WorldWideScience

Sample records for nonlinear laser diagnostic

  1. Prospects for Nonlinear Laser Diagnostics in the Jet Noise Laboratory

    Science.gov (United States)

    Herring, Gregory C.; Hart, Roger C.; Fletcher, mark T.; Balla, R. Jeffrey; Henderson, Brenda S.

    2007-01-01

    Two experiments were conducted to test whether optical methods, which rely on laser beam coherence, would be viable for off-body flow measurement in high-density, compressible-flow wind tunnels. These tests measured the effects of large, unsteady density gradients on laser diagnostics like laser-induced thermal acoustics (LITA). The first test was performed in the Low Speed Aeroacoustics Wind Tunnel (LSAWT) of NASA Langley Research Center's Jet Noise Laboratory (JNL). This flow facility consists of a dual-stream jet engine simulator (with electric heat and propane burners) exhausting into a simulated flight stream, reaching Mach numbers up to 0.32. A laser beam transited the LSAWT flow field and was imaged with a high-speed gated camera to measure beam steering and transverse mode distortion. A second, independent test was performed on a smaller laboratory jet (Mach number < 1.2 and mass flow rate < 0.1 kg/sec). In this test, time-averaged LITA velocimetry and thermometry were performed at the jet exit plane, where the effect of unsteady density gradients is observed on the LITA signal. Both experiments show that LITA (and other diagnostics relying on beam overlap or coherence) faces significant hurdles in the high-density, compressible, and turbulent flow environments similar to those of the JNL.

  2. Lasers for nonlinear microscopy.

    Science.gov (United States)

    Wise, Frank

    2013-03-01

    Various versions of nonlinear microscopy are revolutionizing the life sciences, almost all of which are made possible because of the development of ultrafast lasers. In this article, the main properties and technical features of short-pulse lasers used in nonlinear microscopy are summarized. Recent research results on fiber lasers that will impact future instruments are also discussed.

  3. Pulsed Blue and Ultraviolet Laser System for Fluorescence Diagnostics based on Nonlinear Frequency Conversion

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay

    nm laser is non-trivial. Detailed investigation into pump beam optimization has been carried out for an end-pumped 946 nm CW laser. Using an innovative external cavity tapered diode laser as pump source, a record 800 mW of output power was obtained using a single-emitter diode laser pump source....... The spatial and spectral properties of the pump source were also investigated individually, and it was concluded that a broad spectrum tapered diode pump source may be most stable and cost-effective. To generate high peak power pulsed output, Q-switched lasers were considered. In particular, synchronized Q...... a four-sigma or six-sigma definition was used. Detailed investigation into the relative timing jitter between the two synchronized pulses was also carried out, where it was found that the lower limit on the relative jitter, determined by pump power fluctuations and amplified spontaneous emission, was 6...

  4. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  5. ORION laser target diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K. [Plasma Physics Department, Atomic Weapons Establishment, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); and others

    2012-10-15

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  6. Beamlet laser diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Burkhart, S.C.; Behrendt, W.C.; Smith, I.

    1996-06-01

    Beamlet is instrumented extensively to monitor the performance of the overall laser system and many of its subsystems. Beam diagnostics, installed in key locations, are used to fully characterize the beam during its propagation through the multipass cavity and the laser`s output section. This article describes the diagnostics stations located on Beamlet and discusses the design, calibration, and performance of the Beamlet calorimeters. The authors used Nova`s diagnostics packages to develop the Beamlet design to determine beam energy, spatial profile, temporal profile, and other beam parameters. Technologic improvements within the last several years in controls, charge-coupled device (CCD) cameras, and fast oscilloscopes have allowed the authors to obtain more accurate measurements on the Beamlet laser system. They briefly cover some of these techniques, including a description of their LabVIEW based data acquisition system.

  7. Industrial applications of laser diagnostics

    CERN Document Server

    Deguchi, Yoshihiro

    2011-01-01

    Tighter regulations of harmful substances such as NOx, CO, heavy metals, particles, emissions from commercial plants and automobiles reflect a growing demand for lowering the anthropogenic burdens on the environment. It is equally important to monitor controlling factors to improve the operation of industrial machinery and plants. Among the many methods for doing this, laser diagnostics stands out. Taking a practical approach, Industrial Applications of Laser Diagnostics discusses how to apply laser diagnostics to engines, gas turbines, thermal and chemical plant systems, and disposal faciliti

  8. Laser Diagnostics for Spacecraft Propulsion

    Science.gov (United States)

    2015-10-13

    AFTC/PA Clearance No. XXXX 8 Ion Engines & Hall Thrusters Operation Ion engines and Hall thrusters are electrostatic propulsion devices • Ion Engines... Hall thrusters are gridless electrostatic thrusters – Propellant ionized by electrons trapped in magnetic field – Ions accelerated by an electric field...Briefing Charts 3. DATES COVERED (From - To) 21 September 2015 – 13 October 2015 4. TITLE AND SUBTITLE Laser Diagnostics for Spacecraft Propulsion 5a

  9. Laser And Nonlinear Optical Materials For Laser Remote Sensing

    Science.gov (United States)

    Barnes, Norman P.

    2005-01-01

    NASA remote sensing missions involving laser systems and their economic impact are outlined. Potential remote sensing missions include: green house gasses, tropospheric winds, ozone, water vapor, and ice cap thickness. Systems to perform these measurements use lanthanide series lasers and nonlinear devices including second harmonic generators and parametric oscillators. Demands these missions place on the laser and nonlinear optical materials are discussed from a materials point of view. Methods of designing new laser and nonlinear optical materials to meet these demands are presented.

  10. Combustion & Laser Diagnostics Research Complex (CLDRC)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: The Combustion and Laser Diagnostics Research Complex (CLRDC) supports the experimental and computational study of fundamental combustion phenomena to...

  11. Nonlinear frequency shift in Raman backscattering and its implications for plasma diagnostics

    Science.gov (United States)

    Kaganovich, D.; Hafizi, B.; Palastro, J. P.; Ting, A.; Helle, M. H.; Chen, Y.-H.; Jones, T. G.; Gordon, D. F.

    2016-12-01

    Raman backscattered radiation of intense laser pulses in plasmas is investigated for a wide range of intensities relevant to laser wakefield acceleration. The weakly nonlinear dispersion relation for Raman backscattering predicts an intensity and density dependent frequency shift that is opposite to that suggested by a simple relativistic consideration. This observation has been benchmarked against experimental results, providing a novel diagnostic for laser-plasma interactions.

  12. Nonlinear Frequency Shift in Raman Backscattering and its Implications for Plasma Diagnostics

    CERN Document Server

    Kaganovich, D; Palastro, J P; Ting, A; Helle, M H; Chen, Y -H; Jones, T G; Gordon, D F

    2016-01-01

    Raman backscattered radiation of intense laser pulses in plasma is investigated for a wide range of intensities relevant to laser wakefield acceleration. The weakly nonlinear dispersion relation for Raman backscattering predicts an intensity and density dependent frequency shift that is opposite to that suggested by a simple relativistic consideration. This observation has been benchmarked against experimental results, providing a novel diagnostic for laser-plasma interactions.

  13. Extreme nonlinear optics and laser damage

    Science.gov (United States)

    Maldutis, Evaldas

    2010-11-01

    The study of laser induced damage threshold caused by series of identical laser pulses (LID-T-N) on gamma radiation resistant glasses and their analogs is performed applying know-how ultra stable laser radiation. The presented results and analysis of earlier received results show that nonlinear optical phenomena in extreme conditions of interaction are different from the traditional nonlinear optical processes, because they depend not only on intensity of electromagnetic field of laser radiation, but also on the pulse number in series of identical laser pulses. This range of laser intensities is not wide; it is different for each material and determines the range of Extreme Nonlinear Optics. The dependence of LID-T-N on pulse number N for different kinds of high quality transparent glasses was observed. The study of dynamics of these processes (i.e. the study of dependence on N) at different intensities in series of incident laser pulses provides new information about properties of the materials useful for studying laser damage fundamentals and their application. The expectation that gamma radiation resistant glasses could give useful information for technology of resistant optics for high power lasers has not proved. The received results well correspond with the earlier proposed model of laser damage.

  14. Nonlinear frequency conversion in fiber lasers

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian

    The concept of nonlinear frequency conversion entails generating light at new frequencies other than those of the source light. The emission wavelength of typical fiber laser systems, relying on rare-earth dopants, are constrained within specific bands of the infrared region. By exploiting...... nonlinear processes, light from these specific wavelength bands can be used to generate light at new frequencies otherwise not obtainable by rare-earth elements. This thesis describes work covering Raman fiber lasers (RFLs) and amplifiers for nonlinear frequency down-conversion, and also the method...

  15. Review of laser diagnostics at the Vulcan laser facility

    Institute of Scientific and Technical Information of China (English)

    Ian Musgrave; Marco Galimberti; Alexis Boyle; Cristina Hernandez-Gomez; Andrew Kidd; Bryn Parry; Dave Pepler; Trevor Winstone; John Collier

    2015-01-01

    In this paper we review the provision of the laser diagnostics that are installed on the Vulcan laser facility. We will present strategies for dealing with the energy of high energy systems and with ways of handling the beam sizes of the lasers. We present data captured during typical experimental campaigns to demonstrate their reliability and variation in shot to shot values.

  16. Effect of gain nonlinearity in semiconductor lasers

    DEFF Research Database (Denmark)

    Jensen, Niels H.; Christiansen, Peter Leth; Skovgaard, Ove

    1988-01-01

    Semiconductor lasers are modeled by single-mode rate equations with Langevin noise terms and the influence of nonlinear gain is investigated. For cw operation the probability distribution for the carrier number and the photon number in the laser cavity is obtained. The corresponding (2......+1)-dimensional Fokker-Planck equation is derived and integrated on an Amdahl VP1100 vector processor. Above threshold the resulting probability density agrees with the rate-equation predictions. The case of high-speed modulation is also considered. The nonlinear gain is found to stabilize the laser....

  17. Laser and nonlinear optical materials

    Energy Technology Data Exchange (ETDEWEB)

    De Shazer, L.G.

    1986-01-01

    This book contains 21 papers. Some of the titles are: Frequency conversion materials from a device perspective; Recent developments in area; Recent developments in barium borate; Growth of laser crystals at Airtron; Crystal growth and the future of solid state lasers; Faraday rotator materials for laser systems; and Mechanical properties of single crystal ceramics.

  18. Diagnostics of laser ablated plasma plumes

    DEFF Research Database (Denmark)

    Amoruso, S.; Toftmann, B.; Schou, Jørgen;

    2004-01-01

    The effect of an ambient gas on the expansion dynamics of laser ablated plasmas has been studied for two systems by exploiting different diagnostic techniques. First, the dynamics of a MgB2 laser produced plasma plume in an Ar atmosphere has been investigated by space-and time-resolved optical...

  19. Nova alignment and laser diagnostics systems - 1

    Energy Technology Data Exchange (ETDEWEB)

    Bliss, E.S.; Ozarski, R.G.; Myers, D.W.; Richards, J.B.; Swift, C.D.; Boyd, R.D.; Hugenberger, R.E.; Seppala, L.G.; Parker, J.; Dryden, E.H.

    1981-01-01

    The alignment and laser diagnostic systems guide laser pulses through the separate amplifier chains to the target, measure their temporal, spatial and energy characteristics, and ensure simultaneous arrival at the target to within 5 picoseconds. Alignment tasks accomplished prior to each target shot involve automatic or remote-manual adjustments of approximately 2000 stepper motors and other actuators for the full 20 beam, 3 wavelength system. The primary detectors for alignment functions are CCD cameras with both digital and standard video output. Diagnostic data handling and processing is accomplished digitally, and both the alignment and diagnostic systems are integrated into the facility-wide digital control network.

  20. Laser Diagnostics for Reacting Flows

    Science.gov (United States)

    2010-01-11

    absorption diagnostic for vapor-phase measurements in an evaporating n-decane aerosol,” Appied Physics B. 97, 215-225, (2009). 30. J.M. Porter, J.B...fluorescence of toluene for time- resolved imaging of gaseous flows,” Appied Physics B, 2010, in press. 35. J.M. Porter, J.B. Jeffries and R.K. Hanson

  1. Auto-identifying Diagnostic Symptom of Nonlinear Vibration

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The technology of diagnostic symptom identification of nonlinear vibration is based on a database of a diagnostic case. This paper defines the periodic degree, quasi-periodic degree, and chaotic degree of a Poincare map, an iterated map, and adopts the image-identification theory, so the three states of periodic, quasi-periodic, and chaotic running states of a machine can be distinguished. It also defines the variable identity, rotating angle and spread degree. The database of diagnostic case is expressed by means of an access database. The diagnostic symptoms are identified using the difference between the Poincare maps of samples and the fault-case. Finally, we demonstrate an identification system of a nonlinear vibration diagnostic symptom of large rotating machinery.

  2. Dichroic beamsplitter for high energy laser diagnostics

    Science.gov (United States)

    LaFortune, Kai N; Hurd, Randall; Fochs, Scott N; Rotter, Mark D; Hackel, Lloyd

    2011-08-30

    Wavefront control techniques are provided for the alignment and performance optimization of optical devices. A Shack-Hartmann wavefront sensor can be used to measure the wavefront distortion and a control system generates feedback error signal to optics inside the device to correct the wavefront. The system can be calibrated with a low-average-power probe laser. An optical element is provided to couple the optical device to a diagnostic/control package in a way that optimizes both the output power of the optical device and the coupling of the probe light into the diagnostics.

  3. Optical diagnostics of femtosecond laser plasmas

    Institute of Scientific and Technical Information of China (English)

    李玉同; 张杰; 陈黎明; 夏江帆; 腾浩; 赵理曾; 林景全; 李英骏; 魏志义; 王龙; 江文勉

    2001-01-01

    Optical diagnostics of evolution of plasmas produced by ultrashort laser pulses is carried out using a femtosecond probing beam. The time sequence of plasma shadowgrams and interferograms are obtained. The filamentation instability in high_density region induces the local density modification. Large_scale toroidal magnetic fields confine plasma expansion in the transverse direction, resulting in the formation of a plasma jet. The plasma expansion along the target normal direction is found to scale as 1 2.

  4. 2009 Laser Diagnostics in Combustion GRC

    Energy Technology Data Exchange (ETDEWEB)

    Volker Sick

    2009-08-16

    Non-intrusive laser diagnostics for the spatially and temporally resolved measurement of temperature, chemical composition, and flow parameters have emerged over the last few decades as major tools for the study of both fundamental and applied combustion science. Many of the important advances in the field can be attributed to the discussions and ideas emanating from this meeting. This conference, originating in 1981 and held biennially, focuses on laser-based methods for measurement of both macroscopic parameters and the underlying microscale physical and chemical processes. Applications are discussed primarily to elucidate new chemical and physical issues and/or interferences that need to be addressed to improve the accuracy and precision of the various diagnostic approaches or to challenge the community of diagnosticians to invent new measurement techniques. Combustion environments present special challenges to the optical diagnostics community as they address measurements relevant to turbulence, spray and mixture formation, or turbulence/chemistry interactions important in practical combustion systems as well as fundamental chemical reactions in stationary laminar flames. The diagnostics considered may be generally classed as being incoherent, where the signals are radiated isotropically, or coherent, where the signals are generated in a directed, beam-like fashion. Both of the foregoing may employ either electronic or Raman resonance enhancement or a combination of both. Prominent incoherent approaches include laser induced fluorescence (LIF), spontaneous Raman scattering, Rayleigh scattering, laser induced incandescence, molecular flow tagging, and Mie scattering and their two- and three-dimensional imaging variants. Coherent approaches include coherent anti-Stokes Raman scattering (CARS), degenerate four wave mixing (DFWM), polarization spectroscopy (PS), laser induced grating spectroscopy (LIGS) and laser-based absorption spectroscopy. Spectroscopic

  5. 2009 Laser Diagnostics in Combustion GRC

    Energy Technology Data Exchange (ETDEWEB)

    Sick, Volker [Univ. of Michigan, Ann Arbor, MI (United States)

    2009-08-16

    Non-intrusive laser diagnostics for the spatially and temporally resolved measurement of temperature, chemical composition, and flow parameters have emerged over the last few decades as major tools for the study of both fundamental and applied combustion science. Many of the important advances in the field can be attributed to the discussions and ideas emanating from this meeting. This conference, originating in 1981 and held biennially, focuses on laser-based methods for measurement of both macroscopic parameters and the underlying microscale physical and chemical processes. Applications are discussed primarily to elucidate new chemical and physical issues and/or interferences that need to be addressed to improve the accuracy and precision of the various diagnostic approaches or to challenge the community of diagnosticians to invent new measurement techniques. Combustion environments present special challenges to the optical diagnostics community as they address measurements relevant to turbulence, spray and mixture formation, or turbulence/chemistry interactions important in practical combustion systems as well as fundamental chemical reactions in stationary laminar flames. The diagnostics considered may be generally classed as being incoherent, where the signals are radiated isotropically, or coherent, where the signals are generated in a directed, beam-like fashion. Both of the foregoing may employ either electronic or Raman resonance enhancement or a combination of both. Prominent incoherent approaches include laser induced fluorescence (LIF), spontaneous Raman scattering, Rayleigh scattering, laser induced incandescence, molecular flow tagging, and Mie scattering and their two- and three-dimensional imaging variants. Coherent approaches include coherent anti-Stokes Raman scattering (CARS), degenerate four wave mixing (DFWM), polarization spectroscopy (PS), laser induced grating spectroscopy (LIGS) and laser-based absorption spectroscopy. Spectroscopic

  6. Case-Deletion Diagnostics for Nonlinear Structural Equation Models

    Science.gov (United States)

    Lee, Sik-Yum; Lu, Bin

    2003-01-01

    In this article, a case-deletion procedure is proposed to detect influential observations in a nonlinear structural equation model. The key idea is to develop the diagnostic measures based on the conditional expectation of the complete-data log-likelihood function in the EM algorithm. An one-step pseudo approximation is proposed to reduce the…

  7. Laser Wakefield diagnostic using holographic longitudinal interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Volfbeyn, P.; Esarey, E.; Leemans, W.P.

    1999-03-26

    We propose a diagnostic technique for wakefield measurement in plasma channels. A new technique for plasma channel creation, the Ignitor Heater scheme was proposed and experimentally tested in hydrogen and nitrogen previously. It makes use of two laser pulses. The Ignitor, an ultrashort (sub 100 fs) laser pulse, is brought to a line focus using a cylindrical lens to ionize the gas. The Heater pulse (160 ps long) is used to heat the existing spark via in-verse Bremsstrahlung. The hydrodynamic shock expansion creates a partially evacuated plasma channel with a density minimum on axis. Such a channel has properties of an optical waveguide. This technique allows creation of plasma channels in low atomic number gases, such as hydrogen, which is of importance for guiding of highly intense laser pulses. Laser pulses injected into such plasma channels produce a plasma wake that has a phase velocity close to the speed of light. A discussion of plasma wake measurements, using a Longitudinal Interferometry Wakefield Diagnostic Based on Time Domain Rayleigh Refractometry with Holographic Inversion, will be presented.

  8. Applying Quantum Cascade Laser Spectroscopy in Plasma Diagnostics

    Directory of Open Access Journals (Sweden)

    Jürgen Röpcke

    2016-07-01

    Full Text Available The considerably higher power and wider frequency coverage available from quantum cascade lasers (QCLs in comparison to lead salt diode lasers has led to substantial advances when QCLs are used in pure and applied infrared spectroscopy. Furthermore, they can be used in both pulsed and continuous wave (cw operation, opening up new possibilities in quantitative time resolved applications in plasmas both in the laboratory and in industry as shown in this article. However, in order to determine absolute concentrations accurately using pulsed QCLs, careful attention has to be paid to features like power saturation phenomena. Hence, we begin with a discussion of the non-linear effects which must be considered when using short or long pulse mode operation. More recently, cw QCLs have been introduced which have the advantage of higher power, better spectral resolution and lower fluctuations in light intensity compared to pulsed devices. They have proved particularly useful in sensing applications in plasmas when very low concentrations have to be monitored. Finally, the use of cw external cavity QCLs (EC-QCLs for multi species detection is described, using a diagnostics study of a methane/nitrogen plasma as an example. The wide frequency coverage of this type of QCL laser, which is significantly broader than from a distributed feedback QCL (DFB-QCL, is a substantial advantage for multi species detection. Therefore, cw EC-QCLs are state of the art devices and have enormous potential for future plasma diagnostic studies.

  9. Femtosecond Fiber Lasers Based on Dissipative Processes for Nonlinear Microscopy

    Science.gov (United States)

    Wise, Frank W.

    2012-01-01

    Recent progress in the development of femtosecond-pulse fiber lasers with parameters appropriate for nonlinear microscopy is reviewed. Pulse-shaping in lasers with only normal-dispersion components is briefly described, and the performance of the resulting lasers is summarized. Fiber lasers based on the formation of dissipative solitons now offer performance competitive with that of solid-state lasers, but with the benefits of the fiber medium. Lasers based on self-similar pulse evolution in the gain section of a laser also offer a combination of short pulse duration and high pulse energy that will be attractive for applications in nonlinear bioimaging. PMID:23869163

  10. Laser cleaning of ITER's diagnostic mirrors

    Science.gov (United States)

    Skinner, C. H.; Gentile, C. A.; Doerner, R.

    2012-10-01

    Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We report on laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150 - 420 nm thick. A 1.06 μm Nd laser system provided 220 ns pulses at 8 kHz with typical power densities of 1-2 J/cm^2. The laser beam was fiber optically coupled to a scanner suitable for tokamak applications. The efficacy of mirror cleaning was assessed with a new technique that combines microscopic imaging and reflectivity measurements [1]. The method is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber. Excellent restoration of reflectivity for the carbon coated Mo mirrors was observed after laser scanning under vacuum conditions. For the beryllium coated mirrors restoration of reflectivity has so far been incomplete and modeling indicates that a shorter duration laser pulse is needed. No damage of the molybdenum mirror substrates was observed.[4pt][1] C.H. Skinner et al., Rev. Sci. Instrum. at press.

  11. Nonlinear laser dynamics from quantum dots to cryptography

    CERN Document Server

    Lüdge, Kathy

    2012-01-01

    A distinctive discussion of the nonlinear dynamical phenomena of semiconductor lasers. The book combines recent results of quantum dot laser modeling with mathematical details and an analytic understanding of nonlinear phenomena in semiconductor lasers and points out possible applications of lasers in cryptography and chaos control. This interdisciplinary approach makes it a unique and powerful source of knowledge for anyone intending to contribute to this field of research.By presenting both experimental and theoretical results, the distinguished authors consider solitary lase

  12. Charge Diagnostics for Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, K.; Gonsalves, A. J.; Lin, C.; Sokollik, T.; Smith, A.; Rodgers, D.; Donahue, R.; Bryne, W.; Leemans, W. P.

    2010-06-01

    The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1percent per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm2 and 0.4 pC/ps/mm2, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within +/-10 percent.

  13. Laser ultrasonic diagnostics of residual stress.

    Science.gov (United States)

    Karabutov, Alexander; Devichensky, Anton; Ivochkin, Alexander; Lyamshev, Michael; Pelivanov, Ivan; Rohadgi, Upendra; Solomatin, Vladimir; Subudhi, Manomohan

    2008-11-01

    Ultrasonic NDE is one of the most promising methods for non-destructive diagnostics of residual stresses. However the relative change of sound velocity, which is directly proportional to applied stress, is extremely small. An initial stress of 100 MPa produces the result of deltaV/V approximately 10(-4). Therefore measurements must be performed with high precision. The required accuracy can be achieved with laser-exited ultrasonic transients. Radiation from a Nd-YAG laser (pulse duration 7 ns, pulse energy 100 microJ) was absorbed by the surface of the sample. The exited ultrasonic transients resembled the form of laser pulses. A specially designed optoacoustic transducer was used both for the excitation and detecting of the ultrasonic pulses. The wide frequency band of the piezodetector made it possible to achieve the time-of-flight measurements with an accuracy of about 0.5 ns. This technique was used for measuring of plane residual stress in welds and for in-depth testing of subsurface residual stresses in metals. Plane stress distribution for welded metallic plates of different thicknesses (2-8 mm) and the subsurface stress distribution for titanium and nickel alloys were obtained. The results of conventional testing are in good agreement with the laser ultrasonic method.

  14. Coherent fiber supercontinuum laser for nonlinear biomedical imaging

    Science.gov (United States)

    Tu, Haohua; Liu, Yuan; Liu, Xiaomin; Lægsgaard, Jesper; Turchinovich, Dmitry; Boppart, Stephen A.

    2012-12-01

    Nonlinear biomedical imaging has not benefited from the well-known techniques of fiber supercontinuum generation for reasons such as poor coherence (or high noise), insufficient controllability, low spectral power intensity, and inadequate portability. Fortunately, a few techniques involving nonlinear fiber optics and femtosecond fiber laser development have emerged to overcome these critical limitations. These techniques pave the way for conducting point-of-care nonlinear biomedical imaging by a low-maintenance cost-effective coherent fiber supercontinuum laser, which covers a broad emission wavelength of 350-1700 nm. A prototype of this laser has been demonstrated in label-free multimodal nonlinear imaging of cell and tissue samples.

  15. Advanced Laser and RF Plasma Sources and Diagnostics

    Science.gov (United States)

    2007-06-13

    jacks, fibers, collimators, and breadboards $19,832.71 Interferometry Gunn diode and I-Q mixer $6,775.00 RF Components and Automation High...temperature diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters...diagnostics for both our laser window and radiofrequency air plasmas. We have also acquired a tunable 668 nm diode laser, optical filters, splitters

  16. An intelligent online fault diagnostic scheme for nonlinear systems

    Institute of Scientific and Technical Information of China (English)

    Hing Tung MOK; Che Wai CHAN; Zaiyue YANG

    2008-01-01

    An online fault diagnostic scheme for nonlinear systems based on neurofuzzy networks is proposed in this paper.The scheme involves two stages.In the first stage,the nonlinear system is approximated by a neurofuzzy network,which is trained offline from data obtained during the normal operation of the system.In the second stage,residual is generated online from this network and is modelled by another neurofuzzy network trained online.Fuzzy rules are extracted from this network,and are compared with those in the fault database obmined under different faulty operations,from which faults are diagnosed.The performance of the proposed intelligent fault scheme is illustrated using a two.tank water level control system under different faulty conditions.

  17. Optical diagnostics integrated with laser spark delivery system

    Science.gov (United States)

    Yalin, Azer; Willson, Bryan; Defoort, Morgan; Joshi, Sachin; Reynolds, Adam

    2008-09-02

    A spark delivery system for generating a spark using a laser beam is provided, and includes a laser light source and a laser delivery assembly. The laser delivery assembly includes a hollow fiber and a launch assembly comprising launch focusing optics to input the laser beam in the hollow fiber. The laser delivery assembly further includes exit focusing optics that demagnify an exit beam of laser light from the hollow fiber, thereby increasing the intensity of the laser beam and creating a spark. Other embodiments use a fiber laser to generate a spark. Embodiments of the present invention may be used to create a spark in an engine. Yet other embodiments include collecting light from the spark or a flame resulting from the spark and conveying the light for diagnostics. Methods of using the spark delivery systems and diagnostic systems are provided.

  18. Optically-Based Diagnostics for Gas-Phase Laser Development

    Science.gov (United States)

    2010-08-01

    Phase Laser Development Acknowledgement of Support and Disclaimer This material is based upon work supported by Air Force Office of Scientific...00-2010 4. TITLE AND SUBTITLE Optically-Based Diagnostics for Gas-Phase Laser Development 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM...Sciences Inc. Role of Optical Diagnostics in High Energy Gas Laser Development  Chemically rich, energetic, reacting flow with competing phenomena

  19. Nonlinear light propagation in fs laser-written waveguide arrays

    Directory of Open Access Journals (Sweden)

    Szameit A.

    2013-11-01

    Full Text Available We report on recent achievements in the field of nonlinear light propagation in fs laser-written waveguide lattices. Particular emphasis is thereby given on discrete solitons in such systems.

  20. Laser and nonlinear optical materials: SPIE volume 681

    Energy Technology Data Exchange (ETDEWEB)

    De Shazer, L.G.

    1987-01-01

    This book contains papers arranged under the following session headings: Nonlinear optical crystals; Laser host crystals; Electro-optic and magneto-optic materials; and Characterization of optical materials.

  1. Development of laser-based imaging systems for medical diagnostics

    Science.gov (United States)

    Witte, S.; Salumbides, M.; Peterman, E. J. G.; Brakenhoff, R.; van Dongen, G.; Toonen, R.; Mansvelder, H. D.; Groot, M. L.

    We present a laser system with high wavelength flexibility, suitable for nonlinear microscopy and optical coherence tomography, for visualization of disease-related morphological changes in vivo. A single-shot 2D OCT system is demonstrated.

  2. Pulse operation of semiconductor laser with nonlinear optical feedback

    Science.gov (United States)

    Guignard, Celine; Besnard, Pascal; Mihaescu, Adrian; MacDonald, K. F.; Pochon, Sebastien; Zheludev, Nikolay I.

    2004-09-01

    A semiconductor laser coupled to a gallium-made non linear mirror may exhibit pulse regime. In order to better understand this coupled cavity, stationary solutions and dynamics are described following the standard Lang and Kobayashi equations for a semiconductor laser submitted to nonlinear optical feedback. It is shown that the nonlinearity distorts the ellipse on which lied the stationary solutions, with a ``higher'' part corresponding to lower reflectivity and a ``lower'' part to higher reflectivity. Bifurcation diagrams and nonlinear analysis are presented while the conditions for pulsed operation are discussed.

  3. Coherent fiber supercontinuum laser for nonlinear biomedical imaging

    DEFF Research Database (Denmark)

    Tu, Haohua; Liu, Yuan; Liu, Xiaomin;

    2012-01-01

    Nonlinear biomedical imaging has not benefited from the well-known techniques of fiber supercontinuum generation for reasons such as poor coherence (or high noise), insufficient controllability, low spectral power intensity, and inadequate portability. Fortunately, a few techniques involving...... nonlinear fiber optics and femtosecond fiber laser development have emerged to overcome these critical limitations. These techniques pave the way for conducting point-of-care nonlinear biomedical imaging by a low-maintenance cost-effective coherent fiber supercontinuum laser, which covers a broad emission...... wavelength of 350-1700 nm. A prototype of this laser has been demonstrated in label-free multimodal nonlinear imaging of cell and tissue samples.© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  4. Evaluation of annealing and double ion beam irradiation by a laser-induced and laser-detected surface acoustic wave diagnostic system

    Science.gov (United States)

    Kitazawa, Sin-iti; Wakai, Eiichi; Aoto, Kazumi

    2016-10-01

    The effects of annealing and double ion irradiation on nuclear structural materials were investigated using a novel, non-destructive, non-contact diagnostic method. A laser-induced and laser-detected surface acoustic wave (SAW) was adopted as a diagnostic system. The SAWs propagation velocity and the SAWs vibration velocity along the normal direction of the surface were measured to investigate mechanical properties of the substrates. Change of the shear modulus was detected in the annealed substrates. Non-linear effect on amplitude of the excited SAW was observed on the double ion irradiated materials. The potential of the SAW diagnostic system for assessing nuclear structural materials was demonstrated.

  5. Nonlinear dynamics in photonic crystal nanocavity lasers

    DEFF Research Database (Denmark)

    Skovgård, Troels Suhr; Kristensen, Philip Trøst; Frandsen, Lars Hagedorn

    2009-01-01

    We model coupled nanolasers by adding phase-dependent coupling terms to the Purcell-enhanced laser rate equations. Transitions between phase-locking and complex oscillatory behavior are observed at critical coupling strengths in detuned two-laser systems.......We model coupled nanolasers by adding phase-dependent coupling terms to the Purcell-enhanced laser rate equations. Transitions between phase-locking and complex oscillatory behavior are observed at critical coupling strengths in detuned two-laser systems....

  6. A contactless microwave-based diagnostic tool for high repetition rate laser systems

    CERN Document Server

    Braggio, C

    2014-01-01

    We report on a novel electro-optic device for the diagnostics of high repetition rate laser systems. It is composed of a microwave receiver and of a second order nonlinear crystal, whose irradiation with a train of short laser pulses produces a time-dependent polarization in the crystal itself as a consequence of optical rectification. This process gives rise to the emission of microwave radiation that is detected by a receiver and is analyzed to infer the repetition rate and intensity of the pulses. We believe that this new method may overcome some of the limitations of photodetection techniques.

  7. Nonlinear laser-plasma interaction in magnetized liner inertial fusion

    Science.gov (United States)

    Geissel, Matthias; Awe, T. J.; Bliss, D. E.; Campbell, M. E.; Gomez, M. R.; Harding, E.; Harvey-Thompson, A. J.; Hansen, S. B.; Jennings, C.; Kimmel, M. W.; Knapp, P.; Lewis, S. M.; McBride, R. D.; Peterson, K.; Schollmeier, M.; Scoglietti, D. J.; Sefkow, A. B.; Shores, J. E.; Sinars, D. B.; Slutz, S. A.; Smith, I. C.; Speas, C. S.; Vesey, R. A.; Porter, J. L.

    2016-03-01

    Sandia National Laboratories is pursuing a variation of Magneto-Inertial Fusion called Magnetized Liner Inertial Fusion, or MagLIF. The MagLIF approach requires magnetization of the deuterium fuel, which is accomplished by an initial external B-Field and laser-driven pre-heat. While magnetization is crucial to the concept, it is challenging to couple sufficient energy to the fuel, since laser-plasma instabilities exist, and a compromise between laser spot size, laser entrance window thickness, and fuel density must be found. Nonlinear processes in laser plasma interaction, or laser-plasma instabilities (LPI), complicate the deposition of laser energy by enhanced absorption, backscatter, filamentation and beam-spray. Key LPI processes are determined, and mitigation methods are discussed. Results with and without improvement measures are presented.

  8. Laser signals' nonlinear change in fatty acids

    CERN Document Server

    Ghelmez-Dumitru, M; Piscureanu, M; Sterian, A

    2003-01-01

    Previous works showed that thin layers of fatty acids and fatty acid-cholesterol mixtures behaved as optical liquid crystals, even at low incident laser power. The paper presents an experimental and computer study of laser signals, emergent from such samples, in presence of fluctuations. The optical emergent laser beams' features at different incident parameters were experimentally determined for different type (c.w. and pulsed) lasers, as for example helium-neon and Nd sup 3 sup + glass lasers. The results were correlated with the amount of cholesterol in mixtures and with their response in external electric field. These measurements are in all cases affected by fluctuations. We developed some computer-based procedures, by using the TableCurve3D from Jandel Scientific software and equations Runge-Kutta in MATLAB for taking into account these fluctuations.

  9. Nonlinear behaviors of parity-time-symmetric lasers

    CERN Document Server

    Yang, Jianke

    2016-01-01

    We propose a time-dependent partial differential equation model to investigate the dynamical behavior of the parity-time (PT) symmetric laser during the nonlinear stage of its operation. This model incorporates physical effects such as the refractive index distribution, dispersion, material loss, nonlinear gain saturation and self-phase modulation. We show that when the loss is weak, multiple stable steady states and time-periodic states of light exist above the lasing threshold, rendering the laser multi-mode. However, when the loss is strong, only a single stable steady state of broken PT symmetry exists for a wide range of the gain amplitude, rendering the laser single-mode. These results reveal the important role the loss plays in maintaining the single-mode operation of PT lasers.

  10. Nonlinear laser pulse response in a crystalline lens.

    Science.gov (United States)

    Sharma, R P; Gupta, Pradeep Kumar; Singh, Ram Kishor; Strickland, D

    2016-04-01

    The propagation characteristics of a spatial Gaussian laser pulse have been studied inside a gradient-index structured crystalline lens with constant-density plasma generated by the laser-tissue interaction. The propagation of the laser pulse is affected by the nonlinearities introduced by the generated plasma inside the crystalline lens. Owing to the movement of plasma species from a higher- to a lower-temperature region, an increase in the refractive index occurs that causes the focusing of the laser pulse. In this study, extended paraxial approximation has been applied to take into account the evolution of the radial profile of the Gaussian laser pulse. To examine the propagation characteristics, variation of the beam width parameter has been observed as a function of the laser power and initial beam radius. The cavitation bubble formation, which plays an important role in the restoration of the elasticity of the crystalline lens, has been investigated.

  11. Higher order nonlinearity and synchronization of quantum cascade lasers

    Institute of Scientific and Technical Information of China (English)

    Taraprasad Chattopadhyay; Prosenjit Bhattacharyya

    2011-01-01

    This paper presents a closed-form analysis of the synchronization phenomenon of the quantum cascade laser (QCL). The analysis has been made with considering higher order nonlinearity of the modal gain of the QCL. The frequency response characteristics of the synchronized QCL along with the stability of the locked state, the effect of nonlinearity on the lockband of the QCL and the amplitude limiting action of the locked QCL have been calculated. The analysis demonstrates the effect of higher order nonlinearity on the properties of the synchronized QCL.

  12. Nonlinear Interaction of Transversal Modes in a CO2 Laser

    OpenAIRE

    Lopez-Ruiz, Ricardo; Mindlin, G. B.; Perez-Garcia, C.; Tredicce, J. R.

    2002-01-01

    We show the possibility of achieving experimentally a Takens-Bogdanov bifurcation for the nonlinear interaction of two transverse modes ($l = \\pm 1$) in a $CO_2$ laser. The system has a basic O(2) symmetry which is perturbed by some symmetry-breaking effects that still preserve the $Z_2$ symmetry. The pattern dynamics near this codimension two bifurcation under such symmetries is described. This dynamics changes drastically when the laser properties are modified.

  13. Nonlinear mixing of laser generated narrowband Rayleigh surface waves

    Science.gov (United States)

    Bakre, Chaitanya; Rajagopal, Prabhu; Balasubramaniam, Krishnan

    2017-02-01

    This research presents the nonlinear mixing technique of two co-directionally travelling Rayleigh surface waves generated and detected using laser ultrasonics. The optical generation of Rayleigh waves on the specimen is obtained by shadow mask method. In conventional nonlinear measurements, the inherently small higher harmonics are greatly influenced by the nonlinearities caused by coupling variabilities and surface roughness between the transducer and specimen interface. The proposed technique is completely contactless and it should be possible to eliminate this problem. Moreover, the nonlinear mixing phenomenon yields not only the second harmonics, but also the sum and difference frequency components, which can be used to measure the acoustic nonlinearity of the specimen. In this paper, we will be addressing the experimental configurations for this technique. The proposed technique is validated experimentally on Aluminum 7075 alloy specimen.

  14. Optical diagnostics of femtosecond laser plasmas

    Institute of Scientific and Technical Information of China (English)

    LI; Yutong

    2001-01-01

    [1]Benattar, R., Popovics, C., Sigel, R., Polarized light interferometer for laser fusion studies, Rev. Sci. Instrum., 979, 50(2): 583.[2]Young, P. E., Hammer, J. H., Wilks, S. C. et al., Laser beam propagation and channel formation in underdense plasmas, Phys. Plasmas, 995, 2(7): 2825.[3]Zhang, P., He, J.T., Chen, D.B. et al., Effects of a prepulse on γ-ray radiation produced by a femtosecond laser with only mJ energy, Phys. Rev. E., 998, 57: R3746.[4]Stamper, J. A., Review on spontaneous magnetic fields in laser-produced plasmas: phenomena and measurements, Laser and Particle Beams, 99, 9(4): 84.[5]Stamper, J. A., McLean, E. A., Ripin, B. H., Studies of spontaneous magnetic fields in laser-produced plasmas by Faraday rotation, Phys. Rev. Lett., 978, 40(8): 77.[6]Raven, A., Willi, O., Rumsby, P. T., Megagauss magnetic field profiles in laser-produced plasmas, Phys. Rev. Lett., 978, 4(8): 554.[7]Burgess, M. D. J., Luther-Davis, B., Nugent, K. A., An experimental study of magnetic fields in plasmas created by high intensity one micron laser radiation, Phys. Fluids, 985, 28(7): 2286.[8]Borghesi, M., Mackinnon, A. J., Bell, A. R. et al., Megagauss magnetic field generation and plasma jet formation on solid targets irradiated by an ultraintense picosecond laser pulse, Phys. Rev. Lett., 998, 8(): 2.

  15. Laser Excited Fluorescence For Forensic Diagnostics

    Science.gov (United States)

    McKinney, Robert E.

    1986-07-01

    The application of laser excited fluorescence to the detection and identification of latent fingerprints was first accomplished ten years ago. The development of the technology has progressed rapidly with the introduction of commercial equipment by several manufacturers. Systems based on Argon-ion, Copper-vapor, and frequency-doubled Nd:YAG lasers are compared. The theoretical basis of detection by fluorescence is discussed along with the more useful techniques of dye staining. Other applications of the laser excited fluorescence in forensic investigation include gunshot residue analysis, serology, collection of trace evidence, and document examination.

  16. Peak intensity measurement of relativistic lasers via nonlinear Thomson scattering

    CERN Document Server

    Har-Shemesh, Omri

    2011-01-01

    The measurement of peak laser intensities exceeding $10^{20}\\;\\text{W/cm$^2$}$ is in general a very challenging task. We suggest a simple method to accurately measure such high intensities up to about $10^{23}\\,\\text{W/cm$^2$}$, by colliding a beam of ultrarelativistic electrons with the laser pulse. The method exploits the specific features of the angular distribution of the radiation emitted by ultrarelativistic electrons via nonlinear Thomson scattering. Initial electron energies well within the reach of laser wake-field accelerators are required, allowing in principle for an all-optical setup. Accuracies of the order of 10% are envisaged.

  17. Laser-aided diagnostics of plasmas and gases

    CERN Document Server

    Muraoka, K

    2000-01-01

    Updated and expanded from the original Japanese edition, Laser-Aided Diagnostics of Gases and Plasmas takes a unique approach in treating laser-aided diagnostics. The book unifies the subject by joining applications instead of describing each application as a totally separate system. In taking this approach, it highlights the relative strengths of each method and shows how they can complement each other in the study of gases and plasmas.The first part of the book presents a general introduction to the laser-aided study of gases and plasmas, including the various principles and hardware needed for each method, while the second part describes the applications of each general system in detail.Beneficial to a wide spectrum of academic and industrial researchers, this book provides a solid examination of the various options and methods available when involved in the analysis and diagnostics of gases and plasmas.

  18. Laser beam propagation in non-linearly absorbing media

    CSIR Research Space (South Africa)

    Forbes, A

    2006-08-01

    Full Text Available Many analytical techniques exist to explore the propagation of certain laser beams in free space, or in a linearly absorbing medium. When the medium is nonlinearly absorbing the propagation must be described by an iterative process using the well...

  19. A compact microscope setup for multimodal nonlinear imaging in clinics and its application to disease diagnostics.

    Science.gov (United States)

    Meyer, Tobias; Baumgartl, Martin; Gottschall, Thomas; Pascher, Torbjörn; Wuttig, Andreas; Matthäus, Christian; Romeike, Bernd F M; Brehm, Bernhard R; Limpert, Jens; Tünnermann, Andreas; Guntinas-Lichius, Orlando; Dietzek, Benjamin; Schmitt, Michael; Popp, Jürgen

    2013-07-21

    The past years have seen increasing interest in nonlinear optical microscopic imaging approaches for the investigation of diseases due to the method's unique capabilities of deep tissue penetration, 3D sectioning and molecular contrast. Its application in clinical routine diagnostics, however, is hampered by large and costly equipment requiring trained staff and regular maintenance, hence it has not yet matured to a reliable tool for application in clinics. In this contribution implementing a novel compact fiber laser system into a tailored designed laser scanning microscope results in a small footprint easy to use multimodal imaging platform enabling simultaneously highly efficient generation and acquisition of second harmonic generation (SHG), two-photon excited fluorescence (TPEF) as well as coherent anti-Stokes Raman scattering (CARS) signals with optimized CARS contrast for lipid imaging for label-free investigation of tissue samples. The instrument combining a laser source and a microscope features a unique combination of the highest NIR transmission and a fourfold enlarged field of view suited for investigating large tissue specimens. Despite its small size and turnkey operation rendering daily alignment dispensable the system provides the highest flexibility, an imaging speed of 1 megapixel per second and diffraction limited spatial resolution. This is illustrated by imaging samples of squamous cell carcinoma of the head and neck (HNSCC) and an animal model of atherosclerosis allowing for a complete characterization of the tissue composition and morphology, i.e. the tissue's morphochemistry. Highly valuable information for clinical diagnostics, e.g. monitoring the disease progression at the cellular level with molecular specificity, can be retrieved. Future combination with microscopic probes for in vivo imaging or even implementation in endoscopes will allow for in vivo grading of HNSCC and characterization of plaque deposits towards the detection of high

  20. Laser Imaging of Airborne Acoustic Emission by Nonlinear Defects

    Science.gov (United States)

    Solodov, Igor; Döring, Daniel; Busse, Gerd

    2008-06-01

    Strongly nonlinear vibrations of near-surface fractured defects driven by an elastic wave radiate acoustic energy into adjacent air in a wide frequency range. The variations of pressure in the emitted airborne waves change the refractive index of air thus providing an acoustooptic interaction with a collimated laser beam. Such an air-coupled vibrometry (ACV) is proposed for detecting and imaging of acoustic radiation of nonlinear spectral components by cracked defects. The photoelastic relation in air is used to derive induced phase modulation of laser light in the heterodyne interferometer setup. The sensitivity of the scanning ACV to different spatial components of the acoustic radiation is analyzed. The animated airborne emission patterns are visualized for the higher harmonic and frequency mixing fields radiated by planar defects. The results confirm a high localization of the nonlinear acoustic emission around the defects and complicated directivity patterns appreciably different from those observed for fundamental frequencies.

  1. Note: Infrared laser diagnostics for deuterium gas puff Z pinches

    Science.gov (United States)

    Ivanov, V. V.; McKee, E. S.; Hammel, B. D.; Darling, T. W.; Swanson, K. J.; Covington, A. M.

    2017-07-01

    Deuterium gas puff Z pinches have been used for generation of strong neutron fluxes on the MA class pulse power machines. Due to the low electron density of deuterium Z-pinch plasma, regular laser diagnostics in the visible range cannot be used for observation and study of the pinch. Laser probing at the wavelength of 1064 nm was used for visualization of deuterium plasma. Infrared schlieren and interferometry diagnostics showed the deuterium gas puff plasma dynamics, instabilities, and allowed for the reconstruction of the profile of the plasma density.

  2. Applications of laser diagnostics in energy conservation research

    Energy Technology Data Exchange (ETDEWEB)

    Hutchinson, R.A.

    1985-02-01

    During the past decade, intensive research and development has demonstrated the feasibility, checked the accuracy, and extended the sensitivity of laser diagnostics for combustion systems. Combinations of diagnostics can now provide in-situ, time-, and space-resolved measurements of temperature, velocity, and species concentration. Although these tools are powerful, they also can be exceedingly difficult to use, and their application remains largely in the hands of specialized instrument developers rather than problem-oriented researchers. This report outlines a variety of applications for existing diagnostics that may interest both instrument developers and researchers in particular fields.

  3. Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Matlis, N. H.; Bakeman, M.; Geddes, C. G. R.; Gonsalves, T.; Lin, C.; Nakamura, K.; Osterhoff, J.; Plateau, G. R.; Schroeder, C. B.; Shiraishi, S.; Sokollik, T.; van Tilborg, J.; Toth, Cs.; Leemans, W. P.

    2010-06-01

    We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g., diverse forms of electromagnetic emission) and difficulties (e.g., shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

  4. Laser Plasma Physics - Forces and Nonlinear Principle

    CERN Document Server

    Hora, Heinrich

    2014-01-01

    This work is an electronic pre-publication of a book manuscript being under consideration in order to provide information to interested researchers about a review of mechanical forces in plasmas by electro-dynamic fields. Beginning with Kelvin's ponderomotive force of 1845 in electrostatics, the hydrodynamic force in a plasma is linked with quadratic force quantities of electric and magnetic fields. Hydrodynamics is interlinked with single particle motion of plasma particles electric field generation and double layers and sheaths due to properties of inhomogeneous plasmas. Consequences relate to laser driven particle acceleration and fusion energy. Beyond the very broad research field of fusion using nanosecond laser pulses based on thermodynamics, the new picosecond pulses of ultrahigh power opened a categorically different non-thermal interaction finally permitting proton-boron fusion with eliminating problems of nuclear radiation.

  5. Diagnostics hardening for harsh environment in Laser Megajoule (invited).

    Science.gov (United States)

    Bourgade, J L; Marmoret, R; Darbon, S; Rosch, R; Troussel, P; Villette, B; Glebov, V; Shmayda, W T; Gomme, J C; Le Tonqueze, Y; Aubard, F; Baggio, J; Bazzoli, S; Bonneau, F; Boutin, J Y; Caillaud, T; Chollet, C; Combis, P; Disdier, L; Gazave, J; Girard, S; Gontier, D; Jaanimagi, P; Jacquet, H P; Jadaud, J P; Landoas, O; Legendre, J; Leray, J L; Maroni, R; Meyerhofer, D D; Miquel, J L; Marshall, F J; Masclet-Gobin, I; Pien, G; Raimbourg, J; Reverdin, C; Richard, A; Rubin de Cervens, D; Sangster, C T; Seaux, J P; Soullie, G; Stoeckl, C; Thfoin, I; Videau, L; Zuber, C

    2008-10-01

    The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

  6. Diagnostics hardening for harsh environment in Laser Megajoule

    Energy Technology Data Exchange (ETDEWEB)

    Bourgade, J.L.; Marmoret, R.; Darbon, S.; Rosch, R.; Troussel, P.; Villette, B.; Aubard, F.; Baggio, J.; Bazzoli, S.; Bonneau, F.; Boutin, J.Y.; Caillaud, T.; Chollet, C.; Combis, P.; Disdier, L.; Gazave, J.; Girard, S.; Gontier, D.; Jacquet, H.P.; Jadaud, J.P.; Landoas, O.; Legendre, J.; Leray, J.L.; Maroni, R.; Miquel, J.L.; Masclet-Gobin, I.; Raimbourg, J.; Reverdin, C.; Richard, A.; Rubin de Cervens, D.; Soullie, G.; Thfoin, I.; Videau, L.; Zuber, C. [CEA Bruyeres-le-Chatel, 91 (France); Glebov, V.; Shmayda, W.T.; Jaanimagi, P.; Meyerhofer, D.D.; Marshall, F.J.; Pien, G.; Sangster, C.T.; Stoeckl, C. [Rochester Univ., Laser Energetics Lab., Rochester, NY (United States); Gomme, J.C.; Le Tonqueze, Y.; Seaux, J.P. [CESTA - CEA Centre d' Etudes Scientifiques et Techniques d' Aquitaine, 33 - Le Barp (France)

    2008-07-01

    The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection. (authors)

  7. Nonlinear dynamics from lasers to butterflies

    CERN Document Server

    Ball, R

    2003-01-01

    This book is an inspirational introduction to modern research directions and scholarship in nonlinear dynamics, and will also be a valuable reference for researchers in the field. With the scholarly level aimed at the beginning graduate student, the book will have broad appeal to those with an undergraduate background in mathematical or physical sciences.In addition to pedagogical and new material, each chapter reviews the current state of the area and discusses classic and open problems in engaging, surprisingly non-technical ways. The contributors are Brian Davies (bifurcations in maps), Nal

  8. Online plasma diagnostics of a laser-produced plasma

    Science.gov (United States)

    Kai, Gao; Nasr, A. M. Hafz; Song, Li; Mohammad, Mirzaie; Guangyu, Li; Quratul, Ain

    2017-01-01

    In this study, we report a laser interferometry experiment for the online-diagnosing of a laser-produced plasma. The laser pulses generating the plasma are ultra-fast (30 femtoseconds), ultra-intense (tens of Terawatt) and are focused on a helium gas jet to generate relativistic electron beams via the laser wakefield acceleration (LWFA) mechanism. A probe laser beam (λ = 800 nm) which is split-off the main beam is used to cross the plasma at the time of arrival of the main pulse, allowing online plasma density diagnostics. The interferometer setup is based on the NoMarski method in which we used a Fresnel bi-prism where the probe beam interferes with itself after crossing the plasma medium. A high-dynamic range CCD camera is used to record the interference patterns. Based upon the Abel inversion technique, we obtained a 3D density distribution of the plasma density.

  9. Nonlinear absorption of ultrashort laser pulses in thin metal films

    CERN Document Server

    Manfredi, G; Manfredi, Giovanni; Paul-Antoine Hervieux

    2005-01-01

    Self-consistent simulations of the ultrafast electron dynamics in thin metal films are performed. A regime of nonlinear oscillations is observed, which corresponds to ballistic electrons bouncing back and forth against the film surfaces. When an oscillatory laser field is applied to the film, the field energy is partially absorbed by the electron gas. Maximum absorption occurs when the period of the external field matches the period of the nonlinear oscillations, which, for sodium films, lies in the infrared range. Possible experimental implementations are discussed.

  10. Optical diagnostics for laser wakefields in plasma channels

    Science.gov (United States)

    Gaul, E. W.; Le Blanc, S. P.; Downer, M. C.

    1998-11-01

    Laser wakefield accelerators can excite large amplitude electrostatic fields (E >= 100 GV/m) which are potentially suitable for compact accelerators and advanced high energy colliders. An accurate diagnostic tool is necessary to test the physical effects in the wakefield predicted by theory and numerical simulations, and to have control over experiments. Frequency domain interferometry (FDI) (C. W. Siders et. al.), Phys. Rev. Lett. 76, 3570 (1995) has been developed in previous work. We experimentally demonstrate single-shot FDI as a sensitive diagnostic technique for probing laser wakefields. To generate wakefields longer than the diffraction limit, optical guiding of the laser pulse is necessary. An optical guide is formed by the hydrodynamic expansion of a cylindrical shock wave driven by a laser heated plasma, which is generated by laser pulse focused with an axicon lens (C. G. Durfee and H. M. Milchberg, Phys. Rev. Lett. 71, 2409 (1993)) to intensities of ~= 10^13 W/cm^2. These are too low to reach multi-photon ionization or significant collisional ionization in <= 1 atm helium. We preionize Helium gas with an electrical discharge for efficient inverse bremsstrahlung absorption of the laser pulse and formation of a plasma channel. Spatially resolved chirped pulse interferometry is used to measure the radial electron density profile of the channel.

  11. Nonlinear optics with coherent free electron lasers

    Science.gov (United States)

    Bencivenga, F.; Capotondi, F.; Mincigrucci, R.; Cucini, R.; Manfredda, M.; Pedersoli, E.; Principi, E.; Simoncig, A.; Masciovecchio, C.

    2016-12-01

    We interpreted the recent construction of free electron laser (FELs) facilities worldwide as an unprecedented opportunity to bring concepts and methods from the scientific community working with optical lasers into the domain of x-ray science. This motivated our efforts towards the realization of FEL-based wave-mixing applications. In this article we present new extreme ultraviolet transient grating (X-TG) data from vitreous SiO2, collected using two crossed FEL pulses (photon frequency 38 eV) to generate the X-TG and a phase matched optical probing pulse (photon frequency 3.1 eV). This experiment extends our previous investigation, which was carried out on a nominally identical sample using a different FEL photon frequency (45 eV) to excite the X-TG. The present data are featured by a peak intensity of the X-TG signal substantially larger than that previously reported and by slower modulations of the X-TG signal at positive delays. These differences could be ascribed to the different FEL photon energy used in the two experiments or to differences in the sample properties. A systematic X-TG study on the same sample as a function of the FEL wavelength is needed to draw a consistent conclusion. We also discuss how the advances in the performance of the FELs, in terms of generation of fully coherent photon pulses and multi-color FEL emission, may push the development of original experimental strategies to study matter at the femtosecond-nanometer time-length scales, with the unique option of element and chemical state specificity. This would allow the development of advanced experimental tools based on wave-mixing processes, which may have a tremendous impact in the study of a large array of phenomena, ranging from nano-dynamics in complex materials to charge and energy transfer processes.

  12. Linear and Nonlinear Damage Detection Using a Scanning Laser Vibrometer

    Directory of Open Access Journals (Sweden)

    Steve Vanlanduit

    2002-01-01

    Full Text Available Because a Scanning Laser Vibrometer (SLV can perform vibration measurements with a high spatial resolution, it is an ideal instrument to accurately locate damage in a structure. Unfortunately, the use of linear damage detection features, as for instance FRFs or modal parameters, does not always lead to a successful identification of the damage location. Measurement noise and nonlinear distortions can make the damage detection procedure difficult. In this article, a combined linear-nonlinear strategy to detect and locate damage in a structure with the aid of a SLV, will be proposed. To minimize the effect of noise, the modal parameters will be estimated using a Maximum Likelihood Estimator (MLE. Both noise and nonlinear distortion levels are extracted using the residuals of a two-dimensional spline fit. The validation of the technique will be performed on SLV measurements of a delaminated composite plate.

  13. Advanced laser diagnostics for diamond deposition research

    Energy Technology Data Exchange (ETDEWEB)

    Kruger, C.H.; Owano, T.G.; Wahl, E.H. [Stanford Univ., CA (United States)

    1995-12-31

    Chemical Vapor Deposition (CVD) using thermal plasmas is attractive for diamond synthesis applications due to the inherently high reactant densities and throughput, but the associated high gas-phase collision rates in the boundary layer above the substrate produce steep thermal and species gradients which can drive the complex plasma chemistry away from optimal conditions. To understand and control these environments, accurate measurements of temperature and species concentrations within the reacting boundary layer are needed. This is challenging in atmospheric pressure reactors due to the highly luminous environment, steep thermal and species gradients, and small spatial scales. The applicability of degenerate four-wave mixing (DFWM) as a spectroscopic probe of atmospheric pressure reacting plasmas has been investigated. This powerful, nonlinear technique has been applied to the measurement of temperature and radical species concentrations in the boundary layer of a diamond growth substrate immersed in a flowing atmospheric pressure plasma. In-situ measurements of CH and C{sub 2} radicals have been performed to determine spatially resolved profiles of vibrational temperature, rotational temperature, and species concentration. Results of these measurements are compared with the predictions of a detailed numerical simulation.

  14. Diagnostics for advanced laser acceleration experiments

    Energy Technology Data Exchange (ETDEWEB)

    Misuri, Alessio [Univ. of Pisa (Italy)

    2002-01-01

    The first proposal for plasma based accelerators was suggested by 1979 by Tajima and Dawson. Since then there has been a tremendous progress both theoretically and experimentally. The theoretical progress is particularly due to the growing interest in the subject and to the development of more accurate numerical codes for the plasma simulations (especially particle-in-cell codes). The experimental progress follows from the development of multi-terawatt laser systems based on the chirped-pulse amplification technique. These efforts have produced results in several experiments world-wide, with the detection of accelerated electrons of tens of MeV. The peculiarity of these advanced accelerators is their ability to sustain extremely large acceleration gradients. In the conventional radio frequency linear accelerators (RF linacs) the acceleration gradients are limited roughly to 100 MV/m; this is partially due to breakdown which occurs on the walls of the structure. The electrical breakdown is originated by the emission of the electrons from the walls of the cavity. The electrons cause an avalanche breakdown when they reach other metal parts of the RF linacs structure.

  15. Diagnostics for advanced laser acceleration experiments

    Energy Technology Data Exchange (ETDEWEB)

    Misuri, Alessio

    2002-06-01

    The first proposal for plasma based accelerators was suggested by 1979 by Tajima and Dawson. Since then there has been a tremendous progress both theoretically and experimentally. The theoretical progress is particularly due to the growing interest in the subject and to the development of more accurate numerical codes for the plasma simulations (especially particle-in-cell codes). The experimental progress follows from the development of multi-terawatt laser systems based on the chirped-pulse amplification technique. These efforts have produced results in several experiments world-wide, with the detection of accelerated electrons of tens of MeV. The peculiarity of these advanced accelerators is their ability to sustain extremely large acceleration gradients. In the conventional radio frequency linear accelerators (RF linacs) the acceleration gradients are limited roughly to 100 MV/m; this is partially due to breakdown which occurs on the walls of the structure. The electrical breakdown is originated by the emission of the electrons from the walls of the cavity. The electrons cause an avalanche breakdown when they reach other metal parts of the RF linacs structure.

  16. Laser-Accelerated Proton Beams as Diagnostics for Cultural Heritage

    Science.gov (United States)

    Barberio, M.; Veltri, S.; Scisciò, M.; Antici, P.

    2017-01-01

    This paper introduces the first use of laser-generated proton beams as diagnostic for materials of interest in the domain of Cultural Heritage. Using laser-accelerated protons, as generated by interaction of a high-power short-pulse laser with a solid target, we can produce proton-induced X-ray emission spectroscopies (PIXE). By correctly tuning the proton flux on the sample, we are able to perform the PIXE in a single shot without provoking more damage to the sample than conventional methodologies. We verify this by experimentally irradiating materials of interest in the Cultural Heritage with laser-accelerated protons and measuring the PIXE emission. The morphological and chemical analysis of the sample before and after irradiation are compared in order to assess the damage provoked to the artifact. Montecarlo simulations confirm that the temperature in the sample stays safely below the melting point. Compared to conventional diagnostic methodologies, laser-driven PIXE has the advantage of being potentially quicker and more efficient. PMID:28266496

  17. Streak Tubes for Diagnostics of Lasers and Plasmas

    Science.gov (United States)

    Sokolov, A. Yu; Konovalov, P. I.; Nurtdinov, R. I.; Vikulin, M. P.; Pryanishnikov, I. G.; Dolotov, A. S.; Krapiva, P. S.

    2016-09-01

    Designing a facility for laser fusion research requires sufficient advancement in diagnostics techniques for lasers and plasmas, including those involving streak camera imaging. Maximum specifications of streak cameras depend on the parameters of streak tubes. The paper illustrates how these devices function, and which of their parameters are limiting. The paper presents a novel technological platform designed at VNIIA, which was used to develop a new generation of streak tubes. Using these streak tubes in streak cameras, the efficiency of streak camera imaging techniques can be improved by several orders of magnitude, and new techniques can be designed.

  18. Semiconductor lasers vs LEDs in diagnostic and therapeutic medicine

    Science.gov (United States)

    Gryko, Lukasz; Zajac, Andrzej; Szymanska, Justyna; Blaszczak, Urszula; Palkowska, Anna; Kulesza, Ewa

    2016-12-01

    Semiconductor emitters are used in many areas of medicine, allowing for new methods of diagnosis, treatment and effective prevention of many diseases. The article presents selected areas of application of semiconductor sources in UVVIS- NIR range, where in recent years competition in semiconductor lasers and LEDs applications has been observed. Examples of applications of analyzed sources are indicated for LLLT, PDT and optical diagnostics using the procedure of color contrast. Selected results of LLLT research of the authors are presented that were obtained by means of the developed optoelectronic system for objectified irradiation and studies on the impact of low-energy laser and LED on lines of endothelial cells of umbilical vein. Usefulness of the spectrally tunable LED lighting system for diagnostic purposes is also demonstrated, also as an illuminator for surface applications - in procedure of variable color contrast of the illuminated object.

  19. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    Science.gov (United States)

    Bolshov, M. A.; Kuritsyn, Yu. A.; Romanovskii, Yu. V.

    2015-04-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review.

  20. Ion acceleration from intense laser-generated plasma: methods, diagnostics and possible applications

    Directory of Open Access Journals (Sweden)

    Torrisi Lorenzo

    2015-06-01

    Full Text Available Many parameters of non-equilibrium plasma generated by high intensity and fast lasers depend on the pulse intensity and the laser wavelength. In conditions favourable for the target normal sheath acceleration (TNSA regime the ion acceleration from the rear side of the target can be enhanced by increasing the thin foil absorbance through the use of nanoparticles and nanostructures promoting the surface plasmon resonance effect. In conditions favourable for the backward plasma acceleration (BPA regime, when thick targets are used, a special role is played by the laser focal position with respect to the target surface, a proper choice of which may result in induced self-focusing effects and non-linear acceleration enhancement. SiC detectors employed in the time-of-flight (TOF configuration and a Thomson parabola spectrometer permit on-line diagnostics of the ion streams emitted at high kinetic energies. The target composition and geometry, apart from the laser parameters and to the irradiation conditions, allow further control of the plasma characteristics and can be varied by using advanced targets to reach the maximum ion acceleration. Measurements using advanced targets with enhanced the laser absorption effect in thin films are presented. Applications of accelerated ions in the field of ion source, hadrontherapy and nuclear physics are discussed.

  1. Advanced targets, diagnostics and applications of laser-generated plasmas

    Science.gov (United States)

    Torrisi, L.

    2015-04-01

    High-intensity sub-nanosecond-pulsed lasers irradiating thin targets in vacuum permit generation of electrons and ion acceleration and high photon yield emission in non-equilibrium plasmas. At intensities higher than 1015 W/cm2 thin foils can be irradiated in the target-normal sheath acceleration regime driving ion acceleration in the forward direction above 1 MeV per charge state. The distributions of emitted ions in terms of energy, charge state and angular emission are controlled by laser parameters, irradiation conditions, target geometry and composition. Advanced targets can be employed to increase the laser absorption in thin foils and to enhance the energy and the yield of the ion acceleration process. Semiconductor detectors, Thomson parabola spectrometer and streak camera can be employed as online plasma diagnostics to monitor the plasma parameters, shot by shot. Some applications in the field of the multiple ion implantation, hadrontherapy and nuclear physics are reported.

  2. Recent developments in high-resolution optical diagnostics of repetitively pulsed laser-target effects

    Science.gov (United States)

    Hugenschmidt, Manfred; Althaus, Marion

    1995-05-01

    High energy densities, as required both in research and in industry, are achieved by the use of lasers. Extremely highpower densities are obtained in the pulsed mode with short microsecond(s) -, ns-, or even ultrashort ps- to fs- pulses. The interaction of such powerful laser pulses with any type of solid state, liquid or gaseous materials is then causing rapidly developing, nonstationary, optically nonlinear processes. Experimental investigations of these effects are therefore requiring special measuring techniques with high spatial and temporal resolution. Optical and optronical methods have proven to be particularly useful. Methods based on laser diagnostics, including high speed photography, cinematography, speckle techniques, holography, videography, infrared techniques or arbitrary combinations of these, are therefore considered to be important tools in these laser effect studies. The investigations reported in the present paper are referring to carbon dioxide-laser effects in intensity ranges which are useful for many industrial applications, such as for example in the field of material processing. Basic interest is actually in pulsed, plasma sustained laser target interaction phenomena which occur above critical threshold power densities, specific for each type of material. Surface induced, highly ionized absorption waves are then determining the energy transfer from the coherent laser radiation field towards the targets. The experiments at ISL were aimed at investigating plasma parameters and their influence on the energy transfer rates, by fast optical, electrical and optronical techniques, such as mentioned above. The results to be discussed refer to target effects, basically observed on optically transparent materials, subject to high average power pulsed carbon dioxide-laser radiation, with repetition rates of several tens to hundred pps at multi-MW/cm2 to GW/cm2 peak power densities and average power densities in the multi-kW/cm2-range.

  3. Optimization of optical nonlinearities in quantum cascade lasers

    Science.gov (United States)

    Bai, Jing

    Nonlinearities in quantum cascade lasers (QCL's) have wide applications in wavelength tunability and ultra-short pulse generation. In this thesis, optical nonlinearities in InGaAs/AlInAs-based mid-infrared (MIR) QCL's with quadruple resonant levels are investigated. Design optimization for the second-harmonic generation (SHG) of the device is presented. Performance characteristics associated with the third-order nonlinearities are also analyzed. The design optimization for SHG efficiency is obtained utilizing techniques from supersymmetric quantum mechanics (SUSYQM) with both material-dependent effective mass and band nonparabolicity. Current flow and power output of the structure are analyzed by self-consistently solving rate equations for the carriers and photons. Nonunity pumping efficiency from one period of the QCL to the next is taken into account by including all relevant electron-electron (e-e) and longitudinal (LO) phonon scattering mechanisms between the injector/collector and active regions. Two-photon absorption processes are analyzed for the resonant cascading triple levels designed for enhancing SHG. Both sequential and simultaneous two-photon absorption processes are included in the rate-equation model. The current output characteristics for both the original and optimized structures are analyzed and compared. Stronger resonant tunneling in the optimized structure is manifested by enhanced negative differential resistance. Current-dependent linear optical output power is derived based on the steady-state photon populations in the active region. The second-harmonic (SH) power is derived from the Maxwell equations with the phase mismatch included. Due to stronger coupling between lasing levels, the optimized structure has both higher linear and nonlinear output powers. Phase mismatch effects are significant for both structures leading to a substantial reduction of the linear-to-nonlinear conversion efficiency. The optimized structure can be fabricated

  4. Tuning Optical Nonlinearity of Laser-Ablation-Synthesized Silicon Nanoparticles via Doping Concentration

    Directory of Open Access Journals (Sweden)

    Lianwei Chen

    2014-01-01

    Full Text Available Silicon nanoparticles at different doping concentrations are investigated for tuning their optical nonlinear performance. The silicon nanoparticles are synthesized from doped silicon wafers by pulsed laser ablation. Their dispersions in water are studied for both nonlinear absorption and nonlinear refraction properties. It is found that the optical nonlinear performance can be modified by the doping concentration. Nanoparticles at a higher doping concentration exhibit better saturable absorption performance for femtosecond laser pulse, which is ascribed to the free carrier absorption mechanism.

  5. Photonics linear and nonlinear interactions of laser light and matter

    CERN Document Server

    Menzel, R

    2007-01-01

    This book covers the fundamental properties and the description of single photons and light beams, experimentally and theoretically. It explains the essentials of linear interactions and most nonlinear interactions between light and matter in both the transparent and absorbing cases. It also provides a basic understanding of modern quantum optics and lasers, as well as the principles of nonlinear optical spectroscopy. It is self-consistent and enriched by a large number of calculated illustrations, examples, and descriptive tables. Graduate students in physics and electrical engineering, as well as other sciences, will find this book a thorough introduction to the field, while for lecturers and scientists it is a rich source of useful information and a ready-to-hand reference. The new edition has been thoroughly expanded and revised in all sections

  6. PREFACE: Second International Conference on Optical and Laser Diagnostics

    Science.gov (United States)

    Arcoumanis, C.; Grattan, K. T. V.

    2006-08-01

    The area of optical and laser diagnostics continues to expand and develop, and is now an essential part of many fields in engineering. Indeed it is one of the most interdisciplinary of the topics of today's research, impacting upon areas from fundamental physics to IT and encompassing a wide number of specific fields in engineering today. The proceedings of this, the second International Conference on Optical and Laser Diagnostics (ICOLAD 2005), follows upon the very successful first conference held in 2002, and reflects in its content many of the developments in this area since that time. The aim of a Conference which is an international forum for new ideas and developments in this exciting branch of optical engineering continues, building upon the foundation of research in optical diagnostics and optical sensing for a number of industrial and biomedical application areas at the City University, London. The Conference was structured into a number of sessions, held over three days in London, with the contributed talks led by invited papers from many internationally known and respected experts in their field from the UK, mainland Europe, the United States and Japan. The material covered includes such major themes as laser diagnostics, reciprocating engine-related applications and flow velocity measurement, extending to encompass, for example, biomedical and structural monitoring using advanced optical techniques. The papers draw their authority from the reputations of the authors and the groups and companies internationally that they represent and this volume brings together a valuable cross-section of such world-leading research. The local Organizing Committee would like to acknowledge and thank the industrial sponsors of the Conference and the members of the local and the International Steering Committee for their contribution to the success of this Conference. In particular thanks are due to Ms Claire Pantlin and the Institute of Physics for their work to make

  7. Pixel diamond detectors for excimer laser beam diagnostics

    Science.gov (United States)

    Girolami, M.; Allegrini, P.; Conte, G.; Salvatori, S.

    2011-05-01

    Laser beam profiling technology in the UV spectrum of light is evolving with the increase of excimer lasers and lamps applications, that span from lithography for VLSI circuits to eye surgery. The development of a beam-profiler, able to capture the excimer laser single pulse and process the acquired pixel current signals in the time period between each pulse, is mandatory for such applications. 1D and 2D array detectors have been realized on polycrystalline CVD diamond specimens. The fast diamond photoresponse, in the ns time regime, suggests the suitability of such devices for fine tuning feedback of high-power pulsed-laser cavities, whereas solar-blindness guarantees high performance in UV beam diagnostics, also under high intensity background illumination. Offering unique properties in terms of thermal conductivity and visible-light transparency, diamond represents one of the most suitable candidate for the detection of high-power UV laser emission. The relatively high resistivity of diamond in the dark has allowed the fabrication of photoconductive vertical pixel-detectors. A semitransparent light-receiving back-side contact has been used for detector biasing. Each pixel signal has been conditioned by a multi-channel read-out electronics made up of a high-sensitive integrator and a Σ-Δ A/D converter. The 500 μs conversion time has allowed a data acquisition rate up to 2 kSPS (Sample Per Second).

  8. 50 years LASERS: in vitro diagnostics, clinical applications and perspectives.

    Science.gov (United States)

    Spyropoulos, Basile

    2011-01-01

    1960 Theodore Maiman built the first Ruby-LASER, starting-point for half a century of R&D on Biomedical LASER continuous improvement. The purpose of this paper is to contribute a review of the often disregarded, however, extremely important Industrial Property documents of LASER-based in vitro Diagnostics devices. It is an attempt to sketch-out the patent-trail leading towards the modern Biomedical Laboratory and to offer an introduction to the employment of "exotic" systems, such as the Free Electron LASER (FEL), that are expected to focus on the fundamental processes of life, following chemical reactions and biological processes as they happen, on unprecedented time and size scales. There are various in vitro LASER applications, however, the most important ones include: Hybrid Coulter Principle-LASER Hematology Analyzers. Flow Cytometry systems. Fluorescent in situ Hybridization (FISH Techniques). Confocal LASER Scanning Microscopy and Cytometry. From the first fluorescence-based flow Cytometry device developed in 1968 by Wolfgang Göhde until nowadays, numerous improvements and new features related to these devices appeared. The relevant industrial property milestone-documents and their overall numeral trends are presented. In 1971, J. Madey invented and developed the Free Electron LASER (FEL), a vacuum-tube that uses a beam of relativistic electrons passing through a periodic, transverse magnetic field (wiggler) to produce coherent radiation, contained in an optical cavity defined by mirrors. A resonance condition that involves the energy of the electron beam, the strength of the magnetic field, and the periodicity of the magnet determines the wavelength of the radiation. The FEL Coherent Light Sources like the Linac Coherent Light Source (LCLS) at Stanford, CA, USA or the Xray Free Electron LASER (XFEL) at Hamburg, Germany, will work much like a high-speed (LASERS. If the diodes brought a LASER into almost everyone's pocket, the above-mentioned super

  9. Non-Linear Fibres for Widely Tunable Femtosecond Fibre Lasers

    DEFF Research Database (Denmark)

    Pedersen, Martin Erland Vestergaard

    This Ph.D. thesis investigates how intramodal and intermodal nonlinear processes in few-moded fibres can be used to generate light sources at wavelengths outside the spectral gain-bands of rare-earth-doped opticalfibres. The design of two specialty few-moded fibres for use in a widely tunable...... femtosecond fibre laser is presented. The two fibres are used to facilitate the shifting of a soliton in a cascade configuration from the ytterbium gain-band and to a wavelength of 1280 nm. The temporal pulse duration is on a femtosecond scale with a pulse energy of 5 nJ. The experimentally observed soliton...... self-frequency shift and thereby the outcome of the experimental demonstration of the widely tunable femtosecond fibre laser is shown to depend highly on the chirped of the input pulse into the first few-moded fibre in the cascade setup. Furthermore, an alternative splicing process, with a combination...

  10. Nonlinear neutrino-photon interactions inside strong laser pulses

    CERN Document Server

    Meuren, Sebastian; Di Piazza, Antonino

    2015-01-01

    Even though neutrinos are neutral particles and interact only via the exchange of weak gauge bosons, charged leptons and quarks can mediate a coupling to the photon field beyond tree level. Inside a relativistically strong laser field nonlinear effects in the laser amplitude can play an important role, as electrons and positrons interact nonperturbatively with the coherent part of the photon field. Here, we calculate for the first time the leading-order contribution to the axial-vector--vector current-coupling tensor inside an arbitrary plane-wave laser field (which is taken into account exactly by employing the Furry picture). The current-coupling tensor appears in the calculation of various electroweak processes inside strong laser fields like photon emission or trident electron-positron pair production by a neutrino. Moreover, as we will see below, the axial-vector--vector current-coupling tensor contains the Adler-Bell-Jackiw (ABJ) anomaly. This occurrence renders the current-coupling tensor also interest...

  11. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bolshov, M.A., E-mail: bolshov@isan.troitsk.ru; Kuritsyn, Yu.A.; Romanovskii, Yu.V.

    2015-04-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review. - Highlights: • Overview of modern TDL-based sensors for combustion • TDL systems, methods of absorption detection and algorithms of data processing • Prominent examples of TDLAS diagnostics of the combustion facilities • Extension of the TDLAS on the tomographic imaging of combustion processes.

  12. Scintillator diagnostics for the detection of laser accelerated ion beams

    Science.gov (United States)

    Cook, N.; Tresca, O.; Lefferts, R.

    2014-09-01

    Laser plasma interaction with ultraintense pulses present exciting schemes for accelerating ions. One of the advantages conferred by using a gaseous laser and target is the potential for a fast (several Hz) repetition rate. This requires diagnostics which are not only suited for a single shot configuration, but also for repeated use. We consider several scintillators as candidates for an imaging diagnostic for protons accelerated to MeV energies by a CO2 laser focused on a gas jet target. We have measured the response of chromium-doped alumina (chromox) and polyvinyl toluene (PVT) screens to protons in the 2-8 MeV range. We have calibrated the luminescent yield in terms of photons emitted per incident proton for each scintillator. We also discuss how light scattering and material properties affect detector resolution. Furthermore, we consider material damage and the presence of an afterglow under intense exposures. Our analysis reveals a near order of magnitude greater yield from chromox in response to proton beams at > 8 MeV energies, while scattering effects favor PVT-based scintillators at lower energies.

  13. Initial Synthetic Diagnostics of Nonlinear Simulation of CSDX

    Science.gov (United States)

    Vaezi, Payam; Holland, Christopher; Thakur, Saikat; Tynan, George

    2015-11-01

    The Controlled Shear Decorrelation Experiment (CSDX) linear plasma device provides a simple system for nonlinear studies of coupled drift-wave/zonal flow dynamics. We present numerical simulations of a minimal model of 3D collisional drift-wave physics in CSDX which evolves density, vorticity and electron temperature perturbations, implemented in the BOUndary Turbulence (BOUT++) framework. Equilibrium electron density and temperature profiles are taken from experimental measurements. We have verified the model with both linear analytical theory and nonlinear energy balance analysis. Results show that retaining the radial profile variation of plasma parameters has a significant impact on the simulation results. Application of synthetic Langmuir probes to simulation results reveals that the effect of electron temperature fluctuations is significant for validation of model results against measurements of turbulence characteristics (e.g. fluctuation levels, flux, frequency spectra). Both of these effects are found to be needed for model predictions to be comparable to experimental observations. This work is supported by US DoE under DE-FG02-06ER54871.

  14. On-shot laser beam diagnostics for high-power laser facility with phase modulation imaging

    Science.gov (United States)

    Pan, X.; Veetil, S. P.; Liu, C.; Tao, H.; Jiang, Y.; Lin, Q.; Li, X.; Zhu, J.

    2016-05-01

    A coherent-modulation-imaging-based (CMI) algorithm has been employed for on-shot laser beam diagnostics in high-power laser facilities, where high-intensity short-pulsed lasers from terawatt to petawatt are designed to realize inertial confinement fusion (ICF). A single-shot intensity measurement is sufficient for wave-front reconstruction, both for the near-field and far-field at the same time. The iterative reconstruction process is computationally very efficient and was completed in dozens of seconds by the additional use of a GPU device to speed it up. The compact measurement unit—including a CCD and a piece of pre-characterized phase plate—makes it convenient for focal-spot intensity prediction in the target chamber. It can be placed almost anywhere in high-power laser facilities to achieve near-field wave-front diagnostics. The feasibility of the method has been demonstrated by conducting a series of experiments with diagnostic beams and seed pulses with deactivated amplifiers in our high-power laser system.

  15. Nonlinear scattering in hard tissue studied with ultrashort laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, J. [Technische Fachhochschule Berlin, Univ. of Applied Sciences (Germany); Kim, B.M. [Yonsei Univ., Wonjoo, Kangwon-Do (Korea)

    2002-07-01

    The back-scattered spectrum of ultrashort laser pulses (800 nm, 0.2 ps) was studied in human dental and other hard tissues in vitro below the ablation threshold. Frequency doubled radiation (SHG), frequency tripled radiation and two-photon fluorescence were detected. The relative yield for these processes was measured for various pulse energies. The dependence of the SHG signal on probe thickness was determined in forward and back scattering geometry. SHG is sensitive to linear polarization of the incident laser radiation. SHG in human teeth was studied in vitro showing larger signals in dentin than in cementum and enamel. In carious areas no SHG signal could be detected. Possible applications of higher harmonic radiation for diagnostics and microscopy are discussed. (orig.)

  16. Ultrafast laser diagnostics to investigate initiation fundamentals in energetic materials.

    Energy Technology Data Exchange (ETDEWEB)

    Farrow, Darcie; Jilek, Brook Anton; Kohl, Ian Thomas; Kearney, Sean Patrick

    2013-08-01

    We present the results of a two year early career LDRD project, which has focused on the development of ultrafast diagnostics to measure temperature, pressure and chemical change during the shock initiation of energetic materials. We compare two single-shot versions of femtosecond rotational CARS to measure nitrogen temperature: chirped-probe-pulse and ps/fs hybrid CARS thermometry. The applicability of measurements to the combustion of energetic materials will be discussed. We have also demonstrated laser shock and particle velocity measurements in thin film explosives using stretched femtosecond laser pulses. We will discuss preliminary results from Al and PETN thin films. Agreement between our results and previous work will be discussed.

  17. PREFACE: Third International Conference on Optical and Laser Diagnostics

    Science.gov (United States)

    Arcoumanis, C.; Grattan, K. T. V.

    2007-09-01

    The International Conference on Optical and Laser Diagnostics (ICOLAD 2007), held at City University in May 2007, was the third meeting in this well established series, following upon the first in 2002 and the second in 2005. During that time the area of optical and laser diagnostics has continued to develop and to expand with both the changes seen in the technology and the availability of new optical components and laser systems. The field remains one of the most interdisciplinary of the topics of today's research, impacting upon areas from fundamental physics to IT and encompassing a number of different areas in engineering today. These proceedings are a record of current practice in this area from a Conference which remains an international forum for new ideas and developments in this exciting branch of optical engineering. It builds upon the foundation of research in the broad field of optical diagnostics in a number of industrial and biomedical application areas at the City University, London. The Conference was structured into a number of sessions reflecting topical developments in engine research, optical sensing and measurement and biomedical engineering held over three days in London, with the contributed talks led by invited papers from many internationally known and respected experts in their field from mainland Europe, the United States and Japan and the UK. The material covered encompasses such major themes as laser diagnostics, reciprocating engine-related applications and flow velocity measurement, extending to include biomedical and structural monitoring using advanced optical techniques. The papers at this Conference continue to draw their authority from the reputations of the authors and the groups and companies internationally that they represent. This volume brings together a valuable cross-section of world-leading research at the time. The local Organizing Committee would like to acknowledge and thank the industrial sponsors of the Conference

  18. Medical diagnostics by laser-based analysis of exhaled breath

    Science.gov (United States)

    Giubileo, Gianfranco

    2002-08-01

    IMany trace gases can be found in the exhaled breath, some of them giving the possibility of a non invasive diagnosis of related diseases or allowing the monitoring of the disease in the course of its therapy. In the present lecture the principle of medical diagnosis based on the breath analysis will be introduced and the detection of trace gases in exhaled breath by high- resolution molecular spectroscopy in the IR spectral region will be discussed. A number of substrates and the optical systems for their laser detection will be reported. The following laser based experimental systems has been realised in the Molecular Spectroscopy Laboratory in ENEA in Frascati for the analysis of specific substances in the exhaled breath. A tuneable diode laser absorption spectroscopy (TDLAS) appartus for the measurement of 13C/12C isotopic ratio in carbon dioxide, a TDLAS apparatus for the detection of CH4 and a CO2 laser based photoacoustic system to detect trace ethylene at atmospheric pressure. The experimental set-up for each one of the a.m. optical systems will be shown and the related medical applications will be illustrated. The concluding remarks will be focuses on chemical species that are of major interest for medical people today and their diagnostic ability.

  19. Final Report - DOE Center for Laser Imaging and Cancer Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Alfano, Robert R.; Koutcher, Jason A.

    2002-10-31

    This Final Report summarizes the significant progress made by the researchers, students and staff of the Center for Laser Imaging and Cancer Diagnostics (CLICD) from January 1998 through May 2002. During this period, the Center supported several projects. Most projects were proposed initially, some were added subsequently as their relevance and importance to the DOE mission became evident. DOE support has been leveraged to obtain continuing funding for some projects. Leveraged funds come from various sources, including NIH, Army, NSF and the Air Force. The goal of the Center was to develop laser-based instruments for use in the detection and diagnosis of major diseases, with an emphasis on detection and diagnosis of various cancers. Each of the supported projects is a collaborative effort between physicists and laser scientists and the City College of New York and noted physicians, surgeons, pathologists, and biologists located at medical centers in the Metropolitan area. The participating institutions were: City College of New York Institute for Ultrafast Lasers and Spectroscopy, Hackensack University Medical Center, Lawrence Livermore National Laboratory, Memorial Sloan Kettering Cancer Center, and New York Eye and Ear Institute. Each of the projects funded by the Center is grouped into one of four research categories: a) Disease Detection, b) Non-Disease Applications, c) New Diagnostic Tools, and, d) Education, Training, Outreach and Dissemination. The progress achieved by the multidisciplinary teams was reported in 51 publications and 32 presentations at major national conferences. Also, one U.S. patent was obtained and six U.S. patent applications have been filed for innovations resulting from the projects sponsored by the Center.

  20. Non-Linear EMG Parameters for Differential and Early Diagnostics of Parkinson's Disease.

    Science.gov (United States)

    Meigal, Alexander Y; Rissanen, Saara M; Tarvainen, Mika P; Airaksinen, Olavi; Kankaanpää, Markku; Karjalainen, Pasi A

    2013-01-01

    The pre-clinical diagnostics is essential for management of Parkinson's disease (PD). Although PD has been studied intensively in the last decades, the pre-clinical indicators of that motor disorder have yet to be established. Several approaches were proposed but the definitive method is still lacking. Here we report on the non-linear characteristics of surface electromyogram (sEMG) and tremor acceleration as a possible diagnostic tool, and, in prospective, as a predictor for PD. Following this approach we calculated such non-linear parameters of sEMG and accelerometer signal as correlation dimension, entropy, and determinism. We found that the non-linear parameters allowed discriminating some 85% of healthy controls from PD patients. Thus, this approach offers considerable potential for developing sEMG-based method for pre-clinical diagnostics of PD. However, non-linear parameters proved to be more reliable for the shaking form of PD, while diagnostics of the rigid form of PD using EMG remains an open question.

  1. Nonlinear EMG parameters for differential and early diagnostics of Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Alexander eMeigal

    2013-09-01

    Full Text Available The pre-clinical diagnostics is essential for management of Parkinson’s disease (PD. . Although PD has been studied intensively in the last decades, the pre-clinical indicators of that motor disorder have yet to be established. Several approaches were proposed but the definitive method is still lacking. Here we report on the non-linear characteristics of surface electromyogram (sEMG and tremor acceleration as a possible diagnostic tool, and, in prospective, as a predictor for PD. Following this approach we calculated such nonlinear parameters of sEMG and accelerometer signal as correlation dimension, entropy and determinism. We found that the nonlinear parameters allowed discriminating some 85% of healthy controls from PD patients. Thus, this approach offers considerable potential for developing sEMG-based method for pre-clinical diagnostics of PD. However, non-linear parameters proved to be more reliable for the shaking form of PD, while diagnostics of the rigid form of PD using EMG remains an open question.

  2. Instability and dynamics of two nonlinearly coupled laser beams in a plasma

    CERN Document Server

    Shukla, P K; Marklund, M; Stenflo, L; Kourakis, I; Parviainen, M; Dieckmann, M E

    2006-01-01

    We investigate the nonlinear interaction between two laser beams in a plasma in the weakly nonlinear and relativistic regime. The evolution of the laser beams is governed by two nonlinear Schroedinger equations that are coupled with the slow plasma density response. We study the growth rates of the Raman forward and backward scattering instabilities as well of the Brillouin and self-focusing/modulational instabilities. The nonlinear evolution of the instabilities is investigated by means of direct simulations of the time-dependent system of nonlinear equations.

  3. Determining the nonlinear refractive index of fused quartz by femtosecond laser Z-scan technology

    Science.gov (United States)

    Zhang, Lin; Ren, Huan; Ma, Hua; Shi, Zhendong; Yang, Yi; Yuan, Quan; Feng, Xiaoxuan; Ma, Yurong; Chen, Bo

    2016-10-01

    Z-scan technology is an experimental technique for determining the nonlinear refractive index based on the principle of transformation of phase distortion to amplitude distortion when a laser beam propagates through a nonlinear material. For most of the Z-scan system based on the nanosecond or picosecond laser, the accumulation of thermal effects becomes a big problem in nonlinear refractive index measurement especially for the nonlinear materials such as fused quartz and neodymium glass which have a weak nonlinear refractive effect. To overcome this problem, a system for determining the nonlinear refractive index of optical materials based on the femtosecond laser Z-scan technology is presented. Using this system, the nonlinear refractive index of the fused quartz is investigated.

  4. Role of Density Profiles for the Nonlinear Propagation of Intense Laser Beam through Plasma Channel

    OpenAIRE

    Sonu Sen; Meenu Asthana Varshney; Dinesh Varshney

    2014-01-01

    In this work role of density profiles for the nonlinear propagation of intense laser beam through plasma channel is analyzed. By employing the expression for the dielectric function of different density profile plasma, a differential equation for beamwidth parameter is derived under WKB and paraxial approximation. The laser induces modifications of the dielectric function through nonlinearities. It is found that density profiles play vital role in laser-plasma interaction studies. To have num...

  5. FILAMENTATION INSTABILITY OF LASER BEAMS IN NONLOCAL NONLINEAR MEDIA

    Institute of Scientific and Technical Information of China (English)

    文双春; 范滇元

    2001-01-01

    The filamentation instability of laser beams propagating in nonlocal nonlinear media is investigated. It is shown that the filamentation instability can occur in weakly nonlocal self-focusing media for any degree of nonlocality, and in defocusing media for the input light intensity exceeding a threshold related to the degree of nonlocality. A linear stability analysis is used to predict the initial growth rate of the instability. It is found that the nonlocality tends to suppress filamentation instability in self-focusing media and to stimulate filamentation instability in self-defocusing media. Numerical simulations confirm the results of the linear stability analysis and disclose a recurrence phenomenon in nonlocal self-focusing media analogous to the Fermi-Pasta-Ulam problem.

  6. Relative Nonlinear Electrodynamics Interaction of Charged Particles with Strong and Super Strong Laser Fields

    CERN Document Server

    Avetissian, Hamlet

    2006-01-01

    This book covers a large class of fundamental investigations into Relativistic Nonlinear Electrodynamics. It explores the interaction between charged particles and strong laser fields, mainly concentrating on contemporary problems of x-ray lasers, new type small set-up high-energy accelerators of charged particles, as well as electron-positron pair production from super powerful laser fields of relativistic intensities. It will also discuss nonlinear phenomena of threshold nature that eliminate the concurrent inverse processes in the problems of Laser Accelerator and Free Electron Laser, thus creating new opportunities for solving these problems.

  7. Development of two color laser diagnostics for the ITER poloidal polarimeter.

    Science.gov (United States)

    Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S

    2010-10-01

    Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH(3)OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

  8. Resonant laser techniques for combustion and flow diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fritzon, Rolf

    1998-05-01

    This thesis presents results from two areas of research. Firstly, the resonant coherent laser techniques polarization spectroscopy (PS), degenerate four-wave mixing (DFWM) and stimulated emission (SE) have been developed in the general field of combustion diagnostics. Secondly, laser induced fluorescence (LIF) has been developed and applied for the visualization of mixture fractions in turbulent non reacting flows. PS was developed for instantaneous two-dimensional imaging of minor species in flames, the technique being demonstrated on OH and NO. Various aspects of imaging and of detection in general were investigated. Two-photon induced PS was demonstrated for the detection of NH{sub 3}, CO and N{sub 2} molecules. LIF was monitored simultaneously to allow a quantitative comparison between the techniques. Furthermore, PS and DFWM were developed for instantaneous two-dimensional OH temperature imaging. Through a novel experimental approach based on the use of a dual-wavelength dye laser and a diffraction grating the temperature imaging measurements were performed using only one laser and one CCD camera. A comparison between the two techniques was made. SE was through a crossed-beam arrangement developed for spatially resolved detection of flame species. Two-dimensional LIF was developed and applied for measuring mixture fractions in the shear layer between two co-flowing turbulent gaseous jets. The technique was further applied in a study of the mixing of a turbulent water jet impinging orthogonally onto a flat surface. Average concentration fields in the center-plane of the jet was compared with results from large eddy simulations and with data from the literature 221 refs, 48 figs, 5 tabs

  9. Nonlinear quantum electrodynamic and electroweak processes in strong laser fields

    Energy Technology Data Exchange (ETDEWEB)

    Meuren, Sebastian

    2015-06-24

    Various nonlinear electrodynamic and electroweak processes in strong plane-wave laser fields are considered with an emphasis on short-pulse effects. In particular, the momentum distribution of photoproduced electron-positron pairs is calculated numerically and a semiclassical interpretation of its characteristic features is established. By proving the optical theorem, compact double-integral expressions for the total pair-creation probability are obtained and numerically evaluated. The exponential decay of the photon wave function in a plane wave is included by solving the Schwinger-Dyson equations to leading-order in the quasistatic approximation. In this respect, the polarization operator in a plane wave is investigated and its Ward-Takahashi identity verified. A classical analysis indicates that a photoproduced electron-positron pair recollides for certain initial conditions. The contributions of such recollision processes to the polarization operator are identified and calculated both analytically and numerically. Furthermore, the existence of nontrivial electron-spin dynamics induced by quantum fluctuations is verified for ultra-short laser pulses. Finally, the exchange of weak gauge bosons is considered, which is essential for neutrino-photon interactions. In particular, the axial-vector-vector coupling tensor is calculated and the so-called Adler-Bell-Jackiw (ABJ) anomaly investigated.

  10. Low power continuous wave laser induced optical nonlinearities in saffron ( Crocus Sativus L.)

    Science.gov (United States)

    Nasibov, H.; Mamedbeili, I.

    2010-12-01

    We report on the low power CW laser induced nonlinear optical responses of Saffron (stigmata of Crocus Savitus L.) ethanol and methanol extracts. The optical nonlinearities were investigated by performing Z-scan measurements at 470 and 535 nm wavelengths. At both wavelengths the material has a strong nonlinear refraction, mainly of thermal origin. However, only at 470 nm wavelength the material exhibit pronounced saturable nonlinear absorption. Long-term (70 days) stability measurements indicated that the nonlinearities in the Saffron extracts are due to their nonvolatile components. This study shows that there is great potential for Saffron extracts to be used in nonlinear photonic applications.

  11. Multiwavelength Erbium-doped fiber laser employing nonlinear polarization rotation in a symmetric nonlinear optical loop mirror.

    Science.gov (United States)

    Tian, Jiajun; Yao, Yong; Sun, Yunxu; Yu, Xuelian; Chen, Deying

    2009-08-17

    A new multiwavelength Erbium-doped fiber laser is proposed and demonstrated. The intensity-dependent loss induced by nonlinear polarization rotation in a power-symmetric nonlinear optical loop mirror (NOLM) suppresses the mode competition of an Erbium-doped fiber and ensures stable multiwavelength operation at room temperature. The polarization state and its evolution conditions for stable multiwavelength operation in the ring laser cavity are discussed. The number and spectra region of output wavelength can be controlled by adjusting the work states of NOLM. (c) 2009 Optical Society of America

  12. Theoretical Analysis of Dependence of Nonlinear Effects in Mode-Locked Yb:YAG Lasers with a Highly Nonlinear Intra-Cavity Medium

    Directory of Open Access Journals (Sweden)

    Takeshi Yoshida

    2015-11-01

    Full Text Available Nonlinear ultrashort pulse propagation in a mode-locked Yb:YAG laser with a highly nonlinear intra-cavity medium is analyzed using a nonlinear Schrodinger equation. The output spectra are extended by the increased laser intensity, and spectral bandwidths wider than those of the gain medium are achieved. Moreover, pulse widths are shortened by increased laser intensity to considerably less than those of the gain medium. The simulation results qualitatively agree with the experimental results.

  13. Nonlinear Characteristics of an Intense Laser Pulse Propagating in Partially Stripped Plasmas

    Institute of Scientific and Technical Information of China (English)

    HU Qiang-Lin; LIU Shi-Bing; CHEN Tao; JIANG Yi-Jian

    2005-01-01

    The nonlinear optic characteristics of an intense laser pulse propagating in partially stripped plasmas are investigated analytically. The phase and group velocity of the laser pulse propagation as well as the three general expressions governing the nonlinear optic behavior, based on the photon number conservation, are obtained by considering the partially stripped plasma as a nonlinear optic medium. The numerical result shows that the presence of the bound electrons in partially stripped plasma can significantly change the propagating property of the intense laser pulse.

  14. Laser Induced Nonlinear Optical Properties of Zinc Oxide Thin Film Prepared by Sol-Gel Method

    Directory of Open Access Journals (Sweden)

    Vinay Kumari

    2011-01-01

    Full Text Available Optical nonlinearities of spin coated ZnO thin film have been investigated by using single beam Z-Scan technique in the visible region. X- ray diffraction shows that all films are oriented along the c-axis direction of the hexagonal crystal structure. The average optical transmittance of all films is higher than 80 %. The nonlinear optical parameters viz. nonlinear absorption coefficient (β, nonlinear index of refraction (η2, nonlinear susceptibility (χ3, have been estimated using nanosecond laser pulses of second harmonic of Nd:YAG Laser. The value of nonlinear absorption coefficient β is estimated to be greater than the already reported value. The films clearly exhibit a-ve value of nonlinear refraction at 532 nm which is attributed to the two photon absorption and free carrier absorption. The presence of RSA in ZnO thin films inferes that ZnO is a potential material for the development of optical limiter.

  15. Electron beam charge diagnostics for laser plasma accelerators

    Directory of Open Access Journals (Sweden)

    K. Nakamura

    2011-06-01

    Full Text Available A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs. First, a scintillating screen (Lanex was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160  pC/mm^{2} and 0.4  pC/(ps  mm^{2}, respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within ±8%, showing that they all can provide accurate charge measurements for LPAs.

  16. [Clinical value of scanning laser polarimetry in glaucoma diagnostics].

    Science.gov (United States)

    Kremmer, S; Anastassiou, G; Selbach, J M

    2012-02-01

    The term glaucoma is used as a melting pot of many different diseases which have in common that the retinal ganglion cells and their axons are damaged. Untreated, apoptosis can be induced causing ganglion cell death which subsequently leads to typical glaucomatous damage at the optic nerve head, scotomas of the visual fields, and in the worst case scenario to blindness. It is well known that patients with glaucoma can suffer a 20 to 50 % loss of retinal ganglion cells before a defect becomes evident in standard white on white perimetry. To prevent glaucomatous damage, it is important to detect changes of the retinal ganglion cells and their nerve fibre layer as early as possible and to monitor their follow-up as closely as possible in order to find an adequate treatment of glaucoma, and to control its efficiency. In the past few years, scanning laser polarimetry by means of GDx technology (Carl Zeiss Meditec, Dublin, USA) could be established as a new method to measure the retinal nerve fibre layer not only qualitatively but even quantitatively. Presently, the GDx plays an important role in actual glaucoma diagnostics on account of its high resolution, the comfort for both patient and user, and its highly reproducible measurements. Especially in difficult evaluable optic nerve heads (e. g., micro- and macrodiscs), tilted discs, and optic disc anomalies (e. g., optic nerve drusen) modern nerve fibre diagnostics by means of GDx technology is a helpful enrichment in clinical routine.

  17. Electron Beam Charge Diagnostics for Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Smith, Alan; Rodgers, David; Donahue, Rich; Byrne, Warren; Leemans, Wim

    2011-06-27

    A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/(ps mm{sup 2}), respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within {+-}8%, showing that they all can provide accurate charge measurements for LPAs.

  18. Beam Diagnostics for Laser Undulator Based on Compton Backward Scattering

    CERN Document Server

    Kuroda, R

    2005-01-01

    A compact soft X-ray source is required in various research fields such as material and biological science. The laser undulator based on Compton backward scattering has been developed as a compact soft X-ray source for the biological observation at Waseda University. It is performed in a water window region (250eV - 500 eV) using the interaction between 1047 nm Nd:YLF laser (10ps FWHM) and about 5 MeV high quality electron beam (10ps FWHM) generated from rf gun system. The range of X-ray energy in the water window region has K-shell absorption edges of Oxygen, Carbon and Nitrogen, which mainly constitute of living body. Since the absorption coefficient of water is much smaller than the protein's coefficient in this range, a dehydration of the specimens is not necessary. To generate the soft X-ray pulse stably, the electron beam diagnostics have been developed such as the emittance measurement using double slit scan technique, the bunch length measurement using two frequency analysis technique. In this confere...

  19. Numerical Simulations on Nonlinear Dynamics in Lasers as Related High Energy Physics Phenomena

    Directory of Open Access Journals (Sweden)

    Andreea Rodica Sterian

    2013-01-01

    Full Text Available This paper aims to present some results on nonlinear dynamics in active nanostructures as lasers with quantum wells and erbium doped laser systems using mathematical models, methods, and numerical simulations for some related high energy physics phenomena. We discuss nonlinear dynamics of laser with quantum wells and of fiber optics laser and soliton interactions. The results presented have important implications in particle detection and postdetection processing of information as well as in soliton generation and amplification or in the case that these simulations are thought to be useful in the experiments concerning the high energy particles. The soliton behaviour as particle offers the possibility to use solitons for better understanding of real particles in this field. The developed numerical models concerning nonlinear dynamics in nanostructured lasers, erbium doped laser systems, the soliton interactions, and the obtained results are consistent with the existing data in the literature.

  20. Diagnostic accuracy of laser evoked potentials in diabetic neuropathy.

    Science.gov (United States)

    Di Stefano, G; La Cesa, S; Leone, C; Pepe, A; Galosi, E; Fiorelli, M; Valeriani, M; Lacerenza, M; Pergolini, M; Biasiotta, A; Cruccu, G; Truini, A

    2017-03-04

    Although the most widely agreed neurophysiological tool for investigating small fibre damage is laser evoked potential (LEP) recording, no study has documented its diagnostic accuracy. In this clinical, neurophysiological and skin biopsy study we collected age-corrected LEP normative ranges, verified the association of LEPs with pinprick sensory disturbances in the typical diabetic mixed-fibre polyneuropathy and assessed the sensitivity and specificity of LEPs in diabetic small-fibre neuropathy.From 288 LEP recordings from the face, hand and foot in 73 healthy subjects we collected age-corrected normative ranges for LEPs. We then selected 100 patients with mixed-fibre diabetic neuropathy and 25 patients with possible small-fibre diabetic neuropathy. In the 100 patients with mixed-fibre neuropathy we verified how LEP abnormalities were associated with clinically evident pinprick sensory disturbances. In the 25 patients with possible pure small-fibre neuropathy, using the skin biopsy for assessing the intraepidermal nerve fibre density, as a reference standard, we calculated LEP sensitivity and specificity.In healthy participants, age strongly influenced normative ranges for all LEP variables. By applying age-corrected normative ranges for LEPs, we found that LEPs were strongly associated with pinprick sensory disturbances. In relation to the skin biopsy findings, LEPs yielded 78% sensitivity and 81% specificity in the diagnosis of diabetic small-fibre neuropathy.Our study, providing age-corrected normative ranges for the main LEP data and their diagnostic accuracy, helps to make LEPs more reliable as a clinical diagnostic tool, and proposes this technique as a less invasive alternative to skin biopsy for diagnosing diabetic small-fibre neuropathy.

  1. Ultra-sensitive Absorption Diagnostics of Thin Films for High-power Laser Interference Coatings

    Science.gov (United States)

    2015-01-05

    Absorption Diagnostics of Thin Films for High-power Laser Interference Coatings REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public...Absorption Diagnostics of Thin Films for High-power Laser Interference Coatings FA9550-13-1-0201 Jorge J. Rocca (PI) Oscar E. Martinez Carmen S...work consists of the development of a prototype suitable for incorporation into the deposition chamber. Such powerful diagnostics does not

  2. UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry in the diagnostics of alopecia

    Science.gov (United States)

    Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.

    2016-04-01

    Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.

  3. Nonlinear optics and solid-state lasers advanced concepts, tuning-fundamentals and applications

    CERN Document Server

    Yao, Jianquan

    2012-01-01

    This book covers the complete spectrum of nonlinear optics and all solid state lasers.The book integrates theory, calculations and practical design, technology, experimental schemes and applications. With the expansion and further development of Laser technology, the wavelength spectrum of Lasers had to be enlarged, even to be tunable which requires the use of nonlinear optical and Laser tunable technology. It systematically summarizes and integrates the analysis of international achievements within the last 20 years in this field. It will be helpful for university teachers, graduate students as well as engineers.

  4. Nonlinear Propagation of Coupling Optical Pulse under Compton Scattering in Laser Medium

    Institute of Scientific and Technical Information of China (English)

    HAO Dong-shan; ZHANG Xiao-fu

    2006-01-01

    After considering Kerr nonlinear effect,group velocity dispersion of host and gain distribution of active particle in laser amplifying medium,a basic equation describing propagation of the coupling optical pulse under the multi-photon nonlinear Compton scattering in the laser amplifying medium has been deduced. Besides,the profile and power spectrum of a picosecond-level super-Gaussian coupling pulse in the laser amplifying medium have been discussed when its central frequency coincides with the gain peak frequency of the laser amplifying medium.

  5. Highly Nonlinear Luminescence Induced by Gold Nanoparticles on Glass Surfaces with Continuous-Wave Laser Illumination

    CERN Document Server

    Wu, Yong; Toro, Ligia; Stefani, Enrico

    2015-01-01

    We report on highly nonlinear luminescence being observed from individual spherical gold nanoparticles immobilized on a borosilicate glass surface and illuminated by continuous-wave (CW) lasers with relatively low power. The nonlinear luminescence shows optical super-resolution beyond the diffraction limit in three dimensions compared to the scatting of the excitation laser light. The luminescence intensity from most nanoparticles is proportional to the 5th--7th power of the excitation laser power and has wide excitation and emission spectra across the visible wavelength range. Strong nonlinear luminescence is only observed near the glass surface. High optical nonlinearity excited by low CW laser power is related to a long-lived dark state of the gold nanoparticles, where the excitation light is strongly absorbed. This phenomenon has potential biological applications in super-resolution and deep tissue imaging.

  6. Non-Linear Optical Studies of IR Materials with Infrared Femtosecond Laser

    Science.gov (United States)

    2016-12-15

    AFRL-RD-PS- AFRL-RD-PS- TR-2016-0055 TR-2016-0055 NON-LINEAR OPTICAL STUDIES OF IR MATERIALS WITH INFRARED FEMTOSECOND LASER Enam...ANDREAS SCHMITT-SODY, DR-III ERIN PETTYJOHN, DR-III Program Manager Deputy Chief, High Power Electromagnetics Division This...TITLE AND SUBTITLE Non-Linear Optical Studies of IR Materials with Infrared Femtosecond Laser 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9451-14-1

  7. Eye/Sensor Protection against Laser Irradiation Organic Nonlinear Optical Materials

    Science.gov (United States)

    1989-06-12

    Recent developments in organic nonlinear optical materials for application to eye and sensor protection are reviewed. This compendium includes a...noteworthy organic third-order nonlinear optical materials is included as an appendix. Lasers are playing an important and increasing role in modern

  8. Nonlinear Optical Properties of Novel C60 Derivatives under Picosecond Laser Excitation

    Institute of Scientific and Technical Information of China (English)

    MAO Yan-Li; CHENG Yong-Guang; LIU Jun-Hui; LIN Bing-chen; HUO Yan-Ping; ZENG He-Ping

    2007-01-01

    We investigate the third-order nonlinear optical properties of six novel fullerene derivatives under picosecond laser excitation by Z-scan technique.The experimental results reveal that all the derivatives have very large nonlinear absorption coefficient under 532 nm pulses excitation and great third-order nonlinear refraction index under 1064 nm pulses excitation.The molecular second hyperpolarizabilities are obtained from the experimental results.

  9. Optical and laser spectroscopic diagnostics for energy applications

    Science.gov (United States)

    Tripathi, Markandey Mani

    The continuing need for greater energy security and energy independence has motivated researchers to develop new energy technologies for better energy resource management and efficient energy usage. The focus of this dissertation is the development of optical (spectroscopic) sensing methodologies for various fuels, and energy applications. A fiber-optic NIR sensing methodology was developed for predicting water content in bio-oil. The feasibility of using the designed near infrared (NIR) system for estimating water content in bio-oil was tested by applying multivariate analysis to NIR spectral data. The calibration results demonstrated that the spectral information can successfully predict the bio-oil water content (from 16% to 36%). The effect of ultraviolet (UV) light on the chemical stability of bio-oil was studied by employing laser-induced fluorescence (LIF) spectroscopy. To simulate the UV light exposure, a laser in the UV region (325 nm) was employed for bio-oil excitation. The LIF, as a signature of chemical change, was recorded from bio-oil. From this study, it was concluded that phenols present in the bio-oil show chemical instability, when exposed to UV light. A laser-induced breakdown spectroscopy (LIBS)-based optical sensor was designed, developed, and tested for detection of four important trace impurities in rocket fuel (hydrogen). The sensor can simultaneously measure the concentrations of nitrogen, argon, oxygen, and helium in hydrogen from storage tanks and supply lines. The sensor had estimated lower detection limits of 80 ppm for nitrogen, 97 ppm for argon, 10 ppm for oxygen, and 25 ppm for helium. A chemiluminescence-based spectroscopic diagnostics were performed to measure equivalence ratios in methane-air premixed flames. A partial least-squares regression (PLS-R)-based multivariate sensing methodology was investigated. It was found that the equivalence ratios predicted with the PLS-R-based multivariate calibration model matched with the

  10. Challenges in plasma and laser wakefield accelerated beams diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Cianchi, A., E-mail: alessandro.cianchi@roma2.infn.it [University of Rome Tor Vergata and INFN, V. della Ricerca Scientifica 1, 00133 Rome (Italy); Anania, M.P.; Bellaveglia, M.; Castellano, M.; Chiadroni, E.; Ferrario, M.; Gatti, G. [INFN-LNF - Via E. Fermi 40, 00044 Frascati (RM) (Italy); Marchetti, B. [DESY, Platanenallee 6, D-15738 Zeuthen (Germany); Mostacci, A. [University of Rome La Sapienza, P.le Aldo Moro 5, 00185 Rome (Italy); Pompili, R. [INFN-LNF - Via E. Fermi 40, 00044 Frascati (RM) (Italy); Ronsivalle, C. [ENEA C.R. Frascati, Via E. Fermi,45 00044 Frascati (RM) (Italy); Rossi, A.R.; Serafini, L. [INFN-Mi, Via Celoria, 16 20133 Milano (Italy)

    2013-08-21

    The new frontier in the particle beam accelerator is the so called plasma acceleration. Using the strong electric field inside a plasma it is possible to achieve accelerating gradients in the order of magnitude larger with respect to the actual technologies. Different schemes have been proposed and several already tested, producing beams of energy of several GeV. Mainly two approaches are followed: either the beam is directly produced by the interaction of a TW/PW class laser with a gas jet or a preexisting particle beam is accelerated in a plasma channel. In both cases a precise determination of the emerging beam parameters is mandatory for the fine tuning of the devices. The measurement of these parameters, in particular the emittance, is not trivial, mainly due to the large energy spread and to the tight focusing of these beams or to the background noise produced in the plasma channel. We show the problems related to the diagnostic of this kind of beams and the proposed or already realized solutions.

  11. Challenges in plasma and laser wakefield accelerated beams diagnostic

    Science.gov (United States)

    Cianchi, A.; Anania, M. P.; Bellaveglia, M.; Castellano, M.; Chiadroni, E.; Ferrario, M.; Gatti, G.; Marchetti, B.; Mostacci, A.; Pompili, R.; Ronsivalle, C.; Rossi, A. R.; Serafini, L.

    2013-08-01

    The new frontier in the particle beam accelerator is the so called plasma acceleration. Using the strong electric field inside a plasma it is possible to achieve accelerating gradients in the order of magnitude larger with respect to the actual technologies. Different schemes have been proposed and several already tested, producing beams of energy of several GeV. Mainly two approaches are followed: either the beam is directly produced by the interaction of a TW/PW class laser with a gas jet or a preexisting particle beam is accelerated in a plasma channel. In both cases a precise determination of the emerging beam parameters is mandatory for the fine tuning of the devices. The measurement of these parameters, in particular the emittance, is not trivial, mainly due to the large energy spread and to the tight focusing of these beams or to the background noise produced in the plasma channel. We show the problems related to the diagnostic of this kind of beams and the proposed or already realized solutions.

  12. Laser diagnostics of chemical vapour deposition of diamond films

    CERN Document Server

    Wills, J B

    2002-01-01

    Cavity ring down spectroscopy (CRDS) has been used to make diagnostic measurements of chemically activated CH sub 4 / H sub 2 gas mixtures during the chemical vapour deposition (CVD) of thin diamond films. Absolute absorbances, concentrations and temperatures are presented for CH sub 3 , NH and C sub 2 H sub 2 in a hot filament (HF) activated gas mixture and CH, C sub 2 and C sub 2 H sub 2 in a DC arc plasma jet activated mixture. Measurements of the radical species were made using a pulsed dye laser system to generate tuneable visible and UV wavelengths. These species have greatest concentration in the hottest, activated regions of the reactors. Spatial profiling of the number densities of CH sub 3 and NH radicals have been used as stringent tests of predictions of radical absorbance and number densities made by 3-D numerical simulations, with near quantitative agreement. O sub 2 has been shown to reside in the activated region of the Bristol DC arc jet at concentrations (approx 10 sup 1 sup 3 molecules / cm...

  13. National Ignition Facility, subsystem design requirements beam control {ampersand} laser diagnostics SSDR 1.7

    Energy Technology Data Exchange (ETDEWEB)

    Bliss, E.

    1996-11-01

    This Subsystem Design Requirement document is a development specification that establishes the performance, design, development, and test requirements for the Alignment subsystem (WBS 1.7.1), Beam Diagnostics (WBS 1.7.2), and the Wavefront Control subsystem (WBS 1.7. 3) of the NIF Laser System (WBS 1.3). These three subsystems are collectively referred to as the Beam Control & Laser Diagnostics Subsystem. The NIF is a multi-pass, 192-beam, high-power, neodymium-glass laser that meets requirements set forth in the NIF SDR 002 (Laser System). 3 figs., 3 tabs.

  14. CO2 laser collective Thomson scattering diagnostics on the HT-7 tokamak

    Institute of Scientific and Technical Information of China (English)

    李亚东; 李建刚; 毛剑珊

    2004-01-01

    A CW CO2 laser collective Thomson scattering diagnostics was developed to measure plasma density fluctuations on the HT-7 tokamak. The design and construction of CO2 laser scattering apparatus is described. The laser source is a continuous-wave CO2 laser with a cavity length of 1.9 m and a power output of about 10 W at 10.6 μm. The k-resolution of the system is △k ≈ 3.2 cm-1. The preliminary data from the diagnostic is presented.

  15. Semiconductor laser engineering, reliability and diagnostics a practical approach to high power and single mode devices

    CERN Document Server

    Epperlein, Peter W

    2013-01-01

    This reference book provides a fully integrated novel approach to the development of high-power, single-transverse mode, edge-emitting diode lasers by addressing the complementary topics of device engineering, reliability engineering and device diagnostics in the same book, and thus closes the gap in the current book literature. Diode laser fundamentals are discussed, followed by an elaborate discussion of problem-oriented design guidelines and techniques, and by a systematic treatment of the origins of laser degradation and a thorough exploration of the engineering means to enhance the optical strength of the laser. Stability criteria of critical laser characteristics and key laser robustness factors are discussed along with clear design considerations in the context of reliability engineering approaches and models, and typical programs for reliability tests and laser product qualifications. Novel, advanced diagnostic methods are reviewed to discuss, for the first time in detail in book literature, performa...

  16. X-ray diagnostics for laser matter interaction experiments; Diagnostics X pour les experiences d'interaction laser-matiere

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph

    2000-07-01

    Advances in the field of laser-driven inertially confined thermonuclear fusion research since the early 1990's are reviewed. It covers the experimental techniques used to study the interaction of laser radiation with matter and high density plasma. A high performance instrumentation (diagnostics) for observation of X radiation (from a few eV to a few keV) will be required to understand the physical processes involved in the interaction. This paper is a three-part: first part, describes diagnostics metrology realized around different X-ray sources (synchrotron, laser plasma...); a second part, synthesizes theoretical and experimental X-ray optics studies and show the interest for direct applications as X-ray spectroscopy and X-ray imaging around laser-produced plasma; a third part, is a review of high resolution X-ray imaging, performances of these optical system were summarized. (author)

  17. A Laser-Based Diagnostic Suite for Hypersonic Test Facilities Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR effort, Los Gatos Research (LGR) proposes to develop a suite of laser-based diagnostics for the study of reactive and non-reactive hypersonic flows....

  18. A Laser-Based Diagnostic Suite for Hypersonic Test Facilities Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR effort, Los Gatos Research (LGR) proposes to develop a suite of laser-based diagnostics for the study of reactive and non-reactive hypersonic flows....

  19. Nonlinear modification of the laser noise power spectrum induced by a frequency-shifted optical feedback

    CERN Document Server

    Lacot, Eric; Girardeau, Vadim; Hugon, Olivier; Jacquin, Olivier

    2016-01-01

    In this article, we study the non-linear coupling between the stationary (i.e. the beating modulation signal) and transient (i.e. the laser quantum noise) dynamics of a laser subjected to frequency shifted optical feedback. We show how the noise power spectrum and more specifically the relaxation oscillation frequency of the laser are modified under different optical feedback condition. Specifically we study the influence of (i) the amount of light returning to the laser cavity and (ii) the initial detuning between the frequency shift and intrinsic relaxation frequency. The present work shows how the relaxation frequency is related to the strength of the beating signal and the shape of the noise power spectrum gives an image of the Transfer Modulation Function (i.e. of the amplification gain) of the nonlinear-laser dynamics.The theoretical predictions, confirmed by numerical resolutions, are in good agreements with the experimental data.

  20. Nonlinear theory of laser-induced dipolar interactions in arbitrary geometry

    CERN Document Server

    Shahmoon, Ephraim

    2013-01-01

    Polarizable dipoles, such as atoms, molecules or nanoparticles, subject to laser radiation, may attract or repel each other. We derive a general formalism in which such laser-induced dipole-dipole interactions (LIDDI) in any geometry and for any laser strength are described in terms of the resonant dipole-dipole interaction (RDDI) between dipoles dressed by the laser. Our expressions provide a physically clear and technically simple route towards the analysis of LIDDI in a general geometry. This approach can treat both mechanical and internal-state interactions between the dipoles. Our general results reveal LIDDI effects due to nonlinear dipole-laser interactions, unaccounted for by previous treatments of LIDDI. We discuss, via several simple approaches, the origin of these nonlinear effects and their absence in previous works.

  1. Second harmonic generation of Cosh-Gaussian laser beam in collisional plasma with nonlinear absorption

    Science.gov (United States)

    Singh, Navpreet; Gupta, Naveen; Singh, Arvinder

    2016-12-01

    This paper investigates second harmonic generation (SHG) of an intense Cosh-Gaussian (ChG) laser beam propagating through a preformed underdense collisional plasma with nonlinear absorption. Nonuniform heating of plasma electrons takes place due to the nonuniform irradiance of intensity along the wavefront of laser beam. This nonuniform heating of plasma leads to the self-focusing of the laser beam and thus produces strong density gradients in the transverse direction. The density gradients so generated excite an electron plasma wave (EPW) at pump frequency that interacts with the pump beam to produce its second harmonics. To envision the propagation dynamics of the ChG laser beam, moment theory in Wentzel-Kramers-Brillouin (W.K.B) approximation has been invoked. The effects of nonlinear absorption on self-focusing of the laser beam as well as on the conversion efficiency of its second harmonics have been theoretically investigated.

  2. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  3. In situ Diagnostics During Carbon Nanotube Production by Laser Ablation

    Science.gov (United States)

    Arepalli, Sivaram

    1999-01-01

    The preliminary results of spectral analysis of the reaction zone during the carbon nanotube production by laser ablation method indicate synergetic dependence on dual laser setup. The emission spectra recorded from different regions of the laser ablated plume at different delay times from the laser pulses are used to map the temperatures of C2 and C3. These are compared with Laser Induced Fluorescence (LIF) spectra also obtained during production to model the growth mechanism of carbon nanotubes. Experiments conducted to correlate the spectral features with nanotube yields as a function of different production parameters will be discussed.

  4. Laser cleaning of diagnostic mirrors from tokamak-like carbon contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Maffini, A., E-mail: alessandro.maffini@polimi.it [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Uccello, A. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Dellasega, D. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Milan (Italy); Russo, V. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Perissinotto, S. [Center for Nano Science and Technology @ Polimi, Istituto Italiano di Tecnologia, Milan (Italy); Passoni, M. [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Milan (Italy)

    2015-08-15

    This paper presents a laboratory-scale experimental investigation of laser cleaning of diagnostic First Mirrors (FMs). Redeposition of contaminants sputtered from tokamak first wall onto FMs surface could dramatically decrease their reflectivity in an unacceptable way for the functioning of the plasma diagnostic systems. Laser cleaning is a promising solution to tackle this issue. In this work, pulsed laser deposition was exploited to produce rhodium films functional as FMs and to deposit onto them carbon contaminants with tailored features, resembling those found in tokamaks. The same laser system was also used to perform laser cleaning experiments by means of a sample handling procedure that allows to clean some cm{sup 2} in few minutes. The cleaning effectiveness was evaluated in terms of specular reflectivity recovery and mirror surface integrity. The effect of different laser wavelengths (λ = 1064, 266 nm) on the cleaning process is also addressed.

  5. Baseline-free damage visualization using noncontact laser nonlinear ultrasonics and state space geometrical changes

    Science.gov (United States)

    Liu, Peipei; Sohn, Hoon; Park, Byeongjin

    2015-06-01

    Damage often causes a structural system to exhibit severe nonlinear behaviors, and the resulting nonlinear features are often much more sensitive to the damage than their linear counterparts. This study develops a laser nonlinear wave modulation spectroscopy (LNWMS) so that certain types of damage can be detected without any sensor placement. The proposed LNWMS utilizes a pulse laser to generate ultrasonic waves and a laser vibrometer for ultrasonic measurement. Under the broadband excitation of the pulse laser, a nonlinear source generates modulations at various frequency values due to interactions among various input frequency components. State space attractors are reconstructed from the ultrasonic responses measured by LNWMS, and a damage feature called Bhattacharyya distance (BD) is computed from the state space attractors to quantify the degree of damage-induced nonlinearity. By computing the BD values over the entire target surface using laser scanning, damage can be localized and visualized without relying on the baseline data obtained from the pristine condition of a target structure. The proposed technique has been successfully used for visualizing fatigue crack in an aluminum plate and delamination and debonding in a glass fiber reinforced polymer wind turbine blade.

  6. Nonlinear optical properties of laser synthesized Pt nanoparticles: saturable and reverse saturable absorption

    Science.gov (United States)

    Chehrghani, A.; Torkamany, M. J.

    2014-01-01

    In this paper, the spectral and nonlinear optical properties of a colloidal solution of platinum nanoparticles (Pt NPs) in water are presented. The Pt NPs were prepared by laser ablation of a Pt metallic target in distilled water using a 1064 nm high frequency Nd:YAG laser. The intensity-dependent nonlinear optical absorption and nonlinear refraction behaviors of the sample exposed to the 532 nm nanosecond laser pulses were investigated by applying the Z-scan technique. The saturated nonlinear absorption coefficient 5.4 × 10-7 cm W-1 was obtained in a saturation intensity of 1.8 × 107 W cm-2. The saturable absorption response of the Pt NPs was switched to the reverse saturable absorption in the higher laser intensities. The nonlinear refractive index that has a negative value was increased from -3.5 × 10-13 cm2 W-1 up to -15 × 10-13 cm2 W-1 by increasing the laser intensity.

  7. Characterizaticr of Solid State Laser and Nonlinear Optical Materials.

    Science.gov (United States)

    1995-02-02

    materials useful in the different methods for obtaining frequency agility: narrow line emitters with multiple lasing channels and nonlinear optical materials . In...codoped with two or more rare earth ions were studied and computers models developed to explain their spectral dynamics. The nonlinear optical materials investigated

  8. Nonlinear images of scatterers in chirped pulsed laser beams

    Institute of Scientific and Technical Information of China (English)

    Hu Yong-Hua; Wang You-Wen; Wen Shuang-Chun; Fan Dian-Yuan

    2010-01-01

    The bandwidth and the duration of incident pulsed beam are proved to play important roles in modifying the nonlinear image of amplitude-type scatterer.It is found that the initially positive chirp-type bandwidth can suppress the nonlinear image,while the negative one can enhance it,and that both effects are inversely proportional to the incident pulse duration.Numerical simulations further demonstrate that the location of nonlinear image is at the conjugate plane of the scatterer and that,for negatively pre-chirped pulsed beam,the nonlinear image peak intensity can be higher than that in the corresponding monochromatic case under certain conditions.Moreover the effect of group velocity dispersion on nonlinear image is found to be similar to that of chirp-type bandwidth.

  9. Size-dependent nonlinear absorption and refraction of Ag nanoparticles excited by femtosecond lasers

    Institute of Scientific and Technical Information of China (English)

    Fan Guang-Hua; Qu Shi-Liang; Guo Zhong-Yi; Wang Qiang; Li Zhong-Guo

    2012-01-01

    Silver (Ag) nanoparticles with different average sizes are prepared,and the nonlinear absorption and refraction of these nanoparticles are investigated with femtosecond laser pulses at 800 nm.The smallest Ag nanoparticles show insignificant nonlinear absorption,whereas the larger ones show saturable absorption.By considering the previously reported positive nonlinear absorption of 9 nm Ag nanoparticles,the nonlinear absorptions of Ag nanoparticles are found to be size-dependent.All these nonlinear absorptions can be compatibly explained from the viewpoints of electronic transitions,energy bands and electronic structures in the conduction band of Ag nanoparticles.The nonlinear refraction is attributed to the effect of hot electrons arising from the intraband transition in the s-p conduction band of Ag nanoparticles.

  10. Inverse bremsstrahlung absorption with nonlinear effects of high laser intensity and non-Maxwellian distribution.

    Science.gov (United States)

    Weng, Su-Ming; Sheng, Zheng-Ming; Zhang, Jie

    2009-11-01

    Inverse bremsstrahlung (IB) absorption and evolution of the electron distribution function (EDF) in a wide laser intensity range (10;{12}-10;{17} W/cm;{2}) have been studied systematically by a two velocity-dimension Fokker-Planck code. It is found that Langdon's IB operator overestimates the absorption rate at high laser intensity, consequently with an overdistorted non-Maxwellian EDF. According to the small anisotropy of EDF in the oscillation frame, we introduce an IB operator which is similar to Langdon's but without the low laser intensity limit. This operator is appropriate for self-consistently tackling the nonlinear effects of high laser intensity as well as non-Maxwellian EDF. Particularly, our operator is capable of treating IB absorption properly in the indirect and direct-drive inertial confinement fusion schemes with the National Ignition Facility and Laser MegaJoule laser parameters at focused laser intensity beyond 10;{15} W/cm;{2} .

  11. Contamination and Radiation Effects on Nonlinear Crystals for Space Laser Systems

    Science.gov (United States)

    Abdeldayem, Hossain A.; Dowdye, Edward; Jamison, Tracee; Canham, John; Jaeger, Todd

    2005-01-01

    Space Lasers are vital tools for NASA s space missions and military applications. Although, lasers are highly reliable on the ground, several past space laser missions proved to be short-lived and unreliable. In this communication, we are shedding more light on the contamination and radiation issues, which are the most common causes for optical damages and laser failures in space. At first, we will present results based on the study of liquids and subsequently correlate these results to the particulates of the laser system environment. We present a model explaining how the laser beam traps contaminants against the optical surfaces and cause optical damages and the role of gravity in the process. We also report the results of the second harmonic generation efficiency for nonlinear optical crystals irradiated with high-energy beams of protons. In addition, we are proposing to employ the technique of adsorption to minimize the presence of adsorbing molecules present in the laser compartment.

  12. Polarization of a probe laser beam due to nonlinear QED effects

    Science.gov (United States)

    Shakeri, Soroush; Kalantari, Seyed Zafarollah; Xue, She-Sheng

    2017-01-01

    Nonlinear QED interactions induce different polarization properties on a given probe beam. We consider the polarization effects caused by the photon-photon interaction in laser experiments, when a laser beam propagates through a constant magnetic field or collides with another laser beam. We solve the quantum Boltzmann equation within the framework of the Euler-Heisenberg Lagrangian for both time-dependent and constant background field to explore the time evolution of the Stokes parameters Q, U, and V describing polarization. Assuming an initially linearly polarized probe laser beam, we also calculate the induced ellipticity and rotation of the polarization plane.

  13. Scattered light diagnostics of overdense plasma cavity in solid targets irradiated by an ultraintense laser pulse.

    Science.gov (United States)

    Andreev, A A; Zhidkov, A G; Uesaka, M; Kinoshita, K; Platonov, K Yu

    2002-09-01

    The light scattered backward from a target illuminated by ultraintense laser pulses carries important information about the nonlinear laser-plasma interaction. We analyze the usefulness of this information by plasma corona analysis with the help of an analytical model we developed, and particle-in-cell simulation. The spectrum of scattered light is shown to be shifted, to be broadened, and to be modulated, in comparison with the initial laser spectrum, and the spectral shift is an indicator of laser pulse contrast ratio.

  14. Plasma Channel Diagnostic Based on Laser Centroid Oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Gonsalves, Anthony; Nakamura, Kei; Lin, Chen; Osterhoff, Jens; Shiraishi, Satomi; Schroeder, Carl; Geddes, Cameron; Toth, Csaba; Esarey, Eric; Leemans, Wim

    2010-09-09

    A technique has been developed for measuring the properties of discharge-based plasma channels by monitoring the centroid location of a laser beam exiting the channel as a function of input alignment offset between the laser and the channel. The centroid position of low-intensity (<10{sup 14}Wcm{sup -2}) laser pulses focused at the input of a hydrogen-filled capillary discharge waveguide was scanned and the exit positions recorded to determine the channel shape and depth with an accuracy of a few %. In addition, accurate alignment of the laser beam through the plasma channel can be provided by minimizing laser centroid motion at the channel exit as the channel depth is scanned either by scanning the plasma density or the discharge timing. The improvement in alignment accuracy provided by this technique will be crucial for minimizing electron beam pointing errors in laser plasma accelerators.

  15. Homodyne laser interferometer involving minimal quadrature phase error to obtain subnanometer nonlinearity.

    Science.gov (United States)

    Cui, Junning; He, Zhangqiang; Jiu, Yuanwei; Tan, Jiubin; Sun, Tao

    2016-09-01

    The demand for minimal cyclic nonlinearity error in laser interferometry is increasing as a result of advanced scientific research projects. Research shows that the quadrature phase error is the main effect that introduces cyclic nonlinearity error, and polarization-mixing cross talk during beam splitting is the main error source that causes the quadrature phase error. In this paper, a new homodyne quadrature laser interferometer configuration based on nonpolarization beam splitting and balanced interference between two circularly polarized laser beams is proposed. Theoretical modeling indicates that the polarization-mixing cross talk is elaborately avoided through nonpolarizing and Wollaston beam splitting, with a minimum number of quadrature phase error sources involved. Experimental results show that the cyclic nonlinearity error of the interferometer is up to 0.6 nm (peak-to-valley value) without any correction and can be further suppressed to 0.2 nm with a simple gain and offset correction method.

  16. Nonlinear optical properties of laser deposited CuO thin films

    Energy Technology Data Exchange (ETDEWEB)

    Chen Aiping [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Yang Guang, E-mail: gyang@mail.hust.edu.c [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Long Hua; Li Fang; Li Yuhua [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Lu Peixiang, E-mail: lupeixiang@mail.hust.edu.c [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2009-06-01

    In this work we investigate the third-order optical nonlinearities in CuO films by Z-scan method using a femtosecond laser (800 nm, 50 fs, 200 Hz). Single-phase CuO thin films have been obtained using pulsed laser deposition technique. The structure properties, surface image, optical transmittance and reflectance of the films were characterized by X-ray diffraction, Raman spectroscopy, scanning electron microscopy and UV-vis spectroscopy. The Z-scan results show that laser-deposited CuO films exhibit large nonlinear refractive coefficient, n{sub 2} = - 3.96 x 10{sup -17} m{sup 2}/W, and nonlinear absorption coefficient, {beta} = - 1.69 x 10{sup -10} m/W, respectively.

  17. Backreflection diagnostics for ultra-intense laser plasma experiments based on frequency resolved optical gating

    Science.gov (United States)

    Wagner, F.; Hornung, J.; Schmidt, C.; Eckhardt, M.; Roth, M.; Stöhlker, T.; Bagnoud, V.

    2017-02-01

    We report on the development and implementation of a time resolved backscatter diagnostics for high power laser plasma experiments at the petawatt-class laser facility PHELIX. Pulses that are backscattered or reflected from overcritical plasmas are characterized spectrally and temporally resolved using a specially designed second harmonic generation frequency resolved optical gating system. The diagnostics meets the requirements made by typical experiments, i.e., a spectral bandwidth of more than 30 nm with sub-nanometer resolution and a temporal window of 10 ps with 50 fs temporal resolution. The diagnostics is permanently installed at the PHELIX target area and can be used to study effects such as laser-hole boring or relativistic self-phase-modulation which are important features of laser-driven particle acceleration experiments.

  18. Nonlinear Effects in Quantum Dynamics of Atom Laser: Mean-Field Approach

    Institute of Scientific and Technical Information of China (English)

    JING Hui

    2002-01-01

    Quantum dynamics and statistics of an atom laser with nonlinear binary interactions are investigated inthe framework of mean-field approximation. The linearized effective Hamiltonian of the system is accurately solvable.It is shown that, although the input radio frequency field is in an ordinary Glauber coherent state, the output matterwave will periodically exhibit quadrature squeezing effects purely originated from the nonlinear atom-atom collisions.

  19. Comprehensive experimental analysis of nonlinear dynamics in an optically-injected semiconductor laser

    Directory of Open Access Journals (Sweden)

    Kevin Schires

    2011-09-01

    Full Text Available We present the first comprehensive experimental study, to our knowledge, of the routes between nonlinear dynamics induced in a semiconductor laser under external optical injection based on an analysis of time-averaged measurements of the optical and RF spectra and phasors of real-time series of the laser output. The different means of analysis are compared for several types of routes and the benefits of each are discussed in terms of the identification and mapping of the nonlinear dynamics. Finally, the results are presented in a novel audio/video format that describes the evolution of the dynamics with the injection parameters.

  20. Intracavity frequency doubling of CW Ti:Sapphire laser utilising BiBO nonlinear crystal

    DEFF Research Database (Denmark)

    Thorhauge, Morten; Mortensen, Jesper Liltorp; Tidemand-Lichtenberg, Peter

    Utilising BiBO nonlinear crystal frequency doubling a Ti:Sapphire CW laser gave 100 mW at 405 nm and 53 mW at 392 nm. Stability proved excellent without servo control. Broad tunability was shown around 392 nm.......Utilising BiBO nonlinear crystal frequency doubling a Ti:Sapphire CW laser gave 100 mW at 405 nm and 53 mW at 392 nm. Stability proved excellent without servo control. Broad tunability was shown around 392 nm....

  1. Analysis of Semi-conductor Laser Diode with Two-dimension Nonlinearly Tapered Waveguide

    Institute of Scientific and Technical Information of China (English)

    LI Hong; HAUNG Dexiu

    2001-01-01

    A novel semiconductor laser diode with a two-dimension nonlinearly tapered waveguide is proposed and its property is studied by Fourier expanding method. It is shown that coupling loss between the semiconductor laser diode and a single mode fiber is reduced effectively, the reduction role of the nonlinearly tapered waveguide is more apparent than that of a linearly tapered waveguide , the minimum coupling loss is 0.36 dB, and the far field divergence is decreased. The reduction mechanism is discussed.

  2. Spectroscopic diagnostics of plasma during laser processing of aluminium

    Science.gov (United States)

    Lober, R.; Mazumder, J.

    2007-10-01

    The role of the plasma in laser-metal interaction is of considerable interest due to its influence in the energy transfer mechanism in industrial laser materials processing. A 10 kW CO2 laser was used to study its interaction with aluminium under an argon environment. The objective was to determine the absorption and refraction of the laser beam through the plasma during the processing of aluminium. Laser processing of aluminium is becoming an important topic for many industries, including the automobile industry. The spectroscopic relative line to continuum method was used to determine the electron temperature distribution within the plasma by investigating the 4158 Å Ar I line emission and the continuum adjacent to it. The plasmas are induced in 1.0 atm pure Ar environment over a translating Al target, using f/7 and 10 kW CO2 laser. Spectroscopic data indicated that the plasma composition and behaviour were Ar-dominated. Experimental results indicated the plasma core temperature to be 14 000-15 300 K over the incident range of laser powers investigated from 5 to 7 kW. It was found that 7.5-29% of the incident laser power was absorbed by the plasma. Cross-section analysis of the melt pools from the Al samples revealed the absence of any key-hole formation and confirmed that the energy transfer mechanism in the targets was conduction dominated for the reported range of experimental data.

  3. Relativistic warm plasma theory of nonlinear laser-driven electron plasma waves.

    Science.gov (United States)

    Schroeder, C B; Esarey, E

    2010-05-01

    A relativistic, warm fluid model of a nonequilibrium, collisionless plasma is developed and applied to examine nonlinear Langmuir waves excited by relativistically intense, short-pulse lasers. Closure of the covariant fluid theory is obtained via an asymptotic expansion assuming a nonrelativistic plasma temperature. The momentum spread is calculated in the presence of an intense laser field and shown to be intrinsically anisotropic. Coupling between the transverse and longitudinal momentum variances is enabled by the laser field. A generalized dispersion relation is derived for Langmuir waves in a thermal plasma in the presence of an intense laser field. Including thermal fluctuations in three-velocity-space dimensions, the properties of the nonlinear electron plasma wave, such as the plasma temperature evolution and nonlinear wavelength, are examined and the maximum amplitude of the nonlinear oscillation is derived. The presence of a relativistically intense laser pulse is shown to strongly influence the maximum plasma wave amplitude for nonrelativistic phase velocities owing to the coupling between the longitudinal and transverse momentum variances.

  4. Direct optical imaging of graphene in vitro by nonlinear femtosecond laser spectral reshaping.

    Science.gov (United States)

    Li, Baolei; Cheng, Yingwen; Liu, Jie; Yi, Congwen; Brown, April S; Yuan, Hsiangkuo; Vo-Dinh, Tuan; Fischer, Martin C; Warren, Warren S

    2012-11-14

    Nonlinear optical microscopy, based on femtosecond laser spectral reshaping, characterized and imaged graphene samples made from different methods, both on slides and in a biological environment. This technique clearly discriminates between graphene flakes with different numbers of layers and reveals the distinct nonlinear optical properties of reduced graphene oxide as compared to mechanically exfoliated or chemical vapor deposition grown graphene. The nonlinearity makes it applicable to scattering samples (such as tissue) as opposed to previous methods, such as transmission. This was demonstrated by high-resolution imaging of breast cancer cells incubated with graphene flakes.

  5. Nonlinear fibre-optic devices pumped by semiconductor disk lasers

    Energy Technology Data Exchange (ETDEWEB)

    Chamorovskiy, A Yu; Okhotnikov, Oleg G [Optoelectronics Research Center, Tampere University of Technology, Tampere (Finland)

    2012-11-30

    Semiconductor disk lasers offer a unique combination of characteristics that are particularly attractive for pumping Raman lasers and amplifiers. The advantages of disk lasers include a low relative noise intensity (-150 dB Hz{sup -1}), scalable (on the order of several watts) output power, and nearly diffraction-limited beam quality resulting in a high ({approx}70 % - 90 %) coupling efficiency into a single-mode fibre. Using this technology, low-noise fibre Raman amplifiers operating at 1.3 {mu}m in co-propagation configuration are developed. A hybrid Raman-bismuth doped fibre amplifier is proposed to further increase the pump conversion efficiency. The possibility of fabricating mode-locked picosecond fibre lasers operating under both normal and anomalous dispersion is shown experimentally. We demonstrate the operation of 1.38-{mu}m and 1.6-{mu}m passively mode-locked Raman fibre lasers pumped by 1.29-{mu}m and 1.48-{mu}m semiconductor disk lasers and producing 1.97- and 2.7-ps pulses, respectively. Using a picosecond semiconductor disk laser amplified with an ytterbium-erbium fibre amplifier, the supercontinuum generation spanning from 1.35 {mu}m to 2 {mu}m is achieved with an average power of 3.5 W. (invited paper)

  6. Nonlinear resonance phenomena of a doped fibre laser under cavity-loss modulation: Experimental demonstrations

    Indian Academy of Sciences (India)

    A Ghosh; B K Goswami; R Vijaya

    2010-11-01

    Our experiments with an erbium-doped fibre ring laser (CW, single transverse mode and multiaxial mode) with an intracavity LiNbO3 electro-optic modulator (EOM) display the characteristic features of a nonlinear oscillator (e.g., harmonic and period-2 sub-harmonic resonances) when the EOM driver voltage is modulated periodically. Harmonic resonance leads to period-1 bistability and hysteresis. Inside the period-2 sub-harmonic resonance region, the laser exhibits Feigenbaum sequence and generalized bistability.

  7. Polarization effects and nonlinear switching in fiber figure-eight lasers.

    Science.gov (United States)

    Stentz, A J; Boyd, R W

    1994-09-15

    We have developed a novel experimental procedure that allows us to quantify how polarization effects determine the passive mode locking of an optical fiber figure-eight laser. Based on our measurements, we have performed numerical simulations demonstrating that the nonlinear switching within this laser operates in a manner contrary to that described by the conventional theory of passive mode locking with a fast saturable absorber.

  8. EAST-AIA deployment under vacuum: Calibration of laser diagnostic system using computer vision

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang, E-mail: yangyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Song, Yuntao; Cheng, Yong; Feng, Hansheng; Wu, Zhenwei; Li, Yingying; Sun, Yongjun; Zheng, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Bruno, Vincent; Eric, Villedieu [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France)

    2016-11-15

    Highlights: • The first deployment of the EAST articulated inspection arm robot under vacuum is presented. • A computer vision based approach to measure the laser spot displacement is proposed. • An experiment on the real EAST tokamak is performed to validate the proposed measure approach, and the results shows that the measurement accuracy satisfies the requirement. - Abstract: For the operation of EAST tokamak, it is crucial to ensure that all the diagnostic systems are in the good condition in order to reflect the plasma status properly. However, most of the diagnostic systems are mounted inside the tokamak vacuum vessel, which makes them extremely difficult to maintain under high vacuum condition during the tokamak operation. Thanks to a system called EAST articulated inspection arm robot (EAST-AIA), the examination of these in-vessel diagnostic systems can be performed by an embedded camera carried by the robot. In this paper, a computer vision algorithm has been developed to calibrate a laser diagnostic system with the help of a monocular camera at the robot end. In order to estimate the displacement of the laser diagnostic system with respect to the vacuum vessel, several visual markers were attached to the inner wall. This experiment was conducted both on the EAST vacuum vessel mock-up and the real EAST tokamak under vacuum condition. As a result, the accuracy of the displacement measurement was within 3 mm under the current camera resolution, which satisfied the laser diagnostic system calibration.

  9. Study of nonlinear refraction of organic dye by Z-scan technique using He-Ne laser

    Science.gov (United States)

    Medhekar, S.; Kumar, R.; Mukherjee, S.; Choubey, R. K.

    2013-02-01

    Laser induced third-order nonlinear optical responses of Brilliant Green solution has been investigated by utilizing single beam Z-scan technique with a continuous-wave He-Ne laser radiation at 632.8 nm. It was observed that the material exhibits self-defocusing type optical nonlinearity. The measurements of nonlinear refraction were carried out at different dye concentrations and found that the increase in solution concentration leads to the linear increase of the nonlinear refractive index. The experimental results confirm great potential of the Brilliant Green for the application in nonlinear optical devices.

  10. Study of nonlinear refraction of organic dye by Z-scan technique using He-Ne laser

    Energy Technology Data Exchange (ETDEWEB)

    Medhekar, S.; Kumar, R.; Mukherjee, S.; Choubey, R. K. [Dept. of Applied Physics, Birla Institute of Technology, Mesra, Ranchi - 835215, Jharkhand (India)

    2013-02-05

    Laser induced third-order nonlinear optical responses of Brilliant Green solution has been investigated by utilizing single beam Z-scan technique with a continuous-wave He-Ne laser radiation at 632.8 nm. It was observed that the material exhibits self-defocusing type optical nonlinearity. The measurements of nonlinear refraction were carried out at different dye concentrations and found that the increase in solution concentration leads to the linear increase of the nonlinear refractive index. The experimental results confirm great potential of the Brilliant Green for the application in nonlinear optical devices.

  11. In Situ Laser Diagnostics for Arc-Jet Facilities Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR Phase I effort, Los Gatos Research (LGR) proposes to develop novel instrumentation based on laser absorption spectroscopy techniques for ultrasensitive...

  12. Lasers in diagnostics and treatment of microcirculation disorders under parodontitis

    Science.gov (United States)

    Kozlov, Valentine I.; Krechina, Elena; Terman, Oleg A.

    1995-04-01

    To study microvascular changes in parodontium under the Low Level Laser Therapy the investigation of volunteers and patients with parodontitis has been conducted. With the contact luminescent microscope we have observed the microcirculatory bed under various stages of parodontitis. We have also used the Laser Doppler Flowmeter in assessment of capillary blood flow. Our work has shown that the microcirculation state is dependent on the stage of disease. Tissue blood flow rapidly falls under hard parodontitis stages. The laser therapy in combination with traditional treatment is very effective in the case of the light and middle stages of parodontitis. There are the restoration and even the enhancement of capillary blood flow and the reconstruction of native microvascular bed in parodontium after complex therapy. The long-term results of laser therapy are also positive.

  13. Nonlinear interaction of charged particles with strong laser pulses in a magnetic undulator

    Directory of Open Access Journals (Sweden)

    H. K. Avetissian

    2010-08-01

    Full Text Available Laser acceleration due to the nonlinear-threshold phenomena of charged particle “reflection” and capture by slowed wave in a magnetic undulator is considered. The obtained numerical results prove the particle reflection and capture phenomena in the field of actual laser pulses with temporal and space profiles which lead to the particles acceleration. In contrast to the reflection regime where particle acceleration takes place already at the constant undulator step, in the capture regime it is necessary to increase adiabatically the undulator step along the laser pulse propagation direction by the certain self-consistent variation law corresponding to acceleration rate.

  14. Nonlinear effects in propagation of radiation of X-ray free-electron lasers

    Science.gov (United States)

    Nosik, V. L.

    2016-05-01

    Nonlinear effects accompanying the propagation of high-intensity beams of X-ray free-electron lasers are considered. It is shown that the X-ray wave field in the crystal significantly changes due to the formation of "hollow" atomic shells as a result of the photoelectric effect.

  15. Spectroscopy of laser-induced autoionizing nonlinear resonances in atomic systems

    Science.gov (United States)

    Pavlov, L. I.; Kovachev, V. V.

    2015-03-01

    Efficient harmonic generation at laser-induced autoionizing state in continuum, were observed for the first time by our laboratory [1,2,3]. In this paper, nonlinear frequency mixing in alkali metal vapors at induced continuum structure in Na, are studied in detail. Besides, measurement of nonlinear optical susceptibility at induced autoionizing resonance, is performed. Tunable ultraviolet radiations by four-photon processes near induced resonances are obtained. Estimations of the real and imaginary parts of the nonlinearities, are estimated. We will specially note, that the resonant photoabsorption of ions is experimentally investigated since it gives information about the autoionizing states, which is impossible to obtain on the base only of the emission spectra. We use also laser inducing for obtaining of powerful radiation source in VUV. Thus, many actual problems as the selective impact on matter, laser photochemistry and laser isotope separation are connected directly with the induced autoionizing nonlinear resonances. The main interest is to control the spectral characteristics of continuum. The discrete level from the continuum structure leads to appearance of asymmetrical autoionizing resonance onto the background of the broad-band absorption line.

  16. Glasses having a low non-linear refractive index for laser applications

    Energy Technology Data Exchange (ETDEWEB)

    Faulstich, Marga (Mainz, DE); Jahn, Walter (Ingelheim, DE); Krolla, Georg (Mainz, DE); Neuroth, Norbert (Mainz-Mombach, DE)

    1980-01-01

    Glass composition ranges are described which permit the introduction of laser activators into fluorphosphate glass with exceptionally high fluorine content while forming glasses of high crystallization stability and permitting the realization of large melt volumes. The high fluorine content imparts to the glasses an exceptionally low nonlinear refractive index n.sub.2 down to O,4 .times.10.sup.-13 esu.

  17. Investigation of relativistic laser-plasmas using nuclear diagnostics; Untersuchung relativistischer Laserplasmen mittels nukleardiagnostischer Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc M.

    2011-01-19

    The present work explores with the development of a novel nuclear diagnostic method for the investigation of the electron dynamics in relativistic laser-plasma interactions. An additional aim of this work was the determination of the real laser peak intensity via the interaction of an intense laser short-pulse with a solid target. The nuclear diagnostics is based on a photo-neutron disintegration nuclear activation method. The main constituent of the nuclear diagnostic are novel pseudoalloic activation targets as a kind of calorimeter to measure the high-energy bremsstrahlung produced by relativistic electrons. The targets are composed of several stable isotopes with different ({gamma},xn)-reaction thresholds. The activated nuclides were identified via the characteristic gamma-ray decay spectrum by using high-resolution gamma spectroscopy after the laser irradiation. Via the gamma spectroscopy the ({gamma},xn)-reaction yields were determined. The high-energy bremsstrahlung spectrum has been deconvolved using a novel analysis method based on a modified Penfold-Leiss method. This facilitates the reconstruction of the spectrum of bremsstrahlung photons without any anticipated fit procedures. Furthermore, the characterization of the corresponding bremsstrahlung electrons in the interaction zone is accessible immediately. The consolidated findings about the properties of the relativistic electrons were used to determine the real peak intensity at the laser-plasma interaction zone. In the context of this work, experiments were performed at three different laser facilities. First Experiments were carried out at the 100 TW laser facility at Laboratoire pour l'Utilisation des Lasers Intense (LULI) in France and supplementary at the Vulcan laser facility at Rutherford Appleton Laboratory (RAL) in United Kingdom. The main part of the activation experiments were performed at the PHELIX laser facility (Petawatt High Energy Laser for heavy Ion EXperiments) at GSI

  18. Role of Density Profiles for the Nonlinear Propagation of Intense Laser Beam through Plasma Channel

    Directory of Open Access Journals (Sweden)

    Sonu Sen

    2014-01-01

    Full Text Available In this work role of density profiles for the nonlinear propagation of intense laser beam through plasma channel is analyzed. By employing the expression for the dielectric function of different density profile plasma, a differential equation for beamwidth parameter is derived under WKB and paraxial approximation. The laser induces modifications of the dielectric function through nonlinearities. It is found that density profiles play vital role in laser-plasma interaction studies. To have numerical appreciation of the results the propagation equation for plasma is solved using the fourth order Runge-Kutta method for the initial plane wave front of the beam, using boundary conditions. The spot size of the laser beam decreases as the beam penetrates into the plasma and significantly adds self-focusing in plasma. This causes the laser beam to become more focused by reduction of diffraction effect, which is an important phenomenon in inertial confinement fusion and also for the understanding of self-focusing of laser pulses. Numerical computations are presented and discussed in the form of graphs for typical parameters of laser-plasma interaction.

  19. Extreme events induced by self-action of laser beams in dynamic nonlinear liquid crystal cells

    Science.gov (United States)

    Bugaychuk, S.; Iljin, A.; Chunikhina, K.

    2017-06-01

    Optical extreme events represent a feature of nonlinear systems where there may emerge individual pulses possessing very high (or very low) intensity hardly probable statistically. Such property is being connected with the generation of solitons in the nonlinear systems. We carry out the first experiments for detection of extreme events during two-wave mixing with nonlinear dynamical liquid crystal (LC) cells. We investigate the statistics of the extreme events in dependence on relation between the duration of a laser pulse and the time characteristic of dynamic grating relaxation in LC cell. Our research shows that the self-diffraction of laser beams with a dynamical grating support the generation of envelope solitons in this system.

  20. Generalized Two-State Theory for an Atom Laser with Nonlinear Couplings

    Institute of Scientific and Technical Information of China (English)

    JING Hui; TIAN Li-Jun

    2002-01-01

    We present a generalized two-state theory to investigate the quantum dynamics and statistics of an atom laser with nonlinear couplings. The rotating wave approximate Hamiltonian of the system is proved to be analytically solvable. The fraction of output atoms is then showed to exhibit an interesting collapse and revival phenomenon with respect to the evolution time, a sign of nonlinear couplings. Several nonclassical effects, such as sub-Poissonian distribution, quadrature squeezing effects, second-order cross-correlation and accompanied violation of Cauchy-Schwartz inequality are also revealed for the output matter wave. The initial global phase of the trapped condensate, in weak nonlinear coupling limits, is found to exert an interesting impact on the quantum statistical properties of the propagating atom laser beam.

  1. Laser diagnostics in combustion. Elastic scattering and picosecond laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Ossler, Frederik

    1999-05-01

    .01 and 10 bar. The effective lifetimes generally decrease with temperature and increase with pressure and in different ways for the two substances which gives implications of their use to combustion related studies. The fluorescence emission from gas phase aromatic hydrocarbons has been studied at elevated temperatures and at atmospheric pressure for different concentrations of oxygen (0-10%). Picosecond laser radiation at 266 nm was used for the excitation. The lifetimes for most of the substances decreased between one and two orders of magnitude when the temperature was increased between 400 and 1200 K. The dependence of the lifetimes on temperature and oxygen concentration indicate that the relaxation dynamics is determined by sequences and the density of vibrational states. The results give also some implications to combustion related diagnostics 170 refs, 30 figs, 2 tabs

  2. Laser diagnostics in combustion: Elastic scattering and picosecond laser-induced fluorescence

    Science.gov (United States)

    Ossler, Frederik E.

    bar. The effective lifetimes generally decrease with temperature and increase with pressure and in different ways for the two substances which gives implications of their use to combustion related studies. The fluorescence emission from gas phase aromatic hydrocarbons has been studied at elevated temperatures and at atmospheric pressure for different concentrations of oxygen (0-10%). Picosecond laser radiation at 266 nm was used for the excitation. The lifetimes for most of the substances decreased between one and two orders of magnitude when the temperature was increased between 400 and 1200 K. The dependence of the lifetimes on temperature and oxygen concentration indicate that the relaxation dynamics is determined by sequences and the density of vibrational states. The results give also some implications to combustion related diagnostics.

  3. Simulation of nanosecond square pulse fiber laser based on nonlinear amplifying loop mirror

    Institute of Scientific and Technical Information of China (English)

    Guoliang Chen; Chun Gu; Lixin Xu; Huan Zheng; Hai Ming

    2011-01-01

    A nanosecond square pulse fiber laser based on the nonlinear amplifying loop mirror (NALM) is numerically analyzed by the nonlinear Schrodinger equation. The fiber cavity with a NALM has a tendency to provide pulse shaping effect with nonlinearity increasing in the NALM, and the nanosecond square pulse is generated by the pulse shaping effect. The numerical results show that the stable square pulse can be obtained when the parameters of the NALM are chosen appropriately. The generated square pulses have flat top and no internal structure.%@@ A nanosecond square pulse fiber laser based on the nonlinear amplifying loop mirror(NALM)is numerically analyzed by the nonlinear Schr6dinger equation.The fiber cavity with a NALM has a tendency to provide pulse shaping effect with nonlinearity increasing in the NALM,and the nanosecond square pulse is generated by the pulse shaping effect.The numerical results show that the stable square pulse can be obtained when the parameters of the NALM are chosen appropriately.The generated square pulses have flat top and no internal structure.

  4. A Study of Laser System Requirements for Application in Beam Diagnostics And Polarimetry at the ILC

    Energy Technology Data Exchange (ETDEWEB)

    Dixit, S.; Delerue, N.; Foster, B.; Howell, D.F.; Peach, K.; Quelch, G.; Qureshi, M.; Reichold, A.; /Oxford U.; Hirst, G.; Ross, I.; /Rutherford; Urakawa, J.; /KEK,; Soskov, V.; Variola, A.; Zomer, F.; /Orsay, LAL; Blair, G.A.; Boogert, S.T.; Boorman, G.; Bosco, A.; Driouichi, C.; Karataev, P.; /Royal Holloway, U. of London; Brachmann,; /SLAC

    2007-02-12

    Advanced laser systems will be essential for a range of diagnostics devices and polarimetry at the ILC. High average power, high beam quality, excellent stability and reliability will be crucial in order to deliver the information required to attain the necessary ILC luminosity as well as for efficient polarimetry. The key parameters are listed together with the R & D required to achieve the necessary laser system performance.

  5. Plasma Diagnostic in laser ablation plumes for isotope separation applications

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Juliana B. de [Instituto Tecnologico de Aeronautica, Sao Jose dos Campos, SP (Brazil)]. E-mail: juliana@ieav.cta.br; Rodrigues, Nicolau A.S.; Neri, Jose W.; Silveira, Carlos A.B. [Instituto de Estudos Avancados (IEAv/EFO), Sao Jose dos Campos, SP (Brazil). Div. de Fotonica

    2008-07-01

    The plasma plume produced in vacuum by ablation of copper, aluminum and tungsten samples, illuminated by copper laser pulses, was investigated. A Langmuir probe was used to study the macroscopic parameters electron number density (Ne) and electron temperature (Te). Plasma expansion velocity (Vp) was also investigated and it was studied the dependence of these parameters with the laser irradiance. Typical values are respectively N{sub e} {approx} 10{sup 8}-10{sup 9}/cm{sup 3}, T{sub e} {approx} 15 eV and Vp {approx} 10 km/s. (author)

  6. Nonlinear Optical Properties and Femtosecond Laser Micromachining of Special Glasses

    OpenAIRE

    Almeida,Juliana M. P.; Gustavo F. B. Almeida; Boni, Leonardo De; Cleber R. Mendonça

    2015-01-01

    Materials specially designed for photonics have been at the vanguard of chemistry, physics and materials science, driven by the development of new technologies. One particular class of materials investigated in this context are glasses, that in principle should exhibit high third order optical nonlinearities and fast response time, whose optical properties can be tailored by compositional changes, such as, for instance, the incorporation of metallic nanoparticles to explore plasmon resonances...

  7. Visible and ultraviolet light sources based nonlinear interaction of lasers

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer; Tidemand-Lichtenberg, Peter; Jain, Mayank;

    Different light sources can be used for optically stimulated luminescence measurements and usually a halogen lamp in combination with filters or light emitting diodes (LED’s) are used to provide the desired stimulation wavelength. However lasers can provide a much more well-defined beam, very...

  8. Nonlinear Effects of Laser Surface Modification of Ore Minerals

    Directory of Open Access Journals (Sweden)

    N.A. Leonenko

    2015-12-01

    Full Text Available The effect of continuous laser radiation on complex ore minerals objects containing gold, not extracted by monerd methods was investigated. It was established the formation of different structural surfaces of gold, revealed general patterns of sintering and concentration of sub-micron gold.

  9. Compact ultrafast semiconductor disk laser for nonlinear imaging in living organisms

    Science.gov (United States)

    Aviles-Espinosa, Rodrigo; Filippidis, G.; Hamilton, Craig; Malcolm, Graeme; Weingarten, Kurt J.; Südmeyer, Thomas; Barbarin, Yohan; Keller, Ursula; Artigas, David; Loza-Alvarez, Pablo

    2011-03-01

    Ultrashort pulsed laser systems (such as Ti:sapphire) have been used in nonlinear microscopy during the last years. However, its implementation is not straight forward as they are maintenance-intensive, bulky and expensive. These limitations have prevented their wide-spread use for nonlinear imaging, especially in "real-life" biomedical applications. In this work we present the suitability of a compact ultrafast semiconductor disk laser source, with a footprint of 140x240x70 mm, to be used for nonlinear microscopy. The modelocking mechanism of the laser is based on a quantumdot semiconductor saturable absorber mirror (SESAM). The laser delivers an average output power of 287 mW with 1.5 ps pulses at 500 MHz, corresponding to a peak power of 0.4 kW. Its center wavelength is 965 nm which is ideally suited for two-photon excitation of the widely used Green Fluorescent Protein (GFP) marker as it virtually matches its twophoton action cross section. We reveal that it is possible to obtain two photon excited fluorescence images of GFP labeled neurons and secondharmonic generation images of pharynx and body wall muscles in living C. elegans nematodes. Our results demonstrate that this compact laser is well suited for long-term time-lapse imaging of living samples as very low powers provide a bright signal. Importantly this non expensive, turn-key, compact laser system could be used as a platform to develop portable nonlinear bio-imaging devices, facilitating its wide-spread adoption in "real-life" applications.

  10. Influence of the Laser Diode Nonlinearity in Fiber-Fed Microcellular Networks

    Science.gov (United States)

    Gameiro, A.

    In this paper, the use of an optical fiber-based fixed infrastructure for code division multiple access (CDMA) mobile networks is considered. One of the major problems associated with optical subcarrier multiplexing (SCM) is the nonlinearity of the laser diodes (LD). The LD is modeled by a memoryless nonlinearity, and the effect of the nonlinearity on the SCM transmission of CDMA signals is evaluated. The behavior departs significantly from what happens in frequency division multiple access (FDMA), and depends critically on the nonlinearity being compressing or expanding. In the former case, significant performance degradation may occur, whereas for the latter this is usually not dramatic. When compared against FDMA, the major advantage of CDMA comes from the tight power control function that must be built in such systems, which means that situations of a weak signal corrupted by strong signals do not occur, unlike what happens in FDMA.

  11. Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements.

    Science.gov (United States)

    Olivier, Michel; Gagnon, Marc-Daniel; Habel, Joé

    2016-02-28

    When a laser is mode-locked, it emits a train of ultra-short pulses at a repetition rate determined by the laser cavity length. This article outlines a new and inexpensive procedure to force mode locking in a pre-adjusted nonlinear polarization rotation fiber laser. This procedure is based on the detection of a sudden change in the output polarization state when mode locking occurs. This change is used to command the alignment of the intra-cavity polarization controller in order to find mode-locking conditions. More specifically, the value of the first Stokes parameter varies when the angle of the polarization controller is swept and, moreover, it undergoes an abrupt variation when the laser enters the mode-locked state. Monitoring this abrupt variation provides a practical easy-to-detect signal that can be used to command the alignment of the polarization controller and drive the laser towards mode locking. This monitoring is achieved by feeding a small portion of the signal to a polarization analyzer measuring the first Stokes parameter. A sudden change in the read out of this parameter from the analyzer will occur when the laser enters the mode-locked state. At this moment, the required angle of the polarization controller is kept fixed. The alignment is completed. This procedure provides an alternate way to existing automating procedures that use equipment such as an optical spectrum analyzer, an RF spectrum analyzer, a photodiode connected to an electronic pulse-counter or a nonlinear detecting scheme based on two-photon absorption or second harmonic generation. It is suitable for lasers mode locked by nonlinear polarization rotation. It is relatively easy to implement, it requires inexpensive means, especially at a wavelength of 1550 nm, and it lowers the production and operation costs incurred in comparison to the above-mentioned techniques.

  12. Recent advance in target diagnostics on the Laser MégaJoule (LMJ)

    Science.gov (United States)

    Caillaud, T.; Alozy, E.; Briat, M.; Cornet, P.; Darbon, S.; Dizière, A.; Duval, A.; Drouet, V.; Fariaut, J.; Gontier, D.; Landoas, O.; Marchet, B.; Masclet-Gobain, I.; Oudot, G.; Soullié, G.; Stemmler, P.; Reverdin, C.; Rosch, R.; Rousseau, A.; Rossé, B.; Rubbelynck, C.; Troussel, P.; Villette, B.; Aubard, F.; Huelvan, S.; Maroni, R.; Llavador, P.; Allouche, V.; Burillo, M.; Chollet, C.; D'Hose, C.; Prat, B.; Trosseille, C.; Raimbourg, J.; Zuber, C.; Lebreton, J. P.; Perez, S.; Ulmer, J. L.; Jalinaud, T.; Jadaud, J. P.; Bourgade, J. L.; Wrobel, R.; Rogue, X.; Miquel, J. L.

    2016-09-01

    Since the first experimental campaign conducted in 2014 with mid field Gated X-ray Imager (GXI) and two quadruplets (20 kJ at 351 nm) focused on target, the Laser MégaJoule (LMJ) operational capability is still growing up. New plasma diagnostics have been implemented: a large field 2D GXI, two broadband x-ray spectrometers (called DMX and miniDMX), a specific soft x-ray spectrometer and a Laser Entrance Hole (LEH) imaging diagnostic. A series of experiments have been performed leading to more than 60 shots on target. We will present the plasma diagnostics development status conducted at CEA for experimental purpose. Several diagnostics are now under manufacturing or development which include a Streaked Soft X-ray Imager (SSXI), an Equation Of State (EOS) diagnostic suite ("EOS pack"), a Full Aperture BackScattering (FABS) diagnostic, a Near Backscattered Imager (NBI), a high resolution 2D GXI, a high resolution x-ray spectrometer, a specific set of two polar hard x-ray imagers for LEH characterization and a set of Neutron Time of Flight (NTOF) detectors. We describe here the diagnostics design and performances in terms of spatial, temporal and spectral resolutions. Their designs have taken into account the harsh environment (neutron yields, gamma rays, electromagnetic perturbations, debris and shrapnel) and the safety requirements.

  13. Pulsed Laser Nonlinear Thomson Scattering for General Scattering Geometries

    Energy Technology Data Exchange (ETDEWEB)

    Geoffrey Krafft; A. Doyuran; James Rosenzweig

    2005-05-01

    In a recent paper it has been shown that single electron Thomson backscatter calculations can be performed including the effects of pulsed high intensity lasers. In this paper we present a more detailed treatment of the problem and present results for more general scattering geometries. In particular, we present new results for 90 degree Thomson scattering. Such geometries have been increasingly studied as X-ray sources of short-pulse radiation. Also, we present a clearer physical basis for these different cases.

  14. Photon acceleration versus frequency-domain interferometry for laser wakefield diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dias, J.M.; Oliveira e Silva, L.; Mendonca, J.T. [GoLP/Centro de Fisica de Plasmas, Inst. Superior Tecnico, Lisbon (Portugal)

    1998-03-01

    A detailed comparison between the photon acceleration diagnostic technique and the frequency-domain interferometric technique for laser wakefield diagnostics, by using ray-tracing equations is presented here. The dispersion effects on the probe beam and the implications of an arbitrary phase velocity of the plasma wave are discussed for both diagnostic techniques. In the presence of large amplitude plasma wave and long interaction distances significant frequency shifts can be observed. The importance of this effect on the determination of the phase and frequency shifts measurements given by each of the two diagnostic techniques, is also analyzed. The accuracy of both diagnostic techniques is discussed and some of their technical problems are reviewed. (author)

  15. Effect of quantum correction on nonlinear thermal wave of electrons driven by laser heating

    Science.gov (United States)

    Nafari, F.; Ghoranneviss, M.

    2016-08-01

    In thermal interaction of laser pulse with a deuterium-tritium (DT) plane, the thermal waves of electrons are generated instantly. Since the thermal conductivity of electron is a nonlinear function of temperature, a nonlinear heat conduction equation is used to investigate the propagation of waves in solid DT. This paper presents a self-similar analytic solution for the nonlinear heat conduction equation in a planar geometry. The thickness of the target material is finite in numerical computation, and it is assumed that the laser energy is deposited at a finite initial thickness at the initial time which results in a finite temperature for electrons at initial time. Since the required temperature range for solid DT ignition is higher than the critical temperature which equals 35.9 eV, the effects of quantum correction in thermal conductivity should be considered. This letter investigates the effects of quantum correction on characteristic features of nonlinear thermal wave, including temperature, penetration depth, velocity, heat flux, and heating and cooling domains. Although this effect increases electron temperature and thermal flux, penetration depth and propagation velocity are smaller. This effect is also applied to re-evaluate the side-on laser ignition of uncompressed DT.

  16. Crystallo-optic diagnostics method of the soft laser-induced effects in biological fluids

    Science.gov (United States)

    Skopinov, S. A.; Yakovleva, S. V.

    1991-05-01

    Presently, it is well known that individual cells"2 and higher organisms3'4 exhibit a marked response to soft laser irradiation in certain parts of the visible and near infrared spectral ranges. Broad clinical applications of laser therapy and slow progress in understanding of the physical, chemical and biological mechanisms of this phenomenon make the task to search new methods of objectivisation of laser-induces bioeffects very insistent. In this paper we give a short review of the methods of structural-optical diagnostics of the soft laser-induced effects in biofluids (blood and its fractions, saliva, juices, mucuses, exudations, etc.) and suggest their applications in experimental and clinical studies of the soft laser bioeffects.

  17. Laser-based temperature diagnostics in practical combustion systems

    OpenAIRE

    Kronemayer, Helmut

    2007-01-01

    Today’s energy supply relies on the combustion of fossil fuels. This results in emissions of toxic pollutants and green-house gases that most likely influence the global climate. Hence, there is a large need for developing efficient combustion processes with low emissions. In order to achieve this, quantitative measurement techniques are required that allow accurate probing of important quantities, such as e.g. the gas temperature, in practical combustion devices. Diagnostic techniques: Ther...

  18. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Azima, Armin

    2009-07-15

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  19. Advanced ultrafast fiber laser sources enabled by fiber nonlinearities

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei

    2017-05-15

    Development of high power/energy ultrafast fiber lasers for scientific research and industrial applications is one of the most exciting fields in ultrafast optics. This thesis demonstrated new means to improve two essential properties - which are indispensable for novel applications such as high-harmonic generation (HHG) and multiphoton microscopy (MPM) - of an ultrafast fiber laser system: energy scaling capability and wavelength tunability. High photon-flux extreme ultraviolet sources enabled by HHG desire high power (>100 W), high repetition-rate (>1 MHz) ultrafast driving laser sources. We have constructed from scratch a high-power Yb-fiber laser system using the well-known chirped-pulse amplification (CPA) technique. Such a CPA system capable of producing ∝200-W average power consists of a monolithic Yb-fiber oscillator, an all-fiber stretcher, a pre-amplifier chain, a main amplifier constructed from rode-type large pitch fiber, and a diffraction-grating based compressor. To increase the HHG efficiency, ultrafast pulses with duration <60 fs are highly desired. We proposed and demonstrated a novel amplification technique, named as pre-chirp managed amplification (PCMA). We successfully constructed an Yb-fiber based PCMA system that outputs 75-MHz spectrally broadened pulses with >130-W average power. The amplified pulses are compressed to 60-fs pulses with 100-W average power, constituting a suitable HHG driving source. MPM is a powerful biomedical imaging tool, featuring larger penetration depth while providing the capability of optical sectioning. Although femtosecond solid-state lasers have been widely accepted as the standard option as MPM driving sources, fiber-based sources have received growing research efforts due to their superior performance. In the second part of this thesis, we both theoretically and experimentally demonstrated a new method of producing wavelength widely tunable femtosecond pulses for driving MPM. We employed self-phase modulation

  20. Extreme nonlinearities in InAs/InP nanowire gain media: the two-photon induced laser

    DEFF Research Database (Denmark)

    Capua, Amir; Kami, Ouri; Eisenstein, Gadi;

    2012-01-01

    We demonstrate a novel laser oscillation scheme in an InAs / InP wire-like quantum dash gain medium. A short optical pulse excites carriers by two photon absorption which relax to the energy levels providing gain thereby enabling laser oscillations. The nonlinear dynamic interaction is analyzed...... and quantified using multi-color pump-probe measurements and shows a highly efficient nonlinear two photon excitation process which is larger by more than an order of magnitude compared to common quantum well and bulk gain media. The dynamic response of the nonlinearly induced laser line is characterized...

  1. Time-resolved electron spectrum diagnostics for a free-electron laser

    NARCIS (Netherlands)

    Gillespie, W. A.; MacLeod, A. M.; Martin, P. F.; van der Meer, A. F. G.; van Amersfoort, P. W.

    1996-01-01

    Time-resolved electron-beam diagnostics have been developed for use with free-electron lasers (FELs) and associated electron sources, based on the techniques of secondary electron emission and optical transition radiation (OTR). The 32-channel OTR detector forms part of a high-resolution (0.18%) ele

  2. Terahertz Generation in Nonlinear Crystals with Mid-Infrared CO2 Laser

    Institute of Scientific and Technical Information of China (English)

    LU Yan-Zhao; WANG Xin-Bing; MIAO Liang; ZUO Du-Luo; CHENG Zu-Hai

    2011-01-01

    The terahertz(THz)generation based on difference frequency generation in nonlinear optical crystals pumped by mid-infrared C02 laser has been investigated.We present a comprehensive study of the phase-matching conditions in the GaSe, ZnGeP2 and GaAs crystals. A comparison of the characteristics of these crystals as the THz frequency generator is also presented. The investigation of the conversion efficiency shows that GaSe and GaAs are the most promising nonlinear crystals for the efficient and widely tunable THz generation.

  3. Laser-Machined Ultra-High-Q Microrod Resonators for Nonlinear Optics

    CERN Document Server

    Del'Haye, Pascal; Papp, Scott B

    2013-01-01

    Optical whispering-gallery microresonators are useful tools in microphotonics, and nonlinear optics at very low threshold powers. Here, we present details about the fabrication of ultra-high-Q whispering-gallery-mode resonators made by CO2-laser lathe machining of fused-quartz rods. The resonators can be fabricated in less than one minute and the obtained optical quality factors exceed Q = 10^9. Demonstrated resonator diameters are in the range between 170 {\\mu}m and 8 mm (free spectral ranges between 390 GHz and 8 GHz). Using these microresonators, a variety of optical nonlinearities are observed, including Raman scattering, Brillouin scattering and four-wave mixing.

  4. Nonlinear Breit-Wheeler pair production in a tightly focused laser beam

    CERN Document Server

    Di Piazza, A

    2016-01-01

    The only available analytical framework for investigating QED processes in a strong laser field systematically relies on approximating the latter as a plane wave. However, realistic high-intensity laser beams feature much more complex space-time structures than plane waves. Here, we show the feasibility of an analytical framework for investigating strong-field QED processes in laser beams of arbitrary space-time structure by determining the energy spectrum of positrons produced via nonlinear Breit-Wheeler pair production as a function of the background field. A numerical evaluation of the angular resolved positron spectrum shows significant quantitative differences with respect to the analogous result in a plane wave, such that the present results will be also important for the design of upcoming strong laser facilities aiming at measuring this process.

  5. Switchable multiwavelength fiber laser using erbium-doped twin-core fiber and nonlinear polarization rotation

    Science.gov (United States)

    Lian, Yudong; Ren, Guobin; Zhu, Bofeng; Gao, Yixiao; Jian, Wei; Ren, Wenhua; Jian, Shuisheng

    2017-05-01

    We propose and demonstrate a switchable multiwavelength fiber laser using erbium-doped twin-core fiber (ED-TCF) and nonlinear polarization rotation (NPR). The number switchability of lasing wavelengths being switched from 1 to 4 and wavelength location switchability could be achieved simultaneously in the proposed configuration with a wavelength spacing of 1.1 nm and an optical signal to noise ratio (OSNR) larger than 43 dB. The output laser powers at different wavelengths are nearly the same with a fluctuation less than 2 dB. The proposed fiber laser shows good stability with wavelength shift within 0.01 nm and peak power fluctuation less than 5 dB. The proposed fiber laser has the advantages of simple structure and stable operation.

  6. Nonlinear Breit-Wheeler Pair Production in a Tightly Focused Laser Beam

    Science.gov (United States)

    Di Piazza, A.

    2016-11-01

    The only available analytical framework for investigating QED processes in a strong laser field systematically relies on approximating the latter as a plane wave. However, realistic high-intensity laser beams feature much more complex space-time structures than plane waves. Here, we show the feasibility of an analytical framework for investigating strong-field QED processes in laser beams of arbitrary space-time structure by determining the energy spectrum of positrons produced via nonlinear Breit-Wheeler pair production as a function of the background field in the realistic assumption that the energy of the incoming photon is the largest dynamical energy in the problem. A numerical evaluation of the angular resolved positron spectrum shows significant quantitative differences with respect to the analogous result in a plane wave, such that the present results will be also important for the design of upcoming strong laser facilities aiming at measuring this process.

  7. Bifurcation and Chaos Control for Nonlinear Laser Systems

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In recent years, complexity science, including various bifurcations ,chaos and turbulence, has become a great challenge in various interdisciplinary fields. It promises to have a major impact on many aspects of nature science and engineering, even social and economic science. Candidates of complex system include coupled laser systems, accelerator-driven clean nuclear power system, neural networks, cellular automata, living organism, human brain, chemical reactions and economic systems. This new and challenging research and development area has in effect become a scientific inter-discipline itself, involving systems and control engineers, theoretical and experimental

  8. Towards Real Time Diagnostics of Hybrid Welding Laser/GMAW

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Mcjunkin; Dennis C. Kunerth; Corrie Nichol; Evgueni Todorov; Steve Levesque; Feng Yu; Robert Danna Couch

    2013-07-01

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

  9. Laser Diagnostics Study of Plasma Assisted Combustion for Scramjet Applications

    Science.gov (United States)

    2011-12-01

    treatment of the fuel or reactants into hydrogen rich syngas prior to thermal oxidation [11-12], enhanced ignition of hydrocarbon fuels [9,13-14...dramatically, and a significant rise of OH in the post combustion gas region is evident. It is 532 nm Power Supply N d: YA G L as er Dye Laser...plasma, ne~1014-1015 cm-3). The power supply is a 2 kW magnetron (2.45 GHz), although no more than 40 W seems to be required for most test conditions due

  10. Towards real time diagnostics of Hybrid Welding Laser/GMAW

    Energy Technology Data Exchange (ETDEWEB)

    McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I. [Idaho National Laboratory, Idaho Falls, ID 83415-3570 (United States); Todorov, E.; Levesque, S. [Edison Welding Institute, Columbus, OH (United States)

    2014-02-18

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

  11. Diagnostics, Modeling and Simulation: Three Keys Towards Mastering the Cutting Process with Fiber, Disk and Diode Lasers

    Science.gov (United States)

    Petring, Dirk; Molitor, Thomas; Schneider, Frank; Wolf, Norbert

    Even established laser processing technologies such as cutting are far away from being completely understood. Nevertheless, the progress in industrially available laser cutting systems and applications is quite respectable. Fiber and disk laser cutting changed from a debatable newcomer to a serious part of the business while the diode laser appears at the horizon as the next player to be reckoned. Understanding of the process and its performance are continually improved. This paper highlights results of research and development from the recent years. Some speculations, simulations, diagnostics and facts about the process, its properties and capabilities are assessed. Earlier and latest diagnostics and CALCut simulation results of laser beam cutting processes are presented.

  12. Nonlinear reflection of high-amplitude laser pulses from relativistic electron mirrors

    Science.gov (United States)

    Kulagin, V. V.; Kornienko, V. N.; Cherepenin, V. A.

    2016-04-01

    A coherent X-ray pulse of attosecond duration can be formed in the reflection of a counterpropagating laser pulse from a relativistic electron mirror. The reflection of a high-amplitude laser pulse from the relativistic electron mirror located in the field of an accelerating laser pulse is investigated by means of two-dimensional (2D) numerical simulation. It is shown that provided the amplitude of the counterpropagating laser pulse is several times greater than the amplitude of the accelerating laser pulse, the reflection process is highly nonlinear, which causes a significant change in the X-ray pulse shape and its shortening up to generation of quasi-unipolar pulses and single-cycle pulses. A physical mechanism responsible for this nonlinearity of the reflection process is explained, and the parameters of the reflected X-ray pulses are determined. It is shown that the duration of these pulses may constitute 50 - 60 as, while their amplitude may be sub-relativistic.

  13. Design process for NIF laser alignment and beam diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Grey, A., LLNL

    1998-06-09

    In a controller for an adaptive optic system designed to correct phase aberrations in a high power laser, the wavefront sensor is a discrete Hartmann-Shack design. It uses an army of lenslets (like a fly` s eye) to focus the laser into 77 spots on a CCD camera. Average local tilt of the wavefront across each lenslet changes the position of its focal spot. The system requires 0.1 pixel accuracy in determining the focal spot location. We determine a small area around each spot` s previous location. Within this area, we calculate the centroid of the light intensity in x and y. This calculation fails if the spot regions overlap. Especially during initial acquisition of a highly distorted beam, distinguishing overlapping spots is difficult. However, low resolution analysis of the overlapping spots allows the system to estimate their positions. With this estimate, it can use the deformable mirror to correct the beam enough so we can detect the spots using conventional image processing.

  14. Model for nonlinear behavior in the self-amplified spontaneous-emission free-electron laser

    Science.gov (United States)

    Krinsky, S.

    2004-06-01

    We introduce a simplified model for the saturation of a self-amplified spontaneous-emission free-electron laser. Within this model, we determine the effect of nonlinearity upon the statistical properties of the output radiation. Comparing our results with the computer simulations of Saldin, Schneidmiller, and Yurkov [The Physics of Free Electron Lasers (Springer-Verlag, Berlin, 2000)], we find that the model provides a good description of the average intensity, field correlation function, and coherence time, but underestimates the intensity fluctuation. Asymmetric spectral broadening phenomena are not included in the model.

  15. Dynamic Equations and Nonlinear Dynamics of Cascade Two-Photon Laser

    Institute of Scientific and Technical Information of China (English)

    XIE Xia; HUANG Hong-Bin; QIAN Feng; ZHANG Ya-Jun; YANG Peng; QI Guan-Xiao

    2006-01-01

    We derive equations and study nonlinear dynamics of cascade two-photon laser, in which the electromagnetic field in the cavity is driven by coherently prepared three-level atoms and classical field injected into the cavity. The dynamic equations of such a system are derived by using the technique of quantum Langevin operators, and then are studied numerically under different driving conditions. The results show thgt under certain conditions the cascade twophoton laser can generate chaotic, period doubling, periodic, stable and bistable states. Chaos can be inhibited by atomic populations, atomic coherences, and injected classical field. In addition, no chaos occurs in optical bistability.

  16. Two-beam nonlinear Kerr effect to stabilize laser frequency with sub-Doppler resolution

    CERN Document Server

    Martins, Weliton Soares; de Silans, Thierry Passerat; Oriá, Marcos; Chevrollier, Martine; 10.1364/AO.51.005080

    2012-01-01

    Avoiding laser frequency drifts is a key issue in many atomic physics experiments. Several techniques have been developed to lock the laser frequency using sub-Doppler dispersive atomic lineshapes as error signals in a feedback loop. We propose here a two-beam technique that uses non-linear properties of an atomic vapor around sharp resonances to produce sub-Doppler dispersive-like lineshapes that can be used as error signals. Our simple and robust technique has the advantage of not needing either modulation or magnetic fields.

  17. Microwave emission by nonlinear crystals irradiated with a high-intensity, mode-locked laser

    CERN Document Server

    Borghesani, A F; Guarise, M

    2016-01-01

    We report on the experimental investigation of the efficiency of some nonlinear crystals to generate microwave (RF) radiation as a result of optical rectification (OR) when irradiated with intense pulse trains delivered by a mode-locked laser at $1064\\,$nm. We have investigated lithium triborate (LBO), lithium niobate (LiNbO$_3$), zinc selenide (ZnSe), and also potassium titanyl orthophosphate (KTP) for comparison with previous measurements. The results are in good agreement with the theoretical predictions based on the form of the second-order nonlinear susceptibility tensor. For some crystals we investigated also the second harmonic generation (SHG) to cross check the theoretical model. We confirm the theoretical prediction that OR leads to the production of higher order RF harmonics that are overtones of the laser repetition rate.

  18. Complete elimination of nonlinear light-matter interactions with broadband ultrafast laser pulses

    DEFF Research Database (Denmark)

    Shu, Chuan-Cun; Dong, Daoyi; Petersen, Ian R.

    2017-01-01

    nonlinear interactions of ultrafast laser pulses with quantum systems. That is, a completely linear response of the system with respect to the spectral energy density of the incident light at the transition frequency can be obtained for all transition probabilities between 0 and 100% in multilevel quantum......The absorption of a single photon that excites a quantum system from a low to a high energy level is an elementary process of light-matter interaction, and a route towards realizing pure single-photon absorption has both fundamental and practical implications in quantum technology. Due to nonlinear...... optical effects, however, the probability of pure single-photon absorption is usually very low, which is particularly pertinent in the case of strong ultrafast laser pulses with broad bandwidth. Here we demonstrate theoretically a counterintuitive coherent single-photon absorption scheme by eliminating...

  19. Relativistic nonlinearity and wave-guide propagation of rippled laser beam in plasma

    Indian Academy of Sciences (India)

    R K Khanna; K Baheti

    2001-06-01

    In the present paper we have investigated the self-focusing behaviour of radially symmetrical rippled Gaussian laser beam propagating in a plasma. Considering the nonlinearity to arise from relativistic phenomena and following the approach of Akhmanov et al, which is based on the WKB and paraxial-ray approximation, the self-focusing behaviour has been investigated in some detail. The effect of the position and width of the ripple on the self-focusing of laser beam has been studied for arbitrary large magnitude of nonlinearity. Results indicate that the medium behaves as an oscillatory wave-guide. The self-focusing is found to depend on the position parameter of ripple as well as on the beam width. Values of critical power has been calculated for different values of the position parameter of ripple. Effects of axially and radially inhomogeneous plasma on self-focusing behaviour have been investigated and presented here.

  20. Nonlinear interaction of charged particles with strong laser pulses in a gaseous media

    Directory of Open Access Journals (Sweden)

    H. K. Avetissian

    2007-07-01

    Full Text Available The charged particles nonlinear dynamics in the field of a strong electromagnetic wave pulse of finite duration and certain form of the envelope, in the refractive medium with a constant and variable refraction indexes, is investigated by means of numerical integration of the classical relativistic equations of motion. The particle energy dependence on the pulse intensity manifests the nonlinear threshold phenomenon of a particle reflection and capture by actual laser pulses in dielectric-gaseous media that takes place for a plane electromagnetic wave in the induced Cherenkov process. Laser acceleration of the particles in the result of the reflection from the pulse envelope and in the capture regime with the variable refraction index along the pulse propagation direction is investigated.

  1. Laser cleaning of pulsed laser deposited rhodium films for fusion diagnostic mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Uccello, A., E-mail: andrea.uccello@mail.polimi.it [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Maffini, A., E-mail: alessandro.maffini@mail.polimi.it [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Dellasega, D., E-mail: david.dellasega@polimi.it [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Milan (Italy); Passoni, M., E-mail: matteo.passoni@polimi.it [Dipartimento di Energia, Politecnico di Milano, Milan (Italy); Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Milan (Italy)

    2013-10-15

    Highlights: ► Pulsed laser deposition is exploited to produce Rh films for first mirrors. ► Pulsed laser deposition is exploited to produce tokamak-like C contaminants. ► Rh laser damage threshold has been evaluated for infrared pulses. ► Laser cleaning of C contaminated Rh films gives promising results. -- Abstract: In this paper an experimental investigation on the laser cleaning process of rhodium films, potentially candidates to be used as tokamak first mirrors (FMs), from redeposited carbon contaminants is presented. A relevant issue that lowers mirror's performance during tokamak operations is the redeposition of sputtered material from the first wall on their surface. Among all the possible techniques, laser cleaning, in which a train of laser pulses is launched to the surface that has to be treated, is a method to potentially mitigate this problem. The same laser system (Q-switched Nd:YAG laser with a fundamental wavelength of 1064-nm and 7-ns pulses) has been employed with three aims: (i) production by pulsed laser deposition (PLD) of Rh film mirrors, (ii) production by PLD of C deposits with controlled morphology, and (iii) investigation of the laser cleaning method onto C contaminated Rh samples. The evaluation of Rh films laser damage threshold, as a function of fluence and number of pulses, is discussed. Then, the C/Rh films have been cleaned by the laser beam. The exposed zones have been characterized by visual inspection and scanning electron microscopy (SEM), showing promising results.

  2. Acoustic nonlinearity of narrowband laser-generated surface waves in the bending fatigue of Al6061 alloy

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Taehyung; Choi, Sungho; Lee, Taehun; Jhang, Kyungyoung; Kim, Chungseok [Hanyang University, Seoul (Korea, Republic of)

    2010-11-15

    The present study describes the acoustic nonlinearity phenomenon of a narrowband laser generated surface wave for the characterization of an aluminum alloy subjected to bending fatigue. The surface wave is very attractive for field applications because it does not require both sides of the test materials to access the transducers and has strong acoustic nonlinear effects on the surface. The intrinsic higher-order harmonic components generated by a line-arrayed laser beam have been analyzed theoretically, and a relative acoustic nonlinear parameter has been successfully measured on the surface of a fatigue-damaged aluminum 6061 alloy. The results show that the acoustic nonlinear parameter increased after fatigue damage with respect to dislocation evolution. Consequently, this study suggests that the new acoustic nonlinearity technique of a laser-generated surface wave can be potentially used to characterize surface damage resulting from bending fatigue prior to the formation of fatigue cracks.

  3. Controlling the nonlinear intracavity dynamics of large He-Ne laser gyroscopes

    CERN Document Server

    Cuccato, Davide; Belfi, Jacopo; Beverini, Nicolò; Ortolan, Antonello; Di Virgilio, Angela

    2013-01-01

    A model based on Lamb's theory of gas lasers is applied to a He-Ne ring laser gyroscope in order to estimate and remove the laser dynamics contribution from the rotation measurements. The intensities of the counter-propagating laser beams exiting one cavity mirror are continuously observed together with a monitor of the laser population inversion. These observables, once properly calibrated with a dedicated procedure, allow us to estimate cold cavity and active medium parameters driving the main part of the nonlinearities of the system. The parameters identification and noise subtraction procedure has been verified by means of a Monte Carlo study of the system, and experimentally tested on the G-Pisa ring laser oriented with the normal to the ring plane almost parallel to the Earth rotation axis. In this configuration the Earth rotation-rate provides the maximum Sagnac effect while the contribution of the orientation error is reduced at minimum. After the subtraction of laser dynamics by a Kalman filter, the ...

  4. Nonlinear neutrino-photon interactions inside strong laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Meuren, Sebastian; Keitel, Christoph H.; Di Piazza, Antonino [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2016-07-01

    As different neutrino mass eigenstates exist, only the lightest neutrino is absolutely stable. However, due to the small phase space and the GIM suppression mechanism the radiative neutrino lifetime is much larger than the age of the universe. Interestingly, the photon-emission probability by a neutrino is drastically increased in the presence of an external background field. Therefore, it is natural to ask the question whether this so-called ''electromagnetic catalysis'' could be studied in an laboratory experiment using existing and upcoming laser facilities. To shed light on this question, we derive the vector-axialvector coupling tensor in the presence of an arbitrary plane-wave background field, which is needed for the calculation of the radiative neutrino decay. Furthermore, we study the Adler-Bell-Jackiw anomaly associated with this object in detail.

  5. 非线性再生散度模型的诊断%SOME DIAGNOSTICS IN NONLINEAR REPRODUCTIVE DISPERSION MODELS

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    This article discusses the problem of the detection of influential cases in nonlinear reproductive dispersion models (NRDM). A diagnostic based on case-deletion approach in estimating equations is proposed. The relationships between the generalized leverage defined by Wei et al. in 1998, statistical curvature, and the local influence of the response vector perturbations are investigated in NRDM. Two numerical examples are given to illustrate the results.

  6. Laser patterned carbon–polyethylene mesh electrodes for wound diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Phair, Jolene; Joshi, Mayank; Benson, John; McDonald, Damian; Davis, James, E-mail: james.davis@ulster.ac.uk

    2014-02-14

    Carbon loaded polyethylene films were selected as the base substrate for a mechanically flexible and conductive sensing material for use wound monitoring technologies. The films were processed using laser ablation of the surface to increase the effective surface area of the electrode and then subject to an oxidative electrochemical etch to improve the electron transfer kinetics. The surface morphology of the resulting films was analysed and the electrode performance in relation to monitoring uric acid, a key wound biomarker, was optimized. A prototype smart bandage was designed, based on interfacing the mesh to a portable potentiostat, and the response to urate and potential interferences assessed. - Highlights: • Innovative use of a carbon–polyethylene mesh for wound sensing applications. • Electroanalytical characterisation of a mechanically flexible conductive film. • Design and preliminary characterisation of an integrated smart bandage.

  7. Lanthanide-based laser-induced phosphorescence for spray diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Voort, D. D. van der, E-mail: d.d.v.d.voort@tue.nl; Water, W. van de; Kunnen, R. P. J.; Clercx, H. J. H.; Heijst, G. J. F. van [Applied Physics Department, Eindhoven University of Technology, 5612 AZ Eindhoven (Netherlands); Maes, N. C. J.; Sweep, A. M.; Dam, N. J. [Mechanical Engineering Department, Eindhoven University of Technology, 5612 AZ Eindhoven (Netherlands); Lamberts, T. [Institute of Theoretical Chemistry, University of Stuttgart, D-70569 Stuttgart (Germany)

    2016-03-15

    Laser-induced phosphorescence (LIP) is a relatively recent and versatile development for studying flow dynamics. This work investigates certain lanthanide-based molecular complexes for their use in LIP for high-speed sprays. Lanthanide complexes in solutions have been shown to possess long phosphorescence lifetimes (∼1-2 ms) and to emit light in the visible wavelength range. In particular, europium and terbium complexes are investigated using fluorescence/phosphorescence spectrometry, showing that europium-thenoyltrifluoracetone-trioctylphosphineoxide (Eu-TTA-TOPO) can be easily and efficiently excited using a standard frequency-tripled Nd:YAG laser. The emitted spectrum, with maximum intensity at a wavelength of 614 nm, is shown not to vary strongly with temperature (293-383 K). The decay constant of the phosphorescence, while independent of ambient pressure, decreases by approximately 12 μs/K between 323 and 373 K, with the base level of the decay constant dependent on the used solvent. The complex does not luminesce in the gas or solid state, meaning only the liquid phase is visualized, even in an evaporating spray. By using an internally excited spray containing the phosphorescent complex, the effect of vaporization is shown through the decrease in measured intensity over the length of the spray, together with droplet size measurements using interferometric particle imaging. This study shows that LIP, using the Eu-TTA-TOPO complex, can be used with different solvents, including diesel surrogates. Furthermore, it can be easily handled and used in sprays to investigate spray breakup and evaporation.

  8. Study of Magnetic Domain Dynamics Using Nonlinear Magnetic Responses: Magnetic Diagnostics of the Itinerant Magnet MnP

    Science.gov (United States)

    Mito, Masaki; Matsui, Hideaki; Tsuruta, Kazuki; Deguchi, Hiroyuki; Kishine, Jun-ichiro; Inoue, Katsuya; Kousaka, Yusuke; Yano, Shin-ichiro; Nakao, Yuya; Akimitsu, Jun

    2015-10-01

    The nonlinear and linear magnetic responses to an ac magnetic field H are useful for the study of the magnetic dynamics of both magnetic domains and their constituent spins. In particular, the third-harmonic magnetic response M3ω reflects the dynamics of magnetic domains. Furthermore, by considering the ac magnetic response as a function of H, we can evaluate the degree of magnetic nonlinearity, which is closely related to M3ω. In this study, a series of approaches was used to examine the itinerant magnet MnP, in which both ferromagnetic and helical phases are present. On the basis of this investigation, we systematize the diagnostic approach to evaluating nonlinearity in magnetic responses.

  9. Stimulated Raman Scattering and Nonlinear Focusing of High-Power Laser Beams Propagating in Water

    CERN Document Server

    Hafizi, B; Penano, J R; Gordon, D F; Jones, T G; Helle, M H; Kaganovich, D

    2015-01-01

    The physical processes associated with propagation of a high-power (power > critical power for self-focusing) laser beam in water include nonlinear focusing, stimulated Raman scattering (SRS), optical breakdown and plasma formation. The interplay between nonlinear focusing and SRS is analyzed for cases where a significant portion of the pump power is channeled into the Stokes wave. Propagation simulations and an analytical model demonstrate that the Stokes wave can re-focus the pump wave after the power in the latter falls below the critical power. It is shown that this novel focusing mechanism is distinct from cross-phase focusing. While discussed here in the context of propagation in water, the gain-focusing phenomenon is general to any medium supporting nonlinear focusing and stimulated forward Raman scattering.

  10. Nonlinear mixing of Nd:YAG lasers; harmonic and sum frequency generation

    Science.gov (United States)

    Walsh, Brian M.

    2017-03-01

    Nonlinear optical materials give rise to a number of phenomena under high intensity of the incident electric field, with nonlinear mixing being a prominent example. This article discusses such nonlinear mixing processes of Nd:YAG lasers in BBO outside the more common harmonics of the 1.064 μm transition (0.532 μm, 0.366 μm and 0.266 μm). In particular, harmonics of the less common 0.946 μm transition (0.473 μm and 0.315 μm) as well as sum frequency of the 1.052 and 1.319 μm transitions (0.585 μm) and its second harmonic (0.293 μm) is discussed.

  11. Advanced femtosecond lasers enable new developments in non-linear imaging and functional studies in neuroscience, biology and medical applications (Conference Presentation)

    Science.gov (United States)

    Arrigoni, Marco; McCoy, Darryl

    2016-03-01

    In the last few years Multiphoton Excitation Microscopy witnessed a mutation from tool for imaging cellular structures in living animals deeper than other high-resolution techniques, into an instrument for monitoring functionality and even stimulating or inhibiting inter-cellular signalling. This paradigm shift has been enabled primarily by the development of genetically encoded probes like Ca indicators (GECI) and Opsins for optogenetics inhibition and stimulation. These developments will hopefully enable the understanding of how local network of hundreds or thousands of neurons operate in response to actual tasks or induced stimuli. Imaging, monitoring signals and activating neurons, all on a millisecond time scale, requires new laser tools providing a combination of wavelengths, higher powers and operating regimes different from the ones traditionally used for classic multiphoton imaging. The other key development in multiphoton techniques relates to potential diagnostic and clinical applications where non-linear imaging could provide all optical marker-free replacement of H and E techniques and even intra-operative guidance for procedures like cancer surgery. These developments will eventually drive the development of specialized laser sources where compact size, ease of use, beam delivery and cost are primary concerns. In this talk we will discuss recent laser product developments targeting the various applications of multiphoton imaging, as fiber lasers and other new type of lasers gradually gain popularity and their own space, side-by-side or as an alternative to conventional titanium sapphire femtosecond lasers.

  12. Nonlinear optical compression of high-power 10-μm CO2 laser pulses in gases and semiconductors

    Science.gov (United States)

    Pigeon, Jeremy; Tochitsky, Sergei; Joshi, Chan

    2017-03-01

    We review a series of experiments on nonlinear optical compression of high-power, picosecond, 10-µm CO2 laser pulses. Presented schemes include self-phase modulation in a Xe-filled hollow glass waveguide, self-phase modulation in GaAs followed by compression, and multiple four-wave mixing compression of a laser beat-wave in GaAs. The novel nonlinear optics and technical challenges uncovered through these experiments are discussed.

  13. Diagnostic and therapeutic applications of diode lasers and solid state lasers in medicine. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Jacques, S.L. [Texas Univ., Houston, TX (United States). Cancer Center; Welch, A.J. [Texas Univ., Austin, TX (United States); Motamedi, M. [Texas Univ., Galveston, TX (United States). Medical Branch; Rastegar, S. [Texas A and M Univ., College Station, TX (United States); Tittel, F. [Rice Univ., Houston, TX (United States); Esterowitz, L. [Naval Research Lab., Washington, DC (United States)

    1992-05-01

    The Texas Medical Center in Houston and the nearby UT Medical Branch at Galveston together constitute a major center of medical research activities. Laser applications in medicine are under development with the engineering assistance of the colloborating engineering centers at Rice University, UT-Austin, and Texas A&M Univ. In addition, this collective is collaborating with the Naval Research Laboratory, where new developments in laser design are underway, in order to transfer promising new laser technology rapidly into the medical environment.

  14. Diagnostic and therapeutic applications of diode lasers and solid state lasers in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Jacques, S.L. (Texas Univ., Houston, TX (United States). Cancer Center); Welch, A.J. (Texas Univ., Austin, TX (United States)); Motamedi, M. (Texas Univ., Galveston, TX (United States). Medical Branch); Rastegar, S. (Texas A and M Univ., College Station, TX (United States)); Tittel, F. (Rice Univ., Houston, TX (United States)); Esterowitz, L. (Naval Research Lab., Washington, DC (United States))

    1992-05-01

    The Texas Medical Center in Houston and the nearby UT Medical Branch at Galveston together constitute a major center of medical research activities. Laser applications in medicine are under development with the engineering assistance of the colloborating engineering centers at Rice University, UT-Austin, and Texas A M Univ. In addition, this collective is collaborating with the Naval Research Laboratory, where new developments in laser design are underway, in order to transfer promising new laser technology rapidly into the medical environment.

  15. Diagnostic and therapeutic applications of diode lasers and solid state lasers in medicine. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Jacques, S.L. [Texas Univ., Houston, TX (United States). Cancer Center; Welch, A.J. [Texas Univ., Austin, TX (United States); Motamedi, M. [Texas Univ., Galveston, TX (United States). Medical Branch; Rastegar, S. [Texas A and M Univ., College Station, TX (United States); Tittel, F. [Rice Univ., Houston, TX (United States); Esterowitz, L. [Naval Research Lab., Washington, DC (United States)

    1993-05-01

    The Texas Medical Center in Houston and the nearby UT Medical Branch at Galveston together constitute a major center of medical research activities. Laser applications in medicine are under development with the engineering assistance of the collaborating engineering enters at Rice University, UT-Austin, Texas A&M Univ. In addition, this collective is collaborating with the naval Research Laboratory, where new developments in laser design are underway, in order to transfer promising new laser technology rapidly into the medical environment.

  16. A diagnostic for micrometer sensitive positioning of solid targets in intense laser-matter interaction

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Prashant Kumar, E-mail: singh01@ibs.re.kr [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Kakolee, K.F. [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Jeong, T.W. [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Department of Physics and Photon Science, GIST, Gwangju 500-712 (Korea, Republic of); Ter-Avetisyan, Sargis, E-mail: sargis@ibs.re.kr [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Department of Physics and Photon Science, GIST, Gwangju 500-712 (Korea, Republic of)

    2016-09-01

    A target position monitoring diagnostic, relevant to intense laser-solid interaction, is presented. The alignment system, having a sensitivity of few micrometers, consist of an infinity corrected long working distance objective, a broadband illuminating source and a CCD camera. The imaging system, placed along the axis of incident laser pulse, serves the dual purpose of laser focus diagnosis and precise positioning of the target in three dimension axis. By employing this technique, solid targets with thickness varying from opaque micrometer thick foils to few nanometer thin transparent foils can be aligned precisely. The effectiveness of the entire alignment system is demonstrated in enhanced acceleration of ions in intense laser-matter interaction, with very high reproducibility.

  17. Structural and nonlinear optical characterizations of ZnS/ PVP nanocomposites synthesized by pulsed laser ablation

    Science.gov (United States)

    Divyasree, M. C.; Chandrasekharan, K.

    2017-05-01

    ZnS/Poly Vinyl Pyrrolidone nanocomposites were synthesized by pulsed laser ablation at ambient conditions using an Nd: YAG laser at 532 nm wavelength and 7ns pulse width. Linear optical characterizations were done using UV-Vis spectrophotometer and fluorometer. Both absorption and emission peaks were found to be blue shifted, which could be due to quantum confinement effect. Spherical morphology and the purity in the elemental composition of the sample were confirmed by scanning electron microscope and energy dispersive X-ray spectrometer respectively. Average particle size of the ZnS nanoparticles was found to be 13.45 nm from the Gaussian fitted histogram of transmission electron Microscopy image and the structure was confirmed as hexagonal wurtzite by X-ray diffraction analysis. The nonlinear optical parameters were figured out by z scan analysis with the same laser system. The nanocomposite showed good absorptive and refractive properties in the nonlinear optical regime. Detailed study of the nanocomposite revealed its potential applications in optoelectronics and nonlinear optical device fabrication.

  18. Ultrafast Laser Diagnostics for Energetic-Material Ignition Mechanisms: Tools for Physics-Based Model Development.

    Energy Technology Data Exchange (ETDEWEB)

    Kearney, Sean Patrick; Jilek, Brook Anton; Kohl, Ian Thomas; Farrow, Darcie; Urayama, Junji

    2014-11-01

    We present the results of an LDRD project to develop diagnostics to perform fundamental measurements of material properties during shock compression of condensed phase materials at micron spatial scales and picosecond time scales. The report is structured into three main chapters, which each focus on a different diagnostic devel opment effort. Direct picosecond laser drive is used to introduce shock waves into thin films of energetic and inert materials. The resulting laser - driven shock properties are probed via Ultrafast Time Domain Interferometry (UTDI), which can additionally be used to generate shock Hugoniot data in tabletop experiments. Stimulated Raman scattering (SRS) is developed as a temperature diagnostic. A transient absorption spectroscopy setup has been developed to probe shock - induced changes during shock compressio n. UTDI results are presented under dynamic, direct - laser - drive conditions and shock Hugoniots are estimated for inert polystyrene samples and for the explosive hexanitroazobenzene, with results from both Sandia and Lawrence Livermore presented here. SRS a nd transient absorption diagnostics are demonstrated on static thin - film samples, and paths forward to dynamic experiments are presented.

  19. Non-linear structural dynamics characterization using a scanning laser vibrometer

    Science.gov (United States)

    Pai, P. F.; Lee, S.-Y.

    2003-07-01

    This paper presents the use of a scanning laser vibrometer and a signal decomposition method to characterize non-linear dynamics of highly flexible structures. A Polytec PI PSV-200 scanning laser vibrometer is used to measure transverse velocities of points on a structure subjected to a harmonic excitation. Velocity profiles at different times are constructed using the measured velocities, and then each velocity profile is decomposed using the first four linear mode shapes and a least-squares curve-fitting method. From the variations of the obtained modal velocities with time we search for possible non-linear phenomena. A cantilevered titanium alloy beam subjected to harmonic base-excitations around the second, third, and fourth natural frequencies are examined in detail. Influences of the fixture mass, gravity, mass centers of mode shapes, and non-linearities are evaluated. Geometrically exact equations governing the planar, harmonic large-amplitude vibrations of beams are solved for operational deflection shapes using the multiple shooting method. Experimental results show the existence of 1:3 and 1:2:3 external and internal resonances, energy transfer from high-frequency modes to the first mode, and amplitude- and phase-modulation among several modes. Moreover, the existence of non-linear normal modes is found to be questionable.

  20. Multimodal nonlinear microscopy of biopsy specimen: towards intraoperative diagnostics (Conference Presentation)

    Science.gov (United States)

    Schmitt, Michael; Heuke, Sandro; Meyer, Tobias; Chernavskaia, Olga; Bocklitz, Thomas W.; Popp, Juergen

    2016-03-01

    The realization of label-free molecule specific imaging of morphology and chemical composition of tissue at subcellular spatial resolution in real time is crucial for many envisioned applications in medicine, e.g., precise surgical guidance and non-invasive histopathologic examination of tissue. Thus, new approaches for a fast and reliable in vivo and near in vivo (ex corpore in vivo) tissue characterization to supplement routine pathological diagnostics is needed. Spectroscopic imaging approaches are particularly important since they have the potential to provide a pathologist with adequate support in the form of clinically-relevant information under both ex vivo and in vivo conditions. In this contribution it is demonstrated, that multimodal nonlinear microscopy combining coherent anti-Stokes Raman scattering (CARS), two photon excited fluorescence (TPEF) and second harmonic generation (SHG) enables the detection of characteristic structures and the accompanying molecular changes of widespread diseases, particularly of cancer and atherosclerosis. The detailed images enable an objective evaluation of the tissue samples for an early diagnosis of the disease status. Increasing the spectral resolution and analyzing CARS images at multiple Raman resonances improves the chemical specificity. To facilitate handling and interpretation of the image data characteristic properties can be automatically extracted by advanced image processing algorithms, e.g., for tissue classification. Overall, the presented examples show the great potential of multimodal imaging to augment standard intraoperative clinical assessment with functional multimodal CARS/SHG/TPEF images to highlight functional activity and tumor boundaries. It ensures fast, label-free and non-invasive intraoperative tissue classification paving the way towards in vivo optical pathology.

  1. Laser Diagnostic Method for Plasma Sheath Potential Mapping

    Science.gov (United States)

    Walsh, Sean P.

    Electric propulsion systems are gaining popularity in the aerospace field as a viable option for long term positioning and thrusting applications. In particular, Hall thrusters have shown promise as the primary propulsion engine for space probes during interplanetary journeys. However, the interaction between propellant xenon ions and the ceramic channel wall continues to remain a complex issue. The most significant source of power loss in Hall thrusters is due to electron and ion currents through the sheath to the channel wall. A sheath is a region of high electric field that separates a plasma from a wall or surface in contact. Plasma electrons with enough energy to penetrate the sheath may result emission of a secondary electron from the wall. With significant secondary electron emission (SEE), the sheath voltage is reduced and so too is the electron retarding electric field. Therefore, a lower sheath voltage further increases the particle loss to the wall of a Hall thruster and leads to plasma cooling and lower efficiency. To further understand sheath dynamics, laser-induced fluorescence is employed to provide a non-invasive, in situ, and spatially resolved technique for measuring xenon ion velocity. By scanning the laser wavelength over an electronic transition of singly ionized xenon and collecting the resulting fluorescence, one can determine the ion velocity from the Doppler shifted absorption. Knowing the velocity at multiple points in the sheath, it can be converted to a relative electric potential profile which can reveal a lot about the plasma-wall interaction and the severity of SEE. The challenge of adequately measuring sheath potential profiles is optimizing the experiment to maximize the signal-to-noise ratio. A strong signal with low noise, enables high resolution measurements and increases the depth of measurement in the sheath, where the signal strength is lowest. Many improvements were made to reduce the background luminosity, increase the

  2. Laser-induced incandescence diagnostic for in situ monitoring of nanoparticle synthesis in an atmospheric plasma

    Science.gov (United States)

    Mitrani, James; Patel, Shane; Shneider, Mikhail; Stratton, Brent; Raitses, Yevgeny

    2014-10-01

    A DC arc discharge with a consumed graphite electrode is commonly used for synthesis of carbon nanoaparticles in a low temperature (0.1-1 eV), atmospheric pressure plasma. The formation of nanoparticles in this plasma is poorly understood; it is not clear where nanoparticles nucleate and grow in the arc discharge. Therefore, a laser-induced incandescence (LII) diagnostic for in situ monitoring of the nanoparticles' spatial distribution in the plasma is currently being constructed. The LII diagnostic involves heating the particles with a short-pulsed laser, and measuring the induced spatiotemporal incandescence profiles on longer timescales. By appropriately modeling the induced spatiotemporal incandescence profiles, one can measure particle diameters and volume fraction. LII diagnostics have been extensively used to study soot particles in flames. However, they have never been applied in a strongly coupled plasma background. Even though the spatial dimensions for soot and nanoparticles are similar, great care is needed in developing an LII diagnostic for monitoring nanoparticles in a plasma background. Therefore, we will calibrate our LII diagnostic by measuring spatiotemporal incandescence profiles of known, research grade soot and nanoparticles. This work was supported by DOE Contract DE-AC02-09CH11466.

  3. Nonlinear modal interactions in parity-time (${\\cal PT}$) symmetric lasers

    CERN Document Server

    Ge, Li

    2016-01-01

    Parity-time ($\\cal PT$) symmetric lasers have attracted considerable attention lately due to their promising applications and intriguing properties, such as free spectral range doubling and single-mode lasing. In this work we discuss nonlinear modal interactions in these laser systems under steady state conditions, and we demonstrate that several gain clamping scenarios can occur for lasing operation in the $\\cal PT$-symmetric and $\\cal PT$-broken phases. In particular, we show that, depending on the system's design and the external pump profile, its operation in the nonlinear regime falls into two different categories: in one the system is frozen in the $\\cal PT$ phase space as the applied gain increases, while in the other the system is pulled towards its exceptional point. These features are first illustrated by a coupled mode formalism and later verified by employing the Steady-state Ab-initio Laser Theory (SALT). Our findings shine light on the robustness of single-mode operation in these lasers against ...

  4. Fast spatial-resolved beam diagnostics for material processing by industrial CO2 lasers

    Science.gov (United States)

    Martinen, Dirk; Decker, Ingo; Wohlfahrt, Helmut

    1996-09-01

    Due to the increasing range of high-speed and high-accuracy applications in material processing, especially in laser beam welding and cutting, the temporal stability of the laser beam parameters becomes more and more important. In this paper a laser beam diagnostic device is presented, that allows the determination of the intensity-profiles of high- power CO2 lasers with high time-resolution. The detector of this device consists of two linear arrays of room- temperature HgCdTe-detectors, arranged perpendicularly to each other across the center of the beam. The data of the 70 detector elements is acquired simultaneously at rates up to 15 kS/sec for single shot events and several 100 kS/sec for repetitive laser pulses. Due to the use of a digital signal processor (DSP) and an especially adapted software, it is possible to analyze the fluctuations of the intensity distribution on-line. By help of a partially transmitting mirror in the beam delivery system, measurements can be performed during material processing. Therefore, the interaction of the laser beam source itself with the material processing due to beam reflection as well as influences of the industrial environment to the laser can be detected. The calculation of the local variance and mean values enables the dependence of the laser's short- and long-term stability to be investigated due to changes in the resonator alignment, the stability of the power supply, the gas composition etc., as well as to the influence of the processing. For the pulse-mode of a laser, its transient behavior like changes of the intensity distribution can be determined with high time-resolution. For the improvement of drilling processes, the calculation of further statistical functions by the DSP makes it possible to estimate the uniformity of the laser pulses on-line as well.

  5. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  6. Graphene Oxides as Tunable Broadband Nonlinear Optical Materials for Femtosecond Laser Pulses.

    Science.gov (United States)

    Jiang, Xiao-Fang; Polavarapu, Lakshminarayana; Neo, Shu Ting; Venkatesan, T; Xu, Qing-Hua

    2012-03-15

    Graphene oxide (GO) thin films on glass and plastic substrates were found to display interesting broadband nonlinear optical properties. We have investigated their optical limiting activity for femtosecond laser pulses at 800 and 400 nm, which could be tuned by controlling the extent of reduction. The as-prepared GO films were found to exhibit excellent broadband optical limiting behaviors, which were significantly enhanced upon partial reduction by using laser irradiation or chemical reduction methods. The laser-induced reduction of GO resulted in enhancement of effective two-photon absorption coefficient at 400 nm by up to ∼19 times and enhancement of effective two- and three-photon absorption coefficients at 800 nm by ∼12 and ∼14.5 times, respectively. The optical limiting thresholds of partially reduced GO films are much lower than those of various previously reported materials. Highly reduced GO films prepared by using the chemical method displayed strong saturable absorption behavior.

  7. Nonlinear interaction of charged particles with nonplane counterpropagating laser pulses of relativistic intensities

    Directory of Open Access Journals (Sweden)

    H. K. Avetissian

    2010-10-01

    Full Text Available The nonlinear threshold phenomena of particle reflection and capture of electrons in the induced Compton process that have previously been revealed in the case of plane monochromatic counterpropagating waves, take place also with the actual nonplane laser pulses of ultrashort duration and lead to particle acceleration. In contrast to analogous phenomena in the induced Cherenkov and undulator processes, the Compton reflection-capture mechanism with laser pulses of relativistic intensities practically may be realized for arbitrary initial energies of particles. The acceleration effect for particles initially in rest is explored numerically, taking into account the significance of this case connected with the relativistic electron bunches of high densities, which currently may be realized by relativistic lasers on the ultrathin solid foils where the electrons initially are almost in rest.

  8. Bragg-Scattering Four-Wave Mixing in Nonlinear Fibers with Intracavity Frequency-Shifted Laser Pumps

    Directory of Open Access Journals (Sweden)

    Katarzyna Krupa

    2012-01-01

    Full Text Available We experimentally study four-wave mixing in highly nonlinear fibers using two independent and partially coherent laser pumps and a third coherent signal. We focus our attention on the Bragg-scattering frequency conversion. The two pumps were obtained by amplifying two Intracavity frequency-shifted feedback lasers working in a continuous wave regime.

  9. Simulation of the fundamental and nonlinear harmonic output from an FEL amplifier with a soft x-ray seed laser

    Energy Technology Data Exchange (ETDEWEB)

    Biedron, S. G.; Freund, H. P.; Li, Y.; Milton, S. V.

    2000-07-05

    A single-pass, high-gain free-electron laser (FEL) x-ray amplifier was simulated using the 3D, polychromatic simulation code MEDUSA. The seed for the system is a table-top, soft x-ray laser. The simulated fundamental and nonlinear harmonic x-ray output wavelengths are discussed.

  10. Nonlinear switching in a two-concentric-core chalcogenide glass optical fiber for passively mode-locking a fiber laser.

    Science.gov (United States)

    Nazemosadat, Elham; Mafi, Arash

    2014-08-15

    We propose an all-fiber mode-locking device, which operates based on nonlinear switching in a novel two-concentric-core fiber structure. The design is particularly attractive given the ease of fabrication and coupling to other components in a mode-locked fiber laser cavity. The nonlinear switching in this coupler is studied, and the relative power transmission is obtained. The analysis shows that this nonlinear switch is practical for mode-locking fiber lasers and is forgiving to fabrication errors.

  11. High-energy resolution Thomson Parabola spectrometer for laser plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Cuttone, G.; Romano, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Maggiore, M. [Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague, Czech Republic and Laboratori Nazionali di Legnaro, INFN, Via Università 2, Legnaro (PD) (Italy); Ter-Avetisyan, S. [Laboratori Nazionali di Legnaro, INFN, Via Università 2, Legnaro (PD) (Italy); Tramontana, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and School of Mathematics and Physics, The Queen' s University Belfast, BT7 1NN (United Kingdom); Velyhan, A. [Institute of Physics of the ASCR, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic)

    2013-07-26

    Thomson Parabola (TP) spectrometers are widely used devices for laser-driven beam diagnostics as they provide a complete set of information on the accelerated particles. A novel TP has been developed at LNS with a design able to detect protons up to 20 MeV. The layout design and some results obtained during the experimental campaign at PALS laboratory will be reported in the following.

  12. Diagnostics of Femtosecond Laser-Plasmas Using Fundamental and Second Harmonic Emission

    Institute of Scientific and Technical Information of China (English)

    ZHAO Li-Zeng; ZHANG Ping; FENG Bao-Hua; WEI Zhi-Yi; ZHANG Jie

    2000-01-01

    By observing the fundamental and second harmonic emission from a plasma produced by a 150 fs, 5 mJ laser at 800nm, the electron temperature, the expansion speed and the scalelength of the plasma have been diagnosed. Moreover the polarization of the fundamental and second harmonic emission has been studied. This could be a useful diagnostic for modulation at the critical surface of the plasma.

  13. Ultrafast laser processing of transparent materials supported by in-situ diagnostics

    Science.gov (United States)

    Kumkar, M.; Kaiser, M.; Kleiner, J.; Grossmann, D.; Flamm, D.; Bergner, K.; Nolte, S.

    2016-03-01

    For the development of industrial NIR ultrafast laser processing of transparent materials, the absorption inside the bulk material has to be controlled. Applications we aim for are front and rear side ablation, drilling and inscription of modifications for cleaving and selective laser etching of glass and sapphire in sheet geometry. We applied pump probe technology and in situ stress birefringence microscopy for fundamental studies on the influence of energy and duration (100 fs - 20 ps), temporal and spatial spacing, focusing and beam shaping of the laser pulses. Applying pump probe technique we are able to visualize differences of spatio-temporal build up of absorption, self focusing, shock wave generation for standard, multispot and beam shaped focusing. Incubation effects and disturbance of beam propagation due to modifications or ablation can be observed. In-situ imaging of stress birefringence gained insight in transient build up of stress with and without translation. The results achieved so far, demonstrate that transient stress has to be taken into account in scaling the laser machining throughput of brittle materials. Furthermore it points out that transient stress birefringence is a good indicator for accumulation effects, supporting tailored processing strategies. Cutting results achieved for selective laser etching by single pass laser modification exemplifies the benefits of process development supported by in situ diagnostics.

  14. Optimizing optical nonlinearities in GaInAs/AlInAs quantum cascade lasers

    Directory of Open Access Journals (Sweden)

    Gajić Aleksandra D.

    2014-01-01

    Full Text Available Regardless of the huge advances made in the design and fabrication of mid-infrared and terahertz quantum cascade lasers, success in accessing the ~3-4 mm region of the electromagnetic spectrum has remained limited. This fact has brought about the need to exploit resonant intersubband transitions as powerful nonlinear oscillators, consequently enabling the occurrence of large nonlinear optical susceptibilities as a means of reaching desired wavelengths. In this work, we present a computational model developed for the optimization of second-order optical nonlinearities in In0.53Ga0.47As/Al0.48In0.52As quantum cascade laser structures based on the implementation of the Genetic algorithm. The carrier transport and the power output of the structure were calculated by self-consistent solutions to the system of rate equations for carriers and photons. Both stimulated and simultaneous double-photon absorption processes occurring between the second harmonic generation-relevant levels are incorporated into rate equations and the material-dependent effective mass and band non-parabolicity are taken into account, as well. The developed method is quite general and can be applied to any higher order effect which requires the inclusion of the photon density equation. [Projekat Ministarstva nauke Republike Srbije, br. III 45010

  15. Continuous-wave supercontinuum laser based on an erbium-doped fiber ring cavity incorporating a highly nonlinear optical fiber

    Science.gov (United States)

    Lee, Ju Han; Takushima, Yuichi; Kikuchi, Kazuro

    2005-10-01

    We experimentally demonstrate a novel erbium-doped fiber based continuous-wave (cw) supercontinuum laser. The laser has a simple ring-cavity structure incorporating an erbium-doped fiber and a highly nonlinear dispersion-shifted fiber (HNL-DSF). Differently from previously demonstrated cw supercontinuum sources based on single propagation of a strong Raman pump laser beam through a highly nonlinear fiber, erbium gain inside the cavity generates a seed light oscillation, and the oscillated light subsequently evolves into a supercontinuum by nonlinear effects such as modulation instability and stimulated Raman scattering in the HNL-DSF. High quality of the depolarized supercontinuum laser output with a spectral bandwidth larger than 250 nm is readily achieved.

  16. Combined medical diagnostic system with separated laser-Doppler and reflectance oximeter channels

    Science.gov (United States)

    Amzina, M. V.; Micheev, A. A.; Rogatkin, D. A.; Sidorov, V. V.

    2006-08-01

    On the basis of studying of opportunities of Reflectance Tissues Oximetry (RTO) as well as on the basis of RTO and Laser Doppler Flowmetry (LDF) comparative data, received in Moscow Regional Research and Clinical Institute "MONIKI" while patients with the peripheral blood microcirculation disorders were under examination, it was offered to unite the RTO and LDF techniques in a single diagnostic system. The new two-channel diagnostic system will contain the first LDF channel to measure the blood microcirculation parameters and the second RTO channel to register an average peripheral blood oxygenation. In the report the features of the new system design and a number of experimental data on correlation of RTO and LDF results are considered. The prospects of amalgamation of these two different techniques in a single diagnostic device are shown as well.

  17. Time-resolved electron spectrum diagnostics for a free-electron laser

    Science.gov (United States)

    Gillespie, W. A.; MacLeod, A. M.; Martin, P. F.; van der Meer, A. F. G.; van Amersfoort, P. W.

    1996-03-01

    Time-resolved electron-beam diagnostics have been developed for use with free-electron lasers (FELs) and associated electron sources, based on the techniques of secondary electron emission and optical transition radiation (OTR). The 32-channel OTR detector forms part of a high-resolution (0.18%) electron spectrometer with a time resolution of 50 ns. Variable-magnification optics allow the spectrometer to view single-macropulse spectra with widths in the range of 0.2%-7%; wider spectra are taken with several momentum settings. Design criteria for the spectrometer are presented, and experience of operating with the diagnostics over a range of FEL physics experiments is summarized. The spectrometer is used, in conjunction with optical diagnostics, in studies at FELIX of efficiency enhancement, pulse chirping, and stepped-undulator operation.

  18. First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

    Science.gov (United States)

    Rosch, R.; Trosseille, C.; Caillaud, T.; Allouche, V.; Bourgade, J. L.; Briat, M.; Brunel, P.; Burillo, M.; Casner, A.; Depierreux, S.; Gontier, D.; Jadaud, J. P.; Le Breton, J. P.; Llavador, P.; Loupias, B.; Miquel, J. L.; Oudot, G.; Perez, S.; Raimbourg, J.; Rousseau, A.; Rousseaux, C.; Rubbelynck, C.; Stemmler, P.; Troussel, P.; Ulmer, J. L.; Wrobel, R.; Beauvais, P.; Pallet, M.; Prevot, V.

    2016-03-01

    The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

  19. Design progress for the National Ignition Facility laser alignment and beam diagnostics

    Science.gov (United States)

    Bliss, Erlan S.; Boege, Steven J.; Boyd, Robert D.; Davis, Donald T.; Demaret, Robert D.; Feldman, Mark; Gates, Alan J.; Holdener, Fred R.; Knopp, Carl F.; Kyker, R. D.; Lauman, C. W.; McCarville, Tom J.; Miller, John L.; Miller-Kamm, Victoria J.; Rivera, W. E.; Salmon, J. Thaddeus; Severyn, J. R.; Sheem, Sang K.; Thomas, Stan W.; Thompson, Calvin E.; Wang, David Y.; Yoeman, M. F.; Zacharias, Richard A.; Chocol, Clifford J.; Hollis, J.; Whitaker, Daniel E.; Brucker, J.; Bronisz, L.; Sheridan, T.

    1999-07-01

    Earlier papers have described approaches to NIF alignment and laser diagnostics tasks. Now, detailed design of alignment and diagnostic systems for the National Ignition Facility (NIF) laser is in its last year. Specifications are more detailed, additional analyses have been completed, Pro- E models have been developed, and prototypes of specific items have been built. In this paper we update top level concepts, illustrate specific areas of progress, and show design implementations as represented by prototype hardware. The alignment light source network has been fully defined. It utilizes an optimized number of lasers combined with fiber optic distribution to provide the chain alignment beams, system centering references, final spatial filter pinhole references, target alignment beams, and wavefront reference beams. The input and output sensor are being prototyped. They are located respectively in the front end just before beam injection into the full aperture chain and at the transport spatial filter, where the full energy infrared beam leaves the laser. The modularity of the input sensor is improved, and each output sensor mechanical package now incorporates instrumentation for four beams.

  20. The Brief Introduction of Different Laser Diagnostics Methods Used in Aeroengine Combustion Research

    Directory of Open Access Journals (Sweden)

    Fei Xing

    2016-01-01

    Full Text Available Combustion test diagnosis has always been one of the most important technologies for the development of aerospace engineering. The traditional methods of measurement have been unable to meet the requirements of accurate capture of the flow field in the development process of the aeroengine combustor. Therefore, the development of high-precision measurement and diagnostic techniques to meet the needs of the aeroengine combustor design is imperative. Laser diagnostics techniques developed quickly in the past several years. They are used to measure the parameters of the combustion flow field such as velocity, temperature, and components concentration with high space and time resolution and brought no disturbance. Planar laser-induced fluorescence, coherent anti-Stokes Raman scattering, tunable diode laser absorption spectroscopy, and Raman scattering were introduced systemically in this paper. After analysis of their own advantages and disadvantages, the authors considered validated Raman scattering system and Tunable Diode Laser Absorption Tomography are more suitable for research activities on aeroengine combustion systems.

  1. Laser Thomson scattering diagnostics of non-equilibrium high pressure plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Muraoka, K.; Uchino, K.; Bowden, M.D.; Noguchi, Y. [Kyushu Univ., Fukuoka (Japan). Interdisciplinary Graduate School of Engineering Sciences

    2001-07-01

    For various applications of non-equilibrium high pressure plasmas, knowledge of electron properties, such as electron density, electron temperature and/or electron energy distribution function (eedf), is prerequisite for any rational approach to understanding physical and chemical processes occurring in the plasmas. For this purpose, laser Thomson scattering has been successfully applied for the first time to measure the electron properties in plasmas for excimer laser pumping and in microdischarges. Although this diagnostic technique is well established for measurements in high temperature plasmas, its applications to these glow discharge plasmas have had various inherent difficulties, such as a presence of high density neutral particles (>10{sup 21} m{sup -3}) in the excimer laser pumping discharges and an extremely small plasma size (<0.1 mm) and the presence of nearby walls for microdischarges. These difficulties have been overcome and clear signals have been obtained. The measured results are presented and their implications in the respective discharge phenomena are discussed.

  2. Cavitation bubble oscillation period as a process diagnostic during the laser shock peening process

    Science.gov (United States)

    Glaser, D.; Polese, C.

    2017-09-01

    Laser shock peening (LSP) technology is a laser-induced shock process implemented as a surface enhancement technique to introduce beneficial compressive residual stresses into metallic components. The process employs water to confine and enhance the pressure pulse delivered to the target. For thick water layers, or fully water immersed LSP, a cavitation bubble is generated by the surface vaporization of the LSP laser pulse. This research shows that the first bubble oscillation period of the cavitation bubble can be used to characterize effective and repeatable energy delivery to the target. High-speed shadowgraphy is implemented to show that variations in the bubble period occur before visual observations of dielectric breakdown in water. The diagnostic potential of the first bubble oscillation period is used to identify the dielectric breakdown threshold of water, which shows an increase with increasing water quality measured by water conductivity.

  3. Ultrasensitive standoff chemical sensing based on nonlinear multi-photon laser wave-mixing spectroscopy

    Science.gov (United States)

    Gregerson, Marc; Hetu, Marcel; Iwabuchi, Manna; Jimenez, Jorge; Warren, Ashley; Tong, William G.

    2012-10-01

    Nonlinear multi-photon laser wave mixing is presented as an ultrasensitive optical detection method for chem/bio agents in thin films and gas- and liquid-phase samples. Laser wave mixing is an unusually sensitive optical absorption-based detection method that offers significant inherent advantages including excellent sensitivity, small sample requirements, short optical path lengths, high spatial resolution, high spectral resolution and standoff remote detection capability. Wave mixing can detect trace amounts of chemicals even when using micrometer-thin samples, and hence, it can be conveniently interfaced to fibers, microarrays, microfluidic systems, lab-on-a-chip, capillary electrophoresis and other capillary- or fiber-based chemical separation systems. The wave-mixing signal is generated instantaneously as the two input laser beams intersect inside the analyte of interest. Laser excitation wavelengths can be tuned to detect multiple chemicals in their native form since wave mixing can detect both fluorescing and non-fluorescing samples at parts-pertrillion or better detection sensitivity levels. The wave-mixing signal is a laser-like coherent beam, and hence, it allows reliable and effective remote sensing of chemicals. Sensitive wave-mixing detectors offer many potential applications including sensitive detection of biomarkers, early detection of diseases, sensitive monitoring of environmental samples, and reliable detection of hazardous chem/bio agents with a standoff detection capability.

  4. Optimal Spectral Regions For Laser Excited Fluorescence Diagnostics For Point Of Care Application

    Science.gov (United States)

    Vaitkuviene, A.; Gėgžna, V.; Varanius, D.; Vaitkus, J.

    2011-09-01

    The tissue fluorescence gives the response of light emitting molecule signature, and characterizes the cell composition and peculiarities of metabolism. Both are useful for the biomedical diagnostics, as reported in previous our and others works. The present work demonstrates the results of application of laser excited autofluorescence for diagnostics of pathology in genital tissues, and the feasibility for the bedside at "point of care—off lab" application. A portable device using the USB spectrophotometer, micro laser (355 nm Nd:YAG, 0,5 ns pulse, repetition rate 10 kHz, output power 15 mW), three channel optical fiber and computer with diagnostic program was designed and ready for clinical trial to be used for cytology and biopsy specimen on site diagnostics, and for the endoscopy/puncture procedures. The biopsy and cytology samples, as well as intervertebral disc specimen were evaluated by pathology experts and the fluorescence spectra were investigated in the fresh and preserved specimens. The spectra were recorded in the spectral range 350-900 nm. At the initial stage the Gaussian components of spectra were found and the Mann-Whitney test was used for the groups' differentiation and the spectral regions for optimal diagnostics purpose were found. Then a formal dividing of spectra in the components or the definite width bands, where the main difference of the different group spectra was observed, was used to compare these groups. The ROC analysis based diagnostic algorithms were created for medical prognosis. The positive prognostic values and negative prediction values were determined for cervical Liquid PAP smear supernatant sediment diagnosis of being Cervicitis and Norma versus CIN2+. In a case of intervertebral disc the analysis allows to get the additional information about the disc degeneration status. All these results demonstrated an efficiency of the proposed procedure and the designed device could be tested at the point-of-care site or for

  5. Nonlinear Effects in Ultrasound Fields of Diagnostic-type Transducers Used for Kidney Stone Propulsion: Characterization in Water

    Science.gov (United States)

    Karzova, M.; Cunitz, B.; Yuldashev, P.; Andriyakhina, Y.; Kreider, W.; Sapozhnikov, O.; Bailey, M.; Khokhlova, V.

    2016-01-01

    Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher transducer output to provide stronger pushing force; however, nonlinear acoustic saturation effect can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match low power pressure beam scans. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging. PMID:27087711

  6. Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

    Energy Technology Data Exchange (ETDEWEB)

    Karzova, M., E-mail: masha@acs366.phys.msu.ru [Laboratoire de Mécanique des Fluides et d’Acoustique, Ecole Centrale de Lyon, 36 Avenue Guy de Collongue, 69134 Ecully (France); Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Cunitz, B.; Kreider, W.; Bailey, M. [Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40" t" h Street, Seattle, WA 98105 (United States); Yuldashev, P.; Andriyakhina, Y. [Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Sapozhnikov, O.; Khokhlova, V. [Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40" t" h Street, Seattle, WA 98105 (United States)

    2015-10-28

    Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging.

  7. Development of laser diagnostics for in situ measurements of entrained particles in recovery boilers.

    Energy Technology Data Exchange (ETDEWEB)

    Holve, Donald J. (Process Metrix LLC, San Ramon, CA); Shaddix, Christopher R.

    2004-03-01

    As part of the U.S. Department of Energy (DOE) Office of Industrial Technologies (OIT) Industries of the Future (IOF) Forest Products research program, two different laser diagnostic techniques have been implemented in pulp mill recovery boilers to provide important information on entrained particles. One technique, based on single-particle scattering of a low-power, continuous-wave (cw) laser source, measures the velocity, concentration, and size distribution of particles within the furnace flow, over a predetermined range of particle sizes. For application to recovery boilers, this technique was designed to measure the range of particle sizes known as intermediate size particles (ISPs), roughly from 2-100 {micro}m in diameter. The other diagnostic technique, known as laser-induced breakdown spectroscopy (LIBS), uses a pulsed, high-power laser beam to create a localized plasma spark in the flow, allowing the measurement of the elemental composition of the entrained particles. This technique is most sensitive for particles less than 10 {micro}m in diameter. Implementing these laser diagnostic techniques in recovery boilers proved to be challenging. For the particle scattering measurement, the use of a narrow aperture for measurement of the forward scattered light was postulated and later confirmed to be effective in minimizing background signals associated with the dense sodium fume in the boilers. For the LIBS measurement, a new water-jacketed optics probe was implemented to allow for measurements with an insertion depth of up to two meters in the furnace. Fume particle deposition on the exposed optics at the end of the LIBS probe was problematic but improved with a redesign of the probe geometry and purge flow. Both diagnostic techniques were employed at two representative recovery boilers. The particle scattering diagnostic demonstrated similar trends in mean ISP concentration, ISP size distribution, and temporal variation of ISP concentration at the two boilers

  8. Optical Nonlinear Properties of Gold Nanoparticles Synthesized by Laser Ablation in Polymer Solution

    Directory of Open Access Journals (Sweden)

    M. Tajdidzadeh

    2017-01-01

    Full Text Available In the present study, gold nanoparticles were synthesized in various polymer solutions by means of employing laser ablation technique at the same ablation time. Specifically, gold nanoparticles were synthesized in polyethylene glycol and chitosan solutions, in order to compare the effects of the liquid media which served as stabilizers for particle size and volume fraction of nanoparticles. In addition, this experiment was repeated in distilled water for reference purposes. As the findings indicated, the particle size which was obtained in polyethylene glycol was about 7.49 nm, that is, smaller than those of chitosan solution and distilled water, respectively. In contrast, it was observed that the volume fraction of gold nanoparticles increased in polyethylene glycol in comparison with the other media which indicated an effect on the formation of NPs. On the other hand, Z-scan technique was employed to measure the nonlinear refractive index and nonlinear absorption coefficient of nanofluids containing gold nanoparticles. Consequently, the nonlinear properties of nanofluids pointed to a significant contribution with the number of nanoparticles observed in fluids and both optical nonlinear parameters were observed to increase by means of a prior increase in the volume fraction of Au-NPs in polyethylene glycol solution.

  9. Theory of nonlinear harmonic generation in free-electron lasers with helical wigglers

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, G.; Saldin, E.; Schneidmiller, E.; Yurkov, M.

    2007-05-15

    CoherentHarmonicGeneration (CHG), and in particularNonlinearHarmonicGeneration (NHG), is of importance for both short wavelength Free-Electron Lasers (FELs), in relation with the achievement of shorter wavelengths with a fixed electron-beam energy, and high-average power FEL resonators, in relation with destructive effects of higher harmonics radiation on mirrors. In this paper we present a treatment of NHG from helical wigglers with particular emphasis on the second harmonic. Our study is based on an exact analytical solution of Maxwell's equations, derived with the help of a Green's function method. In particular, we demonstrate that nonlinear harmonic generation (NHG) fromhelicalwigglers vanishes on axis. Our conclusion is in open contrast with results in literature, that include a kinematical mistake in the description of the electron motion. (orig.)

  10. Nonlinear Absorptions of CdSeTe Quantum Dots under Ultrafast Laser Radiation

    Directory of Open Access Journals (Sweden)

    Zhijun Chai

    2016-01-01

    Full Text Available The oil-soluble alloyed CdSeTe quantum dots (QDs are prepared by the electrostatic method. The basic properties of synthesized CdSeTe QDs are characterized by UV-Vis absorption spectroscopy, photoluminescence spectroscopy, inductively coupled plasma mass spectrometry, and transmission electron microscope. The off-resonant nonlinear optical properties of CdSeTe QDs are studied by femtosecond Z-scan at 1 kHz (low-repetition rate and 84 MHz (high-repetition rate. Nonlinear absorption coefficients are calculated under different femtosecond laser excitations. Due to the long luminescent lifetime of CdSeTe QDs, under the conditions of high-repetition rate, for open-aperture curve, heat accumulation and bleaching of ground state are responsible for the decrease of two-photon absorption (TPA coefficient.

  11. Polarization dynamics in dissipative soliton fiber lasers mode-locked by nonlinear polarization rotation.

    Science.gov (United States)

    Kong, Lingjie; Xiao, Xiaosheng; Yang, Changxi

    2011-09-12

    We numerically studied the polarization dynamics in dissipative soliton lasers mode-locked by nonlinear polarization rotation (NPR). It was found that the polarization states of the intracavity dissipative soliton vary with time across the pulse. Depending on output coupling ratios, the polarization states of the pulse peak before the polarizer can be either nearly circular or nearly linear polarizations. The polarization dependent component in NPR is found to play a role of spectral filter under high and medium output coupling. However, NPR may work as a weak optical limiter under low output coupling, when additional spectral filtering is necessary to maintain steady mode-locking state.

  12. NONLINEAR OPTICAL FREQUENCY CONVERTER OF LASER RADIATION ON THE LBO TYPE I CRYSTALS

    Directory of Open Access Journals (Sweden)

    N. V. Kondratyuk

    2014-01-01

    Full Text Available Describes nonlinear optical frequency converter of laser radiation based on the two LBO type I crystals allowing to receive pulses of radiation at three wavelengths of 1064 nm, 532 nm and 355 nm with an adjustable pulse energy. For fine adjustment of the output pulse energy used two dual phase plates that change the orientation of the plane of polarization of the two waves in cascade third harmonic generation. Measured the efficiency of the generation of harmonics of the intensity of radiation at 1064 nm.

  13. Error Modeling, Calibration, and Nonlinear Interpolation Compensation Method of Ring Laser Gyroscope Inertial Navigation System

    Directory of Open Access Journals (Sweden)

    Jianli Li

    2013-01-01

    Full Text Available In order to improve the precision of Strapdown Inertial Navigation System (SINS and reduce the complexity of the traditional calibration method, a novel calibration and compensation scheme is proposed. An optimization calibration method with four-direction rotations is designed to calculate all error coefficients of Ring Laser Gyroscope (RLG SINS in a series of constant temperatures. According to the actual working environment, the temperature errors of RLG SINS are compensated by a nonlinear interpolation compensation algorithm. The experimental results show that the inertial navigation errors of the proposed method are reduced.

  14. Second harmonic generation of q-Gaussian laser beam in preformed collisional plasma channel with nonlinear absorption

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Naveen, E-mail: naveens222@rediffmail.com; Singh, Arvinder, E-mail: arvinder6@lycos.com [Department of Physics, National Institute of Technology Jalandhar (India); Singh, Navpreet, E-mail: navpreet.nit@gmail.com [Guru Nanak Dev University College, Kapurthala, Punjab (India)

    2015-11-15

    This paper presents a scheme for second harmonic generation of an intense q-Gaussian laser beam in a preformed parabolic plasma channel, where collisional nonlinearity is operative with nonlinear absorption. Due to nonuniform irradiance of intensity along the wavefront of the laser beam, nonuniform Ohmic heating of plasma electrons takes place. Due to this nonuniform heating of plasma, the laser beam gets self-focused and produces strong density gradients in the transverse direction. The generated density gradients excite an electron plasma wave at pump frequency that interacts with the pump beam to produce its second harmonics. The formulation is based on a numerical solution of the nonlinear Schrodinger wave equation in WKB approximation followed by moment theory approach. A second order nonlinear differential equation governing the propagation dynamics of the laser beam with distance of propagation has been obtained and is solved numerically by Runge Kutta fourth order technique. The effect of nonlinear absorption on self-focusing of the laser beam and conversion efficiency of its second harmonics has been investigated.

  15. ToF diagnostic of Tin resonant laser photoionization in SPES laser offline laboratory

    Science.gov (United States)

    Scarpa, D.; Fedorov, D.; Andrighetto, A.; Mariotti, E.; Nicolosi, P.; Sottili, L.; Tomaselli, A.; Cecchi, R.; Stiaccini, L.

    2016-09-01

    Tin is the principal element of interest in the SPES ISOL facility, which is under construction at Legnaro INFN Laboratories. Atomic nuclei have a shell structure in which nuclei with \\textquoteleft magic numbers\\textquoteright of protons and neutrons are analogous to the noble gasses in atomic physics. In particular, recent theoretical studies, reveal double-magic nature of radioactive 132Sn. For this reason the nuclear physics community demonstrated, in the last years, a huge interest to produce and study this radioactive neutron rich isotope. Experiments on Tin laser resonant ionization have been performed in the offline SPES laser laboratory to investigate the capability of the new home-made Time of Flight (ToF) mass spectrometer. Several three-step, two color ionization schemes have been tested by comparing fast and slow optogalvanic signals from a Tin Hollow Cathode Lamp (HCL) and Time of Flight signals from the spectrometer. By scanning the wavelength of one of the two dye lasers across the specific resonance, comparisons of ionization signals from both the ToF and the HCL have been made, finding perfect agreement. Furthermore, with the mass spectrometer, resolved peaks of all the natural Tin isotopes have been detected. The natural abundances extracted from these measurements are in agreement with the table values for Tin isotopes. This work, with comparison of OGE and ToF signals, confirm the fully functional SPES offline laser laboratory capability in order to develop scheme studies also for the other possible Radioactive Ion Beam (RIB) elements.

  16. Laser diagnostics of combustion phenomena related to engines/gas turbines. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Alden, Marcus [Lund Inst. of Technology (Sweden). Dept. of Combustion

    2000-05-01

    The following project has been a one year project bridging the time between the NUTEK program in 'Motorrelaterad foerbraenning' and the new STEM program in 'Energisystem i vaegfordon. The activities has included three Ph. D students and the project has been directed towards two main areas. The first area is the development and application of a new laser diagnostic technique based on laser-induced fluorescence from atomic species for measurements of two-dimensional temperatures in combustion systems. The technique has shown to have distinct advantages compared to more commonly used laser techniques and it has been applied both in engines (VOLVO PV) as well as in gas turbines (VOLVO Aero Corp.) A major advantage is the potential, recently investigated, to make measurements in sooty environments. The second area is in the area of development and application of a technique for measurements of two-dimensional soot volume fractions and particle sizes. The technique is called Laser-induced Incandescence, LII, and here a laser beam is heating the particle considerably above the flame temperature and by detecting the increased blackbody radiation, the parameters above can be inferred. During the year most work has been to develop the technique, but distinct applications in burners, engines and model fires are planned.

  17. A feasibility study of a NBI photoneutralizer based on nonlinear gating laser recirculation

    Energy Technology Data Exchange (ETDEWEB)

    Fassina, A., E-mail: alessandro.fassina@igi.cnr.it; Barbisan, M.; Pasqualotto, R. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Pretato, F.; Giudicotti, L. [Dipartimento di Ingegneria Elettrica, Università degli Studi di Padova, Via 8 Febbraio 1848, 2, 35122 Padova (Italy)

    2016-02-15

    The neutralization efficiency of negative ion neutral beam injectors is a major issue for future fusion reactors. Photon neutralization might be a valid alternative to present gas neutralizers, but still with several challenges for a valid implementation. Some concepts have been presented so far but none has been validated yet. A novel photoneutralization concept is discussed here, based on an annular cavity and a duplicated frequency laser beam (recirculation injection by nonlinear gating). The choice of lithium triborate as the material for the second harmonic extractor is discussed and a possible cooling method via crystal slicing is presented; laser intensity enhancement within the cavity is evaluated in order to quantify the achievable neutralization rate. Mockups of the critical components are proposed as intermediate steps toward system realization.

  18. Semiclassical description of nonlinear electron-positron photoproduction in strong laser fields

    CERN Document Server

    Meuren, Sebastian; Di Piazza, Antonino

    2015-01-01

    The nonlinear Breit-Wheeler process is studied in the presence of strong and short laser pulses. We show that for a relativistically intense plane-wave laser field many aspects of the momentum distribution for the produced electron-positron pair like its extend, region of highest probability and carrier-envelope phase effects can be explained from the classical evolution of the created particles in the background field. To this end we verify that the local constant-crossed field approximation is also appropriate for the calculation of the spectrum if applied on the probability-amplitude level. To compare the exact expressions with the semiclassical approach, we introduce a very fast numerical scheme, which makes it feasible to completely resolve the interference structure of the spectrum over the available multidimensional phase space.

  19. A feasibility study of a NBI photoneutralizer based on nonlinear gating laser recirculation

    Science.gov (United States)

    Fassina, A.; Pretato, F.; Barbisan, M.; Giudicotti, L.; Pasqualotto, R.

    2016-02-01

    The neutralization efficiency of negative ion neutral beam injectors is a major issue for future fusion reactors. Photon neutralization might be a valid alternative to present gas neutralizers, but still with several challenges for a valid implementation. Some concepts have been presented so far but none has been validated yet. A novel photoneutralization concept is discussed here, based on an annular cavity and a duplicated frequency laser beam (recirculation injection by nonlinear gating). The choice of lithium triborate as the material for the second harmonic extractor is discussed and a possible cooling method via crystal slicing is presented; laser intensity enhancement within the cavity is evaluated in order to quantify the achievable neutralization rate. Mockups of the critical components are proposed as intermediate steps toward system realization.

  20. Non-linear plasma effects on laser-induced terahertz emission from the atmosphere

    Science.gov (United States)

    Shin, J.-H.; Zhidkov, A.; Jin, Z.; Hosokai, T.; Kodama, R.

    2012-02-01

    Power, spectral characteristics, and angle distribution of terahertz (THz) radiation from air irradiated by a single (ω) or coupled (ω, 2ω) femtosecond laser pulses are analyzed for higher intensities, for which non-linear plasma effects on the pulse propagation become essential, by means of multidimensional particle-in-cell simulations exploiting the self-consistent plasma kinetics. THz radiation is shown to be a result of beat waves generated at ionization front with fundamental and second harmonic waves. At lower intensities, the THz power growth is far faster than the linear; at pulse intensities over I > 1015 W/cm2, the power increases slower than the linear. Along with the forward emission, strong power in around 30o angles occurs at high intensities. Ionization of air results in poor focusing of laser pulses and, therefore, lower efficiency of THz emission.

  1. Nonlinear absorption of SWNT film and its effects to the operation state of pulsed fiber laser.

    Science.gov (United States)

    Li, Xiaohui; Wang, Yonggang; Wang, Yishan; Zhao, Wei; Yu, Xuechao; Sun, Zhipei; Cheng, Xueping; Yu, Xia; Zhang, Ying; Wang, Qi Jie

    2014-07-14

    We study a single-wall carbon nanotube (SWNT) Polyvinyl alcohol (PVA) composite as a saturable absorber (SA) for pulse generation in Yb-doped fiber lasers. The saturable absorption and optical limiting (OL) characteristics of the SWNT device are investigated. By combing these two nonlinear effects, we find out for the first time, to the best of our knowledge, that mode-locking can be obtained in the dissipative soliton regime at low pumping followed by Q-switching at high pumping, which is quite different from conventional pulse dynamic evolutions. The Q-switched state operating at higher pump powers is due to the OL effect. The inverted operating fiber laser can be applied in various potential applications such as versatile material processing, optical communication and radar system etc.

  2. Green laser interferometric metrology system with sub-nanometer periodic nonlinearity.

    Science.gov (United States)

    Zhao, Shijie; Wei, Haoyun; Zhu, Minhao; Li, Yan

    2016-04-10

    This paper describes the design and realization of a heterodyne laser interferometer system that is applicable to metrology comparison. In this research, an iodine-stabilized Nd:YAG laser at 532 nm served as the light source. Two spatially separated beams with different offset frequencies are generated by two acousto-optic modulators to prevent any source mixing and polarization leakage. The interferometry components are integrated to a monolithic prism to reduce the difficulty of the light path adjustment and to guarantee the measuring accuracy. The experimental results show there is a sub-nanometer periodic nonlinearity, which mainly results from the ghost reflection. Placed in a vacuum chamber, the interferometer is applicable for measuring comparison using a piezo nanopositioner and a precision translation stage. Finally, a commercial interferometer is calibrated with the interferometer system.

  3. Measurement of the Beam Longitudinal Profile in a Storage Ring by Non-Linear Laser Mixing

    Science.gov (United States)

    Beche, J.-F.; Byrd, J.; De Santis, S.; Denes, P.; Placidi, M.; Turner, W.; Zolotorev, M.

    2004-11-01

    We report on the development of a new technique for the measurement of the longitudinal beam profile in storage rings. This technique, which has been successfully demonstrated at the Advanced Light Source, mixes the synchrotron radiation with the light from a mode-locked solid-state laser oscillator in a non-linear crystal. The up-converted radiation is then detected with a photomultiplier and processed to extract, store, and display the required information. The available choices of laser repetition frequency, pulse width, and phase modulation give a wide range of options for matching the bunch configuration of a particular storage ring. Besides the dynamic measurement of the longitudinal profile of each bunch, the instrument can monitor the evolution of the bunch tails, the presence of un trapped particles, and their diffusion into nominally empty RF buckets ("ghost bunches").

  4. Large net-normal dispersion Er-doped fibre laser mode-locked with a nonlinear amplifying loop mirror

    CERN Document Server

    Bowen, Patrick; Broderick, Neil G R

    2016-01-01

    We report on an environmentally stable, all-PM-fibre, Er-doped, mode-locked laser with a central wavelength of 1550 nm. Significantly, the laser possesses large net-normal dispersion such that its dynamics are comparable to that of an all-normal dispersion fibre laser at 1 {\\mu}m with an analogous architecture. The laser is mode-locked with a nonlinear amplifying loop mirror to produce pulses that are externally compressible to 500 fs. Experimental results are in good agreement with numerical simulations.

  5. A two-photon laser induced fluorescence diagnostic with improved sensitivity, localization, and measurement rate

    Science.gov (United States)

    Elliott, Drew; Scime, Earl; Short, Zachary

    2016-10-01

    A two-photon absorption laser induced fluorescence diagnostic has been developed for measuring neutrals in fusion plasmas. Implementation of this diagnostic on the HIT-SI3 spheromak has demonstrated the sensitivity of the diagnostic and shown that measurements taken over several plasma pulses are possible. These measurements yielded an unexpected loss of signal when complex collection optics were utilized. Simulations show that this loss of signal can be explained by chromatic aberrations caused by the disparate Kr and D emission. This loss of signal has been addressed with the development of a new calibration scheme involving xenon gas. The Xe calibration scheme emission occurs at 656.00 nm while the deuterium emission is 656.09 nm. This nearly identical emission allows for advanced optical techniques such as confocal collection/injection and spatial filtering to be employed without loss of signal. Spatial filtering has been demonstrated to decrease noise while improving measurement localization, while confocal collection/injection allows for probing and measuring to occur through one viewport. The Xe scheme also allows for a Doppler-free hydrogen measurement. Doppler-free measurements eliminate the need to scan the laser spectrally thus greatly increasing the rate of measurement.

  6. Spectroscopic diagnostics of electron temperature and energy conversion efficiency of laser-sustained plasma in flowing argon

    Science.gov (United States)

    Mazumder, J.; Krier, H.; Chen, X.

    1988-08-01

    Laser sustained plasmas are often formed during laser materials interaction. The University's 10 kW CW CO2 laser has been used to study argon plasmas for the application to laser supported propulsion and laser materials processing. The spectroscopic diagnostic method has been applied to study laser-sustained plasmas in 1 atmosphere pure argon gas flow with an f/7 on-axis laser focusing scheme. High flow speeds of 2 to 10 m/sec are achieved. Plasma electron temperatures distributions are determined from the 415.8 nm Ar1 line and its adjacent continuum intensities. Plasma core temperatures as high as 20,000 K are reported. The total absorption of the incident laser power and the radiation loss by the plasma are calculated from the temperature distribution. Results indicated that up to 86 percent of the incident laser power can be absorbed and nearly 60 percent of the incident laser power can be retained by the flowing argon gas to provide thrust. Further research is called for in the Laser Induced Fluorescence (LIF) technique for diagnostics of the downstream mixing zone and the plasma outer region. Experiments over a wider range of operating conditions, as well as multiple plasma testings, are required to find the optimum operating scheme.

  7. Role of spectroscopic diagnostics in studying nanosecond laser-plasma interaction

    Science.gov (United States)

    Burger, Miloš; Pantić, Dragan; Nikolić, Zoran; Djeniže, Stevan

    2017-05-01

    We studied the impact of varying the intensity of Nd:YAG nanosecond 1.06 μm laser radiation on the morphology and internal structure of copper plasma plumes were examined. Standard diagnostic techniques used to deduce axial distributions of electron density and temperature revealed effects of a pronounced plasma screening regime. Methods of fast imaging spectroscopy are used to examine the transition from weak- to high-screening plasma, applying irradiance on the order of 109 W cm-2 in helium atmosphere. Behavior of both ionized and neutral species was observed up to 1 μs after the laser pulse. Showing significant differences with an increase of laser irradiance, the change in plasma propagation mechanisms is attributed to internal shockwave dynamics within the plasma plume. Implications of observed behavior to plasma uniformity can affect diagnostics, and are relevant to both modeling and applications. Contribution to the Topical Issue "Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  8. Microstructure induced nonlinearity of unconsolidated rocks as related to seismic diagnostic problems

    Directory of Open Access Journals (Sweden)

    I. Yu. Belyaeva

    1997-01-01

    Full Text Available Manifestations of the so-called structure induced nonlinearity are considered for the case of a granular medium, the latter being a generally accepted model of nonconsolidated rocks in seismics. The consideration is carried out using the medium model in the form of the 'ideal' random packing of spherical elastic granules in which the interparticle space can be filled with a fluid. A physical equation of such a medium is derived; the dependencies of nonlinear parameters on the grain material elastic moduli, the fluid compressibility and the initial medium strain are analyzed. The influence of defects in nonideal grain packings (that is, the presence of a fraction of unloaded intergranular contacts upon the nonlinear properties of the medium is investigated. It is shown that the packing nonideality has the stronger effect on higher-order nonlinear properties. It is demonstrated that the nonlinear parameters may be used in exploration seismology as a much more sensitive and informative characteristic compared with conventionally used linear moduli.

  9. Dynamic model and stability analysis of a laser using a nonlinear Fabry-Perot etalon as a cavity mirror

    Energy Technology Data Exchange (ETDEWEB)

    Li, S.; Pons, R. (Autonoma de Barcelona (Spain). Dept. of Fisica); Zhang, Y. (Chongqing Inst. of Posts and Telecommunications, Sichuan (China). Telecommunications Engineering Dept.)

    1994-08-01

    In this paper, the authors study a laser using a nonlinear Fabry-Perot etalon as a cavity mirror. First, using the semiclassical laser theory and the differential equation for the lossy nonlinear Fabry-Perot etalon, they develop dynamic equations describing this system for single-mode operation. In this model, the frequency-pulling effect, a finite response time of the nonlinear medium, and a finite-cavity round-trip time of the Fabry-Perot etalon are included. Second, based on this model, they analyze the stability of this laser and give some numerical results. The results show that (1) this system can exist in the stable state and in the unstable state; (2) there are not only saddle-node bifurcations but also Hopf bifurcations; (3) the detuning parameter will effect the characteristics of the bistability and the number and distribution of Hopf bifurcation points.

  10. Propagation characteristics of a high-power broadband laser beam passing through a nonlinear optical medium with defects

    Institute of Scientific and Technical Information of China (English)

    Xueqiong; Chen; Xiaoyan; Li; Ziyang; Chen; Jixiong; Pu; Guowen; Zhang; Jianqiang; Zhu

    2013-01-01

    The intensity distributions of a high-power broadband laser beam passing through a nonlinear optical medium with defects and then propagating in free space are investigated based on the general nonlinear Schr¨odinger equation and the split-step Fourier numerical method. The influences of the bandwidth of the laser beam, the thickness of the medium,and the defects on the light intensity distribution are revealed. We find that the nonlinear optical effect can be suppressed and that the uniformity of the beam can be improved for a high-power broadband laser beam with appropriate wide bandwidth. It is also found that, under the same incident light intensity, a thicker medium will lead to a stronger self-focusing intensity, and that the influence of defects in the optical elements on the intensity is stronger for a narrowband beam than for a broadband beam.

  11. Nonlinear threshold effect in the Z-scan method of characterizing limiters for high-intensity laser light

    Science.gov (United States)

    Tereshchenko, S. A.; Savelyev, M. S.; Podgaetsky, V. M.; Gerasimenko, A. Yu.; Selishchev, S. V.

    2016-09-01

    A threshold model is described which permits one to determine the properties of limiters for high-powered laser light. It takes into account the threshold characteristics of the nonlinear optical interaction between the laser beam and the limiter working material. The traditional non-threshold model is a particular case of the threshold model when the limiting threshold is zero. The nonlinear characteristics of carbon nanotubes in liquid and solid media are obtained from experimental Z-scan data. Specifically, the nonlinear threshold effect was observed for aqueous dispersions of nanotubes, but not for nanotubes in solid polymethylmethacrylate. The threshold model fits the experimental Z-scan data better than the non-threshold model. Output characteristics were obtained that integrally describe the nonlinear properties of the optical limiters.

  12. Nonlinear interaction of intense hypergeometric Gaussian subfamily laser beams in plasma

    Science.gov (United States)

    Sobhani, H.; Vaziri (Khamedi), M.; Rooholamininejad, H.; Bahrampour, A. R.

    2016-07-01

    Propagation of Hypergeometric-Gaussian laser beam in a nonlinear plasma medium is investigated by considering the Source Dependent Expansion method. A subfamily of Hypergeometric-Gaussian beams with a non-negative, even and integer radial index, can be expressed as the linear superposition of finite number of Laguerre-Gaussian functions. Propagation of Hypergeometric-Gaussian beams in a nonlinear plasma medium depends on the value of radial index. The bright rings' number of these beams is changed during the propagation in plasma medium. The effect of beam vortex charge number l and initial (input) beam intensity on the self-focusing of Hypergeometric-Gaussian beams is explored. Also, by choosing the suitable initial conditions, Hypergeometric-Gaussian subfamily beams can be converted to one or more mode components that a typical of mode conversion may be occurred. The self-focusing of these winding beams can be used to control the focusing force and improve the electron bunch quality in laser plasma accelerators.

  13. A contribution to the development of wide band-gap nonlinear optical laser materials

    Science.gov (United States)

    Stone-Sundberg, Jennifer Leigh

    The primary focus of this work is on examining structure-property relationships of interest for high-power nonlinear optical and laser crystals. An intuitive and simply illustrated method for assessing the nonlinear optical potential of structurally characterized noncentrosymmetric materials is introduced. This method is applied to materials including common quartz and tourmaline and then extended to synthetic materials including borates, silicates, aluminates, and phosphates. Particularly, the contributions of symmetric tetrahedral and triangular anionic groups are inspected. It is shown that both types of groups significantly contribute to the optical frequency converting abilities of noncentrosymmetric crystals. In this study, several known materials are included as well as several new materials. The roles of the orientation, composition, and packing density of these anionic groups are also discussed. The structures and optical properties of the known materials BPO 4, NaAlO2, LaCa4O(BO3)3, and tourmaline; the new compounds La0.8Y0.2Sc3 (BO3)4 and Ba2B10O 17; and the laser host Sr3Y0.75Yb0.25(BO 3)3 are described.

  14. Brillouin/Raman compensation of the Kerr-effect-induced bias in a nonlinear ring laser gyroscope.

    Science.gov (United States)

    Luo, Zhang; Yuan, Xiaodong; Zhu, Zhihong; Liu, Ken; Ye, Weimin; Zeng, Chun; Ji, Jiarong

    2013-04-01

    In this Letter, the beat frequency at rest of a ring laser gyroscope with nonlinear effects is discussed in detail. Even without an additional intensity-stabilizing system, the random nullshift bias induced by the Kerr effect is compensated by the phase shift associated with the stimulated Brillouin/Raman scattering. And the nonlinear stimulated scattering also serves as the gain mechanism of the gyroscope. And thus the influence of the fluctuation of the injected pump intensity on the beat frequency is eliminated.

  15. NIR-camera-based online diagnostics of laser beam welding processes

    Science.gov (United States)

    Dorsch, Friedhelm; Braun, Holger; Keßler, Steffen; Pfitzner, Dieter; Rominger, Volker

    2012-03-01

    We have developed an on-axis camera-based online sensor system for laser beam welding diagnostics that detects the thermal radiation in the near-infrared (NIR) spectral range between 1200 and 1700 nm. In addition to a sensor in the visible (VIS) range, our camera detects the thermal radiation of the weld pool more clearly, and it is also sensible to the radiation of the solidified weld seam. The NIR images are analyzed by real-time image processing. Features are extracted from the images and evaluated to characterize the welding process. Keyhole and weld pool analysis complement VIS diagnostics, whereas the observation of the weld seam and heat affected zone with an NIR camera allows online heat flux thermography. By this means we are able to detect bad joints in overlap weldings ("false friends") online during the welding process.

  16. X-ray calibration facility for plasma diagnostics of the MégaJoule laser

    Directory of Open Access Journals (Sweden)

    Hubert S.

    2013-11-01

    Full Text Available The Laser MégaJoule (LMJ located at CEA-CESTA will be equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors and cameras. To guarantee LMJ measurements, detectors such as x-ray cameras need to be regularly calibrated. An x-ray laboratory is devoted to this task and performs absolute x-ray calibrations for similar x-ray cameras running on Laser Integration Line (LIL. This paper presents the x-ray calibration bench with its x-ray tube based High Energy x-ray Source (HEXS and some calibration results. By mean of an ingenious transposition system under vacuum absolute x-ray calibration of x-ray cameras, like streak and stripline ones, can be carried out. Coupled to a new collimation system with micrometric accuracy on aperture sensitivity quantum efficiency measurements can be achieved with reduced uncertainties.

  17. Experimental investigation by laser ultrasonics for high speed train axle diagnostics.

    Science.gov (United States)

    Cavuto, A; Martarelli, M; Pandarese, G; Revel, G M; Tomasini, E P

    2015-01-01

    The present paper demonstrates the applicability of a laser-ultrasonic procedure to improve the performances of train axle ultrasonic inspection. The method exploits an air-coupled ultrasonic probe that detects the ultrasonic waves generated by a high-power pulsed laser. As a result, the measurement chain is completely non-contact, from generation to detection, this making it possible to considerably speed up inspection time and make the set-up more flexible. The main advantage of the technique developed is that it works in thermo-elastic regime and it therefore can be considered as a non-destructive method. The laser-ultrasonic procedure investigated has been applied for the inspection of a real high speed train axle provided by the Italian railway company (Trenitalia), on which typical fatigue defects have been expressly created according to standard specifications. A dedicated test bench has been developed so as to rotate the axle with the angle control and to speed up the inspection of the axle surface. The laser-ultrasonic procedure proposed can be automated and is potentially suitable for regular inspection of train axles. The main achievements of the activity described in this paper are: – the study of the effective applicability of laser-ultrasonics for the diagnostic of train hollow axles with variable sections by means of a numerical FE model, – the carrying out of an automated experiment on a real train axle, – the analysis of the sensitivity to experimental parameters, like laser source – receiving probe distance and receiving probe angular position, – the demonstration that the technique is suitable for the detection of surface defects purposely created on the train axle. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Nonlinear data-driven identification of polymer electrolyte membrane fuel cells for diagnostic purposes: A Volterra series approach

    Science.gov (United States)

    Ritzberger, D.; Jakubek, S.

    2017-09-01

    In this work, a data-driven identification method, based on polynomial nonlinear autoregressive models with exogenous inputs (NARX) and the Volterra series, is proposed to describe the dynamic and nonlinear voltage and current characteristics of polymer electrolyte membrane fuel cells (PEMFCs). The structure selection and parameter estimation of the NARX model is performed on broad-band voltage/current data. By transforming the time-domain NARX model into a Volterra series representation using the harmonic probing algorithm, a frequency-domain description of the linear and nonlinear dynamics is obtained. With the Volterra kernels corresponding to different operating conditions, information from existing diagnostic tools in the frequency domain such as electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis (THDA) are effectively combined. Additionally, the time-domain NARX model can be utilized for fault detection by evaluating the difference between measured and simulated output. To increase the fault detectability, an optimization problem is introduced which maximizes this output residual to obtain proper excitation frequencies. As a possible extension it is shown, that by optimizing the periodic signal shape itself that the fault detectability is further increased.

  19. Efficiency enhancement of a two-beam free-electron laser using a nonlinearly tapered wiggler

    Institute of Scientific and Technical Information of China (English)

    Maryam Zahedian; B.Maraghechi; M.H.Rouhani

    2012-01-01

    A nonlinear and non-averaged model of a two-beam free-electron laser (FEL) wiggler that is tapered nonlinearly in the absence of slippage is presented.The two beams are assumed to have different energies,and the fundamental resonance of the higher energy beam is at the third harmonic of the lower energy beam.By using Maxwell's equations and the full Lorentz force equation of motion for the electron beams,coupled differential equations are derived and solved numerically by the fourth-order Runge-Kutta method.The amplitude of the wiggler field is assumed to decrease nonlinearly when the saturation of the third harmonic occurs.By simulation,the optimum starting point of the tapering and the slopes for reducing the wiggler amplitude are found.This technique can be applied to substantially improve the efficiency of the two-beam FEL in the XUV and X-ray regions.The effect of tapering on the dynamical stability of the fast electron beam is also studied.

  20. Statistical analysis of polarizing maps of blood plasma laser images for the diagnostics of malignant formations

    Science.gov (United States)

    Ungurian, V. P.; Ivashchuk, O. I.; Ushenko, V. O.

    2012-01-01

    This work is aimed at searching the interconnections between the statistic structure of blood plasma microscopic images and manifestations of optical anisotropy of liquid crystal protein network. The model of linear birefringence of albumin and globulin crystals underlies in the ground of this work. The results of investigating the interrelation between statistical moments of the 1st-4th order are presented that characterize the coordinate distributions of polarization ellipticity of laser images of blood plasma smears and pathological changes in human organism. The diagnostic criteria of breast cancer nascency and its severity degree differentiation are determined.

  1. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Science.gov (United States)

    Kuznetsov, Yu L.; Kalchenko, V. V.; Astaf'eva, N. G.; Meglinski, I. V.

    2014-08-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials.

  2. Diesel combustion: an integrated view combining laser diagnostics, chemical kinetics, and empirical validation

    Energy Technology Data Exchange (ETDEWEB)

    Akinyami, O C; Dec, J E; Durrett, R P; Flynn, P F; Hunter, G L; Loye, A O; Westbrook, C

    1999-02-01

    This paper proposes a structure for the diesel combustion process based on a combination of previously published and new results. Processes are analyzed with proven chemical kinetic models and validated with data from production-like direct injection diesel engines. The analysis provides new insight into the ignition and particulate formation processes, which combined with laser diagnostics, delineates the two-stage nature of combustion in diesel engines. Data are presented to quantify events occurring during the ignition and initial combustion processes that form soot precursors. A framework is also proposed for understanding the heat release and emission formation processes.

  3. Triple-wavelength switchable multiwavelength erbium-doped fiber laser based on a highly nonlinear photonic crystal fiber

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young-Geun [Hanyang University, Seoul (Korea, Republic of)

    2010-04-15

    We propose and experimentally investigate a novel scheme for a triple-wavelength switchable multiwavelength erbium-doped fiber laser based on a highly nonlinear photonic crystal fiber incorporating a multiply-phase-shifted fiber Bragg grating. A nonlinear optical loop mirror based on a highly nonlinear photonic crystal fiber is exploited to suppress the homogeneous line broadening of an erbium-doped fiber amplifier and to provide the triple lasing wavelength switchability. A multiply phase-shifted fiber Bragg grating with three channels, depending on the number of phase-shifted segments, is implemented to establish a multichannel filter and to generate the multiwavelength output. A high-quality multiwavelength output with a high extinction ratio of {approx}45 dB and a high output flatness of {approx}0.3 dB is realized. The switching performance to provide lasing-wavelength selectivity can be realized by using a nonlinear polarization rotation based on a nonlinear optical loop mirror. The lasing wavelength can be switched individually by controlling both the polarization controller within the nonlinear optical loop mirror and the cavity loss. The proposed multiwavelength fiber laser can be operated in the single-, dual-, and triple-lasing wavelength states. Based on the bending technique, the lasing wavelength of the proposed multiwavelength erbium-doped fiber laser can be readily controlled, and its tunability was measured to be {approx}7.2 nm/m{sup -1}.

  4. Laser linewidth and fiber nonlinearity tolerance study of C-16QAM compared to square 16QAM in coherent OFDM system

    Science.gov (United States)

    Xu, Fei; Qiao, Yaojun; Zhou, Ji; Guo, Mengqi; Tian, Huiping

    2017-03-01

    We introduced an effective modulation format circle 16 quadrature amplitude modulation (C-16QAM) to improve the laser linewidth induced phase noise and fiber nonlinear effects tolerance in coherent orthogonal frequency division multiplexing (OFDM) system without other losses compared to square 16QAM. Although C-16QAM has improved the performance of single channel system with Viterbi-Viterbi carrier phase estimation, C-16QAM using in coherent OFDM system has not been performed and such configuration of system may solve many problems in the next generation access networks. Here we numerically studied two separate manifestations of phase noise generated by laser linewidth and fiber nonlinear effects. We take these two kinds of phase noise into consideration separately by investigating the influence of laser linewidth with fixed launch power into transmission fiber and the influence of fiber nonlinear effects with fixed laser linewidth. We find that the C-16QAM improves the laser linewidth induced phase noise significantly and improves fiber nonlinear effects tolerance to a certain degree compared to square 16QAM. This coherent C-16QAM OFDM system may have great prospects for the next generation access networks for these significantly improvements.

  5. Ion Acceleration via "Nonlinear Vacuum Heating" by the Laser Pulse Obliquely Incident on a Thin Foil Target

    CERN Document Server

    Yogo, A; Mori, M; Ogura, K; Esirkepov, T Zh; Pirozhkov, A S; Kanasaki, M; Sakaki, H; Fukuda, Y; Bolton, P R; Nishimura, H; Kondo, K

    2015-01-01

    Dependence of the energy of ions accelerated during interaction of the laser pulse obliquelly incident on the thin foil target on the laser polarization is studied experimentally and theoretically. We found that the ion energy being maximal for the p-polarization gradually decreases when the pulse becomes s-polarized. The experimentally found dependences of the ion energy are explained by invoking the anomalous electron heating which results in high electrostatic potential formation at the target surface. Anomalous heating of electrons beyond the energy of quiver motion in the laser field is described within the framework of theoretical model of driven oscillator with a step-like nonlinearity. We have demonstrated that the electron anomalous heating can be realized in two regimes: nonlinear resonance and stochastic heating, depending on the extent of stochasticity. We have found the accelerated ion energy scaling determined by the laser intensity, pulse duration, polarization angle and incident angle.

  6. A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak.

    Science.gov (United States)

    Xiong, C Y; Chen, J; Li, Q; Liu, Y; Gao, L

    2014-12-01

    A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (∼100-∼500 kHz/10 min) and decay of laser power (∼10%-∼20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.

  7. A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak

    Science.gov (United States)

    Xiong, C. Y.; Chen, J.; Li, Q.; Liu, Y.; Gao, L.

    2014-12-01

    A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (˜100-˜500 kHz/10 min) and decay of laser power (˜10%-˜20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.

  8. Nonlinear optical properties of near-infrared region Ag2S quantum dots pumped by nanosecond laser pulses

    Directory of Open Access Journals (Sweden)

    Li-wei Liu

    2015-08-01

    Full Text Available This study investigates near-infrared region Ag2S quantum dots (QDs and their nonlinear optical response under 532 nm nanosecond laser pulses. Our experimental result shows that nonlinear transmission is reduced from 0.084 to 0.04. The observed narrowing behavior of the output pulse width shows superior optical limiting. We discuss the physical mechanisms responsible for the nonlinear optical response of the QDs. The average size of the nanocrystals was 5.5 nm. Our results suggest the possibility of using these Ag2S QDs for photoelectric, biosensor, optical ranging, and self-adaptive technologies.

  9. Nonlinear interactions between the pumping kinetics, fluid dynamics and optical resonator of cw fluid flow lasers. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Sentman, L.H.; Nayfeh, M.H.

    1983-12-01

    This research is an integrated theoretical and experimental investigation of the nonlinear interactions which may occur between the chemical kinetics, the fluid dynamics and the unstable resonator of a continuous wave fluid flow laser. The objectives of this grant were to measure the frequency and amplitude of the time dependent pulsations in the power spectral output which have been predicted to occur in cw chemical lasers employing unstable resonators to extract power.

  10. Nonlinear resonances in a multi-stage free-electron laser amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, S. [Graduate Univ. for Advanced Studies, Ibaraki-ken (Japan); Takayama, K. [National Lab. for High Energy Physics, Ibaraki-ken (Japan)

    1995-12-31

    A two-beam accelerator (TBA) is a possible candidate of future linear colliders, in which the demanded rf power is provided by a multi-stage free-electron laser (MFEL). After if amplification in each stage, a driving beam is re-accelerated by an induction unit and propagates into the next stage. Recently it has been recognized that the multi-stage character of the MFEL causes resonances between its periodicity and the synchrotron motion in an rf bucket. Since the synchrotron oscillation is strongly modulated by the resonance and at the worst a large fraction of particles is trapped in the resonance islands, the nonlinear resonances in the FEL longitudinal beam dynamics can lead to notable degradation of the MFEL performance, such as output fluctuation and phase modulation which have been big concerns in the accelerator society. The overall efficiency of the MFEL and the quality of the amplified microwave power are key issues for realizing the TBA/FEL Particularly the rf phase and amplitude errors must be maintained within tolerance. One of significant obstacles is an amplification of undesired modes. If a small-size waveguide is employed, the FEL resonance energies for undesired higher order modes shift very far from that for a fundamental mode; so it is possible to prevent higher order modes from evolving. Such a small-size waveguide, however, gives a high power density in the FEL. Simulation results have demonstrated that the nonlinear resonances occur in die FEL longitudinal motion when the power density exceeds some threshold. An analytical method for studying the nonlinear resonance in the TBA/FEL is developed based on the macroparticle model which can describe analytically the drastic behaviors in the evolutions of the phase and amplitude. In the theory the basic 1D-FEL equations are reduced to a nonlinear pendulum equation with respect to the ponderomotive phase.

  11. High stable, high efficient ultraviolet laser with angle-phase-mismatching compensation by adjusting temperature of the nonlinear crystals

    Science.gov (United States)

    Yang, Houwen; Wang, Bo; Wang, Junhua; Li, Xiaofang; Liu, Zhaojun; Cheng, Wenyong

    2017-03-01

    We demonstrated an ultraviolet laser at 355 nm using a type-I and a type-II phase-matching nonlinear optical crystal of LiB3O5 (LBO). A method of adjusting temperature for compensation is presented. The crystal temperature is controlled by proportional integral derivative (PID) thermal controllers with a  ±0.01 °C resolution. The value of wave vector mismatch, distance of light propagation in nonlinear crystals, effective nonlinear coefficient, theoretical analysis and calculation of conversion efficiency versus temperature are discussed. The experimental results show that the average output power of the 355 nm laser is 1.24 W with the pump power of 13.33 W, when the repetition frequency is 15 kHz. The pulse duration is 9.8 ns, and the beam quality factors are of Mx2   =  1.8, My2   =  1.7. The conversion efficiency from 808 nm to 355 nm laser is 9.3%, which nearly reaches the optimum value reported so far and is limited by the wavelength mismatch between the pumping and absorbing lasers. The 355 nm output power instability of the laser device is 0.45% in 2 h. A compact no-water-cooling ultraviolet laser with high stability and high efficiency is obtained.

  12. A high repetition rate transverse beam profile diagnostic for laser-plasma proton sources

    Science.gov (United States)

    Dover, Nicholas; Nishiuchi, Mamiko; Sakaki, Hironao; Kando, Masaki; Nishitani, Keita

    2016-10-01

    The recently upgraded J-KAREN-P laser can provide PW peak power and intensities approaching 1022 Wcm-2 at 0.1 Hz. Scaling of sheath acceleration to such high intensities predicts generation of protons to near 100 MeV, but changes in electron heating mechanisms may affect the emitted proton beam properties, such as divergence and pointing. High repetition rate simultaneous measurement of the transverse proton distribution and energy spectrum are therefore key to understanding and optimising the source. Recently plastic scintillators have been used to measure online proton beam transverse profiles, removing the need for time consuming post-processing. We are therefore developing a scintillator based transverse proton beam profile diagnostic for use in ion acceleration experiments using the J-KAREN-P laser. Differential filtering provides a coarse energy spectrum measurement, and time-gating allows differentiation of protons from other radiation. We will discuss the design and implementation of the diagnostic, as well as proof-of-principle results from initial experiments on the J-KAREN-P system demonstrating the measurement of sheath accelerated proton beams up to 20 MeV.

  13. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Directory of Open Access Journals (Sweden)

    Łukasz Ciupiński

    2010-05-01

    Full Text Available Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses. The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in Łódź, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys. Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories.

  14. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Science.gov (United States)

    Ciupiński, Łukasz; Fortuna-Zaleśna, Elżbieta; Garbacz, Halina; Koss, Andrzej; Kurzydłowski, Krzysztof J.; Marczak, Jan; Mróz, Janusz; Onyszczuk, Tomasz; Rycyk, Antoni; Sarzyński, Antoni; Skrzeczanowski, Wojciech; Strzelec, Marek; Zatorska, Anna; Żukowska, Grażyna Z.

    2010-01-01

    Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses). The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in ŁódŸ, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys). Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu) and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories. PMID:22399915

  15. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Welzel, S [INP-Greifswald, 17489 Greifswald, Felix-Hausdorff-Str. 2 (Germany); Rousseau, A [Laboratoire de Physique et Technologie des Plasmas, Ecole Polytechnique, CNRS, 91128 Palaiseau (France); Davies, P B [Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW (United Kingdom); Roepcke, J [INP-Greifswald, 17489 Greifswald, Felix-Hausdorff-Str. 2 (Germany)

    2007-10-15

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 {mu}m, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared.

  16. X-ray optical diagnostic of laser produced plasmas for nuclear fusion and X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Butzbach, R.

    2001-07-01

    In the present work, the conception, design and appliance of toroidally bent crystals for the X-ray optical diagnostics of laser produced plasmas is discussed. The first part of this work deals with the development, design and characterization of an X-Ray microscope for the observation of Rayleigh-Taylor instabilities, which act against the confinement and ignition of the fuel in the inertial confinement fusion process. The aim of the second part of the present work was the diagnostic of the lasing medium for amplified spontaneous emission close to the water window. For this purpose, an one-dimensionally (1-D) imaging X-ray spectrometer based on toroidally bent quartz crystals was developed for the observation of the Ni-like 4f-3d transition of Yb, Hf, Ta, and W ions, which should be related to the amplified 4d-4p emission, since the 4f niveau is very close to the 4d niveau. Thus, the 4f-3d transition can serve as an indicator for the population of the 4d niveau. (orig.)

  17. Multi-Wavelength Erbium-Doped Fibre Lasers on Assistance of High-Nonlinear Photonic-Crystal Fibre

    Institute of Scientific and Technical Information of China (English)

    LIU Xue-Ming; ZHAO Wei; ZHANG Tong-Yi; LU Ke-Qing; SUN Chuan-Dong; WANG Yi-Shan; OUYANG Xian; HOU Xun; CHEN Guo-Fu

    2006-01-01

    @@ On the basis of self-stability effect of four-wave mixings (FWMs) in high-nonlinear photonic-crystal fibres, a novel multi-wavelength erbium-doped fibre (EDF)laser is proposed and demonstrated experimentally at room temperature. The proposed lasers have the capacity of switching and tuning with excellent uniformity and stability. By means of adjusting the attenuators, the triple-, four-, or five-wavelength EDF lasers can be lasing simultaneously.With the assistance of the FWM self-stability function, the multi-wavelength spectrum is excellently stabilized with uniformity less than 0.9dB.

  18. Nonlinear distortion evaluation in a directly modulated distributed feedback laser diode-based fiber-optic cable television transport system

    Science.gov (United States)

    Li, Chung-Yi; Ying, Cheng-Ling; Lin, Chun-Yu; Chu, Chien-An

    2015-12-01

    This study evaluated a directly modulated distributed feedback (DFB) laser diode (LD) for cable TV systems with respect to carrier-to-nonlinear distortion of LDs. The second-order distortion-to-carrier ratio is found to be proportional to that of the second-order coefficient-to-first-order coefficient of the DFB laser diode driving current and to the optical modulation index (OMI). Furthermore, the third-order distortion-to-carrier ratio is proportional to that of the third-order coefficient-to-first-order coefficient of the DFB laser diode driving current, and to the OMI2.

  19. Tunable and switchable dual-wavelength Tm-doped mode-locked fiber laser by nonlinear polarization evolution.

    Science.gov (United States)

    Yan, Zhiyu; Li, Xiaohui; Tang, Yulong; Shum, Perry Ping; Yu, Xia; Zhang, Ying; Wang, Qi Jie

    2015-02-23

    We propose and demonstrate a tunable and switchable dual-wavelength ultra-fast Tm-doped fiber laser. The tunability is based on nonlinear polarization evolution (NPE) technique in a passively mode-locked laser cavity. The NPE effect induces wavelength-dependent loss in the cavity to effectively alleviate mode competition and enables the multiwavelength mode locking. The laser exhibits tunable dual-wavelength mode locking over a wide range from 1852 to 1886 nm. The system has compact structure and both the wavelength tuning and switching capabilities can be realized by controlling the polarization in the fiber ring cavity.

  20. Generation of 8-nJ pulses from a dissipative-soliton fiber laser with a nonlinear optical loop mirror

    Science.gov (United States)

    Zhao, L. M.; Bartnik, A. C.; Tai, Q. Q.; Wise, F. W.

    2013-01-01

    Theoretical and experimental investigations of the behavior of normal-dispersion fiber lasers with nonlinear-optical loop mirrors are presented. The use of a loop mirror causes the laser to generate relatively long, flat-topped pulses. The pulse energy can be high, but the pulse duration is limited to greater than 300 fs. Experimentally, 8-nJ pulses that can be dechirped to 340 fs duration are obtained. The laser is a step toward an all-fiber, environmentally-stable design. PMID:23722797

  1. Next generation of optical diagnostics for bladder cancer using probe-based confocal laser endomicroscopy

    Science.gov (United States)

    Liu, Jen-Jane; Chang, Timothy C.; Pan, Ying; Hsiao, Shelly T.; Mach, Kathleen E.; Jensen, Kristin C.; Liao, Joseph C.

    2012-02-01

    Real-time imaging with confocal laser endomicroscopy (CLE) probes that fit in standard endoscopes has emerged as a clinically feasible technology for optical biopsy of bladder cancer. Confocal images of normal, inflammatory, and neoplastic urothelium obtained with intravesical fluorescein can be differentiated by morphologic characteristics. We compiled a confocal atlas of the urinary tract using these diagnostic criteria to be used in a prospective diagnostic accuracy study. Patients scheduled to undergo transurethral resection of bladder tumor underwent white light cystoscopy (WLC), followed by CLE, and histologic confirmation of resected tissue. Areas that appeared normal by WLC were imaged and biopsied as controls. We imaged and prospectively analyzed 135 areas in 57 patients. We show that CLE improves the diagnostic accuracy of WLC for diagnosing benign tissue, low and high grade cancer. Interobserver studies showed a moderate level of agreement by urologists and nonclinical researchers. Despite morphologic differences between inflammation and cancer, real-time differentiation can still be challenging. Identification of bladder cancer-specific contrast agents could provide molecular specificity to CLE. By using fluorescently-labeled antibodies or peptides that bind to proteins expressed in bladder cancer, we have identified putative molecular contrast agents for targeted imaging with CLE. We describe one candidate agent - anti-CD47 - that was instilled into bladder specimens. The tumor and normal urothelium were imaged with CLE, with increased fluorescent signal demonstrated in areas of tumor compared to normal areas. Thus, cancer-specificity can be achieved using molecular contrast agents ex vivo in conjunction with CLE.

  2. New exact solutions of nonlinear Gross-Pitaevskii equation with weak bias magnetic and time-dependent laser fields

    Institute of Scientific and Technical Information of China (English)

    Li Hua-Mei

    2005-01-01

    By using the mapping method and an appropriate transformation, we find new exact solutions of nonlinear Gross-Pitaevskii equation with weak bias magnetic and time-dependent laser fields. The solutions obtained in this paper include Jacobian elliptic function solutions, combined Jacobian elliptic function solutions , triangular function solutions, bright and dark solitons, and soliton-like solutions.

  3. Characterization of a self-starting, passively mode-locked fiber ring laser that exploits nonlinear polarization evolution.

    Science.gov (United States)

    Matsas, V J; Richardson, D J; Newson, T P; Payne, D N

    1993-03-01

    A full characterization of a self-starting, passively mode-locked soliton ring fiber laser in terms of its various modes of mode-locked operation, cavity length, and type of fiber used is presented. Direct evidence, based on state-of-polarization measurements, that nonlinear polarization evolution is the responsible mode-locking mechanism is also given.

  4. Continuous-wave to pulse regimes for a family of passively mode-locked lasers with saturable nonlinearity

    Science.gov (United States)

    Dikandé, Alain M.; Voma Titafan, J.; Essimbi, B. Z.

    2017-10-01

    The transition dynamics from continuous-wave to pulse regimes of operation for a generic model of passively mode-locked lasers with saturable absorbers, characterized by an active medium with non-Kerr nonlinearity, are investigated analytically and numerically. The system is described by a complex Ginzburg–Landau equation with a general m:n saturable nonlinearity (i.e {I}m/{(1+{{Γ }}I)}n, where I is the field intensity and m and n are two positive numbers), coupled to a two-level gain equation. An analysis of stability of continuous waves, following the modulational instability approach, provides a global picture of the self-starting dynamics in the system. The analysis reveals two distinct routes depending on values of the couple (m, n), and on the dispersion regime: in the normal dispersion regime, when m = 2 and n is arbitrary, the self-starting requires positive values of the fast saturable absorber and nonlinearity coefficients, but negative values of these two parameters for the family with m = 0. However, when the spectral filter is negative, the laser can self-start for certain values of the input field and the nonlinearity saturation coefficient Γ. The present work provides a general map for the self-starting mechanisms of rare-earth doped figure-eight fiber lasers, as well as Kerr-lens mode-locked solid-state lasers.

  5. Diagnostics of recombining laser plasma parameters based on He-like ion resonance lines intensity ratios

    Science.gov (United States)

    Ryazantsev, S. N.; Skobelev, I. Yu; Faenov, A. Ya; Pikuz, T. A.; Grum-Grzhimailo, A. N.; Pikuz, S. A.

    2016-11-01

    While the plasma created by powerful laser expands from the target surface it becomes overcooled, i.e. recombining one. Improving of diagnostic methods applicable for such plasma is rather important problem in laboratory astrophysics nowadays because laser produced jets are fully scalable to young stellar objects. Such scaling is possible because of the plasma hydrodynamic equations invariance under some transformations. In this paper it is shown that relative intensities of the resonance transitions in He-like ions can be used to measure the parameters of recombining plasma. Intensity of the spectral lines corresponding to these transitions is sensitive to the density in the range of 1016-1020 cm-3 while the temperature ranges from 10 to 100 eV for ions with nuclear charge Zn ∼ 10. Calculations were carried out for F VIII ion and allowed to determine parameters of plasma jets created by nanosecond laser system ELFIE (Ecole Polytechnique, France) for astrophysical phenomenon modelling. Obtained dependencies are quite universal and can be used for any recombining plasma containing He-like fluorine ions.

  6. LIF-imaging and gas-phase diagnostics of laser desorbed MALDI-matrix plumes

    Energy Technology Data Exchange (ETDEWEB)

    Puretzky, A.A.; Geohegan, D.B. [Oak Ridge National Lab., TN (United States). Solid State Div.

    1997-07-01

    The first gated LIF-imaging and absorption spectroscopy has been performed on laser desorbed plumes from organic crystals which are commonly used as MALDI (Matrix Assisted Laser Desorption Ionization) matrices. These plasma diagnostic techniques, including ion probe measurements were employed to investigate the desorbed products, densities, fractional ionization, and velocity distributions of the plume of ejecta which is typically employed as the main desorption product in the mass spectrometry analysis of large biomolecules. Ultraviolet pulsed 193-nm and 248-nm irradiation of 3-hydroxypicolinic acid (3-HPA) crystals were studied to understand the effect of very different gas-phase absorption cross sections measured here for this material. In both cases, LIF imaging revealed two plume components: a fast (maximum {approximately} 0.1 cm/{micro}s) low-intensity component which appear to be 3-HPA fragments, and a slower component of 3-HPA expanding at 0.05 cm/{micro}s. In the case of ArF-laser irradiation, optical absorption spectroscopy indicated a breaking of the intramolecular hydrogen bond in the gas-phase matrix material.

  7. A methodology for laser diagnostics in large-bore marine two-stroke diesel engines

    Science.gov (United States)

    Hult, J.; Mayer, S.

    2013-04-01

    Large two-stroke diesel engines for marine propulsion offer several challenges to successful implementation of the laser diagnostic techniques applied extensively in smaller automotive engines. For this purpose a fully operational large-bore engine has been modified to allow flexible optical access, through 24 optical ports with clear diameters of 40 mm. By mounting the entire optical set-up directly to the engine, effects of the vigorous vibrations and thermal drifts on alignment can be minimized. Wide-angle observation and illumination, as well as relatively large aperture detection, is made possible through mounting of optical modules and relays inside optical ports. This allows positioning of the last optical element within 10 mm from the cylinder wall. Finally, the implementation on a multi-cylinder engine allows for flexible and independent operation of the optically accessible cylinder for testing purposes. The performance of the integrated optical engine and imaging system developed is demonstrated through laser Mie scattering imaging of fuel jet structures, from which information on liquid penetration and spray angles can be deduced. Double pulse laser-sheet imaging of native in-cylinder structures is also demonstrated, for the purpose of velocimetry.

  8. Development of the so-called third stage laser Thomson scattering diagnostics of plasmas

    Science.gov (United States)

    Muraoka, Katsunori; Yamagata, Yukihiko; Hisano, Taishi; Uchino, Kiichirou; Miyazaki, Koichi

    2003-10-01

    In the recent review article,^1) we indicated that the incoherent laser Thomson scattering (LTS) diagnostics of plasmas for measurements of electron densities and temperatures (or more generally EEDFs) be classified as having evolved from the first stage where a whole Thomson spectrum be obtained during a single laser pulse from plasmas having electron density of above 10^18 m-3, through the second stage where data accumulation be prerequisite for ne below 10^18 m-3, and to the third stage where a strong suppression of stray light in addition to the data accumulation be necessary to measure at an extremely small size of less than 100 μm near to material surfaces. The third stage LTS was first demonstrated for a PDP (plasma display panel)-like discharge three years ago employing a triple grating polychromator. In order to further expand its applicable ranges, we are pursuing a more general approach by taking into account such factors as laser divergence, stray light suppression and other aspects. The present status is presented. 1) K. Muraoka, K. Uchino, Y. Yamagata, Y. Noguchi, M. Mansour, P. Suanpoot, S. Narishige, and M. Noguchi, Plasma Sources Sci. Technol. 11 (2002) A143.

  9. Depth profilometric case studies in caries diagnostics of human teeth using modulated laser radiometry and luminescence

    Science.gov (United States)

    Jeon, Raymond J.; Mandelis, Andreas; Abrams, Stephen H.

    2003-01-01

    Simultaneous measurements from human teeth of photothermal radiometric (PTR) and luminescence (LM) signals induced by an intensity modulated laser have been performed to assess the feasibility of detecting deep lesions and near-surface cracks, to examine the effects of varying enamel thicknesses, the presence of fillings, and stains on the surface of teeth. A commercial dc luminescence monitoring instrument (DIAGNOdent by KaVo) was also used to examine a set of teeth for comparison purposes with PTR and LM. PTR amplitude signals from carious regions and from thin enamel were higher than those from healthy regions and thicker enamel. A crack produces a peak in the PTR amplitude scan, as well as a sudden change in the luminescence amplitude at the corresponding point. At low frequencies (5 Hz), the PTR amplitude showed high sensitivity to a deep (about 2 mm) lesion, while at high frequencies (700 Hz) it was more sensitive to surface cracks. It was concluded that by selecting proper modulation frequencies of the laser, measurements of PTR and LM signals could be used as a dental diagnostic technique with a small, inexpensive, low-power (<30 mW) semiconductor laser as a light source emitting in the optical window range of hard tissue (650-1000 nm).

  10. Diode Laser Diagnostics for Gas Species and Soot in Large Fires: LDRD Project Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Christopher R. Shaddix; Sarah W. Allendorf; Gary L. Hubbard; David K. Ottesen; Louis A. Gritzo

    2001-06-01

    The thermal hazard posed by a fire to a weapon or other engineered system is a consequence of combined radiation and convection from high-temperature soot and gases. The development of advanced, predictive models of this hazard requires detailed knowledge of the transient chemical structure and soot distributions within real-scale fires. At present, there are no measurements, and hence limited understanding, of transient gaseous species generation and transport in large, fully turbulent fires. As part of a Laboratory Directed Research and Development (LDRD) project to develop such an experimental capability, near-infrared tunable diode laser absorption spectroscopy (TDLAS) has been identified as the most promising diagnostic technique for making these measurements. In order to develop this capability, significant efforts were applied to choosing optimal species and transitions for detection, to developing an effective multiplexing strategy for several lasers undergoing wavelength modulation spectroscopy with fast laser ramp scans, to developing a methodology for multipassing the TDL beams across a small probe volume, and finally, to designing a water-cooled, fiber-coupled probe for performing these measurements locally within large pool fires. All of these challenges were surmounted during the course of this project, and in the end a preliminary, unique dataset of combined water vapor, acetylene, and soot concentrations was obtained from a 1-m diameter JP-8 pool fire.

  11. Nanoscale displacement sensing based on nonlinear frequency mixing in quantum cascade lasers

    CERN Document Server

    Mezzapesa, F P; De Risi, G; Brambilla, M; Dabbicco, M; Spagnolo, V; Scamarcio, G

    2015-01-01

    We demonstrate a sensor scheme for nanoscale target displacement that relies on a single Quantum Cascade Laser (QCL) subject to optical feedback. The system combines the inherent sensitivity of QCLs to optical re-injection and their ultra-stability in the strong feedback regime where nonlinear frequency mixing phenomena are enhanced. An experimental proof of principle in the micrometer wavelength scale is provided. We perform real-time measurements of displacement with {\\lambda}/100 resolution by inserting a fast-shifting reference etalon in the external cavity. The resulting signal dynamics at the QCL terminals shows a stroboscopic-like effect that relates the sensor resolution with the reference etalon speed. Intrinsic limits to the measurement algorithm and to the reference speed are discussed, disclosing that nanoscale ranges are attainable.

  12. High Power Amplifiers Chain nonlinearity influence on the accelerating beam stability in free electron laser (FLASH)

    CERN Document Server

    Cichalewski, w

    2010-01-01

    The high power amplifiers transfer characteristics nonlinearities can have a negative influence on the overall system performance. This is also true for the TESLA superconducting cavities accelerating field parameters control systems. This Low Level Radio Frequency control systems uses microwave high power amplifiers (like 10 MW klystrons) as actuators in the mentioned feedback loops. The amplitude compression and phase deviations phenomena introduced to the control signals can reduce the feedback performance and cause electron beam energy instabilities. The transfer characteristics deviations in the Free Electron Laser in Hamburg experiment have been investigated. The outcome of this study together with the description of the developed linearization method based on the digital predistortion approach have been described in this paper. Additionally, the results from the linearization tool performance tests in the FLASH's RF systems have been placed.

  13. Electronic control of nonlinear-polarization-rotation mode locking in Yb-doped fiber lasers.

    Science.gov (United States)

    Shen, Xuling; Li, Wenxue; Yan, Ming; Zeng, Heping

    2012-08-15

    We demonstrate a convenient approach to precisely tune the polarization state of a nonlinear-polarization-rotation mode-locked Yb-doped fiber laser by using an electronic polarization controller. It is shown to benefit self-starting of mode-locking states, with precise tuning of the spectral profile, pulse width, and carrier-envelope offset frequency. The pulse width changed linearly by 0.78 ps in the time domain, and the carrier-envelope offset frequency shifted ~77.5 MHz in the frequency domain with a slight change of the driving voltage of 30.7 mV applied on the controller, corresponding to a polarization rotation of 0.0135π. This facilitated precise and automatic regeneration of a particular mode-locking state by setting an accurate voltage at the polarization controller with a programmed microprocessor control unit.

  14. Giant optical nonlinearity of silver-doped silicon thin film at low power input: laser-triggered cluster resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Jingsong [Chinese Academy of Sciences, Shanghai Institute of Optics and Fine Mechanics, Shanghai (China); Zhejiang University, State Key Lab of Silicon Materials, Hangzhou (China); Liu, Jing [Chinese Academy of Sciences, Shanghai Institute of Optics and Fine Mechanics, Shanghai (China); Xiao, Mufei [Universidad Nacional Autonoma de Mexico, Centro de Nanociencias y Nanotecnologia, Apartado Postal 365, Ensenada, Baja California (Mexico)

    2011-09-15

    Silver-doped silicon thin films were deposited on glass substrate in a co-sputtering procedure. Silver nanoparticles were segregatedly distributed. The nonlinear properties were extracted by z-scan measurements at low laser input power. For about 50% silver density, the nonlinear absorption and refraction coefficients peaked, respectively, at -8.086 x 10{sup -2} m/W and 1.47 x 10{sup -9} m{sup 2}/W, which, with respect to the input intensity, are several orders higher than reported data. The sudden surge of nonlinear responses was explained satisfactorily based on a self-consistent microscopic model calculation for silver clusters. Resonances exist and depend apparently on the laser-modified local cluster concentration. (orig.)

  15. Linear and nonlinear resonance features of an erbium-doped fibre ring laser under cavity-loss modulation

    Indian Academy of Sciences (India)

    Aditi Ghosh; R Vijaya

    2014-07-01

    The continuous-wave output of a single-mode erbium-doped fibre ring laser when subjected to cavity-loss modulation is found to exhibit linear as well as nonlinear resonances. At sufficiently low driving amplitude, the system resembles a linear damped oscillator. At higher amplitudes, the dynamical study of these resonances shows that the behaviour of the system exhibits features of a nonlinear damped oscillator under harmonic modulation. These nonlinear dynamical features, including harmonic and subharmonic resonances, have been studied experimentally and analysed with the help of a simple time-domain and frequency-domain information obtained from the output of the laser. All the studies are restricted to the modulation frequency lying in a regime near the relaxation oscillation frequency.

  16. Non-linear optical processes involving excited subbands in laser-dressed quantum wires with triangular cross-section

    Science.gov (United States)

    Radu, A.; Duque, C. A.

    2015-08-01

    The conduction subband structure of a triangular cross-section GaAs/AlGaAs quantum well wire under intense laser field is theoretically investigated by taking into account a finite confining potential. The calculation of the subband energy levels is based on a two-dimensional finite element method within the effective mass approximation. It is shown that a transversally polarized laser field non-uniformly shifts the subband energy levels and could be used for tuning the intersubband transitions and altering the related optical susceptibilities. We found that the non-resonant laser field allows the magnification and the red- or blueshift of the third-order non-linear susceptibility peaks for particular polarizations of the pump light and proper laser parameter values. The effects of the laser dressing field on the intersubband third harmonic generation and quadratic electro-optical process are discussed.

  17. Optical Nonlinear Refractive Index of Laser-Ablated Gold Nanoparticles Graphene Oxide Composite

    Directory of Open Access Journals (Sweden)

    Amir Reza Sadrolhosseini

    2014-01-01

    Full Text Available Gold nanoparticles were prepared in graphene oxide using laser ablation technique. The ablation times were varied from 10 to 40 minutes, and the particle size was decreased from 16.55 nm to 5.18 nm in spherical shape. The nanoparticles were capped with carboxyl and the hydroxyl groups were obtained from Fourier transform infrared spectroscopy. Furthermore, the UV-visible peak shifted with decreasing of nanoparticles size, appearing from 528 nm to 510 nm. The Z-scan technique was used to measure the nonlinear refractive indices of graphene oxide with different concentrations and a gold nanoparticle graphene oxide nanocomposite. Consequently, the optical nonlinear refractive indices of graphene oxide and gold nanoparticle graphene oxide nanocomposite were shifted from 1.63×10-9 cm2/W to 4.1×10-9 cm2/W and from 1.85×10-9 cm2/W to 5.8×10-9 cm2/W, respectively.

  18. Theoretical investigation on nonlinear optical effects in laser trapping of dielectric nanoparticles with ultrafast pulsed excitation.

    Science.gov (United States)

    Devi, Anita; De, Arijit K

    2016-09-19

    The use of low-power high-repetition-rate ultrafast pulsed excitation in stable optical trapping of dielectric nanoparticles has been demonstrated in the recent past; the high peak power of each pulse leads to instantaneous trapping of a nanoparticle with fast inertial response and the high repetition-rate ensures repetitive trapping by successive pulses However, with such high peak power pulsed excitation under a tight focusing condition, nonlinear optical effects on trapping efficiency also become significant and cannot be ignored. Thus, in addition to the above mentioned repetitive instantaneous trapping, trapping efficiency under pulsed excitation is also influenced by the optical Kerr effect, which we theoretically investigate here. Using dipole approximation we show that with an increase in laser power the radial component of the trapping potential becomes progressively more stable but the axial component is dramatically modulated due to increased Kerr nonlinearity. We justify that the relevant parameter to quantify the trapping efficiency is not the absolute depth of the highly asymmetric axial trapping potential but the height of the potential barrier along the beam propagation direction. We also discuss the optimal excitation parameters leading to the most stable dipole trap. Our results show excellent agreement with previous experiments.

  19. Etching, micro hardness and laser damage threshold studies of a nonlinear optical material L-valine

    Science.gov (United States)

    Anbuchezhiyan, M.; Ponnusamy, S.; Muthamizhchelvan, C.; Kanakam, C. C.; Singh, S. P.; Pal, P. K.; Datta, P. K.

    2012-04-01

    A nonlinear optical crystal of L-valine was grown from an aqueous solution containing a small amount of phosphoric acid by the slow evaporation method. The grown crystal was characterized by a single crystal X-ray diffraction to determine the unit cell parameters. The powder X-ray diffraction analysis also confirmed the lattice parameters to be a = 9.6687(7) Å, b = 5.2709(4) Å, c = 12.0371(10) Å and β = 90.805(4)°. The results of the Inductively Coupled Plasma Optical Emission Spectrometry (ICPOES) indicate the presence of a small amount of phosphorus in the grown crystal. The Vickers micro hardness test was performed to study the mechanical strength of the crystals. Chemical etching studies were carried out to analyze the dislocation structure. The laser damaged threshold of the grown crystal was measured to be 11.11 GW/cm2 for 10 ns pulse at 1064 nm, which is higher than that of the standard nonlinear optical crystals like KDP. Second harmonic generation of the grown crystals was also 1.44 times that of KDP.

  20. Nonlinear absorption and optical limiting in Duran glass induced by 800 nm femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Jamshidi-Ghaleh, Kazem [Department of Physics, Azerbaijan University of Tarbiat Moallem, Tabriz (Iran, Islamic Republic of); Mansour, Nastaran [Department of Physics, Shahi Beheshti University, Tehran (Iran, Islamic Republic of)

    2007-01-21

    Nonlinear absorption of Duran glass by irradiation of a focused 200 fs pulsed laser were investigated using the z-scan technique at 800 nm. Optical limiting behaviour in this glass has also been measured. The limiting threshold was measured to 33 {mu}J pulse energy (peak intensity of 2.4 x 10{sup 12} W cm{sup -2}) in this sample. The decrease in transmitted intensity is around 75% compared with the theoretical linear transmission for incident pulses pulse energies 320 {mu}J (peak intensity of 5 x 10{sup 12} W cm{sup -2}). A comparison of the theoretical analyses with the experimental results shows that three-photon absorption and three-photon generated free-carrier absorption within the glasses are the main mechanisms for the observed nonlinear response. The values of the three-photon absorption coefficient and the photo-generated free-carrier cross section are measured as {gamma} = 2 x 10{sup -24}cm{sup 3} W{sup -2} and {sigma} = 1.2 x 10{sup -18} cm{sup 2}, respectively.

  1. Non-linear Spectroscopy of Sr Atoms in an Optical Cavity for Laser Stabilization

    CERN Document Server

    Christensen, Bjarke T R; Schäffer, Stefan A; Westergaard, Philip G; Ye, Jun; Holland, Murray; Thomsen, Jan W

    2015-01-01

    We study the non-linear interaction of a cold sample of strontium-88 atoms coupled to a single mode of a low finesse optical cavity in the so-called bad cavity limit and investigate the implications for applications to laser stabilization. The atoms are probed on the weak inter-combination line $\\lvert 5s^{2} \\, ^1 \\textrm{S}_0 \\rangle \\,-\\, \\lvert 5s5p \\, ^3 \\textrm{P}_1 \\rangle$ at 689 nm in a strongly saturated regime. Our measured observables include the atomic induced phase shift and absorption of the light field transmitted through the cavity represented by the complex cavity transmission coefficient. We demonstrate high signal-to-noise-ratio measurements of both quadratures - the cavity transmitted phase and absorption - by employing FM spectroscopy (NICE-OHMS). We also show that when FM spectroscopy is employed in connection with a cavity locked to the probe light, observables are substantially modified compared to the free space situation where no cavity is present. Furthermore, the non-linear dynami...

  2. Diagnostic Values of Laser Fluorescence Device with Other Techniques in Occlusal Caries Detection

    Directory of Open Access Journals (Sweden)

    A. Chehresaz

    2009-06-01

    Full Text Available Objective: The aim of the present study was to compare the performance of laser fluorescence (LF method with other conventional diagnostic techniques in detection of smallocclusal caries in permanent teeth.Materials and Methods: Prior to this in vitro diagnostic study, a pilot study assessed intra-examiner reliability and reproducibility. The occlusal surfaces of 90 extracted human premolars were examined with four diagnostic methods: probing, visual inspection, bitewing(BW radiographs, and LF. The teeth were then sectioned for the purpose of histological examination. The data were analyzed using SPSS 15 software, and sensitivity,specificity and other diagnostic criteria of the techniques were calculated.Results: The intra-examiner reproducibility for probing and also radiographic techniques was 100%. The corresponded figure for LF (88% was more than visual inspection (82%.The highest level of validity of the examiner turned out to be in probing technique(76.9%. Sensitivity of visual inspection, probing, and LF methods was 54.5% and that of BW radiography was 27.5%. Specificity and efficiency of LF method were 84.8% and 81.1%, respectively. Probing and visual inspection showed the highest specificity (97.5% and 94.9, respectively and efficiency (92.2% and 90%, respectively among the methods.Conclusion: Specificity and efficiency of LF method were lower compared to those of other methods. Among all the investigated methods, the most efficient methods in the diagnosis of small occlusal caries in permanent teeth were probing and visual inspection,respectively.

  3. [Meta-analysis on the diagnostic value of laser Doppler imaging for burn depth].

    Science.gov (United States)

    Huang, Y; Qiu, L; Mei, A L; Li, J X

    2017-05-20

    Objective: To evaluate the value of laser Doppler imaging (LDI) in diagnosing deep or superficial partial-thickness burn wound with meta-analysis. Methods: Databases including PubMed, Cochrane Library were searched using key words " burn, burns, burn depth, laser Doppler imaging, laser Doppler perfusion imaging, LDI, LDPI" , and Chinese Journals Full-text Database, Wanfang Database, VIP Database were searched using Chinese key words ",,,," to obtain the published trials of LDI in diagnosing deep or superficial partial-thickness burn wound from the establishment of each database to October 2015. The risk of bias and applicability concerns of the included studies were evaluated by Quality Assessment of Diagnostic Accuracy Studies-2. Data were processed with Meta-DiSc 1.4 statistical software. The heterogeneity among the included studies was evaluated. The pooled estimates of LDI in diagnosing deep or superficial partial-thickness burn wound in the included studies, including sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, as well as the area under the curve of summary receiver operating characteristic and index of Q(*) were calculated. The stability of results of the overall pooled estimates of the included studies was validated by sensitivity analysis. The sources of heterogeneity among the included studies were sought through subgroup analysis. The publication bias caused by the results of the included studies was evaluated by drawing the Deek's funnel plot. Results: A total of 5 articles conforming to the inclusion criteria, involving 138 patients and 179 burn wounds, were included. One of the included studies had low risk of bias, while the other 4 studies had high/unclear risk of bias. In applicability concern aspect, one of the included studies had high/unclear concerns regarding applicability, while the other 4 studies had low concerns regarding applicability. There was no heterogeneity caused by threshold

  4. Characterization and diagnostics of combustion thermoacoustic instabilities using nonlinear dynamics and topological methods

    CERN Document Server

    Gianni, G; Paganini, E; Sello, S

    2003-01-01

    The onset of thermoacoustic instabilities in lean-premixed gas-turbine combustors is a crucial problem leading to degradation in engine and emissions performance and shortened component life. The main aim of this study is to propose a methodology based both on concepts of nonlinear dynamics and on geometric-topological invariants, for the characterization of attractors related to measurements based on the flame spontaneous light emission, like OH* radical, in order to classify different phases of the combustion process and to better recognize the transition mechanisms leading to the thermoacoustic instabilities. Preliminary results, clearly show the powerfulness of the approach to show the dynamical evolution of the flame and to evidence the onset of the thermoacoustic instabilities: in particular the topological invariant index (genus and related quantities) appear s as the best candidate for an early indicator of the dynamical transition, characterized by the onset of a more persistent, low entropy torus (q...

  5. Sub-nanosecond optical diagnostics of laser-material interaction and dynamic microstructure of materials

    Energy Technology Data Exchange (ETDEWEB)

    Paisley, D.L.; Stahl, D.B.

    1993-03-01

    Several optical diagnostic techniques are used to evaluate the dynamic response of materials to intense dynamic loading and unloading, high stress and strain, and pressure. Velocity interferometry and electronic streak photography, each with sub-nanosecond time resolution, are used to record dynamic material response. Laser-launched flat plates are accelerated to 10{sup 12} m/s{sup 2} with terminal velocities >5 km/s. By impacting these plates into target samples, high strain rates (10{sup 8} sec{sup {minus}1}) and pressures >100 GPa have been generated for a duration of 0.8--5 nanoseconds. The efficacy and limitations of each technique are detailed and applications to other fields discussed.

  6. Sub-nanosecond optical diagnostics of laser-material interaction and dynamic microstructure of materials

    Energy Technology Data Exchange (ETDEWEB)

    Paisley, D.L.; Stahl, D.B.

    1993-01-01

    Several optical diagnostic techniques are used to evaluate the dynamic response of materials to intense dynamic loading and unloading, high stress and strain, and pressure. Velocity interferometry and electronic streak photography, each with sub-nanosecond time resolution, are used to record dynamic material response. Laser-launched flat plates are accelerated to 10[sup 12] m/s[sup 2] with terminal velocities >5 km/s. By impacting these plates into target samples, high strain rates (10[sup 8] sec[sup [minus]1]) and pressures >100 GPa have been generated for a duration of 0.8--5 nanoseconds. The efficacy and limitations of each technique are detailed and applications to other fields discussed.

  7. Fast phosphor picosecond streak tube for ultrafast laser diagnostics in repetitive mode

    Science.gov (United States)

    Ageeva, N. V.; Gornostaev, P. B.; Ivanova, S. R.; Kulechenkova, T. P.; Levina, G. P.; Lozovoi, V. I.; Makushina, V. A.; Schelev, M. Ya; Shashkov, E. V.; Scaballanovich, T. A.; Smirnov, A. V.; Vereschagin, A. K.; Vereschagin, K. A.; Vorobiev, N. S.

    2015-08-01

    The well-established PIF-01/S1/P43 picosecond streak tube, designed 30 years ago and still manufactured at the A.M. Prokhorov General Physics Institute, was modified by replacing its traditional P43 phosphor screen with a P47 one having approximately three orders of magnitude shorter decay time. The experimental measurements of this decay time were provided by PIF-01/S1/P47 image tube photocathode irradiation either with a single or a train of 8 ps laser pulses separated by 8 ns from each other at a 1.08 μm wavelength. The results of our preliminary measurements of P47-BH phosphor (manufactured by Phosphor Technology Ltd) indicate the possibility of employing the PIF-01/S1/P47 streak tube for synchrotron diagnostics at a units megahertz repetition rate without the negative influence of ‘ghost images’ from the previous streak records.

  8. [Confocal Laser Endomicroscopy in the Diagnostics of Malignancy of the Gastrointestinal Tract].

    Science.gov (United States)

    Moravčík, P; Hlavsa, J; Kunovsky, L; Kala, Z; Penka, I; Dastych, M

    2017-01-01

    In confocal laser endomicroscopy (CLE), a type of optical microscope that uses a laser beam as its light source and processes the acquired image by processor unit is used. Although the principle behind the device has been known since 1957, its use in clinical practice has only recently been enabled by technical developments, and it is therefore a relatively new modality in differential diagnosis. CLE enables real-time microscopic imaging of the tissue under investigation and in fact non-invasive in vivo biopsy. First experiences with CLE have primarily been obtained in the field of endoscopy, in particular in the pathology of the esophagus, stomach, bile duct, pancreas, and colon. Further to its use in endoscopy, CLE was recently developed for perioperative use, with the most experience gained in neurological, breast, and prostate surgery. Numerous prospective randomized trials have confirmed the benefits of CLE in tumor screening, differential diagnosis of tumors or inflammatory diseases, earlier diagnostics of diseases, and reducing the number of required endoscopic examinations. In addition, CLE is associated with minimal side effects. A known possible side effect is allergy to the fluorescein used to stain tissues during the examination. Extending of endoscopic examination or surgery is minimal in the hands of trained personnel. Current limiting factors of CLE include insufficient clinical experience, the price of the CLE device and probes, and the subjectivity inherent in the evaluation of microscopic images by the endoscopist or surgeon. This article summarizes published studies of CLE in the diagnostics of oncological diseases of the gastrointestinal tract.Key words: confocal microscopy - gastrointestinal tract - neoplasms The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study. The Editorial Board declares that the manuscript met the ICMJE recommendation for biomedical papers.Submitted: 9. 2

  9. RESEARCH OF LINEAR AND NONLINEAR PROCESSES AT FEMTOSECOND LASER RADIATION PROPAGATION IN THE MEDIUM SIMULATING THE HUMAN EYE VITREOUS

    Directory of Open Access Journals (Sweden)

    P. Y. Rogov

    2015-09-01

    Full Text Available The paper deals with mathematical model of linear and nonlinear processes occurring at the propagation of femtosecond laser pulses in the vitreous of the human eye. Methods of computing modeling are applied for the nonlinear spectral equation solution describing the dynamics of a two-dimensional TE-polarized radiation in a homogeneous isotropic medium with cubic fast-response nonlinearity without the usage of slowly varying envelope approximation. Environments close to the optical media parameters of the eye were used for the simulation. The model of femtosecond radiation propagation takes into account the process dynamics for dispersion broadening of pulses in time and the occurence of the self-focusing near the retina when passing through the vitreous body of the eye. Dependence between the pulse duration on the retina has been revealed and the duration of the input pulse and the values of power density at which there is self-focusing have been found. It is shown that the main mechanism of radiation damage with the use of titanium-sapphire laser is photoionization. The results coincide with those obtained by the other scientists, and are usable for creation Russian laser safety standards for femtosecond laser systems.

  10. Feasibility study for electron beam and laser Raman non-intrusive diagnostic measurements in hypersonic blowdown wind tunnels

    Science.gov (United States)

    Powell, Homer M.; Ventrice, Carl A.; Yanta, William; Hedlund, Eric; Moyers, Richard L.

    Calculations based upon density measurements are presented for assessing the feasibility of electron beam and laser Raman flow diagnostic techniques for hypersonic blowdown wind tunnels of the Naval-Surface-Weapons-Center class. It is concluded that the electron beam technique is applicable only for flow visualization purposes, even at the low end of the test envelope.

  11. The diagnostic capability of laser induced fluorescence in the characterization of excised breast tissues

    Science.gov (United States)

    Galmed, A. H.; Elshemey, Wael M.

    2017-08-01

    Differentiating between normal, benign and malignant excised breast tissues is one of the major worldwide challenges that need a quantitative, fast and reliable technique in order to avoid personal errors in diagnosis. Laser induced fluorescence (LIF) is a promising technique that has been applied for the characterization of biological tissues including breast tissue. Unfortunately, only few studies have adopted a quantitative approach that can be directly applied for breast tissue characterization. This work provides a quantitative means for such characterization via introduction of several LIF characterization parameters and determining the diagnostic accuracy of each parameter in the differentiation between normal, benign and malignant excised breast tissues. Extensive analysis on 41 lyophilized breast samples using scatter diagrams, cut-off values, diagnostic indices and receiver operating characteristic (ROC) curves, shows that some spectral parameters (peak height and area under the peak) are superior for characterization of normal, benign and malignant breast tissues with high sensitivity (up to 0.91), specificity (up to 0.91) and accuracy ranking (highly accurate).

  12. Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

    Science.gov (United States)

    Grinstead, Jay H.; Wilder, Michael C.; Porter, Barry J.; Brown, Jeffrey D.; Yeung, Dickson; Battazzo, Stephen J.; Brubaker, Timothy R.

    2016-01-01

    The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (LIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper will document the latest improvements of the LIF system design and demonstrations of the redeveloped AHF and IHF LIF systems.

  13. Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

    Science.gov (United States)

    Grinstead, Jay; Wilder, Michael C.; Porter, Barry; Brown, Jeff; Yeung, Dickson; Battazzo, Steve; Brubaker, Tim

    2016-01-01

    The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnsons arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.

  14. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry

    Science.gov (United States)

    Serafini, S.; Paone, N.; Castellini, P.

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  15. Quality control agent: Self-adaptive laser vibrometry for on-line diagnostics

    Science.gov (United States)

    Serafini, S.; Paone, N.; Castellini, P.

    2012-06-01

    It is presented the development of a self-adaptive diagnostic system based on laser vibrometry for production line quality control. The vibration measurement system consists of a laser Doppler vibrometer, equipped with scanning mirrors and a smart camera, which implements self-adaptivity for compensating target mis-positioning under guidance by a vision system and for the achievement of the best condition for measurement by optimizing the Doppler signal level. This system is designed as a Quality Control Agent (QCA) and it is part of a Multi Agent System (MAS) that supervises all the production line. The QCA behavior is defined so to perform a minimization of measurement uncertainty during the on line tests; for this purpose the QCA exhibits a self-adaptive behavior. Best measurement conditions are defined in terms of amplitude of the optical Doppler beat signal (signal quality - SQ). In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed.

  16. Therapeutic and diagnostic set for irradiation the cell lines in low level laser therapy

    Science.gov (United States)

    Gryko, Lukasz; Zajac, Andrzej; Gilewski, Marian; Szymanska, Justyna; Goralczyk, Krzysztof

    2014-05-01

    In the paper is presented optoelectronic diagnostic set for standardization the biostimulation procedures performed on cell lines. The basic functional components of the therapeutic set are two digitally controlled illuminators. They are composed of the sets of semiconductor emitters - medium power laser diodes and high power LEDs emitting radiation in wide spectral range from 600 nm to 1000 nm. Emitters are coupled with applicator by fibre optic and optical systems that provides uniform irradiation of vessel with cell culture samples. Integrated spectrometer and optical power meter allow to control the energy and spectral parameters of electromagnetic radiation during the Low Level Light Therapy procedure. Dedicated power supplies and digital controlling system allow independent power of each emitter . It was developed active temperature stabilization system to thermal adjust spectral line of emitted radiation to more efficient association with absorption spectra of biological acceptors. Using the set to controlled irradiation and allowing to measure absorption spectrum of biological medium it is possible to carry out objective assessment the impact of the exposure parameters on the state cells subjected to Low Level Light Therapy. That procedure allows comparing the biological response of cell lines after irradiation with radiation of variable spectral and energetic parameters. Researches were carried out on vascular endothelial cell lines. Cells proliferations after irradiation of LEDs: 645 nm, 680 nm, 740 nm, 780 nm, 830 nm, 870 nm, 890 nm, 970 nm and lasers 650 nm and 830 nm were examined.

  17. Integrated analysis of millisecond laser irradiation of steel by comprehensive optical diagnostics and numerical simulation

    Science.gov (United States)

    Doubenskaia, M.; Smurov, I.; Nagulin, K. Yu.

    2016-04-01

    Complimentary optical diagnostic tools are applied to provide comprehensive analysis of thermal phenomena in millisecond Nd:YAG laser irradiation of steel substrates. The following optical devices are employed: (a) infrared camera FLIR Phoenix RDASTM equipped by InSb sensor with 3 to 5 µm band pass arranged on 320 × 256 pixels array, (b) ultra-rapid camera Phantom V7.1 with SR-CMOS monochrome sensor in the visible spectral range, up to 105 frames per second for 64 × 88 pixels array, (c) original multi-wavelength pyrometer in the near-infrared range (1.370-1.531 µm). The following laser radiation parameters are applied: variation of energy per pulse in the range 15-30 J at a constant pulse duration of 10 ms with and without application of protective gas (Ar). The evolution of true temperature is restored based on the method of multi-colour pyrometry; by this way, melting/solidification dynamics is analysed. Emissivity variation with temperature is studied, and hysteresis type functional dependence is found. Variation of intensity of surface evaporation visualised by the camera Phantom V7.1 is registered and linked with the surface temperature evolution, different surface roughness and influence of protective gas atmosphere. Determination of the vapour plume temperature based on relatively intensities of spectral lines is done. The numerical simulation is carried out applying the thermal model with phase transitions taken into account.

  18. Innovative single-shot diagnostics for electrons from laser wakefield acceleration at FLAME

    Science.gov (United States)

    Bisesto, F. G.; Anania, M. P.; Cianchi, A.; Chiadroni, E.; Curcio, A.; Ferrario, M.; Pompili, R.; Zigler, A.

    2017-07-01

    Plasma wakefield acceleration is the most promising acceleration technique known nowadays, able to provide very high accelerating fields (> 100 GV/m), enabling acceleration of electrons to GeV energy in few centimeters. Here we present all the plasma related activities currently underway at SPARC_LAB exploiting the high power laser FLAME. In particular, we will give an overview of the single shot diagnostics employed: Electro Optic Sampling (EOS) for temporal measurement and Optical Transition Radiation (OTR) for an innovative one shot emittance measurements. In detail, the EOS technique has been employed to measure for the first time the longitudinal profile of electric field of fast electrons escaping from a solid target, driving the ions and protons acceleration, and to study the impact of using different target shapes. Moreover, a novel scheme for one shot emittance measurements based on OTR, developed and tested at SPARC_LAB LINAC, used in an experiment on electrons from laser wakefield acceleration still undergoing, will be shown.

  19. PREFACE: Fourteenth International Symposium on Laser-Aided Plasma Diagnostics (LAPD14)

    Science.gov (United States)

    Giudicotti, L.; Pasqualotto, R.

    2010-04-01

    The attached PDF contains, the full preface, a list of the scientific committee, former LAPD chairmen, local organizers, previous locations of LAPD meetings, participants email contacts and a list of the contributed papers. logo The Fourteenth International Symposium on Laser-Aided Plasma Diagnostics (LAPD14), was held from 21-24 September 2009 in Castelbrando, Treviso, Italy. The series of LAPD symposia was originally started at Kyushu University in 1983, and since then it has been organized every two years alternately in Japan, Europe and the United States, traveling around the world five times. Each LAPD Symposium brings together scientists working in different disciplines all related to the diagnostics of any type of plasma by laser or similar techniques. Researchers working on nuclear fusion, industrial process, low temperature plasma chemistry, laser development and material science, are invited to present prominent new diagnostic developments, with the aim of synergetic discussions. The broad spectrum of contributions represents one of the strengths of this symposium, which is an important, unique and fruitful source of cross-fertilization between these fields and a forum of discussions. The scope of LAPD14 was very broad, including many techniques related to laser probing of plasmas: incoherent and coherent Thomson scattering, polarimetry, interferometry, reflectometry, laser induced fluorescence, laser absorption spectroscopy, laser photodetachment spectroscopy, cavity ringdown spectroscopy, Raman scattering, reflectometry, microwave diagnostics and related laser and hardware developments. LAPD14 was attended by 66 researchers, from 15 different countries who presented a total of 57 papers (13 general, 12 topical, 10 short talks and 23 poster contributions). It is a tradition of LAPD that the first lecture of each meeting, which is more general and aims to review prominent new developments, is called 'the Akazaki lecture' in honor of Professor Masanori

  20. Imaging of normal and pathologic joint synovium using nonlinear optical microscopy as a potential diagnostic tool

    Science.gov (United States)

    Tiwari, Nivedan; Chabra, Sanjay; Mehdi, Sheherbano; Sweet, Paula; Krasieva, Tatiana B.; Pool, Roy; Andrews, Brian; Peavy, George M.

    2010-09-01

    An estimated 1.3 million people in the United States suffer from rheumatoid arthritis (RA). RA causes profound changes in the synovial membrane of joints, and without early diagnosis and intervention, progresses to permanent alterations in joint structure and function. The purpose of this study is to determine if nonlinear optical microscopy (NLOM) can utilize the natural intrinsic fluorescence properties of tissue to generate images that would allow visualization of the structural and cellular composition of fresh, unfixed normal and pathologic synovial tissue. NLOM is performed on rabbit knee joint synovial samples using 730- and 800-nm excitation wavelengths. Less than 30 mW of excitation power delivered with a 40×, 0.8-NA water immersion objective is sufficient for the visualization of synovial structures to a maximum depth of 70 μm without tissue damage. NLOM imaging of normal and pathologic synovial tissue reveals the cellular structure, synoviocytes, adipocytes, collagen, vascular structures, and differential characteristics of inflammatory infiltrates without requiring tissue processing or staining. Further study to evaluate the ability of NLOM to assess the characteristics of pathologic synovial tissue and its potential role for the management of disease is warranted.

  1. Photon undulatory non-linear conversion diagnostic method for caries detection: a pilot study.

    Science.gov (United States)

    Kesler, G; Masychev, V; Sokolovsky, A; Alexandrov, M; Kesler, A; Koren, R

    2003-08-01

    The objective of this study was to evaluate a new optical method - photon undulatory non-linear conversion (PNC)--for use in different stages of caries detection. Caries should be considered an infectious disease managed by risk assessment, early detection, and preventive therapies, rather than simply "drilling and filling." Fluorescence emission spectroscopy was performed in vitro on 90 extracted teeth, with intact occlusal surfaces. This system differs from the basic Diagnodent unit in its ability to distinguish between different tissue components with respect to their spectrums. Histological analysis served as the gold standard for verification. The teeth sections correspond to the specific point with the highest reading of the detector. The system was compared to visual inspection, probing, and x-ray methods. The system tested (helium-neon [He-Ne], lambda = 633 nm) has a fiber optic device that delivers radiation to the tooth and a spectrophotometer device that detects bacterial porphyrins fluorescence, allowing detection of caries, fillings, and calculus by simultaneous measurement of backscattering and fluorescence intensity. The system tested provides quantitatively reproducible measurements and detection even through sound enamel of more than 1 mm in thickness. The PNC method detects different stages of caries lesions in real time, and it exceeds x-rays in sensitivity, without any ionizing radiation. Preliminary results showed a high potential of using the PNC method in clinical practice (98% accuracy) in comparison to the other methods.

  2. Uncertainty of diagnostic features measured by laser vibrometry: The case of optically non-cooperative surfaces

    Science.gov (United States)

    Agostinelli, G.; Paone, N.

    2012-12-01

    This paper discusses the uncertainty in the measurement of characteristic features by laser Doppler vibrometry useful to industrial diagnostics when measuring on polished, highly reflective, low diffusive surfaces, such as the enamelled metal sheet of the cabinet of electrical household appliances. This case is relevant to on-line quality control applications, where it is not possible to adopt any surface treatment to improve optical scattering properties. The paper illustrates in particular the effect of drop-out noise on the measured vibration signal and develops a joint analysis of drop-out noise due to poor optical properties and its effect on the diagnostic process, presented in statistical terms. A non-dimensional quantity is introduced to describe the amplitude of the Doppler signal and the presence of drop-out noise is shown to be correlated to its amplitude. Starting from the consideration that drop-out noise is impulsive, with a pseudo-random occurrence, this paper presents an experimental assessment of uncertainty in the measurement of some spectral features used for the diagnosis of electrical appliances on the production line. It can be seen that the effect of drop-out leads to an increase in scatter and to a systematic shift in the distribution of the features examined; this effect is relatively larger for features with low amplitude. The Monte Carlo simulation of measurement uncertainty propagation confirms the same trend and allows statistical distributions to be obtained for the features, thereby enabling us to draw some conclusions as regards diagnostic errors. This study shows that in the presence of pseudo-random drop-out noise a diagnosis based on spectral features with low amplitude has poor reliability and false-positives are highly probable. An analysis of this occurrence is made for cases of production exhibiting features with different statistical distributions and possible actions to limit such problem are highlighted.

  3. Advanced beam dynamics and diagnostics concepts for laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Dornmair, Irene

    2017-05-15

    Laser-Plasma Accelerators (LPAs) combine a multitude of unique features, which makes them very attractive as drivers for next generation brilliant light sources including compact X-ray free-electron lasers. They provide high accelerating gradients, thereby drastically shrinking the accelerator size, while at the same time the produced electron bunches are intrinsically as short as a few femtoseconds and carry high peak currents. LPA are subject of very active research, yet, the field currently faces the challenge of improving the beam quality, and achieving stable and well-controlled injection and acceleration. This thesis tackles this issue from three different sides. A novellongitudinal phase space diagnostics is proposed that employs the strong fields present in plasma wakefields to streak ultrashort electron bunches. This allows for a temporal resolution down to the attosecond range, enabling direct determination to the current profile and the slice energy spread, both crucial quantities for the performance of free-electron lasers. Furthermore, adiabatic matching sections at the plasma-vacuum boundary are investigated. These can drastically reduce the beam divergence and thereby relax the constraints on the subsequent beam optics. For externally injected beams, the matching sections could even provide the key technology that permits emittance conservation by increasing the matched beam size to a level achievable with currently available magnetic optics. Finally, a new method is studied that allows to modify the wakefield shape. To this end, the plasma density is periodically modulated. One possible application can be to remove the linearly correlated energy spread, or chirp, from the accelerated bunch, which is suspected of being responsible for the main part of the often large energy spread of plasma accelerated beams.

  4. Confocal laser scanning microscopy, a new in vivo diagnostic tool for schistosomiasis.

    Directory of Open Access Journals (Sweden)

    Carlos Fritzsche

    Full Text Available BACKGROUND: The gold standard for the diagnosis of schistosomiasis is the detection of the parasite's characteristic eggs in urine, stool, or rectal and bladder biopsy specimens. Direct detection of eggs is difficult and not always possible in patients with low egg-shedding rates. Confocal laser scanning microscopy (CLSM permits non-invasive cell imaging in vivo and is an established way of obtaining high-resolution images and 3-dimensional reconstructions. Recently, CLSM was shown to be a suitable method to visualize Schistosoma mansoni eggs within the mucosa of dissected mouse gut. In this case, we evaluated the suitability of CLSM to detect eggs of Schistosoma haematobium in a patient with urinary schistosomiasis and low egg-shedding rates. METHODOLOGY/PRINCIPAL FINDINGS: The confocal laser scanning microscope used in this study was based on a scanning laser system for imaging the retina of a living eye, the Heidelberg Retina Tomograph II, in combination with a lens system (image modality. Standard light cystoscopy was performed using a rigid cystoscope under general anaesthesia. The CLSM endoscope was then passed through the working channel of the rigid cystoscope. The mucosal tissue of the bladder was scanned using CLSM. Schistoma haematobium eggs appeared as bright structures, with the characteristic egg shape and typical terminal spine. CONCLUSION/SIGNIFICANCE: We were able to detect schistosomal eggs in the urothelium of a patient with urinary schistosomiasis. Thus, CLSM may be a suitable tool for the diagnosis of schistosomiasis in humans, especially in cases where standard diagnostic tools are not suitable.

  5. Application of mid-infrared tuneable diode laser absorption spectroscopy to plasma diagnostics: a review

    Energy Technology Data Exchange (ETDEWEB)

    Roepcke, J [INP-Greifswald, 17489 Greifswald, Friedrich-Ludwig-Jahn-Str. 19 (Germany); Lombardi, G [CNRS LIMHP, Universite Paris XIII, 99, av. J.B. Clement, 93430 Villetaneuse (France); Rousseau, A [Laboratoire de Physique et Technologie des Plasmas, Ecole Polytechnique, CNRS, 91128 Palaiseau (France); Davies, P B [Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW (United Kingdom)

    2006-11-01

    Within the last decade mid-infrared absorption spectroscopy over a region from 3 to 17{mu}m and based on tuneable lead salt diode lasers, often called tuneable diode laser absorption spectroscopy or TDLAS, has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry in molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has led to further applications of TDLAS because most of these compounds and their decomposition products are infrared active. TDLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetic phenomena. Information about gas temperature and population densities can also be derived from TDLAS measurements. A variety of free radicals and molecular ions have been detected by TDLAS. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of quantum cascade lasers (QCLs) offers an attractive new option for the monitoring and control of industrial plasma processes. The aim of the present paper is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid-infrared.

  6. Radiation-reaction-force-induced nonlinear mixing of Raman sidebands of an ultraintense laser pulse in a plasma.

    Science.gov (United States)

    Kumar, Naveen; Hatsagortsyan, Karen Z; Keitel, Christoph H

    2013-09-06

    Stimulated Raman scattering of an ultraintense laser pulse in plasmas is studied by perturbatively including the leading order term of the Landau-Lifshitz radiation reaction force in the equation of motion for plasma electrons. In this approximation, the radiation reaction force causes a phase shift in nonlinear current densities that drive the two Raman sidebands (anti-Stokes and Stokes waves), manifesting itself into the nonlinear mixing of two sidebands. This mixing results in a strong enhancement in the growth of the forward Raman scattering instability.

  7. Generation of 3.5 W of diffraction-limited green light from SHG of a single tapered diode laser in a cascade of nonlinear crystals

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh; Jensen, Ole Bjarlin; Sumpf, Bernd;

    2014-01-01

    Many applications, e.g., within biomedicine stand to benefit greatly from the development of diode laser-based multi- Watt efficient compact green laser sources. The low power of existing diode lasers in the green area (about 100 mW) means that the most promising approach remains nonlinear......, such as optical coherence tomography or multimodal imaging devices, e.g., FTCARS-OCT, based on a strongly pumped ultrafast Ti:Sapphire laser....

  8. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Foley, E. L.; Levinton, F. M. [Nova Photonics, Inc., Princeton, New Jersey 08540 (United States)

    2013-04-15

    The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

  9. Automated mode locking in nonlinear polarization rotation fiber lasers by detection of a discontinuous jump in the polarization state.

    Science.gov (United States)

    Olivier, Michel; Gagnon, Marc-Daniel; Piché, Michel

    2015-03-09

    A strategy to align a mode-locked fiber laser with nonlinear polarization rotation is presented. This strategy is based on measurements of the output polarization state. It is shown that, as the angle of a motorized polarization controller inside the cavity is swept, the laser eventually reaches a mode-locked regime and the values of the Stokes parameters undergo an abrupt change. The sensing of this sudden variation is thus used to detect the mode-locking condition and a feedback mechanism drives the alignment of the polarization controller to force mode locking.

  10. Femtosecond-Laser-Inscribed BiB3O6 Nonlinear Cladding Waveguide for Second-Harmonic Generation

    Science.gov (United States)

    Jia, Yuechen; Vázquez de Aldana, Javier R.; Romero, Carolina; Ren, Yingying; Lu, Qingming; Chen, Feng

    2012-07-01

    We report on the fabrication of a nonlinear cladding waveguide in BiB3O6 crystal by using femtosecond laser inscription. The waveguide (with a nearly circular cross section of 150 µm diameter) shows good guiding properties in two transverse polarizations. The guided-wave second-harmonic generation (SHG) at 532 nm green light has been realized under CW and pulsed wave pump at 1064 nm, based on the Type I birefringent phase matching configuration. The conversion efficiencies for CW and pulsed green laser SHG are 0.083 and 25%, respectively.

  11. Dual-wavelength dissipative soliton operation of an erbium-doped fibre laser using a nonlinear polarization rotation technique

    Institute of Scientific and Technical Information of China (English)

    Cao Wen-Jun; Xu Wen-Cheng; Luo Zhi-Chao; Wang Lu-Yan; Wang Hui-Yi; Dong Jiang-Li; Luo Ai-Ping

    2011-01-01

    We report on the generation of dual-wavelength dissipative solitons in a passively mode-locked fibre laser with a net normal dispersion using the nonlinear polarization rotation (NPR) technique.Taking the intrinsic advantage of the intracavity birefringence-induced spectral filtering effect in the NPR-based ring laser cavity,the dual-wavelength dissipative solitons are obtained.In addition,the wavelength separation and the lasing location of the dual-wavelength solitons can be flexibly tuned by changing the orientation of the polarization controller.

  12. Effects of electromagnetic fields on the nonlinear optical properties of asymmetric double quantum well under intense laser field

    Science.gov (United States)

    Yesilgul, U.; Sari, H.; Ungan, F.; Martínez-Orozco, J. C.; Restrepo, R. L.; Mora-Ramos, M. E.; Duque, C. A.; Sökmen, I.

    2017-03-01

    In this study, the effects of electric and magnetic fields on the optical rectification and second and third harmonic generation in asymmetric double quantum well under the intense non-resonant laser field is theoretically investigated. We calculate the optical rectification and second and third harmonic generation within the compact density-matrix approach. The theoretical findings show that the influence of electric, magnetic, and intense laser fields leads to significant changes in the coefficients of nonlinear optical rectification, second and third harmonic generation.

  13. Evaluation of probe lasers employed in optical diagnostics for phase transformation of thin films during excimer laser crystallization

    Science.gov (United States)

    Kuo, Chil-Chyuan

    2008-06-01

    The stability and reliability of probe laser is an important factor affecting the inspection of the phase transformation process of Si thin films during excimer laser crystallization using in-situ time-resolved optical measurements. The changes in 2D intensity profile, peak power density, and beam wander of the commonly used helium-neon (He-Ne) and diode laser are investigated experimentally. It is found that the peak power density of He-Ne laser is higher than that of diode laser, while the total power of He-Ne laser is lower than that of diode laser. Although the instability in the peak power density of He-Ne laser will increase with increasing the operation time, the beam stability of He-Ne laser is better than that of diode laser. For long-time operation (>24 h) of optical measurements, the diode laser is a good candidate of probe laser. Conversely, the diode laser is suitable for the short-time operation (<24 h) of optical measurements because the beam-wander is higher than that of He-Ne laser.

  14. Large third-order optical nonlinearities in iron oxide thin films synthesized by reactive pulsed laser deposition

    Science.gov (United States)

    Mulenko, S. A.; Rudenko, V. I.; Liakhovetskyi, V. R.; Brodin, A. M.; Stefan, N.

    2016-10-01

    We report on a study of the third-order nonlinear optical properties of Fe2O3 thin films, grown by the method of laser deposition on silica (SiO2) substrates. The films were synthesized on substrates at different temperatures (293 K and 800 K) and under different oxygen pressures (0.1 Pa, 0.5 Pa, 1.0 Pa). The resulting films were amorphous, if grown on cold substrates (293 K), or polycrystalline otherwise. The third-order optical susceptibility χ(3) of the films was determined by the Z-scan method at the wavelengths of 1064 nm and 532 nm and the laser pulse width of 20 ns. Remarkably high χ(3) values on the order of 10-4 esu at 1064 nm are obtained. The results show that Fe2O3 thin films are promising nonlinear materials for contemporary optoelectronics.

  15. Calculation of the nonlinear relativistic Thomson scattering fields and Its application to electron distribution function diagnostic

    Science.gov (United States)

    Guasp, J.; Pastor, I.; Álvarez-Estrada, R. F.; Castejón, F.

    2015-02-01

    Analytical results obtained recently of the ab-initio classical incoherent Thomson Scattering (TS) spectrum from a single-electron (Alvarez-Estrada et al 2012 Phys. Plasmas 19 062302) have been numerically implemented in a paralelized code to efficiently compute the TS emission from a given electron distribution function, irrespective of its characteristics and/or the intensity of the incoming radiation. These analytical results display certain differences, when compared with other authors, in the general case of incoming linearly and circularly polarized radiation and electrons with arbitrary initial directions. We regard such discrepancies and the ubiquitous interest in TS as motivations for this work. Here, we implement some analytical advances (like generalized Bessel functions for incoming linearly polarized radiation) in TS. The bulk of this work reports on the efficient computation of TS spectra (based upon our analytical approach), for an electron population having an essentially arbitrary distribution function and for both incoming linearly and circularly polarized radiation. A detailed comparison between the present approach and a previous Monte Carlo one (Pastor et al 2011 Nuclear Fusion 51 043011), dealing with the ab-initio computation of TS spectra, is reported. Both approaches are shown to fully agree with each other. As key computational improvements, the analytical technique yields a × 30 to × 100 gain in computation time and is a very flexible tool to compute the scattered spectrum and eventually the scattered electromagnetic fields in the time domain. The latter are computed explicitly here for the first time, as far as we know. Scaling laws for the power integrated over frequency versus initial kinetic energy are studied for the case of isotropic and monoenergetic electron distribution functions and their potential application as diagnostic tools for high-energy populations is briefly discussed. Finally, we discuss the application of these

  16. Nonlinear impairment compensation for DFT-S OFDM signal transmission with directly modulated laser and direct detection

    Science.gov (United States)

    Gou, Pengqi; Wang, Kaihui; Qin, Chaoyi; Yu, Jianjun

    2017-03-01

    We experimentally demonstrate a 16-ary quadrature amplitude modulation (16QAM) DFT-spread optical orthogonal frequency division multiplexing (OFDM) transmission system utilizing a cost-effective directly modulated laser (DML) and direct detection. For 20-Gbaud 16QAM-OFDM signal, with the aid of nonlinear equalization (NLE) algorithm, we respectively provide 6.2-dB and 5.2-dB receiver sensitivity improvement under the hard-decision forward-error-correction (HD-FEC) threshold of 3.8×10-3 for the back-to-back (BTB) case and after transmission over 10-km standard single mode fiber (SSMF) case, related to only adopt post-equalization scheme. To our knowledge, this is the first time to use dynamic nonlinear equalizer (NLE) based on the summation of the square of the difference between samples in one IM/DD OFDM system with DML to mitigate nonlinear distortion.

  17. Diagnostic capability of scanning laser polarimetry with and without enhanced corneal compensation and optical coherence tomography.

    Science.gov (United States)

    Benítez-del-Castillo, Javier; Martinez, Antonio; Regi, Teresa

    2011-01-01

    To compare the abilities of the current commercially available versions of scanning laser polarimetry (SLP) and optical coherence tomography (OCT), SLP-variable corneal compensation (VCC), SLP-enhanced corneal compensation (ECC), and high-definition (HD) OCT, in discriminating between healthy eyes and those with early-to-moderate glaucomatous visual field loss. Healthy volunteers and patients with glaucoma who met the eligibility criteria were consecutively enrolled in this prospective, cross-sectional, observational study. Subjects underwent complete eye examination, automated perimetry, SLP-ECC, SLP-VCC, and HD-OCT. Scanning laser polarimetry parameters were recalculated in 90-degree segments (quadrants) in the calculation circle to be compared. Areas under the receiver operating characteristic curve (AUROCs) were calculated for every parameter in order to compare the ability of each imaging modality to differentiate between normal and glaucomatous eyes. Fifty-five normal volunteers (mean age 59.1 years) and 33 patients with glaucoma (mean age 63.8 years) were enrolled. Average visual field mean deviation was -6.69 dB (95% confidence interval -8.07 to -5.31) in the glaucoma group. The largest AUROCs were associated with nerve fiber indicator (0.880 and 0.888) for the SLP-VCC and SLP-ECC, respectively, and with the average thickness in the HD-OCT (0.897). The best performing indices for the SLP-VCC, SLP-ECC, and HD OCT gave similar AUROCs, showing moderate diagnostic accuracy in patients with early to moderate glaucoma. Further studies are needed to evaluate the ability of these technologies to discriminate between normal and glaucomatous eyes.

  18. Development of x-ray and ion diagnostics of plasma obtained with a 10-TW femtosecond laser

    Science.gov (United States)

    Ryć, L.; Dobrzański, L.; Dubecky, F.; Jabłoński, S.; Parys, P.; Słysz, W.; Rosiński, M.

    2016-07-01

    Several x-ray and ion semiconductor detectors have been developed for the diagnostics of femtosecond laser plasma generated by a 10-TW laser which was recently commissioned for operation at the Institute of Plasma Physics and Laser Microfusion, Warsaw. A range of detectors has been employed including a CdTe detector for hard x-rays and four detectors for proton detection. These four are SiC and GaN employing a sandwich structure, an interdigitated M-S-M InP detector and finally a silicon photo-diode equipped with an aluminium filter (to shield against scattered light). The detectors presented are innovative as they are not commonly used for the diagnostic of laser plasma. The details of the internal structures of the detectors are presented. The immunity of the detectors to the noise coming from the laser system and the femtosecond plasma is discussed. Lastly, the possibility for further modifications and improvements are considered and discussed.

  19. CO{sub 2} laser diagnostics for measurements of the plasma density profile and plasma density fluctuations on LHD

    Energy Technology Data Exchange (ETDEWEB)

    Vyacheslavov, L.N. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Tanaka, K.; Kawahata, K. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2001-04-01

    A CO{sub 2} laser based diagnostics complimentary to the existing FIR interferometer is proposed. It combines interferometry for plasma density profile measurement under conditions of large density gradients, and both imaging and scattering techniques for observation of plasma fluctuations. Two-colour interferometer with a slablike probe beam and a single multichannel linear detector array provide observation of plasma density profile and density fluctuations at two locations along the probe beam. Basic characteristics of the diagnostics are considered as well as some effects that include dispersion and are critical for two colour imaging technique. The results of the bench-top experiments with the prototype of the interferometer are presented. (author)

  20. Effects of Higher-Order Relativistic Nonlinearity and Wakefield During a Moderately Intense Laser Pulse Propagation in a Plasma Channel

    Institute of Scientific and Technical Information of China (English)

    LIU Ming-Ping; LIU Bing-Bing; LIU San-Qiu; ZHANG Fu-Yang; LIU Jie

    2013-01-01

    Using a variational approach,the propagation of a moderately intense laser pulse in a parabolic preformed plasma channel is investigated.The effects of higher-order relativistic nonlinearity (HRN) and wakefield are included.The effect of HRN serves as an additional defocusing mechanism and has the same order of magnitude in the spot size as that of the transverse wakefield (TWF).The effect of longitudinal wakefield is much larger than those of HRN and TWF for an intense laser pulse with the pulse length equaling the plasma wavelength.The catastrophic focusing of the laser spot size would be prevented in the present of HRN and then it varies with periodic focusing oscillations.

  1. Tunable multiwavelength erbium-doped fiber laser based on nonlinear optical loop mirror and birefringence fiber filter

    Science.gov (United States)

    Li, Yuan; Quan, Mingran; Tian, Jiajun; Yao, Yong

    2015-05-01

    A tunable multiwavelength erbium-doped fiber laser (MWEDFL) based on nonlinear optical loop mirror (NOLM) and tunable birefringence fiber filter (BFF) is proposed and demonstrated. By combination of intensity-dependent loss modulation induced by NOLM and pump power adjustment, the proposed laser can achieve independent control over the number of lasing lines, without affecting other important characteristics such as channel spacing and peak location. In addition, the laser allows wavelength tuning with both the peak location and the spectral range of lasing lines controllable. Specifically, the peak location of lasing lines can be controlled to scan the whole spectral range between adjacent channels of comb filter by adjusting the BFF. Moreover, the spectral range of lasing lines can be controlled by adjusting NOLM. This tunable MWEDFL may be useful for fiber-optic communication and fiber-optic sensing.

  2. Evolution of Electron Phase Orbits of Multi-photon Nonlinear Compton Scattering in High Power Laser-plasma

    Institute of Scientific and Technical Information of China (English)

    HAO Dong-shan; L(U) Jian

    2005-01-01

    The evolution of the electron phase orbits based on the multi-photon nonlinear Compton scattering with the high power laser-plasma is discussed by using Kroll-Morton-Rosenbluth theory. The random evolution of the un-captured electron phase orbits from periodicity to non-periodicity is found after the energy has been exchanged between the electron and photons. With the increase of the absorbed photon number n by an electron,this evolution will be more and more intense, while which is rapidly decreased with the enhancement of the collision non-flexibility ξ and their initial speeds of the electrons and photons, but this evolution is lower than that in the high power laser field. When the electrons are captured by the laser field, the evolution is finished, and the electrons will stably transport,and the photons don't provide the energy for these electrons any more.

  3. Contrast and Intensity upgrades to the Texas Petawatt laser for hadron generation and non-linear QED experiments

    Science.gov (United States)

    Hegelich, Bjorn M.; Arefiev, Alexey; Ditmire, Todd; Donovan, Michael E.; Dyer, Gillis; Gaul, Erhard; Labun, Lance; Luedtke, Scott; Martinez, Mikael; McCarry, Edward; Stark, David; Pomerantz, Ishay; Tiwari, Ganesh; Toncian, Toma

    2015-11-01

    Advances in laser-based hadron generation, especially with respect to particle energy, as well as reaching the new regime of radiation dominated plasmas and non-linear QED, require laser fields of Petavolts per meter that preferably interact with very high density, overcritical plasmas. To achieve these conditions we are upgrading the Texas Petawatt Laser both respect to on-target laser intensity and laser-contrast, aiming to reach intensities of ~ 5x1022 W/cm2 and pulse contrast parameters allowing the interaction with overcritical, yet ultrathin, sub-micron targets. We will report on the planned experiments aimed at ion acceleration, neutron generation and the first experimental measurement of radiation reactions to motivate the chosen upgrade parameters. We will further report on the technical changes to the laser and present first measurements of the achieved intensity and contrast parameters. This work was supported by NNSA cooperative agreement DE-NA0002008, the Defense Advanced Research Projects Agency's PULSE program (12-63-PULSE-FP014), the Air Force Office of Scientific Research (FA9550-14-1-0045) and the National Institute of Health SBIR.

  4. Testing relativity again, laser, laser, laser, laser

    NARCIS (Netherlands)

    Einstein, A.

    2015-01-01

    laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser,

  5. Development of laser-induced fluorescence for precombustion diagnostics in spark-ignition engines

    Energy Technology Data Exchange (ETDEWEB)

    Neij, H.

    1998-11-01

    ) - was investigated with respect to optical properties relevant to laser-based combustion diagnostics, by flame emission, optical absorption, laser-induced fluorescence, spontaneous Raman scattering, and rotational CARS. The potential for LIF detection of water vapor in combustion processes was evaluated. Water molecules were excited in a two-photon process at 248 nm yielding fluorescence around 400-500 nm. Spectrally interfering species at flame conditions were identified as hot O{sub 2}, and laser-generated C{sub 2} and N{sub 2}{sup +}. The detection limit for two-dimensional single-shot detection of water vapor at atmospheric conditions was estimated to 0.2%. Extrapolations to flame conditions were presented. A pressure-dependent process was identified, which decreased the signal intensity, broadened the linewidths, and degraded the spectral-excitation feature as the ambient pressure was increased. Two-photon water vapor LIF was applied to a research engine for residual gas visualization. The accuracy and precision of both two-dimensional and spatially averaged data were discussed. The LIF data was used to explain the engine behavior on a cycle-by-cycle basis. A significant correlation was identified between the combustion event and the spatially averaged water signal around the spark gap at the time of ignition 181 refs, 26 figs, 7 tabs

  6. Development of laser-induced fluorescence for precombustion diagnostics in spark-ignition engines

    Energy Technology Data Exchange (ETDEWEB)

    Neij, H.

    1998-11-01

    ) - was investigated with respect to optical properties relevant to laser-based combustion diagnostics, by flame emission, optical absorption, laser-induced fluorescence, spontaneous Raman scattering, and rotational CARS. The potential for LIF detection of water vapor in combustion processes was evaluated. Water molecules were excited in a two-photon process at 248 nm yielding fluorescence around 400-500 nm. Spectrally interfering species at flame conditions were identified as hot O{sub 2}, and laser-generated C{sub 2} and N{sub 2}{sup +}. The detection limit for two-dimensional single-shot detection of water vapor at atmospheric conditions was estimated to 0.2%. Extrapolations to flame conditions were presented. A pressure-dependent process was identified, which decreased the signal intensity, broadened the linewidths, and degraded the spectral-excitation feature as the ambient pressure was increased. Two-photon water vapor LIF was applied to a research engine for residual gas visualization. The accuracy and precision of both two-dimensional and spatially averaged data were discussed. The LIF data was used to explain the engine behavior on a cycle-by-cycle basis. A significant correlation was identified between the combustion event and the spatially averaged water signal around the spark gap at the time of ignition 181 refs, 26 figs, 7 tabs

  7. Nonlinear two-photon absorption properties induced by femtosecond laser with the films of two novel anthracene derivatives

    Institute of Scientific and Technical Information of China (English)

    Liang Li; Yiqun Wu; Yang Wang

    2012-01-01

    Two novel anthracene derivatives containing 4-vinylpyridine (FPEA) and 2-vinylpyridine (TPEA) poly(methyl methacrylate) films are prepared on quartz glass substrates.Their nonlinear absorption properties are investigated by using a 120-fs,800-am Ti:sapphire femtosecond pulsed laser operating at a 1-kHz repetition rate.The unique nonlinear absorption properties of these new compounds are observed by utilizing a Z-scan system.These two-photon absorption (TPA) properties are proven by the two-photon fluorescence excited at 800 nm.The FPEA and TPEA films have nonlinear TPA coefficients of 0.164 and 0.148 cm/GW and the TPA cross sections of 3.345 × 10-48 and 3.081 × 10-48 cm4.s/photon,respectively.The influence of the chemical structures on the nonlinear TPA properties of the compounds is also discussed.The highly nonlinear TPA activities of the films implied that the new anthracene derivatives are suitable materials with promising applications in super-high-density three-dimensional data storage and nano- or microstructure fabrication.

  8. Coaxial CVD diamond detector for neutron diagnostics at ShenGuang III laser facility.

    Science.gov (United States)

    Yu, Bo; Liu, Shenye; Chen, Zhongjing; Huang, Tianxuan; Jiang, Wei; Chen, Bolun; Pu, Yudong; Yan, Ji; Zhang, Xing; Song, Zifeng; Tang, Qi; Hou, Lifei; Ding, Yongkun; Zheng, Jian

    2017-06-01

    A coaxial, high performance diamond detector has been developed for neutron diagnostics of inertial confinement fusion at ShenGuangIII laser facility. A Φ10 mm × 1 mm "optical grade" chemical-vapor deposition diamond wafer is assembled in coaxial-designing housing, and the signal is linked to a SubMiniature A connector by the cathode cone. The coaxial diamond detector performs excellently for neutron measurement with the full width at half maximum of response time to be 444 ps for a 50 Ω measurement system. The average sensitivity is 0.677 μV ns/n for 14 MeV (DT fusion) neutrons at an electric field of 1000 V/mm, and the linear dynamic range is beyond three orders of magnitude. The ion temperature results fluctuate widely from the neutron time-of-flight scintillator detector results because of the short flight length. These characteristics of small size, large linear dynamic range, and insensitive to x-ray make the diamond detector suitable to measure the neutron yield, ion temperature, and neutron emission time.

  9. Diagnostic accuracy of laser Doppler imaging in burn depth assessment: Systematic review and meta-analysis.

    Science.gov (United States)

    Shin, Jin Yong; Yi, Hyung Suk

    2016-11-01

    Accurate assessment of burn depth is important for determination of treatment modality. Laser Doppler imaging (LDI) is known to be an objective and effective measurement tool in burn depth assessment. Our study evaluated the diagnostic accuracy of LDI across enrolled studies and subgroups. A systematic literature review and meta-analysis were performed using MEDLINE, EMBASE, and Cochrane databases. Data from LDI cases were extracted from all primary studies and categorized into four cell values (true positives, false positives, true negatives, and false negatives). Subgroup analyses were performed according to perfusion units of LDI, clinical criteria of superficial and deep burns during the treatment period, and publication date of enrolled studies. The search strategy identified 321 publications. After screening, 10 articles were selected for review. The pooled sensitivity and specificity of LDI in all enrolled studies and subgroups were found to be similarly high. However, the sensitivity of LDI in our meta-analysis was not as high as that identified in previous studies. Although LDI in burn depth assessment was identified as an accurate measurement tool in this meta-analysis, careful clinical assessment should be performed along with LDI in patients with deep burns. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  10. Diagnostic development in precise opacity measurement of radiatively heated Al plasma on Shenguang II laser facility

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Yang [Wuhan National Laboratory for Optoelectronics, Institute of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yang Jiamin; Zhang Jiyan [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Liu Jinsong; Yuan Xiao [Wuhan National Laboratory for Optoelectronics, Institute of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Jin Fengtao [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Department of Physics, National University of Defense Technology, Changsha 410073 (China)

    2009-04-15

    Simultaneous measurements of the self-emission spectrum, the backlighting source spectrum, and the transmission spectrum in one shot, which reduce the experimental uncertainties from shot-to-shot fluctuation, are essential for precise opacity experiments. In order to achieve precise absorption spectrum of Al plasmas, a special half sample sandwich target was designed and short backlighter was used to provide time- and space-resolving diagnostics on the Shenguang II high power laser facility. In the measurement, a cylindrical cavity with CH foam baffles was used to provide a clean x-ray radiation environment for sample heating. The x-ray source spectrum, the transmission spectrum, and the self-emission spectrum of the soft x-ray heated Al sample were recorded in one shot with a penta-erythritol tetrakis (hydroxymethy) methane C(CH{sub 2}OH){sub 4} (PET) crystal spectrometer by using the point-projection method. Experimental results have been compared with the calculation results of a detailed level accounting opacity code.

  11. Laser diagnostic technology for early detection of pathogen infestation in orange fruits

    Energy Technology Data Exchange (ETDEWEB)

    Giubileo, Gianfranco, E-mail: gianfranco.giubileo@frascati.enea.i [ENEA Frascati, Via E. Fermi 45, 00044 (Italy); Lai, Antonella; Piccinelli, Delinda [ENEA Frascati, Via E. Fermi 45, 00044 (Italy); Puiu, Adriana [Tor Vergata University of Rome, Faculty of Engineering, Via del Politecnico 1, 00133 Rome (Italy)

    2010-11-11

    Due to an increased expectation of food products that respect high quality and safety standards, there is a need for the growth of accurate, fast, objective and non-destructive technologies for quality determination of food and agricultural products. For this purpose, a diagnostic system based on laser photoacoustic spectroscopy (LPAS) was developed at ENEA Frascati Molecular Spectroscopy Laboratory (Italy). In the design of the photoacoustic detector, particular emphasis was placed in attaining a high sensitivity in detecting ethylene (ET) down to sub-parts per billion level (minimum detectable concentration 0.2 ppb). This was required due to the necessity to monitor and follow up ET production at a single fruit scale. ET is normally synthesised in very low amounts by healthy citrus fruits; however stress conditions such as pathogen attack may induce a substantial increase in the synthesised ET. In the present paper, the comparison between the ET emitted by healthy oranges (Citrus sinensis L. Osbeck) cv Navel and by Phytophthora citrophthora infested Navel orange fruits are reported. The obtained results show a well evident increase in ET emission from the infested fruit with respect to the healthy one, even 24 h after the inoculation with the pathogen; at that time the tissue necrosis was not yet visible, and the fruit was also not yet damaged. The possibility to perform a real time non-destructive detection of ET traces makes the LPAS a powerful tool for monitoring the healthy state of the citrus fruits.

  12. 5.5 W of Diffraction-Limited Green Light Generated by SFG of Tapered Diode Lasers in a Cascade of Nonlinear Crystals

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh; Jensen, Ole Bjarlin; Andersen, Peter Eskil

    2015-01-01

    Diode-based high power visible lasers are perfect pump sources for, e.g., titaniumsapphire lasers. The combination of favorable scaling laws in both SFG and cascading of nonlinear crystals allows access to unprecedented powers in diode-based systems....

  13. Ti : sapphire laser synchronised with femtosecond Yb pump laser via nonlinear pulse coupling in Ti : sapphire active medium

    Science.gov (United States)

    Didenko, N. V.; Konyashchenko, A. V.; Konyashchenko, D. A.; Kostryukov, P. V.; Kuritsyn, I. I.; Lutsenko, A. P.; Mavritskiy, A. O.

    2017-02-01

    A laser system utilising the method of synchronous pumping of a Ti : sapphire laser by a high-power femtosecond Yb3+-doped laser is described. The pulse repetition rate of the Ti : sapphire laser is successfully locked to the repetition rate of the Yb laser for more than 6 hours without the use of any additional electronics. The measured timing jitter is shown to be less than 1 fs. A simple qualitative model addressing the synchronisation mechanism utilising the cross-phase modulation of oscillation and pump pulses within a Ti : sapphire active medium is proposed. Output parameters of the Ti : sapphire laser as functions of its cavity length are discussed in terms of this model.

  14. Laser Plasmas : Lie-optics, geometrical phase and nonlinear dynamics of self-focusing and soliton evolution in a plasma

    Indian Academy of Sciences (India)

    D Subbarao; R Uma; H Singh; Kamal Goyal; Sanjeev Goyal; Ravinder Kumar

    2000-11-01

    It is useful to state propagation laws for a self-focusing laser beam or a soliton in grouptheoretical form to be called Lie-optical form for being able to predict self-focusing dynamics conveniently and amongst other things, the geometrical phase. It is shown that the propagation of the gaussian laser beam is governed by a rotation group in a non-absorbing medium and by the Lorentz group in an absorbing medium if the additional symmetry of paraxial propagation is imposed on the laser beam. This latter symmetry, however, needs care in its implementation because the electromagnetic wave of the laser sees a different refractive index profile than the laboratory observer in this approximation. It is explained how to estimate this non-Taylor paraxial power series approximation. The group theoretical laws so-stated are used to predict the geometrical or Berry phase of the laser beam by a technique developed by one of us elsewhere. The group-theoretical Lie-optic (or ABCD) laws are also useful in predicting the laser behavior in a more complex optical arrangement like in a laser cavity etc. The nonlinear dynamical consequences of these laws for long distance (or time) predictions are also dealt with. Ergodic dynamics of an ensemble of laser beams on the torus during absorptionless self-focusing is discussed in this context. From the point of view of new physics concepts, we introduce a stroboscopic invariant torus and a stroboscopic generating function in classical mechanics that is useful for long-distance predictions of absorptionless self-focusing.

  15. 2011 Laser Diagnostics in Combustion Gordon Research Conference, (August 14-19, 2011, Waterville Valley Resort, Waterville Valley, NH)

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Settersten

    2011-08-19

    The vast majority of the world's energy needs are met by combustion of fossil fuels. Optimum utilization of limited resources and control of emissions of pollutants and greenhouse gases demand sustained improvement of combustion technology. This task can be satisfied only by detailed knowledge of the underlying physical and chemical processes. Non-intrusive laser diagnostics continuously contribute to our growing understanding of these complex and coupled multi-scale processes. The GRC on Laser Diagnostics in Combustion focuses on the most recent scientific advances and brings together scientists and engineers working at the leading edge of combustion research. Major tasks of the community are developing and applying methods for precise and accurate measurements of fluid motion and temperatures; chemical compositions; multi-phase phenomena appearing near walls, in spray and sooting combustion; improving sensitivities, precision, spatial resolution and tracking transients in their spatio-temporal development. The properties and behaviour of novel laser sources, detectors, optical systems that lead to new diagnostic capabilities are also part of the conference program.

  16. Measurements of nonlinear lensing in a semiconductor disk laser gain sample under optical pumping and using a resonant femtosecond probe laser

    Science.gov (United States)

    Quarterman, A. H.; Mirkhanov, S.; Smyth, C. J. C.; Wilcox, K. G.

    2016-09-01

    Accurate characterizations of the nonlinear refractive index of semiconductor disk laser (SDL) gain samples are of critical importance for understanding the behavior of self-mode-locked SDLs. Here we describe measurements of nonlinear lensing in an SDL gain sample for a wide range of optical pump intensities and using a probe which is on resonance with the quantum wells in the SDL gain sample and whose intensity, pulse duration, and spot size are chosen to be similar to those reported in self-mode-locked SDLs. Under these conditions, we determine an effective value of the nonlinear refractive index, n2 = -6.5 × 10-13 cm2/W at zero pump intensity, and find that the value of n2 changes by less than 25% over the range of pump intensities studied. The nonlinear refractive index is measured using a variation on the well-established z-scan technique, which was modified to make it better suited to the measurement of optically pumped samples.

  17. Mueller-matrix of laser-induced autofluorescence of polycrystalline films of dried peritoneal fluid in diagnostics of endometriosis

    Science.gov (United States)

    Ushenko, Yuriy A.; Koval, Galina D.; Ushenko, Alexander G.; Dubolazov, Olexander V.; Ushenko, Vladimir A.; Novakovskaia, Olga Yu.

    2016-07-01

    This research presents investigation results of the diagnostic efficiency of an azimuthally stable Mueller-matrix method of analysis of laser autofluorescence of polycrystalline films of dried uterine cavity peritoneal fluid. A model of the generalized optical anisotropy of films of dried peritoneal fluid is proposed in order to define the processes of laser autofluorescence. The influence of complex mechanisms of both phase (linear and circular birefringence) and amplitude (linear and circular dichroism) anisotropies is taken into consideration. The interconnections between the azimuthally stable Mueller-matrix elements characterizing laser autofluorescence and different mechanisms of optical anisotropy are determined. The statistical analysis of coordinate distributions of such Mueller-matrix rotation invariants is proposed. Thereupon the quantitative criteria (statistic moments of the first to the fourth order) of differentiation of polycrystalline films of dried peritoneal fluid, group 1 (healthy donors) and group 2 (uterus endometriosis patients), are determined.

  18. Time-Resolved Spectroscopy Diagnostic of Laser-Induced Optical Breakdown

    OpenAIRE

    Parigger, Christian G.; Hornkohl, James O.; László Nemes

    2010-01-01

    Transient laser plasma is generated in laser-induced optical breakdown (LIOB). Here we report experiments conducted with 10.6-micron CO2 laser radiation, and with 1.064-micron fundamental, 0.532-micron frequency-doubled, 0.355-micron frequency-tripled Nd:YAG laser radiation. Characterization of laser induced plasma utilizes laser-induced breakdown spectroscopy (LIBS) techniques. Atomic hydrogen Balmer series emissions show electron number density of 1017 cm−3 measured approximately 10 μs and ...

  19. Generation of Nonlinear Force Driven Blocks from Skin Layer Interaction of Petawatt-Picosecond Laser Pulses for ICF

    Institute of Scientific and Technical Information of China (English)

    Heinrich Hora; K. Jungwirth; B. Kralikova; J. Kraska; L. Laska; Liu Hong; G.H. Miley; P. Parys; Peng Hansheng; M. Pfeifer; K. Rohlena; Cang Yu; J. Skala; Z. Skladanowski; L. Torrisi; J. Ullschmied; J. Wolowski; Zhang Weiyan; He Xiantu; Zhang Jie; F. Osman; J. Badziak; F.P. Boody; S. Gammino; R. H(o)pfl

    2004-01-01

    The discovery of the essential difference of maximum ion energy for TW-ps laser plasma interaction compared with the 100 ns laser pulses [1] led to the theory of a skin layer model [2] where the control of prepulses suppressed the usual relativistic self-focusing. The subsequent generation of two nonlinear force driven blocks has been demonstrated experimentally and in extensive numerical studies where one block moves against the laser light and the other block into the irradiated target. These blocks of nearly solid state density DT plasma correspond to ion beam current densities [3] exceeding 1010 A/cm2 where the ion velocity can be chosen up to highly relativistic values. Using the results of the expected ignition of DT fuel by light ion beams, a selfsustained fusion reaction front may be generated even into uncompressed solid DT fuel similar to the Nuckolls-Wood [4] scheme where 10 kJ laser pulses produce 100 MJ fusion energy. This new and simplified scheme of laser-ICF needs and optimisation of the involved parameters.

  20. Nonlinear interaction of ultraintense laser pulse with relativistic thin plasma foil in the radiation pressure-dominant regime

    Indian Academy of Sciences (India)

    KRISHNA KUMAR SONI; K P MAHESHWARI

    2016-11-01

    We present a study of the effect of laser pulse temporal profile on the energy/momentum acquired by the ions as a result of the ultraintense laser pulse focussed on a thin plasma layer in the radiation pressuredominant(RPD) regime. In the RPD regime, the plasma foil is pushed by ultraintense laser pulse when the radiation cannot propagate through the foil, while the electron and ion layers move together. The nonlinear character of laser–matter interaction is exhibited in the relativistic frequency shift, and also change in the wave amplitude as the EM wave gets reflected by the relativistically moving thin dense plasma layer. Relativistic effects in a highenergy plasma provide matching conditions that make it possible to exchange very effectively ordered kineticenergy and momentum between the EM fields and the plasma. When matter moves at relativistic velocities, the efficiency of the energy transfer from the radiation to thin plasma foil is more than 30% and in ultrarelativisticcase it approaches one. The momentum/energy transfer to the ions is found to depend on the temporal profile of the laser pulse. Our numerical results show that for the same laser and plasma parameters, a Lorentzian pulse canaccelerate ions upto 0.2 GeV within 10 fs which is 1.5 times larger than that a Gaussian pulse can.

  1. Scanning laser polarimetry: »number« parameter sensitivity and specificity in glaucoma diagnostics

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2005-10-01

    Full Text Available Background: Scanning laser polarimetry (SLP is a method that enables quantitative assessment of retinal nerve fibre layer (RNFL thickness surrounding the optic nerve. The commercially available device GDx (GDx, Laser Diagnostics Technologies, San Diego, CA yields an outprint consisting of a reflectance image, colour-coded retardation map, and the 14 parameters, of which the »Number« was shown to be the single best parameter to discriminate between glaucomatous and normal eyes. The »Number« is a probability score, ranging from 1 (low probability of glaucoma to 100 (high probability of glaucoma. In our study we determined the sensitivity and the specificity of the »Number« at cutoff values of 23 and 30. Methods: Thirty patients with different stage of glaucoma and 14 patients with typical glaucomatous changes of the ONH without visual field loss (preperimetric glaucoma were included in the analysis. The control group was represented by 27 adults without ocular pathology with intraocular pressure of < 21 mmHg and normal visual fields. The sensitivity and specificity of the »Number« was determined at a cut-off level of 23 and 30. Results: The sensitivity of the »Number« at a cut-off level of 30 for the glaucoma group was 74% at a specificity of 86%, at a cut-off of 23 the sensitivity increased to 83% at a specificity of 76%. The discriminating ability of the »Number« in the group with preperimetric glaucoma was low, with the sensitivities of 36% and 50% at a cut-off value of 30 and 23, respectively.Conclusions: The parameter »Number« yielded good separation between normal eyes and eyes with moderate and advanced glaucoma. However, the sensitivity of the »Number« in eyes with mild glaucoma and especially with preperimetric glaucoma was low. Because of the great interindividual variability of the RNFL, the assessment of RNFL thickness change over time would be more appropriate to detect early glaucomatous changes.

  2. Growth of γ-alumina thin films by pulsed laser deposition and plasma diagnostic

    Science.gov (United States)

    Yahiaoui, K.; Abdelli-Messaci, S.; Messaoud Aberkane, S.; Siad, M.; Kellou, A.

    2017-07-01

    The present work discusses about the synthesis of alumina thin films, which have applications in current and next-generation solid-state electronic devices due to their attractive properties. Alumina thin films were synthesized by pulsed laser deposition at different oxygen pressures and substrate temperatures. The dependence of substrate temperature, oxygen pressure, and the deposition time on the properties of the films has been observed by growing three series of alumina thin films on Si (100). The first films are synthesized using substrate temperatures ranging from room temperature to 780 °C at 0.01 mbar of O2. The second series was realized at a fixed substrate temperature of 760 °C and varied oxygen pressure (from 0.005 to 0.05 mbar). The third set of series was elaborated at different deposition times (from 15 to 60 min) while the oxygen pressure and the substrate temperature were fixed at 0.01 mbar and 760 °C, respectively. The films were characterized using X-ray diffractometer (XRD) for structural analysis, a scanning electron microscope for morphological analysis, a nano-indenter for mechanical analysis (hardness and Young's modulus), and Rutherford backscattering spectroscopy for thickness and stoichiometry measurements. Using optical emission spectroscopy, plasma diagnostic was carried out both in the vacuum and in the presence of oxygen with a pressure ranging from 0.01 to 0.05 mbar. Several neutral, ionic, and molecular species were identified such as Al, Al+, and Al++ in vacuum and in oxygen ambiance, O and AlO molecular bands in oxygen-ambient atmosphere. The spatiotemporal evolution of the most relevant species was achieved and their velocities were estimated. The highest amount of crystallized alumina in γ-phase was found in the films elaborated under 0.01 mbar of O2, at a substrate temperature of 780 °C, and a deposition time of 60 min.

  3. Nonlinear dynamics of high-power ultrashort laser pulses: exaflop computations on a laboratory computer station and subcycle light bullets

    Science.gov (United States)

    Voronin, A. A.; Zheltikov, A. M.

    2016-09-01

    The propagation of high-power ultrashort light pulses involves intricate nonlinear spatio-temporal dynamics where various spectral-temporal field transformation effects are strongly coupled to the beam dynamics, which, in turn, varies from the leading to the trailing edge of the pulse. Analysis of this nonlinear dynamics, accompanied by spatial instabilities, beam breakup into multiple filaments, and unique phenomena leading to the generation of extremely short optical field waveforms, is equivalent in its computational complexity to a simulation of the time evolution of a few billion-dimensional physical system. Such an analysis requires exaflops of computational operations and is usually performed on high-performance supercomputers. Here, we present methods of physical modeling and numerical analysis that allow problems of this class to be solved on a laboratory computer boosted by a cluster of graphic accelerators. Exaflop computations performed with the application of these methods reveal new unique phenomena in the spatio-temporal dynamics of high-power ultrashort laser pulses. We demonstrate that unprecedentedly short light bullets can be generated as a part of that dynamics, providing optical field localization in both space and time through a delicate balance between dispersion and nonlinearity with simultaneous suppression of diffraction-induced beam divergence due to the joint effect of Kerr and ionization nonlinearities.

  4. Fiber lasers for medical diagnostics and treatments: state of the art, challenges and future perspectives

    Science.gov (United States)

    Taccheo, Stefano

    2017-02-01

    Fiber laser is a fast growing yet quite young type of laser with huge potential in healthcare due to versatility and reliability. The talk discusses present and future for fiber lasers for medical applications and address future challenges and competitions with other sources.

  5. Optical, structural and nonlinear optical properties of laser ablation synthesized Ag nanoparticles and photopolymer nanocomposites based on them

    Science.gov (United States)

    Zulina, Natalia A.; Pavlovetc, Ilia M.; Baranov, Mikhail A.; Denisyuk, Igor Yu.

    2017-03-01

    In this work Ag nanoparticles (NPs) stable colloid solution were prepared by laser ablation of chemically pure silver rod in liquid monomer isodecyl acrylate (IDA). Sizes of obtained nanoparticles were determined by scanning electron microscope and vary from 27 to 120 nm. Nanocomposites films were prepared from obtained stable colloid solution of AgNPs by photocuring. For aliphatic polymer IDA long molecules cross-linking Diurethane dimethacrylate, 1,6-Hexandiol diacrylate and Tetra (ethylene glycol) diacrylate were used. Prepared nanomaterials exhibit strong third-order nonlinear optical responses, which was estimated by using z-scan technique. The third-order nonlinear optical coefficients of the studied nanocomposites were found to be up to Reχ(3)=1.31×10-5 (esu) and Imχ(3)=7.64×10-5 (esu).

  6. The ''phase velocity'' of nonlinear plasma waves in the laser beat-wave accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Spence, W.L.

    1985-04-01

    A calculational scheme for beat-wave accelerators is introduced that includes all orders in velocity and in plasma density, and additionally accounts for the influence of plasma nonlinearities on the wave's phase velocity. The main assumption is that the laser frequencies are very large compared to the plasma frequency - under which it is possible to sum up all orders of forward Raman scattering. It is found that the nonlinear plasma wave does not have simply a single phase velocity, but that the beat-wave which drives it is usefully described by a non-local ''effective phase velocity'' function. A time-space domain approach is followed. (LEW)

  7. Nonlinear processes associated with the amplification of MHz-linewidth laser pulses in single-mode Tm:fiber

    Science.gov (United States)

    Sincore, Alex; Bodnar, Nathan; Bradford, Joshua; Abdulfattah, Ali; Shah, Lawrence; Richardson, Martin C.

    2017-03-01

    This work studies the accumulated nonlinearities when amplifying a narrow linewidth 2053 nm seed in a single mode Tm:fiber amplifier. A control of repetition rate and pulse duration (>30 ns). The pulses are subsequently amplified and the repetition rate is further reduced using a second acousto-optic modulator. It is well known that spectral degradation occurs in such fibers for peak powers over 100's of watts due to self-phase modulation, four-wave mixing, and stimulated Raman scattering. In addition to enabling a thorough test bed to study such spectral broadening, this system will also enable the investigation of stimulated Brillouin scattering thresholds in the same system. This detailed study of the nonlinearities encountered in 2 μm fiber amplifiers is important in a range of applications from telecommunications to the amplification of ultrashort laser pulses.

  8. Efficient Second Harmonic Generation in 3D Nonlinear Optical-Lattice-Like Cladding Waveguide Splitters by Femtosecond Laser Inscription.

    Science.gov (United States)

    Nie, Weijie; Jia, Yuechen; Vázquez de Aldana, Javier R; Chen, Feng

    2016-02-29

    Integrated photonic devices with beam splitting function are intriguing for a broad range of photonic applications. Through optical-lattice-like cladding waveguide structures fabricated by direct femtosecond laser writing, the light propagation can be engineered via the track-confined refractive index profiles, achieving tailored output beam distributions. In this work, we report on the fabrication of 3D laser-written optical-lattice-like structures in a nonlinear KTP crystal to implement 1 × 4 beam splitting. Second harmonic generation (SHG) of green light through these nonlinear waveguide beam splitter structures provides the capability for the compact visible laser emitting devices. With Type II phase matching of the fundamental wavelength (@ 1064 nm) to second harmonic waves (@ 532 nm), the frequency doubling has been achieved through this three-dimensional beam splitter. Under 1064-nm continuous-wave fundamental-wavelength pump beam, guided-wave SHG at 532 nm are measured with the maximum power of 0.65 mW and 0.48 mW for waveguide splitters (0.67 mW and 0.51 mW for corresponding straight channel waveguides), corresponding to a SH conversion efficiency of approximately ~14.3%/W and 13.9%/W (11.2%/W, 11.3%/W for corresponding straight channel waveguides), respectively. This work paves a way to fabricate compact integrated nonlinear photonic devices in a single chip with beam dividing functions.

  9. Diode array pumped, non-linear mirror Q-switched and mode-locked Nd : YVO4 laser – a good tool for powder SHG measurement

    Indian Academy of Sciences (India)

    P K Datta; Chandrajit Basu; S Mukhopadhyay; S K Das; G K Samanta; Antonio Agnesi

    2004-11-01

    A non-linear mirror consisting of a lithium triborate crystal and a dichroic output coupler are used to mode-lock (passively) an Nd : YVO4 laser, pumped by a diode laser array. The laser can operate both in cw mode-locked and simultaneously Q-switched and mode-locked (QML) regime. The peak power of the laser while operating in QML regime is much higher but pulses suffers from poor amplitude stability. The incorporation of an acousto-optic modulator as an active Q-switch enhances the stability of the QML pulse envelope. The second-order non-linearity of powdered crystalline urea is conclusively measured with respect to KDP while the laser is operating in passively Q-switched and passively mode-locked regime as well as in actively Q-switched and passively mode-locked regime.

  10. Bulk growth, structure, optical properties and laser damage threshold of organic nonlinear optical crystals of Imidazolium L-Ascorbate

    Science.gov (United States)

    Saripalli, Ravi Kiran; Bhat, H. L.; Elizabeth, Suja

    2016-09-01

    Bulk, transparent organic nonlinear optical (NLO) single-crystals of imidazolium L-Ascorbate (ImLA) were grown using slow-evaporation. Crystal structure was determined by single crystal X-ray diffraction analysis. Preliminary linear optical measurements through UV-Visible and infrared spectroscopy revealed good optical transmittance and a low near-UV cutoff wavelength at 256 nm. Kurtz and Perry powder test revealed that ImLA is a phase-matchable NLO material with a second harmonic generation (SHG) efficiency of 1.2 times larger than that of standard KH2PO4 (KDP). Laser damage thresholds were determined for ImLA.

  11. Multiwavelength erbium-doped fiber laser based on a nonlinear amplifying loop mirror assisted by un-pumped EDF.

    Science.gov (United States)

    Liu, Xuesong; Zhan, Li; Luo, Shouyu; Gu, Zhaochang; Liu, Jinmei; Wang, Yuxing; Shen, Qishun

    2012-03-26

    A multiwavelength erbium-doped fiber (EDF) laser based on a nonlinear amplifying loop mirror (NALM) is proposed and experimentally demonstrated. The NALM provides intensity-dependent transmissivity to equalize different-wavelength powers and the transmission can be uniquely optimized by controlling the cavity loss associated with a section of un-pumped EDF, which also enhances the output signal-to-noise ratio (SNR). Through adjusting the polarization controllers (PCs), under only 70 mW pump power, up to 62-wavelength output with channel spacing of 0.45 nm has been achieved. Also, the lasing tunability and stability are verified.

  12. Design of triangular core LMA-PCF with low-bending loss and low non-linearity for laser application

    Science.gov (United States)

    Kabir, Sumaiya; Khandokar, Md. Rezwanul Haque; Khan, Muhammad Abdul Goffar

    2016-07-01

    In this paper we characterize the design of a simple large-mode area photonic crystal fiber (LMA-PCF) with low bending loss and low non-linearity. The finite element method (FEM) with perfectly matched boundary layer (PML) is used to investigate the guiding properties. According to simulation the characterized four ring fluorine doped triangular core LMA-PCF achieves 1500 μm2 effective mode area with a low bending loss of 10-5dB/km at the wavelength of 1.064 μm and at a bending radius of 40 cm which is suitable for high power fiber laser.

  13. Picosecond 1.3{-}\\unicode{956} {\\text{m}} bismuth fibre laser mode-locked by a nonlinear loop mirror

    Science.gov (United States)

    Khegai, A. M.; Afanas'ev, F. V.; Riumkin, K. E.; Firstov, S. V.; Khopin, V. F.; Myasnikov, D. V.; Mel'kumov, M. A.; Dianov, E. M.

    2016-12-01

    The influence of the concentration of bismuth active centres (BACs) in phosphosilicate fibres on their optical parameters, including gain coefficient and non-saturable losses, has been studied. A range of BAC concentrations optimal for designing ultrashort-pulse (USP) lasers was chosen based on the obtained results. The optimised fibre was used to fabricate an all-fibre 1.3-\\unicode{956}{\\text{m}} USP laser mode-locked by a nonlinear loop mirror, which emits 11.3-{\\text{ps}} pulses with an energy of 1.65 {\\text{nJ}} and a repetition rate of 3.6 {\\text{MHz}}. A bismuth fibre amplifier made it possible to increase the pulse energy to 8.3 {\\text{nJ}}. After compression in a diffraction grating compressor, the pulse duration decreased to 530 {\\text{fs}}.

  14. State Space Formulation of Nonlinear Vibration Responses Collected from a Dynamic Rotor-Bearing System: An Extension of Bearing Diagnostics to Bearing Prognostics

    Directory of Open Access Journals (Sweden)

    Peter W. Tse

    2017-02-01

    Full Text Available Bearings are widely used in various industries to support rotating shafts. Their failures accelerate failures of other adjacent components and may cause unexpected machine breakdowns. In recent years, nonlinear vibration responses collected from a dynamic rotor-bearing system have been widely analyzed for bearing diagnostics. Numerous methods have been proposed to identify different bearing faults. However, these methods are unable to predict the future health conditions of bearings. To extend bearing diagnostics to bearing prognostics, this paper reports the design of a state space formulation of nonlinear vibration responses collected from a dynamic rotor-bearing system in order to intelligently predict bearing remaining useful life (RUL. Firstly, analyses of nonlinear vibration responses were conducted to construct a bearing health indicator (BHI so as to assess the current bearing health condition. Secondly, a state space model of the BHI was developed to mathematically track the health evolution of the BHI. Thirdly, unscented particle filtering was used to predict bearing RUL. Lastly, a new bearing acceleration life testing setup was designed to collect natural bearing degradation data, which were used to validate the effectiveness of the proposed bearing prognostic method. Results show that the prediction accuracy of the proposed bearing prognostic method is promising and the proposed bearing prognostic method is able to reflect future bearing health conditions.

  15. Combined nonlinear laser imaging (two-photon excitation fluorescence, second and third-harmonic generation, and fluorescence lifetime imaging microscopies) in ovarian tumors

    Science.gov (United States)

    Adur, J.; Pelegati, V. B.; de Thomaz, A. A.; Bottcher-Luiz, F.; Andrade, L. A. L. A.; Almeida, D. B.; Carvalho, H. F.; Cesar, C. L.

    2012-03-01

    We applied Two-photon Excited Fluorescence (TPEF), Second/Third Harmonic Generation (SHG and THG) and Fluorescence Lifetime Imaging (FLIM) Non Linear Optics (NLO) Laser-Scanning Microscopy within the same imaging platform to evaluate their use as a diagnostic tool in ovarian tumors. We assess of applicability of this multimodal approach to perform a pathological evaluation of serous and mucinous tumors in human samples. The combination of TPEF-SHG-THG imaging provided complementary information about the interface epithelium/stromal, such as the transformation of epithelium surface (THG) and the overall fibrillar tissue architecture (SHG). The fact that H&E staining is the standard method used in clinical pathology and that the stored samples are usually fixed makes it important a re-evaluation of these samples with NLO microscopy to compare new results with a library of already existing samples. FLIM, however, depends on the chemical environment around the fluorophors that was completely changed after fixation; therefore it only makes sense in unstained samples. Our FLIM results in unstained samples demonstrate that it is possible to discriminate healthy epithelia from serous or mucinous epithelia. Qualitative and quantitative analysis of the different imaging modalities used showed that multimodal nonlinear microscopy has the potential to differentiate between cancerous and healthy ovarian tissue.

  16. Applicability of quantitative optical imaging techniques for intraoperative perfusion diagnostics: a comparison of laser speckle contrast imaging, sidestream dark-field microscopy, and optical coherence tomography

    Science.gov (United States)

    Jansen, Sanne M.; de Bruin, Daniel M.; Faber, Dirk J.; Dobbe, Iwan J. G. G.; Heeg, Erik; Milstein, Dan M. J.; Strackee, Simon D.; van Leeuwen, Ton G.

    2017-08-01

    Patient morbidity and mortality due to hemodynamic complications are a major problem in surgery. Optical techniques can image blood flow in real-time and high-resolution, thereby enabling perfusion monitoring intraoperatively. We tested the feasibility and validity of laser speckle contrast imaging (LSCI), optical coherence tomography (OCT), and sidestream dark-field microscopy (SDF) for perfusion diagnostics in a phantom model using whole blood. Microvessels with diameters of 50, 100, and 400 μm were constructed in a scattering phantom. Perfusion was simulated by pumping heparinized human whole blood at five velocities (0 to 20 mm/s). Vessel diameter and blood flow velocity were assessed with LSCI, OCT, and SDF. Quantification of vessel diameter was feasible with OCT and SDF. LSCI could only visualize the 400-μm vessel, perfusion units scaled nonlinearly with blood velocity. OCT could assess blood flow velocity in terms of inverse OCT speckle decorrelation time. SDF was not feasible to measure blood flow; however, for diluted blood the measurements were linear with the input velocity up to 1 mm/s. LSCI, OCT, and SDF were feasible to visualize blood flow. Validated blood flow velocity measurements intraoperatively in the desired parameter (mL·g-1) remain challenging.

  17. Applicability of quantitative optical imaging techniques for intraoperative perfusion diagnostics: a comparison of laser speckle contrast imaging, sidestream dark-field microscopy, and optical coherence tomography.

    Science.gov (United States)

    Jansen, Sanne M; de Bruin, Daniel M; Faber, Dirk J; Dobbe, Iwan J G G; Heeg, Erik; Milstein, Dan M J; Strackee, Simon D; van Leeuwen, Ton G

    2017-08-01

    Patient morbidity and mortality due to hemodynamic complications are a major problem in surgery. Optical techniques can image blood flow in real-time and high-resolution, thereby enabling perfusion monitoring intraoperatively. We tested the feasibility and validity of laser speckle contrast imaging (LSCI), optical coherence tomography (OCT), and sidestream dark-field microscopy (SDF) for perfusion diagnostics in a phantom model using whole blood. Microvessels with diameters of 50, 100, and 400  μm were constructed in a scattering phantom. Perfusion was simulated by pumping heparinized human whole blood at five velocities (0 to 20  mm/s). Vessel diameter and blood flow velocity were assessed with LSCI, OCT, and SDF. Quantification of vessel diameter was feasible with OCT and SDF. LSCI could only visualize the 400-μm vessel, perfusion units scaled nonlinearly with blood velocity. OCT could assess blood flow velocity in terms of inverse OCT speckle decorrelation time. SDF was not feasible to measure blood flow; however, for diluted blood the measurements were linear with the input velocity up to 1  mm/s. LSCI, OCT, and SDF were feasible to visualize blood flow. Validated blood flow velocity measurements intraoperatively in the desired parameter (mL·min-1·g-1) remain challenging. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  18. Nonlinear Bethe-Heitler Pair Creation in an Intense Two-Mode Laser Field

    CERN Document Server

    Augustin, Sven

    2013-01-01

    We investigate electron-positron pair creation in the interaction of a nuclear Coulomb field and a highly intense two-mode laser field. For bichromatic laser fields, we examine the differences arising for commensurable and incommensurable frequencies in a continuous variation of the laser frequency ratio and the quantum interference effects, which may occur in the commensurable case. We show that the interference manifests in the angular distributions and the total pair-production rates of the created particles. Additionally, by varying the amplitudes of the two modes we study pair creation in a monochromatic laser wave of arbitrarily elliptical polarization.

  19. Nonlinear absorption coefficient of pulsed laser deposited MgZnO thin film

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, Arpana, E-mail: agrawal.arpana01@gmail.com; Dar, Tanveer A.; Solanki, Ravi; Sen, Pratima [Laser Bhawan, School of Physics, Devi Ahilya University, Khandwa Road, Indore-452001 (India); Phase, D. M. [UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore 452001 (India)

    2015-06-24

    We report the imaginary part of 3{sup rd} order nonlinear susceptibility and the nonlinear absorption coefficient of Mg doped ZnO thin film using standard Z-scan technique. The origin of nonlinear absorption is attributed to the two photon absorption followed by the free carrier absorption because of the presence of oxygen vacancy defects. We have also confirmed the experimental results with the theoretical results obtained by considering the steady state response of a two level atom with the monochromatic field models.

  20. Capabilities of laser technology for manufacturing diagnostic peptide matrices with maximal density

    Science.gov (United States)

    Baum, O. I.; Shcherbakov, E. M.; Nesterov-Müller, A.; Sobol', E. N.

    2016-02-01

    The process of manufacturing a matrix-gel biochip is modelled by means of laser fused deposition of a layer of polymer microparticles, containing a sensitive peptide element, onto a glass substrate. The limits of acceptable ranges and the optimal values of laser parameters, at which the melting of the polymer coating occurs without damaging the sensitive elements of the biochip, are theoretically determined. The results of the experiments on laser fused deposition of a layer of microparticles having the size 3 - 4 μm confirm the conservation of the functions of the biological complexes at optimal irradiation regimes. The parameters of the laser impact affecting the possible minimal separation between the zones of laser fused deposition are investigated. The essential role of heat conductivity and thermoplasticity of the polymer in increasing the size of the melted droplet is demonstrated. Using the laser radiation with the wavelength 532 nm focused into a spot with the diameter 6 μm (the laser pulse duration being 10 ms) the laser fused deposition density of 110000 spots per 1 cm2 is achieved. The maximal estimated density of laser fused deposition for the studied system amounts to 250000 spots per 1 cm2.

  1. Final Report for Statistical Nonlinear Optics of High Energy Density Plasmas: The Physics of Multiple Crossing Laser Beams

    Energy Technology Data Exchange (ETDEWEB)

    Afeyan, Bedros [Polymath Research Inc., Pleasanton, CA (United States); Hueller, Stefan [Centre de Physique Theorique de l' Ecole Polytechnique (France); Montgomery, David S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hammer, James H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Meezan, Nathan B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Heebner, John E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-24

    The various implementations of the STUD pulse program (spike trains of uneven duration and delay) for LPI (laser-plasma instability) control were studied in depth, and novel regimes were found. How to generate STUD pulses with large time-bandwidth products, how to measure their optical scattering signatures, and how to experimentally demonstrate their usefulness were explored. Theoretical and numerical studies were conducted on Stimulated Brillouin Scattering (SBS) and Crossed Beam Energy Transfer (CBET) including statistical models. We established how LPI can be tamed and gain democratized in space and time. Implementing STUD pulses on NIF was also studied. Future high rep rate lasers and fast diagnostics will aid in the adoption of the whole STUD pulse program for LPI control in High Energy Density Plasmas (HEDP).

  2. Nonlinear switching in multicore versus multimode waveguide junctions for mode-locked laser applications.

    Science.gov (United States)

    Nazemosadat, Elham; Mafi, Arash

    2013-12-16

    The main differences in nonlinear switching behavior between multicore versus multimode waveguide couplers are highlighted. By gradually decreasing the separation between the two cores of a dual-core waveguide and interpolating from a multicore to a multimode scenario, the role of the linear coupling, self-phase modulation, cross-phase modulation, and four-wave mixing terms are explored, and the key reasons are identified behind higher switching power requirements and lower switching quality in multimode nonlinear couplers.

  3. Diagnostics of hemangioma by the methods of correlation and fractal analysis of laser microscopic images of blood plasma

    Science.gov (United States)

    Boychuk, T. M.; Bodnar, B. M.; Vatamanesku, L. I.

    2012-01-01

    For the first time the complex correlation and fractal analysis was used for the investigation of microscopic images of both tissue images and hemangioma liquids. It was proposed a physical model of description of phase distributions formation of coherent radiation, which was transformed by optical anisotropic biological structures. The phase maps of laser radiation in the boundary diffraction zone were used as the main information parameter. The results of investigating the interrelation between the values of correlation (correlation area, asymmetry coefficient and autocorrelation function excess) and fractal (dispersion of logarithmic dependencies of power spectra) parameters are presented. They characterize the coordinate distributions of phase shifts in the points of laser images of histological sections of hemangioma, hemangioma blood smears and blood plasma with vascular system pathologies. The diagnostic criteria of hemangioma nascency are determined.

  4. Numerical simulations used for a validity check on the laser induced photo-detachment diagnostic method in electronegative plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Oudini, N. [Laboratoire des plasmas de décharges, Centre de Développement des Technologies Avancées, Cité du 20 Aout BP 17 Baba Hassen, 16081 Algiers (Algeria); Taccogna, F. [Istituto di Metodologie Inorganiche e dei Plasmi, CNR, via Amendola 122/D, 70126 Bari (Italy); Bendib, A. [Laboratoire d' Electronique Quantique, Faculté de Physique, USTHB, El Alia BP 32, Bab Ezzouar 16111, Algiers (Algeria); Aanesland, A. [Laboratoire de Physique des Plasmas (CNRS, Ecole Polytechnique, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud), École Polytechnique, 91128 Palaiseau Cedex (France)

    2014-06-15

    Laser photo-detachment is used as a method to measure or determine the negative ion density and temperature in electronegative plasmas. In essence, the method consists of producing an electropositive channel (negative ion free region) via pulsed laser photo-detachment within an electronegative plasma bulk. Electrostatic probes placed in this channel measure the change in the electron density. A second pulse might be used to track the negative ion recovery. From this, the negative ion density and temperature can be determined. We study the formation and relaxation of the electropositive channel via a two-dimensional Particle-In-Cell/Mote Carlo collision model. The simulation is mainly carried out in a Hydrogen plasma with an electronegativity of α = 1, with a parametric study for α up to 20. The temporal and spatial evolution of the plasma potential and the electron densities shows the formation of a double layer (DL) confining the photo-detached electrons within the electropositive channel. This DL evolves into two fronts that move in the opposite directions inside and outside of the laser spot region. As a consequence, within the laser spot region, the background and photo-detached electron energy distribution function relaxes/thermalizes via collisionless effects such as Fermi acceleration and Landau damping. Moreover, the simulations show that collisional effects and the DL electric field strength might play a non-negligible role in the negative ion recovery within the laser spot region, leading to a two-temperature negative ion distribution. The latter result might have important effects in the determination of the negative ion density and temperature from laser photo detachment diagnostic.

  5. A pilot study using laser-based technique for non-invasive diagnostics of hypertensive conditions in mice

    Science.gov (United States)

    Litvinova, Karina S.; Ahmad, Shakil; Wang, Keqing; Rafailov, Ilya E.; Sokolovski, Sergei G.; Zhang, Lin; Rafailov, Edik U.; Ahmed, Asif

    2016-02-01

    Endothelial dysfunction is directly linked to preeclampsia, a maternal hypertensive condition that is life threating for both the mother and the baby. Epidemiological studies show that women with a history of pre-eclampsia have an elevated risk for cardiovascular disease. Here we report a new non-invasive diagnostic test for preeclampsia in mice that allows us to non-invasively assess the condition of the animals during the experiment and treatment in established models of preeclampsia. A laser-based multifunctional diagnostics system (LAKK-M) was chosen to carry out non-invasive analysis of multiple parameters. The device was used to simultaneously record the microcirculatory blood flow and oxygen saturation, as well as fluorescence levels of endogenous fluorophores. Preliminary experiments were conducted on adenoviral (Ad-)- mediated overexpression of sFlt-1 (Ad-sFlt-1) to mimic preeclampsialike symptoms in mice. The recorded data displayed the ability of the LAKK-M diagnostics device to detect significant differences in perfusion measurements between the control and Ad-sFlt-1 treatment. Preliminary results provide a potential avenue to employ these diagnostics technology to monitor and aid in maintaining control of live animal conditions throughout the experiment and treatment.

  6. Real-time diagnostics of a jet engine exhaust using an intra-pulse quantum cascade laser spectrometer

    Science.gov (United States)

    Duxbury, Geoffrey; Hay, Kenneth G.; Langford, Nigel; Johnson, Mark P.; Black, John D.

    2011-09-01

    It has been demonstrated that an intra-pulse scanned quantum cascade laser spectrometer may be used to obtain real-time diagnostics of the amounts of carbon monoxide, carbon dioxide, and water, in the exhaust of an aero gas turbine (turbojet) engine operated in a sea level test cell. Measurements have been made of the rapid changes in composition following ignition, the composition under steady state operating conditions, and the composition changes across the exhaust plume. The minimum detection limit for CO in a double pass through a typical gas turbine plume of 50 cm in diameter, with 0.4 seconds integration time, is approximately 2 ppm.

  7. Surface properties of graphite and LaB6 materials used for laser heated emissive probe diagnostic

    Science.gov (United States)

    Mehta, P.; Sarma, A.; Sivagami, A. D.; HariPrakash, N.; Gopi, S.; Sarma, B.; Ghosh, J.

    2017-02-01

    Laser heated emissive probe (LHEP) has been used as an alternative diagnostics to measure direct plasma potential. In this case, surface properties of LHEP materials have been studied before and after exposing it to high power laser. A high density small diameter (0.5 mm) laser light of variable power density is used to heat the probe tip. Two types of probe tip material are used in this experiment, viz, Graphite (Coarse grain and HOPG) and LaB6. Purity of material is dependent on the constituents of the same. Surface properties of these materials before and after laser exposure and plasma conditions have been characterized by scanning electron microscopy (SEM) and the energy dispersive X-ray spectroscopy. In order to achieve higher sensitivity on carbon surface and other layers the low-energy probing ( 1.0 keV), the energy dispersive spectroscopy is used. Data of the energy dispersive X-ray spectroscopy allows us to obtain the structure of the materials as well as different elements present in these materials. To understand the surface morphology more critically, open source software named Gwyddion ( version 2.35) has been used for processing of the SEM images. The 3-D visualization of the probe tip at different experimental conditions has been made using the Interactive 3-D surface plot plug-in of Gwyddion. Optical properties are also analyzed using diffusion reflectance spectroscopy and from which band gap energy of the same has been estimated.

  8. Mode-locking of a high power, 888 nm pumped Nd:YVO4 laser using nonlinear polarization rotation via Type I second harmonic generation.

    Science.gov (United States)

    Schäfer, Christoph; Fries, Christian; Theobald, Christian; L'huillier, Johannes A

    2013-01-15

    Continuous-wave mode-locking of a laser exploiting the nonlinear polarization rotation (NPR) technique via Type I second harmonic generation is demonstrated for the first time. The NPR is generated by a lithium triborate crystal and transformed into nonlinear cavity losses of a 888 nm pumped Nd:YVO4 laser. Self-starting, reliable mode-locking has been achieved at a high average output power of 20.6 W and a pulse duration of 7.3 ps. Furthermore, transform limited pulses down to 2.7 ps have been demonstrated at 9.9 W.

  9. Time-Resolved Spectroscopy Diagnostic of Laser-Induced Optical Breakdown

    Directory of Open Access Journals (Sweden)

    Christian G. Parigger

    2010-01-01

    Full Text Available Transient laser plasma is generated in laser-induced optical breakdown (LIOB. Here we report experiments conducted with 10.6-micron CO2 laser radiation, and with 1.064-micron fundamental, 0.532-micron frequency-doubled, 0.355-micron frequency-tripled Nd:YAG laser radiation. Characterization of laser induced plasma utilizes laser-induced breakdown spectroscopy (LIBS techniques. Atomic hydrogen Balmer series emissions show electron number density of 1017 cm−3 measured approximately 10 μs and 1 μs after optical breakdown for CO2 and Nd:YAG laser radiation, respectively. Recorded molecular recombination emission spectra of CN and C2 Swan bands indicate an equilibrium temperature in excess of 7000 Kelvin, inferred for these diatomic molecules. Reported are also graphite ablation experiments where we use unfocused laser radiation that is favorable for observation of neutral C3 emission due to reduced C3 cation formation. Our analysis is based on computation of diatomic molecular spectra that includes accurate determination of rotational line strengths, or Hönl-London factors.

  10. Ultrasensitive nonlinear absorption response of large-size topological insulator and application in low-threshold bulk pulsed lasers.

    Science.gov (United States)

    Xu, Jin-Long; Sun, Yi-Jian; He, Jing-Liang; Wang, Yan; Zhu, Zhao-Jie; You, Zhen-Yu; Li, Jian-Fu; Chou, Mitch M C; Lee, Chao-Kuei; Tu, Chao-Yang

    2015-10-07

    Dirac-like topological insulators have attracted strong interest in optoelectronic application because of their unusual and startling properties. Here we report for the first time that the pure topological insulator Bi2Te3 exhibited a naturally ultrasensitive nonlinear absorption response to photoexcitation. The Bi2Te3 sheets with lateral size up to a few micrometers showed extremely low saturation absorption intensities of only 1.1 W/cm(2) at 1.0 and 1.3 μm, respectively. Benefiting from this sensitive response, a Q-switching pulsed laser was achieved in a 1.0 μm Nd:YVO4 laser where the threshold absorbed pump power was only 31 mW. This is the lowest threshold in Q-switched solid-state bulk lasers to the best of our knowledge. A pulse duration of 97 ns was observed with an average power of 26.1 mW. A Q-switched laser at 1.3 μm was also realized with a pulse duration as short as 93 ns. Moreover, the mode locking operation was demonstrated. These results strongly exhibit that Bi2Te3 is a promising optical device for constructing broadband, miniature and integrated high-energy pulsed laser systems with low power consumption. Our work clearly points out a significantly potential avenue for the development of two-dimensional-material-based broadband ultrasensitive photodetector and other optoelectronic devices.

  11. Nonlinear optical properties of near-infrared region Ag2S quantum dots pumped by nanosecond laser pulses

    OpenAIRE

    Li-wei Liu; Si-yi Hu; Yin-ping Dou; Tian-hang Liu; Jing-quan Lin; Yue Wang

    2015-01-01

    This study investigates near-infrared region Ag2S quantum dots (QDs) and their nonlinear optical response under 532 nm nanosecond laser pulses. Our experimental result shows that nonlinear transmission is reduced from 0.084 to 0.04. The observed narrowing behavior of the output pulse width shows superior optical limiting. We discuss the physical mechanisms responsible for the nonlinear optical response of the QDs. The average size of the nanocrystals was 5.5 nm. Our results suggest the possib...

  12. Laser patterning of nonlinear optical Bi2ZnB2O7 crystal lines in glass

    Directory of Open Access Journals (Sweden)

    Takayuki eKomatsu

    2015-05-01

    Full Text Available Bi2O3-based glasses are very attractive from the viewpoints of low-melting, high refractive index and crystallization, and the research on their glasses and glass-ceramics is at the frontiers of glass science and technology. Nonlinear optical Bi2ZnB2O7 crystal lines with a high orientation were patterned in 3Sm2O3-30.3Bi2O3-33.3ZnO-33.3B2O3 glass by using a laser-induced crystallization technique. It was confirmed from transmission electron microscope observations that crystals were formed in the inside of the glass, i.e., at the beneath of 4 micro-meter from the surface, although lasers (Yb:YVO4 laser with a wavelength of 1080 nm were focused at the glass surface. A new potential for optical device applications was added in Bi2O3-based glasses from the present study.

  13. The effect of a negatively chirped laser pulse on the evolution of bubble structure in nonlinear bubble regime

    Science.gov (United States)

    Vosoughian, H.; Riazi, Z.; Afarideh, H.; Sarri, G.

    2016-12-01

    In the nonlinear bubble regime, due to localized depletion at the front of the pulse during its propagation through the plasma, the phase shift between carrier waves and pulse envelope plays an important role in plasma response. The Carrier-Envelope Phase (CEP) breaks down the symmetric transverse ponderomotive force of the laser pulse that makes the bubble structure unstable. Our studies using a series of two-dimensional particle-in-cell simulations show that the utilization of a negatively chirped laser pulse is more effective in controlling the pulse depletion rate, and consequently, the effect of the CEP in the bubble regime. The results indicate that the pulse depletion rate diminishes during the propagation of the pulse in plasma that leads to postponing the effect of Carrier-Envelope Phase (CEP) in plasma response, and therefore, maintaining the stability of the bubble shape for a longer time than the un-chirped laser pulse. As a result, a localized electron bunch with higher maximum energy is produced during the acceleration process.

  14. Extreme and superextreme events in a loss-modulated CO2 laser: Nonlinear resonance route and precursors

    Science.gov (United States)

    Bonatto, Cristian; Endler, Antonio

    2017-07-01

    We investigate the occurrence of extreme and rare events, i.e., giant and rare light pulses, in a periodically modulated CO2 laser model. Due to nonlinear resonant processes, we show a scenario of interaction between chaotic bands of different orders, which may lead to the formation of extreme and rare events. We identify a crisis line in the modulation parameter space, and we show that, when the modulation amplitude increases, remaining in the vicinity of the crisis, some statistical properties of the laser pulses, such as the average and dispersion of amplitudes, do not change much, whereas the amplitude of extreme events grows enormously, giving rise to extreme events with much larger deviations than usually reported, with a significant probability of occurrence, i.e., with a long-tailed non-Gaussian distribution. We identify recurrent regular patterns, i.e., precursors, that anticipate the emergence of extreme and rare events, and we associate these regular patterns with unstable periodic orbits embedded in a chaotic attractor. We show that the precursors may or may not lead to the emergence of extreme events. Thus, we compute the probability of success or failure (false alarm) in the prediction of the extreme events, once a precursor is identified in the deterministic time series. We show that this probability depends on the accuracy with which the precursor is identified in the laser intensity time series.

  15. The use of nonlinear dynamics of erbium-doped fiber laser at pump modulation for intra-cavity sensing

    Science.gov (United States)

    Arellano-Sotelo, H.; Kir'yanov, A. V.; Barmenkov, Yu. O.; Aboites, V.

    2011-02-01

    We report the use of nonlinear dynamics of an erbium-doped fiber laser (EDFL) at pump modulation, namely the period-1 pulsed regime, for intra-cavity loss sensing and demonstrate noticeable sensitivity enhancement of an EDFL-based sensor, provided by this arrangement. Experimentally, we obtain a ten-fold increase of the sensor response, i.e. peak-to-peak pulse amplitude against loss variation, as compared with the standard sensing schemes using a low-power wide-spectrum light emitting diode (LED) or fiber laser without external modulation. This advantage originates from a strong dependence of pulse amplitude in the period-1 regime on intra-cavity loss variable that is, in turn, determined by the interrelation of relaxation frequency (an internal EDFL parameter) and frequency and depth of external (pump) modulation. A modeling of the EDFL-based sensor, presented for the case when the laser operates in the period-1 regime, allows an insight into the sensor operation details and opens the gate to its further optimization. The proposed sensing method seems to be a proper choice for the applications where an intra-cavity sensor's head has high internal loss (≥10 dB) while sensed loss is varied within a quite narrow range (a few dB).

  16. Nanoparticles for diagnostics and laser medical treatment of cartilage in orthopaedics

    Science.gov (United States)

    Baum, O. I.; Soshnikova, Yu. M.; Omelchenko, A. I.; Sobol, Emil

    2013-02-01

    Laser reconstruction of intervertebral disc (LRD) is a new technique which uses local, non-destructive laser irradiation for the controlled activation of regenerative processes in a targeted zone of damaged disc cartilage. Despite pronounced advancements of LRD, existing treatments may be substantially improved if laser radiation is absorbed near diseased and/or damaged regions in cartilage so that required thermomechanical stress and strain at chondrocytes may be generated and non-specific injury reduced or eliminated. The aims of the work are to study possibility to use nanoparticles (NPs) to provide spatial specificity for laser regeneration of cartilage. Two types of porcine joint cartilage have been impregnated with magnetite NPs: 1) fresh cartilage; 2) mechanically damaged cartilage. NPs distribution was studied using transition electron microscopy, dynamic light scattering and analytical ultracentrifugation techniques. Laser radiation and magnetic field have been applied to accelerate NPs impregnation. It was shown that NPs penetrate by diffusion into the mechanically damaged cartilage, but do not infiltrate healthy cartilage. Temperature dynamics in cartilage impregnated with NPs have been theoretically calculated and measurements using an IR thermo vision system have been performed. Laser-induced alterations of cartilage structure and cellular surviving have been studied for cartilage impregnated with NPs using histological and histochemical techniques. Results of our study suggest that magnetite NPs might be used to provide spatial specificity of laser regeneration. When damaged, the regions of cartilage impreganted with NPs have higher absorption of laser radiation than that for healthy areas. Regions containing NPs form target sites that can be used to generate laser-induced thermo mechanical stress leading to regeneration of cartilage of hyaline type.

  17. Nanosecond Square Pulse Fiber Laser based on the Nonlinear Amplifying Loop Mirror

    Institute of Scientific and Technical Information of China (English)

    陈国梁; 顾春; 许立新; 王安廷; 明海

    2011-01-01

    We propose and demonstrate a nanosecond square pulse ytterbium doped fiber laser in the 1060 nm band. The laser is based on the figure-8 structure and has a tunable pulse bandwidth from 3 ns to beyond 100 ns, showing excellent temporal tuning ability. The experimental results show that a steady square pulse can be generated when the parameters of the cavity are chosen appropriately.%We propose and demonstrate a nanosecond square pulse ytterbium doped fiber laser in the 1060nm band.The laser is based on the figure-8 structure and has a tunable pulse bandwidth from 3ns to beyond 100ns,showing excellent temporal tuning ability.The experimental results show that a steady square pulse can be generated when the parameters of the cavity are chosen appropriately.

  18. Non-linear photochemical pathways in laser induced atmospheric aerosol formation

    CERN Document Server

    Mongin, Denis; Schubert, Elise; Brisset, Jean-Gabriel; Berti, Nicolas; Moret, Michel; Prévôt, André S H; Baltensperger, Urs; Kasparian, Jérôme; Wolf, Jean-Pierre

    2015-01-01

    We measured the chemical composition and the size distribution of aerosols generated by femtosecond-Terawatt laser pulses in the atmosphere using an aerosol mass spectrometer (AMS). We show that nitric acid condenses in the form of ammonium nitrate, and that oxidized volatile organics also contribute to particle growth. These two components account for two thirds and one third, respectively, of the dry laser-condensed mass. They appear in two different modes centred at 380 nm and 150 nm. The number concentration of particles between 25 and 300 nm increases by a factor of 15. Pre-existing water droplets strongly increase the oxidative properties of the laser-activated atmosphere, substantially enhancing the condensation of organics under laser illumination.

  19. Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.

    Science.gov (United States)

    Rao, Harsha L; Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-03-01

    To evaluate the effect of typical scan score (TSS), when within the acceptable limits, on the diagnostic performance of retinal nerve fibre layer (RNFL) parameters with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in glaucoma. In a cross-sectional study, 203 eyes of 160 glaucoma patients and 140 eyes of 104 control subjects underwent RNFL imaging with the ECC protocol of SLP. TSS was used to quantify atypical birefringence pattern (ABP) images. Influence of TSS on the diagnostic ability of SLP parameters was evaluated by receiver operating characteristic (ROC) regression models after adjusting for the effect of disease severity [based on mean deviation (MD)] on standard automated perimetry). Diagnostic abilities of all RNFL parameters of SLP increased when the TSS values were higher. This effect was statistically significant for TSNIT (coefficient: 0.08, p<0.001) and inferior average parameters (coefficient: 0.06, p=0.002) but not for nerve fibre indicator (NFI, coefficient: 0.03, p=0.21). In early glaucoma (MD of -5 dB), predicted area under ROC curve (AUC) for TSNIT average parameter improved from 0.642 at a TSS of 90 to 0.845 at a TSS of 100. In advanced glaucoma (MD of -15 dB), AUC for TSNIT average improved from 0.832 at a TSS of 90 to 0.947 at 100. Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits. Diagnostic ability of NFI was unaffected by TSS values. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

    Science.gov (United States)

    deBoer, Gary; Scott, Carl

    2003-01-01

    Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal

  1. Complete description of polarization effects in the nonlinear Compton scattering. II. Linearly polarized laser photons

    CERN Document Server

    Ivanov, D Y; Serbo, V G

    2003-01-01

    We consider emission of a photon by an electron in the field of a strong laser wave. Polarization effects in this process are important for a number of physical problems. We discuss a probability of this process for linearly polarized laser photons and for arbitrary polarization of all other particles. We obtain the complete set of functions which describe such a probability in a compact form.

  2. High-energy fiber lasers at non-traditional colours, via intermodal nonlinearities

    DEFF Research Database (Denmark)

    Rishøj, Lars Søgaard; Chen, Y.; Steinvurzel, P.

    2012-01-01

    We propose exploiting intermodal four-wave mixing for energy-scalable tuneable fiber lasers, hitherto restricted to low powers, constrained by dispersion-tailoring limitations in PCFs. Conversion over an octave, at mJ-energy-levels, appears feasible.......We propose exploiting intermodal four-wave mixing for energy-scalable tuneable fiber lasers, hitherto restricted to low powers, constrained by dispersion-tailoring limitations in PCFs. Conversion over an octave, at mJ-energy-levels, appears feasible....

  3. Eight-channel Kirkpatrick-Baez microscope for multiframe x-ray imaging diagnostics in laser plasma experiments.

    Science.gov (United States)

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Mu, Baozhong; Wang, Zhanshan; Fang, Zhiheng; Wang, Wei; Fu, Sizu

    2016-10-01

    Because grazing-incidence Kirkpatrick-Baez (KB) microscopes have better resolution and collection efficiency than pinhole cameras, they have been widely used for x-ray imaging diagnostics of laser inertial confinement fusion. The assembly and adjustment of a multichannel KB microscope must meet stringent requirements for image resolution and reproducible alignment. In the present study, an eight-channel KB microscope was developed for diagnostics by imaging self-emission x-rays with a framing camera at the Shenguang-II Update (SGII-Update) laser facility. A consistent object field of view is ensured in the eight channels using an assembly method based on conical reference cones, which also allow the intervals between the eight images to be tuned to couple with the microstrips of the x-ray framing camera. The eight-channel KB microscope was adjusted via real-time x-ray imaging experiments in the laboratory. This paper describes the details of the eight-channel KB microscope, its optical and multilayer design, the assembly and alignment methods, and results of imaging in the laboratory and at the SGII-Update.

  4. Eight-channel Kirkpatrick-Baez microscope for multiframe x-ray imaging diagnostics in laser plasma experiments

    Science.gov (United States)

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Mu, Baozhong; Wang, Zhanshan; Fang, Zhiheng; Wang, Wei; Fu, Sizu

    2016-10-01

    Because grazing-incidence Kirkpatrick-Baez (KB) microscopes have better resolution and collection efficiency than pinhole cameras, they have been widely used for x-ray imaging diagnostics of laser inertial confinement fusion. The assembly and adjustment of a multichannel KB microscope must meet stringent requirements for image resolution and reproducible alignment. In the present study, an eight-channel KB microscope was developed for diagnostics by imaging self-emission x-rays with a framing camera at the Shenguang-II Update (SGII-Update) laser facility. A consistent object field of view is ensured in the eight channels using an assembly method based on conical reference cones, which also allow the intervals between the eight images to be tuned to couple with the microstrips of the x-ray framing camera. The eight-channel KB microscope was adjusted via real-time x-ray imaging experiments in the laboratory. This paper describes the details of the eight-channel KB microscope, its optical and multilayer design, the assembly and alignment methods, and results of imaging in the laboratory and at the SGII-Update.

  5. Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft x-ray free-electron laser

    Directory of Open Access Journals (Sweden)

    C. Behrens

    2012-03-01

    Full Text Available The successful operation of x-ray free-electron lasers (FELs, like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH, makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft x-ray pulse durations and electron bunch lengths at FLASH. The soft x-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft x-ray pulses with durations below 50 fs (FWHM after the implementation of the new uniform electron bunch compression scheme used at FLASH.

  6. Recent developments in the Thomson Parabola Spectrometer diagnostic for laser-driven multi-species ion sources

    Science.gov (United States)

    Alejo, A.; Gwynne, D.; Doria, D.; Ahmed, H.; Carroll, D. C.; Clarke, R. J.; Neely, D.; Scott, G. G.; Borghesi, M.; Kar, S.

    2016-10-01

    Ongoing developments in laser-driven ion acceleration warrant appropriate modifications to the standard Thomson Parabola Spectrometer (TPS) arrangement in order to match the diagnostic requirements associated to the particular and distinctive properties of laser-accelerated beams. Here we present an overview of recent developments by our group of the TPS diagnostic aimed to enhance the capability of diagnosing multi-species high-energy ion beams. In order to facilitate discrimination between ions with same Z/A, a recursive differential filtering technique was implemented at the TPS detector in order to allow only one of the overlapping ion species to reach the detector, across the entire energy range detectable by the TPS. In order to mitigate the issue of overlapping ion traces towards the higher energy part of the spectrum, an extended, trapezoidal electric plates design was envisaged, followed by its experimental demonstration. The design allows achieving high energy-resolution at high energies without sacrificing the lower energy part of the spectrum. Finally, a novel multi-pinhole TPS design is discussed, that would allow angularly resolved, complete spectral characterization of the high-energy, multi-species ion beams.

  7. Acoustic Diagnostics of Plasma Channels Induced by Intense Femtosecond Laser Pulses in Air

    Institute of Scientific and Technical Information of China (English)

    HAO Zuo-Qiang; WEI Zhi-Yi; YU Jin; ZHANG Jie; LI Yu-Tong; YUAN Xiao-Hui; ZHENG Zhi-Yuan; WANG Peng; WANG Zhao-Hua; LING Wei-Jun

    2005-01-01

    @@ Long plasma channels induced by femtosecond laser pulses in air are diagnosed using the sonographic method. By detecting the sound signals along the channels, the length and the electron density of the channels are measured.

  8. Non-linear swept frequency technique for CO2 measurements using a CW laser system

    CERN Document Server

    Campbell, Joel F

    2013-01-01

    A system using a non-linear multi-swept sine wave system is described which employs a multi-channel, multi-swept orthogonal waves, to separate channels and make multiple, simultaneous online/offline CO2 measurements. An analytic expression and systematic method for determining the orthogonal frequencies for the unswept, linear swept and non-linear swept cases is presented. It is shown that one may reduce sidelobes of the autocorrelation function while preserving cross channel orthogonality, for thin cloud rejection.

  9. Statistical and fractal approaches in laser polarimetry diagnostics of the cancer prostate tissues

    Science.gov (United States)

    Ushenko, Alexander; Yermolenko, Sergej; Prydij, Alexander; Guminetsky, Stepan; Gruia, Ion; Toma, Ovidiu; Vladychenko, Konstantin

    2008-05-01

    This work is directed to the investigation of the scope of the technique of laser polarimetry of oncological changes of the human prostate tissue under the conditions of multiple scattering, which presents a more general and real experimental clinical situation. To compare the above mentioned scope of biotissue laser polarimetry on the first stage the research of human prostate tissue in the conditions of single scattering was performed.

  10. Generating multi-GeV electron bunches using single stage laser wakefield acceleration in a 3D nonlinear regime

    Directory of Open Access Journals (Sweden)

    W. Lu

    2007-06-01

    Full Text Available The extraordinary ability of space-charge waves in plasmas to accelerate charged particles at gradients that are orders of magnitude greater than in current accelerators has been well documented. We develop a phenomenological framework for laser wakefield acceleration (LWFA in the 3D nonlinear regime, in which the plasma electrons are expelled by the radiation pressure of a short pulse laser, leading to nearly complete blowout. Our theory provides a recipe for designing a LWFA for given laser and plasma parameters and estimates the number and the energy of the accelerated electrons whether self-injected or externally injected. These formulas apply for self-guided as well as externally guided pulses (e.g. by plasma channels. We demonstrate our results by presenting a sample particle-in-cell (PIC simulation of a 30   fs, 200 TW laser interacting with a 0.75 cm long plasma with density 1.5×10^{18}  cm^{-3} to produce an ultrashort (10 fs monoenergetic bunch of self-injected electrons at 1.5 GeV with 0.3 nC of charge. For future higher-energy accelerator applications, we propose a parameter space, which is distinct from that described by Gordienko and Pukhov [Phys. Plasmas 12, 043109 (2005PHPAEN1070-664X10.1063/1.1884126] in that it involves lower plasma densities and wider spot sizes while keeping the intensity relatively constant. We find that this helps increase the output electron beam energy while keeping the efficiency high.

  11. Mode-locked femtosecond all polarization-maintaining erbium-doped dispersion managed fiber laser based on a nonlinear amplifying loop mirror

    Science.gov (United States)

    Wu, Wenjue; Zhou, Yue; Sun, Ji; Dai, Yitang; Yin, Feifei; Dai, Jian; Xu, Kun

    2016-11-01

    We proposed a mode-locked all-polarization-maintaining erbium-doped fiber laser base on a nonlinear amplifying loop mirror (NALM). The laser can generate 1.6 ps pulses at 1550 nm with the energy of 1 nJ that can be compressed down to 100 fs with the compressor outside the cavity. The repetition rate of the output pulse is 12MHz. Such configuration of laser is easier controlled and self starting long term operation, and is highly desirable for industrial applications, such as micro-machining.

  12. Double lens device for tunable harmonic generation of laser beams in KBBF/RBBF crystals or other non-linear optic materials

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Adam

    2017-08-22

    A method and apparatus to generate harmonically related laser wavelengths includes a pair of lenses at opposing faces of a non-linear optical material. The lenses are configured to promote incoming and outgoing beams to be normal to each outer lens surface over a range of acceptance angles of the incoming laser beam. This reduces reflection loss for higher efficiency operation. Additionally, the lenses allow a wider range of wavelengths for lasers for more universal application. Examples of the lenses include plano-cylindrical and plano-spherical form factors.

  13. Low-Complexity Tracking of Laser and Nonlinear Phase Noise in WDM Optical Fiber Systems

    DEFF Research Database (Denmark)

    Yankov, Metodi Plamenov; Fehenberger, Tobias; Barletta, Luca;

    2015-01-01

    In this paper, the wavelength division multiplexed (WDM) fiber optic channel is considered. It is shown that for ideal distributed Raman amplification (IDRA), the Wiener process model is suitable for the non-linear phase noise due to cross phase modulation from neighboring channels. Based...

  14. An iterative method for the computation of nonlinear, wide-angle, pulsed acoustic fields of medical diagnostic transducers

    NARCIS (Netherlands)

    Huijssen, J.; Verweij, M.D.

    2010-01-01

    The development and optimization of medical ultrasound transducers and imaging modalities require a computational method that accurately predicts the nonlinear acoustic pressure field. A prospective method should provide the wide-angle, pulsed field emitted by an arbitrary planar source distribution

  15. Traveling Wave Evolutions of a Cosh-Gaussian Laser Beam in Both Kerr and Cubic Quintic Nonlinear Media Based on Mathematica

    Institute of Scientific and Technical Information of China (English)

    WANG Jun-Min

    2011-01-01

    With the aid of Mathematica, three auxiliary equations, i.e.the Riccati equation, the Lenard equation and the Hyperbolic equation, are employed to investigate traveling wave solutions of a cosh-Gaussian laser beam in both Kerr and cubic quintic nonlinear media. As a result, many traveling wave solutions are obtained, including soliton-like solutions, hyperbolic function solutions and trigonometric function solutions.

  16. Experimental demonstration of tunable homodyne detection of WDM and dual-polarization PSK channels by automatically locking the channels to a local pump laser using nonlinear mixing.

    Science.gov (United States)

    Almaiman, Ahmed; Ziyadi, Morteza; Mohajerin-Ariaei, Amirhossein; Cao, Yinwen; Chitgarha, Mohammad Reza; Liao, Peicheng; Bao, Changjing; Shamee, Bishara; Ahmed, Nisar; Alishahi, Fatemeh; Fallahpour, Ahmad; Akasaka, Youichi; Yang, Jeng-Yuan; Sekiya, Motoyoshi; Touch, Joseph D; Tur, Moshe; Langrock, Carsten; Fejer, Martin M; Willner, Alan E

    2016-06-15

    This Letter proposes a method for tunable automatically locked homodyne detection of wavelength-division multiplexing (WDM) dual-polarization (DP) phase-shift keyed (PSK) channels using nonlinear mixing. Two stages of periodically poled lithium niobate (PPLN) waveguides and an LCoS filter enable automatic phase locking of the channels to a local laser.

  17. Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, A. P., E-mail: APKuznetsov@mephi.ru [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) (Russian Federation); Buzinskij, O. I. [State Research Center Troitsk Institute for Innovation and Fusion Research (TRINITI) (Russian Federation); Gubsky, K. L.; Nikitina, E. A.; Savchenkov, A. V.; Tarasov, B. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) (Russian Federation); Tugarinov, S. N. [State Research Center Troitsk Institute for Innovation and Fusion Research (TRINITI) (Russian Federation)

    2015-12-15

    A set of optical diagnostics is expected for measuring the plasma characteristics in ITER. Optical elements located inside discharge chambers are exposed to an intense radiation load, sputtering due to collisions with energetic atoms formed in the charge transfer processes, and contamination due to recondensation of materials sputtered from different parts of the construction of the chamber. Removing the films of the sputtered materials from the mirrors with the aid of pulsed laser radiation is an efficient cleaning method enabling recovery of the optical properties of the mirrors. In this work, we studied the efficiency of removal of metal oxide films by pulsed radiation of a fiber laser. Optimization of the laser cleaning conditions was carried out on samples representing metal substrates polished with optical quality with deposition of films on them imitating the chemical composition and conditions expected in ITER. It is shown that, by a proper selection of modes of radiation exposure to the surface with a deposited film, it is feasible to restore the original high reflection characteristics of optical elements.

  18. Nonlinear Absorption-Gain Response and Population Dynamics in a Laser-Driven Four-Level Dense Atomic System

    Institute of Scientific and Technical Information of China (English)

    LI Jia-Hua; LIU Ji-Bing; LUO Jin-Ming; XIE Xiao-Tao

    2006-01-01

    We theoretically investigate the response of nonlinear absorption and population dynamics in optically dense media of four-level atoms driven by a single-mode probe laser, via taking the density-dependent near dipoledipole (NDD) interactions into consideration. The influence of the NDD effects on the absorption of the probe field and population dynamics is predicted via numerical calculations. It is shown that the NDD effects can reduce gradually to transient absorption with the increase of the strengths of the NDD interactions, and transient amplification can be achieved. In the steady-state limit, the probe field exhibits transparency for strong NDD interactions. Alternatively, the population entirely remains at the ground state due to the NDD effects.

  19. Nonlinear automatic landing control of unmanned aerial vehicles on moving platforms via a 3D laser radar

    Science.gov (United States)

    Hervas, Jaime Rubio; Reyhanoglu, Mahmut; Tang, Hui

    2014-12-01

    This paper presents a motion tracking and control system for automatically landing Unmanned Aerial Vehicles (UAVs) on an oscillating platform using Laser Radar (LADAR) observations. The system itself is assumed to be mounted on a ship deck. A full nonlinear mathematical model is first introduced for the UAV. The ship motion is characterized by a Fourier transform based method which includes a realistic characterization of the sea waves. LADAR observation models are introduced and an algorithm to process those observations for yielding the relative state between the vessel and the UAV is presented, from which the UAV's state relative to an inertial frame can be obtained and used for feedback purposes. A sliding mode control algorithm is derived for tracking a landing trajectory defined by a set of desired waypoints. An extended Kalman filter (EKF) is proposed to account for process and observation noises in the design of a state estimator. The effectiveness of the control algorithm is illustrated through a simulation example.

  20. Rational harmonic mode-locked laser using a bismuth-oxide-based highly nonlinear erbium-doped fiber

    Science.gov (United States)

    Fukuchi, Yutaka; Hirata, Kouji; Muraguchi, Masahiro; Maeda, Joji

    2017-01-01

    We report a rational harmonic mode-locked fiber laser employing a bismuth-oxide-based highly nonlinear erbium-doped fiber (Bi-HNL-EDF) with a length of 1.5 m. The Bi-HNL-EDF is used as a broadband gain medium and as a noise suppressor based on self-phase modulation. The amplitude of the rational harmonic mode-locked pulses can be regulated by properly tuning the modulation parameters of the intracavity modulator. The cavity length as short as 6 m enables generation of stable and clean short pulses with a repetition frequency up to 40 GHz over the wavelength range covering both the conventional and the longer bands.

  1. Plasma diagnostics from self-absorbed doublet lines in laser-induced breakdown spectroscopy

    Science.gov (United States)

    D'Angelo, C. A.; Garcimuño, M.; Díaz Pace, D. M.; Bertuccelli, G.

    2015-10-01

    In this paper, a generalized approach is developed and applied for plasma characterization and quantitative purposes in laser-induced breakdown spectroscopy (LIBS) experiences by employing a selected pair of spectral lines belonging to the same multiplet. It is based on the comparison between experimental ratios of line parameters and the theoretical calculus obtained under the framework of a homogeneous plasma in local thermodynamic equilibrium. The applicability of the method was illustrated by using the atomic resonance transitions 279.55-280.27 nm of Mg II, which are usually detected in laser-induced plasma (LIP) during laser ablation of many kinds of targets. The laser induced plasmas were produced using a Nd:YAG laser from a pressed pellet of powdered calcium hydroxide with a concentration of 300 ppm of Mg. The experimental ratios for peak intensities, total intensities and Stark widths were obtained for different time windows and matched to the theoretical calculus. The temperature and the electron density of the plasma, as well as the Mg columnar density (the atom/ion concentration times the length of the plasma along the line-of-sight), were determined. The results were interpreted under the employed approach.

  2. High resolution X-ray spherically bent crystal spectrometer for laser-produced plasma diagnostics

    Institute of Scientific and Technical Information of China (English)

    Shali Xiao; Hongjian Wang; Jun Shi; Changhuan Tang; Shenye Liu

    2009-01-01

    A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5 - 0.9 nm range. A large open aperture (30 x 20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 x 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laser produced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/鈻矱 ~ 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.

  3. Non-Linear Compton Scattering of Ultrashort and Ultraintense Laser Pulses

    CERN Document Server

    Seipt, D

    2010-01-01

    The scattering of temporally shaped intense laser pulses off electrons is discussed by means of manifestly covariant quantum electrodynamics. We employ a framework based on Volkov states with a time dependent laser envelope in light-cone coordinates within the Furry picture. An expression for the cross section is constructed, which is independent of the considered pulse shape and pulse length. A broad distribution of scatted photons with a rich pattern of subpeaks like that obtained in Thomson scattering is found. These broad peaks may overlap at sufficiently high laser intensity, rendering inappropriate the notion of individual harmonics. The limit of monochromatic plane waves as well as the classical limit of Thomson scattering are discussed. As a main result, a scaling law is presented connecting the Thomson limit with the general result for arbitrary kinematics. In the overlapping regions of the spectral density, the classical and quantum calculations give different results, even in the Thomson limit. Thu...

  4. Laser diagnodent: a comparative study with other diagnostic techniques; Laser diagnodent: estudo comparativo com outras tecnicas de diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, Reugma Rego

    2002-07-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  5. Diode pumped solid state kilohertz disk laser system for time-resolved combustion diagnostics under microgravity at the drop tower Bremen

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Volker; Paa, Wolfgang; Triebel, Wolfgang [Institute of Photonic Technology, Laser Diagnostics, Albert-Einstein-Str. 9, 07745 Jena (Germany); Eigenbrod, Christian; Klinkov, Konstantin [Center of Applied Space Technology and Microgravity, University Bremen, Am Fallturm, 28359 Bremen (Germany); Larionov, Mikhail; Giesen, Adolf; Stolzenburg, Christian [Institut für Strahlwerkzeuge (IFSW), Pfaffenwaldring 43, 70569 Stuttgart (Germany)

    2014-03-15

    We describe a specially designed diode pumped solid state laser system based on the disk laser architecture for combustion diagnostics under microgravity (μg) conditions at the drop tower in Bremen. The two-stage oscillator-amplifier-system provides an excellent beam profile (TEM{sub 00}) at narrowband operation (Δλ < 1 pm) and is tunable from 1018 nm to 1052 nm. The laser repetition rate of up to 4 kHz at pulse durations of 10 ns enables the tracking of processes on a millisecond time scale. Depending on the specific issue it is possible to convert the output radiation up to the fourth harmonic around 257 nm. The very compact laser system is integrated in a slightly modified drop capsule and withstands decelerations of up to 50 g (>11 ms). At first the concept of the two-stage disk laser is briefly explained, followed by a detailed description of the disk laser adaption to the drop tower requirements with special focus on the intended use under μg conditions. In order to demonstrate the capabilities of the capsule laser as a tool for μg combustion diagnostics, we finally present an investigation of the precursor-reactions before the droplet ignition using 2D imaging of the Laser Induced Fluorescence of formaldehyde.

  6. A 7.81 W 355 nm ultraviolet picosecond laser using La2CaB10O19 as a nonlinear optical crystal.

    Science.gov (United States)

    Zhang, Ling; Li, Kai; Xu, Degang; Yu, Haijuan; Zhang, Guochun; Wang, Yuye; Wang, Lirong; Shan, Faxian; Yan, Chao; Yang, Yingying; Wang, Baohua; Wang, Nan; Lin, Xuechun; Wu, Yicheng; Yao, Jianquan

    2014-07-14

    We demonstrate high-power 355 nm ultraviolet (UV) picosecond (ps) laser using a type I phase-matching nonlinear optical crystal of La(2)CaB(10)O(19) (LCB), which possesses the characteristic of non-hygroscopicity. The high-power third harmonic generation was successfully achieved from two types of 1064 nm ps fundamental lasers. The maximum output power of 7.81 W of 355 nm UV laser was obtained with a pump of 35.2 W 1064 nm ps laser (80 MHz repetition rate, 10 ps pulse width) with optical conversion efficiency of 22.2%. The experimental results show that the LCB crystal is a promising candidate for generating high-power UV laser.

  7. Complete description of polarization effects in the nonlinear Compton scattering. I. Circularly polarized laser photons

    CERN Document Server

    Ivanov, D Y; Serbo, V G

    2003-01-01

    We consider emission of a photon by an electron in the field of a strong laser wave. Polarization effects in this process are important for a number of physical problems. We discuss a probability of this process for circularly polarized laser photons and for arbitrary polarization of all other particles. We obtain the complete set of functions which describe such a probability in a compact covariant form. Besides, we discuss an application of the obtained formulas to the problem of electron -> photon conversion at photon-photon and photon-electron colliders.

  8. Effect of nonlinearity in the pass-through optics on femtosecond laser filament in air

    CERN Document Server

    Dergachev, Alexander A; Kandidov, Valery P; Mokrousova, Daria V; Seleznev, Leonid V; Sinitsyn, Dmitry V; Sunchugasheva, Elena S; Shlenov, Svyatoslav A; Shustikova, Anna P

    2014-01-01

    An influence of pass-through optics on femtosecond laser pulse filamentation in ambient air is analyzed for the first time both experimentally and numerically. Propagation of high-power femtosecond laser pulse through solid optical elements introduces spatiotemporal phase modulation due to the Kerr effect. This modulation may have a strong ef-fect on the pulse filamentation in air. We demonstrated that the phase modulation obtained in the thin pass-through dielectric plate reduces the distance to the filament onset and increases the plasma channel length

  9. Dynamical Phenomena in an Optical-Wavelength Phonon Laser (Phaser): Nonlinear Resonances and Self-Organized Mode Alternation

    CERN Document Server

    Makovetskii, D N

    2011-01-01

    This is a part of an overview of my early studies on nonlinear spin-phonon dynamics in solid state optical-wavelength phonon lasers (phasers) started in 1984. The main goal of this work is a short description and a qualitative analysis of experimental data on low-frequency nonlinear resonances revealed in a nonautonomous ruby phaser. Under phaser pumping modulation near these resonances, an unusual kind of self-organized motions in the ruby spin-phonon system was observed by me in 1984 for the first time. The original technique of optical-wavelength microwave-frequency acoustic stimulated emission (SE) detection and microwave-frequency power spectra (MFPS) analysis was used in these experiments (description of the technique see: D.N.Makovetskii, Cand. Sci. Diss., Kharkov, 1983). The real time evolution of MFPS was studied using this technique at scales up to several hours. The phenomenon of the self-organized periodic alternation of SE phonon modes was experimentally revealed at hyperlow frequencies from abou...

  10. Nonlinear and spin effects in two-photon annihilation of a fermion pair in an intensive laser wave

    CERN Document Server

    Sikach, S M

    2001-01-01

    The pattern of calculation of amplitudes of a series of processes in the field of an intensive laser wave, in which two fermions $(p; p')$ and two real photons $(k_1; k_2)$ participate, is considered. In relation to one-photon processes, these processes are of the second order on $\\alpha$, if the wave intensity $\\xi \\ll 1$ (i.e., actually absorption from the wave only one quantum). Otherwise, they are competing and essentially nonlinear. One-photon processes have a number of the important physical applications. For example, ${\\gamma}e$ and ${\\gamma}{\\gamma}$ colliders work on their basis. In DSB the calculation is conducted at the level of reaction amplitudes. It essentially simplifies both the calculation and the form of obtained results; those combinations of amplitudes which describe the spin effects are easy to calculate. And these effects are especially essential in nonlinear processes. The calculations are conducted in covariant form. Besides compactness, this provides independence of the frames of refe...

  11. Application of a Schlieren diagnostic to the behavior of exploding bridge wire and laser detonators

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Michael J [Los Alamos National Laboratory; Clarke, Steven A [Los Alamos National Laboratory; Munger, Alan C [Los Alamos National Laboratory; Thomas, Keith A [Los Alamos National Laboratory

    2009-01-01

    Even though the exploding bridge wire (EBW) detonator has been in use for over 60 years, there are still discussions about the mechanism for achieving detonation. Los Alamos has been developing a high-power laser detonator to function in a manner similar to an EBW. Schlieren imaging techniques are applied to laser-driven detonator output in polydimethylsiloxane (POMS) samples to investigate the time-dependent geometry of the shock wave and to obtain instantaneous measurements of shock-front velocity. Velocity Hugoniot data are used to convert measured shock velocities to corresponding particle velocities, allowing instantaneous shock pressures to be obtained via Rankine-Hugoniot relations across the shock.

  12. Full 3D modelling of pulse propagation enables efficient nonlinear frequency conversion with low energy laser pulses in a single-element tripler

    Science.gov (United States)

    Kardaś, Tomasz M.; Nejbauer, Michał; Wnuk, Paweł; Resan, Bojan; Radzewicz, Czesław; Wasylczyk, Piotr

    2017-01-01

    Although new optical materials continue to open up access to more and more wavelength bands where femtosecond laser pulses can be generated, light frequency conversion techniques are still indispensable in filling the gaps on the ultrafast spectral scale. With high repetition rate, low pulse energy laser sources (oscillators) tight focusing is necessary for a robust wave mixing and the efficiency of broadband nonlinear conversion is limited by diffraction as well as spatial and temporal walk-off. Here we demonstrate a miniature third harmonic generator (tripler) with conversion efficiency exceeding 30%, producing 246 fs UV pulses via cascaded second order processes within a single laser beam focus. Designing this highly efficient and ultra compact frequency converter was made possible by full 3-dimentional modelling of propagation of tightly focused, broadband light fields in nonlinear and birefringent media. PMID:28225007

  13. Full 3D modelling of pulse propagation enables efficient nonlinear frequency conversion with low energy laser pulses in a single-element tripler.

    Science.gov (United States)

    Kardaś, Tomasz M; Nejbauer, Michał; Wnuk, Paweł; Resan, Bojan; Radzewicz, Czesław; Wasylczyk, Piotr

    2017-02-22

    Although new optical materials continue to open up access to more and more wavelength bands where femtosecond laser pulses can be generated, light frequency conversion techniques are still indispensable in filling the gaps on the ultrafast spectral scale. With high repetition rate, low pulse energy laser sources (oscillators) tight focusing is necessary for a robust wave mixing and the efficiency of broadband nonlinear conversion is limited by diffraction as well as spatial and temporal walk-off. Here we demonstrate a miniature third harmonic generator (tripler) with conversion efficiency exceeding 30%, producing 246 fs UV pulses via cascaded second order processes within a single laser beam focus. Designing this highly efficient and ultra compact frequency converter was made possible by full 3-dimentional modelling of propagation of tightly focused, broadband light fields in nonlinear and birefringent media.

  14. Extreme Nonlinear Optics of High Intensity Laser Pulse Filamentation in Gases

    Science.gov (United States)

    2016-05-12

    applicable. On classified documents, enter the title classification in parentheses. 5a. CONTRACT NUMBER. Enter all contract numbers as they appear...accordance with security classification regulations, e.g. U, C, S, etc. If this form contains classified information, stamp classification level on...our diagnostics ( spectral interferometry) used for these measurements enabled absolute measurements of the instantaneous and rovibrational

  15. Femtosecond-Laser Patterning of Polymers: Nonlinear and Negative Index Devices

    Science.gov (United States)

    2011-01-20

    photonics, it is a technology that creates new markets for the laser industry and enables innovative applications. doi:10.1038/nphoton.2008.48 References 1... microenvironment of living tissues with respect to dimensionality, architecture and cell polarity. Unlike cells migrating in 2D, cells in 3D need to

  16. Experimental mapping of nonlinear dynamics in synchronized coupled semiconductor laser networks

    Science.gov (United States)

    Argyris, Apostolos; Bourmpos, Michail; Syvridis, Dimitris

    2015-05-01

    The potential of conventional semiconductor lasers to generate complex and chaotic dynamics at a bandwidth that extends up to tens of GHz turns them into useful components in applications oriented to sensing and security. Specifically, latest theoretical and experimental works have demonstrated the capability of mutually coupled semiconductor lasers to exhibit a joint behaviour under various conditions. In an uncoupled network consisting of N similar SLs - representing autonomous nodes in the network - each node emits an optical signal of various dynamics depending on its biasing conditions and internal properties. These nodes remain unsynchronized unless appropriate coupling and biasing conditions apply. A synchronized behaviour can be in principle observed in sub-groups of lasers or in the overall laser network. In the present work, experimental topologies that employ eight SLs, under diverse biasing and coupling conditions, are built and investigated. The deployed systems incorporate off-the-shelf fiber-optic communications components operating at the 1550nm spectral window. The role of emission wavelength detuning of each participating node in the network - at GHz level - is evaluated.

  17. Ln3GaS6 (Ln = Dy, Y): new infrared nonlinear optical materials with high laser induced damage thresholds.

    Science.gov (United States)

    Zhang, Ming-Jian; Li, Bing-Xuan; Liu, Bin-Wen; Fan, Yu-Hang; Li, Xiao-Guo; Zeng, Hi-Yi; Guo, Guo-Cong

    2013-10-21

    Two new ternary rare earth chalcogenides, Dy3GaS6 (1) and Y3GaS6 (2), are reported here. They both crystallize in the orthorhombic space group Cmc21 (no. 36). Both are synthesized in pure phase and show phase-matchable second harmonic generation (SHG) of about 0.2 and 0.5 times, respectively for 1 and 2, as strong as that of KTiOPO4 (KTP) based on the powder SHG measurement at the wavelength of 1910 nm. They possess high powder laser induced damage thresholds (LIDTs), respectively, about 14 and 18 times that of AgGaS2 (AGS) based on the powder LIDT measurements under 1064 nm laser irradiation. They both exhibit wide transparency in the IR region (2.5–25 μm). It is believed that the title compounds are new candidates for nonlinear optical (NLO) materials in the IR region. To gain further insights into the NLO and LIDT properties of 1 and 2, the calculations of second-order NLO susceptibility and lattice energy density (LED) were also performed to explain their SHG efficiencies and high LIDTs.

  18. Pulse bundles and passive harmonic mode-locked pulses in Tm-doped fiber laser based on nonlinear polarization rotation.

    Science.gov (United States)

    Wang, Xiong; Zhou, Pu; Wang, Xiaolin; Xiao, Hu; Liu, Zejin

    2014-03-10

    We demonstrate the nanosecond-level pulses in Tm-doped fiber laser generated by passively harmonic mode-locking. Nonlinear polarization rotation performed by two polarization controllers (PCs) is employed to induce the self-starting harmonic mode-locking. The fundamental repetition rate of the laser is 448.8 kHz, decided by the length of the cavity. Bundles of pulses with up to 17 uniform subpulses are generated due to the split of pulse when the pump power increases and the PCs are adjusted. Continuous harmonic mode-locked pulse trains are obtained with 1st to 6th and even more than 15th order when the positions of the PCs are properly fixed and the pump power is scaled up. The widths of all the uniform individual pulses are mostly 3-5 ns, and pulse with width of 304 ns at fundamental repetition rate can also be generated by adjusting the PCs. Hysteresis phenomenon of the passively harmonic mode-locked pulses' repetition frequency versus pump power is observed. The rather wide 3dB spectral bandwidth of the pulse train (25 nm) indicates that they may resemble noise-like pulses.

  19. Diagnostic probes for particle and molecule distributions in laser-generated plumes

    Energy Technology Data Exchange (ETDEWEB)

    Kimbrell, S.M.

    1990-10-17

    Laser microprobe analysis (LMA) offers good spatial and depth resolution for solid sampling of virtually any material. Coupled with numerous optical spectroscopic and mass spectrometric detection methods, LMA is a powerful analytical tool. Yet, fundamental understanding of the interaction between the laser and the sample surface leading to the formation of the high temperature plasma (plume) is far from complete. To better understand the process of plume formation, an imaging method based on acousto-optic laser beam deflection has been coupled with light scattering methods and absorption methods to record temporal and spatial maps of the particle and molecule distributions in the plume with good resolution. Because particles can make up a major fraction of the vaporized material under certain operating conditions, they can reflect a large loss of atomic signal for elemental analysis, even when using auxiliary excitation to further vaporized the particles. Characterization of the particle size distributions in plumes should provide insight into the vaporization process and information necessary for studies of efficient particle transfer. Light scattering methods for particle size analysis based on the Mie Theory are used to determine the size of particles in single laser-generated plumes. The methods used, polarization ratio method and dissymmetry ratio method, provide good estimates of particle size with good spatial and temporal resolution for this highly transient system. Large particles, on the order of 0.02-0.2{mu}m in radius, were observed arising directly from the sample surface and from condensation.

  20. Pitchfork Bifurcation and Zharov Splitting in Nonlinear Mid-infrared Photothermal Spectroscopy in a liquid crystal using a Quantum Cascade Laser

    CERN Document Server

    Mertiri, Alket; Hong, M K; Mehta, P; Mertz, J; Ziegler, L D; Erramilli, Shyamsunder

    2013-01-01

    We report on the mid-infrared nonlinear photothermal spectrum of the neat liquid crystal 4-Octyl-4'-Cyanobiphenyl (8CB) using a tunable Quantum Cascade Laser (QCL). The nonequilibrium steady state characterized by the nonlinear photothermal infrared response undergoes a supercritical pitchfork bifurcation. The bifurcation, observed in heterodyne two-color pump-probe detection, leads to ultrasharp nonlinear infrared spectra similar to those reported in the visible region. A systematic study of the peak splitting as function of absorbed infrared power shows the bifurcation has a critical exponent of 0.5. The surprising observation of an apparently universal critical exponent in a nonequilibrium state is explained using a simple model reminiscent of mean field theory. Apart from the intrinsic interest for nonequilibrium studies, nonlinear photothermal methods lead to a dramatic narrowing of spectral lines, giving rise to a potential new contrast mechanism for the rapidly emerging new field of mid-infrared micros...

  1. Diagnostics improvement in the ABC facility and preliminary tests on laser interaction with light-atom clusters and p+{sup 11}B targets

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, Fabrizio, E-mail: fabrizio.consoli@enea.it [Associazione Euratom - ENEA sulla Fusione, via E. Fermi 45, CP 65-00044 Frascati, Rome (Italy); De Angelis, Riccardo; Andreoli, Pierluigi; Cristofari, Giuseppe; Di Giorgio, Giorgio [Associazione Euratom - ENEA sulla Fusione, via E. Fermi 45, CP 65-00044 Frascati, Rome (Italy); Bonasera, Aldo [INFN - LNS, via S. Sofia 62, I-95123 Catania (Italy); Cyclotron Institute, Texas A and M University, College Station, TX, 77843 (United States); Barbui, Marina [Cyclotron Institute, Texas A and M University, College Station, TX, 77843 (United States); Mazzocco, Marco [Dipartimento di Fisica G. Galilei, Università degli Studi di Padova, via F. Marzolo 8, I-35131 Padova (Italy); Bang, Woosuk; Dyer, Gilliss; Quevedo, Hernan [Texas Center for High Intensity Laser Science, University of Texas at Austin, Austin 78712, TX (United States); Hagel, Kris; Schmidt, Katarzyna [Cyclotron Institute, Texas A and M University, College Station, TX, 77843 (United States); Gaul, Erhard; Borger, Ted; Bernstein, Aaron; Martinez, Mikael; Donovan, Michael [Texas Center for High Intensity Laser Science, University of Texas at Austin, Austin 78712, TX (United States); Barbarino, Matteo [Cyclotron Institute, Texas A and M University, College Station, TX, 77843 (United States); Kimura, Sachie [INFN - LNS, via S. Sofia 62, I-95123 Catania (Italy); and others

    2013-08-21

    The diagnostics of particle flows in Inertial Confinement Fusion experiments is a delicate issue, due to the fast timescales and to the strong radiative electromagnetic contributions. This makes the discrimination of the different particles produced by the laser–plasma interaction not trivial, and requires the use of several diagnostic techniques. We describe here the diagnostics improvement in the ABC facility. They will provide more detailed analysis of microwave fields and particles originating from the interaction of laser with targets foreseen for future experiments.

  2. Synchronization and Characterization of an Ultra-Short Laser for Photoemission and Electron-Beam Diagnostics Studies at a Radio Frequency Photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Timothy; Ruan, Jinhao; Piot, Philippe; Lumpkin, Alex

    2012-03-01

    A commercially-available titanium-sapphire laser system has recently been installed at the Fermilab A0 photoinjector laboratory in support of photoemission and electron beam diagnostics studies. The laser system is synchronized to both the 1.3-GHz master oscillator and a 1-Hz signal use to trigger the radiofrequency system and instrumentation acquisition. The synchronization scheme and performance are detailed. Long-term temporal and intensity drifts are identified and actively suppressed to within 1 ps and 1.5%, respectively. Measurement and optimization of the laser's temporal profile are accomplished using frequency-resolved optical gating.

  3. Synchronization and Characterization of an Ultra-Short Laser for Photoemission and Electron-Beam Diagnostics Studies at a Radio Frequency Photoinjector

    CERN Document Server

    Maxwell, Timothy; Piot, Philippe; Lumpkin, Alex

    2012-01-01

    A commercially-available titanium-sapphire laser system has recently been installed at the Fermilab A0 photoinjector laboratory in support of photoemission and electron beam diagnostics studies. The laser system is synchronized to both the 1.3-GHz master oscillator and a 1-Hz signal use to trigger the radiofrequency system and instrumentation acquisition. The synchronization scheme and performance are detailed. Long-term temporal and intensity drifts are identified and actively suppressed to within 1 ps and 1.5%, respectively. Measurement and optimization of the laser's temporal profile are accomplished using frequency-resolved optical gating.

  4. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  5. High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Deng, B. H., E-mail: bdeng@trialphaenergy.com; Beall, M.; Schroeder, J.; Settles, G.; Feng, P.; Kinley, J. S.; Gota, H.; Thompson, M. C. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 × 10{sup 16} m{sup −2} at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations. The polarimetry achieved 0.04° instrument resolution and 0.1° actual resolution in the challenging high density gradient environment with >0.5 MHz bandwidth, making it suitable for weak internal magnetic field measurements in the C-2U plasmas, where the maximum Faraday rotation angle is less than 1°. The polarimetry resolution data is analyzed, and high resolution Faraday rotation data in C-2U is presented together with direct evidences of field reversal in FRC magnetic structure obtained for the first time by a non-perturbative method.

  6. High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas

    Science.gov (United States)

    Deng, B. H.; Beall, M.; Schroeder, J.; Settles, G.; Feng, P.; Kinley, J. S.; Gota, H.; Thompson, M. C.

    2016-11-01

    A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 × 1016 m-2 at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations. The polarimetry achieved 0.04° instrument resolution and 0.1° actual resolution in the challenging high density gradient environment with >0.5 MHz bandwidth, making it suitable for weak internal magnetic field measurements in the C-2U plasmas, where the maximum Faraday rotation angle is less than 1°. The polarimetry resolution data is analyzed, and high resolution Faraday rotation data in C-2U is presented together with direct evidences of field reversal in FRC magnetic structure obtained for the first time by a non-perturbative method.

  7. Multi-pulse operation of a dissipative soliton fibre laser based on nonlinear polarisation rotation

    Energy Technology Data Exchange (ETDEWEB)

    Yu, H L; Wang, X L; Zhou, P; Chen, J B [College of Optoelectronics Science and Engineering, National University of Defense Technology, Changsha, Hunan, 410073 (China)

    2016-03-31

    We report an experimental observation of multiple dissipative soliton (DS) operation states in an all-normal-dispersion passively mode-locked Yb-doped fibre laser, including DS bound and oscillating states. In the bound state, multiple DSs up to 11 can coexist in the cavity. In the oscillating state, the DSs' movements are not purely random and three typical states are generalised and illustrated. A single-pulse mode-locked state is established at a high pump power by carefully adjusting the polarisation controllers. The broad spectrum indicates that it may be noise-like pulses, which can serve as a pump to generate a supercontinuum. (control of laser radiation parameters)

  8. Nonlinear optics

    CERN Document Server

    Boyd, Robert W

    2013-01-01

    Nonlinear Optics is an advanced textbook for courses dealing with nonlinear optics, quantum electronics, laser physics, contemporary and quantum optics, and electrooptics. Its pedagogical emphasis is on fundamentals rather than particular, transitory applications. As a result, this textbook will have lasting appeal to a wide audience of electrical engineering, physics, and optics students, as well as those in related fields such as materials science and chemistry.Key Features* The origin of optical nonlinearities, including dependence on the polarization of light* A detailed treatment of the q

  9. Nonlinear Dynamics of Self-Pulsing All-Solid-State Lasers

    Science.gov (United States)

    2015-07-06

    NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Centro de Investigaciones en Laseres,y Aplicaciones (CEILAP), , , 8...NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 1. Centro de Investigaciones en Láseres y Aplicaciones...de Investigaciones en Láseres y Aplicaciones (CEILAP), CITEDEF-CONICET, J.B. de La Salle 4397, (1603) Villa Martelli, Argentina. Nahuel M. Granese

  10. Optical nonlinearities in GaSe and InSe crystals upon laser excitation

    Science.gov (United States)

    Kyazym-zade, A. G.; Salmanov, V. M.; Guseinov, A. G.; Gasanova, L. G.; Mamedov, R. M.

    2014-04-01

    The nonlinear absorption of light and its temporal evolution in the vicinity of exciton resonance in layered GaSe and InSe crystals under high optical excitation have been experimentally investigated. The decisive factor for the observed temporal dependence of the absorption coefficient and its dependence on the excitation intensity is screening excitons by nonequilibrium-carrier plasma. It is shown that the increase in the transmittance in the absorption-band edge in GaSe with a simultaneous blue shift of the band edge is caused by filling the energy bands under high optical excitation.

  11. Laser Spectrometric Measurement System for Local Express Diagnostics of Flame at Combustion of Liquid Hydrocarbon Fuels

    Science.gov (United States)

    Kobtsev, V. D.; Kozlov, D. N.; Kostritsa, S. A.; Smirnov, V. V.; Stel'makh, O. M.; Tumanov, A. A.

    2016-03-01

    A laboratory laser spectrometric measurement system for investigation of spatial distributions of local temperatures in a flame at combustion of vapors of various liquid hydrocarbon fuels in oxygen or air at atmospheric pressure is presented. The system incorporates a coherent anti-Stokes Raman spectrometer with high spatial resolution for local thermometry of nitrogen-containing gas mixtures in a single laser shot and a continuous operation burner with a laminar diffusion flame. The system test results are presented for measurements of spatial distributions of local temperatures in various flame zones at combustion of vapor—gas n-decane/nitrogen mixtures in air. Its applicability for accomplishing practical tasks in comparative laboratory investigation of characteristics of various fuels and for research on combustion in turbulent flames is discussed.

  12. Development of a trans-rotational temperature diagnostic for vibrationally-excited carbon monoxide using single- photon laser-induced fluorescence

    Science.gov (United States)

    Leiweke, Robert John

    2004-09-01

    A new trans-rotational temperature diagnostic with ±50K accuracy has been developed for use in nonequilibrium, low temperature, monatomic gases seeded with carbon monoxide (CO). The scheme utilizes single- photon laser induced fluorescence (LIF) of CO under vibrationally-excited conditions in which single-photon transitions from the CO X1Σ + ground electronic state to upper electronic A1Π or D'1Σ+ states become accessible to a tunable, narrowband ArF excimer laser at 193 nm. Two vibrationally excited environments in which the chemistry is well understood were used as a testbed; an optically-pumped 3% CO/Ar plasma at 100 torr and a 4% CO/He d.c. glow discharge at 8 torr. The LIF saturation limit was experimentally investigated and diagnostic advantages of either regime discussed. For the optically-pumped CO/Ar plasma, a spatially-averaged LIF temperature of 536 ± 103 K (2σ) was obtained from rotationally resolved X 1Σ+ (v' = 20) → D '1Σ+ (v' = 2) LIF excitation spectra. Temperature measurements pumping the X 1Σ+ (v' = 7) → A 1Π (v' = 1) 4th Positive (528 ± 51 K) were also found to compare well with line-of-sight Fourier Transform-InfraRed (FT-IR) emission measurements (536 ± 10 K). Spatially averaged FT- IR spectroscopy of the CO 1st overtone was used to verify that an adequate vibrational population (˜0.1%) existed within the positive column of the CO/He d.c. glow discharge. The A-X (7,1) transition was pumped and subsequent (8,1) emission at 200.8 nm collected. The resulting rotational spectral peaks were assigned and a subset used to determine a spatially averaged rotational temperature of 432 ± 44 K on the discharge centerline. This was found to be in good agreement with FT-IR spectroscopy measurements (395 ± 10 K). As a prelude to Planar-LIF (PLIF) temperature measurements, vibrationally-resolved emission from laser excitation of various rotational lines within the A-X and D'-X bands were used to investigate spectral interferences. This

  13. Laser-induced breakdown spectroscopy of dental lesions: diagnostic and therapeutic monitoring tool

    Science.gov (United States)

    Borisova, Ekaterina; Uzunov, Tzonko; Penev, Dimitar; Genova, Tsanislava; Avramov, Latchezar

    2016-01-01

    The carious decay develops a tiny area of demineralization on the enamel, which could be detected by element analytic techniques such as laser-induced breakdown spectroscopy (LIBS). That demineralization can quickly turn into a large lesion inside the tooth, it is often discovered too late to prevent the kind of decay that leads to cavities. The same optical LIBS detection approach could be used for monitoring of the caries removal using laser ablation or drilling techniques. For LIBS measurements we applied LIBS 2500Plus (Ocean Optics Inc., Dunedin, USA) system, which consists of seven spectrometric channels, covering spectral region from 200 to 980 nm, which optical resolution 0,05 nm, the spectrometers are connected with sample fiber bundle for 7-channels spectral system to the chamber for solid and liquid samples, Q-switched Nd:YAG laser, at 1 064 nm, with energy per pulse - 40 mJ, which is applied to induce plasma in the samples. LIBS spectra were obtained after single shot of the laser in the region of pathology. Samples investigated by LIBS are extracted teeth from patients, with periodontal problems on different stage of carious lesions, and their LIBS spectra are compared with the LIBS signals obtained from normal enamel and dentine tissues to receive complete picture of the carious lesion development. The major line of our investigations is related to the development of a methodology for real-time optical feedback control during selective ablation of tooth tissues using LIBS. Tooth structures, with and without pathological changes, are compared and their LIBS element analysis is used to differentiate major changes, which occur during tooth carious process and growth.

  14. Laser flash photolysis studies of atmospheric free radical chemistry using optical diagnostic techniques

    Science.gov (United States)

    Wine, Paul H.; Nicovich, J. M.; Hynes, Anthony J.; Stickel, Robert E.; Thorn, R. P.; Chin, Mian; Cronkhite, Jeffrey A.; Shackelford, Christie J.; Zhao, Zhizhong; Daykin, Edward P.

    1993-01-01

    Some recent studies carried out in our laboratory are described where laser flash photolytic production of reactant free radicals has been combined with reactant and/or product detection using time-resolved optical techniques to investigate the kinetics and mechanisms of important atmospheric chemical reactions. Discussed are (1) a study of the radical-radical reaction O + BrO yields Br + O2 where two photolysis lasers are employed to prepare the reaction mixture and where the reactants O and BrO are monitored simultaneously using atomic resonance fluorescence to detect O and multipass UV absorption to detect BrO; (2) a study of the reaction of atomic chlorine with dimethylsulfide (CH3SCH3) where atomic resonance fluorescence detection of Cl is employed to elucidate the kinetics and tunable diode laser absorption spectroscopy is employed to investigate the HCl product yield; and (3) a study of the aqueous phase chemistry of Cl2(-) radicals where longpath UV absorption spectroscopy is employed to investigate the kinetics of the Cl2(-) + H2O reaction.

  15. The use of ultraviolet Thomson scattering as a versatile diagnostic for detailed measurements of a collisional laser produced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Tracy, M.D.

    1993-01-08

    Collective Thomson scattering from ion-acoustic waves at 266nm is used to obtain spatially resolved, two-dimensional electron density, sound speed, and radial drift profiles of a collisional laser plasma. An ultraviolet diagnostic wavelength minimizes the complicating effects of inverse bremsstrahlung and refractive turning in the coronal region of interest, where the electron densities approach n{sub c}/10. Laser plasmas of this type are important because they model some of the aspects of the plasmas found in high-gain laser-fusion pellets irradiated by long pulse widths where the laser light is absorbed mostly in the corona. The experimental results and LASNEX simulations agree within a percent standard deviation of 40% for the electron density and 50% for the sound speed and radial drift velocity. Thus it is shown that the hydrodynamics equations with classical coefficients and the numerical approximations in LASNEX are valid models of laser-heated, highly collisional plasmas. The versatility of Thomson scattering is expanded upon by extending existing theory with a Fokker-Planck based model to include plasmas that are characterized by (0 {le} k{sub ia}{lambda}{sub ii} {le} {infinity}) and ZT{sub e}/T{sub i}, where k{sub ia} is the ion- acoustic wave number, {lambda}{sub ii} is the ion-ion mean free path, Z is the ionization state of the plasma, and T{sub e}, T{sub i} are the electron and ion temperatures in electron volts respectively. The model is valid for plasmas in which the electrons are approximately collisionless, (k{sub ia}{lambda}{sub ei}, k{sub ia}{lambda}{sub ee} {ge} 1), and quasineutrality holds, ({alpha} {much_gt}1), where {alpha} = 1/k{lambda}{sub DE} and {lambda}{sub DE} is the electron Debye length. This newly developed model predicts the lineshape of the ion-acoustic Thomson spectra and when fit to experimental data provides a direct measurement of the relative thermal flow velocity between the electrons and ions.

  16. Lab-on-DVD: standard DVD drives as a novel laser scanning microscope for image based point of care diagnostics.

    Science.gov (United States)

    Ramachandraiah, Harisha; Amasia, Mary; Cole, Jackie; Sheard, Paul; Pickhaver, Simon; Walker, Chris; Wirta, Valtteri; Lexow, Preben; Lione, Richard; Russom, Aman

    2013-04-21

    We present a novel "Lab-on-DVD" system and demonstrate its capability for rapid and low-cost HIV diagnostics by counting CD4+ cells isolated from whole blood. We show that a commercial DVD drive can, with certain modifications, be turned into an improved DVD-based laser scanning microscope (DVD-LSM). The system consists of a multi-layered disposable polymer disc and a modified commercial DVD reader with rotational control for sample handling, temperature control for optimized bioassay, a photodiode array for detection, and software for signal processing and user interface - all the necessary components required for a truly integrated lab-on-a-chip system, with the capability to deliver high-resolution images down to 1 μm in size. Using discs modified with antibodies, we specifically captured CD4+ cells from whole blood, demonstrating single cell resolution imaging. The novel integrated DVD platform with sub-micron image resolution brings, for the first time, affordable cellular diagnostic testing to the point-of-care and should be readily applicable at resource-limited settings.

  17. Angle-Resolved Scatter Measurements of Laser Damaged DKDP Crystals Using a Bi-Directional Scatter Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fluck, R; Wegner, P; Sheehan, L; Hackel, L A

    2000-12-22

    We built a bi-directional scatter diagnostics to measure and quantify losses due to scattering and absorption of harmonic conversion crystals (DKDP) for the National Ignition Facility (NIF). The main issues to be addressed are (1) amount of total energy reaching the target if the target hole was {+-}200 {micro}rad in size, (2) distribution of energy inside the target hole, (3) collateral damage of other optics by scattered light. The scatter diagnostics enables angle-resolved measurements at 351 nm, and is capable of both near specular transmission and large angle scatter measurements. In the near specular setup, the transmission can be measured within {+-}65 {micro}rad up to {+-}60 mrad acceptance angle. A silicon photo detector and a scientific-grade CCD camera provide total energy and energy distribution. A linear swing arm detection system enables large angle scatter measurements of 360{sup o}, in principal, with step sizes as small as 0.01{sup o} and different collection angle ranging between 1 and 20 mad. In this paper, scatter effects from laser damage and final finishing process of DKDP are discussed.

  18. Efficiency of non-linear frequency conversion of double-scale pico-femtosecond pulses of passively mode-locked fiber laser.

    Science.gov (United States)

    Smirnov, Sergey V; Kobtsev, Sergey M; Kukarin, Sergey V

    2014-01-13

    For the first time we report the results of both numerical simulation and experimental observation of second-harmonic generation as an example of non-linear frequency conversion of pulses generated by passively mode-locked fiber master oscillator in different regimes including conventional (stable) and double-scale (partially coherent and noise-like) ones. We show that non-linear frequency conversion efficiency of double-scale pulses is slightly higher than that of conventional picosecond laser pulses with the same energy and duration despite strong phase fluctuations of double-scale pulses.

  19. Generation of microwave radiation by nonlinear interaction of a high-power, high-repetition rate, 1064-nm laser in KTP crystals

    CERN Document Server

    Borghesani, A F; Carugno, G

    2013-01-01

    We report measurements of microwave (RF) generation in the centimeter band accomplished by irradiating a nonlinear KTiOPO$_4$ (KTP) crystal with a home-made, infrared laser at $1064\\,$nm as a result of optical rectification (OR). The laser delivers pulse trains of duration up to $1\\,\\mu$s. Each train consists of several high-intensity pulses at an adjustable repetition rate of approximately $ 4.6\\,$GHz. The duration of the generated RF pulses is determined by that of the pulse trains. We have investigated both microwave- and second harmonic (SHG) generation as a function of the laser intensity and of the orientation of the laser polarization with respect to the crystallographic axes of KTP.

  20. Generation of 3.5 W of diffraction-limited green light from SHG of a single tapered diode laser in a cascade of nonlinear crystals

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh; Jensen, Ole Bjarlin; Sumpf, Bernd

    2014-01-01

    -focusing and dispersion compensating optics between the two nonlinear crystals. In the low-power limit, such a cascade of two crystals has the theoretical potential for generation of four times as much power as a single crystal without adding significantly to the complexity of the system. The experimentally achieved...... frequency conversion of infrared tapered diode lasers. Here, we describe the generation of 3.5 W of diffraction-limited green light from SHG of a single tapered diode laser, itself yielding 10 W at 1063 nm. This SHG is performed in single pass through a cascade of two PPMgO:LN crystals with re...... power of 3.5 W corresponds to a power enhancement greater than 2 compared to SHG in each of the crystals individually and is the highest visible output power generated by frequency conversion of a single diode laser. Such laser sources provide the necessary pump power for biophotonics applications...