WorldWideScience

Sample records for nonreinforced probe trials

  1. The Proportion of Fixed Interval Trials to Probe Trials Affects Acquisition of the Peak Procedure Fixed Interval Timing Task

    OpenAIRE

    2007-01-01

    A common procedure for studying the ability of animals to time is the peak procedure. With the peak procedure animals are first trained on a fixed interval schedule (i.e., 30 seconds). After the animals have been well trained on the fixed interval schedule, probe trials are introduced. On probe trials the stimulus is presented longer (i.e., 90 seconds) and the animal does not receive reinforcement for responding. When animals are first presented with probe trials responding remains flat follo...

  2. Teaching Children with Autism to Discriminate the Reinforced and Nonreinforced Responses of Others: Implications for Observational Learning

    Science.gov (United States)

    DeQuinzio, Jaime Ann; Taylor, Bridget A.

    2015-01-01

    We taught 4 participants with autism to discriminate between the reinforced and nonreinforced responses of an adult model and evaluated the effectiveness of this intervention using a multiple baseline design. During baseline, participants were simply exposed to adult models' correct and incorrect responses and the respective consequences of each.…

  3. A Probe Trial Procedure for the Study of Children's Discrimination Learning and Transfer

    Science.gov (United States)

    Cole, Michael

    1976-01-01

    A discrimination reversal problem was presented to 192 children varying in age from 3 to 5 years. At the end of both the initial learning and transfer trials, probe trials were introduced to ascertain the response rule describing children's choices. (Author/SB)

  4. Trial order and retention interval in human predictive judgment.

    Science.gov (United States)

    Stout, Steven C; Amundson, Jeffrey C; Miller, Ralph R

    2005-12-01

    The influences of order of trial type and retention interval on human predictive judgments were assessed for a cue that was reinforced on half of its training presentations. Subjects observed 10 cue-outcome presentations (i.e., reinforced trials) and 10 cue-alone presentations (i.e., nonreinforced trials) in one of three different orders: all nonreinforced trials followed by all reinforced trials(latent inhibition), reinforced and nonreinforced trials interspersed (partial reinforcement), or al lreinforced trials followed by all nonreinforced trials (extinction). Ratings were based mainly on the most recent event type (i.e., a recency effect) when the test occurred immediately after training but were based mainly on initial event types (i.e., a primacy effect) when the test occurred after a 48-h delay. The subjects tested both immediately and with a long retention interval did not exhibit this shift to primacy (i.e., the recency effect persisted). These results demonstrate noncatastrophic forgetting and the flexible use of trial order information in predictive judgments.

  5. Occasional Reinforced Trials during Extinction Can Slow the Rate of Rapid Reacquisition

    Science.gov (United States)

    Bouton, Mark E.; Woods, Amanda M.; Pineno, Oskar

    2004-01-01

    Two appetitive conditioning experiments with rats examined reacquisition after conditioned responding was eliminated by either extinction or by a partial reinforcement procedure in which reinforced trials were occasionally presented among many nonreinforced trials. In Experiment 1, reacquisition to a conditional stimulus (CS) that had been…

  6. Indomethacin Increases Neurogenesis across Age Groups and Improves Delayed Probe Trial Difference Scores in Middle-Aged Rats

    Directory of Open Access Journals (Sweden)

    James A. McGuiness

    2017-09-01

    Full Text Available We tested whether indomethacin or rosiglitazone treatment could rejuvenate spatial ability and hippocampal neurogenesis in aging rats. Young (4 mo; n = 30, middle-aged (12 mo; n = 31, and aged (18 mo; n = 31 male Fischer 344 rats were trained and then tested in a rapid acquisition water maze task and then fed vehicle (500 μl strawberry milk, indomethacin (2.0 mg/ml, or rosiglitazone (8.0 mg/ml twice daily for the remainder of the experiment. A week after drug treatment commenced, the rats were given 3 daily BrdU (50 mg/kg injections to test whether age-related declines in neurogenesis were reversed. One week after the final BrdU injection (~2.5 weeks after the 1st water maze session, the rats were trained to a find novel hidden water maze platform location, tested on 15 min and 24 h probe trials and then killed 24 h later. During the first water maze session, young rats outperformed aged rats but all rats learned information about the hidden platform location. Middle-aged and aged rats exhibited better memory probe trial performances than young rats in the 2nd water maze session and indomethacin improved memory probe trial performances on the 2nd vs. 1st water maze session in middle-aged rats. Middle-aged rats with more new neurons had fewer phagocytic microglia and exhibited better hidden platform training trial performances on the 2nd water maze session. Regardless of age, indomethacin increased new hippocampal neuron numbers and both rosiglitazone and indomethacin increased subependymal neuroblasts/neuron densities. Taken together, our results suggest the feasibility of studying the effects of longer-term immunomodulation on age-related declines in cognition and neurogenesis.

  7. A placebo-controlled trial to evaluate an anesthetic gel when probing in patients with advanced periodontitis.

    LENUS (Irish Health Repository)

    Winning, Lewis

    2012-12-01

    The baseline periodontal examination is reported to be a painful dental procedure, but currently there are limited practical techniques to reduce this pain. The objective of this study is to evaluate the efficacy of an intrapocket anesthetic gel in the reduction of pain on periodontal probing in a group of untreated patients with generalized chronic periodontitis (CP).

  8. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    2013-01-01

    Mobile probing is a method, developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time and space......). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings point...... to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face). The development...

  9. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    2012-01-01

    Mobile probing is a method, which has been developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time...... and space). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings...... point to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face...

  10. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    2012-01-01

    Mobile probing is a method, which has been developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time...... and space). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings...... point to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face...

  11. NRTI Sparing Therapy in Virologically Controlled HIV-1 Infected Subjects: Results of a Controlled, Randomized Trial (Probe).

    Science.gov (United States)

    Maggiolo, Franco; Di Filippo, Elisa; Valenti, Daniela; Ortega, Paula S; Callegaro, Annapaola

    2016-05-01

    Dual treatments could help clinicians to avoid drawbacks and toxicities due to the nucleosidic backbone, while maintaining the efficacy and convenience of robust combination antiretroviral therapy (cART). We explored the combination of rilpivirine plus boosted darunavir (DRV) as an option when switching from standard cART in patients who are virologically suppressed. In this randomized, open-label, proof-of-concept, noninferiority trial, we recruited patients aged 18 years or older with chronic HIV-1 infection and on a stable, effective (>6 months) protease inhibitor-based cART including a nucleosidic backbone. The primary endpoint was noninferiority of the virological response between treatment groups, according to FDA snapshot approach. Sixty patients were randomly allocated to dual treatment with rilpivirine plus boosted DRV or to continue their ongoing triple treatment. Noninferiority was shown at the prespecified level of -12% both at 24 and 48 weeks. At week 24, 100% of patients in the dual arm presented a blood HIV-RNA level therapy arm. At week 48, the CD838HLADR cell count was 3.4% (SD, 2.2) in the dual-therapy arm and 5.2% (SD, 3.1) in the triple arm (P = 0.018). None of the patients developed severe adverse events nor had to stop treatment because of adverse events or presented grade 3-4 laboratory abnormalities. A greater reduction of bone stiffness (-2.25; SD, 7.1) was observed in patients randomized to continue triple therapy compared with patients switched to dual therapy (-0.32; SD, 8.8). Finally, baseline HIV-DNA content directly correlated with pre-cART viral load of patients (P = 0.021), but not with time on cART or time with HIV-RNA below 50 copies per milliliter. Independently of the study arm, patients with a n HIV-RNA level constantly above 3 copies per milliliter or showing viral blips had baseline HIV-DNA levels significantly higher (64,656 copies per 10 cells; SD, 93057) compared with patients who constantly presented a HIV-RNA level below

  12. Trials

    Directory of Open Access Journals (Sweden)

    Michele Fornaro

    2010-01-01

    Full Text Available Mental Retardation (MR is a developmental disability characterized by impairments in adaptive daily life skills and difficulties in social and interpersonal functioning. Since multiple causes may contribute to MR, associated clinical pictures may vary accordingly. Nevertheless, when psychiatric disorders as Treatment Resistant Depression (TRD and/or alcohol abuse co-exist, their proper detection and management is often troublesome, essentially due to a limited vocabulary MR people could use to describe their symptoms, feelings and concerns, and the lack of reliable screening tools. Furthermore, MR people are among the most medicated subjects, with (over prescription of antidepressants and/or typical antipsychotics being the rule rather than exception. Thus, treatment resistance or even worsening of depression, constitute frequent occurrences. This report describes the case of a person with MR who failed to respond to repetitive trials of antidepressant monotherapies, finally recovering using aripiprazole to fluvoxamine augmentation upon consideration of a putative bipolar diathesis for “agitated” TRD. Although further controlled investigations are needed to assess a putative bipolar diathesis in some cases of MR associated to TRD, prudence is advised in the long-term prescription of antidepressant monotherapies in such conditions.

  13. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    2013-01-01

    to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face). The development...

  14. Probe Storage

    NARCIS (Netherlands)

    Gemelli, Marcellino; Abelmann, Leon; Engelen, Johan B.C.; Khatib, Mohammed G.; Koelmans, Wabe W.; Zaboronski, Olog; Campardo, Giovanni; Tiziani, Federico; Laculo, Massimo

    2011-01-01

    This chapter gives an overview of probe-based data storage research over the last three decades, encompassing all aspects of a probe recording system. Following the division found in all mechanically addressed storage systems, the different subsystems (media, read/write heads, positioning, data chan

  15. Cultural probes

    DEFF Research Database (Denmark)

    Madsen, Jacob Østergaard

    2016-01-01

    The aim of this study was thus to explore cultural probes (Gaver, Boucher et al. 2004), as a possible methodical approach, supporting knowledge production on situated and contextual aspects of occupation.......The aim of this study was thus to explore cultural probes (Gaver, Boucher et al. 2004), as a possible methodical approach, supporting knowledge production on situated and contextual aspects of occupation....

  16. The CYTONOX trial

    DEFF Research Database (Denmark)

    Gade, Christina; Mikus, Gerd; Christensen, Hanne Rolighed

    2016-01-01

    will be defined by using well-tested probes; midazolam, chlorzoxazone and caffeine. Each of the probes will be administered as a single dose. Subsequently, blood and urine samples will be collected at pre-specified times. CONCLUSION: The aim of the CYTONOX trial is to investigate the in vivo activity of CYP3A4...

  17. Mobile probes

    DEFF Research Database (Denmark)

    2016-01-01

    A project investigating the effectiveness of a collection of online resources for teachers' professional development used mobile probes as a data collection method. Teachers received questions and tasks on their mobile in a dialogic manner while in their everyday context as opposed to in an inter......A project investigating the effectiveness of a collection of online resources for teachers' professional development used mobile probes as a data collection method. Teachers received questions and tasks on their mobile in a dialogic manner while in their everyday context as opposed...... to in an interview. This method provided valuable insight into the contextual use, i.e. how did the online resource transfer to the work practice. However, the research team also found that mobile probes may provide the scaffolding necessary for individual and peer learning at a very local (intra-school) community...... level. This paper is an initial investigation of how the mobile probes process proved to engage teachers in their efforts to improve teaching. It also highlights some of the barriers emerging when applying mobile probes as a scaffold for learning....

  18. Endocavity Ultrasound Probe Manipulators.

    Science.gov (United States)

    Stoianovici, Dan; Kim, Chunwoo; Schäfer, Felix; Huang, Chien-Ming; Zuo, Yihe; Petrisor, Doru; Han, Misop

    2013-06-01

    We developed two similar structure manipulators for medical endocavity ultrasound probes with 3 and 4 degrees of freedom (DoF). These robots allow scanning with ultrasound for 3-D imaging and enable robot-assisted image-guided procedures. Both robots use remote center of motion kinematics, characteristic of medical robots. The 4-DoF robot provides unrestricted manipulation of the endocavity probe. With the 3-DoF robot the insertion motion of the probe must be adjusted manually, but the device is simpler and may also be used to manipulate external-body probes. The robots enabled a novel surgical approach of using intraoperative image-based navigation during robot-assisted laparoscopic prostatectomy (RALP), performed with concurrent use of two robotic systems (Tandem, T-RALP). Thus far, a clinical trial for evaluation of safety and feasibility has been performed successfully on 46 patients. This paper describes the architecture and design of the robots, the two prototypes, control features related to safety, preclinical experiments, and the T-RALP procedure.

  19. Conductivity Probe

    Science.gov (United States)

    2008-01-01

    The Thermal and Electrical Conductivity Probe (TECP) for NASA's Phoenix Mars Lander took measurements in Martian soil and in the air. The needles on the end of the instrument were inserted into the Martian soil, allowing TECP to measure the propagation of both thermal and electrical energy. TECP also measured the humidity in the surrounding air. The needles on the probe are 15 millimeters (0.6 inch) long. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  20. Pollution Probe.

    Science.gov (United States)

    Chant, Donald A.

    This book is written as a statement of concern about pollution by members of Pollution Probe, a citizens' anti-pollution group in Canada. Its purpose is to create public awareness and pressure for the eventual solution to pollution problems. The need for effective government policies to control the population explosion, conserve natural resources,…

  1. Incidences of vaccine-preventable Haemophilus influenzae type b pneumonia and meningitis in Indonesian children: hamlet-randomised vaccine-probe trial.

    Science.gov (United States)

    Gessner, Bradford D; Sutanto, Agustinus; Linehan, Mary; Djelantik, I Gusti Gede; Fletcher, Tracy; Gerudug, I Komang; Ingerani; Mercer, David; Moniaga, Vanda; Moulton, Lawrence H; Moulton, Lawrence H; Mulholland, Kim; Nelson, Carib; Soemohardjo, Soewignjo; Steinhoff, Mark; Widjaya, Anton; Stoeckel, Philippe; Maynard, James; Arjoso, Soemarjati

    Most studies of Haemophilus influenzae type b (Hib) disease in Asia have found low rates, and few Asian countries use Hib vaccine in routine immunisation programmes. Whether Hib disease truly is rare or whether many cases remain undetected is unclear. To estimate incidences of vaccine-preventable Hib pneumonia and meningitis among children younger than 2 years in Lombok, Indonesia, during 1998-2002, we undertook a hamlet-randomised, controlled, double-blind vaccine-probe study (818 hamlets). Children were immunised (WHO schedule) with diphtheria, tetanus, pertussis (DTP) or DTP-PRP-T (Hib conjugate) vaccine. Vaccine-preventable disease incidences were calculated as the difference in rates of clinical outcomes between DTP and DTP-PRP-T groups. Analyses included all children who received at least one vaccine dose. We enrolled 55073 children: 28147 were assigned DTP-PRP-T and 26926 DTP. The proportion of pneumonia outcomes prevented by vaccine ranged from less than 0 to 4.8%. Calculated incidences of vaccine-preventable Hib disease (per 10(5) child-years of observation) for outcome categories were: substantial alveolar consolidation or effusion, less than zero (-43 [95% CI -185 to 98]); all severe pneumonia, 264 (95% CI less than zero to 629); all clinical pneumonia, 1561 (270 to 2853); confirmed Hib meningitis, 16 (1.4 to 31); meningitis with cerebrospinal-fluid findings consistent with a bacterial aetiology, 67 (22 to 112); and admission for suspected meningitis or presenting to a clinic with convulsions, 158 (42 to 273). Hib vaccine did not prevent the great majority of pneumonia cases, including those with alveolar consolidation. These results do not support a major role for Hib vaccine in overall pneumonia-prevention programmes. Nevertheless, the study identified high incidences of Hib meningitis and pneumonia; inclusion of Hib vaccine in routine infant immunisation programmes in Asia deserves consideration.

  2. The Effectiveness of Specific Exercise Approach or Modifiable Heel Lift in the Treatment of Functional Leg Length Discrepancy in Early Post-surgery Inpatients after Total Hip Arthroplasty: A Randomized Controlled Trial with a PROBE design

    Science.gov (United States)

    NAKANOWATARI, Tatsuya; SUZUKAMO, Yoshimi; IZUMI, Shin-Ichi

    2016-01-01

    Objective: This study investigated the effectiveness of a specific exercise approach (SEA) or modifiable heel lift (MHL) to improve functional leg length discrepancy (LLD) after total hip arthroplasty (THA). Methods: The study was a randomized controlled trial with a PROBE (prospective, randomized, open, blinded-endpoint) design trial. Patients (n=33) with both functional and perceived LLDs, 1 week after THA, were randomized to the SEA, MHL, or control groups. Patients in the SEA group performed 2 weeks of exercises to improve hip contracture and lumbar scoliosis. Patients in the MHL group used an insole-type heel lift to correct functional LLD. The control group received normal postoperative care, comprising standard rehabilitation after THA. The primary outcomes were functional LLD, measured by a block test, and patient-perceived LLD at 3 weeks after the surgery. Secondary outcomes included the visual analog scale (VAS) for pain, the Timed Up and Go (TUG) test, and the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC) at 3 weeks after the surgery. Results: The functional LLDs (mean ± SD) for the SEA (3.3 ± 3.1 mm) and MHL (2.2 ± 2.1 mm) groups were significantly smaller than for the control group (6.4 ± 4.0 mm). The degree of patient-perceived LLD differed significantly between the SEA and the control groups (p=.005). Conclusions: SEA and MHL use, during early post-operative recovery, can produce relevant changes in functional LLD after THA. PMID:28289580

  3. Proximal Probes Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Proximal Probes Facility consists of laboratories for microscopy, spectroscopy, and probing of nanostructured materials and their functional properties. At the...

  4. Probe tip heating assembly

    Science.gov (United States)

    Schmitz, Roger William; Oh, Yunje

    2016-10-25

    A heating assembly configured for use in mechanical testing at a scale of microns or less. The heating assembly includes a probe tip assembly configured for coupling with a transducer of the mechanical testing system. The probe tip assembly includes a probe tip heater system having a heating element, a probe tip coupled with the probe tip heater system, and a heater socket assembly. The heater socket assembly, in one example, includes a yoke and a heater interface that form a socket within the heater socket assembly. The probe tip heater system, coupled with the probe tip, is slidably received and clamped within the socket.

  5. Mobile Game Probes

    DEFF Research Database (Denmark)

    Borup Lynggaard, Aviaja

    2006-01-01

    This paper will examine how probes can be useful for game designers in the preliminary phases of a design process. The work is based upon a case study concerning pervasive mobile phone games where Mobile Game Probes have emerged from the project. The new probes are aimed towards a specific target...... group and the goal is to specify the probes so they will cover the most relevant areas for our project. The Mobile Game Probes generated many interesting results and new issues occurred, since the probes came to be dynamic and favorable for the process in new ways....

  6. Properties of Ultrasound Probes

    OpenAIRE

    Rusina, M.

    2015-01-01

    This work deals with the measurement properties of ultrasound probes. Ultrasound probes and their parameters significantly affect the quality of the final image. In this work there are described the possibility of measuring the spatial resolution, sensitivity of the probe and measuring the length of the dead zone. Ultrasound phantom ATS Multi Purpose Phantom Type 539 was used for measurements.

  7. Atom probe crystallography

    National Research Council Canada - National Science Library

    Gault, Baptiste; Moody, Michael P; Cairney, Julie M; Ringer, Simon P

    2012-01-01

    This review addresses new developments in the emerging area of "atom probe crystallography", a materials characterization tool with the unique capacity to reveal both composition and crystallographic...

  8. Pioneer Jupiter orbiter probe mission 1980, probe description

    Science.gov (United States)

    Defrees, R. E.

    1974-01-01

    The adaptation of the Saturn-Uranus Atmospheric Entry Probe (SUAEP) to a Jupiter entry probe is summarized. This report is extracted from a comprehensive study of Jovian missions, atmospheric model definitions and probe subsystem alternatives.

  9. Effects of Error Correction during Assessment Probes on the Acquisition of Sight Words for Students with Moderate Intellectual Disabilities

    Science.gov (United States)

    Waugh, Rebecca E.; Alberto, Paul A.; Fredrick, Laura D.

    2011-01-01

    Simultaneous prompting is an errorless learning strategy designed to reduce the number of errors students make; however, research has shown a disparity in the number of errors students make during instructional versus probe trials. This study directly examined the effects of error correction versus no error correction during probe trials on the…

  10. An Ultrasonographic Periodontal Probe

    Science.gov (United States)

    Bertoncini, C. A.; Hinders, M. K.

    2010-02-01

    Periodontal disease, commonly known as gum disease, affects millions of people. The current method of detecting periodontal pocket depth is painful, invasive, and inaccurate. As an alternative to manual probing, an ultrasonographic periodontal probe is being developed to use ultrasound echo waveforms to measure periodontal pocket depth, which is the main measure of periodontal disease. Wavelet transforms and pattern classification techniques are implemented in artificial intelligence routines that can automatically detect pocket depth. The main pattern classification technique used here, called a binary classification algorithm, compares test objects with only two possible pocket depth measurements at a time and relies on dimensionality reduction for the final determination. This method correctly identifies up to 90% of the ultrasonographic probe measurements within the manual probe's tolerance.

  11. Hard probes 2006 Asilomar

    CERN Multimedia

    2006-01-01

    "The second international conference on hard and electromagnetic probes of high-energy nuclear collisions was held June 9 to 16, 2006 at the Asilomar Conference grounds in Pacific Grove, California" (photo and 1/2 page)

  12. Clinical Trials

    Science.gov (United States)

    Clinical trials are research studies that test how well new medical approaches work in people. Each study answers ... prevent, screen for, diagnose, or treat a disease. Clinical trials may also compare a new treatment to a ...

  13. Humble Probe into the Principles of Court Trial of Not-Guilty-Pleading Cases%辩称无罪案之庭审质证原则初探

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    With the innocent presupposition principle, the Procedure Law amended in 2012 makes it clearer that it is the public prosecution agencies that should take the responsibility of giving evidences in public prosecution cases and emphasizes that anyone should not be compelled to make self-crimination, and stipulates that while conducting interrogation, criminal investigators should tell criminal suspects only when they confess offences truthfully can they be punished leniently. To some extent, there exists the right to keep silent in our legislation. Accordingly, it is necessary to analyze the characteristics and consequences of statements of the accused, to have the notion that evidences are highly important and to grasp the principles concerned in court trial.%  2012年刑事诉讼法修正时,在原有无罪推定原则前提下,进一步明确了公诉案件中被告人有罪的举证责任由公诉机关承担,同时强调不得强迫任何人证实自己有罪,并规定侦查人员在讯问的时候,应当告知犯罪嫌疑人如实供述自己罪行可以从宽处理的法律规定。从某种意义上说,我国立法实际已确立“沉默权”内容。因此,需要分析被告人“口供”的特点及后果,树立刑事诉讼“证据为王”的观念,在法庭审理中特别要把握若干质证规则。

  14. Multi-element eddy current probe. For inspecting steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Savin, E.; Sartre, B. [FRAMATOME, 92 - Paris-La-Defense (France); Placko, D.; Premel, D. [Ecole Nationale Superieure de Cachan, 94 (France)

    2000-10-01

    Framatome and the Ecole Normale Superieure de Cachan are developing a multi-element eddy current probe for inspecting steam generator tubes of 900 MWe PWR reactors. The device is intended to replace much slower rotating probes. Using its measurements, the conductivity image of any point in the tube can be reconstructed, thanks to a numerical, thanks to a numerical model, thus allowing diagnosis. The first trial results on mockups seem already competitive with those obtained using a rotary probe. (authors)

  15. Assessment of the Effect of Intestinal Permeability Probes (Lactulose And Mannitol and Other Liquids on Digesta Residence Times in Various Segments of the Gut Determined by Wireless Motility Capsule: A Randomised Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Ivana R Sequeira

    precluded the identification of all but gross variation between treatments. The lack of any differences between treatments in either total small or large intestinal transit times indicates that the solutions administered in the lactulose mannitol test of permeability had no consistent influence on the temporal pattern of absorption. The negatively exponential profile and lack of any peaks in the frequency spectra of cyclic variation in gastric intraluminal pressure that were consistent with reported physiological frequencies of contractile activity profile suggests that the principal source of this variation is stochastic likely resulting from the effects of external events occasioned by normal daily activities on intra-abdominal pressure.Australian New Zealand Clinical Trials Registry ACTRN12615000596505.

  16. Hard Probes at ATLAS

    CERN Document Server

    Citron, Z; The ATLAS collaboration

    2014-01-01

    The ATLAS collaboration has measured several hard probe observables in Pb+Pb and p+Pb collisions at the LHC. These measurements include jets which show modification in the hot dense medium of heavy ion collisions as well as color neutral electro-weak bosons. Together, they elucidate the nature of heavy ion collisions.

  17. One-Probe Search

    DEFF Research Database (Denmark)

    Östlin, Anna; Pagh, Rasmus

    2002-01-01

    We consider dictionaries that perform lookups by probing a single word of memory, knowing only the size of the data structure. We describe a randomized dictionary where a lookup returns the correct answer with probability 1 - e, and otherwise returns don't know. The lookup procedure uses an expan...

  18. Probing the Solar System

    Science.gov (United States)

    Wilkinson, John

    2013-01-01

    Humans have always had the vision to one day live on other planets. This vision existed even before the first person was put into orbit. Since the early space missions of putting humans into orbit around Earth, many advances have been made in space technology. We have now sent many space probes deep into the Solar system to explore the planets and…

  19. One-Probe Search

    DEFF Research Database (Denmark)

    Östlin, Anna; Pagh, Rasmus

    2002-01-01

    We consider dictionaries that perform lookups by probing a single word of memory, knowing only the size of the data structure. We describe a randomized dictionary where a lookup returns the correct answer with probability 1 - e, and otherwise returns don't know. The lookup procedure uses an expan...

  20. Probing the Solar System

    Science.gov (United States)

    Wilkinson, John

    2013-01-01

    Humans have always had the vision to one day live on other planets. This vision existed even before the first person was put into orbit. Since the early space missions of putting humans into orbit around Earth, many advances have been made in space technology. We have now sent many space probes deep into the Solar system to explore the planets and…

  1. EDITORIAL: Probing the nanoworld Probing the nanoworld

    Science.gov (United States)

    Miles, Mervyn

    2009-10-01

    In nanotechnology, it is the unique properties arising from nanometre-scale structures that lead not only to their technological importance but also to a better understanding of the underlying science. Over the last twenty years, material properties at the nanoscale have been dominated by the properties of carbon in the form of the C60 molecule, single- and multi-wall carbon nanotubes, nanodiamonds, and recently graphene. During this period, research published in the journal Nanotechnology has revealed the amazing mechanical properties of such materials as well as their remarkable electronic properties with the promise of new devices. Furthermore, nanoparticles, nanotubes, nanorods, and nanowires from metals and dielectrics have been characterized for their electronic, mechanical, optical, chemical and catalytic properties. Scanning probe microscopy (SPM) has become the main characterization technique and atomic force microscopy (AFM) the most frequently used SPM. Over the past twenty years, SPM techniques that were previously experimental in nature have become routine. At the same time, investigations using AFM continue to yield impressive results that demonstrate the great potential of this powerful imaging tool, particularly in close to physiological conditions. In this special issue a collaboration of researchers in Europe report the use of AFM to provide high-resolution topographical images of individual carbon nanotubes immobilized on various biological membranes, including a nuclear membrane for the first time (Lamprecht C et al 2009 Nanotechnology 20 434001). Other SPM developments such as high-speed AFM appear to be making a transition from specialist laboratories to the mainstream, and perhaps the same may be said for non-contact AFM. Looking to the future, characterisation techniques involving SPM and spectroscopy, such as tip-enhanced Raman spectroscopy, could emerge as everyday methods. In all these advanced techniques, routinely available probes will

  2. Calibration Fixture For Anemometer Probes

    Science.gov (United States)

    Lewis, Charles R.; Nagel, Robert T.

    1993-01-01

    Fixture facilitates calibration of three-dimensional sideflow thermal anemometer probes. With fixture, probe oriented at number of angles throughout its design range. Readings calibrated as function of orientation in airflow. Calibration repeatable and verifiable.

  3. Probing properties of cold radiofrequency plasma with polymer probe

    Science.gov (United States)

    Bormashenko, E.; Chaniel, G.; Multanen, V.

    2015-01-01

    The probe intended for the characterization of cold plasma is introduced. The probe allows the estimation of Debye length of cold plasma. The probe is based on the pronounced modification of surface properties (wettability) of polymer films by cold plasmas. The probe was tested with the cold radiofrequency inductive air plasma discharge. The Debye length and the concentration of charge carriers were estimated for various gas pressures. The reported results coincide reasonably with the corresponding values established by other methods. The probe makes possible measurement of characteristics of cold plasmas in closed chambers.

  4. Probing Properties of Cold Radiofrequency Plasma with Polymer Probe

    CERN Document Server

    Bormashenko, Edward; Multanen, Victor

    2014-01-01

    The probe intended for the characterization of cold plasma is introduced. The probe allows estimation of the Debye length of the cold plasma. The probe is based on the pronounced modification of surface properties (wettability) of polymer films by cold plasmas. The probe was tested with the cold radiofrequency inductive air plasma discharge. The Debye length and the concentration of charge carriers were estimated for various gas pressures. The reported results coincide reasonably with the corresponding values established by other methods. The probe makes possible measurement of characteristics of cold plasmas in closed chambers.

  5. Phoenix Conductivity Probe

    Science.gov (United States)

    2008-01-01

    This image taken by the Surface Stereo Imager on Sol 49, or the 49th Martian day of the mission (July 14, 2008), shows thermal and electrical conductivity probe on NASA's Phoenix Mars Lander's Robotic Arm. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is led by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  6. Atom probe tomography today

    OpenAIRE

    Alfred Cerezo; Peter H. Clifton; Mark J. Galtrey; Humphreys, Colin J.; Kelly, Thomas. F.; David J. Larson; Sergio Lozano-Perez; Marquis, Emmanuelle A.; Oliver, Rachel A.; Gang Sha; Keith Thompson; Mathijs Zandbergen; Roger L. Alvis

    2007-01-01

    This review aims to describe and illustrate the advances in the application of atom probe tomography that have been made possible by recent developments, particularly in specimen preparation techniques (using dual-beam focused-ion beam instruments) but also of the more routine use of laser pulsing. The combination of these two developments now permits atomic-scale investigation of site-specific regions within engineering alloys (e.g. at grain boundaries and in the vicinity of cracks) and also...

  7. Einstein Inflationary Probe (EIP)

    Science.gov (United States)

    Hinshaw, Gary

    2004-01-01

    I will discuss plans to develop a concept for the Einstein Inflation Probe: a mission to detect gravity waves from inflation via the unique signature they impart to the cosmic microwave background (CMB) polarization. A sensitive CMB polarization satellite may be the only way to probe physics at the grand-unified theory (GUT) scale, exceeding by 12 orders of magnitude the energies studied at the Large Hadron Collider. A detection of gravity waves would represent a remarkable confirmation of the inflationary paradigm and set the energy scale at which inflation occurred when the universe was a fraction of a second old. Even a strong upper limit to the gravity wave amplitude would be significant, ruling out many common models of inflation, and pointing to inflation occurring at much lower energy, if at all. Measuring gravity waves via the CMB polarization will be challenging. We will undertake a comprehensive study to identify the critical scientific requirements for the mission and their derived instrumental performance requirements. At the core of the study will be an assessment of what is scientifically and experimentally optimal within the scope and purpose of the Einstein Inflation Probe.

  8. Nanoscale thermal probing

    Directory of Open Access Journals (Sweden)

    Yanan Yue

    2012-03-01

    Full Text Available Nanoscale novel devices have raised the demand for nanoscale thermal characterization that is critical for evaluating the device performance and durability. Achieving nanoscale spatial resolution and high accuracy in temperature measurement is very challenging due to the limitation of measurement pathways. In this review, we discuss four methodologies currently developed in nanoscale surface imaging and temperature measurement. To overcome the restriction of the conventional methods, the scanning thermal microscopy technique is widely used. From the perspective of measuring target, the optical feature size method can be applied by using either Raman or fluorescence thermometry. The near-field optical method that measures nanoscale temperature by focusing the optical field to a nano-sized region provides a non-contact and non-destructive way for nanoscale thermal probing. Although the resistance thermometry based on nano-sized thermal sensors is possible for nanoscale thermal probing, significant effort is still needed to reduce the size of the current sensors by using advanced fabrication techniques. At the same time, the development of nanoscale imaging techniques, such as fluorescence imaging, provides a great potential solution to resolve the nanoscale thermal probing problem.

  9. Nine New Fluorescent Probes

    Science.gov (United States)

    Lin, Tsung-I.; Jovanovic, Misa V.; Dowben, Robert M.

    1989-06-01

    Absorption and fluorescence spectroscopic studies are reported here for nine new fluorescent probes recently synthesized in our laboratories: four pyrene derivatives with substituents of (i) 1,3-diacetoxy-6,8-dichlorosulfonyl, (ii) 1,3-dihydroxy-6,8-disodiumsulfonate, (iii) 1,3-disodiumsulfonate, and (iv) l-ethoxy-3,6,8-trisodiumsulfonate groups, and five [7-julolidino] coumarin derivatives with substituents of (v) 3-carboxylate-4-methyl, (vi) 3- methylcarboxylate, (vii) 3-acetate-4-methyl, (viii) 3-propionate-4-methyl, and (ix) 3-sulfonate-4-methyl groups. Pyrene compounds i and ii and coumarin compounds v and vi exhibit interesting absorbance and fluorescence properties: their absorption maxima are red shifted compared to the parent compound to the blue-green region, and the band width broadens considerably. All four blue-absorbing dyes fluoresce intensely in the green region, and the two pyrene compounds emit at such long wavelengths without formation of excimers. The fluorescence properties of these compounds are quite environment-sensitive: considerable spectral shifts and fluorescence intensity changes have been observed in the pH range from 3 to 10 and in a wide variety of polar and hydrophobic solvents with vastly different dielectric constants. The high extinction and fluorescence quantum yield of these probes make them ideal fluorescent labeling reagents for proteins, antibodies, nucleic acids, and cellular organelles. The pH and hydrophobicity-dependent fluorescence changes can be utilized as optical pH and/or hydrophobicity indicators for mapping environmental difference in various cellular components in a single cell. Since all nine probes absorb in the UV, but emit at different wavelengths in the visible, these two groups of compounds offer an advantage of utilizing a single monochromatic light source (e.g., a nitrogen laser) to achieve multi-wavelength detection for flow cytometry application. As a first step to explore potential application in

  10. Development of Mackintosh Probe Extractor

    Science.gov (United States)

    Rahman, Noor Khazanah A.; Kaamin, Masiri; Suwandi, Amir Khan; Sahat, Suhaila; Jahaya Kesot, Mohd

    2016-11-01

    Dynamic probing is a continuous soil investigation technique, which is one of the simplest soil penetration test. It basically consist of repeatedly driving a metal tipped probe into the ground using a drop weight of fixed mass and travel. Testing was carried out continuously from ground level to the final penetration depth. Once the soil investigation work done, it is difficult to pull out the probe rod from the ground, due to strong soil structure grip against probe cone and prevent the probe rod out from the ground. Thus, in this case, a tool named Extracting Probe was created to assist in the process of retracting the probe rod from the ground. In addition, Extracting Probe also can reduce the time to extract the probe rod from the ground compare with the conventional method. At the same time, it also can reduce manpower cost because only one worker involve to handle this tool compare with conventional method used two or more workers. From experiment that have been done we found that the time difference between conventional tools and extracting probe is significant, average time difference is 155 minutes. In addition the extracting probe can reduce manpower usage, and also labour cost for operating the tool. With all these advantages makes this tool has the potential to be marketed.

  11. Probe-based data storage

    CERN Document Server

    Koelmans, Wabe W; Abelmann, L

    2015-01-01

    Probe-based data storage attracted many researchers from academia and industry, resulting in unprecendeted high data-density demonstrations. This topical review gives a comprehensive overview of the main contributions that led to the major accomplishments in probe-based data storage. The most investigated technologies are reviewed: topographic, phase-change, magnetic, ferroelectric and atomic and molecular storage. Also, the positioning of probes and recording media, the cantilever arrays and parallel readout of the arrays of cantilevers are discussed. This overview serves two purposes. First, it provides an overview for new researchers entering the field of probe storage, as probe storage seems to be the only way to achieve data storage at atomic densities. Secondly, there is an enormous wealth of invaluable findings that can also be applied to many other fields of nanoscale research such as probe-based nanolithography, 3D nanopatterning, solid-state memory technologies and ultrafast probe microscopy.

  12. PROcess Based Diagnostics PROBE

    Science.gov (United States)

    Clune, T.; Schmidt, G.; Kuo, K.; Bauer, M.; Oloso, H.

    2013-01-01

    Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

  13. Atom probe tomography today

    Directory of Open Access Journals (Sweden)

    Alfred Cerezo

    2007-12-01

    Full Text Available This review aims to describe and illustrate the advances in the application of atom probe tomography that have been made possible by recent developments, particularly in specimen preparation techniques (using dual-beam focused-ion beam instruments but also of the more routine use of laser pulsing. The combination of these two developments now permits atomic-scale investigation of site-specific regions within engineering alloys (e.g. at grain boundaries and in the vicinity of cracks and also the atomic-level characterization of interfaces in multilayers, oxide films, and semiconductor materials and devices.

  14. Experimental probes of axions

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Aaron S.; /Fermilab

    2009-10-01

    Experimental searches for axions or axion-like particles rely on semiclassical phenomena resulting from the postulated coupling of the axion to two photons. Sensitive probes of the extremely small coupling constant can be made by exploiting familiar, coherent electromagnetic laboratory techniques, including resonant enhancement of transitions using microwave and optical cavities, Bragg scattering, and coherent photon-axion oscillations. The axion beam may either be astrophysical in origin as in the case of dark matter axion searches and solar axion searches, or created in the laboratory from laser interactions with magnetic fields. This note is meant to be a sampling of recent experimental results.

  15. Atom Probe Tomography 2012

    Science.gov (United States)

    Kelly, Thomas F.; Larson, David J.

    2012-08-01

    In the world of tomographic imaging, atom probe tomography (APT) occupies the high-spatial-resolution end of the spectrum. It is highly complementary to electron tomography and is applicable to a wide range of materials. The current state of APT is reviewed. Emphasis is placed on applications and data analysis as they apply to many fields of research and development including metals, semiconductors, ceramics, and organic materials. We also provide a brief review of the history and the instrumentation associated with APT and an assessment of the existing challenges in the field.

  16. Mobile Probing Kit

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Sørensen, Lene Tolstrup; Sørensen, J.K.

    2007-01-01

    characterized as being highly nomadic and thus potential users of mobile and ubiquitous technologies. The methodology has been applied in the 1ST MAGNET Beyond project in order to obtain user needs and requirements in the process of developing pilot services. We report on the initial findings from applying......Mobile Probing Kit is a low tech and low cost methodology for obtaining inspiration and insights into user needs, requirements and ideas in the early phases of a system's development process. The methodology is developed to identify user needs, requirements and ideas among knowledge workers...

  17. Stroke Trials Registry

    Science.gov (United States)

    ... News About Neurology Image Library Search The Internet Stroke Center Trials Registry Clinical Trials Interventions Conditions Sponsors ... a clinical trial near you Welcome to the Stroke Trials Registry Our registry of clinical trials in ...

  18. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... Z > Participating in Clinical Trials: About Clinical Trials In This Topic About Clinical Trials Risks and Benefits ... of this page please turn Javascript on. Participating in Clinical Trials About Clinical Trials A Research Study ...

  19. The Antartic Ice Borehole Probe

    Science.gov (United States)

    Behar, A.; Carsey, F.; Lane, A.; Engelhardt, H.

    2000-01-01

    The Antartic Ice Borehole Probe mission is a glaciological investigation, scheduled for November 2000-2001, that will place a probe in a hot-water drilled hole in the West Antartic ice sheet. The objectives of the probe are to observe ice-bed interactions with a downward looking camera, and ice inclusions and structure, including hypothesized ice accretion, with a side-looking camera.

  20. Micro scanning probes

    CERN Document Server

    Niblock, T

    2001-01-01

    This thesis covers the design methodology, theory, modelling, fabrication and evaluation of a Micro-Scanning-Probe. The device is a thermally actuated bimorph quadrapod fabricated using Micro Electro Mechanical Systems technology. A quadrapod is a structure with four arms, in this case a planar structure with the four arms forming a cross which is dry etched out of a silicon diaphragm. Each arm has a layer of aluminium deposited on it forming a bimorph. Through heating each arm actuation is achieved in the plane of the quadrapod and the direction normal to it. Fabrication of the device has required the development of bulk micromachining techniques to handle post CMOS fabricated wafers and the patterning of thickly sputtered aluminium in bulk micro machined cavities. CMOS fabrication techniques were used to incorporate diodes onto the quadrapod arms for temperature measurement of the arms. Fine tungsten and silicon tips have also been fabricated to allow tunnelling between the tip and the platform at the centr...

  1. Cosmological Probes for Supersymmetry

    Directory of Open Access Journals (Sweden)

    Maxim Khlopov

    2015-05-01

    Full Text Available The multi-parameter character of supersymmetric dark-matter models implies the combination of their experimental studies with astrophysical and cosmological probes. The physics of the early Universe provides nontrivial effects of non-equilibrium particles and primordial cosmological structures. Primordial black holes (PBHs are a profound signature of such structures that may arise as a cosmological consequence of supersymmetric (SUSY models. SUSY-based mechanisms of baryosynthesis can lead to the possibility of antimatter domains in a baryon asymmetric Universe. In the context of cosmoparticle physics, which studies the fundamental relationship of the micro- and macro-worlds, the development of SUSY illustrates the main principles of this approach, as the physical basis of the modern cosmology provides cross-disciplinary tests in physical and astronomical studies.

  2. Cosmological Probes for Supersymmetry

    CERN Document Server

    Khlopov, Maxim

    2015-01-01

    The multi-parameter character of supersymmetric dark-matter models implies the combination of their experimental studies with astrophysical and cosmological probes. The physics of the early Universe provides nontrivial effects of non-equilibrium particles and primordial cosmological structures. Primordial black holes (PBHs) are a profound signature of such structures that may arise as a cosmological consequence of supersymmetric (SUSY) models. SUSY-based mechanisms of baryosynthesis can lead to the possibility of antimatter domains in a baryon asymmetric Universe. In the context of cosmoparticle physics, which studies the fundamental relationship of the micro- and macro-worlds, the development of SUSY illustrates the main principles of this approach, as the physical basis of the modern cosmology provides cross-disciplinary tests in physical and astronomical studies.

  3. Spontaneous Symmetry Probing

    CERN Document Server

    Nicolis, Alberto

    2011-01-01

    For relativistic quantum field theories, we consider Lorentz breaking, spatially homogeneous field configurations or states that evolve in time along a symmetry direction. We dub this situation "spontaneous symmetry probing" (SSP). We mainly focus on internal symmetries, i.e. on symmetries that commute with the Poincare group. We prove that the fluctuations around SSP states have a Lagrangian that is explicitly time independent, and we provide the field space parameterization that makes this manifest. We show that there is always a gapless Goldstone excitation that perturbs the system in the direction of motion in field space. Perhaps more interestingly, we show that if such a direction is part of a non-Abelian group of symmetries, the Goldstone bosons associated with spontaneously broken generators that do not commute with the SSP one acquire a gap, proportional to the SSP state's "speed". We outline possible applications of this formalism to inflationary cosmology.

  4. New probe of naturalness.

    Science.gov (United States)

    Craig, Nathaniel; Englert, Christoph; McCullough, Matthew

    2013-09-20

    Any new scalar fields that perturbatively solve the hierarchy problem by stabilizing the Higgs boson mass also generate new contributions to the Higgs boson field-strength renormalization, irrespective of their gauge representation. These new contributions are physical, and in explicit models their magnitude can be inferred from the requirement of quadratic divergence cancellation; hence, they are directly related to the resolution of the hierarchy problem. Upon canonically normalizing the Higgs field, these new contributions lead to modifications of Higgs couplings that are typically great enough that the hierarchy problem and the concept of electroweak naturalness can be probed thoroughly within a precision Higgs boson program. Specifically, at a lepton collider this can be achieved through precision measurements of the Higgs boson associated production cross section. This would lead to indirect constraints on perturbative solutions to the hierarchy problem in the broadest sense, even if the relevant new fields are gauge singlets.

  5. Advanced Langmuir Probe (LP)

    Science.gov (United States)

    Voronka, N. R.; Block, B. P.; Carignan, G. R.

    1991-01-01

    The dynamic response of the MK-2 version of the Langmuir probe amplifier was studied. The settling time of the step response is increased by: (1) stray node-to-ground capacitance at series connections between high value feedback resistors; and (2) input capacitance due to the input cable, FET switches, and input source follower. The stray node-to-ground capacitances can be reduced to tolerable levels by elevating the string of feedback resistors above the printing board. A new feedback network was considered, with promising results. The design uses resistances having much lower nominal values, thereby minimizing the effect of stray capacitances. Faster settling times can be achieved by using an operational amplifier having a higher gain-bandwidth product.

  6. Differential Reinforcement of Correct Responses to Probes and Prompts in Picture-Name Training with Severely Retarded Children.

    Science.gov (United States)

    Olenick, Debra L.; Pear, Joseph J.

    1980-01-01

    A systematic sequence of prompt and probe trials was used to teach picture names to three severely retarded children (aged 4). For all children the fixed ratio schedule for correct responses to prompts, combined with the every correct response reinforced schedule for correct responses to probes, generated the best results. (Author/PHR)

  7. Synthesis of Photoactivatable Phospholipidic Probes

    Institute of Scientific and Technical Information of China (English)

    Qing PENG; Fan Qi QU; Yi XIA; Jie Hua ZHOU; Qiong You WU; Ling PENG

    2005-01-01

    We synthesized and characterized photoactivatable phospholipidic probes 1-3. These probes have the perfluorinated aryl azide function at the polar head of phospholipid. They are stable in dark and become highly reactive upon photoirradiation. The preliminary results suggest that they are promising tools to study the topology of membrane proteins and protein-lipid interactions using photolabeling approach.

  8. Non-inductive current probe

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl

    1977-01-01

    The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is......The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is...

  9. Cobra Probes Containing Replaceable Thermocouples

    Science.gov (United States)

    Jones, John; Redding, Adam

    2007-01-01

    A modification of the basic design of cobra probes provides for relatively easy replacement of broken thermocouples. Cobra probes are standard tube-type pressure probes that may also contain thermocouples and that are routinely used in wind tunnels and aeronautical hardware. They are so named because in side views, they resemble a cobra poised to attack. Heretofore, there has been no easy way to replace a broken thermocouple in a cobra probe: instead, it has been necessary to break the probe apart and then rebuild it, typically at a cost between $2,000 and $4,000 (2004 prices). The modified design makes it possible to replace the thermocouple, in minimal time and at relatively low cost, by inserting new thermocouple wire in a tube.

  10. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    silicon processing. Using a microgripper they were detached from an array and fixed to a standard pyramidal AFM probe or alternatively inserted into a tipless cantilever equipped with a narrow slit. The nanobit-enhanced probes were used for imaging of deep trenches, without visible deformation, wear......We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard...... or dislocation of the tips of the nanobit after several scans. This approach allows an unprecedented freedom in adapting the shape and size of scanning probe tips to the surface topology or to the specific application....

  11. Wearable probes for service design

    DEFF Research Database (Denmark)

    Mullane, Aaron; Laaksolahti, Jarmo Matti; Svanæs, Dag

    2014-01-01

    by service employees in reflecting on the delivery of a service. In this paper, we present the ‘wearable probe’, a probe concept that captures sensor data without distracting service employees. Data captured by the probe can be used by the service employees to reflect and co-reflect on the service journey......Probes are used as a design method in user-centred design to allow end-users to inform design by collecting data from their lives. Probes are potentially useful in service innovation, but current probing methods require users to interrupt their activity and are consequently not ideal for use......, helping to identify opportunities for service evolution and innovation....

  12. Electrophoresis-mass spectrometry probe

    Science.gov (United States)

    Andresen, Brian D.; Fought, Eric R.

    1987-01-01

    The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface.

  13. Mobile Probes in Mobile Learning

    DEFF Research Database (Denmark)

    Ørngreen, Rikke; Blomhøj, Ulla; Duvaa, Uffe

    as an agent for acquiring empirical data (as the situation in hitherto mobile probe settings) but was also the technological medium for which data should say something about (mobile learning). Consequently, not only the content of the data but also the ways in which data was delivered and handled, provided......In this paper experiences from using mobile probes in educational design of a mobile learning application is presented. The probing process stems from the cultural probe method, and was influenced by qualitative interview and inquiry approaches. In the project, the mobile phone was not only acting...... a valuable dimension for investigating mobile use. The data was collected at the same time as design activities took place and the collective data was analysed based on user experience goals and cognitive processes from interaction design and mobile learning. The mobile probe increased the knowledge base...

  14. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... treatment, screening, diagnostic, prevention, and supportive care trials. Treatment Trials In treatment trials, researchers may gather information about experimental treatments, ...

  15. The Trial

    Science.gov (United States)

    Bryant, Jen

    2004-01-01

    Growing up in Flemington, New Jersey, put Jen Bryant in the heart of the lore behind the Lindbergh baby kidnapping. Family stories of the events of the day and extensive research led to "The Trial," a novel in verse. The first several parts of this novel are included here.

  16. Exact probes of orientifolds

    CERN Document Server

    Fiol, Bartomeu; Torrents, Genis

    2014-01-01

    We compute the exact vacuum expectation value of circular Wilson loops for Euclidean ${\\cal N}=4$ super Yang-Mills with $G=SO(N),Sp(N)$, in the fundamental and spinor representations. These field theories are dual to type IIB string theory compactified on $AdS_5\\times {\\mathbb R} {\\mathbb P}^5$ plus certain choices of discrete torsion, and we use our results to probe this holographic duality. We first revisit the LLM-type geometries having $AdS_5\\times {\\mathbb R} {\\mathbb P}^5$ as ground state. Our results clarify and refine the identification of these LLM-type geometries as bubbling geometries arising from fermions on a half harmonic oscillator. We furthermore identify the presence of discrete torsion with the one-fermion Wigner distribution becoming negative at the origin of phase space. We then turn to the string world-sheet interpretation of our results and argue that for the quantities considered they imply two features: first, the contribution coming from world-sheets with a single crosscap is closely ...

  17. Steerable Doppler transducer probes

    Energy Technology Data Exchange (ETDEWEB)

    Fidel, H.F.; Greenwood, D.L.

    1986-07-22

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis.

  18. Transient Astrophysics Probe

    Science.gov (United States)

    Camp, Jordan

    2017-08-01

    Transient Astrophysics Probe (TAP), selected by NASA for a funded Concept Study, is a wide-field high-energy transient mission proposed for flight starting in the late 2020s. TAP’s main science goals, called out as Frontier Discovery areas in the 2010 Decadal Survey, are time-domain astrophysics and counterparts of gravitational wave (GW) detections. The mission instruments include unique imaging soft X-ray optics that allow ~500 deg2 FoV in each of four separate modules; a high sensitivity, 1 deg2 FoV soft X-ray telescope based on single crystal silicon optics; a passively cooled, 1 deg2 FoV Infrared telescope with bandpass 0.6-3 micron; and a set of ~8 small NaI gamma-ray detectors. TAP will observe many events per year of X-ray transients related to compact objects, including tidal disruptions of stars, supernova shock breakouts, neutron star bursts and superbursts, and high redshift Gamma-Ray Bursts. Perhaps most exciting is TAP’s capability to observe X-ray and IR counterparts of GWs involving stellar mass black holes detected by LIGO/Virgo, and possibly X-ray counterparts of GWs from supermassive black holes, detected by LISA and Pulsar Timing Arrays.

  19. A subcutaneous Raman needle probe.

    Science.gov (United States)

    Day, John C C; Stone, Nicholas

    2013-03-01

    Raman spectroscopy is a powerful tool for studying the biochemical composition of tissues and cells in the human body. We describe the initial results of a feasibility study to design and build a miniature, fiber optic probe incorporated into a standard hypodermic needle. This probe is intended for use in optical biopsies of solid tissues to provide valuable information of disease type, such as in the lymphatic system, breast, or prostate, or of such tissue types as muscle, fat, or spinal, when identifying a critical injection site. The optical design and fabrication of this probe is described, and example spectra of various ex vivo samples are shown.

  20. Subminiature Hot-Wire Probes

    Science.gov (United States)

    Westphal, R. V.; Lemos, F. R.; Ligrani, P. M.

    1989-01-01

    Class of improved subminiature hot-wire flow-measuring probes developed. Smaller sizes yield improved resolution in measurements of practical aerodynamic flows. Probe made in one-wire, two-perpendicular-wire, and three-perpendicular-wire version for measurement of one, two, or all three components of flow. Oriented and positioned on micromanipulator stage and viewed under microscope during fabrication. Tested by taking measurements in constant-pressure turbulent boundary layer. New probes give improved measurements of turbulence quantities near surfaces and anisotropies of flows strongly influence relative errors caused by phenomena related to spatial resolution.

  1. Optic probe for semiconductor characterization

    Science.gov (United States)

    Sopori, Bhushan L.; Hambarian, Artak

    2008-09-02

    Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).

  2. What Are Clinical Trials?

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Clinical Trials What Are Clinical Trials? Past Issues / Fall 2010 Table of Contents Clinical ... conducted all the time. The Different Phases of Clinical Trials Clinical trials related to drugs are classified into ...

  3. Participating in Clinical Trials

    Science.gov (United States)

    ... this page please turn Javascript on. Participating in Clinical Trials About Clinical Trials A Research Study With Human Subjects A clinical ... to treat or cure a disease. Phases of Clinical Trials Clinical trials of drugs are usually described based ...

  4. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... Usually, trial participants must show signs of the disease or condition before they can join this type of trial. Prevention Trials Click for more information In prevention trials, ...

  5. {beta} - amyloid imaging probes

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jae Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2007-04-15

    Imaging distribution of {beta} - amyloid plaques in Alzheimer's disease is very important for early and accurate diagnosis. Early trial of the {beta} -amyloid plaques includes using radiolabeled peptides which can be only applied for peripheral {beta} - amyloid plaques due to limited penetration through the blood brain barrier (BBB). Congo red or Chrysamine G derivatives were labeled with Tc-99m for imaging {beta} - amyloid plaques of Alzheimer patient's brain without success due to problem with BBB penetration. Thioflavin T derivatives gave breakthrough for {beta} - amyloid imaging in vivo, and a benzothiazole derivative [C-11]6-OH-BTA-1 brought a great success. Many other benzothiazole, benzoxazole, benzofuran, imidazopyridine, and styrylbenzene derivatives have been labeled with F-18 and I-123 to improve the imaging quality. However, [C-11]6-OH-BTA-1 still remains as the best. However, short half-life of C-11 is a limitation of wide distribution of this agent. So, it is still required to develop an Tc-99m, F-18 or I-123 labeled agent for {beta} - amyloid imaging agent.

  6. Small Probe Reentry System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Global Aerospace Corporation (GAC), and its research partner, Cal Poly San Luis Obispo (CPSLO), will develop an integrated Small Probe Reentry System (SPRS) for low...

  7. Lunar Probe Reaches Deep Space

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    @@ China's second lunar probe, Chang'e-2, has reached an orbit 1.5 million kilometers from Earth for an additional mission of deep space exploration, the State Administration for Science, Technology and Industry for National Defense announced.

  8. DNA probe for lactobacillus delbrueckii

    Energy Technology Data Exchange (ETDEWEB)

    Delley, M.; Mollet, B.; Hottinger, H. (Nestle Research Centre, Lausanne (Switzerland))

    1990-06-01

    From a genomic DNA library of Lactobacillus delbrueckii subsp. bulgaricus, a clone was isolated which complements a leucine auxotrophy of an Escherichia coli strain (GE891). Subsequent analysis of the clone indicated that it could serve as a specific DNA probe. Dot-blot hybridizations with over 40 different Lactobacillus strains showed that this clone specifically recognized L. delbrueckii subsp. delbrueckii, bulgaricus, and lactis. The sensitivity of the method was tested by using an {alpha}-{sup 32}P-labeled probe.

  9. Transformer-coupled NMR probe

    Science.gov (United States)

    Utsuzawa, Shin; Mandal, Soumyajit; Song, Yi-Qiao

    2012-03-01

    In this study, we propose an NMR probe circuit that uses a transformer with a ferromagnetic core for impedance matching. The ferromagnetic core provides a strong but confined coupling that result in efficient energy transfer between the sample coil and NMR spectrometer, while not disturbing the B1 field generated by the sample coil. We built a transformer-coupled NMR probe and found that it offers comparable performance (loss NQR.

  10. IVVS probe mechanical concept design

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it; Neri, Carlo; De Collibus, Mario Ferri; Mugnaini, Giampiero; Pollastrone, Fabio; Crescenzi, Fabio

    2015-10-15

    Highlights: • ENEA designed, developed and tested a laser based In Vessel Viewing System (IVVS). • IVVS mechanical design has been revised from 2011 to 2013 to meet ITER requirements. • Main improvements are piezoceramic actuators and a step focus system. • Successful qualification activities validated the concept design for ITER environment. - Abstract: ENEA has been deeply involved in the design, development and testing of a laser based In Vessel Viewing System (IVVS) required for the inspection of ITER plasma-facing components. The IVVS probe shall be deployed into the vacuum vessel, providing high resolution images and metrology measurements to detect damages and possible erosion. ENEA already designed and manufactured an IVVS probe prototype based on a rad-hard concept and driven by commercial micro-step motors, which demonstrated satisfying viewing and metrology performances at room conditions. The probe sends a laser beam through a reflective rotating prism. By rotating the axes of the prism, the probe can scan all the environment points except those present in a shadow cone and the backscattered light signal is then processed to measure the intensity level (viewing) and the distance from the probe (metrology). During the last years, in order to meet all the ITER environmental conditions, such as high vacuum, gamma radiation lifetime dose up to 5 MGy, cumulative neutron fluence of about 2.3 × 10{sup 17} n/cm{sup 2}, temperature of 120 °C and magnetic field of 8 T, the probe mechanical design was significantly revised introducing a new actuating system based on piezo-ceramic actuators and improved with a new step focus system. The optical and mechanical schemes have been then modified and refined to meet also the geometrical constraints. The paper describes the mechanical concept design solutions adopted in order to fulfill IVVS probe functional performance requirements considering ITER working environment and geometrical constraints.

  11. Multiple-probe scanning probe microscopes for nanoarchitectonic materials science

    Science.gov (United States)

    Nakayama, Tomonobu; Shingaya, Yoshitaka; Aono, Masakazu

    2016-11-01

    Nanoarchitectonic systems are of interest for utilizing a vast range of nanoscale materials for future applications requiring a huge number of elemental nanocomponents. To explore the science and technology of nanoarchitectonics, advanced characterization tools that can deal with both nanoscale objects and macroscopically extended nanosystems are demanded. Multiple-probe scanning probe microscopes (MP-SPMs) are powerful tools that meet this demand because they take the advantages of conventional scanning probe microscopes and realize atomically precise electrical measurements, which cannot be done with conventional microprobing systems widely used in characterizing materials and devices. Furthermore, an MP-SPM can be used to operate some nanoarchitectonic systems. In this review, we overview the indispensable features of MP-SPMs together with the past, present and future of MP-SPM technology.

  12. Meta-analysis of five photodisinfection clinical trials for periodontitis

    Science.gov (United States)

    Andersen, Roger C.; Loebel, Nicolas G.; Andersen, Dane M.

    2009-06-01

    Photodynamic therapy(PDT) has been demonstrated to effectively kill human periopathogens in vitro. To evaluate the efficacy of PDT in vivo a series of clinical trials was carried out in multiple centers and populations. Clinical parameters including clinical attachment level, pocket probing depth and bleeding on probing were all evaluated. All groups received the standard of care, scaling and root planing, and the treatment group additionally received a single treatment of PDT. Of the total 309 patients and over 40,000 pockets treated in these 5 trials it was determined that photodynamic therapy provided a statistically significant improvement in clinical parameters over scaling and root planing alone.

  13. Optical imaging probes in oncology.

    Science.gov (United States)

    Martelli, Cristina; Lo Dico, Alessia; Diceglie, Cecilia; Lucignani, Giovanni; Ottobrini, Luisa

    2016-07-26

    Cancer is a complex disease, characterized by alteration of different physiological molecular processes and cellular features. Keeping this in mind, the possibility of early identification and detection of specific tumor biomarkers by non-invasive approaches could improve early diagnosis and patient management.Different molecular imaging procedures provide powerful tools for detection and non-invasive characterization of oncological lesions. Clinical studies are mainly based on the use of computed tomography, nuclear-based imaging techniques and magnetic resonance imaging. Preclinical imaging in small animal models entails the use of dedicated instruments, and beyond the already cited imaging techniques, it includes also optical imaging studies. Optical imaging strategies are based on the use of luminescent or fluorescent reporter genes or injectable fluorescent or luminescent probes that provide the possibility to study tumor features even by means of fluorescence and luminescence imaging. Currently, most of these probes are used only in animal models, but the possibility of applying some of them also in the clinics is under evaluation.The importance of tumor imaging, the ease of use of optical imaging instruments, the commercial availability of a wide range of probes as well as the continuous description of newly developed probes, demonstrate the significance of these applications. The aim of this review is providing a complete description of the possible optical imaging procedures available for the non-invasive assessment of tumor features in oncological murine models. In particular, the characteristics of both commercially available and newly developed probes will be outlined and discussed.

  14. Types of Treatment: Clinical Trials

    Science.gov (United States)

    ... Disease Information Treatment Types of Treatment Clinical Trials Clinical Trials Clinical Trials SHARE: Print Glossary Taking part in a clinical ... for cancer are based on previous clinical trials. Clinical Trial Service: LLS provides personalized clinical trial navigation when ...

  15. Spaser as a biological probe

    Science.gov (United States)

    Galanzha, Ekaterina I.; Weingold, Robert; Nedosekin, Dmitry A.; Sarimollaoglu, Mustafa; Nolan, Jacqueline; Harrington, Walter; Kuchyanov, Alexander S.; Parkhomenko, Roman G.; Watanabe, Fumiya; Nima, Zeid; Biris, Alexandru S.; Plekhanov, Alexander I.; Stockman, Mark I.; Zharov, Vladimir P.

    2017-06-01

    Understanding cell biology greatly benefits from the development of advanced diagnostic probes. Here we introduce a 22-nm spaser (plasmonic nanolaser) with the ability to serve as a super-bright, water-soluble, biocompatible probe capable of generating stimulated emission directly inside living cells and animal tissues. We have demonstrated a lasing regime associated with the formation of a dynamic vapour nanobubble around the spaser that leads to giant spasing with emission intensity and spectral width >100 times brighter and 30-fold narrower, respectively, than for quantum dots. The absorption losses in the spaser enhance its multifunctionality, allowing for nanobubble-amplified photothermal and photoacoustic imaging and therapy. Furthermore, the silica spaser surface has been covalently functionalized with folic acid for molecular targeting of cancer cells. All these properties make a nanobubble spaser a promising multimodal, super-contrast, ultrafast cellular probe with a single-pulse nanosecond excitation for a variety of in vitro and in vivo biomedical applications.

  16. Sensor probe for rectal manometry

    Energy Technology Data Exchange (ETDEWEB)

    Blechschmidt, R.A.; Hohlfeld, O.; Mueller, R.; Werthschuetzky, R. [Technische Univ. Darmstadt (Germany). Inst. fuer Elektromechanische Konstruktionen

    2001-07-01

    In this paper a pressure sensor probe is presented that is suitable for assessing dynamic rectal pressure profiles. It consists of ten piezoresistive sensors, mounted on low temperature co-fired ceramics. The sensors are coated with a bio-compatible silicone elastomer. It was possible to reduce the size of the ceramic to 4.5 x 5.5 mm with a height of 1.4 mm. The whole probe has a diameter of 9 mm and a length of 20 cm. One healthy test person underwent rectal manometry. The experimental data and the analysis of linearity, hysteresis, temperature stability, and reproducibility are discussed. The presented sensor probe extends the classical anorectal manometry, particularly in view of quantifying disorders of the rectal motility. (orig.)

  17. Probing of Nascent Riboswitch Transcripts.

    Science.gov (United States)

    Chauvier, Adrien; Lafontaine, Daniel A

    2015-01-01

    The study of biologically significant and native structures is vital to characterize RNA-based regulatory mechanisms. Riboswitches are cis-acting RNA molecules that are involved in the biosynthesis and transport of cellular metabolites. Because riboswitches regulate gene expression by modulating their structure, it is vital to employ native probing assays to determine how native riboswitch structures perform highly efficient and specific ligand recognition. By employing RNase H probing, it is possible to determine the accessibility of specific RNA domains in various structural contexts. Herein, we describe how to employ RNase H probing to characterize nascent mRNA riboswitch molecules as a way to obtain information regarding the riboswitch regulation control mechanism.

  18. Hand-held survey probe

    Science.gov (United States)

    Young, Kevin L [Idaho Falls, ID; Hungate, Kevin E [Idaho Falls, ID

    2010-02-23

    A system for providing operational feedback to a user of a detection probe may include an optical sensor to generate data corresponding to a position of the detection probe with respect to a surface; a microprocessor to receive the data; a software medium having code to process the data with the microprocessor and pre-programmed parameters, and making a comparison of the data to the parameters; and an indicator device to indicate results of the comparison. A method of providing operational feedback to a user of a detection probe may include generating output data with an optical sensor corresponding to the relative position with respect to a surface; processing the output data, including comparing the output data to pre-programmed parameters; and indicating results of the comparison.

  19. All-Fiber Raman Probe

    DEFF Research Database (Denmark)

    Brunetti, Anna Chiara

    The design and development of an all-in-fiber probe for Raman spectroscopy are presented in this Thesis. Raman spectroscopy is an optical technique able to probe a sample based on the inelastic scattering of monochromatic light. Due to its high specificity and reliability and to the possibility...... to perform real-time measurements with little or no sample preparation, Raman spectroscopy is now considered an invaluable analytical tool, finding application in several fields including medicine, defense and process control. When combined with fiber optics technology, Raman spectroscopy allows...... for the realization of flexible and minimally-invasive devices, able to reach remote or hardly accessible samples, and to perform in-situ analyses in hazardous environments. The work behind this Thesis focuses on the proof-of-principle demonstration of a truly in-fiber Raman probe, where all parts are realized...

  20. A Pan-GTPase Inhibitor as a Molecular Probe.

    Science.gov (United States)

    Hong, Lin; Guo, Yuna; BasuRay, Soumik; Agola, Jacob O; Romero, Elsa; Simpson, Denise S; Schroeder, Chad E; Simons, Peter; Waller, Anna; Garcia, Matthew; Carter, Mark; Ursu, Oleg; Gouveia, Kristine; Golden, Jennifer E; Aubé, Jeffrey; Wandinger-Ness, Angela; Sklar, Larry A

    2015-01-01

    Overactive GTPases have often been linked to human diseases. The available inhibitors are limited and have not progressed far in clinical trials. We report here a first-in-class small molecule pan-GTPase inhibitor discovered from a high throughput screening campaign. The compound CID1067700 inhibits multiple GTPases in biochemical, cellular protein and protein interaction, as well as cellular functional assays. In the biochemical and protein interaction assays, representative GTPases from Rho, Ras, and Rab, the three most generic subfamilies of the GTPases, were probed, while in the functional assays, physiological processes regulated by each of the three subfamilies of the GTPases were examined. The chemical functionalities essential for the activity of the compound were identified through structural derivatization. The compound is validated as a useful molecular probe upon which GTPase-targeting inhibitors with drug potentials might be developed.

  1. A Pan-GTPase Inhibitor as a Molecular Probe.

    Directory of Open Access Journals (Sweden)

    Lin Hong

    Full Text Available Overactive GTPases have often been linked to human diseases. The available inhibitors are limited and have not progressed far in clinical trials. We report here a first-in-class small molecule pan-GTPase inhibitor discovered from a high throughput screening campaign. The compound CID1067700 inhibits multiple GTPases in biochemical, cellular protein and protein interaction, as well as cellular functional assays. In the biochemical and protein interaction assays, representative GTPases from Rho, Ras, and Rab, the three most generic subfamilies of the GTPases, were probed, while in the functional assays, physiological processes regulated by each of the three subfamilies of the GTPases were examined. The chemical functionalities essential for the activity of the compound were identified through structural derivatization. The compound is validated as a useful molecular probe upon which GTPase-targeting inhibitors with drug potentials might be developed.

  2. Probe Project Status and Accomplishments

    Energy Technology Data Exchange (ETDEWEB)

    Burris, RD

    2001-05-07

    The Probe project has completed its first full year of operation. In this document we will describe the status of the project as of December 31, 2000. We will describe the equipment configuration, then give brief descriptions of the various projects undertaken to date. We will mention first those projects performed for outside entities and then those performed for the benefit of one of the Probe sites. We will then describe projects that are under consideration, including some for which initial actions have been taken and others which are somewhat longer-term.

  3. Radioactive Probes on Ferromagnetic Surfaces

    CERN Multimedia

    2002-01-01

    On the (broad) basis of our studies of nonmagnetic radioactive probe atoms on magnetic surfaces and at interfaces, we propose to investigate the magnetic interaction of magnetic probe atoms with their immediate environment, in particular of rare earth (RE) elements positioned on and in ferromagnetic surfaces. The preparation and analysis of the structural properties of such samples will be performed in the UHV chamber HYDRA at the HMI/Berlin. For the investigations of the magnetic properties of RE atoms on surfaces Perturbed Angular Correlation (PAC) measurements and Mössbauer Spectroscopy (MS) in the UHV chamber ASPIC (Apparatus for Surface Physics and Interfaces at CERN) are proposed.

  4. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... trial is to find out if an experimental drug, therapy, medical device, lifestyle change, or test will ... disease. Phases of Clinical Trials Clinical trials of drugs are usually described based on their phase. The ...

  5. Electroless nickel plating on optical fiber probe

    Institute of Scientific and Technical Information of China (English)

    Li Huang; Zhoufeng Wang; Zhuomin Li; Wenli Deng

    2009-01-01

    As a component of near-field scanning optical microscope (NSOM),optical fiber probe is an important factor influncing the equipment resolution.Electroless nickel plating is introduced to metallize the optical fiber probe.The optical fibers are etched by 40% HF with Turner etching method.Through pretreatment,the optical fiber probe is coated with Ni-P film by clectrolcss plating in a constant temperature water tank.Atomic absorption spectrometry (AAS),scanning electron microscopy (SEM),and energy dispersive X-ray spectrometry (EDXS) are carried out to charaeterizc the deposition on fiber probe.We have rcproducibly fabricated two kinds of fiber probes with a Ni-P fihn:aperture probe and apertureless probe.In addition,reductive particle transportation on the surface of fiber probe is proposed to explain the cause of these probes.

  6. Characterization of near-field optical probes

    DEFF Research Database (Denmark)

    Vohnsen, Brian; Bozhevolnyi, Sergey I.

    1999-01-01

    Radiation and collection characteristics of four different near-field optical-fiber probes, namely, three uncoated probes and an aluminium-coated small-aperture probe, are investigated and compared. Their radiation properties are characterized by observation of light-induced topography changes...... in a photo-sensitive film illuminated with the probes, and it is confirmed that the radiated optical field is unambigiously confined only for the coated probe. Near-field optical imaging of a standing evanescent-wave pattern is used to compare the detection characteristics of the probes, and it is concluded...... that, for the imaging of optical-field intensity distributions containing predominantly evanescent-wave components, a sharp uncoated tip is the probe of choice. Complementary results obtained with optical phase-conjugation experiments with he uncoated probes are discussed in relation to the probe...

  7. A fluorescent probe for ecstasy.

    Science.gov (United States)

    Masseroni, D; Biavardi, E; Genovese, D; Rampazzo, E; Prodi, L; Dalcanale, E

    2015-08-18

    A nanostructure formed by the insertion in silica nanoparticles of a pyrene-derivatized cavitand, which is able to specifically recognize ecstasy in water, is presented. The absence of effects from interferents and an efficient electron transfer process occurring after complexation of ecstasy, makes this system an efficient fluorescent probe for this popular drug.

  8. Health. CEM Probe, January 1977.

    Science.gov (United States)

    Billington, Roy

    The importance of health and its relationship to personal and community life are explored in this issue of PROBE. Designed to acquaint British secondary school youth with topical problems, the series contains discussion and case studies of national and world issues, followed by questions for student discussion and research. Nine chapters comprise…

  9. Extensive Extinction in Multiple Contexts Eliminates the Renewal of Conditioned Fear in Rats

    Science.gov (United States)

    Thomas, Brian L.; Vurbic, Drina; Novak, Cheryl

    2009-01-01

    Two studies examined whether nonreinforcement of a stimulus in multiple contexts, instead of a single context, would decrease renewal of conditioned fear in rats (as assessed by conditioned suppression of lever pressing). In Experiment 1, renewal was measured after 36 nonreinforced CS trials delivered during six extinction sessions in a single…

  10. High pressure optical combustion probe

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, S.D.; Richards, G.A.

    1995-06-01

    The Department of Energy`s Morgantown Energy Technology Center has developed a combustion probe for monitoring flame presence and heat release. The technology involved is a compact optical detector of the OH radical`s UV fluorescence. The OH Monitor/Probe is designed to determine the flame presence and provide a qualitative signal proportional to the flame intensity. The probe can be adjusted to monitor a specific volume in the combustion zone to track spatial fluctuations in the flame. The probe is capable of nanosecond time response and is usually slowed electronically to fit the flame characteristics. The probe is a sapphire rod in a stainless steel tube which may be inserted into the combustion chamber and pointed at the flame zone. The end of the sapphire rod is retracted into the SS tube to define a narrow optical collection cone. The collection cone may be adjusted to fit the experiment. The fluorescence signal is collected by the sapphire rod and transmitted through a UV transmitting, fused silica, fiber optic to the detector assembly. The detector is a side window photomultiplier (PMT) with a 310 run line filter. A Hamamatsu photomultiplier base combined with a integral high voltage power supply permits this to be a low voltage device. Electronic connections include: a power lead from a modular DC power supply for 15 VDC; a control lead for 0-1 volts to control the high voltage level (and therefore gain); and a lead out for the actual signal. All low voltage connections make this a safe and easy to use device while still delivering the sensitivity required.

  11. Cantilevered probe detector with piezoelectric element

    Science.gov (United States)

    Adams, Jesse D; Sulchek, Todd A; Feigin, Stuart C

    2013-04-30

    A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

  12. Overview of Probe-based Storage Technologies

    Science.gov (United States)

    Wang, Lei; Yang, Ci Hui; Wen, Jing; Gong, Si Di; Peng, Yuan Xiu

    2016-07-01

    The current world is in the age of big data where the total amount of global digital data is growing up at an incredible rate. This indeed necessitates a drastic enhancement on the capacity of conventional data storage devices that are, however, suffering from their respective physical drawbacks. Under this circumstance, it is essential to aggressively explore and develop alternative promising mass storage devices, leading to the presence of probe-based storage devices. In this paper, the physical principles and the current status of several different probe storage devices, including thermo-mechanical probe memory, magnetic probe memory, ferroelectric probe memory, and phase-change probe memory, are reviewed in details, as well as their respective merits and weakness. This paper provides an overview of the emerging probe memories potentially for next generation storage device so as to motivate the exploration of more innovative technologies to push forward the development of the probe storage devices.

  13. Where do pulse oximeter probes break?

    Science.gov (United States)

    Crede, S; Van der Merwe, G; Hutchinson, J; Woods, D; Karlen, W; Lawn, J

    2014-06-01

    Pulse oximetry, a non-invasive method for accurate assessment of blood oxygen saturation (SPO2), is an important monitoring tool in health care facilities. However, it is often not available in many low-resource settings, due to expense, overly sophisticated design, a lack of organised procurement systems and inadequate medical device management and maintenance structures. Furthermore medical devices are often fragile and not designed to withstand the conditions of low-resource settings. In order to design a probe, better suited to the needs of health care facilities in low-resource settings this study aimed to document the site and nature of pulse oximeter probe breakages in a range of different probe designs in a low to middle income country. A retrospective review of job cards relating to the assessment and repair of damaged or faulty pulse oximeter probes was conducted at a medical device repair company based in Cape Town, South Africa, specializing in pulse oximeter probe repairs. 1,840 job cards relating to the assessment and repair of pulse oximeter probes were reviewed. 60.2 % of probes sent for assessment were finger-clip probes. For all probes, excluding the neonatal wrap probes, the most common point of failure was the probe wiring (>50 %). The neonatal wrap most commonly failed at the strap (51.5 %). The total cost for quoting on the broken pulse oximeter probes and for the subsequent repair of devices, excluding replacement components, amounted to an estimated ZAR 738,810 (USD $98,508). Improving the probe wiring would increase the life span of pulse oximeter probes. Increasing the life span of probes will make pulse oximetry more affordable and accessible. This is of high priority in low-resource settings where frequent repair or replacement of probes is unaffordable or impossible.

  14. Probing zeolites by vibrational spectroscopies.

    Science.gov (United States)

    Bordiga, Silvia; Lamberti, Carlo; Bonino, Francesca; Travert, Arnaud; Thibault-Starzyk, Frédéric

    2015-10-21

    This review addresses the most relevant aspects of vibrational spectroscopies (IR, Raman and INS) applied to zeolites and zeotype materials. Surface Brønsted and Lewis acidity and surface basicity are treated in detail. The role of probe molecules and the relevance of tuning both the proton affinity and the steric hindrance of the probe to fully understand and map the complex site population present inside microporous materials are critically discussed. A detailed description of the methods needed to precisely determine the IR absorption coefficients is given, making IR a quantitative technique. The thermodynamic parameters of the adsorption process that can be extracted from a variable-temperature IR study are described. Finally, cutting-edge space- and time-resolved experiments are reviewed. All aspects are discussed by reporting relevant examples. When available, the theoretical literature related to the reviewed experimental results is reported to support the interpretation of the vibrational spectra on an atomic level.

  15. Metalloprotein-based MRI probes.

    Science.gov (United States)

    Matsumoto, Yuri; Jasanoff, Alan

    2013-04-17

    Metalloproteins have long been recognized as key determinants of endogenous contrast in magnetic resonance imaging (MRI) of biological subjects. More recently, both natural and engineered metalloproteins have been harnessed as biotechnological tools to probe gene expression, enzyme activity, and analyte concentrations by MRI. Metalloprotein MRI probes are paramagnetic and function by analogous mechanisms to conventional gadolinium or iron oxide-based MRI contrast agents. Compared with synthetic agents, metalloproteins typically offer worse sensitivity, but the possibilities of using protein engineering and targeted gene expression approaches in conjunction with metalloprotein contrast agents are powerful and sometimes definitive strengths. This review summarizes theoretical and practical aspects of metalloprotein-based contrast agents, and discusses progress in the exploitation of these proteins for molecular imaging applications.

  16. Clinical Trials in Vision Research

    Science.gov (United States)

    ... Eye Health Information > Clinical Trials in Vision Research Clinical Trials in Vision Research Clinical studies depend on people ... vision research in the United States. Basics of Clinical Trials What is a clinical trial? Clinical trials are ...

  17. How Do Clinical Trials Work?

    Science.gov (United States)

    ... Studies NHLBI Trials Clinical Trial Websites How Do Clinical Trials Work? If you take part in a clinical ... protect patients and help produce reliable study results. Clinical Trial Protocol Each clinical trial has a master plan ...

  18. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... trial. Prevention Trials Click for more information In prevention trials, researchers study ways to reduce the risk of getting a disease or a specific medical problem. These trials find out if lifestyle changes, such as exercising more, getting more sleep, ...

  19. Distance probes of dark energy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, A. G.; Padmanabhan, N.; Aldering, G.; Allen, S. W.; Baltay, C.; Cahn, R. N.; D’Andrea, C. B.; Dalal, N.; Dawson, K. S.; Denney, K. D.; Eisenstein, D. J.; Finley, D. A.; Freedman, W. L.; Ho, S.; Holz, D. E.; Kasen, D.; Kent, S. M.; Kessler, R.; Kuhlmann, S.; Linder, E. V.; Martini, P.; Nugent, P. E.; Perlmutter, S.; Peterson, B. M.; Riess, A. G.; Rubin, D.; Sako, M.; Suntzeff, N. V.; Suzuki, N.; Thomas, R. C.; Wood-Vasey, W. M.; Woosley, S. E.

    2015-03-01

    This document presents the results from the Distances subgroup of the Cosmic Frontier Community Planning Study (Snowmass 2013). We summarize the current state of the field as well as future prospects and challenges. In addition to the established probes using Type Ia supernovae and baryon acoustic oscillations, we also consider prospective methods based on clusters, active galactic nuclei, gravitational wave sirens and strong lensing time delays.

  20. Probing the Tautomerism of Histidine

    Science.gov (United States)

    Bermudez, C.; Cabezas, C.; Mata, S.; Alonso, J. L.

    2013-06-01

    The rotational spectrum of histidine, showing a complex nuclear quadrupole interactions arising from three ^{14}N nuclei in non-equivalent positions have been resolved and completely analyzed. Solid samples (m.p. 290°C) were vaporized by laser ablation and probed by Fourier transform microwave spectroscopy in a supersonic expansion. The experimental constants clearly lead to the unambiguous identification of the \\varepsilon tautomer in the gas phase.

  1. Distance Probes of Dark Energy

    CERN Document Server

    Kim, A; Aldering, G; Allen, S; Baltay, C; Cahn, R; D'Andrea, C; Dalal, N; Dawson, K; Denney, K; Eisenstein, D; Finley, D; Freedman, W; Ho, S; Holz, D; Kent, A; Kasen, D; Kessler, R; Kuhlmann, S; Linder, E; Martini, P; Nugent, P; Perlmutter, S; Peterson, B; Riess, A; Rubin, D; Sako, M; Suntzeff, N; Suzuki, N; Thomas, R; Wood-Vasey, W M; Woosley, S

    2013-01-01

    This document presents the results from the Distances subgroup of the Cosmic Frontier Community Planning Study (Snowmass 2013). We summarize the current state of the field as well as future prospects and challenges. In addition to the established probes using Type IA supernovae and baryon acoustic oscillations, we also consider prospective methods based on clusters, active galactic nuclei, gravitational wave sirens and strong lensing time delays.

  2. Chemomechanics with Molecular Force Probes

    Science.gov (United States)

    2010-03-30

    probe should have [25,26]: (1) a size that is small enough to allow high-level quantum -chemical calcu- lations of geometries and energies of...macrocycles makes them amenable to high-level quantum -chemical calculations, which yield restoring forces without the ambi- guities intrinsic to...reactions to be measured and in- terpreted structurally and mechanistically by integrating molecular design, synthesis, kinetic/ mechanis - tic studies and

  3. Flying Probe Tester: Architecture, Principle and Implementation

    Institute of Scientific and Technical Information of China (English)

    Fu,Xu; Fang,Kangling; Chen,Guoqing

    2005-01-01

    This paper introduces the flying probe tester, which is a testing device for PCB. The architecture and principle of flying probe tester are firstly introduced. Then the implementation of hardware and software is illuminated briefly. Finally, the optimizing method for the probe's moving path is researched based on the traveling salesman problem.

  4. The Van Allen Probes mission

    CERN Document Server

    Burch, James

    2014-01-01

    This collection of articles provides broad and detailed information about NASA’s Van Allen Probes (formerly known as the Radiation Belt Storm Probes) twin-spacecraft Earth-orbiting mission. The mission has the objective of achieving predictive understanding of the dynamic, intense, energetic, dangerous, and presently unpredictable belts of energetic particles that are magnetically trapped in Earth’s space environment above the atmosphere. It documents the science of the radiation belts and the societal benefits of achieving predictive understanding. Detailed information is provided about the Van Allen Probes mission design, the spacecraft, the science investigations, and the onboard instrumentation that must all work together to make unprecedented measurements within a most unforgiving environment, the core of Earth’s most intense radiation regions.
 This volume is aimed at graduate students and researchers active in space science, solar-terrestrial interactions and studies of the up...

  5. Influence of probe geometry on the response of an electrostatic probe

    DEFF Research Database (Denmark)

    Johansson, Torben; Crichton, George C; McAllister, Iain Wilson

    1999-01-01

    The response of an electrostatic probe is examined with reference to the probe geometry. The study involves the evaluation of the probe lambda function, from which response-related characteristic parameters can be derived. These parameters enable the probe detection sensitivity Se and spatial...

  6. Zero voltage mass spectrometry probes and systems

    Energy Technology Data Exchange (ETDEWEB)

    Cooks, Robert Graham; Wleklinski, Michael Stanley; Bag, Soumabha; Li, Yafeng

    2017-10-10

    The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

  7. Project Prometheus and Future Entry Probe Missions

    Science.gov (United States)

    Spilker, Thomas R.

    2005-01-01

    A viewgraph presentation on project Prometheus and future entry probe missions is shown. The topics include: 1) What Is Project Prometheus?; 2) What Capabilities Can Project Prometheus Offer? What Mission Types Are Being Considered?; 3) Jupiter Icy Moons Orbiter (JIMO); 4) How Are Mission Opportunities Changing?; 5) Missions Of Interest a Year Ago; 6) Missions Now Being Considered For Further Study; 7) Galileo-Style (Conventional) Probe Delivery; 8) Galileo-Style Probe Support; 9) Conventional Delivery and Support of Multiple Probes; 10) How Entry Probe Delivery From an NEP Vehicle Is Different; and 11) Concluding Remarks.

  8. Flexible Ultrasonic Phased-Array Probe

    Institute of Scientific and Technical Information of China (English)

    施克仁; 阙开良; 郭大勇

    2004-01-01

    In ultrasonic phased-array testing, most probes are rigid with fixed elements. However, when testing a cambered piece, a rigid probe cannot be used directly, but an ultrasonic chock or coupling media must be used, which adds cost and reduces the accuracy. The objective of this research was to improve the tests of cambered pieces. A flexible ultrasonic phased-array probe was developed to do the flexible phased-array testing. The key technologies in the flexible phased-array probe include the probe design and the phased-array control. A new method was developed to design the flexible probe according to the curvature of the piece and the test depth. The method includes the calculation of the element's height (he), the relative rotation angle ((e), the distance between the adjoining elements (de), and the element's effective testing range. A flexible ultrasonic phased-array probe has been developed using this method.

  9. Probing the nano-bio interface with nanoplasmonic optical probes

    Science.gov (United States)

    Yu, X.; Wu, Linxi; Khanehzar, Ali; Feizpour, Amin; Xu, Fangda; Reinhard, Björn M.

    2014-08-01

    Noble metal nanoparticles have large cross-sections in both optical and electron microscopy and plasmon coupling between noble metal nanoparticles facilitate the characterization of subdiffraction limit separations through spectral analysis of the scattered light in Plasmon Coupling Microscopy (PCM). The size compatibility of noble metal nanoparticles together with the ability to encode specific functionality in a rational fashion by control of the nanoparticle surface makes noble metal nanoparticles unique probes for a broad range of biological processes. Recent applications of the technology include i.) characterization of cellular heterogeneity in nanomaterial uptake and processing through macrophages, ii.) testing the role of viral membrane lipids in mediating viral binding and trafficking, and iii.) characterizing the spatial organization of cancer biomarkers in plasma membranes. This paper reviews some of these applications and introduces the physical and material science principles underlying them. We will also introduce the use of membrane wrapped noble metal nanoparticles, which combine the superb photophysical properties of a nanoparticle core with the biological functionality of a membrane, as probes in PCM.

  10. Transmit-receive eddy current probes for defect detection and sizing in steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Obrutsky, L.S.; Cecco, V.S.; Sullivan, S.P. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1997-02-01

    Inspection of steam generator tubes in aging Nuclear Generating Stations is increasingly important. Defect detection and sizing, especially in defect prone areas such as the tubesheet, support plates and U-bend regions, are required to assess the fitness-for-service of the steam generators. Information about defect morphology is required to address operational integrity issues, i.e., risk of tube rupture, number of tubes at risk, consequential leakage. A major challenge continues to be the detection and sizing of circumferential cracks. Utilities around the world have experienced this type of tube failure. Conventional in-service inspection, performed with eddy current bobbin probes, is ineffectual in detecting circumferential cracks in tubing. It has been demonstrated in CANDU steam generators, with deformation, magnetite and copper deposits that multi-channel probes with transmit-receive eddy current coils are superior to those using surface impedance coils. Transmit-receive probes have strong directional properties, permitting probe optimization according to crack orientation. They are less sensitive to lift-off noise and magnetite deposits and possess good discrimination to internal defects. A single pass C3 array transmit-receive probe developed by AECL can detect and size circumferential stress corrosion cracks as shallow as 40% through-wall. Since its first trial in 1992, it has been used routinely for steam generator in-service inspection of four CANDU plants, preventing unscheduled shutdowns due to leaking steam generator tubes. More recently, a need has surfaced for simultaneous detection of both circumferential and axial cracks. The C5 probe was designed to address this concern. It combines transmit-receive array probe technology for equal sensitivity to axial and circumferential cracks with a bobbin probe for historical reference. This paper will discuss the operating principles of transmit-receive probes, along with inspection results.

  11. Astrophysical probes of fundamental physics

    Energy Technology Data Exchange (ETDEWEB)

    Martins, C.J.A.P. [Centro de Astrofisica, Universidade do Porto, Rua das Estrelas, 4150-762 Porto (Portugal); DAMTP, University of Cambridge, Wilberforce Road, Cambridge CB3 0WA (United Kingdom)

    2009-10-15

    I review the motivation for varying fundamental couplings and discuss how these measurements can be used to constrain fundamental physics scenarios that would otherwise be inaccessible to experiment. I highlight the current controversial evidence for varying couplings and present some new results. Finally I focus on the relation between varying couplings and dark energy, and explain how varying coupling measurements might be used to probe the nature of dark energy, with some advantages over standard methods. In particular I discuss what can be achieved with future spectrographs such as ESPRESSO and CODEX.

  12. Soft QGP probes with ALICE

    CERN Document Server

    Graczykowski, Łukasz Kamil

    2016-01-01

    In heavy-ion collisions at the LHC a hot and dense medium of deconfided partons, the Quark-Gluon Plasma (QGP), is created. Its global properties can be characterized by the measurements of particles in the low transverse momentum (or "soft") regime, which represent the majority of created particles. In this report we outline a selection of measurements of the soft probes by the ALICE experiment in pp, p--Pb, and Pb--Pb collisions. The paper focuses on recent flow measurements via angular correlations and femtoscopic studies. The first ever preliminary analysis of $\\mathrm{K}^0_{\\rm S}\\mathrm{K}^{\\pm}$ femtoscopy is also presented.

  13. Radiation damping in microcoil NMR probes.

    Science.gov (United States)

    Krishnan, V V

    2006-04-01

    Radiation damping arises from the field induced in the receiver coil by large bulk magnetization and tends to selectively drive this magnetization back to equilibrium much faster than relaxation processes. The demand for increased sensitivity in mass-limited samples has led to the development of microcoil NMR probes that are capable of obtaining high quality NMR spectra with small sample volumes (nL-microL). Microcoil probes are optimized to increase sensitivity by increasing either the sample-to-coil ratio (filling factor) of the probe or quality factor of the detection coil. Though radiation damping effects have been studied in standard NMR probes, these effects have not been measured in the microcoil probes. Here a systematic evaluation of radiation damping effects in a microcoil NMR probe is presented and the results are compared with similar measurements in conventional large volume samples. These results show that radiation-damping effects in microcoil probe is much more pronounced than in 5 mm probes, and that it is critically important to optimize NMR experiments to minimize these effects. As microcoil probes provide better control of the bulk magnetization, with good RF and B0 inhomogeneity, in addition to negligible dipolar field effects due to nearly spherical sample volumes, these probes can be used exclusively to study the complex behavior of radiation damping.

  14. ProbeMaker: an extensible framework for design of sets of oligonucleotide probes

    Science.gov (United States)

    Stenberg, Johan; Nilsson, Mats; Landegren, Ulf

    2005-01-01

    Background Procedures for genetic analyses based on oligonucleotide probes are powerful tools that can allow highly parallel investigations of genetic material. Such procedures require the design of large sets of probes using application-specific design constraints. Results ProbeMaker is a software framework for computer-assisted design and analysis of sets of oligonucleotide probe sequences. The tool assists in the design of probes for sets of target sequences, incorporating sequence motifs for purposes such as amplification, visualization, or identification. An extension system allows the framework to be equipped with application-specific components for evaluation of probe sequences, and provides the possibility to include support for importing sequence data from a variety of file formats. Conclusion ProbeMaker is a suitable tool for many different oligonucleotide design and analysis tasks, including the design of probe sets for various types of parallel genetic analyses, experimental validation of design parameters, and in silico testing of probe sequence evaluation algorithms. PMID:16171527

  15. Advanced oxidation scanning probe lithography

    Science.gov (United States)

    Ryu, Yu K.; Garcia, Ricardo

    2017-04-01

    Force microscopy enables a variety of approaches to manipulate and/or modify surfaces. Few of those methods have evolved into advanced probe-based lithographies. Oxidation scanning probe lithography (o-SPL) is the only lithography that enables the direct and resist-less nanoscale patterning of a large variety of materials, from metals to semiconductors; from self-assembled monolayers to biomolecules. Oxidation SPL has also been applied to develop sophisticated electronic and nanomechanical devices such as quantum dots, quantum point contacts, nanowire transistors or mechanical resonators. Here, we review the principles, instrumentation aspects and some device applications of o-SPL. Our focus is to provide a balanced view of the method that introduces the key steps in its evolution, provides some detailed explanations on its fundamentals and presents current trends and applications. To illustrate the capabilities and potential of o-SPL as an alternative lithography we have favored the most recent and updated contributions in nanopatterning and device fabrication.

  16. Compact Nanowire Sensors Probe Microdroplets.

    Science.gov (United States)

    Schütt, Julian; Ibarlucea, Bergoi; Illing, Rico; Zörgiebel, Felix; Pregl, Sebastian; Nozaki, Daijiro; Weber, Walter M; Mikolajick, Thomas; Baraban, Larysa; Cuniberti, Gianaurelio

    2016-08-10

    The conjunction of miniature nanosensors and droplet-based microfluidic systems conceptually opens a new route toward sensitive, optics-less analysis of biochemical processes with high throughput, where a single device can be employed for probing of thousands of independent reactors. Here we combine droplet microfluidics with the compact silicon nanowire based field effect transistor (SiNW FET) for in-flow electrical detection of aqueous droplets one by one. We chemically probe the content of numerous (∼10(4)) droplets as independent events and resolve the pH values and ionic strengths of the encapsulated solution, resulting in a change of the source-drain current ISD through the nanowires. Further, we discuss the specificities of emulsion sensing using ion sensitive FETs and study the effect of droplet sizes with respect to the sensor area, as well as its role on the ability to sense the interior of the aqueous reservoir. Finally, we demonstrate the capability of the novel droplets based nanowire platform for bioassay applications and carry out a glucose oxidase (GOx) enzymatic test for glucose detection, providing also the reference readout with an integrated parallel optical detector.

  17. Tunable nanowire nonlinear optical probe

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yuri; Pauzauskie, Peter J.; Radenovic, Aleksandra; Onorato, Robert M.; Saykally, Richard J.; Liphardt, Jan; Yang, Peidong

    2008-02-18

    One crucial challenge for subwavelength optics has been thedevelopment of a tunable source of coherent laser radiation for use inthe physical, information, and biological sciences that is stable at roomtemperature and physiological conditions. Current advanced near-fieldimaging techniques using fiber-optic scattering probes1,2 have alreadyachieved spatial resolution down to the 20-nm range. Recently reportedfar-field approaches for optical microscopy, including stimulatedemission depletion (STED)3, structured illumination4, and photoactivatedlocalization microscopy (PALM)5, have also enabled impressive,theoretically-unlimited spatial resolution of fluorescent biomolecularcomplexes. Previous work with laser tweezers6-8 has suggested the promiseof using optical traps to create novel spatial probes and sensors.Inorganic nanowires have diameters substantially below the wavelength ofvisible light and have unique electronic and optical properties9,10 thatmake them prime candidates for subwavelength laser and imagingtechnology. Here we report the development of an electrode-free,continuously-tunable coherent visible light source compatible withphysiological environments, from individual potassium niobate (KNbO3)nanowires. These wires exhibit efficient second harmonic generation(SHG), and act as frequency converters, allowing the local synthesis of awide range of colors via sum and difference frequency generation (SFG,DFG). We use this tunable nanometric light source to implement a novelform of subwavelength microscopy, in which an infrared (IR) laser is usedto optically trap and scan a nanowire over a sample, suggesting a widerange of potential applications in physics, chemistry, materials science,and biology.

  18. Sensitive Probe for Symmetry Potential

    Institute of Scientific and Technical Information of China (English)

    LIU Jian-Ye; XIAO Guo-Qing; GUO Wen-Jun; REN ZhongZhou; ZUO Wei; LEE Xi-Guo

    2007-01-01

    Based on both very obvious isospin effect of the neutron-proton number ratio of nucleon emissions (n/p)nucl on symmetry potential and (n/p)nucl's sensitive dependence on symmetry potential in the nuclear reactions induced by halo-neutron projectiles, compared to the same mass stable projectile, probing symmetry potential is investigated within the isospin-dependent quantum molecular dynamics with isospin and momentum-dependent interactions for different symmetry potentials U1sym and U2sym. It is found that the neutron-halo projectile induces very obvious increase of (n/p)nucl and strengthens the dependence of (n/p)nucl on the symmetry potential for all the beam energies and impact parameters, compared to the same mass stable projectile under the same incident channel condition. Therefore (n/p)nucl induced by the neutron-halo projectile is a more favourable probe than the normal neutron-rich and neutron-poor projectiles for extracting the symmetry potential.

  19. Information Gains from Cosmological Probes

    CERN Document Server

    Grandis, S; Refregier, A; Amara, A; Nicola, A

    2015-01-01

    In light of the growing number of cosmological observations, it is important to develop versatile tools to quantify the constraining power and consistency of cosmological probes. Originally motivated from information theory, we use the relative entropy to compute the information gained by Bayesian updates in units of bits. This measure quantifies both the improvement in precision and the 'surprise', i.e. the tension arising from shifts in central values. Our starting point is a WMAP9 prior which we update with observations of the distance ladder, supernovae (SNe), baryon acoustic oscillations (BAO), and weak lensing as well as the 2015 Planck release. We consider the parameters of the flat $\\Lambda$CDM concordance model and some of its extensions which include curvature and Dark Energy equation of state parameter $w$. We find that, relative to WMAP9 and within these model spaces, the probes that have provided the greatest gains are Planck (10 bits), followed by BAO surveys (5.1 bits) and SNe experiments (3.1 ...

  20. Advanced oxidation scanning probe lithography.

    Science.gov (United States)

    Ryu, Yu K; Garcia, Ricardo

    2017-04-07

    Force microscopy enables a variety of approaches to manipulate and/or modify surfaces. Few of those methods have evolved into advanced probe-based lithographies. Oxidation scanning probe lithography (o-SPL) is the only lithography that enables the direct and resist-less nanoscale patterning of a large variety of materials, from metals to semiconductors; from self-assembled monolayers to biomolecules. Oxidation SPL has also been applied to develop sophisticated electronic and nanomechanical devices such as quantum dots, quantum point contacts, nanowire transistors or mechanical resonators. Here, we review the principles, instrumentation aspects and some device applications of o-SPL. Our focus is to provide a balanced view of the method that introduces the key steps in its evolution, provides some detailed explanations on its fundamentals and presents current trends and applications. To illustrate the capabilities and potential of o-SPL as an alternative lithography we have favored the most recent and updated contributions in nanopatterning and device fabrication.

  1. An improved hand-held four-detector gamma-probe for radioassisted oncological surgery

    CERN Document Server

    Dusi, W; Bollini, D; Moroni, C; Ricard, M

    2000-01-01

    The performance of an improved intraoperative gamma-probe for radioassisted oncological surgery is presented and discussed. The probe is based on a square array of four 5x5 mm sup 2 coplanar CdTe room temperature semiconductor detectors and each detector has an independent read out electronic chain, allowing an original handling of the signal. Therefore, the search for gamma-emission hot points may be carried out in two different, independent ways: (1) Finding out the position of the probe corresponding to the maximum value of the total counting rate, on the basis of a trial and error procedure (typical for the conventional probe; (2) Finding out the position of the probe where both the differences between the counting rate performed by orthogonal, adjacent halves of the array vanish (differential method). This makes the new probe sensitive to the bidimensional gradient of the gamma-ray flux, measured on the scanned plane. Furthermore, the algebraic sign of the difference indicates in which direction the prob...

  2. Informed Consent (Clinical Trials)

    Science.gov (United States)

    ... Research Cancer Treatment Types of Treatment Side Effects Clinical Trials Information A to Z List of Cancer Drugs ... Staging Prognosis Treatment Types of Treatment Side Effects Clinical Trials Cancer Drugs Complementary & Alternative Medicine Coping Feelings & Cancer ...

  3. Research Areas - Clinical Trials

    Science.gov (United States)

    Information about NCI programs and initiatives that sponsor, conduct, develop, or support clinical trials, including NCI’s Clinical Trial Network (NCTN) and NCI Community Oncology Research Program (NCORP) initiatives.

  4. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... Institutes of Health funds much of this basic research. Screening Trials In screening trials, researchers study ways of finding a disease before symptoms occur. These methods, often called screening tests, can include imaging tests ...

  5. ClinicalTrials.gov

    Science.gov (United States)

    ... to This Site Terms and Conditions Disclaimer ClinicalTrials.gov is a registry and results database of publicly ... of human participants conducted around the world. ClinicalTrials.gov is a registry and results database of publicly ...

  6. Creating and Probing Graphene Electron Optics with Local Scanning Probes

    Science.gov (United States)

    Stroscio, Joseph

    Ballistic propagation and the light-like dispersion of graphene charge carriers make graphene an attractive platform for optics-inspired graphene electronics where gate tunable potentials can control electron refraction and transmission. In analogy to optical wave propagation in lenses, mirrors and metamaterials, gate potentials can be used to create a negative index of refraction for Veselago lensing and Fabry-Pérot interferometers. In circular geometries, gate potentials can induce whispering gallery modes (WGM), similar to optical and acoustic whispering galleries albeit on a much smaller length scale. Klein scattering of Dirac carriers plays a central role in determining the coherent propagation of electron waves in these resonators. In this talk, I examine the probing of electron resonators in graphene confined by linear and circular gate potentials with the scanning tunneling microscope (STM). The tip in the STM tunnel junction serves both as a tunable local gate potential, and as a probe of the graphene states through tunneling spectroscopy. A combination of a back gate potential, Vg, and tip potential, Vb, creates and controls a circular pn junction that confines the WGM graphene states. The resonances are observed in two separate channels in the tunneling spectroscopy experiment: first, by directly tunneling into the state at the bias energy eVb, and, second, by tunneling from the resonance at the Fermi level as the state is gated by the tip potential. The second channel produces a fan-like set of WGM peaks, reminiscent of the fringes seen in planar geometries by transport measurements. The WGM resonances split in a small applied magnetic field, with a large energy splitting approaching the WGM spacing at 0.5 T. These results agree well with recent theory on Klein scattering in graphene electron resonators. This work is done in collaboration with Y. Zhao, J. Wyrick, F.D. Natterer, J. F. Rodriquez-Nieva, C. Lewandoswski, K. Watanabe, T. Taniguchi, N. B

  7. Aspects of probe correction for odd-order probes in spherical near-field antenna measurements

    DEFF Research Database (Denmark)

    Laitinen, Tommi; Pivnenko, Sergey N.; Breinbjerg, Olav

    2004-01-01

    Probe correction aspects for the spherical near-field antenna measurements are investigated. First, the spherical mode analyses of the radiated fields of several antennas are performed. It is shown that many common antennas are essentially so-called odd-order antennas. Second, the errors caused...... by the use of the first-order probe correction [1] for a rectangular waveguide probe, that is an odd-order antenna, are demonstrated. Third, a recently developed probe correction technique for odd-order probes is applied for the rectangular waveguide probe and shown to provide accurate results....

  8. Visual-Inspection Probe For Cryogenic Chamber

    Science.gov (United States)

    Friend, Steve; Valenzuela, James; Yoshinaga, Jay

    1990-01-01

    Visual-inspection probe that resembles borescope enables observer at ambient temperature to view objects immersed in turbulent flow of liquid oxygen, liquid nitrogen, or other cryogenic fluid. Design of probe fairly conventional, except special consideration given to selection of materials and to thermal expansion to provide for expected range of operating temperatures. Penetrates wall of cryogenic chamber to provide view of interior. Similar probe illuminates scene. View displayed on video monitor.

  9. Characterization of Akiyama probe applied to dual-probes atomic force microscope

    Science.gov (United States)

    Wang, Hequn; Gao, Sitian; Li, Wei; Shi, Yushu; Li, Qi; Li, Shi; Zhu, Zhendong

    2016-10-01

    The measurement of nano-scale line-width has always been important and difficult in the field of nanometer measurements, while the rapid development of integrated circuit greatly raises the demand again. As one kind of scanning probe microscope (SPM), atomic force microscope (AFM) can realize quasi three-dimensional measurement, which is widely used in nanometer scale line-width measurement. Our team researched a dual-probes atomic force microscope, which can eliminate the prevalent effect of probe width on measurement results. In dual-probes AFM system, a novel head are newly designed. A kind of self-sensing and self-exciting probes which is Nanosensors cooperation's patented probe—Akiyama probe, is used in this novel head. The Akiyama probe applied to dual-probe atomic force microscope is one of the most important issues. The characterization of Akiyama probe would affect performance and accuracy of the whole system. The fundamental features of the Akiyama probe are electrically and optically characterized in "approach-withdraw" experiments. Further investigations include the frequency response of an Akiyama probe to small mechanical vibrations externally applied to the tip and the effective loading force yielding between the tip and the sample during the periodic contact. We hope that the characterization of the Akiyama probe described in this paper will guide application for dual-probe atomic force microscope.

  10. Scanning microscopic four-point conductivity probes

    DEFF Research Database (Denmark)

    Petersen, Christian Leth; Hansen, Torben Mikael; Bøggild, Peter

    2002-01-01

    A method for fabricating microscopic four-point probes is presented. The method uses silicon-based microfabrication technology involving only two patterning steps. The last step in the fabrication process is an unmasked deposition of the conducting probe material, and it is thus possible to select...... the conducting material either for a silicon wafer or a single probe unit. Using shadow masking photolithography an electrode spacing (pitch) down to 1.1 mum was obtained, with cantilever separation down to 200 run. Characterisation measurements have shown the microscopic probes to be mechanically very flexible...

  11. Probing the String Winding Sector

    CERN Document Server

    Aldazabal, Gerardo; Nuñez, Carmen

    2016-01-01

    We probe a slice of the massive winding sector of bosonic string theory from toroidal compactifications of Double Field Theory (DFT). This string subsector corresponds to states containing one left and one right moving oscillators. We perform a generalized Kaluza Klein compactification of DFT on generic $2n$-dimensional toroidal constant backgrounds and show that, up to third order in fluctuations, the theory coincides with the corresponding effective theory of the bosonic string compactified on $n$-dimensional toroidal constant backgrounds, obtained from three-point amplitudes. The comparison between both theories is facilitated by noticing that generalized diffeomorphisms in DFT allow to fix generalized harmonic gauge conditions that help in identifying the physical degrees of freedom. These conditions manifest as conformal anomaly cancellation requirements on the string theory side. The explicit expression for the gauge invariant effective action containing the physical massless sector (gravity+antisymmetr...

  12. Scanning probe microscopy competency development

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, M.E.; Reagor, D.W.; Jia, Quan Xi [and others

    1998-12-31

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The project collaborators developed an ultra-high vacuum scanning tunneling microscope (UHV-STM) capability, integrated it with existing scanning probe microscopes, and developed new, advanced air-based scanning force techniques (SPMs). Programmatic, basic, and industrially related laboratory research requires the existence of SPMs, as well as expertise capable of providing local nano-scale information. The UHV-STM capability, equipped with load-lock system and several surface science techniques, will allow introduction, examination, and reaction of surfaces prepared under well-controlled vacuum conditions, including the examination of morphology and local bonding associated with the initial stages of film growth under controlled growth conditions. The resulting capabilities will enable the authors to respond to a variety of problems requiring local characterization of conducting and nonconducting surfaces in liquids, air, and UHV.

  13. Astrophysical Probes of Fundamental Physics

    CERN Document Server

    Martins, C J A P

    2006-01-01

    I review the theoretical motivation for varying fundamental couplings and discuss how these measurements can be used to constrain a number of fundamental physics scenarios that would otherwise be inacessible to experiment. As a case study I will focus on the relation between varying couplings and dark energy, and explain how varying coupling measurements can be used to probe the nature of dark energy, with important advantages over the standard methods. Assuming that the current observational evidence for varying $\\alpha$ and $\\mu$ is correct, a several-sigma detection of dynamical dark energy is feasible within a few years, using currently operational ground-based facilities. With forthcoming instruments like CODEX, a high-accuracy reconstruction of the equation of state may be possible all the way up to redshift $z\\sim4$.

  14. New Fluorescence Probes for Biomolecules

    Directory of Open Access Journals (Sweden)

    Katarzyna Jurek

    2015-07-01

    Full Text Available Steady state fluorescence measurements have been used for the investigation of interaction between the bovine serum albumin (BSA and fluorescence probes: 3-hydroxy-2,4- bis[(3-methyl-1,3-benzoxazol-2(3H-ylidenemethyl]cyclobut-2-en-1-one (SQ6, 3-hydroxy- 2,4-bis[(3-methyl-1,3-benzothiazol-2(3H-ylidenemethyl]cyclobut-2-en-1-one (SQ7 and 3-hydroxy-2,4-bis[(1,3,3-trimethyl-1,3-dihydro-2H-indol-2-ylidenemethyl]cyclobut-2-en-1-one (SQ8. The binding constant between bovine serum albumin and squarine dyes has been determined by using both the Benesi-Hildebrand and Stern-Volmer equations. The negative value of free energy change indicates the existence of a spontaneous complexation process of BSA with squarine dyes.

  15. Angular distributions as lifetime probes

    Energy Technology Data Exchange (ETDEWEB)

    Dror, Jeff Asaf; Grossman, Yuval [Department of Physics, LEPP, Cornell University,Ithaca, NY 14853 (United States)

    2014-06-27

    If new TeV scale particles are discovered, it will be important to determine their width. There is, however, a problematic region, where the width is too small to be determined directly, and too large to generate a secondary vertex. For a collection of colored, spin polarized particles, hadronization depolarizes the particles prior to their decay. The amount of depolarization can be used to probe the lifetime in the problematic region. In this paper we apply this method to a realistic scenario of a top-like particle that can be produced at the LHC. We study how depolarization affects the angular distributions of the decay products and derive an equation for the distributions that is sensitive to the lifetime.

  16. Angular Distributions as Lifetime Probes

    CERN Document Server

    Dror, Jeff Asaf

    2013-01-01

    If new TeV scale particles are discovered, it will be important to determine their width. There is, however, a problematic region, where the width is too small to be determined directly, and too large to generate a secondary vertex. For a collection of colored, spin polarized particles, hadronization depolarizes the particles prior to their decay. The amount of depolarization can be used to probe the lifetime in the problematic region. In this paper we apply this method to a realistic scenario of a top-like particle that can be produced at the LHC. We study how depolarization affects the angular distributions of the decay products and derive an equation for the distributions that is sensitive to the lifetime.

  17. Understanding noninferiority trials

    Directory of Open Access Journals (Sweden)

    Seokyung Hahn

    2012-11-01

    Full Text Available Noninferiority trials test whether a new experimental treatment is not unacceptably less efficacious than an active control treatment already in use. With continuous improvements in health technologies, standard care, and clinical outcomes, the incremental benefits of newly developed treatments may be only marginal over existing treatments. Sometimes assigning patients to a placebo is unethical. In such circumstances, there has been increasing emphasis on the use of noninferiority trial designs. Noninferiority trials are more complex to design, conduct, and interpret than typical superiority trials. This paper reviews the concept of noninferiority trials and discusses some important issues related to them.

  18. Coke state determination in the blast furnace hearth using a tuyere probe

    Energy Technology Data Exchange (ETDEWEB)

    Negro, P.; Pierret, H.; Steiler, J.M. (Institut de Recherches de la Siderurgie Francaise (IRSID), 78 - Saint-Germain-en-Laye (France)); Lao, D.; Eymond, J.L.; Fauchoit, P. (Sollac, 59 - Dunkerque (France)); Eibes, C.; Blaise, G.; Urvoy, A.; Helleisen, M.; Giroldini, F.; Hartig, M.; Rausch, H.

    1993-04-01

    Coke samplings at blast furnace tuyeres are a powerful mean to study the behaviour of the lower part of the furnace. A tuyere probe has been installed since April 1985 on the BF 2 at Sollac Fos. This probe is 19 m long and 11 tons weight. It uses a 265 mm internal diameter pipe which samples materials until the centre of the BF. Up-to-now, 28 trials have been completed. The results obtained with this probe allow: a better understanding of the phenomena occurring in the blast furnace hearth, to establish several relationships between the internal state of the hearth and the operation conditions, to build and validate a new image of the cohesive zone and the coke state, to measure and understand the influence of coal injection on the BF operation. Since April 1991, a movable tuyere probe has been in operation within Usinor Sacilor Group. This machine is more lighter than the fixed one weighing only 5.5 tons and smaller measuring 5 m long for 1.3 m width. The probe is a 260 mm internal diameter pipe which can be introduced for 4.25 m in the furnace. In 20 months, it is more than 40 coke core borings which have been achieved on 9 different furnaces of 4 different plants. These two probes are complementary. The fixed probe is only used through one tuyere of one BF. In addition, this probe can reach the centre of the furnace and give a complete description of the materials present along the radius. The movable machine cannot reach the centre of the BF, but it authorizes the study of: some very different BF operating conditions, the influence of the feed materials qualities in a large range, the heterogeneity between several tuyeres of one BF, the effect of the BF size. This text presents our approach in coke quality research, relying upon the results of coke core borings. 6 refs., 17 figs.

  19. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    Science.gov (United States)

    Hall, B. F.; Povey, T.

    2017-03-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design.

  20. Advances of molecular imaging probes for the diagnosis of Alzheimer's disease.

    Science.gov (United States)

    Zhou, Ming; Wang, Xiaobo; Liu, Zhiguo; Yu, Lun; Hu, Shuo; Chen, Lizhang; Zeng, Wenbin

    2014-03-01

    Alzheimer's disease (AD) is a neurodegenerative disorder characterized by progressive decline in multiple cognitive domains and it becomes the most common cause of dementia in the elderly. There is an urgent need for the early diagnosis and treatment of AD to ease caregiver burden and medical costs, as well as improve patients' living activities associated with the dramatic increasing number of affected individuals. Molecular imaging with target-specific probes is contributing to identify the underlying biology in AD, which benefits to the early diagnosis of AD and the evaluation of anti-AD therapy. Molecular imaging probes, such as (11)C-PIB, (11)C-MP4A, (18)F-AV-45, and (11)F-FDG, can selectively bind to special bimolecular of AD or accurately accumulate at the location of damage areas, thus become an edge tool for a better management of the diseases in the clinical practice and new drug development. In the past decades, a large variety of probes is being developed and tested to be useful for the early and accurate diagnosis of Alzheimer's disease, patient selection for disease-modifying therapeutic trials and monitoring the effect of anti-amyloid therapy. Since imaging probes may also help to guide physicians to identify those patients that could best benefit from a given therapeutic regimen, dose, or duration of drug, this paper is to present a perspective of the available imaging probes for AD, classified on different modalities. Meanwhile, recent advances of those probes that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval are outlined. Additionally, future directions and specific application of imaging strategies designed for both diagnosis and treatment for AD are discussed.

  1. Development of a transient internal probe diagnostic

    Science.gov (United States)

    Spanjers, G. G.; Galambos, J. P.; Bohnet, M. A.; Jarboe, T. R.; Christiansen, W. H.; Wurden, G. A.; Wright, B. L.; Smith, R. J.

    1992-10-01

    The transient internal probe (TIP) diagnostic is a novel method for probing the interior of hot magnetic fusion plasmas. In the TIP scheme, a probe is fired, using a two-stage light gas gun, through a hot plasma at velocities up to 5 km/s, and makes direct, local measurements of the internal magnetic field structure. The data are relayed to the laboratory optical detection system using an incident laser that is directed through a Faraday rotator payload acting as a magneto-optic sensor. Ablative effects are avoided by minimizing the probe size, limiting the time that the probe is in the hot plasma, and encasing the probe with a diamond cladding. The degree to which the diamond probe cladding is susceptible to ablative effects will determine the plasma density and temperature regime in which the TIP diagnostic can be used. If the TIP suffers significant ablation it is an indication that the diagnostic is not usable on this hot and dense of a plasma (or that greater velocity must be imparted to the probe to further minimize the time that it is in the plasma). A quantitative experimental study of the ablation rates of diamond is planned as part of the TIP development. The integrated TIP system will be functional in 1992 and installed on the Helicity Injected Torus (HIT) [T. R. Jarboe, Fusion Tech. 15, 9 (1989)] at the University of Washington.

  2. Planar microcoil-based microfluidic NMR probes.

    NARCIS (Netherlands)

    Massin, C.; Vincent, F.; Homsy, A.; Ehrmann, K.; Boero, G.; Besse, P-A; Daridon, A.; Verpoorte, E.; de Rooij, N.F.; Popovic, R.S.

    2003-01-01

    Microfabricated small-volume NMR probes consisting of electroplated planar microcoils integrated on a glass substrate with etched microfluidic channels are fabricated and tested. 1H NMR spectra are acquired at 300 MHz with three different probes having observed sample volumes of respectively 30, 120

  3. Fluorescent hybridization probes for nucleic acid detection.

    Science.gov (United States)

    Guo, Jia; Ju, Jingyue; Turro, Nicholas J

    2012-04-01

    Due to their high sensitivity and selectivity, minimum interference with living biological systems, and ease of design and synthesis, fluorescent hybridization probes have been widely used to detect nucleic acids both in vivo and in vitro. Molecular beacons (MBs) and binary probes (BPs) are two very important hybridization probes that are designed based on well-established photophysical principles. These probes have shown particular applicability in a variety of studies, such as mRNA tracking, single nucleotide polymorphism (SNP) detection, polymerase chain reaction (PCR) monitoring, and microorganism identification. Molecular beacons are hairpin oligonucleotide probes that present distinctive fluorescent signatures in the presence and absence of their target. Binary probes consist of two fluorescently labeled oligonucleotide strands that can hybridize to adjacent regions of their target and generate distinctive fluorescence signals. These probes have been extensively studied and modified for different applications by modulating their structures or using various combinations of fluorophores, excimer-forming molecules, and metal complexes. This review describes the applicability and advantages of various hybridization probes that utilize novel and creative design to enhance their target detection sensitivity and specificity.

  4. Planar microcoil-based microfluidic NMR probes.

    NARCIS (Netherlands)

    Massin, C.; Vincent, F.; Homsy, A.; Ehrmann, K.; Boero, G.; Besse, P-A; Daridon, A.; Verpoorte, E.; de Rooij, N.F.; Popovic, R.S.

    2003-01-01

    Microfabricated small-volume NMR probes consisting of electroplated planar microcoils integrated on a glass substrate with etched microfluidic channels are fabricated and tested. 1H NMR spectra are acquired at 300 MHz with three different probes having observed sample volumes of respectively 30, 120

  5. Inspecting Friction Stir Welding using Electromagnetic Probes

    Science.gov (United States)

    Kinchen, David G.

    2004-01-01

    A report describes the use of advanced electromagnetic probes to measure the dimensions, the spatial distribution of electrical conductivity, and related other properties of friction stir welds (FSWs) between parts made of the same or different aluminum alloy(s). The probes are of the type described in in another Tech Brief. To recapitulate: A probe of this type is essentially an eddy-current probe that includes a primary (driver) winding that meanders and multiple secondary (sensing) windings that meander along the primary winding. Electrical conductivity is commonly used as a measure of heat treatment and tempering of aluminum alloys, but prior to the development of these probes, the inadequate sensitivity and limited accuracy of electrical-conductivity probes precluded such use on FSWs between different aluminum alloys, and the resolution of those probes was inadequate for measurement of FSW dimensions with positions and metallurgical properties. In contrast, the present probes afford adequate accuracy and spatial resolution for the purposes of measuring the dimensions of FSW welds and correlating spatially varying electrical conductivities with metallurgical properties, including surface defects.

  6. Miniature standoff Raman probe for neurosurgical applications

    Science.gov (United States)

    Stevens, Oliver A. C.; Hutchings, Joanne; Gray, William; Vincent, Rosa Louise; Day, John C.

    2016-08-01

    Removal of intrinsic brain tumors is a delicate process, where a high degree of specificity is required to remove all of the tumor tissue without damaging healthy brain. The accuracy of this process can be greatly enhanced by intraoperative guidance. Optical biopsies using Raman spectroscopy are a minimally invasive and lower-cost alternative to current guidance methods. A miniature Raman probe for performing optical biopsies of human brain tissue is presented. The probe allows sampling inside a conventional stereotactic brain biopsy system: a needle of length 200 mm and inner diameter of 1.8 mm. By employing a miniature stand-off Raman design, the probe removes the need for any additional components to be inserted into the brain. Additionally, the probe achieves a very low internal silica background while maintaining good collection of Raman signal. To illustrate this, the probe is compared with a Raman probe that uses a pair of optical fibers for collection. The miniature stand-off Raman probe is shown to collect a comparable number of Raman scattered photons, but the Raman signal to background ratio is improved by a factor of five at Raman shifts below ˜500 cm-1. The probe's suitability for use on tissue is demonstrated by discriminating between different types of healthy porcine brain tissue.

  7. Surface charge measurement using an electrostatic probe

    DEFF Research Database (Denmark)

    Crichton, George C; McAllister, Iain Wilson

    1998-01-01

    During the 1960s, the first measurements of charge on dielectric surfaces using simple electrostatic probes were reported. However it is only within the last 10 years that a proper understanding of the probe response has been developed. This situation arose as a consequence of the earlier studies...

  8. NASA SMART Probe: Breast Cancer Application

    Science.gov (United States)

    Mah, Robert W.; Norvig, Peter (Technical Monitor)

    2000-01-01

    There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

  9. Lessons learned from planetary entry probe missions

    Science.gov (United States)

    Niemann, Hasso; Atreya, Sushil K.; Kasprzak, Wayne

    Probing the atmospheres and surfaces of the planets and their moons with fast moving entry probes has been a very useful and essential technique to obtain in situ or quasi in situ scientific data (ground truth) which could not otherwise be obtained from fly by or orbiter only missions and where balloon, aircraft or lander missions are too complex and too costly. Planetary entry probe missions have been conducted successfully on Venus, Mars, Jupiter and Titan after having been first demonstrated in the Earth's atmosphere. Future planetary missions should also include more entry probe missions back to Venus and to the outer planets. The success of and science returns from past missions, the need for more and unique data, and a continuously advancing technology generate confidence that future missions will be even more successful with respect to science return and technical performance. There are, however, unique challenges associated with entry probe missions and with building instruments for an entry probe, as compared to orbiters, landers, or rovers. Conditions during atmospheric entry are extreme. There are operating time constraints due to the usually short duration of the probe descent, and the instruments experience rapid environmental changes in temperature and pressure. In addition, there are resource limitations, i.e. mass, power, size and bandwidth. Because of the protective heat shield and the high acceleration the probe experiences during entry, the ratio of payload to total probe mass is usually much smaller than in other missions. Finally, the demands on the instrument design are determined in large part by conditions (pressure, temperature, composition) unique to the particular body under study, and as a result, there is no one-size-fits-all instrument for an atmospheric probe. Many of these requirements are more easily met by miniaturizing the probe instrumentation and consequently reducing the required size of the probe. Improved heat shield

  10. Theory of dual probes on graphene structures

    DEFF Research Database (Denmark)

    Settnes, Mikkel

    around the local probes. This necessitates a reformulation of the conventional calculation methods allowing for the description of non-periodic structures embedded within infinite samples. The two-dimensional material graphene, is a highly interesting system for multi- probe characterization as graphene......This thesis concerns the development of theoretical and computational methods for multiprobe systems and their application to nanostructured graphene. Recent experimental advances emphasize the usefulness of multi-probe techniques when analyzing the electrical properties of nanoscale samples...... is purely surface and exhibits a wide range of highly intriguing electronic properties. Using a dual probe setup, we demonstrate the application of the developed formalism to a number of different graphene-based systems. The conductance between the two probes in either scanning or spectroscopy mode, shows...

  11. Custom-made Microdialysis Probe Design.

    Science.gov (United States)

    Lietsche, Jana; Gorka, Jan; Hardt, Stefanie; Karas, Michael; Klein, Jochen

    2015-07-21

    Microdialysis is a commonly used technique in neuroscience research. Therefore commercial probes are in great demand to monitor physiological, pharmacological and pathological changes in cerebrospinal fluid. Unfortunately, commercial probes are expensive for research groups in public institutions. In this work, a probe assembly is explained in detail to build a reliable, concentric, custom-made microdialysis probe for less than $10. The microdialysis probe consists of a polysulfone membrane with a molecular cut-off of 30 kDa. Probe in vitro recoveries of substances with different molecular weight (in the range of 100-1,600 Da) and different physicochemical properties are compared. The probe yields an in vitro recovery of approximately 20% for the small compounds glucose, lactate, acetylcholine and ATP. In vitro recoveries for neuropeptides with a molecular weight between 1,000-1,600 Da amount to 2-6%. Thus, while the higher molecular weight of the neuropeptides lowered in vitro recovery values, dialysis of compounds in the lower range (up to 500 Da) of molecular weights has no great impact on the in vitro recovery rate. The present method allows utilization of a dialysis membrane with other cut-off value and membrane material. Therefore, this custom-made probe assembly has the advantage of sufficient flexibility to dialyze substances in a broad molecular weight range. Here, we introduce a microdialysis probe with an exchange length of 2 mm, which is applicable for microdialysis in mouse and rat brain regions. However, dimensions of the probe can easily be adapted for larger exchange lengths to be used in larger animals.

  12. Probe for testing electrical properties of a test sample

    DEFF Research Database (Denmark)

    2012-01-01

    A probe for testing electrical properties of test samples includes a body having a probe arm defining proximal and distal ends, the probe arm extending from the body at the proximal end of the probe arm, whereby a first axis is defined by the proximal and the distal ends. The probe arm defines...

  13. Probing the string winding sector

    Science.gov (United States)

    Aldazabal, Gerardo; Mayo, Martín; Nuñez, Carmen

    2017-03-01

    We probe a slice of the massive winding sector of bosonic string theory from toroidal compactifications of Double Field Theory (DFT). This string subsector corresponds to states containing one left and one right moving oscillators. We perform a generalized Kaluza Klein compactification of DFT on generic 2 n-dimensional toroidal constant backgrounds and show that, up to third order in fluctuations, the theory coincides with the corresponding effective theory of the bosonic string compactified on n-dimensional toroidal constant backgrounds, obtained from three-point amplitudes. The comparison between both theories is facilitated by noticing that generalized diffeomorphisms in DFT allow to fix generalized harmonic gauge conditions that help in identifying the physical degrees of freedom. These conditions manifest as conformal anomaly cancellation requirements on the string theory side. The explicit expression for the gauge invariant effective action containing the physical massless sector (gravity+antisymmetric+gauge+ scalar fields) coupled to towers of generalized Kaluza Klein massive states (corresponding to compact momentum and winding modes) is found. The action acquires a very compact form when written in terms of fields carrying O( n, n) indices, and is explicitly T-duality invariant. The global algebra associated to the generalized Kaluza Klein compactification is discussed.

  14. Probing a Device's Active Atoms.

    Science.gov (United States)

    Studniarek, Michał; Halisdemir, Ufuk; Schleicher, Filip; Taudul, Beata; Urbain, Etienne; Boukari, Samy; Hervé, Marie; Lambert, Charles-Henri; Hamadeh, Abbass; Petit-Watelot, Sebastien; Zill, Olivia; Lacour, Daniel; Joly, Loïc; Scheurer, Fabrice; Schmerber, Guy; Da Costa, Victor; Dixit, Anant; Guitard, Pierre André; Acosta, Manuel; Leduc, Florian; Choueikani, Fadi; Otero, Edwige; Wulfhekel, Wulf; Montaigne, François; Monteblanco, Elmer Nahuel; Arabski, Jacek; Ohresser, Philippe; Beaurepaire, Eric; Weber, Wolfgang; Alouani, Mébarek; Hehn, Michel; Bowen, Martin

    2017-05-01

    Materials science and device studies have, when implemented jointly as "operando" studies, better revealed the causal link between the properties of the device's materials and its operation, with applications ranging from gas sensing to information and energy technologies. Here, as a further step that maximizes this causal link, the paper focuses on the electronic properties of those atoms that drive a device's operation by using it to read out the materials property. It is demonstrated how this method can reveal insight into the operation of a macroscale, industrial-grade microelectronic device on the atomic level. A magnetic tunnel junction's (MTJ's) current, which involves charge transport across different atomic species and interfaces, is measured while these atoms absorb soft X-rays with synchrotron-grade brilliance. X-ray absorption is found to affect magnetotransport when the photon energy and linear polarization are tuned to excite FeO bonds parallel to the MTJ's interfaces. This explicit link between the device's spintronic performance and these FeO bonds, although predicted, challenges conventional wisdom on their detrimental spintronic impact. The technique opens interdisciplinary possibilities to directly probe the role of different atomic species on device operation, and shall considerably simplify the materials science iterations within device research. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Probing QCD at high energy

    CERN Document Server

    Voutilainen, Mikko

    2012-01-01

    We review recent experimental work on probing QCD at high $p_{T}$ at the Tevatron and at the LHC. The Tevatron has just finished a long and illustrious career at the forefront of high energy physics, while the LHC now has its physics program in full swing and is producing results at a quick rate in a new energy regime. Many of the LHC measurements extend well into the TeV range, with potential sensitivity to new physics. The experimental systematics at the LHC are also becoming competitive with the Tevatron, making precision measurements of QCD possible. Measurements of inclusive jet, dijet and isolated prompt photon production can be used to test perturbative QCD predictions and to constrain parton distribution functions, as well as to measure the strong coupling constant. More exclusive topologies are used to constrain aspects of parton shower modeling, initial and final state radiation. Interest in boosted heavy resonances has resulted in novel studies of jet mass and subjet structure that also test pertu...

  16. Gravity Probe B Gyroscope Rotor

    Science.gov (United States)

    2003-01-01

    The Gravity Probe B (GP-B) is the relativity experiment developed at Stanford University to test two extraordinary predictions of Albert Einstein's general theory of relativity. The experiment will measure, very precisely, the expected tiny changes in the direction of the spin axes of four gyroscopes contained in an Earth-orbiting satellite at a 400-mile altitude. So free are the gyroscopes from disturbance that they will provide an almost perfect space-time reference system. They will measure how space and time are very slightly warped by the presence of the Earth, and, more profoundly, how the Earth's rotation very slightly drags space-time around with it. These effects, though small for the Earth, have far-reaching implications for the nature of matter and the structure of the Universe. This photograph is a close up of a niobium-coated gyroscope motor and its housing halves. GP-B is among the most thoroughly researched programs ever undertaken by NASA. This is the story of a scientific quest in which physicists and engineers have collaborated closely over many years. Inspired by their quest, they have invented a whole range of technologies that are already enlivening other branches of science and engineering. Launched April 20, 2004 , the GP-B program was managed for NASA by the Marshall Space Flight Center. Development of the GP-B is the responsibility of Stanford University along with major subcontractor Lockheed Martin Corporation. (Image credit to Don Harley.)

  17. Probing Light Stops with Stoponium

    CERN Document Server

    Batell, Brian

    2015-01-01

    We derive new limits on light stops from diboson resonance searches in the $\\gamma\\gamma$, $Z \\gamma$, $ZZ$, $WW$ and $hh$ channels from the first run of the LHC. If the two-body decays of the light stop are mildly suppressed or kinematically forbidden, stoponium bound states will form in $pp$ collisions and subsequently decay via the pair annihilation of the constituent stops to diboson final states, yielding striking resonance signatures. Remarkably, we find that stoponium searches are highly complementary to direct collider searches and indirect probes of light stops such as Higgs coupling measurements. Using an empirical quarkonia potential model and including the first two $S$-wave stoponium states, we find that in the decoupling limit $m_{\\widetilde t_1} \\lesssim 130$ GeV is excluded for any value of the stop mixing angle and heavy stop mass by the combination of the latest resonance searches and the indirect constraints. The $\\gamma \\gamma$ searches are the most complementary to the indirect constraint...

  18. Accuracy of probing attachment levels using a new computerized cemento-enamel junction probe.

    Science.gov (United States)

    Deepa, R; Prakash, Shobha

    2012-01-01

    The assessment of clinical attachment level (CAL) represents the gold standard for diagnosing and monitoring periodontal disease. The aim of the present study was to evaluate the performance of the newly introduced cemento-enamel junction (CEJ) probe in detecting CAL, using CEJ as a fixed reference point, and to compare the CEJ probe with the Florida stent probe (FSP) as well as with a standard manual probe, University of North Carolina-15 (UNC-15). Three examiners recorded the probing attachment level in 384 sites in case group (chronic periodontitis), and in 176 sites, in control group (healthy periodontal status), using the three probes. Subjects included both the sexes and ranged from 35 to 45 years. The experimental design was structured to balance the intra- and inter-examiner consistency at the same site during the two visits. CEJ probe showed higher intra-and inter-examiner consistency over both FSP and UNC-15 in both the case and control groups. Frequency distribution of differences of various magnitudes of repeated measurements ≤1 mm was in the higher range of 86.8% to 87.5% for CEJ probe. The FSP was more reproducible than UNC-15 in detecting relative attachment level (RAL). CEJ automated probe was found to have greatest potential for accuracy and consistency in detecting CAL than FSP and UNC-15. The automated probes appeared to be more reproducible than manual probes.

  19. Ad-hoc and context-dependent adjustments of selective attention in conflict control: an ERP study with visual probes.

    Science.gov (United States)

    Nigbur, R; Schneider, J; Sommer, W; Dimigen, O; Stürmer, B

    2015-02-15

    Cognitive conflict control in flanker tasks has often been described using the zoom-lens metaphor of selective attention. However, whether and how selective attention - in terms of suppression and enhancement - operates in this context has remained unclear. To examine the dynamic interplay of selective attention and cognitive control we used electrophysiological measures and presented task-irrelevant visual probe stimuli at foveal, parafoveal, and peripheral display positions. Target-flanker congruency varied either randomly from trial to trial (mixed-block) or block-wise (fixed-block) in order to induce reactive versus proactive control modes, respectively. Three EEG measures were used to capture ad-hoc adjustments within trials as well as effects of context-based predictions: the N1 component of the visual evoked potential (VEP) to probes, the VEP to targets, and the conflict-related midfrontal N2 component. Results from probe-VEPs indicate that enhanced processing of the foveal target rather than suppression of the peripheral flankers supports interference control. In incongruent mixed-block trials VEPs were larger to probes near the targets. In the fixed-blocks probe-VEPs were not modulated, but contrary to the mixed-block the preceding target-related VEP was affected by congruency. Results of the control-related N2 reveal largest amplitudes in the unpredictable context, which did not differentiate for stimulus and response incongruency. In contrast, in the predictable context, N2 amplitudes were reduced overall and differentiated between stimulus and response incongruency. Taken together these results imply that predictability alters interference control by a reconfiguration of stimulus processing. During unpredictable sequences participants adjust their attentional focus dynamically on a trial-by-trial basis as reflected in congruency-dependent probe-VEP-modulation. This reactive control mode also elicits larger N2 amplitudes. In contrast, when task demands

  20. Managing probe applications effectively? The process of pre-commercial fuel cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, H.L. [Delft Univ. of Technology, Delft (Netherlands)

    2007-07-01

    There has been a high degree of uncertainty regarding market adoption of proton exchange membrane (PEM) fuel cell technologies, making it challenging for fuel cell firms to determine which markets to pursue at which point in time. Probes, such as prototypes, demonstrations and field trials, are market experiments conducted by fuel cell firms and industry that are central to the commercialization of fuel cell technology. However, demonstration projects are extremely resource and time intensive, and outcomes are uncertain. This paper reviewed innovation management literature on the characteristics of the technology application process. Case study research of four fuel cell firms were discussed in terms of probe objectives and outcomes. An analysis of probe application patterns over time was also presented. Several fuel cell projects were also analyzed in terms of motivations and lessons learned. The paper focused on young independent fuel cell developers that had limited resources to allocate and waste resources on ineffective probe applications. The findings complement prior research that have found probe applications a valuable tool for learning, stimulating market demand and network formation. The paper made several recommendations regarding the main objectives of the fuel cell project, to set realistic goals and align expectations between consortia members. In addition, it was found that a short term demonstration project may appear to be an attractive application, but a project with a longer term vision and a commercial value proposition was more likely to attract stakeholders. 16 refs., 3 figs.

  1. The COLOFOL trial

    DEFF Research Database (Denmark)

    Hansdotter Andersson, Pernilla; Wille-Jørgensen, Peer; Horváth-Puhó, Erzsébet

    2016-01-01

    INTRODUCTION: The COLOFOL trial, a prospective randomized multicenter trial comparing two follow-up regimes after curative surgical treatment for colorectal cancer, focuses on detection of asymptomatic recurrences. This paper aims to describe the design and recruitment procedure in the COLOFOL...... trial, comparing demographic characteristics between randomized patients and eligible patients not included in the study. MATERIALS AND METHODS: COLOFOL was designed as a pragmatic trial with wide inclusion criteria and few exclusion criteria, in order to obtain a sample reflecting the general patient...

  2. Beyond trial types.

    Science.gov (United States)

    Dyrholm, Mads; Vangkilde, Signe; Bundesen, Claus

    2015-05-01

    Conventional wisdom on psychological experiments has held that when one or more independent variables are manipulated it is essential that all other conditions are kept constant such that confounding factors can be assumed negligible (Woodworth, 1938). In practice, the latter assumption is often questionable because it is generally difficult to guarantee that all other conditions are constant between any two trials. Therefore, the most common way to check for confounding violations of this assumption is to split the experimental conditions in terms of "trial types" to simulate a reduction of unintended trial-by-trial variation. Here, we pose a method which is more general than the use of trial types: use of mathematical models treating measures of potentially confounding factors and manipulated variables as equals on the single-trial level. We show how the method can be applied with models that subsume under the generalized linear item response theory (GLIRT), which is the case for most of the well-known psychometric models (Mellenbergh, 1994). As an example, we provide a new analysis of a single-letter recognition experiment using a nested likelihood ratio test that treats manipulated and measured variables equally (i.e., in exactly the same way) on the single-trial level. The test detects a confounding interaction with time-on-task as a single-trial measure and yields a substantially better estimate of the effect size of the main manipulation compared with an analysis made in terms of trial types.

  3. Comparative analyses of plasma probe diagnostics techniques

    Energy Technology Data Exchange (ETDEWEB)

    Godyak, V. A. [Electrical Engineering and Computer Science Department, University of Michigan, Ann Arbor, Michigan 48109, USA and RF Plasma Consulting, Brookline, Massachusetts 02446 (United States); Alexandrovich, B. M. [Plasma Sensors, Brookline, Massachusetts 02446 (United States)

    2015-12-21

    The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.

  4. Probe Project Status and Accomplishments - Year Two

    Energy Technology Data Exchange (ETDEWEB)

    Burris, R.D.

    2002-04-11

    The Probe project has established a facility for storage- and network-related research, development and testing. With sites at the Oak Ridge National Laboratory (ORNL) and the National Energy Research Scientific Computing Center (NERSC), Probe is investigating local-area or wide-area distributed storage issues ranging from data mining to optimizing retrieval operations from tape devices. Probe has completed its second full year of operation. In this document we will describe the status of the project as of December 31, 2001. This year we will structure this document by category of work, rather than by project status. We will present sections describing Scientific Discovery through Advanced Computation (SciDAC) projects, network research and research on data mining and distributed cluster analysis. Another section will describe data-transfer application development and testing and other types of hardware- and software-related testing and development activities. We will then describe the work undertaken for presentation at the SC2001 conference. The final section will summarize this year's publications. Individual projects described in this document have used some Probe resource--equipment, software, staff or funding. By describing these projects we do not imply that the work should be entirely credited to Probe, although we do assert that Probe's existence and assistance provided benefit to the work. The Probe project is funded by the Mathematical, Information, and Computer Sciences (MICS) department of the Advanced Scientific Computing Research office, Office of Science, Department of Energy.

  5. Probing Signal Design for Power System Identification

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, John W.; Zhou, Ning; Tuffner, Francis K.; Hauer, John F.; Trudnowski, Daniel J.; Mittelstadt, William

    2010-05-31

    This paper investigates the design of effective input signals for low-level probing of power systems. In 2005, 2006, and 2008 the Western Electricity Coordinating Council (WECC) conducted four large-scale system wide tests of the western interconnected power system where probing signals were injected by modulating the control signal at the Celilo end of the Pacific DC intertie. A major objective of these tests is the accurate estimation of the inter-area electromechanical modes. A key aspect of any such test is the design of an effective probing signal that leads to measured outputs rich in information about the modes. This paper specifically studies low-level probing signal design for power-system identification. The paper describes the design methodology and the advantages of this new probing signal which was successfully applied during these tests. This probing input is a multi-sine signal with its frequency content focused in the range of the inter-area modes. The period of the signal is over two minutes providing high-frequency resolution. Up to 15 cycles of the signal are injected resulting in a processing gain of 15. The resulting system response is studied in the time and frequency domains. Because of the new probing signal characteristics, these results show significant improvement in the output SNR compared to previous tests.

  6. Hyperpolarized NMR Probes for Biological Assays

    Directory of Open Access Journals (Sweden)

    Sebastian Meier

    2014-01-01

    Full Text Available During the last decade, the development of nuclear spin polarization enhanced (hyperpolarized molecular probes has opened up new opportunities for studying the inner workings of living cells in real time. The hyperpolarized probes are produced ex situ, introduced into biological systems and detected with high sensitivity and contrast against background signals using high resolution NMR spectroscopy. A variety of natural, derivatized and designed hyperpolarized probes has emerged for diverse biological studies including assays of intracellular reaction progression, pathway kinetics, probe uptake and export, pH, redox state, reactive oxygen species, ion concentrations, drug efficacy or oncogenic signaling. These probes are readily used directly under natural conditions in biofluids and are often directly developed and optimized for cellular assays, thus leaving little doubt about their specificity and utility under biologically relevant conditions. Hyperpolarized molecular probes for biological NMR spectroscopy enable the unbiased detection of complex processes by virtue of the high spectral resolution, structural specificity and quantifiability of NMR signals. Here, we provide a survey of strategies used for the selection, design and use of hyperpolarized NMR probes in biological assays, and describe current limitations and developments.

  7. Development and application of DNA molecular probes

    Directory of Open Access Journals (Sweden)

    Priya Vizzini

    2017-02-01

    Full Text Available The development of DNA probes started from 1950's for diagnostic purposes and it is still growing. DNA probes are applied in several fields such as food, medical, veterinary, environment and security, with the aim of prevention, diagnosis and treatment. The use of DNA probes permits microorganism identification, including pathogen detection, and their quantification when used in specific systems. Various techniques obtained success by the utilization of specific DNA probes, that allowed the obtainment of rapid and specific results. From PCR, qPCR and blotting techniques that were first used in well equipped laboratories to biosensors such as fiber optic, surface plasmon resonance (SPR, electrochemical, and quartz crystal microbalance (QCM biosensors that use different transduction systems. This review describes i the design and production of primers and probes, and their utilization from the traditional techniques to the new emerging techniques like biosensors used in current applications; ii the possibility to use labelled-free probes and probes labelled with an enzyme/fluorophore, etc.; iii the different sensitivity obtained by using specific systems; and iv the advantage obtained by using biosensors.

  8. FY16 Status of Immersion Phased Array Ultrasonic Probe Development and Performance Demonstration Results for Under Sodium Viewing

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Aaron A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chamberlin, Clyde E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Edwards, Matthew K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hagge, Tobias J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hughes, Michael S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Larche, Michael R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mathews, Royce A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Neill, Kevin J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Prowant, Matthew S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-08-31

    This section of the Joint summary technical letter report (TLR) describes work conducted at the Pacific Northwest National Laboratory (PNNL) during FY 2016 (FY16) on the under-sodium viewing (USV) PNNL project 58745, work package AT-16PN230102. This section of the TLR satisfies PNNL’s M3AT-16PN2301025 milestone and is focused on summarizing the design, development, and evaluation of two different phased-array ultrasonic testing (PA-UT) probe designs—a two-dimensional (2D) matrix phased-array probe, and two one-dimensional (1D) linear array probes, referred to as serial number 4 (SN4) engineering test units (ETUs). The 2D probe is a pulse-echo (PE), 32×2, 64-element matrix phased-array ETU. The 1D probes are 32×1 element linear array ETUs. This TLR also provides the results from a performance demonstration (PD) of in-sodium target detection trials at 260°C using both probe designs. This effort continues the iterative evolution supporting the longer term goal of producing and demonstrating a pre-manufacturing prototype ultrasonic probe that possesses the fundamental performance characteristics necessary to enable the development of a high-temperature sodium-cooled fast reactor (SFR) inspection system for in-sodium detection and imaging.

  9. Coke state determination in the blast furnace hearth using a tuyere probe

    Energy Technology Data Exchange (ETDEWEB)

    Negro, P.; Pierret, H.; Steiler, J. [and others] [Institut de Recherches de la Siderurgie Francaise (IRSID), Saint-Germain-en-Laye (France)

    1996-11-01

    Coke samplings at blast furnace tuyeres are a powerful means to study the behaviour of the lower part of the furnace. A tuyere probe has been installed since April 1985 on the BF2 at Sollac Fos. This probe is 19 m long and 11 tons in weight. It uses a 265 mm internal diameter pipe which samples materials in the centre of the BF. Up to now, 28 trials have been completed. The results obtained allow: a better understanding of the phenomena occurring in the blast furnace hearth, to establish several relationships between the internal state of the hearth and operation conditions, to build and validate a new image of the cohesive zone and the coke state, to measure and understand the influence of coal injection on the BF operation. Since April 1991, a movable tuyere probe has been in operation within Usinor Sacilor Group. This machine is lighter than the fixed one weighing only 5.5 tons and smaller measuring 5 m long for 1.3 m width. The probe is a 260 mm internal diameter pipe which can be introduced 4.25 m into the furnace. In 20 months, more than 40 coke core borings have been achieved on 9 different furnaces in 4 different plants. These two probes are complementary. The fixed probe is only used through one tuyere of one BF. In addition, this probe can reach the centre of the furnace and give a complete description of the materials present along the radius. The movable machine cannot reach the centre of the BF, but it enables the study of: some very different BF operating conditions, the influence of the feed materials qualities in a large range, the heterogeneity between several tuyeres of one BF, and the effect of the BF size. This paper presents an approach in coke quality research, relying upon the results of coke core borings.

  10. Parallel scanning probe arrays: their applications

    Directory of Open Access Journals (Sweden)

    Chang Liu

    2008-01-01

    Full Text Available Since the invention of the scanning tunneling microscope (STM1 and the atomic force microscope (AFM2, the field of scanning probe microscopy (SPM instruments has grown steadily and has had a profound influence in materials research, chemistry, biology, nanotechnology, and electronics3,4. Today, scanning probe instruments are used for metrology, characterization5, detection6, manipulation7, patterning8,9, and material modification. A wide range of scanning probe applications are available, taking advantage of various modes of tip–substrate interactions, including force, optics10,11, electrochemistry12, electromagnetics, electrostatics, thermal and mass transfer13,14, and vibration15,16.

  11. Electrostatic Probe with Shielded Probe Insulator Tube for Low Disturbing Plasma Measurements in Hall Thrusters

    Energy Technology Data Exchange (ETDEWEB)

    D. Staack, Y. Raitses, and N.J. Fisch

    2003-07-10

    Electrostatic probes are widely used to measure spatial plasma parameters of the quasi-neutral plasma in Hall thrusters and similar ExB electric discharge devices. Significant perturbations of the plasma, induced by such probes, can mask the actual physics involved in operation of these devices. In Hall thrusters, probe-induced perturbations can produce changes in the discharge current and plasma parameters on the order of their steady state values. These perturbations are explored by varying the material, penetration distance, and residence time of various probe designs. A possible cause of these perturbations appears to be the secondary electron emission, induced by energetic plasma electrons, from insulator ceramic tubes in which the probe wire is inserted. A new probe in which a low secondary electron emission material, such as metal, shields the probe ceramic tube, is shown to function without producing such large perturbations. A segmentation of this shield further prevents probe -induced perturbations, by not shortening the plasma through the conductive shield. In a set of experiments with a segmented shield probe, the thruster was operated in the input power range of 500-2.5 kW and discharge voltages of 200-500 V, while the probe-induced perturbations of the discharge current were below 4% of its steady state value in the region in which 90% of the voltage drop takes place.

  12. Full information acquisition in scanning probe microscopy and spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jesse, Stephen; Belianinov, Alex; Kalinin, Sergei V.; Somnath, Suhas

    2017-04-04

    Apparatus and methods are described for scanning probe microscopy and spectroscopy based on acquisition of full probe response. The full probe response contains valuable information about the probe-sample interaction that is lost in traditional scanning probe microscopy and spectroscopy methods. The full probe response is analyzed post data acquisition using fast Fourier transform and adaptive filtering, as well as multivariate analysis. The full response data is further compressed to retain only statistically significant components before being permanently stored.

  13. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... disease or prevent a disease from returning. Supportive Care Trials In supportive care trials, researchers look for ways to make life ... groups, and various types of social interventions. Supportive care interventions are not intended to treat or cure ...

  14. Comparability of prostate trials

    DEFF Research Database (Denmark)

    Suciu, S; Sylvester, R; Iversen, P

    1993-01-01

    The present overview of advanced prostate cancer required the identification of randomized clinical trials studying the question of maximal androgen blockade versus the classic castration therapy. The heterogeneity of the trials concerned the type of castration (surgical or chemical) and the type...

  15. Conductivity Probe after Trench-Bottom Placement

    Science.gov (United States)

    2008-01-01

    Needles of the thermal and conductivity probe on NASA's Phoenix Mars Lander were positioned into the bottom of a trench called 'Upper Cupboard' during Sol 86 (Aug. 21, 2008), or 86th Martian day after landing. This image of the conductivity probe after it was raised back out of the trench was taken by Phoenix's Robotic Arm Camera. The conductivity probe is at the wrist of the robotic arm's scoop. The probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  16. Modulated microwave microscopy and probes used therewith

    Science.gov (United States)

    Lai, Keji; Kelly, Michael; Shen, Zhi-Xun

    2012-09-11

    A microwave microscope including a probe tip electrode vertically positionable over a sample and projecting downwardly from the end of a cantilever. A transmission line connecting the tip electrode to the electronic control system extends along the cantilever and is separated from a ground plane at the bottom of the cantilever by a dielectric layer. The probe tip may be vertically tapped near or at the sample surface at a low frequency and the microwave signal reflected from the tip/sample interaction is demodulated at the low frequency. Alternatively, a low-frequency electrical signal is also a non-linear electrical element associated with the probe tip to non-linearly interact with the applied microwave signal and the reflected non-linear microwave signal is detected at the low frequency. The non-linear element may be semiconductor junction formed near the apex of the probe tip or be an FET formed at the base of a semiconducting tip.

  17. Pneumatic Proboscis Heat Flow Probe Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The heat flow probe directly answers requirements in the topic: S1.11 Lunar Science Instruments and Technology: "Geophysical Measurements: Systems, subsystems, and...

  18. Active miniature radio frequency field probe

    Directory of Open Access Journals (Sweden)

    A. Glasmachers

    2003-01-01

    Full Text Available For the measuring of the electromagnetic interference (e.g. on men of RF fields produced by mobile communication equipment field probes are required with high spatial resolution and high sensitivity. Available passive probes show good results with respect to bandwidth and low field distortion, but do not provide the required sensitivity and dynamic range. A significant limitation for active miniature probes is the power supply problem, because batteries cannot be used. Therefore the effect of high impedance connection lines is examined by a numerical field simulation. Different approaches for the design of an active probe are discussed, a favourable solution with a logarithmic demodulator is implemented and measuring results are presented.

  19. China's Reconfigurable Planet Probing Robot

    Institute of Scientific and Technical Information of China (English)

    RenShufang

    2005-01-01

    Research of reconfigurable planet probing robot conducted by the Shenyang Institute of Automation of the Chinese Academy of Science (SIA-CAS) has passed appraisal of 863 Program sresearch on intelligent robots.

  20. Probing plasmonic nanostructures by photons and electrons

    DEFF Research Database (Denmark)

    Kneipp, Katrin; Kneipp, Harald; Kneipp, Janina

    2015-01-01

    We discuss recent developments for studying plasmonic metal nanostructures. Exploiting photons and electrons opens up new capabilities to probe the complete plasmon spectrum including bright and dark modes and related local optical fields at subnanometer spatial resolution. This comprehensive...

  1. Development of DNA probes for Candida albicans

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, L.L.; Hudson, J.B.

    1988-07-01

    An attempt was made to produce DNA probes that could be used as a rapid and efficient means of detecting candidiasis (invasive Candida infection) in immunocompromised patients. Whole DNA from Candida albicans was digested with restriction endonuclease, and the resulting fragments were randomly cloned into a plasmid vector. Several recombinant plasmids were evaluated for cross-hybridization to various other Candida species, other fungal DNAs, and to nonfungal DNAs. Cross reactions were observed between the probes and different yeasts, but none with unrelated DNAs. Some recombinants were genus-specific, and two of these were applied to the analysis of C. albicans growth curves. It became evident that, although both /sup 32/P- and biotin-labelled probes could be made quite sensitive, a possible limitation in their diagnostic potential was the poor liberation of Candida DNA from cells. Thus, better methods of treatment of clinical specimens will be required before such probes will be useful in routine diagnosis.

  2. Introduction to fluorescence probing of biological membranes.

    Science.gov (United States)

    Demchenko, Alexander P; Duportail, Guy; Oncul, Sule; Klymchenko, Andrey S; Mély, Yves

    2015-01-01

    Fluorescence is one of the most powerful and commonly used tools in biophysical studies of biomembrane structure and dynamics that can be applied on different levels, from lipid monolayers and bilayers to living cells, tissues, and whole animals. Successful application of this method relies on proper design of fluorescence probes with optimized photophysical properties. These probes are efficient for studying the microscopic analogs of viscosity, polarity, and hydration, as well as the molecular order, environment relaxation, and electrostatic potentials at the sites of their location. Being smaller than the membrane width they can sense the gradients of these parameters across the membrane. We present examples of novel dyes that achieve increased spatial resolution and information content of the probe responses. In this respect, multiparametric environment-sensitive probes feature considerable promise.

  3. Angular response of hot wire probes

    Science.gov (United States)

    di Mare, L.; Jelly, T. O.; Day, I. J.

    2017-03-01

    A new equation for the convective heat loss from the sensor of a hot-wire probe is derived which accounts for both the potential and the viscous parts of the flow past the prongs. The convective heat loss from the sensor is related to the far-field velocity by an expression containing a term representing the potential flow around the prongs, and a term representing their viscous effect. This latter term is absent in the response equations available in the literature but is essential in representing some features of the observed response of miniature hot-wire probes. The response equation contains only four parameters but it can reproduce, with great accuracy, the behaviour of commonly used single-wire probes. The response equation simplifies the calibration the angular response of rotated slanted hot-wire probes: only standard King’s law parameters and a Reynolds-dependent drag coefficient need to be determined.

  4. Phoenix Conductivity Probe Inserted into Martian Soil

    Science.gov (United States)

    2008-01-01

    NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008). The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 while the probe's needles were in the ground. The science team informally named this soil target 'Gandalf.' The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  5. Surface sampling concentration and reaction probe

    Science.gov (United States)

    Van Berkel, Gary J; Elnaggar, Mariam S

    2013-07-16

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  6. Sapphire Viewports for a Venus Probe Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase 1 program will demonstrate that sapphire viewports are feasible for use in Venus probes. TvU's commercial viewport products have demonstrated that...

  7. Automated design of genomic Southern blot probes

    Directory of Open Access Journals (Sweden)

    Komiyama Noboru H

    2010-01-01

    Full Text Available Abstract Background Sothern blotting is a DNA analysis technique that has found widespread application in molecular biology. It has been used for gene discovery and mapping and has diagnostic and forensic applications, including mutation detection in patient samples and DNA fingerprinting in criminal investigations. Southern blotting has been employed as the definitive method for detecting transgene integration, and successful homologous recombination in gene targeting experiments. The technique employs a labeled DNA probe to detect a specific DNA sequence in a complex DNA sample that has been separated by restriction-digest and gel electrophoresis. Critically for the technique to succeed the probe must be unique to the target locus so as not to cross-hybridize to other endogenous DNA within the sample. Investigators routinely employ a manual approach to probe design. A genome browser is used to extract DNA sequence from the locus of interest, which is searched against the target genome using a BLAST-like tool. Ideally a single perfect match is obtained to the target, with little cross-reactivity caused by homologous DNA sequence present in the genome and/or repetitive and low-complexity elements in the candidate probe. This is a labor intensive process often requiring several attempts to find a suitable probe for laboratory testing. Results We have written an informatic pipeline to automatically design genomic Sothern blot probes that specifically attempts to optimize the resultant probe, employing a brute-force strategy of generating many candidate probes of acceptable length in the user-specified design window, searching all against the target genome, then scoring and ranking the candidates by uniqueness and repetitive DNA element content. Using these in silico measures we can automatically design probes that we predict to perform as well, or better, than our previous manual designs, while considerably reducing design time. We went on to

  8. Chemical Address Tags of Fluorescent Bioimaging Probes

    OpenAIRE

    Shedden, Kerby; Rosania, Gus R.

    2010-01-01

    Chemical address tags can be defined as specific structural features shared by a set of bioimaging probes having a predictable influence on cell-associated visual signals obtained from these probes. Here, using a large image dataset acquired with a high content screening instrument, machine vision and cheminformatics analysis have been applied to reveal chemical address tags. With a combinatorial library of fluorescent molecules, fluorescence signal intensity, spectral, and spatial features c...

  9. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples...... the probe spacing is smaller than 1/40 of the variation wavelength, micro four-point probes can provide an accurate record of local properties with less than 1% measurement error. All the calculations agree well with previous experimental results.......) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the local variations. The calculations show that the measurement error is highly dependent on the probe spacing. When...

  10. Fast and reliable method of conductive carbon nanotube-probe fabrication for scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dremov, Vyacheslav, E-mail: dremov@issp.ac.ru; Fedorov, Pavel; Grebenko, Artem [Institute of Solid State Physics, RAS, 142432 Chernogolovka (Russian Federation); Interdisciplinary Center for Basic Research, Moscow Institute of Physics and Technology, 141700 Dolgoprudniy (Russian Federation); Fedoseev, Vitaly [Institute of Solid State Physics, RAS, 142432 Chernogolovka (Russian Federation)

    2015-05-15

    We demonstrate the procedure of scanning probe microscopy (SPM) conductive probe fabrication with a single multi-walled carbon nanotube (MWNT) on a silicon cantilever pyramid. The nanotube bundle reliably attached to the metal-covered pyramid is formed using dielectrophoresis technique from the MWNT suspension. It is shown that the dimpled aluminum sample can be used both for shortening/modification of the nanotube bundle by applying pulse voltage between the probe and the sample and for controlling the probe shape via atomic force microscopy imaging the sample. Carbon nanotube attached to cantilever covered with noble metal is suitable for SPM imaging in such modulation regimes as capacitance contrast microscopy, Kelvin probe microscopy, and scanning gate microscopy. The majority of such probes are conductive with conductivity not degrading within hours of SPM imaging.

  11. Phoenix Conductivity Probe with Shadow and Toothmark

    Science.gov (United States)

    2008-01-01

    NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008). The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 after the probe was lifted away from the soil. The imprint left by the insertion is visible below the probe, and a shadow showing the probe's four needles is cast on a rock to the left. The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  12. The Hera Saturn Entry Probe Mission

    CERN Document Server

    Mousis, O; Spilker, T; Venkatapathy, E; Poncy, J; Frampton, R; Coustenis, A; Reh, K; Lebreton, J -P; Fletcher, L N; Hueso, R; Amato, M J; Colaprete, A; Ferri, F; Stam, D; Wurz, P; Atreya, S; Aslam, S; Banfield, D J; Calcutt, S; Fischer, G; Holland, A; Keller, C; Kessler, E; Leese, M; Levacher, P; Morse, A; Munoz, O; Renard, J -B; Sheridan, S; Schmider, F -X; Snik, F; Waite, J H; Bird, M; Cavalié, T; Deleuil, M; Fortney, J; Gautier, D; Guillot, T; Lunine, J I; Marty, B; Nixon, C; Orton, G S; Sanchez-Lavega, A

    2015-01-01

    The Hera Saturn entry probe mission is proposed as an M--class mission led by ESA with a contribution from NASA. It consists of one atmospheric probe to be sent into the atmosphere of Saturn, and a Carrier-Relay spacecraft. In this concept, the Hera probe is composed of ESA and NASA elements, and the Carrier-Relay Spacecraft is delivered by ESA. The probe is powered by batteries, and the Carrier-Relay Spacecraft is powered by solar panels and batteries. We anticipate two major subsystems to be supplied by the United States, either by direct procurement by ESA or by contribution from NASA: the solar electric power system (including solar arrays and the power management and distribution system), and the probe entry system (including the thermal protection shield and aeroshell). Hera is designed to perform in situ measurements of the chemical and isotopic compositions as well as the dynamics of Saturn's atmosphere using a single probe, with the goal of improving our understanding of the origin, formation, and ev...

  13. Language comprehension and probe-list memory.

    Science.gov (United States)

    Gordon, P C; Hendrick, R; Foster, K L

    2000-05-01

    Experiments were performed using probe-word recognition methodology in which participants read sentences that were presented 1 word at a time and were then shown a probe word and had to make a speeded response indicating whether the word had occurred in the sentence. One experiment showed that response times to probe words increased with the size of the set of candidate probes. The other experiments showed that the effects caused by name repetition in circumstances in which the repeated name was co-referential also occurred when the repeated name was not co-referential and when the order of words in a sentence was scrambled. The results suggest that responses in the task can be based on probe-list memory, a mental representation created to keep track of those words that the participant believes are likely to be probed, and that the use of the task to make inferences about language comprehension should be accompanied by controls ruling out such strategies.

  14. What Are Clinical Trial Phases?

    Medline Plus

    Full Text Available ... Trials Insurance Coverage and Clinical Trials How to Work With Your Health Insurance Plan Federal Government Programs Patient Safety Informed Consent Children's Assent Scientific Review Ending Trials Early Deciding to Take Part ...

  15. Tunable third-harmonic probe for non-degenerate ultrafast pump–probe measurements

    Indian Academy of Sciences (India)

    Asha Singh; Salahuddin Khan; Podili Sivasankaraiah; J Jayabalan; Rama Chari

    2014-02-01

    In this article, we report a method to achieve a precisely tunable highly stable probe beam generation for performing pump–probe experiment around a given wavelength by tilting a sum frequency generation (SFG) crystal angle. The width of the generated third-harmonic beam is of the order of 2 nm throughout the tunable range. This method of probe beam generation has its application in isolating contributions from closely separated excitation states.

  16. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    OpenAIRE

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard; Hansen, Ole

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the ...

  17. ProbeMaker: an extensible framework for design of sets of oligonucleotide probes

    Directory of Open Access Journals (Sweden)

    Nilsson Mats

    2005-09-01

    Full Text Available Abstract Background Procedures for genetic analyses based on oligonucleotide probes are powerful tools that can allow highly parallel investigations of genetic material. Such procedures require the design of large sets of probes using application-specific design constraints. Results ProbeMaker is a software framework for computer-assisted design and analysis of sets of oligonucleotide probe sequences. The tool assists in the design of probes for sets of target sequences, incorporating sequence motifs for purposes such as amplification, visualization, or identification. An extension system allows the framework to be equipped with application-specific components for evaluation of probe sequences, and provides the possibility to include support for importing sequence data from a variety of file formats. Conclusion ProbeMaker is a suitable tool for many different oligonucleotide design and analysis tasks, including the design of probe sets for various types of parallel genetic analyses, experimental validation of design parameters, and in silico testing of probe sequence evaluation algorithms.

  18. Verification of multiplex ligation-dependent probe amplification probes in the absence of positive samples.

    Science.gov (United States)

    Wooderchak-Donahue, Whitney; Vaughn, Cecily; Chou, Lan-Szu; Lewis, Tracey; Sumner, Kelli; Procter, Melinda; Gedge, Friederike; Bayrak-Toydemir, Pinar; Lyon, Elaine; Pont-Kingdon, Genevieve

    2011-11-01

    Deletions and duplications of single or multiple exons in specific genes are associated with human diseases. Multiplex ligation-dependant probe amplification (MLPA), a technique recently introduced to clinical laboratories, can detect deletions or duplications at the exon level. MLPA kits have a high multiplexing capability containing mixtures of exon-specific probes that target the gene of interest and control probes that hybridize to other genomic areas before PCR amplification. To verify each probe set, known positive samples with a single-exon deletion or duplication and normal samples are ideally used. Often, positive samples do not exist for each exon and normal samples are not suited to verify the identity of each probe set. We designed a straightforward approach using mixes of exon-specific PCR products as template to unequivocally verify each probe set in MLPA kits. This method can be used to verify the identity of MLPA probes for exons when positive samples are unavailable. Exon-specific probes from 15 MLPA kits were shown to hybridize to the targeted exons of interest. In one kit, this method identified probes that also bind a pseudogene, making them unreliable for clinical analysis. Incorporating this methodology in the analytical validation process will help ensure that MLPA results are interpreted correctly.

  19. Development of an autofluorescent probe for brain cancer: probe characterization thanks to phantom studies

    Science.gov (United States)

    Leh, B.; Charon, Y.; Duval, M.-A.; Lefebvre, F.; Linden, S.; Menard, L.; Siebert, R.

    2010-02-01

    Glioblastoma are brain tumors currently incurable, however, optimized treatment gives better prognosis and quality of life. In case of surgical treatment, there is still need to help surgeons to determine whether a tissue is tumorous or not. Within the framework of the design of a new autofluorescence probe for this issue, optically calibrated gel phantoms have been developed using "tumorous" inclusions in a "healthy" environment. Depending on "tumor" shape, size and localization, the sensitivity of the probe is evaluated. The probe sensitivity for fluorescence spectroscopy will be presented. The probe configuration is also taken into account and compared to simulated results.

  20. Fundamentals of clinical trials

    CERN Document Server

    Friedman, Lawrence M; DeMets, David L; Reboussin, David M; Granger, Christopher B

    2015-01-01

    This is the fifth edition of a very successful textbook on clinical trials methodology, written by recognized leaders who have long and extensive experience in all areas of clinical trials. The three authors of the first four editions have been joined by two others who add great expertise.  Most chapters have been revised considerably from the fourth edition.  A chapter on regulatory issues has been included and the chapter on data monitoring has been split into two and expanded.  Many contemporary clinical trial examples have been added.  There is much new material on adverse events, adherence, issues in analysis, electronic data, data sharing, and international trials.  This book is intended for the clinical researcher who is interested in designing a clinical trial and developing a protocol. It is also of value to researchers and practitioners who must critically evaluate the literature of published clinical trials and assess the merits of each trial and the implications for the care and treatment of ...

  1. Comparability of prostate trials

    DEFF Research Database (Denmark)

    Suciu, S; Sylvester, R; Iversen, P;

    1993-01-01

    The present overview of advanced prostate cancer required the identification of randomized clinical trials studying the question of maximal androgen blockade versus the classic castration therapy. The heterogeneity of the trials concerned the type of castration (surgical or chemical) and the type...... of antiandrogen (flutamide, Anandron, or cyproterone acetate) added to castration. This paper reviews the different types of heterogeneity that might exist among trials that are involved in the overview: study design, randomization procedure, treatment evaluation, statistical evaluation, and data maturity...... with a larger number of patients and a longer follow-up will contribute more to the overview's results....

  2. The Hera Saturn entry probe mission

    Science.gov (United States)

    Mousis, O.; Atkinson, D. H.; Spilker, T.; Venkatapathy, E.; Poncy, J.; Frampton, R.; Coustenis, A.; Reh, K.; Lebreton, J.-P.; Fletcher, L. N.; Hueso, R.; Amato, M. J.; Colaprete, A.; Ferri, F.; Stam, D.; Wurz, P.; Atreya, S.; Aslam, S.; Banfield, D. J.; Calcutt, S.; Fischer, G.; Holland, A.; Keller, C.; Kessler, E.; Leese, M.; Levacher, P.; Morse, A.; Muñoz, O.; Renard, J.-B.; Sheridan, S.; Schmider, F.-X.; Snik, F.; Waite, J. H.; Bird, M.; Cavalié, T.; Deleuil, M.; Fortney, J.; Gautier, D.; Guillot, T.; Lunine, J. I.; Marty, B.; Nixon, C.; Orton, G. S.; Sánchez-Lavega, A.

    2016-10-01

    The Hera Saturn entry probe mission is proposed as an M-class mission led by ESA with a contribution from NASA. It consists of one atmospheric probe to be sent into the atmosphere of Saturn, and a Carrier-Relay spacecraft. In this concept, the Hera probe is composed of ESA and NASA elements, and the Carrier-Relay Spacecraft is delivered by ESA. The probe is powered by batteries, and the Carrier-Relay Spacecraft is powered by solar panels and batteries. We anticipate two major subsystems to be supplied by the United States, either by direct procurement by ESA or by contribution from NASA: the solar electric power system (including solar arrays and the power management and distribution system), and the probe entry system (including the thermal protection shield and aeroshell). Hera is designed to perform in situ measurements of the chemical and isotopic compositions as well as the dynamics of Saturn's atmosphere using a single probe, with the goal of improving our understanding of the origin, formation, and evolution of Saturn, the giant planets and their satellite systems, with extrapolation to extrasolar planets. Hera's aim is to probe well into the cloud-forming region of the troposphere, below the region accessible to remote sensing, to the locations where certain cosmogenically abundant species are expected to be well mixed. By leading to an improved understanding of the processes by which giant planets formed, including the composition and properties of the local solar nebula at the time and location of giant planet formation, Hera will extend the legacy of the Galileo and Cassini missions by further addressing the creation, formation, and chemical, dynamical, and thermal evolution of the giant planets, the entire solar system including Earth and the other terrestrial planets, and formation of other planetary systems.

  3. Pneumatic Proboscis Heat-Flow Probe

    Science.gov (United States)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  4. Novel laser contact probe for periodontal treatment

    Science.gov (United States)

    Watanabe, Hisashi; Kataoka, Kenzo; Ishikawa, Isao

    2001-04-01

    Application of the erbium: YAG laser to periodontal treatment has been attempted and preferable results have been reported for calculus removal, vaporization of granulation tissue, periodontal pocket sterilization and so on. However, it has been difficult to reach and treat some conditions involving complex root morphology and furcated rots with conventional probes. The new broom probe was designed and tested to overcome these obstacles. The probe was made of 20 super-fine optical fibers bound into a broom shape. The experiments were carried out to evaluate the destructive power of a single fiber and to examine the morphology of tissue destruction and the accessibility to a bifurcated root of a human tooth using the broom probe. The Er:YAG laser prototype was used. A flat specimen plate was made by cutting the root of a cow tooth and then attached to an electrically operated table and irradiated under various conditions. The specimens were examined with both an optical and scanning electron microscope. The irradiated surfaces were also examined with a roughness meter. An irradiation applied with a single fiber with an energy level of 1 to 1.5 mJ at its tip results in a destruction depth of 3 to 24 micrometers . The optimum conditions for the fibers of this probe was 1.0 mJ at 10 pps and a scanning speed of 100 mm/min. No part of the tooth surface remained un-irradiated after using the broom probe to cover the surface 5 times parallel to the tooth axis and then five times at a 30 degree angle to the previous irradiation at a power of 20 mJ at 10 pps. Also curved and irregular surface were destroyed to a maximum depth of 19 micrometers . In conclusion, these results suggest that the broom probe would be applicable for periodontal laser treatments even if the tooth surface has a complex and irregular shape.

  5. Dual active surface heat flux gage probe

    Science.gov (United States)

    Liebert, Curt H.; Kolodziej, Paul

    1995-02-01

    A unique plug-type heat flux gage probe was tested in the NASA Ames Research Center 2x9 turbulent flow duct facility. The probe was fabricated by welding a miniature dual active surface heat flux gage body to the end of a hollow metal cylindrical bolt containing a metal inner tube. Cooling air flows through the inner tube, impinges onto the back of the gage body and then flows out through the annulus formed between the inner tube and the hollow bolt wall. Heat flux was generated in the duct facility with a Huels arc heater. The duct had a rectangular cross section and one wall was fabricated from 2.54 centimeter thick thermal insulation rigid surface material mounted onto an aluminum plate. To measure heat flux, the probe was inserted through the plate and insulating materials with the from of the gage located flush with the hot gas-side insulation surface. Absorbed heat fluxes measured with the probe were compared with absorbed heat fluxes measured with six water-cooled reference calorimeters. These calorimeters were located in a water-cooled metal duct wall which was located across from the probe position. Correspondence of transient and steady heat fluxes measured with the reference calorimeters and heat flux gage probe was generally within a satisfactory plus or minus 10 percent. This good correspondence was achieved even though the much cooler probe caused a large surface temperature disruption of 1000K between the metal gage and the insulation. However, this temperature disruption did not seriously effect the accuracy of the heat flux measurement. A current application for dual active surface heat flux gages is for transient and steady absorbed heat flux, surface temperature and heat transfer coefficient measurements on the surface of an oxidizer turbine inlet deflector operating in a space shuttle test bed engine.

  6. Inept media trials of clinical trials

    Directory of Open Access Journals (Sweden)

    N V Ramamurthy

    2012-01-01

    Full Text Available The Indian media in general, with the exception of a few domain expert journalists, have failed to comprehend the complexities involved in the clinical trial process. In the run up to the deadline-based coverage of a story, a majority of them fall short in conveying the right perspective to readers, but nevertheless they have been successful in sensationalizing an event in this arena. Possibly by unintended misrepresentation, or mostly out of ignorance of the nuances involved in the clinical trials process, the media has done more harm than good, and got away with it. On the other side, the industry has been reluctant to engage with the media in a meaningful dialog for too long now. It bears not only the consequences of damage to its professional reputation following such reportage, but also the repercussions of unnecessary clampdowns by the regulators. Science journalism in India has yet to rise as a profession.

  7. 21 CFR 870.2120 - Extravascular blood flow probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Extravascular blood flow probe. 870.2120 Section... blood flow probe. (a) Identification. An extravascular blood flow probe is an extravascular ultrasonic or electromagnetic probe used in conjunction with a blood flowmeter to measure blood flow in...

  8. Design and synthesis of paramagnetic probes for structural biology

    NARCIS (Netherlands)

    Liu, Wei-Min

    2013-01-01

    The majority of the work presented in this thesis involves the design and synthesis of paramagnetic NMR probes, including lanthanoids caged probes and spin labels. An overview of the development of different types of lanthanoids caged probes is given. Among all of the reported lanthanoid probes, the

  9. Nuclear probes and intraoperative gamma cameras.

    Science.gov (United States)

    Heller, Sherman; Zanzonico, Pat

    2011-05-01

    Gamma probes are now an important, well-established technology in the management of cancer, particularly in the detection of sentinel lymph nodes. Intraoperative sentinel lymph node as well as tumor detection may be improved under some circumstances by the use of beta (negatron or positron), rather than gamma detection, because the very short range (∼ 1 mm or less) of such particulate radiations eliminates the contribution of confounding counts from activity other than in the immediate vicinity of the detector. This has led to the development of intraoperative beta probes. Gamma camera imaging also benefits from short source-to-detector distances and minimal overlying tissue, and intraoperative small field-of-view gamma cameras have therefore been developed as well. Radiation detectors for intraoperative probes can generally be characterized as either scintillation or ionization detectors. Scintillators used in scintillation-detector probes include thallium-doped sodium iodide, thallium- and sodium-doped cesium iodide, and cerium-doped lutecium orthooxysilicate. Alternatives to inorganic scintillators are plastic scintillators, solutions of organic scintillation compounds dissolved in an organic solvent that is subsequently polymerized to form a solid. Their combined high counting efficiency for beta particles and low counting efficiency for 511-keV annihilation γ-rays make plastic scintillators well-suited as intraoperative beta probes in general and positron probes in particular Semiconductors used in ionization-detector probes include cadmium telluride, cadmium zinc telluride, and mercuric iodide. Clinical studies directly comparing scintillation and semiconductor intraoperative probes have not provided a clear choice between scintillation and ionization detector-based probes. The earliest small field-of-view intraoperative gamma camera systems were hand-held devices having fields of view of only 1.5-2.5 cm in diameter that used conventional thallium

  10. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... to obtain preliminary data on whether the drug works in people who have a certain disease or condition. These trials also continue to study safety, including short-term side effects. This phase ...

  11. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... out if an experimental drug, therapy, medical device, lifestyle change, or test will help treat, find, or ... specific medical problem. These trials find out if lifestyle changes, such as exercising more, getting more sleep, ...

  12. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... a disease. A clinical trial may compare experimental products or tests to those already available or may ... Institutes of Health | U.S. Department of Health & Human Services Customer Support | Accessibility | Copyright | Privacy | Viewers and Players

  13. OARSI Clinical Trials Recommendations

    DEFF Research Database (Denmark)

    Katz, J N; Losina, E; Lohmander, L S

    2015-01-01

    To highlight methodological challenges in the design and conduct of randomized trials of surgical interventions and to propose strategies for addressing these challenges. This paper focuses on three broad areas: enrollment; intervention; and assessment including implications for analysis. For eac...

  14. ClinicalTrials.gov

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provides patients, family members, health care professionals, and members of the public easy access to information on clinical trials for a wide range of diseases...

  15. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... new tests that could identify a disease in its early stages. Usually, trial participants must show signs ... often healthy people (20 to 80), to judge its safety and side effects, and to find the ...

  16. TRIAL BY PREVIEW

    National Research Council Canada - National Science Library

    Bert I. Huang

    2013-01-01

    ...—that is, the judge or the jury who will be the finder of fact at trial. Both theory and policy have focused narrowly on previewing the evidence, while barely noticing the complementary effect of previewing the audience...

  17. Polyp Prevention Trial

    Science.gov (United States)

    The primary objective of the Polyp Prevention Trial (PPT) is to determine whether a low fat, high fiber, high vegetable and fruit eating plan will decrease the recurrence of adenomatous polyps of the large bowel.

  18. Anchor Trial Launch

    Science.gov (United States)

    NCI has launched a multicenter phase III clinical trial called the ANCHOR Study -- Anal Cancer HSIL (High-grade Squamous Intraepithelial Lesion) Outcomes Research Study -- to determine if treatment of HSIL in HIV-infected individuals can prevent anal canc

  19. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... experimental drug, therapy, medical device, lifestyle change, or test will help treat, find, or prevent a disease. A clinical trial may compare experimental products or tests to those already available or may compare existing ...

  20. Soil Properties from Low-Velocity Probe Penetration

    Directory of Open Access Journals (Sweden)

    Jerome B. Johnson

    2008-01-01

    Full Text Available A physical model of low-velocity probe penetration is developed to characterize soil by type, strength, maximum compaction, and initial density using Newton's second law to describe the processes controlling probe momentum loss. The probe loses momentum by causing soil failure (strength, accelerating and compacting soil around the probe (inertia, and through frictional sliding at the probe/soil interface (friction. Probe geometry, mass, and impact velocity influences are incorporated into the model. Model predictions of probe deceleration history and depth of penetration agree well with experiments, without the need for free variables or complex numerical simulations.

  1. Formative Assessment Probes: Big and Small Seeds. Linking Formative Assessment Probes to the Scientific Practices

    Science.gov (United States)

    Keeley, Page

    2016-01-01

    This column focuses on promoting learning through assessment. Formative assessment probes are designed to uncover students' ideas about objects, events, and processes in the natural world. This assessment information is then used throughout instruction to move students toward an understanding of the scientific ideas behind the probes. During the…

  2. Formative Assessment Probes: Constructing Cl-Ev-R Explanations to Formative Assessment Probes

    Science.gov (United States)

    Keeley, Page

    2015-01-01

    A distinguishing feature of all the formative assessment probes in the "Uncovering Student Ideas" series is that each probe has two parts: (1) a selected answer choice that usually mirrors the research on commonly held ideas students have about concepts or phenomena; and (2) an explanation that supports their answer choice. It is this…

  3. In-vitro accuracy and reproducibility evaluation of probing depth measurements of selected periodontal probes

    Directory of Open Access Journals (Sweden)

    K.N. Al Shayeb

    2014-01-01

    Conclusion: Depth measurements with the Chapple UB-CF-15 probe were more accurate and reproducible compared to measurements with the Vivacare TPS and Williams 14 W probes. This in vitro model may be useful for intra-examiner calibration or clinician training prior to the clinical evaluation of patients or in longitudinal studies involving periodontal evaluation.

  4. Full silicon-nitride probes with corner lithography wireframes for scanning Hall probe microscopy

    NARCIS (Netherlands)

    Hatakeyama, K.; Sarajlic, E.; Siekman, M.H.; Huijink, R.; Abelmann, L.

    2012-01-01

    We present a improvement of our previous design of wireframe tips for scanning Hall probes. By doubling the separation between electrode structures and cantilever base, the yield could be raised from less than 10% to over 75%. To avoid build up of stress gradients, the entire probe is manufactured f

  5. Probing a composite spin-boson environment

    Energy Technology Data Exchange (ETDEWEB)

    Oxtoby, Neil P; Rivas, Angel; Huelga, Susana F [Quantum Physics Group, STRI, School of Physics, Astronomy and Mathematics, University of Hertfordshire, Hatfield, Herts AL10 9AB (United Kingdom); Fazio, Rosario [NEST CNR-INFM and Scuola Normale Superiore, Piazza dei Cavalieri 7, I-56126 Pisa (Italy)], E-mail: s.f.huelga@herts.ac.uk

    2009-06-15

    We consider non-interacting multi-qubit systems as controllable probes of an environment of defects/impurities modelled as a composite spin-boson environment. The spin-boson environment consists of a small number of quantum-coherent two-level fluctuators (TLFs) damped by independent bosonic baths. A master equation of the Lindblad form is derived for the probe-plus-TLF system. We discuss how correlation measurements in the probe system encode information about the environment structure and could be exploited to efficiently discriminate between different experimental preparation techniques, with particular focus on the quantum correlations (entanglement) that build up in the probe as a result of the TLF-mediated interaction. We also investigate the harmful effects of the composite spin-boson environment on initially prepared entangled bipartite qubit states of the probe and on entangling gate operations. Our results offer insights in the area of quantum computation using superconducting devices, where defects/impurities are believed to be a major source of decoherence.

  6. Approaches for drug delivery with intracortical probes.

    Science.gov (United States)

    Spieth, Sven; Schumacher, Axel; Trenkle, Fabian; Brett, Olivia; Seidl, Karsten; Herwik, Stanislav; Kisban, Sebastian; Ruther, Patrick; Paul, Oliver; Aarts, Arno A A; Neves, Hercules P; Rich, P Dylan; Theobald, David E; Holtzman, Tahl; Dalley, Jeffrey W; Verhoef, Bram-Ernst; Janssen, Peter; Zengerle, Roland

    2014-08-01

    Intracortical microprobes allow the precise monitoring of electrical and chemical signaling and are widely used in neuroscience. Microelectromechanical system (MEMS) technologies have greatly enhanced the integration of multifunctional probes by facilitating the combination of multiple recording electrodes and drug delivery channels in a single probe. Depending on the neuroscientific application, various assembly strategies are required in addition to the microprobe fabrication itself. This paper summarizes recent advances in the fabrication and assembly of micromachined silicon probes for drug delivery achieved within the EU-funded research project NeuroProbes. The described fabrication process combines a two-wafer silicon bonding process with deep reactive ion etching, wafer grinding, and thin film patterning and offers a maximum in design flexibility. By applying this process, three general comb-like microprobe designs featuring up to four 8-mm-long shafts, cross sections from 150×200 to 250×250 µm², and different electrode and fluidic channel configurations are realized. Furthermore, we discuss the development and application of different probe assemblies for acute, semichronic, and chronic applications, including comb and array assemblies, floating microprobe arrays, as well as the complete drug delivery system NeuroMedicator for small animal research.

  7. Chromosome-specific DNA Repeat Probes

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, Adolf; Weier, Jingly Fung; Weier, Heinz-Ulrich G.

    2006-03-16

    In research as well as in clinical applications, fluorescence in situ hybridization (FISH) has gained increasing popularity as a highly sensitive technique to study cytogenetic changes. Today, hundreds of commercially available DNA probes serve the basic needs of the biomedical research community. Widespread applications, however, are often limited by the lack of appropriately labeled, specific nucleic acid probes. We describe two approaches for an expeditious preparation of chromosome-specific DNAs and the subsequent probe labeling with reporter molecules of choice. The described techniques allow the preparation of highly specific DNA repeat probes suitable for enumeration of chromosomes in interphase cell nuclei or tissue sections. In addition, there is no need for chromosome enrichment by flow cytometry and sorting or molecular cloning. Our PCR-based method uses either bacterial artificial chromosomes or human genomic DNA as templates with {alpha}-satellite-specific primers. Here we demonstrate the production of fluorochrome-labeled DNA repeat probes specific for human chromosomes 17 and 18 in just a few days without the need for highly specialized equipment and without the limitation to only a few fluorochrome labels.

  8. Holographic backgrounds from D-brane probes

    CERN Document Server

    Moskovic, Micha

    2014-01-01

    This thesis focuses on the derivation of holographic backgrounds from the field theory side, without using any supergravity equations of motion. Instead, we rely on the addition of probe D-branes to the stack of D-branes generating the background. From the field theory description of the probe branes, one can compute an effective action for the probes (in a suitable low-energy/near-horizon limit) by integrating out the background branes. Comparing this action with the generic probe D-brane action then allows to determine the holographic background dual to the considered field theory vacuum. In the first part, the required pre-requisites of field and string theory are recalled and this strategy to derive holographic backgrounds is explained in more detail on the basic case of D3-branes in flat space probed by a small number of D-instantons. The second part contains our original results, which have already appeared in arXiv:1301.3738, arXiv:1301.7062 and arXiv:1312.0621. We first derive the duals to three conti...

  9. The theory of Langmuir probes in strong electrostatic potential structures

    Science.gov (United States)

    Borovsky, J. E.

    1986-01-01

    The operation of collecting and emitting Langmuir probes and double probes within time-stationary strong electrostatic potential structures is analyzed. The cross sections of spherical and cylindrical probes to charged particles within the structures are presented and used to obtain the current-voltage characteristics of idealized probes. The acquisition of plasma parameters from these characteristics is outlined, and the operation of idealized floating double-probe systems is analyzed. Probe surface effects are added to the idealized theory, and some surface effects pertinent to spacecraft probes are quantified. Magnetic field effects on idealized probes are examined, and the time required for floating probes to change their potentials by collecting charge and by emitting photoelectrons is discussed. Calculations on the space-charge effects of probe-perturbed beams and on the space-charge limiting of electron emission are given in an appendix.

  10. Venus within ESA probe reach

    Science.gov (United States)

    2006-03-01

    Venus Express mission controllers at the ESA Space Operations Centre (ESOC) in Darmstadt, Germany are making intensive preparations for orbit insertion. This comprises a series of telecommands, engine burns and manoeuvres designed to slow the spacecraft down from a velocity of 29000 km per hour relative to Venus, just before the first burn, to an entry velocity some 15% slower, allowing the probe to be captured into orbit around the planet. The spacecraft will have to ignite its main engine for 50 minutes in order to achieve deceleration and place itself into a highly elliptical orbit around the planet. Most of its 570 kg of onboard propellant will be used for this manoeuvre. The spacecraft’s solar arrays will be positioned so as to reduce the possibility of excessive mechanical load during engine ignition. Over the subsequent days, a series of additional burns will be done to lower the orbit apocentre and to control the pericentre. The aim is to end up in a 24-hour orbit around Venus early in May. The Venus orbit injection operations can be followed live at ESA establishments, with ESOC acting as focal point of interest (see attached programme). In all establishments, ESA specialists will be on hand for interviews. ESA TV will cover this event live from ESOC in Darmstadt. The live transmission will be carried free-to-air. For broadcasters, complete details of the various satellite feeds are listed at http://television.esa.int. The event will be covered on the web at venus.esa.int. The website will feature regular updates, including video coverage of the press conference and podcast from the control room at ESA’s Operations Centre. Media representatives wishing to follow the event at one of the ESA establishments listed below are requested to fill in the attached registration form and fax it back to the place of their choice. For further information, please contact: ESA Media Relations Division Tel : +33(0)1.53.69.7155 Fax: +33(0)1.53.69.7690 Venus Express

  11. Falsificationism and clinical trials.

    Science.gov (United States)

    Senn, S J

    1991-11-01

    The relevance of the philosophy of Sir Karl Popper to the planning, conduct and analysis of clinical trials is examined. It is shown that blinding and randomization can only be regarded as valuable for the purpose of refuting universal hypotheses. The purpose of inclusion criteria is also examined. It is concluded that a misplaced belief in induction is responsible for many false notions regarding clinical trials.

  12. VIDEO MODELING TO TRAIN STAFF TO IMPLEMENT DISCRETE-TRIAL INSTRUCTION

    Science.gov (United States)

    Catania, Cynthia N; Almeida, Daniel; Liu-Constant, Brian; DiGennaro Reed, Florence D

    2009-01-01

    Three new direct-service staff participated in a program that used a video model to train target skills needed to conduct a discrete-trial session. Percentage accuracy in completing a discrete-trial teaching session was evaluated using a multiple baseline design across participants. During baseline, performances ranged from a mean of 12% to 63% accuracy. During video modeling, there was an immediate increase in accuracy to a mean of 98%, 85%, and 94% for each participant. Performance during maintenance and generalization probes remained at high levels. Results suggest that video modeling can be an effective technique to train staff to conduct discrete-trial sessions. PMID:19949529

  13. VelProbePE: An automated spreadsheet program for interpreting point velocity probe breakthrough curves

    Science.gov (United States)

    Schillig, P. C.

    2012-02-01

    Groundwater velocity is an important parameter for determining the fate and transport of contaminants. Recently developed point velocity probes (PVPs) were designed to provide centimeter-scale measurements of the direction and magnitude of groundwater velocity based on the injection and electrical detection of a small, saline tracer. The code reported here for velocity probe parameter estimation (VelProbePE) was designed using Visual Basic for Applications (VBA) in Microsoft Excel for processing and interpreting tracer breakthrough curves specifically for PVP applications. VelProbePE contains multiple, autoinitializing user forms that guide the user through the data-processing steps. The program allows for the rapid processing and editing of up to 16 detector signals in a single workbook. VelProbePE uses simplex optimization to calculate the intermediate parameters required for the estimation of velocity magnitude and direction.

  14. Modeling Atom Probe Tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Vurpillot, F., E-mail: francois.vurpillot@univ-rouen.fr [Groupe de Physique des Matériaux, UMR CNRS 6634, Université de Rouen, Saint Etienne du Rouvray 76801 (France); Oberdorfer, C. [Institut für Materialwissenschaft, Lehrstuhl für Materialphysik, Universität Stuttgart, Heisenbergstr. 3, 70569 Stuttgart (Germany)

    2015-12-15

    Improving both the precision and the accuracy of Atom Probe Tomography reconstruction requires a correct understanding of the imaging process. In this aim, numerical modeling approaches have been developed for 15 years. The injected ingredients of these modeling tools are related to the basic physic of the field evaporation mechanism. The interplay between the sample nature and structure of the analyzed sample and the reconstructed image artefacts have pushed to gradually improve and make the model more and more sophisticated. This paper reviews the evolution of the modeling approach in Atom Probe Tomography and presents some future potential directions in order to improve the method. - Highlights: • The basics of field evaporation. • The main aspects of Atom Probe Tomography modeling. • The intrinsic limitations of the current method and future potential directions to improve the understanding of tip to image ion projection.

  15. Characterization of qubit chains by Feynman probes

    Science.gov (United States)

    Tamascelli, Dario; Benedetti, Claudia; Olivares, Stefano; Paris, Matteo G. A.

    2016-10-01

    We address the characterization of qubit chains and assess the performances of local measurements compared to those provided by Feynman probes, i.e., nonlocal measurements realized by coupling a single-qubit register to the chain. We show that local measurements are suitable to estimate small values of the coupling and that a Bayesian strategy may be successfully exploited to achieve optimal precision. For larger values of the coupling Bayesian local strategies do not lead to a consistent estimate. In this regime, Feynman probes may be exploited to build a consistent Bayesian estimator that saturates the Cramér-Rao bound, thus providing an effective characterization of the chain. Finally, we show that ultimate bounds to precision, i.e., saturation of the quantum Cramér-Rao bound, may be achieved by a two-step scheme employing Feynman probes followed by local measurements.

  16. Gravity and On-Shell Probe Actions

    CERN Document Server

    Ferrari, Frank

    2016-01-01

    In any gravitational theory and in a wide class of background space-times, we argue that there exists a simple, yet profound, relation between the on-shell Euclidean gravitational action and the on-shell Euclidean action of probes. The probes can be, for instance, charged particles or branes. The relation is tightly related to the thermodynamic nature of gravity. We provide precise checks of the relation in several examples, which include both asymptotically flat and asymptotically AdS space-times, with particle, D-brane and M-brane probes. Perfect consistency is found in all cases, including in a highly non-trivial example including \\alpha'-corrections.

  17. Universal microbial diagnostics using random DNA probes

    Science.gov (United States)

    Aghazadeh, Amirali; Lin, Adam Y.; Sheikh, Mona A.; Chen, Allen L.; Atkins, Lisa M.; Johnson, Coreen L.; Petrosino, Joseph F.; Drezek, Rebekah A.; Baraniuk, Richard G.

    2016-01-01

    Early identification of pathogens is essential for limiting development of therapy-resistant pathogens and mitigating infectious disease outbreaks. Most bacterial detection schemes use target-specific probes to differentiate pathogen species, creating time and cost inefficiencies in identifying newly discovered organisms. We present a novel universal microbial diagnostics (UMD) platform to screen for microbial organisms in an infectious sample, using a small number of random DNA probes that are agnostic to the target DNA sequences. Our platform leverages the theory of sparse signal recovery (compressive sensing) to identify the composition of a microbial sample that potentially contains novel or mutant species. We validated the UMD platform in vitro using five random probes to recover 11 pathogenic bacteria. We further demonstrated in silico that UMD can be generalized to screen for common human pathogens in different taxonomy levels. UMD’s unorthodox sensing approach opens the door to more efficient and universal molecular diagnostics. PMID:27704040

  18. Gravity and on-shell probe actions

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Frank [Université libre de Bruxelles (ULB) and International Solvay Institutes,Service de Physique Théorique et Mathématique,Campus de la Plaine, CP 231, B-1050 Bruxelles (Belgium); Theoretical Physics Department, CERN,CH-1211 Genève (Switzerland); Rovai, Antonin [Département de Physique Théorique, Université de Genève,24, quai Ansermet, CH-1211 Genève 4 (Switzerland); Université libre de Bruxelles (ULB) and International Solvay Institutes,Service de Physique Théorique et Mathématique,Campus de la Plaine, CP 231, B-1050 Bruxelles (Belgium); Center for Theoretical Physics, Massachusetts Institute of Technology,77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Arnold Sommerfeld Center for Theoretical Physics, Ludwig-Maximilians-Universität München,Theresienstrasse 37, D-80333 München (Germany)

    2016-08-08

    In any gravitational theory and in a wide class of background space-times, we argue that there exists a simple, yet profound, relation between the on-shell Euclidean gravitational action and the on-shell Euclidean action of probes. The probes can be, for instance, charged particles or branes. The relation is tightly related to the thermodynamic nature of gravity. We provide precise checks of the relation in several examples, which include both asymptotically flat and asymptotically AdS space-times, with particle, D-brane and M-brane probes. Perfect consistency is found in all cases, including in a highly non-trivial example including α{sup ′}-corrections.

  19. Holographic Phase Transition Probed by Nonlocal Observables

    Directory of Open Access Journals (Sweden)

    Xiao-Xiong Zeng

    2016-01-01

    Full Text Available From the viewpoint of holography, the phase structure of a 5-dimensional Reissner-Nordström-AdS black hole is probed by the two-point correlation function, Wilson loop, and entanglement entropy. As the case of thermal entropy, we find for all the probes that the black hole undergoes a Hawking-Page phase transition, a first-order phase transition, and a second-order phase transition successively before it reaches a stable phase. In addition, for these probes, we find that the equal area law for the first-order phase transition is valid always and the critical exponent of the heat capacity for the second-order phase transition coincides with that of the mean field theory regardless of the size of the boundary region.

  20. Isotropic Broadband E-Field Probe

    Directory of Open Access Journals (Sweden)

    Béla Szentpáli

    2008-01-01

    Full Text Available An E-field probe has been developed for EMC immunity tests performed in closed space. The leads are flexible resistive transmission lines. Their influence on the field distribution is negligible. The probe has an isotropic reception from 100 MHz to 18 GHz; the sensitivity is in the 3 V/m–10 V/m range. The device is an accessory of the EMC test chamber. The readout of the field magnitude is carried out by personal computer, which fulfils also the required corrections of the raw data.

  1. Collective electronic effects in scanning probe microscopy

    Science.gov (United States)

    Passian, Ali

    The surface plasmon dispersion relations are calculated for a metal coated dielectric probe above a dielectric half space with and without metal coating. Employing prolate spheroidal coordinate system this configuration was modeled as confocal single-sheeted hyperboloids of revolution superimposed on planar domains. The involved media are characterized by frequency dependent, spatially local dielectric functions. Due to subwavelength dimensions of the region of interest, nonretarded electrodynamics is utilized to derive exact analytical expressions describing the resonant surface modes. The dispersion relations are studied as functions of the parameter that defines the hyperboloidal boundaries of the tip and the corresponding coating, and as functions of the involved coating thicknesses. Both parallel and perpendicular polarizations are considered. The results are simulated numerically and limiting cases are discussed with comparison to the Cartesian thin foil case. Using this new type of probe-substrate configuration, the surface plasmon coupling mechanism is investigated experimentally utilizing a scanning probe microscope, and the signal strength acquired by the probe is measured as a function of the distance between the probe and the sample. This is repeated at three different wavelengths of the incident p-polarized photons used to stimulate surface plasmons in the thin metal foil. The results are compared with the theory. Utilizing the prolate spheroidal coordinate system, the related and relevant problem of the Coulomb interaction of a dielectric probe tip with a uniform field existing above a semiinfinite, homogeneous dielectric substrate was studied. This is of interest in atomic force microscopy when the sample surface is electrically charged. The induced polarization surface charge density and the field distribution at the bounding surface of the dielectric medium with the geometry of a single-sheeted hyperboloid of revolution located above the dielectric

  2. Nanobits - exchangable and customisable scanning probe tips

    DEFF Research Database (Denmark)

    Yildiz, Izzet

    Invention of atomic force microscopy (AFM) pioneered a novel aspect for the surface metrology concept. A range of scanning probe methods have been developed over the years based on different sorts of tip-surface interaction: electrical, optical, thermal, force. Reproducible and fast fabrication......Bits were investigated by imaging optical gratings. In most cases, the NanoBits showed better performance than the standard pyramid AFM probes, and long scan experiments proved that (i) the NanoBits did not get blunt even after 100 scans (continuous 30 h imaging), and (ii) stiction into the slit...

  3. The future of atom probe tomography

    Directory of Open Access Journals (Sweden)

    Michael K. Miller

    2012-04-01

    Full Text Available The dream of the microscopy and materials science communities is to see, identify, accurately locate, and determine the fundamental physical properties of every atom in a specimen. With this knowledge together with modern computer models and simulations, a full understanding of the properties of a material can be determined. This fundamental knowledge leads to the design and development of more advanced materials for solving the needs of society. The technique of atom probe tomography is the closest to fulfilling this dream but is still significantly short of the goal. The future of atom probe tomography, and the prospects for achieving this ultimate goal are outlined.

  4. Atmospheric trident production for probing new physics

    Directory of Open Access Journals (Sweden)

    Shao-Feng Ge

    2017-09-01

    Full Text Available We propose to use atmospheric neutrinos as a powerful probe of new physics beyond the Standard Model via neutrino trident production. The final state with double muon tracks simultaneously produced from the same vertex is a distinctive signal at large Cherenkov detectors. We calculate the expected event numbers of trident production in the Standard Model. To illustrate the potential of this process to probe new physics we obtain the sensitivity on new vector/scalar bosons with coupling to muon and tau neutrinos.

  5. DESIGN OF THE CONTACT POTENTIALS DIFFERENCE PROBES

    Directory of Open Access Journals (Sweden)

    K. U. Pantsialeyeu

    2016-01-01

    Full Text Available The contact potential difference probes distinguished by great variety and produced mostly in the laboratory for specific experimental applications. As a rule, they consist of commercially available instrumentation, and have a number of disadvantages: large dimensions, complexity and high cost, small sensitivity, operating speed, noiseproof, etc. The purpose of this paper is to describe the basic approaches to design of the small dimension, complete contact potential difference probes, providing high sensitivity, operating speed, and noise immunity. In this paper the contact potential difference probe, which is a electrometer with dynamic capacitor plate at about 0.1–5 mm2 . These probes are could be used in scanning systems, such as a Scanning Kelvin Probe, as well as for controlling system of manufacturing processes, e.g. under friction. The design of such contact potential difference probes conducted using modern electronic components, unique circuitry and design solutions described in detail at paper. The electromechanical modulator applied for mechanical vibrations of the reference sample. To provide a high amplitude and phase stability the upgraded generator with Wien bridge was used instead traditional oscillation sensor. The preamplifier made on the base of modern operational amplifiers with femtoampere current input. The power of the preamplifier designed with «floating ground». It allows keeping the relation constant potential to the probe components when changing over a wide range the compensation voltage. The phase detector-integrator based on the electronic antiphase switches with the modulation frequency of the contact potential difference and the integrator. Fullwave phase detection would greatly increase the sensitivity of the probe. In addition, the application of the phase detection allows suppressing noise and crosstalk at frequencies different from the modulation frequency. The preamplifier and the reference sample

  6. Graphene MEMS: AFM probe performance improvement.

    Science.gov (United States)

    Martin-Olmos, Cristina; Rasool, Haider Imad; Weiller, Bruce H; Gimzewski, James K

    2013-05-28

    We explore the feasibility of growing a continuous layer of graphene in prepatterned substrates, like an engineered silicon wafer, and we apply this as a mold for the fabrication of AFM probes. This fabrication method proves the fabrication of SU-8 devices coated with graphene in a full-wafer parallel technology and with high yield. It also demonstrates that graphene coating enhances the functionality of SU-8 probes, turning them conductive and more resistant to wear. Furthermore, it opens new experimental possibilities such as studying graphene-graphene interaction at the nanoscale with the precision of an AFM or the exploration of properties in nonplanar graphene layers.

  7. Aggregate Formed by a Cationic Fluorescence Probe

    Institute of Scientific and Technical Information of China (English)

    TIAN, Juan; SANG, Da-Yong; JI, Guo-Zhen

    2007-01-01

    The aggregation behavior of a cationic fluorescence probe 10-(4,7,10,13,16-pentaoxa-1-azacyclooctadecyl-methyl)anthracen-9-ylmethyl dodecanoate (1) was observed and studied by a fluorescence methodology in acidic and neutral conditions. By using the Py scale, differences between simple aggregates and micelles have been discussed. The stability of simple aggregates was discussed in terms of hydrophobic interaction and electrostatic repulsion. The absence of excimer emission of the anthrancene moiety of probe 1 in neutral condition was attributed to the photoinduced electron transfer mechanism instead of photodimerization.

  8. Probe Measures Fouling As In Heat Exchangers

    Science.gov (United States)

    Marner, Wilbur J.; Macdavid, Kenton S.

    1990-01-01

    Combustion deposits reduce transfer of heat. Instrument measures fouling like that on gas side of heat exchanger in direct-fired boiler or heat-recovery system. Heat-flux probe includes tube with embedded meter in outer shell. Combustion gases flow over probe, and fouling accumulates on it, just as fouling would on heat exchanger. Embedded heat-flow meter is sandwich structure in which thin Chromel layers and middle alloy form thermopile. Users determine when fouling approaches unacceptable levels so they schedule cleaning and avoid decreased transfer of heat and increased drop in pressure fouling causes. Avoids cost of premature, unnecessary maintenance.

  9. Conductivity bounds in probe brane models

    CERN Document Server

    Ikeda, Tatsuhiko N; Nakai, Yuichiro

    2016-01-01

    We discuss upper and lower bounds on the electrical conductivity of finite temperature strongly coupled quantum field theories, holographically dual to probe brane models, within linear response. In a probe limit where disorder is introduced entirely through an inhomogeneous background charge density, we find simple lower and upper bounds on the electrical conductivity in arbitrary dimensions. In field theories in two spatial dimensions, we show that both bounds persist even when disorder is included in the bulk metric. We discuss the challenges with finding sharp lower bounds on conductivity in three or more spatial dimensions when the metric is inhomogeneous.

  10. SNe Ia as a cosmological probe

    CERN Document Server

    Meng, Xiangcun; Han, Zhanwen

    2015-01-01

    Type Ia supernovae luminosities can be corrected to render them useful as standard candles able to probe the expansion history of the universe. This technique was successful applied to discover the present acceleration of the universe. As the number of SNe Ia observed at high redshift increases and analysis techniques are perfected, people aim to use this technique to probe the equation of state of the dark energy. Nevertheless, the nature of SNe Ia progenitors remains controversial and concerns persist about possible evolution effects that may be larger and harder to characterize than the more obvious statistical uncertainties.

  11. Multipartite entanglement detection with nonsymmetric probing

    DEFF Research Database (Denmark)

    Dellantonio, Luca; Das, Sumanta; Appel, Jürgen

    2017-01-01

    We show that spin-squeezing criteria commonly used for entanglement detection can be erroneous if the probe is not symmetric. We then derive a lower bound on squeezing for separable states in spin systems probed asymmetrically. Using this we further develop a procedure that allows us to verify...... the degree of entanglement of a quantum state in the spin system. Finally, we apply our method for entanglement verification to existing experimental data, and use it to prove the existence of tripartite entanglement in a spin-squeezed atomic ensemble....

  12. Ethics and clinical trials.

    Science.gov (United States)

    Chassany, O; Duracinský, M

    1999-01-01

    The current reference guideline about ethics in clinical trials is the Declaration of Helsinki of human rights in medical research. Three major principles are emphasised: respect of the patient to accept or not to participate in a trial, the constraints and the presumed risks must be acceptable for patients included in a study, and vulnerable subjects should not participate in studies. The investigator is responsible for obtaining a free and well-informed consent from patients before their inclusion in a study. Where possible, a new drug should always first be compared to placebo in order to prove its superiority. Else, a small-sized trial comparing a new drug versus a reference treatment can lead to an erroneous conclusion of absence of difference. Moreover, good results or improvement are obtained in at least 30% of cases with placebo, whatever the disease. The use of placebo is unethical in life-threatening diseases and when an effective proved drug exists. The use of placebo is ethical in severe diseases with no efficient drug, in some severe diseases even when an active reference treatment is available, and in all moderate and functional diseases. In order to detect flawed studies, most journals now ask for any manuscript submitted and reporting results of a randomised clinical trial to join a checklist in order to verify the quality of the trial. Finally, it remains the responsibility of the doctor to decide whether or not a protocol is ethical, to participate or not and to include patients or not.

  13. Method for determining a spring constant for a deformable scanning probe microscope element, and scanning probe microscope and calibration device arranged for determining a spring constant for a probe element

    NARCIS (Netherlands)

    Sadeghian, H.; Yang, C.K.; Bossche, A.; French, P.J.; Goosen, J.F.L.; Van Keulen, A.

    2012-01-01

    A method for determining a spring constant k for a deformable probe element (102) of a scanning probe microscope SPM (100). The probe (102) has an outer surface area consisting of a tip area (112) on a first probe side (108) and a tip-less area (113). The probe (102) also has a probe electrode (114)

  14. Phoenix Conductivity Probe Inserted in Martian Soil

    Science.gov (United States)

    2008-01-01

    This series of six images from the Robotic Arm Camera on NASA's Phoenix Mars Lander records the first time that the four spikes of the lander's thermal and electrical conductivity probe were inserted into Martian soil. The images were taken on July 8, 2008, during the Phoenix mission's 43rd Martian day, or sol, since landing. The insertion visible from the shadows cast on the ground on that sol was a validation test of the procedure. The spikes on the probe are about 1.5 centimeters or half an inch long. The science team will use the probe tool to assess how easily heat and electricity move through the soil from one spike to another. Such measurements can provide information about frozen or unfrozen water in the soil. The probe is mounted on the 'knuckle' of Phoenix's Robotic Arm. It has already been used for assessing water vapor in the atmosphere when it is held above the ground. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is led by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. Pulsars as Fantastic Objects and Probes

    CERN Document Server

    Han, J L

    2009-01-01

    Pulsars are fantastic objects, which show the extreme states of matters and plasma physics not understood yet. Pulsars can be used as probes for the detection of interstellar medium and even the gravitational waves. Here I review the basic facts of pulsars which should attract students to choose pulsar studies as their future projects.

  16. The probe rules in single particle tracking

    DEFF Research Database (Denmark)

    Clausen, Mathias P.; Lagerholm, B. Christoffer

    2011-01-01

    techniques it has been determined that the organization of native plasma membranes is heterogeneous over a very large range of spatial and temporal scales. The observed heterogeneities in the organization have the practical consequence that the SPT results in investigations of native plasma membranes....... The focus of this review is on the impact that the SPT probe has on the experimental results in SPT....

  17. Recombinant phage probes for Listeria monocytogenes

    Energy Technology Data Exchange (ETDEWEB)

    Carnazza, S; Gioffre, G; Felici, F; Guglielmino, S [Department of Microbiological, Genetic and Molecular Sciences, University of Messina, Messina (Italy)

    2007-10-03

    Monitoring of food and environmental samples for biological threats, such as Listeria monocytogenes, requires probes that specifically bind biological agents and ensure their immediate and efficient detection. There is a need for robust and inexpensive affinity probes as an alternative to antibodies. These probes may be recruited from random peptide libraries displayed on filamentous phage. In this study, we selected from two phage peptide libraries phage clones displaying peptides capable of specific and strong binding to the L. monocytogenes cell surface. The ability of isolated phage clones to interact specifically with L. monocytogenes was demonstrated using enzyme-linked immunosorbent assay (ELISA) and confirmed by co-precipitation assay. We also assessed the sensitivity of phage-bacteria binding by PCR on phage-captured Listeria cells, which could be detected at a concentration of 10{sup 4} cells ml{sup -1}. In addition, as proof-of-concept, we tested the possibility of immobilizing the affinity-selected phages to a putative biosensor surface. The quality of phage deposition was monitored by ELISA and fluorescent microscopy. Phage-bacterial binding was confirmed by high power optical phase contrast microscopy. Overall, the results of this work validate the concept of affinity-selected recombinant filamentous phages as probes for detecting and monitoring bacterial agents under any conditions that warrant their recognition, including in food products.

  18. Formative Assessment Probes: Representing Microscopic Life

    Science.gov (United States)

    Keeley, Page

    2011-01-01

    This column focuses on promoting learning through assessment. The author discusses the formative assessment probe "Pond Water," which reveals how elementary children will often apply what they know about animal structures to newly discovered microscopic organisms, connecting their knowledge of the familiar to the unfamiliar through…

  19. Luminescent probes for optical in vivo imaging

    Science.gov (United States)

    Texier, Isabelle; Josserand, Veronique; Garanger, Elisabeth; Razkin, Jesus; Jin, Zhaohui; Dumy, Pascal; Favrot, Marie; Boturyn, Didier; Coll, Jean-Luc

    2005-04-01

    Going along with instrumental development for small animal fluorescence in vivo imaging, we are developing molecular fluorescent probes, especially for tumor targeting. Several criteria have to be taken into account for the optimization of the luminescent label. It should be adapted to the in vivo imaging optical conditions : red-shifted absorption and emission, limited overlap between absorption and emission for a good signal filtering, optimized luminescence quantum yield, limited photo-bleaching. Moreover, the whole probe should fulfill the biological requirements for in vivo labeling : adapted blood-time circulation, biological conditions compatibility, low toxicity. We here demonstrate the ability of the imaging fluorescence set-up developed in LETI to image the bio-distribution of molecular probes on short times after injection. Targeting with Cy5 labeled holo-transferrin of subcutaneous TS/Apc (angiogenic murine breast carcinoma model) or IGROV1 (human ovarian cancer) tumors was achieved. Differences in the kinetics of the protein uptake by the tumors were evidenced. IGROV1 internal metastatic nodes implanted in the peritoneal cavity could be detected in nude mice. However, targeted metastatic nodes in lung cancer could only be imaged after dissection of the mouse. These results validate our fluorescence imaging set-up and the use of Cy5 as a luminescent label. New fluorescent probes based on this dye and a molecular delivery template (the RAFT molecule) can thus be envisioned.

  20. Gravity Probe B:. Launch and Initialization

    Science.gov (United States)

    Keiser, G. M.; Bencze, W. J.; Brumley, R. W.; Buchman, S.; Clarke, B.; Debra, D.; Everitt, C. W. F.; Green, G.; Heifetz, M. I.; Hipkins, D. N.; Holmes, T.; Li, J.; Mester, J.; Muhlfelder, B.; Murray, D.; Ohshima, Y.; Parkinson, B. W.; Salomon, M.; Santiago, D.; Shestople, P.; Silbergleit, A. S.; Solomonik, V.; Taber, M.; Turneaure, J. P.

    2005-04-01

    The scientific instrument and the major subsystems of the Gravity Probe B satellite are described. Following launch, the initial on-orbit operations were designed to check the operations of each of these major subsystems, provide an initial on-orbit calibration of the scientific instrument, set up the instrument in its operational mode, and spin up and align each of the four gyroscopes.

  1. Vertically aligned nanostructure scanning probe microscope tips

    Science.gov (United States)

    Guillorn, Michael A.; Ilic, Bojan; Melechko, Anatoli V.; Merkulov, Vladimir I.; Lowndes, Douglas H.; Simpson, Michael L.

    2006-12-19

    Methods and apparatus are described for cantilever structures that include a vertically aligned nanostructure, especially vertically aligned carbon nanofiber scanning probe microscope tips. An apparatus includes a cantilever structure including a substrate including a cantilever body, that optionally includes a doped layer, and a vertically aligned nanostructure coupled to the cantilever body.

  2. Flow cytometry, fluorescent probes, and flashing bacteria

    NARCIS (Netherlands)

    Bunthof, C.J.

    2002-01-01

     


    Key words: fluorescent probes, flow cytometry, CSLM, viability, survival, microbial physiology, lactic acid bacteria, Lactococcus lactis , Lactobacillus plantarum , cheese, milk, probiotic In food industry there is a perceived need for rapid methods for detection and viability a

  3. Raman spectroscopy system with hollow fiber probes

    Science.gov (United States)

    Liu, Bing-hong; Shi, Yi-Wei

    2012-11-01

    A Raman remote spectroscopy system was realized using flexible hollow optical fiber as laser emittion and signal collection probes. A silver-coated hollow fiber has low-loss property and flat transmission characteristics in the visible wavelength regions. Compared with conventional silica optical fiber, little background fluorescence noise was observed with optical fiber as the probe, which would be of great advantages to the detection in low frequency Raman shift region. The complex filtering and focusing system was thus unnecessary. The Raman spectra of CaCO3 and PE were obtained by using the system and a reasonable signal to noise ratio was attained without any lens. Experiments with probes made of conventional silica optical fibers were also conducted for comparisons. Furthermore, a silver-coated hollow glass waveguide was used as sample cell to detect liquid phase sample. We used a 6 cm-long hollow fiber as the liquid cell and Butt-couplings with emitting and collecting fibers. Experiment results show that the system obtained high signal to noise ratio because of the longer optical length between sample and laser light. We also give the elementary theoretical analysis for the hollow fiber sample cell. The parameters of the fiber which would affect the system were discussed. Hollow fiber has shown to be a potential fiber probe or sample cell for Raman spectroscopy.

  4. Uncertainty in Quantitative Electron Probe Microanalysis

    Science.gov (United States)

    Heinrich, Kurt F. J.

    2002-01-01

    Quantitative electron probe analysis is based on models based on the physics or x-ray generation, empirically adjusted to the analyses of specimens of known composition. Their accuracy can be estimated by applying them to a set of specimens of presumably well-known composition. PMID:27446746

  5. Cosmography with high-redshift probes

    Science.gov (United States)

    Vitagliano, Vincenzo

    2014-05-01

    I discuss how the cosmographic approach to the determination of cosmological parameters can be implemented with the inclusion of high-redshift data. I argue on the viability of such high-z probes for cosmographic purposes, and resume some statistical issues in finding the most reliable cosmographic truncation.

  6. Recombinant phage probes for Listeria monocytogenes

    Science.gov (United States)

    Carnazza, S.; Gioffrè, G.; Felici, F.; Guglielmino, S.

    2007-10-01

    Monitoring of food and environmental samples for biological threats, such as Listeria monocytogenes, requires probes that specifically bind biological agents and ensure their immediate and efficient detection. There is a need for robust and inexpensive affinity probes as an alternative to antibodies. These probes may be recruited from random peptide libraries displayed on filamentous phage. In this study, we selected from two phage peptide libraries phage clones displaying peptides capable of specific and strong binding to the L. monocytogenes cell surface. The ability of isolated phage clones to interact specifically with L. monocytogenes was demonstrated using enzyme-linked immunosorbent assay (ELISA) and confirmed by co-precipitation assay. We also assessed the sensitivity of phage-bacteria binding by PCR on phage-captured Listeria cells, which could be detected at a concentration of 104 cells ml-1. In addition, as proof-of-concept, we tested the possibility of immobilizing the affinity-selected phages to a putative biosensor surface. The quality of phage deposition was monitored by ELISA and fluorescent microscopy. Phage-bacterial binding was confirmed by high power optical phase contrast microscopy. Overall, the results of this work validate the concept of affinity-selected recombinant filamentous phages as probes for detecting and monitoring bacterial agents under any conditions that warrant their recognition, including in food products.

  7. University scientists test Mars probe equipment

    CERN Multimedia

    2002-01-01

    Scientists at Leicester University have spent four years researching and designing the Flight Model Position Adjustable Workbench (PAW) at the university. It will be attached to the Beagle 2 probe before being sent to the Red Planet in the spring (1/2 page).

  8. Piezoresistive Probe Array for High Throughput Applications

    NARCIS (Netherlands)

    Gaitas, A.; French, P.

    2011-01-01

    Microcantilevers are used in a number of applications including atomic-force microscopy (AFM). In this work, piezoresistive deflection-sensing elements are integrated onto micromachined cantilevers to increase sensitivity, and reduce complexity and cost. An array of probes with 5 nm gold ultrathin f

  9. Law and Society. CEM Probe, May 1977.

    Science.gov (United States)

    Bunker, Peter; Bunker, John

    The pamphlet is one issue of the PROBE series which gives British secondary school youth an overview of social issues and suggests questions for discussion. Information and issues about law and justice in England and Wales are discussed in this issue. Section one explains the differences between criminal law, which is enforced by the police, and…

  10. Transitions and probes in turbulent helium

    CERN Document Server

    Emsellem, V; Lohse, D; Tabeling, P; Wang, J

    1997-01-01

    Previous analysis of a Paris turbulence experiment \\cite{zoc94, tab95} shows a transition at the Taylor Reynolds number \\rel \\approx 700. Here correlation function data is analyzed which gives further evidence for this transition. It is seen in both the power spectrum and in structure function measurements. Two possible explanations may be offered for this observed transition: that it is intrinsic to the turbulence flow in this closed box experiment or that it is an effect of a change in the flow around the anemometer. We particularly examine a pair of ``probe effects''. The first is a thermal boundary layer which does exist about the probe and does limit the probe response, particularly at high frequencies. Arguments based on simulations of the response and upon observations of dissipation suggests that this effect is only crucial beyond \\rel\\approx 2000. The second effect is produced by vortex shedding behind the probe. This has been seen to produce a large modification in some of the power spectra for larg...

  11. Antibody Fragments as Probe in Biosensor Development

    Directory of Open Access Journals (Sweden)

    Serge Muyldermans

    2008-08-01

    Full Text Available Today’s proteomic analyses are generating increasing numbers of biomarkers, making it essential to possess highly specific probes able to recognize those targets. Antibodies are considered to be the first choice as molecular recognition units due to their target specificity and affinity, which make them excellent probes in biosensor development. However several problems such as difficult directional immobilization, unstable behavior, loss of specificity and steric hindrance, may arise from using these large molecules. Luckily, protein engineering techniques offer designed antibody formats suitable for biomarker analysis. Minimization strategies of antibodies into Fab fragments, scFv or even single-domain antibody fragments like VH, VL or VHHs are reviewed. Not only the size of the probe but also other issues like choice of immobilization tag, type of solid support and probe stability are of critical importance in assay development for biosensing. In this respect, multiple approaches to specifically orient and couple antibody fragments in a generic one-step procedure directly on a biosensor substrate are discussed.

  12. An airborne icing characterization probe: nephelometer prototype

    Science.gov (United States)

    Roques, S.

    2007-10-01

    The aeronautical industry uses airborne probes to characterize icing conditions for flight certification purposes by counting and sizing cloud droplets. Existing probes have been developed for meteorologists in order to study cloud microphysics. They are used on specific aircraft, instrumented for this type of study, but are not adapted for an industrial flight test environment. The development by Airbus of a new probe giving a real time response for particle sizes between 10 and 500 µm, adapted to operational requirements, is in progress. An optical principle by coherent shadowgraphy with a low coherency point source is used for the application. The size of the droplets is measured from their shadows on a CCD. A pulsed laser coupled to a fast camera freezes the movement. Usually, image processing rejects out-of-focus objects. Here, particles far from the focal plane can be sized because of the large depth of field due to the point source. The technique used increases the depth of field and the sampled volume is enough to build a histogram even for low droplet concentrations. Image processing is done in real time and results are provided to the flight test engineer. All data and images are recorded in order to allow on-ground complementary analysis if necessary. A non-telescopic prototype has been tested in a wind tunnel and in flight. The definitive probe being retractable is designed to be easily installed through a dummy window. Retracted, it will allow the aircraft to fly at VMO (maximum operating limit speed).

  13. Probing ionospheric structure using LOFAR data

    NARCIS (Netherlands)

    Mevius, M.; Van Der Tol, S.; Pandey, V. N.

    2015-01-01

    To obtain high quality images with the Lofar low frequency radio telescope, accurate ionospheric characterization and calibration is essential. The large field of view of LOFAR (several 10s of square degrees) requires good knowledge of the spatial variation of the ionosphere. In this work to probe t

  14. Probe and method for DNA detection

    Science.gov (United States)

    Yeh, Hsin-Chih; Werner, James Henry; Sharma, Jaswinder Kumar; Martinez, Jennifer Suzanne

    2013-07-02

    A hybridization probe containing two linear strands of DNA lights up upon hybridization to a target DNA using silver nanoclusters that have been templated onto one of the DNA strands. Hybridization induces proximity between the nanoclusters on one strand and an overhang on the other strand, which results in enhanced fluorescence emission from the nanoclusters.

  15. Carbon nanotubes as in vivo bacterial probes

    Science.gov (United States)

    Bardhan, Neelkanth M.; Ghosh, Debadyuti; Belcher, Angela M.

    2014-09-01

    With the rise in antibiotic-resistant infections, non-invasive sensing of infectious diseases is increasingly important. Optical imaging, although safer and simpler, is less developed than other modalities such as radioimaging, due to low availability of target-specific molecular probes. Here we report carbon nanotubes (SWNTs) as bacterial probes for fluorescence imaging of pathogenic infections. We demonstrate that SWNTs functionalized using M13 bacteriophage (M13-SWNT) can distinguish between F‧-positive and F‧-negative bacterial strains. Moreover, through one-step modification, we attach an anti-bacterial antibody on M13-SWNT, making it easily tunable for sensing specific F‧-negative bacteria. We illustrate detection of Staphylococcus aureus intramuscular infections, with ~3.4 × enhancement in fluorescence intensity over background. SWNT imaging presents lower signal spread ~0.08 × and higher signal amplification ~1.4 × , compared with conventional dyes. We show the probe offers greater ~5.7 × enhancement in imaging of S. aureus infective endocarditis. These biologically functionalized, aqueous-dispersed, actively targeted, modularly tunable SWNT probes offer new avenues for exploration of deeply buried infections.

  16. A piezo-bar pressure probe

    Science.gov (United States)

    Friend, W. H.; Murphy, C. L.; Shanfield, I.

    1967-01-01

    Piezo-bar pressure type probe measures the impact velocity or pressure of a moving debris cloud. It measures pressures up to 200,000 psi and peak pressures may be recorded with a total pulse duration between 5 and 65 musec.

  17. The FOCUS trial

    DEFF Research Database (Denmark)

    Glenthøj, Louise B; Fagerlund, Birgitte; Randers, Lasse

    2015-01-01

    trial enrolling 126 patients meeting the standardised criteria of being at UHR for psychosis. Patients are recruited from psychiatric in- and outpatient facilities in the Copenhagen catchment area. Patients are randomised to one of the two treatment arms: cognitive remediation plus standard treatment...... functioning, psychosis-like symptoms, negative symptomatology, and depressive symptomatology as measured with the Personal and Social Performance Scale, Brief Psychiatric Rating Scale-Expanded Version, Scale for the Assessment of Negative Symptoms, and the Montgomery-Åsberg Depression Rating Scale. DISCUSSION......: This is the first trial to evaluate the effects of neurocognitive and social cognitive remediation in UHR patients. The FOCUS trial results will provide evidence on the effect of targeted and comprehensive cognitive rehabilitation on cognition, daily living, and symptomatology as well as long-term outcome...

  18. OARSI Clinical Trials Recommendations

    DEFF Research Database (Denmark)

    Kraus, V B; Blanco, F J; Englund, M

    2015-01-01

    The objective of this work was to describe requirements for inclusion of soluble biomarkers in osteoarthritis (OA) clinical trials and progress toward OA-related biomarker qualification. The Guidelines for Biomarkers Working Group, representing experts in the field of OA biomarker research from...... of reasons but in particular, to determine whether biomarkers are useful in identifying those individuals most likely to receive clinically important benefits from an intervention; and to determine whether biomarkers are useful for identifying individuals at earlier stages of OA in order to institute...... both academia and industry, convened to discuss issues related to soluble biomarkers and to make recommendations for their use in OA clinical trials based on current knowledge and anticipated benefits. This document summarizes current guidance on use of biomarkers in OA clinical trials...

  19. Probing cell mechanical properties with microfluidic devices

    Science.gov (United States)

    Rowat, Amy

    2012-02-01

    Exploiting flow on the micron-scale is emerging as a method to probe cell mechanical properties with 10-1000x advances in throughput over existing technologies. The mechanical properties of cells and the cell nucleus are implicated in a wide range of biological contexts: for example, the ability of white blood cells to deform is central to immune response; and malignant cells show decreased stiffness compared to benign cells. We recently developed a microfluidic device to probe cell and nucleus mechanical properties: cells are forced to deform through a narrow constrictions in response to an applied pressure; flowing cells through a series of constrictions enables us to probe the ability of hundreds of cells to deform and relax during flow. By tuning the constriction width so it is narrower than the width of the cell nucleus, we can specifically probe the effects of nuclear physical properties on whole cell deformability. We show that the nucleus is the rate-limiting step in cell passage: inducing a change in its shape to a multilobed structure results in cells that transit more quickly; increased levels of lamin A, a nuclear protein that is key for nuclear shape and mechanical stability, impairs the passage of cells through constrictions. We are currently developing a new class of microfluidic devices to simultaneously probe the deformability of hundreds of cell samples in parallel. Using the same soft lithography techniques, membranes are fabricated to have well-defined pore distribution, width, length, and tortuosity. We design the membranes to interface with a multiwell plate, enabling simultaneous measurement of hundreds of different samples. Given the wide spectrum of diseases where altered cell and nucleus mechanical properties are implicated, such a platform has great potential, for example, to screen cells based on their mechanical phenotype against a library of drugs.

  20. Langmuir probe analysis in electronegative plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Bredin, Jerome, E-mail: jerome.bredin@lpp.polytechnique.fr; Chabert, Pascal; Aanesland, Ane [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau (France)

    2014-12-15

    This paper compares two methods to analyze Langmuir probe data obtained in electronegative plasmas. The techniques are developed to allow investigations in plasmas, where the electronegativity α{sub 0} = n{sub –}/n{sub e} (the ratio between the negative ion and electron densities) varies strongly. The first technique uses an analytical model to express the Langmuir probe current-voltage (I-V) characteristic and its second derivative as a function of the electron and ion densities (n{sub e}, n{sub +}, n{sub –}), temperatures (T{sub e}, T{sub +}, T{sub –}), and masses (m{sub e}, m{sub +}, m{sub –}). The analytical curves are fitted to the experimental data by adjusting these variables and parameters. To reduce the number of fitted parameters, the ion masses are assumed constant within the source volume, and quasi-neutrality is assumed everywhere. In this theory, Maxwellian distributions are assumed for all charged species. We show that this data analysis can predict the various plasma parameters within 5–10%, including the ion temperatures when α{sub 0} > 100. However, the method is tedious, time consuming, and requires a precise measurement of the energy distribution function. A second technique is therefore developed for easier access to the electron and ion densities, but does not give access to the ion temperatures. Here, only the measured I-V characteristic is needed. The electron density, temperature, and ion saturation current for positive ions are determined by classical probe techniques. The electronegativity α{sub 0} and the ion densities are deduced via an iterative method since these variables are coupled via the modified Bohm velocity. For both techniques, a Child-Law sheath model for cylindrical probes has been developed and is presented to emphasize the importance of this model for small cylindrical Langmuir probes.

  1. A note on measurement of sound pressure with intensity probes

    DEFF Research Database (Denmark)

    Juhl, Peter; Jacobsen, Finn

    2004-01-01

    be improved under a variety of realistic sound field conditions by applying a different weighting of the two pressure signals from the probe. The improved intensity probe can measure the sound pressure more accurately at high frequencies than an ordinary sound intensity probe or an ordinary sound level meter......The effect of scattering and diffraction on measurement of sound pressure with "two-microphone" sound intensity probes is examined using an axisymmetric boundary element model of the probe. Whereas it has been shown a few years ago that the sound intensity estimated with a two-microphone probe...

  2. Data Communication PC/NaI-borehole probe (Hardware & Software)

    DEFF Research Database (Denmark)

    Madsen, Peter Buch

    Development of new hard- & software to a NaI borehole probe on a PC. Save data from the probe each 10'th sec, handle the data from the probe and make calculations every 10'th sec and show the results on the monitor.......Development of new hard- & software to a NaI borehole probe on a PC. Save data from the probe each 10'th sec, handle the data from the probe and make calculations every 10'th sec and show the results on the monitor....

  3. OARSI Clinical Trials Recommendations

    DEFF Research Database (Denmark)

    McAlindon, T. E.; Driban, J. B.; Henrotin, Y.;

    2015-01-01

    The goal of this document is to update the original OARSI recommendations specifically for the design, conduct, and reporting of clinical trials that target symptom or structure modification among individuals with knee osteoarthritis (OA). To develop recommendations for the design, conduct...... and index knee, describing interventions, patient-reported and physical performance measures, structural outcome measures, biochemical biomarkers, and reporting recommendations. In summary, the working group identified 25 recommendations that represent the current best practices regarding clinical trials...... that target symptom or structure modification among individuals with knee OA. These updated recommendations incorporate novel technologies (e.g., magnetic resonance imaging (MRI)) and strategies to address the heterogeneity of knee OA....

  4. Dynamics of serial position change in probe-recognition task

    Directory of Open Access Journals (Sweden)

    Fifić Mario

    2002-01-01

    Full Text Available Relationship between practice and serial position effects was investigated, in order to obtain more evidence for underlying short-term memory processes. The investigated relationship is termed the dynamics of serial position change. To address this issue, the present study investigated mean latency, errors, and performed Ex-Gaussian convolution analysis. In six-block trials the probe-recognition task was used in the so-called fast experimental procedure. The serial position effect was significant in all six blocks. Both primacy and recency effects were detected, with primacy located in the first two blocks, producing a non-linear serial position effect. Although the serial position function became linear from the third block on, the convolution analysis revealed a non-linear change of the normal distribution parameter, suggesting special status of the last two serial positions. Further, separation of convolution parameters for serial position and practice was observed, suggesting different underlying mechanisms. In order to account for these findings, a strategy shift mechanism is suggested, rather then a mechanism based on changing the manner of memory scanning. Its influence is primarily located at the very beginning of the experimental session. The pattern of results of errors regarding the dynamics of serial position change closely paralleled those on reaction times. Several models of short-term memory were evaluated in order to account for these findings.

  5. Semiconductor nanocrystal probes for biological applications and process for making and using such probes

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, Shimon; Bruchez, Marcel; Alivisatos, Paul A.

    2016-12-27

    A semiconductor nanocrystal compound and probe are described. The compound is capable of linking to one or more affinity molecules. The compound comprises (1) one or more semiconductor nanocrystals capable of, in response to exposure to a first energy, providing a second energy, and (2) one or more linking agents, having a first portion linked to the one or more semiconductor nanocrystals and a second portion capable of linking to one or more affinity molecules. One or more semiconductor nanocrystal compounds are linked to one or more affinity molecules to form a semiconductor nanocrystal probe capable of bonding with one or more detectable substances in a material being analyzed, and capable of, in response to exposure to a first energy, providing a second energy. Also described are processes for respectively: making the semiconductor nanocrystal compound; making the semiconductor nanocrystal probe; and treating materials with the probe.

  6. Semiconductor nanocrystal probes for biological applications and process for making and using such probes

    Science.gov (United States)

    Weiss, Shimon; Bruchez, Marcel; Alivisatos, Paul

    2012-10-16

    A semiconductor nanocrystal compound and probe are described. The compound is capable of linking to one or more affinity molecules. The compound comprises (1) one or more semiconductor nanocrystals capable of, in response to exposure to a first energy, providing a second energy, and (2) one or more linking agents, having a first portion linked to the one or more semiconductor nanocrystals and a second portion capable of linking to one or more affinity molecules. One or more semiconductor nanocrystal compounds are linked to one or more affinity molecules to form a semiconductor nanocrystal probe capable of bonding with one or more detectable substances in a material being analyzed, and capable of, in response to exposure to a first energy, providing a second energy. Also described are processes for respectively: making the semiconductor nanocrystal compound; making the semiconductor nanocrystal probe; and treating materials with the probe.

  7. Study of probe-sample distance for biomedical spectra measurement

    Directory of Open Access Journals (Sweden)

    Li Lei

    2011-11-01

    Full Text Available Abstract Background Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. Method In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. Results The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. Conclusions We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  8. Periodontal Probe Improves Exams, Alleviates Pain

    Science.gov (United States)

    2008-01-01

    Dentists, comedian Bill Cosby memorably mused, tell you not to pick your teeth with any sharp metal object. Then you sit in their chair, and the first thing they grab is an iron hook!" Conventional periodontal probing is indeed invasive, uncomfortable for the patient, and the results can vary greatly between dentists and even for repeated measurements by the same dentist. It is a necessary procedure, though, as periodontal disease is the most common dental disease, involving the loss of teeth by the gradual destruction of ligaments that hold teeth in their sockets in the jawbone. The disease usually results from an increased concentration of bacteria in the pocket, or sulcus, between the gums and teeth. These bacteria produce acids and other byproducts, which enlarge the sulcus by eroding the gums and the periodontal ligaments. The sulcus normally has a depth of 1 to 2 millimeters, but in patients with early stages of periodontal disease, it has a depth of 3 to 5 millimeters. By measuring the depth of the sulcus, periodontists can have a good assessment of the disease s progress. Presently, there are no reliable clinical indicators of periodontal disease activity, and the best available diagnostic aid, periodontal probing, can only measure what has already been lost. A method for detecting small increments of periodontal ligament breakdown would permit earlier diagnosis and intervention with less costly and time-consuming therapy, while overcoming the problems associated with conventional probing. The painful, conventional method for probing may be destined for the archives of dental history, thanks to the development of ultrasound probing technologies. The roots of ultrasound probes are in an ultrasound-based time-of-flight technique routinely used to measure material thickness and length in the Nondestructive Evaluation Sciences Laboratory at Langley Research Center. The primary applications of that technology have been for corrosion detection and bolt tension

  9. OARSI Clinical Trials Recommendations

    DEFF Research Database (Denmark)

    Emery, C. A.; Roos, Ewa M.; Verhagen, E.;

    2015-01-01

    The risk of post-traumatic osteoarthritis (PTOA) substantially increases following joint injury. Research efforts should focus on investigating the efficacy of preventative strategies in high quality randomized controlled trials (RCT). The objective of these OARSI RCT recommendations is to inform...

  10. Participating in Clinical Trials

    Medline Plus

    Full Text Available skip navigation Help Search home health topics A-Z Videos A-Z about us Customer Support NIH SeniorHealth Built with You in Mind Resize Text: A A A Change Contrast print sign up Share Home > Health topics A-Z > Participating in Clinical Trials: About ...

  11. Hepatitis C: Clinical Trials

    Science.gov (United States)

    ... will not know if you are taking the medicine or the placebo until the clinical trial is over. How do ... can already get by prescription ) or sugar pills ( placebos ) with the new medicine may last longer than Phases I and II ...

  12. Clinical Trial Basics

    Science.gov (United States)

    ... How Am I Protected? Mark Bowden / iStock Ethical guidelines The goal of clinical research is to develop knowledge that improves human ... data and decide whether the results have medical importance. Results from clinical trials are often published in peer-reviewed scientific ...

  13. Langmuir-Probe Measurements in Flowing-Afterglow Plasmas

    Science.gov (United States)

    Johnsen, R.; Shunko, E. V.; Gougousi, T.; Golde, M. F.

    1994-01-01

    The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.

  14. Brane probes, toric geometry, and closed string tachyons

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, Tapobrata. E-mail: tapo@ictp.trieste.it

    2003-01-13

    We study non-supersymmetric orbifold singularities from the point of view of D-brane probes. We present a description of the decay of such singularities from considerations of the toric geometry of the probe branes.

  15. Brane Probes, Toric Geometry, and Closed String Tachyons

    OpenAIRE

    Sarkar, Tapobrata

    2002-01-01

    We study non-supersymmetric orbifold singularities from the point of view of D-brane probes. We present a description of the decay of such singularities from considerations of the toric geometry of the probe branes.

  16. Clinical Research and Clinical Trials

    Science.gov (United States)

    ... NICHD Publications Data Sharing and Other Resources Research Clinical Trials & Clinical Research Skip sharing on social media links ... health care providers, and researchers. Find NICHD-Supported Clinical Trials Use this link to find a list of ...

  17. What Are Clinical Trial Phases?

    Medline Plus

    Full Text Available ... Trials Information A to Z List of Cancer Drugs Complementary & Alternative Medicine (CAM) Questions to Ask about ... Types of Treatment Side Effects Clinical Trials Cancer Drugs Complementary & Alternative Medicine Coping Feelings & Cancer Adjusting to ...

  18. What Are Clinical Trial Phases?

    Medline Plus

    Full Text Available ... Unusual Cancers of Childhood Treatment Childhood Cancer Genomics Study Findings Metastatic Cancer Metastatic Cancer Research Common Cancer ... Trials Insurance Coverage and Clinical Trials How to Work With Your Health Insurance Plan Federal Government Programs ...

  19. What Are Clinical Trial Phases?

    Medline Plus

    Full Text Available ... Trials Information A to Z List of Cancer Drugs Complementary & Alternative Medicine (CAM) Questions to Ask about ... Types of Treatment Side Effects Clinical Trials Cancer Drugs Complementary & Alternative Medicine Coping Feelings & Cancer Adjusting to ...

  20. Focused fluorescent probe library for metal cations and biological anions.

    Science.gov (United States)

    Rhee, Hyun-Woo; Lee, Sang Wook; Lee, Jun-Seok; Chang, Young-Tae; Hong, Jong-In

    2013-09-09

    A focused fluorescent probe library for metal cations was developed by combining metal chelators and picolinium/quinolinium moieties as combinatorial blocks connected through a styryl group. Furthermore, metal complexes derived from metal chelators having high binding affinities for metal cations were used to construct a focused probe library for phosphorylated biomolecules. More than 250 fluorescent probes were screened for identifying an ultraselective probe for dTTP.

  1. Hydraulic design of geothermal probes; Hydraulische Auslegung von Erdwaermesondenanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Rosinski, Christoph; Zapp, Franz Josef [GEFGA mbH, Gesellschaft zur Entwicklung und Foerderung von Geothermen Anlagen, Limburg (Germany)

    2011-07-01

    Based on hydraulic considerations of geothermal probes of various designs and dimensions, the contribution under consideration reports on various influences on the heat transfer capacity of geothermal probes. The influence of laminar and turbulent pipe flow on the heat transfer capacity of geothermal probes is explained. Various parameters are considered such as the effect of various antifreezing compounds and the different types of construction of geothermal probes.

  2. Investigations of Probe Induced Perturbations in a Hall Thruster

    Energy Technology Data Exchange (ETDEWEB)

    D. Staack; Y. Raitses; N.J. Fisch

    2002-08-12

    An electrostatic probe used to measure spatial plasma parameters in a Hall thruster generates perturbations of the plasma. These perturbations are examined by varying the probe material, penetration distance, residence time, and the nominal thruster conditions. The study leads us to recommendations for probe design and thruster operating conditions to reduce discharge perturbations, including metal shielding of the probe insulator and operation of the thruster at lower densities.

  3. Test probe for surface mounted leadless chip carrier

    Science.gov (United States)

    Meyer, Kerry L.; Topolewski, John

    1989-05-23

    A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.

  4. Scanning probe microscopy at video-rate

    Directory of Open Access Journals (Sweden)

    Georg Schitter

    2008-01-01

    Full Text Available Recent results have demonstrated the feasibility of video-rate scanning tunneling microscopy and video-rate atomic force microscopy. The further development of this technology will enable the direct observation of many dynamic processes that are impossible to observe today with conventional Scanning Probe Microscopes (SPMs. Examples are atom and molecule diffusion processes, the motion of molecular motors, real-time film growth, and chemical or catalytic reactions. Video-rate scanning probe technology might also lead to the extended application of SPMs in industry, e.g. for process control. In this paper we discuss the critical aspects that have to be taken into account for improving the imaging speed of SPMs. We point out the required instrumentation efforts, give an overview of the state of the art in high-speed scanning technology and discuss the required future developments for imaging at video-rates.

  5. A probe station for testing silicon sensors

    CERN Multimedia

    Caraban Gonzalez, Noemi

    2017-01-01

    A probe station for testing silicon sensors. The probe station is located inside a dark box that can keep away light during the measurement. The set-up is located in the DSF (Department Silicon Facility). The golden plate is the "chuck" where the sensor is usually placed on. With the help of "manipulators", thin needles can be precisely positioned that can contact the sensor surface. Using these needles and the golden chuck, a high voltage can be applied to the sensor to test its behaviour under high voltage. We will use the silicon sensors that we test here for building prototypes of a highly granular sandwich calorimeter, the CMS HGC (Highly granular Calorimeter) upgrade for High-Luminosity LHC.

  6. Probing complex RNA structures by mechanical force

    CERN Document Server

    Harlepp, S; Robert, J; Leger, J F; Xayaphoummine, A; Isambert, H; Chatenay, D

    2003-01-01

    RNA secondary structures of increasing complexity are probed combining single molecule stretching experiments and stochastic unfolding/refolding simulations. We find that force-induced unfolding pathways cannot usually be interpretated by solely invoking successive openings of native helices. Indeed, typical force-extension responses of complex RNA molecules are largely shaped by stretching-induced, long-lived intermediates including non-native helices. This is first shown for a set of generic structural motifs found in larger RNA structures, and then for Escherichia coli's 1540-base long 16S ribosomal RNA, which exhibits a surprisingly well-structured and reproducible unfolding pathway under mechanical stretching. Using out-of-equilibrium stochastic simulations, we demonstrate that these experimental results reflect the slow relaxation of RNA structural rearrangements. Hence, micromanipulations of single RNA molecules probe both their native structures and long-lived intermediates, so-called "kinetic traps",...

  7. Quasars as probes of cosmological reionization

    CERN Document Server

    Mortlock, Daniel J

    2015-01-01

    Quasars are the most luminous non-transient sources in the epoch of cosmological reionization (i.e., which ended a billion years after the Big Bang, corresponding to a redshift of z ~ 5), and are powerful probes of the inter-galactic medium at that time. This review covers current efforts to identify high-redshift quasars and how they have been used to constrain the reionization history. This includes a full description of the various processes by which neutral hydrogen atoms can absorb/scatter ultraviolet photons, and which lead to the Gunn-Peterson effect, dark gap and dark pixel analyses, quasar near zones and damping wing absorption. Finally, the future prospects for using quasars as probes of reionization are described.

  8. Magnetically modulated fluorescent probes in turbid media

    CERN Document Server

    Yang,; Chen, Hongyu; Anker, Jeffrey N

    2010-01-01

    Magnetically modulated optical nanoprobes (MagMOONs) were used to detect and distinguish probe fluorescence from autofluorescent backgrounds in turbid media. MagMOONs are micro/nano-sized particles with magnetically controlled orientation and orientation-dependent fluorescence. These probes blink when they rotate in response to rotating external magnetic fields. This blinking signal can be separated from backgrounds enabling spectrochemical sensing in media with strong autofluorescence. We explore the effect of scattering on MagMOON fluorescence. Turbid media reduce the modulated MagMOON signal due to a combination of attenuation of fluorescence signal and reduction in contrast between "On" and "Off" states. The blinking MagMOON fluorescence spectrum can be detected in turbid non-dairy creamer solution with extinction 2.0, and through 9 mm of chicken breast tissue, suggesting that whole mouse imaging is feasible by using this strategy.

  9. Probing inflation models with gravitational waves

    CERN Document Server

    Domcke, Valerie

    2016-01-01

    A direct detection of primordial gravitational waves is the ultimate probe for any inflation model. While current CMB bounds predict the generic scale-invariant gravitational wave spectrum from slow-roll inflation to be below the reach of upcoming gravitational wave interferometers, this prospect may dramatically change if the inflaton is a pseudoscalar. In this case, a coupling to any abelian gauge field leads to a tachyonic instability for the latter and hence to a new source of gravitational waves, directly related to the dynamics of inflation. In this contribution we discuss how this setup enables the upcoming gravitational wave interferometers advanced LIGO/VIRGO and eLISA to probe the microphysics of inflation, distinguishing between different universality classes of single-field slow-roll inflation models. We find that the prime candidate for an early detection is a Starobinsky-like model.

  10. Novel Probes of Gravity and Dark Energy

    CERN Document Server

    Jain, Bhuvnesh; Thompson, Rodger; Upadhye, Amol; Battat, James; Brax, Philippe; Davis, Anne-Christine; de Rham, Claudia; Dodelson, Scott; Erickcek, Adrienne; Gabadadze, Gregory; Hu, Wayne; Hui, Lam; Huterer, Dragan; Kamionkowski, Marc; Khoury, Justin; Koyama, Kazuya; Li, Baojui; Linder, Eric; Schmidt, Fabian; Scoccimarro, Roman; Starkman, Glenn; Stubbs, Chris; Takada, Masahiro; Tolley, Andrew; Trodden, Mark; Uzan, Jean-Philippe; Vikram, Vinu; Weltman, Amanda; Wyman, Mark; Zaritsky, Dennis; Zhao, Gongbo

    2013-01-01

    The discovery of cosmic acceleration has stimulated theorists to consider dark energy or modifications to Einstein's General Relativity as possible explanations. The last decade has seen advances in theories that go beyond smooth dark energy -- modified gravity and interactions of dark energy. While the theoretical terrain is being actively explored, the generic presence of fifth forces and dark sector couplings suggests a set of distinct observational signatures. This report focuses on observations that differ from the conventional probes that map the expansion history or large-scale structure. Examples of such novel probes are: detection of scalar fields via lab experiments, tests of modified gravity using stars and galaxies in the nearby universe, comparison of lensing and dynamical masses of galaxies and clusters, and the measurements of fundamental constants at high redshift. The observational expertise involved is very broad as it spans laboratory experiments, high resolution astronomical imaging and sp...

  11. A probe station for testing silicon sensors

    CERN Multimedia

    Ulysse, Fichet

    2017-01-01

    A probe station for testing silicon sensors. The probe station is located inside a dark box that can keep away light during the measurement. The set-up is located in the DSF (Department Silicon Facility). The golden plate is the "chuck" where the sensor is usually placed on. With the help of "manipulators", thin needles can be precisely positioned that can contact the sensor surface. Using these needles and the golden chuck, a high voltage can be applied to the sensor to test its behaviour under high voltage. We will use the silicon sensors that we test here for building prototypes of a highly granular sandwich calorimeter, the CMS HGC (Highly granular Calorimeter) upgrade for High-Luminosity LHC.

  12. Probing Sagittarius A* accretion with ALMA

    Science.gov (United States)

    Murchikova, Elena

    2017-01-01

    The submm Hydrogen recombination line technique can be used as a probe of the Galactic Center. We present the results of our H30α observations of ionized gas from within 0.015 pc around SgrA*. The observations were obtained on ALMA in cycle 3. The line was not detected, but we were able to set a limit on the mass of the cool gas (T~ 104 K) at 2 × 10-3 M ⊙. This is the unique probe of gas cooler than T ~106 K traced by X-ray emission. The total amount of gas near SgrA* gives us clues to understanding the accretion rate of SgrA*.

  13. Solar Probe Cup - Demonstrated Laboratory Performance

    Science.gov (United States)

    Case, A. W.; Kasper, J. C.; Korreck, K. E.; Stevens, M. L.; Larson, D. E.; Wright, K. H., Jr.; Gallagher, D. L.; Whittlesey, P. L.

    2016-12-01

    The Solar Probe Cup (SPC) is a Faraday Cup instrument that will fly on the Solar Probe Plus (SPP) spacecraft, orbiting the Sun as close as 9.86 solar radii from the center of the Sun. The SPC instrument is designed to measure the thermal solar wind plasma (protons, alphas, and electrons) that will be encountered throughout its close encounter with the Sun. Due to the solar wind flow being primarily radial, the SPC instrument is pointed directly at the Sun, resulting in an extreme thermal environment that must be tolerated throughout the primary data collection phase. Laboratory testing has been performed over the past 6 months to demonstrate the instrument's performance relative to its requirements, and to characterize the measurements over the expected thermal range. This presentation will demonstrate the performance of the instrument as measured in the lab, describe the operational configurations planned for flight, and discuss the data products that will be created.

  14. Results from the Wilkinson Microwave Anisotropy Probe

    CERN Document Server

    Komatsu, Eiichiro

    2014-01-01

    The Wilkinson Microwave Anisotropy Probe (WMAP) mapped the distribution of temperature and polarization over the entire sky in five microwave frequency bands. These full-sky maps were used to obtain measurements of temperature and polarization anisotropy of the cosmic microwave background with the unprecedented accuracy and precision. The analysis of two-point correlation functions of temperature and polarization data gives determinations of the fundamental cosmological parameters such as the age and composition of the universe, as well as the key parameters describing the physics of inflation, which is further constrained by three-point correlation functions. WMAP observations alone reduced the flat $\\Lambda$ cold dark matter ($\\Lambda$CDM) cosmological model (six) parameter volume by a factor of >68,000 compared with pre-WMAP measurements. The WMAP observations (sometimes in combination with other astrophysical probes) convincingly show the existence of non-baryonic dark matter, the cosmic neutrino backgrou...

  15. Lectin-probed western blot analysis.

    Science.gov (United States)

    Sato, Takeshi

    2014-01-01

    Lectin-probed western blot analysis, the so-called lectin blot analysis, is a useful method to yield basic information on the glycan structures of glycoproteins, based on the carbohydrate-binding specificities of lectins. By lectin blot analysis, researchers can directly analyze the glycan structures without releasing the glycans from glycoproteins. Here, the author describes protocols for standard analysis, and applies analysis in combination with glycosidase digestion of blot.

  16. Probing the Higgs vacuum with general relativity

    Science.gov (United States)

    Mannheim, Philip D.; Kazanas, Demosthenes

    1991-01-01

    It is shown that the structure of the Higgs vacuum can be revealed in gravitational experiments which probe the Schwarzschild geometry to only one order in MG/r beyond that needed for the classical tests of general relativity. The possibility that deviations from the conventional geometry are at least theoretically conceivable is explored. The deviations obtained provide a diagnostic test for searching for the existence of macroscopic scalar fields and open up the possiblity for further exploring the Higgs mechanism.

  17. Toward atom probe tomography of microelectronic devices

    Science.gov (United States)

    Larson, D. J.; Lawrence, D.; Lefebvre, W.; Olson, D.; Prosa, T. J.; Reinhard, D. A.; Ulfig, R. M.; Clifton, P. H.; Bunton, J. H.; Lenz, D.; Olson, J. D.; Renaud, L.; Martin, I.; Kelly, T. F.

    2011-11-01

    Atom probe tomography and scanning transmission electron microscopy has been used to analyze a commercial microelectronics device prepared by depackaging and focused ion beam milling. Chemical and morphological data are presented from the source, drain and channel regions, and part of the gate oxide region of an Intel® i5-650 p-FET device demonstrating feasibility in using these techniques to investigate commercial chips.

  18. Scanning probe methods applied to molecular electronics

    OpenAIRE

    Pavliček, Niko

    2013-01-01

    Scanning probe methods on insulating films offer a rich toolbox to study electronic, structural and spin properties of individual molecules. This work discusses three issues in the field of molecular and organic electronics. A scanning tunneling microscopy (STM) head to be operated in high magnetic fields has been designed and built up. The STM head is very compact and rigid relying on a robust coarse approach mechanism. This will facilitate investigations of the spin properties of individ...

  19. Probing halo molecules with nonresonant light

    CERN Document Server

    Lemeshko, Mikhail

    2009-01-01

    We show that halo molecules can be probed by "shaking" in a pulsed nonresonant laser field. The field introduces a centrifugal term which expels the highest vibrational level from the potential that binds it. Our numerical simulations as well as an analytic model applied to the Rb$_2$ and KRb Feshbach molecules indicate that shaking by feasible laser pulses can be used to accurately recover the square of the vibrational wavefunction and, by inversion, also the molecular potential.

  20. Aligned ion implementation using scanning probes

    Energy Technology Data Exchange (ETDEWEB)

    Persaud, A.

    2006-12-12

    A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an ion beamline are presented. A placement resolution of about 120 nm is reported. The final placement accuracy is determined by the size of the aperture hole and by the straggle of the implanted ion inside the target material. The limits of this technology are expected to be set by the latter, which is of the order of 10 nm for low energy ions. This research has been carried out in the context of a larger program concerned with the development of quantum computer test structures. For that the placement accuracy needs to be increased and a detector for single ion detection has to be integrated into the setup. Both issues are discussed in this thesis. To achieve single ion detection highly charged ions are used for the implantation, as in addition to their kinetic energy they also deposit their potential energy in the target material, therefore making detection easier. A special ion source for producing these highly charged ions was used and their creation and interactions with solids of are discussed in detail. (orig.)

  1. Novel DNA probes for sensitive DNA detection

    OpenAIRE

    Richardson, James Alistair

    2010-01-01

    The ability to detect and interrogate DNA sequences allows further understanding and\\ud diagnosis of genetic disease. The ability to perform such analysis of genetic material\\ud requires highly selective and reliable technologies. Furthermore techniques which can use\\ud simple and cheap equipment allow the use of such technologies for point of care analysis.\\ud \\ud Described in this thesis are two novel DNA probe systems designed for mutation\\ud discrimination and sequence recognition of PCR ...

  2. Ultraspecific probes for high throughput HLA typing

    Directory of Open Access Journals (Sweden)

    Eggers Rick

    2009-02-01

    Full Text Available Abstract Background The variations within an individual's HLA (Human Leukocyte Antigen genes have been linked to many immunological events, e.g. susceptibility to disease, response to vaccines, and the success of blood, tissue, and organ transplants. Although the microarray format has the potential to achieve high-resolution typing, this has yet to be attained due to inefficiencies of current probe design strategies. Results We present a novel three-step approach for the design of high-throughput microarray assays for HLA typing. This approach first selects sequences containing the SNPs present in all alleles of the locus of interest and next calculates the number of base changes necessary to convert a candidate probe sequences to the closest subsequence within the set of sequences that are likely to be present in the sample including the remainder of the human genome in order to identify those candidate probes which are "ultraspecific" for the allele of interest. Due to the high specificity of these sequences, it is possible that preliminary steps such as PCR amplification are no longer necessary. Lastly, the minimum number of these ultraspecific probes is selected such that the highest resolution typing can be achieved for the minimal cost of production. As an example, an array was designed and in silico results were obtained for typing of the HLA-B locus. Conclusion The assay presented here provides a higher resolution than has previously been developed and includes more alleles than previously considered. Based upon the in silico and preliminary experimental results, we believe that the proposed approach can be readily applied to any highly polymorphic gene system.

  3. Probe into the interior of compact stars

    CERN Document Server

    Nana, Pan

    2007-01-01

    The interior of neutron stars contains nuclear matter at very high density for numerous subatomic particles compete with each other. Therefore, confirming the components and properties there is our significant task. Here we summarize the possible methods especial the way of r-mode instability to probe into the neutron star and show our some results. The KHz pulsar in XTE J1739-285 may give a significant implication

  4. Manipulating atoms using scanning probe microscopy

    OpenAIRE

    Norris, Andrew Christopher

    2009-01-01

    Manipulating species using Scanning Probe Microscopy (SPM) is an important discipline in the field of bottom-up fabrication, which facilitates nano-mechanics and electron dynamics investigations. Previous low temperature manipulation highlights include the construction of quantum dots, nano-wires and quantum corrals, all of which began in 1989 with Don Eigler’s iconic writing of I-B-M using 35 xenon atoms. Since then, the field has developed, and we now push, pull, hop, excite, desorb, rotate...

  5. Probing New Physics with Astrophysical Neutrinos

    OpenAIRE

    Bell, Nicole F.

    2008-01-01

    We review the prospects for probing new physics with neutrino astrophysics. High energy neutrinos provide an important means of accessing physics beyond the electroweak scale. Neutrinos have a number of advantages over conventional astronomy and, in particular, carry information encoded in their flavor degree of freedom which could reveal a variety of exotic neutrino properties. We also outline ways in which neutrino astrophysics can be used to constrain dark matter properties, and explain ho...

  6. Study of borehole probing methods to improve the ground characterization

    Science.gov (United States)

    Naeimipour, Ali

    Collecting geological information allows for optimizing ground control measures in underground structures. This includes understanding of the joints and discontinuities and rock strength to develop rock mass classifications. An ideal approach to collect such information is through correlating the drilling data from the roofbolters to assess rock strength and void location and properties. The current instrumented roofbolters are capable of providing some information on these properties but not fully developed for accurate ground characterization. To enhance existing systems additional instrumentation and testing was conducted in laboratory and field conditions. However, to define the geology along the boreholes, the use of probing was deemed to be most efficient approach for locating joints and structures in the ground and evaluation of rock strength. Therefore, this research focuses on selection and evaluation of proper borehole probes that can offer a reliable assessment of rock mass structure and rock strength. In particular, attention was paid to borehole televiewer to characterize rock mass structures and joints and development of mechanical rock scratcher for determination of rock strength. Rock bolt boreholes are commonly drilled in the ribs and the roof of underground environments. They are often small (about 1.5 inches) and short (mostly 2-3 meter). Most of them are oriented upward and thus, mostly dry or perhaps wet but not filled with water. No suitable system is available for probing in such conditions to identify the voids/joints and specifically to measure rock strength for evaluation of rock mass and related optimization of ground support design. A preliminary scan of available borehole probes proved that the best options for evaluation of rock structure is through analysis of borehole images, captured by optical televiewers. Laboratory and field trials with showed that these systems can be used to facilitate measurement of the location, frequency and

  7. Superiority of visual (verbal) vs. auditory test presentation modality in a P300-based CIT: The Complex Trial Protocol for concealed autobiographical memory detection.

    Science.gov (United States)

    Deng, Xiaohong; Rosenfeld, J Peter; Ward, Anne; Labkovsky, Elena

    2016-07-01

    This paper continues our efforts to determine which modality is best for presentation of stimuli in the P300-based concealed information test (CIT) called the Complex Trial Protocol (CTP). The first part of the CTP trial involves presentation of the key probe or irrelevant stimuli, and is followed by presentation of target (T) or non-target (NT). In Rosenfeld et al. (2015), probes and irrelevants regularly alternated modality over trials, but Ts and NTs were always visual. In the present study, (in both its experiments, EXP 1 and EXP 2), probes and irrelevants alternated modalities on successive trials, as before. In present EXP 1, Ts and NTs were always auditory, but in EXP 2, they were simultaneously auditory and visual. Probe P300 data were different in each study: In Rosenfeld et al. (2015) and EXP 2 here, the bootstrap-based detection rates based on probe-minus-irrelevant differences, significantly differed favoring visual probe and irrelevant presentation modality. In EXP 1 here, detection rates were the same for the two modalities. In Rosenfeld et al. (2015) there was no main effect of probe modality, visual vs. auditory on probe-minus-irrelevant P300 difference. There were such effects here in EXP 1 (ppresent pair of studies. RT was faster for visual stimuli in the present studies. The T and NT modality appears to interact with probe/irrelevant modality, and the best protocol for detecting concealed information is with the 2015 study protocol or that of EXP 2, using visual stimulus presentation.

  8. Modular design of AFM probe with sputtered silicon tip

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Thaysen, Jacob; Bouwstra, Siebe

    2001-01-01

    of the thin films constituting the cantilever. The AFM probe has an integrated tip made of a thick sputtered silicon layer, which is deposited after the probe has been defined and just before the cantilevers are released. The tips are so-called rocket tips made by reactive ion etching. We present probes...

  9. Wideband scalable probe for Spherical Near-Field Antenna measurements

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    The paper presents a design of an open-boundary quad-ridged horn to be used as a wideband scalable dual-linearly polarized probe for spherical near-field antenna measurements. With a new higher-order probe correction technique developed at the Technical University of Denmark, the probe will enabl...

  10. A coumarin-based colorimetric fluorescent probe for hydrogen sulfide

    Indian Academy of Sciences (India)

    Yanqiu Yang; Yu Liu; Liang Yang; Jun Liu; Kun Li; Shunzhong Luo

    2015-03-01

    A coumarin-based fluorescent probe for selective detection of hydrogen sulfide (H2S) is presented. This `off–on’ probe exhibited high selectivity towards H2S in aqueous solution with a detection limit of 30 nM. Notably, because of its dual nucleophilicity, the probe could avoid the interference of thiols and other sulfur containing compounds.

  11. Response of electrostatic probes to eccentric charge distributions

    DEFF Research Database (Denmark)

    Johansson, Torben; McAllister, Iain Wilson

    2001-01-01

    The response of an electrostatic probe mounted in an electrode is examined with reference to eccentric charge distributions. The study involves using the probe λ function to derive a characteristic parameter. This parameter enables the response of the probe to different degrees of eccentricity...

  12. The response of electrostatic probes via the λ-function

    DEFF Research Database (Denmark)

    Rerup, T.O.; Crichton, George C; McAllister, Iain Wilson

    1994-01-01

    The response of an electrostatic probe is examined with reference to a planar spacer. The study involves the numerical calculation of the probe λ-function, from which response-related characteristic parameters can be derived. These parameters enable the probe detection sensitivity and spatial...

  13. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  14. Band excitation method applicable to scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jesse, Stephen; Kalinin, Sergei V.

    2017-01-03

    Scanning probe microscopy may include a method for generating a band excitation (BE) signal and simultaneously exciting a probe at a plurality of frequencies within a predetermined frequency band based on the excitation signal. A response of the probe is measured across a subset of frequencies of the predetermined frequency band and the excitation signal is adjusted based on the measured response.

  15. Three-way flexible cantilever probes for static contact

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Jensen, Helle Vendelbo;

    2011-01-01

    In micro four-point probe measurements, three-way flexible L-shaped cantilever probes show significant advantages over conventional straight cantilever probes. The L-shaped cantilever allows static contact to the sample surface which reduces the frictional wear of the cantilever tips. We analyze...

  16. Diagnostic PCR: Comparative sensitivity of four probe chemistries

    DEFF Research Database (Denmark)

    Josefsen, Mathilde Hartmann; Löfström, Charlotta; Sommer, Helle Mølgaard

    2009-01-01

    Three probe chemistries: locked nucleic acid (LNA), minor groove binder (MGB) and Scorpion were compared with a TaqMan probe in a validated real-time PCR assay for detection of food-borne thermotolerant Campylobacter. The LNA probe produced significantly lower Ct-values and a higher proportion...

  17. Flow Cytometric Applicability of Fluorescent Vitality Probes on Phytoplankton

    NARCIS (Netherlands)

    Peperzak, L.; Brussaard, C.P.D.

    2011-01-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H(2)DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid) tri

  18. Improving comparability between microarray probe signals by thermodynamic intensity correction

    DEFF Research Database (Denmark)

    Bruun, G. M.; Wernersson, Rasmus; Juncker, Agnieszka

    2007-01-01

    different probes. It is therefore of great interest to correct for the variation between probes. Much of this variation is sequence dependent. We demonstrate that a thermodynamic model for hybridization of either DNA or RNA to a DNA microarray, which takes the sequence-dependent probe affinities...

  19. Probing New Physics with Isotope Shift Spectroscopy

    CERN Document Server

    Delaunay, Cédric

    2016-01-01

    We investigate the potential to probe physics beyond the Standard Model with isotope shift measurements of optical atomic clock transitions. We first derive the reach for generic new physics above the GeV scale at the effective field theory level, as well as estimate the limits on possible new spin-independent forces mediated by sub-GeV states coupled to electrons and neutrons. We also study the weak force and show that isotope shifts could provide strong constraints on the $Z^0$ couplings to valence quarks, which complement precision observables at LEP and atomic parity violation experiments. Finally, motivated by recent experimental hints of a new 750 GeV resonance in diphotons, we also consider the potential to probe its parity-preserving couplings to electrons, quarks and gluons with this method. In particular, combining the diphoton signal with indirect constraints from $g_e-2$ and isotope shifts in Ytterbium allows to probe the resonance coupling to electrons with unprecedented precision.

  20. A quantum spin-probe molecular microscope

    Science.gov (United States)

    Perunicic, V. S.; Hill, C. D.; Hall, L. T.; Hollenberg, L.C.L.

    2016-01-01

    Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic field gradient. Signals corresponding to specific regions of the molecule's nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51H79NO13) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy. PMID:27725630

  1. Bacteriophage based probes for pathogen detection.

    Science.gov (United States)

    Singh, Amit; Arutyunov, Denis; Szymanski, Christine M; Evoy, Stephane

    2012-08-01

    Rapid and specific detection of pathogenic bacteria is important for the proper treatment, containment and prevention of human, animal and plant diseases. Identifying unique biological probes to achieve a high degree of specificity and minimize false positives has therefore garnered much interest in recent years. Bacteriophages are obligate intracellular parasites that subvert bacterial cell resources for their own multiplication and production of disseminative new virions, which repeat the cycle by binding specifically to the host surface receptors and injecting genetic material into the bacterial cells. The precision of host recognition in phages is imparted by the receptor binding proteins (RBPs) that are often located in the tail-spike or tail fiber protein assemblies of the virions. Phage host recognition specificity has been traditionally exploited for bacterial typing using laborious and time consuming bacterial growth assays. At the same time this feature makes phage virions or RBPs an excellent choice for the development of probes capable of selectively capturing bacteria on solid surfaces with subsequent quick and automatic detection of the binding event. This review focuses on the description of pathogen detection approaches based on immobilized phage virions as well as pure recombinant RBPs. Specific advantages of RBP-based molecular probes are also discussed.

  2. A quantum spin-probe molecular microscope

    Science.gov (United States)

    Perunicic, V. S.; Hill, C. D.; Hall, L. T.; Hollenberg, L. C. L.

    2016-10-01

    Imaging the atomic structure of a single biomolecule is an important challenge in the physical biosciences. Whilst existing techniques all rely on averaging over large ensembles of molecules, the single-molecule realm remains unsolved. Here we present a protocol for 3D magnetic resonance imaging of a single molecule using a quantum spin probe acting simultaneously as the magnetic resonance sensor and source of magnetic field gradient. Signals corresponding to specific regions of the molecule's nuclear spin density are encoded on the quantum state of the probe, which is used to produce a 3D image of the molecular structure. Quantum simulations of the protocol applied to the rapamycin molecule (C51H79NO13) show that the hydrogen and carbon substructure can be imaged at the angstrom level using current spin-probe technology. With prospects for scaling to large molecules and/or fast dynamic conformation mapping using spin labels, this method provides a realistic pathway for single-molecule microscopy.

  3. Doubling strong lensing as a cosmological probe

    Science.gov (United States)

    Linder, Eric V.

    2016-10-01

    Strong gravitational lensing provides a geometric probe of cosmology in a unique manner through distance ratios involving the source and lens. This is well-known for the time delay distance derived from measured delays between lightcurves of the images of variable sources such as quasars. Recently, double source plane lens systems involving two constant sources lensed by the same foreground lens have been proposed as another probe, involving a different ratio of distances measured from the image positions and fairly insensitive to the lens modeling. Here we demonstrate that these two different sets of strong lensing distance ratios have strong complementarity in cosmological leverage. Unlike other probes, the double source distance ratio is actually more sensitive to the dark energy equation of state parameters w0 and wa than to the matter density Ωm, for low redshift lenses. Adding double source distance ratio measurements can improve the dark energy figure of merit by 40% for a sample of fewer than 100 low redshift systems, or even better for the optimal redshift distribution we derive.

  4. Eddy Current Flexible Probes for Complex Geometries

    Science.gov (United States)

    Gilles-Pascaud, C.; Decitre, J. M.; Vacher, F.; Fermon, C.; Pannetier, M.; Cattiaux, G.

    2006-03-01

    The inspection of materials used in aerospace, nuclear or transport industry is a critical issue for the safety of components exposed to stress or/and corrosion. The industry claims for faster, more sensitive, and more flexible techniques. Technologies based on Eddy Current (EC) flexible array probe and magnetic sensor with high sensitivity such as giant magneto-resistance (GMR) could be a good solution to detect surface-breaking flaws in complex shaped surfaces. The CEA has recently developed, with support from the French Institute for Radiological Protection and Nuclear Safety (IRSN), a flexible array probe based on micro-coils etched on Kapton. The probe's performances have been assessed for the inspection of reactor residual heat removal pipes, and for aeronautical applications within the framework of the European project VERDICT. The experimental results confirm the very good detection of narrow cracks on plane and curve shaped surfaces. This paper also describes the recent progresses concerning the application of GMR sensors to EC testing, and the results obtained for the detection of small surface breaking flaws.

  5. Antenna Near-Field Probe Station Scanner

    Science.gov (United States)

    Zaman, Afroz J. (Inventor); Lee, Richard Q. (Inventor); Darby, William G. (Inventor); Barr, Philip J. (Inventor); Lambert, Kevin M (Inventor); Miranda, Felix A. (Inventor)

    2011-01-01

    A miniaturized antenna system is characterized non-destructively through the use of a scanner that measures its near-field radiated power performance. When taking measurements, the scanner can be moved linearly along the x, y and z axis, as well as rotationally relative to the antenna. The data obtained from the characterization are processed to determine the far-field properties of the system and to optimize the system. Each antenna is excited using a probe station system while a scanning probe scans the space above the antenna to measure the near field signals. Upon completion of the scan, the near-field patterns are transformed into far-field patterns. Along with taking data, this system also allows for extensive graphing and analysis of both the near-field and far-field data. The details of the probe station as well as the procedures for setting up a test, conducting a test, and analyzing the resulting data are also described.

  6. The Trial of Katherine Harrison.

    Science.gov (United States)

    Woodward, Walter W.

    2003-01-01

    Presents a lesson plan in which the teacher and students participate in a mock trial of Katherine Harrison, who was accused of witchcraft in the seventeenth century. Provides background information about the trial, as well as primary sources of the testimonies given by witnesses during the trial. (CMK)

  7. The Trial of Katherine Harrison.

    Science.gov (United States)

    Woodward, Walter W.

    2003-01-01

    Presents a lesson plan in which the teacher and students participate in a mock trial of Katherine Harrison, who was accused of witchcraft in the seventeenth century. Provides background information about the trial, as well as primary sources of the testimonies given by witnesses during the trial. (CMK)

  8. Encouragement from Jupiter for Europe's Titan Probe

    Science.gov (United States)

    1996-04-01

    Huygens will transmit scientific information for 150 minutes, from the outer reaches of Titan's cold atmosphere and all the way down to its enigmatic surface. For comparison, the Jupiter Probe radioed scientific data for 58 minutes as it descended about 200 kilometres into the outer part of the atmosphere of the giant planet. The parachutes controlling various stages of Huygens' descent will rely upon a system for deployment designed and developed in Europe that is nevertheless similar to that used by the Jupiter Probe. The elaborate sequence of operations in Huygens worked perfectly during a dramatic drop test from a stratospheric balloon over Sweden in May 1995, which approximated as closely as possible to events on Titan. The performance of the American Probe at Jupiter renews the European engineers' confidence in their own descent control system, and also in the lithium sulphur-dioxide batteries which were chosen to power both Probes. "The systems work after long storage in space," comments Hamid Hassan, ESA's Project Manager for Huygens. "Huygens will spend seven years travelling to Saturn's vicinity aboard the Cassini Orbiter. The Jupiter Probe was a passenger in Galileo for six years before its release, so there is no reason to doubt that Huygens will work just as well." Huygens will enter the outer atmosphere of Titan at 20,000 kilometres per hour. A heat shield 2.7 metres in diameter will withstand the friction and slow the Probe to a speed at which parachutes can be deployed. The size of the parachute for the main phase of the descent is chosen to allow Huygens to reach the surface in about 2 hours. The batteries powering Huygens will last for about 21/2 hours. Prepared for surprises A different perspective on the Jupiter Probe comes from Jean-Pierre Lebreton, ESA's Project Scientist for Huygens. The results contradicted many preconceptions of the Galileo scientists, particularly about the abundance of water and the structure of cloud layers. Arguments

  9. A guide to clinical trials for cancer

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000823.htm A guide to clinical trials for cancer To use ... trial and where to find one. What is a Clinical Trial for Cancer? Clinical trials for cancer ...

  10. Enhanced chemiluminescence detection of glutathione based on isoluminol-PSM nanoparticles probe.

    Science.gov (United States)

    Ji, Xiaoting; Wang, Wei; Li, Xiaoqian; Chen, Yaoyao; Ding, Caifeng

    2016-04-01

    In this paper, a new chemiluminescence (CL) strategy was constructed for the determination of physiological thiols by using an isoluminol labeled nano-probe. The amino group on the surface of the magnetic beads (MBs) were converted into pyridyl disulfide groups by treatment with N-succinimidyl-3-(2-pyridyldithio)propionate (SPDP), in the meantime, isoluminol and thiolated signal DNA were labeled on the surface of the polystyrene microspheres (PSMs). By treating the SPDP activated MBs with the modified PSMs, isoluminol molecules on the surface of the PSMs, along with the thiolated signal DNA, were attached to the surface of the MBs through disulfide bonds to form a CL probe. In the presence of glutathione (GSH), the disulfide bonds could be cleaved readily. The isoluminol molecules modified on the surface of the PSMs released from the CL probes were detached by magnetic separation and transferred to the dark closet for CL detection of isoluminol-H2O2-HRP system. Using GSH detection as a model, we prove a linear dose response in the range from 5 × 10(-10) to 8 × 10(-8)M. The detection limit of this trial for GSH determined is 5 × 10(-10)M. The proposed design was successfully applied to the extracts of K562 cell for intracellular thiols detection, the average amount of thiols was about 4.114 × 10(-13)M per K562 cell.

  11. What is the most sensitive measure of water maze probe test performance?

    Directory of Open Access Journals (Sweden)

    Hamid R Maei

    2009-03-01

    Full Text Available The water maze is commonly used to assay spatial cognition, or, more generally, learning and memory in experimental rodent models. In the water maze, mice or rats are trained to navigate to a platform located below the water’s surface. Spatial learning is then typically assessed in a probe test, where the platform is removed from the pool and the mouse or rat is allowed to search for it. Performance in the probe test may then be evaluated using either occupancy-based (percent time in virtual quadrant [Q] or zone [Z] centered on former platform location, error-based (mean proximity to former platform location [P] or counting-based (platform crossings [X] measures. While these measures differ in their popularity, whether they differ in their ability to detect group differences is not known. To address this question we compiled 5 separate databases, containing more than 1600 mouse probe tests. Random selection of individual trials from respective databases then allowed us to simulate experiments with varying sample and effect sizes. Using this Monte Carlo-based method, we found that the P measure consistently outperformed the Q, Z and X measures in its ability to detect group differences. This was the case regardless of sample or effect size, and using both parametric and non-parametric statistical analyses. The relative superiority of P over other commonly used measures suggests that it is the most appropriate measure to employ in both low- and high-throughput water maze screens.

  12. Modeling the Insertion Mechanics of Flexible Neural Probes Coated with Sacrificial Polymers for Optimizing Probe Design

    Directory of Open Access Journals (Sweden)

    Sagar Singh

    2016-03-01

    Full Text Available Single-unit recording neural probes have significant advantages towards improving signal-to-noise ratio and specificity for signal acquisition in brain-to-computer interface devices. Long-term effectiveness is unfortunately limited by the chronic injury response, which has been linked to the mechanical mismatch between rigid probes and compliant brain tissue. Small, flexible microelectrodes may overcome this limitation, but insertion of these probes without buckling requires supporting elements such as a stiff coating with a biodegradable polymer. For these coated probes, there is a design trade-off between the potential for successful insertion into brain tissue and the degree of trauma generated by the insertion. The objective of this study was to develop and validate a finite element model (FEM to simulate insertion of coated neural probes of varying dimensions and material properties into brain tissue. Simulations were performed to predict the buckling and insertion forces during insertion of coated probes into a tissue phantom with material properties of brain. The simulations were validated with parallel experimental studies where probes were inserted into agarose tissue phantom, ex vivo chick embryonic brain tissue, and ex vivo rat brain tissue. Experiments were performed with uncoated copper wire and both uncoated and coated SU-8 photoresist and Parylene C probes. Model predictions were found to strongly agree with experimental results (<10% error. The ratio of the predicted buckling force-to-predicted insertion force, where a value greater than one would ideally be expected to result in successful insertion, was plotted against the actual success rate from experiments. A sigmoidal relationship was observed, with a ratio of 1.35 corresponding to equal probability of insertion and failure, and a ratio of 3.5 corresponding to a 100% success rate. This ratio was dubbed the “safety factor”, as it indicated the degree to which the coating

  13. Modeling the Insertion Mechanics of Flexible Neural Probes Coated with Sacrificial Polymers for Optimizing Probe Design.

    Science.gov (United States)

    Singh, Sagar; Lo, Meng-Chen; Damodaran, Vinod B; Kaplan, Hilton M; Kohn, Joachim; Zahn, Jeffrey D; Shreiber, David I

    2016-03-04

    Single-unit recording neural probes have significant advantages towards improving signal-to-noise ratio and specificity for signal acquisition in brain-to-computer interface devices. Long-term effectiveness is unfortunately limited by the chronic injury response, which has been linked to the mechanical mismatch between rigid probes and compliant brain tissue. Small, flexible microelectrodes may overcome this limitation, but insertion of these probes without buckling requires supporting elements such as a stiff coating with a biodegradable polymer. For these coated probes, there is a design trade-off between the potential for successful insertion into brain tissue and the degree of trauma generated by the insertion. The objective of this study was to develop and validate a finite element model (FEM) to simulate insertion of coated neural probes of varying dimensions and material properties into brain tissue. Simulations were performed to predict the buckling and insertion forces during insertion of coated probes into a tissue phantom with material properties of brain. The simulations were validated with parallel experimental studies where probes were inserted into agarose tissue phantom, ex vivo chick embryonic brain tissue, and ex vivo rat brain tissue. Experiments were performed with uncoated copper wire and both uncoated and coated SU-8 photoresist and Parylene C probes. Model predictions were found to strongly agree with experimental results (experiments. A sigmoidal relationship was observed, with a ratio of 1.35 corresponding to equal probability of insertion and failure, and a ratio of 3.5 corresponding to a 100% success rate. This ratio was dubbed the "safety factor", as it indicated the degree to which the coating should be over-designed to ensure successful insertion. Probability color maps were generated to visually compare the influence of design parameters. Statistical metrics derived from the color maps and multi-variable regression analysis confirmed

  14. A First/Third-Order Probe Correction Technique for Spherical Near-Field Antenna Measurements Using Three Probe Orientations

    DEFF Research Database (Denmark)

    Laitinen, Tommi; Breinbjerg, Olav

    2008-01-01

    A probe correction technique is described for spherical near-field antenna measurements based on sampling the near field for three probe orientations in each measurement direction. The technique applies to odd-order probes whose radiated field contains (significant) power only in the first (µ=±1)...

  15. Isolation of human minisatellite loci detected by synthetic tandem repeat probes: direct comparison with cloned DNA fingerprinting probes.

    Science.gov (United States)

    Armour, J A; Vergnaud, G; Crosier, M; Jeffreys, A J

    1992-08-01

    As a direct comparison with cloned 'DNA fingerprinting' probes, we present the results of screening an ordered array Charomid library for hypervariable human loci using synthetic tandem repeat (STR) probes. By recording the coordinates of positive hybridization signals, the subset of clones within the library detected by each STR probe can be defined, and directly compared with the set of clones detected by naturally occurring (cloned) DNA fingerprinting probes. The STR probes vary in the efficiency of detection of polymorphic minisatellite loci; among the more efficient probes, there is a strong overlap with the sets of clones detected by the DNA fingerprinting probes. Four new polymorphic loci were detected by one or more of the STR probes but not by any of the naturally occurring repeats. Sequence comparisons with the probe(s) used to detect the locus suggest that a relatively poor match, for example 10 out of 14 bases in a limited region of each repeat, is sufficient for the positive detection of tandem repeats in a clone in this type of library screening by hybridization. These results not only provide a detailed evaluation of the usefulness of STR probes in the isolation of highly variable loci, but also suggest strategies for the use of these multi-locus probes in screening libraries for clones from hypervariable loci.

  16. Electrical Conductivity Studies on Individual Conjugated Polymer Nanowires: Two-Probe and Four-Probe Results

    Directory of Open Access Journals (Sweden)

    Duvail JeanLuc

    2009-01-01

    Full Text Available Abstract Two- and four-probe electrical measurements on individual conjugated polymer nanowires with different diameters ranging from 20 to 190 nm have been performed to study their conductivity and nanocontact resistance. The two-probe results reveal that all the measured polymer nanowires with different diameters are semiconducting. However, the four-probe results show that the measured polymer nanowires with diameters of 190, 95–100, 35–40 and 20–25 nm are lying in the insulating, critical, metallic and insulting regimes of metal–insulator transition, respectively. The 35–40 nm nanowire displays a metal–insulator transition at around 35 K. In addition, it was found that the nanocontact resistance is in the magnitude of 104Ω at room temperature, which is comparable to the intrinsic resistance of the nanowires. These results demonstrate that four-probe electrical measurement is necessary to explore the intrinsic electronic transport properties of isolated nanowires, especially in the case of metallic nanowires, because the metallic nature of the measured nanowires may be coved by the nanocontact resistance that cannot be excluded by a two-probe technique.

  17. Langmuir Probe Distortions and Probe Compensation in an Inductively Coupled Plasma

    Science.gov (United States)

    Ji, J. S.; Cappelli, M. A.; Kim, J. S.; Rao, M. V. V. S.; Sharma, S. P.

    1999-01-01

    In many RF discharges, Langmuir probe measurements are usually made against a background of sinusoidal (and not so sinusoidal) fluctuations in the plasma parameters such as the plasma potential (Vp), the electron number density (ne), and the electron temperature (Te). The compensation of sinusoidal fluctuations in Vp has been extensively studied and is relatively well understood. Less attention has been paid to the possible distortions introduced by small fluctuations in plasma density and/or plasma temperature, which may arise in the sheath and pre-sheath regions of RF discharges. Here, we present the results of a model simulation of probe characteristics subject to fluctuations in both Vp and ne. The modeling of probe distortion due to possible fluctuations in Te is less straightforward. A comparison is presented of calculations with experimental measurements using a compensated and uncompensated Langmuir probe in an inductively coupled GEC reference cell plasma, operating on Ar and Ar/CF4 mixtures. The plasma parameters determined from the compensated probe characteristics are compared to previous measurements of others made in similar discharges, and to our own measurements of the average electron density derived from electrical impedance measurements.

  18. SMi's Conducting Clinical Trials in Europe.

    Science.gov (United States)

    Jago, Charlotte

    2009-12-01

    The Conducting Clinical Trials in Europe meeting, held in London, included topics covering new developments in the field of clinical trials and recommendations on how to best conduct a trial. This conference report highlights selected presentations on the state of affairs of trials in Europe, conducting trials in emerging markets, strategies for improving trials, trial design options, peri-approval and pediatric trials, and the role of key players, such as physicians. Company perspectives from Pfizer Inc and Nycomed are also included.

  19. The CHANGE trial

    DEFF Research Database (Denmark)

    Speyer, Helene; Christian Brix Nørgaard, Hans; Birk, Merete

    2016-01-01

    Life expectancy in patients with schizophrenia is reduced by 20 years for men and 15 years for women compared to the general population. About 60% of the excess mortality is due to physical illnesses, with cardiovascular disease being dominant. CHANGE was a randomized, parallel-group, superiority......, multi-centre trial with blinded outcome assessment, testing the efficacy of an intervention aimed to improve cardiovascular risk profile and hereby potentially reduce mortality. A total of 428 patients with schizophrenia spectrum disorders and abdominal obesity were recruited and centrally randomized 1...... cardiorespiratory fitness, physical activity, weight, diet and smoking. In conclusion, the CHANGE trial did not support superiority of individual lifestyle coaching or care coordination compared to treatment as usual in reducing cardiovascular risk in patients with schizophrenia spectrum disorders and abdominal...

  20. The Interstellar Ethics of Self-Replicating Probes

    Science.gov (United States)

    Cooper, K.

    Robotic spacecraft have been our primary means of exploring the Universe for over 50 years. Should interstellar travel become reality it seems unlikely that humankind will stop using robotic probes. These probes will be able to replicate themselves ad infinitum by extracting raw materials from the space resources around them and reconfiguring them into replicas of themselves, using technology such as 3D printing. This will create a colonising wave of probes across the Galaxy. However, such probes could have negative as well as positive consequences and it is incumbent upon us to factor self-replicating probes into our interstellar philosophies and to take responsibility for their actions.

  1. Probe design for expression arrays using OligoWiz

    DEFF Research Database (Denmark)

    Wernersson, Rasmus

    2014-01-01

    Since all measurements from a DNA microarray is dependant on the probes used, a good choice of probes is of vital importa nce when designing custom micro-arrays. This chapter describes how to de sign expression arrays using the “ OligoWiz ” software suite. The general desired features of good...... probes and the issues which probe design must address are introduced and a conceptual (rather than mathematical) description of how OligoWiz scores the quality of th e potential probes is presented. This is followed by a detailed step-by-step guide to designing expression arrays with OligoWiz....

  2. Plasma density perturbation caused by probes at low gas pressure

    Science.gov (United States)

    Sternberg, Natalia; Godyak, Valery

    2017-09-01

    An analysis of plasma parameter perturbations caused by a spherical probe immersed into a spherical plasma is presented for arbitrary collisionality and arbitrary ratios of probe to plasma dimensions. The plasma was modeled by the fluid plasma equations with ion inertia and nonlinear ion friction force that dominate plasma transport at low gas pressures. Significant depletion of the plasma density around the probe surface has been found. The area of plasma depletion coincides with the sensing area of different kinds of magnetic and microwave probes and will therefore lead to errors in data inferred from measurements with such probes.

  3. An exemplar-familiarity model predicts short-term and long-term probe recognition across diverse forms of memory search.

    Science.gov (United States)

    Nosofsky, Robert M; Cox, Gregory E; Cao, Rui; Shiffrin, Richard M

    2014-11-01

    Experiments were conducted to test a modern exemplar-familiarity model on its ability to account for both short-term and long-term probe recognition within the same memory-search paradigm. Also, making connections to the literature on attention and visual search, the model was used to interpret differences in probe-recognition performance across diverse conditions that manipulated relations between targets and foils across trials. Subjects saw lists of from 1 to 16 items followed by a single item recognition probe. In a varied-mapping condition, targets and foils could switch roles across trials; in a consistent-mapping condition, targets and foils never switched roles; and in an all-new condition, on each trial a completely new set of items formed the memory set. In the varied-mapping and all-new conditions, mean correct response times (RTs) and error proportions were curvilinear increasing functions of memory set size, with the RT results closely resembling ones from hybrid visual-memory search experiments reported by Wolfe (2012). In the consistent-mapping condition, new-probe RTs were invariant with set size, whereas old-probe RTs increased slightly with increasing study-test lag. With appropriate choice of psychologically interpretable free parameters, the model accounted well for the complete set of results. The work provides support for the hypothesis that a common set of processes involving exemplar-based familiarity may govern long-term and short-term probe recognition across wide varieties of memory- search conditions.

  4. Gateways to clinical trials.

    Science.gov (United States)

    Bayés, M; Rabasseda, X; Prous, J R

    2007-01-01

    Gateways to Clinical Trials are a guide to the most recent clinical trials in current literature and congresses. The data the following tables have been retrieved from the Clinical Trials Knowledge Area of Prous Science Integrity, the drug discovery and development portal, http://integrity.prous.com. This issues focuses on the following selection of drugs: 4'-Thio-ara-C, 5-methyltetrahydrofolate; ABT-089, AD-237, AF-37702, alvocidib hydrochloride, apricitabine, armodafinil, atrasentan, AVE-5883, avian influenza vaccine, azimilide hydrochloride; Banoxantrone, BIBF-1120; CD34+ cells, certolizumab pegol, CHIR-258, cilansetron, CoFactor, CX-3543, cystemustine; D-003, dexloxiglumide, DMXB-anabaseine; Ecogramostim, elcometrine, elcometrine/ethinylestradiol, etravirine; Fenretinide, fingolimod hydrochloride, fospropofol disodium; Gaboxadol, gestodene, glutamine; Human insulin, hyaluronic acid; Incyclinide, indacaterol, ispronicline, istradefylline; Labradimil, lamifiban, lapatinib, L-arginine hydrochloride, liposomal cisplatin, liposome encapsulated paclitaxel, LY-517717; Manidipine hydrochloride/delapril hydrochloride, maraviroc, MBP(82-98), MD-0727, MDX-214, melanotan I, MMR vaccine; Nacystelyn, nalfurafine hydrochloride, nibentan, nilotinib, NK-105; OBI-1, oblimersen sodium, olmesartan medoxomil, olmesartan medoxomil/hydrochlorothiazide, oregovomab; Pexelizumab, PG-116800, PG-CPT, PHA-794428, prasugrel; RC-3095, rDNA insulin, RFB4(dsFv)-PE38, rhEndostatin, rhenium Re-186 etidronate, rhGM-CSF, roflumilast, romidepsin; Sarcosine, SGLU1, SGN-40, succinobucol; TAU, teduglutide, telatinib, tesofensine, tipifarnib, tirapazamine, TKA-731, tolvaptan, trabectedin; Vaccimel, vatalanib succinate, velafermin, vildagliptin, vinflunine; XP-19986; YM-155.

  5. Design and analysis of mismatch probes for long oligonucleotide microarrays

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Zhou, Jizhong

    2008-08-15

    Nonspecific hybridization is currently a major concern with microarray technology. One of most effective approaches to estimating nonspecific hybridizations in oligonucleotide microarrays is the utilization of mismatch probes; however, this approach has not been used for longer oligonucleotide probes. Here, an oligonucleotide microarray was constructed to evaluate and optimize parameters for 50-mer mismatch probe design. A perfect match (PM) and 28 mismatch (MM) probes were designed for each of ten target genes selected from three microorganisms. The microarrays were hybridized with synthesized complementary oligonucleotide targets at different temperatures (e.g., 42, 45 and 50 C). In general, the probes with evenly distributed mismatches were more distinguishable than those with randomly distributed mismatches. MM probes with 3, 4 and 5 mismatched nucleotides were differentiated for 50-mer oligonucleotide probes hybridized at 50, 45 and 42 C, respectively. Based on the experimental data generated from this study, a modified positional dependent nearest neighbor (MPDNN) model was constructed to adjust the thermodynamic parameters of matched and mismatched dimer nucleotides in the microarray environment. The MM probes with four flexible positional mismatches were designed using the newly established MPDNN model and the experimental results demonstrated that the redesigned MM probes could yield more consistent hybridizations. Conclusions: This study provides guidance on the design of MM probes for long oligonucleotides (e.g., 50 mers). The novel MPDNN model has improved the consistency for long MM probes, and this modeling method can potentially be used for the prediction of oligonucleotide microarray hybridizations.

  6. FABRICATION AND APPLICATION OF NEARFIELD OPTICAL FIBRE PROBE

    Institute of Scientific and Technical Information of China (English)

    SUN JIA-LIN; XU JIAN-HUA; TIAN GUANG-YAN; GUo JI-HUA; ZHAO JUN; XIE AI-FANG; ZHANG ZE-BO

    2001-01-01

    In this paper, the fabrication of a large cone angle near-field optical fibre probe, using the two-step chemical etching method and bent probe, is introduced, and the controlling parameters of the coated Cr-Al film at the probe tip are presented. The scanning electron microscopy images display that the tip diameter of the uncoated large cone angle fibre probe obtained is less than 50nm, the cone angle over 90°, and the diameter of light aperture at the coated probe tip is less than 100nm. The measured results of the optical transmission efficiency for various probe tips show that the uncoated straight optical fibre probe, film-coated straight probe and film-coated bent probe are 3×10-1, 2×10-3, and l×10-4 times that of the flat fibre probe, respectively. In addition, the force images and near-field optical images of a standard sample are acquired using a large cone angle and film-coated bent probe.

  7. Design and analysis of mismatch probes for long oligonucleotide microarrays

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Zhou, Jizhong

    2008-08-15

    Nonspecific hybridization is currently a major concern with microarray technology. One of most effective approaches to estimating nonspecific hybridizations in oligonucleotide microarrays is the utilization of mismatch probes; however, this approach has not been used for longer oligonucleotide probes. Here, an oligonucleotide microarray was constructed to evaluate and optimize parameters for 50-mer mismatch probe design. A perfect match (PM) and 28 mismatch (MM) probes were designed for each of ten target genes selected from three microorganisms. The microarrays were hybridized with synthesized complementary oligonucleotide targets at different temperatures (e.g., 42, 45 and 50 C). In general, the probes with evenly distributed mismatches were more distinguishable than those with randomly distributed mismatches. MM probes with 3, 4 and 5 mismatched nucleotides were differentiated for 50-mer oligonucleotide probes hybridized at 50, 45 and 42 C, respectively. Based on the experimental data generated from this study, a modified positional dependent nearest neighbor (MPDNN) model was constructed to adjust the thermodynamic parameters of matched and mismatched dimer nucleotides in the microarray environment. The MM probes with four flexible positional mismatches were designed using the newly established MPDNN model and the experimental results demonstrated that the redesigned MM probes could yield more consistent hybridizations. Conclusions: This study provides guidance on the design of MM probes for long oligonucleotides (e.g., 50 mers). The novel MPDNN model has improved the consistency for long MM probes, and this modeling method can potentially be used for the prediction of oligonucleotide microarray hybridizations.

  8. Effects of different manual periodontal probes on periodontal measurements

    Science.gov (United States)

    Holtfreter, Birte; Alte, Dietrich; Schwahn, Christian; Desvarieux, Moïse; Kocher, Thomas

    2013-01-01

    Aim To quantify the digit preference effect for three manual periodontal probes and to calculate correction values to enable comparison of studies with equal recording protocols, but different periodontal probes. Material and Methods A prospective in vivo crossover study was conducted with a six-sequence three-period design. Six examiners assessed attachment loss (AL), probing pocket depth (PD) and gingiva height (GH) at four surfaces, full-mouth, in six generally healthy subjects using three manual probes: PCP11 (3-3-3-2 mm increments), PCP2 (2 mm increments), and PCPUNC15 (1 mm increments). Results Distributions of AL, PD and GH differed between probes (p < 0.001). Compared with PCPUNC15, periodontal measurements coinciding with probe markings of PCP11 and PCP2, respectively, were preferentially named by examiners. Digit preference was most pronounced for PD, but less for AL and GH. In multilevel models, PD differed significantly between all three probes (p < 0.05); probe- and examiner-related effects were also observed for AL and GH. Correction values for pairwise combinations of probes were determined. Conclusions We provided empirical evidence and quantified the effect of probe type on periodontal measurements. Differences in probe type should be considered when comparing periodontal data within and between epidemiological studies and appropriate corrections, provided here, should be applied. PMID:22924328

  9. Langmuir probe in collisionless and collisional plasma including dusty plasma

    Science.gov (United States)

    Bose, Sayak; Kaur, Manjit; Chattopadhyay, P. K.; Ghosh, J.; Saxena, Y. C.; Pal, R.

    2017-04-01

    Measurements of local plasma parameters in dusty plasma are crucial for understanding the physics issues related to such systems. The Langmuir probe, a small electrode immersed in the plasma, provides such measurements. However, designing of a Langmuir probe system in a dusty plasma environment demands special consideration. First, the probe has to be miniaturized enough so that its perturbation on the ambient dust structure is minimal. At the same time, the probe dimensions must be such that a well-defined theory exists for interpretation of its characteristics. The associated instrumentation must also support the measurement of current collected by the probe with high signal to noise ratio. The most important consideration, of course, comes from the fact that the probes are prone to dust contamination, as the dust particles tend to stick to the probe surface and alter the current collecting area in unpredictable ways. This article describes the design and operation of a Langmuir probe system that resolves these challenging issues in dusty plasma. In doing so, first, different theories that are used to interpret the probe characteristics in collisionless as well as in collisional regimes are discussed, with special emphasis on application. The critical issues associated with the current-voltage characteristics of Langmuir probe obtained in different operating regimes are discussed. Then, an algorithm for processing these characteristics efficiently in presence of ion-neutral collisions in the probe sheath is presented.

  10. The role of probe oxide in local surface conductivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, C. J.; Kryvchenkova, O.; Wilson, L. S. J.; Maffeis, T. G. G.; Cobley, R. J. [Multidisciplinary Nanotechnology Centre, College of Engineering, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Kalna, K. [Electronic Systems Design Centre, College of Engineering, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2015-05-07

    Local probe methods can be used to measure nanoscale surface conductivity, but some techniques including nanoscale four point probe rely on at least two of the probes forming the same low resistivity non-rectifying contact to the sample. Here, the role of probe shank oxide has been examined by carrying out contact and non-contact I V measurements on GaAs when the probe oxide has been controllably reduced, both experimentally and in simulation. In contact, the barrier height is pinned but the barrier shape changes with probe shank oxide dimensions. In non-contact measurements, the oxide modifies the electrostatic interaction inducing a quantum dot that alters the tunneling behavior. For both, the contact resistance change is dependent on polarity, which violates the assumption required for four point probe to remove probe contact resistance from the measured conductivity. This has implications for all nanoscale surface probe measurements and macroscopic four point probe, both in air and vacuum, where the role of probe oxide contamination is not well understood.

  11. Non-toxic fluorescent phosphonium probes to detect mitochondrial potential

    Science.gov (United States)

    Šarić, Ana; Crnolatac, Ivo; Bouillaud, Frédéric; Sobočanec, Sandra; Mikecin, Ana-Matea; Mačak Šafranko, Željka; Delgeorgiev, Todor; Piantanida, Ivo; Balog, Tihomir; Petit, Patrice X.

    2017-03-01

    We evaluated our phosphonium-based fluorescent probes for selective staining of mitochondria. Currently used probes for monitoring mitochondrial membrane potential show varying degrees of interference with cell metabolism, photo-induced damage and probe binding. Here presented probes are characterised by highly efficient cellular uptake and specific accumulation in mitochondria. Fluorescent detection of the probes was accomplished using flow cytometry and confocal microscopy imaging of yeast and mammalian cells. Toxicity analysis (impedimetry—xCELLigence for the cellular proliferation and Seahorse technology for respiratory properties) confirms that these dyes exhibit no-toxicity on mitochondrial or cellular functioning even for long time incubation. The excellent chemical and photophysical stability of the dyes makes them promising leads toward improved fluorescent probes. Therefore, the probes described here offer to circumvent the problems associated with existing-probe’s limitations.

  12. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    黄承志; 李原芳; 黄新华; 范美坤

    2000-01-01

    The microarray of DNA probes with 5’ -NH2 and 5’ -Tex/3’ -NH2 modified terminus on 10 um carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) is characterized in the preseni paper. it was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentra-tion of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  13. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The microarray of DNA probes with 5′-NH2 and 5′-Tex/3′-NH2 modified terminus on 10 m m carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)- carbodiimide (EDC) is characterized in the present paper. It was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentration of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  14. An improved fabrication method for carbon nanotube probe

    Institute of Scientific and Technical Information of China (English)

    XU Zong-wei; GUO Li-qiu; DONG Shen; ZHAO Qing-liang

    2008-01-01

    An improved arc discharge method is developed to fabricate the carbon nanotube probe.In this method,the silicon probe and the carbon nanotube were manipulated under an optical microscope.When the silicon probe and the carbon nanotube were very close,30-60 V dc or ac was applied between them,and the carbon nanotube was divided and attached to the end of the silicon probe.Comparing with the arc discharge method,the new method need not coat the silicon probe with metal in advance,which Can greatly reduce the fabrication difficulty and cost.The fabricated carbon nanotube probe exhibits the good property of hish aspect ratio and can reflect the true topography more accurately than the silicon probe.

  15. Reducing Plasma Perturbations with Segmented Metal Shielding on Electrostatic Probes

    Energy Technology Data Exchange (ETDEWEB)

    Staack, D.; Raitses, Y.; Fisch N.J.

    2002-10-02

    Electrostatic probes are widely used to measure spatial plasma parameters in the quasi-neutral plasma created in Hall thrusters and similar E x B electric discharge devices. Significant perturbations of the plasma, induced by such probes, can mask the actual physics involved in operation of these devices. In an attempt to reduce these perturbations in Hall thrusters, the perturbations were examined by varying the component material, penetration distance, and residence time of various probe designs. This study leads us to a conclusion that secondary electron emission from insulator ceramic tubes of the probe can affect local changes of the plasma parameters causing plasma perturbations. A probe design, which consists of a segmented metal shielding of the probe insulator, is suggested to reduce these perturbations. This new probe design can be useful for plasma applications in which the electron temperature is sufficient to produce secondary electron emission by interaction of plasma electrons with dielectric materials.

  16. Empirical evaluation of oligonucleotide probe selection for DNA microarrays.

    Directory of Open Access Journals (Sweden)

    Jennifer G Mulle

    Full Text Available DNA-based microarrays are increasingly central to biomedical research. Selecting oligonucleotide sequences that will behave consistently across experiments is essential to the design, production and performance of DNA microarrays. Here our aim was to improve on probe design parameters by empirically and systematically evaluating probe performance in a multivariate context. We used experimental data from 19 array CGH hybridizations to assess the probe performance of 385,474 probes tiled in the Duchenne muscular dystrophy (DMD region of the X chromosome. Our results demonstrate that probe melting temperature, single nucleotide polymorphisms (SNPs, and homocytosine motifs all have a strong effect on probe behavior. These findings, when incorporated into future microarray probe selection algorithms, may improve microarray performance for a wide variety of applications.

  17. Empirical evaluation of oligonucleotide probe selection for DNA microarrays.

    Science.gov (United States)

    Mulle, Jennifer G; Patel, Viren C; Warren, Stephen T; Hegde, Madhuri R; Cutler, David J; Zwick, Michael E

    2010-03-29

    DNA-based microarrays are increasingly central to biomedical research. Selecting oligonucleotide sequences that will behave consistently across experiments is essential to the design, production and performance of DNA microarrays. Here our aim was to improve on probe design parameters by empirically and systematically evaluating probe performance in a multivariate context. We used experimental data from 19 array CGH hybridizations to assess the probe performance of 385,474 probes tiled in the Duchenne muscular dystrophy (DMD) region of the X chromosome. Our results demonstrate that probe melting temperature, single nucleotide polymorphisms (SNPs), and homocytosine motifs all have a strong effect on probe behavior. These findings, when incorporated into future microarray probe selection algorithms, may improve microarray performance for a wide variety of applications.

  18. Organo luminescent semiconductor nanocrystal probes for biological applications and process for making and using such probes

    Science.gov (United States)

    Weiss, Shimon; Bruchez, Jr., Marcel; Alivisatos, Paul

    2008-01-01

    A semiconductor nanocrystal compound is described capable of linking to an affinity molecule. The compound comprises (1) a semiconductor nanocrystal capable of emitting electromagnetic radiation and/or absorbing energy, and/or scattering or diffracting electromagnetic radiation--when excited by an electromagnetic radiation source or a particle beam; and (2) an affinity molecule linked to the semiconductor nanocrystal. The semiconductor nanocrystal is linked to an affinity molecule to form a semiconductor nanocrystal probe capable of bonding with a detectable substance. Exposure of the semiconductor nanocrystal to excitation energy will excite the semiconductor nanocrystal causing the emission of electromagnetic radiation. Further described are processes for respectively: making the luminescent semiconductor nanocrystal compound; making the semiconductor nanocrystal probe; and using the probe to determine the presence of a detectable substance in a material.

  19. Refinement of a thermal threshold probe to prevent burns.

    Science.gov (United States)

    Dixon, M J; Taylor, P M; Slingsby, L C; Murrell, J C

    2016-02-01

    Thermal threshold testing is commonly used for pain research. The stimulus may cause burning and merits prevention. Thermal probe modifications hypothesized to reduce burning were evaluated for practicality and effect. Studies were conducted on two humans and eight cats. Unmodified probe 0 was tested on two humans and promising modifications were also evaluated on cats. Probe 1 incorporated rapid cooling after threshold was reached: probe 1a used a Peltier system and probe 1b used water cooling. Probe 2 released skin contact immediately after threshold. Probe 3 (developed in the light of evidence of 'hot spots' in probe 0) incorporated reduced thermal mass and even heating across the skin contact area. Human skin was heated to 48℃ (6℃ above threshold) and the resulting burn was evaluated using area of injury and a simple descriptive scale (SDS). Probe 1a cooled the skin but required further heat dissipation, excessive power, was not 'fail-safe' and was inappropriate for animal mounting. Probe 1b caused less damage than no cooling (27 ± 13 and 38 ± 11 mm(2) respectively, P = 0.0266; median SDS 1.5 and 4 respectively, P = 0.0317) but was cumbersome. Probe 2 was unwieldy and was not evaluated further. Probe 3 produced even heating without blistering in humans. With probe 3 in cats, after opioid treatment, thermal threshold reached cut-out (55℃) on 24 occasions, exceeded 50℃ in a further 32 tests and exceeded 48℃ in the remainder. No skin damage was evident immediately after testing and mild hyperaemia in three cats at 2-3 days resolved rapidly. Probe 3 appeared to be suitable for thermal threshold testing.

  20. The D3-probe-D7 brane holographic fractional topological insulator

    CERN Document Server

    Kristjansen, Charlotte

    2016-01-01

    The D3-probe-D7 brane system, oriented so as to have 2+1-dimensional Poincare symmetry, is argued to be the holographic representation of a strongly correlated fractional topological insulator which exhibits a zero-field quantized Hall effect with half-units of Hall conductivity. The phase diagram of the system with charge density and external magnetic field is found and, as well as charge gapped quantum Hall states, it exhibits metallic and semi-metallic phases with interesting behaviours. The relationship of this to other models of fractional topological insulators is discussed.

  1. Kinetic viability assays using DRAQ7 probe.

    Science.gov (United States)

    Wlodkowic, Donald; Akagi, Jin; Dobrucki, Jurek; Errington, Rachel; Smith, Paul J; Takeda, Kazuo; Darzynkiewicz, Zbigniew

    2013-07-01

    Cell death within cell populations is a stochastic process where cell-to-cell variation in temporal progression through the various stages of cell death arises from asynchrony of subtle fluctuations in the signaling pathways. Most cell death assays rely on detection of the specific marker of cell demise at the end-point of cell culturing. Such an approach cannot account for the asynchrony and the stochastic nature of cell response to the death-inducing signal. There is a need therefore for rapid and high-throughput bioassays capable of continuously tracking viability of individual cells from the time of encountering a stress signal up to final stages of their demise. In this context, a new anthracycline derivative, DRAQ7, is gaining increasing interest as an easy-to-use marker capable of long-term monitoring of cell death in real-time. This novel probe neither penetrates the plasma membrane of living cells nor does it affect the cells' susceptibility to the death-inducing agents. However, when the membrane integrity is compromised, DRAQ7 enters cells undergoing demise and binds readily to nuclear DNA to report cell death. Here, we provide three sets of protocols for viability assays using DRAQ7 probe. The first protocol describes the innovative use of single-color DRAQ7 real-time assay to dynamically track cell viability. The second protocol outlines a simplified end-point DRAQ7 staining approach. The final protocol highlights the real-time and multiparametric apoptosis assay utilizing DRAQ7 dye concurrently with tetramethylrhodamine methyl ester (TMRM), the mitochondrial trans-membrane electrochemical potential (ΔΨm) sensing probe.

  2. Development of nanowire arrays for neural probe

    Science.gov (United States)

    Abraham, Jose K.; Xie, Jining; Varadan, Vijay K.

    2005-05-01

    It is already established that functional electrical stimulation is an effective way to restore many functions of the brain in disabled individuals. The electrical stimulation can be done by using an array of electrodes. Neural probes stimulate or sense the biopotentials mainly through the exposed metal sites. These sites should be smaller relative to the spatial potential distribution so that any potential averaging in the sensing area can be avoided. At the same time, the decrease in size of these sensing sites is limited due to the increase in impedance levels and the thermal noise while decreasing its size. It is known that current density in a planar electrode is not uniform and a higher current density can be observer around the perimeter of the electrodes. Electrical measurements conducted on many nanotubes and nanowires have already proved that it could be possible to use for current density applications and the drawbacks of the present design in neural probes can be overcome by incorporating many nanotechnology solutions. In this paper we present the design and development of nanowire arrays for the neural probe for the multisite contact which has the ability to collect and analyze isolated single unit activity. An array of vertically grown nanowires is used as contact site and many of such arrays can be used for stimulating as well as recording sites. The nanolevel interaction and wireless communication solution can extend to applications involving the treatment of many neurological disorders including Parkinson"s disease, Alzheimer"s disease, spinal injuries and the treatment of blindness and paralyzed patients with minimal or no invasive surgical procedures.

  3. Quantitative microbial ecology through stable isotope probing.

    Science.gov (United States)

    Hungate, Bruce A; Mau, Rebecca L; Schwartz, Egbert; Caporaso, J Gregory; Dijkstra, Paul; van Gestel, Natasja; Koch, Benjamin J; Liu, Cindy M; McHugh, Theresa A; Marks, Jane C; Morrissey, Ember M; Price, Lance B

    2015-11-01

    Bacteria grow and transform elements at different rates, and as yet, quantifying this variation in the environment is difficult. Determining isotope enrichment with fine taxonomic resolution after exposure to isotope tracers could help, but there are few suitable techniques. We propose a modification to stable isotope probing (SIP) that enables the isotopic composition of DNA from individual bacterial taxa after exposure to isotope tracers to be determined. In our modification, after isopycnic centrifugation, DNA is collected in multiple density fractions, and each fraction is sequenced separately. Taxon-specific density curves are produced for labeled and nonlabeled treatments, from which the shift in density for each individual taxon in response to isotope labeling is calculated. Expressing each taxon's density shift relative to that taxon's density measured without isotope enrichment accounts for the influence of nucleic acid composition on density and isolates the influence of isotope tracer assimilation. The shift in density translates quantitatively to isotopic enrichment. Because this revision to SIP allows quantitative measurements of isotope enrichment, we propose to call it quantitative stable isotope probing (qSIP). We demonstrated qSIP using soil incubations, in which soil bacteria exhibited strong taxonomic variations in (18)O and (13)C composition after exposure to [(18)O]water or [(13)C]glucose. The addition of glucose increased the assimilation of (18)O into DNA from [(18)O]water. However, the increase in (18)O assimilation was greater than expected based on utilization of glucose-derived carbon alone, because the addition of glucose indirectly stimulated bacteria to utilize other substrates for growth. This example illustrates the benefit of a quantitative approach to stable isotope probing.

  4. The Methodology of Probe Design with Better Resolution and Less Resistive Donut Probe to Achieve the Best Performance

    Institute of Scientific and Technical Information of China (English)

    Mohammad Ismail Talukder; Pepe Siy; Gregory Auner; Jinsheng Zhang

    2009-01-01

    Probes are the interface between microsystems and bio-cells. The ideal interface is one-to-one interface. Though various research groups have been able to establish some sort of interfaces after many years of research, they are very crude. Neurons are millions in numbers, whereas the prostheses successfully built so far have only a few hundred probes at best. Creating an ef-fective interface is still far away. Though we have micro-and nano-technologies, we couldn't build a prosthesis with an effective resolution. Main reasons behind it are the type of probe being used and the poor design of the probe. To address this problem, we developed a methodology to design a probe and an array of probes with better resolution and less resistive donut probe. This methodology helps us to design a probe optimizing all the parameters. We presented our methodology through a design that is capable of 70 pan penetration inside the tissue. The tissue heating by our designed probe is only 0.411℃. We also characterized the donut probe, which could be used by any research group to design a donut probe of their specific need.

  5. Ionization probes of molecular structure and chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, P.M. [State Univ. of New York, Stony Brook (United States)

    1993-12-01

    Various photoionization processes provide very sensitive probes for the detection and understanding of the spectra of molecules relevant to combustion processes. The detection of ionization can be selective by using resonant multiphoton ionization or by exploiting the fact that different molecules have different sets of ionization potentials. Therefore, the structure and dynamics of individual molecules can be studied even in a mixed sample. The authors are continuing to develop methods for the selective spectroscopic detection of molecules by ionization, and to use these methods for the study of some molecules of combustion interest.

  6. Probing the Big Bang with LEP

    Science.gov (United States)

    Schramm, David N.

    1990-01-01

    It is shown that LEP probes the Big Bang in two significant ways: (1) nucleosynthesis, and (2) dark matter constraints. In the first case, LEP verifies the cosmological standard model prediction on the number of neutrino types, thus strengthening the conclusion that the cosmological baryon density is approximately 6 percent of the critical value. In the second case, LEP shows that the remaining non-baryonic cosmological matter must be somewhat more massive and/or more weakly interacting than the favorite non-baryonic dark matter candidates of a few years ago.

  7. Probes for anionic cell surface detection

    Science.gov (United States)

    Smith, Bradley D.

    2013-03-05

    Embodiments of the present invention are generally directed to compositions comprising a class of molecular probes for detecting the presence of anionic cell surfaces. Embodiments include compositions that are enriched for these compositions and preparations, particularly preparations suitable for use as laboratory/clinical reagents and diagnostic indicators, either alone or as part of a kit. An embodiment of the invention provides for a highly selective agent useful in the discernment and identification of dead or dying cells, such as apoptotic cells, in a relatively calcium-free environment. An embodiment of the invention provides a selective agent for the identification of bacteria in a mixed population of bacterial cells and nonbacterial cells.

  8. Nanoscale microwave microscopy using shielded cantilever probes

    KAUST Repository

    Lai, Keji

    2011-04-21

    Quantitative dielectric and conductivity mapping in the nanoscale is highly desirable for many research disciplines, but difficult to achieve through conventional transport or established microscopy techniques. Taking advantage of the micro-fabrication technology, we have developed cantilever-based near-field microwave probes with shielded structures. Sensitive microwave electronics and finite-element analysis modeling are also utilized for quantitative electrical imaging. The system is fully compatible with atomic force microscope platforms for convenient operation and easy integration of other modes and functions. The microscope is ideal for interdisciplinary research, with demonstrated examples in nano electronics, physics, material science, and biology.

  9. Probing the Big Bang with LEP

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, D.N. (Chicago Univ., IL (USA) Fermi National Accelerator Lab., Batavia, IL (USA))

    1990-06-01

    It is shown that LEP probes the Big Bang in two significant ways: (1) nucleosynthesis and (2) dark matter constraints. In the first case, LEP verifies the cosmological standard model prediction on the number of neutrino types, thus strengthening the conclusion that the cosmological baryon density is {approximately}6% of the critical value. In the second case, LEP shows that the remaining non-baryonic cosmological matter must be somewhat more massive and/or more weakly interacting that the favorite non-baryonic dark matter candidates of a few years ago. 59 refs., 4 figs., 2 tabs.

  10. Probing resonance matter with virtual photons

    OpenAIRE

    2010-01-01

    In the energy domain of 1-2 GeV per nucleon, HADES has measured rare penetrating probes (e+e-) in C+C, Ar+KCl, d+p, p+p and p+Nb collisions. For the first time the electron pairs were reconstructed from quasi-free n+p sub-reactions by detecting the proton spectator from the deuteron breakup. An experimentally constrained NN reference spectrum was established. Our results demonstrate that the gross features of di-electron spectra in C+C collisions can be explained as a superposition of indepen...

  11. Hall probes: physics and application to magnetometry

    CERN Document Server

    Sanfilippo, S

    2010-01-01

    This lecture aims to present an overview of the properties of Hall effect devices. Descriptions of the Hall phenomenon, a review of the Hall effect device characteristics and of the various types of probes are presented. Particular attention is paid to the recent development of three-axis sensors and the related techniques to cancel the offsets and the planar Hall effect. The lecture introduces the delicate problem of the calibration of a three-dimensional sensor and ends with a section devoted to magnetic measurements in conventional beam line magnets and undulators.

  12. Probing (topological) Floquet states through DC transport

    Science.gov (United States)

    Fruchart, M.; Delplace, P.; Weston, J.; Waintal, X.; Carpentier, D.

    2016-01-01

    We consider the differential conductance of a periodically driven system connected to infinite electrodes. We focus on the situation where the dissipation occurs predominantly in these electrodes. Using analytical arguments and a detailed numerical study we relate the differential conductances of such a system in two and three terminal geometries to the spectrum of quasi-energies of the Floquet operator. Moreover these differential conductances are found to provide an accurate probe of the existence of gaps in this quasi-energy spectrum, being quantized when topological edge states occur within these gaps. Our analysis opens the perspective to describe the intermediate time dynamics of driven mesoscopic conductors as topological Floquet filters.

  13. Atom Probe Tomography of Nanoscale Electronic Materials

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David J.; Prosa, Ty J.; Perea, Daniel E.; Inoue, Hidekazu; Mangelinck, D.

    2016-01-01

    Atom probe tomography (APT) is a mass spectrometry based on time-of-flight measurements which also concurrently produces 3D spatial information. The reader is referred to any of the other papers in this volume or to the following references for further information 4–8. The current capabilities of APT, such as detecting a low number of dopant atoms in nanoscale devices or segregation at a nanoparticle interface, make this technique an important component in the nanoscale metrology toolbox. In this manuscript, we review some of the applications of APT to nanoscale electronic materials, including transistors and finFETs, silicide contact microstructures, nanowires, and nanoparticles.

  14. Probing leptoquark production at IceCube

    CERN Document Server

    Anchordoqui, L A; Dumm, D G; Goldberg, H; Halzen, F; Anchordoqui, Luis A.; Canal, Carlos A. Garcia; Dumm, Daniel Gomez; Goldberg, Haim; Halzen, Francis

    2006-01-01

    We emphasize the inelasticity distribution of events detected at the IceCube neutrino telescope as an important tool for revealing new physics. This is possible because the unique energy resolution at this facility allows to separately assign the energy fractions for emergent muons and taus in neutrino interactions. As a particular example, we explore the possibility of probing second and third generation leptoquark parameter space (coupling and mass). We show that production of leptoquarks with masses \\agt 250 GeV and diagonal generation couplings of O(1) can be directly tested if the cosmic neutrino flux is at the Waxman-Bahcall level.

  15. Spacetime, Spin and Gravity Probe B

    CERN Document Server

    Overduin, James M

    2015-01-01

    It is more important than ever to push experimental tests of gravitational theory to the limits of existing technology in both range and sensitivity. This brief review focuses on spin-based tests of General Relativity and their implications for alternative, mostly non-metric theories of gravity motivated by the challenge of unification with the Standard Model of particle physics. The successful detection of geodetic precession and frame-dragging by Gravity Probe B places new constraints on a number of these theories, and increases our confidence in the theoretical mechanisms underpinning current ideas in astrophysics and cosmology.

  16. Probing CP violation systematically in differential distributions

    CERN Document Server

    Durieux, Gauthier

    2015-01-01

    We revisit the topic of triple-product asymmetries which probe CP violation through differential distributions. We construct distributions with well-defined discrete symmetry properties and characterize the asymmetries formed upon them. It is stressed that the simplest asymmetries may not be optimal. We explore systematic generalizations having limited reliance on the process dynamics and phase-space parametrization. They exploit larger fractions of the information contained in differential distributions and may lead to increased sensitivities to CP violation. Our detailed treatment of the case of spinless four-body decays paves the way for further experimental studies.

  17. Phoenix's Probe Inserted in Martian Soil

    Science.gov (United States)

    2008-01-01

    The Phoenix Mars lander's robotic-arm camera took this image of the spacecraft's thermal and electrical-conductivity probe (TECP) inserted into Martian soil on day 149 of the mission. Phoenix landed on Mars' northern plains on May 25, 2008, landing. The robotic-arm camera acquired this image at 16:02:41 local solar time. The camera pointing was elevation -72.6986 degrees and azimuth 2.1093 degrees. The Phoenix mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  18. Iron-sulfide crystals in probe deposits

    DEFF Research Database (Denmark)

    Laursen, Karin; Frandsen, Flemming

    1998-01-01

    Iron-sulfides were observed in deposits collected on a probe inserted at the top of the furnace of a coal-fired power station in Denmark. The chemical composition of the iron-sulfides is equivalent to pyrrhotite (FeS). The pyrrhotites are present as crystals and, based on the shape of the crystals......, it was deduced that they were not deposited but instead grew within the deposit. The presence of unburned char particles within the deposits supports the concept that a reducing environment existed in the deposits. Two processes are proposed for explaining the existence of pyrrhotite crystals within a deposit...

  19. Probing the water interactions in clay

    Energy Technology Data Exchange (ETDEWEB)

    Powell, D.H. [Lausanne Univ., Lausanne (Switzerland); Fischer, H.E. [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France); Skipper, N.T. [Univ. College, London (United Kingdom)

    1999-11-01

    Clays, the microscopic mineral fraction of soils, are probably the most important substrate for interactions between water, the mineral world and the biosphere. A knowledge of the structuring of water and hydrated metal ions near clays surfaces is of importance in environmental science, including toxic and radioactive waste disposal, and in the industrial application of clays. The smectite clays, with their large hydrated internal surface areas represent excellent model systems for the interactions of aqueous phases with solid surface. We present the results of neutron diffraction experiments using isotopic substitutions to probe the structure in the aqueous interlayer region of Li-montmorillonite. (authors) 6 refs., 3 figs.

  20. Human probing behavior of Aedes aegypti when infected with a life-shortening strain of Wolbachia.

    Directory of Open Access Journals (Sweden)

    Luciano A Moreira

    Full Text Available BACKGROUND: Mosquitoes are vectors of many serious pathogens in tropical and sub-tropical countries. Current control strategies almost entirely rely upon insecticides, which increasingly face the problems of high cost, increasing mosquito resistance and negative effects on non-target organisms. Alternative strategies include the proposed use of inherited life-shortening agents, such as the Wolbachia bacterium. By shortening mosquito vector lifespan, Wolbachia could potentially reduce the vectorial capacity of mosquito populations. We have recently been able to stably transinfect Aedes aegypti mosquitoes with the life-shortening Wolbachia strain wMelPop, and are assessing various aspects of its interaction with the mosquito host to determine its likely impact on pathogen transmission as well as its potential ability to invade A. aegypti populations. METHODOLOGY/PRINCIPAL FINDINGS: Here we have examined the probing behavior of Wolbachia-infected mosquitoes in an attempt to understand both the broader impact of Wolbachia infection on mosquito biology and, in particular, vectorial capacity. The probing behavior of wMelPop-infected mosquitoes at four adult ages was examined and compared to uninfected controls during video-recorded feeding trials on a human hand. Wolbachia-positive insects, from 15 days of age, showed a drastic increase in the time spent pre-probing and probing relative to uninfected controls. Two other important features for blood feeding, saliva volume and apyrase content of saliva, were also studied. CONCLUSIONS/SIGNIFICANCE: As A. aegypti infected with wMelPop age, they show increasing difficulty in completing the process of blood feeding effectively and efficiently. Wolbachia-infected mosquitoes on average produced smaller volumes of saliva that still contained the same amount of apyrase activity as uninfected mosquitoes. These effects on blood feeding behavior may reduce vectorial capacity and point to underlying physiological

  1. Multi-point probe for testing electrical properties and a method of producing a multi-point probe

    DEFF Research Database (Denmark)

    2011-01-01

    A multi-point probe for testing electrical properties of a number of specific locations of a test sample comprises a supporting body defining a first surface, a first multitude of conductive probe arms (101-101'''), each of the probe arms defining a proximal end and a distal end. The probe arms...... are connected to the supporting body (105) at the proximal ends, and the distal ends are freely extending from the supporting body, giving individually flexible motion to the probe arms. Each of the probe arms defines a maximum width perpendicular to its perpendicular bisector and parallel with its line...... of contact with the supporting body, and a maximum thickness perpendicular to its perpendicular bisector and its line of contact with the supporting body. Each of the probe arms has a specific area or point of contact (111-111''') at its distal end for contacting a specific location among the number...

  2. Policies for Probe-Wear Leveling in MEMS-Based Storage Devices

    NARCIS (Netherlands)

    Khatib, M.G.; Hartel, P.H.

    2009-01-01

    Probes (or read/write heads) in MEMS-based storage devices are susceptible to wear. We study probe wear, and analyze the causes of probe uneven wear. We show that under real-world traces some probes can wear one order of magnitude faster than other probes leading to premature expiry of some probes.

  3. Fatigue Life Analysis of Cantilever Probe on Wafer Test

    Directory of Open Access Journals (Sweden)

    Hsiao Te-Ching

    2016-01-01

    Full Text Available This research utilizes the finite element analysis software (ANSYS to stimulate the different probe material quality (tungsten, SUS304 stainless steel, SUS316L stainless steel and SKD11 tool steel, respectively during wafer tests. Under a room temperature of (25°C, the stress and fatigue life (cycles of probing test of the cantilever probe were measured with an OverDriver (OD of 20µm, 40µm, 50µm, 60µm and 80µm, respectively. First, to obtain the magnitude of pinpoint shift of the probe under wafer test and the OverDriver is 50µm. And, calculate the fatigue life of the probe. Then, a probe model with the same characteristics as the experiment is created and the probe fatigue life analyzed with the ANSYS. After the reliability of the model is ascertained, the wafer tests of different probe materials are stimulated under different OverDriver circumstances to calculate its stress and fatigue life. The results indicate that the greatest stress measured during the wafer test of the tungsten, SUS304 stainless steel, SUS316L stainless steel and SKD11 tool steel cantilever probe are all smaller than the yield strength, and the fatigue life could reach over one hundred K cycles. When catalogued by the cantilever probe fatigue life during one hundred K cycles, the life span, in order, is tungsten < SUS316L stainless steel < SUS304 stainless steel < SKD11 tool steel.

  4. Gateways to clinical trials.

    Science.gov (United States)

    Bayés, M; Rabasseda, X; Prous, J R

    2005-04-01

    Gateways to Clinical Trials is a guide to the most recent clinical trials in current literature and congresses. The data in the following tables has been retrieved from the Clinical Trials Knowledge Area of Prous Science Integrity, the drug discovery and development portal, http://integrity. prous.com. This issue focuses on the following selection of drugs: ABX-IL-8, Acclaim, adalimumab, AGI-1067, alagebrium chloride, alemtuzumab, Alequel, Androgel, anti-IL-12 MAb, AOD-9604, aripiprazole, atomoxetine hydrochloride; Biphasic insulin aspart, bosentan, botulinum toxin type B, bovine lactoferrin, brivudine; Cantuzumab mertansine, CB-1954, CDB-4124, CEA-TRICOM, choriogonadotropin alfa, cilansetron, CpG-10101, CpG-7909, CTL-102, CTL-102/CB-1954; DAC:GRF, darbepoetin alfa, davanat-1, decitabine, del-1 Genemedicine, dexanabinol, dextofisopam, dnaJP1, dronedarone hydrochloride, dutasteride; Ecogramostim, eletriptan, emtricitabine, EPI-hNE-4, eplerenone, eplivanserin fumarate, erlotinib hydrochloride, ertapenem sodium, escitalopram oxalate, esomeprazole magnesium, etoricoxib, ezetimibe; Falecalcitriol, fingolimod hydrochloride; Gepirone hydrochloride; HBV-ISS, HSV-2 theracine, human insulin; Imatinib mesylate, Indiplon, insulin glargine, ISAtx-247; L612 HuMAb, levodopa/carbidopa/entacapone, lidocaine/prilocaine, LL-2113AD, lucinactant, LY-156735; Meclinertant, metelimumab, morphine hydrochloride, morphine-6-glucuronide; Natalizumab, nimotuzumab, NX-1207, NYVAC-HIV C; Omalizumab, onercept, osanetant; PABA, palosuran sulfate, parathyroid hormone (human recombinant), parecoxib sodium, PBI-1402, PCK-3145, peginterferon alfa-2a, peginterferon alfa-2b, peginterferon alfa-2b/ribavirin, pemetrexed disodium, pimecrolimus, PINC, pregabalin; Ramelteon, rasagiline mesilate, rasburicase, rimonabant hydrochloride, RO-0098557, rofecoxib, rosiglitazone maleate/metformin hydrochloride; Safinamide mesilate, SHL-749, sitaxsentan sodium, sparfosic acid, SprayGel, squalamine, St. John's Wort

  5. The ONTARGET trial programme

    DEFF Research Database (Denmark)

    Unger, Thomas; Kintscher, Ulrich; Kappert, Kai;

    2009-01-01

    The ONTARGET trial programme tested the effects of the angiotensin AT1 receptor blocker (ARB), telmisartan, alone or in combination with the angiotensin converting enzyme (ACE) inhibitor, ramipril, in more than 25.000 patients at high cardiovascular risk including diabetes on a combined endpoint ....... Telmisartan thus proved to be the first and so far the only representative of the ARB class that can be used as an alternative to the "gold standard" ACE-inhibitor, ramipril, in patients at high cardiovascular risk with or without hypertension. © 2009 Bentham Science Publishers Ltd....

  6. Mining information from atom probe data.

    Science.gov (United States)

    Cairney, Julie M; Rajan, Krishna; Haley, Daniel; Gault, Baptiste; Bagot, Paul A J; Choi, Pyuck-Pa; Felfer, Peter J; Ringer, Simon P; Marceau, Ross K W; Moody, Michael P

    2015-12-01

    Whilst atom probe tomography (APT) is a powerful technique with the capacity to gather information containing hundreds of millions of atoms from a single specimen, the ability to effectively use this information creates significant challenges. The main technological bottleneck lies in handling the extremely large amounts of data on spatial-chemical correlations, as well as developing new quantitative computational foundations for image reconstruction that target critical and transformative problems in materials science. The power to explore materials at the atomic scale with the extraordinary level of sensitivity of detection offered by atom probe tomography has not been not fully harnessed due to the challenges of dealing with missing, sparse and often noisy data. Hence there is a profound need to couple the analytical tools to deal with the data challenges with the experimental issues associated with this instrument. In this paper we provide a summary of some key issues associated with the challenges, and solutions to extract or "mine" fundamental materials science information from that data.

  7. Electric probe for spin transition and fluctuation

    Science.gov (United States)

    Qiu, Zhiyong; Li, Jia; Hou, Dazhi; Arenholz, Elke; N'diaye, Alpha T.; Tan, Ali; Uchida, Ken-Ichi; Sato, Koji; Tserkovnyak, Yaroslov; Qiu, Z. Q.; Saitoh, Eiji

    Spin fluctuation and transition have always been one of central topics of magnetism and condense matter science. To probe them, neutron scatterings have been used as powerful tools. A part of neutrons injected into a sample is scattered by spin fluctuation inside the sample. This process transcribes the spin fluctuation onto scattering intensity, which is commonly represented by dynamical magnetic susceptibility of the sample and is maximized at magnetic phase transitions. Importantly, a neutron carries spin without electric charge, and it thus can bring spin into a sample without being disturbed by electric energy: an advantage of neutrons, although large facilities such as a nuclear reactor is necessary. Here we show that spin pumping, frequently used in nanoscale spintronic devices, provides a desktop micro probe for spin fluctuation and transition; not only a neutron beam, spin current is also a flux of spin without an electric charge and its transport reflects spin fluctuation in a sample. We demonstrate detection of anti-ferromagnetic transition in ultra-thin CoO films via frequency dependent spin-current transmission measurements.

  8. Tests of Hadronic Probes of GT Strength

    CERN Multimedia

    2002-01-01

    There are many important problems where one wishes to know the distribution of Gamow-Teller (GT) strength in circumstances where it cannot be measured directly (for example, because of energy-release limitations). Then one must rely on hadronic probes to infer the GT strength. It is therefore essential to test these probes as extensively as possible. The isospin-analog transitions in $^{37}$Ca $\\beta^{+}$ -decay and $^{37}$Cl$(p, n)$ provide an excellent ground for such a test. Recent $^{37}$Cl$ (p, n) $ studies, while qualitatively in agreement with our previous ISOLDE work on $^{37}$Ca $\\beta^{+} $ -decay, show quantitative discrepancies that appear to grow as the excitation energy in the residual nuclei increases. Because of the bulk of the GT strengh appears at these high excitation energies, it is important to extend the $\\beta$-decay data to even higher excitation energies where, because of rapidly diminishing phase-space, strong GT transitions correspond to very weak $\\beta$ -branches. We propose to do...

  9. An approach to directly probe simultaneity

    Science.gov (United States)

    Kipreos, Edward T.; Balachandran, Riju S.

    2016-08-01

    The theory of special relativity derives from the Lorentz transformation. The Lorentz transformation implies differential simultaneity and light speed isotropy. Experiments to probe differential simultaneity should be able to distinguish the Lorentz transformation from a kinematically-similar alternate transformation that predicts absolute simultaneity, the absolute Lorentz transformation. Here, we describe how published optical tests of light speed isotropy/anisotropy cannot distinguish between the two transformations. We show that the shared equations of the two transformations, from the perspective of the “stationary” observer, are sufficient to predict null results in optical resonator experiments and in tests of frequency changes in one-way light paths. In an influential 1910 exposition on differential simultaneity, Comstock described how a “stationary” observer would observe different clock readings for spatially-separated “moving” clocks. The difference in clock readings is an integral aspect of differential simultaneity. We derive the equation for the difference in clock readings and show that it is equivalent to the Sagnac correction that describes light speed anisotropies in satellite communications. We describe an experimental strategy that can measure the differences in spatially-separated clock times to allow a direct probe of the nature of simultaneity.

  10. Mapping interfacial excess in atom probe data

    Energy Technology Data Exchange (ETDEWEB)

    Felfer, Peter, E-mail: peter.felfer@sydney.edu.au [School of Aerospace Mechanical and Mechatronic Engineering, The University of Sydney (Australia); Australian Centre for Microscopy and Microanalysis, The University of Sydney (Australia); Scherrer, Barbara [Australian Centre for Microscopy and Microanalysis, The University of Sydney (Australia); Eidgenossische Technische Hochschule Zürich (Switzerland); Demeulemeester, Jelle [Imec vzw, Kapeldreef 75, Heverlee 3001 (Belgium); Vandervorst, Wilfried [Imec vzw, Kapeldreef 75, Heverlee 3001 (Belgium); Instituut voor Kern- en Stralingsfysica, KU Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium); Cairney, Julie M. [School of Aerospace Mechanical and Mechatronic Engineering, The University of Sydney (Australia); Australian Centre for Microscopy and Microanalysis, The University of Sydney (Australia)

    2015-12-15

    Using modern wide-angle atom probes, it is possible to acquire atomic scale 3D data containing 1000 s of nm{sup 2} of interfaces. It is therefore possible to probe the distribution of segregated species across these interfaces. Here, we present techniques that allow the production of models for interfacial excess (IE) mapping and discuss the underlying considerations and sampling statistics. We also show, how the same principles can be used to achieve thickness mapping of thin films. We demonstrate the effectiveness on example applications, including the analysis of segregation to a phase boundary in stainless steel, segregation to a metal–ceramic interface and the assessment of thickness variations of the gate oxide in a fin-FET. - Highlights: • Using computational geometry, interfacial excess can be mapped for various features in APT. • Suitable analysis models can be created by combining manual modelling and mesh generation algorithms. • Thin film thickness can be mapped with high accuracy using this technique.

  11. Probing crunching AdS cosmologies

    Science.gov (United States)

    Kumar, S. Prem; Vaganov, Vladislav

    2016-02-01

    Holographic gravity duals of deformations of CFTs formulated on de Sitter spacetime contain FRW geometries behind a horizon, with cosmological big crunch singularities. Using a specific analytically tractable solution within a particular single scalar truncation of {N}=8 supergravity on AdS4, we first probe such crunching cosmologies with spacelike radial geodesics that compute spatially antipodal correlators of large dimension boundary operators. At late times, the geodesics lie on the FRW slice of maximal expansion behind the horizon. The late time two-point functions factorise, and when transformed to the Einstein static universe, they exhibit a temporal non-analyticity determined by the maximal value of the scale factor ã max. Radial geodesics connecting antipodal points necessarily have de Sitter energy Ɛ ≲ ã max, while geodesics with Ɛ > ã max terminate at the crunch, the two categories of geodesics being separated by the maximal expansion slice. The spacelike crunch singularity is curved "outward" in the Penrose diagram for the deformed AdS backgrounds, and thus geodesic limits of the antipodal correlators do not directly probe the crunch. Beyond the geodesic limit, we point out that the scalar wave equation, analytically continued into the FRW patch, has a potential which is singular at the crunch along with complex WKB turning points in the vicinity of the FRW crunch. We then argue that the frequency space Green's function has a branch point determined by ã max which corresponds to the lowest quasinormal frequency.

  12. Scanning Probe Microscope-Based Fluid Dispensing

    Directory of Open Access Journals (Sweden)

    Murali Krishna Ghatkesar

    2014-10-01

    Full Text Available Advances in micro and nano fabrication technologies have enabled fabrication of smaller and more sensitive devices for applications not only in solid-state physics but also in medicine and biology. The demand for devices that can precisely transport material, specifically fluids are continuously increasing. Therefore, integration of various technologies with numerous functionalities in one single device is important. Scanning probe microscope (SPM is one such device that has evolved from atomic force microscope for imaging to a variety of microscopes by integrating different physical and chemical mechanisms. In this article, we review a particular class of SPM devices that are suited for fluid dispensing. We review their fabrication methods, fluid-pumping mechanisms, real-time monitoring of dispensing, physics of dispensing, and droplet characterization. Some of the examples where these probes have already been applied are also described. Finally, we conclude with an outlook and future scope for these devices where femtolitre or smaller volumes of liquid handling are needed.

  13. A quirky probe of neutral naturalness

    Science.gov (United States)

    Chacko, Zackaria; Curtin, David; Verhaaren, Christopher B.

    2016-07-01

    We consider the signals arising from top partner pair production at the LHC as a probe of theories of neutral naturalness. We focus on scenarios in which top partners carry electroweak charges, such as folded supersymmetry or the quirky little Higgs. In this class of theories the top partners are pair produced as quirky bound states, since they are charged under a mirror color group whose lightest states are hidden glueballs. The quirks promptly de-excite and annihilate into glueballs, which decay back to Standard Model fermions via Higgs mixing. This can give rise to spectacular signatures at the LHC, such displaced decays, or high-multiplicity prompt production of many hard b ¯b or τ+τ- pairs. We show that signals arising from top partner pair production constitute the primary discovery channel for this class of theories in most regions of parameter space, and might provide the only experimental probe of scenarios with sub-cm glueball decay lengths. The measurement of top partner masses and couplings, which could be used to test the neutral naturalness mechanism directly, is also a tantalizing possibility.

  14. Microfluidics for Positron Emission Tomography Probe Development

    Directory of Open Access Journals (Sweden)

    Ming-Wei Wang

    2010-07-01

    Full Text Available Owing to increased needs for positron emission tomography (PET, high demands for a wide variety of radiolabeled compounds will have to be met by exploiting novel radiochemistry and engineering technologies to improve the production and development of PET probes. The application of microfluidic reactors to perform radiosyntheses is currently attracting a great deal of interest because of their potential to deliver many advantages over conventional labeling systems. Microfluidics-based radiochemistry can lead to the use of smaller quantities of precursors, accelerated reaction rates, and easier purification processes with greater yield and higher specific activity of desired probes. Several proof-of-principle examples along with the basics of device architecture and operation and the potential limitations of each design are discussed. Along with the concept of radioisotope distribution from centralized cyclotron facilities to individual imaging centers and laboratories (“decentralized model”, an easy-to-use, stand-alone, flexible, fully automated, radiochemical microfluidic platform can provide simpler and more cost-effective procedures for molecular imaging using PET.

  15. Results from the Wilkinson Microwave Anisotropy Probe

    Science.gov (United States)

    Komatsu, E.; Bennett, Charles L.; Komatsu, Eiichiro

    2015-01-01

    The Wilkinson Microwave Anisotropy Probe (WMAP) mapped the distribution of temperature and polarization over the entire sky in five microwave frequency bands. These full-sky maps were used to obtain measurements of temperature and polarization anisotropy of the cosmic microwave background with the unprecedented accuracy and precision. The analysis of two-point correlation functions of temperature and polarization data gives determinations of the fundamental cosmological parameters such as the age and composition of the universe, as well as the key parameters describing the physics of inflation, which is further constrained by three-point correlation functions. WMAP observations alone reduced the flat ? cold dark matter (Lambda Cold Dark Matter) cosmological model (six) parameter volume by a factor of > 68, 000 compared with pre-WMAP measurements. The WMAP observations (sometimes in combination with other astrophysical probes) convincingly show the existence of non-baryonic dark matter, the cosmic neutrino background, flatness of spatial geometry of the universe, a deviation from a scale-invariant spectrum of initial scalar fluctuations, and that the current universe is undergoing an accelerated expansion. The WMAP observations provide the strongest ever support for inflation; namely, the structures we see in the universe originate from quantum fluctuations generated during inflation.

  16. Novel Probes of Gravity and Dark Energy

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Bhuvnesh; et al.

    2013-09-20

    The discovery of cosmic acceleration has stimulated theorists to consider dark energy or modifications to Einstein's General Relativity as possible explanations. The last decade has seen advances in theories that go beyond smooth dark energy -- modified gravity and interactions of dark energy. While the theoretical terrain is being actively explored, the generic presence of fifth forces and dark sector couplings suggests a set of distinct observational signatures. This report focuses on observations that differ from the conventional probes that map the expansion history or large-scale structure. Examples of such novel probes are: detection of scalar fields via lab experiments, tests of modified gravity using stars and galaxies in the nearby universe, comparison of lensing and dynamical masses of galaxies and clusters, and the measurements of fundamental constants at high redshift. The observational expertise involved is very broad as it spans laboratory experiments, high resolution astronomical imaging and spectroscopy and radio observations. In the coming decade, searches for these effects have the potential for discovering fundamental new physics. We discuss how the searches can be carried out using experiments that are already under way or with modest adaptations of existing telescopes or planned experiments. The accompanying paper on the Growth of Cosmic Structure describes complementary tests of gravity with observations of large-scale structure.

  17. Design considerations for miniaturized optical neural probes

    Science.gov (United States)

    Rudmann, Linda; Ordonez, Juan S.; Stieglitz, Thomas

    2016-03-01

    Neural probes are designed to selectively record from or stimulate nerve cells. In optogenetics it is desirable to build miniaturized and long-term stable optical neural probes, in which the light sources can be directly and chronically implanted into the animals to allow free movement and behavior. Because of the size and the beam shape of the available light sources, it is difficult to target single cells as well as spatially localized networks. We therefore investigated design considerations for packages, which encapsulate the light source hermetically and have integrated hemispherical lens structures that enable to focus the light onto the desired region, by optical simulations. Integration of a biconvex lens into the package lid (diameter = 300 μm, material: silicon carbide) increased the averaged absolute irradiance ηA by 298 % compared to a system without a lens and had a spot size of around 120 μm. Solely integrating a plano-convex lens (same diameter and material) results in an ηA of up to 227 %.

  18. Single optical fiber probe for optogenetics

    Science.gov (United States)

    Falk, Ryan; Habibi, Mohammad; Pashaie, Ramin

    2012-03-01

    With the advent of optogenetics, all optical control and visualization of the activity of specific cell types is possible. We have developed a fiber optic based probe to control/visualize neuronal activity deep in the brain of awake behaving animals. In this design a thin multimode optical fiber serves as the head of the probe to be inserted into the brain. This fiber is used to deliver excitation/stimulation optical pulses and guide a sample of the emission signal back to a detector. The major trade off in the design of such a system is to decrease the size of the fiber and intensity of input light to minimize physical damage and to avoid photobleaching/phototoxicity but to keep the S/N reasonably high. Here the excitation light, and the associated emission signal, are frequency modulated. Then the output of the detector is passed through a time-lens which compresses the distributed energy of the emission signal and maximizes the instantaneous S/N. By measuring the statistics of the noise, the structure of the time lens can be designed to achieve the global optimum of S/N. Theoretically, the temporal resolution of the system is only limited by the time lens diffraction limit. By adding a second detector, we eliminated the effect of input light fluctuations, imperfection of the optical filters, and back-reflection of the excitation light. We have also designed fibers and micro mechanical assemblies for distributed delivery and detection of light.

  19. NMR probe for dynamic-angle spinning

    Science.gov (United States)

    Mueller, K. T.; Chingas, G. C.; Pines, A.

    1991-06-01

    We describe the design of a probe for dynamic-angle spinning (DAS) NMR experiments, comprised of a spinning cylindrical sample holder whose axis may be reoriented rapidly between discrete directions within the bore of a superconducting magnet. This allows the refocusing of nuclear spin magnetization that evolves under anisotropic interactions such as chemical shift anisotropy and quadrupolar coupling, providing high resolution NMR spectra for quadrupolar nuclei in solid materials. The probe includes an axial air delivery system to bearing and drive jets which support and spin a rotor containing the sample. Axis reorientation is accomplished with a pulley attached to the probehead and coupled to a stepping motor outside of the magnet. The choice of motor and gear ratio is based on an analysis of the moments of inertia of the motor and load, the desired angular resolution, and simplicity of design. Control of angular accuracy and precision are discussed, as well as the efficiency of radiofrequency irradiation and detection. High resolution DAS spectra of oxygen-17 and aluminum-27 nuclei in polycrystalline minerals illustrate the experimental capabilities.

  20. Invited Review Article: Pump-probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Martin C., E-mail: Martin.Fischer@duke.edu; Wilson, Jesse W.; Robles, Francisco E. [Department of Chemistry, Duke University, Durham, North Carolina 27708 (United States); Warren, Warren S. [Departments of Chemistry, Biomedical Engineering, Physics, and Radiology, Duke University, Durham, North Carolina 27708 (United States)

    2016-03-15

    Multiphoton microscopy has rapidly gained popularity in biomedical imaging and materials science because of its ability to provide three-dimensional images at high spatial and temporal resolution even in optically scattering environments. Currently the majority of commercial and home-built devices are based on two-photon fluorescence and harmonic generation contrast. These two contrast mechanisms are relatively easy to measure but can access only a limited range of endogenous targets. Recent developments in fast laser pulse generation, pulse shaping, and detection technology have made accessible a wide range of optical contrasts that utilize multiple pulses of different colors. Molecular excitation with multiple pulses offers a large number of adjustable parameters. For example, in two-pulse pump-probe microscopy, one can vary the wavelength of each excitation pulse, the detection wavelength, the timing between the excitation pulses, and the detection gating window after excitation. Such a large parameter space can provide much greater molecular specificity than existing single-color techniques and allow for structural and functional imaging without the need for exogenous dyes and labels, which might interfere with the system under study. In this review, we provide a tutorial overview, covering principles of pump-probe microscopy and experimental setup, challenges associated with signal detection and data processing, and an overview of applications.

  1. Formative Assessment Probes: Talk Moves. A Formative Assessment Strategy for Fostering Productive Probe Discussions

    Science.gov (United States)

    Keeley, Page

    2016-01-01

    Formative assessment probes can be used to foster productive science discussions in which students make their thinking visible to themselves, their peers, and the teacher. During these discussions, there is an exchange between the teacher and students that encourages exploratory thinking, supports careful listening to others' ideas, asks for…

  2. Probing ultrafast dynamics of condensed matter with pump and probe experiments with X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Giles, Carlos; Celestre, Rafael; Tasca, Kelin R.; Vescovi, Rafael; Faria, Guilherme; Dias, Carlos S.; Tomm, Natasha; Cordeiro, Cristiano M.B. [Universidade Estadual de Campinas (IFGW/UNICAMP), SP (Brazil). Inst. de Fisica Gleb Wataghin; Silva, Rene Nome [Universidade Estadual de Campinas (IQ/UNICAMP), SP (Brazil). Inst. de Quimica

    2012-07-01

    Full text: In this presentation we will describe recent advances in the route to start ultrafast studies with X-rays in Brazil. From one side pump and probe experiments using synchrotron radiation facilities will be described, showing how the thermal expansion of an invar alloy is not occurring at the picosecond time scales after heating the sample with a femtosecond infrared laser pulse. We will also describe the experimental setup at the LNLS in Campinas were we probe the fast response of a piezoelectric material to a 1 ns electric pulse recorded by a pump and probe X-ray diffraction experiment at the XRD2 LNLS beamline. We will also present the first results of the production of sub-picosecond X-ray pulses using an amplified infrared laser at the Ultrafast Laboratory of DEQ/IFGW. The instrumentation developed at UNICAMP together with the first setup for a pump and probe experiment will be presented. Characteristic radiation of various targets (TiK{alpha}, FeK{alpha}, CuK{alpha}) have been measured at a repetition rate of 1 kHz showing unambiguously our capability of producing a pulsed X-ray source for time resolved x-ray diffraction experiments. Experiments to measure the pulse width of the X-ray radiation are under development and the latest results will be presented. All these efforts open the path to the nucleation of a research group in ultrafast studies using X-rays in Brazil. (author)

  3. COTS MEMS Flow-Measurement Probes

    Science.gov (United States)

    Redding, Chip; Smith, Floyd A.; Blank, Greg; Cruzan, Charles

    2004-01-01

    As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at Glenn Research Center have been fabricating packaging components and assembling a set of unique probes that contain commercial off-the-shelf (COTS) microelectromechanical systems (MEMS) sensor chips. MEMS sensor chips offer some compelling advantages over standard macroscopic measurement devices. MEMS sensor technology has matured through mass production and use in the automotive and aircraft industries. At present, MEMS are the devices of choice for sensors in such applications as tire-pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Compactness, minimality of power demand, rugged construction, and moderate cost all contribute to making MEMS sensors attractive for instrumentation for future research. Conventional macroscopic flow-measurement instrumentation includes tubes buried beneath the aerodynamic surfaces of wind-tunnel models or in wind-tunnel walls. Pressure is introduced at the opening of each such tube. The pressure must then travel along the tube before reaching a transducer that generates an electronic signal. The lengths of such tubes typically range from 20 ft (approx.= 6 m) to hundreds of feet (of the order of 100 m). The propagation of pressure signals in the tubes damps the signals considerably and makes it necessary to delay measurements until after test rigs have reached steady-state operation. In contrast, a MEMS pressure sensor that generates electronic output can take readings continuously under dynamic conditions in nearly real time. In order to use stainless-steel tubing for pressure measurements, it is necessary to clean many tubes, cut them to length, carefully install them, delicately deburr them, and splice them. A cluster of a few hundred 1/16-in.- (approx.=1.6-mm-) diameter tubes (such clusters are common in research testing facilities) can be several inches (of the order of 10

  4. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis.

    Science.gov (United States)

    Ferguson, Stephen J; Visser, Judith M A; Polikeit, Anne

    2006-02-01

    Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (Pcreep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.

  5. [Critical reading of clinical trials].

    Science.gov (United States)

    Aptel, F; Cucherat, M; Blumen-Ohana, E; Denis, P

    2011-12-01

    Clinical trials are playing an increasingly crucial role in modern evidence based medicine, allowing for rigorous scientific evaluation of treatment strategies and validation of patient care. The results of clinical trials often form the rational basis from which physicians draw information used to adapt their therapeutic practices. Critical reading and analysis of trials involves the assessment of whether the available data provide enough credible evidence that the treatment will result in a clinically significant and relevant improvement. Evaluating the quality of a clinical trial is a process that draws upon sometimes complex methodological and statistical concepts, with which the reader should nonetheless be familiar in order to come to impartial conclusions regarding the raw data presented in the clinical trials. The goal of the current article is to review the methodological and statistical concepts required for the design and interpretation of clinical trials, so as to allow for a critical analysis of publications or presentations of clinical trials. The first section describes the major methodological principles of clinical trial design required for a rigorous evaluation of the treatment benefit, as well as the various pitfalls or biases that could lead to erroneous conclusions. The second section briefly describes the main statistical tests used in clinical trials, as well as certain situations that may increase the risk of false positive findings (type 1 error), such as multiple, subgroup, intermediate and non-inferiority analysis. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  6. What Are Clinical Trial Phases?

    Medline Plus

    Full Text Available ... Phases of Clinical Trials Cancer Treatment Types of Cancer Treatment Surgery Radiation Therapy Chemotherapy Immunotherapy Targeted Therapy Hormone Therapy Stem Cell Transplant Precision ...

  7. Birefringence effects of short probe pulses of electromagnetically induced transparency

    Science.gov (United States)

    Parshkov, Oleg M.; Kochetkova, Anastasia E.; Budyak, Victoria V.

    2016-04-01

    The numerical simulation results of radiations evolution in the presence of electromagnetically induced transparency for J=0-->J=1-->J=2 scheme of degenerate quantum transitions are presented. The pulse regime of wave interaction with Doppler broadening spectral lines was investigated. It was indicated that when the control field is linear polarized, the input circular polarized probe pulse breaks up in the medium into pulses with mutually perpendicular linear polarizations. Polarization direction of one of these pulses coincides with the polarization direction of control fields. The distance, which probe pulse passes in the medium to its full separation, decreases, when input probe pulse duration or control field intensity decreases. The input probe pulse intensity variation almost does not influence separation distance and speed of the linear polarized probe pulses in the medium. The effects, described above, may be interpreted as the birefringence effects of electromagnetically induced transparency in the case of short probe pulse.

  8. A single probe for imaging photons, electrons and physical forces

    Science.gov (United States)

    Pilet, Nicolas; Lisunova, Yuliya; Lamattina, Fabio; Stevenson, Stephanie E.; Pigozzi, Giancarlo; Paruch, Patrycja; Fink, Rainer H.; Hug, Hans J.; Quitmann, Christoph; Raabe, Joerg

    2016-06-01

    The combination of complementary measurement techniques has become a frequent approach to improve scientific knowledge. Pairing of the high lateral resolution scanning force microscopy (SFM) with the spectroscopic information accessible through scanning transmission soft x-ray microscopy (STXM) permits assessing physical and chemical material properties with high spatial resolution. We present progress from the NanoXAS instrument towards using an SFM probe as an x-ray detector for STXM measurements. Just by the variation of one parameter, the SFM probe can be utilised to detect either sample photo-emitted electrons or transmitted photons. This allows the use of a single probe to detect electrons, photons and physical forces of interest. We also show recent progress and demonstrate the current limitations of using a high aspect ratio coaxial SFM probe to detect photo-emitted electrons with very high lateral resolution. Novel probe designs are proposed to further progress in using an SFM probe as a STXM detector.

  9. Can quantum probes satisfy the weak equivalence principle?

    Energy Technology Data Exchange (ETDEWEB)

    Seveso, Luigi, E-mail: luigi.seveso@unimi.it [Quantum Technology Lab, Dipartimento di Fisica, Università degli Studi di Milano, I-20133 Milano (Italy); Paris, Matteo G.A. [Quantum Technology Lab, Dipartimento di Fisica, Università degli Studi di Milano, I-20133 Milano (Italy); INFN, Sezione di Milano, I-20133 Milano (Italy)

    2017-05-15

    We address the question whether quantum probes in a gravitational field can be considered as test particles obeying the weak equivalence principle (WEP). A formulation of the WEP is proposed which applies also in the quantum regime, while maintaining the physical content of its classical counterpart. Such formulation requires the introduction of a gravitational field not to modify the Fisher information about the mass of a freely-falling probe, extractable through measurements of its position. We discover that, while in a uniform field quantum probes satisfy our formulation of the WEP exactly, gravity gradients can encode nontrivial information about the particle’s mass in its wavefunction, leading to violations of the WEP. - Highlights: • Can quantum probes under gravity be approximated as test-bodies? • A formulation of the weak equivalence principle for quantum probes is proposed. • Quantum probes are found to violate it as a matter of principle.

  10. An improved probe noise approach for acoustic feedback cancellation

    DEFF Research Database (Denmark)

    Guo, Meng; Jensen, Søren Holdt; Jensen, Jesper

    2012-01-01

    -state error of the adaptive algorithm in a multiple-microphone and single-loudspeaker audio system. This is obtained through a specifically designed probe noise signal and a corresponding probe noise enhancement strategy. We show the effects of the proposed probe noise approach by deriving analytical......The perhaps most challenging problem in acoustic feedback cancellation using adaptive filters is the bias problem. It is well-known that a probe noise approach can effectively prevent this problem. However, when the probe noise must be inaudible and the steady-state error of the adaptive filter...... must be unchanged, this approach causes a significantly decreased convergence rate of the adaptive filter, and might thereby be less useful in practical applications. In this work, we propose a new probe noise approach which significantly increases the convergence rate while maintaining the steady...

  11. Micromachined hot-wire thermal conductivity probe for biomedical applications.

    Science.gov (United States)

    Yi, Ming; Panchawagh, Hrishikesh V; Podhajsky, Ronald J; Mahajan, Roop L

    2009-10-01

    This paper presents the design, fabrication, numerical simulation, and experimental validation of a micromachined probe that measures thermal conductivity of biological tissues. The probe consists of a pair of resistive line heating elements and resistance temperature detector sensors, which were fabricated by using planar photolithography on a glass substrate. The numerical analysis revealed that the thermal conductivity and diffusivity can be determined by the temperature response induced by the uniform heat flux in the heating elements. After calibrating the probe using a material (agar gel) of known thermal conductivity, the probe was deployed to calculate the thermal conductivity of Crisco. The measured value is in agreement with that determined by the macro-hot-wire probe method to within 3%. Finally, the micro thermal probe was used to investigate the change of thermal conductivity of pig liver before and after RF ablation treatment. The results show an increase in thermal conductivity of liver after the RF ablation.

  12. In Situ Atom Probe Deintercalation of Lithium-Manganese-Oxide.

    Science.gov (United States)

    Pfeiffer, Björn; Maier, Johannes; Arlt, Jonas; Nowak, Carsten

    2017-01-30

    Atom probe tomography is routinely used for the characterization of materials microstructures, usually assuming that the microstructure is unaltered by the analysis. When analyzing ionic conductors, however, gradients in the chemical potential and the electric field penetrating dielectric atom probe specimens can cause significant ionic mobility. Although ionic mobility is undesirable when aiming for materials characterization, it offers a strategy to manipulate materials directly in situ in the atom probe. Here, we present experimental results on the analysis of the ionic conductor lithium-manganese-oxide with different atom probe techniques. We demonstrate that, at a temperature of 30 K, characterization of the materials microstructure is possible without measurable Li mobility. Also, we show that at 298 K the material can be deintercalated, in situ in the atom probe, without changing the manganese-oxide host structure. Combining in situ atom probe deintercalation and subsequent conventional characterization, we demonstrate a new methodological approach to study ionic conductors even in early stages of deintercalation.

  13. 33S NMR cryogenic probe for taurine detection

    Science.gov (United States)

    Hobo, Fumio; Takahashi, Masato; Maeda, Hideaki

    2009-03-01

    With the goal of a S33 nuclear magnetic resonance (NMR) probe applicable to in vivo NMR on taurine-biological samples, we have developed the S33 NMR cryogenic probe, which is applicable to taurine solutions. The NMR sensitivity gain relative to a conventional broadband probe is as large as 3.5. This work suggests that improvements in the preamplifier could allow NMR measurements on 100 μM taurine solutions, which is the level of sensitivity necessary for biological samples.

  14. Dynamic Probing for Intrusion Detection under Resource Constraints

    Science.gov (United States)

    2013-06-01

    performance measure of regret, defined as the performance loss compared to that of a genie who knows the entire attack processes a priori and probes...performance as that of the omniscient genie . Index Terms—Intrusion detection, dynamic probing, non- stochastic multi-armed bandit, regret. I...dynamic probing strategy under the performance measure of regret, de ned as the performance loss compared to that of a genie who knows the entire attack

  15. Portable optical fiber probe for in vivo brain temperature measurements.

    Science.gov (United States)

    Musolino, Stefan; Schartner, Erik P; Tsiminis, Georgios; Salem, Abdallah; Monro, Tanya M; Hutchinson, Mark R

    2016-08-01

    This work reports on the development of an optical fiber based probe for in vivo measurements of brain temperature. By utilizing a thin layer of rare-earth doped tellurite glass on the tip of a conventional silica optical fiber a robust probe, suitable for long-term in vivo measurements of temperature can be fabricated. This probe can be interrogated using a portable optical measurement setup, allowing for measurements to be performed outside of standard optical laboratories.

  16. Automatic probe artifact detection in MRI-guided cryoablation

    Science.gov (United States)

    Liu, Xinyang; Tuncali, Kemal; Wells, William M.; Zientara, Gary P.

    2013-03-01

    Probe or needle artifact detection in 3D scans gives an approximate location for the tools inserted, and is thus crucial in assisting many image-guided procedures. Conventional needle localization algorithms often start with cropped images, where unwanted parts of raw scans are cropped either manually or by applying pre-defined masks. In cryoablation, however, the number of probes used, the placement and direction of probe insertion, and the portions of abdomen scanned differs significantly from case to case, and probes are often constantly being adjusted during the Probe Placement Phase. These features greatly reduce the practicality of approaches based on image cropping. In this work, we present a fully Automatic Probe Artifact Detection method, APAD, that works directly on uncropped raw MRI images, taken during the Probe Placement Phase in 3Tesla MRI-guided cryoablation. The key idea of our method is to first locate an initial 2D line strip within a slice of the MR image which approximates the position and direction of the 3D probes bundle, noting that cryoprobes or biopsy needles create a signal void (black) artifact in MRI with a bright cylindrical border. With the initial 2D line, standard approaches to detect line structures such as the 3D Hough Transform can be applied to quickly detect each probe's axis. By comparing with manually labeled probes, the analysis of 5 patient treatment cases of kidney cryoablation with varying probe placements demonstrates that our algorithm combined with standard 3D line detection is an accurate and robust method to detect probe artifacts.

  17. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    Science.gov (United States)

    Vo-Dinh, Tuan

    1995-01-01

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devises, in probe array devices.

  18. Single-nanoparticle-terminated tips for scanning probe microscopy.

    Science.gov (United States)

    Vakarelski, Ivan U; Higashitani, Ko

    2006-03-28

    We have developed a wet-chemistry procedure to attach a 10-40 nm colloidal gold nanoparticle to the top of a scanning probe microscopy (SPM) probe tip, making experiments of single nanoparticle interaction possible. This procedure of particle attachment is flexible and can be modified to attach nanoparticles of different kinds and sizes. The single-nanoparticle-terminated tips also have potential in various other applications, such as probes of enhanced sensitivity for optical and magnetic modes SPM.

  19. Cultivar identification in T. aestivum using highly polymorphic RFLP probes.

    Science.gov (United States)

    Vaccino, P; Accerbi, M; Corbellini, M

    1993-08-01

    Two probes, specific for HMW-glutenins and γ-gliadins have been used to identify 50 common wheat Italian cultivars, most of which are closely related, and four common wheat cultivars originating outside Italy. The probes revealed complex polymorphic patterns; three probe/enzyme combinations had the necessary sensitivity for the identification of all 54 cultivars. As already shown for potato and barley, the use of four-cutter restriction enzymes and polyacrylamide gels proved particularly useful for detecting polymorphism.

  20. Small Next-Generation Atmospheric Probe (SNAP) Concept

    Science.gov (United States)

    Sayanagi, K. M.; Dillman, R. A.; Simon, A. A.; Atkinson, D. H.; Wong, M. H.; Spilker, T. R.; Saikia, S.; Li, J.; Hope, D.

    2017-01-01

    We present the Small Next-Generation Atmospheric Probe (SNAP) as a secondary payload concept for future missions to giant planets. As a case study, we examine the advantages, cost and risk of adding SNAP to the future Uranus Orbiter and Probe flag-ship mission; in combination with the missions main probe, SNAP would perform atmospheric in-situ measurements at a second location.

  1. Evaluation of a dual-probe real time PCR system for detection of mandarin in commercial orange juice.

    Science.gov (United States)

    Pardo, Miguel Angel

    2015-04-01

    A dual-probe real time PCR assay, based on the simultaneous detection of two TaqMan® probes, was evaluated for the detection of mandarin in orange juice. A single conserved polymorphism, located at the 314 position of intron belongs to chloroplast trnL gene, was confirmed by sequencing in 30 mandarin, 28 orange cultivars and 13 hybrids. The assay was also successfully evaluated in a blind trial against analysing 60 samples from different industrial processes in different countries around the world. The detection limit of the assay was established in 1% presence of mandarin detectable in processed orange juice and with a 100% precision. The quantitative application of the assay on citrus mixtures was also investigated, pointing out that the number of chloroplast DNA copies is too variable for its possible use as quantitative analysis. This assay can be employed as a routine methodology to control the accidental mixing during industrial processes and to deter intentional fraud.

  2. Alternative mapping of probes to genes for Affymetrix chips

    Directory of Open Access Journals (Sweden)

    Friis-Hansen Lennart

    2004-08-01

    Full Text Available Abstract Background Short oligonucleotide arrays have several probes measuring the expression level of each target transcript. Therefore the selection of probes is a key component for the quality of measurements. However, once probes have been selected and synthesized on an array, it is still possible to re-evaluate the results using an updated mapping of probes to genes, taking into account the latest biological knowledge available. Methods We investigated how probes found on recent commercial microarrays for human genes (Affymetrix HG-U133A were matching a recent curated collection of human transcripts: the NCBI RefSeq database. We also built mappings and used them in place of the original probe to genes associations provided by the manufacturer of the arrays. Results In a large number of cases, 36%, the probes matching a reference sequence were consistent with the grouping of probes by the manufacturer of the chips. For the remaining cases there were discrepancies and we show how that can affect the analysis of data. Conclusions While the probes on Affymetrix arrays remain the same for several years, the biological knowledge concerning the genomic sequences evolves rapidly. Using up-to-date knowledge can apparently change the outcome of an analysis.

  3. Directly labeled fluorescent DNA probes for chromosome mapping

    Energy Technology Data Exchange (ETDEWEB)

    Marrone, B.L.; Deaven, L.L.; Chen, D.J.; Park, Min S.; MacInnes, M.A.; Salzman, G.C.; Yoshida, T.M.

    1995-12-31

    A new strategy is briefly described for employing nucleic acid probes that are directly labeled with fluorochromes in fluorescence in situ hybridization techniques. These probes will permit the detection, quantitation, and high-precision spatial analysis of multiple DNA sequences along a single chromosome using video-enhanced fluorescence microscopy and digital image processing and analysis. Potential advantages of direct labeled DNA probes for fluorescence in situ hybridization far surpass currently available, indirect DNA probe labeling techniques in ease of use, versatility, and increased signal- to-noise ratio.

  4. Complex quantum networks as structured environments: engineering and probing

    Science.gov (United States)

    Nokkala, Johannes; Galve, Fernando; Zambrini, Roberta; Maniscalco, Sabrina; Piilo, Jyrki

    2016-05-01

    We consider structured environments modeled by bosonic quantum networks and investigate the probing of their spectral density, structure, and topology. We demonstrate how to engineer a desired spectral density by changing the network structure. Our results show that the spectral density can be very accurately detected via a locally immersed quantum probe for virtually any network configuration. Moreover, we show how the entire network structure can be reconstructed by using a single quantum probe. We illustrate our findings presenting examples of spectral densities and topology probing for networks of genuine complexity.

  5. Field enhancement effect of metal probe in evanescent field

    Institute of Scientific and Technical Information of China (English)

    Xiaogang Hong; Wendong Xu; Xiaogang Li; Chengqiang Zhao; Xiaodong Tang

    2009-01-01

    Field enhancement effect of metal probe in evanescent field, induced by using a multi-layers structure for exciting surface plasmon resonance (SPR), is analyzed numerically by utilizing two-dimensional (2D) TM wave finite difference time-domain (FDTD) method. In this letter, we used a fundamental mode Gaussian beam to induce evanescent field, and calculated the electric intensity. The results show that compared with the nonmetal probe, the metal probe has a larger field enhancement effect, and its scattering wave induced by field enhancement has a bigger decay coefficient. The field enhancement effect should conclude that the metal probe has an important application in nanolithography.

  6. Probe Error Modeling Research Based on Bayesian Network

    Institute of Scientific and Technical Information of China (English)

    Wu Huaiqiang; Xing Zilong; Zhang Jian; Yan Yan

    2015-01-01

    Probe calibration is carried out under specific conditions; most of the error caused by the change of speed parameter has not been corrected. In order to reduce the measuring error influence on measurement accuracy, this article analyzes the relationship between speed parameter and probe error, and use Bayesian network to establish the model of probe error. Model takes account of prior knowledge and sample data, with the updating of data, which can reflect the change of the errors of the probe and constantly revised modeling results.

  7. Biocompatibility of a quad-shank neural probe

    Science.gov (United States)

    Tyson, Joel; Tran, Minhquan; Slaughter, Gymama

    2017-10-01

    Multichannel, flexible neural probes have been fabricated using standard CMOS techniques. The neural probe consists of four shanks with 16 recording sites each of approximately 290 μm2. The recording sites are created using gold rectangular pyramidal electrodes sandwiched between two polyimide dielectric layers. Windows in the first polyimide layer expose the electrode sites and bonding pads. The bonding pads and interconnect wires at the topmost section of the probe are soldered to tungsten wire followed by encapsulation with epoxy to protect the interconnections from contact with phosphate buffered saline solution. The electrode test impedance values at 1 kHz are on average 135 kΩ. Multi-walled carbon nanotubes (MWCNTs) were deposited on electrode sites resulting in a reduction of impedance at 1 kHz to 6.89 kΩ on average. Moreover, the cell viability and proliferation of the PC12 cells on the surface of the probe was investigated by trypan blue exclusion assay to evaluate biocompatibility of the probe material. The PC12 cells attached and grew on the surfaces of the probe with no significant effect on the cells' morphology and viability. The polyimide probe displayed a good cell viability and proliferation, making the polyimide attractive for potential candidate as probe materials in the fabrication of neural probes.

  8. Plasma probe characteristics in low density hydrogen pulsed plasmas

    CERN Document Server

    Astakhov, D I; Lee, C J; Ivanov, V V; Krivtsun, V M; Zotovich, A I; Zyryanov, S M; Lopaev, D V; Bijkerk, F

    2014-01-01

    Probe theories are only applicable in the regime where the probe's perturbation of the plasma can be neglected. However, it is not always possible to know, a priori, that a particular probe theory can be successfully applied, especially in low density plasmas. This is especially difficult in the case of transient, low density plasmas. Here, we applied probe diagnostics in combination with a 2D particle-in-cell model, to an experiment with a pulsed low density hydrogen plasma. The calculations took into account the full chamber geometry, including the plasma probe as an electrode in the chamber. It was found that the simulations reproduce the time evolution of the probe IV characteristics with good accuracy. The disagreement between the simulated and probe measured plasma density is attributed to the limited applicability of probe theory to measurements of low density pulsed plasmas. Indeed, in the case studied here, probe measurements would lead to a large overestimate of the plasma density. In contrast, the ...

  9. Preparation and Characterization of Fluorescence Probe from Assembly Hydroxyapatite Nanocomposite

    Directory of Open Access Journals (Sweden)

    Li Guang-Ming

    2010-01-01

    Full Text Available Abstract A new nanocomposite fluorescence probe with thioglycolic acid (TA functional layers embedded inside the hydroxyapatite nanoribbon spherulites has been synthesized. The fluorescence intensity of the novel probe is about 1.5–3.3-fold increase compared with the probe containing no TA. When used to detect cadmium ion, the most of original assembly nanoribbon spherulites structure in the novel probe is found to have been damaged to new flake structures. The mechanism of determining cadmium ion in alcohol solution has been studied. The present systematic study provides significant information on the effect of assembly nanostructure on the metal-enhanced fluorescence phenomenon.

  10. High Aspect-Ratio Neural Probes using Conventional Blade Dicing

    Science.gov (United States)

    Goncalves, S. B.; Ribeiro, J. F.; Silva, A. F.; Correia, J. H.

    2016-10-01

    Exploring deep neural circuits has triggered the development of long penetrating neural probes. Moreover, driven by brain displacement, the long neural probes require also a high aspect-ratio shafts design. In this paper, a simple and reproducible method of manufacturing long-shafts neural probes using blade dicing technology is presented. Results shows shafts up to 8 mm long and 200 µm wide, features competitive to the current state-of-art, being its outline simply accomplished by a single blade dicing program. Therefore, conventional blade dicing presents itself as a viable option to manufacture long neural probes.

  11. Designs of Langmuir probes for W7-X

    Energy Technology Data Exchange (ETDEWEB)

    Laube, Ralph, E-mail: ralph.laube@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstr. 1, D-17491 Greifswald (Germany); Laux, Michael; Ye, Min You [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstr. 1, D-17491 Greifswald (Germany); Greuner, Henri; Lindig, Stefan [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstr. 2, D-85748 Garching (Germany)

    2011-10-15

    Several designs of Langmuir probes for the stellarator Wendelstein 7-X (W7-X) are described. Different types of probes are proposed for the different divertors to be used during different operational phases of W7-X. Comb-like arrays of stiff probes, arrays of flexible probes, and fixed inlay probes are reviewed. For the initial phase of W7-X it was decided to install arrays of fixed inlay probes. Two mockups were manufactured and one of them was tested with success in the high heat flux test facility GLADIS. For long-pulse operation of W7-X different conceptual designs are proposed and are still developed further. This paper summarizes the different design constrains for the Langmuir probes in the different divertor surroundings, describes the design of the array of inlay probes for the initial phase and the result of the GLADIS test, and gives a preview of the conceptual designs of probes for the long-pulse operational phase of W7-X.

  12. Overnight Changes Recorded by Phoenix Conductivity Probe

    Science.gov (United States)

    2008-01-01

    This graph presents simplified data from overnight measurements by the Thermal and Electrical Conductivity Probe on NASA's Phoenix Mars Lander from noon of the mission's 70th Martian day, or sol, to noon the following sol (Aug. 5 to Aug. 6, 2008). The graph shows that water disappeared from the atmosphere overnight, at the same time that electrical measurements detected changes consistent with addition of water to the soil. Water in soil appears to increase overnight, when water in the atmosphere disappears. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  13. Probing Cellular Dynamics with Mesoscopic Simulations

    DEFF Research Database (Denmark)

    Shillcock, Julian C.

    2010-01-01

    Cellular processes span a huge range of length and time scales from the molecular to the near-macroscopic. Understanding how effects on one scale influence, and are themselves influenced by, those on lower and higher scales is a critical issue for the construction of models in Systems Biology....... Advances in computing hardware and software now allow explicit simulation of some aspects of cellular dynamics close to the molecular scale. Vesicle fusion is one example of such a process. Experiments, however, typically probe cellular behavior from the molecular scale up to microns. Standard particle...... soon be coupled to Mass Action models allowing the parameters in such models to be continuously tuned according to the finer resolution simulation. This will help realize the goal of a computational cellular simulation that is able to capture the dynamics of membrane-associated processes...

  14. An approach to directly probe simultaneity

    CERN Document Server

    Kipreos, Edward T

    2016-01-01

    The theory of special relativity derives from the Lorentz transformation. The Lorentz transformation implies differential simultaneity and light speed isotropy. Experiments to probe differential simultaneity should be able to distinguish the Lorentz transformation from a kinematically-similar alternate transformation that predicts absolute simultaneity, the absolute Lorentz transformation. Here, we describe how published optical tests of light speed isotropy/anisotropy cannot distinguish between the two transformations. We show that the shared equations of the two transformations, from the perspective of the "stationary" observer, are sufficient to predict null results in optical resonator experiments and in tests of frequency changes in one-way light paths. In an influential 1910 exposition on differential simultaneity, Comstock described how a "stationary" observer would observe different clock readings for spatially-separated "moving" clocks. The difference in clock readings is an integral aspect of differ...

  15. Information Acquisition & Processing in Scanning Probe Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Sergei V [ORNL; Jesse, Stephen [ORNL; Proksch, Roger [Asylum Research, Santa Barbara, CA

    2008-01-01

    Much of the imaging and spectroscopy capabilities of the existing 20,000+ scanning probe microscopes worldwide relies on specialized data processing that links the microsecond (and sometimes faster) time scale of cantilever motion to the millisecond (and sometimes slower) time scale of image acquisition and feedback. In most SPMs, the cantilever is excited to oscillate sinusoidally and the time-averaged amplitude and/or phase are used as imaging or control signals. Traditionally, the step of converting the rapid motion of the cantilever into an amplitude or phase is performed by phase sensitive homodyne or phase-locked loop detection. The emergence of fast configurable data processing electronics in last several years has allowed the development of non-sinusoidal data acquisition and processing methods. Here, we briefly review the principles and limitations of phase sensitive detectors and discuss some of the emergent technologies based on rapid spectroscopic measurements in frequency- and time domains.

  16. 3'-functionalized adamantyl cannabinoid receptor probes.

    Science.gov (United States)

    Ogawa, Go; Tius, Marcus A; Zhou, Han; Nikas, Spyros P; Halikhedkar, Aneetha; Mallipeddi, Srikrishnan; Makriyannis, Alexandros

    2015-04-09

    The aliphatic side chain plays a pivotal role in determining the cannabinergic potency of tricyclic classical cannabinoids, and we have previously shown that this chain could be substituted successfully by adamantyl or other polycyclic groups. In an effort to explore the pharmacophoric features of these conformationally fixed groups, we have synthesized a series of analogues in which the C3 position is substituted directly with an adamantyl group bearing functionality at one of the tertiary carbon atoms. These substituents included the electrophilic isothiocyanate and photoactivatable azido groups, both of which are capable of covalent attachment with the target protein. Our results show that substitution at the 3'-adamantyl position can lead to ligands with improved affinities and CB1/CB2 selectivities. Our work has also led to the development of two successful covalent probes with high affinities for both cannabinoid receptors, namely, the electrophilic isothiocyanate AM994 and the photoactivatable aliphatic azido AM993 analogues.

  17. Electromagnetic probes in heavy-ion collisions

    Directory of Open Access Journals (Sweden)

    van Hees H.

    2015-01-01

    Full Text Available Due to their penetrating nature, electromagnetic probes, i.e., lepton-antilepton pairs (dileptons and photons are unique tools to gain insight into the nature of the hot and dense medium of strongly-interacting particles created in relativistic heavy-ion collisions, including hints to the nature of the restoration of chiral symmetry of QCD. Of particular interest are the spectral properties of the electromagnetic current-correlation function of these particles within the dense and/or hot medium. The related theoretical investigations of the in-medium properties of the involved particles in both the partonic and hadronic part of the QCD phase diagram underline the importance of a proper understanding of the properties of various hadron resonances in the medium.

  18. Radiation Belt Storm Probe (RBSP) Mission

    Science.gov (United States)

    Sibeck, D. G.; Fox, N.; Grebowsky, J. M.; Mauk, B. H.

    2009-01-01

    Scheduled to launch in May 2012, NASA's dual spacecraft Living With a Star Radiation Belt Storm Probe mission carries the field and particle instrumentation needed to determine the processes that produce enhancements in radiation belt ion and electron fluxes, the dominant mechanisms that cause the loss of relativistic electrons, and the manner by which the ring current and other geomagnetic phenomena affect radiation belt behavior. The two spacecraft will operate in low-inclination elliptical lapping orbits around the Earth, within and immediately exterior to the Van Allen radiation belts. During course of their two year primary mission, they will cover the full range of local times, measuring both AC and DC electric and magnetic fields to 10kHz, as well as ions from 50 eV to 1 GeV and electrons with energies ranging from 50 eV to 10 MeV.

  19. NASA's Radiation Belt Storm Probe Mission

    Science.gov (United States)

    Sibeck, David G.

    2011-01-01

    NASA's Radiation Belt Storm Probe (RBSP) mission, comprising two identically-instrumented spacecraft, is scheduled for launch in May 2012. In addition to identifying and quantifying the processes responsible for energizing, transporting, and removing energetic particles from the Earth's Van Allen radiation, the mission will determine the characteristics of the ring current and its effect upon the magnetosphere as a whole. The distances separating the two RBSP spacecraft will vary as they move along their 1000 km altitude x 5.8 RE geocentric orbits in order to enable the spacecraft to separate spatial from temporal effects, measure gradients that help identify particle sources, and determine the spatial extent of a wide array of phenomena. This talk explores the scientific objectives of the mission and the manner by which the mission has been tailored to achieve them.

  20. Probe suppression in conformal phased array

    CERN Document Server

    Singh, Hema; Neethu, P S

    2017-01-01

    This book considers a cylindrical phased array with microstrip patch antenna elements and half-wavelength dipole antenna elements. The effect of platform and mutual coupling effect is included in the analysis. The non-planar geometry is tackled by using Euler's transformation towards the calculation of array manifold. Results are presented for both conducting and dielectric cylinder. The optimal weights obtained are used to generate adapted pattern according to a given signal scenario. It is shown that array along with adaptive algorithm is able to cater to an arbitrary signal environment even when the platform effect and mutual coupling is taken into account. This book provides a step-by-step approach for analyzing the probe suppression in non-planar geometry. Its detailed illustrations and analysis will be a useful text for graduate and research students, scientists and engineers working in the area of phased arrays, low-observables and stealth technology.

  1. Probing Bino Contribution to Muon g-2

    CERN Document Server

    Endo, Motoi; Kikahara, Teppei; Yoshinaga, Takahiro

    2013-01-01

    We study SUSY models in which Bino contributions solve the muon $g-2$ anomaly. The contributions are enhanced by large left-right mixing of the smuons. However, it is constrained by the vacuum stability condition of the slepton--Higgs potential. Therefore, there are upper bounds on masses of sleptons and Bino. When the slepton soft masses are universal, the upper bound on the smuon mass becomes $330~(460)\\GeV$ in order to solve the $g-2$ anomaly at the $1\\sigma~(2\\sigma)$ level. It is within the reach of LHC and ILC. If the stau is heavier than the smuon, the bound can be as large as $1.4~(1.9)\\TeV$. Such non-universal slepton mass spectrum generically predicts too large LFV/CPV. We show that the models are expected to be probed by LHC/ILC and LFV/CPV complementarily in future.

  2. Probing the Casimir force with optical tweezers

    CERN Document Server

    Ether, D S; Umrath, S; Martinez, D; Ayala, Y; Pontes, B; Araújo, G R de S; Frases, S; Ingold, G -L; Rosa, F S S; Viana, N B; Nussenzveig, H M; Neto, P A Maia

    2015-01-01

    We propose to use optical tweezers to probe the Casimir interaction between microspheres inside a liquid medium for geometric aspect ratios far beyond the validity of the widely employed proximity force approximation. This setup has the potential for revealing unprecedented features associated to the non-trivial role of the spherical curvatures. For a proof of concept, we measure femtonewton double layer forces between polystyrene microspheres at distances above $400$ nm by employing very soft optical tweezers, with stiffness of the order of fractions of a fN/nm. As a future application, we propose to tune the Casimir interaction between a metallic and a polystyrene microsphere in saline solution from attraction to repulsion by varying the salt concentration. With those materials, the screened Casimir interaction may have a larger magnitude than the unscreened one. This line of investigation has the potential for bringing together different fields including classical and quantum optics, statistical physics an...

  3. Laser thermal probe recanalization of occluded arteries.

    Science.gov (United States)

    White, R A; White, G H

    1989-04-01

    Applications of laser energy for treatment of vascular disease have recently received much attention; metal-tipped laser probes are being investigated as a device for recanalization of occluded arteries, especially as an adjunct to balloon dilatation. Developments in instrumentation and techniques have reduced the incidence of complications, notably perforation, to an acceptable level. Initial data show that recanalization of iliac, femoral, and popliteal lesions can be accomplished in a majority of cases, with the chance of success being inversely proportional to the length of occlusion. Results in the tibial vessels are disappointing. Patency of the treated vessels at 12 months appears to be superior to that of percutaneous transluminal angioplasty for similar lesions but inferior to that of surgical bypass for all occlusions greater than 3 cm in length.

  4. CHAMP (Camera, Handlens, and Microscope Probe)

    Science.gov (United States)

    Mungas, Greg S.; Boynton, John E.; Balzer, Mark A.; Beegle, Luther; Sobel, Harold R.; Fisher, Ted; Klein, Dan; Deans, Matthew; Lee, Pascal; Sepulveda, Cesar A.

    2005-01-01

    CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

  5. Modeling Scattering Polarization for Probing Solar Magnetism

    CERN Document Server

    Bueno, Javier Trujillo

    2011-01-01

    This paper considers the problem of modeling the light polarization that emerges from an astrophysical plasma composed of atoms whose excitation state is significantly influenced by the anisotropy of the incident radiation field. In particular, it highlights how radiative transfer simulations in three-dimensional models of the quiet solar atmosphere may help us to probe its thermal and magnetic structure, from the near equilibrium photosphere to the highly non-equilibrium upper chromosphere. The paper finishes with predictions concerning the amplitudes and magnetic sensitivities of the linear polarization signals produced by scattering processes in two transition region lines, which should encourage us to develop UV polarimeters for sounding rockets and space telescopes with the aim of opening up a new diagnostic window in astrophysics.

  6. Spatial resolution in atom probe tomography

    CERN Document Server

    Gault, Baptiste; de Geuser, Frederic; La Fontaine, Alex; Stephenson, Leigh T; Haley, Daniel; Ringer, Simon P

    2015-01-01

    This article addresses gaps in definitions and a lack of standard measurement techniques to assess the spatial resolution in atom probe tomography. This resolution is known to be anisotropic, being better in the depth than laterally. Generally the presence of atomic planes in the tomographic reconstruction is considered as being a sufficient proof of the quality of the spatial resolution of the instrument. Based on advanced spatial distribution maps, an analysis methodology that interrogates the local neighborhood of the atoms within the tomographic reconstruction, it is shown how both the in-depth and the lateral resolution can be quantified. The influences of the crystallography and the temperature are investigated, and models are proposed to explain the observed results. We demonstrate that the absolute value of resolution is specimenspecific.

  7. Probing a slepton Higgs on all frontiers

    Energy Technology Data Exchange (ETDEWEB)

    Biggio, Carla [Dipartimento di Fisica, Università di Genova & INFN, Sezione di Genova, via Dodecaneso 33, 16159 Genova (Italy); Dror, Jeff Asaf; Grossman, Yuval; Ng, Wee Hao [Department of Physics, LEPP, Cornell University,Ithaca, NY 14853 (United States)

    2016-04-26

    We study several aspects of supersymmetric models with a U(1){sub R} symmetry where the Higgs doublet is identified with the superpartner of a lepton. We derive new, stronger bounds on the gaugino masses based on current measurements, and also propose ways to probe the model up to scales of O(10 TeV) at future e{sup +}e{sup −} colliders. Since the U(1){sub R} symmetry cannot be exact, we analyze the effects of R-symmetry breaking on neutrino masses and proton decay. In particular, we find that getting the neutrino mixing angles to agree with experiments in a minimal model requires a UV cutoff for the theory at around 10/,TeV.

  8. Probing SZ Source Detection with Gasdynamical Simulations

    CERN Document Server

    Bond, J R; Wadsley, J W; Gladders, M D; Ruetalo, Marcelo I.; Wadsley, James W.; Gladders, Michael D.

    2001-01-01

    The huge worldwide investment in CMB experiments should make the Sunyaev-Zeldovich (SZ) effect a key probe of the cosmic web in the near future. For the promise to be realized, substantial development of simulation and analysis tools to relate observation to theory is needed. The high nonlinearity and dissipative/feedback gas physics lead to highly non-Gaussian patterns that are much more difficult to analyze than Gaussian primary anisotropies for which the procedures are reasonably well developed. Historical forecasts for what CMB experiments might see used semi-analytic tools, including large scale map constructions, with localized and simplified pressure structures distributed on a point process of (clustered) sources. Hydro studies beyond individual cluster/supercluster systems were inadequate, but now large-volume simulations with high resolution are beginning to shift the balance. We illustrate this by applying ``Gasoline'' (parallelized Tree+SPH) computations to construct SZ maps and derive statistical...

  9. Customized MFM probes with high lateral resolution

    Directory of Open Access Journals (Sweden)

    Óscar Iglesias-Freire

    2016-07-01

    Full Text Available Magnetic force microscopy (MFM is a widely used technique for magnetic imaging. Besides its advantages such as the high spatial resolution and the easy use in the characterization of relevant applied materials, the main handicaps of the technique are the lack of control over the tip stray field and poor lateral resolution when working under standard conditions. In this work, we present a convenient route to prepare high-performance MFM probes with sub-10 nm (sub-25 nm topographic (magnetic lateral resolution by following an easy and quick low-cost approach. This allows one to not only customize the tip stray field, avoiding tip-induced changes in the sample magnetization, but also to optimize MFM imaging in vacuum (or liquid media by choosing tips mounted on hard (or soft cantilevers, a technology that is currently not available on the market.

  10. Gravity Probe B data system description

    Science.gov (United States)

    Bennett, Norman R.

    2015-11-01

    The Gravity Probe B data system, developed, integrated, and tested by Lockheed Missiles & Space Company, and later Lockheed Martin Corporation, included flight and ground command, control, and communications software. The development was greatly facilitated, conceptually and by the transfer of key personnel, through Lockheed’s earlier flight and ground test software development for the Hubble Space Telescope (HST). Key design challenges included the tight mission timeline (17 months, 9 days of on-orbit operation), the need to tune the system once on-orbit, and limited 2 Kbps real-time data rates and ground asset availability. The result was a completely integrated space vehicle and Stanford mission operations center, which successfully collected and archived 97% of the ‘guide star valid’ data to support the science analysis. Lessons learned and incorporated from the HST flight software development and on-orbit support experience, and Lockheed’s independent research and development effort, will be discussed.

  11. Probing Majorana Neutrino Textures at DUNE

    CERN Document Server

    Bora, Kalpana; Dutta, Debajyoti

    2016-01-01

    We study the possibility of probing different texture zero neutrino mass matrices at long baseline neutrino experiment DUNE. Assuming a diagonal charged lepton basis and Majorana nature of light neutrinos, we first classify the possible light neutrino mass matrices with one and two texture zeros and then numerically evaluate the parameter space in terms of atmospheric mixing angle $\\theta_{23}$ and Dirac CP phase $\\delta_{\\text{CP}}$ which satisfies the texture zero conditions. We then feed these parameter values into the numerical analysis in order to study the sensitivity of DUNE experiment to them. We find that the DUNE will be able to exclude some of these texture zero mass matrices which restrict the $(\\theta_{23}-\\delta_{\\text{CP}})$ to a very specific range of values.

  12. Probing crunching AdS cosmologies

    CERN Document Server

    Kumar, S Prem

    2015-01-01

    Holographic gravity duals of deformations of CFTs formulated on de Sitter spacetime contain FRW geometries behind a horizon, with cosmological big crunch singularities. Using a specific analytically tractable solution within a particular single scalar truncation of N=8 supergravity on AdS_4, we first probe such crunching cosmologies with spacelike radial geodesics that compute spatially antipodal correlators of large dimension boundary operators. At late times, the geodesics lie on the FRW slice of maximal expansion behind the horizon. The late time two-point functions factorise, and when transformed to the Einstein static universe, they exhibit a temporal non-analyticity determined by the maximal value of the scale factor a_{max} . Radial geodesics connecting antipodal points necessarily have de Sitter energy E \\leq a_{max}, while geodesics with E > a_{max} terminate at the crunch, the two categories of geodesics being separated by the maximal expansion slice. The spacelike crunch singularity is curved "outw...

  13. Holography, probe branes and isoperimetric inequalities

    Directory of Open Access Journals (Sweden)

    Frank Ferrari

    2015-07-01

    Full Text Available In many instances of holographic correspondences between a d-dimensional boundary theory and a (d+1-dimensional bulk, a direct argument in the boundary theory implies that there must exist a simple and precise relation between the Euclidean on-shell action of a (d−1-brane probing the bulk geometry and the Euclidean gravitational bulk action. This relation is crucial for the consistency of holography, yet it is non-trivial from the bulk perspective. In particular, we show that it relies on a nice isoperimetric inequality that must be satisfied in a large class of Poincaré–Einstein spaces. Remarkably, this inequality follows from theorems by Lee and Wang.

  14. Chemical sensor with oscillating cantilevered probe

    Science.gov (United States)

    Adams, Jesse D

    2013-02-05

    The invention provides a method of detecting a chemical species with an oscillating cantilevered probe. A cantilevered beam is driven into oscillation with a drive mechanism coupled to the cantilevered beam. A free end of the oscillating cantilevered beam is tapped against a mechanical stop coupled to a base end of the cantilevered beam. An amplitude of the oscillating cantilevered beam is measured with a sense mechanism coupled to the cantilevered beam. A treated portion of the cantilevered beam is exposed to the chemical species, wherein the cantilevered beam bends when exposed to the chemical species. A second amplitude of the oscillating cantilevered beam is measured, and the chemical species is determined based on the measured amplitudes.

  15. Atom probe analysis of titanium hydride precipitates.

    Science.gov (United States)

    Takahashi, J; Kawakami, K; Otsuka, H; Fujii, H

    2009-04-01

    It is expected that the three-dimensional atom probe (3DAP) will be used as a tool to visualize the atomic scale of hydrogen atoms in steel is expected, due to its high spatial resolution and very low detection limit. In this paper, the first 3DAP analysis of titanium hydride precipitates in metal titanium is reported in terms of the quantitative detection of hydrogen. FIB fabrication techniques using the lift-out method have enabled the production of needle tips of hydride precipitates, of several tens of microns in size, within a titanium matrix. The hydrogen concentration estimated from 3DAP analysis was slightly smaller than that of the hydride phase predicted from the phase diagram. We discuss the origin of the difference between the experimental and predicted values and the performance of 3DAP for the quantitative detection of hydrogen.

  16. Probing General Relativity with Accreting Black Holes

    CERN Document Server

    Fabian, A C

    2012-01-01

    Most of the X-ray emission from luminous accreting black holes emerges from within 20 gravitational radii. The effective emission radius is several times smaller if the black hole is rapidly spinning. General Relativistic effects can then be very important. Large spacetime curvature causes strong lightbending and large gravitational redshifts. The hard X-ray, power-law-emitting corona irradiates the accretion disc generating an X-ray reflection component. Atomic features in the reflection spectrum allow gravitational redshifts to be measured. Time delays between observed variations in the power-law and the reflection spectrum (reverberation) enable the physical scale of the reflecting region to be determined. The relative strength of the reflection and power-law continuum depends on light bending. All of these observed effects enable the immediate environment of the black hole where the effects of General Relativity are on display to be probed and explored.

  17. Probing the Planck Scale with Proton Decay

    Energy Technology Data Exchange (ETDEWEB)

    Harnik, Roni; Larson, Daniel T.; Murayama, Hitoshi; Thormeier, Marc

    2004-04-28

    We advocate the idea that proton decay may probe physics at the Planck scale instead of the GUT scale. This is possible because supersymmetric theories have dimension-5 operators that can induce proton decay at dangerous rates, even with R-parity conservation. These operators are expected to be suppressed by the same physics that explains the fermion masses and mixings. We present a thorough analysis of nucleon partial lifetimes in models with a string-inspired anomalous U(1)_X family symmetry which is responsible for the fermionic mass spectrum as well as forbidding R-parity violating interactions. Protons and neutrons can decay via R-parity conserving non-renormalizable superpotential terms that are suppressed by the Planck scale and powers of the Cabibbo angle. Many of the models naturally lead to nucleon decay near present limits without any reference to grand unification.

  18. Probing neutrinoless double beta decay with SNO+

    CERN Document Server

    Arushanova, Evelina

    2015-01-01

    Probing neutrinoless double beta decay is one of the primary goals for SNO+, SNOLAB's multi-purpose neutrino detector. In order to achieve this goal the SNO detector has been adapted so that it can be filled with Te-loaded liquid scintillator. During the initial double beta phase the target loading is 0.3% natural Te, which equates to $\\sim790$ kg of double beta isotope. Estimating the sensitivity to neutrinoless double beta decay requires a well understood background model. For SNO+ this is provided by a comprehensive study considering all possible background contributions, whether they originate from within the liquid scintillator cocktail, the surrounding parts of the detector or other irreducible backgrounds. Given these considerations, for five years running in the initial phase, the expected sensitivity is $T_{1/2}^{0\

  19. A Quirky Probe of Neutral Naturalness

    CERN Document Server

    Chacko, Zackaria; Verhaaren, Christopher B

    2015-01-01

    We consider the signals arising from top partner pair production at the LHC as a probe of theories of Neutral Naturalness. We focus on scenarios in which the top partners carry electroweak charges, such as Folded SUSY or the Quirky Little Higgs. In this class of theories the top partners are charged under a mirror color group whose lightest states are hidden glueballs. The top partners, once produced, form a quirky bound state that de-excites promptly and annihilates into hidden glueballs. These glueballs can decay through mixing with the Higgs, giving rise to striking displaced signatures at the LHC. We show that the displaced signals arising from top partner pair production constitute the primary discovery channel for this class of theories in most regions of parameter space.

  20. Probing Quantum Violations of the Equivalence Principle

    CERN Document Server

    Adunas, G Z; Ahluwalia, D V

    2001-01-01

    The joint realm of quantum mechanics and the general-relativistic description of gravitation is becoming increasingly accessible to terrestrial experiments and observations. In this essay we study the emerging indications of the violation of equivalence principle (VEP). While the solar neutrino anomaly may find its natural explanation in a VEP, the statistically significant discrepancy observed in the gravitationally induced phases of neutron interferometry seems to be the first indication of a VEP. However, such a view would seem immediately challenged by the atomic interferometry results. The latter experiments see no indications of VEP, in apparent contradiction to the neutron interferometry results. Here we present arguments that support the view that these, and related torsion pendulum experiments, probe different aspects of gravity; and that current experimental techniques, when coupled to the solar-neutrino data, may be able to explore quantum mechanically induced violations of the equivalence principl...