WorldWideScience

Sample records for nonluminous induced capillaries

  1. Nonluminous Spray Combustion in a Jet-Mixing-Type Combustor

    OpenAIRE

    1990-01-01

    A new combustion system called a jet-mixing-type combustor was designed to obtain a nonluminous blue flame of a kerosene spray. A spray was injected by a conventional-type swirl atomizer into the combustor, and combustion air was introduced through a baffle plate with 16 inlet holes. The principle of this combustion method was revealed as a prompt mixing of the air and spray, which was achieved by high-speed air jets. The combustion characteristics such as combustion stability, temperature di...

  2. Capillary electrophoresis with laser-induced fluorescence: environmental applications.

    Science.gov (United States)

    Riddick, Lee; Brumley, William C

    2008-01-01

    Capillary electrophoresis (CE), especially free-zone CE, offers a relatively simple separation with moderate selectivity based on the mobility of ions in solution. Laser-induced fluorescence (LIF) detection, an extremely sensitive technique, can be coupled with a variety of separation conditions to achieve sensitive and quantitative results. When these techniques are combined, CE/LIF provides the sensitivity and increased selectivity that makes trace level environmental analysis of fluorescent compounds possible at or below levels typical for gas chromatography (GC)/mass spectrometry (MS). We offer a panoramic review of the role of these tools in solving environmental and related analytical problems before providing a detailed experimental protocol.

  3. Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Dickerson, Jane A; Ramsay, Lauren M; Dada, Oluwatosin O; Cermak, Nathan; Dovichi, Norman J

    2010-08-01

    CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first-dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second-dimension separation. A fraction was transferred to the second-dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125.

  4. Development of infrared spectral radiation measurement system of a non-luminous flame

    Institute of Scientific and Technical Information of China (English)

    Zhao Jin; Maohua Yang; Guibin Yuan; Jingmin Dai

    2005-01-01

    @@ The spectral radiation characteristic of a non-luminous flame is analyzed. The apparatus and the calibration procedure based on infrared emission spectrometry for measurements of the flame are introduced.The influence of background radiation and stray light on the measurement results could be reduced and suppressed by the design of thermolator and digital lock-in technique. A blackbody cavity was used as reference emission source to calibrate the system that completed absolute measurement. The spectral measurement range is 1-20 μm. The least measuring distance and the lowest power detected at the entrance pupil are 550 mm and 10-9 W/cm2, respectively. The experimental results show that the measure error is less than 10%.

  5. Design and evaluation of capillary coupled with optical fiber light-emitting diode induced fluorescence detection for capillary electrophoresis.

    Science.gov (United States)

    Ji, Hongyun; Li, Meng; Guo, Lihong; Yuan, Hongyan; Wang, Chunling; Xiao, Dan

    2013-09-01

    A new detector, capillary coupled with optical fiber LED-induced fluorescence detector (CCOF-LED-IFD, using CCOF for short), is introduced for CE. The strategy of the present work was that the optical fiber and separation capillary were, in the parallel direction, fastened in a fixation capillary with larger inner diameter. By employing larger inner diameter, the fixation capillary allowed the large diameter of the optical fiber to be inserted into it. By transmitting an enhanced excitation light through the optical fiber, the detection sensitivity was improved. The advantages of the CCOF-CE system were validated by the detection of riboflavin, and the results were compared to those obtained by the in-capillary common optical fiber LED-induced fluorescence detector (IC-COF-LED-IFD, using COF for short). The LODs of CCOF-CE and COF-CE were 0.29 nM and 11.0 nM (S/N = 3), respectively. The intraday (n = 6) repeatability and interday (n = 6) reproducibility of migration time and corresponding peak area for both types of CE were all less than 1.10 and 3.30%, respectively. The accuracy of the proposed method was judged by employing standard addition method, and recoveries obtained were in the range of 98.0-102.4%. The results indicated that the sensitivity of the proposed system was largely improved, and that its reproducibility and accuracy were satisfactory. The proposed system was successfully applied to separate and determine riboflavin in real sample.

  6. Anabolic steroids impair the exercise-induced growth of the cardiac capillary bed.

    Science.gov (United States)

    Tagarakis, C V; Bloch, W; Hartmann, G; Hollmann, W; Addicks, K

    2000-08-01

    Concomitant application of anabolic-androgenic steroids and physical exercise can induce cardiac hypertrophy. These experiments investigate the still unknown response of the cardiac myocytes and capillaries to the combined influence of various anabolic steroids and muscular exercise. Female SPF-NMRI mice were divided into the following groups: a) sedentary control, b) exercise (treadmill running); c) sedentary receiving Dianabol; d) exercise + Dianabol; e) exercise + Oral-Turinabol. After 3 and 6 weeks the left ventricular papillary muscles were studied morphometrically. Evaluated variables: minimal myocyte diameter, number of capillaries around a single myocyte, capillary density and intercapillary distance. Only the anabolic steroids + exercise groups showed a mild myocyte hypertrophy. In contrast, only exercise alone caused a significant increase of the capillary density after both experimental periods; e.g. capillary density after 6 weeks (capillaries/mm2, mean values +/- standard deviation, p turinabol + exercise (4,053 +/- 306). Moreover, unlike all other regimens, only exercise alone shortened the intercapillary distance. Finally, exercise without drugs induced the greatest increase in the number of capillaries around a single myocyte. Anabolic steroids combined with exercise: 1) induce mild hypertrophy of the cardiac myocytes, 2) impair the cardiac microvascular adaptation to physical conditioning. The microvascular impairment may cause a detrimental alteration of the myocardial oxygen supply, especially during muscular exercise.

  7. Induced hydraulic pumping via integrated submicrometer cylindrical glass capillaries.

    Science.gov (United States)

    Cao, Zhen; Yobas, Levent

    2014-08-01

    Here, we report on a micropump that generates hydraulic pressure owing to a mismatch in EOF rates of microchannels and submicrometer cylindrical glass capillaries integrated on silicon. The electrical conductance of such capillaries in the dilute limit departs from bulk linear behavior as well as from the surface-charge-governed saturation in nanoslits that is well described by the assumption of a constant surface charge density. The capillaries show rather a gradual decrease in conduction at low salt concentrations, which can be explained more aptly by a variable surface charge density that accounts for chemical equilibrium of the surface. The micropump uses a traditional cross-junction structure with ten identical capillaries integrated in parallel on a side arm and each with a 750 nm diameter and 3 mm length. For an applied voltage of 700 V, a hydraulic pressure up to 5 kPa is generated with a corresponding flow velocity nearly 3 mm/s in a straight field-free branch 20 μm wide, 10 μm deep, and 10 mm long. The micropump utility has been demonstrated in an open tubular LC of three fluorescently labeled amino acids in just less than 20 s with minimal plate height values between 3 and 7 μm. The submicrometer capillaries are self-enclosed and produced through a unique process that does not require high-resolution advanced lithography or wafer-bonding techniques to define their highly controlled precise structures. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Harvesting liquid from unsaturated vapor - nanoflows induced by capillary condensation

    Science.gov (United States)

    Vincent, Olivier; Marguet, Bastien; Stroock, Abraham

    2016-11-01

    A vapor, even subsaturated, can spontaneously form liquid in nanoscale spaces. This process, known as capillary condensation, plays a fundamental role in various contexts, such as the formation of clouds or the dynamics of hydrocarbons in the geological subsurface. However, large uncertainties remain on the thermodynamics and fluid mechanics of the phenomenon, due to experimental challenges as well as outstanding questions about the validity of macroscale physics at the nanometer scale. We studied experimentally the spatio-temporal dynamics of water condensation in a model nanoporous medium (pore radius 2 nm), taking advantage of the color change of the material upon hydration. We found that at low relative humidities (diffusive fashion, while it occurred through a well-defined capillary-viscous imbibition front at > 60 % RH, driven by a balance between the pore capillary pressure and the condensation stress given by Kelvin equation. Further analyzing the imbibition dynamics as a function of saturation allowed us to extract detailed information about the physics of nano-confined fluids. Our results suggest excellent extension of macroscale fluid dynamics and thermodynamics even in pores 10 molecules in diameter.

  9. Field induced rotational viscosity of ferrofluid: effect of capillary size and magnetic field direction.

    Science.gov (United States)

    Andhariya, Nidhi; Chudasama, Bhupendra; Patel, Rajesh; Upadhyay, R V; Mehta, R V

    2008-07-01

    In the present investigation we report the effect of capillary diameter and the direction of applied magnetic field on the rotational viscosity of water and kerosene based ferrofluids. We found that changes in the field induced rotational viscosity are larger in the case of water based magnetic fluid than that of kerosene based fluid. The field induced rotational viscosity is found to be inversely proportional to the capillary diameter and it falls exponentially as a function of the angle between the direction of field and vorticity of flow. Magnetophoretic mobility and hydrodynamic volume fraction of nanomagnetic particles are determined for above cases.

  10. Heterogeneous Nucleation Induced by Capillary Wave During Acoustic Levitation

    Institute of Scientific and Technical Information of China (English)

    吕勇军; 解文军; 魏炳波

    2003-01-01

    The rapid solidification of acoustically levitated drops of Pb-61.9 wt. %Sn eutectic alloy is accomplished. A surface morphology of spreading ripples is observed on a sample undercooled by 15 K. The ripples originate from the centre of sample surface, which is also the heterogeneous nucleation site for eutectic growth. The Faraday instability excited by forced surface vibration has brought about these ripples. They are retained in the solidified sample if the sound pressure level exceeds the threshold pressure required for the appearance of capillary waves.Theoretical calculations indicate that both the pressure and displacement maxima exist in the central part of a levitated drop. The pressure near the sample centre can promote heterogeneous nucleation, which is in agreement qualitatively with the experimental results.

  11. Instability of water jet: Aerodynamically induced acoustic and capillary waves

    Science.gov (United States)

    Broman, Göran I.; Rudenko, Oleg V.

    2012-09-01

    High-speed water jet cutting has important industrial applications. To further improve the cutting performance it is critical to understand the theory behind the onset of instability of the jet. In this paper, instability of a water jet flowing out from a nozzle into ambient air is studied. Capillary forces and compressibility of the liquid caused by gas bubbles are taken into account, since these factors have shown to be important in previous experimental studies. A new dispersion equation, generalizing the analogous Rayleigh equation, is derived. It is shown how instability develops because of aerodynamic forces that appear at the streamlining of an initial irregularity of the equilibrium shape of the cross-section of the jet and how instability increases with increased concentration of gas bubbles. It is also shown how resonance phenomena are responsible for strong instability. On the basis of the theoretical explanations given, conditions for stable operation are indicated.

  12. Capillary electrophoresis with laser-induced fluorescence detection for fast and reliable apolipoprotein E genotyping

    NARCIS (Netherlands)

    Somsen, GW; Welten, HTME; Mulder, FP; Swart, CW; Kema, IP; de Jong, GJ

    2002-01-01

    The use of capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection for the rapid determination of apolipoprotein E (apoE) genotypes was studied. High resolution and sensitive detection of the concerned DNA restriction fragments was achieved using CE buffers with hydroxypropylm

  13. Capillary Electrophoretic Immunoassay with Laser-induced Fluorescence Detection for Interferon-gamma

    Institute of Scientific and Technical Information of China (English)

    Hua ZHANG; Hai Ming WEI; Wen Rui JIN

    2004-01-01

    Capillary electrophoretic immunoassay with laser-induced fluorescence detection for recombinant human interferon-gamma (IFN-γ) was established. The limits of detection for three forms of IFN-γare 6.9 ng/L, 5.7 ng/L and 5.0 ng/L, respectively.

  14. X-ray lasing as a result of an induced instability in an ablative capillary discharge

    NARCIS (Netherlands)

    Ellwi, S. S.; Juschkin, L.; Ferri, S.; Kunze, H. J.; Koshelev, K. N.; E. Louis,

    2001-01-01

    We report lasing of the CVI Balmer-alpha line at 18.22 nm using the new technique of an induced MHD instability in an ablative capillary discharge. A large spike of this line during the second half-cycle of the discharge is observed. The spike is identified as amplified spontaneous emission (ASE), a

  15. Coronaridine congeners inhibit human α3β4 nicotinic acetylcholine receptors by interacting with luminal and non-luminal sites.

    Science.gov (United States)

    Arias, Hugo R; Targowska-Duda, Katarzyna M; Feuerbach, Dominik; Jozwiak, Krzysztof

    2015-08-01

    To characterize the interaction of coronaridine congeners with human (h) α3β4 nicotinic acetylcholine receptors (AChRs), structural and functional approaches were used. The Ca(2+) influx results established that coronaridine congeners noncompetitively inhibit hα3β4 AChRs with the following potency (IC50's in μM) sequence: (-)-ibogamine (0.62±0.23)∼(+)-catharanthine (0.68±0.10)>(-)-ibogaine (0.95±0.10)>(±)-18-methoxycoronaridine [(±)-18-MC] (1.47±0.21)>(-)-voacangine (2.28±0.33)>(±)-18-methylaminocoronaridine (2.62±0.57 μM)∼(±)-18-hydroxycoronaridine (2.81±0.54)>(-)-noribogaine (6.82±0.78). A good linear correlation (r(2)=0.771) between the calculated IC50 values and their polar surface area was found, suggesting that this is an important structural feature for its activity. The radioligand competition results indicate that (±)-18-MC and (-)-ibogaine partially inhibit [(3)H]imipramine binding by an allosteric mechanism. Molecular docking, molecular dynamics, and in silico mutation results suggest that protonated (-)-18-MC binds to luminal [i.e., β4-Phe255 (phenylalanine/valine ring; position 13'), and α3-Leu250 and β4-Leu251 (leucine ring; position 9')], non-luminal, and intersubunit sites. The pharmacophore model suggests that nitrogens from the ibogamine core as well as methylamino, hydroxyl, and methoxyl moieties at position 18 form hydrogen bonds. Collectively our data indicate that coronaridine congeners inhibit hα3β4 AChRs by blocking the ion channel's lumen and probably by additional negative allosteric mechanisms by interacting with a series of non-luminal sites.

  16. A new post-column reactor-laser induced fluorescence detector for capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Liling, Zhang [Iowa State Univ., Ames, IA (United States)

    1996-01-02

    Capillary zone electrophoresis (CZE), a powerful separation method based on the differential migration of charged species under the influence of an electric field, has been widely used for separations covering from small ions to big biomolecules. Chapter 1 describes the method, then discusses detection of the separated analytes by laser induced fluorescence and by chemical derivatization, and the use of O-phthaldialdehyde (OPA) as a post-column reagent. Chapter 2 describes a post-column reactor which uses two narrow bore capillaries connected coaxially. This reactor differs from other coaxial reactors in terms of capillary dimensions, reagent flow control, ease of construction and most importantly, better limits of detection. The derivatization reagent is electroosmotically driven into the reaction capillary and the reagent flow rate is independently controlled by a high voltage power supply. Amino acids, amines and proteins, derivatized by OPA/2-mercaptoethanol using this post-column reactor coupled with LIF detection, show low attomole mass limits of detection, and for the first time, the authors demonstrate single cell capability with a post-column derivatization scheme. The single cell capability shows that this reactor could find applications in assaying non-fluorescent or electrochemically inactive components in individual biological cells in the future.

  17. Determination of RNA degradation by capillary electrophoresis with cyan light-emitted diode-induced fluorescence.

    Science.gov (United States)

    Yang, Tzu-Hsueh; Chang, Po-Ling

    2012-05-25

    RNA integrity plays an important role in RNA studies because poor RNA quality may have a great impact on downstream methodologies. This study proposes a cost-effective, rapid, and sensitive method for determining RNA integrity based on capillary electrophoresis that utilizes a cyan light-emitted diode-induced fluorescence as a separation tool. The capillary was initially coated with 0.1% Poly(vinylpyrrolidone) (M(ave) 1,300,000 Da) to reduce electroosmotic flow and avoid RNA adsorption. When the capillary was filled with 0.4% poly(ethylene) oxide (M(ave) 4,000,000) and a nucleic acid-specific fluorescent dye, SYTO 9, the baseline separation of the 18S and 28S ribosomal RNAs (rRNAs) in total RNA was accomplished within 15 min. The lowest detectable concentration for the 18S and 28S rRNAs was estimated to be 50 pg/μL. Some peaks longer than the 28S rRNA that migrated slowly were observed as long as the initial total RNA concentration was optimized. The temperature-induced degradation of the large RNA fragments (longer than the 28S rRNA) was faster than that of 18S rRNA and 28S rRNA. These large RNA fragments may serve as a promising marker for testing RNA integrity compared to the traditional method. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. The Tip-Induced Twisted Bilayer Graphene Superlattice on HOPG: Capillary Attraction Effect

    CERN Document Server

    Yin, Long Jing; Feng, Ke Ke; Dou, Rui-Fen; Nie, Jia-Cai

    2014-01-01

    We use the tip of the scanning tunneling microscope (STM) to manipulate single weakly bound nanometer-sized sheets on the the highly oriented pyrolytic graphite (HOPG) surface through artifically increasing the tip and sample interaction in humid environment. By this means it is possible to tear apart a graphite sheet againt a step and fold this part onto the HOPG surface and thus generate the gaphene superlattices with hexagonal symmetry. The tip and sample surface interactions, including the van der Waals force, eletrostatic force and capillary attraction force originating from the Laplace pressure due to the formation of a highly curved fluid meniscus connecting the tip and sample, are discussed in details to understand the fromation mechnism of graphen superlattice induced by the STM tip. Especially, the capillary force is the key role in manipulating the graphite surface sheet in the hunmidity condition. Our approach may provides a simple and feasible route to prepare the controllable superlattices and g...

  19. High-fat feeding induces angiogenesis in skeletal muscle and activates angiogenic pathways in capillaries.

    Science.gov (United States)

    Silvennoinen, Mika; Rinnankoski-Tuikka, Rita; Vuento, Mikael; Hulmi, Juha J; Torvinen, Sira; Lehti, Maarit; Kivelä, Riikka; Kainulainen, Heikki

    2013-04-01

    High-fat diet (HFD) increases fatty acid oxidation in skeletal muscles. We hypothesized that this leads to increased oxygen demand and thus to increased capillarization. We determined the effects of high-fat diet on capillarization and angiogenic factors in skeletal muscles of mice that were either active or sedentary. Fifty-eight C57BL/6 J mice were divided into four groups: low-fat diet sedentary (LFS), low-fat diet active (LFA), high-fat diet sedentary (HFS), and high-fat diet active (HFA). The mice in active groups were housed in cages with running wheels and the sedentary mice were housed in similar cages without running wheels. After 19 weeks HFS, LFA and HFA had higher capillary density and capillary-to-fiber-ratio in quadriceps femoris muscles than LFS. Capillarization was similar in HFS and HFA. To reveal possible mechanisms of HFD induced angiogenesis, we measured protein and mRNA levels of angiogenic factors VEGF-A, HIF-1α, PGC-1α and ERRα. VEGF-A protein levels were higher in muscles of HFS, LFA and HFA compared to LFS. However, no significant differences were observed between HFA and HFS. Protein levels of HIF-1α, PGC-1α, and ERRα were similar in all groups. However, the mRNA expression of HIF-1α and VEGF-A was up-regulated in capillaries but not in muscle fibers of HFS. The sedentary and active mice groups had similar mRNA expression levels of angiogenesis regulators studied. We conclude that high-fat feeding induces angiogenesis in skeletal muscle and up-regulates the gene expression of HIF-1α and VEGF-A in capillaries.

  20. A compact micro-beam system using a tapered glass capillary for proton-induced X-ray radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Jun [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan)], E-mail: jhasegaw@nr.titech.ac.jp; Shiba, Shigeki; Fukuda, Hitoshi; Oguri, Yoshiyuki [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan)

    2008-05-15

    A compact micro-beam system, containing a tapered glass capillary tube with a tip diameter on the order of 10 {mu}m, was constructed to examine the applicability of capillary-generated micro-beams to high-contrast radiography based on proton-induced quasi-monochromatic X-rays. The transport efficiency of swift protons (2-3 MeV) through the capillary was examined as a function of the capillary tilt angle and the capillary tip diameter. We obtained transport efficiencies of approximately three times larger than would be expected from the geometrical shape of the capillary. This enhancement indicates that a focusing effect occurred in the capillary. A metallic thin foil was irradiated with the micro-beam and quasi-monochromatic X-rays were produced. By calculating the X-ray yields induced by proton bombardment in the foil and comparing them with the X-ray counts observed at the detector, the throughput efficiency of the X-ray imaging system was evaluated. We demonstrated magnification radiography of a small object to show that a spatial resolution on the order of 10 {mu}m was achievable in our system.

  1. Chiral separation of benzoporphyrin derivative mono- and diacids by laser induced fluorescence-capillary electrophoresis.

    Science.gov (United States)

    Peng, Xuejun; Sternberg, Ethan; Dolphin, David

    2002-01-01

    A method for the separation of benzoporphyrin derivative mono- and diacid (BPDMA, BPDDA) enantiomers by laser induced fluorescence-capillary electrophoresis (LIF-CE) has been developed. By using 300 mM borate buffer, pH 9.2, 25 mM sodium cholate and 10% acetronitrile as electrolyte, +10 kV electrokinetic sampling injection of 2 s and an applied +20 kV voltage across the ends of a 37 cm capillary (30 cm to the detector, 50 microm ID), all six BPD stereoisomers were baseline-separated within 20 min. Formation constants, free electrophoretic and complexation mobilities with borate and cholate were determined based on dynamic complexation capillary electrophoresis theory. The BPD enantiomers can be quantitatively determined in the range of 10(-2)-10(-5) mg mL(-1). The correlation coefficients (r2) of the least-squares linear regression analysis of the BPD enantiomers are in the range of 0.9914-0.9997. Their limits of detection are 2.18-3.5 x 10(-3) mg mL(-1). The relative standard deviations for the separation were 2.90-4.64% (n = 10). In comparison with high-performance liquid chromatography (HPLC), CE has better resolution and efficiency. This separation method was successfully applied to the BPD enantiomers obtained from a matrix of bovine serum and from liposomally formulated material as well as from studies with rat, dog and human microsomes.

  2. Perturbations of the flow induced by a microcapsule in a capillary tube

    Science.gov (United States)

    Gubspun, J.; de Loubens, C.; Trozzo, R.; Deschamps, J.; Georgelin, M.; Edwards-Levy, F.; Leonetti, M.

    2017-06-01

    Soft microcapsules moving in a cylindrical capillary deform from quasi-spherical shapes to elongated shapes with an inversion of curvature at the rear. We investigated the perturbation of the flow by particle tracking velocimetry around deformed microcapsules in confined flow. These experiments are completed by numerical simulations. Microcapsules are made of a thin membrane of polymerized human albumin and their shear elastic moduli are previously characterized in a cross flow chamber. Firstly, the velocity of the microcapsule can be calculated by theoretical predictions for rigid spheres, even for large deformations as ‘parachute-like’ shapes, if a relevant definition of the ratio of confinement is chosen. Secondly, at the rear and the front of the microcapsule, the existence of multiple recirculation regions is governed by the local curvature of the membrane. The amplitudes of these perturbations increase with the microcapsule deformation, whereas their axial extents are comparable to the radius of the capillary whatever the confinement and the capillary number. We conclude that whereas the motion of microcapsules in confined flow has quantitative similitudes with rigid spheres in terms of velocity and axial extent of the perturbation, their presence induces variations in the flow field that are related to the local deformation of the membrane as in droplets.

  3. Interparticle Capillary Forces at a Fluid-Fluid Interface with Strong Polymer-Induced Aging.

    Science.gov (United States)

    Cappelli, Stefano; de Jong, Arthur M; Baudry, Jean; Prins, Menno W J

    2017-01-24

    We report on a measurement of forces between particles adsorbed at a water-oil interface in the presence of an oil-soluble polymer. The cationic polymer interacts electrostatically with the negatively charged particles, thereby modulating the particle contact angle and the magnitude of capillary attraction between the particles. However, polymer adsorption to the interface also generates an increase in the apparent interfacial viscosity over several orders of magnitude in a time span of a few hours. We have designed an experiment in which repeated motion trajectories are measured on pairs of particles. The experiment gives an independent quantification of the interfacial drag coefficient (10(-7)-10(-4) Ns/m) and of the interparticle capillary forces (0.1-10 pN). We observed that the attractive capillary force depends on the amount of polymer in the oil phase and on the particle pair. However, the attraction appears to be independent of the surface rheology, with changes over a wide range of apparent viscosity values due to aging. Given the direction (attraction), the range (∼μm), and the distance dependence (∼1/S(5)) of the observed interparticle force, we interpret the force as being caused by quadrupolar deformations of the fluid-fluid interface induced by particle surface roughness. The results suggest that capillary forces are equilibrated in the early stages of interface aging and thereafter do not change anymore, even though strong changes in surface rheology still occur. The described experimental approach is powerful for studying dissipative as well as conservative forces of micro- and nanoparticles at fluid-fluid interfaces for systems out of equilibrium.

  4. Effect of overall drop deformation on flow-induced coalescence at low capillary numbers

    Science.gov (United States)

    Baldessari, Fabio; Leal, L. Gary

    2006-01-01

    Comparison of recent experimental results for flow-induced drop coalescence [H. Yang, C. C. Park, Y. T. Hu et al., "The coalescence of two equal-sized drops in a two-dimensional linear flow," Phys. Fluids13, 1087 (2001)] with existing theory provides the motivation for an examination of the theory. Specifically, for head-on collisions, the experiments show a plateau in the dependence of drainage time versus capillary number at low capillary number that could not be explained by either the existing scaling analysis or the existing thin-film theory of the film drainage process previously described in the pioneering work of Davis and co-workers [S. G. Yiantsios and R. H. Davis, "Close approach and deformation of two viscous drops due to gravity and van der Waals forces," J. Colloid Interface Sci. 144, 412 (1991); R. H. Davis, J. A. Schonberg, and J. M. Rallison, "The lubrication force between two viscous drops," Phys. Fluids A 1, 77 (1989); M. A. Rother, A. Z. Zinchenko, and R. H. Davis, "Buoyancy-driven coalescence of slightly deformable drops," J. Fluid Mech. 346, 117 (1997); S. G. Yiantsios and R. H. Davis, "On the buoyancy-driven motion of a drop towards a rigid surface or a deformable interface," J. Fluid Mech. 217, 547 (1990)]. Both of these results indicate that the existing theories, while fundamentally correct in concept, are incomplete in providing a framework for a comprehensive explanation of the experimental results. In the present paper, we reexamine the thin-film theory of Davis et al. in the low capillary number limit. We find that a quasistatic model in which deformation is localized within the thin film is in general not sufficient to describe the leading-order asymptotic approximation of the flow-induced collision and coalescence of two slightly deformable drops at low capillary number. Instead, the overall deformation induced in the drops by the external flow plays a key role in determining the initial film thickness needed for numerical simulation

  5. Capillary origami

    OpenAIRE

    Py, Charlotte; Reverdy, Paul; Doppler, L.; J. Bico; Roman, B.; Baroud, Charles,

    2007-01-01

    International audience; The hairs of a wet dog rushing out from a pond assemble into bundles; this is a common example of the effect of capillary forces on flexible structures. From a practical point of the deformation and adhesion of compliant structures induced by interfacial forces may lead to disastrous effects in mechanical microsystems.

  6. Restriction Enzyme Pattern Analysis of Mycobacteria DNA by Capillary Electrophoresis with Laser-induced Fluorescence Detection

    Institute of Scientific and Technical Information of China (English)

    Li Yuanqian; Wang Guoqing; Mi Jianping; Zhou Ying; Zeng Hongyan; Zhang Chaowu

    2006-01-01

    A new method for rapidly detecting restriction enzyme patterns of Mycobacterium DNA using capillary electrophoresis with laser-induced fluorescence detection (CE-LIFD)was developed.Polymerase chain reaction was used to amplify a 439-bp fragment of a 65,000-kDa(Mr)heat shock protein gene(hsp65)of Mycobacterium.After digesting amplification products by BstEII and HaeIII,patterns of enzyme cleavage products were detected by both CE-LIFD and agarose gel electrophoresis(AGE),respectively.Experimental parameters of CE were optimized.Restriction enzyme patterns of Mycobacterium DNA were detected in optimum electrophoresis conditions:a coated capillary column with a length of 50 cm and an internal diameter of 100 μm,an electrophoresis buffer of 45 mmol/1 Tris-boric acid-ethylenediaminetetraacetic acid,and a running voltage of 11 kV.The restriction enzyme patterns for eight species of mycobacteria were studied.Relative standard deviations of the relative migration times of DNA segments were<3.6%.Compared with AGE,CE is more outstanding in resolution and detection time,and it can be applied as a more effective means to DNA restriction enzyme pattern analysis.

  7. Foam on troubled water: Capillary induced finite-time arrest of sloshing waves

    Science.gov (United States)

    Viola, Francesco; Brun, P.-T.; Dollet, Benjamin; Gallaire, François

    2016-09-01

    Interfacial forces exceed gravitational forces on a scale small relative to the capillary length—two millimeters in the case of an air-water interface—and therefore dominate the physics of sub-millimetric systems. They are of paramount importance for various biological taxa and engineering processes where the motion of a liquid meniscus induces a viscous frictional force that exhibits a sublinear dependence in the meniscus velocity, i.e., a power law with an exponent smaller than one. Interested in the fundamental implications of this dependence, we use a liquid-foam sloshing system as a prototype to exacerbate the effect of sublinear friction on the macroscopic mechanics of multi-phase flows. In contrast to classical theory, we uncover the existence of a finite-time singularity in our system yielding the arrest of the fluid's oscillations. We propose a minimal theoretical framework to capture this effect, thereby amending the paradigmatic damped harmonic oscillator model. Our results suggest that, although often not considered at the macroscale, sublinear capillary forces govern the friction at liquid-solid and liquid-liquid interfaces.

  8. Multi-Site N-glycan mapping study 1: Capillary electrophoresis - laser induced fluorescence.

    Science.gov (United States)

    Szekrényes, Ákos; Park, SungAe Suhr; Santos, Marcia; Lew, Clarence; Jones, Aled; Haxo, Ted; Kimzey, Michael; Pourkaveh, Shiva; Szabó, Zoltán; Sosic, Zoran; Feng, Peng; Váradi, Csaba; de l'Escaille, François; Falmagne, Jean-Bernard; Sejwal, Preeti; Niedringhaus, Thomas; Michels, David; Freckleton, Gordon; Hamm, Melissa; Manuilov, Anastasiya; Schwartz, Melissa; Luo, Jiann-Kae; van Dyck, Jonathan; Leung, Pui-King; Olajos, Marcell; Gu, Yingmei; Gao, Kai; Wang, Wenbo; Wegstein, Jo; Tep, Samnang; Guttman, András

    2016-01-01

    An international team that included 20 independent laboratories from biopharmaceutical companies, universities, analytical contract laboratories and national authorities in the United States, Europe and Asia was formed to evaluate the reproducibility of sample preparation and analysis of N-glycans using capillary electrophoresis of 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled glycans with laser induced fluorescence (CE-LIF) detection (16 sites) and ultra high-performance liquid chromatography (UHPLC, 12 sites; results to be reported in a subsequent publication). All participants used the same lot of chemicals, samples, reagents, and columns/capillaries to run their assays. Migration time, peak area and peak area percent values were determined for all peaks with >0.1% peak area. Our results demonstrated low variability and high reproducibility, both, within any given site as well across all sites, which indicates that a standard N-glycan analysis platform appropriate for general use (clone selection, process development, lot release, etc.) within the industry can be established.

  9. Multi-Site N-glycan mapping study 1: Capillary electrophoresis – laser induced fluorescence

    Science.gov (United States)

    Szekrényes, Ákos; Park, SungAe Suhr; Santos, Marcia; Lew, Clarence; Jones, Aled; Haxo, Ted; Kimzey, Michael; Pourkaveh, Shiva; Szabó, Zoltán; Sosic, Zoran; Feng, Peng; Váradi, Csaba; de l'Escaille, François; Falmagne, Jean-Bernard; Sejwal, Preeti; Niedringhaus, Thomas; Michels, David; Freckleton, Gordon; Hamm, Melissa; Manuilov, Anastasiya; Schwartz, Melissa; Luo, Jiann-Kae; van Dyck, Jonathan; Leung, Pui-King; Olajos, Marcell; Gu, Yingmei; Gao, Kai; Wang, Wenbo; Wegstein, Jo; Tep, Samnang; Guttman, András

    2016-01-01

    An international team that included 20 independent laboratories from biopharmaceutical companies, universities, analytical contract laboratories and national authorities in the United States, Europe and Asia was formed to evaluate the reproducibility of sample preparation and analysis of N-glycans using capillary electrophoresis of 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled glycans with laser induced fluorescence (CE-LIF) detection (16 sites) and ultra high-performance liquid chromatography (UHPLC, 12 sites; results to be reported in a subsequent publication). All participants used the same lot of chemicals, samples, reagents, and columns/capillaries to run their assays. Migration time, peak area and peak area percent values were determined for all peaks with >0.1% peak area. Our results demonstrated low variability and high reproducibility, both, within any given site as well across all sites, which indicates that a standard N-glycan analysis platform appropriate for general use (clone selection, process development, lot release, etc.) within the industry can be established. PMID:26466659

  10. Determination of metoprolol in rabbit blood using capillary electrophoresis with laser-induced fluorescence detection

    Institute of Scientific and Technical Information of China (English)

    Yu Yun Chen; Wei Ping Yang; Zhu Jun Zhang

    2011-01-01

    This work described a sensitive method for determination of metoprolol in rabbit plasma. The method involved purification by ultrafiltration, derivatization with fluorescein isothiocyanate, determination by capillary electrophoresis (CE) coupled with laser-induced fluorescence (LIF) detector. Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition. The assay had a wide range (2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL. The intra-and inter-day precisions were satisfactory with relative standard deviation (RSD) less than 10.0% and accuracy within 10.0%. This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood. (c) 2010 Yu Yun Chen. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.

  11. Size-dependent ion-beam-induced anisotropic plastic deformation at the nanoscale by nonhydrostatic capillary stresses

    NARCIS (Netherlands)

    van Dillen, T.; van der Giessen, E.; Onck, P. R.; Polman, A.

    2006-01-01

    We develop a phenomenological model for size-dependent anisotropic plastic deformation of colloidal nanoparticles under ion irradiation. We show that, at the nanoscale, nonhydrostatic capillary stresses drive radiation-induced Newtonian viscous flow, counteracting the stress state that initiates the

  12. Bradykinin and histamine-induced cytosolic calcium increase in capillary endothelial cells of bovine adrenal medulla.

    Science.gov (United States)

    Vinet, Raúl; Cortés, Magdalena P; Alvarez, Rocío; Delpiano, Marco A

    2014-09-01

    We have assessed the effect of bradykinin and histamine on the cytosolic free calcium concentration ([Ca(2+)]i ) of bovine adrenal medulla capillary endothelial cells (BAMCECs). To measure [Ca(2+)]i changes in BAMCECs the intracellular fluorescent probe, fluo-3 AM, was used. Bradykinin (3 µM) produced a transient monophasic increase in [Ca(2+)]i , which was depressed by B1650 (0.1 µM), a B2-bradykinin receptor antagonist (D-Arg-[Hyp(3), Thi(5,8) , D-Phe(7)]-Bradykinin). Similarly, increase in [Ca(2+)]i induced by histamine was also depressed by tripolidine (0.1 µM), an H1-histamine receptor antagonist. [Ca(2+)]i increase induced by both agonists was unaffected in the absence of extracellular Ca(2+) or presence of antagonists of voltage operated Ca(2+) channels (VOCCs). Thapsigargin (1 µM) did not abolish the increase of [Ca(2+)]i produced by bradykinin, but abolished that of histamine. In contrast, caffeine (100 µM), abolished the [Ca(2+)]i response induced by bradykinin (3 µM), but did not affect the [Ca(2+)]i increase induced by histamine (100 µM). The results indicate the presence of B2 bradykinin- and H1 histamine-receptors in BAMCECs. Liberation of Ca(2+) induced by both agonists occurs through 2 different intracellular mechanisms. While bradykinin activates a sarco(endo) plasmic reticulum (SER) containing a SER Ca(2+) -ATPase (SERCA) thapsigargin-insensitive, histamine activates a SER containing a SERCA thapsigargin-sensitive. We suggest that the increase in [Ca(2+)]i induced by bradykinin and histamine could be of physiological relevance, modulating adrenal gland microcirculation.

  13. Human neutrophil elastase inhibition studied by capillary electrophoresis with laser induced fluorescence detection and microscale thermophoresis.

    Science.gov (United States)

    Syntia, Fayad; Nehmé, Reine; Claude, Bérengère; Morin, Philippe

    2016-01-29

    Capillary electrophoresis-laser induced fluorescence (CZE-LIF) and microscale thermophoresis (MST) were used for the first time to study the inhibition of human neutrophil elastase (HNE). We recently studied HNE kinetics (Km and Vmax) by developing an in-capillary CZE-LIF assay based on transverse diffusion of laminar flow profiles (TDLFP) for reactant mixing. In this work, the former assay was adapted to monitor HNE inhibition. Two natural well known HNE inhibitors from the triterpene family, ursolic acid and oleanolic acid, were tested to validate the developed assay. Since the solubility of pentacyclic triterpenes in aqueous media where the enzymatic reaction will take place is limited, the effect of DMSO and ethanol on HNE was studied using microscale thermophoresis (MST). An agglomeration of the enzyme was revealed when preparing the inhibitor in 5% (v/v) DMSO. This phenomenon did not occur in the presence of ethanol. Therefore, ethanol was used as inhibitor solvent, at a limited percentage of 20% (v/v). In these conditions and after optimization of the TDLFP approach, the repeatability (RSD on migration times and peak-areas inferior to 2.2%) of the CZE-LIF assay and the sensitivity (LOQ of few nM) were found to be satisfactory for conducting inhibition assays. IC50 values for ursolic and oleanolic acid were successfully determined. They were respectively equal to 5.62±0.10μM (r(2)=0.9807; n=3) and to 8.21±0.23μM (r(2)=0.9887; n=3). Excellent agreement was found between the results obtained by CE and those reported in literature which validates the developed method. Particularly, the CE-based assay is able to rank HNE inhibitors relative to each other. Furthermore, MST technique was used for evaluating HNE interaction with the ursolic acid. Up to 16 capillaries were automatically processed to obtain in one titration experiment the dissociation constant for the HNE-ursolic acid complex. Ki was found to be 2.72±0.66μM (n=3) which is in excellent agreement

  14. Capillary electrophoresis mass spectrometry as a potential tool to detect lithium-induced nephropathy: Preliminary results.

    Science.gov (United States)

    Raedler, Thomas J; Wittke, Stefan; Jahn, Holger; Koessler, Andreas; Mischak, Harald; Wiedemann, Klaus

    2008-04-01

    Lithium remains the treatment of choice for many patients suffering from bipolar disorder. However, long-term treatment with lithium carries the potential to cause renal and thyroid dysfunction. Lithium-induced nephropathies are characterised by deterioration of urinary concentrating ability as well as, less frequently, a progressive and potentially irreversible decrease in glomerular filtration rate (GFR). Pathological changes after treatment with lithium include both tubulointerstitial and glomerular changes. Besides monitoring of the kidney-function, no screening-instruments exist for early identification of patients at risk of lithium-induced nephropathy. CE-MS (capillary electrophoresis coupled to a mass spectrometer) is a new technique that has been applied to the differential diagnosis of nephropathies. We sought to determine if CE-MS can be used to identify lithium-induced renal changes. A urine-sample was obtained from 14 subjects (7 males, 7 females, mean age 51.1 years) under long-term treatment with lithium (mean duration 17.4 years, range 8-35 years) without known nephropathy (mean creatinine 0.96 mg/dl; range 0.7-1.6). Urine samples were stored at -20 degrees C until analysis. CE-MS was performed according to standard procedures and a screen for nephropathies was used. Among the 14 urine samples, two subjects tested positive for a nephropathy. One further subject had a borderline result. Since 3/14 subjects with no known nephropathy showed some degree of pathological findings, CE-MS from a urine-sample may be helpful for the early detection of renal damage under treatment with lithium. However, a specific screen for lithium-induced nephropathies still needs to be developed.

  15. Capillary Hemangioma

    Science.gov (United States)

    ... Frequently Asked Questions Español Condiciones Chinese Conditions Capillary Hemangioma En Español Read in Chinese What is a capillary hemangioma? A capillary hemangioma (“strawberry” birthmark) is a benign ( ...

  16. Ethanol-induced damage to mucosal capillaries of rat stomach. Ultrastructural features and effects of prostaglandin F2 beta and cysteamine

    Energy Technology Data Exchange (ETDEWEB)

    Trier, J.S.; Szabo, S.; Allan, C.H.

    1987-01-01

    Impairment of the mucosal microcirculation may contribute to ethanol-induced gastric mucosal damage. In this report, we describe diffuse and severe ultrastructural damage to the capillaries of the gastric glandular mucosa of the rat that occurred within 1 min after intragastric instillation of 100% ethanol. There was a gradient of damage in that endothelial cell structure was most severely disrupted in profiles of capillaries located close to the luminal surface but some morphologic evidence of damage was evident in the wall of capillary profiles to a mean depth of 256 micron. Capillary structure was generally normal in the deeper regions of the mucosa. Pretreatment with intragastric cysteamine, 30 mg/100 g, or intragastric prostaglandin F2 beta, 0.5 mg/100 g, significantly reduced the depth in the mucosa to which damage to capillaries extended. Pretreatment with intragastric prostaglandin F2 beta, 0.2 mg/100 g, afforded no significant protection. We conclude that a 1-min exposure to 100% ethanol induces striking damage to the microcirculation of glandular mucosa of the rat stomach with severe damage to capillary profiles near the lumen and sparing of capillary profiles near the muscularis mucosa, and pretreatment with the sulfhydryl agent, cysteamine, or with a large dose of prostaglandin F2 beta reduces the extent of but does not abolish ethanol-induced damage to gastric mucosal capillaries.

  17. Determination of phycobiliproteins by capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Viskari, P J; Kinkade, C S; Colyer, C L

    2001-07-01

    Phycobiliproteins are derived from the photosynthetic apparatus of cyanobacteria and eukaryotic algae. They are composed of a protein backbone to which linear tetrapyrrole chromophores are covalently bound. Furthermore, they are water-soluble highly fluorescent, and relatively stable at room temperature and neutral pH. For this reason, capillary electrophoresis-laser induced fluorescence (CE-LIF) seems the idea method for determination of these important proteins. The effects of buffer additives such as sodium dodecyl sulfate (SDS)and putrescine on the separation of the three major phycobiliprotein types, namely allophycocyanin, phycocyanin, and phycoerythrin, with excitation and emission maxima at 652/660, 615/647, and 565(494)/575 nm, respectively, are considered. Detection limits for these proteins by CE-LIF are some 60-500 times better than by absorbance detection. The development of a fast and sensitive CE-LIF assay such as this is of potential significance to our understand ing of chemical and biological oceanographic processes.

  18. Depletion forces induce visco-elasto-capillary thinning of non-Brownian suspensions

    Science.gov (United States)

    Harich, R.; Deblais, A.; Colin, A.; Kellay, H.

    2016-06-01

    Droplet pinch-off, which occurs when a drop of liquid detaches from a capillary, can be strongly modified in the presence of complex fluids such as polymer solutions and suspensions giving rise to long and slender filaments that thin slowly in time. While for polymers, the molecular conformations of the molecules in the filament are responsible for such a behavior, in suspensions the mechanisms at play remain to be deciphered. Here we show, experimentally, that while liquid bridges of non-Brownian suspensions of moderate concentrations have a thinning behavior very close to that of the solvent, the addition of short-chain polymers inducing depletion attractions between the particles in the suspension changes the thinning dynamics and gives rise to exponential thinning in time. The characteristic time of this dynamics increases with polymer concentration and therefore the intensity of the depletion forces at play. The tunability of this dynamics may be important for injket and 3D printing applications where short rupture times are sought for or in other situations where drop formation has to be minimized or inhibited.

  19. Laser induced fluorescence and Raman spectroscopy in capillary electrophoresis as an possible instrument for extraterrestrial life signs detection.

    Science.gov (United States)

    Mikhail, Gorlenko; Cheptcov, Vladimir; Anton, Maydykovskiy; Eugeniy, Vasilev

    The one of a significant aims in extraterrestrial exploration is a seeking for a life traces in a open space and planetary objects. Complex composition and unknown origin of suspected signs of life required у new analytical approaches and technical solutions. The promising assai here can be Laser induced fluorescence and Raman spectroscopy methods. The combined instrument developed by our team reveal the advantage of capillary electrophoresis assays in a junction with laser induced fluorescence detection technology. We optimized excitation configuration of fluorescence in capillary electrophoresis to reduce pumping laser power up to 1 mW and decrease background scattering. The improvement of the device sensitivity at poor sample concentration we achieved by incorporating fluorescence flow-through cuvette into spectrometer. That allows to simplify setup, to minimize weight and increase reproducibility of measurements. The device has been tasted in complex organic chemical mixes and microbial strains differentiation tasks. 3d multinational spectra allow us to increase the spectra information loads in comparison with ordinary capillary electrophoresis approaches. Possible updating the device with Raman approach can even furthermore multiple the differentiation power of the instrument. The analytical module developed using this approach can be potentially effectively used in extraterrestrial researches as a payload of the future spacecraft.

  20. A single-probe capillary microgripper induced by dropwise condensation and inertial release

    Science.gov (United States)

    Fan, Zenghua; Rong, Weibin; Wang, Lefeng; Sun, Lining

    2015-11-01

    A micromanipulation method based on liquid droplets is widely used as a non-destructive technology to pick-and-place micrometer-scale objects. We focus on the development of a single-probe capillary microgripper to execute reliable micromanipulation tasks. By controlling dropwise condensation on a probe tip, the water droplet volume on the hydrophobic tip surface can be varied dynamically, which helps establish appropriate capillary lifting forces during capturing tasks. An inertia-releasing strategy was utilized to implement a piezoelectric actuator integrated with the capillary microgripper and to address release problems caused by adhesion force action. The influence of droplet formation and the capillary lifting force generated during the manipulation process were characterized experimentally. Micromanipulation tests were conducted using a customized motion platform with viewing microscopes to verify the performance potential of the capillary microgripping tool. Experimental results indicated that polystyrene microspheres with 20-100 μm radii and micro-silicon chips (1.63-12.1 μN) were grasped reliably, and that adhered micro-objects could be placed on a target using the proposed microhandling technique of inertial release in ambient conditions.

  1. Exercise induced capillary growth in human skeletal muscle and the dynamics of VEGF

    DEFF Research Database (Denmark)

    Høier, Birgitte; Hellsten, Ylva

    2014-01-01

    In skeletal muscle, growth of capillaries is an important adaptation to exercise training that secures adequate diffusion capacity for oxygen and nutrients even at high intensity exercise when increases in muscle blood flow are profound. Mechanical forces present during muscle activity, such as s...

  2. Capillary electrophoresis of FITC labeled amino acids with laser-induced fluorescence detection

    Institute of Scientific and Technical Information of China (English)

    党福全; 陈义

    1999-01-01

    FITC labeled amino acids have been separated using a home-huilt capillary electrophoresis with a laserinduced fluorescence detection (CE-LIF) system. Seventeen peaks can now be generated from the twenty common amino acids. The key conditions lie in the optimization of pH, buffer electrolytes and buffer additives.

  3. Capillary sample

    Science.gov (United States)

    ... several times a day using capillary blood sampling. Disadvantages to capillary blood sampling include: Only a limited ... do not constitute endorsements of those other sites. Copyright 1997-2017, A.D.A.M., Inc. Duplication ...

  4. Impact of biochar and root-induced changes on metal dynamics in the rhizosphere of Agrostis capillaris and Lupinus albus.

    Science.gov (United States)

    Houben, David; Sonnet, Philippe

    2015-11-01

    Rhizosphere interactions are deemed to play a key role in the success of phytoremediation technologies. Here, the effects of biochar and root-induced changes in the rhizosphere of Agrostis capillaris L. and Lupinus albus L. on metal (Cd, Pb and Zn) dynamics were investigated using a biotest on a 2mm soil layer and a sequential extraction procedure (Tessier's scheme). In the bulk soil, the application of 5% biochar significantly reduced the exchangeable pool of metals primarily due to a liming effect which subsequently promoted the metal shift into the carbonate-bound pool. However, metals were re-mobilized in the rhizosphere of both A. capillaris and L. albus due to root-induced acidification which counteracted the liming effect of biochar. As a result, the concentrations of metals in roots and shoots of both plants were not significantly reduced by the application of biochar. Although the study should be considered a worst-case scenario because experimental conditions induced the intensification of rhizosphere processes, the results highlight that changes in rhizosphere pH can impact the effectiveness of biochar to immobilize metals in soil. Biochar has thus a potential as amendment for reducing metal uptake by plants, provided the acidification of the rhizosphere is minimized.

  5. Microalgae amino acid extraction and analysis at nanomolar level using electroporation and capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Nehmé, Reine; Atieh, Carla; Fayad, Syntia; Claude, Bérengère; Chartier, Agnès; Tannoury, Mona; Elleuch, Fatma; Abdelkafi, Slim; Pichon, Chantal; Morin, Philippe

    2017-01-01

    Amino acids play a key role in food analysis, clinical diagnostics, and biochemical research. Capillary electrophoresis with laser-induced fluorescence detection was used for the analysis of several amino acids. Amino acid labeling with fluorescein isothiocyanate was conducted using microwave-assisted derivatization at 80°C (680 W) during only 150 s. Good electrophoretic resolution was obtained using a background electrolyte composed of sodium tetraborate buffer (100 mM; pH 9.4) and β-cyclodextrin (10 mM), and the limits of quantification were 3-30 nM. The developed capillary electrophoresis with laser-induced fluorescence method was used to analyze amino acids in Dunaliella salina green algae grown under different conditions. A simple extraction technique based on electroporation of the cell membrane was introduced. A home-made apparatus allowed the application of direct and alternating voltages across the electrochemical compartment containing a suspension of microalgae in distilled water at 2.5 g/L. A direct voltage of 12 V applied for 4 min gave the optimum extraction yield. Results were comparable to those obtained with accelerated-solvent extraction. The efficiency of electroporation in destroying microalgae membranes was shown by examining the algae surface morphology using scanning electron microscopy. Stress conditions were found to induce the production of amino acids in Dunaliella salina cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Capillary-force-induced formation of luminescent polystyrene/(rare-earth-doped nanoparticle) hybrid hollow spheres.

    Science.gov (United States)

    Chen, Min; Xie, Lin; Li, Fuyou; Zhou, Shuxue; Wu, Limin

    2010-10-01

    This paper presents a "one-pot" procedure to synthesize polystyrene/(rare-earth-doped nanoparticles) (PS/REDNPs) hybrid hollow spheres via the in situ diffusion of organic core into inorganic shell under strong capillary force. In this approach, when carboxyl-capped PS colloids were deposited by different REDNPs in aqueous medium, such as LaF3:Eu3+, LaF3:Ce3+-Tb3+, and YVO4:Dy3+, PS/REDNPs inorganic-organic hybrid hollow spheres could be directly obtained via the in situ diffusion of core PS chains into the voids between rare-earth-doped nanoparticles through the strong capillary force. Not only is the synthetic procedure versatile and very simple, but also the obtained hybrid hollow spheres are hydrophilic and luminescent and could be directly used in chemical and biological fields.

  7. Analysis of serotonin in brain microdialysates using capillary electrophoresis and native laser-induced fluorescence detection.

    Science.gov (United States)

    Benturquia, Nadia; Couderc, François; Sauvinet, Valérie; Orset, Cyrille; Parrot, Sandrine; Bayle, Christophe; Renaud, Bernard; Denoroy, Luc

    2005-03-01

    Serotonin or 5-hydroxytryptamine (5-HT) is a major neurotransmitter in the central nervous system. In this work, a method for analyzing 5-HT in brain microdialysis samples using a commercially available capillary electrophoresis (CE) system has been developed. A pH-mediated in-capillary preconcentration of samples was performed, and after separation by capillary zone electrophoresis, native fluorescence of 5-HT was detected by a 266 nm solid-state laser. The separation conditions for the analysis of 5-HT in standard solutions and microdialysates have been optimized, and this method has been validated on both pharmacological and analytical bases. Separation of 5-HT was performed using a 80 mmol/L citrate buffer, pH 2.5, containing 20 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD) and +30 kV voltage. The detection limit was 2.5 x 10(-10) mol/L. This method allows the in vivo brain monitoring of 5-HT using a simple, accurate CE measurement in underivatized microdialysis samples.

  8. Breakup of Bubbles or Drops by Capillary Waves Induced by Coalescence or Other Excitations

    Science.gov (United States)

    Zhang, Feng Hua; Taborek, Peter; Burton, Justin; Cheong Khoo, Boo; Thoroddsen, Siggi

    2012-02-01

    Capillary breakup of a bubble or drop by various excitations is ubiquitous in both nature and technology. Examples include coalescence with another bubble or drop, wetting on a solid surface, impact on a solid surface, detachment from a nozzle, or vibrations driven by acoustic, electrical, or magnetic fields. When the excitation ceases, capillary forces on the surface naturally drive the deformed bubble or drop to recover its spherical shape. However, when the viscosity is small, this recovery can lead to nonlinear oscillations of the interface and a singularity in the flow. Here we use high-speed imaging to investigate the coalescence of bubbles and drops of various sizes. In many cases, coalescence leads to pinch-off events and the formation of the satellite and sub-satellite. Our experiments use pressured xenon gas in glycerol/water mixtures so that the density ratio and viscosity ratio can be varied over many orders of magnitude. We characterize the generation, propagation, and convergence of capillary waves, the formation time and sizes of satellites, and the dynamics of two-fluid pinch-off as a function of the density ratio and viscosity ratio. The work shall benefit the wide-spread applications and fulfill the scientific and public curiosities.

  9. Analysis of the anti-Parkinson drug pramipexole in human urine by capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Musenga, Alessandro; Kenndler, Ernst; Morganti, Emanuele; Rasi, Fabrizio; Raggi, Maria Augusta

    2008-09-19

    A sensitive method based on capillary electrophoresis with laser-induced fluorescence detection has been developed for the analysis of the non-ergoline dopamine agonist pramipexole in human urine. Separation was carried out in uncoated fused silica capillaries (75microm internal diameter, 75.0 and 60.0cm total and effective length, respectively), with a background electrolyte composed of borate buffer (50mM, pH 10.3), tetrabutylammonium bromide (30mM), and acetone (15%, v/v). Applying a 20kV voltage, the electrophoretic run is completed within 12min. A sample pre-treatment procedure based on liquid/liquid extraction with ethyl acetate, followed by derivatisation of pramipexole with fluorescein isothiocyanate at pH 9, allows the complete removal of biological interferences, with extraction yields always higher than 94.5%. Method validation gave good linearity (r(2)=0.9992) in the 25.0-1000ngmL(-1) range; limit of detection and limit of quantitation were 10.0 and 25.0ngmL(-1), respectively; precision was 90.0. The method was applied to the analysis of urine samples from patients undergoing therapy with pramipexole.

  10. Analysis of red inks by micellar electrokinetic capillary chromatography with laser-induced fluorescence detection.

    Science.gov (United States)

    Król, Małgorzata; Gondko, Klaudia; Kula, Agnieszka; Kościelniak, Paweł

    2016-01-01

    A combination of MEKC with a--highly sensitive but not commonly used--LIF detector was tested regarding the possibility of differentiation of red inks. The separation process was conducted in a fused silica capillary (id 50 μm, 60/50 cm total/effective length) in BGE consisting of 40 mM sodium borate, 20 mM SDS and 10% v/v ACN with 30 kV applied. The optimized temperature of storage and capillary was 10 and 25°C, respectively. The samples were prepared using 20 dots (ø 0.5 mm), extracted in 35 μL BGE and diluted with 30 μL of water. The proposed method showed excellent repeatability and reproducibility (RSD (tm ) < 0.8 and < 2.5%, respectively). It was applied to group identification and differentiation of different brands, models, and batches of red printing, stamp, and pen inks. It was demonstrated that differentiation can be performed effectively on the basis of migration times and ratios of peak areas. The high efficiency of the developed method was indicated by discriminating power ranging from 87.3 to 98.8%, for stamp and pen inks, respectively. The results showed that the proposed procedure can be valuable for an objective examination of the red parts of questioned documents.

  11. High-Throughput Analysis With 96-Capillary Array Electrophoresis and Integrated Sample Preparation for DNA Sequencing Based on Laser Induced Fluorescence Detection

    Energy Technology Data Exchange (ETDEWEB)

    Gang Xue

    2001-12-31

    The purpose of this research was to improve the fluorescence detection for the multiplexed capillary array electrophoresis, extend its use beyond the genomic analysis, and to develop an integrated micro-sample preparation system for high-throughput DNA sequencing. The authors first demonstrated multiplexed capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) separations in a 96-capillary array system with laser-induced fluorescence detection. Migration times of four kinds of fluoresceins and six polyaromatic hydrocarbons (PAHs) are normalized to one of the capillaries using two internal standards. The relative standard deviations (RSD) after normalization are 0.6-1.4% for the fluoresceins and 0.1-1.5% for the PAHs. Quantitative calibration of the separations based on peak areas is also performed, again with substantial improvement over the raw data. This opens up the possibility of performing massively parallel separations for high-throughput chemical analysis for process monitoring, combinatorial synthesis, and clinical diagnosis. The authors further improved the fluorescence detection by step laser scanning. A computer-controlled galvanometer scanner is adapted for scanning a focused laser beam across a 96-capillary array for laser-induced fluorescence detection. The signal at a single photomultiplier tube is temporally sorted to distinguish among the capillaries. The limit of detection for fluorescein is 3 x 10{sup -11} M (S/N = 3) for 5-mW of total laser power scanned at 4 Hz. The observed cross-talk among capillaries is 0.2%. Advantages include the efficient utilization of light due to the high duty-cycle of step scan, good detection performance due to the reduction of stray light, ruggedness due to the small mass of the galvanometer mirror, low cost due to the simplicity of components, and flexibility due to the independent paths for excitation and emission.

  12. High-Throughput Analysis With 96-Capillary Array Electrophoresis and Integrated Sample Preparation for DNA Sequencing Based on Laser Induced Fluorescence Detection

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Gang [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    The purpose of this research was to improve the fluorescence detection for the multiplexed capillary array electrophoresis, extend its use beyond the genomic analysis, and to develop an integrated micro-sample preparation system for high-throughput DNA sequencing. The authors first demonstrated multiplexed capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) separations in a 96-capillary array system with laser-induced fluorescence detection. Migration times of four kinds of fluoresceins and six polyaromatic hydrocarbons (PAHs) are normalized to one of the capillaries using two internal standards. The relative standard deviations (RSD) after normalization are 0.6-1.4% for the fluoresceins and 0.1-1.5% for the PAHs. Quantitative calibration of the separations based on peak areas is also performed, again with substantial improvement over the raw data. This opens up the possibility of performing massively parallel separations for high-throughput chemical analysis for process monitoring, combinatorial synthesis, and clinical diagnosis. The authors further improved the fluorescence detection by step laser scanning. A computer-controlled galvanometer scanner is adapted for scanning a focused laser beam across a 96-capillary array for laser-induced fluorescence detection. The signal at a single photomultiplier tube is temporally sorted to distinguish among the capillaries. The limit of detection for fluorescein is 3 x 10-11 M (S/N = 3) for 5-mW of total laser power scanned at 4 Hz. The observed cross-talk among capillaries is 0.2%. Advantages include the efficient utilization of light due to the high duty-cycle of step scan, good detection performance due to the reduction of stray light, ruggedness due to the small mass of the galvanometer mirror, low cost due to the simplicity of components, and flexibility due to the independent paths for excitation and emission.

  13. Capillary electrophoresis with laser-induced fluorescence detection for studying amino acid uptake by yeast during beer fermentation.

    Science.gov (United States)

    Turkia, Heidi; Sirén, Heli; Penttilä, Merja; Pitkänen, Juha-Pekka

    2015-01-01

    The amino acid composition of cultivation broth is known to affect the biomass accumulation, productivity, and vitality of yeast during cultivation. A separation method based on capillary electrophoresis with laser-induced fluorescence (LIF) detection was developed for the determination of amino acid consumption by Saccharomyces cerevisiae during beer fermentation. Intraday relative standard deviations were less than 2.1% for migration times and between 2.9% and 9.9% for peak areas. Interday relative standard deviations were less than 2.5% for migration times and between 4.4% and 18.9% for peak areas. The quantification limit was even as low as 62.5 pM which equals to below attomole level detection. The method was applied to study the rate of amino acid utilization during beer fermentation.

  14. Carboxymethyl-β-cyclodextrin for Chiral Separation of Amino Acids Derivatized with Fluorescene-5-isothiocyanate by Capillary Electrophoresis and Laser-induced Fluorescence Detection

    Institute of Scientific and Technical Information of China (English)

    Yu Yun CHEN; Wei WANG; Wei Ping YANG; Zhu Jun ZHANG

    2004-01-01

    A method using carboxymethyl-β-cyclodextrin(CM-β-CD) as selector for chiral separation of amino acids by capillary electrophoresis and laser-induced fluorescence detection was studied. Resolution was better than that obtained byβ-CD or HP-β-CD.

  15. Determination of Amino Acids in an Individual Erythrocyteby Capillary Electrophoresis with Intracellular FITC-derivatization and Laser-induced Fluorescence Detection

    Institute of Scientific and Technical Information of China (English)

    Hua ZHANG; Wen Rui JIN

    2003-01-01

    A novel approach for analysis of amino acids in individual erythrocytes was established.In this method, the derivatization reagent was introduced into the living cells by electroporation.After derivatization, the amino acids in a single cell were determined by capillary electrophoresiswith laser-induced fluorescence detection.

  16. Tumor endothelial marker 5 expression in endothelial cells during capillary morphogenesis is induced by the small GTPase Rac and mediates contact inhibition of cell proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Vallon, Mario, E-mail: m.vallon@arcor.de [Nuklearmedizinische Klinik und Poliklinik, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Rohde, Franziska; Janssen, Klaus-Peter [Chirurgische Klinik und Poliklinik, Technische Universitaet Muenchen, Munich (Germany); Essler, Markus [Nuklearmedizinische Klinik und Poliklinik, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany)

    2010-02-01

    Tumor endothelial marker (TEM) 5 is an adhesion G-protein-coupled receptor upregulated in endothelial cells during tumor and physiologic angiogenesis. So far, the mechanisms leading to upregulation of TEM5 and its function during angiogenesis have not been identified. Here, we report that TEM5 expression in endothelial cells is induced during capillary-like network formation on Matrigel, during capillary morphogenesis in a three-dimensional collagen I matrix, and upon confluence on a two-dimensional matrix. TEM5 expression was not induced by a variety of soluble angiogenic factors, including VEGF and bFGF, in subconfluent endothelial cells. TEM5 upregulation was blocked by toxin B from Clostridium difficile, an inhibitor of the small GTPases Rho, Rac, and Cdc42. The Rho inhibitor C3 transferase from Clostridium botulinum did not affect TEM5 expression, whereas the Rac inhibitor NSC23766 suppressed TEM5 upregulation. An excess of the soluble TEM5 extracellular domain or an inhibitory monoclonal TEM5 antibody blocked contact inhibition of endothelial cell proliferation resulting in multilayered islands within the endothelial monolayer and increased vessel density during capillary formation. Based on our results we conclude that TEM5 expression during capillary morphogenesis is induced by the small GTPase Rac and mediates contact inhibition of proliferation in endothelial cells.

  17. Prenatal hypoxia induces increased cardiac contractility on a background of decreased capillary density

    Directory of Open Access Journals (Sweden)

    Ousley Victoria

    2009-01-01

    Full Text Available Abstract Background Chronic hypoxia in utero (CHU is one of the most common insults to fetal development and may be associated with poor cardiac recovery from ischaemia-reperfusion injury, yet the effects on normal cardiac mechanical performance are poorly understood. Methods Pregnant female wistar rats were exposed to hypoxia (12% oxygen, balance nitrogen for days 10–20 of pregnancy. Pups were born into normal room air and weaned normally. At 10 weeks of age, hearts were excised under anaesthesia and underwent retrograde 'Langendorff' perfusion. Mechanical performance was measured at constant filling pressure (100 cm H2O with intraventricular balloon. Left ventricular free wall was dissected away and capillary density estimated following alkaline phosphatase staining. Expression of SERCA2a and Nitric Oxide Synthases (NOS proteins were estimated by immunoblotting. Results CHU significantly increased body mass (P in utero. Conclusion These data offer potential mechanisms for poor recovery following ischaemia, including decreased coronary flow reserve and impaired angiogenesis with subsequent detrimental effects of post-natal cardiac performance.

  18. Vocal nodules and edema may be due to vibration-induced rises in capillary pressure.

    Science.gov (United States)

    Czerwonka, Lukasz; Jiang, Jack J; Tao, Chao

    2008-04-01

    Vocal fold vibration may physically raise intravascular pressure to levels high enough to damage capillaries and result in leakage of erythrocytes. This type of injury is commonly seen in benign vocal fold lesions and is not well explained. Theoretical, retrospective. The relationship of intravascular pressure to vibration frequency and amplitude is derived and confirmed with a physical blood vessel model, then applied to published human measurements to estimate human intravascular pressures. Vocal fold intravascular pressure is predicted to have a quadratic dependence on both frequency and amplitude. During speaking, the pressure may rise to over 20 cmH2O, and may reach levels far higher for screaming and singing. Such pressure magnitudes are known to trigger inflammatory cascades and can lead to fluid leakage. They also have the potential for pharmacologic control with beta-agonists. Intravascular pressure likely rises significantly during vocal fold vibration and may lead to the type of injury seen in benign vocal fold lesions. The results support voice therapy aimed at reducing vibratory amplitude. More vibratory amplitude measurements need to be performed in a wider range of subjects before the full range of human vocal fold vascular pressures can be estimated.

  19. Simultaneous determination of vigabatrin and amino acid neurotransmitters in brain microdialysates by capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Benturquia, Nadia; Parrot, Sandrine; Sauvinet, Valérie; Renaud, Bernard; Denoroy, Luc

    2004-07-01

    Capillary electrophoresis with laser-induced fluorescence detection (CE-LIFD) coupled to in vivo microdialysis sampling was used in order to monitor simultaneously a drug and several neurotransmitters in the brain extracellular fluid. Determination of the antiepileptic drug vigabatrin and the amino acid neurotransmitters glutamate (Glu), l-aspartate (l-Asp) and gamma-aminobutyric acid (GABA) was performed on low-concentration samples which were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and separated using a pH 9.2 75 mM sodium borate running buffer containing 60 mM sodium dodecyl sulfate (SDS) and 5mM hydroxypropyl-beta-cyclodextrin (HP-beta-CD). Glu, l-Asp and vigabatrin derivatized at a concentration of 1.0 x 10(-9) M, and GABA derivatized at a concentration of 5.0 x 10(-9) M, produced peaks with signal-to-noise ratios of 8:1, 8:1, 4:1 and 5:1, respectively. The nature of the neurotransmitter peaks found in rat brain microdialysates was confirmed by both electrophoretic and pharmacological validations. This method was used for monitoring vigabatrin and amino acid neurotransmitters in microdialysates from the rat striatum during intracerebral infusion of the drug and revealed rapid vigabatrin-induced changes in GABA and Glu levels. This original application of CE-LIFD coupled to microdialysis represents a powerful tool for pharmacokinetic/pharmacodynamic investigations.

  20. Fluctuations and Stimulus-Induced Changes in Blood Flow Observed in Individual Capillaries in Layers 2 through 4 of Rat Neocortex

    Science.gov (United States)

    Kleinfeld, David; Mitra, Partha P.; Helmchen, Fritjof; Denk, Winfried

    1998-12-01

    Cortical blood flow at the level of individual capillaries and the coupling of neuronal activity to flow in capillaries are fundamental aspects of homeostasis in the normal and the diseased brain. To probe the dynamics of blood flow at this level, we used two-photon laser scanning microscopy to image the motion of red blood cells (RBCs) in individual capillaries that lie as far as 600 μ m below the pia mater of primary somatosensory cortex in rat; this depth encompassed the cortical layers with the highest density of neurons and capillaries. We observed that the flow was quite variable and exhibited temporal fluctuations around 0.1 Hz, as well as prolonged stalls and occasional reversals of direction. On average, the speed and flux (cells per unit time) of RBCs covaried linearly at low values of flux, with a linear density of ≈ 70 cells per mm, followed by a tendency for the speed to plateau at high values of flux. Thus, both the average velocity and density of RBCs are greater at high values of flux than at low values. Time-locked changes in flow, localized to the appropriate anatomical region of somatosensory cortex, were observed in response to stimulation of either multiple vibrissae or the hindlimb. Although we were able to detect stimulus-induced changes in the flux and speed of RBCs in some single trials, the amplitude of the stimulus-evoked changes in flow were largely masked by basal fluctuations. On average, the flux and the speed of RBCs increased transiently on stimulation, although the linear density of RBCs decreased slightly. These findings are consistent with a stimulus-induced decrease in capillary resistance to flow.

  1. Intense pulsed light therapy (IPL) induced iritis following treatment for a medial canthal capillary malformation.

    Science.gov (United States)

    Crabb, Matthew; Chan, Weng Onn; Taranath, Deepa; Huilgol, Shyamala C

    2014-11-01

    The popularity of intense pulsed light (IPL) therapy continues to increase due to its relative safety, high skin coverage rate and ability to treat both vascular and pigmented lesions. An often-overlooked risk is the potential for IPL-induced ocular damage. The damage sustained can cause significant, persistent morbidity and can occur even with very limited IPL exposure to the eye.

  2. Separation and quantitation of phycobiliproteins using phytic acid in capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Viskari, Pertti J; Colyer, Christa L

    2002-10-01

    The similar electrophoretic mobilities and sizes of several of the phycobiliproteins, which are derived from the photosynthetic apparatus of cyanobacteria and eukaryotic algae, render their separation and quantitation a challenging problem. However, we have developed a suitable capillary electrophoresis (CE) method that employs a phytic acid-boric acid buffer and laser-induced fluorescence (LIF) detection with a single 594 nm He-Ne laser. This method takes advantage of the remarkably high quantum yields of these naturally fluorescent proteins, which can be attributed to their linear tetrapyrrole chromophores covalently bound to cysteinyl residues. As such, limits of detection of 1.18 x 10(-14), 5.26 x 10(-15), and 2.38 x 10(-15) mol/l were obtained for R-phycoerythrin, C-phycocyanin, and allophycocyanin proteins, respectively, with a linear dynamic range of eight orders of magnitude in each case. Unlike previously published CE-LIF methods, this work describes the separation of all three major classes of phycobiliproteins in under 5 min. Very good recoveries, ranging from 93.2 to 105.5%, were obtained for a standard mixture of the phycobiliproteins, based on seven-point calibration curves for both peak height and peak area. It is believed that this development will prove useful for the determination of phycobiliprotein content in naturally occurring cyanobacteria populations, thus providing a useful tool for understanding biological and chemical oceanographic processes.

  3. Determination of intracellular levels of 6-mercaptopurine metabolites in erythrocytes utilizing capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Rabel, S R; Stobaugh, J F; Trueworthy, R

    1995-01-01

    Capillary electrophoresis proved to be a useful technique for the analysis of intracellular levels of 6-thioguanosine mono-, di-, and triphosphate with analysis times of 20 min. Conditions required for baseline separation of the thioguanine nucleotides consisted of a 25 mM KH2PO4 (pH 8.0) buffer and a separation voltage of +28 kV. Laser-induced fluorescence detection (lambda ex = 325 nm, lambda em = 410 nm) of the thioguanine nucleotide metabolites of 6-mercaptopurine (6-MP) was possible following oxidation of the thiol functionality. Tedious extraction procedures involving mercury cellulose resins or phenyl mercury adduct formation, which had been required previously for the selective extraction of thiopurines from erythrocytes, were unnecessary due to the overall specificity of the approach. However, the inclusion of 50 mM EDTA in the sample preparation was required to inhibit the anabolic/catabolic enzymatic activity, which was responsible for the degradation of the analytes. The method demonstrated linearity from 5 to 1700 pmol/100 microliters red blood cells for the three analytes (RSDs < or = 8%). The feasibility of the method was demonstrated for the quantitation of 6-thioguanine nucleotides in patients receiving either oral or intravenous 6-MP therapy.

  4. Amine Analysis Using AlexaFluor 488 Succinimidyl Ester and Capillary Electrophoresis with Laser-Induced Fluorescence

    Directory of Open Access Journals (Sweden)

    Christian G. Kendall

    2015-01-01

    Full Text Available Fluorescent probes enable detection of otherwise nonfluorescent species via highly sensitive laser-induced fluorescence. Organic amines are predominantly nonfluorescent and are of analytical interest in agricultural and food science, biomedical applications, and biowarfare detection. Alexa Fluor 488 N-hydroxysuccinimidyl ester (AF488 NHS-ester is an amine-specific fluorescent probe. Here, we demonstrate low limit of detection of long-chain (C9 to C18 primary amines and optimize AF488 derivatization of long-chain primary amines. The reaction was found to be equally efficient in all solvents studied (dimethylsulfoxide, ethanol, and N,N-dimethylformamide. While an organic base (N,N-diisopropylethylamine is required to achieve efficient reaction between AF488 NHS-ester and organic amines with longer hydrophobic chains, high concentrations (>5 mM result in increased levels of ethylamine and propylamine in the blank. Optimal incubation times were found to be >12 hrs at room temperature. We present an initial capillary electrophoresis separation for analysis using a simple micellar electrokinetic chromatography (MEKC buffer consisting of 12 mM sodium dodecylsulfate (SDS and 5 mM carbonate, pH 10. Limits of detection using the optimized labeling conditions and these separation conditions were 5–17 nM. The method presented here represents a novel addition to the arsenal of fluorescent probes available for highly sensitive analysis of small organic molecules.

  5. Simultaneous Determination of Levodopa and Its Metabolite in Human Blood by Capillary Electrophoresis with Laser-induced Fluorescence Detection

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ying-Xue; ZHANG Zhu-Jun; YANG Feng

    2008-01-01

    A rapid, sensitive and reproducible method is described for the analysis of levodopa and its metabolite dopamine (DA) in human blood. The influence of carbidopa as the inhibitor againist the decarboxylase activity on the metabolism has been also studied. After derivatization in a dark pulsator for 12 h at room temperature, the fluorescein isothiocyanate (FITC) derivative of levodopa and other components were separated by capillary zone electrophoresis (CZE) within 13 min and detected with laser-induced fluorescence (LIF). Under the optimum analysis conditions, the linear range is 3.0×10-8-4.0×10-6 mol/L and 1.0×10-8-2.0×10-6 mol/L for levodopa and DA,respectively. The detection limits of levodopa and DA were 7.8×10-9 mol/L (39.0 amol) and 3.1×10-9 mol/L(15.5 amol), respectively. The method was successfully applied to monitoring the levodopa and DA in human blood after one took tablets orally.

  6. Anti-lipid phosphate phosphohydrolase-3 (LPP3 antibody inhibits bFGF- and VEGF-induced capillary morphogenesis of endothelial cells

    Directory of Open Access Journals (Sweden)

    Humtsoe Joseph O

    2005-08-01

    Full Text Available Abstract Background Angiogenesis, or the remodeling of existing vasculature serves as a lifeline to nourish developing embryos and starved tissues, and to accelerate wound healing, diabetic retinopathy, and tumor progression. Recent studies indicate that angiogenesis requires growth factor activity as well as cell adhesion events mediated by α5β1 and αvβ3 integrins. We previously demonstrated that human lipid phosphate phosphohydrolase-3 (LPP3 acts as a cell-associated ligand for α5β1 and αvβ3 integrins. Here, we test the hypothesis that an anti-LPP3 antibody can inhibit basic fibroblast growth factor (bFGF-and vascular endothelial growth factor (VEGF-induced capillary morphogenesis of endothelial cells (ECs. Results We report that bFGF and VEGF up-regulate LPP3 protein expression in ECs. Immunoprecipitation analyses show that LPP3 is a cell surface protein and undergoes N-glycosylation. Fluorescent activated cell sorting (FACS data suggest that anti-LPP3-RGD detects native neoepitope on the surface of activated ECs. Moreover, we demonstrate LPP3 protein expression in tumor endothelium alongside VEGF. The embedding of ECs into three-dimensional type I collagen in the presence of bFGF and VEGF induce capillary formation. Importantly, we show that the addition of an anti-LPP3 antibody specifically and significantly blocks bFGF- and VEGF-induced capillary morphogenesis of ECs. Conclusion These data suggest that activated ECs as well as tumor endothelium express LPP3 protein. In an in vitro assay, the anti-LPP3-RGD specifically blocks bFGF and VEGF induced capillary morphogenesis of ECs. Our results, therefore, suggest a role for LPP3 in angiogenesis.

  7. Impaired training-induced adaptation of blood pressure in COPD patients: implication of the muscle capillary bed

    Directory of Open Access Journals (Sweden)

    Gouzi F

    2016-09-01

    Full Text Available Fares Gouzi,1,2 Jonathan Maury,1,3 François Bughin,1,2 Marine Blaquière,1,2 Bronia Ayoub,1,2 Jacques Mercier,1,2 Antonia Perez-Martin,4,5 Pascal Pomiès,1 Maurice Hayot1,2 1PhyMedExp, INSERM U1046, CNRS UMR 9214, University of Montpellier, 2Department of Clinical Physiology, Montpellier University Hospital, Montpellier, 3Pulmonary Rehabilitation Center “La Solane”, 5 Santé Group, Osséja, 4Dysfunction of Vascular Interfaces Laboratory, EA 2992, University of Montpellier, 5Department of Vascular Medicine and Investigations, Nîmes University Hospital, Nîmes, France Background and aims: Targeting the early mechanisms in exercise-induced arterial hypertension (which precedes resting arterial hypertension in its natural history may improve cardiovascular morbidity and mortality in COPD patients. Capillary rarefaction, an early event in COPD before vascular remodeling, is a potential mechanism of exercise-induced and resting arterial hypertension. Impaired training-induced capillarization was observed earlier in COPD patients; thus, this study compares the changes in blood pressure (BP during exercise in COPD patients and matches control subjects (CSs after a similar exercise training program, in relationship with muscle capillarization. Methods: Resting and maximal exercise diastolic pressure (DP and systolic pressure (SP were recorded during a standardized cardiopulmonary exercise test, and a quadriceps muscle biopsy was performed before and after training.Results: A total of 35 CSs and 49 COPD patients (forced expiratory volume in 1 second=54%±22% predicted completed a 6-week rehabilitation program and improved their symptom-limited maximal oxygen uptake (VO2SL: 25.8±6.1 mL/kg per minute vs 27.9 mL/kg per minute and 17.0±4.7 mL/kg per minute vs 18.3 mL/kg per minute; both P<0.001. The improvement in muscle capillary-to-fiber (C/F ratio was significantly greater in CSs vs COPD patients (+11%±9% vs +23%±21%; P<0.05. Although maximal

  8. Capillary-driven microfluidic chips with evaporation-induced flow control and dielectrophoretic microbead trapping

    Science.gov (United States)

    Temiz, Yuksel; Skorucak, Jelena; Delamarche, Emmanuel

    2014-07-01

    This work reports our efforts on developing simple-to-use microfluidic devices for point-of-care diagnostic applications with recent extensions that include the trapping of microbeads using dielectrophoresis (DEP) and the modulation of the liquid flow using integrated microheaters. DEP serves the purpose of trapping microbeads coated with receptors and analytes for detection of a fluorescent signal. The microheater is actuated once the chip is filled by capillarity, creating an evaporation-induced flow tuned according to assay conditions. The chips are composed of a glass substrate patterned with 50-nm-thick Pd electrodes and microfluidic structures made using a 20-μm-thick dry-film resist (DFR). Chips are covered/sealed by low temperature (50°C) lamination of a 50-μm-thick DFR layer having excellent optical and mechanical properties. To separate cleaned and sealed chips from the wafer, we used an effective chip singulation technique which we informally call the "chip-olate" process. In the experimental section, we first studied dielectrophoretic trapping of 10-μm beads for flow rates ranging from 80 pL s-1 to 2.5 nL s-1 that are generated by an external syringe pump. Then, we characterized the embedded microheater in DFR-covered chips. Flow rates as high as 8 nL s-1 were generated by evaporation-induced flow when the heater was biased by 10 V, corresponding to 270-mW power. Finally, DEP-based trapping and fluorescent detection of functionalized beads were demonstrated as the flow was generated by evaporation-induced flow after the microfluidic structures were filled by capillarity.

  9. Laser-induced capillary effect in thin layers of water-alcohol mixtures.

    Science.gov (United States)

    Ivanova, Natalia A; Tatosov, Aleksey V; Bezuglyi, Boris A

    2015-06-01

    The effect of droplet formation in thin layers of water-alcohol mixtures upon laser heating was studied. The droplet growth in the laser beam is governed by the surface tension gradient, which induces solutocapillary flows from the periphery to the center of the heated area. This gradient arises due to the local increase in surface tension caused by the evaporation of alcohol from the heated area of the layer. The experimental results have shown that the increase in the initial concentration of water in the mixture gives rise to the increase in droplet size. However, the increase in the power of laser irradiation leads to a decrease in the droplet growth rate. A simplified one-dimensional model of droplet growth is developed. The model involves the dependence of surface tension on both the temperature and concentration of components in the mixture, as well as the evaporation and condensation of alcohol. The experimental results are compared with those obtained using numerical simulations. A reasonable agreement between experimental and numerical results was shown.

  10. Plasma protein induced clustering of red blood cells in micro capillaries

    Science.gov (United States)

    Wagner, Christian; Brust, Mathias; Aouane, Othmane; Flormann, Daniel; Thiebaud, Marine; Verdier, Claude; Coupier, Gwennou; Podgorski, Thomas; Misbah, Chaouqi; Selmi, Hassib

    2013-11-01

    The plasma molecule fibrinogen induces aggregation of RBCs to clusters, the so called rouleaux. Higher shear rates in bulk flow can break them up which results in the pronounced shear thinning of blood. This led to the assumption that rouleaux formation does not take place in the microcapillaries of the vascular network where high shear rates are present. However, the question is of high medical relevance. Cardio vascular disorders are still the main cause of death in the western world and cardiac patients have often higher fibrinogen level. We performed AFM based single cell force spectroscopy to determine the work of separation. Measurements at low hematocrit in a microfluidic channel show that the number of size of clusters is determined by the adhesion strength and we found that cluster formation is strongly enhanced by fibrinogen at physiological concentrations, even at shear rate as high as 1000 1/s. Numerical simulations based on a boundary integral method confirm our findings and the clustering transition takes place both in the experiments and in the simulations at the same interaction energies. In vivo measurements with intravital fluorescence microscopy in a dorsal skin fold chamber in a mouse reveal that RBCs indeed form clusters in the micrcapillary flow. This work was supported by the German Science Foundation research imitative SFB1027.

  11. Light-emitting diode induced fluorescence (LED-IF) detection design for a pen-shaped cartridge based single capillary electrophoresis system.

    Science.gov (United States)

    Kerékgyártó, Márta; Kerekes, Tamás; Tsai, Eric; Amirkhanian, Varoujan D; Guttman, András

    2012-09-01

    CGE is a well-established separation technique for the analysis of biologically important molecules such as nucleic acids. The inherent high resolving power, rapid analysis times, excellent detection sensitivity, and quantification capabilities makes this method favorable compared to conventional manual polyacrylamide and agarose slab gel electrophoresis techniques. In this paper we introduce a novel single-channel capillary gel electrophoresis system with LED-induced fluorescence detection also utilizing a compact pen-shaped capillary cartridge design for automatic analysis of samples from a 96-well plate. To evaluate the suitability of the system, 1000 genomic DNA(gDNA) samples were analyzed in gel filled capillaries and detected by the microball ended excitation and emission optical fiber based LED-induced fluorescence detection system. Excellent migration time reproducibility of RSD <0.75% was obtained over the course of 1000 runs. The system rapidly distinguished between intact and degraded gDNA samples, therefore provided important information if they could be used for downstream quantitative PCR processing where high-quality intact gDNA was key. We envision that this novel system design will rapidly find new applications in both research and clinical diagnostic laboratories as a highly sensitive and easy to use bio-analytical approach.

  12. The analysis of fountain pen inks by capillary electrophoresis with ultraviolet/visible absorbance and laser-induced fluorescence detection.

    Science.gov (United States)

    Rohde, E; Vogt, C; Heineman, W R

    1998-01-01

    Information on the identity of inks adds to the circumstantial evidence in legal cases involving fraudulent documents. In combination with optical methods, multiple thin-layer chromatography (TLC) is currently the analytical tool used by forensic chemists to separate, compare and distinguish inks based on their dye composition. In our studies, capillary electrophoresis (CE) was used for the analysis of water-soluble fountain pen inks. Inks are complex mixtures of synthetic organic and inorganic dyes, surfactants, resins and other components. The investigations included the development of an electrophoretic separation method, the optimization of an extraction procedure for inks from paper as well as the evaluation of ultraviolet/visible (UV/VIS) absorbance and laser-induced fluorescence (LIF) detection for the analysis of inks by CE. Good results for the separation of 17 blue and black inks of different manufacturers and countries of origin were obtained with 100 mM borate buffer, pH 8.0, containing 20% methanol. The electropherograms of the inks and their extracts from paper showed patterns that were in most cases distinctly different from each other. Ultraviolet/visible scans can be used to compare spectra of the separated main and trace components of inks. Fluorescence detection at different excitation and emission wavelengths was more sensitive, but added to the complexity of the electropherograms due to the excitation of coextracted fluorescing paper components. The resolution power of CE combined with the information content provided by the detection modes investigated prove CE to be a powerful tool for the identification of water-soluble inks used on paper documents.

  13. Simultaneous detection of ultraviolet B-induced DNA damage using capillary electrophoresis with laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Guthrie, Jeffrey W., E-mail: jeff.guthrie@emich.edu; Limmer, Robert T.; Brooks, Eric A.; Wisnewski, Chelsea C.; Loggins-Davis, Nnekia D.; Bouzid, Abderraouf

    2015-01-01

    Highlights: • CE–LIF was developed for simultaneous detection of UV-induced DNA photoproducts. • Fluorescent quantum dot reporters enabled detection of small amounts of photoproducts. • Photoproducts were detected after 65 J m{sup −2} of fluence from a UVB lamp in ∼6 ng of DNA. • Natural sunlight induced cyclobutane pyrimidine dimers after only 15 min of exposure. - Abstract: An immunoassay based on CE–LIF was developed for the simultaneous detection of cyclobutane pyrimidine dimers (CPDs) and pyrimidine 6-4 pyrimidone photoproducts (6-4PPs) in genomic DNA irradiated with UVB or natural sunlight. Human cells were first exposed to varying amounts of UVB or natural sunlight to induce DNA damage. Genomic DNA was extracted and incubated with anti-CPD and anti-6-4PP primary antibodies attached to secondary antibodies with a fluorescent quantum dot (QD) reporter that emitted either red or yellow fluorescence. CE was used to separate the unbound antibodies from those bound to the photoproducts, and LIF with appropriate optical filters was used to separate the fluorescence signals from each QD to individual photomultiplier tubes for simultaneous photoproduct detection. Using this strategy, photoproducts were detected from ∼6 ng (200 ng μL{sup −1}) of DNA under a low UVB fluence of 65 J m{sup −2} for CPDs or 195 J m{sup −2} for 6-4PPs. This assay was also the first to demonstrate the detection of CPDs in human cells after only 15 min of irradiation under natural sunlight.

  14. Obesity Downregulates MicroRNA-126 Inducing Capillary Rarefaction in Skeletal Muscle: Effects of Aerobic Exercise Training

    Science.gov (United States)

    Fernandes, Tiago; Soci, Ursula Paula Reno; Silveira, André Casanova; Barretti, Diego Lopes Mendes; Negrão, Carlos Eduardo

    2017-01-01

    Background. We investigated the effects of exercise training (ET) on miR-126 levels and skeletal muscle angiogenesis in obese Zucker rats. Results. Zucker rats were randomly assigned to sedentary and swimming-trained groups: lean sedentary (LS) and trained (LTR); obese sedentary (OB) and trained (OBTR). The OB group displayed capillary rarefaction compared with the LS group. In contrast, ET increased the capillary/fiber ratio by 38% in the LTR group and normalized capillary rarefaction in the OBTR group. VEGF, PI3K, and eNOS levels were reduced in the skeletal muscle of the OB group. ET normalized VEGF, PI3K, and eNOS levels in OBTR, contributing to vascular network homeostasis. PI3KR2 inhibits PI3K, a key mediator of the VEGF signaling pathway. Obesity decreased miR-126 and increased PI3KR2 levels compared with the LS group. However, ET normalized miR-126 levels in the OBTR group versus the LS group and decreased expression of PI3KR2. Conclusion. Our findings show that obesity leads to skeletal muscle capillary rarefaction, which is regulated by decreased miR-126 levels and increased PI3KR2. Inversely, ET normalizes miR-126 levels and VEGF signaling and should be considered an important therapeutic strategy for vascular disorders.

  15. Applications of capillary electrophoresis and laser-induced fluorescence detection to the analysis of trace species: From single cells to single molecules

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Qifeng [Iowa State Univ., Ames, IA (United States)

    1995-09-26

    This Ph.D. Thesis describes several separation and detection schemes for the analysis of small volume and amount of samples, such as intracellular components and single enzymes developed during research. Indirect Laser-induced fluorescence detection and capillary electrophoresis were used to quantify lactate and pyruvate in single red blood cells. The assay of specific enzyme activities was achieved by monitoring the highly fluorescent enzymatic reaction product, NADH. LDH activity was found not to be a unique marker for diagnosis of leukemia. Reactions of single LDH-1 molecules were investigated by monitoring the reaction product with LIF detection.

  16. Applications of capillary electrophoresis and laser-induced fluorescence detection to the analysis of trace species: From single cells to single molecules

    Energy Technology Data Exchange (ETDEWEB)

    Qifeng, X.

    1995-11-01

    This Ph.D. Thesis describes several separation and detection schemes for the analysis of small volume and amount of samples, such as intracellular components and single enzymes developed during research. Indirect Laser-induced fluorescence detection and capillary electrophoresis were used to quantify lactate and pyruvate in single red blood cells. The assay of specific enzyme activities was achieved by monitoring the highly fluorescent enzymatic reaction product, NADH. LDH activity was found not to be a unique marker for diagnosis of leukemia. Reactions of single LDH-1 molecules were investigated by monitoring the reaction product with LIF detection.

  17. Nine orders of magnitude dynamic range: picomolar to millimolar concentration measurement in capillary electrophoresis with laser induced fluorescence detection employing cascaded avalanche photodiode photon counters.

    Science.gov (United States)

    Dada, Oluwatosin O; Essaka, David C; Hindsgaul, Ole; Palcic, Monica M; Prendergast, Jillian; Schnaar, Ronald L; Dovichi, Norman J

    2011-04-01

    The dynamic range of capillary electrophoresis analysis is ultimately limited by molecular shot noise at low concentrations and by concentration-induced band broadening at high concentrations. We report a system that approaches these fundamental limits. A laser-induced fluorescence detector is reported that employs a cascade of four fiber-optic beam splitters connected in series to generate a primary signal and four attenuated signals, each monitored by a single-photon counting avalanche photodiode. Appropriate scaling of the signals from the five photodiodes produces a linear optical calibration curve for 5-carboxyl-tetramethylrhodamine from the concentration detection limit of 1 pM to the upper limit of 1 mM. Mass detection limits are 120 yoctomoles (70 molecules) injected into the instrument. The very-wide dynamic range instrument was used to study the metabolic products of the fluorescently labeled glycosphingolipid tetramethylrhodamine labeled GM1 (GM1-TMR) produced by single cells isolated from the rat cerebellum.

  18. Leukocytes in capillary flow.

    Science.gov (United States)

    Schmid-Schönbein, G W; Lee, J

    1995-01-01

    During disease, the flow of blood cells through the capillary network is one of the most perilous events in the microcirculation. Capillary distensibility, cytoplasmic activity of endothelial cells, red cells and leukocytes play an important role in capillary perfusion. Occlusion of capillaries is one of the early signs of vascular failure and is encountered in many different conditions and organs. Adhesion of leukocytes to the endothelium via expression of membrane adhesion molecules leads to microvascular entrapment with capillary occlusion.

  19. [Analysis of difference of serum proteins between patients with cirrhosis and normal people by capillary electrophoresis with light-emitting diode induced fluorescence detection].

    Science.gov (United States)

    Bao, Rihuang; Fan, Qingjie; Song, Long; Yao, Yuan; Gao, Weiping

    2015-02-01

    An experimental method of protein separation by capillary electrophoresis coupled with light-emitting diode induced fluorescence detection (CE-LED-IF) was established. The fluorescein isothiocyanate (FITC) was used as fluorescent dye in this method. An optical fiber was inserted into the separation capillary and was suited right at the detection window which was used to transmit the excitation light of LED. The efficiency of the light of LED and the detection limits of FITC was improved. The difference of serum proteins between the patients with cirrhosis and normal people was detected by this method. A series of effects on CE were studied, such as the wavelength of the light source and filter, the concentration and pH of the running buffer and the separation voltage. Then the optimized method was established for the determination of the serum proteins. The repeatability of CE-LED-IF was tested and the RSDs of migration time and peak area were 1. 14% and 3. 23% , respectively. The results showed that there were two specific peaks in cirrhosis serum. The differences between the patients with cirrhosis and normal people having statistical significance indicated that these proteins might be the potential biomarkers for cirrhosis diagnosis. The developed CE-LED-IF method proved suitable for the separation of serum proteins with good repeatability and supportable for the clinical diagnosis of cirrhosis.

  20. Role of pigment epithelium-derived factor on proliferation and migration of choroidal capillary endothelium induced by vascular endothelial growth factor in vitro

    Institute of Scientific and Technical Information of China (English)

    WANG Feng-hua; SUN Xiao-dong; ZHANG Xi; XU Xun; ZHU Qi; HUANG Jian-nan; FAN Ying; GU Qing; LIU Hai-yang

    2007-01-01

    Background Pigment epithelium-derived factor (PEDF) is expressed in several normal organs and identified as an inhibitor of neovascularization. In the present study, we investigated the effect of PEDF in an in vitro model of ocular choroidal neovascularization.Methods Microdissection was used to isolate the human choroidal endothelial cells (CECs), followed by the use of superparamagnetic beads (Dynabeads) coated with the CD31 antibody, which selectively binds to the endothelial cell surface. The mitogenic and motogenic effects of vascular endothelial growth factor (VEGF) on cultured choroidal capillary endothelial cells were examined in the presence or absence of PEDF (1, 10, 100, and 1000 ng/ml) using cell counts and migration assays.Results Cells bound to the beads were isolated using a magnetic particle concentrator and they were successfully cultured and characterized to be endothelial cells that possessed greater than 95% immunoreactivity to von Willebrand factor. PEDF suppressed the proliferation and migration of VEGF-induced choroidal capillary endothelial cells. However,the concentration of PEDF which we used has little effect on normal CECs.Conclusions PEDF played an important role on the growth and migration of VEGF-stimulated choroidal endothelial cell.These findings suggest that PEDF may be an effective approach to the treatment of choroidal neovascular disorders.

  1. Fast capillary electrophoresis-laser induced fluorescence analysis of ligase chain reaction products: human mitochondrial DNA point mutations causing Leber's hereditary optic neuropathy.

    Science.gov (United States)

    Muth, J; Williams, P M; Williams, S J; Brown, M D; Wallace, D C; Karger, B L

    1996-12-01

    High speed capillary electrophoresis-laser-induced fluorescence (CE-LIF) has been used to separate and detect point mutations using the ligase chain reaction (LCR). The method utilizes short capillary columns (7.5 cm effective length) and fields of 400 V/cm to analyze DNA-ethidium bromide complexes using an He/Ne laser. The method was first demonstrated with a commercially available kit for LCR based on a lacI gene fragment inserted in a Bluescript II phagemid. LCR-CE-LIF was then applied to detect point mutations in human mitochondrial DNA, resulting in Leber's hereditary optic neuropathy (LHON). Three severe mutations were analyzed in which the original base is substituted by a thymidine base at positions 3460, 11778 and 14459. Appropriate primers were designed with polyT tails for length discrimination of pooled samples. Successful detection of mutated samples was achieved, with appropriate correction for small amounts of nonspecific ligated product. The method is rapid, easy to implement, and automatable.

  2. Enhanced pool boiling critical heat flux induced by capillary wicking effect of a Cr-sputtered superhydrophilic surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Son, Hong Hyun; Seo, Gwang Hyeok; Kim, Sung Joong [Hanyang University, Seoul (Korea, Republic of)

    2016-10-15

    In light of boiling heat transfer, the smooth surface potentially reduces active nucleation of bubbles and rewetting of dry spots near the critical heat flux (CHF). This kind of process is highly likely to deteriorate the CHF. Thus, it is essential to produce appropriate microstructures on the surface for the enhancement of the CHF. In this study, to investigate the microstructural effect of thin film-fabricated surfaces on the pool boiling CHF, we controlled the surface roughness in a narrow range of 0.1-0.25 μm and its morphologies, in the form of micro-scratches using PVD sputtering technique. Specifically for DC magnetron sputtering, pure chromium (Cr) was selected as a target material owing to its high oxidation resistance. In order to analyze the CHF trend with changes in roughness, we introduced existing capillary wicking-based models because superhydrophilic characteristics of microstructures are highly related to the capillary wicking behaviors in micro-flow channels. After Cr sputtering under given conditions, the Cr-sputtered surfaces showed superhydrophilic characteristics and its capability became more enhanced with an increase of surface roughness. Judging from spreading behavior of a liquid droplet, the presence of micro-wicking channels, coupled with Cr nanostructures, effectively enhanced the advancing rate of drop base diameter. The CHF exhibited an increasing trend with increasing surface roughness. However, the enhancement ratio agreed poorly with the predictions of the roughness factor-based models, all of which originated from a conventional static force balance.

  3. Detection of genetically modified maize by the polymerase chain reaction and capillary gel electrophoresis with UV detection and laser-induced fluorescence.

    Science.gov (United States)

    García-Cañas, Virginia; González, Ramón; Cifuentes, Alejandro

    2002-02-27

    In this paper, the possibilities of capillary gel electrophoresis (CGE) to detect transgenic maize in flours are shown. The method is based on the extraction and amplification by the polymerase chain reaction (PCR) of a specific DNA fragment from transgenic maize and its subsequent analysis by CGE with UV detection or laser-induced fluorescence (LIF). Some useful considerations regarding the optimization of DNA extraction and amplification conditions are given. Also, a comparison is established between the two CGE protocols for DNA detection based on ultraviolet absorption (CGE-UV) and LIF (CGE-LIF). The requirements, advantages, and limitations of both CGE methods are discussed. To our knowledge, this is the first paper on the use of CGE-LIF to detect transgenic food.

  4. Direct methods for dynamic monitoring of secretions from single cells by capillary electrophoresis and microscopy with laser-induced native fluorescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Tong, W.

    1997-10-08

    Microscale separation and detection methods for real-time monitoring of dynamic cellular processes (e.g., secretion) by capillary electrophoresis (CE) and microscopic imaging were developed. Ultraviolet laser-induced native fluorescence (LINF) provides simple, sensitive and direct detection of neurotransmitters and proteins without any derivatization. An on-column CE-LINF protocol for quantification of the release from single cell was demonstrated. Quantitative measurements of both the amount of insulin released from and the amount remaining in the cell ({beta}TC3) were achieved simultaneously. Secretion of catecholamines (norepinephrine (NE) and epinephrine (E)) from individual bovine adrenal chromaffin cells was determined using the on-column CE-LINF. Direct visualization of the secretion process of individual bovine adrenal chromaffin cells was achieved by LINF imaging microscopy with high temporal and spatial resolution. The secretion of serotonin from individual leech Retzius neurons was directly characterized by LINF microscopy with high spatial resolution.

  5. Direct methods for dynamic monitoring of secretions from single cells by capillary electrophoresis and microscopy with laser-induced native fluorescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Wei [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Microscale separation and detection methods for real-time monitoring of dynamic cellular processes (e.g., secretion) by capillary electrophoresis (CE) and microscopic imaging were developed. Ultraviolet laser-induced native fluorescence (LINF) provides simple, sensitive and direct detection of neurotransmitters and proteins without any derivatization. An on-column CE-LINF protocol for quantification of the release from single cell was demonstrated. Quantitative measurements of both the amount of insulin released from and the amount remaining in the cell (βTC3) were achieved simultaneously. Secretion of catecholamines (norepinephrine (NE) and epinephrine (E)) from individual bovine adrenal chromaffin cells was determined using the on-column CE-LINF. Direct visualization of the secretion process of individual bovine adrenal chromaffin cells was achieved by LINF imaging microscopy with high temporal and spatial resolution. The secretion of serotonin from individual leech Retzius neurons was directly characterized by LINF microscopy with high spatial resolution.

  6. Speciation of mercury in human whole blood by capillary gas chromatography with a microwave-induced plasma emission detector system following complexometric extraction and butylation.

    Science.gov (United States)

    Bulska, E; Emteborg, H; Baxter, D C; Frech, W; Ellingsen, D; Thomassen, Y

    1992-03-01

    Methyl- and inorganic mercury were extracted from human whole blood samples, as their diethyldithiocarbamate complexes, into toluene and butylated by using a Grignard reagent. The mercury species were then separated by gas chromatography (on a 12 m non-polar DB-1 capillary column) and detected by a microwave-induced plasma atomic emission spectrometric (GC-MPD) system. The accuracy and precision of the proposed method were established by the analysis of Seronorm lyophilized human whole blood standards for methyl- and inorganic mercury. No statistical difference (t-test) between the sum of these two species determined by the GC-MPD based method and the recommended total mercury concentrations in the Seronorm samples was observed. Results for the determination of methyl- and inorganic mercury in 60 controls and 90 previously occupationally exposed (to inorganic mercury) workers are presented to illustrate the practical utility of the proposed method. No significantly elevated inorganic mercury concentrations between the two groups were evident.

  7. Tetramethylpyrazine Protects Retinal Capillary Endothelial Cells (TR-iBRB2 against IL-1β-Induced Nitrative/Oxidative Stress

    Directory of Open Access Journals (Sweden)

    Xue Zhu

    2015-09-01

    Full Text Available Blood-retinal barrier (BRB breakdown is one of the primary causes of diabetic retinopathy (DR. The pro-inflammatory factor interleukin-1β (IL-1β was reported to be involved in the induction of BRB breakdown during the pathogenesis of DR. In the present study, we investigated the protective effect of tetramethylpyrazine (TMP, a major active component of the traditional herb Ligusticum chuanxiong, on IL-1β-induced cell death of the rat retinal capillary endothelial TR-iBRB2 cells. Our results showed that IL-1β-induced cell dysfunction in TR-iBRB2 cells via inducing nitrative/oxidative stress; however, such effect was attenuated with the pre-treatment of TMP. The cellular protective effect of TMP was likely to be mediated through the inhibition of inducible nitric oxide synthase (iNOS expression and leukostasis as well as suppression of reactive oxygen species (ROS generation, mitochondrial dysfunction and MAPKs activation. These findings significantly contribute to a better understanding of the protective effect of TMP in DR and form the basis of the therapeutic development of TMP in treating such disease in the future.

  8. The essential oil isolated from Artemisia capillaris prevents LPS-induced production of NO and PGE(2) by inhibiting MAPK-mediated pathways in RAW 264.7 macrophages.

    Science.gov (United States)

    Cha, Jeong-Dan; Moon, Sang-Eun; Kim, Hye-Young; Lee, Jeong-Chae; Lee, Kyung-Yeol

    2009-01-01

    Artemisia capillaris (A. capillaris) is used in traditional Korean herbal medicine for its believedanti-inflammatory activities. Previous studies have suggested that the essential oil of A. capillaris contains the active components responsible for its pharmacological effect, even though the mechanism for its action is unclear. This study examined the inhibitory effects of the essential oil of A. capillaris on the lipopolysaccharide (LPS)-induced production of nitric oxide (NO) and prostaglandin E(2) (PGE(2)). The essential oil significantly inhibited the production of NO in the LPS-stimulated RAW 264.7 macrophages, which was mediated by the down-regulation of inducible NO synthase (iNOS) expression but not by its direct cytotoxic activity. The essential oil also blocked the secretion of PGE(2) and the expression of cyclooxygenase-2 (COX-2) in the LPS-stimulated cells. Western blot analysis showed that the essential oil inhibited the phosphorylation of IkappaB-alpha, nuclear translocation of p65, and subsequent activation of NF-kappaB. In addition, the essential oil suppressed the LPS-stimulated activation of mitogen-activated protein kinases (MAPKs) as well as the AP-1 DNA-binding activity. Moreover, MAPK inhibitors significantly reduced the LPS-induced production of NO and PGE(2). Collectively, we suggest that the oil inhibits the expression and production of inflammatory mediators by blocking the MAPK-mediated pathways and inhibiting the activation of NF-kappaB and AP-1.

  9. Drug-induced trafficking of p-glycoprotein in human brain capillary endothelial cells as demonstrated by exposure to mitomycin C.

    Science.gov (United States)

    Noack, Andreas; Noack, Sandra; Hoffmann, Andrea; Maalouf, Katia; Buettner, Manuela; Couraud, Pierre-Olivier; Romero, Ignacio A; Weksler, Babette; Alms, Dana; Römermann, Kerstin; Naim, Hassan Y; Löscher, Wolfgang

    2014-01-01

    P-glycoprotein (Pgp; ABCB1/MDR1) is a major efflux transporter at the blood-brain barrier (BBB), restricting the penetration of various compounds. In other tissues, trafficking of Pgp from subcellular stores to the cell surface has been demonstrated and may constitute a rapid way of the cell to respond to toxic compounds by functional membrane insertion of the transporter. It is not known whether drug-induced Pgp trafficking also occurs in brain capillary endothelial cells that form the BBB. In this study, trafficking of Pgp was investigated in human brain capillary endothelial cells (hCMEC/D3) that were stably transfected with a doxycycline-inducible MDR1-EGFP fusion plasmid. In the presence of doxycycline, these cells exhibited a 15-fold increase in Pgp-EGFP fusion protein expression, which was associated with an increased efflux of the Pgp substrate rhodamine 123 (Rho123). The chemotherapeutic agent mitomycin C (MMC) was used to study drug-induced trafficking of Pgp. Confocal fluorescence microscopy of single hCMEC/D3-MDR1-EGFP cells revealed that Pgp redistribution from intracellular pools to the cell surface occurred within 2 h of MMC exposure. Pgp-EGFP exhibited a punctuate pattern at the cell surface compatible with concentrated regions of the fusion protein in membrane microdomains, i.e., lipid rafts, which was confirmed by Western blot analysis of biotinylated cell surface proteins in Lubrol-resistant membranes. MMC exposure also increased the functionality of Pgp as assessed in three functional assays with Pgp substrates (Rho123, eFluxx-ID Gold, calcein-AM). However, this increase occurred with some delay after the increased Pgp expression and coincided with the release of Pgp from the Lubrol-resistant membrane complexes. Disrupting rafts by depleting the membrane of cholesterol increased the functionality of Pgp. Our data present the first direct evidence of drug-induced Pgp trafficking at the human BBB and indicate that Pgp has to be released from lipid

  10. Wakefield Resonant Excitation by Intense Laser Pulse in Capillary Plasma%Wakefield Resonant Excitation by Intense Laser Pulse in Capillary Plasma

    Institute of Scientific and Technical Information of China (English)

    周素云; 袁孝; 刘明萍

    2012-01-01

    The laser-induced plasma wakefield in a capillary is investigated on the basis of a simple two-dimensional analytical model. It is shown that as an intense laser pulse reshaped by the capillary wall propagates in capillary plasma, it resonantly excites a strong wakefield if a suitable laser pulse width and capillary radius are chosen for a certain plasma density. The dependence of the laser width and capillary radius on the plasma density for resonance conditions is considered. The wakefield amplitude and longitudinal scale of bubbles in capillary plasma are much larger than those in unbounded plasma, so the capillary guided plasma wakefield is more favorable to electron acceleration.

  11. Copper stress-induced changes in leaf soluble proteome of Cu-sensitive and tolerant Agrostis capillaris L. populations.

    Science.gov (United States)

    Hego, Elena; Vilain, Sébastien; Barré, Aurélien; Claverol, Stéphane; Dupuy, Jean-William; Lalanne, Céline; Bonneu, Marc; Plomion, Christophe; Mench, Michel

    2016-05-01

    Changes in leaf soluble proteome were explored in 3-month-old plants of metallicolous (M) and nonmetallicolous (NM) Agrostis capillaris L. populations exposed to increasing Cu concentrations (1-50 μM) to investigate molecular mechanisms underlying plant responses to Cu excess and tolerance of M plants. Plants were cultivated on perlite (CuSO4 spiked-nutrient solution). Soluble proteins, extracted by the trichloroacetic acid/acetone procedure, were separated with 2-DE (linear 4-7 pH gradient). Analysis of CCB-stained gels (PDQuest) reproducibly detected 214 spots, and 64 proteins differentially expressed were identified using LC-MS/MS. In both populations, Cu excess impacted both light-dependent (OEE, cytochrome b6-f complex, and chlorophyll a-b binding protein), and -independent (RuBisCO) photosynthesis reactions, more intensively in NM leaves (ferredoxin-NADP reductase and metalloprotease FTSH2). In both populations, upregulation of isocitrate dehydrogenase and cysteine/methionine synthases respectively suggested increased isocitrate oxidation and enhanced need for S-containing amino-acids, likely for chelation and detoxification. In NM leaves, an increasing need for energetic compounds was indicated by the stimulation of ATPases, glycolysis, pentose phosphate pathway, and Calvin cycle enzymes; impacts on protein metabolism and oxidative stress increase were respectively suggested by the rise of chaperones and redox enzymes. Overexpression of a HSP70 may be pivotal for M Cu tolerance by protecting protein metabolism. All MS data have been deposited in the ProteomeXchange with the dataset identifier PXD001930 (http//proteomecentral.proteomexchange.org/dataset/PXD001930). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Capillary electrophoresis systems and methods

    Science.gov (United States)

    Dorairaj, Rathissh; Keynton, Robert S.; Roussel, Thomas J.; Crain, Mark M.; Jackson, Douglas J.; Walsh, Kevin M.; Naber, John F.; Baldwin, Richard P.; Franco, Danielle B.

    2011-08-02

    An embodiment of the invention is directed to a capillary electrophoresis apparatus comprising a plurality of separation micro-channels. A sample loading channel communicates with each of the plurality of separation channels. A driver circuit comprising a plurality of electrodes is configured to induce an electric field across each of the plurality of separation channels sufficient to cause analytes in the samples to migrate along each of the channels. The system further comprises a plurality of detectors configured to detect the analytes.

  13. Determination of penicillamine in pharmaceuticals and human plasma by capillary electrophoresis with in-column fiber optics light-emitting diode induced fluorescence detection.

    Science.gov (United States)

    Yang, Xiupei; Yuan, Hongyan; Wang, Chunling; Su, Xiaodong; Hu, Li; Xiao, Dan

    2007-10-18

    In this paper, a capillary electrophoresis (CE) system with in-column fiber optics light-emitting diode (LED) induced fluorescence detection was developed for the determination of penicillamine (PA). The influence of buffer concentration, buffer pH, applied voltage and injection time was systematically investigated. Optimum separation conditions were obtained with 10 mM borate buffer at pH 9.1, applied voltage 20 kV and 8 s hydrodynamic injection at 30 mbar. The detection system displayed linear dynamic range from 3.2 x 10(-7) to 4.8 x 10(-5) mol L(-1) with a correlation coefficient of 0.9991 and good repeatability (R.S.D.=2.46%). The method was applied to the determination of PA in commercial tablets and human plasma, which the recoveries of standard PA added to tablets and human plasma sample were found to be in the range of 96.26-102.68 and 91.10-99.35%, respectively. The proposed method is cheap, rapid, easy, and accurate, and can be successfully applied to the formulation analysis and bioanalysis.

  14. Quantification of γ-aminobutyric acid in the heads of houseflies (Musca domestica) and diamondback moths (Plutella xylostella (L.)), using capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Shi, Xueyan; Liang, Pei; Song, Dunlun; Yang, Wenling; Gao, Xiwu

    2012-02-01

    A novel method was developed for quantifying the levels of γ-aminobutyric acid (GABA) in the heads of houseflies (Musca domestica) and diamondback moths (Plutella xylostella (L.)), using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF). The GABA in sample was derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-LIF analysis. In total, 32 mmol/L borate buffer, at pH 9.2 and containing 5.3 mmol/L β-cyclodextrin (β-CD) and 10.4 mmol/L sodium dodecyl sulfate (SDS), was determined to be the optimum CE background electrolyte (BGE) for GABA analysis. The detection limit of GABA was 0.016 μmol/L. The relative standard deviations (RSDs) of the migration time and peak area of GABA were 1.78 and 4.93%, respectively. The average recoveries of 0.97, 3.88, and 5.83 μmol/L of GABA, each added to the head sample of housefly, ranged from 88.9 to 110.5%. This method is simple and applicable to GABA assays of the heads of insects. With this newly developed CE-LIF method, the amounts of GABA in the heads of houseflies (M. domestica) and diamondback moths (P. xylostella (L.)) were measured. The results are relevant to the understandings of some insecticides and insecticide-resistance mechanisms in pests.

  15. Detection of adenosine triphosphate in HeLa cell using capillary electrophoresis-laser induced fluorescence detection based on aptamer and graphene oxide.

    Science.gov (United States)

    Fang, Bi-Yun; Yao, Ming-Hao; Wang, Chun-Yuan; Wang, Chao-Yang; Zhao, Yuan-Di; Chen, Fang

    2016-04-01

    A method for ATP quantification based on dye-labeled aptamer/graphene oxide (aptamer/GO) using capillary electrophoresis-laser induced fluorescence (CE-LIF) detecting technique has been established. In this method, the carboxyfluorescein (FAM)-labelled ATP aptamers were adsorbed onto the surface of GO, leading to the fluorescence quenching of FAM; after the incubation with a limited amount of ATP, stronger affinity between ATP aptamer and ATP resulted in the desorption of aptamers and the fluorescence restoration of FAM. Then, aptamer-ATP complex and excess of aptamer/GO and GO were separated and quantified by CE-LIF detection. It was shown that a linear relation was existing in the CE-LIF peak intensity of aptamer-ATP and ATP concentration in range of 10-700 μM, the regression equation was F=1.50+0.0470C(ATP) (R(2)=0.990), and the limit of detection was 1.28 μM (3S/N, n=5), which was one order magnitude lower than that of detection in solution by fluorescence method. The approach with excellent specificity and reproducibility has been successfully applied to detecting concentration of ATP in HeLa cell.

  16. Analysis of Gums by Capillary Electrophoresis with Laser Induced Fluorescence%毛细管电泳分离和激光检测分析多糖胶

    Institute of Scientific and Technical Information of China (English)

    彭加瑜; SANDRA Pat

    2004-01-01

    将多糖胶的混合物与荧光剂9-氨基芘-1,4,6-三磺酸(APTS)派生后再进行微量离心过滤分离.所得到的高分子部分采用毛细管电泳(CE)分离和激光诱导荧光(LIF)检测技术进行分析.缓冲溶液pH的调节和聚丙烯酰胺(PAA)涂层毛细管的使用有效地改善了多糖胶的分离效率和峰形.在优化条件下,iota、kappa角叉菜胶、藻胶、xanthan、carboxymethyl cellulose (CMC)等5种组分的混合物和阿拉伯树胶、刺梧桐树胶、CMC等3种组分的混合物分别在pH 3.2和7.8的缓冲溶液下得到了完整组分的分离.这被认为是一种分析多糖胶的既简单快速又有效的方法.%Gums were derivatised with the fluorescence reagent, 9-aminopyrene-1,4,6-trisulfonic acid followed by microcentrifuge filtration. The resulting high mass fractions were analysed by capillary electrophoresis (CE) on a polyacrylamide coated capillary with laser induced fluorescence (LIF) detection. A wide pH range of electrolytes was used to study the influences on the electrophoretic mobilities and on the peak shapes of the gums. In this way, the separation of a mixture of five commercial gums, namely iota carrageenan, kappa carrageenan, alginic acid, xanthan and carboxymethyl cellulose (CMC), could be achieved at pH 3.2 with a 25 mmol/L trisodium citrate buffer. It is also shown that a mixture of Arabic gum, Karaya gum and CMC could be separated at pH 7.8 in a similar buffer.

  17. Intramedullary capillary haemangioma.

    LENUS (Irish Health Repository)

    Kelleher, T

    2012-02-03

    Intramedullary capillary haemangioma is extremely rare and only four cases have been previously reported. We describe a further case, outlining the clinical, radiological, surgical and pathological features.

  18. Protective Effects of N-Acetyl Cysteine against Diesel Exhaust Particles-Induced Intracellular ROS Generates Pro-Inflammatory Cytokines to Mediate the Vascular Permeability of Capillary-Like Endothelial Tubes.

    Directory of Open Access Journals (Sweden)

    Chia-Yi Tseng

    Full Text Available Exposure to diesel exhaust particles (DEP is associated with pulmonary and cardiovascular diseases. Previous studies using in vitro endothelial tubes as a simplified model of capillaries have found that DEP-induced ROS increase vascular permeability with rearrangement or internalization of adherens junctional VE-cadherin away from the plasma membrane. This allows DEPs to penetrate into the cell and capillary lumen. In addition, pro-inflammatory cytokines are up-regulated and mediate vascular permeability in response to DEP. However, the mechanisms through which these DEP-induced pro-inflammatory cytokines increase vascular permeability remain unknown. Hence, we examined the ability of DEP to induce permeability of human umbilical vein endothelial cell tube cells to investigate these mechanisms. Furthermore, supplementation with NAC reduces ROS production following exposure to DEP. HUVEC tube cells contributed to a pro-inflammatory response to DEP-induced intracellular ROS generation. Endothelial oxidative stress induced the release of TNF-α and IL-6 from tube cells, subsequently stimulating the secretion of VEGF-A independent of HO-1. Our data suggests that DEP-induced intracellular ROS and release of the pro-inflammatory cytokines TNF- α and IL-6, which would contribute to VEGF-A secretion and disrupt cell-cell borders and increase vasculature permeability. Addition of NAC suppresses DEP-induced ROS efficiently and reduces subsequent damages by increasing endogenous glutathione.

  19. Monitoring subcellular biotransformation of N-L-leucyldoxorubicin by micellar electrokinetic capillary chromatography coupled to laser-induced fluorescence detection.

    Science.gov (United States)

    Satori, Chad P; Meyer, Brandon; Arriaga, Edgar A

    2014-04-01

    Development of prodrugs is a promising alternative to address cytotoxicity and nonspecificity of common anticancer agents. N-L-leucyldoxorubicin (LeuDox) is a prodrug that is biotransformed to the anticancer drug doxorubicin (Dox) in the extracellular space; however, its biotransformation may also occur intracellularly in endocytic organelles. Such organelle-specific biotransformation is yet to be determined. In this study, magnetically enriched endocytic organelle fractions from human uterine sarcoma cells were treated with LeuDox. Micellar electrokinetic chromatography with laser-induced fluorescence detection (MEKC-LIF) was used to determine that 10% of LeuDox was biotransformed to Dox, accounting for ~43% of the biotransformation occurring in the post-nuclear fraction. This finding suggests that endocytic organelles also participate in the intracellular biotransformation of LeuDox to Dox.

  20. Pharmacological therapy can increase capillary density in post-infarction remodeled rat hearts

    NARCIS (Netherlands)

    Van Kerckhoven, R; van Veghel, R; Saxena, PR; Schoemaker, RG

    2004-01-01

    Objective: Postinfarction hypertrophied hearts have been shown to display a lower capillary density and reduced mechanical efficiency amplified by tachycardia. We investigated whether pharmacological reduction of postinfarction tachycardia would induce capillary growth by treating myocardial infarct

  1. Comparison of different sample treatments for the analysis of ochratoxin A in wine by capillary HPLC with laser-induced fluorescence detection.

    Science.gov (United States)

    Arroyo-Manzanares, Natalia; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2011-11-01

    Ochratoxin A (OTA) is a mycotoxin naturally found in various foods, including wine. As OTA is considered as a possible human carcinogen, the maximum concentration for this compound has been established at 2 μg kg(-1) in wine by the EU (Directive (CE) No 1881/2006). Typically, immunoaffinity columns have been used for its extraction. However, simpler, more efficient and less contaminant extraction systems are demanding. In this work, dispersive liquid-liquid microextraction using ionic liquid as extractant solvent (IL-DLLME) and the QuEChERS procedure, have been evaluated and compared for extraction of OTA in wine samples. Laser-induced fluorescence (LIF, He-Cd Laser excitation at 325 nm) coupled with capillary HPLC has been used for the determination of OTA, using a sodium dodecyl sulfate micellar solution in the mobile phase to increase the fluorescence intensity. Matrix-matched calibration curves were established for both methods, obtaining LODs (3× S/N) of 5.2 ng·L(-1) and 85.7 ng·L(-1) for IL-DLLME and QuEChERS, respectively. Clean extracts were obtained for white, rose and red wines with both methods, with recoveries between 88.7-94.2% for IL-DLLME and between 82.6-86.2% for QuEChERS. The precision was evaluated in terms of repeatability (n = 9) and intermediate precision (n = 15), being ≤ 8.5% for IL-DLLME and ≤ 5.4% for QuEChERS.

  2. Capillary electrophoresis with LED-induced native fluorescence detection for determination of isoquinoline alkaloids and their cytotoxicity in extracts of Chelidonium majus L.

    Science.gov (United States)

    Kulp, Maria; Bragina, Olga; Kogerman, Priit; Kaljurand, Mihkel

    2011-08-05

    In this study, we introduced a simple and sensitive method of capillary electrophoresis with ultraviolet light-emitting diode-induced native fluorescence (UV-LEDIF) detection for the determination of isoquinoline alkaloids in extracts of Chelidonium majus L. Samples were extracted with acidic methanol and the extracts were directly analysed by CE. Simultaneous determination of protopine, chelidonine, coptisine, sanguinarine, allocryptopine, chelerythrine and stylopine was performed in 20mM phosphate buffer (pH 3.1). The baseline separation of these alkaloids was finished within 20 min. As these alkaloids have native fluorescence, they were directly detected using the commercially available UV light emitting diode without troublesome fluorescent derivatisation. Satisfactory LOD values were obtained for the studied compounds considering their appearance in natural extracts. Lower limits of detection were 0.05 μg/mL for protopine, 0.06 μg/mL for stylopine and allocryptopine, 0.07 μg/mL for chelidonine, 0.22 μg/mL for sanguinarine, 1.7 μg/mL for chelerythrine and 5.5 μg/mL for coptisine. The developed method was successfully applied to determine the contents of seven alkaloids in the aerial parts of Chelidonium majus L, which varied from 0.025 to 0.763% (w/w). Also, to demonstrate the potential of the proposed CE method, an estimation of the cytotoxic properties of selected Celandine alkaloids in a natural extract was carried out. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Investigation of capillary electrophoresis-laser induced fluorescence as a tool in the characterization of sewage effluent for fluorescent acids: determination of salicylic acid.

    Science.gov (United States)

    Flaherty, Sean; Wark, Shelly; Street, Ginger; Farley, John W; Brumley, William C

    2002-07-01

    The investigation of emerging contaminant issues is a proactive effort in environmental analysis. As a part of this effort, sewage effluent is of current analytical interest because of the presence of pharmaceuticals and their metabolites and personal care products. The environmental impact of these components is still under investigation but their constant perfusion into receiving waters and their potential effect on biota is of concern. This paper examines a tool for the characterization of sewage effluent using capillary electrophoresis-laser induced fluorescence (CE-LIF) with a frequency-doubled laser operated in the ultraviolet (UV). Fluorescent acidic analytes are targeted because they present special problems for techniques such as gas chromatography-mass spectrometry (GC-MS) but are readily accessible to CE-LIF. As an example of the application of this tool, salicylic acid is determined near the 100 ng/L (7 x 10(-10) M) level in sewage effluent. Salicylic acid is a metabolite of various analgesics. Relatively stable in the environment, it is a common contaminant of municipal sewage systems. Salicylic acid was recovered from freshly collected samples of the effluent by liquid-liquid extraction. Confirmation of identity was by electron ionization GC-MS after conversion of the salicylic acid to the methyl ester by means of trimethylsilyldiazomethane. CE-LIF in the UV has revealed more than 50 individual peaks in the extract and a background response that suggests a large and indeterminate number of additional compounds are present. These data together with complementary techniques provide information on the complexity and components in these effluent streams.

  4. High temporal resolution for in vivo monitoring of neurotransmitters in awake epileptic rats using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detection.

    Science.gov (United States)

    Parrot, Sandrine; Sauvinet, Valérie; Riban, Véronique; Depaulis, Antoine; Renaud, Bernard; Denoroy, Luc

    2004-12-30

    A method for high temporal resolution monitoring of five neurotransmitters, dopamine (DA), noradrenaline (NA), gamma-aminobutyric acid (GABA), glutamate (Glu), l-aspartate (L-Asp), in freely-moving rats using microdialysis and capillary electrophoresis with laser-induced fluorescence detection (CE-LIFD) was developed. An on-line device, including microdialysis and derivatization with naphthalene-2,3-dicarboxaldehyde, mixes the dialysate with derivatization reagents directly in the collection tube, i.e. with no reactor. Thereafter, collected derivatized samples are analyzed off-line with an automated CE system coupled to a LIFD using a 442 nm excitation. The sampling time was limited by the minimal volume required for the analysis by the automated CE system used: neurotransmitters could be determined in 667 nl dialysates (940 nl after derivatization), i.e. in samples collected every 20 s with a flow rate of 2 microl/min. The detection limits at the dialysis probe were 3 x 10(-9), 1 x 10(-9), 1.9 x 10(-8), 4.2 x 10(-7), 2.1 x 10(-7) mol/l for DA, NA, GABA, Glu and L-Asp, respectively. The protocol was validated using in vitro/in vivo tests and the performances--repeatability, linearity, characteristics of the probes--were determined. Finally, the high temporal resolution allowed the simultaneous monitoring of these neurotransmitters in rats with genetic absence epilepsy and revealed, for the first time, increases in GABA concentrations concomitantly with the seizures, detected when our new microdialysis method was combined to electroencephalographic recordings.

  5. Capillary stretching of elastic fibers

    Science.gov (United States)

    Protiere, Suzie; Stone, Howard A.; Duprat, Camille

    2014-11-01

    Fibrous media consisting of constrained flexible fibers can be found in many engineered systems (membranes in filters, woven textile, matted paper). When such materials interact with a liquid, the presence of liquid/air interfaces induces capillary forces that deform the fibers. To model this interaction we study the behaviour of a finite volume of liquid deposited on two parallel flexible fibers clamped at both ends. A tension along the fibers is imposed and may be varied. We show that the system undergoes various morphological changes as the interfiber distance, the elasticity and the tension of the fibers are varied. For a certain range of parameters, the liquid spreads along the fibers and pulls them together, leading to the ``zipping'' of the fibers. This capillary adhesion can then be enhanced or reduced by changing the tension within the fibers. We will show that balancing stretching and capillary forces allows the prediction of this transition as well as the conditions for which detachment of the fibers occurs. These results may be used to prevent the clogging of fibrous membranes or to optimize the capture of liquids.

  6. Bundled capillary electrophoresis using microstructured fibres.

    Science.gov (United States)

    Rogers, Benjamin; Gibson, Graham T T; Oleschuk, Richard D

    2011-01-01

    Joule heating, arising from the electric current passing through the capillary, causes many undesired effects in CE that ultimately result in band broadening. The use of narrow-bore capillaries helps to solve this problem as smaller cross-sectional area results in decreased Joule heating and the rate of heat dissipation is increased by the larger surface-to-volume ratio. Issues arising from such small capillaries, such as poor detection sensitivity, low loading capacity and high flow-induced backpressure (complicating capillary loading) can be avoided by using a bundle of small capillaries operating simultaneously that share buffer reservoirs. Microstructured fibres, originally designed as waveguides in the telecommunication industry, are essentially a bundle of parallel ∼5 μm id channels that extend the length of a fibre having otherwise similar dimensions to conventional CE capillaries. This work presents the use of microstructured fibres for CZE, taking advantage of their relatively high surface-to-volume ratio and the small individual size of each channel to effect highly efficient separations, particularly for dye-labelled peptides.

  7. Sensitive and simultaneous analysis of five transgenic maizes using multiplex polymerase chain reaction, capillary gel electrophoresis, and laser-induced fluorescence.

    Science.gov (United States)

    García-Cañas, Virginia; González, Ramón; Cifuentes, Alejandro

    2004-07-01

    The benefits of using multiplex polymerase chain reaction (PCR) followed by capillary gel electrophoresis with laser-induced fluorescence (CGE-LIF) for the simultaneous detection of five transgenic maizes (Bt11, T25, MON810, GA21, and Bt176) are demonstrated. The method uses a hexaplex PCR protocol to amplify the five mentioned transgenic amplicons plus the zein gene used as reference, followed by a CGE-LIF method to analyze the six DNA fragments. CGE-LIF was demonstrated very useful and informative for optimizing multiplex PCR parameters such as time extension, PCR buffer concentration and primers concentration. The method developed is highly sensitive and allows the simultaneous detection in a single run of percentages of transgenic maize as low as 0.054% of Bt11, 0.057% of T25, 0.036% of MON810, 0.064% of GA21, and 0.018% of Bt176 in flour obtaining signals still far from the detection limit (namely, the signal/noise ratios for the corresponding DNA peaks were 41, 124, 98, 250, 252, and 473, respectively). These percentages are well below the minimum threshold marked by the European Regulation for transgenic food labeling (i.e., 0.5-0.9%). A study on the reproducibility of the multiplex PCR-CGE-LIF procedure was also performed. Thus, values of RSD lower than 0.67 and 6.80% were obtained for migration times and corrected peak areas, respectively, for the same sample and three different days (n = 12). On the other hand, the reproducibility of the whole procedure, including four different multiplex PCR amplifications, was determined to be better than 0.66 and 23.3% for migration times and corrected peak areas, respectively. Agarose gel electrophoresis (AGE) and CGE-LIF were compared in terms of resolution and sensitivity for detecting PCR products, demonstrating that CGE-LIF can solve false positives induced by artifacts from the multiplex PCR reaction that could not be addressed by AGE. Moreover, CGE-LIF provides better resolution and sensitivity. To our knowledge

  8. Capillary Bridges between Soft Substrates

    Science.gov (United States)

    Wexler, Jason S.; Heard, Tiara M.; Stone, Howard A.

    2014-02-01

    A wetting droplet trapped in the thin gap between two elastic bodies will deflect the bodies towards one another. The deformation increases the total capillary adhesion force by increasing the contact radius and narrowing the gap height. For flat droplets, with a large ratio of radius to gap height, the Laplace pressure causes surface deformations that are orders of magnitude larger than those induced by a sessile droplet of the same radius. We present experiments, scalings, and closed-form solutions that describe the deformation. Using variational techniques, we also show that the problem exhibits a bifurcation, where the gap spontaneously closes due to an incremental increase in drop volume.

  9. Gas-Filled Capillary Model

    Science.gov (United States)

    Steinhauer, L. C.; Kimura, W. D.

    2006-11-01

    We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration — Laser Wakefield (STELLA-LW) experiment.

  10. Derivatization in Capillary Electrophoresis.

    Science.gov (United States)

    Marina, M Luisa; Castro-Puyana, María

    2016-01-01

    Capillary electrophoresis is a well-established separation technique in analytical research laboratories worldwide. Its interesting advantages make CE an efficient and potent alternative to other chromatographic techniques. However, it is also recognized that its main drawback is the relatively poor sensitivity when using optical detection. One way to overcome this limitation is to perform a derivatization reaction which is intended to provide the analyte more suitable analytical characteristics enabling a high sensitive detection. Based on the analytical step where the CE derivatization takes place, it can be classified as precapillary (before separation), in-capillary (during separation), or postcapillary (after separation). This chapter describes the application of four different derivatization protocols (in-capillary and precapillary modes) to carry out the achiral and chiral analysis of different compounds in food and biological samples with three different detection modes (UV, LIF, and MS).

  11. How Capillary Rafts Sink

    CERN Document Server

    Protiere, S; Aristoff, J; Stone, H

    2010-01-01

    We present a fluid dynamics video showing how capillary rafts sink. Small objects trapped at an interface are very common in Nature (insects walking on water, ant rafts, bubbles or pollen at the water-air interface, membranes...) and are found in many multiphase industrial processes. Thanks to Archimedes principle we can easily predict whether an object sinks or floats. But what happens when several small particles are placed at an interface between two fluids. In this case surface tension also plays an important role. These particles self-assemble by capillarity and thus form what we call a "capillary raft". We show how such capillary rafts sink for varying sizes of particles and define how this parameter affects the sinking process.

  12. Simultaneous detection of genetically modified organisms by multiplex ligation-dependent genome amplification and capillary gel electrophoresis with laser-induced fluorescence.

    Science.gov (United States)

    García-Cañas, Virginia; Mondello, Monica; Cifuentes, Alejandro

    2010-07-01

    In this work, an innovative method useful to simultaneously analyze multiple genetically modified organisms is described. The developed method consists in the combination of multiplex ligation-dependent genome dependent amplification (MLGA) with CGE and LIF detection using bare-fused silica capillaries. The MLGA process is based on oligonucleotide constructs, formed by a universal sequence (vector) and long specific oligonucleotides (selectors) that facilitate the circularization of specific DNA target regions. Subsequently, the circularized target sequences are simultaneously amplified with the same couple of primers and analyzed by CGE-LIF using a bare-fused silica capillary and a run electrolyte containing 2-hydroxyethyl cellulose acting as both sieving matrix and dynamic capillary coating. CGE-LIF is shown to be very useful and informative for optimizing MLGA parameters such as annealing temperature, number of ligation cycles, and selector probes concentration. We demonstrate the specificity of the method in detecting the presence of transgenic DNA in certified reference and raw commercial samples. The method developed is sensitive and allows the simultaneous detection in a single run of percentages of transgenic maize as low as 1% of GA21, 1% of MON863, and 1% of MON810 in maize samples with signal-to-noise ratios for the corresponding DNA peaks of 15, 12, and 26, respectively. These results demonstrate, to our knowledge for the first time, the great possibilities of MLGA techniques for genetically modified organisms analysis.

  13. Microchip capillary electrophoresis with laser-induced fluorescence combined with one-step duplex reverse-transcription polymerase chain reaction for the rapid detection of Enterovirus 71 and Coxsackievirus A16 in throat swab specimens.

    Science.gov (United States)

    Jia, Ruan; Chengjun, Sun; Heng, Chen; Chen, Zhou; Yuanqian, Li; Yongxin, Li

    2015-07-01

    Enterovirus 71 and Coxsackievirus A16 are the main pathogens causing hand-foot-mouth disease. In this paper, microchip capillary electrophoresis with laser-induced fluorescence combined with one-step duplex reverse transcript-polymerase chain reaction has been developed for the detection of Enterovirus 71 and Coxsackievirus A16 in throat swab specimens. The specific reverse transcription-polymerase chain reaction amplicons labeled with SYBR Orange were separated by microchip capillary electrophoresis and detected by laser induced fluorescence detector within 7 min. The intraday and interday relative standard deviation of migration time for DNA Marker was in the range of 1.36-2.94 and 2.78-3.96%, respectively. The detection limits were as low as 2.06 × 10(3) copies/mL for Enterovirus 71 and 5 × 10(3) copies/mL for Coxsackievirus A16. No cross-reactivity was observed with rotavirus, astrovirus, norovirus, and adenovirus, which showed good specificity of the method. This assay was validated using 100 throat swab specimens that were detected by real-time reverse-transcript polymerase chain reaction in parallel and the two methods produced the same results. This study provided a rapid, sensitive and specific method for the detection of Enterovirus 71 and Coxsackievirus A16, which make a contribution to significant time and cost saving for the identification and treatment of patients.

  14. Separation of intact proteins on γ-ray-induced polymethacrylate monolithic columns: A highly permeable stationary phase with high peak capacity for capillary high-performance liquid chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Simone, Patrizia; Pierri, Giuseppe; Foglia, Patrizia; Gasparrini, Francesca; Mazzoccanti, Giulia; Capriotti, Anna Laura; Ursini, Ornella; Ciogli, Alessia; Laganà, Aldo

    2016-01-01

    Polymethacrylate-based monolithic capillary columns, prepared by γ-radiation-induced polymerization, were used to optimize the experimental conditions (nature of the organic modifiers, the content of trifluoroacetic acid and the column temperature) in the separation of nine standard proteins with different hydrophobicities and a wide range of molecular weights. Because of the excellent permeability of the monolithic columns, an ion-pair reversed-phase capillary liquid chromatography with high-resolution mass spectrometry method has been developed by coupling the column directly to the mass spectrometer without a flow-split and using a standard electrospray interface. Additionally, the high working flow and concomitant high efficiency of these columns allowed us to employ a longer column (up to 50 cm) and achieve a peak capacity value superior to 1000. This work is motivated by the need to develop new materials for high-resolution chromatographic separation that combine chemical stability at elevated temperatures (up to 75°C) and a broad pH range, with a high peak capacity value. The advantage of the γ-ray-induced monolithic column lies in the batch-to-batch reproducibility and long-term high-temperature stability. Their proven high loading capacity, recovery, good selectivity and high permeability, moreover, compared well with that of a commercially available poly(styrene-divinylbenzene) monolithic column, which confirms that such monolithic supports might facilitate analysis in proteomics.

  15. Capillary permeability in adipose tissue

    DEFF Research Database (Denmark)

    Paaske, W P; Nielsen, S L

    1976-01-01

    of about 7 ml/100 g-min. This corresponds to a capillary diffusion capacity of 2.0 ml/100 g-min which is half the value reported for vasodilated skeletal muscle having approximately twice as great capillary surface area. Thus, adipose tissue has about the same capillary permeability during slight metabolic...

  16. Mach-like capillary-gravity wakes.

    Science.gov (United States)

    Moisy, Frédéric; Rabaud, Marc

    2014-08-01

    We determine experimentally the angle α of maximum wave amplitude in the far-field wake behind a vertical surface-piercing cylinder translated at constant velocity U for Bond numbers Bo(D)=D/λ(c) ranging between 0.1 and 4.2, where D is the cylinder diameter and λ(c) the capillary length. In all cases the wake angle is found to follow a Mach-like law at large velocity, α∼U(-1), but with different prefactors depending on the value of Bo(D). For small Bo(D) (large capillary effects), the wake angle approximately follows the law α≃c(g,min)/U, where c(g,min) is the minimum group velocity of capillary-gravity waves. For larger Bo(D) (weak capillary effects), we recover a law α∼√[gD]/U similar to that found for ship wakes at large velocity [Rabaud and Moisy, Phys. Rev. Lett. 110, 214503 (2013)]. Using the general property of dispersive waves that the characteristic wavelength of the wave packet emitted by a disturbance is of order of the disturbance size, we propose a simple model that describes the transition between these two Mach-like regimes as the Bond number is varied. We show that the new capillary law α≃c(g,min)/U originates from the presence of a capillary cusp angle (distinct from the usual gravity cusp angle), along which the energy radiated by the disturbance accumulates for Bond numbers of order of unity. This model, complemented by numerical simulations of the surface elevation induced by a moving Gaussian pressure disturbance, is in qualitative agreement with experimental measurements.

  17. Actin filament-associated protein 1 (AFAP-1) is a key mediator in inflammatory signaling-induced rapid attenuation of intrinsic P-gp function in human brain capillary endothelial cells.

    Science.gov (United States)

    Hoshi, Yutaro; Uchida, Yasuo; Tachikawa, Masanori; Ohtsuki, Sumio; Terasaki, Tetsuya

    2017-01-23

    The purpose of this study was to identify regulatory molecule(s) involved in the inflammatory signaling-induced decrease in P-glycoprotein (P-gp) efflux function at the blood-brain barrier (BBB) that may occur in brain diseases. We confirmed that in vivo P-gp efflux activity at the BBB was decreased without any change in P-gp protein expression level in a mouse model of acute inflammation induced by 3 mg/kg lipopolysaccharide. In a human BBB model cell line (human brain capillary endothelial cells; hCMEC/D3), 1-h treatment with 10 ng/mL tumor necrosis factor-α (TNF-α; an inflammatory mediator) rapidly reduced P-gp efflux activity, but had no effect on P-gp protein expression level. To clarify the non-transcriptional mechanism that causes the decrease in intrinsic efflux activity of P-gp in acute inflammation, we applied comprehensive quantitative phosphoproteomics to compare hCMEC/D3 cells treated with TNF-α and vehicle (control). Actin filament-associated protein-1 (AFAP-1), MAPK1, and transcription factor AP-1 (AP-1) were significantly phosphorylated in TNF-α-treated cells, and were selected as candidate proteins. In validation experiments, knockdown of AFAP-1 expression blocked the reduction in P-gp efflux activity by TNF-α treatment, whereas inhibition of MAPK function or knockdown of AP-1 expression did not. Quantitative targeted absolute proteomics revealed that the reduction in P-gp activity by TNF-α did not require any change in P-gp protein expression levels in the plasma membrane. Our results demonstrate that AFAP-1 is a key mediator in the inflammatory signaling-induced, translocation-independent rapid attenuation of P-gp efflux activity in human brain capillary endothelial cells.

  18. Copolymers For Capillary Gel Electrophoresis

    Science.gov (United States)

    Liu, Changsheng; Li, Qingbo

    2005-08-09

    This invention relates to an electrophoresis separation medium having a gel matrix of at least one random, linear copolymer comprising a primary comonomer and at least one secondary comonomer, wherein the comonomers are randomly distributed along the copolymer chain. The primary comonomer is an acrylamide or an acrylamide derivative that provides the primary physical, chemical, and sieving properties of the gel matrix. The at least one secondary comonomer imparts an inherent physical, chemical, or sieving property to the copolymer chain. The primary and secondary comonomers are present in a ratio sufficient to induce desired properties that optimize electrophoresis performance. The invention also relates to a method of separating a mixture of biological molecules using this gel matrix, a method of preparing the novel electrophoresis separation medium, and a capillary tube filled with the electrophoresis separation medium.

  19. Flow counterbalanced capillary electrophoresis using packed capillary columns: resolution of enantiomers and isotopomers.

    Science.gov (United States)

    Henley, W Hampton; Wilburn, Richard T; Crouch, Andrew M; Jorgenson, James W

    2005-11-01

    A method with the ability to increase greatly both the resolution and efficiency of a given capillary electrophoretic system is described. This method differs from traditional capillary electrophoresis (CE) in that a counterflow is induced in the direction opposite to the electrokinetic migration of the analyte. This has the effect of extending not only the time the analytes migrate in the electric field but also the effective length and the effective applied voltage of the system. Previous work in our group with flow counterbalanced capillary electrophoresis has utilized an open tube of small inner diameter to reduce peak broadening caused by hydrodynamic flow. Narrow-diameter capillaries (5-10 microm) restricted analysis to fluorescent analytes and laser-induced fluorescence detection. The method described here uses a capillary of much larger inner diameter (75 microm) that has been packed with nonporous silica particles. The packing material reduces the amount of band broadening caused by pressure-induced flow relative to that experienced in an open tube. A larger diameter capillary allows the detection of analytes by UV absorption, not only eliminating the need to tag analytes with fluorescent tags but also allowing for the detection of a much broader range of analytes. The system was evaluated by studying the separations of several enantiomers using only beta-cyclodextrin as the chiral selector. The system was also used to resolve the two naturally occurring isotopes of bromine and to resolve phenylalanine from phenylalanine-d8. Relative to traditional CE, large improvements in resolution and separation efficiency have been achieved with this method.

  20. Practical capillary electrophoresis

    CERN Document Server

    Weinberger, Robert

    2000-01-01

    In the 1980s, capillary electrophoresis (CE) joined high-performance liquid chromatography (HPLC) as the most powerful separation technique available to analytical chemists and biochemists. Published research using CE grew from 48 papers in the year of commercial introduction (1988) to 1200 in 1997. While only a dozen major pharmaceutical and biotech companies have reduced CE to routine practice, the applications market is showing real or potential growth in key areas, particularly in the DNA marketplace for genomic mapping and forensic identification. For drug development involving small molecules (including chiral separations), one CE instrument can replace 10 liquid chromatographs in terms of speed of analysis. CE also uses aqueous rather than organic solvents and is thus environmentally friendlier than HPLC. The second edition of Practical Capillary Electrophoresis has been extensively reorganized and rewritten to reflect modern usage in the field, with an emphasis on commercially available apparatus and ...

  1. due to Capillary Forces

    Directory of Open Access Journals (Sweden)

    Hassen M. Ouakad

    2009-01-01

    Full Text Available We present modeling and analysis for the static behavior and collapse instabilities of doubly-clamped and cantilever microbeams subjected to capillary forces. These forces can be as a result of a volume of liquid trapped underneath the microbeam during the rinsing and drying process in fabrication. The model considers the microbeam as a continuous medium, the capillary force as a nonlinear function of displacement, and accounts for the mid-plane stretching and geometric nonlinearities. The capillary force is assumed to be distributed over a specific length underneath the microbeam. The Galerkin procedure is used to derive a reduced-order model consisting of a set of nonlinear algebraic and differential equations that describe the microbeams static and dynamic behaviors. We study the collapse instability, which brings the microbeam from its unstuck configuration to touch the substrate and gets stuck in the so-called pinned configuration. We calculate the pull-in length that distinguishes the free from the pinned configurations as a function of the beam thickness and gap width for both microbeams. Comparisons are made with analytical results reported in the literature based on the Ritz method for linear and nonlinear beam models. The instability problem, which brings the microbeam from a pinned to adhered configuration is also investigated. For this case, we use a shooting technique to solve the boundary-value problem governing the deflection of the microbeams. The critical microbeam length for this second instability is also calculated.

  2. In-capillary derivatization and capillary electrophoresis separation of amino acid neurotransmitters from brain microdialysis samples.

    Science.gov (United States)

    Denoroy, Luc; Parrot, Sandrine; Renaud, Louis; Renaud, Bernard; Zimmer, Luc

    2008-09-26

    A new in-capillary derivatization method with naphtalene-2,3-dicarboxyaldehyde (NDA)/CN(-) has been developed for capillary electrophoresis with laser-induced fluorescence detection of brain microdialysate amino acids. Samples are sandwiched between two plugs of reagent mixture at the capillary inlet and subsequently separated. Highest derivatization yields are obtained by using a reagent to sample plug length ratio equal to 4, performing a first electrophoretic mixing followed by a zero potential amplification step before applying the separation voltage and using a NaCN to NDA concentration ratio equal to 1. This new single-step methodology allows the analysis of amino acid neurotransmitters in rat brain microdialysis samples.

  3. Tapered capillary optics

    Science.gov (United States)

    Hirsch, Gregory

    1998-01-01

    A metal or glass wire is etched with great precision into a very narrowly tapering cone which has the shape of the desired final capillary-optics bore. By controlling the rate of removal of the wire from an etchant bath, a carefully controlled taper is produced. A sensor measures the diameter of the wire as it leaves the surface of the etchant. This signal is used for feedback control of the withdrawal speed. The etched wire undergoes a treatment to produce an extremely low surface-roughness. The etched and smoothed wire is coated with the material of choice for optimizing the reflectivity of the radiation being focused. This could be a vacuum evaporation, sputtering, CVD or aqueous chemical process. The coated wire is either electroplated, built up with electroless plating, or encapsulated in a polymer cylinder such as epoxy to increase the diameter of the wire for easier handling and greater robustness. During this process, the wire is vertically oriented and tensioned to assure that the wire is absolutely straight. The coated and electroformed wire is bonded to a flat, rigid substrate and is then periodically segmented by cutting or etching a series of narrow slits or grooves into the wire. The wire is vertically oriented and tensioned during the bonding process to assure that it is straight. The original wire material is then chemically etched away through the slits or otherwise withdrawn to leave the hollow internal bore of the final tapered-capillary optical element.

  4. 20 Years of Fatty Acid Analysis by Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Marcone Augusto Leal de Oliveira

    2014-09-01

    Full Text Available A review taking into account the literature reports covering 20 years of fatty acid analysis by capillary electrophoresis is presented. This paper describes the evolution of fatty acid analysis using different CE modes such as capillary zone electrophoresis, non-aqueous capillary electrophoresis, micellar electrokinetic capillary chromatography and microemulsion electrokinetic chromatography employing different detection systems, such as ultraviolet-visible, capacitively coupled contactless conductivity, laser-induced fluorescence and mass spectrometry. In summary, the present review signals that CE seems to be an interesting analytical separation technique that is very useful for screening analysis or quantification of the usual fatty acids present in different matrices, offering short analysis times and a simple sample preparation step as inherent advantages in comparison with the classical methodology, making it a separation technique that is very attractive for quality control in industry and government agencies.

  5. Ketoprofen analysis in serum by capillary electrophoresis.

    Science.gov (United States)

    Friedberg, M; Shihabi, Z K

    1997-07-18

    A method for the quantification of ketoprofen, a new non-prescription non-steroidal anti-inflammatory drug, in serum, by capillary zone electrophoresis for therapeutic monitoring and emergency toxicology is described. Serum is deproteinized with acetonitrile in the presence of an internal standard, to remove serum proteins and to induce sample stacking. The migration time was about 10 min. The assay was linear between 1-10 mg/l without any interferences. The method compared well to an HPLC assay. The HPLC afforded a better detection limit, but the CE was less expensive to operate. This method demonstrates that capillary electrophoresis is a simple and effective method for determination of ketoprofen as well as other drugs in human serum at levels close to 1 mg/l.

  6. Capillaries modified by noncovalent anionic polymer adsorption for capillary zone electrophoresis, micellar electrokinetic capillary chromatography and capillary electrophoresis mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L; Hansen, S H; Gammelgaard, Bente

    2001-01-01

    A simple coating procedure for generation of a high and pH-independent electroosmotic flow in capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) is described. The bilayer coating was formed by noncovalent adsorption of the ionic polymers Polybrene...

  7. Biomedical applications of capillary electrophoresis

    Science.gov (United States)

    Kartsova, L. A.; Bessonova, E. A.

    2015-08-01

    The review deals with modern analytical approaches used in capillary electrophoresis for solving medical and biological problems: search for biomarkers of various diseases and rapid diagnosis based on characteristic profiles of biologically active compounds by capillary electrophoresis with mass spectrometric detection; monitoring of the residual drugs in biological fluids for evaluating the efficiency of drug therapy; testing of the enantiomeric purity of pharmaceutical products; the use of novel materials as components of stationary and pseudo-stationary phases in capillary electrophoresis and capillary electrochromatography to increase the selectivity of separation of components of complex matrices; and identification of various on-line preconcentration techniques to reduce the detection limits of biologically active analytes. A topical trend in capillary electrophoresis required in clinical practice, viz., the design of microfluidic systems, is discussed. The bibliography includes 173 references.

  8. Physiological factors influencing capillary growth.

    Science.gov (United States)

    Egginton, S

    2011-07-01

    (1) Angiogenesis (growth of new capillaries from an existing capillary bed) may result from a mismatch in microvascular supply and metabolic demand (metabolic error signal). Krogh examined the distribution and number of capillaries to explore the correlation between O(2) delivery and O(2) consumption. Subsequently, the heterogeneity in angiogenic response within a muscle has been shown to reflect either differences in fibre type composition or mechanical load. However, local control leads to targetted angiogenesis in the vicinity of glycolytic fibre types following muscle stimulation, or oxidative fibres following endurance training, while heterogeneity of capillary spacing is maintained during ontogenetic growth. (2) Despite limited microscopy resolution and lack of specific markers, Krogh's interest in the structure of the capillary wall paved the way for understanding the mechanisms of capillary growth. Angiogenesis may be influenced by the response of perivascular or stromal cells (fibroblasts, macrophages and pericytes) to altered activity, likely acting as a source for chemical signals modulating capillary growth such as vascular endothelial growth factor. In addition, haemodynamic factors such as shear stress and muscle stretch play a significant role in adaptive remodelling of the microcirculation. (3) Most indices of capillarity are highly dependent on fibre size, resulting in possible bias because of scaling. To examine the consequences of capillary distribution, it is therefore helpful to quantify the area of tissue supplied by individual capillaries. This allows the spatial limitations inherent in most models of tissue oxygenation to be overcome generating an alternative approach to Krogh's tissue cylinder, the capillary domain, to improve descriptions of intracellular oxygen diffusion. © 2010 The Author. Acta Physiologica © 2010 Scandinavian Physiological Society.

  9. Multidimensional capillary electrophoresis.

    Science.gov (United States)

    Grochocki, Wojciech; Markuszewski, Michał J; Quirino, Joselito P

    2015-01-01

    Multidimensional separation where two or more orthogonal displacement mechanisms are combined is a promising approach to increase peak capacity in CE. The combinations allow dramatic improvement of analytical performance since the total peak capacity is given by a product of the peak capacities of all methods. The initial reports were concentrated on the construction of effective connections between capillaries for 2D analysis. Today, 2D and 3D CE systems are now able to separate real complex biological or environmental mixtures with good repeatability, improved resolution with minimal loss of sample. This review will present the developments in the field of multidimensional CE during the last 15 years. The endeavors in this specific field were on the development of interfaces, interface-free techniques including integrated separations, microdevices, and on-line sample concentration techniques to improve detection sensitivity.

  10. Capillaries for use in a multiplexed capillary electrophoresis system

    Science.gov (United States)

    Yeung, E.S.; Chang, H.T.; Fung, E.N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  11. Capillary adhesion forces between flexible fibers

    Science.gov (United States)

    Duprat, Camille; Protière, Suzie

    2016-11-01

    We consider the capillary adhesion produced by a drop placed between two elastic fibers. We measure the force exerted by the drop as we vary the inter-fiber distance, and report two types of wet adhesion: a weak capillary adhesion, where a liquid drop bridges the fibers, and a strong elastocapillary adhesion where the liquid is spread between two collapsed fibers. The weak adhesion is characterized by a force that increases linearly with the liquid length. With flexible fibers, the force exerted by the drop can induce deformation and rapid collapse, or zipping, of the fibers. This zipping results in a sudden increase of the wetted length and a force that departs from the linear evolution. As the inter-fiber distance is subsequently increased, the liquid length decreases while the fibers deformation increases, and the force actually reaches a plateau, i.e. remains constant until unzipping, or detachment of the fibers occurs. We measure the value of this plateau, i.e. the maximal adhesion force, as we vary the drop volume and the fibers elasticity. We also show that flexibility extends capillary adhesion to inter-fiber distances impossible to reach with rigid fibers, while keeping a constant pull-out force characteristic of the elastocapillary coupling.

  12. Capillary flow solder wettability test

    Energy Technology Data Exchange (ETDEWEB)

    Vianco, P.T.; Rejent, J.A.

    1996-01-01

    A test procedure was developed to assess the capillary flow wettability of solders inside of a confined geometry. The test geometry was comprised of two parallel plates with a controlled gap of constant thickness (0.008 cm, 0.018 cm, 0.025 cm, and 0.038 cm). Capillary flow was assessed by: (1) the meniscus or capillary rise of the solder within the gap, (2) the extent of void formation in the gap, and (3) the time-dependence of the risen solder film. Tests were performed with the lead-free solders.

  13. Stability of capillary gels for automated sequencing of DNA.

    Science.gov (United States)

    Swerdlow, H; Dew-Jager, K E; Brady, K; Grey, R; Dovichi, N J; Gesteland, R

    1992-08-01

    Recent interest in capillary gel electrophoresis has been fueled by the Human Genome Project and other large-scale sequencing projects. Advances in gel polymerization techniques and detector design have enabled sequencing of DNA directly in capillaries. Efforts to exploit this technology have been hampered by problems with the reproducibility and stability of gels. Gel instability manifests itself during electrophoresis as a decrease in the current passing through the capillary under a constant voltage. Upon subsequent microscopic examination, bubbles are often visible at or near the injection (cathodic) end of the capillary gel. Gels have been prepared with the polyacrylamide matrix covalently attached to the silica walls of the capillary. These gels, although more stable, still suffer from problems with bubbles. The use of actual DNA sequencing samples also adversely affects gel stability. We examined the mechanisms underlying these disruptive processes by employing polyacrylamide gel-filled capillaries in which the gel was not attached to the capillary wall. Three sources of gel instability were identified. Bubbles occurring in the absence of sample introduction were attributed to electroosmotic force; replacing the denaturant urea with formamide was shown to reduce the frequency of these bubbles. The slow, steady decline in current through capillary sequencing gels interferes with the ability to detect other gel problems. This phenomenon was shown to be a result of ionic depletion at the gel-liquid interface. The decline was ameliorated by adding denaturant and acrylamide monomers to the buffer reservoirs. Sample-induced problems were shown to be due to the presence of template DNA; elimination of the template allowed sample loading to occur without complications.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Analysis of Capillary Rise in Asymmetric Branch-Like Capillary

    Science.gov (United States)

    Li, Caoxiong; Shen, Yinghao; Ge, Hongkui; Yang, Zhihui; Su, Shuai; Ren, Kai; Huang, Heyu

    2016-05-01

    Transport in porous media is common in nature, attracting many attentions for a long time. Tree-like network model is often used as a simplification for porous space, expressing the complexity of pore spaces instead of capillary bundle. To investigate spontaneous imbibition characteristics in this network, a dynamic asymmetric branch-like capillary model is used to represent basic network structure, using fractal method to represent tortuosity. This work investigates the influence of parameters on imbibition process in the branch-like capillary model. An analytical equation for the imbibition mass versus time is derived. Parameters from capillary structures to liquid properties are taken into account and analyzed based on the numerical solution of the equation. It is found that the imbibition process in asymmetric branch-like capillary model can be recognized by four sections and brunching tubes are positive for imbibition process. Concomitantly, meniscus arrest event is simulated and discussed. Moreover, the influence of parameters on imbibition process is discussed. These parameters can be classified as static and dynamic. Static parameters mainly change the capillary force, which are related to the ultimate imbibition mass or imbibition ability, while dynamic parameters mainly have influence on resistance of flowing fluid, which are related to the imbibition speed in the imbibition process.

  15. Selectivity in capillary electrokinetic separations

    NARCIS (Netherlands)

    de Zeeuw, R.A; de Jong, G.J.; Ensing, K

    1999-01-01

    This review gives a survey of selectivity modes in capillary electrophoresis separations in pharmaceutical analysis and bioanalysis. Despite the high efficiencies of these separation techniques, good selectivity is required to allow quantitation or identification of a Chemistry and Toxicology, parti

  16. DNA typing by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, N.

    1997-10-08

    Capillary electrophoresis is becoming more and more important in nucleic acid analysis including DNA sequencing, typing and disease gene measurements. This work summarized the background of DNA typing. The recent development of capillary electrophoresis was also discussed. The second part of the thesis showed the principle of DNA typing based on using the allelic ladder as the absolute standard ladder in capillary electrophoresis system. Future work will be focused on demonstrating DNA typing on multiplex loci and examples of disease diagnosis in the on-line format of PCR-CE. Also capillary array electrophoresis system should allow high throughput, fast speed DNA typing. Only the introduction and conclusions for this report are available here. A reprint was removed for separate processing.

  17. In vivo simultaneous monitoring of gamma-aminobutyric acid, glutamate, and L-aspartate using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detection: Analytical developments and in vitro/in vivo validations.

    Science.gov (United States)

    Sauvinet, Valérie; Parrot, Sandrine; Benturquia, Nadia; Bravo-Moratón, Eva; Renaud, Bernard; Denoroy, Luc

    2003-09-01

    gamma-Aminobutyric acid (GABA), glutamate (Glu), and L-aspartate (L-Asp) are three major amino acid neurotransmitters in the central nervous system. In this work, a method for the separation of these three neurotransmitters in brain microdialysis samples using a commercially available capillary electrophoresis (CE) system has been developed. Molecules were tagged on their primary amine function with the fluorogene agent naphthalene-2,3-dicarboxaldehyde (NDA), and, after separation by micellar electrokinetic chromatography, were detected by laser-induced fluorescence using a 442 nm helium-cadmium laser. The separation conditions for the analysis of derivatized neurotransmitters in standard solutions and microdialysates have been optimized, and this method has been validated on both pharmacological and analytical basis. The separation of GABA, Glu, and L-Asp takes less than 10 min by using a 75 mmol/L borate buffer, pH 9.2, containing 70 mmol/L SDS and 10 mmol/L hydroxypropyl-beta-cyclodextrin and + 25 kV voltage. The detection limits were 3, 15 nmol/L and, 5 nmol/L for GABA, Glu, and L-Asp, respectively. Moreover, submicroliter samples can be analyzed. This method allows a simple, rapid and accurate measurement of the three amino acid neurotransmitters for the in vivo brain monitoring using microdialysis sampling.

  18. Microdialysis monitoring of catecholamines and excitatory amino acids in the rat and mouse brain: recent developments based on capillary electrophoresis with laser-induced fluorescence detection--a mini-review.

    Science.gov (United States)

    Parrot, Sandrine; Bert, Lionel; Mouly-Badina, Laurence; Sauvinet, Valérie; Colussi-Mas, Joyce; Lambás-Señas, Laura; Robert, Frédéric; Bouilloux, Jean-Pierre; Suaud-Chagny, Marie-Françoise; Denoroy, Luc; Renaud, Bernard

    2003-10-01

    1. Although microdialysis is a widely used approach for in vivo monitoring extracellular neurotransmitter concentrations, it has been previously limited in many cases by its poor temporal resolution. It is clear that when 10-30-min sampling is performed, short-lasting changes in extracellular neurotransmitter concentrations can be overlooked. Such a low sampling rate is necessary when combining microdialysis with the conventional analytical methods like high performance liquid chromatography. 2. Since capillary electrophoresis coupled to laser-induced fluorescence detection (CE-LIFD) allows the detection of attomoles of neurotransmitters, the temporal resolution of microdialysis may be significantly improved: high sampling rates, in the range of 5 s to 1 min, have been already reported by our group and others using CE-LIFD for simultaneously analyzing catecholamines and amino acids in microdialysates. 3. The power of combining microdialyis and CE-LIFD is shown, using examples of physiological and pharmacological studies dealing with the dynamics of in vivo efflux processes and/or interactions between neurotransmitters.

  19. Gravimetric capillary method for kinematic viscosity measurements

    Science.gov (United States)

    Rosenberger, Franz; Iwan, J.; Alexander, D.; Jin, Wei-Qing

    1992-01-01

    A novel version of the capillary method for viscosity measurements of liquids is presented. Viscosity data can be deduced in a straightforward way from mass transfer data obtained by differential weighing during the gravity-induced flow of the liquid between two cylindrical chambers. Tests of this technique with water, carbon tetrachloride, and ethanol suggest that this arrangement provides an accuracy of about +/- 1 percent. The technique facilitates operation under sealed, isothermal conditions and, thus can readily be applied to reactive and/or high vapor pressure liquids.

  20. Two-dimensional capillary electrophoresis using tangentially connected capillaries.

    Science.gov (United States)

    Sahlin, Eskil

    2007-06-22

    A novel type of fused silica capillary system is described where channels with circular cross-sections are tangentially in contact with each other and connected through a small opening at the contact area. Since the channels are not crossing each other in the same plane, the capillaries can easily be filled with different solutions, i.e. different solutions will be in contact with each other at the contact point. The system has been used to perform different types of two-dimensional separations and the complete system is fully automated where a high voltage switch is used to control the location of the high voltage in the system. Using two model compounds it is demonstrated that a type of two-dimensional separation can be performed using capillary zone electrophoresis at two different pH values. It is also shown that a compound with acid/base properties can be concentrated using a dynamic pH junction mechanism when transferred from the first separation to the second separation. In addition, the system has been used to perform a comprehensive two-dimensional capillary electrophoresis separation of tryptic digest of bovine serum albumin using capillary zone electrophoresis followed by micellar electrokinetic chromatography.

  1. Investigation of X-ray lasing in a capillary discharge

    NARCIS (Netherlands)

    Ellwi, S. S.; Juschkin, L.; Ferri, S.; Kunze, H. J.; E. Louis,

    2001-01-01

    Using a new technique of an induced MHD instability in a capillary made of polyacetal we observed an intense spike (signal) of the Balmer-a line of C VI at 18.22 nm during the second half cycle of the discharge. The spike is identified as Amplified Spontaneous Emission (ASE), and enhancements are de

  2. Speciation analysis of organomercurial compounds in Fish Tissue by capillary gas chromatography coupled to microwave-induced plasma atomic emission detection

    Directory of Open Access Journals (Sweden)

    Dorfe Díaz

    Full Text Available This paper describes a novel approach for analysis of mercury speciation in fish using gas chromatography coupled with microwave-induced plasma optical emission spectrometry (GC-MIP-OES in surfatron resonant cavity. Sample treatment was based on quantitative leaching of mercury species from fish tissue with ultrasound-assisted acid-toluene extraction. The extracted mercury species analyzed with GC-MIP-OES attained detection limits of 5 and 9 pg for methylmercury (MeHg and ethylmercury (EtHg, respectively. A complete chromatogram could be completed in 1.5 min. MeHg values obtained with GC-MIP-OES were matched with organic mercury values obtained with selective reduction cold vapour- atomic absorption spectrometry (CV-AAS.

  3. Vorticity and Capillaries at the Surface of a Jet

    CERN Document Server

    Andre, Matthieu A

    2012-01-01

    Shear layer instability at the free surface of a water jet is studied. The accompanying video shows experimental data recorded using measurement methods such as Planar Laser Induced Fluorescence (PLIF) and Particle Image Velocity (PIV). These results reveal the mechanisms leading to the formation of capillary waves on the surface due to the roll-up of the shear layer. These capillary waves eventually collide to each other, injecting vorticity in the bulk of the flow. Shear layer and injected vorticity interact to form a counter rotating vortex pair that moves down to the flow.

  4. Capillary Electrophoresis in the Analysis of Polyunsaturated Fatty Acids

    Directory of Open Access Journals (Sweden)

    Gabriel Hancu

    2015-12-01

    Full Text Available The aim of this study to inventory the main electrophoretic methods for identification and quantitative determination of fatty acids from different biological matrices. Critical analysis of electrophoretic methods reported in the literature show that the determination of polyunsaturated fatty acids can be made by: capillary zone electrophoresis, micellar electrokinetic chromatography and microemulsion electrokinetic chromatography using different detection systems such as ultraviolet diode array detection, laser induced fluorescence or mass – spectrometry. Capillary electrophoresis is a fast, low-cost technique used for polyunsaturated fatty acids analysis although their determination is mostly based on gas chromatography.

  5. Computation of Capillary Interactions among Many Particles at Free Surface

    Science.gov (United States)

    Fujita, Masahiro; Koike, Osamu; Yamaguchi, Yukio

    2013-03-01

    We have developed a new computational method to efficiently estimate capillary interactions among many moving particles at a free surface. A novelty of the method is the immersed free surface (IFS) model that transforms the surface tension exerted on a three-phase contact line on a particle surface into the surface tension exerted on an artificially created virtual free surface in the particle. Using the IFS model along with a level set method and an immersed boundary method, we have reasonably simulated a capillary-force-induced self-assembly of particles that is common in coating-drying of particle suspension.

  6. Vesicle dynamics in shear and capillary flows

    Science.gov (United States)

    Noguchi, Hiroshi; Gompper, Gerhard

    2005-11-01

    The deformation of vesicles in flow is studied by a mesoscopic simulation technique, which combines multi-particle collision dynamics for the solvent with a dynamically triangulated surface model for the membrane. Shape transitions are investigated both in simple shear flows and in cylindrical capillary flows. We focus on reduced volumes, where the discocyte shape of fluid vesicles is stable, and the prolate shape is metastable. In simple shear flow at low membrane viscosity, the shear induces a transformation from discocyte to prolate with increasing shear rate, while at high membrane viscosity, the shear induces a transformation from prolate to discocyte, or tumbling motion accompanied by oscillations between these two morphologies. In capillary flow, at small flow velocities the symmetry axis of the discocyte is found not to be oriented perpendicular to the cylinder axis. With increasing flow velocity, a transition to a prolate shape occurs for fluid vesicles, while vesicles with shear-elastic membranes (like red blood cells) transform into a coaxial parachute-like shape.

  7. New type of capillary for use as ion beam collimator and air-vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Stoytschew, V., E-mail: valostoytschew@hotmail.com [Ruđer Bošković Institute, Bijenicka Cesta 54, 10000 Zagreb (Croatia); Schulte-Borchers, M. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, CH-8093 Zurich (Switzerland); Božičević Mihalića, Iva [Ruđer Bošković Institute, Bijenicka Cesta 54, 10000 Zagreb (Croatia); Perez, R.D. [FaMAF, Universidad Nacional de Córdoba, (5000) Ciudad Universitaria, Córdoba (Argentina)

    2016-08-01

    Glass capillaries offer a unique way to combine small diameter ion beam collimation with an air-vacuum interface for ambient pressure ion beam applications. Usually they have an opening diameter of a few microns, limiting the air inflow sufficiently to maintain stable conditions on the vacuum side. As the glass capillaries generally are quite thin and fragile, handling of the capillary in the experiment becomes difficult. They also introduce an X-ray background produced by the capillary wall material, which has to be shielded or subtracted from the data for Particle Induced X-ray Emission (PIXE) applications. To overcome both drawbacks, a new type of conical glass capillary has been developed. It has a higher wall thickness eliminating the low energy X-ray background produced by common capillaries and leading to a more robust lens. The results obtained in first tests show, that this new capillary is suitable for ion beam collimation and encourage further work on the capillary production process to provide thick wall capillaries with an outlet diameter in the single digit micro- or even nanometre range.

  8. Gas Flow Dynamics in Inlet Capillaries: Evidence for non Laminar Conditions

    Science.gov (United States)

    Wißdorf, Walter; Müller, David; Brachthäuser, Yessica; Langner, Markus; Derpmann, Valerie; Klopotowski, Sebastian; Polaczek, Christine; Kersten, Hendrik; Brockmann, Klaus; Benter, Thorsten

    2016-09-01

    In this work, the characteristics of gas flow in inlet capillaries are examined. Such inlet capillaries are widely used as a first flow restriction stage in commercial atmospheric pressure ionization mass spectrometers. Contrary to the common assumption, we consider the gas flow in typical glass inlet capillaries with 0.5 to 0.6 mm inner diameters and lengths about 20 cm as transitional or turbulent. The measured volume flow of the choked turbulent gas stream in such capillaries is 0.8 L·min-1 to 1.6 L·min-1 under typical operation conditions, which is in good agreement to theoretically calculated values. Likewise, the change of the volume flow in dependence of the pressure difference along the capillary agrees well with a theoretical model for turbulent conditions as well as with exemplary measurements of the static pressure inside the capillary channel. However, the results for the volume flow of heated glass and metal inlet capillaries are neither in agreement with turbulent nor with laminar models. The velocity profile of the neutral gas in a quartz capillary with an inner diameter similar to commercial inlet capillaries was experimentally determined with spatially resolved ion transfer time measurements. The determined gas velocity profiles do not contradict the turbulent character of the flow. Finally, inducing disturbances of the gas flow by placing obstacles in the capillary channel is found to not change the flow characteristics significantly. In combination the findings suggest that laminar conditions inside inlet capillaries are not a valid primary explanation for the observed high ion transparency of inlet capillaries under common operation conditions.

  9. Fluorescence detection in capillary arrays based on galvanometer step scanning.

    Science.gov (United States)

    Xue, G; Yeung, E S

    2001-10-01

    A computer-controlled galvanometer scanner is adapted for scanning a focused laser beam across a 96-capillary array for laser-induced fluorescence detection. The signal at a single photomultiplier tube is temporally sorted to distinguish among the capillaries. The limit of detection for fluoresceins is 3 x 10(-11) M (S/N = 3) for 5 mW of total laser power scanned at 4 Hz. The observed cross-talk among capillaries is 0.2%. Advantages include the efficient utilization of light due to the high duty-cycle of step scan, good detection performance due to the reduction of stray light, ruggedness due to the small mass of the galvanometer mirror, low cost due to the simplicity of components, and flexibility due to the independent paths for excitation and emission.

  10. Capillary Pressure and Contact Line Force on a Soft Solid

    CERN Document Server

    Marchand, Antonin; Snoeijer, Jacco H; Andreotti, Bruno

    2012-01-01

    The surface free energy, or surface tension, of a liquid interface gives rise to a pressure jump when the interface is curved. Here we show that a similar capillary pressure arises at the interface of soft solids. We present experimental evidence that immersion of a thin elastomeric wire into a liquid induces a substantial elastic compression due to the solid capillary pressure at the bottom. We quantitatively determine the effective surface tension from the elastic displacement field, and find a value comparable to the liquid-vapor surface tension. Most importantly, these results also reveal the way the liquid pulls on the solid close to the contact line: the capillary force is not oriented along the liquid-air interface, nor perpendicularly to the solid surface, as previously hypothesized, but towards the interior of the liquid.

  11. Capillary Rise of Magnetohydrodynamics Liquid into Deformable Porous Material

    Directory of Open Access Journals (Sweden)

    Javed I Siddique

    2016-01-01

    Full Text Available We have developed a mathematical model for capillary rise of magnetohydrodynamic fluids. The liquid starts to imbibe because of capillary suction in an undeformed and initially dry sponge-like porous material. The driving force in our model is a pressure gradient across the evolving porous material that induces a stress gradient which in turn causes deformation that is characterized by a variable solid fraction. The problem is formulated as a non–linear moving boundary problem which we solve using the method of lines approach after transforming to a fixed computational domain. The summary of our finding includes a notable reduction in capillary rise and a decrease in solid deformation due to magnetic effects.

  12. Impacts on oil recovery from capillary pressure and capillary heterogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Bognoe, Thomas

    2008-07-01

    The main conclusions drawn from this thesis are; 7 scientific papers are published on a broad variety of subjects, and describes in detail the experiments and research treated in this thesis. Scientific research has been performed, investigating the subjects of capillary pressure and capillary heterogeneities from different angles. This thesis discusses the findings in this study and aims to illustrate the benefits of the results obtained for further development of other experiments, and/or even the industrial benefits in field development. The methods for wettability alteration have developed throughout the work. From producing heterogeneous wettability alterations, the methods have improved to giving both radial and lateral uniform wettability alterations, which also remains unaltered throughout the duration of the experimental work. The alteration of wettability is dependent on initial water saturation, flow rate, aging time and crude oil composition. Capillary pressure and relative permeability curves have been measured for core plugs at different wettabilities using conventional centrifuge methods. The trends observed are mostly consistent with theory. The production mechanisms of strongly and moderately water wet chalk has been investigated. At strongly water wet conditions in fractured chalk; the flow is governed by capillary forces, showing strong impact from the fractures. At moderately water wet conditions, the impact of the fractures are absent, and a dispersed water front is observed during the displacement. The oil recovery is about the same, at the two wettabilities. Fracture crossing mechanisms at the same wettability conditions have been mapped. And the observations are consistent with those of the water floods. During strongly water wet displacement, the fracture crossing is occurring once the inlet core has reached endpoint of spontaneous imbibition. At moderately water wet conditions the fracture crossing is less abrupt, and creation of wetting

  13. On the role of capillary instabilities in the sandcastle effect

    Energy Technology Data Exchange (ETDEWEB)

    Du Binyang; Koenig, Alexander Martin; Johannsmann, Diethelm [Institute of Physical Chemistry, Clausthal University of Technology, Arnold-Sommerfeld-Str. 4, D-38678 Clausthal-Zellerfeld (Germany)], E-mail: johannsmann@pc.tu-clausthal.de

    2008-05-15

    Using acoustic resonators, we have investigated the mechanical stiffness of contacts between rough surfaces. In the first part, the underlying acoustic model is validated with experiments showing a transition from elastic to inertial loading. The second part is concerned with the increase in contact stiffness induced by transient exposure to a humid environment. A novel mode of surface deformation is proposed, which builds on a capillary instability. Under certain conditions, a slight decrease in the mean distance between the two surfaces may induce a rather strong increase in capillary attraction, while leaving the elastic forces of repulsion almost constant. The thus-created negative differential spring constant induces a collapse of the gap in-between neighboring load-bearing asperities. The initial decrease in distance may either be induced by local asperity creep or by distortions of the contacting surfaces on a larger scale, which improve the interlock of the asperities at a small cost of strain energy.

  14. Non-Aqueous Capillary Electrophoresis

    Science.gov (United States)

    Szumski, Michał; Buszewski, Bogusław

    Non-aqueous capillary electrophoresis and capillary electrochromatography are special variants of these techniques. Here, organic solvents or their mixtures with or without dissolved electrolytes are used as separation buffer or mobile phase, respectively. The most important features of non-aqueous systems are: better solubility of more hydrophobic ionic substances (many natural products) than in water, much less current and Joule heating allows for using highly concentrated buffers and/or larger capillary internal diameters, polar interactions are enhanced in organic solvents which is often highly advantageous in chiral separation systems. This chapter presents most frequently used solvents, their properties, as well as shows pH* scale which is often used in non-aqueous systems.

  15. Capillary imbibition in parallel tubes

    Science.gov (United States)

    McRae, Oliver; Ramakrishnan, T. S.; Bird, James

    2016-11-01

    In modeling porous media two distinct approaches can be employed; the sample can be examined holistically, using global variables such as porosity, or it can be treated as a network of capillaries connected in series to various intermediate reservoirs. In forced imbibition this series-based description is sufficient to characterize the flow, due to the presence of an externally maintained pressure difference. However, in spontaneous imbibition, flow is driven by an internal capillary pressure, making it unclear whether a series-based model is appropriate. In this talk, we show using numerical simulations the dynamics of spontaneous imbibition in concentrically arranged capillary tubes. This geometry allows both tubes access to a semi-infinite reservoir but with inlets in close enough proximity to allow for interference. We compare and contrast the results of our simulations with theory and previous experiments. Schlumberger-Doll Research.

  16. Electrical resistance of a capillary endothelium

    Science.gov (United States)

    1981-01-01

    The electrical resistance of consecutive segments of capillaries has been determined by a method in which the microvessels were treated as a leaky, infinite cable. A two-dimensional analytical model to describe the potential field in response to intracapillary current injection was formulated. The model allowed determination of the electrical resistance from four sets of data: the capillary radius, the capillary length constant, the length constant in the mesentery perpendicular to the capillary, and the relative potential drop across the capillary wall. Of particular importance were the mesothelial membranes covering the mesenteric capillaries with resistances several times higher than that of the capillary endothelium. 27 frog mesenteric capillaries were characterized. The average resistance of the endothelium was 1.85 omega cm2, which compares well with earlier determinations of the ionic permeability of such capillaries. However, heterogeneity with respect to resistance was observed, that of 10 arterial capillaries being 3.0 omega cm2 as compared with 0.95 omega cm2 for 17 mid- and venous capillaries. The average in situ length constant was 99 micrometers for the arterial capillaries and 57 micrometers for the mid- and venous capillaries. It is likely that the ions that carry the current must move paracellularly, through junctions that are leaky to small solutes. PMID:7241087

  17. Effects of analyte velocity modulation on the electroosmotic flow in capillary electrophoresis.

    Science.gov (United States)

    Demana, T; Guhathakurta, U; Morris, M D

    1992-02-15

    Modulation of the electroosmotic flow in capillary zone electrophoresis by modulation of the driving voltage gives rise to a flow profile that changes between laminar and flat profiles. The changing flow profile induces a radial movement of sample species to and from the capillary surface. The induced sample concentration gradient can be monitored by carefully probing the capillary surface. The resulting signal is a derivative of the normal-shaped peak. Derivative-shaped peaks can be observed with cations, but not with anions. Anions are unable to approach the double-layer region and therefore are unaffected by the modulation process.

  18. Capillary interactions in Pickering emulsions

    Science.gov (United States)

    Guzowski, J.; Tasinkevych, M.; Dietrich, S.

    2011-09-01

    The effective capillary interaction potentials for small colloidal particles trapped at the surface of liquid droplets are calculated analytically. Pair potentials between capillary monopoles and dipoles, corresponding to particles floating on a droplet with a fixed center of mass and subjected to external forces and torques, respectively, exhibit a repulsion at large angular separations and an attraction at smaller separations, with the latter resembling the typical behavior for flat interfaces. This change of character is not observed for quadrupoles, corresponding to free particles on a mechanically isolated droplet. The analytical results are compared with the numerical minimization of the surface free energy of the droplet in the presence of spherical or ellipsoidal particles.

  19. Capillary thinning of polymeric filaments

    DEFF Research Database (Denmark)

    Kolte, Mette Irene; Szabo, Peter

    1999-01-01

    The capillary thinning of filaments of a Newtonian polybutene fluid and a viscoelastic polyisobutylene solution are analyzed experimentally and by means of numerical simulation. The experimental procedure is as follows. Initially, a liquid sample is placed between two cylindrical plates. Then, th...... and quantified. (C) 1999 The Society of Rheology. [S0148-6055(99)00103-0]....

  20. Ion guiding in alumina capillaries

    DEFF Research Database (Denmark)

    Juhász, Z.; Sulik, B.; Biri, S.

    2009-01-01

    Transmission of a few keV impact energy Ne ions through capillaries in anodic alumina membranes has been studied with different ion counting methods using an energy dispersive electrostatic spectrometer, a multichannel plate (MCP) array and sensitive current-measurement. In the present work, we...

  1. Filling of charged cylindrical capillaries

    NARCIS (Netherlands)

    Das, Siddhartha; Chanda, Sourayon; Eijkel, J.C.T.; Tas, N.R.; Chakraborty, Suman; Mitra, Sushanta K.

    2014-01-01

    We provide an analytical model to describe the filling dynamics of horizontal cylindrical capillaries having charged walls. The presence of surface charge leads to two distinct effects: It leads to a retarding electrical force on the liquid column and also causes a reduced viscous drag force because

  2. Capillary waves and ellipsometry experiments

    Science.gov (United States)

    Bonn, D.; Wegdam, G. H.

    1992-09-01

    The inclusion of higher-order terms in the capillary-wave Hamiltonian may reduce the contributions of these fluctuations to the ellipsometric coefficients. We show that the renormalization of capillary waves at a fluid-fluid interface by Sengers and van Leeuwen [Phys. Rev. A 39 (1989) 6346] using the wave vector-dependent surface tension that follows from the coupled mode theory by Meunier [Phys. France 48 (1987)1819] yields a satisfactory agreement with recent ellipsometry measurements by Schmidt [Phys. Rev. A 38 (1988) 567]. The interface is viewed upon as an intrinsic interface broadened by capillary waves. We suppose that the cutoff wave vector q_{max} that follows from mode-coupling theory marks the transition from the short-wavelength bulk-like fluctuations that contribute to the bare surface tension to the long-wavelength capillary wave-like fluctuations that contribute to the full surface tension. This enables us to calculate, without any adjustable parameters, both the ratio of the bare and experimental surface tension and the universal constant for the elliptical thickness of the interface. Both agree remarkably well with experimental values.

  3. Capillary wrinkling of thin bilayer polymeric sheets

    Science.gov (United States)

    Chang, Jooyoung; Menon, Narayanan; Russell, Thomas

    We have investigated capillary force induced wrinkling on a floated polymeric bilayer thin sheet. The origin of the wrinkle pattern is compressional hoop stress caused by the capillary force of a water droplet placed on the floated polymeric thin sheet afore investigated. Herein, we study the effect of the differences of surface energy arising from the hydrophobicity of Polystyrene (PS Mw: 97 K, Contact Angle: 88 º) and the hydrophilicity of Poly(methylmethacrylate) (PMMA Mw: 99K, Contact Angle: 68 º) on two sides of a bilayer film. We measure the number and the length of the wrinkles by broadly varying the range of thicknesses of top (9 nm to 550 nm) and bottom layer (25 nm to 330 nm). At the same, there is only a small contrast in mechanical properties of the two layers (PS E = 3.4 GPa, and PMMA E = 3 GPa). The number of the wrinkles is not strongly affected by the composition (PS(Top)/PMMA(Bottom) or PMMA(Top)/PS(Bottom)) and the thickness of each and overall bilayer system. However, the length of the wrinkle is governed by the contact angle of the drop on the top layer of bilayer system. We also compare this to the wrinkle pattern obtained in monolayer systems over a wide range of thickness from PS and PMMA (7 nm to 1 μm). W.M. Keck Foundation.

  4. Self-aligning subatmospheric hybrid liquid junction electrospray interface for capillary electrophoresis.

    Science.gov (United States)

    Krenkova, Jana; Kleparnik, Karel; Grym, Jakub; Luksch, Jaroslav; Foret, Frantisek

    2016-02-01

    We report a construction of a self-aligning subatmospheric hybrid liquid junction electrospray interface for CE eliminating the need for manual adjustment by guiding the capillaries in a microfabricated liquid junction glass chip at a defined angle. Both the ESI and separation capillaries are inserted into the microfabricated part until their ends touch. The distance between the capillary openings is defined by the angle between the capillaries. The microfabricated part contains channels for placement of the capillaries and connection of the external electrode reservoirs. It was fabricated using standard photolithographic/wet chemical etching techniques followed by thermal bonding. The liquid junction is connected to a subatmospheric electrospray chamber inducing the flow inside the ESI needle and helping the ion transport via aerodynamic focusing.

  5. DNA Sequencing Using capillary Electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Barry Karger

    2011-05-09

    The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other

  6. Interstitial capillary changes in lithium nephropathy: effects of antihypertensive treatment.

    Science.gov (United States)

    Skyum, Helle; Marcussen, Niels; Nielsen, Steen Horne; Christensen, Sten

    2004-10-01

    Histopathological changes were investigated in the tubulointerstitium and in the capillaries of male Wistar rats with lithium-induced nephropathy using stereological methods. Two antihypertensive drugs with opposite effects on the renin-angiotensin system, an ACE inhibitor (angiotensin converting enzyme inhibitor) and a thiazide diuretic, modified the nephropathy. Generally, there was a significant positive correlation between the reduction in GFR (glomerular filtration rate) and the reduction in the volume of intact tubular structures and interstitial capillaries. A significant negative correlation was seen between the reduction in GFR and the increase in tubulocapillary distance and the absolute volume of interstitial connective tissue, respectively. Treatment with perindopril, and to some extent hydrochlorothiazide, reversed the rise in systolic blood pressure associated with lithium-induced nephropathy but did not affect the progression to terminal uraemia, the structural renal changes or the mortality. In conclusion, severe tubular and capillary changes are seen in this model of chronic renal failure. Tubular atrophy is associated with a decrease in interstitial capillaries and with an increase in the tubulocapillary distance. Systemic hypertension or activation of the renin-angiotensin system may not be important factors for the progression to terminal renal failure.

  7. Stress failure of pulmonary capillaries: role in lung and heart disease

    Science.gov (United States)

    West, J. B.; Mathieu-Costello, O.

    1992-01-01

    Pulmonary capillaries have extremely thin walls to allow rapid exchange of respiratory gases across them. Recently it has been shown that the wall stresses become very large when the capillary pressure is raised, and in anaesthetised rabbits, ultrastructural damage to the walls is seen at pressures of 40 mm Hg and above. The changes include breaks in the capillary endothelial layer, alveolar epithelial layer, and sometimes all layers of the wall. The strength of the thin part of the capillary wall can be attributed to the type IV collagen in the extracellular matrix. Stress failure of pulmonary capillaries results in a high-permeability form of oedema, or even frank haemorrhage, and is apparently the mechanism of neurogenic pulmonary oedema and high-altitude pulmonary oedema. It also explains the exercise-induced pulmonary haemorrhage that occurs in all racehorses. Several features of mitral stenosis are consistent with stress failure. Overinflation of the lung also leads to stress failure, a common cause of increased capillary permeability in the intensive care environment. Stress failure also occurs if the type IV collagen of the capillary wall is weakened by autoantibodies as in Goodpasture's syndrome. Neutrophil elastase degrades type IV collagen and this may be the starting point of the breakdown of alveolar walls that is characteristic of emphysema. Stress failure of pulmonary capillaries is a hitherto overlooked and potentially important factor in lung and heart disease.

  8. Stress failure of pulmonary capillaries: role in lung and heart disease

    Science.gov (United States)

    West, J. B.; Mathieu-Costello, O.

    1992-01-01

    Pulmonary capillaries have extremely thin walls to allow rapid exchange of respiratory gases across them. Recently it has been shown that the wall stresses become very large when the capillary pressure is raised, and in anaesthetised rabbits, ultrastructural damage to the walls is seen at pressures of 40 mm Hg and above. The changes include breaks in the capillary endothelial layer, alveolar epithelial layer, and sometimes all layers of the wall. The strength of the thin part of the capillary wall can be attributed to the type IV collagen in the extracellular matrix. Stress failure of pulmonary capillaries results in a high-permeability form of oedema, or even frank haemorrhage, and is apparently the mechanism of neurogenic pulmonary oedema and high-altitude pulmonary oedema. It also explains the exercise-induced pulmonary haemorrhage that occurs in all racehorses. Several features of mitral stenosis are consistent with stress failure. Overinflation of the lung also leads to stress failure, a common cause of increased capillary permeability in the intensive care environment. Stress failure also occurs if the type IV collagen of the capillary wall is weakened by autoantibodies as in Goodpasture's syndrome. Neutrophil elastase degrades type IV collagen and this may be the starting point of the breakdown of alveolar walls that is characteristic of emphysema. Stress failure of pulmonary capillaries is a hitherto overlooked and potentially important factor in lung and heart disease.

  9. 毛细管电泳分离-激光诱导荧光检测巴氯芬和加巴喷丁%Determination of baclofen and gabapentin by capillary electrophoresis-laser-induced fluorescence method

    Institute of Scientific and Technical Information of China (English)

    曹丽伟; 李聪; 任东

    2011-01-01

    采用新合成的6-氧-(N-琥珀酰亚胺乙酸酯)-9-(2’-甲氧羰基)荧光素(SAMF)作为柱前衍生试剂,用甘氨酸做内标,毛细管电泳分离-激光诱导荧光检测血清中的巴氯芬(baclofen)和加巴喷丁(gabapentin).研究表明,在磷酸盐缓冲溶液(pH=8)介质中,25℃下15 min即可完成衍生反应.以pH =5的30 mmol/L的磷酸盐缓冲溶液作为电泳介质,衍生产物在16 min内达到电泳基线分离,检出限为4×10-10 mol/L.将新建立的方法用于血清中巴氯芬、加巴喷丁的分析测定,回收率为95.5% ~ 102.01%,结果令人满意.%A sensitive and efficient analysis method for determination of baclofen and gabapentin in human serum based on capillary electrophoresis with laser-induced fluorescence (LIF) has been established. 6-Oxy-( N-succinimidylacetate)- 9-(2'-Meth-oxycarbonyl) fluorescein (SAMF), a new synthesized fluorescence reagent, was used for pre-column derivatization of the "non-fluorescent drug in serum. Glycin was used as an internal standard. The best derivation condition was obtained in phosphate buffer (pH =8) at 25℃ for 15 min. Optimal separation and detection were obtained with an background electrolyte of 30 mmol/L phosphate buffer ( pH = 5 ) and LJF was excited at 473 nm. The detection limit of baclofen was 4 x 10-10 mol/L. This sensitive method was effectively used to determine baclofen and gabapentin in human serum with recoveries ranging from 95.5% to 102.01%.

  10. Environmental screening of acidic compounds based on capillary zone electrophoresis/laser-induced fluorescence detection with identification by gas chromatography/mass spectrometry and gas chromatography/high-resolution mass spectrometry.

    Science.gov (United States)

    Brumley, W C; Grange, A H; Kelliher, V; Patterson, D B; Montcalm, A; Glassman, J; Farley, J W

    2000-01-01

    This paper describes the application of capillary zone electrophoresis/laser-induced fluorescence detection (CZE/LIF) to the discovery of acidic compounds in environmental matrixes or the screening of extracts for acidic components. Published studies indicate that coal-derived materials contain a significant fraction of acidic compounds relative to materials derived from petroleum and shales. Such compounds may be useful as marker compounds for site assessment and source apportionment issues, and their identification may be important in toxicological and other health issues. We used deep-UV light from the frequency-doubled Ar ion laser at 244 and 257 nm to study extracts of samples. The CZE/LIF technique possesses good sensitivity and therefore overcomes one of the limitations of CZE with UV detection. The present work depends on high pressure/temperature solvent extraction of polynuclear aromatic hydrocarbon (PNA)-contaminated soil, followed by separation using CZE. The anionic analytes were separated by using borate or phosphate buffer (pH 9.2-12.3) after a chemical class separation. Samples were also characterized by gas chromatography/mass spectrometry (GC/MS) using full scans at low resolution, and elemental compositions were determined unequivocally by GC/high-resolution MS (GC/HRMS) using mass peak profiling (MPP). The similarity of low-resolution electron ionization mass spectra for a standard, 1-hydroxypyrene, and for a series of compounds in a contaminated-soil extract suggested that several types of phenolic and hydroxy-PNAs were present, including hydroxylated derivatives of fluorenes, fluoranthenes, and pyrenes. GC/HRMS using MPP confirmed the elemental compositions of the hydroxyfluorenes and hydroxypyrenes (and presumably hydroxyfluoranthenes) as [C13H10O] and [C16H10O], respectively. A new version of the MPP software was written for the Finnigan-MAT 900S-Trap and was similar to that developed previously for the VG 250SE. Inclusion of a calibration

  11. Assembly and function test of capillary electrotrophoresis-laser-induced fluorescence%毛细管电泳-激光诱导荧光分析仪组装与性能测试

    Institute of Scientific and Technical Information of China (English)

    余长柱; 姜同翠; 马云鹏; 吴婷妮; 李俊

    2012-01-01

    Aim To assemble a simple capillary electrotrophoresis-laser-induced fluorescence (CE-LIF) analyzer. Methods A 473-nm MBL-10 diode pumped solid-state laser was employed as an excitation source. The analytical system was based on the collinear optic configuration arrangement. VB2 was used as model compound to evaluate the analytical characteristics. Results The concentration detection limit (CLOD) and mass detection limit ( MLOD) of VB2 was 2.0 × 10-9 mol · L-1 (7.5 × 107g·L-1) and4.0 × 10-18mol(l. 5 × 10-15 g) , respectively. The linear calibration range was from 1.0 × 10-8 to 1.0 × 10-6 mol · L-1. Conlusion The home-made CE-LIF analyzer is simple to assemble and convenient to carry out,which has a very high detection sensitivity.%目的 组装一台毛细管电泳-激光诱导荧光分析仪.方法以473 nm半导体泵浦固体激光器为激发光源,自制的激光诱导荧光检测器采用共线型光学结构,用VB2为模型化合物进行该分析仪的性能评价.结果 VB2的浓度检出限为2.0×10-9 mol·L-1(7.5×10-7 g·L-1),质量检出限为4.0×10-18 mol(1.5×10-15 g),在1.0× 10-8 ~ 1.0×10-6 mol·L-1浓度范围内呈线性相关.结论 自组装毛细管电泳-激光诱导荧光分析仪具有结构简单,操作方便,灵敏度高等优点.

  12. Mixed Capillary Venous Retroperitoneal Hemangioma

    Directory of Open Access Journals (Sweden)

    Mohit Godar

    2013-01-01

    Full Text Available We report a case of mixed capillary venous hemangioma of the retroperitoneum in a 61-year-old man. Abdominal ultrasonography showed a mass to be hypoechoic with increased flow in color Doppler imaging. Dynamic contrast-enhanced computed tomography revealed a centripetal filling-in of the mass, located anterior to the left psoas muscle at the level of sacroiliac joint. On the basis of imaging features, preoperative diagnosis of hemangioma was considered and the mass was excised by laparoscopic method. Immunohistochemical studies were strongly positive for CD31 and CD34, and negative for calretinin, EMA, WT1, HMB45, Ki67, synaptophysin, and lymphatic endothelial cell marker D2–40. Histologically, the neoplasm was diagnosed as mixed capillary venous hemangioma.

  13. Capillary electrophoresis in food authenticity.

    Science.gov (United States)

    Kvasnicka, Frantisek

    2005-06-01

    Food authenticity is a term which simply refers to whether the food purchased by the consumer matches its description. False description can occur in many forms, from the undeclared addition of water or other cheaper materials, or the wrong declaration of the amount of a particular ingredient in the product, to making false statements about the source of ingredients i.e., their geographic, plant, or animal origin. The aim of this review is to summarize applications of capillary electrophoresis in food authentication.

  14. Analysis of neuropeptides using capillary zone electrophoresis with multichannel fluorescence detection

    Science.gov (United States)

    Sweedler, Jonathan V.; Shear, Jason B.; Fishman, Harvey A.; Zare, Richard N.; Scheller, Richard H.

    1991-12-01

    Capillary zone electrophoresis is fast becoming one of the most sensitive separation schemes for sampling complex microenvironments. A unique detection scheme is developed in which a charge-coupled device (CCD) detects laser induced fluorescence from an axially illuminated electrophoresis capillary. The fluorescence from an analyte band is measured over a several centimeter section of the capillary, greatly increasing the observation time of the fluorescently tagged band. The sensitivity of the system is in the 1-8 X 10-20 mol range for derivatized amino acids and peptides. Subattomole quantities of bag cell neuropeptides collected from the giant marine mollusk Aplysia californica can be measured.

  15. Enhanced solar evaporation of water from porous media, through capillary mediated forces and surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Canbazoglu, F. M.; Fan, B.; Kargar, A.; Vemuri, K.; Bandaru, P. R., E-mail: pbandaru@ucsd.edu [Department of Mechanical Engineering, University of California, San Diego, La Jolla, CA (United States)

    2016-08-15

    The relative influence of the capillary, Marangoni, and hydrophobic forces in mediating the evaporation of water from carbon foam based porous media, in response to incident solar radiation, are investigated. It is indicated that inducing hydrophilic interactions on the surface, through nitric acid treatment of the foams, has a similar effect to reduced pore diameter and the ensuing capillary forces. The efficiency of water evaporation may be parameterized through the Capillary number (Ca), with a lower Ca being preferred. The proposed study is of much relevance to efficient solar energy utilization.

  16. Enhanced solar evaporation of water from porous media, through capillary mediated forces and surface treatment

    Science.gov (United States)

    Canbazoglu, F. M.; Fan, B.; Kargar, A.; Vemuri, K.; Bandaru, P. R.

    2016-08-01

    The relative influence of the capillary, Marangoni, and hydrophobic forces in mediating the evaporation of water from carbon foam based porous media, in response to incident solar radiation, are investigated. It is indicated that inducing hydrophilic interactions on the surface, through nitric acid treatment of the foams, has a similar effect to reduced pore diameter and the ensuing capillary forces. The efficiency of water evaporation may be parameterized through the Capillary number (Ca), with a lower Ca being preferred. The proposed study is of much relevance to efficient solar energy utilization.

  17. Capillary Electrophoresis - Optical Detection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sepaniak, M. J.

    2001-08-06

    Molecular recognition systems are developed via molecular modeling and synthesis to enhance separation performance in capillary electrophoresis and optical detection methods for capillary electrophoresis. The underpinning theme of our work is the rational design and development of molecular recognition systems in chemical separations and analysis. There have been, however, some subtle and exciting shifts in our research paradigm during this period. Specifically, we have moved from mostly separations research to a good balance between separations and spectroscopic detection for separations. This shift is based on our perception that the pressing research challenges and needs in capillary electrophoresis and electrokinetic chromatography relate to the persistent detection and flow rate reproducibility limitations of these techniques (see page 1 of the accompanying Renewal Application for further discussion). In most of our work molecular recognition reagents are employed to provide selectivity and enhance performance. Also, an emerging trend is the use of these reagents with specially-prepared nano-scale materials. Although not part of our DOE BES-supported work, the modeling and synthesis of new receptors has indirectly supported the development of novel microcantilevers-based MEMS for the sensing of vapor and liquid phase analytes. This fortuitous overlap is briefly covered in this report. Several of the more significant publications that have resulted from our work are appended. To facilitate brevity we refer to these publications liberally in this progress report. Reference is also made to very recent work in the Background and Preliminary Studies Section of the Renewal Application.

  18. Self-Assembly of Cubes into 2D Hexagonal and Honeycomb Lattices by Hexapolar Capillary Interactions

    Science.gov (United States)

    Soligno, Giuseppe; Dijkstra, Marjolein; van Roij, René

    2016-06-01

    Particles adsorbed at a fluid-fluid interface induce capillary deformations that determine their orientations and generate mutual capillary interactions which drive them to assemble into 2D ordered structures. We numerically calculate, by energy minimization, the capillary deformations induced by adsorbed cubes for various Young's contact angles. First, we show that capillarity is crucial not only for quantitative, but also for qualitative predictions of equilibrium configurations of a single cube. For a Young's contact angle close to 90°, we show that a single-adsorbed cube generates a hexapolar interface deformation with three rises and three depressions. Thanks to the threefold symmetry of this hexapole, strongly directional capillary interactions drive the cubes to self-assemble into hexagonal or graphenelike honeycomb lattices. By a simple free-energy model, we predict a density-temperature phase diagram in which both the honeycomb and hexagonal lattice phases are present as stable states.

  19. Critical Capillary Number of Interfacial Film Displacement in a Capillary Tube

    CERN Document Server

    Yan, Changfei

    2016-01-01

    The role of surface tension and wettability in the dynamics of air-liquid interfaces during immiscible fluid displacement flows in capillary tube driven by pressure has been investigated. The contact angle and capillary number drive the force wetting processes which is controlled by the balance between the capillary and the viscous lubrication forces. The dynamic wetting condition with the critical capillary number is studied analytically and validated experimentally, which demonstrates that the critical capillary number is associated with the contact angle, slip length and capillary radius.

  20. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  1. Capillary/myocyte mismatch in the heart in renal failure--a role for erythropoietin?

    Science.gov (United States)

    Amann, K; Buzello, M; Simonaviciene, A; Miltenberger-Miltenyi, G; Koch, A; Nabokov, A; Gross, M L; Gless, B; Mall, G; Ritz, E

    2000-07-01

    Chronic renal failure is characterized by remodeling of the heart with left ventricular hypertrophy (increasing oxygen demand) and capillary deficit leading to capillary/myocyte mismatch (decreasing oxygen supply). Erythropoietin (Epo) has known angiogenic properties causing endothelial cell activation, migration and sprouting, mediated at least in part via the JAK/STAT (Janus kinase/signal transducers and activators of transcription) pathway. In uraemic cardiac hypertrophy the presence of diminished capillary supply implies that capillary growth does not keep pace with development of hypertrophy. To investigate whether this was due to a deficit of the angiogenic hormone Epo we examined whether Epo levels are altered and whether an increase in haematocrit by administration of rhEpo influences capillary supply, i.e. capillary/myocyte mismatch in experimental renal failure. Male Spraque-Dawley rats were either subjected to partial renal ablation or sham operation. Only modest amounts of renal tissue were removed so that the rats were not anemic. Subgroups of rats received either human (rh)Epo alone or in combination with unspecific antihypertensive treatment (dihydralazine plus furosemide) in order to control the Epo induced rise in blood pressure. Capillary supply was measured stereologically as capillary length per volume myocardium using the orientator method. Capillary length density was reduced by approximately 25% after partial renal ablation (3237+/-601 vs 4293+/-501 mm/mm(3) in controls). It was not statistically different in animals with partial renal ablation+rhEpo+antihypertensive treatment (3620+/-828 mm/mm(3)) compared to partial ablation alone. The study shows that lack of Epo does not cause, or contribute to, the deficit of capillary growth in the hypertrophied left ventricle of rats with renal failure. In addition, a rise in haematocrit is not accompanied by beneficial effects on alterations of cardiovascular structure in experimental renal failure.

  2. Investigation of the influence of capillary effect on operation of the loop heat pipe

    Directory of Open Access Journals (Sweden)

    Mikielewicz Dariusz

    2014-09-01

    Full Text Available In the paper presented are studies on the investigation of the capillary forces effect induced in the porous structure of a loop heat pipe using water and ethanol ad test fluids. The potential application of such effect is for example in the evaporator of the domestic micro-CHP unit, where the reduction of pumping power could be obtained. Preliminary analysis of the results indicates water as having the best potential for developing the capillary effect.

  3. DNA Sequencing Using capillary Electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Barry Karger

    2011-05-09

    The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other

  4. Measurement of Liquid Viscosities in Tapered or Parabolic Capillaries.

    Science.gov (United States)

    Ershov; Zorin; Starov

    1999-08-01

    The possibility of using tapered or parabolic capillaries for measurement of liquid viscosities is investigated both experimentally and theoretically. It is demonstrated that even small deviations in capillary radius from a constant value may substantially affect measurement results. Equations are derived which allow correct analysis of the measurement results in tapered or parabolic capillaries. The following cases are analyzed: a water imbibition into a tapered or parabolic capillary and displacement of one liquid by another immiscible liquid in tapered or parabolic capillaries. Two possibilities are considered: (a) the narrow end of the capillary as capillary inlet and (b) the wide end of the capillary as capillary inlet. Copyright 1999 Academic Press.

  5. A New Conductivity Detector for Capillary Electrophoresis

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new conductivity detector for capillary electrophoresis consisting of an electrochemical cell and a conductive meter was developed. In the cell, the microelectrode and capillary were inserted through the cell wall and fixed by screws and sealing ring, the ends of microelectrode and capillary were located by a guide with two cross holes. LOD for K+ was 1.5×10-5 mol/L.

  6. Intracranial capillary hemangioma mimicking a dissociative disorder

    Directory of Open Access Journals (Sweden)

    Alexander Lacasse

    2012-01-01

    Full Text Available Capillary hemangiomas, hamartomatous proliferation of vascular endothelial cells, are rare in the central nervous system (CNS. Intracranial capillary hemangiomas presenting with reversible behavioral abnormalities and focal neurological deficits have rarely been reported. We report a case of CNS capillary hemangioma presenting with transient focal neurological deficits and behavioral abnormalities mimicking Ganser’s syndrome. Patient underwent total excision of the vascular malformation, resulting in complete resolution of his symptoms.

  7. Oxygen exchange in silicone rubber capillaries.

    Science.gov (United States)

    Heineken, F G; Predecki, P K; Filley, G F

    1978-06-01

    Capillaries of 7 and 12.5 mu diameter have been fabricated in silicone rubber. Whole blood treated with heparin has been perfused through these capillaries. Under flowing conditions, no clotting or other clumping effects have been observed and red cells appear to maintain a constant velocity. Oxygen transfer data to and from saline perfusing the 12.5 mu diameter capillaries have been obtained in order to determine how rapidly O2 will permeate the silicone rubber film. The data indicate that the capillaries simulate lung tissue oxygen exchange and will allow for the first time the experimental determination of oxygen exchange kinetics in flowing whole blood.

  8. Slope wavenumber spectrum models of capillary and capillary-gravity waves

    Institute of Scientific and Technical Information of China (English)

    贾永君; 张杰; 王岩峰

    2010-01-01

    Capillary and capillary-gravity waves possess a random character, and the slope wavenumber spectra of them can be used to represent mean distributions of wave energy with respect to spatial scale of variability. But simple and practical models of the slope wavenumber spectra have not been put forward so far. In this article, we address the accurate definition of the slope wavenumber spectra of water surface capillary and capillary-gravity waves. By combining the existing slope wavenumber models and using th...

  9. Vacuum scanning capillary photoemission microscopy

    DEFF Research Database (Denmark)

    Aseyev, S.A.; Cherkun, A P; Mironov, B N

    2017-01-01

    of a gold reflecting layer on a compact disc which has been illuminated by an unfocused laser beam with a wavelength 400nm, from a femtosecond laser with a beam size of 4mm. A quartz capillary with a 2-µm aperture has been used in the experiments. The period of gold microstructure, shown to be 1.6µ...... distribution of the recorded photoelectrons consisted of periodic mountain-valley strips, resembling the surface profile of the sample. Submicron spatial resolution has been achieved. This approach paves the way to study pulsed photodesorption of large organic molecular ions with high spatial and element...

  10. Capillary electrophoresis theory and practice

    CERN Document Server

    Grossman, Paul D

    1992-01-01

    This book is designed to be a practical guide, used by wide audience, including those new to CE, those more experienced, routine users, those interested in technology development, and those involved with applications research. References have been emphasized to allow the reader to explore the detailed specifics and theoretical foundations.This book draws together the rapidly evolving, diverse, and multidisciplinary subject of capillary electrophoresis (CE). It is designed as a practical guide to be used by a wide audience, including those new to CE as well as more experienced users. T

  11. Electromigration dispersion in Capillary Electrophoresis

    CERN Document Server

    Chen, Zhen; 10.1007/s11538-011-9708-7

    2012-01-01

    In a previous paper (S. Ghosal and Z. Chen Bull. Math. Biol. 2010, vol. 72, pg. 2047) it was shown that the evolution of the solute concentration in capillary electrophoresis is described by a nonlinear wave equation that reduced to Burger's equation if the nonlinearity was weak. It was assumed that only strong electrolytes (fully dissociated) were present. In the present paper it is shown that the same governing equation also describes the situation where the electrolytic buffer consists of a single weak acid (or base). A simple approximate formula is derived for the dimensionless peak variance which is shown to agree well with published experimental data.

  12. A Novel Protocol to Analyze Short- and Long-Chain Fatty Acids Using Nonaqueous Microchip Capillary Electrophoresis

    Science.gov (United States)

    Cable, M. L.; Stockton, A. M.; Mora, Maria F; Willis, P. A.

    2013-01-01

    We propose a new protocol to identify and quantify both short- and long-chain saturated fatty acids in samples of astrobiological interest using non-aqueous microchip capillary electrophoresis (micronNACE) with laser induced fluorescence (LIF).

  13. Two-dimensional capillary origami

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, N.D., E-mail: nbrubaker@math.arizona.edu; Lega, J., E-mail: lega@math.arizona.edu

    2016-01-08

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  14. Mixed Fluid Conditions: Capillary Phenomena

    KAUST Repository

    Santamarina, Carlos

    2017-07-06

    Mixed fluid phenomena in porous media have profound implications on soil-atmosphere interaction, energy geotechnology, environmental engineering and infrastructure design. Surface tension varies with pressure, temperature, solute concentration, and surfactant concentration; on the other hand, the contact angle responds to interfacial tensions, surface topography, invasion velocity, and chemical interactions. Interfaces are not isolated but interact through the fluid pressure and respond to external fields. Jumps, snap-offs and percolating wetting liquids along edges and crevices are ubiquitous in real, non-cylindrical porous networks. Pore- and macroscale instabilities together with pore structure variability-and-correlation favor fluid trapping and hinder recovery efficiency. The saturation-pressure characteristic curve is affected by the saturation-history, flow-rate, the mechanical response of the porous medium, and time-dependent reactive and diffusive processes; in addition, there are salient differences between unsaturation by internal gas nucleation and gas invasion. Capillary forces add to other skeletal forces in the porous medium and can generate open-mode discontinuities when the capillary entry pressure is high relative to the effective stress. Time emerges as an important variable in mixed-fluid conditions and common quasi-static analyses may fail to capture the system response.

  15. Atomic Force Controlled Capillary Electrophoresis

    Science.gov (United States)

    Lewis, Aaron; Yeshua, Talia; Palchan, Mila; Lovsky, Yulia; Taha, Hesham

    2010-03-01

    Lithography based on scanning probe microscopic techniques has considerable potential for accurate & localized deposition of material on the nanometer scale. Controlled deposition of metallic features with high purity and spatial accuracy is of great interest for circuit edit applications in the semiconductor industry, for plasmonics & nanophotonics and for basic research in surface enhanced Raman scattering & nanobiophysics. Within the context of metal deposition we will review the development of fountain pen nanochemistry and its most recent emulation Atomic Force Controlled Capillary Electrophoresis (ACCE). Using this latter development we will demonstrate achievement of unprecedented control of nanoparticle deposition using a three-electrode geometry. Three electrodes are attached: one on the outside of a metal coated glass probe, one on the inside of a hollow probe in a solution containing Au nanoparticles in the capillary, and a third on the surface where the writing takes place. The three electrodes provide electrical pulses for accurate control of deposition and retraction of the liquid from the surface overcoming the lack of control seen in both dip pen lithography & fountain pen nanochemistry when the tip contacts the surface. With this development, we demonstrate depositing a single 1.3 nm Au nanoparticle onto surfaces such as semiconductors.

  16. Analysis of urinary drugs of abuse by a multianalyte capillary electrophoretic immunoassay.

    Science.gov (United States)

    Caslavska, J; Allemann, D; Thormann, W

    1999-04-09

    This paper characterizes a novel multianalyte competitive binding, electrokinetic capillary-based immunoassay for urinary methadone, opiates, benzoylecgonine (cocaine metabolite) and amphetamines. After incubation of 25 microliters urine with the reactants for several minutes in the presence of an internal standard, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein labelled drug tracers are monitored by capillary electrophoresis with on-column laser induced fluorescence detection. The multianalyte assay is shown to be rapid, simple, quantitative, capable of recognizing urinary drug concentrations > or = 30 ng/ml and suitable for screening of patient urines. Data are demonstrated to compare well with those obtained by routine screening methods based on enzyme multiplied immunoassay techniques and fluorescence polarization immunoassays. The electrokinetic capillary assay has been validated via analysis of external quality control urines and confirmation analysis of patient urines using GC-MS.

  17. Ultrasensitive quantification of cerebral capillary flow networks and dynamics

    Science.gov (United States)

    You, Jiang; Park, Ki; Du, Congwu; Pan, Yingtian

    2015-03-01

    Ultra-high resolution optical Doppler coherence tomography (μODT) is a promising tool for brain functional imaging. However, its sensitivity for detecting slow flows in capillary beds may limit its utility in visualizing and quantifying subtle changes in brain microcirculation. To address this limitation, we developed a novel method called contrast-enhanced μODT (c-μODT) in which intralipid is injected into mouse tail vein to enhance μODT detection sensitivity. We demonstrate that after intralipid injection, the flow detection sensitivity of μODT is dramatically enhanced by 230% as quantified by the fill factor (FF) of microvasculature. More importantly, we show that c-μODT preserves the quantitative properties for flow imaging, i.e., showing a comparable change ratio of hypercapnia-induced flow increase in the capillary network before and after injecting intralipid.

  18. Anomalous capillary filling and wettability reversal in nanochannels

    CERN Document Server

    Gravelle, Simon; Bocquet, Lydéric; Joly, Laurent

    2016-01-01

    This work revisits capillary filling dynamics in the regime of nanometric to subnanometric channels. Using molecular dynamics simulations of water in carbon nanotubes, we show that for tube radii below one nanometer, both the filling velocity and the Jurin rise vary non-monotonically with the tube radius. Strikingly, with fixed chemical surface properties, this leads to confinement-induced reversal of the tube wettability from hydrophilic to hydrophobic for specific values of the radius. By comparing with a model liquid metal, we show that these effects are not specific to water. Using complementary data from slit channels, we then show that they can be described using the disjoin-ing pressure associated with the liquid structuring in confinement. This breakdown of the standard continuum framework is of main importance in the context of capillary effects in nanoporous media, with potential interests ranging from membrane selectivity to mechanical energy storage.

  19. Modeling capillary forces for large displacements

    NARCIS (Netherlands)

    Mastrangeli, M.; Arutinov, G.; Smits, E.C.P.; Lambert, P.

    2014-01-01

    Originally applied to the accurate, passive positioning of submillimetric devices, recent works proved capillary self-alignment as effective also for larger components and relatively large initial offsets. In this paper, we describe an analytic quasi-static model of 1D capillary restoring forces tha

  20. Capillary waveguide optrodes for Medical applications

    Science.gov (United States)

    Kieslinger, Dietmar; Weigl, Bernhard H.; Draxler, Sonja; Lippitsch, Max E.

    1997-01-01

    Glass capillaries with a chemically sensitive coating on the inner surface are used as optical sensors for medical diagnostics. The capillary simultaneously serves as a sample compartment, a sensor element, and an inhomogeneous optical waveguide. Different optical setups have been investigated and compared regarding its waveguiding properties.

  1. Arrested segregative phase separation in capillary tubes

    NARCIS (Netherlands)

    Tromp, R. Hans; Lindhoud, Saskia

    2006-01-01

    Phase separation in a capillary tube with one of the phases fully wetting the capillary wall is arrested when the typical size of the phase domains reaches the value of the diameter of the tube. The arrested state consists of an alternating sequence of concave-capped and convex-capped cylindrical

  2. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    Science.gov (United States)

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.

    2014-06-17

    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

  3. Capillary electrophoresis using core-based hyperbranched polyethyleneimine (CHPEI) static-coated capillaries.

    Science.gov (United States)

    Boonyakong, Cheerapa; Tucker, Sheryl A

    2009-10-01

    With unique 3-D architecture, the application of core-based hyperbranched polyethyleneimine (CHPEI), as a capillary coating in capillary electrophoresis, is demonstrated by manipulation of the electroosmotic mobility (EOF). CHPEI coatings (CHPEI5, M(w) approximately 5000 and CHPEI25, M(w) approximately 25,000) were physically adsorbed onto the inner surface of bare fused-silica capillary (BFS) via electrostatic interaction of the oppositely charged molecules by rinsing the capillaries with different CHPEI aqueous solutions. The EOF values of the coated capillaries were measured over the pH range of 4.0-9.0. At higher pH (pH >6) the coated capillary surface possesses excess negative charges, which causes the reversal of the EOF. The magnitudes of the EOF obtained from the coated capillaries were three-fold lower than that of BFS capillary. Desirable reproducibility of the EOF with % RSD (n = 5) capillaries were successfully utilized to separate phenolic compounds, B vitamins, as well as basic drugs and related compounds with reasonable analysis time (capillary and capillary).

  4. Modulation in capillary electrophoresis and analysis of DNA

    Energy Technology Data Exchange (ETDEWEB)

    Demana, T.

    1992-01-01

    Analyte velocity modulation results when a sinusoidal AC voltage is superimposed onto the driving DC voltage. The principal motivation for the work has been exploration of voltage modulation as a technique is especially effective with excess noise limited detectors such as the refractive index detector. One advantage of an electrical modulation technique, over an optical one, is its applicability to all detection schemes. The mathematical theory of analyte velocity modulation is presented in this work. The main idea is that the superimposed AC field forces the electroosmotic flow profile to oscillate between laminar and plug flow at the modulation frequency. The changing profile induces a radial movement of sample species to and from the capillary surface. The induced sample concentration gradients can be monitored by carefully probing the capillary surface. The resulting signal is a derivative of the normal shaped peak. Derivative shaped peaks can be observed with cations, but not with anions. Anions are unable to approach the double layer region and therefore are unaffected by the modulation process. The results indicate that the double layer thickness in free solution capillary electrophoresis might be larger than the nominally calculated 3 nm. Analyte velocity modulation can be used as a variation of pulsed field electrophoresis in gel-filled capillaries. This technique provides superior resolution of DNA fragments and shortens their migration times. The authors demonstrate subpicogram detection limits for nucleic acids, with very high efficiencies. Theoretical plate numbers are in the range of 10[sup 5] to 10[sup 6]. They also demonstrate that sine wave modulation gives resolution similar to square wave modulation for frequencies between 10 and 100 Hz. Although a square wave contains high frequency harmonics, the authors show that in general its coupling to DNA motions is not always inferior to that of a sine wave.

  5. Capillary Separation: Micellar Electrokinetic Chromatography

    Science.gov (United States)

    Terabe, Shigeru

    2009-07-01

    Micellar electrokinetic chromatography (MEKC), a separation mode of capillary electrophoresis (CE), has enabled the separation of electrically neutral analytes. MEKC can be performed by adding an ionic micelle to the running solution of CE without modifying the instrument. Its separation principle is based on the differential migration of the ionic micelles and the bulk running buffer under electrophoresis conditions and on the interaction between the analyte and the micelle. Hence, MEKC's separation principle is similar to that of chromatography. MEKC is a useful technique particularly for the separation of small molecules, both neutral and charged, and yields high-efficiency separation in a short time with minimum amounts of sample and reagents. To improve the concentration sensitivity of detection, several on-line sample preconcentration techniques such as sweeping have been developed.

  6. Capillary Discharge XUV Radiation Source

    Directory of Open Access Journals (Sweden)

    M. Nevrkla

    2009-01-01

    Full Text Available A device producing Z-pinching plasma as a source of XUV radiation is described. Here a ceramic capacitor bank pulse-charged up to 100 kV is discharged through a pre-ionized gas-filled ceramic tube 3.2 mm in diameter and 21 cm in length. The discharge current has amplitude of 20 kA and a rise-time of 65 ns. The apparatus will serve as experimental device for studying of capillary discharge plasma, for testing X-ray optics elements and for investigating the interaction of water-window radiation with biological samples. After optimization it will be able to produce 46.9 nm laser radiation with collision pumped Ne-like argon ions active medium. 

  7. Two-dimensional capillary origami

    Science.gov (United States)

    Brubaker, N. D.; Lega, J.

    2016-01-01

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid.

  8. Gravity Capillary Standing Water Waves

    Science.gov (United States)

    Alazard, Thomas; Baldi, Pietro

    2015-09-01

    The paper deals with the 2D gravity-capillary water waves equations in their Hamiltonian formulation, addressing the question of the nonlinear interaction of a plane wave with its reflection off a vertical wall. The main result is the construction of small amplitude, standing (namely periodic in time and space, and not travelling) solutions of Sobolev regularity, for almost all values of the surface tension coefficient, and for a large set of time-frequencies. This is an existence result for a quasi-linear, Hamiltonian, reversible system of two autonomous pseudo-PDEs with small divisors. The proof is a combination of different techniques, such as a Nash-Moser scheme, microlocal analysis and bifurcation analysis.

  9. Effect of Fluorosurfactant on Capillary Instabilities in Nanoimprinted Polymer Patterns

    Energy Technology Data Exchange (ETDEWEB)

    Alvine, Kyle J.; Ding, Yifu; Douglas, Jack F.; Ro, Hyun W.; Okerberg, Brian C.; Karim, Alamgir; Lavery, Kristopher A.; Lin-Gibson, Sheng; Soles, Christopher L.

    2009-12-15

    Surface forces play a paramount role in most aspects of Nanoimprint Lithography. In particular, subjecting nanoimprinted patterns to moderate heating allows surface tension to smooth out undesirable roughness and defects in the patterns, but this thermal reflow treatment can induce structural decay or even collapse of the patterns by capillary instability if this process is not carefully controlled. Adhesion between the mold and polymer film can also cause the imprinted structure to tear or fracture. Fluorinated surfactants (FS) are attractive for reducing mold adhesion, yet the effects of these additives on nanostructure stability during thermal reflow are not well understood. Here we present thermal stability studies of line-space grating patterns created by Thermal Embossing Nanoimprint Lithography (TENIL) on model polystyrene (PS) films with FS additives. As expected by energy considerations, FS segregates to the air interface where it seems to facilitate mold release. This also reduces the surface energy and thus reduces the driving force for pattern "slumping" (height decay). However, the beneficial effects of the surfactant are counterbalanced by the fact that the FS decreases the effective film viscosity, which accelerates nanopattern leveling. The net effect is that the pattern height decay is strongly a function of FS concentration. This enhanced film fluidity in the presence of FS also makes the pattern more susceptible to an undulatory capillary instability under thermal reflow conditions. Surface phase segregation of FS and PS is also observed in conjunction with both slumping and lateral capillary instabilities, which may be useful for producing chemically patterned surfaces.

  10. Liquid morphologies and capillary forces between three spherical beads

    Science.gov (United States)

    Semprebon, Ciro; Scheel, Mario; Herminghaus, Stephan; Seemann, Ralf; Brinkmann, Martin

    2016-07-01

    Equilibrium shapes of coalesced pendular bridges in a static assembly of spherical beads are computed by numerical minimization of the interfacial energy. Our present study focuses on generic bead configurations involving three beads, one of which is in contact to the two others while there is a gap of variable size between the latter. In agreement with previous experimental studies, we find interfacial "trimer" morphologies consisting of three coalesced pendular bridges, and "dimers" of two coalesced bridges. In a certain range of the gap opening we observe a bistability between the dimer and trimer morphology during changes of the liquid volume. The magnitude of the corresponding capillary forces in presence of a trimer or dimer depends, besides the gap opening, only on the volume or Laplace pressure of the liquid. For a given Laplace pressure, and for the same gap opening, the capillary forces induced by a trimer are only slightly larger than the corresponding forces in the presence of three pendular bridges. This observation is consistent with a plateau of capillary cohesion in terms of the saturation of a wetting liquid in the funicular regime, as reported in the experimental work [Scheel et al., Nat. Mater. 7, 189 (2008), 10.1038/nmat2117].

  11. 3D Printing by Multiphase Silicone/Water Capillary Inks.

    Science.gov (United States)

    Roh, Sangchul; Parekh, Dishit P; Bharti, Bhuvnesh; Stoyanov, Simeon D; Velev, Orlin D

    2017-08-01

    3D printing of polymers is accomplished easily with thermoplastics as the extruded hot melt solidifies rapidly during the printing process. Printing with liquid polymer precursors is more challenging due to their longer curing times. One curable liquid polymer of specific interest is polydimethylsiloxane (PDMS). This study demonstrates a new efficient technique for 3D printing with PDMS by using a capillary suspension ink containing PDMS in the form of both precured microbeads and uncured liquid precursor, dispersed in water as continuous medium. The PDMS microbeads are held together in thixotropic granular paste by capillary attraction induced by the liquid precursor. These capillary suspensions possess high storage moduli and yield stresses that are needed for direct ink writing. They could be 3D printed and cured both in air and under water. The resulting PDMS structures are remarkably elastic, flexible, and extensible. As the ink is made of porous, biocompatible silicone that can be printed directly inside aqueous medium, it can be used in 3D printed biomedical products, or in applications such as direct printing of bioscaffolds on live tissue. This study demonstrates a number of examples using the high softness, elasticity, and resilience of these 3D printed structures. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration

    Science.gov (United States)

    Watenpaugh, Donald E.; Vissing, Susanne F.; Lane, Lynda D.; Buckey, Jay C.; Firth, Brian G.; Erdman, William; Hargens, Alan R.; Blomqvist, C. Gunnar

    1995-01-01

    Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethys-mography of supine health male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n equals 6) and during placebo infusion (n equals 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 plus or minus 4 to 2,568 plus or minus 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion; mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3 percent respectively, relative to pre-infusion baseline values (p is less than 0.05). Mean calf filtration, however was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20 percent with ANP infusion, wheras blood pressure was unchanged. Calf conductance (blood flow/arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, phamacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchic sites or both, while having the opposite effect in the leg.

  13. Synergistic effects of geometry, inertia, and dynamic contact angle on wetting and dewetting of capillaries of varying cross sections.

    Science.gov (United States)

    Wang, Qiuling; Graber, Ellen R; Wallach, Rony

    2013-04-15

    Understanding the role of geometry, inertia, and dynamic contact angle on wetting and dewetting of capillary tubes has theoretical and practical aspects alike. The specific and synergistic effects of these factors were studied theoretically using a mathematical model that includes inertial and dynamic contact angle terms. After validating the model for capillaries of uniform cross section, the model was extended to capillaries with sinusoidal modulations of the radius, since in practice, capillaries rarely have uniform cross-sections. The height of the meniscus during wetting and dewetting was significantly affected by the relations between the local slope of the capillary surface and the Young contact angle. Non-dimensional variables were defined using viscous effects and gravity as the scaling parameters. Simulations using the dimensionless model showed that the inertial and dynamic contact angle terms can be neglected for narrow capillaries of uniform cross-section but not for uniform, wide cross-section capillaries. Moreover, nonuniformity in cross-sectional area induced hysteresis, deceleration, blocking, and metastable equilibrium locations. An increase in contact angle further amplified the effect of geometry on wetting and dewetting processes. These results enable characterization and modeling of fluid retention and flow in porous structures that inherently consist of capillaries of varying cross section.

  14. Neutrophil crawling in capillaries; a novel immune response to Staphylococcus aureus.

    Science.gov (United States)

    Harding, Mark Geoffrey; Zhang, Kunyan; Conly, John; Kubes, Paul

    2014-10-01

    Methicillin-resistant Staphylococcus aureus (MRSA), particularly the USA300 strain, is a highly virulent pathogen responsible for an increasing number of skin and soft tissue infections globally. Furthermore, MRSA-induced soft tissue infections can rapidly progress into life-threatening conditions, such as sepsis and necrotizing fasciitis. The importance of neutrophils in these devastating soft tissue infections remains ambiguous, partly because of our incomplete understanding of their behaviour. Spinning disk confocal microscopy was used to visualize the behaviour of GR1-labelled neutrophils in subcutaneous tissue in response to GFP-expressing MRSA attached to a foreign particle (agarose bead). We observed significant directional neutrophil recruitment towards the S. aureus agarose bead but not a control agarose bead. A significant increase in neutrophil crawling within the capillaries surrounding the infectious nidus was noted, with impaired capillary perfusion in these vessels and increased parenchymal cell death. No neutrophils were able to emigrate from capillaries. The crawling within these capillaries was mediated by the β(2) and α(4) integrins and blocking these integrins 2 hours post infection eliminated neutrophil crawling, improved capillary perfusion, reduced cell death and reduced lesion size. Blocking prior to infection increased pathology. Neutrophil crawling within capillaries during MRSA soft tissue infections, while potentially contributing to walling off or preventing early dissemination of the pathogen, resulted in impaired perfusion and increased tissue injury with time.

  15. Periocular capillary hemangioma: management practices in recent years

    Directory of Open Access Journals (Sweden)

    Hernandez JA

    2013-06-01

    Full Text Available Jo Anne Hernandez,1,3,4 Audrey Chia,2 Boon Long Quah,1,2 Lay Leng Seah1,2 1Department of Ophthalmology, Kandang Kerbau Women's and Children's Hospital, Singapore; 2Singapore National Eye Centre, Singapore; 3National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore; 4Department of Ophthalmology, Cardinal Santos Medical Center, San Juan, Manila, Philippines Purpose: To present a case series on the management options for capillary hemangiomas involving the eyelid and orbit. Methods: This is a retrospective chart review of clinically diagnosed capillary hemangioma cases involving the periocular region treated at two local eye institutions. The patients' demographics and clinical presentation – including visual acuity, refractive error, periorbital and orbital examinations, and ultrasound and magnetic resonance imaging findings – were reviewed. The clinical progression, modalities of treatment, and treatment outcomes were studied. Results: Sixteen cases of capillary hemangiomas involving the eyelid and orbit were studied. The mean age at consultation was 9.6 months (range: 1 month–72 months. The majority were females (75%, with 50% presenting as upper-eyelid hemangiomas and the remaining as lower-eyelid (38% and glabellar (12% lesions. Combined superficial and deep involvement was common (64%. Cases whose lesions were located at the upper eyelid or superior orbit led to amblyopia (25%. Fifty-six percent of cases (9/16 were managed conservatively, and 44% (7/16 underwent treatment with either single-agent (n = 4 or combined treatments (n = 3. Conclusion: Close monitoring of visual development and prompt institution of amblyopia therapy for children with periocular capillary hemangiomas generally preserve vision. Extensive lesions that affect the visual axis require local and systemic treatments, alone or in combination, in order to reduce the size and impact of lesions on the eyeball, to reduce induced refractive error and

  16. Thermal expansion pump for capillary high-performance liquid chromatography.

    Science.gov (United States)

    Tao, Qian; Wu, Qian; Zhang, Xiangmin

    2010-02-01

    A thermal expansion pump (TEP) based on a principle of liquid thermal expansion for capillary high-performance liquid chromatography has been developed. The novel pump is capable of generating a continuous flow at high pressure for constant and stable delivery of binary solvents from nanoliters to microliters per minute without splitting. Theoretical equations for controlling fluidic output of this pump have been established and validated by a series of experiments. Factors affecting flow rate, such as density discrepancy, liquid compressibility, and mass loss in output, were taken into account. An assembly of the pump system employing two groups of thermal expansion pumps (TEPs) working in turns were fabricated, and a controlling strategy for the pump system to maintain a continuous delivery without pressure fluctuation even at switching points was also developed. Both isocratic and gradients of binary solvent delivery by the TEPs were performed. Reproducibility and standard deviation at different flow rates were determined. A capillary high-performance liquid chromatography (micro-HPLC) system consisting of the TEPs, an injection valve, a homemade packed capillary column (20 cm x 100 microm i.d. with 5 microm C18), and a laser-induced fluorescence detector was set up, and sample separations were carried out. Results of RSD = 4% for flow and RSD = 2% for retention times at 500 nL/min were achieved. Such a pump system has almost no moving parts except for the solvent switches. Its overall costs of manufacture and running are very low. It is proven that the TEPs system has great potential and competitive capabilities in capillary liquid chromatography.

  17. Numerical Simulation of Unsteady Blood Flow through Capillary Networks.

    Science.gov (United States)

    Davis, J M; Pozrikidis, C

    2011-08-01

    A numerical method is implemented for computing unsteady blood flow through a branching capillary network. The evolution of the discharge hematocrit along each capillary segment is computed by integrating in time a one-dimensional convection equation using a finite-difference method. The convection velocity is determined by the local and instantaneous effective capillary blood viscosity, while the tube to discharge hematocrit ratio is deduced from available correlations. Boundary conditions for the discharge hematocrit at divergent bifurcations arise from the partitioning law proposed by Klitzman and Johnson involving a dimensionless exponent, q≥1. When q=1, the cells are partitioned in proportion to the flow rate; as q tends to infinity, the cells are channeled into the branch with the highest flow rate. Simulations are performed for a tree-like, perfectly symmetric or randomly perturbed capillary network with m generations. When the tree involves more than a few generations, a supercritical Hopf bifurcation occurs at a critical value of q, yielding spontaneous self-sustained oscillations in the absence of external forcing. A phase diagram in the m-q plane is presented to establish conditions for unsteady flow, and the effect of various geometrical and physical parameters is examined. For a given network tree order, m, oscillations can be induced for a sufficiently high value of q by increasing the apparent intrinsic viscosity, decreasing the ratio of the vessel diameter from one generation to the next, or by decreasing the diameter of the terminal vessels. With other parameters fixed, oscillations are inhibited by increasing m. The results of the continuum model are in excellent agreement with the predictions of a discrete model where the motion of individual cells is followed from inlet to outlet.

  18. PCR-SSCP analysis of p16 gene mutation by capillary electrophoresis with laser-induced fluorescence detector%毛细管电泳PCR-SSCP分析p16基因突变

    Institute of Scientific and Technical Information of China (English)

    吴逸明; 张振中; 史香林

    2000-01-01

    @@ Lung cancer is one of the most common cancers in the world. Some genetic alterations such as p53 gene and ras gene mutations, have been identified in this disease. Recently, a putative tumor suppressor gene, the p16/CDKN2/MTS1 gene containing 3 extrons and 2 introns, located in the chromosome p21 region, was cloned independently by three research groups. Traditionally, gene mutation analysis was performed by slab polyacrylamide gel electrophoresis. However, this method is laborious, time-consuming, low sensitivity and harmful to human health. Capillary electrophoresis (CE) with the characteristics of rapidity and high performance has numerous advantages over conventional slab polyacrylamide gel electrophoresis. An important advantage of CE is that the commercially available system is automation.

  19. Nanoparticle-based capillary electroseparation of proteins in polymer capillaries under physiological conditions

    DEFF Research Database (Denmark)

    Nilsson, C.; Harwigsson, I.; Becker, K.

    2010-01-01

    Totally porous lipid-based liquid crystalline nanoparticles were used as pseudostationary phase for capillary electroseparation with LIF detection of proteins at physiological conditions using unmodified cyclic olefin copolymer capillaries (Topas (R), 6.7 cm effective length). In the absence...... at protein friendly conditions. The developed capillary-based method facilitates future electrochromatography of proteins on polymer-based microchips under physiological conditions and enables the initial optimization of separation conditions in parallel to the chip development....

  20. CAPILLARY ELECTROPHORETIC BEHAVIOR OF SEVEN SULFONYLUREAS

    Science.gov (United States)

    The electrophoretic behavior of bensulfuron Me, sulfometuron Me, nicosulfuron (Accent), chlorimuron Et, thifensulfuron Me (Harmony), metsulfuron Me, and chlorsulfuron was studied under capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) conditio...

  1. Capillary electrochromatography using fibers as stationary phases.

    Science.gov (United States)

    Jinno, K; Watanabe, H; Saito, Y; Takeichi, T

    2001-10-01

    Fiber-packed capillary columns have been evaluated in chromatographic performance in capillary electrochromatography (CEC). The change of electroosmotic flow (EOF) velocity and selectivity using different kinds of fiber materials was examined. Although the EOF velocity among the different fiber packed columns was almost the same, retention of parabens was larger on the Kevlar-packed column than on the Zylon-packed one, and was larger on the as-span-type fiber-packed column than on the high-modulus-type packed one. Using 200 microm ID x 5 cm Kevlar packed column combined with a 100 microm ID x 20 cm precolumn capillary and a 530 microm ID x 45 cm postcolumn capillary, the separation of three parabens within 30 s was achieved. Other compounds were also separated in a few minutes by the fiber-packed CEC method.

  2. Capillary detectors for high resolution tracking

    CERN Document Server

    Annis, P

    1997-01-01

    We present a new tracking device based on glass capillary bundles or layers filled with highly purified liquid scintillator and read out at one end by means of image intensifiers and CCD devices. A large-volume prototype consisting of 5 × 105 capillaries with a diameter of 20 μm and a length of 180 cm and read out by a megapixel CCD has been tested with muon and neutrino beams at CERN. With this prototype a two track resolution of 33 μm was achieved with passing through muons. Images of neutrino interactions in a capillary bundle have also been acquired and analysed. Read-out chains based on Electron Bombarded CCD (EBCCD) and image pipeline devices are also investigated. Preliminary results obtained with a capillary bundle read out by an EBCCD are presented.

  3. Cycloaliphatic epoxy resin coating for capillary electrophoresis.

    Science.gov (United States)

    Shah, Roopa S; Wang, Qinggang; Lee, Milton L

    2002-04-05

    Coating the interior surface of a fused-silica capillary with a polymeric material has long been used in capillary electrophoresis (CE) to reduce or eliminate electroosmotic flow and suppress adsorption. A cycloaliphatic epoxide-based resin was bonded to silane treated capillaries and crosslinked with a curing agent. The epoxy resin coating significantly reduced electroosmotic flow over a pH range of 3-10. This coating was sufficiently hydrophilic to suppress protein adsorption. The epoxy resin coated capillary was used to separate several acidic and basic proteins and peptides. Separation efficiencies greater than 400,000 theoretical plates were achieved. The relative standard deviations in migration times for proteins were methods.

  4. Uptake of water droplets by nonwetting capillaries

    CERN Document Server

    Willmott, Geoff R; Hendy, Shaun C

    2010-01-01

    We present direct experimental evidence that water droplets can spontaneously penetrate non-wetting capillaries, driven by the action of Laplace pressure due to high droplet curvature. Using high-speed optical imaging, microcapillaries of radius 50 to 150 micron, and water microdroplets of average radius between 100 and 1900 micron, we demonstrate that there is a critical droplet radius below which water droplets can be taken up by hydrophobised glass and polytetrafluoroethylene (PTFE) capillaries. The rate of capillary uptake is shown to depend strongly on droplet size, with smaller droplets being absorbed more quickly. Droplet size is also shown to influence meniscus motion in a pre-filled non-wetting capillary, and quantitative measurements of this effect result in a derived water-PTFE static contact angle between 96 degrees and 114 degrees. Our measurements confirm recent theoretical predictions and simulations for metal nanodroplets penetrating carbon nanotubes (CNTs). The results are relevant to a wide ...

  5. Capillary Optics generate stronger X-rays

    Science.gov (United States)

    1996-01-01

    NASA scientist, in the Space Sciences lab at Marshall, works with capillary optics that generate more intense X-rays than conventional sources. This capability is useful in studying the structure of important proteins.

  6. Applicability of chemically modified capillaries in chiral capillary electrophoresis for methamphetamine profiling.

    Science.gov (United States)

    Iwata, Yuko T; Mikuma, Toshiyasu; Kuwayama, Kenji; Tsujikawa, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Inoue, Hiroyuki

    2013-03-10

    We examined the applicability of chemically modified capillaries on the chiral capillary electrophoresis of essential compounds for methamphetamine (MA) profiling (MA, amphetamine, ephedrine, pseudoephedrine, norephedrine, and norpseudoephedrine) using highly sulfated γ-cyclodextrin as a chiral selector. Four types of chemically modified capillaries, namely, FunCap-CE/Type D (possessing diol groups), Type A (amino groups), Type C (carboxyl groups), and Type S (sulfate groups), were evaluated. Repeatability, speed, and good chiral resolution sufficient for routine MA profiling were achieved with the Type S capillary.

  7. Unusual intraosseous capillary hemangioma of the mandible.

    Science.gov (United States)

    Dereci, Omur; Acikalin, Mustafa Fuat; Ay, Sinan

    2015-01-01

    Intraosseous hemangioma is a benign vascular neoplasm, which is mostly seen in vertebrae, maxillofacial bones, and long bones. Intraosseous hemangioma is rarely seen on jaw bones compared to other skeletal bones and usually occurs in the cavernous form. Capillary intraosseous hemangioma of jaws is an uncommon form of intraosseous hemangioma and has not been thoroughly described so far. In this study, a case of capillary intraosseous hemangioma of the mandible was presented with relevant literature review.

  8. Unusual intraosseous capillary hemangioma of the mandible

    OpenAIRE

    Dereci, Omur; Acikalin, Mustafa Fuat; Ay, Sinan

    2015-01-01

    Intraosseous hemangioma is a benign vascular neoplasm, which is mostly seen in vertebrae, maxillofacial bones, and long bones. Intraosseous hemangioma is rarely seen on jaw bones compared to other skeletal bones and usually occurs in the cavernous form. Capillary intraosseous hemangioma of jaws is an uncommon form of intraosseous hemangioma and has not been thoroughly described so far. In this study, a case of capillary intraosseous hemangioma of the mandible was presented with relevant liter...

  9. Unusual intraosseous capillary hemangioma of the mandible

    OpenAIRE

    Dereci, Omur; ACIKALIN, Mustafa Fuat; AY, Sinan

    2015-01-01

    Intraosseous hemangioma is a benign vascular neoplasm, which is mostly seen in vertebrae, maxillofacial bones, and long bones. Intraosseous hemangioma is rarely seen on jaw bones compared to other skeletal bones and usually occurs in the cavernous form. Capillary intraosseous hemangioma of jaws is an uncommon form of intraosseous hemangioma and has not been thoroughly described so far. In this study, a case of capillary intraosseous hemangioma of the mandible was presented with relevant liter...

  10. Capillary effects in guided crystallization of organic thin films

    Directory of Open Access Journals (Sweden)

    Alta Fang

    2015-03-01

    Full Text Available Recently, it has been demonstrated that solvent-vapor-induced crystallization of triethylsilylethynyl anthradithiophene (TES ADT thin films can be directed on millimeter length scales along arbitrary paths by controlling local crystal growth rates via pre-patterning the substrate. Here, we study the influence of capillary effects on crystallization along such channels. We first derive an analytical expression for the steady-state growth front velocity as a function of channel width and validate it with numerical simulations. Then, using data from TES ADT guided crystallization experiments, we extract a characteristic channel width, which provides the smallest feature size that can be obtained by this technique.

  11. Subtracting Technique of Baselines for Capillary Electrophoresis Signals

    Institute of Scientific and Technical Information of China (English)

    WANG Ying; MO Jin-yuan; CHEN Zuan-guang; GAO Yan

    2004-01-01

    The drifting baselines of capillary electrophoresis affect the veracity of analysis greatly. This paper presents Threshold Fitting Technique(TFT) so as to subtract the baselines from the original signals and emendate the signals. In TFT, wav elet and curve fitting technique are applied synthetically, thresholds are decided by the computer automatically. Many experiments of signal processing indicate that TFT is simple for being used, there are few man-induced factors, and the results are satisfactory. TFT can be applied for noisy signals without any pre-processing.

  12. Ultrastructure and histochemistry of rat myocardial capillary endothelial cells in response to diabetes and hypertension

    Institute of Scientific and Technical Information of China (English)

    Ludmila OKRUHLICOVA; Narcis TRIBULOVA; Peter WEISMANN; Ruzena SOTNIKOVA

    2005-01-01

    Insufficient growth and rarefaction of capillaries,followed by endothelial dysfunction may represent one of the most critical mechanisms involved in heart damage.In this study we examined histochemical and ultrastructural changes in myocardial capillary endothelium in two models of heart failure streptozotocin-induced diabetes mellitus (STZ) and NOdeficient hypertension in male Wistar rats.Diabetes was induced by a single i.v.dose of STZ (45 mg/kg) and chronic 9-week stage was analysed.To induce NO-deficient hypertension,animals were treated with inhibitor of NO synthase Lnitroarginine methylester (L-NAME) (40 mg/kg) for 4 weeks.Left ventricular tissue was processed for enzyme catalytic histochemistry of capillary alkaline phosphatase (AlPh),dipeptidyl peptidase Ⅳ (DPP Ⅳ),and endothelial NO synthase/NADPH-diaphorase (NOS) and for ultrastructural analysis.In diabetic and hypertensive rats,lower/absent AlPh and DPP Ⅳ activities were found in focal micro-areas.NOS activity was significantly reduced and persisted only locally.Quantitative evaluation demonstrated reduction of reaction product intensity of AlPh,DPP and NOS by 49.50%,74.36%,20.05% in diabetic and 62.93%,82.71%,37.65% in hypertensive rats.Subcellular alterations of endothelial cells were found in heart of both groups suggesting injury of capillary function as well as compensatory processes.Endothelial injury was more significant in diabetic animals,in contrast the adaptation was more evident in hypertensive ones.Concluding: both STZ-induced diabetes- and NO-deficient hypertension-related cardiomyopathy were accompanied by similar features of structural remodelling of cardiac capillary network manifested as angiogenesis and angiopathy.The latter was however,predominant and may accelerate disappearance of capillary endothelium contributing to myocardial dysfunction.

  13. Cell adhesion during bullet motion in capillaries.

    Science.gov (United States)

    Takeishi, Naoki; Imai, Yohsuke; Ishida, Shunichi; Omori, Toshihiro; Kamm, Roger D; Ishikawa, Takuji

    2016-08-01

    A numerical analysis is presented of cell adhesion in capillaries whose diameter is comparable to or smaller than that of the cell. In contrast to a large number of previous efforts on leukocyte and tumor cell rolling, much is still unknown about cell motion in capillaries. The solid and fluid mechanics of a cell in flow was coupled with a slip bond model of ligand-receptor interactions. When the size of a capillary was reduced, the cell always transitioned to "bullet-like" motion, with a consequent decrease in the velocity of the cell. A state diagram was obtained for various values of capillary diameter and receptor density. We found that bullet motion enables firm adhesion of a cell to the capillary wall even for a weak ligand-receptor binding. We also quantified effects of various parameters, including the dissociation rate constant, the spring constant, and the reactive compliance on the characteristics of cell motion. Our results suggest that even under the interaction between P-selectin glycoprotein ligand-1 (PSGL-1) and P-selectin, which is mainly responsible for leukocyte rolling, a cell is able to show firm adhesion in a small capillary. These findings may help in understanding such phenomena as leukocyte plugging and cancer metastasis. Copyright © 2016 the American Physiological Society.

  14. Ion guiding in curved glass capillaries

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Takao M. [Atomic Physics Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Ikeda, Tokihiro [Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Kanai, Yasuyuki; Yamazaki, Yasunori [Atomic Physics Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)

    2015-07-01

    Straight and curved glass capillaries were tested for the guiding of 8 keV Ar{sup 8+} ion beams. The straight capillary was about 50 mm long and 0.87 mm/1.1 mm in inner/outer diameter. One of the two curved capillaries was similar, but was curved with a 270 mm radius. The other was 53 mm long, had diameters of 2.34 mm/2.99 mm, and was curved with a 150 mm radius. The corresponding bending angles of the two curved capillaries were 9.6° and 17.5°, respectively. Transmission through the straight capillary disappeared when the tilt angle was larger than 5°. The curved capillaries guided the ion beams into their corresponding bending angles, which were much larger than 5°, with transmission efficiencies of a few tens percent. This demonstrates the possibility of developing a new scheme of simple small beam deflectors and related beam optics.

  15. A capillary viscometer designed for the characterization of biocompatible ferrofluids

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, J., E-mail: johannes.nowak@tu-dresden.de; Odenbach, S.

    2016-08-01

    Suspensions of magnetic nanoparticles are receiving a growing interest in biomedical research. These ferrofluids can, e.g., be used for the treatment of cancer, making use of the drug targeting principle or using an artificially induced heating. To enable a safe application the basic properties of the ferrofluids have to be well understood, including the viscosity of the fluids if an external magnetic field is applied. It is well known that the viscosity of ferrofluids rises if a magnetic field is applied, where the rise depends on shear rate and magnetic field strength. In case of biocompatible ferrofluids such investigations proved to be rather complicated as the experimental setup should be close to the actual application to allow justified predictions of the effects which have to be expected. Thus a capillary viscometer, providing a flow situation comparable to the flow in a blood vessel, has been designed. The glass capillary is exchangeable and different inner diameters can be used. The range of the shear rates has been adapted to the range found in the human organism. The application of an external magnetic field is enabled with two different coil setups covering the ranges of magnetic field strengths required on the one hand for a theoretical understanding of particle interaction and resulting changes in viscosity and on the other hand for values necessary for a potential biomedical application. The results show that the newly designed capillary viscometer is suitable to measure the magnetoviscous effect in biocompatible ferrofluids and that the results appear to be consistent with data measured with rotational rheometry. In addition, a strong change of the flow behaviour of a biocompatible ferrofluid was proven for ranges of the shear rate and the magnetic field strength expected for a potential biomedical application. - Highlights: • A capillary viscometer to characterize biocompatible ferrofluids is presented. • Shear rates and capillary diameters

  16. Impaired skin capillary recruitment in essential hypertension is caused by both functional and structural capillary rarefaction

    NARCIS (Netherlands)

    Serne, EH; Gans, ROB; ter Maaten, JC; Tangelder, GJ; Donker, AJM; Stehouwer, CDA

    2001-01-01

    Capillary rarefaction occurs in many tissues in patients with essential hypertension and may contribute to an increased vascular resistance and impaired muscle metabolism. Rarefaction may be caused by a structural (anatomic) absence of capillaries, functional nonperfusion, or both. The aim of this s

  17. Capillary electrophoresis in a fused-silica capillary with surface roughness gradient.

    Science.gov (United States)

    Horká, Marie; Šlais, Karel; Karásek, Pavel; Růžička, Filip; Šalplachta, Jiří; Šesták, Jozef; Kahle, Vladislav; Roth, Michal

    2016-10-01

    The electro-osmotic flow, a significant factor in capillary electrophoretic separations, is very sensitive to small changes in structure and surface roughness of the inner surface of fused silica capillary. Besides a number of negative effects, the electro-osmotic flow can also have a positive effect on the separation. An example could be fused silica capillaries with homogenous surface roughness along their entire separation length as produced by etching with supercritical water. Different strains of methicillin-resistant and methicillin-susceptible Staphylococcus aureus were separated on that type of capillaries. In the present study, fused-silica capillaries with a gradient of surface roughness were prepared and their basic behavior was studied in capillary zone electrophoresis with UV-visible detection. First the influence of the electro-osmotic flow on the peak shape of a marker of electro-osmotic flow, thiourea, has been discussed. An antifungal agent, hydrophobic amphotericin B, and a protein marker, albumin, have been used as model analytes. A significant narrowing of the detected zones of the examined analytes was achieved in supercritical-water-treated capillaries as compared to the electrophoretic separation in smooth capillaries. Minimum detectable amounts of 5 ng/mL amphotericin B and 5 μg/mL albumin were reached with this method.

  18. Stochastic modeling of salt accumulation in the root zone due to capillary flux from brackish groundwater

    NARCIS (Netherlands)

    Shah, S.H.H.; Vervoort, R.W.; Suweis, S.; Guswa, A.J.; Rinaldo, A.; Zee, van der S.E.A.T.M.

    2011-01-01

    Groundwater can be a source of both water and salts in semiarid areas, and therefore, capillary pressure–induced upward water flow may cause root zone salinization. To identify which conditions result in hazardous salt concentrations in the root zone, we combined the mass balance equations for salt

  19. A Novel Polybrene/Chondroitin Sulfate C Double Coated Capillary and Its Application in Capillary Electrophoresis

    Institute of Scientific and Technical Information of China (English)

    DU,Ying-Xiang(杜迎翔); HONDA,Susumu; TAGA,Atsushi; LIU,Wen-Ying(刘文英); SUZUKI,Shigeo

    2002-01-01

    A new capillary coated by double polymer, polybrene/chondroitin sulfate C (P/CC), was developed using a simple procedure. The P/CC double coated capillary showed long lifetime,strong chemical stability and good reproducibility. It endured during more than 100 replicated analyses and was also tolerant to HCl (1 mol/L), NaOH (0.01 mol/L), CH3OH and CH3CN. The P/CC double coated capillary can be applied to basic drug analyses. The adsorption of basic drugs to the capillary wall was suppressed and the peak tailing greatly decreased. The use of the P/CC double coated capillary allowed excelent separation of the enantiomers of some basic drugs by using chondroitin sulfate C as the chiral selector, ami the peak symmetry of basic drugs was further improved under these conditions.

  20. A model and numerical method for compressible flows with capillary effects

    Science.gov (United States)

    Schmidmayer, Kevin; Petitpas, Fabien; Daniel, Eric; Favrie, Nicolas; Gavrilyuk, Sergey

    2017-04-01

    A new model for interface problems with capillary effects in compressible fluids is presented together with a specific numerical method to treat capillary flows and pressure waves propagation. This new multiphase model is in agreement with physical principles of conservation and respects the second law of thermodynamics. A new numerical method is also proposed where the global system of equations is split into several submodels. Each submodel is hyperbolic or weakly hyperbolic and can be solved with an adequate numerical method. This method is tested and validated thanks to comparisons with analytical solutions (Laplace law) and with experimental results on droplet breakup induced by a shock wave.

  1. Synthetic Capillaries to Control Microscopic Blood Flow

    Science.gov (United States)

    Sarveswaran, K.; Kurz, V.; Dong, Z.; Tanaka, T.; Penny, S.; Timp, G.

    2016-02-01

    Capillaries pervade human physiology. The mean intercapillary distance is only about 100 μm in human tissue, which indicates the extent of nutrient diffusion. In engineered tissue the lack of capillaries, along with the associated perfusion, is problematic because it leads to hypoxic stress and necrosis. However, a capillary is not easy to engineer due to its complex cytoarchitecture. Here, it is shown that it is possible to create in vitro, in about 30 min, a tubular microenvironment with an elastic modulus and porosity consistent with human tissue that functionally mimicks a bona fide capillary using “live cell lithography”(LCL) to control the type and position of cells on a composite hydrogel scaffold. Furthermore, it is established that these constructs support the forces associated with blood flow, and produce nutrient gradients similar to those measured in vivo. With LCL, capillaries can be constructed with single cell precision—no other method for tissue engineering offers such precision. Since the time required for assembly scales with the number of cells, this method is likely to be adapted first to create minimal functional units of human tissue that constitute organs, consisting of a heterogeneous population of 100–1000 cells, organized hierarchically to express a predictable function.

  2. Restructuring and aging in a capillary suspension.

    Science.gov (United States)

    Koos, Erin; Kannowade, Wolfgang; Willenbacher, Norbert

    2014-12-01

    The rheological properties of capillary suspensions, suspensions with small amounts of an added immiscible fluid, are dramatically altered with the addition of the secondary fluid. We investigate a capillary suspension to determine how the network ages and restructures at rest and under applied external shear deformation. The present work uses calcium carbonate suspended in silicone oil (11 % solids) with added water as a model system. Aging of capillary suspensions and their response to applied oscillatory shear is distinctly different from particulate gels dominated by the van der Waals forces. The suspensions dominated by the capillary force are very sensitive to oscillatory flow, with the linear viscoelastic regime ending at a deformation of only 0.1% and demonstrating power-law aging behavior. This aging persists for long times at low deformations or for shorter times with a sudden decrease in the strength at higher deformations. This aging behavior suggests that the network is able to rearrange and even rupture. This same sensitivity is not demonstrated in shear flow where very high shear rates are required to rupture the agglomerates returning the apparent viscosity of capillary suspensions to the same viscosity as for the pure vdW suspension. A transitional region is also present at intermediate water contents wherein the material response depends very strongly on the type, strength, and duration of the external forcing.

  3. Micro-injector for capillary electrophoresis.

    Science.gov (United States)

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C

    2015-08-01

    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core.

  4. Modification of narrow ablating capillaries under the influence of multiple femtosecond laser pulses

    CERN Document Server

    Gubin, K V; Trunov, V I; Pestryakov, E V

    2016-01-01

    Powerful femtosecond laser pulses that propagate through narrow ablating capillaries cause modification of capillary walls, which is studied experimentally and theoretically. At low intensities, laser-induced periodic surface structures (LIPSS) and porous coating composed of sub-micron particles appear on the walls. At higher intensities, the surface is covered by deposited droplets of the size up to 10 $\\mu$m. In both cases, the ablated material forms a solid plug that completely blocks the capillary after several hundreds or thousands of pulses. The suggested theoretical model indicates that plug formation is a universal effect. It must take place in any narrow tube subject to ablation under the action of short laser pulses.

  5. Analytical study of Joule heating effects on electrokinetic transportation in capillary electrophoresis.

    Science.gov (United States)

    Xuan, Xiangchun; Li, Dongqing

    2005-02-04

    Electric fields are often used to transport fluids (by electroosmosis) and separate charged samples (by electrophoresis) in microfluidic devices. However, there exists inevitable Joule heating when electric currents are passing through electrolyte solutions. Joule heating not only increases the fluid temperature, but also produces temperature gradients in cross-stream and axial directions. These temperature effects make fluid properties non-uniform, and hence alter the applied electric potential field and the flow field. The mass species transport is also influenced. In this paper we develop an analytical model to study Joule heating effects on the transport of heat, electricity, momentum and mass species in capillary-based electrophoresis. Close-form formulae are derived for the temperature, applied electrical potential, velocity, and pressure fields at steady state, and the transient concentration field as well. Also available are the compact formulae for the electric current and the volume flow rate through the capillary. It is shown that, due to the thermal end effect, sharp temperature drops appear close to capillary ends, where sharp rises of electric field are required to meet the current continuity. In order to satisfy the mass continuity, pressure gradients have to be induced along the capillary. The resultant curved fluid velocity profile and the increase of molecular diffusion both contribute to the dispersion of samples. However, Joule heating effects enhance the sample transport velocity, reducing the analysis time in capillary electrophoretic separations.

  6. Characteristics of ac capillary discharge produced in electrically conductive water solution

    Science.gov (United States)

    DeBaerdemaeker, F.; Simek, M.; Schmidt, J.; Leys, C.

    2007-05-01

    Basic electrical, optical and calorimetric characteristics of an ac (50 Hz) driven capillary discharge produced in a water solution were studied for initial water solution conductivity in the range 50-1000 µS cm-1. Typical current and voltage waveforms and emission intensities produced by several electronically excited species were recorded with high time resolution. The evolution of the electrical current, power and capillary resistance was inspected during positive ac half-cycle for various operational regimes. A fast relaxation of the discharge following a breakdown event was observed. Optical measurements indicate that radiative species are mostly generated during the first few hundreds of nanoseconds of plasma generation and that the average duration of plasma emission induced by a discharge pulse is of the order of a few microseconds. Results of calorimetric measurements are in good agreement with average electrical measurements and support the assumption that the discharge is a constant source of heat delivered to the liquid. Assuming that only a fraction of the heat released inside the capillary can be transported by conduction through the capillary wall and via its orifices, the processes of bubble formation, expulsion and re-filling the capillary with 'fresh' water must play a key role in maintaining a thermal balance during long-time steady-state operation of the device. Furthermore, a simplified numerical model and a first order energy deposition calculation prove the plausibility of the bubble breakdown mechanism.

  7. Novel absorption detection techniques for capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Yongjun [Iowa State Univ., Ames, IA (United States)

    1994-07-27

    Capillary electrophoresis (CE) has emerged as one of the most versatile separation methods. However, efficient separation is not sufficient unless coupled to adequate detection. The narrow inner diameter (I.D.) of the capillary column raises a big challenge to detection methods. For UV-vis absorption detection, the concentration sensitivity is only at the μM level. Most commercial CE instruments are equipped with incoherent UV-vis lamps. Low-brightness, instability and inefficient coupling of the light source with the capillary limit the further improvement of UV-vis absorption detection in CE. The goals of this research have been to show the utility of laser-based absorption detection. The approaches involve: on-column double-beam laser absorption detection and its application to the detection of small ions and proteins, and absorption detection with the bubble-shaped flow cell.

  8. Capillary rise of water in hydrophilic nanopores

    CERN Document Server

    Gruener, Simon; Wallacher, Dirk; Kityk, Andriy V; Huber, Patrick; 10.1103/PhysRevE.79.067301

    2009-01-01

    We report on the capillary rise of water in three-dimensional networks of hydrophilic silica pores with 3.5nm and 5nm mean radii, respectively (porous Vycor monoliths). We find classical square root of time Lucas-Washburn laws for the imbibition dynamics over the entire capillary rise times of up to 16h investigated. Provided we assume two preadsorbed strongly bound layers of water molecules resting at the silica walls, which corresponds to a negative velocity slip length of -0.5nm for water flow in silica nanopores, we can describe the filling process by a retained fluidity and capillarity of water in the pore center. This anticipated partitioning in two dynamic components reflects the structural-thermodynamic partitioning in strongly silica bound water layers and capillary condensed water in the pore center which is documented by sorption isotherm measurements.

  9. Capillary self-assembly of floating bodies

    Science.gov (United States)

    Jung, Sunghwan; Thompson, Paul; Bush, John

    2007-11-01

    We study the self-assembly of bodies supported on the water surface by surface tension. Attractive and repulsive capillary forces exist between menisci of, respectively, the same and opposite signs. In nature, floating objects (e.g. mosquito larvae) thus interact through capillary forces to form coherent packings on the water surface. We here present the results of an experimental investigation of such capillary pattern formation. Thin elliptical metal sheets were designed to have variable shape, flexibility and mass distribution. On the water surface, mono-, bi-, or tri-polar menisci could thus be achieved. The influence of the form of the menisci on the packings arising from the interaction of multiple floaters is explored. Biological applications are discussed.

  10. Photosensitive diazotized poly(ethylene glycol) covalent capillary coatings for analysis of proteins by capillary electrophoresis.

    Science.gov (United States)

    Yu, Bing; Chen, Xin; Cong, Hailin; Shu, Xi; Peng, Qiaohong

    2016-09-01

    A new method for the fabrication of covalently cross-linked capillary coatings of poly(ethylene glycol) (PEG) is described using diazotized PEG (diazo-PEG) as a new photosensitive coating agent. The film of diazo-PEG depends on ionic bonding and was first prepared on the inner surface of capillary by self-assembly, and ionic bonding was converted into covalent bonding after reaction of ultraviolet light with diazo groups through unique photochemical reaction. The covalently bonded coating impedance adsorption of protein on the central surface of capillary and hence the four proteins ribonuclease A, cytochrome c, bovine serum albumin, and lysosome can be baseline separated by using capillary electrophoresis (CE). The covalently cross-linked diazo-PEG capillary column coatings not only improved the CE separation performance for proteins compared to non-covalently cross-linked coatings or bare capillary but also showed a remarkable chemical solidity and repeatability. Because photosensitive diazo-PEG took the place of the highly noxious and silane moisture-sensitive coating reagents in the fabrication of covalent coating, this technique shows the advantage of being environment-friendly and having a high efficiency for CE to make the covalently bonded capillaries.

  11. Capillary Waves And Energy Coupling In Laser Materials Processing

    Science.gov (United States)

    Gasser, A.; Herziger, G.; Holtgen, B.; Kreutz, E. W.; Treusch, H. G.

    1987-09-01

    Static and dynamic measurements of the incident laser power, of the diffuse and specular reflected power have been performed in order to determine the absorption behavior of various metals and semiconductors during the interaction with powerful CO2-and Nd:YAG-laser-radiation. The absorptivity of the vapor and laser-induced plasma was probed by high-speed photography and measurements of conductivity transients as a function of intensity, composition, and pressure of the ambient atmosphere. For IIB the intensity-dependent energy coupling is governed by the generation of photon-induced plasma in the surface region in combination with the dynamics of the molten and vaporized material within the interaction zone giving in addition indication for capillary waves.

  12. Intracerebral Capillary Hemangioma: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Young; Kim, Jae Kyun; Byun, Jun Soo [Dept. of Radiology, Chung Ang University Medical Center, Chung Ang University College of Medicine, Seoul (Korea, Republic of); Park, Eon Sub [Dept. of Radiology, Chung Ang University Medical Center, Chung Ang University College of Medicine, Seoul (Korea, Republic of)

    2012-01-15

    Intracerebral capillary hemangiomas are very rare benign vascular tumors that mostly occur during infancy. We described a 69-year-old man with generalized tonic-clonic seizures who was diagnosed with an intracranial mass. Multidetector computed tomography, magnetic resonance imaging and digital subtraction angiography studies were performed for evaluation of brain, and there was a well-enhancing mass found in the right temporal lobe without a definite feeding vessel. The patient underwent surgery and the pathologic examination demonstrated marked proliferation of small vessels with a lobular pattern in the brain parenchyma, which was confirmed to be capillary hemangioma.

  13. Capillary origami and superhydrophobic membrane surfaces

    Science.gov (United States)

    Geraldi, N. R.; Ouali, F. F.; Morris, R. H.; McHale, G.; Newton, M. I.

    2013-05-01

    Capillary origami uses surface tension to fold and shape solid films and membranes into three-dimensional structures. It uses the fact that solid surfaces, no matter how hydrophobic, will tend to adhere to and wrap around the surface of a liquid. In this work, we report that a superhydrophobic coating can be created, which can completely suppress wrapping as a contacting water droplet evaporates. We also show that using a wetting azeotropic solution of allyl alcohol, which penetrates the surface features, can enhance liquid adhesion and create more powerful Capillary Origami. These findings create the possibility of selectively shaping membrane substrates.

  14. Microfluidic chip-capillary electrophoresis devices

    CERN Document Server

    Fung, Ying Sing; Du, Fuying; Guo, Wenpeng; Ma, Tongmei; Nie, Zhou; Sun, Hui; Wu, Ruige; Zhao, Wenfeng

    2015-01-01

    Capillary electrophoresis (CE) and microfluidic chip (MC) devices are relatively mature technologies, but this book demonstrates how they can be integrated into a single, revolutionary device that can provide on-site analysis of samples when laboratory services are unavailable. By introducing the combination of CE and MC technology, Microfluidic Chip-Capillary Electrophoresis Devices broadens the scope of chemical analysis, particularly in the biomedical, food, and environmental sciences.The book gives an overview of the development of MC and CE technology as well as technology that now allows

  15. TESTICULAR CAPILLARY HEMANGIOMA: DESCRIPTION OF A CASE

    Directory of Open Access Journals (Sweden)

    A. S. Markova

    2012-01-01

    Full Text Available The paper describes a clinical case of testicular capillary hemangioma in a 24-year-old man undergone a partial resection of the testis with the intraoperative morphological examination. Testicular capillary hemangioma is a rare benign tumor of a vascular origin, which can be similar to malignant testicular tumors on the clinical presentation, as well as on the imaging methods, in particular to seminoma. The intraoperative histological study can assist in avoiding organ-removing surgical interventions in diagnostically ambiguous cases if a benign testicular tumor is diagnosed.

  16. A capillary viscometer designed for the characterization of biocompatible ferrofluids

    Science.gov (United States)

    Nowak, J.; Odenbach, S.

    2016-08-01

    Suspensions of magnetic nanoparticles are receiving a growing interest in biomedical research. These ferrofluids can, e.g., be used for the treatment of cancer, making use of the drug targeting principle or using an artificially induced heating. To enable a safe application the basic properties of the ferrofluids have to be well understood, including the viscosity of the fluids if an external magnetic field is applied. It is well known that the viscosity of ferrofluids rises if a magnetic field is applied, where the rise depends on shear rate and magnetic field strength. In case of biocompatible ferrofluids such investigations proved to be rather complicated as the experimental setup should be close to the actual application to allow justified predictions of the effects which have to be expected. Thus a capillary viscometer, providing a flow situation comparable to the flow in a blood vessel, has been designed. The glass capillary is exchangeable and different inner diameters can be used. The range of the shear rates has been adapted to the range found in the human organism. The application of an external magnetic field is enabled with two different coil setups covering the ranges of magnetic field strengths required on the one hand for a theoretical understanding of particle interaction and resulting changes in viscosity and on the other hand for values necessary for a potential biomedical application. The results show that the newly designed capillary viscometer is suitable to measure the magnetoviscous effect in biocompatible ferrofluids and that the results appear to be consistent with data measured with rotational rheometry. In addition, a strong change of the flow behaviour of a biocompatible ferrofluid was proven for ranges of the shear rate and the magnetic field strength expected for a potential biomedical application.

  17. Screening for urinary amphetamine and analogs by capillary electrophoretic immunoassays and confirmation by capillary electrophoresis with on-column multiwavelength absorbance detection.

    Science.gov (United States)

    Ramseier, A; Caslavska, J; Thormann, W

    1998-11-01

    This paper characterizes competitive binding, electrokinetic capillary-based immunoassays for screening of urinary amphetamine (A) and analogs using reagents which were commercialized for a fluorescence polarization immunoassay (FPIA). After incubation of 25 microL urine with the reactants, a small aliquot of the mixture is applied onto a fused-silica capillary and unbound fluorescein-labeled tracer compounds are monitored by capillary electrophoresis with on-column laser-induced fluorescence detection. Configurations in presence and absence of micelles were investigated and found to be capable of recognizing urinary D-(+)-amphetamine at concentrations > about 80 ng/mL. Similar responses were obtained for racemic methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA). The electrokinetic immunoassay data suggest that the FPIA reagent kit includes two immunoassay systems (two antibodies and two tracer molecules), one that recognizes MA and MDMA, and one that is geared towards monitoring of A. For confirmation analysis of urinary amphetamines and ephedrines, capillary electrophoresis in a pH 9.2 buffer and multiwavelength UV detection was employed. The suitability of the electrokinetic methods for screening and confirmation is demonstrated via analysis of patient and external quality control urines.

  18. Ultrastructural changes in the optic nerve and capillary vessels during early stages of optic nerve injury

    Institute of Scientific and Technical Information of China (English)

    Xuehong Ju; Xiuyun Li; Xiaoshuang Li; Hongtao Tang; Hongguo Liu

    2008-01-01

    BACKGROUND: Capillaries are the only blood supply for optic nerves, which makes the system more vulnerable to impaired blood circulation. OBJECTIVE: To observe the ultrastructural changes in the optic nerves and capillaries in rabbits following intracanalicular segment injury to the optic nerve. DESIGN, TIME AND SETTING: Comparative, observational, pathological morphology was performed at the Department of Anatomy, Weifang Medical College from September to November 2007. MATERIALS: Models of intracanalicular segment injury to the optic nerve were induced in the right eye of thirty healthy, adult rabbits by a flee-falling metal cylinder. The H-7500 transmission electron microscope was provided by Hitachi, Japan. METHODS: All rabbits were randomly assigned into experimental (n = 25) and control (n = 5) groups. Optic nerve specimens were obtained from the experimental group at 0.5, 6, 12, 48, and 96 hours, respectively, following injury. Uitrastructural changes to the optic nerves and their capillaries were observed by electron microscopy. Optic nerve injury was not established in the control group, but optic nerve specimens were collected similarly to the experimental group. MAIN OUTCOME MEASURES: Ultrastructural changes in the injured optic nerves and their capillaries. RESULTS: Thirty rabbits were included in the final analysis. In the control group, cross-sections of the optic nerves exhibited varied thicknesses with regularly arranged fibers. The axons appeared to be smooth with condensed myelin sheaths and oval mitochondria. The microtubules and mierofilaments were clearly seen. The lumens of the capillaries were regular with densely arranged endothelial cells and visible mitochondria. In the experimental group, 30 minutes after injury to the optic nerves, swollen axons, sparse myelin sheath, disordered microtubules and microfilaments, swollen mitochondria, and a decreased number of pinocytosis vesicles and microfilaments in endothelial cells of the capillaries

  19. High-frequency capillary waves excited by oscillating microbubbles

    CERN Document Server

    Pommella, Angelo; Poulichet, Vincent; Garbin, Valeria

    2013-01-01

    This fluid dynamics video shows high-frequency capillary waves excited by the volumetric oscillations of microbubbles near a free surface. The frequency of the capillary waves is controlled by the oscillation frequency of the microbubbles, which are driven by an ultrasound field. Radial capillary waves produced by single bubbles and interference patterns generated by the superposition of capillary waves from multiple bubbles are shown.

  20. Cyclodextrin-Functionalized Monolithic Capillary Columns: Preparation and Chiral Applications.

    Science.gov (United States)

    Adly, Frady G; Antwi, Nana Yaa; Ghanem, Ashraf

    2016-02-01

    In this review, the recently reported approaches for the preparation of cyclodextrin-functionalized capillary monolithic columns are highlighted, with few applications in chiral separations using capillary liquid chromatography (CLC) and capillary electrochromatography (CEC). Chirality 28:97-109, 2016. © 2015 Wiley Periodicals, Inc.

  1. Nanoparticles as a tool in capillary electrochromatography

    OpenAIRE

    Ribeiro, Susana

    2009-01-01

    Two different types of molecularly imprinted nanoparticles against (R)-propranolol were used to separate the enantiomers of propranolol in capillary electrochromatography mode, methacrylic acid based nanoparticles and core-shell molecularly imprinted polymer nanoparticles. Partial filling technique was used to avoid interference of molecularly imprinted polymer nanoparticles in UV detection. With methacrylic acid based nanoparticles it was not possible to obtain enantiomer s...

  2. Elastic deformation due to tangential capillary forces

    NARCIS (Netherlands)

    Das, Siddhartha; Marchand, Antonin; Andreotti, Bruno; Snoeijer, Jacco H.

    2011-01-01

    A sessile liquid drop can deform the substrate on which it rests if the solid is sufficiently “soft.” In this paper we compute the detailed spatial structure of the capillary forces exerted by the drop on the solid substrate using a model based on Density Functional Theory. We show that, in addition

  3. Macroscopic theory for capillary-pressure hysteresis.

    Science.gov (United States)

    Athukorallage, Bhagya; Aulisa, Eugenio; Iyer, Ram; Zhang, Larry

    2015-03-03

    In this article, we present a theory of macroscopic contact angle hysteresis by considering the minimization of the Helmholtz free energy of a solid-liquid-gas system over a convex set, subject to a constant volume constraint. The liquid and solid surfaces in contact are assumed to adhere weakly to each other, causing the interfacial energy to be set-valued. A simple calculus of variations argument for the minimization of the Helmholtz energy leads to the Young-Laplace equation for the drop surface in contact with the gas and a variational inequality that yields contact angle hysteresis for advancing/receding flow. We also show that the Young-Laplace equation with a Dirichlet boundary condition together with the variational inequality yields a basic hysteresis operator that describes the relationship between capillary pressure and volume. We validate the theory using results from the experiment for a sessile macroscopic drop. Although the capillary effect is a complex phenomenon even for a droplet as various points along the contact line might be pinned, the capillary pressure and volume of the drop are scalar variables that encapsulate the global quasistatic energy information for the entire droplet. Studying the capillary pressure versus volume relationship greatly simplifies the understanding and modeling of the phenomenon just as scalar magnetic hysteresis graphs greatly aided the modeling of devices with magnetic materials.

  4. Capillary condensation between disks in two dimensions

    DEFF Research Database (Denmark)

    Gil, Tamir; Ipsen, John Hjorth

    1997-01-01

    Capillary condensation between two two-dimensional wetted circular substrates (disks) is studied by an effective free energy description of the wetting interface. The interfacial free-energy potential is developed on the basis of the theory for the wetting of a single disk, where interfacial capi....... The theory can be applied to the description of flocculations in two-dimensional systems of colloids....

  5. Electroviscous effects in capillary filling of nanochannels

    DEFF Research Database (Denmark)

    Mortensen, Asger; Kristensen, Anders

    2008-01-01

    We theoretically examine the widespread hypothesis of an electroviscous origin of the increase in apparent viscosity observed in recent experiments on capillary filling of nanochannels. Including Debye-layer corrections to the hydraulic resistance, we find that the apparent viscosity reaches a ma...

  6. Numerical simulations of capillary barrier field tests

    Energy Technology Data Exchange (ETDEWEB)

    Morris, C.E. [Univ. of Wollongong (Australia); Stormont, J.C. [Univ. of New Mexico, Albuquerque, NM (United States)

    1997-12-31

    Numerical simulations of two capillary barrier systems tested in the field were conducted to determine if an unsaturated flow model could accurately represent the observed results. The field data was collected from two 7-m long, 1.2-m thick capillary barriers built on a 10% grade that were being tested to investigate their ability to laterally divert water downslope. One system had a homogeneous fine layer, while the fine soil of the second barrier was layered to increase its ability to laterally divert infiltrating moisture. The barriers were subjected first to constant infiltration while minimizing evaporative losses and then were exposed to ambient conditions. The continuous infiltration period of the field tests for the two barrier systems was modelled to determine the ability of an existing code to accurately represent capillary barrier behavior embodied in these two designs. Differences between the field test and the model data were found, but in general the simulations appeared to adequately reproduce the response of the test systems. Accounting for moisture retention hysteresis in the layered system will potentially lead to more accurate modelling results and is likely to be important when developing reasonable predictions of capillary barrier behavior.

  7. Drops: The collapse of capillary jets

    Science.gov (United States)

    Cordoba, Antonio; Cordoba, Diego; Fefferman, Charles; Fontelos, Marco A.

    2002-01-01

    The appearance of fluid filaments during the evolution of a viscous fluid jet is a commonly observed phenomenon. It is shown here that the break-up of such a jet subject to capillary forces is impossible through the collapse of a uniform filament. PMID:12172005

  8. Chemical power for microscopic robots in capillaries.

    Science.gov (United States)

    Hogg, Tad; Freitas, Robert A

    2010-04-01

    The power available to microscopic robots (nanorobots) that oxidize bloodstream glucose while aggregated in circumferential rings on capillary walls is evaluated with a numerical model using axial symmetry and time-averaged release of oxygen from passing red blood cells. Robots about 1 microm in size can produce up to several tens of picowatts, in steady state, if they fully use oxygen reaching their surface from the blood plasma. Robots with pumps and tanks for onboard oxygen storage could collect oxygen to support burst power demands two to three orders of magnitude larger. We evaluate effects of oxygen depletion and local heating on surrounding tissue. These results give the power constraints when robots rely entirely on ambient available oxygen and identify aspects of the robot design significantly affecting available power. More generally, our numerical model provides an approach to evaluating robot design choices for nanomedicine treatments in and near capillaries. The power available to microscopic robots (nanorobots) that oxidize bloodstream glucose while aggregated in circumferential rings on capillary walls was evaluated in this study. The presented numerical model provides an approach to evaluating robot design choices for nanomedicine treatments in and near capillaries. Copyright 2010. Published by Elsevier Inc.

  9. Shift dynamics of capillary self-alignment

    NARCIS (Netherlands)

    Arutinov, G.; Mastrangeli, M.; Smits, E.C.P.; Heck, G.V.; Schoo, H.F.M.; Toonder, J.J.M. den; Dietzel, A.H.

    2014-01-01

    This paper describes the dynamics of capillary self-alignment of components with initial shift offsets from matching receptor sites. The analysis of the full uniaxial self-alignment dynamics of foil-based mesoscopic dies from pre-alignment to final settling evidenced three distinct, sequential regim

  10. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida;

    2014-01-01

    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  11. In-capillary detection of fast antibody-peptide binding using fluorescence coupled capillary electrophoresis.

    Science.gov (United States)

    Qin, Yuqin; Qiu, Lin; Qin, Haifang; Ding, Shumin; Liu, Li; Teng, Yiwan; Chen, Yao; Wang, Cheli; Li, Jinchen; Wang, Jianhao; Jiang, Pengju

    2016-01-01

    Herein, we report a technique for detecting the fast binding of antibody-peptide inside a capillary. Anti-HA was mixed and interacted with FAM-labeled HA tag (FAM-E4 ) inside the capillary. Fluorescence coupled capillary electrophoresis (CE-FL) was employed to measure and record the binding process. The efficiency of the antibody-peptide binding on in-capillary assays was found to be affected by the molar ratio. Furthermore, the stability of anti-HA-FAM-E4 complex was investigated as well. The results indicated that E4 YPYDVPDYA (E4) or TAMRA-E4 YPYDVPDYA (TAMRA-E4) had the same binding priorities with anti-HA. The addition of excess E4 or TAMRA-E4 could lead to partial dissociation of the complex and take a two-step mechanism including dissociation and association. This method can be applied to detect a wide range of biomolecular interactions.

  12. Preparation approaches of the coated capillaries with liposomes in capillary electrophoresis.

    Science.gov (United States)

    Mei, Jie; Tian, Yan-Ping; He, Wen; Xiao, Yu-Xiu; Wei, Juan; Feng, Yu-Qi

    2010-10-29

    The use of liposomes as coating materials in capillary electrophoresis has recently emerged as an important and popular research area. There are three preparation methods that are commonly used for coating capillaries with liposomes, namely physical adsorption, avidin-biotin binding and covalent coupling. Herein, the three different coating methods were compared, and the liposome-coated capillaries prepared by these methods were evaluated by studying systematically their EOF characterization and performance (repeatability, reproducibility and lifetime). The amount of immobilized phospholipids and the interactions between liposome or phospholipid membrane and neutral compounds for the liposome-coated capillaries prepared by these methods were also investigated in detail. Finally, the merits and disadvantages for each coating method were reviewed.

  13. Elasto-capillary windlass: from spider web to synthetic actuators

    Science.gov (United States)

    Elettro, Hervé; Antkowiak, Arnaud; Neukirch, Sébastien; Vollrath, Fritz; Institut D'Alembert Team; Oxford Silk Group Team

    2015-03-01

    Spiders' threads display a wide range of materials properties. The glue-covered araneid capture silk is unique among all silks because it is self tensing and remains taut even if compressed, allowing both thread and web to be in a constant state of tension. Here we demonstrate how this effect is achieved by unraveling the physics allowing the nanolitre glue droplets straddling the silk thread to induce buckling, coiling and spooling of the core filaments. Our model examines this windlass activation as a structural phase transition, which shows that fibre spooling results from the interplay between elasticity and capillarity. Fibre size is the key as such a capillary windlass requires micrometer-sized fibres in order to function. Our synthetic capillary windlasses point towards design principles for new bioinspired synthetic actuators. The present work was supported by ANR Grant ANR-09-JCJC-0022-01, ``La Ville de Paris - Programme Emergence,'' Royal Society International Exchanges Scheme 2013/R1 Grant IE130506, and the PEPS PTI program from CNRS.

  14. Recent advances of ionic liquids and polymeric ionic liquids in capillary electrophoresis and capillary electrochromatography.

    Science.gov (United States)

    Tang, Sheng; Liu, Shujuan; Guo, Yong; Liu, Xia; Jiang, Shengxiang

    2014-08-29

    Ionic liquids (ILs) and polymeric ionic liquids (PILs) with unique and fascinating properties have drawn considerable interest for their use in separation science, especially in chromatographic techniques. In this article, significant contributions of ILs and PILs in the improvement of capillary electrophoresis and capillary electrochromatography are described, and a specific overview of the most relevant examples of their applications in the last five years is also given. Accordingly, some general conclusions and future perspectives in these areas are discussed.

  15. Evaluation of migration behaviour of therapeutic peptide hormones in capillary electrophoresis using polybrene-coated capillaries.

    Science.gov (United States)

    Aptisa, Ghiulendan; Benavente, Fernando; Sanz-Nebot, Victoria; Chirila, Elisabeta; Barbosa, José

    2010-02-01

    Modelling electrophoretic mobility as a function of pH can be simultaneously used for determination of ionization constants and for rapid selection of the optimum pH for separation of mixtures of the modelled compounds. In this work, equations describing the effect of pH on electrophoretic behaviour were used to investigate migration of a series of polyprotic amphoteric peptide hormones between pH 2 and 12 in polybrene-coated capillaries. Polybrene (hexadimethrin bromide) is a polymer composed of quaternary amines that is strongly adsorbed by the fused-silica inner surface, preventing undesired interactions between the peptides and the inner capillary wall. In polybrene-coated capillaries the separation voltage must be reversed, because of the anodic electroosmotic flow promoted by the polycationic polymer attached to the inner capillary wall. The possibility of using polybrene-coated capillaries for determination of accurate ionization constants has been evaluated and the optimum pH for separation of a mixture of the peptide hormones studied has been selected. Advantages and disadvantages of using bare fused-silica and polybrene-coated capillaries for these purposes are discussed.

  16. A complete soil hydraulic model accounting for capillary and adsorptive water retention, capillary and film conductivity, and hysteresis

    NARCIS (Netherlands)

    Sakai, Masaru; Van Genuchten, Martinus Th; Alazba, A. A.; Setiawan, Budi Indra; Minasny, Budiman

    2015-01-01

    A soil hydraulic model that considers capillary hysteretic and adsorptive water retention as well as capillary and film conductivity covering the complete soil moisture range is presented. The model was obtained by incorporating the capillary hysteresis model of Parker and Lenhard into the hydraulic

  17. Capillary pressure and saturation relations for supercritical CO2 and brine in sand: High-pressure Pc(Sw) controller/meter measurements and capillary scaling predictions

    Science.gov (United States)

    Tokunaga, Tetsu K.; Wan, Jiamin; Jung, Jong-Won; Kim, Tae Wook; Kim, Yongman; Dong, Wenming

    2013-08-01

    In geologic carbon sequestration, reliable predictions of CO2 storage require understanding the capillary behavior of supercritical (sc) CO2. Given the limited availability of measurements of the capillary pressure (Pc) dependence on water saturation (Sw) with scCO2 as the displacing fluid, simulations of CO2 sequestration commonly rely on modifying more familiar air/H2O and oil/H2O Pc(Sw) relations, adjusted to account for differences in interfacial tensions. In order to test such capillary scaling-based predictions, we developed a high-pressure Pc(Sw) controller/meter, allowing accurate Pc and Sw measurements. Drainage and imbibition processes were measured on quartz sand with scCO2-brine at pressures of 8.5 and 12.0 MPa (45°C), and air-brine at 21°C and 0.1 MPa. Drainage and rewetting at intermediate Sw levels shifted to Pc values that were from 30% to 90% lower than predicted based on interfacial tension changes. Augmenting interfacial tension-based predictions with differences in independently measured contact angles from different sources led to more similar scaled Pc(Sw) relations but still did not converge onto universal drainage and imbibition curves. Equilibrium capillary trapping of the nonwetting phases was determined for Pc = 0 during rewetting. The capillary-trapped volumes for scCO2 were significantly greater than for air. Given that the experiments were all conducted on a system with well-defined pore geometry (homogeneous sand), and that scCO2-brine interfacial tensions are fairly well constrained, we conclude that the observed deviations from scaling predictions resulted from scCO2-induced decreased wettability. Wettability alteration by scCO2 makes predicting hydraulic behavior more challenging than for less reactive fluids.

  18. A liquid core waveguide fluorescence detector for multicapillary electrophoresis applied to DNA sequencing in a 91-capillary array.

    Science.gov (United States)

    Hanning, A; Westberg, J; Roeraade, J

    2000-09-01

    A new laser-induced fluorescence (LIF) detector for multicapillary electrophoresis is presented. The detection principle is based on waveguiding of the emitted fluorescence from the point of illumination to the capillary ends by total internal reflection (TIR) and imaging of the capillary ends. The capillaries themselves thus act as liquid core waveguides (LCWs). At the illumination point, the capillaries are arranged in a planar array, which allows clean and efficient illumination with a line-focused laser beam. The capillary ends are rearranged into a small, densely packed two-dimensional array, which is imaged end-on with high light collection efficiency and excellent image quality. Wavelength dispersion is obtained with a single prism. Intercapillary optical crosstalk is less than 0.5%, and rejection of stray light is very efficient. The detector is applied to four-color DNA sequencing by gel electrophoresis in a 91-capillary array, with simple fluorescein and rhodamine dyes as fluorophores. Since the imaged two-dimensional array is so compact, the detector has a high potential for very large-scale multiplexing.

  19. Gold nanoparticles deposited capillaries for in-capillary microextraction capillary zone electrophoresis of monohydroxy-polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Wang, Huiyong; Knobel, Gaston; Wilson, Walter B; Calimag-Williams, Korina; Campiglia, Andres D

    2011-03-01

    This article presents the first application of gold nanoparticles deposited capillaries as pre-concentration devices for in-capillary microextraction CZE and their use for the analysis of monohydroxy-polycyclic aromatic hydrocarbons in synthetic urine samples. The successful separation of 1-hydroxypyrene, 9-hydroxyphenanthrene, 3-hydroxybenzo[a]pyrene (3-OHbap), 4-hydroxybenzo[a]pyrene and 5-hydroxybenzo[a]pyrene under a single set of electrophoretic conditions is demonstrated as well as the feasibility to obtain competitive ultraviolet absorption LOD with commercial instrumentation. Enrichment factors ranging from 87 (9-OHphe) to 100 (3-OHbap) made it possible to obtain LOD ranging from 9 ng/mL (9-OHphe and 3-OHbap) to 14 ng/mL (4-hydroxybenzo[a]pyrene).

  20. Capillary Interactions between a Probe Tip and a Nanoparticle

    Institute of Scientific and Technical Information of China (English)

    SUN Li-Ning; WANG Le-Feng; RONG Wei-Bin

    2008-01-01

    To understand capillary interactions between probe tips and nanoparticles under ambient conditions,a theoretical model of capillary forces between them is developed based on the geometric relations. It is found that the contribution of surface tension force to the total capillary force attains to similar order of magnitude as the capillary pressure force in many cases.It is also shown that the tip shape and the radial distance of the meniscus have great influence on the capillary force.The capillary force decreases with the increasing separation distances,and the variance of the contact angles may change the magnitudes of capillary forces several times at large radial distances.The applicability of the symmetric meniscus approximation is discussed.

  1. High Throughput Sample Preparation and Analysis for DNA Sequencing, PCR and Combinatorial Screening of Catalysis Based on Capillary Array Technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yonghua [Iowa State Univ., Ames, IA (United States)

    2000-01-01

    Sample preparation has been one of the major bottlenecks for many high throughput analyses. The purpose of this research was to develop new sample preparation and integration approach for DNA sequencing, PCR based DNA analysis and combinatorial screening of homogeneous catalysis based on multiplexed capillary electrophoresis with laser induced fluorescence or imaging UV absorption detection. The author first introduced a method to integrate the front-end tasks to DNA capillary-array sequencers. protocols for directly sequencing the plasmids from a single bacterial colony in fused-silica capillaries were developed. After the colony was picked, lysis was accomplished in situ in the plastic sample tube using either a thermocycler or heating block. Upon heating, the plasmids were released while chromsomal DNA and membrane proteins were denatured and precipitated to the bottom of the tube. After adding enzyme and Sanger reagents, the resulting solution was aspirated into the reaction capillaries by a syringe pump, and cycle sequencing was initiated. No deleterious effect upon the reaction efficiency, the on-line purification system, or the capillary electrophoresis separation was observed, even though the crude lysate was used as the template. Multiplexed on-line DNA sequencing data from 8 parallel channels allowed base calling up to 620 bp with an accuracy of 98%. The entire system can be automatically regenerated for repeated operation. For PCR based DNA analysis, they demonstrated that capillary electrophoresis with UV detection can be used for DNA analysis starting from clinical sample without purification. After PCR reaction using cheek cell, blood or HIV-1 gag DNA, the reaction mixtures was injected into the capillary either on-line or off-line by base stacking. The protocol was also applied to capillary array electrophoresis. The use of cheaper detection, and the elimination of purification of DNA sample before or after PCR reaction, will make this approach an

  2. High Throughput Sample Preparation and Analysis for DNA Sequencing, PCR and Combinatorial Screening of Catalysis Based on Capillary Array Technique

    Energy Technology Data Exchange (ETDEWEB)

    Yonghua Zhang

    2002-05-27

    Sample preparation has been one of the major bottlenecks for many high throughput analyses. The purpose of this research was to develop new sample preparation and integration approach for DNA sequencing, PCR based DNA analysis and combinatorial screening of homogeneous catalysis based on multiplexed capillary electrophoresis with laser induced fluorescence or imaging UV absorption detection. The author first introduced a method to integrate the front-end tasks to DNA capillary-array sequencers. protocols for directly sequencing the plasmids from a single bacterial colony in fused-silica capillaries were developed. After the colony was picked, lysis was accomplished in situ in the plastic sample tube using either a thermocycler or heating block. Upon heating, the plasmids were released while chromsomal DNA and membrane proteins were denatured and precipitated to the bottom of the tube. After adding enzyme and Sanger reagents, the resulting solution was aspirated into the reaction capillaries by a syringe pump, and cycle sequencing was initiated. No deleterious effect upon the reaction efficiency, the on-line purification system, or the capillary electrophoresis separation was observed, even though the crude lysate was used as the template. Multiplexed on-line DNA sequencing data from 8 parallel channels allowed base calling up to 620 bp with an accuracy of 98%. The entire system can be automatically regenerated for repeated operation. For PCR based DNA analysis, they demonstrated that capillary electrophoresis with UV detection can be used for DNA analysis starting from clinical sample without purification. After PCR reaction using cheek cell, blood or HIV-1 gag DNA, the reaction mixtures was injected into the capillary either on-line or off-line by base stacking. The protocol was also applied to capillary array electrophoresis. The use of cheaper detection, and the elimination of purification of DNA sample before or after PCR reaction, will make this approach an

  3. Elasto-capillary torsion at a liquid interface

    Science.gov (United States)

    Oratis, Alexandros; Farmer, Timothy; Bird, James

    2016-11-01

    When a liquid drop wets a solid, the droplet typically spreads over the solid. By contrast, for sufficiently compliant solids, the solid can instead spread around the drop. This wrapping phenomenon has been exploited to assemble 3-dimensional structures from 2-dimensional sheets, a process often referred to as capillary origami. Although existing studies of this self-assembly have demonstrated bending and folding, methods of inducing spontaneous twisting by means of capillarity are less clear. Here we demonstrate that spontaneous twist can be initiated in a compliant solid through a combination of surface chemistry and capillarity. Experimentally, we measure the angle of twist on a surface with binary patterns of surface wettability as we vary the solid's geometric and material properties. We develop a scaling law to relate this angle of twist to the elastic and interfacial properties, which compares well with our experimental results.

  4. Capillary states of granular materials in the funicular state

    Science.gov (United States)

    Delenne, Jean-Yves; Richefeu, Vincent; Radjai, Farhang

    2013-06-01

    Using a multi-phase lattice Boltzmann model, we investigate the capillary states of a 2D granular packing gradually saturated by condensation from a homogeneously injected vapor phase. The internal stresses induced by surface tension and Laplace pressure are directly calculated from the forces acting on the grains with increasing amount of liquid. The evolution of cohesive strength with the amount of liquid reveals four different states reflecting the connectivity of the liquid phase and local grain environments. It increases in the pendular state, characterized by binary liquid bridges holding the grains together, and within the funicular state with an increasing number of liquid clusters connected to several grains. Beyond 40% of saturation, the cohesive strength falls off due to a decreasing Laplace pressure of liquid clusters.

  5. Pore alterations of the endothelial lining of rat fenestrated intestinal capillaries exposed to acute stress.

    Science.gov (United States)

    Aosa, Taishi; Chiba, Seiichi; Kitamura, Hirokazu; Ina, Keisuke; Tatsukawa, Shuji; Moriwaki, Chinatsu; Wei, Huixing; Gotoh, Koro; Masaki, Takayuki; Kakuma, Tetsuya; Shibata, Hirotaka; Fujikura, Yoshihisa

    2016-07-01

    Stress-induced inflammatory responses in the portal system are characterized by elevations in serum concentrations of interleukin-6 (IL-6) and endotoxins such as lipopolysaccharides (LPS). LPS translocation from the intestinal to the capillary lumen occurs via LPS endocytosis by the capillary endothelium. Because the capillary endothelium of the small intestinal submucosa is fenestrated, we determined the role of pore modifications within the fenestrated endothelium in relaying inflammatory stress responses in the portal vein. We evaluated changes in the diameter and density of endothelial pores of the lamina propria of intestinal villi induced by continuous light (CL) exposure for 48 h and the correlation between these changes and serum IL-6 concentration in the portal vein in a rat model. We found significant increases in both the pore diameter and density, accompanied by a significant increase in portal IL-6 concentration; these changes were significantly attenuated by pretreatment with propranolol, a beta adrenergic receptor antagonist. In contrast, intravenous noradrenaline administration mimicked CL-induced modifications of the diameter and density of pores and the elevation of portal vein IL-6 concentration. These findings suggested that stress-induced inflammatory responses in the portal system may be a part of the modifications of the endothelial pores triggered by sympathetic activation.

  6. Capillary flow through heat-pipe wicks

    Science.gov (United States)

    Eninger, J. E.

    1975-01-01

    Theoretical expressions are obtained for the capillary-pressure limit and permeability of a fibrous wick in terms of the porosity and fiber diameter. Hysteresis in capillary pressure is included through the introduction of an empirical hysteresis constant. A partial-saturation model based on the statistical distribution of local porosity requires an additional empirical constant, the standard deviation. The theory is compared to results of a beta-ray absorption experiment that measured the liquid content of a partially saturated wick and to results of permeability measurements on partially and fully saturated wicks. A simple wick-weighing experiment is described that yields values for the empirical hysteresis constant and the standard deviation. Theoretical results are used to design an optimum wick.

  7. Chemical Power for Microscopic Robots in Capillaries

    CERN Document Server

    Hogg, Tad

    2009-01-01

    The power available to microscopic robots (nanorobots) that oxidize bloodstream glucose while aggregated in circumferential rings on capillary walls is evaluated with a numerical model using axial symmetry and time-averaged release of oxygen from passing red blood cells. Robots about one micron in size can produce up to several tens of picowatts, in steady-state, if they fully use oxygen reaching their surface from the blood plasma. Robots with pumps and tanks for onboard oxygen storage could collect oxygen to support burst power demands two to three orders of magnitude larger. We evaluate effects of oxygen depletion and local heating on surrounding tissue. These results give the power constraints when robots rely entirely on ambient available oxygen and identify aspects of the robot design significantly affecting available power. More generally, our numerical model provides an approach to evaluating robot design choices for nanomedicine treatments in and near capillaries.

  8. Space-Time Resolved Capillary Wave Turbulence

    CERN Document Server

    Berhanu, Michael

    2012-01-01

    We report experiments on the full space and time resolved statistics of capillary wave turbulence at the air-water interface. The three-dimensional shape of the free interface is measured as a function of time by using the optical method of Diffusing Light Photography associated with a fast camera. Linear and nonlinear dispersion relations are extracted from the spatio-temporal power spectrum of wave amplitude. When wave turbulence regime is reached, we observe power-law spectra both in frequency and in wave number, whose exponents are found in agreement with the predictions of capillary wave turbulence theory. Finally, the temporal dynamics of the spatial energy spectrum highlights the occurrence of stochastic bursts transferring wave energy through the spatial scales.

  9. The geometry and wetting of capillary folding

    CERN Document Server

    Péraud, Jean-Philippe

    2014-01-01

    Capillary forces are involved in a variety of natural phenomena, ranging from droplet breakup to the physics of clouds. The forces from surface tension can also be exploited in industrial application provided the length scales involved are small enough. Recent experimental investigations showed how to take advantage of capillarity to fold planar structures into three-dimensional configurations by selectively melting polymeric hinges joining otherwise rigid shapes. In this paper we use theoretical calculations to quantify the role of geometry and fluid wetting on the final folded state. Considering folding in two and three dimensions, studying both hydrophilic and hydrophobic situations with possible contact angle hysteresis, and addressing the shapes to be folded to be successively infinite, finite, curved, kinked, elastic, we are able to derive an overview of the geometrical parameter space available for capillary folding.

  10. Transversally periodic solitary gravity–capillary waves

    Science.gov (United States)

    Milewski, Paul A.; Wang, Zhan

    2014-01-01

    When both gravity and surface tension effects are present, surface solitary water waves are known to exist in both two- and three-dimensional infinitely deep fluids. We describe here solutions bridging these two cases: travelling waves which are localized in the propagation direction and periodic in the transverse direction. These transversally periodic gravity–capillary solitary waves are found to be of either elevation or depression type, tend to plane waves below a critical transverse period and tend to solitary lumps as the transverse period tends to infinity. The waves are found numerically in a Hamiltonian system for water waves simplified by a cubic truncation of the Dirichlet-to-Neumann operator. This approximation has been proved to be very accurate for both two- and three-dimensional computations of fully localized gravity–capillary solitary waves. The stability properties of these waves are then investigated via the time evolution of perturbed wave profiles. PMID:24399922

  11. Modeling Microscopic Chemical Sensors in Capillaries

    CERN Document Server

    Hogg, Tad

    2008-01-01

    Nanotechnology-based microscopic robots could provide accurate in vivo measurement of chemicals in the bloodstream for detailed biological research and as an aid to medical treatment. Quantitative performance estimates of such devices require models of how chemicals in the blood diffuse to the devices. This paper models microscopic robots and red blood cells (erythrocytes) in capillaries using realistic distorted cell shapes. The models evaluate two sensing scenarios: robots moving with the cells past a chemical source on the vessel wall, and robots attached to the wall for longer-term chemical monitoring. Using axial symmetric geometry with realistic flow speeds and diffusion coefficients, we compare detection performance with a simpler model that does not include the cells. The average chemical absorption is quantitatively similar in both models, indicating the simpler model is an adequate design guide to sensor performance in capillaries. However, determining the variation in forces and absorption as cells...

  12. Capillary deposition of advected floating particles

    Science.gov (United States)

    Dressaire, Emilie; Debaisieux, Aymeric; Gregori, Federico

    2016-11-01

    The deposition and aggregation of particles flowing through a confined environment can dramatically hinder the transport of suspensions. Yet, the mechanisms responsible for the deposition of particles in shear flow are not fully understood. Here, we use an experimental model system in which floating particles are advected on the surface of a water channel and deposited on fixed obstacles through attractive capillary effects. By varying the flow rate of the liquid, the wetting properties and size of the particles and obstacles, we can tune the magnitude of the capillary and hydrodynamic forces that determine the probability of deposition and the equilibrium position on the substrate. We show that arrays of obstacles can be designed to efficiently capture the floating particles advected by the flow.

  13. Capillary droplets on Leidenfrost micro-ratchets

    CERN Document Server

    Marin, Alvaro G; Römer, Gertwillem R B E; Pathiraj, B; Veld, Albertus Huis in 't; Lohse, Detlef

    2012-01-01

    Leidenfrost ratchets are structures with the ability of transporting liquid droplets when heated over the critical Leidenfrost temperature. Once this temperature is reached, the droplet levitates over the surface and moves in the direction marked by the slope of the ratchet at terminal velocities around 10 cm/s. Here we provide new experiments with micron-sized ratchets, which have been produced with picosecond pulse laser ablation. In the following work, we use a simple method to measure the thrust driving droplets of capillary size over the micro-ratchets. The mechanism responsible for the force acting on the drop on superheated ratchets has been recently under debate. We extend the recently proposed 'viscous mechanism' proposed by Dupeaux et al. [Europhys. Lett., 96, 58001 (2011)] to capillary droplets and find good agreement with our measurements.

  14. Capillary fluid loop developments in Astrium

    Energy Technology Data Exchange (ETDEWEB)

    Figus, C.; Ounougha, L.; Bonzom, P. [Astrium SAS, Toulouse (France); Supper, W. [ESA/ESTEC, Noordwijk (Netherlands); Puillet, C. [CNES, Toulouse (France)

    2003-06-01

    Over the past decade, Astrium has been involved in the development of capillary pumped fluid loops. In the frame of the French technological demonstrator spacecraft called STENTOR, Astrium has gained experience on capillary fluid loop design and manufacturing. After the STENTOR cylindrical evaporator type was successfully tested and qualified, Astrium has developed miniaturised fluid loops for thermal dissipation of electronic devices. For such applications, the use of a flat shape evaporator is very promising, limiting the volume and the mass of the thermal hardware. Both technologies have been submitted to a comprehensive one-g test program and will be flight-tested in the near future. Through a comparative of the reached performances, some main advantages and drawbacks of each design are listed and a definition of what should be the next generation of Astrium fluid loops is given. (author)

  15. [Congenital pulmonary capillary hemangiomatosis in a newborn].

    Science.gov (United States)

    Sposito Cavallo, Sandra L; Macias Sobrino, Luciano A; Marenco Altamar, Luifer J; Mejía Alquichire, Andrés F

    2017-02-01

    Pulmonary capillary hemangiomatosis is a rare entity characterized by the proliferation of capillaries into alveolar walls, interlobular septa, pleura and pulmonary interstitium, without malignant characteristics, with almost constant association with pulmonary hypertension. Until now two cases of congenital presentation have been reported in the literature. This is the third case in a newborn; he has not followed the usual pattern associated with pulmonary hypertension as occurs in most patients with this pathology; the highest incidence is among 20-40 years old. We report a preterm newborn patient of 36 weeks of gestation with progressive respiratory distress requiring mechanical ventilation by constant desaturation during his clinical evolution without clinical, radiological or ultrasonographic signs of pulmonary hypertension.

  16. Capillary condensation for fluids in spherical cavities

    OpenAIRE

    Urrutia, Ignacio; Szybisz, Leszek

    2005-01-01

    The capillary condensation for fluids into spherical nano-cavities is analyzed within the frame of two theoretical approaches. One description is based on a widely used simplified version of the droplet model formulated for studying atomic nuclei. The other, is a more elaborated calculation performed by applying a density functional theory. The agreement between both models is examined and it is shown that a small correction to the simple fluid model improves the predictions. A connection to ...

  17. Novel cationic polyelectrolyte coatings for capillary electrophoresis.

    Science.gov (United States)

    Duša, Filip; Witos, Joanna; Karjalainen, Erno; Viitala, Tapani; Tenhu, Heikki; Wiedmer, Susanne K

    2016-01-01

    The use of bare fused silica capillary in CE can sometimes be inconvenient due to undesirable effects including adsorption of sample or instability of the EOF. This can often be avoided by coating the inner surface of the capillary. In this work, we present and characterize two novel polyelectrolyte coatings (PECs) poly(2-(methacryloyloxy)ethyl trimethylammonium iodide) (PMOTAI) and poly(3-methyl-1-(4-vinylbenzyl)-imidazolium chloride) (PIL-1) for CE. The coated capillaries were studied using a series of aqueous buffers of varying pH, ionic strength, and composition. Our results show that the investigated polyelectrolytes are usable as semi-permanent (physically adsorbed) coatings with at least five runs stability before a short coating regeneration is necessary. Both PECs showed a considerably decreased stability at pH 11.0. The EOF was higher using Good's buffers than with sodium phosphate buffer at the same pH and ionic strength. The thickness of the PEC layers studied by quartz crystal microbalance was 0.83 and 0.52 nm for PMOTAI and PIL-1, respectively. The hydrophobicity of the PEC layers was determined by analysis of a homologous series of alkyl benzoates and expressed as the distribution constants. Our result demonstrates that both PECs had comparable hydrophobicity, which enabled separation of compounds with log Po/w > 2. The ability to separate cationic drugs was shown with β-blockers, compounds often misused in doping. Both coatings were also able to separate hydrolysis products of the ionic liquid 1,5-diazabicyclo[4.3.0]non-5-ene acetate at highly acidic conditions, where bare fused silica capillaries failed to accomplish the separation.

  18. Capillary floating and the billiard ball problem

    OpenAIRE

    Gutkin, Eugene

    2010-01-01

    We establish a connection between capillary floating in neutral equilibrium and the billiard ball problem. This allows us to reduce the question of floating in neutral equilibrium at any orientation with a prescribed contact angle for infinite homogeneous cylinders to a question about billiard caustics for their orthogonal cross-sections. We solve the billiard problem. As an application, we characterize the possible contact angles and exhibit an infinite family of real analytic non-round cyli...

  19. Capillary Electrophoresis in the Presence of Fosfomycin

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Fosfomyein, a sodim salt of cis-(3-methyloxiranyl) phosphonic acid, was used as electrolyte in binary methanol-water media for capillary electrophoresis. The variety of electroosmotic flow with pH*,methanol concentration and ionic strength was investigated. The migration behavior of nine bases was examined under various conditions, and the separation of thymine, cytosine, 5-flurouracil, 4,6-diamino-pyrimidine, purine was accomplished.

  20. Bacterial surface layer proteins as a novel capillary coating material for capillary electrophoretic separations

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Gordaliza, Estefanía, E-mail: emorenog@ucm.es [Division of Analytical Biosciences, Leiden Academic Centre for Drug Research, Universiteit Leiden, Einsteinweg 55, 2300, RA, Leiden (Netherlands); Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Avda. Complutense s/n, 28040, Madrid (Spain); Stigter, Edwin C.A. [Division of Analytical Biosciences, Leiden Academic Centre for Drug Research, Universiteit Leiden, Einsteinweg 55, 2300, RA, Leiden (Netherlands); Department of Molecular Cancer Research, Universitair Medisch Centrum Utrecht, Wilhelmina Kinder Ziekenhuis, Lundlaan 6, 3584, EA Utrecht (Netherlands); Lindenburg, Petrus W.; Hankemeier, Thomas [Division of Analytical Biosciences, Leiden Academic Centre for Drug Research, Universiteit Leiden, Einsteinweg 55, 2300, RA, Leiden (Netherlands)

    2016-06-07

    A novel concept for stable coating in capillary electrophoresis, based on recrystallization of surface layer proteins on hydrophobized fused silica capillaries, was demonstrated. Surface layer protein A (SlpA) from Lactobacillus acidophilus bacteria was extracted, purified and used for coating pre-silanized glass substrates presenting different surface wettabilities (either hydrophobic or hydrophilic). Contact angle determination on SlpA-coated hydrophobic silica slides showed that the surfaces turned to hydrophilic after coating (53 ± 5°), due to a protein monolayer formation by protein-surface hydrophobic interactions. Visualization by atomic force microscopy demonstrated the presence of a SlpA layer on methylated silica slides displaying a surface roughness of 0.44 ± 0.02 nm. Additionally, a protein layer was visualized by fluorescence microscopy in methylated silica capillaries coated with SlpA and fluorescein isothiocyanate-labeled. The SlpA-coating showed an outstanding stability, even after treatment with 20 mM NaOH (pH 12.3). The electroosmotic flow in coated capillaries showed a partial suppression at pH 7.50 (3.8 ± 0.5 10{sup −9} m{sup 2} V{sup −1} s{sup −1}) when compared with unmodified fused silica (5.9 ± 0.1 10{sup −8} m{sup 2} V{sup −1} s{sup −1}). To demonstrate the potential of this novel coating, the SlpA-coated capillaries were applied for the first time for electrophoretic separation, and proved to be very suitable for the isotachophoretic separation of lipoproteins in human serum. The separations showed a high degree of repeatability (absolute migration times with 1.1–1.8% coefficient-of-variation (CV) within a day) and 2–3% CV inter-capillary reproducibility. The capillaries were stable for more than 100 runs at pH 9.40, and showed to be an exceptional alternative for challenging electrophoretic separations at long-term use. - Highlights: • New coating using recrystallized surface-layer proteins on

  1. Elasto-capillary collapse of floating structures - Non-linear response of elastic structures under capillary forces

    CERN Document Server

    Adami, N; Roman, B; Bico, J; Caps, H

    2013-01-01

    Flexible rings and rectangle structures floating at the surface of water are prone to deflect under the action of surface pressure induced by the addition of surfactant molecules on the bath. While the frames of rectangles bend inward or outward for any surface pressure difference, circles are only deformed by compression beyond a critical buckling load. However, compressed frames also undergo a secondary buckling instability leading to a rhoboidal shape. Following the pioneering works of \\cite{Hu} and \\cite{Zell}, we describe both experimentally and theoretically the different elasto-capillary deflection and buckling modes as a function of the material parameters. In particular we show how this original fluid structure interaction may be used to probe the adsorption of surfactant molecules at liquid interfaces.

  2. Improving the sensitivity in chiral capillary electrophoresis.

    Science.gov (United States)

    Sánchez-López, Elena; Marina, María Luisa; Crego, Antonio L

    2016-01-01

    CE is known for being one of the most powerful analytical techniques when performing enantioseparations due to its numerous advantages such as excellent separation efficiency and extremely low solvents and reagents consumption, all of them derived from the capillary small dimensions. Moreover, it is worth highlighting that unlike in chromatographic techniques, in CE the chiral selector is generally within the separation medium instead of being attached to the separation column which makes the method optimization a more versatile task. Despite its numerous advantages, when using UV-Vis detection, CE lacks of sensitivity detection due to its short optical path length derived from the narrow separation capillary. This issue can be overcome by means of different approaches, either by sample treatment procedures or by in-capillary preconcentration techniques or even by employing detection systems more sensitive than UV-Vis, such as LIF or MS. The present review assembles the latest contributions regarding improvements of sensitivity in chiral CE published from June 2013 until May 2015, which follows the works included in a previous review reported by Sánchez-Hernández et al. [Electrophoresis 2014, 35, 12-27].

  3. Highly conductive, printable pastes from capillary suspensions

    Science.gov (United States)

    Schneider, Monica; Koos, Erin; Willenbacher, Norbert

    2016-08-01

    We have used the capillary suspension phenomenon to design conductive pastes for printed electronic applications, such as front side metallization of solar cells, without non-volatile, organic additives that often deteriorate electrical properties. Adding a small amount of a second, immiscible fluid to a suspension creates a network of liquid bridges between the particles. This capillary force-controlled microstructure allows for tuning the flow behavior in a wide range. Yield stress and low-shear viscosity can be adjusted such that long-term stability is provided by inhibiting sedimentation, and, even more importantly, narrow line widths and high aspect ratios are accessible. These ternary mixtures, called capillary suspensions, exhibit a strong degree of shear thinning that allows for conventional coating or printing equipment to be used. Finally, the secondary fluid, beneficial for stability and processing of the wet paste, completely evaporates during drying and sintering. Thus, we obtained high purity silver and nickel layers with a conductivity two times greater than could be obtained with state-of-the-art, commercial materials. This revolutionary concept can be easily applied to other systems using inorganic or even organic conductive particles and represents a fundamental paradigm change to the formulation of pastes for printed electronics.

  4. Capillary condensation as a morphological transition.

    Science.gov (United States)

    Kornev, Konstantin G; Shingareva, Inna K; Neimark, Alexander V

    2002-02-25

    The process of capillary condensation/evaporation in cylindrical pores is considered within the idea of symmetry breaking. Capillary condensation/evaporation is treated as a morphological transition between the wetting film configurations of different symmetry. We considered two models: (i) the classical Laplace theory of capillarity and (ii) the Derjaguin model which takes into account the surface forces expressed in terms of the disjoining pressure. Following the idea of Everett and Haynes, the problem of condensation/evaporation is considered as a transition from bumps/undulations to lenses. Using the method of phase portraits, we discuss the mathematical mechanisms of this transition hidden in the Laplace and Derjaguin equations. Analyzing the energetic barriers of the bump and lens formation, it is shown that the bump formation is a prerogative of capillary condensation: for the vapor-liquid transition in a pore, the bump plays the same role as the spherical nucleus in a bulk fluid. We show also that the Derjaguin model admits a variety of interfacial configurations responsible for film patterning at specific conditions.

  5. Capillary condensation of short-chain molecules.

    Science.gov (United States)

    Bryk, Paweł; Pizio, Orest; Sokolowski, Stefan

    2005-05-15

    A density-functional study of capillary condensation of fluids of short-chain molecules confined to slitlike pores is presented. The molecules are modeled as freely jointed tangent spherical segments with a hard core and with short-range attractive interaction between all the segments. We investigate how the critical parameters of capillary condensation of the fluid change when the pore width decreases and eventually becomes smaller than the nominal linear dimension of the single-chain molecule. We find that the dependence of critical parameters for a fluid of dimers and of tetramers on pore width is similar to that of the monomer fluid. On the other hand, for a fluid of chains consisting of a larger number of segments we observe an inversion effect. Namely, the critical temperature of capillary condensation decreases with increasing pore width for a certain interval of values of the pore width. This anomalous behavior is also influenced by the interaction between molecules and pore walls. We attribute this behavior to the effect of conformational changes of molecules upon confinement.

  6. Spatial reconstruction of facial skin capillaries

    Directory of Open Access Journals (Sweden)

    Makarchuk O.I.

    2010-01-01

    Full Text Available To define structural and functional changes of skin capillaries in women of different age groups in this work intraoperational biopsy material of skin of 205 women at the age from 19 to 75 years, that was taken during standard surgery instrumentations for different defects of face and neck skin correction, was investigated. Skin material of cheek face region, temple region of head and anterior neck region was morphologically processed. To define parameters of dermal capillars and spatial reconstruction of intrapapillary capillary loops, serial sections was investigated with the help of morphometry. It was determined, that microcirculation age changes include structural disorders of intrapapillary capillary loops. Essential struc-tural and functional changes observed in skin of cheek region in women of 33-40 years and in temple region of head and anterior neck region in women of 41-50 years. It is typical at the patients with nicotinic dependence, ischemic heart disease, hypertonic disease, a diabetes, and also adiposity of a different degree essential infringement of microvessels bed structure of a skin that gives the basis for allocation of the given contingent of patients as group high intraoperative and postoperative risk at carrying out of operative interventions for correction of face skin involutive changes.

  7. Capillary Instability in Nanoimprinted Polymer Films

    Energy Technology Data Exchange (ETDEWEB)

    Alvine, Kyle J.; Ding, Yifu; Douglas, Jack F.; Ro, Hyun W.; Okerberg, Brian C.; Karim, Alamgir; Soles, Christopher L.

    2009-07-01

    Capillary forces play an active role in defining the equilibrium structure of nanoscale structures. This effect can be especially pronounced in soft materials such as polymers near or above their glass transition temperature Tg where material flow is possible. In these situations, the effect of surface tension can produce varied and complex capillary instabilities, even in relatively simple geometries such as parallel line-space grating patterns. Here we investigate a novel capillary instability that arises in polystyrene line-space gratings with a residual layer connecting these structures (created by nanoimprint lithography) upon thermal annealing of these patterns. This novel instability is characterized by the development of lateral undulations of the lines that culminates in the local coalescence of adjacent imprinted lines. An exact analytic model of this undulatory instability is not possible, but we introduce a simple physical model for this lateral instability based on the driving force to reduce the surface energy, as in the well-known Rayleigh-Plateau instability which is likewise surface energy driven. Good agreement is obtained between this simplified model and our observations. Our insights into the nature of this instability have implications for controlling the thermal stability of nanoscale patterns made by nanoimprint lithography or other lithography techniques.

  8. Simultaneous separation of five major ribonucleic acids by capillary electrophoresis with laser-induced fluorescence in the presence of electroosmotic flow: application to the rapid screening of 5S rRNA from ovarian cancer cells.

    Science.gov (United States)

    Shih, Ya-Chu; Liao, Ching-Ru; Chung, I-Che; Chang, Yu-Sun; Chang, Po-Ling

    2014-10-17

    RNA integrity is important in RNA studies because poor RNA quality may impact downstream methodologies. This study proposes a rapid and cost-effective method for the determination of RNA integrity based on CE-LIF in the presence of electroosmotic flow. The proposed method uses poly(ethylene) oxide (Mavg=4,000,000 Da) as a sieving matrix for total RNA separation. Ethidium bromide (μg mL(-1)) was dissolved in a polymer solution as an interchelating dye for on-column fluorescent labeling. The 28S rRNA, 18S rRNA, 5.8S rRNA, 5S rRNA and tRNA from the total human RNA extracted from the cells were fully separated using the proposed method. The lowest detectable concentration of total RNA achieved was 100 pg μL(-1) with a 6 min sample injection followed by on-column concentration. In addition, the temperature-induced degradation of total RNA was observed by CE-LIF. The electropherograms revealed more fragmentation of 28S and 18S rRNAs by temperature-induced hydrolysis compared with the 5.8S rRNA, 5S rRNA and tRNA. Therefore, the results indicated that RNA degradation should be considered for long-term, high-temperature incubations in RNA-related experiments involving RNA hybridization. The proposed method is furthermore, applied to the determination of 5S rRNA overexpressed in ovarian cancer cells as compared to the cervical cancer cells. Overall, CE-LIF is highly promising for rapid screening of ovarian cancers without tedious pre-amplification steps. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Proper Use of Capillary Number in Chemical Flooding

    Directory of Open Access Journals (Sweden)

    Hu Guo

    2017-01-01

    Full Text Available Capillary number theory is very important for chemical flooding enhanced oil recovery. The difference between microscopic capillary number and the microscopic one is easy to confuse. After decades of development, great progress has been made in capillary number theory and it has important but sometimes incorrect application in EOR. The capillary number theory was based on capillary tube bundles and Darcy’s law hypothesis, and this should always be kept in mind when used in chemical flooding EOR. The flow in low permeability porous media often shows obvious non-Darcy effects, which is beyond Darcy’s law. Experiments data from ASP flooding and SP flooding showed that remaining oil saturation was not always decreasing as capillary number kept on increasing. Relative permeability was proved function of capillary number; its rate dependence was affected by capillary end effects. The mobility control should be given priority rather than lowering IFT. The displacement efficiency was not increased as displacement velocity increased as expected in heavy oil chemical flooding. Largest capillary number does not always make highest recovery in chemical flooding in heterogeneous reservoir. Misuse of CDC in EOR included the ignorance of mobility ratio, Darcy linear flow hypothesis, difference between microscopic capillary number and the microscopic one, and heterogeneity caused flow regime alteration. Displacement of continuous oil or remobilization of discontinuous oil was quite different.

  10. Enhancing capillary blood collection: The influence of nicotinic acid and nonivamide.

    Science.gov (United States)

    Moro, Christian; Bass, Jessica; Scott, Anna Mae; Canetti, Elisa F D

    2017-01-19

    Nicotinic acid and nonivamide are often applied topically during capillary blood collection to induce vasodilation. These molecules may have an influence on immune effector cell activity in nearby tissues. This study investigates whether the induction of flushing by nicotinic acid and nonivamide causes an inflammatory response that influences the composition of immune cells present in a capillary blood sample. Females aged between 18 and 30 years old provided capillary blood samples. Experimental samples were taken from an earlobe treated with nicotinic acid and nonivamide with controls obtained from the untreated earlobe. Immunophenotypic analyses were conducted using polychromatic flow cytometry to determine whether any changes occurred in leucocyte subpopulations (CD3, CD4, CD8, CD19, CD56, and CD14) and granulocytic functional-related surface antigen markers (CD11b, CD18, CD16b, and CD66b). No significant differences were observed between experimental and control samples in the mean percent of parent for the lymphocyte, monocyte, or granulocyte subpopulations, or in the median fluorescence intensity of particular surface markers expressed on these leucocytes. The topical application of nicotinic acid and nonivamide is a possible method to improve capillary blood collection for immunological assessments. The use of these agents may increase the safety and compliance of patients who suffer from needle phobia or are unable to provide venous blood samples. © 2017 Wiley Periodicals, Inc.

  11. Development of novel separation techniques for biological samples in capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Huan -Tsung [Iowa State Univ., Ames, IA (United States)

    1994-07-27

    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good way to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.

  12. Moisture Transfer in Concrete: Numerical Determination of the Capillary Conductivity Coefficient

    Directory of Open Access Journals (Sweden)

    Simo Elie

    2017-03-01

    Full Text Available We numerically investigated moisture transfer in buildings made of concrete. We considered three types of concrete: normal concrete, pumice concrete and cellular concrete. We present the results of a 1-D liquid water flow in such materials. We evaluated the moisture distribution in building materials using the Runge-Kutta fourth-and-fifth-order method. The DOPRI5 code was used as an integrator. The model calculated the resulting moisture content and other moisture-dependent physical parameters. The moisture curves were plotted. The dampness data obtained was utilized for the numerical computation of the coefficient of the capillary conductivity of moisture. Different profiles of this coefficient are represented. Calculations were performed for four different values of the outdoor temperature: -5°C, 0°C, 5°C and 10°C. We determined that the curves corresponding to small time intervals of wetting are associated with great amplitudes of the capillary conductivity . The amplitudes of the coefficient of the capillary conductivity decrease as the time interval increases. High outdoor temperatures induce high amplitudes of the coefficient of the capillary conductivity.

  13. Evaluation of interactions between RAW264.7 macrophages and small molecules by capillary electrophoresis.

    Science.gov (United States)

    Wang, Feng-Qin; Li, Qiao-Qiao; Zhang, Qian; Wang, Yin-Zhen; Hu, Yuan-Jia; Li, Peng; Wan, Jian-Bo; Yang, Feng-Qing; Xia, Zhi-Ning

    2016-12-09

    In this study, the affinity interactions between RAW 264.7 macrophages and three small molecules including naringin, oleuropein and paeoniflorin were evaluated by affinity capillary electrophoresis (ACE), partial filling affinity capillary electrophoresis (PFACE) and frontal analysis capillary electrophoresis (FACE), respectively. The result indicated that ACE (varying concentrations of cell suspension were filled in the capillary as receptor) may not be suitable for the evaluation of interactions between cell and small molecules due to the high viscosity of cell suspension; PFACE can qualitatively evaluate the interaction, but the difference in viscosity between RAW264.7 suspension and buffer effects on the liner relationship between filling length and injection time, which makes the calculation of binding constant difficult. Furthermore, based on the PFACE results, naringin showed stronger interaction with macrophages than the other two molecules; taking advantage of the aggregation phenomenon of cell induced by electric field, FACE was successfully used to determine the stoichiometry (n = 5×10(9) ) and binding constant (Kb = 1×10(4) L/mol) of the interaction between RAW264.7 and naringin.

  14. Electromagnetohydrodynamic flow of blood and heat transfer in a capillary with thermal radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, A. [Department of Mathematics, Jadavpur University, Kolkata 700032 (India); Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in [Department of Mathematics, Jadavpur University, Kolkata 700032 (India); Institute of Mathematical Sciences, Chennai 600113 (India)

    2015-03-15

    This paper presents a comprehensive theoretical study on heat transfer characteristics together with fully developed electromagnetohydrodynamic flow of blood through a capillary, having electrokinetic effects by considering the constant heat flux at the wall. The effect of thermal radiation and velocity slip condition have been taken into account. A rigorous mathematical model for describing Joule heating in electro-osmotic flow of blood including the Poisson–Boltzmann equation, the momentum equation and the energy equation is developed. The alterations in the thermal transport phenomenon, induced by the variation of imposed electromagnetic effects, are thoroughly explained through an elegant mathematical formalism. Results presented here pertain to the case where the height of the capillary is much greater than the thickness of electrical double layer comprising the stern and diffuse layers. The essential features of the electromagnetohydrodynamic flow of blood and associated heat transfer characteristics through capillary are clearly highlighted by the variations in the non-dimensional parameters for velocity profile, temperature profile and the Nusselt number. The study reveals that the temperature of blood can be controlled by regulating Joule heating parameter. - Highlights: • Electromagnetohydrodynamic flow of blood in capillary is studied. • Potential electric field is applied for driving elecroosmotic flow of blood. • Effect of thermal radiation, Joule heating and velocity slip is investigated. • Thermal radiation bears the significant change in the temperature field.

  15. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis.

    Science.gov (United States)

    Scherer, James R; Liu, Peng; Mathies, Richard A

    2010-11-01

    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ~20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex(®) 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  16. Measurement of Capillary Radius and Contact Angle within Porous Media.

    Science.gov (United States)

    Ravi, Saitej; Dharmarajan, Ramanathan; Moghaddam, Saeed

    2015-12-01

    The pore radius (i.e., capillary radius) and contact angle determine the capillary pressure generated in a porous medium. The most common method to determine these two parameters is through measurement of the capillary pressure generated by a reference liquid (i.e., a liquid with near-zero contact angle) and a test liquid. The rate of rise technique, commonly used to determine the capillary pressure, results in significant uncertainties. In this study, we utilize a recently developed technique for independently measuring the capillary pressure and permeability to determine the equivalent minimum capillary radii and contact angle of water within micropillar wick structures. In this method, the experimentally measured dryout threshold of a wick structure at different wicking lengths is fit to Darcy's law to extract the maximum capillary pressure generated by the test liquid. The equivalent minimum capillary radii of different wick geometries are determined by measuring the maximum capillary pressures generated using n-hexane as the working fluid. It is found that the equivalent minimum capillary radius is dependent on the diameter of pillars and the spacing between pillars. The equivalent capillary radii of micropillar wicks determined using the new method are found to be up to 7 times greater than the current geometry-based first-order estimates. The contact angle subtended by water at the walls of the micropillars is determined by measuring the capillary pressure generated by water within the arrays and the measured capillary radii for the different geometries. This mean contact angle of water is determined to be 54.7°.

  17. A covalent modified hydrophilic capillary for enhanced capillary electrophoresis of biopolymers

    Institute of Scientific and Technical Information of China (English)

    Lian Guo Shan; Xue Yu; Yin Mao Wei; Xiao Hui Zheng; Jian Bin Zheng

    2009-01-01

    δ-Gluconolactone was covalently coupled to aminopropyl derivatized capillary,which created hydrophilic brushes on the inner wall of the capillary.The coated capillary was shown to generate a stable electroosmotic flow(EOF)in the investigated pH range of 2.0-9.0 and to suppress effectively the adsorption of proteins.And it enabled separation of some biopolymer mixtures including basic proteins,DNA and tryptic digested bovine serum albumin(BSA)within 15 min with efficiencies up to 450,000 plates/m.The intra-and inter-day reproducibility of the coating referring to the retention times of proteins were satisfactory with mean relative standard deviations(R.S.D.)of 0.8 and 1.7%,respectively.

  18. Capillary climb dynamics in the limits of prevailing capillary and gravity force.

    Science.gov (United States)

    Bijeljic, B; Markicevic, B; Navaz, H K

    2011-05-01

    The dynamics of capillary climb of a wetting liquid into a porous medium that is opposed by gravity force is studied numerically. We use the capillary network model, in which an actual porous medium is represented as a network of pores and throats, each following a predefined size distribution function. The liquid potential in the pores along the liquid interface within the network is calculated as a result of capillary and gravity forces. The solution is general, and accounts for changes in the climbing height and climbing velocity. The numerical results for the capillary climb reveal that there are at least two distinct flow mechanisms. Initially, the flow is characterized by high climbing velocity, in which the capillary force is higher than the gravity force, and the flow is the viscous force dominated. For this single-phase flow, the Washburn equation can be used to predict the changes of climbing height over time. Later, for longer times and larger climbing height, the capillary and gravity forces become comparable, and one observes a slower increase in the climbing height as a function of time. Due to the two forces being comparable, the gas-liquid sharp interface transforms into flow front, where the multiphase flow develops. The numerical results from this study, expressed as the climbing height as a power law function of time, indicate that the two powers, which correspond to the two distinct mechanisms, differ significantly. The comparison of the powers with experimental data indicates good agreement. Furthermore, the power value from the Washburn solution is also analyzed, where it should be equal to 1/2 for purely viscous force driven flow. This is in contrast to the power value of ∼0.43 that is found experimentally. We show from the numerical solution that this discrepancy is due to the momentum dissipation on the liquid interface.

  19. Evaluation of Tillandsia capillaris Ruiz amd Pav. f. capillaris as biomonitor of atmospheric pollution in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Pignata, M.L. [Univ. Nacional de Cordoba, Cordoba (Argentina). Facultad de Ciencias Exactas, Fisicas y Naturales]|[Instituto Multidisciplinario de Biologia Vegetal (IMBIV-UNC), Cordoba (Argentina); Wannaz, E.D.; Martinez, M.S.; Caminotti, G. [Univ. Nacional de Cordoba, Cordoba (Argentina). Facultad de Ciencias Exactas, Fisicas y Naturales

    2002-07-01

    The behaviour of Tillandsia capillaris Ruiz and Pav. f. capillaris, when exposed to atmospheric pollutants, was assessed by measuring chemical parameters indicating foliar damage and the contents of some heavy metals. Samples were transplanted to three sites in the City of Cordoba and were collected back after 15, 30, 60 and 90 days of exposure. At the same time, samples coming from the collection site were analyzed for each of said exposure times. Chlorophylls, hydroperoxy conjugated dienes, water contents, malondialdehyde, sulfur, Cu, Pb, Ni, Co, Mn, Zn and Fe were measured in the samples. A Foliar Damage Index was calculated from some of these parameters. (orig.)

  20. Capillary origami: superhydrophobic ribbon surfaces and liquid marbles

    Directory of Open Access Journals (Sweden)

    Glen McHale

    2011-03-01

    Full Text Available In the wetting of a solid by a liquid it is often assumed that the substrate is rigid. However, for an elastic substrate the rigidity depends on the cube of its thickness and so reduces rapidly as the substrate becomes thinner as it approaches becoming a thin sheet. In such circumstances, it has been shown that the capillary forces caused by a contacting droplet of a liquid can shape the solid rather than the solid shaping the liquid. A substrate can be bent and folded as a (pinned droplet evaporates or even instantaneously and spontaneously wrapped on contact with a droplet. When this effect is used to create three dimensional shapes from initially flat sheets, the effect is called capillary origami or droplet wrapping.In this work, we consider how the conditions for the spontaneous, capillary induced, folding of a thin ribbon substrate might be altered by a rigid surface structure that, for a rigid substrate, would be expected to create Cassie–Baxter and Wenzel effects. For smooth thin substrates, droplet wrapping can occur for all liquids, including those for which the Young’s law contact angle (defined by the interfacial tensions is greater than 90° and which would therefore normally be considered relatively hydrophobic. However, consideration of the balance between bending and interfacial energies suggests that the tendency for droplet wrapping can be suppressed for some liquids by providing the flexible solid surface with a rigid topographic structure. In general, it is known that when a liquid interacts with such a structure it can either fully penetrate the structure (the Wenzel case or it can bridge between the asperities of the structure (the Cassie–Baxter case.In this report, we show theoretically that droplet wrapping should occur with both types of solid–liquid contact. We also derive a condition for the transition between the Cassie–Baxter and Wenzel type droplet wrapping and relate it to the same transition condition

  1. Capillary origami: superhydrophobic ribbon surfaces and liquid marbles

    Science.gov (United States)

    Newton, Michael I; Shirtcliffe, Neil J; Geraldi, Nicasio R

    2011-01-01

    Summary In the wetting of a solid by a liquid it is often assumed that the substrate is rigid. However, for an elastic substrate the rigidity depends on the cube of its thickness and so reduces rapidly as the substrate becomes thinner as it approaches becoming a thin sheet. In such circumstances, it has been shown that the capillary forces caused by a contacting droplet of a liquid can shape the solid rather than the solid shaping the liquid. A substrate can be bent and folded as a (pinned) droplet evaporates or even instantaneously and spontaneously wrapped on contact with a droplet. When this effect is used to create three dimensional shapes from initially flat sheets, the effect is called capillary origami or droplet wrapping. In this work, we consider how the conditions for the spontaneous, capillary induced, folding of a thin ribbon substrate might be altered by a rigid surface structure that, for a rigid substrate, would be expected to create Cassie–Baxter and Wenzel effects. For smooth thin substrates, droplet wrapping can occur for all liquids, including those for which the Young’s law contact angle (defined by the interfacial tensions) is greater than 90° and which would therefore normally be considered relatively hydrophobic. However, consideration of the balance between bending and interfacial energies suggests that the tendency for droplet wrapping can be suppressed for some liquids by providing the flexible solid surface with a rigid topographic structure. In general, it is known that when a liquid interacts with such a structure it can either fully penetrate the structure (the Wenzel case) or it can bridge between the asperities of the structure (the Cassie–Baxter case). In this report, we show theoretically that droplet wrapping should occur with both types of solid–liquid contact. We also derive a condition for the transition between the Cassie–Baxter and Wenzel type droplet wrapping and relate it to the same transition condition known to

  2. An axial approach to detection in capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, John Aaron [Iowa State Univ., Ames, IA (United States)

    1993-05-01

    Our approach involves on-axis illumination of the compounds inside the capillary detection region and is applied to absorbance and fluorescence detection. Absorbance measurements were made by focussing an incident laser beam into one capillary end; by using signals collected over the entire length of analyte band, this enhances the analytical path length of conventional absorbance detection 60x. This instrument offers a 15x improvement in detection limits. Three fluorescence detection experiments are discussed, all of which involve insertion of an optical fiber into capillary. The first uses a high refractive index liquid phase to obtain total internal reflectance along capillary axis, this reducing light scatter. The second uses a charge-coupled device camera for simultaneous imaging of a capillary array (this may be useful in genome sequencing, etc.). The third is a study of fluid motion inside the capillary under pressure-driven and electroosmotic flow. The thesis is divided into four parts. Figs, tabs.

  3. Separation and analysis of triazine herbcide residues by capillary electrophoresis.

    Science.gov (United States)

    Elbashir, Abdalla A; Aboul-Enein, Hassan Y

    2015-06-01

    Triazines are widely used in agriculture around the world as selective pre- and post-emergence herbicides for the control of broad leaf and grassy weeds. With high toxicity and persistence, triazines can contaminate the environment and crops, so the development of rapid and sensitive methods for the determination of different triazines is necessary. Capillary electrophoresis comprises a group of techniques used to separate chemical mixtures. Analytical separation is based on different electrophoretic mobilities. This review focuses on the analysis of triazine herbicides with different modes of capillary electrophoresis, including capillary zone electrophoresis, micellar electrokinetic capillary electrophoresis, capillary electrochromatography and nonaqueous capillary electrophoresis. Determinations of triazines in various matrices such as surface water, groundwater, vegetables, soil and grains are emphasized.

  4. Fluorescent polymer coated capillaries as optofluidic refractometric sensors.

    Science.gov (United States)

    Rowland, Kristopher J; François, Alexandre; Hoffmann, Peter; Monro, Tanya M

    2013-05-06

    A capillary microresonator platform for refractometric sensing is demonstrated by coating the interior of thick-walled silica capillaries with a sub-wavelength layer of high refractive index, dye-doped polymer. No intermediate processing, such as etching or tapering, of the capillary is required. Side illumination and detection of the polymer layer reveals a fluorescence spectrum that is periodically modulated by whispering gallery mode resonances within the layer. Using a Fourier technique to calculate the spectral resonance shifts, the fabricated capillary resonators exhibited refractometric sensitivities up to approximately 30 nm/RIU upon flowing aqueous glucose through them. These sensors could be readily integrated with existing biological and chemical separation platforms such as capillary electrophoresis and gas chromatography where such thick walled capillaries are routinely used with polymer coatings. A review of the modelling required to calculate whispering gallery eigenmodes of such inverted cylindrical resonators is also presented.

  5. Colloid Mobilization and Transport during Capillary Fringe Fluctuations

    Science.gov (United States)

    Aramrak, Surachet; Flury, Markus

    2016-04-01

    Capillary fringe fluctuations due to changing water tables lead to displacement of air-water interfaces in soils and sediments. These moving air-water interfaces can mobilize colloids. We visualized colloids interacting with moving air-water interfaces during capillary fringe fluctuations by confocal microscopy. We simulated capillary fringe fluctuations in a glass-bead filled column. Confocal images showed that the capillary fringe fluctuations affect colloid transport behavior. Hydrophilic negatively-charged colloids initially suspended in the aqueous phase were deposited at the solid-water interface after a drainage passage, but then were removed by subsequent capillary fringe fluctuations. The colloids that were initially attached to the wet or dry glass bead surface were detached by moving air-water interfaces in the capillary fringe. Hydrophilic negatively-charged colloids did not attach to static air-bubbles, but hydrophobic negatively-charged and hydrophilic positively-charged colloids did.

  6. Method for analysing glycoprotein isoforms by capillary electrophoresis

    OpenAIRE

    Frutos, Mercedes de; Díez-Masa, José Carlos; Morales-Cid, Gabriel

    2011-01-01

    [EN] The present invention relates to a new method for the purification, concentration, separation and determination of the isoforms of alpha-1-acid glycoprotein (AGP) in human blood serum samples using capillary electrophoresis. The new method is based on the immunocapture and preconcentration of the sample within the separation capillary by using an immunoadsorbent phase magnetically immobilized within the electrophoresis capillary and the subsequent desorption and separation of the glycopr...

  7. Creeping motion of long bubbles and drops in capillary tubes

    DEFF Research Database (Denmark)

    Westborg, Henrik; Hassager, Ole

    1989-01-01

    The flow of inviscid bubbles and viscous drops in capillary tubes has been simulated by a Galerkin finite element method with surface tension included at the bubble/liquid interface. The results show good agreement with published experimental results. At low capillary numbers the front and the re...... and the snap-off time increases with increasing capillary number. Snap-off without a sudden decrease of the flow rate does not seem to occur in constrictions of circular cross section....

  8. Modified monolithic silica capillary for preconcentration of catecholamines

    Institute of Scientific and Technical Information of China (English)

    Wei Chang; Tusyo-shi Komazu

    2009-01-01

    Preconcentration of catecholamines by the modified monolithic silica in the capillary was investigated in this study. In order to achieve a microchip-based method for determining catecholamines in the saliva, the monolithic silica was fabricated in the capillary and the monolithic silica was chemically modified by on-column reaction with phenylboronate. Different modified methods were compared. The concentration conditions were optimized. This study indicates the applicability of the modified monolithic silica capillary when it was used to concentrate catecholamines.

  9. A Prediction Model of the Capillary Pressure J-Function

    Science.gov (United States)

    Xu, W. S.; Luo, P. Y.; Sun, L.; Lin, N.

    2016-01-01

    The capillary pressure J-function is a dimensionless measure of the capillary pressure of a fluid in a porous medium. The function was derived based on a capillary bundle model. However, the dependence of the J-function on the saturation Sw is not well understood. A prediction model for it is presented based on capillary pressure model, and the J-function prediction model is a power function instead of an exponential or polynomial function. Relative permeability is calculated with the J-function prediction model, resulting in an easier calculation and results that are more representative. PMID:27603701

  10. Novel Micro-Capillary Electrochromatography for Mars Organic Detector Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research proposes to develop a powerful new technology - next generation Micro-Capillary Electrochromatography - a high performance and low power...

  11. Novel Micro-Capillary Electrochromatography for Mars Organic Detector Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research proposes to develop a powerful new technology - next generation Micro-Capillary Electrochromatography ? a high performance and low power...

  12. The study of polyoxometalates formation using capillary zone electrophoresis.

    Science.gov (United States)

    Zdanov, Artem A; Shuvaeva, Olga V

    2014-09-01

    The formation process of polyoxometalates [PMo12 O40 ](3-) and [PMo12 - x Vx O40 ](-3-x) has been studied in aqueous solutions of 0.1 M malonate buffer at pH 2.8-3.0 using CZE. Two different approaches, pre-capillary and in-capillary, were examined and compared. In precapillary mode, the reaction mixture of the reactants and reaction products was injected into the capillary followed by the separation procedure. In in-capillary mode, the sequential input of the reagents and running electrolyte into the capillary and the species separation occurs simultaneously. The optimal parameters of in-capillary separation were established as functions of applied voltage and the length of the intermediate buffer zone between the reagents in the capillary. As a result the best-compromise conditions for the separation of the mixtures containing the reactants, intermediates, and reaction products, in order to achieve the best efficiency, symmetry, and peak areas, were achieved at -18 kV and the input parameter of 900 mbar·s. It was also shown that in-capillary mode is more informative than pre-capillary mode for studying the complex compound formation process.

  13. Capillary Micro-Flow Through a Fiber Bundle(Ⅰ)

    Institute of Scientific and Technical Information of China (English)

    ZHU Ying-dan; WANG Ji-hui; TAN Hua; GAO Guo-qiang

    2004-01-01

    The present work considered the capillary micro-flow through a fiber bundle. The resin heights in the fiber bundle as a function of time were used to determine the experimental values of capillary pressure and the permeability by the nonlinear regression fitting method. The fitting curves showed a good agreement with experiments. However, these values of capillary pressure from short- time experiments were much lower than the theoretical results from the Yang-Laplace Equation. More accurate capillary pressure was predicted from the presented long-run experiment.

  14. High Performance Wafer-Based Capillary Electrochromatography Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase II research comprises designing, constructing, and testing a chip-based capillary electrochromatography (CEC) prototype for separation and analysis of...

  15. Capillary growth in human skeletal muscle: physiological factors and the balance between pro-angiogenic and angiostatic factors

    DEFF Research Database (Denmark)

    Hellsten, Ylva; Hoier, Birgitte

    2014-01-01

    In human skeletal muscle, the capillary net readily adapts according to the level of muscular activity to allow for optimal diffusion conditions for oxygen from the blood to the muscle. Animal studies have demonstrated that stimulation of capillary growth in skeletal muscle can occur either...... by mechanical or by chemical signalling. Mechanical signals originate from shear stress forces on the endothelial cell layer induced by the blood flowing through the vessel, but include also mechanical stretch and compression of the vascular structures and the surrounding tissue, as the muscle contracts...

  16. Effective viscosity of magnetic nanofluids through capillaries.

    Science.gov (United States)

    Patel, Rajesh

    2012-02-01

    The simultaneous effect of magnetic field and temperature on the capillary viscosity of magnetic nanofluid is an important parameter for a new class of applications such as nanoduct flow, nanomotors, micro- and nanofluidic devices, for transformer cooling, magnetic targeted drug delivery, etc. The effective viscosity of a nanofluid is explained based on the rotation of the particles and the effect of torque on it due to an externally applied magnetic field. Two types of fluids are used here, temperature-sensitive and non-temperature-sensitive magnetic nanofluids. In both types of fluids, decrease in effective viscosity with temperature is observed, but in both cases the mechanism for the decrement is quite different. One is due to temperature dependence of the magnetic moment and the other is due to removal of the secondary surfactant. For temperature-sensitive magnetic nanofluids, a Curie temperature of ~80 °C is extracted from this study. For non-temperature-sensitive magnetic nanofluids ~65% of the secondary surfactant is removed for a change in temperature, ΔT = 40 °C. This is analogous with removal of a drug from magnetic particles for targeted drug delivery. Further, a linear dependence of effective viscosity with different capillary size and ξ (angle between magnetic field and flow direction, ξε[0,π/2]) is also observed. This linear dependence can also be a good approximation for the study of magnetic drug targeting, as in the human body the capillaries are of different sizes, and the externally applied magnetic field is not always parallel or perpendicular to the drug flow direction.

  17. Capillary electrophoresis-mass spectrometry of carbohydrates.

    Science.gov (United States)

    Zaia, Joseph

    2013-01-01

    The development of methods for capillary electrophoresis (CE) with on-line mass spectrometric detection (CE/MS) is driven by the need for accurate, robust, and sensitive glycomics analysis for basic biomedicine, biomarker discovery, and analysis of recombinant protein therapeutics. One important capability is to profile glycan mixtures with respect to the patterns of substituents including sialic acids, acetate, sulfate, phosphate, and other groups. There is additional need for an MS-compatible separation system capable of resolving carbohydrate isomers. This chapter summarizes applications of CS/MS to analysis of carbohydrates, glycoproteins, and glycopeptides that have appeared since 2008. Readers are referred to recent comprehensive reviews covering earlier publications.

  18. Elastic deformation due to tangential capillary forces

    CERN Document Server

    Das, Siddhartha; Andreotti, Bruno; Snoeijer, Jacco H

    2011-01-01

    A sessile liquid drop can deform the substrate on which it rests if the solid is sufficiently "soft". In this paper we compute the detailed spatial structure of the capillary forces exerted by the drop on the solid substrate using a model based on Density Functional Theory. We show that, in addition to the normal forces, the drop exerts a previously unaccounted tangential force. The resultant effect on the solid is a pulling force near the contact line directed towards the interior of the drop, i.e. not along the interface. The resulting elastic deformations of the solid are worked out and illustrate the importance of the tangential forces.

  19. Intraneural capillary hemangioma of the cauda equina.

    Science.gov (United States)

    Mastronardi, L; Guiducci, A; Frondizi, D; Carletti, S; Spera, C; Maira, G

    1997-01-01

    A case of intraneural capillary hemangioma involving the dorsal root of a spinal nerve of the cauda equina is reported. The patient was a 41-year-old man with a 3-month history of intermittent left lumbosciatalgia. MRI and CT myelography showed a space-occupying mass at the level of the cauda equina. Laminectomy of L5 and complete removal of the lesion were performed without neurological problems. The clinical, diagnostic, and therapeutic aspects of hemangiomas of the cauda equina are analyzed.

  20. Subsidence and capillary effects in chalks

    CERN Document Server

    Delage, Pierre; Cui, Yu Jun

    2008-01-01

    Based on the concepts of the mechanics of unsaturated soils where capillary phenomena arise between the wetting fluid (water) and the non-wetting one (air), the subsidence of chalks containing oil (non-wetting fluid) during water injection (wetting fluid) is analysed. It is shown that the collapse phenomenon of unsaturated soils under wetting provides a physical explanation and a satisfactory prediction of the order of magnitude of the subsidence of the chalk. The use of a well established constitutive model for unsaturated soils allows a description of the hydro-mechanical history of the chalk, from its deposition to the oil exploitation.

  1. Capillary floating and the billiard ball problem

    CERN Document Server

    Gutkin, Eugene

    2010-01-01

    We establish a connection between capillary floating in neutral equilibrium and the billiard ball problem. This allows us to reduce the question of floating in neutral equilibrium at any orientation with a prescribed contact angle for infinite homogeneous cylinders to a question about billiard caustics for their orthogonal cross-sections. We solve the billiard problem. As an application, we characterize the possible contact angles and exhibit an infinite family of real analytic non-round cylinders that float in neutral equilibrium at any orientation with constant contact angles.

  2. Experimental study on capillary filling in nanochannels

    Science.gov (United States)

    Yang, Min; Cao, Bing-Yang; Wang, Wei; Yun, He-Ming; Chen, Bao-Ming

    2016-10-01

    We investigated the capillary filling kinetics of deionized water in nanochannels with heights of 50-120 nm. The measured position of the moving meniscus was proportional to the square root of time, as predicted by the LW equation. However, the extracted slopes were significantly smaller than the predictions based on the bulk properties. This unusual behavior was found to be mainly caused by the electro-viscous effect and dynamic contact angle, which was significantly larger than the static angle. In addition, when the filling distance reached about 600 μm, bubbles tended to be formed, leading to the main meniscus was almost immobile.

  3. Capillary Network, Cancer and Kleiber Law

    CERN Document Server

    Dattoli, G; Licciardi, S; Guiot, C; Deisboeck, T S

    2014-01-01

    We develop a heuristic model embedding Kleiber and Murray laws to describe mass growth, metastasis and vascularization in cancer. We analyze the relevant dynamics using different evolution equations (Verhulst, Gompertz and others). Their extension to reaction diffusion equation of the Fisher type is then used to describe the relevant metastatic spreading in space. Regarding this last point, we suggest that cancer diffusion may be regulated by Levy flights mechanisms and discuss the possibility that the associated reaction diffusion equations are of the fractional type, with the fractional coefficient being determined by the fractal nature of the capillary evolution.

  4. Design and evaluation of capillary electrophoresis in dynamically coated capillaries coupled with chemiluminescence detection.

    Science.gov (United States)

    Liu, Haiyan; Han, Ning; Zhang, Lingyi; Du, Yiping; Zhang, Weibing

    2010-11-08

    A dynamic coating capillary electrophoresis coupled with a simplified on-line chemiluminescence detection system was designed and evaluated. In the proposed system, poly-vinylpyrrolidone was used as dynamic coating substance in the separation buffer to reduce the unwanted protein non-specific adsorption, which was first applied in capillary electrophoresis coupling with on-line chemiluminescence detection. In order to avoid complex processing, an ordinary plastic cuvette was modified as a three-way joint. The chemiluminescence reaction conditions and capillary electrophoresis separation conditions were investigated in detail. The results showed that the coated capillary can be injected protein samples at least 30 times continuously with good repeatability. Under optimal conditions, the chemiluminescence relative intensity was linear with the concentration of hemoglobin in the range of 4-1850 μg mL(-1) and the detection limit was 2.0 μg mL(-1) (S/N=3). The relative standard deviation of migration times and peak heights for 40 μg mL(-1) hemoglobin were 2.5% and 4.1% (n=11) respectively. Interference of matrix effects was overcome by the calibration according to standard addition methods. Afterwards, the method was validated successfully and was applied to detect the concentration of hemoglobin in the serum of haemolytic patients.

  5. On-capillary derivatisation as an approach to enhancing sensitivity in capillary electrophoresis.

    Science.gov (United States)

    Glatz, Zdeněk

    2015-03-01

    Separation technologies play an important role in revealing biological processes at various omic levels, in pharmacological and clinical research. In this context, CE is a strong candidate for analyses of samples with rapidly increasing complexity. Even though CE is well known for its many advantages in this regard, the sensitivity of CE analyses is insufficient for many applications. Accordingly, there are generally three main options for enhancing the sensitivity of CE analyses - using special detection techniques, using sample pre-concentration and derivatisation. Derivatisation is often the method of choice for many laboratories, since it is simple and provides several advantages such as small sample volume demand and the possibility of automation. Although it can be performed in different ways depending on where the reaction takes place, this article reviews one of the simplest and at the same time most useful approaches on-capillary derivatisation. Even if in many cases the use of on-capillary derivatisation alone is enough to improve the detection sensitivity, on other occasions it needs to be employed in combination with the other above-mentioned strategies. After a simple discussion of derivatisation in general, special attention is focused on the on-capillary approach and methodologies available for on-capillary reactant mixing. Its applications in various fields are also described.

  6. Comparison of three modifications of fused-silica capillaries and untreated capillaries for protein profiling of maize extracts by capillary electrophoresis.

    Science.gov (United States)

    Pobozy, Ewa; Sentkowska, Aleksandra; Piskor, Anna

    2014-09-01

    In this work, capillary electrophoresis was applied to protein profiling of fractionated extracts of maize. A comparative study on the application of uncoated fused-silica capillaries and capillaries modified with hydroxypropylmethylcellulose, ω-iodoalkylammonium salt and a commercially available neutral capillary covalently coated with polyacrylamide is presented. The coating stability, background electrolyte composition, and separation efficiency were investigated. It was found that for zeins separation, the most stable and efficient was the capillary coated with polyacrylamide. Finally, the usefulness of these methods was studied for the differentiation of zein fraction in transgenic and nontransgenic maize. Zeins extracted from maize standards containing 0 and 5% m/m genetic modification were successfully separated, but slight differences were observed in terms of the zein content. Albumin and globulin fractions were analyzed with the use of unmodified fused-silica capillary with borate buffer pH 9 and the capillary coated with polyacrylamide with phosphate buffer pH 3. In the albumin fraction, additional peaks were found in genetically modified samples.

  7. A new sieving matrix for DNA sequencing, genotyping and mutation detection and high-throughput genotyping with a 96-capillary array system

    Energy Technology Data Exchange (ETDEWEB)

    Gao, David [Iowa State Univ., Ames, IA (United States)

    1999-11-08

    Capillary electrophoresis has been widely accepted as a fast separation technique in DNA analysis. In this dissertation, a new sieving matrix is described for DNA analysis, especially DNA sequencing, genetic typing and mutation detection. A high-throughput 96 capillary array electrophoresis system was also demonstrated for simultaneous multiple genotyping. The authors first evaluated the influence of different capillary coatings on the performance of DNA sequencing. A bare capillary was compared with a DB-wax, an FC-coated and a polyvinylpyrrolidone dynamically coated capillary with PEO as sieving matrix. It was found that covalently-coated capillaries had no better performance than bare capillaries while PVP coating provided excellent and reproducible results. The authors also developed a new sieving Matrix for DNA separation based on commercially available poly(vinylpyrrolidone) (PVP). This sieving matrix has a very low viscosity and an excellent self-coating effect. Successful separations were achieved in uncoated capillaries. Sequencing of M13mp18 showed good resolution up to 500 bases in treated PVP solution. Temperature gradient capillary electrophoresis and PVP solution was applied to mutation detection. A heteroduplex sample and a homoduplex reference were injected during a pair of continuous runs. A temperature gradient of 10 C with a ramp of 0.7 C/min was swept throughout the capillary. Detection was accomplished by laser induced fluorescence detection. Mutation detection was performed by comparing the pattern changes between the homoduplex and the heteroduplex samples. High throughput, high detection rate and easy operation were achieved in this system. They further demonstrated fast and reliable genotyping based on CTTv STR system by multiple-capillary array electrophoresis. The PCR products from individuals were mixed with pooled allelic ladder as an absolute standard and coinjected with a 96-vial tray. Simultaneous one-color laser-induced fluorescence

  8. Pulmonary capillary recruitment in response to hypoxia in healthy humans: a possible role for hypoxic pulmonary venoconstriction?

    DEFF Research Database (Denmark)

    Taylor, Bryan J; Kjaergaard, Jesper; Snyder, Eric M;

    2011-01-01

    capillary blood volume (Vc) were measured before and after saline infusion and hypoxic-exposure by a rebreathing method. Pulmonary artery systolic pressure (sPpa) and left ventricular (LV) diastolic function were assessed before and after hypoxic-exposure via echocardiography. Saline infusion increased Q......Ppa and LV diastolic function. In conclusion, hypoxia-induced pulmonary capillary recruitment in humans is only partly accounted for by changes in Q, sPpa and LV diastolic function. We speculate that hypoxic pulmonary venoconstriction may play a role in such recruitment.......We examined mechanisms by which hypoxia may elicit pulmonary capillary recruitment in humans. On separate occasions, twenty-five healthy adults underwent exposure to intravenous saline infusion (30 ml/kg ∼ 15 min) or 17-h normobaric hypoxia ( [FIO2 = 12.5%). Cardiac output (Q) and pulmonary...

  9. Capillary electrophoresis-diode array detection--electrospray mass spectrometry for the analysis of selected tropane alkaloids in plant extracts.

    Science.gov (United States)

    Mateus, L; Cherkaoui, S; Christen, P; Veuthey, J L

    1999-11-01

    Capillary zone electrophoresis, coupled to UV and interfaced with electrospray ionization mass spectrometry (ESI-MS), is described for the simultaneous analysis of hyoscyamine and scopolamine. On-line UV detection occurred at 22 cm from the inlet of the capillary and ESI-MS monitoring was performed along the entire length of the capillary (85 cm). An alkaline solution of 40 mM ammonium acetate at pH 8.5 was suitable for the analysis of the alkaloids under consideration. Under the optimized conditions, including CE and ESI-MS parameters, the two alkaloids were resolved within a short time and with very high sensitivity. The differentiation of hyoscyamine and its positional isomer littorine, commonly encountered in plant material, is also presented using up-front collision-induced dissociation. Finally, the developed method was applied to the analysis of these alkaloids in Belladonna leaf extract and in Datura candida x D. aurea hairy root extract.

  10. Glomerular Damage in Experimental Proliferative Glomerulonephritis Under Glomerular Capillary Hypertension

    Directory of Open Access Journals (Sweden)

    Pei-Rong Wang

    2015-03-01

    Full Text Available Background/Aims: Immunologically and hemodynamically mediated the destruction of glomerular architecture is thought to be the major causes of end-stage renal failure. The purpose of this study is to evaluate the effect of glomerular hypertension on glomerular injury and the progression of glomerular sclerosis after Thy-1 nephritis was induced. Method: Thy-1 nephritis was induced in the stroke-prone spontaneously hypertensive rat strain (SHR-SP (group SP and in age-matched Wistar-Kyoto (WKY (group WKY rats, following unilateral nephrectomy (UNX, and a vehicle was injected alone in UNX SHR-SP as control (group SC. Result: The degree of glomerular damage in response to a single dose of anti-thy-1 antibody, and its functional consequences (eg. proteinuria, diminished GFR are more pronounced in group SP than normotensive group WKY and hypertensive group SC without mesangial cell injury. While normotensive group WKY rats recovered completely from mesangial cell injury on day 28-42, glomeruli in group SP kept on persistent macrophage infiltration, α-SMA expression on day 42-56. In addition, glomerular capillary repair with the GECs was rarely seen in pronouncedly proliferative and sclerostic areas. The incidence of glomerular sclerosis and the level of proteinuria were markedly increased by day 56 in the group SP. Conclusions: Our results demonstrate that glomerular hypertension aggravate glomerular damage and glomerulosclerosis in this model of Thy 1 nephritis.

  11. Capillary surface discontinuities above reentrant corners

    Science.gov (United States)

    Korevaar, H. J.

    1982-01-01

    A particular configuration of a vertical capillary tube for which S is the equilibrium interface between two fluids in the presence of a downward pointing gravitational field was investigated. S is the graph a function u whose domain is the (horizontal) cross section gamma of the tube. The mean curvature of S is proportional to its height above a fixed reference plane and lambda is a prescribed constant and may be taken between zero and pi/2. Domains gamma for which us is a bounded function but does not extend continuously to d gamma are sought. Simple domains are found and the behavior of u in those domains is studied. An important comparison principle that has been used in the literature to derive many of the results in capillarity is reviewed. It allows one to deduce the approximate shape of a capillary surface by constructing comparison surfaces with mean curvature and contact angle close to those of the (unknown) solution surface. In the context of nonparametric problems the comparison principle leads to height estimates above and below for the function u. An example from the literature where these height estimates have been used successfully is described. The promised domains for which the bounded u does not extend continuously to the boundary are constructed. The point on the boundary at which u has a jump discontinuity will be the vertext of a re-entrant corner having any interior angle theta pi. Using the comparison principle the behavior of u near this point is studied.

  12. Observations of gravity-capillary lump interactions

    CERN Document Server

    Masnadi, Naeem

    2016-01-01

    In this experimental study, we investigate the interaction of gravity-capillary solitary waves generated by two surface pressure sources moving side by side at constant speed. The nonlinear response of a water surface to a single source moving at a speed just below the minimum phase speed of linear gravity-capillary waves in deep water ($c_{min}\\approx23$ cm s$^{-1}$) consists of periodic generation of pairs of three-dimensional solitary waves (or lumps) in a V-shaped pattern downstream of the source. In the reference frame of the laboratory, these unsteady lumps propagate in a direction oblique to the motion of the source. In the present experiments, the strength of the two sources is adjusted to produce nearly identical responses and the free surface deformations are visualized using photography-based techniques. The first lumps generated by the two sources move in intersecting directions that make a half angle of approximately 15 degrees and collide in the center-plane between the sources. A steep depressi...

  13. Heterogeneity of capillary spacing in the hypertrophied plantaris muscle from young-adult and old rats.

    NARCIS (Netherlands)

    Degens, H.; Morse, C.I.; Hopman, M.T.E.

    2009-01-01

    Heterogeneity of capillary spacing may affect tissue oxygenation. The determinants of heterogeneity of capillary spacing are, however, unknown. To investigate whether 1) impaired angiogenesis and increased heterogeneity of capillary spacing delays development of hypertrophy during aging and 2)

  14. Malignant Hemispheric Cerebral Infarction Associated with Idiopathic Systemic Capillary Leak Syndrome

    Directory of Open Access Journals (Sweden)

    Kei Miyata

    2013-10-01

    Full Text Available Idiopathic systemic capillary leak syndrome (ISCLS is a rare condition that is characterized by unexplained episodic capillary hyperpermeability due to a shift of fluid and protein from the intravascular to the interstitial space. This results in diffuse general swelling, fetal hypovolemic shock, hypoalbuminemia, and hemoconcentration. Although ISCLS rarely induces cerebral infarction, we experienced a patient who deteriorated and was comatose as a result of massive cerebral infarction associated with ISCLS. In this case, severe hypotensive shock, general edema, hemiparesis, and aphasia appeared after serious antecedent gastrointestinal symptoms. Progressive life-threatening ischemic cerebral edema required decompressive hemicraniectomy. The patient experienced another episode of severe hypotension and limb edema that resulted in multiple extremity compartment syndrome. Treatment entailed forearm and calf fasciotomies. Cerebral edema in the ischemic brain progresses rapidly in patients suffering from ISCLS. Strict control of fluid volume resuscitation and aggressive diuretic therapy may be needed during the post-leak phase of fluid remobilization.

  15. Membrane-mediated capillary electrophoresis: interaction of cationic peptides with bicelles.

    Science.gov (United States)

    Mills, John O; Holland, Lisa A

    2004-05-01

    Electrokinetic capillary chromatography is applied to determine the membrane affinity of peptides using both 1,2-dihexanoyl-sn-glycero-3-phosphocholine (DHPC) micelles and DHPC/1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) bicelles under controlled conditions. The effect of temperature and the bicelle q value in surface association with cationic peptides is studied. The cationic peptides selected have a well-defined membrane structure (indolicidin), induced secondary structure (melittin, magainin 2), or do not possess classical secondary structure (atrial natriuretic peptide (ANP) 1-28, 4-28, 5-27). Electrokinetic capillary chromatography facilitated by DMPC and DHPC additives provides a rapid means of estimating lipophilicity and screening for peptides that have membrane affinity.

  16. Capillary electrophoretic study of individual exocytotic events in single mast cells

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Andrea Ming-Wei [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The peak profile of individual degranulation events from the on-column release of serotonin from single rat peritoneal mast cells (RPMCs) was monitored using capillary electrophoresis with laser-induced native fluorescence detection (CE-LINF). Serotonin, an important biogenic amine, is contained in granules (0.25 fL) within RPMCs and is extruded by a process termed exocytosis. The secretagogue, Polymyxin B sulfate, was used as the CE running buffer after injection of a single RPMC into the separation capillary to stimulate the release of the granules. Because the release process occurs on a ms time scale, monitoring individual exocytotic events is possible with the coupling of high-speed CE and LINF detection.

  17. Capillary condensation in porous alumina observed by positronium lifetime spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Eugeniu [National Institute for Nuclear Physics and Engineering-Horia Hulubei, Atomistilor Street 407, CP MG 06, Magurele, Bucharest (Romania); Center for Advanced Studies in Physics of the Roumanian Academy, Casa Academiei Romane, Calea 13 Septembrie No. 13, Bucharest (Romania); Vata, Ion [National Institute for Nuclear Physics and Engineering-Horia Hulubei, Atomistilor Street 407, CP MG 06, Magurele, Bucharest (Romania)], E-mail: vata@ifin.nipne.ro; Toderian, Stefan; Dudu, Dorin; Rusen, Ion; Stefan, Nitisor [National Institute for Nuclear Physics and Engineering-Horia Hulubei, Atomistilor Street 407, CP MG 06, Magurele, Bucharest (Romania)

    2008-10-31

    The PALS method based on time distribution measurements has been used to study capillary condensation of different gases adsorbed in microporous alumina powder. The isotherms exhibit features which are associated with a shifted gas-liquid transition. The sorption and desorption processes are irreversible presenting a hysteresis effect. Suggestions on some new aspects of the capillary condensation dynamics are made.

  18. Potential of capillary electrophoresis for the profiling of propolis

    NARCIS (Netherlands)

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    1998-01-01

    The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC) wit

  19. Fabrication of three-dimensional microstructures using capillary forces

    NARCIS (Netherlands)

    Honschoten, van J.W.; Berenschot, J.W.; Sanders, R.G.P.; Abelmann, L.; Tas, N.R.; Elwenspoek, M.

    2009-01-01

    In this paper we describe the fabrication of threedimensional microstructures by means of capillary forces. Using an origami-like technique, planar structures are folded to produce 3D-objects. To this purpose use is made of capillary interactions and surface tension forces. Capillarity is a particul

  20. Potential of capillary electrophoresis for the profiling of propolis

    NARCIS (Netherlands)

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    1998-01-01

    The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC)

  1. A Simple Double-Source Model for Interference of Capillaries

    Science.gov (United States)

    Hou, Zhibo; Zhao, Xiaohong; Xiao, Jinghua

    2012-01-01

    A simple but physically intuitive double-source model is proposed to explain the interferogram of a laser-capillary system, where two effective virtual sources are used to describe the rays reflected by and transmitted through the capillary. The locations of the two virtual sources are functions of the observing positions on the target screen. An…

  2. Capillary electrophoretic and mass spectrometric analysis of a polydisperse fluorosurfactant.

    Science.gov (United States)

    Al-Jarah, Suhair Yousif; Sjödahl, Johan; Woldegiorgis, Andreas; Emmer, Asa

    2005-02-01

    A fluorosurfactant has been studied using capillary electrophoresis and mass spectrometry. The fluorosurfactant, FC134, can be used as a buffer additive in capillary electrophoresis in order to decrease wall adsorption of proteins and in micellar electrokinetic chromatography. However, it has been discovered that this fluorosurfactant is polydisperse, thus containing substances with different lengths and structures. In this work, the fluorosurfactant sample components were separated by capillary electrophoresis. An uncoated as well as a poly(vinyl alcohol)-coated capillary were used with running electrolytes containing methanol and acetic acid. Following the capillary electrophoretic separation, fractions were collected for further analysis by MALDI-MS. Non-fractionated samples were also analyzed both by MALDI-MS and by ESI-MS.

  3. Fatal Primary Capillary Leak Syndrome in a Late Preterm Newborn.

    Science.gov (United States)

    Kulihova, Katarina; Prochazkova, Martina; Semberova, Jana; Janota, Jan

    2016-10-01

    Primary capillary leak syndrome is a rare disease of unknown etiology, characterized by episodes of vascular collapse and plasma extravasation, which may lead to multiple organ failure. Primary capillary leak is extremely rare in children. The authors report a case of a late preterm newborn with fatal capillary leak syndrome of unknown etiology, manifesting as hypotension unresponsive to treatment, extravasation leading to generalised edema, disseminated intravascular coagulation and finally, multiple organ dysfunction syndrome. Aggressive volumotherapy and a combination of inotropes and high doses of terlipressin did not influence systemic vascular collapse and plasma extravasation. The newborn developed multiple organ failure and died on day 27 of life. Investigations performed failed to reveal any specific cause of capillary leak. This is the first report of a fatal primary capillary leak syndrome in a newborn.

  4. Pore capillary pressure and saturation of methane hydrate bearing sediments

    Institute of Scientific and Technical Information of China (English)

    SUN Shicai; LIU Changling; YE Yuguang; LIU Yufeng

    2014-01-01

    To better understand the relationship between the pore capillary pressure and hydrate saturation in sedi-ments, a new method was proposed. First, the phase equilibria of methane hydrate in fine-grained silica sands were measured. As to the equilibrium data, the pore capillary pressure and saturation of methane hydrate were calculated. The results showed that the phase equilibria of methane hydrates in fine-grained silica sands changed due to the depressed activity of pore water caused by the surface group and negatively charged characteristic of silica particles as well as the capillary pressure in small pores together. The capil-lary pressure increased with the increase of methane hydrate saturation due to the decrease of the available pore space. However, the capillary-saturation relationship could not yet be described quantitatively because of the stochastic habit of hydrate growth.

  5. NRL capillary Z-pinch experiment

    Energy Technology Data Exchange (ETDEWEB)

    Sethian, J.D.; Gerber, K.A.; Robson, A.E. [Naval Research Lab., Washington, DC (United States); DeSilva, A.W. [Sachs/Freeman Associates, Inc., Landover, MD (United States)]|[Maryland Univ., College Park, MD (United States)

    1984-12-31

    The current renewed interest in the dense linear z-pinch is due in large part to a recent Los Alamos Study which concluded that a z- pinch based reactor could produce 4.4 KJ of fusion energy per pulse for the modest input of 140 kJ per pulse, if a straight pinch could be maintained for 2 {mu}sec. Early attempts to achieve suitable high density z-pinches were of the implosion type which produced hollow pressure profiles that quickly resulted in disruptive m = 0 instabilities. These instabilities are not found in the gas embedded pinch in which an initially small diameter plasma is kept in radial equilibrium by following a prescribed current waveform. Unfortunately, these pinches are prone to a rapid accretion of the surrounding gas during the early stages of formation. Our approach is to form the pinch inside small diameter quartz capillaries filled with neutral hydrogen. This fixes the line density. By driving currents through the pinch at a rate that exceeds that necessary for radial equilibrium, we expect the pinch to contract away from the walls and be subject to compressional, as well as ohmic heating. This contraction will, of course, produce a plasma between the pinch and the capillary wall, but we anticipate this ``corona`` will be kept at a low temperature (i.e., high resistance) by radiation and hence shunt only a small fraction of the pinch current. We also expect negligible impurities in the pinch as the classical mixing time will be much longer than the pinch duration at the densities (10{sup 21}- 10{sup 22} ions/cm{sup 3}) and magnetic fields (1 - 10 MG) involved. However, we do expect the presence of the dense corona to reduce the growth rate of the m = 1 instability. Our results demonstrate that a z-pinch can be formed inside a capillary, but our limited current rise rates and peak current have limited our test abilities. Planned improvements in electrical equipment should yield successful testing results.

  6. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian, Artaches A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Sanz Rodriguez, Estrella; Deverell, Jeremy A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); McCord, James; Muddiman, David C. [W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Paull, Brett, E-mail: Brett.Paull@utas.edu.au [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); ARC Centre of Excellence for Electromaterials Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia)

    2016-01-28

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L{sup −1} levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min{sup −1}, and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L{sup −1} for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%. - Highlights: • Novel PS-DVB modified photonic crystal fibres for in-capillary micro-extraction. • New method for micro-extraction of PAHs and HPLC-FL detection at sub-ppb levels. • Demonstration of PS-DVB modified photonic crystal fibres for capillary bioseparations.

  7. Determination of Amino Acids in Single Human Lymphocytes after On-capillary Derivatization by Capillary Zone Electrophoresis with Electrochemical Detection

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Amino acids in individual human lymphocytes were determined by capillary zone electrophoresis with electrochemical detection after on-capillary derivatization. In order to inject cells easily, a cell injector was designed. Four amino acids (serine, alanine, taurine, and glycine) in single human lymphocytes have been identified. Quantitation has been accomplished through the use of calibration curves.

  8. Double-layer poly(vinyl alcohol)-coated capillary for highly sensitive and stable capillary electrophoresis and capillary electrophoresis with mass spectrometry glycan analysis.

    Science.gov (United States)

    Zhang, Yi-Wei; Zhao, Ming-Zhe; Liu, Jing-Xin; Zhou, Ying-Lin; Zhang, Xin-Xiang

    2015-02-01

    Glycosylation plays an important role in protein conformations and functions as well as many biological activities. Capillary electrophoresis combined with various detection methods provided remarkable developments for high-sensitivity glycan profiling. The coating of the capillary is needed for highly polar molecules from complex biosamples. A poly(vinyl alcohol)-coated capillary is commonly utilized in the capillary electrophoresis separation of saccharides sample due to the high-hydrophilicity properties. A modified facile coating workflow was carried out to acquire a novel multiple-layer poly(vinyl alcohol)-coated capillary for highly sensitive and stable analysis of glycans. The migration time fluctuation was used as index in the optimization of layers and a double layer was finally chosen, considering both the effects and simplicity in fabrication. With migration time relative standard deviation less than 1% and theoretical plates kept stable during 100 consecutive separations, the method was presented to be suitable for the analysis of glycosylation with wide linear dynamic range and good reproducibility. The glycan profiling of enzymatically released N-glycans from human serum was obtained by the presented capillary electrophoresis method combined with mass spectrometry detection with acceptable results.

  9. Dynamic Stability of Equilibrium Capillary Drops

    Science.gov (United States)

    Feldman, William M.; Kim, Inwon C.

    2014-03-01

    We investigate a model for contact angle motion of quasi-static capillary drops resting on a horizontal plane. We prove global in time existence and long time behavior (convergence to equilibrium) in a class of star-shaped initial data for which we show that topological changes of drops can be ruled out for all times. Our result applies to any drop which is initially star-shaped with respect to a small ball inside the drop, given that the volume of the drop is sufficiently large. For the analysis, we combine geometric arguments based on the moving-plane type method with energy dissipation methods based on the formal gradient flow structure of the problem.

  10. Gravity-capillary free-surface flows

    CERN Document Server

    Vanden-Broeck, Jean-Marc

    2010-01-01

    Free surface problems occur in many aspects of science and of everyday life such as the waves on a beach, bubbles rising in a glass of champagne, melting ice, pouring flows from a container and sails billowing in the wind. Consequently, the effect of surface tension on gravity-capillary flows continues to be a fertile field of research in applied mathematics and engineering. Concentrating on applications arising from fluid dynamics, Vanden-Broeck draws upon his years of experience in the field to address the many challenges involved in attempting to describe such flows mathematically. Whilst careful numerical techniques are implemented to solve the basic equations, an emphasis is placed upon the reader developing a deep understanding of the structure of the resulting solutions. The author also reviews relevant concepts in fluid mechanics to help readers from other scientific fields who are interested in free boundary problems.

  11. Capillary electrophoresis of intact basic proteins using noncovalently triple-layer coated capillaries.

    Science.gov (United States)

    Haselberg, Rob; de Jong, Gerhardus J; Somsen, Govert W

    2009-07-01

    The usefulness of a noncovalent, positively charged capillary coating for the efficient analysis of intact basic proteins with CE was studied. Capillaries were coated by subsequent flushing with solutions of 10% w/v Polybrene (PB), 3% w/v dextran sulfate (DS), and again 10% w/v PB. Coating characterization studies showed that stable coatings could be produced which exhibited a pH-independent and highly reproducible EOF. The PB-DS-PB coating was evaluated with Tris phosphate BGEs of various pH using the four basic model proteins: alpha-chymotrypsinogen A, ribonuclease A, cytochrome c, and lysozyme. Typical migration time RSDs for the proteins were less than 0.85%, and apparent plate numbers were above 125,000 using a capillary length of 40 cm. The high separation efficiency allowed detection of several minor impurities in the model proteins. Using a BGE of medium pH, the CE system with triple-layer coating appeared to be useful for the repeatable profiling of recombinant humanized mouse monoclonal immunoglobulin G(1) showing a characteristic pattern of glycoforms. The CE system was also applied to the characterization of two llama antibodies, which were produced in Saccharomyces cerevisiae, revealing the presence of a side product in one of the antibodies. The high migration time stability allowed the reliable determination of antibody-antigen binding by monitoring migration time shifts. Finally, the feasibility of using the PB-DS-PB coated capillaries for CE with mass spectrometric detection was shown by the characterization of the impure llama antibody sample.

  12. Capillary electrophoresis-mass spectrometry using noncovalently coated capillaries for the analysis of biopharmaceuticals.

    Science.gov (United States)

    Haselberg, R; Brinks, V; Hawe, A; de Jong, G J; Somsen, G W

    2011-04-01

    In this work, the usefulness of capillary electrophoresis-electrospray ionization time-of-flight-mass spectrometry for the analysis of biopharmaceuticals was studied. Noncovalently bound capillary coatings consisting of Polybrene-poly(vinyl sulfonic acid) or Polybrene-dextran sulfate-Polybrene were used to minimize protein and peptide adsorption, and achieve good separation efficiencies. The potential of the capillary electrophoresis-mass spectrometry (CE-MS) system to characterize degradation products was investigated by analyzing samples of the drugs, recombinant human growth hormone (rhGH) and oxytocin, which had been subjected to prolonged storage, heat exposure, and/or different pH values. Modifications could be assigned based on accurate masses as obtained with time-of-flight-mass spectrometry (TOF-MS) and migration times with respect to the parent compound. For heat-exposed rhGH, oxidations, sulfonate formation, and deamidations were observed. Oxytocin showed strong deamidation (up to 40%) upon heat exposure at low pH, whereas at medium and high pH, mainly dimer (>10%) and trisulfide formation (6-7%) occurred. Recombinant human interferon-β-1a (rhIFN-β) was used to evaluate the capability of the CE-MS method to assess glycan heterogeneity of pharmaceutical proteins. Analysis of this N-glycosylated protein revealed a cluster of resolved peaks which appeared to be caused by at least ten glycoforms differing merely in sialic acid and hexose N-acetylhexosamine composition. Based on the relative peak area (assuming an equimolar response per glycoform), a quantitative profile could be derived with the disialytated biantennary glycoform as most abundant (52%). Such a profile may be useful for in-process and quality control of rhIFN-β batches. It is concluded that the separation power provided by combined capillary electrophoresis and TOF-MS allows discrimination of highly related protein species.

  13. Simultaneous measurements of capillary filtration and diffusion capacities during graded infusions of noradrenaline (NA) and 5-hydroxytryptamine (5-HT) into the rat hindquarter vascular bed.

    Science.gov (United States)

    Rippe, B; Folkow, B

    1980-07-01

    The relationships between capillary diffusion capacity (PS) for Cr-EDTA respective capillary filtration capacity (CFC) and vascular resistance during graded intraarterial infusions of NA and 5-HT into the artificially constant flow perfused rat hindquarter vascular bed were investigated. During maximal vasodilatation PS for Cr-EDTA was some 5.5--5.7 ml/min x 100 g, CFC some 0.04 ml/min x mmHg x 100 g, while vascular resistance was 2.8 mmHg x ml-1 x min x 100 g (PRU100) and isogravimetric capillary pressure 12.8 mmHg on an average. Setting out from maximal vasodilatation, increasing doses of NA and 5-HT produced graded reductions in capillary surface area as reflected by progressive decreases in both PS for Cr-EDTA and CFC. These changes occurred simultaneously with progressive increases in both pre- and postcapillary resistances, causing elevations in both arterial and capillary hydrostatic pressures and hance in capillary fluid filtration at constant flow. Capillary hydrostatic pressure increased maximally to 45 mmHg (calculated for NA) and vascular resistance to some 21 mmHg x ml-1 x min x 100 g on an average. PS for Cr-EDTA decreased maximally to some 0.7--1 ml/min x 100 g for both NA and 5-HT and furthermore, the relationships between PS for Cr-EDTA and PRU100 for NA respective 5-HT were almost identical. This was taken to indicate that capillary surface area for nutritional exchange is affected similarly by both drugs. However, the CFU-PRU100 relationship was shifted towards some 30--50% higher CFC values for 5-HT than for NA at almost every level of vasoconstriction. This might suggest that 5-HT besides reducing capillary surface area also induced moderate increases in capillary permeability though increases in number and/or radius of large pores (gaps) (cf. Rippe, Kamiya & Folkow 1978). Even during NA-induced vasoconstriction, when virtually no changes in capillary permeability occurred, PS for Cr-EDTA was reduced to a relatively greater extent than CFC, the

  14. A novel covalent coupling method for coating of capillaries with liposomes in capillary electrophoresis.

    Science.gov (United States)

    Mei, Jie; Xu, Jian-Rong; Xiao, Yu-Xiu; Liao, Xiao-Yan; Qiu, Guo-Fu; Feng, Yu-Qi

    2008-09-01

    A novel covalent coupling method for coating of capillaries with liposomes has been developed, which includes three steps: (i) epoxy-diol coating, (ii) activation with 2,2,2-trifluoroethanesulfonyl chloride, and (iii) liposome coupling. The coating conditions, such as the reaction time and temperature of liposome coupling, the content of dimyristoylphosphatidylethanolamine in liposomes, were optimized. Vesicles were visualized on the inner silica wall as confirmed by atomic force microscopy. The effectiveness of the coating was demonstrated by investigating the effect of pH of BGE on EOF and separating neutral compounds. The intra- and inter-capillary variations in EOF are 4.02% RSD (n=30) and 6.72% RSD (n=4) respectively, and the coated capillaries can be used to perform analysis at least for one month without any performance deterioration when stored at 4 degrees C. A set of drugs with diverse structures was applied into the developed liposome-coated CE. The normalized capacity factor (K) was introduced to quantitatively evaluate drug-membrane interactions. The relationship between log K and the fraction dose absorbed in humans (Fa%) shows that the liposome-coated CE can be utilized for in vitro prediction of Fa% of drugs that follow the transcellular passive transport route.

  15. Inhibition of 5-lipoxygenase and skin inflammation by the aerial parts of Artemisia capillaris and its constituents.

    Science.gov (United States)

    Kwon, Oh Song; Choi, Jae Sue; Islam, Md Nurul; Kim, Yeong Shik; Kim, Hyun Pyo

    2011-09-01

    The aerial parts of Artemisia capillaris Thunberg (Compositae) have been used in Chinese medicine as a liver protective agent, diuretic, and for amelioration of skin inflammatory conditions. This study was conducted to establish the scientific rationale for treating skin inflammation and to find active principles from A. capillaris. To accomplish these goals, the 70% ethanol extract of the aerial parts of A. capillaris (AR) was prepared and its 5-lipoxygenase (5-LOX) inhibitory action was studied since 5-LOX products are known to be involved in several allergic and skin inflammatory disorders. AR showed potent inhibitory activity against 5-LOX-catalyzed leukotriene production by ionophore-induced rat basophilic leukemia-1 cells, with an IC(50) of scopolin, scoparone, esculetin, quercetin, capillarisin, isorhamnetin, 3-O-robinobioside, isorhamnetin 3-O-galactoside and chlorogenic acid, were isolated from A. capillaris, and their effects were examined to identify the active principle(s). Several coumarin and flavonoid derivatives were found to be 5-LOX inhibitors. In particular, esculetin and quercetin were potent inhibitors, with IC(50) values of 6.6 and 0.7 μM, respectively. Against arachidonic acid-induced ear edema in mice, AR, and esculetin strongly inhibited edematic response. AR and esculetin also inhibited delayed-type hypersensitivity response in mice. In conclusion, AR and some of their major constituents are 5-LOX inhibitors, and these in vitro and in vivo activities may contribute to the therapeutic potential of AR in skin inflammatory disorders in traditional medicine.

  16. SKELETAL MUSCLE CAPILLARY FUNCTION: CONTEMPORARY OBSERVATIONS AND NOVEL HYPOTHESES

    Science.gov (United States)

    Poole, David C.; Copp, Steven W.; Ferguson, Scott K.; Musch, Timothy I.

    2014-01-01

    The capillary bed constitutes a vast surface facilitating exchange of O2, substrates and metabolites between blood and organs. In contracting skeletal muscle capillary blood flow and O2 diffusing capacity as well as O2 flux may increase two orders of magnitude above resting. Chronic diseases such as heart failure, diabetes and also sepsis impair these processes leading to compromised energetic, metabolic and ultimately contractile function. Among researchers seeking to understand blood-myocyte exchange in health and the bases for dysfunction in disease there is a fundamental disconnect between microcirculation specialists and many physiologists and physiologist clinicians. Whereas the former observe capillaries and capillary function directly (muscle intravital microscopy) the latter generally use indirect methodologies (e.g., post-mortem tissue analysis, 1-methyl xanthine, contrast enhanced ultrasound, permeability surface area product) and interpret their findings based upon August Krogh’s observations made nearly a century ago. “Kroghian” theory holds that only a small fraction of capillaries support red blood cell (RBC) flux in resting muscle leaving the vast majority to be “recruited” (i.e., initiate RBC flux) during contractions which would constitute the basis for increasing capillary exchange surface area and reducing capillary-mitochondrial diffusion distances. Experimental techniques each have their strengths and weaknesses and often the correct or complete answer to a problem emerges from integration across multiple technologies. Today Krogh’s entrenched “capillary recruitment” hypothesis is challenged by direct observations of capillaries in contracting muscle; something that he and his colleagues could not do. Moreover, in the peer-reviewed scientific literature, application of a range of contemporary physiological technologies including intravital microscopy of contracting muscle, magnetic resonance and near infrared spectroscopy and

  17. Capillary dynamics driven by molecular self-layering.

    Science.gov (United States)

    Wu, Pingkeng; Nikolov, Alex; Wasan, Darsh

    2017-02-10

    Capillary dynamics is a ubiquitous everyday phenomenon. It has practical applications in diverse fields, including ink-jet printing, lab-on-a-chip, biotechnology, and coating. Understanding capillary dynamics requires essential knowledge on the molecular level of how fluid molecules interact with a solid substrate (the wall). Recent studies conducted with the surface force apparatus (SFA), atomic force microscope (AFM), and statistical mechanics simulation revealed that molecules/nanoparticles confined into the film/wall surfaces tend to self-layer into 2D layer/s and even 2D in-layer with increased confinement and fluid volume fraction. Here, the capillary rise dynamics of simple molecular fluids in cylindrical capillary is explained by the molecular self-layering model. The proposed model considers the role of the molecular shape on self-layering and its effect on the molecularly thin film viscosity in regards to the advancing (dynamic) contact angle. The model was tested to explain the capillary rise dynamics of fluids of spherical, cylindrical, and disk shape molecules in borosilicate glass capillaries. The good agreement between the capillary rise data and SFA data from the literature for simple fluid self-layering shows the validity of the present model. The present model provides new insights into the design of many applications where dynamic wetting is important because it reveals the significant impact of molecular self-layering close to the wall on dynamic wetting.

  18. The effect of wettability on capillary fracturing in granular media

    Science.gov (United States)

    Trojer, M.; Szulczewski, M.; Juanes, R.

    2012-12-01

    During multiphase flow in a granular medium, capillary pressures can overcome cohesive forces between the grains and cause grain displacements that macroscopically resemble fracture patterns. These patterns were recently studied in experiments of air displacing water in a thin bed of glass beads, for which air is a strongly non-wetting fluid (Holtzman et al. 2012). The experiments showed that the transition from viscous fingering and capillary fingering to capillary fracturing could be predicted by a single dimensionless number called the fracturing number, which is the ratio of the capillary forces that promote grain displacements to the frictional forces that resist displacements. Here, we extend those experiments to study exclusively how the wettability of the invading fluid affects fracturing by visually observing the morphology of the pattern. As in the previous work, we inject a less viscous fluid into a thin bed of glass beads saturated with a more viscous fluid. However, we now vary the fluids to change the wettability of the invading fluid from perfectly non-wetting to wetting. We hypothesize that the emergence of fracturing can be predicted by a modified fracturing number that includes the contact angle to account for the effect of wettability on the capillary pressure. Since the contact angle is a function of the capillary number, we expect the emergence of fracturing will depend on the capillary number when the invading fluid is partially wetting.

  19. Converging of Argon Cluster Ion Beams with a Glass Capillary

    Science.gov (United States)

    Shoji, Kazuhiro; Iuchi, Kensuke; Izumi, Motoki; Moritani, Kousuke; Inui, Norio; Mochiji, Kozo

    We have investigated the converging behavior of argon gas cluster ion beam passed through a glass capillary. The gas cluster ions are attractive as a projectile for SIMS from the view point of minimization of the damages. The cluster ion beam of 5 keV consisting of 500˜3000 argon atoms was injected in the capillary. The inner diameters of the capillary at the inlet and outlet were 0.8 mm and 9.6˜140 μm, respectively. Ion current from the outlet of the all the capillaries were detected. We obtained the converging factor of 2˜7, which depended on the incident ion current. The kinetic energy of the incident ions was found to be reduced by 20˜30% by passing through the capillary. Contrary, the velocity of the ions was not changed. These facts suggest that the cluster becomes 20˜30% smaller in mass by passing through the capillary. As far as we know, this is the first report on the study of the converging of cluster ions by using a glass capillary.

  20. Trapped liquid drop at the end of capillary.

    Science.gov (United States)

    Wang, Zhengjia; Yen, Hung-Yu; Chang, Cheng-Chung; Sheng, Yu-Jane; Tsao, Heng-Kwong

    2013-10-01

    The liquid drop captured at the capillary end, which is observed in capillary valve and pendant drop technique, is investigated theoretically and experimentally. Because of contact line pinning of the lower meniscus, the lower contact angle is able to rise from the intrinsic contact angle (θ*) so that the external force acting on the drop can be balanced by the capillary force. In the absence of contact angle hysteresis (CAH), the upper contact angle remains at θ*. However, in the presence of CAH, the upper contact angle can descend to provide more capillary force. The coupling between the lower and upper contact angles determines the equilibrium shape of the captured drop. In a capillary valve, the pinned contact line can move across the edge as the pressure difference exceeds the valving pressure, which depends on the geometrical characteristic and wetting property of the valve opening. When CAH is considered, the valving pressure is elevated because the capillary force is enhanced by the receding contact angle. For a pendant drop under gravity, the maximal capillary force is achieved as the lower contact angle reaches 180° in the absence of CAH. However, in the presence of CAH, four regimes can be identified by three critical drop volumes. The lower contact angle can exceed 180°, and therefore the drop takes on the shape of a light bulb, which does not exist in the absence of CAH. The comparisons between Surface Evolver simulations and experiments are quite well.

  1. Capillary rise with velocity-dependent dynamic contact angle.

    Science.gov (United States)

    Popescu, M N; Ralston, J; Sedev, R

    2008-11-04

    The classic description of the rate of capillary rise given by the Washburn equation, which assumes that the contact angle preserves the equilibrium value at all times, has been recently questioned in the light of the known experimental dependence of the dynamic contact angle on the velocity of the contact line. For a number of such proposed functions of velocity for the dynamic contact angle, we analyze the resulting dependences of the contact angle and of the time of rise, respectively, on the height of the capillary rise. By applying our results to the particular cases of a high-viscosity silicone oil and water, respectively, in a glass capillary, we show that, in general, strong similarities arise between the various approaches and the classic theory in what concerns the time dependence of the capillary rise, which explains the lack of consistent experimental evidence for deviations in the rate of capillary rise from the Washburn equation. However, for a strong dependency of the contact angle on the velocity in the range of small velocities, as in the case of water on glass, one of the models predicts significant deviations even for the time dependence of the capillary rise. Moreover, our results show that the time or height dependence of the contact angle during the capillary rise can clearly discriminate between the various models.

  2. Capillary Contact Angle in a Completely Wet Groove

    Science.gov (United States)

    Parry, A. O.; Malijevský, A.; Rascón, C.

    2014-10-01

    We consider the phase equilibria of a fluid confined in a deep capillary groove of width L with identical side walls and a bottom made of a different material. All walls are completely wet by the liquid. Using density functional theory and interfacial models, we show that the meniscus separating liquid and gas phases at two phase capillary coexistence meets the bottom capped end of the groove at a capillary contact angle θcap(L) which depends on the difference between the Hamaker constants. If the bottom wall has a weaker wall-fluid attraction than the side walls, then θcap>0 even though all the isolated walls are themselves completely wet. This alters the capillary condensation transition which is now first order; this would be continuous in a capped capillary made wholly of either type of material. We show that the capillary contact angle θcap(L) vanishes in two limits, corresponding to different capillary wetting transitions. These occur as the width (i) becomes macroscopically large, and (ii) is reduced to a microscopic value determined by the difference in Hamaker constants. This second wetting transition is characterized by large scale fluctuations and essential critical singularities arising from marginal interfacial interactions.

  3. Liraglutide prevents microvascular insulin resistance and preserves muscle capillary density in high-fat diet-fed rats.

    Science.gov (United States)

    Chai, Weidong; Fu, Zhuo; Aylor, Kevin W; Barrett, Eugene J; Liu, Zhenqi

    2016-09-01

    Muscle microvasculature critically regulates endothelial exchange surface area to facilitate transendothelial delivery of insulin, nutrients, and oxygen to myocytes. Insulin resistance blunts insulin-mediated microvascular recruitment and decreases muscle capillary density; both contribute to lower microvascular blood volume. Glucagon-like peptide 1 (GLP-1) and its analogs are able to dilate blood vessels and stimulate endothelial cell proliferation. In this study, we aim to determine the effects of sustained stimulation of the GLP-1 receptors on insulin-mediated capillary recruitment and metabolic insulin responses, small arterial endothelial function, and muscle capillary density. Rats were fed a high-fat diet (HFD) for 4 wk with or without simultaneous administration of liraglutide and subjected to a euglycemic hyperinsulinemic clamp for 120 min after an overnight fast. Insulin-mediated muscle microvascular recruitment and muscle oxygenation were determined before and during insulin infusion. Muscle capillary density was determined and distal saphenous artery used for determination of endothelial function and insulin-mediated vasodilation. HFD induced muscle microvascular insulin resistance and small arterial vessel endothelial dysfunction and decreased muscle capillary density. Simultaneous treatment of HFD-fed rats with liraglutide prevented all of these changes and improved insulin-stimulated glucose disposal. These were associated with a significantly increased AMPK phosphorylation and the expressions of VEGF and its receptors. We conclude that GLP-1 receptor agonists may exert their salutary glycemic effect via improving microvascular insulin sensitivity and muscle capillary density during the development of insulin resistance, and early use of GLP-1 receptor agonists may attenuate metabolic insulin resistance as well as prevent cardiovascular complications of diabetes. Copyright © 2016 the American Physiological Society.

  4. Microstructural control over soluble pentacene deposited by capillary pen printing for organic electronics.

    Science.gov (United States)

    Lee, Wi Hyoung; Min, Honggi; Park, Namwoo; Lee, Junghwi; Seo, Eunsuk; Kang, Boseok; Cho, Kilwon; Lee, Hwa Sung

    2013-08-28

    Research into printing techniques has received special attention for the commercialization of cost-efficient organic electronics. Here, we have developed a capillary pen printing technique to realize a large-area pattern array of organic transistors and systematically investigated self-organization behavior of printed soluble organic semiconductor ink. The capillary pen-printed deposits of organic semiconductor, 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS_PEN), was well-optimized in terms of morphological and microstructural properties by using ink with mixed solvents of chlorobenzene (CB) and 1,2-dichlorobenzene (DCB). Especially, a 1:1 solvent ratio results in the best transistor performances. This result is attributed to the unique evaporation characteristics of the TIPS_PEN deposits where fast evaporation of CB induces a morphological evolution at the initial printed position, and the remaining DCB with slow evaporation rate offers a favorable crystal evolution at the pinned position. Finally, a large-area transistor array was facilely fabricated by drawing organic electrodes and active layers with a versatile capillary pen. Our approach provides an efficient printing technique for fabricating large-area arrays of organic electronics and further suggests a methodology to enhance their performances by microstructural control of the printed organic semiconducting deposits.

  5. On-column micro gas chromatography detection with capillary-based optical ring resonators.

    Science.gov (United States)

    Shopova, Siyka I; White, Ian M; Sun, Yuze; Zhu, Hongying; Fan, Xudong; Frye-Mason, Greg; Thompson, Aaron; Ja, Shiou-jyh

    2008-03-15

    We developed a novel on-column micro gas chromatography (microGC) detector using capillary based optical ring resonators (CBORRs). The CBORR is a thin-walled fused silica capillary with an inner diameter ranging from a few tens to a few hundreds of micrometers. The interior surface of the CBORR is coated with a layer of stationary phase for gas separation. The circular cross section of the CBORR forms a ring resonator and supports whispering gallery modes (WGMs) that circulate along the ring resonator circumference hundreds of times. The evanescent field extends into the core and is sensitive to the refractive index change induced by the interaction between the gas sample and the stationary phase. The WGM can be excited and monitored at any location along the CBORR by placing a tapered optical fiber against the CBORR, thus enabling on-column real-time detection. Rapid separation of both polar and nonpolar samples was demonstrated with subsecond detection speed. Theoretical work was also established to explain the CBORR detection mechanism. While low-nanogram detection limits are observed in these preliminary tests, many methods for improvements are under investigation. The CBORR is directly compatible with traditional capillary GC columns without any dead volumes. Therefore, the CBORR-based muGC is a very promising technology platform for rapid, sensitive, and portable analytical devices.

  6. Near-surface viscosity effects on capillary rise of water in nanotubes

    Science.gov (United States)

    Vo, Truong Quoc; Barisik, Murat; Kim, BoHung

    2015-11-01

    In this paper, we present an approach for predicting nanoscale capillary imbibitions using the Lucas-Washburn (LW) theory. Molecular dynamics (MD) simulations were employed to investigate the effects of surface forces on the viscosity of liquid water. This provides an update to the modified LW equation that considered only a nanoscale slip length. An initial water nanodroplet study was performed to properly elucidate the wetting behavior of copper and gold surfaces. Intermolecular interaction strengths between water and corresponding solid surfaces were determined by matching the contact angle values obtained by experimental measurements. The migration of liquid water into copper and gold capillaries was measured by MD simulations and was found to differ from the modified LW equation. We found that the liquid layering in the vicinity of the solid surface induces a higher density and viscosity, leading to a slower MD uptake of fluid into the capillaries than was theoretically predicted. The near-surface viscosity for the nanoscale-confined water was defined and calculated for the thin film of water that was sheared between the two solid surfaces, as the ratio of water shear stress to the applied shear rate. Considering the effects of both the interface viscosity and slip length of the fluid, we successfully predicted the MD-measured fluid rise in the nanotubes.

  7. Distribution of anionic sites on the capillary endothelium in an experimental brain tumor model.

    Science.gov (United States)

    Vincent, S; DePace, D; Finkelstein, S

    1988-02-01

    The distribution of anionic domains on the capillary endothelium of experimental brain tumors was determined using cationic ferritin (CF) in order to ascertain whether the pattern of these domains is different from that on normal cerebral capillaries. Tumors were induced by stereotaxic injection of cultured neoplastic glial cells, A15A5, into the caudate nucleus of Sprague-Dawley rats. Following a 14-21 day growth period tumors appeared as vascularized, sharply circumscribed masses which caused compression of the surrounding brain tissue. Anionic domains were distributed in a patchy and irregular pattern on the luminal plasma membrane of the endothelia of blood vessels in the tumors. Some variability in this pattern was observed infrequently in limited regions of the tumor where there was either a continuous layer of CF or an absence of CF binding. Plasmalemmal vesicles, coated vesicles, coated pits, multivesicular bodies, and some junctional complexes showed varying degrees of labeling with the probe. Capillaries in the tumor periphery and normal cerebral vessels showed a uniform distribution of anionic groups. These results indicate that there is an altered surface charge on the endothelial luminal plasma membrane of blood vessels in brain tumors. A correlation may exist between the altered surface charge and the degree to which the blood-brain barrier is impaired in these vessels.

  8. Developmental venous anomalies with capillary stain: a subgroup of symptomatic DVAs?

    Energy Technology Data Exchange (ETDEWEB)

    Roccatagliata, Luca [Hopital Foch, Service de Neuroradiologie Diagnostique et Therapeutique, Suresnes (France); University of Genoa, Department of Neurosciences, Ophthalmology and Genetics, Genoa (Italy); Berg, Rene van den [AMC, Department of Radiology, Amsterdam (Netherlands); Soderman, Michael [Karolinska University Hospital, Department of Neuroradiology, Stockholm (Sweden); Boulin, Anne; Condette-Auliac, Stephanie; Rodesch, Georges [Hopital Foch, Service de Neuroradiologie Diagnostique et Therapeutique, Suresnes (France)

    2012-05-15

    Intracranial developmental venous anomalies (DVAs) are considered benign vascular dispositions; they are asymptomatic in the vast majority of cases. They represent extreme variations of the venous drainage and may rarely be responsible for focal venous ischemia leading to neurological dysfunction. The aim of the study is to analyze a group of patients with symptomatic DVAs with capillary stain at angiography. We retrospectively reviewed the clinical and radiological features of patients in which a DVA was considered the cause of a neurological event. In all the patients, the DVA was suspected by angio-CT or MRI and conventional angiography was performed to detail the angioarchitecture of the DVA. A total of 7 patients and 11 DVAs were identified; three patients had multiple DVAs. Three DVAs were frontal, two were parietal, two were thalamic, one was in the midbrain, and three were cerebellar. Patients presented with progressive neurological deficits, seizures, or cerebral hemorrhage. All these DVAs were associated with a peculiar capillary stain at angiography. Although being normal anatomical variations, DVAs may create, because of hemodynamic unbalance, venous ischemia that induces angiogenic phenomena. MRI shows the suffering of the brain and angiography witnesses this angiogenesis under the form of capillary stain. Conventional angiography can thus provide useful information to recognize ''atypical'' symptomatic DVAs. (orig.)

  9. Determination of endogenous ions in intercellular fluid using capillary ultrafiltration and microdialysis probes.

    Science.gov (United States)

    Linhares, M C; Kissinger, P T

    1993-01-01

    Capillary ultrafiltration probes are novel sampling tools for continuously monitoring small molecules in the extracellular fluid of awake animals. Capillary ultrafiltration uses a vacuum applied to hydrophilic membrane fibres and extracts intercellular fluid and quantitatively recover many small hydrophilic molecules. The effects of continuously removing a small amount of fluid from the interstitial space are not known. The concentration of sodium, potassium, calcium and inorganic phosphorus were determined in the collected ultrafiltrates from subcutaneous tissue. These values were compared to literature values and to concentrations determined for the same animals using microdialysis. The concentrations of sodium, potassium, calcium and inorganic phosphorous were found to be 140 +/- 4, 3.7 +/- 0.1, 1.1 +/- 0.1 and 1.7 +/- 0.1 mM, respectively, in the subcutaneous ultrafiltrates obtained from rats. These corresponded very well with literature values and microdialysates, obtained, using pure water as the perfusate, in subcutaneous tissue. The concentration of sodium and potassium were determined to be 142 +/- 2 mM and 3.6 +/- 0.2 mM, respectively, for the dialysates. Hyperinsulinemic-induced decrease in intercellular potassium levels under a euglycemic clamp were monitored using capillary ultrafiltration probes in rats to further validate this technique for monitoring small molecule dynamics in the intercellular space. The intercellular level of potassium in rats decreased from 3.6 +/- 0.5 to 2.6 +/- 0.3 mM after an acute dose of pork insulin.

  10. Development of Capillary Loop Convective Polymerase Chain Reaction Platform with Real-Time Fluorescence Detection

    Directory of Open Access Journals (Sweden)

    Wen-Pin Chou

    2017-02-01

    Full Text Available Polymerase chain reaction (PCR has been one of the principal techniques of molecular biology and diagnosis for decades. Conventional PCR platforms, which work by rapidly heating and cooling the whole vessel, need complicated hardware designs, and cause energy waste and high cost. On the other hand, partial heating on the various locations of vessels to induce convective solution flows by buoyancy have been used for DNA amplification in recent years. In this research, we develop a new convective PCR platform, capillary loop convective polymerase chain reaction (clcPCR, which can generate one direction flow and make the PCR reaction more stable. The U-shaped loop capillaries with 1.6 mm inner diameter are designed as PCR reagent containers. The clcPCR platform utilizes one isothermal heater for heating the bottom of the loop capillary and a CCD device for detecting real-time amplifying fluorescence signals. The stable flow was generated in the U-shaped container and the amplification process could be finished in 25 min. Our experiments with different initial concentrations of DNA templates demonstrate that clcPCR can be applied for precise quantification. Multiple sample testing and real-time quantification will be achieved in future studies.

  11. Capillary electrophoresis methods for microRNAs assays: A review

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Eunmi; Song, Eun Joo, E-mail: ejsong@kist.re.kr

    2014-12-10

    Highlights: • A review of CE analysis of miRNAs. • Summary of developments and applications of CE systems in miRNA studies. • Applications and development of microchip-based CE for rapid analysis of miRNA. - Abstract: MicroRNAs (miRNAs) are short noncoding RNAs that conduct important roles in many cellular processes such as development, proliferation, differentiation, and apoptosis. In particular, circulating miRNAs have been proposed as biomarkers for cancer, diabetes, cardiovascular disease, and other illnesses. Therefore, determination of miRNA expression levels in various biofluids is important for the investigation of biological processes in health and disease and for discovering their potential as new biomarkers and drug targets. Capillary electrophoresis (CE) is emerging as a useful analytical tool for analyzing miRNA because of its simple sample preparation steps and efficient resolution of a diverse size range of compounds. In particular, CE with laser-induced fluorescence detection is a promising and relatively rapidly developing tool with the potential to provide high sensitivity and specificity in the analysis of miRNAs. This paper covers a short overview of the recent developments and applications of CE systems in miRNA studies in biological and biomedical areas.

  12. Capillary Origami Inspired Fabrication of Complex 3D Hydrogel Constructs.

    Science.gov (United States)

    Li, Moxiao; Yang, Qingzhen; Liu, Hao; Qiu, Mushu; Lu, Tian Jian; Xu, Feng

    2016-09-01

    Hydrogels have found broad applications in various engineering and biomedical fields, where the shape and size of hydrogels can profoundly influence their functions. Although numerous methods have been developed to tailor 3D hydrogel structures, it is still challenging to fabricate complex 3D hydrogel constructs. Inspired by the capillary origami phenomenon where surface tension of a droplet on an elastic membrane can induce spontaneous folding of the membrane into 3D structures along with droplet evaporation, a facile strategy is established for the fabrication of complex 3D hydrogel constructs with programmable shapes and sizes by crosslinking hydrogels during the folding process. A mathematical model is further proposed to predict the temporal structure evolution of the folded 3D hydrogel constructs. Using this model, precise control is achieved over the 3D shapes (e.g., pyramid, pentahedron, and cube) and sizes (ranging from hundreds of micrometers to millimeters) through tuning membrane shape, dimensionless parameter of the process (elastocapillary number Ce ), and evaporation time. This work would be favorable to multiple areas, such as flexible electronics, tissue regeneration, and drug delivery.

  13. Demonstration of a high repetition rate capillary discharge waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Gonsalves, A. J., E-mail: ajgonsalves@lbl.gov; Pieronek, C.; Daniels, J.; Bulanov, S. S.; Waldron, W. L.; Mittelberger, D. E.; Leemans, W. P. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Liu, F.; Antipov, S.; Butler, J. E. [Euclid TechLabs, Gaithersburg, Maryland 20879 (United States); Bobrova, N. A.; Sasorov, P. V. [Keldysh Institute of Applied Mathematics, Moscow (Russian Federation)

    2016-01-21

    A hydrogen-filled capillary discharge waveguide operating at kHz repetition rates is presented for parameters relevant to laser plasma acceleration (LPA). The discharge current pulse was optimized for erosion mitigation with laser guiding experiments and MHD simulation. Heat flow simulations and measurements showed modest temperature rise at the capillary wall due to the average heat load at kHz repetition rates with water-cooled capillaries, which is promising for applications of LPAs such as high average power radiation sources.

  14. Corrugated capillary as THz Cherenkov Smith-Purcell radiator

    Science.gov (United States)

    Lekomtsev, K. V.; Aryshev, A. S.; Tishchenko, A. A.; Ponomarenko, A. A.; Sukharev, V. M.; Terunuma, N.; Urakawa, J.; Strikhanov, M. N.

    2016-07-01

    In this article we discussed Particle In Cell electromagnetic simulations and mechanical design of dielectric capillaries that produce THz Cherenkov Smith-Purcell radiation (ChSPR), arising when a femtosecond electron multi-bunch beam propagates through corrugated and non-corrugated dielectric capillaries with metallic radiation reflectors. We investigated the influence of the four-bunch beam on the SPR field spectrum and on the ChSPR power spectrum, and the influence of the non-central beam propagation on the ChSPR power spectrum. We also discussed the design and assembly of the capillaries, constructed as sets of cylindrical rings.

  15. [Capillary hemangioma of the spinal cord: case report].

    Science.gov (United States)

    Holanda, Maurus Marques de Almeida; Sarmento, Stênio Abrantes; Andrade, Rodrigo Vasconcelos Correia Lima de; Nóbrega, Evaldo de Sousa; Silva, José Alberto Gonçalves da

    2004-06-01

    We report a rare case of spinal cord capillary hemangioma in a 79-year-old woman, presented with paraparesia that had progressed within 8 months. Radiologically, the lesion resemble other vascular spinal cord tumors. The patient underwent surgery and the outcome was good. Histologically, the lesion resembled capillary hemangioma of skin or soft tissue, composed of lobules of small capillaries with associated feeding vessels, all enveloped by a delicate fibrous capsule. A review of the published cases in the literature is provided as well as a discussion of the clinical, radiological and histological aspects of the lesion and the differential diagnosis. Knowledge of its existence may avoid misdiagnosis of this benign lesion.

  16. Plasma Acceleration from RF Discharge in Dielectric Capillary

    Energy Technology Data Exchange (ETDEWEB)

    A. Dunaevsky; Y. Raitses; N. J. Fisch

    2005-08-09

    Plasma acceleration from rf discharge in dielectric capillary was demonstrated. Observed plasma flow had ion energies of approximately 100 eV and electron energies of approximately 20 eV. The discharge was powered by a MHz-range rf generator and fed by Ar. Experimental results indicate possible validity of assumptions about formation of a potential difference at the open end of the capillary and presence of hot electron fraction in the capillary discharge. Simplicity and small dimensions of the source are attractive for micro-propulsion applications.

  17. Capillary-Driven Flow in Liquid Filaments Connecting Orthogonal Channels

    Science.gov (United States)

    Allen, Jeffrey S.

    2005-01-01

    Capillary phenomena plays an important role in the management of product water in PEM fuel cells because of the length scales associated with the porous layers and the gas flow channels. The distribution of liquid water within the network of gas flow channels can be dramatically altered by capillary flow. We experimentally demonstrate the rapid movement of significant volumes of liquid via capillarity through thin liquid films which connect orthogonal channels. The microfluidic experiments discussed provide a good benchmark against which the proper modeling of capillarity by computational models may be tested. The effect of surface wettability, as expressed through the contact angle, on capillary flow will also be discussed.

  18. Separation and quantification of cellulases and hemicellulases by capillary electrophoresis

    DEFF Research Database (Denmark)

    Jørgensen, Henning; Kutter, Jörg Peter; Olsson, Lisbeth

    2003-01-01

    . Current methods are limited in their ability to quantify all of these enzymes when all are present simultaneously in a mixture. Five different cellulases (two cellobiohydrolases and three endoglucanases) and one hemicellulase (endoxylanase) were separated using capillary electrophoresis (CE) in a fused...... silica capillary at pH values close to neutral. The improvement of the separation of these six proteins by the addition of alpha, omega-diaminoalkanes with chain lengths from three to seven carbon units was investigated. Dynamically coating the capillary with 1,3-diaminopropane resulted in separation...

  19. Abnormalities in three-dimensional capillary architecture and imbalance between vascular endothelial growth factor-A and thrombospondin-1 in soleus muscle of ovariectomized rat.

    Science.gov (United States)

    Tanaka, Masayuki; Kanazashi, Miho; Maezawa, Toshiyuki; Kondo, Hiroyo; Fujino, Hidemi

    2015-09-01

    Reduced ovarian hormone levels associated with menopause or ovariectomy (OVX) not only result in vascular dysfunction but also lead to structural abnormalities in capillaries. Therefore, the effect of OVX on the three-dimensional (3-D) architecture of capillary networks and the underlying molecular mechanisms were investigated in rat soleus muscle. Seven-week-old female Wistar rats were divided into the OVX and sham-treated (Sham) groups. The OVX group exhibited lower endurance exercise capacity compared to the sham group and resulted in decreased capillary diameter, number of anastomoses and capillary/anastomosis volume in soleus muscle, indicating 3-D structural abnormalities of capillary networks. Furthermore, OVX led to increased concentrations of thrombospondin-1 (TSP-1) protein and a decreased VEGF-A/TSP-1 ratio, an indicator of angio-adaptations, in soleus muscle compared with the Sham group. These results indicate OVX may induce 3-D capillary regression in soleus muscle through an imbalance between VEGF-A and TSP-1 expression, possibly associated with decreased exercise tolerance in ovariectomized rats.

  20. Reactive oxygen species inactivation improves pancreatic capillary blood flow in caerulein-induced pancreatitis in rats A inativação de radicais livres melhora o fluxo capilar pancreático em pancreatite aguda induzida por ceruleína em ratos

    Directory of Open Access Journals (Sweden)

    Roberto Ferreira Meirelles Jr.

    2003-01-01

    Full Text Available PURPOSE: Reactive oxygen species (ROS inactivation was studied to determine alterations in the pancreatic capillary blood flow (PCBF during caerulein-induced pancreatitis in rats. METHODS: A laser-Doppler flowmeter to measure PCBF and N-t-Butyl-Phenylnitrone (PBN compound to inactivate ROS were used. Forty rats were divided in groups: 1 control; 2 caerulein; 3 PBN; 4 caerulein+PBN. Serum biochemistry and histopathological analyses were performed. RESULTS: PCBF measured a mean of 109.08 ± 14.54%, 68.24 ± 10.47%, 102.18 ± 10.23% and 87.73 ± 18.72% in groups 1, 2, 3 and 4, respectively. PCBF in groups 2 and 4 decreased 31.75 ± 16.79% and 12.26 ± 15.24%, respectively. Serum amylase was 1323.70 ± 239.10 U/l, 2184.60 ± 700.46 U/l, 1379.80 ± 265.72 U/l and 1622.10 ± 314.60 U/l in groups 1, 2, 3 and 4, respectively. There was a significant difference in the PCBF and serum amylase when compared groups 2 and 4. Cytoplasmatic vacuolation was present in groups 2 and 4. Otherwise, no qualitative changes were seen. CONCLUSION: ROS inactivation improves PCBF and minimizes the serum amylase increase during caerulein-induced pancreatitis. ROS effect may be one of the leading causative events in this model of acute pancreatitis.OBJETIVO: A inativação de radicais livres (RL foi estudada para determinar as alterações do fluxo capilar pancreático (FCP na pancreatite aguda induzida por ceruleína em ratos. MÉTODOS: Um laser-Doppler fluxímetro determinou o FCP e o composto N-t-Butyl-Phenylnitrone (PBN, para inativar os RL, foi utilizado. Quarenta ratos foram divididos em 4 grupos: 1 controle; 2ceruleína; 3 PBN; 4ceruleína+PBN. Dosagens bioquímicas e análise histopatológica foram realizadas. RESULTADOS: O FCP foi em média 109.08 ± 14.54%, 68.24 ± 10.47%, 102.18 ± 10.23% e 87.73 ± 18.72% nos grupos 1, 2, 3 and 4, respectivamente. O FCP nos grupos 2 e 4 diminuíram em média 31.75 ± 16.79% e 12.26 ± 15.24%, respectivamente. A média da

  1. Lactate dilates cochlear capillaries via type V fibrocyte-vessel coupling signaled by nNOS.

    Science.gov (United States)

    Dai, Min; Yang, Yue; Shi, Xiaorui

    2011-10-01

    Transduction of sound in the inner ear demands tight control over delivery of oxygen and glucose. However, the mechanisms underlying the control of regional blood flow are not yet fully understood. In this study, we report a novel local control mechanism that regulates cochlear blood flow to the stria vascularis, a high energy-consuming region of the inner ear. We found that extracellular lactate had a vasodilatory effect on the capillaries of the spiral ligament under both in vitro and in vivo conditions. The lactate, acting through monocarboxylate transporter 1 (MCT1), initiated neuronal nitric oxide (NO) synthase (nNOS) and catalyzed production of NO for the vasodilation. Blocking MCT1 with the MCT blocker, α-cyano-4-hydroxycinnamate (CHC), or a suppressing NO production with either the nonspecific inhibitor of NO synthase, N(G)-nitro-L-arginine methyl ester (L-NAME), or either of two selective nNOS inhibitors, 3-bromo-7-nitroindazole or (4S)-N-(4-amino-5[aminoethyl]aminopentyl)-N'-nitroguanidine (TFA), totally abolished the lactate-induced vasodilation. Pretreatment with the selective endothelial NO synthase inhibitor, L-N(5)-(1-iminoethyl)ornithine (L-NIO), eliminated the inhibition of lactate-induced vessel dilation. With immunohistochemical labeling, we found the expression of MCT1 and nNOS in capillary-coupled type V fibrocytes. The data suggest that type V fibrocytes are the source of the lactate-induced NO. Cochlear microvessel tone, regulated by lactate, is mediated by an NO-signaled coupling of fibrocytes and capillaries.

  2. [Immature palpebral capillary angioma. A case commented on].

    Science.gov (United States)

    Robin, H; Hurbli, T; Morax, S

    1994-01-01

    A three-year-old girl presented a voluminous capillary haemangioma associated with amblyopia. This case failed to respond to steroid treatment. Surgical treatment was necessary. The authors describe evolution, complications and therapeutic management of eyelid angiodysplasia.

  3. Optimization of a Water Window Capillary Discharge Radiation Source

    Directory of Open Access Journals (Sweden)

    M. Stefanovič

    2011-01-01

    Full Text Available Computer modeling of a fast electrical discharge in a nitrogen-filled alumina capillary was performed in order to discover discharge system parameters that lead to high radiation intensity in the so-called water window range of wavelengths (2–4 nm. The modeling was performed by means of the two-dimensional RMHD code Z*. The time and spatial distribution of plasma quantities were used for calculating the ion level populations and for estimating the absorption of the 2.88 nm radiation line in the capillary plasma, using the FLYCHK code. Optimum discharge parameters for the capillary discharge water window source are suggested. The heating of the electrodes and the role of capillary channel shielding were analyzed according to the Z* code.

  4. (Wormwood capillary) by random amplified polymorphic DNA (RAPD)

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-04

    May 4, 2009 ... fragments (100%) with size ranging from 150 – 3000 bp were scored from the population. Genetic distance for ... Artemisia capillaris is a species from class Magnoliopsida ... Japan, Taiwan (ShamShop.net, 2002) and to some.

  5. High Performance Wafer-Based Capillary Electrochromatography Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research proposes to develop wafer-based capillary electrochromatography for lab-on-a-chip (LOC) applications. These microfluidic devices will be...

  6. Targeted Functionalization of Nanoparticle Thin Films via Capillary Condensation

    KAUST Repository

    Gemici, Zekeriyya

    2009-03-11

    Capillary condensation, an often undesired natural phenomenon in nanoporous materials, was used advantageously as a universal functionalization strategy in nanoparticle thin films assembled layer-by-layer. Judicious choice of nanoparticle (and therefore pore) size allowed targeted capillary condensation of chemical vapors of both hydrophilic and hydrophobic molecules across film thickness. Heterostructured thin films with modulated refractive index profiles produced in this manner exhibited broadband antireflection properties with an average reflectance over the visible region of the spectrum of only 0.4%. Capillary condensation was also used to modify surface chemistry and surface energy. Photosensitive capillary-condensates were UV-cross-linked in situ. Undesired adventitious condensation of humidity could be avoided by condensation of hydrophobic materials such as poly(dimethyl siloxane). © 2009 American Chemical Society.

  7. Carbon nanotube patterning with capillary micromolding of catalyst.

    Science.gov (United States)

    Lee, Jaewon; Ryu, Choonghan; Lee, Sungwoo; Jung, Donggeun; Kim, Hyoungsub; Chae, Heeyeop

    2007-11-01

    Patterning of multi-walled carbon nanotube (MWNT) in a plasma enhanced chemical vapor deposition (PECVD) chamber has been achieved by catalyst patterning using capillary micromolding process. Iron acetate catalyst nanoparticles were dissolved in ethanol and mold was fabricated with polydimethylsiloxane (PDMS). The ethanol solution containing catalyst nanoparticles was filled into the microchannel formed between PDMS mold and Si-wafer by capillary force. The capillary action of different solvents was simulated by commercial CFD-ACE+ simulation code to determine optimal solvents. Simulated result shows that the choice of solvent was critical in this capillary filling process. After the catalyst patterning, MWNT was grown at 700 approximately 800 degrees C by PECVD process using CH4 and Ar gas in a scale of approximately 10 micro-meters in a tubular inductively coupled plasma reactor. Grown CNTs were analyzed by FE-SEM and Raman Spectroscopy.

  8. Improved Refrigerant Characteristics Flow Predictions in Adiabatic Capillary Tube

    Directory of Open Access Journals (Sweden)

    Shodiya Sulaimon

    2012-07-01

    Full Text Available This study presents improved refrigerant characteristics flow predictions using homogenous flow model in adiabatic capillary tube, used in small vapor compression refrigeration system. The model is based on fundamental equations of mass, momentum and energy. In order to improve the flow predictions, the inception of vaporization in the capillary tube is determined by evaluating initial vapor quality using enthalpy equation of refrigerant at saturation point and the inlet entrance effect of the capillary tube is also accounted for. Comparing this model with experimental data from open literature showed a reasonable agreement. Further comparison of this new model with earlier model of Bansal showed that the present model could be use to improve the performance predictions of refrigerant flow in adiabatic capillary tube.

  9. Aggregation of frictional particles due to capillary attraction

    CERN Document Server

    Dalbe, Marie-Julie; Berhanu, Michael; Kudrolli, Arshad

    2011-01-01

    Capillary attraction between identical millimeter sized spheres floating at a liquid-air interface and the resulting aggregation is investigated at low Reynolds number. We show that the measured capillary forces between two spheres as a function of distance can be described by expressions obtained using the Nicolson approximation at low Bond numbers for far greater particle sizes than previously assumed. We find that viscous hydrodynamics interactions between the spheres needs to be included to describe the dynamics close to contact. We then consider the aggregates formed when a third sphere is added after the initial two spheres are already in contact. In this case, we find that linear superposition of capillary forces describes the observed approach qualitatively but not quantitatively. Further, we observe an angular dependence of the structure due to a rapid decrease of capillary force with distance of separation which has a tendency to align the particles before contact. When the three particles come in c...

  10. Capillary Array Waveguide Amplified Fluorescence Detector for mHealth.

    Science.gov (United States)

    Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham

    2013-09-01

    Mobile Health (mHealth) analytical technologies are potentially useful for carrying out modern medical diagnostics in resource-poor settings. Effective mHealth devices for underserved populations need to be simple, low cost, and portable. Although cell phone cameras have been used for biodetection, their sensitivity is a limiting factor because currently it is too low to be effective for many mHealth applications, which depend on detection of weak fluorescent signals. To improve the sensitivity of portable phones, a capillary tube array was developed to amplify fluorescence signals using their waveguide properties. An array configured with 36 capillary tubes was demonstrated to have a ~100X increase in sensitivity, lowering the limit of detection (LOD) of mobile phones from 1000 nM to 10 nM for fluorescein. To confirm that the amplification was due to waveguide behavior, we coated the external surfaces of the capillaries with silver. The silver coating interfered with the waveguide behavior and diminished the fluorescence signal, thereby proving that the waveguide behavior was the main mechanism for enhancing optical sensitivity. The optical configuration described here is novel in several ways. First, the use of capillaries waveguide properties to improve detection of weak florescence signal is new. Second we describe here a three dimensional illumination system, while conventional angular laser waveguide illumination is spot (or line), which is functionally one-dimensional illumination, can illuminate only a single capillary or a single column (when a line generator is used) of capillaries and thus inherently limits the multiplexing capability of detection. The planar illumination demonstrated in this work enables illumination of a two dimensional capillary array (e.g. x columns and y rows of capillaries). In addition, the waveguide light propagation via the capillary wall provides a third dimension for illumination along the axis of the capillaries. Such an

  11. Capillary discharge extreme ultraviolet lasers. [Colorado State Univ. , Ft. Collins

    Energy Technology Data Exchange (ETDEWEB)

    Rocca, J.J.

    1992-08-01

    The project objective is to explore the generation of soft X-ray laser radiation in a plasma column created by a fast capillary discharge. The proposed capillary lasing scheme offers the potential for compact, simple and efficient soft X-ray laser sources. For this purpose a compact, fast pulse generator which produces 100 kA current pulses with a risetime of 11 ns was constructed. Initial experiments were conducted in evacuated capillaries, in which the plasma is produced by ablation of the capillary walls. The soft X-ray emission from discharges in polyethylene capillary channels was studied to investigate the possibility of amplification in the 3-2 transition of C VI, at {lambda} = 18.2 nm. Time-resolved spectra in which this transition appears anomalously intense with respect to the 4--2 transition of the same ion were obtained. To date, however, this phenomenoa could not be confirmed as gain, as the intensity of the 18.2 nm line has not been observed to increase exponentially as a function of the capillary length. Encouraging results were obtained by fast pulse discharge excitation of capillaries filled with preionized gas. High temperature (Te > 150 eV), small diameter ({approximately}200 {mu}m) plasma columns were efficiently generated. Fast current pulse excitation of a selected low mass density of uniformly preionized material Mag the capillary was observed to detach rapidly the plasma from the capillary walls, and form a plasma channel of a diameter much smaller and significantly hotter than those produced by a similar current pulse in evacuated capillaries of the same size. Discharges in argon-filled capillaries at currents between 20 and 60 kA produced plasmas with ArX-Ar{sub XIV} line emission, and with spectra that are similar to those of plasmas generated by > I MA current implosions in large pulsed power machines. The characteristic of these plasmas approach those necessary for soft X-ray amplification in low Z elements.

  12. Potential of polyE-323 coated capillaries for capillary electrophoresis of lipids.

    Science.gov (United States)

    Martma, Kert; Lindenburg, Petrus W; Habicht, Kaia-Liisa; Vulla, Kaspar; Resik, Kristiin; Kuut, Gunnar; Shimmo, Ruth

    2013-11-22

    In this note the feasibility of a polyamine-based capillary coating, polyE-323, for capillary electrophoresis (CE) of lipids is explored. PolyE-323 has previously been demonstrated to be suitable to suppress analyte-wall interaction of proteins in CE. However, the full applicability range of polyE-323 has not been exploited yet and it might be useful in the analysis of hydrophobic analytes, such as lipids. In this study, the stability of polyE-323 when using highly organic background electrolytes (BGEs), which are needed to solubilize the lipid analytes, was studied. For this, we used three different lipid samples: sphingomyelin, cardiolipin and a lipid extract from a cell culture. The highly organic BGEs that were used in this study consisted of 94.5% of organic solvents and 5.5% of an aqueous buffer. First, the influence of pure acetonitrile, methanol, propylene carbonate, isopropanol and chloroform on the polyE-323 coating was investigated. Then BGEs were developed and tested, using sphingomyelin and cardiolipin as test analytes in CE-UV experiments. After establishing the best BGEs (in terms of analysis time and repeatability) by CE-UV, sphingomyelin was used as a test analyte to demonstrate that method was also suitable for CE with mass-spectrometry detection (CE-MS). The LOD of sphingomyelin was estimated to be 100 nM and its migration time repeatability was 1.3%. The CE-MS analysis was further applied on a lipid extract obtained from human glioblastoma cells, which resulted in the separation and detection of a multitude of putative lipids. The results of our feasibility study indicate that CE systems based on polyE-323 coated capillaries and highly organic BGEs are promising for fast electromigration-based analysis of lipids.

  13. Principles of Micellar Electrokinetic Capillary Chromatography Applied in Pharmaceutical Analysis

    OpenAIRE

    Árpád Gyéresi; Eleonora Mircia; Brigitta Simon; Aura Rusu; Gabriel Hancu

    2013-01-01

    Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is based on the differences between the own electrophoretic mobilities of the analytes; are hard to achieve...

  14. Micro-magnetic particles frit for capillary electrochromatography.

    Science.gov (United States)

    Oguri, Shigeyuki; Oga, Chiari; Takeda, Haruna

    2007-07-20

    This paper presents a new method for making frit using soft-ferrite-based micro-magnetic particles (MMPs) in a micro-space, such as in a capillary tube. The MMPs-frit was made by injecting an aliquot of 10 microm (outer diameter; o.d.)-MMPs-suspension in methanol (ca. 1mg/ml) into a capillary tube (75 microm inner diameter (i.d.) x 375 microm o.d. x ca. 35 cm length) that was already sandwiched between a pair of cylindrical Neodium (Nd-Fe-B) magnets (1.5 mm o.d. x 1.5 mm height, 280 mT) at a position where the frit was made. The MMPs were trapped in the capillary tube as a frit due to the attraction of the magnets placed at surface on the capillary tube. With regard to durability, the frit was stable for methanol flow with a flow rate of 400 microl/min at room temperature. Using such a frit, a capillary column (20 cm long) was prepared by injecting a 5 microm (o.d.)-ODS-particle suspension in methanol (ca. 0.4 mg/microl) into the capillary tube. The MMPs-frits-ODS-packed column was stable for methanol for a flow pressure less than 20MPa. When comparing the present column with a conventional sintered-frits-ODS-packed column for the purposes of separating five kinds of biogenic amines by means of an on-column derivatization capillary electrochromatography (CEC), the performance of the MMPs-frits capillary column was almost equivalent to that of the sintered-frits-ODS-packed column.

  15. Capillary photoelectrode structures for photoelectrochemical and photocatalytic cells

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xudong; Li, Zhaodong; Cai, Zhiyong; Yao, Chunhua

    2017-05-02

    Photocatalytic structures having a capillary-force based electrolyte delivery system are provided. Also provided are photoelectrochemical and photocatalytic cells incorporating the structures and methods for using the cells to generate hydrogen and/or oxygen from water. The photocatalytic structures use an electrolyte-transporting strip comprising a porous network of cellulose nanofibers to transport electrolyte from a body of the electrolyte to a porous photoelectrode or a porous photocatalytic substrate via capillary force.

  16. Modified monolithic silica capillary for preconcentration of catecholamines

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Preconcentration of catecholamines by the modified monolithic silica in the capillary was investigated in this study. In order to achieve a microchip-based method for determining catecholamines in the saliva,the monolithic silica was fabricated in the capillary and the monolithic silica was chemically modified by on-column reaction with phenylboronate. Different modified methods were compared. The concentration conditions were optimized. This study indicates the applicability of the modified monolithic sili...

  17. Monitoring of enzymatic reactions using capillary electrophoresis with conductivity detection

    OpenAIRE

    2009-01-01

    Capillary electrophoresis combined with contactless conductivity detection allows to separate and detect the ionic species, which are neither UV absorbing nor fluorescent. This thesis focuses on the applications of this method on enzymatic reactions in different analytical tasks. First, the non-ionic species ethanol, glucose, ethyl acetate and ethyl butyrate were made accessible for analysis by capillary electrophoresis via charged products or byproducts obtained in enzymati...

  18. Optimized photonic crystal fibers supporting efficient capillary electrophoresis

    Science.gov (United States)

    Calcerrada, M.; García-Ruiz, C.; Roy, P.; Gonzalez-Herraez, M.

    2013-05-01

    In this paper we present preliminary results on the use of Photonic Crystal Fibers (PCFs) in a conventional capillary electrophoresis system to separate and detect fluorescent species. PCFs show interesting advantages over conventional capillaries for this application, including larger surface-to-volume ratio and potential for higher resolution with comparable sensitivity. Our results illustrate some of these advantages, and we point out the need for stringent tolerances in the fabrication of specific PCFs for this application.

  19. Possibilities of testing capillary absorption on microcores

    Directory of Open Access Journals (Sweden)

    Čeh Arpad

    2016-01-01

    Full Text Available During inspection of reinforced concrete structures from the aspect of durability evaluation of concrete, the present methods generally use the test results obtained by the sophisticated and expensive equipment, which are usually not universal purpose, ie. they can be used only for one segment of durability evaluation of the concrete. This way any additional information about the condition of concrete is valuable, especially if it is not require an additional testing with special equipment. Tests of concrete and reinforced concrete with microcore drilling is considered to be a semi- destructive method, which slightly damages the structure itself, and it is primarily used for testing carbonation, density and absorption of concrete. The paper presents the results of capillary absorption according to SRPS EN 480-5 on standard-size samples and on the microcores extracted from cube form samples with edge length of 20 cm. In the article the testing results of penetration of water under pressure are also presented on the same samples, on which we previously gained microcores. These tests were carried out on with concrete mixtures designed for the most demanding exposure classes according to EN 206-1 and using a variety of additives that are known to affect the structure of pores and consequently also the durability of a hardened concrete.

  20. Capillary electrophoretic behavior of seven sulfonylureas.

    Science.gov (United States)

    Matchett, W H; Winnik, W; Brumley, W C

    1996-01-01

    The electrophoretic behavior of seven sulfonylureas (bensulfuron methyl, sulfometuron methyl, nicosulfuron [accent], chlorimuron ethyl, thifensulfuron methyl [harmony], metsulfuron methyl, and chlorsulfuron) was studied under capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) conditions. Mixtures of these compounds were separated with very high efficiencies (2 x 10(5) theoretical plates) in a running buffer consisting of 3 parts acetate buffer (25 mM, pH 5.0) and 1 part acetonitrile. In this buffer system, acetonitrile was shown to be superior to methanol, acetone, and ethanol as a nonpolar additive, but any of these solvents can be used to reduce electroosmotic flow (EOF) and to obtain adequate separation. On-column detection limits at 214 nM were of the order of 80-100 fM. Micellar agents such as sodium dodecyl sulfate (SDS) and sodium cholate (but not monosialoganglioside-Gm1 or starburst dendrimer, generation 2.5) improved separation in phosphate and borate buffers. Implications of these results for the development of methods to detect these compounds on matrices of environmental origin are discussed. In particular, the instability of these compounds in methanol is noted and degradation products are detected using free zone CE. The methanolysis products of sulfometuron are tentatively identified by tandem MS (negative ion conditions) as 2-amino-4,6-dimethylpyrimidine and 2-carboxymethylbenz(N-carboxymethyl)sulfonamide.

  1. Nitromethane as solvent in capillary electrophoresis.

    Science.gov (United States)

    Subirats, Xavier; Porras, Simo P; Rosés, Martí; Kenndler, Ernst

    2005-06-24

    Nitromethane has several properties that make it an interesting solvent for capillary electrophoresis especially for lipophilic analytes that are not sufficiently soluble in water: freezing and boiling points are suitable for laboratory conditions, low viscosity leads to favourable electrophoretic mobilities, or an intermediate dielectric constant enables dissolution of electrolytes. In the present work we investigate the change of electrophoretically relevant analyte properties - mobilities and pKa values - in nitromethane in dependence on the most important experimental conditions determined by the background electrolyte: the ionic strength, I, and the pH. It was found that the mobility decreases with increasing ionic strength (by, e.g. up to 30% from I = 0 to 50 mmol/L) according to theory. An appropriate pH scale is established by the aid of applying different concentration ratios of a buffer acid with known pKa and its conjugate base. The mobility of the anionic analytes (from weak neutral acids) depends on the pH with the typical sigmoidal curve in accordance with theory. The pKa of neutral acids derived from these curves is shifted by as much as 14 pK units in nitromethane compared to water. Both findings confirm the agreement of the electrophoretic behaviour of the analytes with theories of electrolyte solutions. Separation of several neutral analytes was demonstrated upon formation of charged complexes due to heteroconjugation with chloride as ionic constituent of the background electrolyte.

  2. Fabricating PFPE Membranes for Capillary Electrophoresis

    Science.gov (United States)

    Lee, Michael C.; Willis, Peter A.; Greer, Frank; Rolland, Jason

    2009-01-01

    A process has been developed for fabricating perfluoropolyether (PFPE) membranes that contain microscopic holes of precise sizes at precise locations. The membranes are to be incorporated into laboratory-on-a-chip microfluidic devices to be used in performing capillary electrophoresis. The present process is a modified version of part of the process, described in the immediately preceding article, that includes a step in which a liquid PFPE layer is cured into solid (membrane) form by use of ultraviolet light. In the present process, one exploits the fact that by masking some locations to prevent exposure to ultraviolet light, one can prevent curing of the PFPE in those locations. The uncured PFPE can be washed away from those locations in the subsequent release and cleaning steps. Thus, holes are formed in the membrane in those locations. The most straightforward way to implement the modification is to use, during the ultraviolet-curing step, an ultraviolet photomask similar to the photomasks used in fabricating microelectronic devices. In lieu of such a photomask, one could use a mask made of any patternable ultraviolet-absorbing material (for example, an ink or a photoresist).

  3. Capillary Flow in an Interior Corner

    Science.gov (United States)

    Weislogel, Mark Milton

    1996-01-01

    The design of fluids management processes in the low-gravity environment of space requires an accurate model and description of capillarity-controlled flow in containers of irregular geometry. Here we consider the capillary rise of a fluid along an interior corner of a container following a rapid reduction in gravity. The analytical portion of the work presents an asymptotic formulation in the limit of a slender fluid column, slight surface curvature along the corner, small inertia, and low gravity. New similarity solutions are found and a list of closed form expressions is provided for flow rate and column length. In particular, it is found that the flow is proportional to t(exp 1/2) for a constant height boundary condition, t(exp 2/5) for a spreading drop, and t(exp 3/5) for constant flow. In the experimental portion of the work, measurements from a 2.2s drop tower are reported. An extensive data set, collected over a previously unexplored range of flow parameters, includes estimates of repeatability and accuracy, the role of inertia and column slenderness, and the effects of corner angle, container geometry, and fluid properties. Comprehensive comparisons are made which illustrate the applicability of the analytic results to low-g fluid systems design.

  4. Principles of micellar electrokinetic capillary chromatography applied in pharmaceutical analysis.

    Science.gov (United States)

    Hancu, Gabriel; Simon, Brigitta; Rusu, Aura; Mircia, Eleonora; Gyéresi, Arpád

    2013-01-01

    Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is based on the differences between the own electrophoretic mobilities of the analytes; are hard to achieve. Micellar electrokinetic capillary chromatography, a hybrid method that combines chromatographic and electrophoretic separation principles, extends the applicability of capillary electrophoretic methods to neutral analytes. In micellar electrokinetic capillary chromatography, surfactants are added to the buffer solution in concentration above their critical micellar concentrations, consequently micelles are formed; micelles that undergo electrophoretic migration like any other charged particle. The separation is based on the differential partitioning of an analyte between the two-phase system: the mobile aqueous phase and micellar pseudostationary phase. The present paper aims to summarize the basic aspects regarding separation principles and practical applications of micellar electrokinetic capillary chromatography, with particular attention to those relevant in pharmaceutical analysis.

  5. Principles of Micellar Electrokinetic Capillary Chromatography Applied in Pharmaceutical Analysis

    Directory of Open Access Journals (Sweden)

    Árpád Gyéresi

    2013-02-01

    Full Text Available Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is based on the differences between the own electrophoretic mobilities of the analytes; are hard to achieve. Micellar electrokinetic capillary chromatography, a hybrid method that combines chromatographic and electrophoretic separation principles, extends the applicability of capillary electrophoretic methods to neutral analytes. In micellar electrokinetic capillary chromatography, surfactants are added to the buffer solution in concentration above their critical micellar concentrations, consequently micelles are formed; micelles that undergo electrophoretic migration like any other charged particle. The separation is based on the differential partitioning of an analyte between the two-phase system: the mobile aqueous phase and micellar pseudostationary phase. The present paper aims to summarize the basic aspects regarding separation principles and practical applications of micellar electrokinetic capillary chromatography, with particular attention to those relevant in pharmaceutical analysis.

  6. THE CAPILLARY PATTERN IN HUMAN MASSETER MUSCLE DURING AGEING

    Directory of Open Access Journals (Sweden)

    Erika Cvetko

    2013-10-01

    Full Text Available The effect of ageing on the capillary network in skeletal muscles has produced conflicting results in both, human and animals studies. Some of the inconsistencies are due to non-comparable and biased methods that were applied on thin transversal sections, especially in muscles with complicated morphological structures, such as in human masseter muscle. We present a new immunohistochemical method for staining capillaries and muscle fibres in 100 µm thick sections as well as novel approach to 3D visualization of capillaries and muscle fibres. Applying confocal microscopy and virtual 3D stereological grids, or tracing capillaries in virtual reality, length of capillaries within a muscle volume or length of capillaries adjacent to muscle fibre per fibre length, fibre surface or fibre volume were evaluated in masseter muscle of young and old subjects by an unbiased approach. Our findings show that anatomic capillarity is well maintained in masseter muscle in old subjects; however, vascular remodelling occurs with age, which could be a response to changed muscle function and age-related muscle fibre type transformations.

  7. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography.

    Science.gov (United States)

    Kazarian, Artaches A; Sanz Rodriguez, Estrella; Deverell, Jeremy A; McCord, James; Muddiman, David C; Paull, Brett

    2016-01-28

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L(-1) levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min(-1), and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L(-1) for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%.

  8. Both actin and polyproline interactions of Profilin-1 are required for migration, invasion and capillary morphogenesis of vascular endothelial cells

    Science.gov (United States)

    Ding, Zhijie; Gau, David; Deasy, Bridget; Wells, Alan; Roy, Partha

    2009-01-01

    The objective of the present study was to evaluate how different ligand interactions of profilin-1 (Pfn1), an actin-binding protein that is upregulated during capillary morphogenesis of vascular endothelial cells (VEC), contribute to migration and capillary forming ability of VEC. We adopted a knockdown-knockin experimental system to stably express either fully-functional or mutants of Pfn1 that are impaired in binding to two of its major ligands, actin (H119E mutant) and proteins containing polyproline domains (H133S mutant), in a human dermal microvascular cell line (HmVEC) against near-null endogenous Pfn1 background. We found that silencing endogenous Pfn1 expression in HmVEC leads to slower random migration, reduced velocity of membrane protrusion and a significant impairment in matrigel-induced cord formation. Only re-expression of fully-functional but not any of the two ligand-binding deficient mutants of Pfn1 rescues the above defects. We further show that loss of Pfn1 expression in VEC inhibits three-dimensional capillary morphogenesis, MMP2 secretion and ECM invasion. VEC invasion through ECM is also inhibited when actin and polyproline interactions of Pfn1 are disrupted. Together, these experimental data demonstrate that Pfn1 regulates VEC migration, invasion and capillary morphogenesis through its interaction with both actin and proline-rich ligands. PMID:19607826

  9. Determination of Five Preservatives in Food by Capillary Electrophoresis with Quantum Dot Indirect Laser Induced Fluorescence%毛细管电泳-量子点间接激光诱导荧光检测5种食品防腐剂

    Institute of Scientific and Technical Information of China (English)

    郭东山; 陈冠华; 童明珠; 武传芹; 方柔; 伊聆晓

    2012-01-01

    以碲化镉量子点为荧光背景物质,建立了毛细管电泳-间接激光诱导荧光检测食品中对羟基苯甲酸丙酯、脱氢乙酸钠、山梨酸、苯甲酸和丙酸钠含量的方法,紫外吸收很弱的丙酸钠在本方法中显示为正峰,可被有效检出.研究了碲化镉量子点浓度、背景电解质浓度、pH值、分离电压对分析物峰高和迁移时间的影响.在最佳条件下,对羟基苯甲酸丙酯、脱氢乙酸钠、山梨酸、苯甲酸和丙酸钠在8.5 min内得到分离,检出限分别为0.21,0.32,0.50,0.30和0.36 mg/L,相对标准偏差分别为3.9%,2.1%,2.5%,1.9%和2.3%,平均加标回收率分别为96.8%,93.4%,96.3%,98.1%和99.1%.本方法的检出限及线性范围均优于文献报道结果,对食品中这5种防腐剂检测的结果与高效液相色谱法结果一致.%A new assay has been developed by use of capillary electrophoresis with indirect laser induced fluorescence using cadmium telluride quantum dots as fluorescent background substance to determine propylpareben, sodium dehydroacetate, sorbic acid, benzoic acid and sodium propionate in food, in which the sodium propionate with weak UV absorption can be shown as positive peak and effectively detected. The effect of the parameters such as cadmium telluride quantum dot concentration, background electrolyte concentration, pH and separating voltage on the peak height and migration time of analytes have been studied. Under the optimum conditions, propylpareben, sodium dehydroacetate, sorbic acid, benzoic acid and sodium propionate can be separated within 8.5 min. Their detection limits were 0. 21, 0. 32, 0. 50, 0. 30 and 0. 36 mg/L, relative standard deviations 3. 9% , 2. 1%, 2. 5%, 1.9% and 2. 3%, and average recoveries of spiked samples 96. 8% , 93. 4%, 96. 3%, 98. 1% and 99. 1%, respectively. The detection limits and linear dynamic ranges were better than those reported in the references, and the measurement results for the five

  10. Pancreatic capillary blood flow during caerulein-induced pancreatitis evaluated by a laser-doppler flowmeter in rats Estudo das alterações do fluxo capilar pancreático após infusão de ceruleína avaliado por laser-Doppler em ratos

    Directory of Open Access Journals (Sweden)

    Roberto Ferreira Meirelles Jr.

    2003-01-01

    Full Text Available PURPOSE: The pancreatic capillary blood flow (PCBF was studied to determine its alterations during caerulein-induced pancreatitis in rats. METHODS: Twenty rats were divided in groups: control and caerulein. A laser-Doppler flowmeter to measure PCBF continuously was used. Blood pressure (BP and heart rate (HR were monitored. Serum biochemistry analyses were determined. Histopathological study was performed. RESULTS: The PCBF measured a mean of 109.08 ± 14.54% and 68.24 ± 10.47% in control group and caerulein group, respectively. Caerulein group had a mean decrease of 31.75 ± 16.79%. The serum amylase was 1323.70 ± 239.10U.I-1 and 2184.60 ± 700.46U.I-1 in control and caerulein groups, respectively. There was a significant difference in the PCBF (pOBJETIVO: O fluxo capilar pancreático (FCP foi estudado para determinar suas alterações durante a pancreatite aguda induzida por ceruleína, em ratos. MÉTODOS: Vinte ratos foram divididos em grupo controle e grupo ceruleína. Um laser-Doppler fluxímetro foi empregado para determinar, continuamente, o FCP durante 120 minutos. A pressão arterial média (PAM e a freqüência cardíaca (FC foram determinadas, durante o experimento. Análise bioquímica sérica e estudo histopatológico, por microscopia ótica, do tecido pancreático foram realizados, ao final do experimento. RESULTADOS: O FCP foi em média 109,08 ± 2,17% e 68,24 ± 16,79% nos grupos controle e ceruleína , respectivamente. No grupo ceruleína, houve uma diminuição média de 31,75 ± 16,79%. Os níveis de amilase sérica foram de 1323,70 ± 239,10U.I-1 e 2184,60 ± 700,46U.I-1 nos grupos controle e ceruleína, respectivamente. Houve diferença significante (p<0,05 no FCP e na amilasemia, quando comparado o grupo controle com o grupo ceruleína. Embora micro e macrovacuolização estivessem presentes no grupo ceruleína, não houve diferença histológica entre os grupos. CONCLUSÃO: A diminuição do FCP parece um evento precoce

  11. Inhibitor screening and selectivity assessment against multiple cellular protein kinases by capillary electrophoresis with laser-induced fluorescence detection%毛细管电泳-激光诱导荧光检测用于多个胞内蛋白激酶的抑制剂筛选和选择性评价

    Institute of Scientific and Technical Information of China (English)

    张倩倩; 张雪佩; 张含智; 康经武

    2013-01-01

    A method that can be used for screening protein kinase inhibitors (PKIs) and simultaneously assessing their selectivity is described.The method is based on simultaneously assaying multiple cellular protein kinases by performing capillary electrophoresis (CE) separation and measuring the peak areas of the phosphorylated substrate peptides.The powerful separation capability of CE combined with the highly sensitive and selective laser-induced fluorescence (LIF) detector enables the direct screening of PKIs against cell lysates,which are used as an inexpensive source of enzymes.Four cell lines,three specific substrate peptides labeled with 5-carboxyfluorescein (5-FAM),two relative specific PKIs (TBB and H-89) and one non-specific PKI (staurosporine) were utilized to prove the methodology.With this method,the inhibitory activity of the tested compounds against multiple protein kinases was identified in parallel by comparing the peak areas of the phosphorylated substrates with those obtained in the absence of any inhibitors.The reduced peak area of the phosphorylated substrate definitively represents a positive screening result.Simultaneously,assaying the inhibition of one inhibitor against mutiple cellular protein kinases enables the assessment of its selectivity.Compared to the conventional,single-target screening format,the cell lysate-based multi-target method is more informative,more straightforward and more cost effective.%发展了一种基于毛细管电泳(CE)-激光诱导荧光(LIF)检测的多个细胞内源激酶的抑制剂平行筛选及选择性评价方法.CE高效的分离能力和LIF检测器的高选择性,使得同时测试多个胞内激酶的活性成为可能.共4种细胞系、3种特异性蛋白激酶底物肽、2种选择性蛋白激酶抑制剂和1种非选择性蛋白激酶抑制剂用于方法的建立.特异性底物肽与细胞裂解液混合后孵育,被其相应的激酶选择性地磷酸化,利用CE-LIF分离检测磷酸化产物和底

  12. Determination of Ephedrine and Pseudoephedrine in Ephedra Herb by Capillary Electrophoresis/LED Induced Fluorescence Detector%毛细管电泳/发光二极管诱导荧光法测定麻黄中麻黄碱与伪麻黄碱含量

    Institute of Scientific and Technical Information of China (English)

    徐静; 李军; 胡强; 陈嵘; 李妍; 曹际娟

    2012-01-01

    基于麻黄碱及伪麻黄碱衍生物的光谱及化学性质,设计并构建了毛细管电泳/发光二极管诱导荧光检测系统.对关键光学元件进行组合选择,以蓝光发光二极管为光源,BP 470和BP 530分别为光源滤光片和荧光滤光片,光电倍增管检测信号,并对电泳分离系统的缓冲溶液、分离电压等参数进行优化;以FITC为衍生试剂,10 mmol/L Na2B4O7+ 16 mmol/L SDS为缓冲溶液,12 kV电压下可实现麻黄中麻黄碱和伪麻黄碱的基线分离.在0.25~10 mg/L范围内,麻黄碱和伪麻黄碱标准溶液的质量浓度与荧光响应的峰高之间呈较好的线性关系,相关系数(r)均大于0.99,其检出限分别为0.38 μg/L和0.29 μg/L,峰高的日内重复性(RSD)分别为2.0%和2.2%,日间重复性(RSD)分别为5.4%和5.1%.将该方法用于中药麻黄中麻黄碱和伪麻黄碱的测定,加标回收率分别为94%和107%.%A capillary electrophoresis/light emitting diode ( LED) induced fluorescence detector system was designed and constructed especially for the determination of ephedrine and pseudoephedrine in ephedra herb. According to the spectral and chemical characteristics of ephedrine and pseudoephedrine, the main parts of apparatus were chosen as follows; a blue LED was used as the light source; two band pass filters including BP 470 filter and BP 530 filter were used for the emission light and the fluorescence, respectively, and photomultiplier tube ( PMT) was used as the detection element. The buffer concentration and the separation voltage were optimized. Fluorescein isothiocyanate (FITC) was chosen as the label probe, and 10 mmol/L Na2B4O7(pH 9. 3) +16 mmol/L SDS was used as running buffer. Under the optimal conditions, a baseline separation of two compouds in ephedra herb was achieved under the separation voltage of 12 kV. The method showed good linearity over the concentration range of 0. 25 - 10 mg/L for the two compounds with correlation coefficient more

  13. Analysis of recombinant human growth hormone by capillary electrophoresis with bilayer-coated capillaries using UV and MS detection.

    Science.gov (United States)

    Catai, Jonatan R; Sastre Toraño, Javier; Jongen, Peter M J M; de Jong, Gerhardus J; Somsen, Govert W

    2007-06-01

    The characterization of recombinant human growth hormone (rhGH; somatropin) by capillary electrophoresis (CE) with UV-absorbance and mass spectrometric (MS) detection using capillaries noncovalently coated with polybrene (PB) and poly(vinyl sulfonic acid) (PVS) is demonstrated. Compared with bare fused-silica capillaries, PB-PVS coated capillaries yielded more favorable migration-time reproducibilities and higher separation efficiencies. Optimal separation conditions for the bilayer-coated capillaries comprised a background electrolyte (BGE) of 400 mM Tris phosphate (pH 8.5) yielding migration-time R.S.D.s of less than 1.0% and plate numbers above 300,000 for intact rhGH. The protein was also analyzed using the CE method described in the European Pharmacopoeia (Ph. Eur.) monograph. The pharmacopoeial method gave much longer analysis times (22 min versus 8 min), lower resolution and plate numbers, and consecutive shifts in migration time for rhGH, indicating possible interactions between the protein and the inner capillary wall. Due to stable migration times obtained with the coated capillaries, reliable profiling and quantification of rhGH and its byproducts in time was possible. Analysis of thermally degraded rhGH revealed the formation of two main degradation products. CE-mass spectrometry (MS) of this sample, using a PB-PVS coated capillary and a BGE of 75 mM ammonium formate (pH 8.5), suggests that these products are desamido forms of rhGH. Analyses of expired rhGH preparations with CE-UV and CE-MS indicated the presence of both deamidation and oxidation products.

  14. Very small injected samples to study chloroquine and quinine in human serum using capillary-LC and native fluorescence

    OpenAIRE

    Ibrahim, H.; Bouajila, J.; Siri, N.; Rozing, G.; Nepveu, Françoise; Couderc, F.

    2007-01-01

    A comparison between HPLC with conventional fluorescence detection and capillary-LC (mu HPLC) with native laser-induced fluorescence (LIF) detection was done to determine chloroquine (CQ) and quinine (Q) in human serum. HPLC experiments were run with parameters of the conventional fluorimeter set at the highest level of sensitivity. Results were compared with those obtained on mu HPLC coupled to a ZETALIF (He-Cd 325 nm) detector which provided a 50-fold increase in sensitivity. In mu HPLC-LIF...

  15. Cell biology of mesangial cells: the third cell that maintains the glomerular capillary.

    Science.gov (United States)

    Kurihara, Hidetake; Sakai, Tatsuo

    2017-03-01

    The renal glomerulus consists of glomerular endothelial cells, podocytes, and mesangial cells, which cooperate with each other for glomerular filtration. We have produced monoclonal antibodies against glomerular cells in order to identify different types of glomerular cells. Among these antibodies, the E30 clone specifically recognizes the Thy1.1 molecule expressed on mesangial cells. An injection of this antibody into rats resulted in mesangial cell-specific injury within 15 min, and induced mesangial proliferative glomerulonephritis in a reproducible manner. We examined the role of mesangial cells in glomerular function using several experimental tools, including an E30-induced nephritis model, mesangial cell culture, and the deletion of specific genes. Herein, we describe the characterization of E30-induced nephritis, formation of the glomerular capillary network, mesangial matrix turnover, and intercellular signaling between glomerular cells. New molecules that are involved in a wide variety of mesangial cell functions are also introduced.

  16. Toward high-throughput monitoring of metallodrug-protein interaction using capillary electrophoresis in chemically modified capillaries.

    Science.gov (United States)

    Shmykov, Alexei Y; Filippov, Vladimir N; Foteeva, Lidia S; Keppler, Bernhard K; Timerbaev, Andrei R

    2008-08-15

    The performance of capillary electrophoresis (CE) operating with a sulfonated capillary for the separation of protein adducts of anticancer ruthenium(III)-based drugs was evaluated. The coated capillary was shown to yield improved resolution of albumin- and transferrin-bound species of ruthenium compared with that attained with the bare fused-silica capillary. The coating also showed an increased reproducibility of migration times and peak areas and allowed reasonably high efficiency separation of analytes (up to 1300 theoretical plates per meter), which display high affinity toward a fused-silica surface. In addition, due to rather high electroosmotic flow (EOF, > 45 x 10(-5)cm(2)V(-1)s(-1)) in the coated capillary, it enabled fast counter-EOF monitoring of albumin and transferrin adducts. This benefit, together with requiring only a short flush with the background electrolyte to have migration times reproducible (at capillary holding promise for CE examination of fast reactions such as those accompanying protein-drug interactions and biotransformations associated with drug delivery via protein binding.

  17. Novel covalently coated diazoresin/polyvinyl alcohol capillary column for the analysis of proteins by capillary electrophoresis.

    Science.gov (United States)

    Yu, Bing; Liu, Peng; Cong, Hailin; Tang, Jianguo; Zhang, Lixin

    2012-10-01

    A novel method for the preparation of covalently linked capillary coatings of PVA was demonstrated using photosensitive diazoresin (DR) as coupling agents. Layer-by-layer self-assembly film of DR and PVA based on hydrogen bonding was first fabricated on the inner wall of capillary, then the hydrogen bonding was converted into covalent bonding after treatment with UV light through the unique photochemistry reaction of DR. The covalently bonded coatings suppressed basic protein adsorption on the inner surface of capillary, and thus a baseline separation of lysozyme, cytochrome c and BSA was achieved using CE. Compared with bare capillary or noncovalently bonded DR/PVA coatings, the covalently linked DR/PVA capillary coatings not only improved the CE separation performance for proteins, but also exhibited good stability and repeatability. Due to the replacement of highly toxic and moisture-sensitive silane coupling agent by DR in the covalent coating preparation, this method may provide a green and easy way to make the covalently coated capillaries for CE.

  18. Affinity capillary electrophoresis: the theory of electromigration.

    Science.gov (United States)

    Dubský, Pavel; Dvořák, Martin; Ansorge, Martin

    2016-12-01

    We focus on the state-of-the-art theory of electromigration under single and multiple complexation equilibrium. Only 1:1 complexation stoichiometry is discussed because of its unique status in the field of affinity capillary electrophoresis (ACE). First, we summarize the formulas for the effective mobility in various ACE systems as they appeared since the pioneering days in 1992 up to the most recent theories till 2015. Disturbing phenomena that do not alter the mobility of the analyte directly but cause an unexpected peak broadening have been studied only recently and are also discussed in this paper. Second, we turn our attention to the viscosity effects in ACE. Change in the background electrolyte viscosity is unavoidable in ACE but numerous observations scattered throughout the literature have not been reviewed previously. This leads to an uncritical employment of correction factors that may or may not be appropriate in practice. Finally, we consider the ionic strength effects in ACE, too. Limitations of the current theories are also discussed and the tasks identified where open problems still prevail. Graphical Abstract A weak base (A) undergoes an acidic-basic equilibria (in blue) and migrates with an electrophoretic mobility of [Formula: see text]. Simultaneously, it interacts with a selector (sel) while the analyte-selector complex migrates with an electrophoretic mobility of [Formula: see text]. The strength of the interaction (in orange) is governed by the binding constant, K A , and the concentration of the selector, c sel . This all gives the analyte an effective mobility of [Formula: see text] and moves it out of the zero position (EOF; right top insert). The interaction of the positively charged analyte with the neutral selector slows down the analyte with increasing selector concentration (right bottom insert).

  19. Fluid trapping during capillary displacement in fractures

    Science.gov (United States)

    Yang, Zhibing; Neuweiler, Insa; Méheust, Yves; Fagerlund, Fritjof; Niemi, Auli

    2016-09-01

    The spatial distribution of fluid phases and the geometry of fluid-fluid interfaces resulting from immiscible displacement in fractures cast decisive influence on a range of macroscopic flow parameters. Most importantly, these are the relative permeabilities of the fluids as well as the macroscopic irreducible saturations. They also influence parameters for component (solute) transport, as it usually occurs through one of the fluid phase only. Here, we present a numerical investigation on the critical role of aperture variation and spatial correlation on fluid trapping and the morphology of fluid phase distributions in a geological fracture. We consider drainage in the capillary dominated regime. The correlation scale, that is, the scale over which the two facing fracture walls are matched, varies among the investigated geometries between L/256 and L (self-affine fields), L being the domain/fracture length. The aperture variability is quantified by the coefficient of variation (δ), ranging among the various geometries from 0.05 to 0.25. We use an invasion percolation based model which has been shown to properly reproduce displacement patterns observed in previous experiments. We present a quantitative analysis of the size distribution of trapped fluid clusters. We show that when the in-plane curvature is considered, the amount of trapped fluid mass first increases with increasing correlation scale Lc and then decreases as Lc further increases from some intermediate scale towards the domain length scale L. The in-plane curvature contributes to smoothening the invasion front and to dampening the entrapment of fluid clusters of a certain size range that depends on the combination of random aperture standard deviation and spatial correlation.

  20. Quantification of Carbohydrates in Grape Tissues Using Capillary Zone Electrophoresis.

    Science.gov (United States)

    Zhao, Lu; Chanon, Ann M; Chattopadhyay, Nabanita; Dami, Imed E; Blakeslee, Joshua J

    2016-01-01

    Soluble sugars play an important role in freezing tolerance in both herbaceous and woody plants, functioning in both the reduction of freezing-induced dehydration and the cryoprotection of cellular constituents. The quantification of soluble sugars in plant tissues is, therefore, essential in understanding freezing tolerance. While a number of analytical techniques and methods have been used to quantify sugars, most of these are expensive and time-consuming due to complex sample preparation procedures which require the derivatization of the carbohydrates being analyzed. Analysis of soluble sugars using capillary zone electrophoresis (CZE) under alkaline conditions with direct UV detection has previously been used to quantify simple sugars in fruit juices. However, it was unclear whether CZE-based methods could be successfully used to quantify the broader range of sugars present in complex plant extracts. Here, we present the development of an optimized CZE method capable of separating and quantifying mono-, di-, and tri-saccharides isolated from plant tissues. This optimized CZE method employs a column electrolyte buffer containing 130 mM NaOH, pH 13.0, creating a current of 185 μA when a separation voltage of 10 kV is employed. The optimized CZE method provides limits-of-detection (an average of 1.5 ng/μL) for individual carbohydrates comparable or superior to those obtained using gas chromatography-mass spectrometry, and allows resolution of non-structural sugars and cell wall components (structural sugars). The optimized CZE method was successfully used to quantify sugars from grape leaves and buds, and is a robust tool for the quantification of plant sugars found in vegetative and woody tissues. The increased analytical efficiency of this CZE method makes it ideal for use in high-throughput metabolomics studies designed to quantify plant sugars.

  1. Advances in Capillary Chromatography%毛细管色谱的进展

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The difference of diffusion coefficient in gas and liquid phase is a key role. The study for obtaining a high performance capillary liquid chromatography is discussed. Capillary electrochromatography is recently interesting for its instinct ability to realize a high performance chromatography. Capillary electrochromatography with and without pressurized flow is reviewed briefly. Instrumentation for capillary electrochromatography with pressurized flow is discussed. The port of splitting, and gradient elution of both solution and potential are described. The new findings of both the variation of column resistance and capacity factor according to the value of applied electric voltage are also discussed.

  2. Model and Simulation of a Tunable Birefringent Fiber Using Capillaries Filled with Liquid Ethanol for Magnetic Quasiphase Matching In-Fiber Isolator

    Directory of Open Access Journals (Sweden)

    Clint Zeringue

    2010-01-01

    Full Text Available A technique to tune a magnetic quasi-phase matching in-fiber isolator through the application of stress induced by two mutually orthogonal capillary tubes filled with liquid ethanol is investigated numerically. The results show that it is possible to “tune” the birefringence in these fibers over a limited range depending on the temperature at which the ethanol is loaded into the capillaries. Over this tuning range, the thermal sensitivity of the birefringence is an order-of-magnitude lower than conventional fibers, making this technique well suited for magnetic quasi-phase matching.

  3. Monitoring exocytosis and release from individual mast cells by capillary electrophoresis and UV imaging microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, E.S. [Ames Lab., IA (United States)]|[Iowa State Univ., Ames, IA (United States); Lillard, S.J. [Stanford Univ., CA (United States); McCloskey, M.A. [Iowa State Univ., Ames, IA (United States)

    1997-12-31

    The complex temporal evolution of on-column exocytotic release of serotonin from individual peritoneal mast cells (RPMCs) was monitored by using capillary electrophoresis and UV imaging microscopy. Laser-induced native fluorescence detection with 275-nm excitation was used, and a detection limit of 1.7 amol (S/N = 3; rms) was obtained for serotonin. A physiological running buffer was used to ensure that the cell remained viable throughout. The secretagogue was polymyxin B sulfate (Pmx). Following the injection of a single mast cell into the capillary, electromigration of Pmx toward and past the cell induced degranulation and release of serotonin. The time course of release was registered in the electropherograms with subsecond resolution. Subsequent introduction of SDS caused the cell to lyse completely and allowed the residual serotonin to be quantified. The average amount of serotonin observed per RPMC was 1.6 {+-} 0.6 fmol; the average percentage of serotonin released was 28 {+-} 14%. Events that are consistent with released serontonin from single submicron granules (250 aL each) were evident, each of which contained an average amount of 5.9 {+-} 3 amol. Alternatively, UV movies can be taken of the entire event to provide temporal and spatial information.

  4. On the performance of capillary barriers as landfill cover

    Science.gov (United States)

    Kämpf, M.; Montenegro, H.

    Landfills and waste heaps require an engineered surface cover upon closure. The capping system can vary from a simple soil cover to multiple layers of earth and geosynthetic materials. Conventional design features a compacted soil layer, which suffers from drying out and cracking, as well as root and animal intrusion. Capillary barriers consisting of inclined fine-over-coarse soil layers are investigated as an alternative cover system. Under unsaturated conditions, the textural contrast delays vertical drainage by capillary forces. The moisture that builds up above the contact will flow downdip along the interface of the layers. Theoretical studies of capillary barriers have identified the hydraulic properties of the layers, the inclination angle, the length of the field and the infiltration rate as the fundamental characteristics of the system. However, it is unclear how these findings can lead to design criteria for capillary barriers. To assess the uncertainty involved in such approaches, experiments have been carried out in a 8 m long flume and on large scale test sites (40 m x 15 m). In addition, the ability of a numerical model to represent the relevant flow processes in capillary barriers has been examined.

  5. On the performance of capillary barriers as landfill cover

    Directory of Open Access Journals (Sweden)

    M. Kämpf

    1997-01-01

    Full Text Available Landfills and waste heaps require an engineered surface cover upon closure. The capping system can vary from a simple soil cover to multiple layers of earth and geosynthetic materials. Conventional design features a compacted soil layer, which suffers from drying out and cracking, as well as root and animal intrusion. Capillary barriers consisting of inclined fine-over-coarse soil layers are investigated as an alternative cover system. Under unsaturated conditions, the textural contrast delays vertical drainage by capillary forces. The moisture that builds up above the contact will flow downdip along the interface of the layers. Theoretical studies of capillary barriers have identified the hydraulic properties of the layers, the inclination angle, the length of the field and the infiltration rate as the fundamental characteristics of the system. However, it is unclear how these findings can lead to design criteria for capillary barriers. To assess the uncertainty involved in such approaches, experiments have been carried out in a 8 m long flume and on large scale test sites (40 m x 15 m. In addition, the ability of a numerical model to represent the relevant flow processes in capillary barriers has been examined.

  6. Silver nanoparticle-doped zirconia capillaries for enhanced bacterial filtration.

    Science.gov (United States)

    Wehling, Julia; Köser, Jan; Lindner, Patrick; Lüder, Christian; Beutel, Sascha; Kroll, Stephen; Rezwan, Kurosch

    2015-03-01

    Membrane clogging and biofilm formation are the most serious problems during water filtration. Silver nanoparticle (Agnano) coatings on filtration membranes can prevent bacterial adhesion and the initiation of biofilm formation. In this study, Agnano are immobilized via direct reduction on porous zirconia capillary membranes to generate a nanocomposite material combining the advantages of ceramics being chemically, thermally and mechanically stable with nanosilver, an efficient broadband bactericide for water decontamination. The filtration of bacterial suspensions of the fecal contaminant Escherichia coli reveals highly efficient bacterial retention capacities of the capillaries of 8 log reduction values, fulfilling the requirements on safe drinking water according to the U.S. Environmental Protection Agency. Maximum bacterial loading capacities of the capillary membranes are determined to be 3×10(9)bacterialcells/750mm(2) capillary surface until back flushing is recommendable. The immobilized Agnano remain accessible and exhibit strong bactericidal properties by killing retained bacteria up to maximum bacterial loads of 6×10(8)bacterialcells/750mm(2) capillary surface and the regenerated membranes regain filtration efficiencies of 95-100%. Silver release is moderate as only 0.8% of the initial silver loading is leached during a three-day filtration experiment leading to average silver contaminant levels of 100μg/L.

  7. Hybrid integrated PDMS microfluidics with a silica capillary.

    Science.gov (United States)

    Dimov, Ivan K; Riaz, Asif; Ducrée, Jens; Lee, Luke P

    2010-06-07

    To harness the properties of both PDMS and silica, we have demonstrated hybrid integrated PDMS microfluidic systems with fused silica capillaries. The hybrid integrated PDMS microfluidics and silica capillary (iPSC) modules exhibit a novel architecture and method for leakage free CE sample injection merely requiring a single high voltage source and one pair of electrodes. The use of the iPSC device is based on a modular approach which allows the capillary to be reused extensively whilst replacing the attached fluidic module for different experiments. Integrating fused silica capillaries with PDMS microfluidic modules allows the direct application of a wide variety of well established conventional CE protocols for separations of complex analytes. Furthermore it bears the potential for facile coupling to standard electro-spray ionization mass spectrometry (ESI-MS), letting users focus on the sample analysis rather than the development of new separation protocols. The fabrication of the iPSC module consists of a simple and quick three-step method that submerges a fused silica capillary in PDMS prepolymer. After cross linking the prepolymer and punching the inlets, the iPSC module layer can be mounted onto a microfluidic device for CE separation.

  8. The capillary hysteresis model HYSTR: User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Niemi, A.; Bodvarsson, G.S.

    1991-11-01

    The potential disposal of nuclear waste in the unsaturated zone at Yucca Mountain, Nevada, has generated increased interest in the study of fluid flow through unsaturated media. In the near future, large-scale field tests will be conducted at the Yucca Mountain site, and work is now being done to design and analyze these tests. As part of these efforts a capillary hysteresis model has been developed. A computer program to calculate the hysteretic relationship between capillary pressure {phi} and liquid saturation (S{sub 1}) has been written that is designed to be easily incorporated into any numerical unsaturated flow simulator that computes capillary pressure as a function of liquid saturation. This report gives a detailed description of the model along with information on how it can be interfaced with a transport code. Although the model was developed specifically for calculations related to nuclear waste disposal, it should be applicable to any capillary hysteresis problem for which the secondary and higher order scanning curves can be approximated from the first order scanning curves. HYSTR is a set of subroutines to calculate capillary pressure for a given liquid saturation under hysteretic conditions.

  9. Viscoelastic capillary flow: the case of whole blood

    Directory of Open Access Journals (Sweden)

    David Rabaud

    2016-07-01

    Full Text Available The dynamics of spontaneous capillary flow of Newtonian fluids is well-known and can be predicted by the Lucas-Washburn-Rideal (LWR law. However a wide variety of viscoelastic fluids such as alginate, xanthan and blood, does not exhibit the same Newtonian behavior.In this work we consider the Herschel-Bulkley (HB rheological model and Navier-Stokes equation to derive a generic expression that predicts the capillary flow of non-Newtonian fluids. The Herschel-Bulkley rheological model encompasses a wide variety of fluids, including the Power-law fluids (also called Ostwald fluids, the Bingham fluids and the Newtonian fluids. It will be shown that the proposed equation reduces to the Lucas-Washburn-Rideal law for Newtonian fluids and to the Weissenberg-Rabinowitsch-Mooney (WRM law for power-law fluids. Although HB model cannot reduce to Casson’s law, which is often used to model whole blood rheology, HB model can fit the whole blood rheology with the same accuracy.Our generalized expression for the capillary flow of non-Newtonian fluid was used to accurately fit capillary flow of whole blood. The capillary filling of a cylindrical microchannel by whole blood was monitored. The blood first exhibited a Newtonian behavior, then after 7 cm low shear stress and rouleaux formation made LWR fails to fit the data: the blood could not be considered as Newtonian anymore. This non-Newtonian behavior was successfully fit by the proposed equation.

  10. Manufacturing of flat porous structures for capillary pump applications

    Energy Technology Data Exchange (ETDEWEB)

    Reimbrecht, E.G.; Wendhausen, P.A.P.; Fredel, M.C.; Bazzo, E. [Dept. of Mechanical Engineering, Univ. Federal de Santa Catarina-UFSC, Florianopolis (Brazil)

    2001-07-01

    A flat porous structure is proposed to be used as wick in capillary pumps to move the working fluid in two-phase heat transfer loops. Capillary pumps have been studied to become a reliable alternative for isothermalization and thermal control of satellites and space stations. Sintered nickel powder is an alternative to produce capillary structures, once it presents appropriate sinterability and it is compatible with current working fluids (e.g. ammonia). The desirable parameters for the capillary structure are a porosity level of about 60% and a mean pore size smaller than 10 {mu}m. The flat porous elements was produced by a loose powder sintering and powder injection molding. Powder size and shape, sintering process, sintering time and sintering temperature, were investigated in order to achieve the desired porosity and mechanical resistance. Analyses were accomplished to characterize the capillary structure, and to determine the appropriate manufacturing route. The porosity was determined by using the method of Arquimedes and the porous structures analyzed by scanning electron microscopy. (orig.)

  11. Dynamics of VUV spectra in fast capillary discharge

    Science.gov (United States)

    Antsiferov, P. S.; Dorokhin, L. A.; Koshelev, K. N.

    2011-09-01

    The temporal behavior of VUV spectra of capillary discharge with a rate of a current rise on the order of 1012 A/s is studied. The current is generated using an inductive storage unit with a plasma-erosion opening switch. This discharge is accompanied by the generation of a shock wave on an inner wall of a capillary and by its subsequent cumulation on the discharge axis. The capillary is prefilled with argon at a pressure of 80 Pa. Radiation spectra are obtained using an off-Rowland spectrograph based on a concave grating with optimal focusing in the wavelength range of 20 nm. The radiation is recorded with a detector based on a microchannel plate with a time resolution of 20 ns, which makes it possible to separate the spectra of two phases of the discharge, i.e., the cumulation phase of the shock wave in argon that fills the capillary ( T e ˜ 20-30 eV) and the phase of subsequent discharge in a substance desorbed from the capillary wall T e ˜ 50 eV).

  12. Retinal Capillary Rarefaction in Patients with Type 2 Diabetes Mellitus

    Science.gov (United States)

    Jumar, Agnes; Harazny, Joanna M.; Ott, Christian; Friedrich, Stefanie; Kistner, Iris; Striepe, Kristina

    2016-01-01

    Purpose In diabetes mellitus type 2, capillary rarefaction plays a pivotal role in the pathogenesis of end-organ damage. We investigated retinal capillary density in patients with early disease. Methods This cross-sectional study compares retinal capillary rarefaction determined by intercapillary distance (ICD) and capillary area (CapA), measured non-invasively and in vivo by scanning laser Doppler flowmetry, in 73 patients with type 2 diabetes, 55 healthy controls and 134 individuals with hypertension stage 1 or 2. Results In diabetic patients, ICD was greater (23.2±5.5 vs 20.2±4.2, p = 0.013) and CapA smaller (1592±595 vs 1821±652, p = 0.019) than in healthy controls after adjustment for differences in cardiovascular risk factors between the groups. Compared to hypertensive patients, diabetic individuals showed no difference in ICD (23.1±5.8, p = 0.781) and CapA (1556±649, p = 0.768). Conclusion In the early stage of diabetes type 2, patients showed capillary rarefaction compared to healthy individuals. PMID:27935938

  13. A capillary valve for microfluidic systems.

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, Eric B.; Kanouff, Michael P.; Rush, Brian M.

    2004-10-01

    Microfluidic systems are becoming increasingly complicated as the number of applications grows. The use of microfluidic systems for chemical and biological agent detection, for example, requires that a given sample be subjected to many process steps, which requires microvalves to control the position and transport of the sample. Each microfluidic application has its own specific valve requirements and this has precipitated the wide variety of valve designs reported in the literature. Each of these valve designs has its strengths and weaknesses. The strength of the valve design proposed here is its simplicity, which makes it easy to fabricate, easy to actuate, and easy to integrate with a microfluidic system. It can be applied to either gas phase or liquid phase systems. This novel design uses a secondary fluid to stop the flow of the primary fluid in the system. The secondary fluid must be chosen based on the type of flow that it must stop. A dielectric fluid must be used for a liquid phase flow driven by electroosmosis, and a liquid with a large surface tension should be used to stop a gas phase flow driven by a weak pressure differential. Experiments were carried out investigating certain critical functions of the design. These experiments verified that the secondary fluid can be reversibly moved between its 'valve opened' and 'valve closed' positions, where the secondary fluid remained as one contiguous piece during this transport process. The experiments also verified that when Fluorinert is used as the secondary fluid, the valve can break an electric circuit. It was found necessary to apply a hydrophobic coating to the microchannels to stop the primary fluid, an aqueous electrolyte, from wicking past the Fluorinert and short-circuiting the valve. A simple model was used to develop valve designs that could be closed using an electrokinetic pump, and re-opened by simply turning the pump off and allowing capillary forces to push the secondary

  14. Nonaqueous capillary electrophoresis of dextromethorphan and its metabolites.

    Science.gov (United States)

    Pelcová, Marta; Langmajerová, Monika; Cvingráfová, Eliška; Juřica, Jan; Glatz, Zdeněk

    2014-10-01

    This study deals with the nonaqueous capillary electrophoretic separation of dextromethorphan and its metabolites using a methanolic background electrolyte. The optimization of separation conditions was performed in terms of the resolution of dextromethorphan and dextrorphan and the effect of separation temperature, voltage, and the characteristics of the background electrolyte were studied. Complete separation of all analytes was achieved in 40 mM ammonium acetate dissolved in methanol. Hydrodynamic injection was performed at 3 kPa for 4 s. The separation voltage was 20 kV accompanied by a low electric current. The ultraviolet detection was performed at 214 nm, the temperature of the capillary was 25°C. These conditions enabled the separation of four analytes plus the internal standard within 9 min. Further, the developed method was validated in terms of linearity, sensitivity, and repeatability. Rat liver perfusate samples were subjected to the nonaqueous capillary electrophoretic method to illustrate its applicability.

  15. Analysis of White Blood Cell Dynamics in Nailfold Capillaries

    Science.gov (United States)

    Bourquard, Aurélien; Butterworth, Ian; Sánchez-Ferro, Alvaro; Giancardo, Luca; Soenksen, Luis; Cerrato, Carolina; Flores, Rafael; Castro-González, Carlos

    2016-01-01

    Based on video data acquired with low-cost, portable microscopy equipment, we introduce a semi-automatic method to count visual gaps in the blood flow as a proxy for white blood cells (WBC) passing through nailfold capillaries. Following minimal user interaction and a pre-processing stage, our method consists in the spatio-temporal segmentation and analysis of capillary profiles. Besides the mere count information, it also estimates the speed associated with every WBC event. The accuracy of our algorithm is validated through the analysis of two capillaries acquired from one healthy subject. Results are compared with manual counts from four human raters and confronted with related physiological data reported in literature. PMID:26738019

  16. Capillary-inertial colloidal catapults upon drop coalescence

    Science.gov (United States)

    Chavez, Roger L.; Liu, Fangjie; Feng, James J.; Chen, Chuan-Hua

    2016-07-01

    Surface energy released upon drop coalescence is known to power the self-propelled jumping of liquid droplets on superhydrophobic solid surfaces, and the jumping droplets can additionally carry colloidal payloads toward self-cleaning. Here, we show that drop coalescence on a spherical particle leads to self-propelled launching of the particle from virtually any solid surface. The main prerequisite is an intermediate wettability of the particle, such that the momentum from the capillary-inertial drop coalescence process can be transferred to the particle. By momentum conservation, the launching velocity of the particle-drop complex is proportional to the capillary-inertial velocity based on the drop radius and to the fraction of the liquid mass in the total mass. The capillary-inertial catapult is not only an alternative mechanism for removing colloidal contaminants, but also a useful model system for studying ballistospore launching.

  17. Influence of roughness on capillary forces between hydrophilic surfaces

    Science.gov (United States)

    van Zwol, P. J.; Palasantzas, G.; de Hosson, J. Th. M.

    2008-09-01

    Capillary forces have been measured by atomic force microscopy in the plate-sphere setup between gold, borosilicate glass, GeSbTe, titanium, and UV-irradiated amorphous titanium-dioxide surfaces. The force measurements were performed as a function contact time and surface roughness in the range 0.2-15nm rms and relative humidity ranging between 2% and 40%. It is found that even for the lowest attainable relative humidity (˜2%±1%) very large capillary forces are still present. The latter suggests the persistence of a nanometers-thick adsorbed water layer that acts as a capillary bridge between contacting surfaces. Moreover, we found a significantly different scaling behavior of the force with rms roughness for materials with different hydrophilicity as compared to gold-gold surfaces.

  18. Capillary-mediated interface perturbations: Deterministic pattern formation

    Science.gov (United States)

    Glicksman, Martin E.

    2016-09-01

    Leibniz-Reynolds analysis identifies a 4th-order capillary-mediated energy field that is responsible for shape changes observed during melting, and for interface speed perturbations during crystal growth. Field-theoretic principles also show that capillary-mediated energy distributions cancel over large length scales, but modulate the interface shape on smaller mesoscopic scales. Speed perturbations reverse direction at specific locations where they initiate inflection and branching on unstable interfaces, thereby enhancing pattern complexity. Simulations of pattern formation by several independent groups of investigators using a variety of numerical techniques confirm that shape changes during both melting and growth initiate at locations predicted from interface field theory. Finally, limit cycles occur as an interface and its capillary energy field co-evolve, leading to synchronized branching. Synchronous perturbations produce classical dendritic structures, whereas asynchronous perturbations observed in isotropic and weakly anisotropic systems lead to chaotic-looking patterns that remain nevertheless deterministic.

  19. Formation and rupture of capillary bridges in atomic scale friction

    Science.gov (United States)

    Barel, Itay; Filippov, Aleksander E.; Urbakh, M.

    2012-10-01

    While formation of capillary bridges significantly contributes to the adhesion and friction at micro- and nanoscales, many key aspects of dynamics of capillary condensation and its effect on friction forces are still not well understood. Here, by analytical model and numerical simulations, we address the origin of reduction of friction force with velocity and increase of friction with temperature, which have been experimentally observed under humid ambient conditions. These observations differ significantly from the results of friction experiments carried out under ultrahigh vacuum, and disagree with predictions of thermal Prandtl-Tomlinson model of friction. Our calculations demonstrate what information on the kinetics of capillary condensation can be extracted from measurements of friction forces and suggest optimal conditions for obtaining this information.

  20. Enantiomeric resolution of multiple chiral centres racemates by capillary electrophoresis.

    Science.gov (United States)

    Ali, Imran; Suhail, Mohd; Al-Othman, Zeid A; Alwarthan, Abdulrahman; Aboul-Enein, Hassan Y

    2016-05-01

    Enantiomeric resolution of multichiral centre racemates is an important area as some multichiral centre racemates are of great medicinal importance. However, enantioseparation of such types of racemates is a challenging task. Amongst many analytical techniques, capillary electrophoresis is a powerful technique and may be used to resolve such racemates. Only few papers are available describing enantiomeric resolution of such racemates. Therefore, efforts have been made to describe the enantiomeric resolution of multichiral centre racemates by capillary electrophoresis. This article discusses the importance of multichiral racemates, the need for capillary electrophoresis in enantiomeric resolution and chiral resolution of multichiral centre racemates using various chiral selectors. Further, attempts have been made to discuss the future challenges and prospects of enantiomeric resolution of multichiral racemates. The various chiral selectors used for the purpose are chiral crown ether, cyclodextrins, polysaccharides, macrocyclic glycopeptide antibiotics and ligand exchange.

  1. Differential Capillary Effect Model of Fabric and Its Application

    Institute of Scientific and Technical Information of China (English)

    王其; 冯勋伟

    2003-01-01

    The concept of the differential capillary effect was presented by foreign scholars several years ago, and the principle was used to design sportswear fabrics with good wet permeability and good drying functions for famous sports teams. Because the differential capillary effect model was not established in theory,it was impossible to fulfill the best functions. In this paper, by setting up the differential capillary effect of fabric, the factors to influence wet permeability and drying functions of the model is discussed in theory, and the means to optimize the design of the fabric is presented and proven practically by the experiment. The optimum fabric with good permeability and good drying functions can be designed using the model at last.

  2. Numerical simulation of the resonantly excited capillary-gravity waves

    Science.gov (United States)

    Hanazaki, Hideshi; Hirata, Motonori; Okino, Shinya

    2015-11-01

    Capillary gravity waves excited by an obstacle are investigated by a direct numerical simulation. In the flow without capillary effects, it is well known that large-amplitude upstream advancing solitary waves are generated periodically under the resonant condition, i.e., when the phase velocity of the long surface waves and the mean flow velocity agrees. With capillary effects, solutions of the Euler equations show the generation of very short waves further upstream of the solitary waves and also in the depression region downstream of the obstacle. The overall characteristics of these waves agree with the solutions of the forced fifth-order KdV equation, while the weakly nonlinear theory generally overestimates the wavelength of the short waves.

  3. Three-Dimensional Reconstruction of Erythrocyte in the Capillary

    CERN Document Server

    Fan, Yifang; Li, Zhiyu; Lin, Wentao; Wei, Yuan; Zhong, Xing; Newman, Tony; Lv, Changsheng; Fan, Yuzhou

    2013-01-01

    The dynamic analysis of erythrocyte deformability is used as an important means for early diagnosis of blood diseases and blood rheology. Yet no effective method is available in terms of three-dimensional reconstruction of erythrocytes in a capillary. In this study, ultrathin serial sections of skeletal muscle tissue are obtained from the ultramicrotome, the tomographic images of an erythrocyte in a capillary are captured by the transmission electron microscope, and then a method to position and restore is devised to demonstrate the physiological relationship between two adjacent tomographic images of an erythrocyte. Both the modeling and the physical verification reveal that this method is effective, which means that it can be used to make three-dimensional reconstruction of an erythrocyte in a capillary. An example of reconstructed deformation of erythrocyte based on the serial ultrathin sections is shown at the end of this paper.

  4. Crystal growth from the melt by capillary shaping techniques

    Science.gov (United States)

    Ossipyan, Y. A.; Tatarchenko, V. A.

    A method based on the Lyapunov stability theory has been developed for studying the stability of crystallization by capillary shaping techniques (including Czochralski, Stepanov, EFG, Verneuil and floating zone methods). The preliminary results of the analysis of stability shows that the crystallization by capillary shaping technique under microgravitation conditions is more stable in some cases than under the action of gravitation. To get deeper into details of the capillary shaping technique under microgravitation conditions, we have carried out model experiments using two immiscible liquids of equal density and crystallization of sapphire in terrestrial conditions with small Bond number. The experiments on the copper crystallization were realized in the high-altitude rockets. Our experiments on indium crystallization carried out in the orbital space probe “Salyut” yielded cylindrical specimens.

  5. In-capillary approach to eliminate SDS interferences in antibody analysis by capillary electrophoresis coupled to mass spectrometry.

    Science.gov (United States)

    Sánchez-Hernández, Laura; Montealegre, Cristina; Kiessig, Steffen; Moritz, Bernd; Neusüß, Christian

    2016-12-23

    Capillary electrophoresis is an important technique for the characterization of monoclonal antibodies (mAbs), especially in the pharmaceutical context. However, identification is difficult as upscaling and hyphenation of used methods directly to mass spectrometry is often not possible due to separation medium components that are incompatible with MS detection. Here a CE-MS method for the analysis of mAbs is presented analyzing SDS-complexed samples. To obtain narrow and intensive peaks of SDS-treated antibodies, an in-capillary strategy was developed based on the co-injection of positively charged surfactants and methanol as organic solvent. For samples containing 0.2% (v/v) of SDS, recovered MS peak intensities up to 97 and 95% were achieved using cetyltrimethylammonium bromide or benzalkonium chloride, respectively. Successful removal of SDS was shown in neutral coated capillaries but also in a capillary with a positively charged coating applying reversed polarity. The usefulness of this in-capillary strategy was demonstrated also for other proteins and for antibodies dissolved in up to 10% v/v SDS solution, and in other SDS-containing matrices, including the sieving matrix used in a standard CE-SDS method and gel-buffers applied in SDS-PAGE methods. The developed CE-MS approaches enable fast and reproducible characterization of SDS-complexed antibodies.

  6. Development of a capillary electrophoresis-mass spectrometry method using polymer capillaries for metabolomic analysis of yeast.

    Science.gov (United States)

    Tanaka, Yoshihide; Higashi, Tetsuji; Rakwal, Randeep; Wakida, Shin-ichi; Iwahashi, Hitoshi

    2008-05-01

    Metabolomics is an emerging field in analytical biochemistry, and the development of such a method for comprehensive and quantitative analysis of organic acids, carbohydrates, and nucleotides is a necessity in the era of functional genomics. When a concentrated yeast extract was analyzed by CE-MS using a successive multiple ionic-polymer layer (SMIL)-coated capillary, the adsorption of the contaminants on the capillary wall caused severe problems such as no elution, band-broadening, and asymmetric peaks. Therefore, an analytical method for the analysis of anionic metabolites in yeast was developed by pressure-assisted CE using an inert polymer capillary made from poly(ether etherketone) (PEEK) and PTFE. We preferred to use the PEEK over the PTFE capillary in CE-MS due to the easy-to-use PEEK capillary and its high durability. The separation of anionic metabolites was successfully achieved with ammonium hydrogencarbonate/formate buffer (pH 6.0) as the electrolyte solution. The use of 2-propanol washing after every electrophoresis run not only eliminated wall-adsorption phenomena, but allowed for good repeatability to be obtained for migration times in the metabolomic analysis.

  7. Capillary electrophoresis with noncovalently bilayer-coated capillaries for stability study of allergenic proteins in simulated gastrointestinal fluids.

    Science.gov (United States)

    Zheng, Chang; Liu, Youping; Zhou, Qiuhong; Di, Xin

    2010-10-15

    A novel noncovalently bilayer-coated capillary using cationic polymer polybrene (PB) and anionic polymer (sodium 4-styrenesulfonate) (PSS) as coatings was prepared. This PB-PSS coating showed good migration-time reproducibility for proteins and high stability in the range of pH 2-10 and in the presence of 1M NaOH, acetonitrile and methanol. Capillary electrophoresis with PB-PSS coated capillaries was successfully applied to quantitatively investigate the stability of bovine serum albumin, ovomucoid, β-lactoglobulin and lysozyme in simulated gastrointestinal fluids. β-lactoglobulin A and β-lactoglobulin B were both stable in simulated gastric fluid with degradation percentages of 34.3% and 17.2% after 60min of incubation, respectively. Bovine serum albumin, ovomucoid and lysozyme were stable in simulated intestinal fluid with degradation percentages of 17.7%, 23.4% and 22.8% after 60min of incubation, respectively. The superiority of the proposed method over sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and capillary electrophoresis with untreated fused silica capillaries was demonstrated and emphasized.

  8. Electrical Stimulation of Denervated Rat Skeletal Muscle Retards Capillary and Muscle Loss in Early Stages of Disuse Atrophy

    Directory of Open Access Journals (Sweden)

    Kouki Nakagawa

    2017-01-01

    Full Text Available The purpose of the present study is to investigate the effects of low-frequency electrical muscle stimulation (ES on the decrease in muscle mass, fiber size, capillary supply, and matrix metalloproteinase (MMP immunoreactivity in the early stages of denervation-induced limb disuse. Direct ES was performed on the tibialis anterior muscle following denervation in seven-week-old male rats. The rats were divided into the following groups: control (CON, denervation (DN, and denervation with direct ES (DN + ES. Direct ES was performed at an intensity of 16 mA and a frequency of 10 Hz for 30 min per day, six days a week, for one week. We performed immunohistochemical staining to determine the expression of dystrophin, CD34, and MMP-2 in transverse sections of TA muscles. The weight, myofiber cross-sectional area (FCSA, and capillary-to-fiber (C/F ratio of the tibialis anterior (TA muscle were significantly reduced in the DN group compared to the control and DN + ES groups. The MMP-2 positive area was significantly greater in DN and DN + ES groups compared to the control group. These findings suggest beneficial effects of direct ES in reducing muscle atrophy and capillary regression without increasing MMP-2 immunoreactivity in the early stages of DN-induced muscle disuse in rat hind limbs.

  9. Intense intermittent exercise provides weak stimulus for vascular endothelial growth factor secretion and capillary growth in skeletal muscle

    DEFF Research Database (Denmark)

    Høier, Birgitte; Passos, Madla; Bangsbo, Jens

    2013-01-01

    The effect of acute intense intermittent exercise compared to moderate intensity exercise, on angiogenic factors and the effect of four weeks of intense intermittent training on capillary growth were examined in nine young healthy males, pre-conditioned by moderate intensity endurance training. T...... for VEGF secretion and endothelial cell proliferation and that intense intermittent training does not induce a sufficient angiogenic stimulus to induce capillary growth in muscle previously conditioned by moderate intensity exercise.......The effect of acute intense intermittent exercise compared to moderate intensity exercise, on angiogenic factors and the effect of four weeks of intense intermittent training on capillary growth were examined in nine young healthy males, pre-conditioned by moderate intensity endurance training....... The intense training consisted of 24 one-min cycling bouts at an initial work rate of 316 ± 19W (~117% of pre VO2 max), performed 3 times/week. Skeletal muscle biopsies and muscle microdialysates were otained from m.v. lateralis before, during, and after acute exercise performed at either moderate or high...

  10. Investigation into the suitability of capillary tubes for microcrystalline testing.

    Science.gov (United States)

    Elie, Leonie E; Baron, Mark G; Croxton, Ruth S; Elie, Mathieu P

    2013-07-01

    A comparison between microcrystalline tests performed on microscope slides and flat capillary tubes with inner diameters ranging from 0.1 to 0.7 mm was carried out to explore the appropriateness of tubes for rapid testing of suspected drugs of abuse in the laboratory as well as in the field. Tests for mephedrone, cocaine, and phencyclidine were chosen as examples to investigate the handling of the capillary tubes, the influence on crystal habit, size, and the effects on the limit of detection. Image stacking software was used to increase the depth of field of micrographs taken from developed microcrystals greatly enhancing the interpretability even months after carrying out the microcrystalline test. Additionally, the potential of seeding capillary tubes with a reagent was studied. Pre-treatment of tubes would allow microcrystalline tests to be carried out quicker and anywhere without the necessity of taking along expensive and hazardous reagents. The sealing of capillary tubes containing developed microcrystalline tests in order to preserve results for a long period of time was successfully done by applying paraffin wax to the open ends. Finally, it was concluded that capillary tubes are suitable vessels for performing microcrystalline tests. The increased portability of the improved set-up allows tests to be safely executed outside laboratories without impairing the quality of the result. Findings were applied to six legal high samples purchased online between May and August 2011. The active ingredients like MDAI as well as cutting agents like caffeine were successfully identified using the microcrystalline test technique in capillary tubes.

  11. Molecular transport through capillaries made with atomic-scale precision

    Science.gov (United States)

    Radha, B.; Esfandiar, A.; Wang, F. C.; Rooney, A. P.; Gopinadhan, K.; Keerthi, A.; Mishchenko, A.; Janardanan, A.; Blake, P.; Fumagalli, L.; Lozada-Hidalgo, M.; Garaj, S.; Haigh, S. J.; Grigorieva, I. V.; Wu, H. A.; Geim, A. K.

    2016-10-01

    Nanometre-scale pores and capillaries have long been studied because of their importance in many natural phenomena and their use in numerous applications. A more recent development is the ability to fabricate artificial capillaries with nanometre dimensions, which has enabled new research on molecular transport and led to the emergence of nanofluidics. But surface roughness in particular makes it challenging to produce capillaries with precisely controlled dimensions at this spatial scale. Here we report the fabrication of narrow and smooth capillaries through van der Waals assembly, with atomically flat sheets at the top and bottom separated by spacers made of two-dimensional crystals with a precisely controlled number of layers. We use graphene and its multilayers as archetypal two-dimensional materials to demonstrate this technology, which produces structures that can be viewed as if individual atomic planes had been removed from a bulk crystal to leave behind flat voids of a height chosen with atomic-scale precision. Water transport through the channels, ranging in height from one to several dozen atomic planes, is characterized by unexpectedly fast flow (up to 1 metre per second) that we attribute to high capillary pressures (about 1,000 bar) and large slip lengths. For channels that accommodate only a few layers of water, the flow exhibits a marked enhancement that we associate with an increased structural order in nanoconfined water. Our work opens up an avenue to making capillaries and cavities with sizes tunable to ångström precision, and with permeation properties further controlled through a wide choice of atomically flat materials available for channel walls.

  12. Microscale capillary wave turbulence excited by high frequency vibration.

    Science.gov (United States)

    Blamey, Jeremy; Yeo, Leslie Y; Friend, James R

    2013-03-19

    Low frequency (O(10 Hz-10 kHz)) vibration excitation of capillary waves has been extensively studied for nearly two centuries. Such waves appear at the excitation frequency or at rational multiples of the excitation frequency through nonlinear coupling as a result of the finite displacement of the wave, most often at one-half the excitation frequency in so-called Faraday waves and twice this frequency in superharmonic waves. Less understood, however, are the dynamics of capillary waves driven by high-frequency vibration (>O(100 kHz)) and small interface length scales, an arrangement ideal for a broad variety of applications, from nebulizers for pulmonary drug delivery to complex nanoparticle synthesis. In the few studies conducted to date, a marked departure from the predictions of classical Faraday wave theory has been shown, with the appearance of broadband capillary wave generation from 100 Hz to the excitation frequency and beyond, without a clear explanation. We show that weak wave turbulence is the dominant mechanism in the behavior of the system, as evident from wave height frequency spectra that closely follow the Rayleigh-Jeans spectral response η ≈ ω(-17/12) as a consequence of a period-halving, weakly turbulent cascade that appears within a 1 mm water drop whether driven by thickness-mode or surface acoustic Rayleigh wave excitation. However, such a cascade is one-way, from low to high frequencies. The mechanism of exciting the cascade with high-frequency acoustic waves is an acoustic streaming-driven turbulent jet in the fluid bulk, driving the fundamental capillary wave resonance through the well-known coupling between bulk flow and surface waves. Unlike capillary waves, turbulent acoustic streaming can exhibit subharmonic cascades from high to low frequencies; here it appears from the excitation frequency all the way to the fundamental modes of the capillary wave at some four orders of magnitude in frequency less than the excitation frequency

  13. Laser-driven plasma waves in capillary tubes.

    Science.gov (United States)

    Wojda, F; Cassou, K; Genoud, G; Burza, M; Glinec, Y; Lundh, O; Persson, A; Vieux, G; Brunetti, E; Shanks, R P; Jaroszynski, D; Andreev, N E; Wahlström, C-G; Cros, B

    2009-12-01

    The excitation of plasma waves over a length of up to 8 cm is demonstrated using laser guiding of intense laser pulses through hydrogen-filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift-measured as a function of filling pressure, capillary tube length, and incident laser energy-is in excellent agreement with simulation results. The longitudinal accelerating field inferred from the simulations is in the range of 1-10 GV/m.

  14. Simple model of capillary condensation in cylindrical pores

    Science.gov (United States)

    Szybisz, Leszek; Urrutia, Ignacio

    2002-11-01

    A simple model based on an approximation of the dropletlike model is formulated for studying adsorption of fluids into cylindrical pores. This model yields a nearly universal description of capillary condensation transitions for noble gases confined by alkali metals. The system's thermodynamical behavior is predicted from the values of two dimensionless parameters: D* (the reduced asymptotic strength of the fluid-adsorber interaction, a function of temperature) and R* (the reduced radius of the pore). The phenomenon of hysteresis inherently related to capillary condensation is discussed. The connection to a previously proposed universality for cylindrical pores is also established.

  15. Intralesional bleomycin for the treatment of periocular capillary hemangiomas

    Directory of Open Access Journals (Sweden)

    Derrick P Smit

    2012-01-01

    Full Text Available Periocular infantile capillary hemangiomas do not always respond well to conventional treatment modalities such as systemic or intralesional corticosteroids, radiotherapy or debulking surgery. The authors describe the use of intralesional bleomycin injections (IBIs to treat potentially amblyogenic lesions in two cases where other modalities have failed. In both cases monthly IBIs successfully cleared the visual axis of the affected eye before the age of 1 year thus preventing permanent sensory deprivation amblyopia. A total of five and nine injections, respectively, were used and no significant side effects were noted. IBI appears to be a useful alternative in the treatment of periocular capillary hemangiomas refractory to more conventional modalities.

  16. Bubble deformations in corrugated microchannels at large capillary numbers

    Science.gov (United States)

    Cubaud, Thomas; Sauzade, Martin

    2016-11-01

    Multiphase flows in confined microgeometries display a variety of intriguing dynamics. Here, we experimentally examine trains of monodisperse gas bubbles of different sizes and concentrations passing through a series of extensions and constrictions from low to large capillary numbers. Using highly viscous carrier fluids, we show in particular that bubbles strongly deform in velocity fields set with the channel geometry. We measure the instantaneous front and rear velocities of periodically distorted capillary surfaces and develop functional relationships for predicting the morphology of multiphase flow patterns at the pore scale. This work is supported by NSF (CBET-1150389).

  17. [De novo growth of a capillary hemangioma of the conjunctiva].

    Science.gov (United States)

    Fernández-Vega Cueto, L; Tresserra, F; de la Paz, M F

    2014-03-01

    A 22-year-old woman patient, diagnosed with an inclusion cyst of the conjunctiva in the nasal sector of the left eye, who after 2 shot/needle injections in the lesion came to our clinic with a dense subconjunctival hemorrhage in four quadrants and with severe pain. After excision biopsy, a capillary hemangioma of the conjunctiva was diagnosed. Conjunctival capillary hemangioma is mainly a benign lesion, asymptomatic and mostly congenital in origin, its progression or de novo growth is rare in adulthood. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  18. Analysis of phenolic type antioxidants; Capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, S.K. (Indian Inst. of Petroleum, Dehradun (India)); Kapoor, V.B. (Indian Inst. of Petroleum, Dehradun (India)); Vishnoi, S.C. (Indian Inst. of Petroleum, Dehradun (India)); Bhagat, S.D. (Indian Inst. of Petroleum, Dehradun (India))

    1994-06-01

    A simple gas chromatographic (GC) procedure has been developed to estimate the individual alkylated phenols used as antioxidants to improve the shelf life of fuels and lubricants. Preparative gas chromatography was applied for separation and collection in sufficient quantity of the isomers of tertiary butyl, octyl and dodecyl phenols prepared by catalytic alkylation of phenol with isobutylene or its oligomers. The separated fractions were characterised by Infra-red spectrometry (IR) and paper chromatography. Out of several GC columns studies, a high resolution capillary column of 100% Methyl, Silicone gum (SE-30) as stationary phase gave best results. Data generated on various packed and capillary columns are in good agreement. (orig.)

  19. Capillary pericytes regulate cerebral blood flow in health and disease

    DEFF Research Database (Denmark)

    Hall, Catherine N; Reynell, Clare; Gesslein, Bodil

    2014-01-01

    that neuronal activity and the neurotransmitter glutamate evoke the release of messengers that dilate capillaries by actively relaxing pericytes. Dilation is mediated by prostaglandin E2, but requires nitric oxide release to suppress vasoconstricting 20-HETE synthesis. In vivo, when sensory input increases......Increases in brain blood flow, evoked by neuronal activity, power neural computation and form the basis of BOLD (blood-oxygen-level-dependent) functional imaging. Whether blood flow is controlled solely by arteriole smooth muscle, or also by capillary pericytes, is controversial. We demonstrate...

  20. Laser–capillary interaction for the EXIN project

    Energy Technology Data Exchange (ETDEWEB)

    Bisesto, F.G., E-mail: fabrizio.giuseppe.bisesto@lnf.infn.it [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Sapienza – University of Rome, P.le Aldo Moro, 2, 00185 Rome (Italy); Anania, M.P. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Bacci, A.L. [INFN – Milano, Via Celoria 16, 20133 Milan (Italy); Bellaveglia, M.; Chiadroni, E. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Cianchi, A. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Universit degli studi di Roma Tor Vergata, Via di Tor Vergata, Rome (Italy); Curcio, A. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Sapienza – University of Rome, P.le Aldo Moro, 2, 00185 Rome (Italy); Di Giovenale, D.; Di Pirro, G.; Ferrario, M.; Galletti, M.; Gallo, A.; Ghigo, A. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Marocchino, A.; Mostacci, A.; Petrarca, M. [Sapienza – University of Rome, P.le Aldo Moro, 2, 00185 Rome (Italy); INFN – Roma1, P.le Aldo Moro, 2, 00185 Rome (Italy); Pompili, R. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy); Rossi, A.R.; Serafini, L. [INFN – Milano, Via Celoria 16, 20133 Milan (Italy); Vaccarezza, C. [INFN-LNF, Via Enrico Fermi 40, 00044 Frascati (Italy)

    2016-09-01

    The EXIN project is under development within the SPARC-LAB facility of the National Laboratory of Frascati (LNF-INFN). This project aims to accelerate pre-existing electron bunches with high brightness by exploiting the wakefield plasma acceleration technique, while preserving the initial brightness. The wakefield is excited inside a dielectric capillary by high intensity laser pulses produced by the FLAME laser interacting with a gas. In this work, we present numerical simulations in order to optimize energy coupling between our laser with super-Gaussian transverse profile and a dielectric capillary. Moreover, an overview of the experimental layout will be given.

  1. A novel ionic liquids grafted polysiloxane for capillary gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Qing Quan Wei; Mei Ling Qi; Ruo Nong Fu

    2009-01-01

    A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography(CGC)is described.The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane(PMHS-[VHIm][PF6])was synthesized,characterized and coated onto capillary columns by static coating.The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks.The present work suggests that novel stationary phase has a great potential for further development and application.

  2. Development of a Contingency Capillary Wastewater Management Device

    Science.gov (United States)

    Thomas, Evan A.

    2010-01-01

    The Personal Body .Attached Liquid Liquidator (PBALL) is conceived as a passive, capillary driven contingency wastewater disposal device. In this contingency scenario, the airflow system on the NASA Crew Exploration Vehicle (CEV) is assumed to have failed, leaving only passive hardware and vacuum vent to dispose of the wastewater. To meet these needs, the PBALL was conceived to rely on capillary action and urine wetting design considerations. The PBALL is designed to accommodate a range of wetting conditions, from 0deg wastewater to vacuum while minimizing cabin air loss. A sub-scale PBALL test article was demonstrated on NASA's reduced gravity aircraft in April, 2010.

  3. Combining ligation reaction and capillary gel electrophoresis to obtain reliable long DNA probes.

    Science.gov (United States)

    García-Cañas, Virginia; Mondello, Monica; Cifuentes, Alejandro

    2011-05-01

    New DNA amplification methods are continuously developed for sensitive detection and quantification of specific DNA target sequences for, e.g. clinical, environmental or food applications. These new applications often require the use of long DNA oligonucleotides as probes for target sequences hybridization. Depending on the molecular technique, the length of DNA probes ranges from 40 to 450 nucleotides, solid-phase chemical synthesis being the strategy generally used for their production. However, the fidelity of chemical synthesis of DNA decreases for larger DNA probes. Defects in the oligonucleotide sequence result in the loss of hybridization efficiency, affecting the sensitivity and selectivity of the amplification method. In this work, an enzymatic procedure has been developed as an alternative to solid-phase chemical synthesis for the production of long oligonucleotides. The enzymatic procedure for probe production was based on ligation of short DNA sequences. Long DNA probes were obtained from smaller oligonucleotides together with a short sequence that acts as bridge stabilizing the molecular complex for DNA ligation. The ligation reactions were monitored by capillary gel electrophoresis with laser-induced fluorescence detection (CGE-LIF) using a bare fused-silica capillary. The capillary gel electrophoresis-LIF method demonstrated to be very useful and informative for the characterization of the ligation reaction, providing important information about the nature of some impurities, as well as for the fine optimization of the ligation conditions (i.e. ligation cycles, oligonucleotide and enzyme concentration). As a result, the yield and quality of the ligation product were highly improved. The in-lab prepared DNA probes were used in a novel multiplex ligation-dependent genome amplification (MLGA) method for the detection of genetically modified maize in samples. The great possibilities of the whole approach were demonstrated by the specific and sensitive

  4. Reverse capillary flow of condensed water through aligned multiwalled carbon nanotubes

    Science.gov (United States)

    Yun, Jongju; Jeon, Wonjae; Alam Khan, Fakhre; Lee, Jinkee; Baik, Seunghyun

    2015-06-01

    Molecular transport through nanopores has recently received considerable attention as a result of advances in nanofabrication and nanomaterial synthesis technologies. Surprisingly, water transport investigations through carbon nanochannels resulted in two contradicting observations: extremely fast transport or rejection of water molecules. In this paper, we elucidate the mechanism of impeded water vapor transport through the interstitial space of aligned multiwalled carbon nanotubes (aligned-MWCNTs)—capillary condensation, agglomeration, reverse capillary flow, and removal by superhydrophobicity at the tip of the nanotubes. The origin of separation comes from the water’s phase change from gas to liquid, followed by reverse capillary flow. First, the saturation water vapor pressure is decreased in a confined space, which is favorable for the phase change of incoming water vapor into liquid drops. Once continuous water meniscus is formed between the nanotubes by the adsoprtion and agglomeration of water molecules, a high reverse Laplace pressure is induced in the mushroom-shaped liquid meniscus at the entry region of the aligned-MWCNTs. The reverse Laplace pressure can be significantly enhanced by decreasing the pore size. Finally, the droplets pushed backward by the reverse Laplace pressure can be removed by superhydrophobicity at the tip of the aligned-MWCNTs. The analytical analysis was also supported by experiments carried out using 4 mm-long aligned-MWCNTs with different intertube distances. The water rejection rate and the separation factor increased as the intertube distance decreased, resulting in 90% and 10, respectively, at an intertube distance of 4 nm. This mechanism and nanotube membrane may be useful for energy-efficient water vapor separation and dehumidification.

  5. Normal human epithelial cells regulate the size and morphology of tissue-engineered capillaries.

    Science.gov (United States)

    Rochon, Marie-Hélène; Fradette, Julie; Fortin, Véronique; Tomasetig, Florence; Roberge, Charles J; Baker, Kathleen; Berthod, François; Auger, François A; Germain, Lucie

    2010-05-01

    The survival of thick tissues/organs produced by tissue engineering requires rapid revascularization after grafting. Although capillary-like structures have been reconstituted in some engineered tissues, little is known about the interaction between normal epithelial cells and endothelial cells involved in the in vitro angiogenic process. In the present study, we used the self-assembly approach of tissue engineering to examine this relationship. An endothelialized tissue-engineered dermal substitute was produced by adding endothelial cells to the tissue-engineered dermal substitute produced by the self-assembly approach. The latter consists in culturing fibroblasts in the medium supplemented with serum and ascorbic acid. A network of tissue-engineered capillaries (TECs) formed within the human extracellular matrix produced by dermal fibroblasts. To determine whether epithelial cells modify TECs, the size and form of TECs were studied in the endothelialized tissue-engineered dermal substitute cultured in the presence or absence of epithelial cells. In the presence of normal keratinocytes from skin, cornea or uterine cervix, endothelial cells formed small TECs (cross-sectional area estimated at less than 50 microm(2)) reminiscent of capillaries found in the skin's microcirculation. In contrast, TECs grown in the absence of epithelial cells presented variable sizes (larger than 50 microm(2)), but the addition of keratinocyte-conditioned media or exogenous vascular endothelial growth factor induced their normalization toward a smaller size. Vascular endothelial growth factor neutralization inhibited the effect of keratinocyte-conditioned media. These results provide new direct evidence that normal human epithelial cells play a role in the regulation of the underlying TEC network, and advance our knowledge in tissue engineering for the production of TEC networks in vitro.

  6. Capillary growth, ultrastructure remodeling and exercise training in skeletal muscle of essential hypertensive patients

    DEFF Research Database (Denmark)

    Gliemann, Lasse; Buess, Rahel; Nyberg, Michael Permin

    2015-01-01

    AIM: The aim was to elucidate whether essential hypertension is associated with altered capillary morphology and density and to what extend exercise training can normalize these parameters. METHODS: To investigate angiogenesis and capillary morphology in essential hypertension, muscle biopsies we...

  7. A fully automated 384 capillary array for DNA sequencer. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qingbo; Kane, T

    2003-03-20

    Phase I SpectruMedix has successfully developed an automatic 96-capillary array DNA prototype based on the multiplexed capillary electrophoresis system originated from Ames Laboratory-USDOE, Iowa State University. With computer control of all steps involved in a 96-capillary array running cycle, the prototype instrument (the SCE9600) is now capable of sequencing 450 base pairs (bp) per capillary, or 48,000 bp per instrument run within 2 hrs. Phase II of this grant involved the advancement of the core 96 capillary technologies, as well as designing a high density 384 capillary prototype. True commercialization of the 96 capillary instrument involved finalization of the gel matrix, streamlining the instrument hardware, creating a more reliable capillary cartridge, and further advancement of the data processing software. Together these silos of technology create a truly commercializable product (the SCE9610) capable of meeting the operation needs of the sequencing centers.

  8. Multiple-capillary measurement of RBC speed, flux, and density with optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2013-11-01

    As capillaries exhibit heterogeneous and fluctuating dynamics even during baseline, a technique measuring red blood cell (RBC) speed and flux over many capillaries at the same time is needed. Here, we report that optical coherence tomography can capture individual RBC passage simultaneously over many capillaries located at different depths. Further, we demonstrate the ability to quantify RBC speed, flux, and linear density. This technique will provide a means to monitor microvascular flow dynamics over many capillaries at different depths at the same time.

  9. Preparation of polyacrylamide gel-filled capillaries with step gradients and low UV-detection background

    Institute of Scientific and Technical Information of China (English)

    陈义

    1997-01-01

    Polyacrylamide- filled capillaries with step gradients were designed and prepared with a newly established method,which is also suitable for producing other sorts of capillaries.The resulting capillaries allow the use of any UV light to approach the most sensitive detection and have the features of fast running speed and high separation efficiency In addition,the capillaries can he used continuously for more than two weeks.

  10. New Sorbent for Bilirubin Removal from Human Plasma: Albumin Immobilized Microporous Membranous PTFE Capillaries

    Institute of Scientific and Technical Information of China (English)

    Lei ZHANG; Gu JIN

    2005-01-01

    In this study, we developed a tailored capillary sorbent for bilirubin removal. For immobilized bioligand, capillaries were grafted with epoxy groups using RIGP. The HSA immobilized capillaries has a high affinity adsorption capacity (71.2 mg bilirubin/g polymer) and a shorter adsorption equilibrium time (about 60 min).

  11. Cortical capillary dysfunction in patients suspected of Alzheimer’s disease

    DEFF Research Database (Denmark)

    Eskildsen, Simon Fristed; Gyldensted, Louise; Nagenthiraja, Kartheeban

    Vascular risk factors are suspected to play a role in the etiology of Alzheimer’s disease. Recently, a model that relates capillary dysfunction to the development of AD was proposed[1]. The model predicts that capillary dysfunction in form of increased capillary transit time heterogeneity (CTH...

  12. Effects of Capillary Forces and Adsorption on Reserves Distribution

    DEFF Research Database (Denmark)

    Shapiro, Alexander; Stenby, Erling Halfdan

    1996-01-01

    The purpose of this study is to evaluate the effects of capillary forces and adsorption on the distribution of a hydrocarbon mixture in an oil-gas-condensate reservoir. These effects consist in the precipitation of the liquid phase in thin pores and on the internal surface of the reservoir rock...

  13. CAPILLARY ISOELECTRIC FOCUSING (CIEF) FOR THE CHARACTERIZATION OF HUMIC SUBSTANCES

    Science.gov (United States)

    Preparative solution isoelectric focusing was used to fractionate 50 mg of a soil fulvic acid (FA); the harvested fractions were characterized with UV-Vis spectroscopy, gel permeation chromatography and capillary zone electrophoresis (CZE) and showed a distribution in the created...

  14. Computer modeling of capillary flow with superimposed pulsations

    Science.gov (United States)

    Yaganova, A. E.; Marfin, E. A.

    2016-11-01

    Increasing efficiency of methods of oil production can be achieved by the influence of elastic vibrations. It is a well-known fact that shift viscosity of oil changes under the effect of elastic vibrations. This change depends on properties of the oil and exposure mode. Existing approaches to the research of the way wave exposure impacts on viscosity are based on measuring it after the processing. This article concerns development of methods to measure viscosity of liquid right during its exposure to elastic vibrations. The suggested approach is based on combining numerical and natural experiments. We investigated the pulsating flow of viscid liquid in a capillary numerically in this article. We received allocations of fields of average velocity and pressure in a capillary. It is demonstrated that imposed pulsations in a capillary do not impact on hydrodynamics of the flow. We offered the scheme of an experimental installation for a research of the impact that wave exposure has on the viscosity of liquids. The installation is based on a capillary viscometer.

  15. Revisiting the Diffusion Problem in a Capillary Tube Geometry

    CERN Document Server

    Sullivan, Eric

    2012-01-01

    The present work revisits the problem of modeling diffusion above a stagnant liquid interface in a capillary tube geometry. In this revisitation we elucidate a misconception found in the classical model proposed by Bird et. al. Furthermore, we propose alternative explanations for thermally forced diffusion and provide a description of natural convection in the absence of forcing terms.

  16. Atomic-scale friction : thermal effects and capillary condensation

    NARCIS (Netherlands)

    Jinesh, Kochupurackal Balakrishna Pillai

    2006-01-01

    This work entitled as "Atomic-scale friction: thermal effects and capillary condensation" is a study on the fundamental aspects of the origin of friction from the atomic-scale. We study two realistic aspects of atomic-scale friction, namely the effect of temperature and the effect of relative humidi

  17. Pathogenetics of alveolar capillary dysplasia with misalignment of pulmonary veins

    NARCIS (Netherlands)

    Szafranski, P.; Gambin, T.; Dharmadhikari, A.V.; Akdemir, K.C.; Jhangiani, S.N.; Schuette, J.; Godiwala, N.; Yatsenko, S.A.; Sebastian, J.; Madan-Khetarpal, S.; Surti, U.; Abellar, R.G.; Bateman, D.A.; Wilson, A.L.; Markham, M.H.; Slamon, J.; Santos-Simarro, F.; Palomares, M.; Nevado, J.; Lapunzina, P.; Chung, B.H.; Wong, W.L.; Chu, Y.W.; Mok, G.T.; Kerem, E.; Reiter, J.; Ambalavanan, N.; Anderson, S.A.; Kelly, D.R.; Shieh, J.; Rosenthal, T.C.; Scheible, K.; Steiner, L.; Iqbal, M.A.; McKinnon, M.L.; Hamilton, S.J.; Schlade-Bartusiak, K.; English, D.; Hendson, G.; Roeder, E.R.; DeNapoli, T.S.; Littlejohn, R.O.; Wolff, D.J.; Wagner, C.L.; Yeung, A.; Francis, D.; Fiorino, E.K.; Edelman, M.; Fox, J.; Hayes, D.A.; Janssens, S.; Baere, E. De; Menten, B.; Loccufier, A.; Vanwalleghem, L.; Moerman, P.; Sznajer, Y.; Lay, A.S.; Kussmann, J.L.; Chawla, J.; Payton, D.J.; Phillips, G.E.; Brosens, E.; Tibboel, D.; Klein, A.; Maystadt, I.; Fisher, R.; Sebire, N.; Male, A.; Chopra, M.; Pinner, J.; Malcolm, G.; Peters, G.; Arbuckle, S.; Lees, M.; Mead, Z.; Quarrell, O.; Sayers, R.; Owens, M.; Shaw-Smith, C.; Lioy, J.; McKay, E.; Leeuw, N. de; Feenstra, I.; Spruijt, L.; Elmslie, F.; Thiruchelvam, T.; Bacino, C.A.; Langston, C.; Lupski, J.R.; Sen, P.; Popek, E.; Stankiewicz, P.

    2016-01-01

    Alveolar capillary dysplasia with misalignment of pulmonary veins (ACDMPV) is a lethal lung developmental disorder caused by heterozygous point mutations or genomic deletion copy-number variants (CNVs) of FOXF1 or its upstream enhancer involving fetal lung-expressed long noncoding RNA genes LINC0108

  18. Use of a fluorosurfactant in micellar electrokinetic capillary chromatography.

    Science.gov (United States)

    de Ridder, R; Damin, F; Reijenga, J; Chiari, M

    2001-05-04

    A fluorosurfactant, the anionic N-ethyl-N-[(heptadecafluorooctyl)sulfonyl]glycine potassium salt, trade name FC-129 [CAS 2991-51-7] was investigated for possible application in micellar electrokinetic capillary chromatography (MEKC). The surfactant was characterized with conductometric titration and test sample mixtures were investigated in MEKC systems, and compared with sodium dodecylsulphate. An increased efficiency and interesting selectivity differences were observed.

  19. Regulation of skeletal muscle capillary growth in exercise and disease.

    Science.gov (United States)

    Haas, Tara L; Nwadozi, Emmanuel

    2015-12-01

    Capillaries, which are the smallest and most abundant type of blood vessel, form the primary site of gas, nutrient, and waste transfer between the vascular and tissue compartments. Skeletal muscle exhibits the capacity to generate new capillaries (angiogenesis) as an adaptation to exercise training, thus ensuring that the heightened metabolic demand of the active muscle is matched by an improved capacity for distribution of gases, nutrients, and waste products. This review summarizes the current understanding of the regulation of skeletal muscle capillary growth. The multi-step process of angiogenesis is coordinated through the integration of a diverse array of signals associated with hypoxic, metabolic, hemodynamic, and mechanical stresses within the active muscle. The contributions of metabolic and mechanical factors to the modulation of key pro- and anti-angiogenic molecules are discussed within the context of responses to a single aerobic exercise bout and short-term and long-term training. Finally, the paradoxical lack of angiogenesis in peripheral artery disease and diabetes and the implications for disease progression and muscle health are discussed. Future studies that emphasize an integrated analysis of the mechanisms that control skeletal muscle capillary growth will enable development of targeted exercise programs that effectively promote angiogenesis in healthy individuals and in patient populations.

  20. Dynamics of capillary self-alignment for mesoscopic foil devices

    NARCIS (Netherlands)

    Arutinov, G.; Mastrangeli, M.; Smits, E.C.P.; Schoo, H.F.M.; Brugger, J.; Dietzel, A.H.

    2013-01-01

    We report experimental evidence for three sequential, distinct dynamic regimes in the capillary self-alignment of centimeter-sized foil dies released at large uniaxial offsets from equilibrium. We show that the initial transient wetting regime, along with inertia and wetting properties of the dies,