated double-ended guillotine break of an AP600 direct-vessel-injection line has been analyzed. This event is characterized as an intermediate-break loss-of-coolant accident. Most of the insights regarding the response of the AP600 safety systems to the postulated accident are derived from calculations preformed with the TRAC-PF1/MOD2 code. However, complementary insights derived from a scaled experiment conducted in the ROSA facility, as well as insights based upon calculations by other codes, are also presented. Based upon the calculated and experimental results, the AP600 will not experience a core heat up and will reach a safe shutdown state using only safety-class equipment. Only the early part of the long-term cooling period initiated by In-containment Refueling Water Storage Tank injection was evaluated. Thus, the observation that the core is continuously cooled should be verified for the later phase of the long-term cooling period when sump injection and containment cooling processes are important.

  2. A Knockout Screen of ApiAP2 Genes Reveals Networks of Interacting Transcriptional Regulators Controlling the Plasmodium Life Cycle.

    Science.gov (United States)

    Modrzynska, Katarzyna; Pfander, Claudia; Chappell, Lia; Yu, Lu; Suarez, Catherine; Dundas, Kirsten; Gomes, Ana Rita; Goulding, David; Rayner, Julian C; Choudhary, Jyoti; Billker, Oliver

    2017-01-11

    A family of apicomplexa-specific proteins containing AP2 DNA-binding domains (ApiAP2s) was identified in malaria parasites. This family includes sequence-specific transcription factors that are key regulators of development. However, functions for the majority of ApiAP2 genes remain unknown. Here, a systematic knockout screen in Plasmodium berghei identified ten ApiAP2 genes that were essential for mosquito transmission: four were critical for the formation of infectious ookinetes, and three were required for sporogony. We describe non-essential functions for AP2-O and AP2-SP proteins in blood stages, and identify AP2-G2 as a repressor active in both asexual and sexual stages. Comparative transcriptomics across mutants and developmental stages revealed clusters of co-regulated genes with shared cis promoter elements, whose expression can be controlled positively or negatively by different ApiAP2 factors. We propose that stage-specific interactions between ApiAP2 proteins on partly overlapping sets of target genes generate the complex transcriptional network that controls the Plasmodium life cycle. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  3. The Freshman Nine: Helping High School Freshmen Be Successful in AP Human Geography

    Science.gov (United States)

    Garner, Jennifer

    2012-01-01

    Teaching AP Human Geography to freshmen seems like a daunting task and while there are many arguments both for and against offering the course to freshmen, for many teachers it is reality. In this article, the author offers nine tips to help high school freshmen be successful in the course and on the AP exam.

  4. Promotion of Homologous Recombination and Genomic Stability byRAD51AP1 via RAD51 Recombinase Enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Wiese, Claudia; Dray, Eloise; Groesser, Torsten; San Filippo,Joseph; Shi, Idina; Collins, David W.; Tsai, Miaw-Sheue; Williams,Gareth; Rydberg, Bjorn; Sung, Patrick; Schild, David

    2007-04-11

    Homologous recombination (HR) repairs chromosome damage and is indispensable for tumor suppression in humans. RAD51 mediates the DNA strand pairing step in HR. RAD51AP1 (RAD51 Associated Protein 1) is a RAD51-interacting protein whose function has remained elusive. Knockdown of RAD51AP1 in human cells by RNA interference engenders sensitivity to different types of genotoxic stress. Moreover, RAD51AP1-depleted cells are impaired for the recombinational repair of a DNA double-strand break and exhibit chromatid breaks both spontaneously and upon DNA damaging treatment. Purified RAD51AP1 binds dsDNA and RAD51, and it greatly stimulates the RAD51-mediated D-loop reaction. Biochemical and cytological results show that RAD51AP1 functions at a step subsequent to the assembly of the RAD51-ssDNA nucleoprotein filament. Our findings provide the first evidence that RAD51AP1 helps maintain genomic integrity via RAD51 recombinase enhancement.

  5. Analysis of risk management during AP1000 equipment technology transfer and localization

    International Nuclear Information System (INIS)

    Gao Yongjun; Guan Rui

    2009-01-01

    This article analyzes the risk factors existing in AP1000 equipment technology transfer and localization process by describing the invitation for bid, tender evaluation and contract negotiation process of the third-generation nuclear power plant technology introduction project of China and discusses the classification, evaluation and analysis methods of risks, and puts forward some referential suggestions for the successful introduction of equipment technology for AP1000 nuclear project. (authors)

  6. Size response of an SMPS-APS system to commercial multi-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Lee, Seung-Bok; Lee, Jun-Hyun; Bae, Gwi-Nam

    2010-01-01

    Carbon nanotubes (CNTs) are representative-engineered nanomaterials with unique properties. The safe production of CNTs urgently requires reliable tools to assess inhalation exposure. In this study, on-line aerosol instruments were employed to detect the release of multi-walled CNTs (MWCNTs) in workplace environments. The size responses of aerosol instruments consisting of both a scanning mobility particle sizer (SMPS) and an aerodynamic particle sizer (APS) were examined using five types of commercial MWCNTs. A MWCNT solution and powder were aerosolized using atomizing and shaking methods, respectively. Regardless of the phase and purity, the aerosolized MWCNTs showed consistent size distributions with both SMPS and APS. The SMPS and APS measurements revealed a dominant broad peak at approximately 200-400 nm and a distinct narrow peak at approximately 2 μm, respectively. Comparing with field application of the two aerosol instruments, the APS response could be a fingerprint of the MWCNTs in a real workplace environment. A modification of the atomizing method is recommended for the long-term inhalation toxicity studies.

  7. Sonographic Measurement of AP Diameter and Wall Thickness of the Gallbladder

    International Nuclear Information System (INIS)

    Chung, S.K.; Lee, J. S.; Huh, S. J.; Baek, I. S.

    1982-01-01

    Call bladder size and wall thickness are important in the assessment of the pathologic condition. Authors have measured AP diameter of gallbladder and evaluated the change of all thickness between fasting and postprandial state. The results were as follows: 1. The mean of AP diameter was 2.18+0.49cm 2. The wall thickness was 2.7+0.6mm in fasting state and 3.3+0.8mm after meal. 3. The increase of wall thickness after fat meal was significant statistically(p<.001)

  8. APS-Workshop on Characterization of MMIC (Monolithic Microwave Integrated Circuit) Devices for Array Antenna

    Science.gov (United States)

    Smetana, Jerry (Editor); Mittra, Raj (Editor); Laprade, Nick; Edward, Bryan; Zaghloul, Amir

    1987-01-01

    The IEEE AP-S ADCOM is attempting to expand its educational, tutorial and information exchange activities as a further benefit to all members. To this end, ADCOM will be forming specialized workshops on topics of interest to its members. The first such workshop on Characterization and Packaging of MMIC Devices for Array Antennas was conceived. The workshop took place on June 13, 1986 as part of the 1986 International Symposium sponsored by IEEE AP-S and URSI in Philadelphia, PA, June 9-13, 1986. The workshop was formed to foster the interchange of ideas among MMIC device users and to provide a forum to collect and focus information among engineers experienced and interested in the topic. After brief presentations by the panelists and comments from attendees on several subtopics, the group was divided into working committees. Each committee evaluated and made recommendations on one of the subtopics.

  9. Functions and Application of the AP2/ERF Transcription Factor Family in Crop Improvement

    Institute of Scientific and Technical Information of China (English)

    Zhao-Shi Xu; Ming Chen; Lian-Cheng Li; You-Zhi Ma

    2011-01-01

    Plants have acquired sophisticated stress response systems to adapt to changing environments. It is important to understand plants' stress response mechanisms in the effort to improve crop productivity under stressful conditions. The AP2/ERF transcription factors are known to regulate diverse processes of plant development and stress responses.In this study, the molecular characteristics and biological functions of AP2/ERFs in a variety of plant species were analyzed. AP2/ERFs,especially those in DREB and ERF subfamilies, are ideal candidates for crop improvement because their overexpression enhances tolerances to drought, salt, freezing, as well as resistances to multiple diseases in the transgenic plants. The comprehensive analysis of physiological functions is useful in elucidating the biological roles of AP2/ERF family genes in gene interaction, pathway regulation, and defense response under stress environments, which should provide new opportunities for the crop tolerance engineering.

  10. Lumbar pedicle screw placement: Using only AP plane imaging

    Directory of Open Access Journals (Sweden)

    Anil Sethi

    2012-01-01

    Conclusion: Placement of pedicle screws under fluoroscopic guidance using AP plane imaging alone with tactile guidance is safe, fast, and reliable. However, a good understanding of the radiographic landmarks is a prerequisite.

  11. Experimental Evaluation of Unicast and Multicast CoAP Group Communication

    Directory of Open Access Journals (Sweden)

    Isam Ishaq

    2016-07-01

    Full Text Available The Internet of Things (IoT is expanding rapidly to new domains in which embedded devices play a key role and gradually outnumber traditionally-connected devices. These devices are often constrained in their resources and are thus unable to run standard Internet protocols. The Constrained Application Protocol (CoAP is a new alternative standard protocol that implements the same principals as the Hypertext Transfer Protocol (HTTP, but is tailored towards constrained devices. In many IoT application domains, devices need to be addressed in groups in addition to being addressable individually. Two main approaches are currently being proposed in the IoT community for CoAP-based group communication. The main difference between the two approaches lies in the underlying communication type: multicast versus unicast. In this article, we experimentally evaluate those two approaches using two wireless sensor testbeds and under different test conditions. We highlight the pros and cons of each of them and propose combining these approaches in a hybrid solution to better suit certain use case requirements. Additionally, we provide a solution for multicast-based group membership management using CoAP.

  12. Effect of the Dispersibility of Nano-CuO Catalyst on Heat Releasing of AP/HTPB Propellant

    International Nuclear Information System (INIS)

    Yang, Y.; Yu, X.; Wang, J.; Wang, Y.

    2011-01-01

    Kneading time is adjusted to change the dispersibility of nano-CuO in AP/HTPB (Ammonia Perchlorate/Hydroxyl-Terminated Polybutadiene) composite propellants. Nano-CuO/AP is prepared to serve as the other dispersing method of nano-CuO, named pre dispersing procedure. Several kinds of heat releasing, thermal decomposition by DSC, combustion heat in oxygen environment, and explosion heat in nitrogen environment, are characterized to learn the effect of dispersibility of nano-CuO catalyst on heat releasing of propellants. With pre-dispersing procedures, thermal decomposition temperature of nano-CuO/AP and its propellant are about 25 degree C and 8.6 degree C lower than that of AP simple mixed with nano-CuO and its propellant, respectively. Comparing propellant with simple mixed nano-CuO kneading 3 hours, combustion heat and explosion heat of propellant with nano-CuO/AP increase about 1.4% and 1.7%, respectively. However, because of the breaking of nano-CuO/AP structure during kneading procedure, combustion heat and explosion heat of all the samples are decreased with the increase of kneading time after 3 hours.

  13. Andrographolide suppresses high glucose-induced fibronectin expression in mesangial cells via inhibiting the AP-1 pathway.

    Science.gov (United States)

    Lan, Tian; Wu, Teng; Gou, Hongju; Zhang, Qianqian; Li, Jiangchao; Qi, Cuiling; He, Xiaodong; Wu, Pingxiang; Wang, Lijing

    2013-11-01

    Mesangial cells (MCs) proliferation and accumulation of glomerular matrix proteins such as fibronectin (FN) are the early features of diabetic nephropathy, with MCs known to upregulate matrix protein synthesis in response to high glucose. Recently, it has been found that andrographolide has renoprotective effects on diabetic nephropathy. However, the molecular mechanism underlying these effects remains unclear. Cell viability and proliferation was evaluated by MTT. FN expression was examined by immunofluorescence and immunoblotting. Activator protein-1 (AP-1) activation was assessed by immunoblotting, luciferase reporter and electrophoretic mobility shift assays. Andrographolide significantly decreased high glucose-induced cell proliferation and FN expression in MCs. Exposure of MCs to high glucose markedly stimulated the expression of phosphorylated c-jun, whereas the stimulation was inhibited by andrographolide. Plasmid pAP-1-Luc luciferase reporter assay showed that andrographolide blocked high glucose-induced AP-1 transcriptional activity. EMSA assay demonstrated that increased AP-1 binding to an AP-1 binding site at -1,029 in the FN gene promoter upon high glucose stimulation, and the binding were disrupted by andrographolide treatment. These data indicate that andrographolide suppresses high glucose-induced FN expression by inhibiting AP-1-mediated pathway. © 2013 Wiley Periodicals, Inc.

  14. AntiPhospholipid Syndrome Alliance for Clinical Trials and InternatiOnal Networking (APS ACTION): 5-Year Update.

    Science.gov (United States)

    Barbhaiya, Medha; Andrade, Danieli; Erkan, Doruk

    2016-10-01

    Antiphospholipid Syndrome Alliance for Clinical Trials and International Networking (APS ACTION) is the first-ever international network created to design and conduct large-scale, multicenter clinical trials and research in persistently antiphospholipid antibody (aPL)-positive patients. Since its inception in 2010, the APS ACTION has made important strides toward our goal of international research collaboration and data sharing. Through the dedication and hard work of 50 APS ACTION members, collaborative international projects are currently underway including a multicenter web-based registry and repository of aPL-positive patients, a randomized controlled clinical trial assessing the efficacy of hydroxychloroquine for primary thrombosis prevention in persistently aPL-positive but thrombosis-free patients, standardization of aPL testing through the use of core laboratories worldwide, identification of the limitations in the existing aPL/APS literature, and conducting observational research studies to further our understanding of the disease. Thus far, APS ACTION has held annual workshops and summits with the aim of facilitating international collaboration and developing initiatives to recruit young scholars to APS research. This paper describes updates related to the organization's structure, ongoing research efforts, and recent accomplishments and discusses future directions.

  15. Updating AP Potential™ Expectancy Tables Involving PSAT/NMSQT® Writing. Research Notes. RN-35

    Science.gov (United States)

    Ewing, Maureen; Camara, Wayne J.; Millsap, Roger E.; Milewski, Glenn B.

    2007-01-01

    AP Potential™ is a data-driven tool offered by the College Board that uses scores from the PSAT/NMSQT® to identify students who have the potential to succeed in Advanced Placement Program® (AP®) courses (College Board, 2007). Research showing a moderate-to-strong correlation between PSAT/NMSQT scores and AP Exam scores serves as the basis for this…

  16. Analisis Gerakan Tendangan Ap Chagi Pada Taekwondoin junior Putra Kabupaten lombok Timur

    Directory of Open Access Journals (Sweden)

    Nopi Hariadi

    2016-10-01

    Full Text Available Tendangan Ap Chagi ini merupakan teknik tendangan yang paling mendasar yang harus dikuasai Taekwondoin dan dapat menghasilkan poin tiga. (WTF Competition Rules & Interpretation, 2012: 22. Jenis penelitian yaitu jenis penelitian deskriptif kuantitatif dan bila ditinjau dari jenis pendekatannya termasuk Action Research (Penelitian tindakan. Instrumen penelitian dalam penelitian ini menggunakan Software Dartfish Handycam dan Laptop. Analisis data menggunakan Analyzer pada Software Dartfish serta penilaan dari Expert Judgement yang meliputi sudut tangan, sudut kemiringan punggung, sudut bukaan kaki dan sudut putaran telapak kaki, serta kecepatan dan ketepatan tendangan. Dari 3 atlet yang menjadi subjek penelitian diperoleh satu atlet yang mendapatkan hasil terbaik, pada tendangan Ap Chagi, hasil terbaik diperoleh pada subjek penelitian AKB. Penelitian menyimpulkan perbaikan gerakan berupa pendampingan dan arahan dari peneliti, pelatih dan Expert Judgement, berupa latihan fisik dan latihan teknik dasar tendangan Ap Chagi. Dan hasil tendangan Ap Chagi yang paling baik atau efektif terdapat pada refleksi III, dapat dilihat pada Taekwondoin AKB dengan waktu 0,34 s, jarak tendangan dengan sasaran 1,60 m, sehingga menghasilkan kecepatan 5,0 m/s. Berikutnya untuk sudut tangan 51.3°, sudut kemiringan punggung 141,8°, sudut bukaan kaki sebesar 101,0°, sudut putaran telapak kaki sebesar 50,0° dan tepat pada sasaran yang telah ditentukan.

  17. Paediatric Wandering Spleens in Malawi

    African Journals Online (AJOL)

    by a double layer of peritoneum. The wandering spleen is the rare description of an abnormally positioned spleen, which is thought to occur due to laxity, abnormality or absence of the aforementioned ligaments. The wandering spleen is noted to have a longer than normal pedicle, and because of its intraperitoneal location, ...

  18. Role of the ubiquitin ligase E6AP/UBE3A in controlling levels of the synaptic protein Arc

    Science.gov (United States)

    Kühnle, Simone; Mothes, Benedikt; Matentzoglu, Konstantin; Scheffner, Martin

    2013-01-01

    Inactivation of the ubiquitin ligase E6 associated protein (E6AP) encoded by the UBE3A gene has been associated with development of the Angelman syndrome. Recently, it was reported that in mice, loss of E6AP expression results in increased levels of the synaptic protein Arc and a concomitant impaired synaptic function, providing an explanation for some phenotypic features of Angelman syndrome patients. Accordingly, E6AP has been shown to negatively regulate activity-regulated cytoskeleton-associated protein (Arc) and it has been suggested that E6AP targets Arc for ubiquitination and degradation. In our study, we provide evidence that Arc is not a direct substrate for E6AP and binds only weakly to E6AP, if at all. Furthermore, we show that down-regulation of E6AP expression stimulates estradiol-induced transcription of the Arc gene. Thus, we propose that Arc protein levels are controlled by E6AP at the transcriptional rather than at the posttranslational level. PMID:23671107

  19. Apixaban for the Secondary Prevention of Thrombosis Among Patients With Antiphospholipid Syndrome: Study Rationale and Design (ASTRO-APS).

    Science.gov (United States)

    Woller, Scott C; Stevens, Scott M; Kaplan, David A; Branch, D Ware; Aston, Valerie T; Wilson, Emily L; Gallo, Heather M; Johnson, Eric G; Rondina, Matthew T; Lloyd, James F; Evans, R Scott; Elliott, C Gregory

    2016-04-01

    Antiphospholipid syndrome (APS) is an acquired thrombophilia characterized by thrombosis, pregnancy morbidity, and the presence of characteristic antibodies. Current therapy for patients having APS with a history of thrombosis necessitates anticoagulation with the vitamin K antagonist warfarin, a challenging drug to manage. Apixaban, approved for the treatment and prevention of venous thrombosis with a low rate of bleeding observed, has never been studied among patients with APS. We report study rationale and design of Apixaban for the Secondary Prevention of Thrombosis Among Patients With Antiphospholipid Syndrome (ASTRO-APS), a prospective randomized open-label blinded event pilot study that will randomize patients with a clinical diagnosis of APS receiving therapeutic anticoagulation to either adjusted-dose warfarin or apixaban 2.5 mg twice a day. We aim to report our ability to identify, recruit, randomize, and retain patients with APS randomized to apixaban compared with warfarin. We will report clinically important outcomes of thrombosis and bleeding. All clinical outcomes will be adjudicated by a panel blinded to the treatment arm. A unique aspect of this study is the enrollment of patients with an established clinical diagnosis of APS. Also unique is our use of electronic medical record interrogation techniques to identify patients who would likely meet our inclusion criteria and use of an electronic portal for follow-up visit data capture. ASTRO-APS will be the largest prospective study to date comparing a direct oral anticoagulant with warfarin among patients with APS for the secondary prevention of thrombosis. Our inclusion criteria assure that outcomes obtained will be clinically applicable to the routine management of patients with APS receiving indefinite anticoagulation. © The Author(s) 2015.

  20. Tank 241-AP-103 08/1999 Compatibility Grab Samples, Analytical Results for the Final Report

    International Nuclear Information System (INIS)

    BELL, K.E.

    1999-01-01

    This document is the format IV, final report for the tank 241-AP-103 (AP-103) grab samples taken in August 1999 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank AP-103 samples were performed as directed in ''Compatibility Grub Sampling and Analysis Plan for Fiscal Year 1999'' (Sasaki 1999a). Any deviations from the instructions provided in the tank sampling and analysis plan (TSAP) were discussed in this narrative. No notification limits were exceeded

  1. Efficacy of a new fractional CO2 laser in the treatment of photodamage and acne scarring.

    Science.gov (United States)

    Katz, Bruce

    2010-01-01

    This study evaluates the efficacy and safety of a novel fractional CO(2) laser device for improving facial rhytids, hyperpigmentation, enlarged pores, skin laxity, and acne scarring. Subjects (n= 15) were treated three to five times at 3-week intervals. Biopsy specimens were used to evaluate healing response and neocollagenesis. Clinical improvement was rated on a quartile rating scale from digital photographs. Subject discomfort during treatment was evaluated on a scale of 0 to 5. Fourteen subjects who completed the study achieved good to excellent improvement in overall appearance, with 60% rated excellent. Improvement in photodamage was good to excellent in 92% of subjects, and reduction in rhytids was good to excellent in 85%. A total of 79% of subjects achieved good to excellent improvement in pore sizes and skin laxity. Subject discomfort during treatment was 3.0 +/- 0.7. Erythema persisted for 2-3 days, and subjects resumed normal activities 1-2 days after the procedure. Histological slides after a single treatment showed new collagen formation. The SmartSkin fractional CO(2) system (Cynosure, Inc., Westford, MA, USA) provides significant improvement for the treatment of facial wrinkles, hyperpigmentation, pore size, and skin laxity associated with photodamage.

  2. Analysis of the electrical noise from the APS kicker magnet power supplies

    International Nuclear Information System (INIS)

    Carwardine, J.A.; Wang, J.

    1995-01-01

    The APS kicker magnet power supplies deliver damped sinusoidal currents in excess of 2400A peak with a half-period of 300ns to the kicker magnets. Conducted and radiated electromagnetic interference (EMI) is created by this system in the low megahertz range. This interference affects a number of beam diagnostics in the APS injector. The sources and coupling mechanisms for the EMI generated by this system are described and solutions discussed

  3. APS storage ring vacuum system performance

    International Nuclear Information System (INIS)

    Noonan, J.R.; Gagliano, J.; Goeppner, G.A.

    1997-01-01

    The Advanced Photon Source (APS) storage ring was designed to operated with 7-GeV, 100-mA positron beam with lifetimes > 20 hours. The lifetime is limited by residual gas scattering and Touschek scattering at this time. Photon-stimulated desorption and microwave power in the rf cavities are the main gas loads. Comparison of actual system gas loads and design calculations will be given. In addition, several special features of the storage ring vacuum system will be presented

  4. An Analysis of Media’s Role: Case Study of Army Public School (APS Peshawar Attack

    Directory of Open Access Journals (Sweden)

    Qureshi Rameesha

    2016-12-01

    Full Text Available The study aimed at analyzing the role of media during and after terrorist attacks by examining the media handling of APS Peshawar attack. The sample consisted of males and females selected on convenience basis from universities of Rawalpindi and Islamabad. It was hypothesized that (1 Extensive media coverage of terrorist attacks leads to greater publicity/recognition of terrorist groups (2 Media coverage of APS Peshawar attack increased fear and anxiety in public (3 Positive media handling/coverage of APS Peshawar attack led to public solidarity and peace. The results indicate that i Media coverage of terrorist attacks does help terrorist groups to gain publicity and recognition amongst public ii Media coverage of Aps Peshawar attack did not increase fear/anxiety in fact it directed the Pakistani nation towards public solidarity and peace.

  5. Time Trials--An AP Physics Challenge Lab

    Science.gov (United States)

    Jones, David

    2009-01-01

    I have come to the conclusion that for high school physics classroom and laboratory experiences, simpler is better! In this paper I describe a very simple and effective lab experience that my AP students have thoroughly enjoyed year after year. I call this lab exercise "Time Trials." The experiment is simple in design and it is a lot of fun for…

  6. Transverse impedance measurement using response matrix fit method at APS

    International Nuclear Information System (INIS)

    Sajaev, V.

    2007-01-01

    The Advanced Photon Source (APS) is a third-generation synchrotron light source based on a 7-GeV electron storage ring. In third-generation light sources the synchrotron radiation is mainly produced in undulators. In order to achieve high photon flux and tunability, the magnet gap in undulators has to be as small as possible. Therefore, the undulators are installed on dedicated small-gap insertion device (ID) vacuum chambers. APS has thirty-five 5-m-long straight sections available for undulators. At the time of the measurements, there were 31 straight sections occupied with various insertion devices, and 4 straight sections were still empty. Most of the ID vacuum chambers have a 8-mm in-vacuum gap, and two chambers have a 5-mm gap. These narrow-gap vacuum chambers are believed to be the main source of the transverse impedance of the machine. One can measure the combined impedance by measuring the transverse tune slope with single-bunch current. Comparing this slope before and after installation of the narrow-gap vacuum chamber, one can deduce the impedance of the chamber. It is difficult to accurately measure the change in the tune slope after one or a few new ID chambers are installed. If several identical ID vacuum chambers are installed over a period of time, then one can estimate the contribution of one ID chamber. Over the last few years there have been a number of attempts to measure the impedance of separate components of accelerators. Phase-advance measurements from beam position monitor (BPM) turn-by-turn histories were used at LEP to measure the impedance distribution around the ring. Researches at LEP were able to fit average impedance in the long sections of the LEP arc and determine the impedance of the rf sections. The method was tried at APS; however, the accuracy of the measurements was not enough to determine the small impedance of a single ID vacuum chamber. There is also a different approach that uses local orbit bumps to probe different parts

  7. Recombinant thermostable AP exonuclease from Thermoanaerobacter tengcongensis: cloning, expression, purification, properties and PCR application

    DEFF Research Database (Denmark)

    Dabrowski, Slawomir; Brillowska-Dabrowska, Anna; Ahring, Birgitte Kiær

    2013-01-01

    Apurinic/apyrimidinic (AP) sites in DNA are considered to be highly mutagenic and must be corrected to preserve genetic integrity, especially at high temperatures. The gene encoding a homologue of AP exonuclease was cloned from the thermophilic anaerobic bacterium Thermoanaerobacter tengcongensis......) of fully active and soluble His6-tagged Tte AP enzyme with His6-tag on C-terminal end was obtained in Escherichia coli Rosetta (DE3) pLysS. The active enzyme was purified up to 98% homogeneity in one chromatographic step using metal-affinity chromatography on Ni(2+)-IDA-Sepharose resin. The yield was 90 mg......, pH 8.0 and at low Mg2+ concentration (0.5 mM). Higher Mg2+ concentration (> 1 mM) enhanced 3'-5' exonuclease activity and at Mg2+ concentration > 2.0 mM 3' nuclease activity was observed. Because of the endonuclease activity of Tte AP exonuclease, the enzyme was applied in PCR amplification of long...

  8. AP-IO: asynchronous pipeline I/O for hiding periodic output cost in CFD simulation.

    Science.gov (United States)

    Xiaoguang, Ren; Xinhai, Xu

    2014-01-01

    Computational fluid dynamics (CFD) simulation often needs to periodically output intermediate results to files in the form of snapshots for visualization or restart, which seriously impacts the performance. In this paper, we present asynchronous pipeline I/O (AP-IO) optimization scheme for the periodically snapshot output on the basis of asynchronous I/O and CFD application characteristics. In AP-IO, dedicated background I/O processes or threads are in charge of handling the file write in pipeline mode, therefore the write overhead can be hidden with more calculation than classic asynchronous I/O. We design the framework of AP-IO and implement it in OpenFOAM, providing CFD users with a user-friendly interface. Experimental results on the Tianhe-2 supercomputer demonstrate that AP-IO can achieve a good optimization effect for the periodical snapshot output in CFD application, and the effect is especially better for massively parallel CFD simulations, which can reduce the total execution time up to about 40%.

  9. AP-IO: Asynchronous Pipeline I/O for Hiding Periodic Output Cost in CFD Simulation

    Directory of Open Access Journals (Sweden)

    Ren Xiaoguang

    2014-01-01

    Full Text Available Computational fluid dynamics (CFD simulation often needs to periodically output intermediate results to files in the form of snapshots for visualization or restart, which seriously impacts the performance. In this paper, we present asynchronous pipeline I/O (AP-IO optimization scheme for the periodically snapshot output on the basis of asynchronous I/O and CFD application characteristics. In AP-IO, dedicated background I/O processes or threads are in charge of handling the file write in pipeline mode, therefore the write overhead can be hidden with more calculation than classic asynchronous I/O. We design the framework of AP-IO and implement it in OpenFOAM, providing CFD users with a user-friendly interface. Experimental results on the Tianhe-2 supercomputer demonstrate that AP-IO can achieve a good optimization effect for the periodical snapshot output in CFD application, and the effect is especially better for massively parallel CFD simulations, which can reduce the total execution time up to about 40%.

  10. Application of computerized procedure system for AP1000

    International Nuclear Information System (INIS)

    Wen Fang

    2012-01-01

    With the tendency of digitalisation in instrumentation and control system of nuclear power plants, AP1000, as well as other advanced PWRs, is provided with the technical basis for the application of CPS (computerized procedure system). This paper makes a brief introduction on CPS construction and function. CPS, as an advanced procedure system, does not only have the function of electronic indication for operation procedures, but also have the ability to monitor plant data, process the data and then present the status of the procedure steps to the reactor operator. In addition, advantages of CPS compared with paper-based procedures and comparison with digital operating system of one M310 plus advanced nuclear power plant are described. Moreover, based on current situation, this paper offers several suggestions on CPS localization for Sanmen AP1000 nuclear power project. Besides, the last part of this paper discusses problems we might meet during the process of CPS localization. (author)

  11. Characterization of liquid entrainment in the AP1000 automatic depressurization system from APEX tests

    International Nuclear Information System (INIS)

    Richard F Wright; Terry L Schulz; Jose N Reyes; John Groome

    2005-01-01

    Full text of publication follows: The AP1000 is a 1000 MWe advanced nuclear power plant that uses passive safety features to enhance plant safety and to provide significant and measurable improvements in plant simplification, reliability, investment protection and plant costs. The AP1000 relies heavily on the 600 MWe AP600 which received design certification in 1999. A critical part of the AP600 design certification process involved the testing of the passive safety systems. A one-fourth height, one-fourth pressure test facility, APEX-600, was constructed at the Oregon State University to study design basis events, and to provide a body of data to be used to validate the computer models used to analyze the AP600. This facility was extensively modified to reflect the design changes for AP1000 including higher power in the electrically heated rods representing the reactor core, and changes in the size of the pressurizer, core makeup tanks and automatic depressurization system. The APEX-1000 test facility was used to perform design basis accident simulations and separate effects tests to support the AP1000 design certification process. In the event of a LOCA, the AP1000 passive core cooling system provides sources of core makeup water along with an automatic depressurization system (ADS) consisting of several stages of valves which reduce the reactor coolant system pressure in a controlled manner. The final stage of this system, ADS-4, consists of four large valves that open off the hot legs, reducing the pressure to allow gravity injection from the in-containment refueling water storage tank (IRWST) and eventually the containment sump. The 67% increase in power from AP600 to AP1000 results in proportionally larger steam velocities exiting the core. Higher steam velocities could increases the potential for significant liquid entrainment out the ADS-4 lines, affecting the liquid inventory in the reactor. Tests were performed in APEX-1000 to characterize the two

  12. Application of fault tree methodology to modeling of the AP1000 plant digital reactor protection system

    International Nuclear Information System (INIS)

    Teolis, D.S.; Zarewczynski, S.A.; Detar, H.L.

    2012-01-01

    The reactor trip system (RTS) and engineered safety features actuation system (ESFAS) in nuclear power plants utilizes instrumentation and control (IC) to provide automatic protection against unsafe and improper reactor operation during steady-state and transient power operations. During normal operating conditions, various plant parameters are continuously monitored to assure that the plant is operating in a safe state. In response to deviations of these parameters from pre-determined set points, the protection system will initiate actions required to maintain the reactor in a safe state. These actions may include shutting down the reactor by opening the reactor trip breakers and actuation of safety equipment based on the situation. The RTS and ESFAS are represented in probabilistic risk assessments (PRAs) to reflect the impact of their contribution to core damage frequency (CDF). The reactor protection systems (RPS) in existing nuclear power plants are generally analog based and there is general consensus within the PRA community on fault tree modeling of these systems. In new plants, such as AP1000 plant, the RPS is based on digital technology. Digital systems are more complex combinations of hardware components and software. This combination of complex hardware and software can result in the presence of faults and failure modes unique to a digital RPS. The United States Nuclear Regulatory Commission (NRC) is currently performing research on the development of probabilistic models for digital systems for inclusion in PRAs; however, no consensus methodology exists at this time. Westinghouse is currently updating the AP1000 plant PRA to support initial operation of plants currently under construction in the United States. The digital RPS is modeled using fault tree methodology similar to that used for analog based systems. This paper presents high level descriptions of a typical analog based RPS and of the AP1000 plant digital RPS. Application of current fault

  13. Estudo piloto dos efeitos da terapia hormonal sobre o tecido mamário normal de mulheres após a menopausa A pilot study of the effects of hormone therapy on normal breast tissue of postmenopausal women

    Directory of Open Access Journals (Sweden)

    Simone Elias

    2006-11-01

    Full Text Available OBJETIVOS: avaliou-se o tecido mamário de mulheres antes e depois de seis meses de terapia estroprogestativa combinada contínua (0,625 mg de estrogênios conjugados eqüinos associados a 2,5 mg de acetato de medroxiprogesterona. MÉTODOS: todas as pacientes foram avaliadas antes de se instituir o tratamento e consideradas aptas para este. Foram obtidos fragmentos de tecido mamário por meio de biópsia percutânea com agulha grossa (acoplada a um propulsor automático - "core-biópsia". O material foi fixado e os cortes corados por hematoxilina-eosina. Avaliou-se a densidade epitelial e o volume nuclear do epitélio mamário antes e após a terapia hormonal. Esses parâmetros morfométricos foram analisados graficamente com auxílio do programa Imagelab 2000 ®, após captura da imagem microscópica pelo sistema Vidcap 32. Esse programa permite que sejam selecionadas as áreas de interesse, possibilitando o cálculo de área, volume ou a relação da área ocupada entre diferentes estruturas. RESULTADOS: depois do uso da terapia, o volume nuclear nas mulheres em que o tratamento foi instituído em período mais tardio após a menopausa mostrou um aumento de cerca de 33% (de 103,6 para 138,1 µm³. A densidade epitelial não se modificou de forma significativa: o valor médio antes da terapia hormonal foi de 0,08 e após de 0,10. CONCLUSÕES: a terapia estroprogestativa combinada contínua empregada por seis meses induziu à alteração no volume nuclear das células epiteliais das mamas, sugerindo aumento de sua atividade metabólica. Provavelmente, esse evento precede outros que confirmariam o estímulo da proliferação celular por esses hormônios.PURPOSE: to analyze breast tissue of postmenopausal women before and after six months of continuous combined estrogen-progestin replacement therapy (0.625 mg conjugated equine estrogens associated with 2.5 mg medroxyprogesterone acetate. METHODS: all patients were evaluated before treatment and

  14. AP1000 shield building: a constructability challenge

    International Nuclear Information System (INIS)

    Di Giuseppe, Giovanni; Bonanno, Domenico

    2010-01-01

    The AP1000 Shield Building, an enhanced structure which surrounds the containment vessel, consists of standard Reinforced Concrete (RC) and composite Steel and Concrete (SC) construction. In the SC module the surface steel plates, (with attached shear studs and angles) filled with concrete, act as the steel reinforcement in concrete. This is a relatively new design technology that required the appropriate use of structural codes, supplemented with information from applicable tests on similar composite steel and concrete construction. Being a newer design concept, existing codes do not provide explicit guidance on SC construction so a review of literature and test data on composite structures similar to AP1000 shield building was done in order to confirm the technical basis for the design. The SC walls, air inlet structure and roof of the Shield Building will be constructed using modular construction practices and then transported to site and lifted into place. These modules, working also as permanent form-work, will be filled with high strength Self- Consolidating Concrete. (SCC) This paper provides a focused and integrated presentation of the enhanced shield building design methodology, testing, constructability and inspection. (authors)

  15. A study of atomic distribution in the intermetallic compound by AP-FIM

    International Nuclear Information System (INIS)

    Ren, D.G.

    1993-01-01

    This paper reports a study of the atomic distributions in the intermetallic compound by field ion microscope and atom probe (AP-FIM). The samples used in this work had nearly stoichiometry composition of Ni 3 Al with boron and without boron. The samples of TiAl also had nearly stoichiometry composition and adding Zr and Mn. The field ion image of Ni 3 Al without boron displays essentially the ordered f.c.c. crystal structure (Ll 2 ) with the center of (001) face. The field ion image of B-doped Ni 3 Al shows that the extent of ordering is reduced by addition of boron. The results of AP analysis show that the distribution of boron atom in Ni 3 Al is approximately homogeneous for the low boron contents. The atomic arrangements of Ni and Al in Ni 3 Al crystal lattice were changed by addition of boron. It is shown in the probability of consecutive evaporative sequence Al-Al and Ni-Ni is increased with B-doping. The field ion image of TiAl shows two regions with ordered f.c.t crystal structure (r-TiAl) and disordered. The distributions of Ti and Al atoms in the TiAl alloy show that the structure of a lamellar mixture were confirmed by AP profiles. The results of AP analysis show that distributions of Ti, Al, Mn and Zr in the alloy essentially is homogeneous. The results of AP analysis also exhibit that the interface of an oxide exists in the alloys. These interfaces of oxides consist of TiO and AlO in the TiAl, NiO in the Ni 3 Al. The broadness of the oxides interface were estimated about 8-10nm

  16. Origination, expansion, evolutionary trajectory, and expression bias of AP2/ERF superfamily in Brassica napus

    Directory of Open Access Journals (Sweden)

    Xiaoming Song

    2016-08-01

    Full Text Available The AP2/ERF superfamily, one of the most important transcription factor families, plays crucial roles in response to biotic and abiotic stresses. So far, a comprehensive evolutionary inference of its origination and expansion has not been available. Here, we identified 515 AP2/ERF genes in B. napus, a neo-tetraploid forming ~7500 years ago, and found that 82.14% of them were duplicated in the tetraploidization. A prominent subgenome bias was revealed in gene expression, tissue-specific, and gene conversion. Moreover, a large-scale analysis across plants and alga suggested that this superfamily could have been originated from AP2 family, expanding to form other families (ERF, and RAV. This process was accompanied by duplicating and/or alternative deleting AP2 domain, intragenic domain sequence conversion, and/or by acquiring other domains, resulting in copy number variations, alternatively contributing to functional innovation. We found that significant positive selection occurred at certain critical nodes during the evolution of land plants, possibly responding to changing environment. In conclusion, the present research revealed origination, functional innovation, and evolutionary trajectory of the AP2/ERF superfamily, contributing to understanding their roles in plant stress tolerance.

  17. The APS thin pulsed septum magnets

    International Nuclear Information System (INIS)

    Lopez, F.; Mills, F.; Milton, S.; Reeves, S.; Sheynin, S.; Thompson, K.; Turner, L.

    1994-01-01

    A thin (2-mm) eddy-current pulsed septum magnet was developed for use in the Advanced Photon Source (APS) machines. A number of different configurations of the magnet were assembled and tested in an effort to minimize the undesired leakage field in the stored-beam region. However, because of measured excessive leakage fields, an alternative direct-drive septum magnet was also constructed and tested. We present here the design specifications and acceptable performance criteria along with results of magnetic field measurements

  18. Correction magnet power supplies for APS machine

    International Nuclear Information System (INIS)

    Kang, Y.G.

    1991-01-01

    The Advanced Photon Source machine requires a number of correction magnets; five kinds for the storage ring, two for the injector synchrotron, and two for the positron accumulator ring. Three types of bipolar power supply will be used for all the correction magnets. This paper describes the design aspects and considerations for correction magnet power supplies for the APS machine. 3 refs., 3 figs., 1 tab

  19. NRC confirmatory safety system testing in support of AP600 design review

    International Nuclear Information System (INIS)

    Rhee, G.S.; Bessette, D.E.; Shotkin, L.M.

    1994-01-01

    Westinghouse Electric Corporation has submitted the Advanced Passive 600 MWe (AP600) nuclear power plant design to the NRC for design certification. The Office of Nuclear Regulatory Research is proceeding to conduct confirmatory testing to help the NRC staff evaluate the AP600 safety system design. For confirmatory testing, it was determined that the cost-effective route was to modify an existing full-height, full-pressure test facility rather than build a new one. Thus, all the existing integral effects test facilities, both in the US and abroad, were screened to select the best candidate. As a result, the ROSA-V (Rig of Safety Assessment-V) test facility located in the Japan Atomic Energy Research Institute (JAERI) was chosen. However, because of some differences in design between the existing ROSA-V facility and the AP600, the ROSA-V is being modified to conform to the AP600 safety system design. The modification work will be completed by the end of this year. A series of facility characterization tests will then be performed in January 1994 for the modified part of the facility before the main test series is initiated in February 1994. A total of 12 tests will be performed in 1994 under Phase I of this cooperative program with JAERI. Phase II testing is being considered to be conducted in 1995 mainly for beyond-design-basis accident evaluation

  20. Confirmatory analysis of the AP1000 passive residual heat removal heat exchanger with 3-D computational fluid dynamic analysis

    International Nuclear Information System (INIS)

    Schwall, James R.; Karim, Naeem U.; Thakkar, Jivan G.; Taylor, Creed; Schulz, Terry; Wright, Richard F.

    2006-01-01

    The AP1000 is an 1100 MWe advanced nuclear power plant that uses passive safety features to enhance plant safety and to provide significant and measurable improvements in plant simplification, reliability, investment protection and plant costs. The AP1000 received final design approval from the US-NRC in 2004. The AP1000 design is based on the AP600 design that received final design approval in 1999. Wherever possible, the AP1000 plant configuration and layout was kept the same as AP600 to take advantage of the maturity of the design and to minimize new design efforts. As a result, the two-loop configuration was maintained for AP1000, and the containment vessel diameter was kept the same. It was determined that this significant power up-rate was well within the capability of the passive safety features, and that the safety margins for AP1000 were greater than those of operating PWRs. A key feature of the passive core cooling system is the passive residual heat removal heat exchanger (PRHR HX) that provides decay heat removal for postulated LOCA and non-LOCA events. The PRHR HX is a C-tube heat exchanger located in the in-containment refueling water storage tank (IRWST) above the core promoting natural circulation heat removal between the reactor cooling system and the tank. Component testing was performed for the AP600 PRHR HX to determine the heat transfer characteristics and to develop correlations to be used for the AP1000 safety analysis codes. The data from these tests were confirmed by subsequent integral tests at three separate facilities including the ROSA facility in Japan. Owing to the importance of this component, an independent analysis has been performed using the ATHOS-based computational fluid dynamics computer code PRHRCFD. Two separate models of the PRHR HX and IRWST have been developed representing the ROSA test geometry and the AP1000 plant geometry. Confirmation of the ROSA test results were used to validate PRHRCFD, and the AP1000 plant model