WorldWideScience

Sample records for noninvasive blood pressure

  1. The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    Science.gov (United States)

    Shangguan, Qing; Wu, Yanqing; Xu, Jinsong; Su, Hai; Li, Juxiang; Hong, Kui; Cheng, Xiaoshu

    2015-12-01

    To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP) were measured simultaneously before coronary angiography. The noninvasive BP was measured using an electronic oscillometric device with an adult cuff (12×22 cm). The mid-ACs were measured. Thus, proper cuff-arm (≤26 cm) and small cuff (>26 cm) groups were created. The difference in intra-aortic and noninvasive BP was calculated as BPi-n. The correlation coefficients (r) between noninvasive and invasive systolic blood pressure (SBP), mean artery pressure, and diastolic blood pressure (DBP) were 0.88, 0.76, and 0.58, respectively. The SBPi-n was higher (7.9±1.6 vs. 5.2±1.1 mmHg), but the DBPi-n (3.9±1.4 vs. 6.1±1.0 mmHg, P26 cm. Among the four subgroups divided by 20-23, 24-26, 27-30, and 31-37 cm of AC, as the AC increased, the SBPi-n increased, but DBP decreased, resulting in noninvasive SBP 4.6 mmHg higher and noninvasive DBP 4.6 mmHg lower in the 31-37 cm group in comparison with the 20-23 cm group. When an adult cuff was used, the noninvasive oscillometric SBP was overestimated, but DBP was underestimated in the individuals with large arms against the intra-aortic BP.

  2. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure

    NARCIS (Netherlands)

    Imholz, B. P.; Settels, J. J.; van der Meiracker, A. H.; Wesseling, K. H.; Wieling, W.

    1990-01-01

    The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during

  3. Estimation of blood pressure from non-invasive data.

    Science.gov (United States)

    Shukla, Satya Narayan

    2017-07-01

    Blood pressure (BP) is one of the most important physiological parameter that can provide crucial information for health care. The widely used cuff based technology is not very convenient or comfortable as it occludes the blood flow in the arteries during the time of measurement. In past, Phonocardiogram (PCG), Electrocardiogram (ECG) and Photoplethysmogram (PPG) signals have been used to predict the BP values. In this paper, we propose to estimate the blood pressure from PPG using Multi Task Gaussian Processes (MTGPs) and compare with Artificial Neural networks (ANNs). Both MTGPs and ANNs are evaluated on the clinical data obtained from MIMIC Database. The performance of the proposed method is found to be comparable or better than the existing methods of computing BP from non-invasive data.

  4. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  5. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  6. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  7. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  8. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  9. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  10. A novel wearable device for continuous, non-invasion blood pressure measurement.

    Science.gov (United States)

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  11. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    Science.gov (United States)

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  12. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    International Nuclear Information System (INIS)

    McCarthy, B M; O'Flynn, B; Mathewson, A

    2011-01-01

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  13. Neonatal/infant validation study of the CAS model 740 noninvasive blood pressure monitor with the Orion/MaxIQ NIBP module.

    Science.gov (United States)

    Lang, Sean M; Giuliano, John S; Carroll, Christopher L; Rosenkrantz, Ted S; Eisenfeld, Leonard

    2014-06-01

    Blood pressure monitoring is an essential vital sign when caring for critically ill children. Invasive monitoring is considered the gold standard, but is not always feasible. The following study compared the CAS model 740 noninvasive blood pressure monitor with the Orion/MaxIQ NIBP module with the reference (invasive arterial measurement). We evaluated the validity of the system using the criteria provided by the Association for the Advancement of Medical Instrumentation. We performed paired measurements of 29 critically ill neonates and children. For individual paired comparisons, the mean difference in the systolic blood pressure was 2.42 mmHg (SD ± 6.3). The mean difference in the diastolic blood pressure was -1.29 mmHg (SD ± 5.45). The percentage of readings within 5, 10, and 15 mmHg for systolic blood pressure was 65.6, 86.0, and 96.8%, respectively. The percentage of readings within 5, 10, and 15 mmHg for diastolic blood pressure was 77.7, 93, and 95.5%, respectively. The CAS model 740 noninvasive blood pressure monitor with the Orion/MaxIQ NIBP module fulfills the accuracy performance criteria of the Association for the Advancement of Medical Instrumentation. This model may allow for rapid and accurate noninvasive blood pressure monitoring in neonates and children.

  14. Noninvasive estimation of pulmonary arterial pressure by analysis of pulmonary blood-flow distribution

    International Nuclear Information System (INIS)

    Konstam, M.A.; Strauss, H.W.; Alpert, N.M.; Miller, S.W.; Murphy, R.X.; Greene, R.E.; McKusick, K.A.

    1979-01-01

    To determine whether a correlation exists between pulmonary arterial (PA) pressure (P/sub a/) and the distribution of pulmonary blood flow, this distribution was measured in four upright dogs in the control state and during intravenous infusions of epinephrine or prostaglandin F/sub 2α/. During suspension of respiration, 15 mCi of Xe-133 were injected intravenously, and perfusion and equilibration lung images were recorded with a scintillation camera. The procedure was performed several times on each dog, with and without pharmacological elevation of PA pressure by 5 to 50 cm H 2 O. For each scintigram, the relative blood flow per unit ventilated lung volume (F) was plotted against centimeters above the hilum (h). Pulmonary arterial pressure was derived from each curve, assuming the relation F = B(P/sub a/ - hD) 2 , where B = constant and D = specific gravity of blood. Calculated PA pressure correlated strongly (r = 0.83) with measured PA pressure, suggesting a possible means of noninvasive estimation of PA pressure

  15. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  16. Observational study comparing non-invasive blood pressure measurement at the arm and ankle during caesarean section.

    Science.gov (United States)

    Drake, M J P; Hill, J S

    2013-05-01

    Upper-arm non-invasive blood pressure measurement during caesarean section can be uncomfortable and unreliable because of movement artefact in the conscious parturient. We aimed to determine whether ankle blood pressure measurement could be used instead in this patient group by comparing concurrent arm and ankle blood pressure measured throughout elective caesarean section under regional anaesthesia in 64 term parturients. Bland-Altman analysis of mean difference (95% limits of agreement [range]) between the ankle and arm was 11.2 (-20.3 to +42.7 [-67 to +102]) mmHg for systolic arterial pressure, -0.5 (-21.0 to +19.9 [-44 to +91]) mmHg for mean arterial pressure and -3.8 (-25.3 to +17.8 [-41 to +94]) mmHg for diastolic arterial pressure. Although ankle blood pressure measurement is well tolerated and allows greater mobility of the arms than measurement from the arm, the degree of discrepancy between the two sites is unacceptable to allow routine use of ankle blood pressure measurement, especially for systolic arterial pressure. However, ankle blood pressure measurement may be a useful alternative in situations where arm blood pressure measurement is difficult or impossible. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  17. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  18. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  19. Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive).

    Science.gov (United States)

    Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry

    2013-11-01

    To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.

  20. Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit.

    Science.gov (United States)

    Saherwala, Ali A; Stutzman, Sonja E; Osman, Mohamed; Kalia, Junaid; Figueroa, Stephen A; Olson, DaiWai M; Aiyagari, Venkatesh

    2018-03-22

    The correlation between noninvasive (oscillometric) blood pressure (NBP) and intra-arterial blood pressure (IAP) in critically ill patients receiving vasoactive medications in a Neurocritical Care Unit has not been systematically studied. The purpose of this study is to examine the relationship between simultaneously measured NBP and IAP recordings in these patients. Prospective observational study of patients (N = 70) admitted to a neurocritical care unit receiving continuous vasopressor or antihypertensive infusions. Paired NBP/IAP observations along with covariate and demographic data were abstracted via chart audit. Analysis was performed using SAS v9.4. A total of 2177 paired NBP/IAP observations from 70 subjects (49% male, 63% white, mean age 59 years) receiving vasopressors (n = 21) or antihypertensive agents (n = 49) were collected. Paired t test analysis showed significant differences between NBP versus IAP readings: ([systolic blood pressure (SBP): mean = 136 vs. 140 mmHg; p blood pressure (DBP): mean = 70 vs. 68 mmHg, p blood pressure (MAP): mean = 86 vs. 90 mmHg, p blood pressures. Pearson correlation coefficients show strong positive correlations for paired MAP (r = 0.82), SBP (r = 0.84), and DBP (r = 0.73) recordings. An absolute NBP-IAP SBP difference of > 20 mmHg was seen in ~ 20% of observations of nicardipine, ~ 25% of observations of norepinephrine, and ~ 35% of observations of phenylephrine. For MAP, the corresponding numbers were ~ 10, 15, and 25% for nicardipine, norepinephrine, and phenylephrine, respectively. Despite overall strong positive correlations between paired NBP and IAP readings of MAP and SBP, clinically relevant differences in blood pressure are frequent. When treating with vasoactive infusions targeted to a specific BP goal, it is important to keep in mind that NBP and IAP values are not interchangeable.

  1. Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Bilo, Grzegorz; Zorzi, Cristina; Ochoa Munera, Juan E; Torlasco, Camilla; Giuli, Valentina; Parati, Gianfranco

    2015-10-01

    The present study aimed to evaluate the accuracy of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults (11 women, mean age 63.5±11.9 years) using a mercury sphygmomanometer (two observers) and the Somnotouch-NIBP device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the validation requirements were fulfilled. The Somnotouch-NIBP device fulfilled the requirements of the part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 75/99, 90/99, and 96/99, respectively, for systolic blood pressure and 90/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-seven and 31 participants had at least two of the three device-observers differences less than or equal to 5 mmHg for systolic and diastolic blood pressure, respectively. All three device-observer differences were greater than 5 mmHg in two participants for systolic and in one participant for diastolic blood pressure. The Somnotouch-NIBP noninvasive continuous blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure monitoring in adults, at least under conditions corresponding to those investigated in our study.

  2. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    Science.gov (United States)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  3. Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?

    NARCIS (Netherlands)

    Langewouters, G. J.; Settels, J. J.; Roelandt, R.; Wesseling, K. H.

    1998-01-01

    In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkoff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the

  4. Association between temporal mean arterial pressure and brachial noninvasive blood pressure during shoulder surgery in the beach chair position during general anesthesia.

    Science.gov (United States)

    Triplet, Jacob J; Lonetta, Christopher M; Everding, Nathan G; Moor, Molly A; Levy, Jonathan C

    2015-01-01

    Estimation of cerebral perfusion pressure during elective shoulder surgery in the beach chair position is regularly performed by noninvasive brachial blood pressure (NIBP) measurements. The relationship between brachial mean arterial pressure and estimated temporal mean arterial pressure (eTMAP) is not well established and may vary with patient positioning. Establishing a ratio between eTMAP and NIBP at varying positions may provide a more accurate estimation of cerebral perfusion using noninvasive measurements. This prospective study included 57 patients undergoing elective shoulder surgery in the beach chair position. All patients received an interscalene block and general anesthesia. After the induction of general anesthesia, values for eTMAP and NIBP were recorded at 0°, 30°, and 70° of incline. A statistically significant, strong, and direct correlation between NIBP and eTMAP was found at 0° (r = 0.909, P ≤ .001), 30° (r = 0.874, P Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  6. Comparison study of upper arm and forearm non-invasive blood pressures in adult Emergency Department patients.

    Science.gov (United States)

    Schimanski, Karen; Jull, Andrew; Mitchell, Nancy; McLay, Jessica

    2014-12-01

    Forearm blood pressures have been suggested as an alternative site to measure blood pressures when the upper arm is unavailable. However there is little evidence utilising clinical populations to support this substitution. To determine agreement between blood pressures measured in the left upper arm and forearm using a singular oscillometric non-invasive device in adult Emergency Department patients. The secondary objective was to explore the relationship of blood pressure differences with age, sex, ethnicity, smoking history and obesity. Single centre comparison study. Adult Emergency Department, Tertiary Trauma Centre. Forty-four participants who met inclusion/exclusion criteria selected sequentially from the Emergency Department arrival board. A random assignment of order of measurement for left upper arm and forearm blood pressures was utilised. Participants were eligible if they were aged 18 years or older, had been assigned an Australasian Triage Scale code of 2, 3, 4, or 5, were able to consent, and able to have blood pressures measured on their left arm whilst lying at a 45° angle. The Bland-Altman method of statistical analysis was used, with the level of agreement for clinical acceptability for the systolic, diastolic and mean arterial pressure defined as ±10 mmHg. The forearm measure overestimated systolic (mean difference 2.2 mmHg, 95% limits of agreement ±19 mmHg), diastolic (mean difference 3.4 mmHg, 95% limits of agreement ±14.4 mmHg), and mean arterial pressures (mean difference 4.1 mmHg, 95% limits of agreement ±13.7 mmHg). The systolic measure was not significantly different from zero. Evidence of better agreement was found with upper arm/forearm systolic measures below 140 mmHg compared to systolic measures above 140 mmHg using the Levene's test (p=0.002, F-statistic=11.09). Blood pressure disparity was not associated with participant characteristics. Forearm measures cannot routinely replace upper arm measures for blood pressure measurement

  7. Evaluation of the cerebrovascular pressure reactivity index using non-invasive finapres arterial blood pressure

    International Nuclear Information System (INIS)

    Kasprowicz, M; Kim, D J; Haubrich, C; Czosnyka, Z; Smielewski, P; Czosnyka, M; Schmidt, E

    2010-01-01

    A pressure reactivity index (PRx) can be assessed in patients with continuous monitoring of arterial blood pressure (ABP) and intracranial pressure (ICP) as a moving correlation coefficient between slow fluctuations of these two signals within a low frequency bandwidth. The study aimed to investigate whether the invasive ABP monitoring can be replaced with non-invasive measurement of ABP using a Finapres plethysmograph (fABP) to calculate the fPRx. There is a well-defined group of patients, suffering from hydrocephalus and undergoing CSF pressure monitoring, which may benefit from such a measurement. 41 simultaneous day-by-day monitoring of ICP, ABP and fABP were performed for about 30 min in 10 head injury patients. A Bland–Altman assessment for agreement was used to compare PRx and fPRx calculations. Performance metrics and the McNemary test were used to determine whether fPRx is sensitive enough to distinguish between functioning and disturbed cerebrovascular pressure reactivity. The fPRx correlated with PRx (R Spearman = 0.92, p < 0.001; bias = −0.04; lower and upper limits of agreement: −0.26 and 0.17, respectively). The fPRx distinguished between active and passive reactivity in more than 89% cases. The fPRx can be used with care for assessment of cerebrovascular reactivity in patients for whom invasive ABP measurement is not feasible. The fPRx is sensitive enough to distinguish between functional and deranged reactivity

  8. A noninvasive estimation of cerebral perfusion pressure using critical closing pressure.

    Science.gov (United States)

    Varsos, Georgios V; Kolias, Angelos G; Smielewski, Peter; Brady, Ken M; Varsos, Vassilis G; Hutchinson, Peter J; Pickard, John D; Czosnyka, Marek

    2015-09-01

    Cerebral blood flow is associated with cerebral perfusion pressure (CPP), which is clinically monitored through arterial blood pressure (ABP) and invasive measurements of intracranial pressure (ICP). Based on critical closing pressure (CrCP), the authors introduce a novel method for a noninvasive estimator of CPP (eCPP). Data from 280 head-injured patients with ABP, ICP, and transcranial Doppler ultrasonography measurements were retrospectively examined. CrCP was calculated with a noninvasive version of the cerebrovascular impedance method. The eCPP was refined with a predictive regression model of CrCP-based estimation of ICP from known ICP using data from 232 patients, and validated with data from the remaining 48 patients. Cohort analysis showed eCPP to be correlated with measured CPP (R = 0.851, p area under the curve of 0.913 (95% CI 0.883-0.944). When each recording session of a patient was assessed individually, eCPP could predict CPP with a 95% CI of the SD for estimating CPP between multiple recording sessions of 1.89-5.01 mm Hg. Overall, CrCP-based eCPP was strongly correlated with invasive CPP, with sensitivity and specificity for detection of low CPP that show promise for clinical use.

  9. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  10. Non-invasive ambient pressure estimation using non-linear ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup

    Many attempts to find a non-invasive procedure to measure the blood pressure locally in the body have been made. This dissertation focuses on the approaches which utilize highly compressible ultrasound contrast agents as ambient pressure sensors. The literature within the topic has been reviewed...

  11. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    Science.gov (United States)

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  12. A Pilot Study: Comparison of Arm Versus Ankle Noninvasive Blood Pressure Measurement at 2 Different Levels of Backrest Elevation.

    Science.gov (United States)

    Henley, Nicole; Quatrara, Beth D; Conaway, Mark

    2015-01-01

    Standard practice for obtaining noninvasive blood pressure includes arm blood pressure (BP) cuff placement at the level of the heart; however, some critical care patients cannot have BPs taken in their arm because of various conditions, and ankle BPs are frequently used as substitutes. The aim of this study was to determine if there was a significant variation between upper arm and ankle BP measurements at different backrest elevations with consideration of peripheral edema factors. After institutional review board approval was obtained, a pilot study was implemented to evaluate noninvasive BP measurements of the arm and ankle with backrest elevation at 0° and 30° in a population of medical intensive care unit patients. Participants served as their own controls and were randomly assigned to left- versus right-side BP readings. Data were also collected on presence of arm versus ankle edema. A total of 30 participants enrolled in the study and provided 120 BP measurements. Blood pressure readings were analyzed in terms of diastolic and systolic findings as well as backrest elevations and edema presence. Thirteen participants presented with either arm or ankle edema. There was a statistical difference between the systolic arm and ankle BP measurements in the 0° (P = .008) and 30° (P arm and ankle diastolic BP is greater for participants without ankle edema (P = .038, r = 0.54) than for participants with ankle edema (P = .650, r = 0.14), but it is not statistically significant (P = .47). Even though ankle BPs are often substituted for arm BPs when the arm is unable to be used, ankle BPs and arm BPs are not interchangeable. Adjustments in backrest elevation and considerations of edema do not normalize the differences. Blood pressures obtained from the ankle are significantly greater than those obtained from the arm. This information needs to be considered when arms are not available and legs are used as surrogates for the upper arm.

  13. Central blood pressure and chronic kidney disease

    Science.gov (United States)

    Ohno, Yoichi; Kanno, Yoshihiko; Takenaka, Tsuneo

    2016-01-01

    In this review, we focused on the relationship between central blood pressure and chronic kidney diseases (CKD). Wave reflection is a major mechanism that determines central blood pressure in patients with CKD. Recent medical technology advances have enabled non-invasive central blood pressure measurements. Clinical trials have demonstrated that compared with brachial blood pressure, central blood pressure is a stronger risk factor for cardiovascular (CV) and renal diseases. CKD is characterized by a diminished renal autoregulatory ability, an augmented direct transmission of systemic blood pressure to glomeruli, and an increase in proteinuria. Any elevation in central blood pressure accelerates CKD progression. In the kidney, interstitial inflammation induces oxidative stress to handle proteinuria. Oxidative stress facilitates atherogenesis, increases arterial stiffness and central blood pressure, and worsens the CV prognosis in patients with CKD. A vicious cycle exists between CKD and central blood pressure. To stop this cycle, vasodilator antihypertensive drugs and statins can reduce central blood pressure and oxidative stress. Even in early-stage CKD, mineral and bone disorders (MBD) may develop. MBD promotes oxidative stress, arteriosclerosis, and elevated central blood pressure in patients with CKD. Early intervention or prevention seems necessary to maintain vascular health in patients with CKD. PMID:26788468

  14. Skin necrosis in a critically ill patient due to a blood pressure cuff

    Directory of Open Access Journals (Sweden)

    Devbhandari Mohan

    2006-01-01

    Full Text Available The non-invasive method of blood pressure measurement is regarded as a safe procedure and the reports of any serious complications are rare. We report a unique case of extensive skin necrosis due to an intermittently inflating blood pressure cuff in a 65-year-old critically ill lady following a third time redo mitral valve surgery. A brief review of the literature on complications associated with noninvasive method of measurement of blood pressure is presented along with possible mechanisms of skin injury and ways to avoid it.

  15. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    Science.gov (United States)

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  16. Toe blood pressure and leg muscle oxygenation with body posture.

    Science.gov (United States)

    Rosales-Velderrain, Armando; Cardno, Michael; Mateus, Jaime; Kumar, Ravindra; Schlabs, Thomas; Hargens, Alan R

    2011-05-01

    In 1980 Katkov and Chestukhin measured blood pressures and oxygenation invasively at various body tilt angles at different locations on the body, including the foot. To our knowledge, such measurements have not been performed noninvasively. Therefore, the purpose of this study was to measure toe blood pressure (TBP) and lower limb muscle oxygenation noninvasively at various body tilt angles, and to assess the use of a Finometer for noninvasive TBP measurements. Our noninvasive results are compared with those performed by Katkov and Chestukhin. We hypothesized that: 1) the Finometer provides a noninvasive measurement of TBP at different tilt angles; and 2) muscle oxygenation is highest with 0 and -6 degrees, and decreases with increased head-up tilt (HUT). There were 10 subjects who were exposed to different body tilt angles (-6, 0, 10, 30, 70, and 90 degrees). At each angle we measured TBP noninvasively with a Finometer and muscle tissue oxygenation by near infrared spectroscopy. We found a strong correlation between TBP using the Finometer and TBP predicted by adding the hydrostatic component due to body tilt to the standard arm blood pressure measurement. At 10, 30, 70, and 90 degrees both TBP and tissue oxygenation were significantly different from the 0 degree (supine) level. Oxygenation decreased and TBP increased with higher HUT angles. No differences were observed in TBP or oxygenation between -6 and 0 degree. The Finometer accurately measures TBP noninvasively with body tilt. Also, muscle oxygenation is highest at small HUT angles and decreases with increased HUT.

  17. Assessment of blood gas parameters and the degree of inflammation in noninvasive positive pressure ventilation combined with aminophylline treatment of COPD complicated with type II respiratory failure

    Directory of Open Access Journals (Sweden)

    Jin-Ru Zhang

    2016-10-01

    Full Text Available Objective: To analyze the effect of noninvasive positive pressure ventilation combined with aminophylline therapy on blood gas parameters and the degree of inflammation in patients with COPD and type II respiratory failure. Methods: A total of 80 patients with COPD and type Ⅱ respiratory failure were randomly divided into observation group and control group (n=40, control group received symptomatic treatment + aminophylline treatment, observation group received symptomatic treatment + aminophylline + noninvasive positive pressure ventilation treatment, and then differences in blood gas parameters, pulmonary function parameters, hemorheology parameters and inflammatory factor levels were compared between two groups of patients after treatment. Results: Radial artery pH and PO2 values of observation group after treatment were higher than those of control group while PCO2, Cl- and CO2CP values were lower than those of control group; pulmonary function parameters FVC, FEV1, FEF25-75, MMF, PEF and FRC values of observation group after treatment were higher than those of control group; whole blood viscosity (150 s- and 10 s-, plasma viscosity, fibrinogen, erythrocyte aggregation index and erythrocyte rigidity index values in peripheral venous blood of observation group after treatment were lower than those of control group; serum IL-17, IL-33, TREM-1, sICAM-1 and PGE2 levels of observation group after treatment were lower than those of control group. Conclusion: Noninvasive positive pressure ventilation combined with aminophylline can optimize the respiratory function of patients with COPD and type II respiratory failure and improve blood gas parameters and the degree of inflammation.

  18. Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI

    Science.gov (United States)

    Delles, Michael; Rengier, Fabian; Azad, Yoo-Jin; Bodenstedt, Sebastian; von Tengg-Kobligk, Hendrik; Ley, Sebastian; Unterhinninghofen, Roland; Kauczor, Hans-Ulrich; Dillmann, Rüdiger

    2015-03-01

    In diagnostics and therapy control of cardiovascular diseases, detailed knowledge about the patient-specific behavior of blood flow and pressure can be essential. The only method capable of measuring complete time-resolved three-dimensional vector fields of the blood flow velocities is velocity-encoded magnetic resonance imaging (MRI), often denoted as 4D flow MRI. Furthermore, relative pressure maps can be computed from this data source, as presented by different groups in recent years. Hence, analysis of blood flow and pressure using 4D flow MRI can be a valuable technique in management of cardiovascular diseases. In order to perform these tasks, all necessary steps in the corresponding process chain can be carried out in our in-house developed software framework MEDIFRAME. In this article, we apply MEDIFRAME for a study of hemodynamics in the pulmonary arteries of five healthy volunteers. The study included measuring vector fields of blood flow velocities by phase-contrast MRI and subsequently computing relative blood pressure maps. We visualized blood flow by streamline depictions and computed characteristic values for the left and the right pulmonary artery (LPA and RPA). In all volunteers, we observed a lower amount of blood flow in the LPA compared to the RPA. Furthermore, we visualized blood pressure maps using volume rendering and generated graphs of pressure differences between the LPA, the RPA and the main pulmonary artery. In most volunteers, blood pressure was increased near to the bifurcation and in the proximal LPA, leading to higher average pressure values in the LPA compared to the RPA.

  19. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits.

    Science.gov (United States)

    Bellini, Luca; Veladiano, Irene A; Schrank, Magdalena; Candaten, Matteo; Mollo, Antonio

    2018-02-27

    Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. Although mean invasive

  20. Relation of blood pressure and organ damage: comparison between feasible, noninvasive central hemodynamic measures and conventional brachial measures.

    Science.gov (United States)

    Lindroos, Annika S; Langén, Ville L; Kantola, Ilkka; Salomaa, Veikko; Juhanoja, Eeva P; Sivén, Sam S; Jousilahti, Pekka; Jula, Antti M; Niiranen, Teemu J

    2018-06-01

    The present cross-sectional study investigated whether central SBP and pulse pressure (PP) measured noninvasively with a novel cuff-based stand-alone monitor are more strongly associated with hypertensive end-organ damage than corresponding brachial measures. We investigated the cross-sectional association of central versus brachial SBP and PP with echocardiographic left ventricular mass index (LVMI), LV hypertrophy (LVH), carotid intima-media thickness (IMT), and increased IMT (IMT ≥ 75th percentile) among 246 participants drawn from the general population (mean age 57.2 years, 55.3% women). All blood pressure (BP) measures were positively correlated with LVMI and IMT (P area under curve (AUC) for SBP: 0.74 versus 0.76, P = 0.16; AUC for PP: 0.75 versus 0.73, P = 0.35] and IMT (AUC for SBP: 0.61 versus 0.61, P = 0.67; AUC for PP: 0.63 versus 0.61, P = 0.29). Our findings suggest that central SBP and PP measured with a stand-alone noninvasive BP monitor do not improve diagnostic accuracy for end-organ damage over corresponding brachial measures.

  1. A fluid-structure interaction model of the internal carotid and ophthalmic arteries for the noninvasive intracranial pressure measurement method.

    Science.gov (United States)

    Misiulis, Edgaras; Džiugys, Algis; Navakas, Robertas; Striūgas, Nerijus

    2017-05-01

    Accurate and clinically safe measurements of intracranial pressure (ICP) are crucial for secondary brain damage prevention. There are two methods of ICP measurement: invasive and noninvasive. Invasive methods are clinically unsafe; therefore, safer noninvasive methods are being developed. One of the noninvasive ICP measurement methods implements the balance principle, which assumes that if the velocity of blood flow in both ophthalmic artery segments - the intracranial (IOA) and extracranial (EOA) - is equal, then the acting ICP on the IOA and the external pressure (Pe) on the EOA are also equal. To investigate the assumption of the balance principle, a generalized computational model incorporating a fluid-structure interaction (FSI) module was created and used to simulate noninvasive ICP measurement by accounting for the time-dependent behavior of the elastic internal carotid (ICA) and ophthalmic (OA) arteries and their interaction with pulsatile blood flow. It was found that the extra balance pressure term, which incorporates the hydrodynamic pressure drop between measurement points, must be added into the balance equation, and the corrections on a difference between the velocity of blood flow in the IOA and EOA must be made, due to a difference in the blood flow rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Accuracy and Precision of Noninvasive Blood Pressure in Normo-, Hyper-, and Hypotensive Standing and Anesthetized Adult Horses.

    Science.gov (United States)

    Heliczer, N; Lorello, O; Casoni, D; Navas de Solis, C

    2016-05-01

    Blood pressure is relevant to the diagnosis and management of many medical, cardiovascular and critical diseases. The accuracy of many commonly used noninvasive blood pressure (NIBP) monitors and the accuracy of NIBP measurements in hypo- and hypertensive standing horses has not been determined. The objective of this study was to investigate the accuracy of an oscillometric BP monitor in standing horses before and during pharmacologically induced hyper- and hypotension and to compare results in standing and anesthetized horses. Eight standing mares from a research herd (SG) and eight anesthetized horses from a hospital population (AG). Prospective experimental and observational studies. Invasive blood pressure (IBP) and NIBP, corrected to heart level, were measured simultaneously. In the SG hyper- and hypotension were induced by administration of phenylephrine (3 μg/kg/min IV for 15 minutes) and acepromazine (0.05 mg/kg IV), respectively. In the AG NIBP and IBP were recorded during regular hospital procedures. There was a significant correlation between mean NIBP and IBP in standing (R = 0.88, P horses (R = 0.81, P horses, but in the SG significant correlation between NIBP and IBP was only detected for the normotensive phase. While the evaluated oscillometric BP device allowed estimation of BP and adequately differentiated marked trends, the accuracy and precision were low in standing horses. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. Comparison of high-definition oscillometry -- a non-invasive technology for arterial blood pressure measurement -- with a direct invasive method using radio-telemetry in awake healthy cats.

    Science.gov (United States)

    Martel, Eric; Egner, Beate; Brown, Scott A; King, Jonathan N; Laveissiere, Arnaud; Champeroux, Pascal; Richard, Serge

    2013-12-01

    This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into account all pressure ranges, and with data separated in three sub-groups, low, normal and high ranges of systolic (SBP) and diastolic (DBP) blood pressure. SBP data displayed a mean correlation coefficient of 0.92 ± 0.02 that was reduced for low SBP. The agreement level evaluated from the whole data set was high and slightly reduced for low SBP values. The mean correlation coefficient of DBP was lower than for SBP (ie, 0.81 ± 0.02). The bias for DBP between the two methods was 22.3 ± 1.6 mmHg, suggesting that HDO produced lower values than telemetry. These results suggest that HDO met the validation criteria defined by the American College of Veterinary Internal Medicine consensus panel and provided a faithful measurement of SBP in conscious cats. For DBP, results suggest that HDO tended to underestimate DBP. This finding is clearly inconsistent with the good agreement reported in dogs, but is similar to outcomes achieved in marmosets and cynomolgus monkeys, suggesting that this is not related to HDO but is species related. The data support that the HDO is the first and only validated non-invasive blood pressure device and, as such, it is the only non-invasive reference technique that should be used in future validation studies.

  4. Effect of adjuvant noninvasive positive pressure ventilation on blood gas parameters, cardiac function and inflammatory state in patients with COPD and type II respiratory failure

    Directory of Open Access Journals (Sweden)

    You-Ming Zhu1

    2017-03-01

    Full Text Available Objective: T o analyze the effect of adjuvant noninvasive positive pressure ventilation on blood gas parameters, cardiac function and inflammatory state in patients with chronic obstructive pulmonary disease (COPD and type II respiratory failure. Methods: 90 patients with COPD and type II respiratory failure were randomly divided into observation group and control group (n=45. Control group received conventional therapy, observation group received conventional therapy + adjuvant noninvasive positive pressure ventilation, and differences in blood gas parameters, cardiac function, inflammatory state, etc., were compared between two groups of patients 2 weeks after treatment. Results: Arterial blood gas parameters pH and alveolar-arterial partial pressure of oxygen [P(A-aO2] levels of observation group were higher than those of control group while, potassium ion (K+, chloride ion (Cl﹣ and carbon dioxide combining power (CO2CP levels were lower than those of control group 2 weeks after treatment; echocardiography parameters Doppler-derived tricuspid lateral annular systolic velocity (DTIS and pulmonary arterial velocity (PAV levels were lower than those of control group (P<0.05 while pulmonary artery accelerating time (PAACT, left ventricular enddiastolic dimension (LVDd and right atrioventricular tricuspid annular plane systolic excursion (TAPSE levels were higher than those of control group (P<0.05; serum cardiac function indexes adiponectin (APN, Copeptin, N-terminal pro-B-type natriuretic peptide (NT-proBNP, cystatin C (CysC, growth differentiation factor-15 (GDF-15 and heart type fatty acid binding protein (H-FABP content were lower than those of control group (P<0.05; serum inflammatory factors hypersensitive C-reactive protein (hs-CRP, tumor necrosis factor-α (TNF-α, interleukin-1β (IL-1β, IL-8, IL-10, and transforming growth factor-β1 (TGF-β1 content were lower than those of control group (P<0.05. Conclusions: Adjuvant

  5. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  6. Non-invasive estimation of blood pressure using ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an experimental setup for investigating the ambient pressure sensitivity of a contrast agent using...

  7. Wearing an abdominal belt increases diastolic blood pressure.

    Science.gov (United States)

    Rafacz, W; McGill, S M

    1996-09-01

    The purpose of this study was to determine the effect of wearing an abdominal belt on blood pressure (systolic and diastolic) and heart rate during a variety of tasks. The belt was typical of the elastic type with suspenders and Velcro tabs for cinching the belt snug. The tasks performed included sitting at rest, sitting with the torso inclined forward at 45 degrees, standing with the torso inclined forward at 45 degrees (with and without holding an 11-kg weight), a trunk axial rotation task, and squat lifting. Blood pressure was monitored noninvasively with a FINAPRES blood pressure monitor. Twenty healthy men performed each task with and without the abdominal belt. Although no significant increases in mean systolic blood pressure or heart rate were found, there was a significant increase in diastolic blood pressure in all conditions. All people considering wearing an abdominal belt should also consider the risks and liability associated with the additional cardiovascular load, particularly heart attack and stroke.

  8. Central blood pressure in children and adolescents: non-invasive development and testing of novel transfer functions.

    Science.gov (United States)

    Cai, T Y; Qasem, A; Ayer, J G; Butlin, M; O'Meagher, S; Melki, C; Marks, G B; Avolio, A; Celermajer, D S; Skilton, M R

    2017-12-01

    Central blood pressure can be estimated from peripheral pulses in adults using generalised transfer functions (TF). We sought to create and test age-specific non-invasively developed TFs in children, with comparison to a pre-existing adult TF. We studied healthy children from two sites at two time points, 8 and 14 years of age, split by site into development and validation groups. Radial and carotid pressure waveforms were obtained by applanation tonometry. Central systolic pressure was derived from carotid waveforms calibrated to brachial mean and diastolic pressures. Age-specific TFs created in the development groups (n=50) were tested in the validation groups aged 8 (n=137) and 14 years (n=85). At 8 years of age, the age-specific TF estimated 82, 99 and 100% of central systolic pressure values within 5, 10 and 15 mm Hg of their measured values, respectively. This TF overestimated central systolic pressure by 2.2 (s.d. 3.7) mm Hg, compared to being underestimated by 5.6 (s.d. 3.9) mm Hg with the adult TF. At 14 years of age, the age-specific TF estimated 60, 87 and 95% of values within 5, 10 and 15 mm Hg of their measured values, respectively. This TF underestimated central systolic pressure by 0.5 (s.d. 6.7) mm Hg, while the adult TF underestimated it by 6.8 (s.d. 6.0) mm Hg. In conclusion, age-specific TFs more accurately predict central systolic pressure measured at the carotid artery in children than an existing adult TF.

  9. Cantilever arrayed blood pressure sensor for arterial applanation tonometry.

    Science.gov (United States)

    Lee, Byeungleul; Jeong, Jinwoo; Kim, Jinseok; Kim, Bonghwan; Chun, Kukjin

    2014-03-01

    The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.

  10. Noninvasive Ambient Pressure Estimation using Ultrasound Contrast Agents -- Invoking Subharmonics for Cardiac and Hepatic Applications

    Science.gov (United States)

    Dave, Jaydev K.

    Ultrasound contrast agents (UCAs) are encapsulated microbubbles that provide a source for acoustic impedance mismatch with the blood, due to difference in compressibility between the gas contained within these microbubbles and the blood. When insonified by an ultrasound beam, these UCAs act as nonlinear scatterers and enhance the echoes of the incident pulse, resulting in scattering of the incident ultrasound beam and emission of fundamental (f0), subharmonic (f0/2), harmonic (n*f0; n ∈ N) and ultraharmonic (((2n-1)/2)*f0; n ∈ N & n > 1) components in the echo response. A promising approach to monitor in vivo pressures revolves around the fact that the ultrasound transmit and receive parameters can be selected to induce an ambient pressure amplitude dependent subharmonic signal. This subharmonic signal may be used to estimate ambient pressure amplitude; such technique of estimating ambient pressure amplitude is referred to as subharmonic aided pressure estimation or SHAPE. This project develops and evaluates the feasibility of SHAPE to noninvasively monitor cardiac and hepatic pressures (using commercially available ultrasound scanners and UCAs) because invasive catheter based pressure measurements are used currently for these applications. Invasive catheter based pressure measurements pose risk of introducing infection while the catheter is guided towards the region of interest in the body through a percutaneous incision, pose risk of death due to structural or mechanical failure of the catheter (which has also triggered product recalls by the USA Food and Drug Administration) and may potentially modulate the pressures that are being measured. Also, catheterization procedures require fluoroscopic guidance to advance the catheter to the site of pressure measurements and such catheterization procedures are not performed in all clinical centers. Thus, a noninvasive technique to obtain ambient pressure values without the catheterization process is clinically

  11. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  12. Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.

    Science.gov (United States)

    Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther

    2017-07-01

    Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.

  13. Brachial versus central blood pressure and vascular stiffness

    DEFF Research Database (Denmark)

    Rasmussen, Susanne; Hansen, Tine; Frimodt-Møller, Marie

    2010-01-01

    Central blood pressure (BP) estimates the true load imposed on the left ventricle to a higher degree than does brachial BP. Increased aortic pulse wave velocity (aPWV) and central BP are risk markers for cardiovascular disease. Both can be measured by simple and noninvasive methods. Guidelines...

  14. Brachial versus central blood pressure and vascular stiffness

    DEFF Research Database (Denmark)

    Rasmussen, Susanne; Hansen, Tine; Frimodt-Møller, Marie

    2009-01-01

    Central blood pressure (BP) estimates the true load imposed on the left ventricle to a higher degree than does brachial BP. Increased aortic pulse wave velocity (aPWV) and central BP are risk markers for cardiovascular disease. Both can be measured by simple and noninvasive methods. Guidelines...

  15. Noninvasive Positive Pressure Ventilatory Support Begins During Sleep.

    Science.gov (United States)

    Bach, John R

    2017-12-01

    The goal of sleep doctors has been to titrate away apneas and hypopneas using noninvasive ventilation, a term that has become synonymous with continuous positive airway pressure and bilevel positive airway pressure at the lowest effective bilevel settings. It is now time to appreciate noninvasive ventilatory support as an alternative to invasive mechanical ventilation. This article discusses mechanisms of action, two paradigms, and ancillary techniques for noninvasive ventilatory support. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Noninvasive measurement of postocclusive parameters in human forearm blood by near infrared spectroscopy

    Science.gov (United States)

    Rao, K. Prahlad; Radhakrishnan, S.; Reddy, M. Ramasubba

    2005-04-01

    Near infrared (NIR) light in the wavelength range from 700 to 900 nm can pass through skin, bone and other tissues relatively easily. As a result, NIR techniques allow a noninvasive assessment of hemoglobin saturation for a wide range of applications, such as in the study of muscle metabolism, the diagnosis of vascular disorders, brain imaging, and breast cancer detection. Near infrared Spectroscopy (NIRS) is an effective tool to measure the hemoglobin concentration in the tissues, which can discriminate optically the oxy- and deoxy- hemoglobin species because of their different near-infrared absorption spectra. We have developed an NIRS probe consisting of a laser diode of 830 nm wavelength and a PIN photodiode in reflectance mode. We have selected a set of healthy volunteers (mean age 30, range 26-40 years) for the study. The probe is placed on forearm of each subject and the backscattered light intensity is measured by occluding the blood flow at 210, 110 and 85 mmHg pressures. Recovery time, peak time and time after 50% release of the cuff pressure are determined from the optical densities during the post occlusive state of forearm. These parameters are useful for determining the transient increase in blood flow after the release of blood occlusion. Clinically, the functional aspects of blood flow in the limbs could be evaluated noninvasively by NIRS.

  17. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  18. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  19. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  20. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  1. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  2. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  3. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  4. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  5. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

    Science.gov (United States)

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-12-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery-powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring.

  6. Circadian pattern of blood pressure in normal pregnancy and preeclampsia.

    Science.gov (United States)

    Gupta, Hem Prabha; Singh, R K; Singh, Urmila; Mehrotra, Seema; Verma, N S; Baranwal, Neelam

    2011-08-01

    AIMS #ENTITYSTARTX00026; To find out the circadian pattern of blood pressure in normotensive pregnant women and in women with preeclampsia. A cross-sectional prospective observational case control study. Blood pressure was sampled in thirty-five normotensive pregnant women (control) and thirty five preeclamptic women (study group) by using non-invasive automatic ambulatory blood pressure monitoring machine for 72 h. Blood pressure (BP) was not constant over 24 h period and it oscillated from time to time in control group. BP was maximum during early part of afternoon. However, in preeclampsia besides quantitative increase in BP, circadian BP oscillations were less pronounced and in around 50% subjects BP was maximum during evening and night hours. Both systolic and diastolic BP showed definite reproducible circadian pattern in both preeclamptic and normotensive pregnant women. This pattern both quantitatively and qualitatively was different in preeclamptic women. Standardized 24 h BP monitoring allows quantitative and qualitative evaluation of hypertensive status and is important for timing and dosing of antihypertensive medications.

  7. Blood Pressure Out of the Office: Its Time Has Finally Come.

    Science.gov (United States)

    Krakoff, Lawrence R

    2016-03-01

    The diagnosis of hypertension includes measurement of blood pressure out of the office by either 24-hour ambulatory monitoring or home blood pressure monitoring. These methods have led to recognition of "white coat hypertension" (WCH) and "masked hypertension" (MH). Research in the 1930s first demonstrated that blood pressures in the office were often far different from those out of the office, at a time when there was no effective treatment. International attention was focused on another imminent world war and a highly controversial election in the United States. Hypertension was not a priority for concern. From the 1950s onward: (i) epidemiology linked hypertension to risk of cardiovascular disease, (ii) effective and safe drugs for treatment of hypertension appeared, (iii) randomized clinical trials demonstrated that drug treatment of hypertension is highly effective for prevention of cardiovascular disease, and (iv) advances in technology led to development of small, portable devices for recording blood pressure noninvasively at home or during usual activities. Accurate measurement of blood pressure in "real life" is now necessary and feasible for appropriate diagnosis and assessment of treatment. Out-of-office blood pressure measurement is emerging as the standard of care for hypertension. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Intima-media thickness evaluation by B-mode ultrasound: Correlation with blood pressure levels and cardiac structures

    Directory of Open Access Journals (Sweden)

    F.L. Plavnik

    2000-01-01

    Full Text Available The aim of this study was to analyze the thickness of the intima-media complex (IMC using a noninvasive method. The carotid and femoral common arteries were evaluated by noninvasive B-mode ultrasound in 63 normotensive and in 52 hypertensive subjects and the thickness of the IMC was tested for correlation with blood pressure, cardiac structures and several clinical and biological parameters. The IMC was thicker in hypertensive than in normotensive subjects (0.67 ± 0.13 and 0.62 ± 0.16 vs 0.54 ± 0.09 and 0.52 ± 0.11 mm, respectively, P<0.0001. In normotensive patients, the simple linear regression showed significant correlations between IMC and age, body mass index and 24-h systolic blood pressure for both the carotid and femoral arteries. In hypertensives the carotid IMC was correlated with age and 24-h systolic blood pressure while femoral IMC was correlated only with 24-h diastolic blood pressure. Forward stepwise regression showed that age, body mass index and 24-h systolic blood pressure influenced the carotid IMC relationship (r2 = 0.39 in normotensives. On the other hand, the femoral IMC relationship was influenced by 24-h systolic blood pressure and age (r2 = 0.40. In hypertensives, age and 24-h systolic blood pressure were the most important determinants of carotid IMC (r2 = 0.37, while femoral IMC was influenced only by 24-h diastolic blood pressure (r2 = 0.10. There was an association between carotid IMC and echocardiographic findings in normotensives, while in hypertensives only the left posterior wall and interventricular septum were associated with femoral IMC. We conclude that age and blood pressure influence the intima-media thickness, while echocardiographic changes are associated with the IMC.

  9. Blood Pressure Test

    Science.gov (United States)

    ... pressure monitors may have some limitations. Tracking your blood pressure readings It can be helpful in diagnosing or ... more Stage 2 high blood pressure (hypertension) Elevated blood pressure and stages 1 and 2 high blood pressure ( ...

  10. Relationship between systemic hemodynamics and ambulatory blood pressure level are sex dependent.

    Science.gov (United States)

    Alfie, J; Waisman, G D; Galarza, C R; Magi, M I; Vasvari, F; Mayorga, L M; Cámera, M I

    1995-12-01

    Sex-related differences in systemic hemodynamics were analyzed by means of cardiac index and systemic vascular resistance according to the level of daytime ambulatory blood pressure. In addition, we assessed the relations between ambulatory blood pressure measurements and systemic hemodynamics in male and female patients. We prospectively included 52 women and 53 men referred to our unit for evaluation of arterial hypertension. Women and men were grouped according to the level of daytime mean arterial pressure: or = 110 mm Hg. Patients underwent noninvasive evaluation of resting hemodynamics (impedance cardiography) and 24-hour ambulatory blood pressure monitoring. Compared with women men with lower daytime blood pressure had a 12% higher systemic vascular resistance index (P = NS) and a 14% lower cardiac index (P < .02), whereas men with higher daytime blood pressure had a 25% higher vascular resistance (P < .003) and a 21% lower cardiac index (P < .0004). Furthermore, in men systemic vascular resistance correlated positively with both daytime and nighttime systolic and diastolic blood pressures, whereas cardiac index correlated negatively only with daytime diastolic blood pressure. In contrast, women did not exhibit any significant correlation between hemodynamic parameters and ambulatory blood pressure measurements. In conclusion, sex-related differences in systemic hemodynamics were more pronounced in the group with higher daytime hypertension. The relations between systemic hemodynamics and ambulatory blood pressure level depended on the sex of the patient. In men a progressive circulatory impairment underlies the increasing level of ambulatory blood pressure, but this was not observed in women.

  11. Low Blood Pressure

    Science.gov (United States)

    ... a problem. Sometimes blood pressure that is too low can also cause problems. Blood pressure is the ... reading is 90/60 or lower, you have low blood pressure. Some people have low blood pressure ...

  12. Nocturnal Blood Pressure Variability in Patients with Obstructive Sleep Apnea Syndrome.

    Science.gov (United States)

    Martynowicz, H; Porębska, I; Poręba, R; Mazur, G; Brzecka, A

    2016-01-01

    Obstructive sleep apnea (OSA) is a common respiratory disorder associated with hypertension and cardiovascular complications. Blood pressure variability may be a sign of risk of cardiovascular events. The aim of this study was to investigate the hypothesis that severe OSA syndrome is associated with increased blood pressure variability. Based on respiratory polygraphy, 58 patients were categorized into two groups: severe OSA with apnea/hypopnea index (AHI) greater than 29 episodes per hour (mean 52.2 ± 19.0/h) and mild-to-moderate OSA with AHI between 5 and 30 episodes per hour (mean 20.2 ± 7.8/h). A 24-h noninvasive blood pressure monitoring was performed. The standard deviation of mean blood pressure was used as the indicator of blood pressure variability. In patients with severe, compared with mild-to-moderate OSA, a higher mean nocturnal systolic blood pressure (133.2 ± 17.4 mmHg vs. 117.7 ± 31.2 mmHg, p variability (12.1 ± 6.0 vs. 7.6 ± 4.3, p variability (10.5 ± 6.1 vs. 7.3 ± 4.0 p variability (9.1 ± 4.9 mmHg vs. 6.8 ± 3.5 mmHg) were detected. The findings of the study point to increased nocturnal systolic and diastolic arterial blood pressure and blood pressure variability as risk factors of cardiovascular complications in patients with severe OSA.

  13. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Chin, K Y; Panerai, R B

    2013-01-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SD d ) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  14. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Kyriacou, P A; Shafqat, K; Pal, S K

    2007-01-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO 2 ) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO 2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  15. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  16. Central aortic systolic blood pressure can predict prolonged QTc duration better than brachial artery systolic blood pressure in rural community residents.

    Science.gov (United States)

    Huang, Yuqing; Tang, Songtao; Chen, Ji-Yan; Huang, Cheng; Li, Jie; Cai, An-Ping; Feng, Yingqing

    2018-01-01

    Previous studies have suggested that prolonged electrocardiogram QTc duration was independent risk factor for both increased cardiovascular and all-cause mortality, but there was no dating about the relationship between central aortic systolic blood pressure (CASP) and QTc duration. The aim of this study was to analyze the relationship between CASP and QTc duration, and assess whether CASP can predict prolonged QTc duration more than BSBP. A total of 500 patients were enrolled in this study, central and brachial aortic blood pressure and electrocardiogram QTc duration were measured. Pearson correlation was assessed for determining the associations of QTc duration with clinical conditions. Multivariate logistic regression analyses were performed to determine the independent predictor of prolonged QTc duration. Receiver operating characteristic (ROC) curve was used to evaluate the utility of blood pressure for prolonged QTc duration. We found QTc durations were significantly positive with CASP (r = 0.308, p AUC: 0.771 vs. 0.646, p < 0.001) BSBP. Our results suggested that the non-invasive CASP is independently correlated with QTc duration, and CASP can predict prolonged QTc duration more than BSBP.

  17. PULSE WAVE VELOCITY AND CENTRAL AORTIC PRESSURE IN OBESE CHILDREN ACCORDING TO THE NON-INVASIVE ARTERIOGRAPHY RESULTS

    Directory of Open Access Journals (Sweden)

    O. V. Kozhevnikova

    2013-01-01

    Full Text Available The article presents information value of non-invasive arteriography, which reveals early signs of cardiovascular pathology formation in children, using a large number of trials in children. The authors examined predictors of cardiovascular catastrophes’ development, confirmed in adults: aortic wall’s stiffness, central aortic pressure and pulse pressure – that have not been sufficiently studied in children yet. The article shows that the high-technology method of non-invasive arteriography allows revealing changes of these parameters in children on the preclinical stage. It also shows their correlation with body mass index, fatty hepatosis, direct correlation of weight gain with connection of pulse wave velocity and central blood pressure and importance of follow-up evaluation of these parameters. Heterogeneity of the group of obese children in terms of these parameters is a premise for development of individual approach to control and prevention of cardiovascular complications’ development risk in childhood.

  18. Noninvasive microbubble-based pressure measurements: a simulation study

    NARCIS (Netherlands)

    Postema, Michiel; Postema, M.A.B.; Bouakaz, Ayache; de Jong, N.

    2004-01-01

    This paper describes a noninvasive method to measure local hydrostatic pressures in fluid filled cavities. The method is based on the disappearance time of a gas bubble, as the disappearance time is related to the hydrostatic pressure. When a bubble shrinks, its response to ultrasound changes. From

  19. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  20. Diurnal blood pressure changes.

    Science.gov (United States)

    Asayama, Kei; Satoh, Michihiro; Kikuya, Masahiro

    2018-05-23

    The definition of diurnal blood pressure changes varies widely, which can be confusing. Short-term blood pressure variability during a 24-h period and the dipping status of diurnal blood pressure can be captured by ambulatory blood pressure monitoring, and these metrics are reported to have prognostic significance for cardiovascular complications. Morning blood pressure surge also indicates this risk, but its effect may be limited to populations with specific conditions. Meanwhile, the combined use of conventional office blood pressure and out-of-office blood pressure allows us to identify people with white-coat and masked hypertension. Current home devices can measure nocturnal blood pressure during sleep more conveniently than ambulatory monitoring; however, we should pay attention to blood pressure measurement conditions regardless of whether they are in a home, ambulatory, or office setting. The relatively poor reproducibility of diurnal blood pressure changes, including the nocturnal fall of blood pressure, is another underestimated issue to be addressed. Although information on diurnal blood pressure changes is expected to be used more effectively in the future, we should also keep in mind that blood pressure levels have remained central to the primary and secondary prevention of blood pressure-related cardiovascular diseases in clinical practice.

  1. Non-constrained monitoring of systolic blood pressure on a weighing scale

    International Nuclear Information System (INIS)

    Shin, Jae Hyuk; Lee, Kang Moo; Park, Kwang Suk

    2009-01-01

    In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured using three different methods: on the chest using Ag/AgCl electrodes, on the hands using dry electrodes and on the feet also using dry electrodes. For a BP correlated parameter, a time interval parameter, which was defined as the time difference between the ECG R-peak and BCG J-peak, was employed for evaluating and estimating beat-to-beat BP. Under a BP varying experiment with a Valsalva manoeuvre, the R–J intervals were extracted at every beat cycle and a systolic blood pressure (SBP) estimation equation was established using linear regression analysis for each subject. In the case of feet delivered ECG (F-ECG), an ensemble average technique synchronized at the BCG J-peak point was applied to extract the ECG signal from the feet. The performance of the proposed method was evaluated using Finapres, a non-invasive blood pressure measurement system, as a reference BP signal, and a scatter plot was used to find the regression line between the reference values and estimated BPs. A moving-window averaging technique was applied to remove the high-frequency noise in the R–J intervals and was applied to enhance the accuracy of the SBP estimation. For all individuals, the estimated SBP was similar to the measured SBP with a reliable correlation, which makes the proposed method suitable for use in a home healthcare system to monitor blood pressure on a weighing scale at the same time as measuring weight

  2. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    Science.gov (United States)

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  3. Noninvasive beat-to-beat finger arterial pressure monitoring during orthostasis : a comprehensive review of normal and abnormal responses at different ages

    NARCIS (Netherlands)

    van Wijnen, V K; Finucane, C; Harms, M P M; Nolan, H; Freeman, R L; Westerhof, B. E.; Kenny, R A; Ter Maaten, J C; Wieling, W

    2017-01-01

    Over the past 30years, noninvasive beat-to-beat blood pressure (BP) monitoring has provided great insight into cardiovascular autonomic regulation during standing. Although traditional sphygmomanometric measurement of BP may be sufficient for detection of sustained orthostatic hypotension, it fails

  4. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring

    OpenAIRE

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-01-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery–powered electrochemical twin channels (ETCs). The ...

  5. High Blood Pressure

    Science.gov (United States)

    ... normal blood pressure 140/90 or higher is high blood pressure Between 120 and 139 for the top number, ... prehypertension. Prehypertension means you may end up with high blood pressure, unless you take steps to prevent it. High ...

  6. Low Blood Pressure (Hypotension)

    Science.gov (United States)

    ... lowest at night and rises sharply on waking. Blood pressure: How low can you go? What's considered low ... low blood pressure. Medications that can cause low blood pressure Some medications can cause low blood pressure, including: ...

  7. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  8. Hypertension (High Blood Pressure)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Hypertension (High Blood Pressure) KidsHealth / For Teens / Hypertension (High Blood Pressure) What's ... rest temperature diet emotions posture medicines Why Is High Blood Pressure Bad? High blood pressure means a person's heart ...

  9. Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study

    Science.gov (United States)

    Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.

    2002-08-01

    Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.

  10. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  11. Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags.

    Science.gov (United States)

    Buckley, K; Atkins, C G; Chen, D; Schulze, H G; Devine, D V; Blades, M W; Turner, R F B

    2016-03-07

    After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 °C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.

  12. Severe bronchopulmonary dysplasia improved by noninvasive positive pressure ventilation: a case report

    Directory of Open Access Journals (Sweden)

    Mann Christian

    2011-09-01

    Full Text Available Abstract Introduction This is the first report to describe the feasibility and effectiveness of noninvasive positive pressure ventilation in the secondary treatment of bronchopulmonary dysplasia. Case presentation A former male preterm of Caucasian ethnicity delivered at 29 weeks gestation developed severe bronchopulmonary dysplasia. At the age of six months he was in permanent tachypnea and dyspnea and in need of 100% oxygen with a flow of 2.0 L/minute via a nasal cannula. Intermittent nocturnal noninvasive positive pressure ventilation was then administered for seven hours daily. The ventilator was set at a positive end-expiratory pressure of 6 cmH2O, with pressure support of 4 cmH2O, trigger at 1.4 mL/second, and a maximum inspiratory time of 0.7 seconds. Over the course of seven weeks, the patient's maximum daytime fraction of inspired oxygen via nasal cannula decreased from 1.0 to 0.75, his respiratory rate from 64 breaths/minute to 50 breaths/minute and carbon dioxide from 58 mmHg to 44 mmHg. Conclusion Noninvasive positive pressure ventilation may be a novel therapeutic option for established severe bronchopulmonary dysplasia. In the case presented, noninvasive positive pressure ventilation achieved sustained improvement in ventilation and thus prepared our patient for safe home oxygen therapy.

  13. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    Science.gov (United States)

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  14. An Embedded Device for Real-Time Noninvasive Intracranial Pressure Estimation.

    Science.gov (United States)

    Matthews, Jonathan M; Fanelli, Andrea; Heldt, Thomas

    2018-01-01

    The monitoring of intracranial pressure (ICP) is indicated for diagnosing and guiding therapy in many neurological conditions. Current monitoring methods, however, are highly invasive, limiting their use to the most critically ill patients only. Our goal is to develop and test an embedded device that performs all necessary mathematical operations in real-time for noninvasive ICP (nICP) estimation based on a previously developed model-based approach that uses cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) waveforms. The nICP estimation algorithm along with the required preprocessing steps were implemented on an NXP LPC4337 microcontroller unit (MCU). A prototype device using the MCU was also developed, complete with display, recording functionality, and peripheral interfaces for ABP and CBFV monitoring hardware. The device produces an estimate of mean ICP once per minute and performs the necessary computations in 410 ms, on average. Real-time nICP estimates differed from the original batch-mode MATLAB implementation of theestimation algorithm by 0.63 mmHg (root-mean-square error). We have demonstrated that real-time nICP estimation is possible on a microprocessor platform, which offers the advantages of low cost, small size, and product modularity over a general-purpose computer. These attributes take a step toward the goal of real-time nICP estimation at the patient's bedside in a variety of clinical settings.

  15. Continuous estimates of dynamic cerebral autoregulation: influence of non-invasive arterial blood pressure measurements

    International Nuclear Information System (INIS)

    Panerai, R B; Smith, S M; Rathbone, W E; Samani, N J; Sammons, E L; Bentley, S; Potter, J F

    2008-01-01

    Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result of artefacts in methods of measurement, such as the use of non-invasive measurements of BP in the finger. In 27 subjects (61 ± 11 years old) undergoing coronary artery angioplasty, BP was continuously recorded at rest with the Finapres device and in the ascending aorta (Millar catheter, BP AO ), together with bilateral transcranial Doppler ultrasound in the middle cerebral artery, surface ECG and transcutaneous CO 2 . Dynamic CA was expressed by the autoregulation index (ARI), ranging from 0 (absence of CA) to 9 (best CA). Time-varying, continuous estimates of ARI (ARI(t)) were obtained with an autoregressive moving-average (ARMA) model applied to a 60 s sliding data window. No significant differences were observed in the accuracy and precision of ARI(t) between estimates derived from the Finapres and BP AO . Highly significant correlations were obtained between ARI(t) estimates from the right and left middle cerebral artery (MCA) (Finapres r = 0.60 ± 0.20; BP AO r = 0.56 ± 0.22) and also between the ARI(t) estimates from the Finapres and BP AO (right MCA r = 0.70 ± 0.22; left MCA r = 0.74 ± 0.22). Surrogate data showed that ARI(t) was highly sensitive to the presence of noise in the CBFV signal, with both the bias and dispersion of estimates increasing for lower values of ARI(t). This effect could explain the sudden drops of ARI(t) to zero as reported previously. Simulated sudden changes in ARI(t) can be detected by the Finapres, but the bias and variability of estimates also increase for lower values of ARI. In summary, the Finapres does not distort time-varying estimates of dynamic CA obtained with a sliding window combined with an ARMA model

  16. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events

    DEFF Research Database (Denmark)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke

    2017-01-01

    Aims: To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Methods...... and results: A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events....... Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0...

  17. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events.

    Science.gov (United States)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke; Torp-Pedersen, Christian

    2017-11-21

    To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0.01% (-0.3%; 0.1%) for cardiovascular mortality and -0.1% (-1.1%; 0.5%) for cardiovascular events. The difference in AUC (95% confidence interval) was 0.65% (0.22-1.08%) for cardiovascular mortality and 1.33% (0.83-1.84%) for cardiovascular events. Comparing daytime and night-time blood pressure, the median difference in 10-year risks was 0.002% (-0.1%; 0.1%) for cardiovascular mortality and -0.01% (-0.5%; 0.2%) for cardiovascular events. The difference in AUC was 0.10% (-0.08 to 0.29%) for cardiovascular mortality and 0.15% (-0.06 to 0.35%) for cardiovascular events. Ten-year predictions obtained from ambulatory blood pressure are similar to predictions from office blood pressure. Night-time blood pressure does not improve 10-year predictions obtained from daytime measurements. For an otherwise healthy population sufficient prognostic accuracy of cardiovascular risks can be achieved with office blood pressure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  18. Noninvasive measurement of an index of renal blood flow

    International Nuclear Information System (INIS)

    Powers, T.A.; Rees, R.S.; Bowen, R.D.

    1983-01-01

    A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compartmental analysis principles. There is good correlation between renal blood flow estimated by this technique and that determined by microsphere injection

  19. Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors

    International Nuclear Information System (INIS)

    Baek, Hyun Jae; Kim, Ko Keun; Kim, Jung Soo; Lee, Boreom; Park, Kwang Suk

    2010-01-01

    A new method of blood pressure (BP) estimation using multiple regression with pulse arrival time (PAT) and two confounding factors was evaluated in clinical and unconstrained monitoring situations. For the first analysis with clinical data, electrocardiogram (ECG), photoplethysmogram (PPG) and invasive BP signals were obtained by a conventional patient monitoring device during surgery. In the second analysis, ECG, PPG and non-invasive BP were measured using systems developed to obtain data under conditions in which the subject was not constrained. To enhance the performance of BP estimation methods, heart rate (HR) and arterial stiffness were considered as confounding factors in regression analysis. The PAT and HR were easily extracted from ECG and PPG signals. For arterial stiffness, the duration from the maximum derivative point to the maximum of the dicrotic notch in the PPG signal, a parameter called TDB, was employed. In two experiments that normally cause BP variation, the correlation between measured BP and the estimated BP was investigated. Multiple-regression analysis with the two confounding factors improved correlation coefficients for diastolic blood pressure and systolic blood pressure to acceptable confidence levels, compared to existing methods that consider PAT only. In addition, reproducibility for the proposed method was determined using constructed test sets. Our results demonstrate that non-invasive, non-intrusive BP estimation can be obtained using methods that can be applied in both clinical and daily healthcare situations

  20. Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors.

    Science.gov (United States)

    Baek, Hyun Jae; Kim, Ko Keun; Kim, Jung Soo; Lee, Boreom; Park, Kwang Suk

    2010-02-01

    A new method of blood pressure (BP) estimation using multiple regression with pulse arrival time (PAT) and two confounding factors was evaluated in clinical and unconstrained monitoring situations. For the first analysis with clinical data, electrocardiogram (ECG), photoplethysmogram (PPG) and invasive BP signals were obtained by a conventional patient monitoring device during surgery. In the second analysis, ECG, PPG and non-invasive BP were measured using systems developed to obtain data under conditions in which the subject was not constrained. To enhance the performance of BP estimation methods, heart rate (HR) and arterial stiffness were considered as confounding factors in regression analysis. The PAT and HR were easily extracted from ECG and PPG signals. For arterial stiffness, the duration from the maximum derivative point to the maximum of the dicrotic notch in the PPG signal, a parameter called TDB, was employed. In two experiments that normally cause BP variation, the correlation between measured BP and the estimated BP was investigated. Multiple-regression analysis with the two confounding factors improved correlation coefficients for diastolic blood pressure and systolic blood pressure to acceptable confidence levels, compared to existing methods that consider PAT only. In addition, reproducibility for the proposed method was determined using constructed test sets. Our results demonstrate that non-invasive, non-intrusive BP estimation can be obtained using methods that can be applied in both clinical and daily healthcare situations.

  1. Differences in blood pressure by measurement technique in neurocritically ill patients: A technological assessment.

    Science.gov (United States)

    Lele, Abhijit V; Wilson, Daren; Chalise, Prabhakar; Nazzaro, Jules; Krishnamoorthy, Vijay; Vavilala, Monica S

    2018-01-01

    Blood pressure data may vary by measurement technique. We performed a technological assessment of differences in blood pressure measurement between non-invasive blood pressure (NIBP) and invasive arterial blood pressure (ABP) in neurocritically ill patients. After IRB approval, a prospective observational study was performed to study differences in systolic blood pressure (SBP), mean arterial pressure (MAP), and cerebral perfusion pressure (CPP) values measured by NIBP arm, ABP at level of the phlebostatic axis (ABP heart) and ABP at level of the external auditory meatus (ABP brain) at 30 and 45-degree head of bed elevation (HOB) using repeated measure analysis of covariance and correlation coefficients. Overall, 168 patients were studied with median age of 57 ± 15 years, were mostly female (57%), with body mass index ≤30 (66%). Twenty-three percent (n = 39) had indwelling intracranial pressure monitors, and 19.7% (n = 33) received vasoactive agents. ABP heart overestimated ABP brain for SBP (11.5 ± 2.7 mmHg, p ABP heart overestimated NIBP arm for SBP (8 ± 1.5 mmHg, p ABP heart overestimates MAP compared to ABP brain and NIBP arm. Using ABP heart data overestimates CPP and may be responsible for not achieving SBP, MAP or CPP targets aimed at the brain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Application of optical coherence tomography for noninvasive blood glucose monitoring during hyperglycemia

    Science.gov (United States)

    Larin, Kirill V.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2003-10-01

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from Diabetes Mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for chemical analysis. Recently we proposed to use optical coherence tomography (OCT) for continuous noninvasive blood glucose sensing through skin. In this paper we tested the OCT technique for noninvasive monitoring of blood glucose concentration in lip tissue of New Zealand rabbits and Yucatan micropigs during glucose clamping experiments. Obtained results show good agreement with results obtained in skin studies, good correlation of changes in the OCT signal slope measured at the depth of 250 to 500 μm with changes in blood glucose concentration, and higher stability of the OCT data points than that obtained from skin.

  3. High Blood Pressure Facts

    Science.gov (United States)

    ... Stroke Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN High Blood Pressure Facts Recommend on Facebook Tweet Share Compartir On ... Top of Page CDC Fact Sheets Related to High Blood Pressure High Blood Pressure Pulmonary Hypertension Heart Disease Signs ...

  4. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... Print Page Text Size: A A A Listen High Blood Pressure (Hypertension) Nearly 1 in 3 American adults has ... weight. How Will I Know if I Have High Blood Pressure? High blood pressure is a silent problem — you ...

  5. Influence of short-term blood pressure variability on blood pressure determinations

    NARCIS (Netherlands)

    Bos, W. J.; van Goudoever, J.; van Montfrans, G. A.; Wesseling, K. H.

    1992-01-01

    To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial

  6. Optical sensor technology for a noninvasive medical blood diagnosis

    Science.gov (United States)

    Kraitl, Jens; Ewald, Hartmut; Gehring, Hartmut

    2007-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) and is used for a measurement of blood components. The fact that the absorption-coefficients μ a and scattering-coefficients μ s for blood differ at difference wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Deferrals between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods.

  7. High Blood Pressure (Hypertension) (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Hypertension (High Blood Pressure) KidsHealth / For Parents / Hypertension (High Blood Pressure) What's ... High Blood Pressure) Treated? Print What Is Hypertension (High Blood Pressure)? Blood pressure is the pressure of blood against ...

  8. ORANGE JUICE AND BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    M. F. VALIM

    2009-01-01

    Full Text Available

    Blood pressure is the force of blood against artery walls. It is measured in millimeters of mercury (mm Hg and recorded as two numbers: systolic pressure (as the heart contracts over diastolic pressure (as the heart relaxes between beats. High blood pressure (hypertension is defined as chronically elevated high blood pressure, with systolic blood pressure (SBP of 140 mm Hg or greater, and diastolic blood pressure (DBP of 90 mm Hg or greater. High blood pressure (HBP, smoking, abnormal blood lipid levels, obesity and diabetes are risk factors for coronary heart disease, the leading cause of death in the US. Lifestyle modifications such as engaging in regular physical activity, quitting smoking and eating a healthy diet (limiting intake of saturated fat and sodium and increasing consumption of fiber, fruits and vegetables are advocated for the prevention, treatment, and control of HBP. As multiple factors influence blood pressure, the effects of each factor are typically modest, particularly in normotensive subjects, yet the combined effects can be substantial. Nutrition plays an important role in influencing blood pressure. Orange juice should be included as part of any low sodium diet and/or any blood pressure reducing eating plan, as it is sodium free, fat-free and can help meet recommended levels of potassium intake that may contribute to lower BP.

  9. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  10. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  11. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  12. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  13. Blood Pressure Medicines

    Science.gov (United States)

    High blood pressure, also called hypertension, usually has no symptoms. But it can cause serious problems such as stroke, heart ... kidney failure. If you cannot control your high blood pressure through lifestyle changes such as losing weight and ...

  14. Orthostatic circulatory control in the elderly evaluated by non-invasive continuous blood pressure measurement

    NARCIS (Netherlands)

    Imholz, B. P.; Dambrink, J. H.; Karemaker, J. M.; Wieling, W.

    1990-01-01

    1. Continuous orthostatic responses of blood pressure and heart rate were measured in 40 healthy and active elderly subjects over 70 years of age in order to assess the time course and rapidity of orthostatic cardiovascular adaptation in old age. 2. During the first 30 s (initial phase) the effects

  15. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  16. Non-invasive blood glucose monitor based on spectroscopy using a smartphone.

    Science.gov (United States)

    Dantu, Vishnu; Vempati, Jagannadh; Srivilliputhur, Srinivasan

    2014-01-01

    Development of a novel method for non-invasive measurement of blood glucose concentration using smartphone is discussed. Our research work has three major contributions to society and science. First, we modified and extended the Beer-Lambert's law in physics to accommodate for multiple wavelengths. This extension can aid researchers who wish to perform optical spectroscopy. Second, we successfully developed a creative and non-invasive way for diabetic patients to measure glucose levels via a smartphone. Researchers and chemists can now use their smartphones to determine the absorbance and, therefore, concentration of a chemical. Third, we created an inexpensive way to perform optical spectroscopy by using a smartphone. Monitoring blood glucose using a smartphone application that simply uses equipment already available on smartphones will improve the lives of diabetic patients who can continuously check their blood glucose levels while avoiding the current inconvenient, unhygienic, and costly invasive glucose meters.

  17. KETAMINE-MEDETOMIDINE AND KETAMINE-MEDETOMIDINE-MIDAZOLAM ANESTHESIA IN CAPTIVE CHEETAHS (ACINONYX JUBATUS)-COMPARISON OF BLOOD PRESSURE AND KIDNEY BLOOD FLOW.

    Science.gov (United States)

    Stagegaard, Julia; Hørlyck, Arne; Hydeskov, Helle B; Bertelsen, Mads F

    2017-06-01

    Six clinically healthy captive cheetahs ( Acinonyx jubatus ) were anesthetized twice using two different drug combinations to investigate if blood pressure and kidney blood flow are affected by medetomidine dosage. Protocol KM (2.0 mg/kg ketamine and 0.05 mg/kg medetomidine) was compared with protocol KMM (2.0 mg/kg ketamine, 0.02 mg/kg medetomidine, and 0.1 mg/kg midazolam). Heart rate (HR), respiratory rate (RR), body temperature, end-tidal carbon dioxide pressure (ETCO 2 ), and anesthetic depth were monitored every 10 min. Noninvasive mean (MAP), systolic (SAP), and diastolic (DAP) arterial blood pressure were measured, and Duplex Doppler ultrasonography was performed on the kidneys. The mean arterial resistive index (RI) was determined and the pulse pressure index (PPI) was calculated, as indicators for kidney blood flow. There were no significant differences in induction and recovery times. MAP was significantly higher with KM than KMM at 35 min, and in both protocols decreased significantly after atipamezole administration. DAP was significantly higher at 25 and 35 min in animals anesthetized with KM; it also decreased significantly with both protocols after atipamezole administration. The PPI was significantly lower throughout the procedure with KM, and with both protocols increased significantly after atipamezole administration. Both the higher blood pressure and the reduced PPI with KM were likely a direct effect of the higher medetomidine dosage, and these findings indicate that lower medetomidine dosages might reduce hypertension and lead to a better PPI in cheetah immobilization.

  18. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  19. Respiratory sinus arrhythmia stabilizes mean arterial blood pressure at high-frequency interval in healthy humans.

    Science.gov (United States)

    Elstad, Maja; Walløe, Lars; Holme, Nathalie L A; Maes, Elke; Thoresen, Marianne

    2015-03-01

    Arterial blood pressure variations are an independent risk factor for end organ failure. Respiratory sinus arrhythmia (RSA) is a sign of a healthy cardiovascular system. However, whether RSA counteracts arterial blood pressure variations during the respiratory cycle remains controversial. We restricted normal RSA with non-invasive intermittent positive pressure ventilation (IPPV) to test the hypothesis that RSA normally functions to stabilize mean arterial blood pressure. Ten young volunteers were investigated during metronome-paced breathing and IPPV. Heart rate (ECG), mean arterial blood pressure and left stroke volume (finger arterial pressure curve) and right stroke volume (pulsed ultrasound Doppler) were recorded, while systemic and pulmonary blood flow were calculated beat-by-beat. Respiratory variations (high-frequency power, 0.15-0.40 Hz) in cardiovascular variables were estimated by spectral analysis. Phase angles and correlation were calculated by cross-spectral analysis. The magnitude of RSA was reduced from 4.9 bpm(2) (95% CI 3.0, 6.2) during metronome breathing to 2.8 bpm(2) (95% CI 1.1, 5.0) during IPPV (p = 0.03). Variations in mean arterial blood pressure were greater (2.3 mmHg(2) (95% CI 1.4, 3.9) during IPPV than during metronome breathing (1.0 mmHg(2) [95% CI 0.7, 1.3]) (p = 0.014). Respiratory variations in right and left stroke volumes were inversely related in the respiratory cycle during both metronome breathing and IPPV. RSA magnitude is lower and mean arterial blood pressure variability is greater during IPPV than during metronome breathing. We conclude that in healthy humans, RSA stabilizes mean arterial blood pressure at respiratory frequency.

  20. Clinical study on influences of enteric coated aspirin on blood pressure and blood pressure variability.

    Science.gov (United States)

    Ji, A-L; Chen, W-W; Huang, W-J

    2016-12-01

    We investigated the effects of oral administration of enteric coated aspirin (ASA) on blood pressure and blood pressure variability of hypertension patients before sleep. We observed 150 hypertension cases, classified as Grade 1-2, from September 2006 to March 2008. They are divided into a control group with 30 cases, ASA I group with 60 cases and ASA II group with 60 cases randomly. Subjects in the control group had proper diets, were losing weight, exercising and maintaining a healthy mentality and were taking 30 mg Adalat orally once a day. Based on the treatment of control group, patients in ASA I group were administered 0.1 g Bayaspirin (produced by Bayer Company) at drought in the morning. Also, based on the treatment of control group, patients in ASA II group were administered 0.1 g Bayaspirin at draught before sleep. The course of treatment is 3 months and then after the treatment, decreasing blood pressure and blood pressure variability conditions in three groups will be compared. Through the comparison of ASA II group with the control group, they have differences in terms of systolic blood pressure (SBP), diastolic blood pressure (DBP), decreasing range of blood pressure and blood pressure variability (p sleep has synergistic effects on decreasing blood pressure of hypertension patients and improving blood pressure variability.

  1. Update: Non-Invasive Positive Pressure Ventilation in Chronic Respiratory Failure Due to COPD.

    Science.gov (United States)

    Altintas, Nejat

    2016-01-01

    Long-term non-invasive positive pressure ventilation (NPPV) has widely been accepted to treat chronic hypercapnic respiratory failure arising from different etiologies. Although the survival benefits provided by long-term NPPV in individuals with restrictive thoracic disorders or stable, slowly-progressing neuromuscular disorders are overwhelming, the benefits provided by long-term NPPV in patients with chronic obstructive pulmonary disease (COPD) remain under question, due to a lack of convincing evidence in the literature. In addition, long-term NPPV reportedly failed in the classic trials to improve important physiological parameters such as arterial blood gases, which might serve as an explanation as to why long-term NPPV has not been shown to substantially impact on survival. However, high intensity NPPV (HI-NPPV) using controlled NPPV with the highest possible inspiratory pressures tolerated by the patient has recently been described as a new and promising approach that is well-tolerated and is also capable of improving important physiological parameters such as arterial blood gases and lung function. This clearly contrasts with the conventional approach of low-intensity NPPV (LI-NPPV) that uses considerably lower inspiratory pressures with assisted forms of NPPV. Importantly, HI-NPPV was very recently shown to be superior to LI-NPPV in terms of improved overnight blood gases, and was also better tolerated than LI-NPPV. Furthermore, HI-NPPV, but not LI-NPPV, improved dyspnea, lung function and disease-specific aspects of health-related quality of life. A recent study showed that long-term treatment with NPPV with increased ventilatory pressures that reduced hypercapnia was associated with significant and sustained improvements in overall mortality. Thus, long-term NPPV seems to offer important benefits in this patient group, but the treatment success might be dependent on effective ventilatory strategies.

  2. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    Science.gov (United States)

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.

  3. [Domiciliary noninvasive positive pressure ventilation in chronic alveolar hypoventilation].

    Science.gov (United States)

    Casas, J P; Robles, A M; Pereyra, M A; Abbona, H L; López, A M

    2000-01-01

    Effectiveness of treatment with domiciliary nocturnal noninvasive positive pressure ventilation is analyzed in a group of patients with chronic alveolar hypoventilation of different etiologies. It was applied with two levels of pressure (BiPAP) via nasal mask. Criteria for evaluation were symptomatology and improvement in gas exchange. Data were analyzed by Student t tests. A total of 13 patients were included, mean age 55.7 range 20 to 76 years (5 male 8 female). Main diagnosis was tuberculosis in 6, four of them having had surgical procedure (thoracoplasty 2, frenicectomy 1 and neumonectomy 1), myopathy 3 (myasthenia gravis 1, muscular dystrophy 1 and diaphragmatic paralysis 1), obesity-hypoventilation syndrome 1, escoliosis 1, bronchiectasis 1 and cystic fibrosis 1. These last two patients were on waiting list for lung transplantation. At the moment of consultation, the symptoms were: dysnea 13/13 (100%), astenia 13/13 (100%), hypersomnolency 10/13 (77%), cephalea 9/13 (69%), leg edema 6/13 (46%), loss of memory 6/13 (46%). Regarding gas exchange, they showed hypoxemia and hypercapnia. Mean follow up was of 2.2 years (range 6 months to 4 years). Within the year, all 13 patients became less dyspneic. Astenia, hypersomnolency, cephalea, leg edema and memory loss disappeared. Improvement in gas exchange was: PaO2/FiO2 from 269 +/- 65.4 (basal) to 336.7 +/- 75.3 post-treatment (p = 0.0018). PaCO2 from 70.77 +/- 25.48 mmHg (basal) to 46.77 +/- 8.14 mmHg (p = 0.0013). Ventilatory support was discontinued en 5 patients: three because of pneumonia requiring intubation and conventional mechanical ventilation, two of them died and one is still with tracheostomy; One patient with bronchiectasis and one with cystic fibrosis were transplanted. The remaining eight patients are stable. In conclusion, chronic alveolar hypoventilation can be effectively treated with domiciliary nocturnal noninvasive ventilation. Long term improvement in symptomatology and arterial blood gases

  4. Non-invasive nuclear device for communicating pressure inside a body to the exterior thereof

    International Nuclear Information System (INIS)

    Fleischmann, L.W.; Meyer, G.A.; Hittman, F.; Lyon, W.C.; Hayes, W.H. Jr.

    1979-01-01

    The need for a non-invasive technique for measuring the pressure in body cavities of animals or humans is recognized as highly desirable for continuous or intermittent monitoring of body conditions. The non-invasive nuclear device of the present invention is fully implantable and is fully capable of communicating pressure inside a body to the exterior to allow readout non-invasively. In its preferred form, the invention includes a housing for subcutaneous implantation with the radioactive source. An urging means such as a bellows is provided in the housing interior. The fluid pressure from a fluid pressure sensing device within the body is transmitted to the housing interior by means of a pressure-limiting fluid through a conduit. This causes the radioactive source to move against the force out of the initial or repose shielded relationship causing a proportional increase in pressure in the body portion being monitored. The radioactive output from the radioactive source corresponds to the magnitude of the pressure within the body. The housing may be securely mounted on a supporting portion of the body and the mounting serves as a radiation shield for the body. (JTA)

  5. Cuff-less PPG based continuous blood pressure monitoring: a smartphone based approach.

    Science.gov (United States)

    Gaurav, Aman; Maheedhar, Maram; Tiwari, Vijay N; Narayanan, Rangavittal

    2016-08-01

    Cuff-less estimation of systolic (SBP) and diastolic (DBP) blood pressure is an efficient approach for non-invasive and continuous monitoring of an individual's vitals. Although pulse transit time (PTT) based approaches have been successful in estimating the systolic and diastolic blood pressures to a reasonable degree of accuracy, there is still scope for improvement in terms of accuracies. Moreover, PTT approach requires data from sensors placed at two different locations along with individual calibration of physiological parameters for deriving correct estimation of systolic and diastolic blood pressure (BP) and hence is not suitable for smartphone deployment. Heart Rate Variability is one of the extensively used non-invasive parameters to assess cardiovascular autonomic nervous system and is known to be associated with SBP and DBP indirectly. In this work, we propose a novel method to extract a comprehensive set of features by combining PPG signal based and Heart Rate Variability (HRV) related features using a single PPG sensor. Further, these features are fed into a DBP feedback based combinatorial neural network model to arrive at a common weighted average output of DBP and subsequently SBP. Our results show that using this current approach, an accuracy of ±6.8 mmHg for SBP and ±4.7 mmHg for DBP is achievable on 1,750,000 pulses extracted from a public database (comprising 3000 people). Since most of the smartphones are now equipped with PPG sensor, a mobile based cuff-less BP estimation will enable the user to monitor their BP as a vital parameter on demand. This will open new avenues towards development of pervasive and continuous BP monitoring systems leading to an early detection and prevention of cardiovascular diseases.

  6. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  7. Types of Blood Pressure Medications

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Types of Blood Pressure Medications Updated:Nov 6,2017 Prescription blood pressure ... This content was last reviewed October 2017. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  8. Controlling your high blood pressure

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000101.htm Controlling your high blood pressure To use the sharing features on this page, ... JavaScript. Hypertension is another term used to describe high blood pressure. High blood pressure can lead to: Stroke Heart ...

  9. Evaluation of four non-invasive methods for examination and characterization of pressure ulcers

    DEFF Research Database (Denmark)

    Andersen, E.S.; Karlsmark, T.

    2008-01-01

    Background: Pressure ulcers are globally of major concern and there is need for research in the pathogenesis for early intervention. Early studies have suggested existence of a hypo-echogenic subepidermal layer at the location of pressure ulcers, visualized by ultrasound scans. As a continuation......, we here report on usability of four non-invasive techniques for evaluation of pressure ulcers. Methods: Fifteen pressure ulcers in stage 0-IV were examined using four different non-invasive techniques [redness index, skin temperature, skin elasticity (i.e. retraction time), and ultrasound scanning...... at all pressure ulcers, but none at the reference points. The skin retraction time was often higher at the location of a pressure ulcer than at the reference location. We found no correlation between the stage of the ulcers and temperature, redness index, subepidermal layer thickness, or retraction time...

  10. Comparison of an implantable telemetry device and an oscillometric monitor for measurement of blood pressure in anaesthetized and unrestrained green iguanas (Iguana iguana).

    Science.gov (United States)

    Chinnadurai, Sathya K; DeVoe, Ryan; Koenig, Amie; Gadsen, Nadia; Ardente, Amanda; Divers, Stephen J

    2010-09-01

    The objective of this study was to compare an implanted direct blood pressure monitor and a non-invasive oscillometric unit for use in anesthetized and awake green iguanas. Prospective experimental trial. Four male and four female adult green iguanas (Iguana iguana) weighing 1833 +/- 534 g. For each animal, the carotid artery was surgically exposed and the catheter tip of the pressure transducer was placed in the aortic arch. Non-invasive blood pressure was measured using a cuff over the left femoral region. Pulse rate, respiratory rate and arterial blood pressure (ABP) measurements were taken every 5 minutes. Direct ABP measurements consisted of recording numerical values and graphic output. Simultaneous direct and indirect measurements were repeated in awake animals. The oscillometric device failed to provide a reading in over 80% of attempts, and failed to provide readings that correlated with direct measurements. The implanted direct transducer was capable of detecting blood pressures throughout all ABP ranges examined. The implantable transducer was a reliable means of determining blood pressure in this study, while the oscillometric device was unreliable and often failed to provide any reading. We do not recommend using the oscillometric device as described in a research or clinical setting for green iguanas. The advantages of an implantable device include the ability to monitor awake and anesthetized subjects remotely and continuously. These monitors are small, biocompatible and function across a wide range of ABP.

  11. Noninvasive calculation of the aortic blood pressure waveform from the flow velocity waveform: a proof of concept.

    Science.gov (United States)

    Vennin, Samuel; Mayer, Alexia; Li, Ye; Fok, Henry; Clapp, Brian; Alastruey, Jordi; Chowienczyk, Phil

    2015-09-01

    Estimation of aortic and left ventricular (LV) pressure usually requires measurements that are difficult to acquire during the imaging required to obtain concurrent LV dimensions essential for determination of LV mechanical properties. We describe a novel method for deriving aortic pressure from the aortic flow velocity. The target pressure waveform is divided into an early systolic upstroke, determined by the water hammer equation, and a diastolic decay equal to that in the peripheral arterial tree, interposed by a late systolic portion described by a second-order polynomial constrained by conditions of continuity and conservation of mean arterial pressure. Pulse wave velocity (PWV, which can be obtained through imaging), mean arterial pressure, diastolic pressure, and diastolic decay are required inputs for the algorithm. The algorithm was tested using 1) pressure data derived theoretically from prespecified flow waveforms and properties of the arterial tree using a single-tube 1-D model of the arterial tree, and 2) experimental data acquired from a pressure/Doppler flow velocity transducer placed in the ascending aorta in 18 patients (mean ± SD: age 63 ± 11 yr, aortic BP 136 ± 23/73 ± 13 mmHg) at the time of cardiac catheterization. For experimental data, PWV was calculated from measured pressures/flows, and mean and diastolic pressures and diastolic decay were taken from measured pressure (i.e., were assumed to be known). Pressure reconstructed from measured flow agreed well with theoretical pressure: mean ± SD root mean square (RMS) error 0.7 ± 0.1 mmHg. Similarly, for experimental data, pressure reconstructed from measured flow agreed well with measured pressure (mean RMS error 2.4 ± 1.0 mmHg). First systolic shoulder and systolic peak pressures were also accurately rendered (mean ± SD difference 1.4 ± 2.0 mmHg for peak systolic pressure). This is the first noninvasive derivation of aortic pressure based on fluid dynamics (flow and wave speed) in the

  12. Heritability of blood pressure traits and the genetic contribution to blood pressure variance explained by four blood-pressure-related genes.

    NARCIS (Netherlands)

    Rijn, M.J. van; Schut, A.F.; Aulchenko, Y.S.; Deinum, J.; Sayed-Tabatabaei, F.A.; Yazdanpanah, M.; Isaacs, A.; Axenovich, T.I.; Zorkoltseva, I.V.; Zillikens, M.C.; Pols, H.A.; Witteman, J.C.; Oostra, B.A.; Duijn, C.M. van

    2007-01-01

    OBJECTIVE: To study the heritability of four blood pressure traits and the proportion of variance explained by four blood-pressure-related genes. METHODS: All participants are members of an extended pedigree from a Dutch genetically isolated population. Heritability and genetic correlations of

  13. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    Science.gov (United States)

    Groen, Maarten S.; Wu, Kai; Brookhuis, Robert A.; van Houwelingen, Marc J.; Brouwer, Dannis M.; Lötters, Joost C.; Wiegerink, Remco J.

    2014-12-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch.

  14. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    International Nuclear Information System (INIS)

    Groen, Maarten S; Wu, Kai; Brookhuis, Robert A; Lötters, Joost C; Wiegerink, Remco J; Van Houwelingen, Marc J; Brouwer, Dannis M

    2014-01-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch. (paper)

  15. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  16. Serotonin and Blood Pressure Regulation

    Science.gov (United States)

    Morrison, Shaun F.; Davis, Robert Patrick; Barman, Susan M.

    2012-01-01

    5-Hydroxytryptamine (5-HT; serotonin) was discovered more than 60 years ago as a substance isolated from blood. The neural effects of 5-HT have been well investigated and understood, thanks in part to the pharmacological tools available to dissect the serotonergic system and the development of the frequently prescribed selective serotonin-reuptake inhibitors. By contrast, our understanding of the role of 5-HT in the control and modification of blood pressure pales in comparison. Here we focus on the role of 5-HT in systemic blood pressure control. This review provides an in-depth study of the function and pharmacology of 5-HT in those tissues that can modify blood pressure (blood, vasculature, heart, adrenal gland, kidney, brain), with a focus on the autonomic nervous system that includes mechanisms of action and pharmacology of 5-HT within each system. We compare the change in blood pressure produced in different species by short- and long-term administration of 5-HT or selective serotonin receptor agonists. To further our understanding of the mechanisms through which 5-HT modifies blood pressure, we also describe the blood pressure effects of commonly used drugs that modify the actions of 5-HT. The pharmacology and physiological actions of 5-HT in modifying blood pressure are important, given its involvement in circulatory shock, orthostatic hypotension, serotonin syndrome and hypertension. PMID:22407614

  17. Studies Comparing Ambulatory Blood Pressure and Home Blood Pressure on Cardiovascular Disease and Mortality Outcomes: A Systematic Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Ambulatory blood pressure monitoring (ABPM) is more commonly recommended for assessing out-of-clinic blood pressure than home blood pressure monitoring (HBPM). We conducted a systematic review to examine whether ABPM or HBPM is more strongly associated with cardiovascular disease events and/or mortality. Of 1,007 abstracts published through July 20, 2015, nine articles, reporting results from seven cohorts, were identified. After adjustment for blood pressure on HBPM, blood pressure on ABPM was associated with an increased risk of outcomes in two of four cohorts for systolic blood pressure and two of three cohorts for diastolic blood pressure. After adjustment for blood pressure on ABPM, systolic blood pressure on HBPM was associated with outcomes in zero of three cohorts; an association was present in one of two cohorts for diastolic blood pressure on HBPM. There is a lack of strong empiric evidence supporting ABPM or HBPM over the other approach for predicting cardiovascular events or mortality. PMID:26822864

  18. Effects of endurance training on blood pressure, blood pressure-regulating mechanisms, and cardiovascular risk factors.

    Science.gov (United States)

    Cornelissen, Véronique A; Fagard, Robert H

    2005-10-01

    Previous meta-analyses of randomized controlled trials on the effects of chronic dynamic aerobic endurance training on blood pressure reported on resting blood pressure only. Our aim was to perform a comprehensive meta-analysis including resting and ambulatory blood pressure, blood pressure-regulating mechanisms, and concomitant cardiovascular risk factors. Inclusion criteria of studies were: random allocation to intervention and control; endurance training as the sole intervention; inclusion of healthy sedentary normotensive or hypertensive adults; intervention duration of > or =4 weeks; availability of systolic or diastolic blood pressure; and publication in a peer-reviewed journal up to December 2003. The meta-analysis involved 72 trials, 105 study groups, and 3936 participants. After weighting for the number of trained participants and using a random-effects model, training induced significant net reductions of resting and daytime ambulatory blood pressure of, respectively, 3.0/2.4 mm Hg (Phypertensive study groups (-6.9/-4.9) than in the others (-1.9/-1.6; Pendurance training decreases blood pressure through a reduction of vascular resistance, in which the sympathetic nervous system and the renin-angiotensin system appear to be involved, and favorably affects concomitant cardiovascular risk factors.

  19. High blood pressure - children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007696.htm High blood pressure - children To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  20. High blood pressure - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007329.htm High blood pressure - infants To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  1. Pulmonary capillary wedge pressure, as inferred from lung areas in gated blood-pool scintigrams: concise communication

    International Nuclear Information System (INIS)

    Urbina, A.; Okada, R.D.; Palacios, I.; Osbakken, M.; Strauss, H.W.

    1981-01-01

    To determine whether the apex-to-base distribution of pulmonary blood volume, as obtained from gated cardiac blood-pool scans, could be used as a noninvasive method to estimate mean pulmonary capillary wedge pressure (PCWP), gated blood-pool scans were analyzed in 77 patients who also had PCWP measurements at cardiac catheterization. Ten of these patients had gated cardiac blood-pool scans and PCWP measurements both at rest and during exercise. The apex-to-base distribution of pulmonary blood volume was determined from the end-systolic frame of the left anterior oblique view by placing equal-sized regions of interest over the apex and base of the right lung. The ratio of apex counts over base counts (A/B ratio) was considered abnormal if greater than unity. The mean A/B ratio was 1.15 +/- 0.27 (1 s.d.) for the 32 studies associated with an abnormal mean PCWP (greater than 12 mm Hg). The mean A/B ratio was 0.85 +/- 0.23 for the 55 studies associated with a normal mean PCWP (p less than 0.01 comparing normal group with abnormal). The sensitivity of the A/B ratio for a mean PCWP greater than 12 mm Hg was 81%R (26/32). The specificity of the A/B ratio for a mean PCWP greater than or equal to 12 mm Hg was 89% (49/55). Thus, noninvasive determination of the pulmonary apex-to-base ratio from gated cardiac blood-pool scans appears to differentiate subjects with normal and abnormal mean pulmonary capillary wedge pressures

  2. Noninvasive prediction of left ventricular end-diastolic pressure in patients with coronary artery disease and preserved ejection fraction.

    Science.gov (United States)

    Abd-El-Aziz, Tarek A

    2012-01-01

    The aim of this study was to compare 3 different available methods for estimating left ventricular end-diastolic pressure (LVEDP) noninvasively in patients with coronary artery disease and preserved left ventricular ejection fraction (EF). We used 3 equations for noninvasive estimation of LVEDP: The equation of Mulvagh et al., LVEDP(1) = 46 - 0.22 (IVRT) - 0.10 (AFF) - 0.03 (DT) - (2 ÷ E/A) + 0.05 MAR; the equation of Stork et al., LVEDP(2) = 1.06 + 15.15 × Ai/Ei; and the equation of Abd-El-Aziz, LVEDP(3) = [0.54 (MABP) × (1 - EF)] - 2.23. ( A, A-wave velocity; AFF, atrial filling fraction; Ai, time velocity integral of A wave; DT, deceleration time; E, E-wave velocity; Ei, time velocity integral of E wave; IVRT, isovolumic relaxation time; MABP, mean arterial blood pressure; MAR, time from termination of mitral flow to the electrocardiographic R wave; Ti, time velocity integral of total wave.) LVEDP measured by catheterization was correlated with LVEDP(1) (r = 0.52, P Aziz, LVEDP = [0.54 MABP × (1 - EF)] - 2.23, appears to be the most accurate, reliable, and easily applied method for estimating LVEDP noninvasively in patients with preserved left ventricular ejection fraction and an LVEDP < 20 mm Hg. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. High blood pressure medications

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007484.htm High blood pressure medicines To use the sharing features on this page, please enable JavaScript. Treating high blood pressure will help prevent problems such as heart disease, ...

  4. Integration of noninvasive prenatal prediction of fetal blood group into clinical prenatal care

    DEFF Research Database (Denmark)

    Clausen, Frederik Banch

    2014-01-01

    Incompatibility of red blood cell blood group antigens between a pregnant woman and her fetus can cause maternal immunization and, consequently, hemolytic disease of the fetus and newborn. Noninvasive prenatal testing of cell-free fetal DNA can be used to assess the risk of hemolytic disease...

  5. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  6. Psoriasis and high blood pressure.

    Science.gov (United States)

    Salihbegovic, Eldina Malkic; Hadzigrahic, Nermina; Suljagic, Edin; Kurtalic, Nermina; Sadic, Sena; Zejcirovic, Alema; Mujacic, Almina

    2015-02-01

    Psoriasis is a chronic skin ailment which can be connected with an increased occurrence of other illnesses, including high blood pressure. A prospective study has been conducted which included 70 patients affected by psoriasis, both genders, older than 18 years. Average age being 47,14 (SD= ±15,41) years, from that there were 36 men or 51,43 and 34 women or 48,57%. Average duration of psoriasis was 15,52 (SD=±12,54) years. Frequency of high blood pressure in those affected by psoriasis was 54,28%. Average age of the patients with psoriasis and high blood pressure was 53,79 year (SD=±14,15) and average duration of psoriasis was 17,19 years (SD=±13,51). Average values of PASI score were 16,65. Increase in values of PASI score and high blood pressure were statistically highly related (r=0,36, p=0,0001). Psoriasis was related to high blood pressure and there was a correlation between the severity of psoriasis and high blood pressure.

  7. Preventing High Blood Pressure

    Science.gov (United States)

    ... Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN Preventing High Blood Pressure: Healthy Living Habits Recommend on Facebook Tweet Share ... meal and snack options can help you avoid high blood pressure and its complications. Be sure to eat plenty ...

  8. Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure.

    Science.gov (United States)

    Climie, Rachel E D; Schultz, Martin G; Nikolic, Sonja B; Ahuja, Kiran D K; Fell, James W; Sharman, James E

    2012-04-01

    Noninvasive central blood pressure (BP) independently predicts mortality, but current methods are operator-dependent, requiring skill to obtain quality recordings. The aims of this study were first, to determine the validity of an automatic, upper arm oscillometric cuff method for estimating central BP (O(CBP)) by comparison with the noninvasive reference standard of radial tonometry (T(CBP)). Second, we determined the intratest and intertest reliability of O(CBP). To assess validity, central BP was estimated by O(CBP) (Pulsecor R6.5B monitor) and compared with T(CBP) (SphygmoCor) in 47 participants free from cardiovascular disease (aged 57 ± 9 years) in supine, seated, and standing positions. Brachial mean arterial pressure (MAP) and diastolic BP (DBP) from the O(CBP) device were used to calibrate in both devices. Duplicate measures were recorded in each position on the same day to assess intratest reliability, and participants returned within 10 ± 7 days for repeat measurements to assess intertest reliability. There was a strong intraclass correlation (ICC = 0.987, P difference (1.2 ± 2.2 mm Hg) for central systolic BP (SBP) determined by O(CBP) compared with T(CBP). Ninety-six percent of all comparisons (n = 495 acceptable recordings) were within 5 mm Hg. With respect to reliability, there were strong correlations but higher limits of agreement for the intratest (ICC = 0.975, P difference 0.6 ± 4.5 mm Hg) and intertest (ICC = 0.895, P difference 4.3 ± 8.0 mm Hg) comparisons. Estimation of central SBP using cuff oscillometry is comparable to radial tonometry and has good reproducibility. As a noninvasive, relatively operator-independent method, O(CBP) may be as useful as T(CBP) for estimating central BP in clinical practice.

  9. Diet, blood pressure, and multicollinearity.

    Science.gov (United States)

    Reed, D; McGee, D; Yano, K; Hankin, J

    1985-01-01

    Recent reports of an inverse association between dietary calcium intake and hypertension stimulated this analysis of the relationship of blood pressure to more than 20 dietary factors among a group of 8000 Japanese men in Hawaii. Reported intakes of potassium, calcium, protein, and milk were all inversely associated with blood pressure levels when examined one at a time while controlling for other risk factors. Alcohol intake was directly associated with blood pressure, and was treated as a confounding variable in the analysis. The association of potassium intake with blood pressure was relatively stronger than the associations for other nutrients, but the intake of potassium was so highly correlated with intakes of calcium, milk, and protein that it was not statistically possible to identify the independent association of potassium and blood pressure. Calcium intake was strongly correlated with milk and potassium intakes, and only calcium from dairy sources was associated with blood pressure. These data thus indicate that several dietary factors are inversely related to blood pressure levels independently of other risk factors such as age, body mass, and alcohol intake. The high degree of intercorrelation (multicollinearity) among these dietary factors, however, indicates that the independent role of any specific nutrient cannot be conclusively separated from the possible effects of other nutrients in this type of study.

  10. Alcohol: Does It Affect Blood Pressure?

    Science.gov (United States)

    Alcohol: Does it affect blood pressure? Does drinking alcohol affect your blood pressure? Answers from Sheldon G. Sheps, M.D. Drinking too much alcohol can raise blood pressure to unhealthy levels. Having ...

  11. Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization

    International Nuclear Information System (INIS)

    Wróbel, M.S.

    2016-01-01

    The number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its perforation. This paper presents the limitations and possibilities of non-invasive blood glucose monitoring with Raman spectroscopy. Especially focusing on the possibilities for device miniaturization. Such device incorporates a Raman spectrometer, a fiber-optical probe, and a computing device (microcontroller, smartphone, etc.) which calculates the glucose concentration using specialized algorithms. Simplification of device design, as well as turbidity correction technique and a new proposed method of synchronized detection are described

  12. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... other risk factors, like diabetes, you may need treatment. How does high blood pressure affect pregnant women? A few women will get ... HIV, Birth Control Heart Health for Women Pregnancy Menopause More Women's Health ... High Blood Pressure--Medicines to Help You Women and Diabetes Heart ...

  13. Noninvasive measurement of blood flow and extraction fraction

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-10-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen.

  14. Noninvasive measurement of blood flow and extraction fraction

    International Nuclear Information System (INIS)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-01-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen. (author)

  15. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure

    DEFF Research Database (Denmark)

    Overvad, Kim

    2018-01-01

    interventions to control blood pressure in the hypertensive population). Our aim was to quantify the contributions of these two phenomena to the worldwide trends in the prevalence of raised blood pressure. Methods: We pooled 1018 population-based studies with blood pressure measurements on 88.6 million......, where relevant. We used a linear mixed effect model to quantify the association between (probit-transformed) prevalence of raised blood pressure and age-group- and sex-specific mean blood pressure. We calculated the contributions of change in mean SBP and DBP, and of change in the prevalence...... participants from 1985 to 2016. We first calculated mean systolic blood pressure (SBP), mean diastolic blood pressure (DBP) and prevalence of raised blood pressure by sex and 10-year age group from 20-29 years to 70-79 years in each study, taking into account complex survey design and survey sample weights...

  16. African Americans and High Blood Pressure

    Science.gov (United States)

    ANSWERS by heart Lifestyle + Risk Reduction High Blood Pressure What About African Americans and High Blood Pressure? African Americans in the U.S. have a higher prevalence of high blood pressure (HBP) than ...

  17. Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.

    Science.gov (United States)

    Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D

    2017-06-27

    Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  18. Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT.

    Science.gov (United States)

    Komar, Gaber; Oikonen, Vesa; Sipilä, Hannu; Seppänen, Marko; Minn, Heikki

    2012-11-01

    The aim of this study was to develop a simple noninvasive method for measuring blood flow using [15O]H2O PET/CT for the head and neck area applicable in daily clinical practice. Fifteen dynamic [15O]H2O PET emission scans with simultaneous online radioactivity measurements of radial arterial blood [Blood-input functions (IFs)] were performed. Two noninvasively obtained population-based input functions were calculated by averaging all Blood-IF curves corrected for patients' body mass and injected dose [standardized uptake value (SUV)-IF] and for body surface area (BSA-IF) and injected dose. Parametric perfusion images were calculated for each set of IFs using a linearized two-compartment model, and values for several tissues were compared using Blood-IF as the gold standard. On comparing all tissues, the correlation between blood flow obtained with the invasive Blood-IF and both SUV-IF and BSA-IF was significant (R2=0.785 with P<0.001 and R2=0.813 with P<0.001, respectively). In individual tissues, the performance of the two noninvasive methods was most reliable in resting muscle and slightly less reliable in tumour and cerebellar regions. In these two tissues, only BSA-IF showed a significant correlation with Blood-IF (R2=0.307 with P=0.032 in tumours and R2=0.398 with P<0.007 in the cerebellum). The BSA-based noninvasive method enables clinically relevant delineation between areas of low and high blood flow in tumours. The blood flow of low-perfusion tissues can be reliably quantified using either of the evaluated noninvasive methods.

  19. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Directory of Open Access Journals (Sweden)

    Senn Oliver

    2010-04-01

    Full Text Available Abstract Background Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Objective Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Outcome Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary. Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries. Methods/Design Randomised controlled study. Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system. Expected results/conclusion The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range ≤ 140/≤ 90 mmHg, yellow: blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg lead to better self-monitoring compared with the conventional (non-colour-coded blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. Trial registration ClinicalTrials.gov ID NCT01013467

  20. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    Science.gov (United States)

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  1. Blood pressure in childhood : epidemiological probes into the aetiology of high blood pressure

    NARCIS (Netherlands)

    A. Hofman (Albert)

    1983-01-01

    textabstractHigh arterial blood pressure takes a heavy toll in western populations (1 ). Its causes are still largely unknown, but its sequelae, a variety of cardiovascular and renal diseases, have been referred to as "a modern scourge" (2). High blood pressure of unknown cause, or

  2. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  3. Non-invasive Blood Glucose Quantification Using a Hybrid Sensor

    Directory of Open Access Journals (Sweden)

    Sundararajan JAYAPAL

    2009-02-01

    Full Text Available Diabetes Mellitus is a group of metabolic diseases characterized by high blood sugar (glucose levels which result from defects in insulin secretion. It is very important for the diabetics and normal people to have a correct blood glucose level. The HbA1c test is the most preferred test by renowned doctors for glucose quantification. But this test is an invasive one. At present, there are many available techniques for this purpose but these are mostly invasive or minimally non-invasive and most of these are under research. Among the different methods available, the photo acoustic (PA methods provide a reliable solution since the acoustical energy loss is much less compared to the optical or other techniques. Here a novel framework is presented for blood glucose level measurement using a combination of the HbA1c test and a PA method to get an absolutely consistent and precise, non-invasive technique. The setup uses a pulsed laser diode with pulse duration of 5-15 ns and at a repetition rate of 10 Hz as the source. The detector setup is based on the piezoelectric detection. It consists of a ring detector that includes two double ring sensors that are attached to the ring shaped module that can be worn around the finger. The major aim is to detect the photo acoustic signals from the glycated hemoglobin with the least possible error. The proposed monitoring system is designed with extreme consideration to precision and compatibility with the other computing devices. The results obtained in this research have been studied and analyzed by comparing these with those of in-vitro techniques like the HPLC. The comparison has been plotted and it shows a least error. The results also show a positive drive for using this concept as a basis for future extension in quantifying the other blood components.

  4. Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy.

    Science.gov (United States)

    Pandey, Rishikesh; Paidi, Santosh Kumar; Valdez, Tulio A; Zhang, Chi; Spegazzini, Nicolas; Dasari, Ramachandra Rao; Barman, Ishan

    2017-02-21

    The successful development of a noninvasive blood glucose sensor that can operate reliably over sustained periods of time has been a much sought after but elusive goal in diabetes management. Since diabetes has no well-established cure, control of elevated glucose levels is critical for avoiding severe secondary health complications in multiple organs including the retina, kidney and vasculature. While fingerstick testing continues to be the mainstay of blood glucose detection, advances in electrochemical sensing-based minimally invasive approaches have opened the door for alternate methods that would considerably improve the quality of life for people with diabetes. In the quest for better sensing approaches, optical technologies have surfaced as attractive candidates as researchers have sought to exploit the endogenous contrast of glucose, notably its absorption, scattering, and polarization properties. Vibrational spectroscopy, especially spontaneous Raman scattering, has exhibited substantial promise due to its exquisite molecular specificity and minimal interference of water in the spectral profiles acquired from the blood-tissue matrix. Yet, it has hitherto been challenging to leverage the Raman scattering signatures of glucose for prediction in all but the most basic studies and under the least demanding conditions. In this Account, we discuss the newly developed array of methodologies that address the key challenges in measuring blood glucose accurately using Raman spectroscopy and unlock new prospects for translation to sustained noninvasive measurements in people with diabetes. Owing to the weak intensity of spontaneous Raman scattering, recent research has focused on enhancement of signals from the blood constituents by designing novel excitation-collection geometries and tissue modulation methods while our attempts have led to the incorporation of nonimaging optical elements. Additionally, invoking mass transfer modeling into chemometric algorithms has

  5. Child Abuse, Resting Blood Pressure, and Blood Pressure Reactivity to Psychosocial Stress.

    Science.gov (United States)

    Gooding, Holly C; Milliren, Carly E; Austin, S Bryn; Sheridan, Margaret A; McLaughlin, Katie A

    2016-01-01

    Childhood trauma is associated with hypertension in adults. It is unknown whether childhood trauma predicts elevated blood pressure earlier in development. We investigated whether the trauma of child abuse was associated with blood pressure in adolescents. The sample included 145 adolescents aged 13-17 years, 40% with exposure to child abuse. The mean age of participants was 14.93 years (SD = 1.33); 58% were female. The majority self-identified as non-Hispanic White (43%), with the remainder identifying as non-Hispanic Black (17%), Hispanic (17%), or other/mixed race (23%). We used established age/sex/height-specific cutoffs to determine the prevalence of prehypertension and hypertension in the sample. We used two-sample t tests to examine associations of abuse with resting systolic blood pressure (SBP) and diastolic blood pressure (DBP) and blood pressure reactivity to the Trier Social Stress Test and a frustration task. We used linear regression to adjust for potential confounders including sociodemographic variables, body mass index, smoking, and psychopathology. Mean resting SBP and DBP were 114.07 mmHg and 61.35 mmHg in those with a history of abuse and 111.39 mmHg and 56.89 mmHg in those without a history of abuse. This difference was significant for DBP only. Twelve percent of participants met criteria for prehypertension or hypertension based on resting blood pressure values; this did not differ between those with and without an abuse history. Child abuse was associated with lower DBP and SBP reactivity to laboratory stress tasks and reduced DBP reactivity to frustration. These associations were robust to adjustment for potential confounders. Child abuse is associated with higher resting DBP and blunted DBP and SBP reactivity to laboratory stress in adolescence. These findings suggest a potential pathway by which child abuse leads to hypertension. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All

  6. 21 CFR 870.1100 - Blood pressure alarm.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  7. Association between ambient temperature and blood pressure and blood pressure regulators: 1831 hypertensive patients followed up for three years.

    Directory of Open Access Journals (Sweden)

    Qing Chen

    Full Text Available Several studies have suggested an association between ambient air temperature and blood pressure. However, this has not been reliably confirmed by longitudinal studies. Also, whether the reaction to temperature stimulation is modified by other factors such as antihypertensive medication is rarely investigated. The present study explores the relationship between ambient temperature and blood pressure, without and with antihypertensive medication, in a study of 1,831 hypertensive patients followed up for three years, in two or four weekly check ups, accumulating 62,452 follow-up records. Both baseline and follow-up blood pressure showed an inverse association with ambient temperature, which explained 32.4% and 65.6% of variation of systolic blood pressure and diastolic blood pressure (P<0.05 respectively. The amplitude of individual blood pressure fluctuation with temperature throughout a year (a 29 degrees centigrade range was 9.4/7.3 mmHg. Medication with angiotensin converting enzyme inhibitor benazepril attenuated the blood pressure fluctuation by 2.4/1.3 mmHg each year, though the inverse association of temperature and blood pressure remained. Gender, drinking behavior and body mass index were also found to modify the association between temperature and diastolic blood pressure. The results indicate that ambient temperature may negatively regulate blood pressure. Hypertensive patients should monitor and treat blood pressure more carefully in cold days, and it could be especially important for the males, thinner people and drinkers.

  8. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  9. High Blood Pressure in Pregnancy

    Science.gov (United States)

    ... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...

  10. High blood pressure - medicine-related

    Science.gov (United States)

    Drug-induced hypertension is high blood pressure caused by using a chemical substance or medicine. ... of the arteries There are several types of high blood pressure : Essential hypertension has no cause that can be ...

  11. Successful management of drug-induced hypercapnic acidosis with naloxone and noninvasive positive pressure ventilation.

    Science.gov (United States)

    Agrafiotis, Michalis; Tryfon, Stavros; Siopi, Demetra; Chassapidou, Georgia; Galanou, Artemis; Tsara, Venetia

    2015-02-01

    A 74-year-old man was referred to our hospital due to deteriorating level of consciousness and desaturation. His Glasgow Coma Scale was 6, and his pupils were constricted but responded to light. Chest radiograph was negative for significant findings. Arterial blood gas evaluation on supplemental oxygen revealed severe acute on chronic respiratory acidosis: pH 7.15; PCO2, 133 mm Hg; PO2,64 mm Hg; and HCO3, 31 mmol/L. He regained full consciousness (Glasgow Coma Scale, 15) after receiving a 0.4 mg dose of naloxone, but because of persistent severe respiratory acidosis (pH 7.21; PCO2, 105 mm Hg), he was immediately commenced on noninvasive positive pressure ventilation (NIV) displaying a remarkable improvement in arterial blood gas values within the next few hours. However, in the days that followed, he remained dependent on NIV, and he was finally discharged on a home mechanical ventilation prescription. In cases of drug-induced respiratory depression, NIV should be regarded as an acceptable treatment, as it can provide ventilatory support without the increased risks associated with invasive mechanical ventilation.

  12. Ambulatory blood pressure profiles in familial dysautonomia.

    Science.gov (United States)

    Goldberg, Lior; Bar-Aluma, Bat-El; Krauthammer, Alex; Efrati, Ori; Sharabi, Yehonatan

    2018-02-12

    Familial dysautonomia (FD) is a rare genetic disease that involves extreme blood pressure fluctuations secondary to afferent baroreflex failure. The diurnal blood pressure profile, including the average, variability, and day-night difference, may have implications for long-term end organ damage. The purpose of this study was to describe the circadian pattern of blood pressure in the FD population and relationships with renal and pulmonary function, use of medications, and overall disability. We analyzed 24-h ambulatory blood pressure monitoring recordings in 22 patients with FD. Information about medications, disease severity, renal function (estimated glomerular filtration, eGFR), pulmonary function (forced expiratory volume in 1 s, FEV1) and an index of blood pressure variability (standard deviation of systolic pressure) were analyzed. The mean (± SEM) 24-h blood pressure was 115 ± 5.6/72 ± 2.0 mmHg. The diurnal blood pressure variability was high (daytime systolic pressure standard deviation 22.4 ± 1.5 mmHg, nighttime 17.2 ± 1.6), with a high frequency of a non-dipping pattern (16 patients, 73%). eGFR, use of medications, FEV1, and disability scores were unrelated to the degree of blood pressure variability or to dipping status. This FD cohort had normal average 24-h blood pressure, fluctuating blood pressure, and a high frequency of non-dippers. Although there was evidence of renal dysfunction based on eGFR and proteinuria, the ABPM profile was unrelated to the measures of end organ dysfunction or to reported disability.

  13. The hidden magnitude of raised blood pressure and elevated blood ...

    African Journals Online (AJOL)

    Conclusions: The prevalence of undiagnosed raised blood pressure and elevated blood sugar was high in Ethiopia and only very small percentage of people had been aware of their high blood pressure and elevated blood sugar. Policy makers in the health sector including other health development partners need to ...

  14. Pressure Ulcer Incidence in Patients Wearing Nasal-Oral Versus Full-Face Noninvasive Ventilation Masks.

    Science.gov (United States)

    Schallom, Marilyn; Cracchiolo, Lisa; Falker, Antoinette; Foster, Jennifer; Hager, JoAnn; Morehouse, Tamara; Watts, Peggy; Weems, Linda; Kollef, Marin

    2015-07-01

    Device-related pressure ulcers from noninvasive ventilation masks alter skin integrity and cause patients discomfort. To examine the incidence, location, and stage of pressure ulcers and patients' comfort with a nasal-oral mask compared with a full-face mask. A before-after study of a convenience sample of patients with noninvasive ventilation orders in 5 intensive care units was conducted. Two groups of 100 patients each received either the nasal-oral mask or the full-face mask. Skin was assessed before the mask was applied and every 12 hours after that or upon mask removal. Comfort levels were assessed every 12 hours on a Likert scale of 1 to 5 (1, most comfortable). A pressure ulcer developed in 20% of patients in the nasal-oral mask group and 2% of patients in the full-face mask group (P face mask (mean [SD], 1.9 [1.1]) than with the nasal-oral mask (mean [SD], 2.7 [1.2], P face mask and 25 (SD, 20.7) and 92% for nasal-oral mask. No patients who had a pressure ulcer develop with the nasal-oral mask had a pressure ulcer develop with the full-face mask. The full-face mask resulted in significantly fewer pressure ulcers and was more comfortable for patients. The full-face mask is a reasonable alternative to traditional nasal-oral masks for patients receiving noninvasive ventilation. ©2015 American Association of Critical-Care Nurses.

  15. Blood pressure monitors for home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... may ask you to keep track of your blood pressure at home. To do this, you will need ...

  16. Blood pressure documentation in the emergency department

    Science.gov (United States)

    Daniel, Ana Carolina Queiroz Godoy; Machado, Juliana Pereira; Veiga, Eugenia Velludo

    2017-01-01

    ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department. PMID:28444085

  17. The use of diameter distension waveforms as an alternative for tonometric pressure to assess carotid blood pressure

    International Nuclear Information System (INIS)

    Kips, Jan; Mahieu, Dries; Fabry, Isabelle; Van Bortel, Luc; Vanmolkot, Floris; De Hoon, Jan; Vermeersch, Sebastian; Segers, Patrick

    2010-01-01

    Proper non-invasive assessment of carotid artery pressure ideally uses waveforms recorded at two anatomical locations: the brachial and the carotid artery. Calibrated diameter distension waveforms could provide a more widely applicable alternative for local arterial pressure assessment than applanation tonometry. This approach might be of particular use at the brachial artery, where the feasibility of a reliable tonometric measurement has been questioned. The aim of this study was to evaluate an approach based on distension waveforms obtained at the brachial and carotid arteries. This approach will be compared to traditional pulse pressures obtained through tonometry at both the carotid and brachial arteries (used as a reference) and the more recently proposed approach of combining tonometric readings at the brachial artery with linearly or exponentially calibrated distension curves at the carotid artery. Local brachial and carotid diameter distension and tonometry waveforms were recorded in 148 subjects (119 women; aged 19–59 years). The morphology of the waveforms was compared by the form factor and the root-mean-squared error. The difference between the reference carotid PP and the PP obtained from brachial and carotid distension waveforms was smaller (0.9 (4.9) mmHg or 2.3%) than the difference between the reference carotid PP and the estimates obtained using a tonometric and a distension waveform (−4.8 (2.5) mmHg for the approach using brachial tonometry and linearly scaled carotid distension, and 2.7 (6.8) mmHg when using exponentially scaled carotid distension waves). We therefore recommend to stick to one technique on both the brachial and the carotid artery, either tonometry or distension, when assessing carotid blood pressure non-invasively

  18. Common High Blood Pressure Myths

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Common High Blood Pressure Myths Updated:May 4,2018 Knowing the facts ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  19. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  20. Medications for High Blood Pressure

    Science.gov (United States)

    ... Consumers Home For Consumers Consumer Updates Medications for High Blood Pressure Share Tweet Linkedin Pin it More sharing options ... age and you cannot tell if you have high blood pressure by the way you feel, so have your ...

  1. High blood pressure and diet

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007483.htm High blood pressure and diet To use the sharing features on ... diet is a proven way to help control high blood pressure . These changes can also help you lose weight ...

  2. Sodium-blood pressure interrelationship in pregnancy.

    Science.gov (United States)

    Franx, A; Steegers, E A; de Boo, T; Thien, T; Merkus, J M

    1999-03-01

    In non-pregnant individuals, a strong positive association of sodium intake with blood pressure has been established, but the relationship between sodium intake and blood pressure in human pregnancy remains obscure up to date. The aim of this prospective observational cohort study was to assess the relationship between urinary sodium excretion (as a measure for intake) and blood pressure from the early second trimester onwards throughout pregnancy. The study group consisted of 667 low-risk women with singleton pregnancies, of whom 350 were nulliparous and 317 parous. Blood pressure was measured in a standardised fashion at predetermined intervals from the first antenatal visit prior to 16 weeks gestation until delivery. Urinary sodium excretion was measured in 24-h urine collections on at least four occasions between 16 and 38 weeks gestation. Main outcome measures were the coefficients of correlation between changes in urinary sodium output and changes in blood pressure during six different gestational epochs. No significant correlations were found between changes in urinary sodium output and changes in blood pressure. Correlation coefficients were alike for nulliparous and parous women and for different gestational intervals. Prior to 32 weeks gestation, no differences were observed in sodium excretion between women who remained normotensive and those who developed gestational hypertension. These results suggest that changes in sodium intake are not associated with blood pressure changes in low-risk pregnant women. Blood pressure increases as observed in the second half of normotensive and hypertensive pregnancies are unlikely to be caused by changes in renal sodium handling.

  3. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  4. Blood Pressure Drugs and AMD

    Science.gov (United States)

    ... Patient Stories Español Eye Health / News Research News: Blood Pressure Drugs and AMD Leer en Español: Noticias de ... also found an association between AMD and high blood pressure, but this has been inconsistent. To help clarify ...

  5. What Is High Blood Pressure?

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  6. High blood pressure and eye disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000999.htm High blood pressure and eye disease To use the sharing features on this page, please enable JavaScript. High blood pressure can damage blood vessels in the retina . The ...

  7. Smart blood pressure holter.

    Science.gov (United States)

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  8. Anxiety: A Cause of High Blood Pressure?

    Science.gov (United States)

    ... of high blood pressure? Can anxiety cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Anxiety doesn't cause long-term high blood pressure (hypertension). But episodes of anxiety can cause dramatic, ...

  9. Diabetes and blood pressure (image)

    Science.gov (United States)

    People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ... People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ...

  10. Low-pressure sequential compression of lower limbs enhances forearm skin blood flow.

    Science.gov (United States)

    Amah, Guy; Voicu, Sebastian; Bonnin, Philippe; Kubis, Nathalie

    2016-12-01

    We investigated whether forearm skin blood flow could be improved when a multilayer pulsatile inflatable suit was applied at a low pressure to the lower limbs and abdomen. We hypothesized that a non-invasive purely mechanical stimulation of the lower limbs could induce remote forearm blood flow modifications. The pulsatile suit induced a sequential compartmentalized low compression (65 mmHg), which was synchronized with each diastole of the cardiac cycle with each phase evolving centripetally (lower limbs to abdomen). Modifications of the forearm skin blood flow were continuously recorded by laser Doppler flowmetry (LDF) at baseline and during the pulsatile suit application. Endothelium-dependent and endothelium-independent vasodilations of the forearm skin microcirculation were measured by LDF in response to a local transdermal iontophoretic application of acetylcholine (ACh-test) and to hyperthermia (hyperT- test). Twenty-four healthy volunteers, 12 men and 12 women (43±14 years) were included in the study. LDF responses increased 1) under pulsatile suit (97±106%, p.

  11. Social Stress Induced Pressure Breathing and Consequent Blood Pressure Oscillation

    NARCIS (Netherlands)

    Fokkema, Dirk S.; Koolhaas, Jaap M.; Meulen, Jan van der; Schoemaker, Regien

    1986-01-01

    A large amplitude blood pressure oscillation occurs during social defeat in a territorial fight between male rats, and during the application of a psychosocial stimulus associated with this defeat. Synchronous recording of blood pressure, intrathoracic pressure and diaphragm activity shows that the

  12. Contributions of social context to blood pressure: findings from a multilevel analysis of social capital and systolic blood pressure.

    Science.gov (United States)

    Hamano, Tsuyoshi; Fujisawa, Yoshikazu; Yamasaki, Masayuki; Ito, Katsuhisa; Nabika, Toru; Shiwaku, Kuninori

    2011-06-01

    In recent years, few studies have quantified the effect of residential context on blood pressure. Although these studies have emphasized the importance of socioeconomic influences such as education or poverty levels, the association between the features of social structure such as social capital and blood pressure remain unclear. Therefore, we investigated whether social capital was associated with systolic blood pressure after controlling for individual potential confounders. We analyzed data from the Shimane Study conducted from 2006 to 2008 in rural mountainous regions of Japan. After excluding the missing data and data of participants taking hypertension medication, we conducted a multilevel analysis of the data for 335 individuals nested within 30 postcode sectors. Systolic blood pressure increased with increasing age and body mass index. We also found that a higher systolic blood pressure was observed among smokers and those taking medication for diabetes. Regarding the contextual effects of social capital, systolic blood pressure increased with an increasing proportion of lack of fairness, after adjustment for individual confounders. To the best of our knowledge, this study is the first to investigate the association between social capital and systolic blood pressure by using a multilevel methodological framework. Surprisingly, we found that lack of fairness had a strong effect on systolic blood pressure. However, we could not find any significant associations between other items of social capital and systolic blood pressure. Further studies are needed to clarify the mechanism by which lack of fairness may have an effect on systolic blood pressure.

  13. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    Science.gov (United States)

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  14. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  15. Noninvasive in vivo optical characterization of blood flow and oxygen consumption in the superficial plexus of skin

    Science.gov (United States)

    Liasi, Faezeh Talebi; Samatham, Ravikant; Jacques, Steven L.

    2017-11-01

    Assessing the metabolic activity of a tissue, whether normal, damaged, aged, or pathologic, is useful for diagnosis and evaluating the effects of drugs. This report describes a handheld optical fiber probe that contacts the skin, applies pressure to blanch the superficial vascular plexus of the skin, then releases the pressure to allow refill of the plexus. The optical probe uses white light spectroscopy to record the time dynamics of blanching and refilling. The magnitude and dynamics of changes in blood content and hemoglobin oxygen saturation yield an estimate of the oxygen consumption rate (OCR) in units of attomoles per cell per second. The average value of OCR on nine forearm sites on five subjects was 10±5 (amol/cell/s). This low-cost, portable, rapid, noninvasive optical probe can characterize the OCR of a skin site to assess the metabolic activity of the epidermis or a superficial lesion.

  16. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  17. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  18. High Blood Pressure: Medicines to Help You

    Science.gov (United States)

    ... For Consumers Consumer Information by Audience For Women High Blood Pressure--Medicines to Help You Share Tweet Linkedin Pin ... Click here for the Color Version (PDF 533KB) High blood pressure is a serious illness. High blood pressure is ...

  19. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    Directory of Open Access Journals (Sweden)

    Korenfeld MS

    2016-01-01

    Full Text Available Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods: A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results: The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. Conclusion: This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure. Keywords: glaucoma, intraocular pressure, tonometer, ocular compression

  20. Hemodynamic mechanisms of the attenuated blood pressure response to mental stress after a single bout of maximal dynamic exercise in healthy subjects

    Directory of Open Access Journals (Sweden)

    F.J. Neves

    2012-07-01

    Full Text Available To determine the hemodynamic mechanisms responsible for the attenuated blood pressure response to mental stress after exercise, 26 healthy sedentary individuals (age 29 ± 8 years underwent the Stroop color-word test before and 60 min after a bout of maximal dynamic exercise on a treadmill. A subgroup (N = 11 underwent a time-control experiment without exercise. Blood pressure was continuously and noninvasively recorded by infrared finger photoplethysmography. Stroke volume was derived from pressure signals, and cardiac output and peripheral vascular resistance were calculated. Perceived mental stress scores were comparable between mental stress tests both in the exercise (P = 0.96 and control (P = 0.24 experiments. After exercise, the blood pressure response to mental stress was attenuated (pre: 10 ± 13 vs post: 6 ± 7 mmHg; P 0.05. In conclusion, a single bout of maximal dynamic exercise attenuates the blood pressure response to mental stress in healthy subjects, along with lower stroke volume and cardiac output, denoting an acute modulatory action of exercise on the central hemodynamic response to mental stress.

  1. Clinical results from a noninvasive blood glucose monitor

    Science.gov (United States)

    Blank, Thomas B.; Ruchti, Timothy L.; Lorenz, Alex D.; Monfre, Stephen L.; Makarewicz, M. R.; Mattu, Mutua; Hazen, Kevin

    2002-05-01

    Non-invasive blood glucose monitoring has long been proposed as a means for advancing the management of diabetes through increased measurement and control. The use of a near-infrared, NIR, spectroscopy based methodology for noninvasive monitoring has been pursued by a number of groups. The accuracy of the NIR measurement technology is limited by challenges related to the instrumentation, the heterogeneity and time-variant nature of skin tissue, and the complexity of the calibration methodology. In this work, we discuss results from a clinical study that targeted the evaluation of individual calibrations for each subject based on a series of controlled calibration visits. While the customization of the calibrations to individuals was intended to reduce model complexity, the extensive requirements for each individual set of calibration data were difficult to achieve and required several days of measurement. Through the careful selection of a small subset of data from all samples collected on the 138 study participants in a previous study, we have developed a methodology for applying a single standard calibration to multiple persons. The standard calibrations have been applied to a plurality of individuals and shown to be persistent over periods greater than 24 weeks.

  2. Estimation of coronary wave intensity analysis using noninvasive techniques and its application to exercise physiology.

    Science.gov (United States)

    Broyd, Christopher J; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Jones, Siana; Al-Lamee, Rasha; Foin, Nicolas; Al-Bustami, Mahmud; Sethi, Amarjit; Kaprielian, Raffi; Ramrakha, Punit; Khan, Masood; Malik, Iqbal S; Francis, Darrel P; Parker, Kim; Hughes, Alun D; Mikhail, Ghada W; Mayet, Jamil; Davies, Justin E

    2016-03-01

    Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. -13.8 ± 7.1 × 10(4) W·m(-2)·s(-2), concordance correlation coefficient (CCC): 0.73, P Exercise increased the BDW: at maximum exercise peak BDW was -47.0 ± 29.5 × 10(4) W·m(-2)·s(-2) (P Physiological Society.

  3. High Blood Pressure - Multiple Languages

    Science.gov (United States)

    ... Being 8 - High Blood Pressure - Amarɨñña / አማርኛ (Amharic) MP3 Siloam Family Health Center Arabic (العربية) Expand Section ... Being 8 - High Blood Pressure - myanma bhasa (Burmese) MP3 Siloam Family Health Center Chinese, Simplified (Mandarin dialect) ( ...

  4. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a silent threat to health. So come and get your blood pressure checked.

  5. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a stealth threat to health. So come and get your blood pressure checked.

  6. Effects of hormone therapy on blood pressure.

    Science.gov (United States)

    Issa, Zeinab; Seely, Ellen W; Rahme, Maya; El-Hajj Fuleihan, Ghada

    2015-04-01

    Although hormone therapy remains the most efficacious option for the management of vasomotor symptoms of menopause, its effects on blood pressure remain unclear. This review scrutinizes evidence of the mechanisms of action of hormone therapy on signaling pathways affecting blood pressure and evidence from clinical studies. Comprehensive Ovid MEDLINE searches were conducted for the terms "hypertension" and either of the following "hormone therapy and menopause" or "selective estrogen receptor modulator" from year 2000 to November 2013. In vitro and physiologic studies did not reveal a clear deleterious effect of hormone therapy on blood pressure. The effect of oral therapy was essentially neutral in large trials conducted in normotensive women with blood pressure as primary outcome. Results from all other trials had several limitations. Oral therapy had a neutral effect on blood pressure in hypertensive women. Transdermal estrogen and micronized progesterone had a beneficial effect on blood pressure in normotensive women and, at most, a neutral effect on hypertensive women. In general, tibolone and raloxifene had a neutral effect on blood pressure in both hypertensive and normotensive women. Large randomized trials are needed to assess the effect of oral hormone therapy on blood pressure as a primary outcome in hypertensive women and the effect of transdermal preparations on both normotensive and hypertensive women. Transdermal preparations would be the preferred mode of therapy for hypertensive women, in view of their favorable physiologic and clinical profiles. The decision regarding the use of hormone therapy should be individualized, and blood pressure should be monitored during the course of treatment.

  7. Blood pressure regulation in diabetic autonomic neuropathy

    DEFF Research Database (Denmark)

    Hilsted, J

    1985-01-01

    Defective blood pressure responses to standing, exercise and epinephrine infusions have been demonstrated in diabetic patients with autonomic neuropathy. The circulatory mechanisms underlying blood pressure responses to exercise and standing up in these patients are well characterized: In both...... which may contribute to exercise hypotension in these patients. During hypoglycemia, blood pressure regulation seems intact in patients with autonomic neuropathy. This is probably due to release of substantial amounts of catecholamines during these experiments. During epinephrine infusions a substantial...... blood pressure fall ensues in patients with autonomic neuropathy, probably due to excessive muscular vasodilation. It is unresolved why blood pressure regulation is intact during hypoglycemia and severely impaired--at similar catecholamine concentrations--during epinephrine infusions....

  8. Understanding Blood Pressure Readings

    Science.gov (United States)

    ... Venous Thromboembolism Aortic Aneurysm More Understanding Blood Pressure Readings Updated:Jun 1,2018 What do your blood ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, ...

  9. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  10. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  11. Title: variations and sensitivities of some blood pressure monitors ...

    African Journals Online (AJOL)

    Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Accuracy in blood pressure meters is of essence to health, especially in blood pressure monitoring and treatment. The aim of this research was to compare the readings and the sensitivities of some blood pressure monitors in use ...

  12. Sleep deprivation increases blood pressure in healthy normotensive elderly and attenuates the blood pressure response to orthostatic challenge.

    Science.gov (United States)

    Robillard, Rébecca; Lanfranchi, Paola A; Prince, François; Filipini, Daniel; Carrier, Julie

    2011-03-01

    To determine how aging affects the impact of sleep deprivation on blood pressure at rest and under orthostatic challenge. Subjects underwent a night of sleep and 24.5 h of sleep deprivation in a crossover counterbalanced design. Sleep laboratory. Sixteen healthy normotensive men and women: 8 young adults (mean 24 years [SD 3.1], range 20-28 years) and 8 elderly adults (mean 64.1 years [SD 3.4], range 60-69 years). Sleep deprivation. Brachial cuff arterial blood pressure and heart rate were measured in semi-recumbent and upright positions. These measurements were compared across homeostatic sleep pressure conditions and age groups. Sleep deprivation induced a significant increase in systolic and diastolic blood pressure in elderly but not young adults. Moreover, sleep deprivation attenuated the systolic blood pressure orthostatic response in both age groups. Our results suggest that sleep deprivation alters the regulatory mechanisms of blood pressure and might increase the risk of hypertension in healthy normotensive elderly.

  13. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  14. High blood pressure - adults

    Science.gov (United States)

    ... pressure is found. This is called essential hypertension. High blood pressure that is caused by another medical condition or medicine you are taking is called secondary hypertension. Secondary hypertension may be due to: Chronic ...

  15. Face Masks for Noninvasive Ventilation: Fit, Excess Skin Hydration, and Pressure Ulcers.

    Science.gov (United States)

    Visscher, Marty O; White, Cynthia C; Jones, Jennifer M; Cahill, Thomas; Jones, Donna C; Pan, Brian S

    2015-11-01

    Pressure ulcers (stages III and IV) are serious safety events (ie, never events). Healthcare institutions are no longer reimbursed for costs to care for affected patients. Medical devices are the leading cause of pediatric pressure ulcers. Face masks for noninvasive ventilation were associated with a high percentage of pressure ulcers at our institution. A prospective cohort study investigated factors contributing to pressure ulcer development in 50 subjects using face masks for noninvasive ventilation. Color imaging, 3-dimensional surface imaging, and skin hydration measurements were used to identify early skin compromise and evaluate 3 interventions to reduce trauma: (1) a silicone foam dressing, (2) a water/polyethylene oxide hydrogel dressing, and (3) a flexible cloth mask. A novel mask fit technique was used to examine the impact of fit on the potential for skin compromise. Fifty subjects age 10.4 ± 9.1 y participated with color images for 22, hydration for 34, and mask fit analysis for 16. Of these, 69% had diagnoses associated with craniofacial anomalies. Stage I pressure ulcers were the most common injury. Skin hydration difference was 317 ± 29 for sites with erythema versus 75 ± 28 for sites without erythema (P skin erythema and pressure ulcers. This fit method is currently being utilized to select best-fit masks from available options, to identify the potential areas of increased tissue pressure, and to prevent skin injuries and their complications. Improvement of mask fit is an important priority for improving respiratory outcomes. Strategies to maintain normal skin hydration are important for protecting tissue integrity. Copyright © 2015 by Daedalus Enterprises.

  16. Diurnal changes of blood pressure values (24 h blood pressures in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Barbara Grzechocińska

    2011-06-01

    Full Text Available Background: More attention is being paid lately to polycystic ovary syndrome (PCOS not only in the aspect of fertility but also according to long-term metabolic and cardiovascular abnormalities. Observations of women with PCOS show that the occurrence of blood hypertension is more frequent after the menopause. There are few articles concerning the predictable symptoms of blood hypertension. It seems that twenty-four hour blood pressure monitoring and assessment of changes of diurnal rhythm could be useful in this group of patients.Aim of the study: The purpose of this study was to assess diurnal changes of blood pressure in women with polycystic ovary syndrome.Material and methods: 26 women with PCOS diagnosed according to Rotterdam consensus criteria and Androgen Excess Society (AES criteria were included in our study. The mean age of the examined women was 29.5 years and the mean BMI (body mass index was 24.7 kg/m2. The control group consisted of 12 age-matched women, without PCOS. Twenty-four hour Holter monitoring of ambulatory blood pressure was performed during normal daily activity in all patients. Halberg’s cosinor method was used to analyse daily biorhythm.Results: Results show the diurnal changes of systolic blood pressure in the preclinical phase in 30% and diastolic in 15% of PCOS women. In this group no physiological decrease of blood pressure at night time was observed.

  17. Non-Invasive Mechanic Ventilation Using in Flail Chest, Caused By Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Serdar Onat

    2008-01-01

    Full Text Available A 75-year-old woman admitted our faculty emergency room with shortness of breath, and chest pain after traffic accident’s second hour. She was diagnosed as bilateral multipl rib fractures, left clavicula fracture, and left flail chest by phsical and radiological examinations. She was transfered to Chest Surgery Depatment’s intensive care unit. The patient was undergone non-invasive mask mechanic ventilation support, because of the decreasing of blood oxygen saturation and increasing of arteriel blood partial carbondioxide pressure. The treatment of non-invasive mechanic ventilation was succesfull for ventilation support. With this report, we would like to attentioned that non-invasive mechanic ventilation for blunt chest trauma patients could be used succesfully and could be used instead of endotracheal invasive mechanic ventilation.

  18. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  19. 21 CFR 870.1120 - Blood pressure cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  20. Noninvasive ventilation.

    Science.gov (United States)

    Rabatin, J T; Gay, P C

    1999-08-01

    Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.

  1. Effect of cocoa on blood pressure.

    Science.gov (United States)

    Ried, Karin; Fakler, Peter; Stocks, Nigel P

    2017-04-25

    High blood pressure is an important risk factor for cardiovascular disease, contributing to about 50% of cardiovascular events worldwide and 37% of cardiovascular-related deaths in Western populations. Epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. Flavanols found in cocoa have been shown to increase the formation of endothelial nitric oxide which promotes vasodilation and therefore blood pressure reduction. Here we update previous meta-analyses on the effect of cocoa on blood pressure. To assess the effects on blood pressure of chocolate or cocoa products versus low-flavanol products or placebo in adults with or without hypertension when consumed for two weeks or longer. This is an updated version of the review initially published in 2012. In this updated version, we searched the following electronic databases from inception to November 2016: Cochrane Hypertension Group Specialised Register, CENTRAL, MEDLINE and Embase. We also searched international trial registries, and the reference lists of review articles and included trials. Randomised controlled trials (RCTs) investigating the effects of chocolate or cocoa products on systolic and diastolic blood pressure in adults for a minimum of two weeks duration. Two review authors independently extracted data and assessed the risks of bias in each trial. We conducted random-effects meta-analyses on the included studies using Review Manager 5. We explored heterogeneity with subgroup analyses by baseline blood pressure, flavanol content of control group, blinding, age and duration. Sensitivity analyses explored the influence of unusual study design. Thirty-five trials (including 40 treatment comparisons) met the inclusion criteria. Of these, we added 17 trials (20 treatment comparisons) to the 18 trials (20 treatment comparisons) in the previous version of this updated review.Trials provided participants with 30 to 1218 mg of flavanols (mean = 670 mg) in 1.4 to 105

  2. Cocoa, blood pressure, and cardiovascular health.

    Science.gov (United States)

    Ferri, Claudio; Desideri, Giovambattista; Ferri, Livia; Proietti, Ilenia; Di Agostino, Stefania; Martella, Letizia; Mai, Francesca; Di Giosia, Paolo; Grassi, Davide

    2015-11-18

    High blood pressure is an important risk factor for cardiovascular disease and cardiovascular events worldwide. Clinical and epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. According to this, cocoa has a high content in polyphenols, especially flavanols. Flavanols have been described to exert favorable effects on endothelium-derived vasodilation via the stimulation of nitric oxide-synthase, the increased availability of l-arginine, and the decreased degradation of NO. Cocoa may also have a beneficial effect by protecting against oxidative stress alterations and via decreased platelet aggregation, decreased lipid oxidation, and insulin resistance. These effects are associated with a decrease of blood pressure and a favorable trend toward a reduction in cardiovascular events and strokes. Previous meta-analyses have shown that cocoa-rich foods may reduce blood pressure. Long-term trials investigating the effect of cocoa products are needed to determine whether or not blood pressure is reduced on a chronic basis by daily ingestion of cocoa. Furthermore, long-term trials investigating the effect of cocoa on clinical outcomes are also needed to assess whether cocoa has an effect on cardiovascular events. A 3 mmHg systolic blood pressure reduction has been estimated to decrease the risk of cardiovascular and all-cause mortality. This paper summarizes new findings concerning cocoa effects on blood pressure and cardiovascular health, focusing on putative mechanisms of action and "nutraceutical " viewpoints.

  3. Fall in blood pressure during radiation therapy

    International Nuclear Information System (INIS)

    Larsson, L.E.; Lindahl, J.; Unsgaard, B.

    1976-01-01

    Blood pressure and heart rate at rest in the supine and standing positions were followed before, during and after irradiation for malignant tumours in 114 patients. A statistically significant gradual reduction in blood pressure during the treatment period was established. This was more marked in older patients and in patients with higher initial blood pressure but was not related to the region irradiated or the type of tumour treated. Particularly if the patient experiences vertigo and nausea on change of position, it seems advisable to check the blood pressure during treatment. (author)

  4. Worldwide trends in blood pressure from 1975 to 2015

    DEFF Research Database (Denmark)

    Linneberg, Allan René; Sørensen, Thorkild I.A.

    2017-01-01

    BACKGROUND: Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood...... pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. METHODS: For this analysis, we pooled national, subnational, or community population-based studies that had measured blood pressure in adults aged 18 years and older. We used a Bayesian hierarchical model to estimate trends...... from 1975 to 2015 in mean systolic and mean diastolic blood pressure, and the prevalence of raised blood pressure for 200 countries. We calculated the contributions of changes in prevalence versus population growth and ageing to the increase in the number of adults with raised blood pressure. FINDINGS...

  5. Inconsistency between simultaneous blood pressure measurements in the arm, forearm, and leg in anesthetized children.

    Science.gov (United States)

    Keidan, Ilan; Sidi, Avner; Ben-Menachem, Erez; Tene, Yael; Berkenstadt, Haim

    2014-02-01

    To determine the accuracy and precision of simultaneous noninvasive blood pressure (NIBP) measurement in the arm, forearm, and ankle in anesthetized children. Prospective, randomized study. University medical center. 101 ASA physical status 1 and 2 children (aged 1-8 yrs) scheduled for elective surgery with general anesthesia. Simultaneous NIBP measurements were recorded at the arm, forearm, and ankle at 5-minute intervals. The systolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 63% and 29% of measurements, and within the ± 20% range in 85% and 67% of measurements, respectively. The diastolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 42% and 44% and within the ± 20% range in 67% and 74% of measurements, respectively. In patients in whom the initial three NIBP measurements were within the ± 20% range between the forearm and arm, 86% of the subsequent measurements were also within that limit. Forearm and ankle NIBP measurements are unreliable and inconsistent with NIBP measured in the arm of anesthetized children. These alternative BP measurement sites are not reliable in accuracy (comparison with reference "gold" standard) and precision (reproducibility). Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Observation of the pulse oximeter trace to estimate systolic blood ...

    African Journals Online (AJOL)

    Background: The estimation of systolic blood pressure by disappearance and reappearance of the pulse oximeter trace during cuff inflation and deflation was compared with non-invasive blood pressure (NIBP) measurement, across the range of body mass index (BMI), during spinal anaesthesia for Caesarean section.

  7. What Is High Blood Pressure Medicine?

    Science.gov (United States)

    ... a medicine calendar. • Set a reminder on your smartphone. What types of medicine may be prescribed? One ... High Blood Pressure Medicine? What are their side effects? For many people, high blood pressure medicine can ...

  8. Letter to editor: Blood pressure, hypertension and lead exposure.

    Science.gov (United States)

    Yang, Wen-Yi; Staessen, Jan A

    2018-02-19

    A significant association of office diastolic blood pressure with low-level blood lead exposure was reported in a Brazilian adult population. However, caution should be taken to interpret these results. The multivariable-adjusted association with blood pressure was positive for diastolic blood pressure, but inverse for systolic blood pressure. The association sizes were infinitesimal without clinical relevance. The outcome measures, i.e. blood pressure and the prevalence of hypertension were analysed across categories of the blood lead distribution - not in relation to blood lead as continuous variable. Blood pressure was the average of two oscillometric office readings, whereas ambulatory monitoring is the state-of-the-art.

  9. Blood Pressure Quiz | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... this page please turn Javascript on. Feature: High Blood Pressure Blood Pressure Quiz Past Issues / Fall 2011 Table of Contents Blood pressure changes throughout the day. It… is highest while ...

  10. Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?

    Science.gov (United States)

    Nobre, Fernando; Mion, Décio

    2005-10-01

    Ambulatory blood pressure monitoring (ABPM) provides relevant data about blood pressure over a 24-h period. The analysis of parameters to determine the blood pressure profile from these data is of great importance. To calculate areas under systolic and diastolic blood pressure curves (SBP-AUC/DBP-AUC) and compare with systolic and diastolic blood pressure load (SBPL/DBPL) and 24-h systolic and diastolic blood pressure (24-h SBP/24-h DBP) in order to determine which provides the best correlation with left ventricular mass index (LVMI). ABPM measurements (1143 individuals) were analyzed to obtain 24-h SBP/24-h DBP, SBPL/DBPL, and SBP-AUC/ DBP-AUC, using Spacelabs (90207) and CardioSistemas devices. Left ventricular mass was determined using an echocardiograph HP Sonos 5500 and LVMI was calculated. The correlations between all possible pairs within the group 24-h SBP/SBPL/SBP-AUC and 24-h DBP/DBPL/DBP-AUC were high and statistically significant. The correlations between 24-h SBP/24-h DBP and SBP-AUC/DBP-AUC with SBPL/DBPL close to 100%, were lower than those mentioned above. The correlations of the parameters obtained by ABPM with LVMI were also high and statistically significant, except for blood pressure load between 90 and 100%, and for 24-h SBP of 135 mmHg or less and SBPL higher than 50%. SBPL/DBPL and SBP-AUC/DBP-AUC can be used for the evaluation of ABPM data owing to the strong correlation with 24-h SBP/24-h DBP and with LVMI, except when SBPL is close to 100% or 24-h SBP is below 135 mmHg but SBPL is above 50%. SBP-AUC/DBP-AUC, however, are a better alternative because they do not have the limitations of blood pressure load or even of 24-h blood pressure present.

  11. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  12. DASH diet to lower high blood pressure

    Science.gov (United States)

    ... patientinstructions/000770.htm DASH diet to lower high blood pressure To use the sharing features on this page, ... Hypertension. The DASH diet can help lower high blood pressure and cholesterol and other fats in your blood. ...

  13. An affordable cuff-less blood pressure estimation solution.

    Science.gov (United States)

    Jain, Monika; Kumar, Niranjan; Deb, Sujay

    2016-08-01

    This paper presents a cuff-less hypertension pre-screening device that non-invasively monitors the Blood Pressure (BP) and Heart Rate (HR) continuously. The proposed device simultaneously records two clinically significant and highly correlated biomedical signals, viz., Electrocardiogram (ECG) and Photoplethysmogram (PPG). The device provides a common data acquisition platform that can interface with PC/laptop, Smart phone/tablet and Raspberry-pi etc. The hardware stores and processes the recorded ECG and PPG in order to extract the real-time BP and HR using kernel regression approach. The BP and HR estimation error is measured in terms of normalized mean square error, Error Standard Deviation (ESD) and Mean Absolute Error (MAE), with respect to a clinically proven digital BP monitor (OMRON HBP1300). The computed error falls under the maximum standard allowable error mentioned by Association for the Advancement of Medical Instrumentation; MAE cost home and clinic bases solution for continuous health monitoring.

  14. An Image Registration Based Technique for Noninvasive Vascular Elastography

    OpenAIRE

    Valizadeh, Sina; Makkiabadi, Bahador; Mirbagheri, Alireza; Soozande, Mehdi; Manwar, Rayyan; Mozaffarzadeh, Moein; Nasiriavanaki, Mohammadreza

    2018-01-01

    Non-invasive vascular elastography is an emerging technique in vascular tissue imaging. During the past decades, several techniques have been suggested to estimate the tissue elasticity by measuring the displacement of the Carotid vessel wall. Cross correlation-based methods are the most prevalent approaches to measure the strain exerted in the wall vessel by the blood pressure. In the case of a low pressure, the displacement is too small to be apparent in ultrasound imaging, especially in th...

  15. Early predictors of success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

    Science.gov (United States)

    Bhattacharyya, D; Prasad, Bnbm; Tampi, P S; Ramprasad, R

    2011-10-01

    Non-invasive positive pressure ventilation (NIPPV) has emerged as a significant advancement in the management of acute hypercapnic respiratory failure. Patients with hypercapnic respiratory failure requiring ventilation therapy (respiratory rate [RR] of > 30 breaths per minutes, PaCO2 > 55 mmHg and arterial pH success group and these parameters continued to improve even after four and 24 hours of NIPPV treatment. Out of 24 (24%) patients who failed to respond, 13 (54%) needed endotracheal intubation within one hour. The failure group had higher baseline HR than the success group. Improvement in HR, RR, pH, and PCO2 one hour after putting the patient on NIPPV predicts success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

  16. Prevalence of pre-high blood pressure and high blood pressure among non-overweight children and adolescents using international blood pressure references in developed regions in China.

    Science.gov (United States)

    Tian, Changwei; Xu, Shuang; Wang, Hua; Wang, Wenming; Shen, Hui

    2017-09-01

    There is a lack of data on the prevalence of pre-high blood pressure (PreHBP) and high blood pressure (HBP), based on recent international blood pressure references, in non-overweight children and adolescents. To describe the prevalence of PreHBP and HBP in non-overweight children and adolescents in developed regions of China. In total, 588 097 non-overweight children and adolescents aged 6-17 years from the National Surveys on Chinese Students' Constitution and Health in 2015 were included. The prevalence of PreHBP was 13.41% and subjects in urban areas had a higher prevalence of PreHBP (14.14%) than those in rural areas (12.92%). Subjects in regions with a high (13.56%) or moderate (13.61%) socioeconomic status showed a higher prevalence of PreHBP than those in regions with a relatively low socioeconomic status (12.76%). A similar pattern was found for the prevalence of HBP, and the prevalence of HBP was 18.25% for all participants, 20.55% for subjects in urban areas, 16.71% in rural areas, 18.76% in high socioeconomic areas, 18.62% in moderate socioeconomic areas and 16.70% in relatively low socioeconomic areas. A large proportion of non-overweight children and adolescents had elevated blood pressure and there were urban-rural and socioeconomic disparities in the prevalence of elevated blood pressure.

  17. Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study.

    Science.gov (United States)

    Head, Geoffrey A; Mihailidou, Anastasia S; Duggan, Karen A; Beilin, Lawrence J; Berry, Narelle; Brown, Mark A; Bune, Alex J; Cowley, Diane; Chalmers, John P; Howe, Peter R C; Hodgson, Jonathan; Ludbrook, John; Mangoni, Arduino A; McGrath, Barry P; Nelson, Mark R; Sharman, James E; Stowasser, Michael

    2010-04-14

    Twenty-four hour ambulatory blood pressure thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood pressure thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood pressure equivalents to clinic blood pressure thresholds for diagnosis and treatment of hypertension. We collated 24 hour ambulatory blood pressure data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood pressure measured by trained staff and in a smaller cohort by doctors (n=1693). Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood pressure 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood pressure and 10/5 mm Hg higher than 24 hour blood pressure, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/1 mm Hg lower in older people compared with the combined group. Our study provides daytime ambulatory blood pressure thresholds that are slightly lower than equivalent clinic values. Clinic blood pressure measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood pressure values.

  18. Blood Pressure Matters: Keep Hypertension in Check

    Science.gov (United States)

    ... 2016 Print this issue Blood Pressure Matters Keep Hypertension in Check En español Send us your comments ... 1 in 3 adults in the U.S. has high blood pressure, but many don’t realize it. High blood ...

  19. High Blood Pressure: Unique to Older Adults

    Science.gov (United States)

    ... our e-newsletter! Aging & Health A to Z High Blood Pressure Hypertension Unique to Older Adults This section provides ... Pressure Targets are Different for Very Old Adults High blood pressure (also called hypertension) increases your chance of having ...

  20. Cost-effectiveness of Intensive Blood Pressure Management

    DEFF Research Database (Denmark)

    Richman, Ilana B; Fairley, Michael; Jørgensen, Mads Emil

    2016-01-01

    Importance: Among high-risk patients with hypertension, targeting a systolic blood pressure of 120 mm Hg reduces cardiovascular morbidity and mortality compared with a higher target. However, intensive blood pressure management incurs additional costs from treatment and from adverse events......-effectiveness of intensive blood pressure management among 68-year-old high-risk adults with hypertension but not diabetes. We used the Systolic Blood Pressure Intervention Trial (SPRINT) to estimate treatment effects and adverse event rates. We used Centers for Disease Control and Prevention Life Tables to project age...... and accrued $155 261 in lifetime costs, while intensive management yielded 10.5 QALYs and accrued $176 584 in costs. Intensive blood pressure management cost $23 777 per QALY gained. In a sensitivity analysis, serious adverse events would need to occur at 3 times the rate observed in SPRINT and be 3 times...

  1. Non-invasive multiwavelength photoplethysmography under low partial pressure of oxygen.

    Science.gov (United States)

    Fang, Yung Chieh; Tai, Cheng-Chi

    2016-08-01

    A reduction in partial pressure of oxygen in the environment may be caused by a gain in altitude, which reduces the atmospheric pressure; it may also be caused by the carbon dioxide generated from breathing in an enclosed space. Does inhaling oxygen of lower partial pressure affect the oxygen-carrying function of haemoglobin in vivo? This study uses non-invasive multiwavelength photoplethysmography to measure the effects that inhaling this type of oxygen can have on the plethysmography of the appendages of the body (fingertips). The results indicate that under low partial pressure of oxygen, be it the result of a gain in carbon dioxide concentration or altitude, the change in visible light absorption is the biggest for short wavelengths (approximately 620 or 640 nm) near deoxyhaemoglobin, which has higher absorption coefficient. Moreover, increasing carbon dioxide concentration from 5000 to 10,000 ppm doubly reduces the absorption rate of these short wavelengths.

  2. Non-invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new application.

    Science.gov (United States)

    Sandberg, M; Zhang, Q; Styf, J; Gerdle, B; Lindberg, L-G

    2005-04-01

    To evaluate a specially developed photoplethysmographic (PPG) technique, using green and near-infrared light sources, for simultaneous non-invasive monitoring of skin and muscle perfusion. Evaluation was based on assessments of changes in blood perfusion to various provocations, such as post-exercise hyperaemia and hyperaemia following the application of liniment. The deep penetrating feature of PPG was investigated by measurement of optical radiation inside the muscle. Simultaneous measurements using ultrasound Doppler and the new PPG application were performed to elucidate differences between the two methods. Specific problems related to the influence of skin temperature on blood flow were highlightened, as well. Following static and dynamic contractions an immediate increase in muscle perfusion was shown, without increase in skin perfusion. Liniment application to the skin induced a rapid increase in skin perfusion, but not in muscle. Both similarities and differences in blood flow measured by Ultrasound Doppler and PPG were demonstrated. The radiant power measured inside the muscle, by use of an optical fibre, showed that the near-infrared light penetrates down to the vascular depth inside the muscle. The results of this study indicate the potentiality of the method for non-invasive measurement of local muscle perfusion, although some considerations still have to be accounted for, such as influence of temperature on blood perfusion.

  3. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  4. High Blood Pressure

    Science.gov (United States)

    ... factors Diabetes High blood pressure Family history Obesity Race/ethnicity Full list of causes and risk factors ... give Give monthly Memorials and tributes Donate a car Donate gently used items Stock donation Workplace giving ...

  5. High Blood Pressure

    Science.gov (United States)

    ... kidney disease, diabetes, or metabolic syndrome Read less Unhealthy lifestyle habits Unhealthy lifestyle habits can increase the risk of high blood pressure. These habits include: Unhealthy eating patterns, such as eating too much sodium ...

  6. Postural blood pressure electrocardiographic changes are associated with falls in older people.

    Science.gov (United States)

    Saedon, Nor Izzati; Zainal-Abidin, Imran; Chee, Kok Han; Khor, Hui Min; Tan, Kit Mun; Kamaruzzaman, Shahrul K; Chin, Ai-Vyrn; Poi, Philip J H; Tan, Maw Pin

    2016-02-01

    To determine the magnitude of postural blood pressure change, differences in ECG between fallers and non-fallers were measured. Postural blood pressure change is associated with symptoms of dizziness, presyncope, and syncope. In this cross-sectional study were included participants from The Malaysian Falls Assessment and Intervention Trial: fallers, aged 65 years or older with two or more falls or one injurious fall in 12 months, from a teaching hospital; and non-fallers, aged 65 years and older found through word-of-mouth and advertising. Noninvasive beat-to-beat blood pressure was measured at 10 min supine rest and 3 min standing. The maximal drop in systolic and diastolic pressure was calculated from a 12-lead ECG interpreted by a cardiologist. Basic demographics, medical history, and symptoms of dizziness, presyncope, and syncope were recorded for all patients. We recruited 155 fallers and 112 non-fallers. Fallers had a significantly longer PR interval (179 ± 32 vs. 168 ± 27 ms, p = 0.013) and a longer corrected QT interval (449 ± 41 vs. 443 ± 39 msec, p = 0.008), and larger change in SBP (28 ± 14 vs. 19 ± 9 mmHg, p < 0.001) with posture change. SBP drop of ≥30mmHg associated with recurrent and injurious falls [odds ratio [95 % confidence interval] = 7.61 (3.18-18.21)]. The changes remained significant after adjustment for symptoms of dizziness, presyncope and syncope. Older individuals with recurrent and injurious falls have significantly longer PR and QT intervals and larger SBP reduction with posture change as compared to non-fallers, and these are not explained by the presence of dizziness, presyncope, or syncope. SBP cut-off of ≥30mmHg considered for postural measurements using continuous BP monitors, the significance of this value needs to be evaluated.

  7. Optical sensor technology for a noninvasive continuous monitoring of blood components

    Science.gov (United States)

    Kraitl, Jens; Timm, Ulrich; Lewis, Elfed; Ewald, Hartmut

    2010-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) is used for a measurement of blood components. The absorptioncoefficient of blood differs at different wavelengths. This fact is used to calculate the optical absorbability characteristics of blood which is yielding information about blood components like hemoglobin (Hb), carboxyhemoglobin (CoHb) and arterial oxygen saturation (SpO2). The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. Hemoglobin is the main component of red blood cells. The primary function of Hb is the transport of oxygen from the lungs to the tissue and carbon dioxide back to the lungs. The Hb concentration in human blood is an important parameter in evaluating the physiological status of an individual and an essential parameter in every blood count. Currently, invasive methods are used to measure the Hb concentration, whereby blood is taken from the patient and subsequently analyzed. Apart from the discomfort of drawing blood samples, an added disadvantage of this method is the delay between the blood collection and its analysis, which does not allow real time patient monitoring in critical situations. A noninvasive method allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measured data.

  8. Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

    Science.gov (United States)

    Proença, Martin; Braun, Fabian; Solà, Josep; Thiran, Jean-Philippe; Lemay, Mathieu

    2017-06-01

    Current monitoring modalities for patients with pulmonary hypertension (PH) are limited to invasive solutions. A novel approach for the noninvasive and unsupervised monitoring of pulmonary artery pressure (PAP) in patients with PH was proposed and investigated. The approach was based on the use of electrical impedance tomography (EIT), a noninvasive and safe monitoring technique, and was tested through simulations on a realistic 4D bio-impedance model of the human thorax. Changes in PAP were induced in the model by simulating multiple types of hypertensive conditions. A timing parameter physiologically linked to the PAP via the so-called pulse wave velocity principle was automatically estimated from the EIT data. It was found that changes in PAP could indeed be reliably monitored by EIT, irrespective of the pathophysiological condition that caused them. If confirmed clinically, these findings could open the way for a new generation of noninvasive PAP monitoring solutions for the follow-up of patients with PH.

  9. Blood pressure in ICSI-conceived adolescents

    NARCIS (Netherlands)

    Belva, F.; Roelants, M.; de Schepper, J.; Roseboom, T. J.; Bonduelle, M.; Devroey, P.; Painter, R. C.

    2012-01-01

    Do young adolescents conceived by ICSI display a higher blood pressure than spontaneously conceived (SC) adolescents? In our study, 14-year-old male and female ICSI teenagers were not found to have increased blood pressure at rest. Only limited data are available regarding the cardiovascular risk of

  10. DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRES-SURE MONITORING

    Directory of Open Access Journals (Sweden)

    Mansoor Moazenzadeh

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: The study was conducted to define the determinants of suboptimal blood pressure (BP control among hypertensive patients under treatment and explore a predictive model for detecting the patients at risk for increased BP.    METHODS: We enrolled 97 patients (40 males, 57 females under treatment for hypertension between June 2006 and May 2007 in Shafa hospital, Kerman, Iran. BP was measured at clinic twice within 5-minute intervals. After setting up ambulatory blood pressure monitoring (ABPM, BP was measured at 30-minute intervals during the day and 60-minute intervals during the night. The frequency of increased BP (more than 140/90 mmHg was included in a regression model as dependent variable and all the others such as age, sex, body mass index (BMI, drugs and baseline clinical measurements as the predictors.    RESULTS: Increased BP was detected in 44% (95% CI: 38.79%-49.65% of all measurements during 24-hour monitoring. The frequency of increased BP had a significant relationship with BMI (b=0.35, P=0.001. Clinic's pulse pressure was a significant predicting factor for BP increase (P=0.02.    CONCLUSION: BMI and pulse pressure are the best predictors for being hypertensive during lifetime. Ineffective treatment of hypertension is frequent among the hypertensive patients.      Keywords: Blood pressure control, Pulse pressure, Ambulatory blood pressure monitoring (ABPM, BMI.

  11. Anxiety and blood pressure prior to dental treatment.

    NARCIS (Netherlands)

    Benjamins, C.; Schuurs, A.H.; Asscheman, H.; Hoogstraten, J.

    1990-01-01

    Assessed dental anxiety and blood pressure immediately prior to a dental appointment in 24 patients attending a university dental clinic or a clinic for anxious dental patients in the Netherlands. Blood pressure was assessed by 2 independent methods, and the interchangeability of the blood-pressure

  12. Dietary fiber and blood pressure control.

    Science.gov (United States)

    Aleixandre, A; Miguel, M

    2016-04-01

    In the past few years, new strategies to control blood pressure levels are emerging by developing new bioactive components of foods. Fiber has been linked to the prevention of a number of cardiovascular diseases and disorders. β-Glucan, the main soluble fiber component in oat grains, was initially linked to a reduction in plasma cholesterol. Several studies have shown afterward that dietary fiber may also improve glycaemia, insulin resistance and weight loss. The effect of dietary fiber on arterial blood pressure has been the subject of far fewer studies than its effect on the above-mentioned variables, but research has already shown that fiber intake can decrease arterial blood pressure in hypertensive rats. Moreover, certain fibers can improve arterial blood pressure when administered to hypertensive and pre-hypertensive subjects. The present review summarizes all those studies which attempt to establish the antihypertensive effects of dietary fiber, as well as its effect on other cardiovascular risk factors.

  13. Interarm difference in blood pressure

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels

    2014-01-01

    The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD). Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older...... without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women) with mean age of 72 years (range: 50-101) were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD) was present in 386 patients. Systolic blood pressure was 143 ± 24 mm......Hg and 142 ± 24 mmHg on the right and left arm, respectively (P = 0.015). The interarm difference was greater in patients with hypertension (P = 0.002) and PAD (P blood pressure was reproducible...

  14. Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Willerslev, Anne; Hansen, Mathias M; Klefter, Oliver Niels

    2017-01-01

    PURPOSE: To study the circulation in the retinal vessels in patients with blood dyscrasia due to myeloproliferative neoplasms using non-invasive retinal imaging. METHODS: Prospective consecutive case series of seven treatment-naïve patients with chronic myeloid leukaemia (n = 2), polycythemia vera...... present at baseline in patients with chronic myeloid leukaemia and were replaced by normal patterns at follow-up. Retinopathy, in the form of cotton-wool spots and retinal haemorrhages, was found at presentation in the two patients with chronic myeloid leukaemia and in one patient with polycythemia vera...

  15. Risk Stratification by Ambulatory Blood Pressure Monitoring Across JNC Classes of Conventional Blood Pressure

    DEFF Research Database (Denmark)

    Brguljan-Hitij, Jana; Thijs, Lutgarde; Li, Yan

    2014-01-01

    BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (<120/<80 mm Hg), prehypertension (120-139/80-89 mm Hg), and hypertension (≥140/≥90 mm Hg). METHODS: To assess the potential differential contribution of ambulatory blood pressure (ABP) in predict......BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (ABP......%) and of cardiovascular (-34%), cardiac (-33%), or cerebrovascular (-47%) events. Multivariable-adjusted hazard ratios (HRs) for stroke associated with 24-hour and daytime diastolic ABP (+5 mm Hg) were higher (P ≤ 0.045) in normotension than in prehypertension and hypertension (1.98 vs.1.19 vs.1.28 and 1.73 vs.1.09 vs. 1.......24, respectively) with similar trends (0.03 ≤ P ≤ 0.11) for systolic ABP (+10 mm Hg). However, HRs for fatal endpoints and cardiac events associated with ABP did not differ significantly (P ≥ 0.13) across CBP categories. Of normotensive and prehypertensive participants, 7.5% and 29.3% had masked hypertension...

  16. Blood pressure response to low level static contractions

    DEFF Research Database (Denmark)

    Fallentin, Nils; Jørgensen, Kurt

    1992-01-01

    The present study re-examines the 15% MVC concept, i.e. the existence of a circulatory steady-state in low intensity static contractions below 15% of maximal voluntary contraction (MVC). Mean arterial blood pressure was studied during static endurance contractions of the elbow flexor and extensor...... 0.7) min for elbow extension]. Mean arterial blood pressure exhibited a continuous and progressive increase during the 10% MVC contractions indicating that the 15% MVC concept would not appear to be valid. The terminal blood pressure value recorded at the point of exhaustion in the 10% MVC elbow...... the circulation to the muscles was arrested just prior to the cessation of the contraction, blood pressure only partly recovered and remained elevated for as long as the occlusion persisted, indicating the level of pressure-raising muscle chemoreflexes. Based on blood pressure recordings obtained during...

  17. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  18. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  19. High blood pressure in older subjects with cognitive impairment.

    Science.gov (United States)

    Mossello, Enrico; Simoni, David

    2016-06-22

    High blood pressure and cognitive impairment often coexist in old age, but their pathophysiological association is complex. Several longitudinal studies have shown that high blood pressure at midlife is a risk factor for cognitive impairment and dementia, although this association is much less clear in old age. The effect of blood pressure lowering in reducing the risk of dementia is only borderline significant in clinical trials of older subjects, partly due to the insufficient follow-up time. Conversely, dementia onset is associated with a decrease of blood pressure values, probably secondary to neurodegeneration. Prognostic effect of blood pressure values in cognitively impaired older subjects is still unclear, with aggressive blood pressure lowering being potentially harmful in this patients category. Brief cognitive screening, coupled with simple motor assessment, are warranted to identify frail older subjects who need a more cautious approach to antihypertensive treatment. Values obtained with ambulatory blood pressure monitoring seem more useful than clinical ones to predict the outcome of cognitively impaired older subjects. Future studies should identify the most appropriate blood pressure targets in older subjects with cognitive impairment.

  20. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  1. Dialysate magnesium level and blood pressure.

    Science.gov (United States)

    Kyriazis, John; Kalogeropoulou, Konstantina; Bilirakis, Leonidas; Smirnioudis, Nikolaos; Pikounis, Vasilios; Stamatiadis, Dimitrios; Liolia, Ekaterini

    2004-09-01

    We investigated the way dialysate magnesium (dMg) concentrations could affect blood pressure (BP) during hemodialysis (HD). Eight HD patients underwent four midweek HD treatments consecutively, using, during each four-hour HD session, one of the following four dialysate formulations, in randomized order, which differed only with regard to dMg and dialysate calcium (dCa) concentrations (in mmol/L): 0.75 dMg, 1.75 dCa (group I); 0.25 dMg, 1.75 dCa (group II); 0.75 dMg, 1.25 dCa (group III); 0.25 dMg, 1.25 dCa (group IV). Before HD and at four 60-minute intervals during the HD sessions, BP and noninvasive measurements of cardiac index (CI) were obtained. Additionally, 14 HD patients were treated for four weeks with 0.5 mmol/L dMg, followed by four weeks with 0.25 mmol/L dMg, and another four weeks with 0.75 mmol/L dMg, in random order. In all treatments dCa was 1.25 mmol/L. BP and symptoms were recorded during each HD session. Mean arterial pressure (MAP) decreased to a significantly (P dMg was superior to the other two treatments regarding intradialytic morbidity (P dMg level to 0.75 mmol/L could prevent IDH frequently seen with the use of 1.25 mmol/L dCa. Thus, manipulating dMg levels independently or in concert with dCa levels might have important implications with regard to dialysis tolerance.

  2. Blood Pressure Percentiles for School Children

    Directory of Open Access Journals (Sweden)

    İsmail Özanli

    2016-06-01

    Full Text Available Objective: The prevalence of hypertension in childhood and adolescence is gradually increasing. We aimed to in­vestigate the blood pressure (BP values of children aged 7-18 years. Methods: This study was conducted in a total of 3375 (1777 females, 1598 males children from 27 schools. Blood pressures of children were measured using sphyg­momanometer appropriate to arm circumference. Results: A positive relationship was found between sys­tolic blood pressure (SBP and diastolic blood pressure (DBP and the body weight, height, age and body mass index (BMI in male and female children. SBP was high­er in males than females after the age of 13. DBP was higher in males than the females after the age of 14. The mean annual increase of SBP was 2.06 mmHg in males and 1.54 mmHg in females. The mean annual increase of DBP was 1.52 mmHg in males and 1.38 mmHg in fe­males. Conclusion: In this study, we identified the threshold val­ues for blood pressure in children between the age of 7 and 18 years in Erzurum province. It is necessary to com­bine and evaluate data obtained from various regions for the identification of BP percentiles according to the age, gender and height percentiles of Turkish children.

  3. Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods.

    Science.gov (United States)

    Cardim, Danilo; Robba, Chiara; Donnelly, Joseph; Bohdanowicz, Michal; Schmidt, Bernhard; Damian, Maxwell; Varsos, Georgios V; Liu, Xiuyun; Cabeleira, Manuel; Frigieri, Gustavo; Cabella, Brenno; Smielewski, Peter; Mascarenhas, Sergio; Czosnyka, Marek

    2016-04-15

    Elevation of intracranial pressure (ICP) may occur in many diseases, and therefore the ability to measure it noninvasively would be useful. Flow velocity signals from transcranial Doppler (TCD) have been used to estimate ICP; however, the relative accuracy of these methods is unclear. This study aimed to compare four previously described TCD-based methods with directly measured ICP in a prospective cohort of traumatic brain-injured patients. Noninvasive ICP (nICP) was obtained using the following methods: 1) a mathematical "black-box" model based on interaction between TCD and arterial blood pressure (nICP_BB); 2) based on diastolic flow velocity (nICP_FVd); 3) based on critical closing pressure (nICP_CrCP); and 4) based on TCD-derived pulsatility index (nICP_PI). In time domain, for recordings including spontaneous changes in ICP greater than 7 mm Hg, nICP_PI showed the best correlation with measured ICP (R = 0.61). Considering every TCD recording as an independent event, nICP_BB generally showed to be the best estimator of measured ICP (R = 0.39; p area under the curve [AUC] = 0.66; p AUC (0.70; p AUC = 0.64; p > 0.05). nICP_PI was not related to measured ICP using any of the above statistical indicators. We also introduced a new estimator (nICP_Av) based on the average of three methods (nICP_BB, nICP_FVd, and nICP_CrCP), which overall presented improved statistical indicators (R = 0.47; p AUC = 0.73; p < 0.05). nICP_PI appeared to reflect changes in ICP in time most accurately. nICP_BB was the best estimator for ICP "as a number." nICP_Av demonstrated to improve the accuracy of measured ICP estimation.

  4. [Preventing Facial Pressure Injuries in Patients Who Use Noninvasive Positive Pressure Ventilators: The Efficiency of Dressings].

    Science.gov (United States)

    Tai, Chia-Hua; Hsu, Mei-Yu

    2016-10-01

    Noninvasive positive pressure ventilation (NPPV) provides ventilation without tracheal intubation. Facial pressure injury is a recognized complication of this technique, making the prevention of facial pressure injuries an important issue for NPPV patients. The present study compared the effects of foam dressing and hydrocolloid dressing in preventing facial pressure injuries in NPPV patients. A randomized clinical trial was used to evaluate participants that were referred from the intensive care unit of a medical center in eastern Taiwan. Participants were randomized into two groups: the foam dressing group and the hydrocolloid dressing group. Statistics used in analysis were: analysis mean, standard deviation, chi-square, independent t-test, and the generalized estimating equation. Sixty participants were enrolled as participants. The incidence rate of facial pressure injury was 11.7% (7/60). No significant difference was found between the two groups in terms of duration of NPPV use, incidence of facial pressure injury, and occurrence time of facial pressure injury. However, the hydrocolloid dressing group had a higher usage amount than the foam dressing group (p < .05). Foam and hydrocolloid dressings are both helpful in preventing facial pressure injury when used in conjunction with regular skin assessments.

  5. Determination of NIR informative wavebands for transmission non-invasive blood glucose measurement using a Fourier transform spectrometer

    Science.gov (United States)

    Yang, Wenming; Liao, Ningfang; Cheng, Haobo; Li, Yasheng; Bai, Xueqiong; Deng, Chengyang

    2018-03-01

    Non-invasive blood glucose measurement using near infrared (NIR) spectroscopy relies on wavebands that provide reliable information about spectral absorption. In this study, we investigated wavebands which are informative for blood glucose in the NIR shortwave band (900˜1450 nm) and the first overtone band (1450˜1700 nm) through a specially designed NIR Fourier transform spectrometer (FTS), which featured a test fixture (where a sample or subject's finger could be placed) and all-reflective optics, except for a Michelson structure. Different concentrations of glucose solution and seven volunteers who had undergone oral glucose tolerance tests (OGTT) were studied to acquire transmission spectra in the shortwave band and the first overtone band. Characteristic peaks of glucose absorption were identified from the spectra of glucose aqueous solution by second-order derivative processing. The wavebands linked to blood glucose were successfully estimated through spectra of the middle fingertip of OGTT participants by a simple linear regression and correlation coefficient. The light intensity difference showed that glucose absorption in the first overtone band was much more prominent than it was in the shortwave band. The results of the SLR model established from seven OGTTs in total on seven participants enabled a positive estimation of the glucose-linked wavelength. It is suggested that wavebands with prominent characteristic peaks, a high correlation coefficient between blood glucose and light intensity difference and a relatively low standard deviation of predicted values will be the most informative wavebands for transmission non-invasive blood glucose measurement methods. This work provides a guidance for waveband selection for the development of non-invasive NIR blood glucose measurement.

  6. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    Science.gov (United States)

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  7. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  8. Facial pressure zones of an oronasal interface for noninvasive ventilation: a computer model analysis

    Directory of Open Access Journals (Sweden)

    Luana Souto Barros

    2014-12-01

    Full Text Available OBJECTIVE: To study the effects of an oronasal interface (OI for noninvasive ventilation, using a three-dimensional (3D computational model with the ability to simulate and evaluate the main pressure zones (PZs of the OI on the human face. METHODS: We used a 3D digital model of the human face, based on a pre-established geometric model. The model simulated soft tissues, skull, and nasal cartilage. The geometric model was obtained by 3D laser scanning and post-processed for use in the model created, with the objective of separating the cushion from the frame. A computer simulation was performed to determine the pressure required in order to create the facial PZs. We obtained descriptive graphical images of the PZs and their intensity. RESULTS: For the graphical analyses of each face-OI model pair and their respective evaluations, we ran 21 simulations. The computer model identified several high-impact PZs in the nasal bridge and paranasal regions. The variation in soft tissue depth had a direct impact on the amount of pressure applied (438-724 cmH2O. CONCLUSIONS: The computer simulation results indicate that, in patients submitted to noninvasive ventilation with an OI, the probability of skin lesion is higher in the nasal bridge and paranasal regions. This methodology could increase the applicability of biomechanical research on noninvasive ventilation interfaces, providing the information needed in order to choose the interface that best minimizes the risk of skin lesion.

  9. Diagnosis of childhood hypertension: is blood pressure height ratio ...

    African Journals Online (AJOL)

    Blood pressure was also recorded according to the standard method. Systolic and diastolic blood pressure to height ratio were then calculated. Receiver operating curves was used to assess the ability of systolic blood and diastolic blood pressure height ratio to discriminate childhood prehypertension and hypertension.

  10. How to Prevent High Blood Pressure: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish Understanding Blood Pressure Readings (American Heart Association) Weightlifting: Bad for Your Blood Pressure? (Mayo Foundation for ... High Blood Pressure High Blood Pressure in Pregnancy Nutrition Quitting Smoking Stress National Institutes of Health The ...

  11. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  12. 24 hr non-invasive ambulatory blood pressure and heart rate monitoring in Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    Eva eStübner

    2013-05-01

    Full Text Available Non-motor symptoms are now commonly recognized in Parkinson’s Disease (PD and can include dysautonomia. Impairment of cardiovascular autonomic function can occur at any stage of PD but is typically prevalent in advanced stages or related to (anti-parkinsonian drugs and can result in atypical blood pressure (BP readings and related symptoms such as orthostatic hypotension (OH and supine hypertension. OH is usually diagnosed with a head-up-tilt test (HUT or an (active standing test (also known as Schellong test in the laboratory, but 24 hour Ambulatory Blood Pressure Monitoring (ABPM in a home setting may have several advantages, such as providing an overview of symptoms in daily life alongside pathophysiology as well as assessment of treatment interventions. This, however, is only possible if ABPM is administrated correctly and an autonomic protocol (including a diary is followed. which will be discussed in this review. A 24hr ABPM does not only allow the detection of OH, if it is present, but also the assessment of cardiovascular autonomic dysfunction during and after various daily stimuli, such as postprandial and alcohol dependent hypotension, as well as exercise and drug induced hypotension. Furthermore, information about the circadian rhythm of BP and heart rate (HR can be obtained and establish whether or not a patient has a fall of BP at night (i.e. ‘dipper’ vs. non-‘dipper’. The information about nocturnal BP may also allow the investigation or detection of disorders such as sleep dysfunction, nocturnal movement disorders and obstructive sleep apnea, which are common in PD. Additionally, a 24hr ABPM should be conducted to examine the effectiveness of OH therapy. This review will outline the methodology of 24 hr ABPM in PD, summarize findings of such studies in PD and briefly consider common daily stimuli that might affect 24 Hr ABPM.

  13. Comparison of noninvasive assessments of central blood pressure using general transfer function and late systolic shoulder of the radial pressure wave.

    Science.gov (United States)

    Wohlfahrt, Peter; Krajcoviechová, Alena; Seidlerová, Jitka; Mayer, Otto; Filipovsky, Jan; Cífková, Renata

    2014-02-01

    Central systolic blood pressure (cSBP) can be derived by the general transfer function of the radial pressure wave, as used in the SphygmoCor device, or by regression equation from directly measured late systolic shoulder of the radial pressure wave (pSBP2), as used in the Omron HEM-9000AI device. The aim of this study was to compare the SphygmoCor estimates of cSBP with 2 estimates of cSBP provided by the Omron HEM-9000AI (cSBP, pSBP2) in a large cohort of the white population. In 391 patients aged 52.3±13.5 years (46% men) from the Czech post-MONICA Study, cSBP was measured using the SphygmoCor and Omron HEM-9000AI devices in random order. Omron cSBP and pSBP2 were perfectly correlated (r = 1.0; P wave provides a comparable accuracy with the validated general transfer function. When comparing Omron HEM-9000AI and SphygmoCor estimates of cSBP, Omron pSBP2 should be used. The difference between both devices in cSBP may be explained by differences in calibration.

  14. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    Science.gov (United States)

    Karmali, Kunal N; Lloyd-Jones, Donald M; van der Leeuw, Joep; Goff, David C; Yusuf, Salim; Zanchetti, Alberto; Glasziou, Paul; Jackson, Rodney; Woodward, Mark; Rodgers, Anthony; Neal, Bruce C; Berge, Eivind; Teo, Koon; Davis, Barry R; Chalmers, John; Pepine, Carl; Rahimi, Kazem; Sundström, Johan

    2018-03-01

    Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD) prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP) level. We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC) from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants). During a median of 4.0 y of follow-up, 3,566 participants (7.5%) experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI) 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy). Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31%) fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18%) more events for the same number of persons treated. Compared with treating

  15. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    Directory of Open Access Journals (Sweden)

    Kunal N Karmali

    2018-03-01

    Full Text Available Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP level.We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants. During a median of 4.0 y of follow-up, 3,566 participants (7.5% experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy. Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31% fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18% more events for the same number of persons treated. Compared with

  16. Caffeine: How Does It Affect Blood Pressure?

    Science.gov (United States)

    ... naturally increase your blood pressure, such as exercise, weightlifting or hard physical labor. To see if caffeine ... blood pressure and stress indices in healthy individuals. Nutrition Journal. 2016;15:26. Cano-Marquina A, et ...

  17. Ambulatory blood pressure monitoring - comparison with office ...

    African Journals Online (AJOL)

    ambulatory blood pressure recordings in private practice ... position according to established guidelines. ... white-coat effect was defined as a difference of at least 20 .... patients with hypertension: Importance of blood pressure response to ...

  18. Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT.

    Science.gov (United States)

    Vaduganathan, Muthiah; Pareek, Manan; Qamar, Arman; Pandey, Ambarish; Olsen, Michael H; Bhatt, Deepak L

    2018-02-05

    The 2017 American College of Cardiology (ACC)/American Heart Association (AHA) guidelines include lower thresholds to define hypertension than previous guidelines. Little is known about the impact of these guideline changes in patients with or at high risk for cardiovascular disease. In this exploratory analysis using baseline blood pressure assessments in Systolic Blood Pressure Intervention Trial (SPRINT), we evaluated the prevalence and associated cardiovascular prognosis of patients newly reclassified with hypertension based on the 2017 ACC/AHA (systolic blood pressure ≥130 mm Hg or diastolic blood pressure ≥80 mm Hg) compared with the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood Pressure (JNC 7) guidelines (systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg). The primary endpoint was the composite of myocardial infarction, other acute coronary syndromes, stroke, heart failure, or cardiovascular death. In 4683 patients assigned to the standard treatment arm of SPRINT, 2328 (49.7%) met hypertension thresholds by JNC 7 guidelines, and another 1424 (30.4%) were newly reclassified as having hypertension based on the 2017 ACC/AHA guidelines. Over 3.3-year median follow-up, 319 patients experienced the primary endpoint (87 of whom were newly reclassified with hypertension based on the revised guidelines). Patients with hypertension based on prior guidelines compared with those newly identified with hypertension based on the new guidelines had similar risk of the primary endpoint (2.3 [95% confidence interval {CI}, 2.0-2.7] vs 2.0 [95% CI, 1.6-2.4] events per 100 patient-years; adjusted HR, 1.10 [95% CI, 0.84-1.44]; P = .48). The 2017 ACC/AHA high blood pressure guidelines are expected to significantly increase the prevalence of patients with hypertension (perhaps to a greater extent in higher-risk patient cohorts compared with the general population) and

  19. Non-invasive estimation of pulsatile flow and differential pressure in an implantable rotary blood pump for heart failure patients

    International Nuclear Information System (INIS)

    AlOmari, A H; Savkin, A V; Karantonis, D M; Lim, E; Lovell, N H

    2009-01-01

    We propose dynamical models for pulsatile flow and head estimation in an implantable rotary blood pump. Pulsatile flow and head data were obtained using a circulatory mock loop where fluid solutions with different values of viscosities were used as a blood analogue with varying haematocrit (HCT). Noninvasive measurements of power and pump speed were used with HCT values as inputs to the flow model while the estimated flow was used with the speed as inputs to a head estimation model. Linear regression analysis between estimated and measured flows obtained from a mock loop resulted in a highly significant correlation (R 2 = 0.982) and a mean absolute error (e) of 0.323 L min −1 , while for head, R 2 = 0.933 and e = 7.682 mmHg were obtained. R 2 = 0.849 and e = 0.584 L min −1 were obtained when the same model derived in the mock loop was used for flow estimation in ex vivo porcine data (N = 6). Furthermore, in the steady state, the solution of the presented flow model can be described by a previously designed and verified static model. The models developed herein will play a vital role in developing a robust control system of the pump flow coping with changing physiological demands

  20. Assessment of baroreflex sensitivity from spontaneous oscillations of blood pressure and heart rate: proven clinical value?

    International Nuclear Information System (INIS)

    Pinna, Gian Domenico; Maestri, Roberto; La Rovere, Maria Teresa

    2015-01-01

    The baroreceptor-heart rate reflex (baroreflex sensitivity, BRS) is a key mechanism contributing to the neural regulation of the cardiovascular system. Several methods have been proposed so far to assess BRS by analyzing the spontaneous beat-to-beat fluctuations of arterial blood pressure and heart rate. These methods are inherently simple, non-invasive and low-cost. This study is an attempt to address the question of whether spontaneous baroreflex methods have proven to be of value in the clinical setting. In the first part of this article, we critically review most representative clinical studies using spontaneous BRS techniques either for risk stratification or treatment evaluation, these being major issues in the clinical management of the patients. In the second part, we address two important aspects of spontaneous BRS measurements: measurability and reliability. Estimation of BRS in the studies selected for the review was performed according to the sequence, transfer function, alpha-index and phase-rectified signal averaging method. Arterial blood pressure was recorded non-invasively during supine, short-term (<30 min) laboratory recordings. The conclusion from this review is that spontaneous BRS techniques have been shown to be of great value in clinical practice but further work is needed to confirm the validity of previous findings and to widen the field of clinical applications. Measurability and reliability can be a major issue in the measurement of spontaneous BRS, particularly in some patient populations like post-myocardial infarction and heart failure patents. Main causes of poor measurability are: non-sinus rhythm, a high rate of ectopic beats and the need for recorded time series of RR interval and arterial blood pressure to satisfy the constraints of the different BRS estimation algorithms. As for reliability, within-subject variability is rather high in the measurements of spontaneous BRS and, therefore, should be carefully taken into account

  1. [Central blood pressure and vascular damage].

    Science.gov (United States)

    Pérez-Lahiguera, Francisco; Rodilla, Enrique; Costa, José Antonio; Pascual, José María

    2015-07-20

    The aim of this study was to assess the relationship between central blood pressure and vascular damage. This cross-sectional study involved 393 never treated hypertensive patients (166 women). Clinical blood pressure (BP), 24h blood pressure (BP24h) and central blood pressure (CBP) were measured. Vascular organ damage (VOD) was assessed by calculating the albumin/creatinine ratio (ACR), wave pulse pressure velocity and echocardiographic left ventricular mass index (LVMI). Patients with VOD had higher values of BP, BP24h, and CBP than patients without ACR. When comparing several systolic BP, systolic BP24h had a higher linear correlation with CBP (Z Steiger test: 2.26; P=.02) and LVMI (Z Steiger test: 3.23; P=.01) than PAC. In a multiple regression analysis corrected by age, sex and metabolic syndrome, all pressures were related with VOD but systolic BP24h showed the highest correlation. In a logistic regression analysis, having the highest tercile of systolic BP24h was the stronger predictor of VOD (multivariate odds ratio: 3.4; CI 95%: 2.5-5.5, P=.001). CBP does not have more correlation with VOD than other measurements of peripheral BP. Systolic BP24h is the BP measurement that best predicts VOD. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  2. Association of betaine with blood pressure in dialysis patients.

    Science.gov (United States)

    Wang, Lulu; Zhao, Mingming; Liu, Wenjin; Li, Xiurong; Chu, Hong; Bai, Youwei; Sun, Zhuxing; Gao, Chaoqing; Zheng, Lemin; Yang, Junwei

    2018-02-01

    Mechanisms underlying elevated blood pressure in dialysis patients are complex as a variety of non-traditional factors are involved. We sought to explore the association of circulating betaine, a compound widely distributed in food, with blood pressure in dialysis patients. We used baseline data of an ongoing cohort study involving patients on hemodialysis. Plasma betaine was measured by high performance liquid chromatography in 327 subjects. Blood pressure level was determined by intradialytic ambulatory blood pressure monitoring. The mean age of the patients was 52.6 ± 11.9 years, and 58.4% were male. Average interdialytic ambulatory systolic and diastolic blood pressure were 138.4 ± 22.7 mm Hg and 84.4 ± 12.5 mm Hg, respectively. Mean plasma betaine level was 37.6 μmol/L. Multiple linear regression analysis revealed significant associations of betaine with both systolic blood pressure (β = -3.66, P = .003) and diastolic blood pressure (β = -2.00, P = .004). The associations persisted even after extensive adjustment for cardiovascular covariates. Subgroup analysis revealed that the association between betaine and blood pressure was mainly limited to female patients. Our data suggest that alteration of circulating betaine possibly contributes to blood pressure regulation in these patients. ©2018 Wiley Periodicals, Inc.

  3. Stress and High Blood Pressure: What's the Connection?

    Science.gov (United States)

    Stress and high blood pressure: What's the connection? Stress and long-term high blood pressure may not be linked, but taking steps to reduce your stress can improve your general health, including your blood ...

  4. Calcium Supplements: Do They Interfere with Blood Pressure Drugs?

    Science.gov (United States)

    ... with blood pressure drugs? Is it true that calcium supplements may interact with blood pressure medications? Answers ... G. Sheps, M.D. Yes. In large amounts, calcium supplements may interact with some blood pressure medications. ...

  5. Snapshot: Blood Pressure in the U.S.

    Science.gov (United States)

    ... please visit this page: About CDC.gov . Home Blood Pressure: Make Control Your Goal Infographic Recommend on Facebook ... Compartir Copy the code below to use the Blood Pressure Infographic on your web page or social media ...

  6. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Goat Meat Does Not Cause Increased Blood Pressure

    Directory of Open Access Journals (Sweden)

    Katsunori Sunagawa

    2014-01-01

    Full Text Available While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g were evenly separated into 4 groups. The control group (CP was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan/salt group (GY was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (p<0.01 than the CP and GM groups despite the fact that their diet consumption levels were similar. The body weight of animals in the CP, GM, and GS groups was similar while the animals in the GY group were significantly smaller (p<0.01. The blood pressure in the GM group was virtually the same as the CP group throughout the course of the experiment. In contrast, while the blood pressure of the animals in the GS and GY group from 15 to 19 weeks old was the same as the CP group, their blood pressures were significantly higher (p<0.01 after 20 weeks of age. The GY group tended to have lower blood pressure than the GS group. In experiment 2, in order to clarify whether or not the increase in blood pressure in the GS group and the GY group in experiment 1 was caused by an excessive intake of salt, the effects on blood pressure of a reduction of salt in diet were investigated. When amount of salt in the diet of the GS and GY group was reduced from 4% to 0.3%, the animal

  8. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  9. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial

    DEFF Research Database (Denmark)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter

    2018-01-01

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark....... One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent...... a reduction of blood pressure. Clinical Trials NCT00244660....

  10. Ocular Blood Flow Measured Noninvasively in Zero Gravity

    Science.gov (United States)

    Ansari, Rafat R.; Manuel, Francis K.; Geiser, Martial; Moret, Fabrice; Messer, Russell K.; King, James F.; Suh, Kwang I.

    2003-01-01

    In spaceflight or a reduced-gravity environment, bodily fluids shift to the upper extremities of the body. The pressure inside the eye, or intraocular pressure, changes significantly. A significant number of astronauts report changes in visual acuity during orbital flight. To date this remains of unknown etiology. Could choroidal engorgement be the primary mechanism and a change in the curvature or shape of the cornea or lens be the secondary mechanism for this change in visual acuity? Perfused blood flow in the dense meshwork of capillaries of the choroidal tissue (see the preceding illustration) provides necessary nutrients to the outer layers of the retina (photoreceptors) to keep it healthy and maintain good vision. Unlike the vascular system, the choroid has no baroreceptors to autoregulate fluid shifts, so it can remain engorged, pushing the macula forward and causing a hyperopic (farsighted) shift of the eye. Experiments by researchers at the NASA Glenn Research Center could help answer this question and facilitate planning for long-duration missions. We are investigating the effects of zero gravity on the choroidal blood flow of volunteer subjects. This pilot project plans to determine if choroidal blood flow is autoregulated in a reduced-gravity environment.

  11. Can Whole-Grain Foods Lower Blood Pressure?

    Science.gov (United States)

    ... eating more whole-grain foods help lower my blood pressure? Answers from Sheldon G. Sheps, M.D. It might. Eating ... might help reduce your chance of developing high blood pressure (hypertension). Whole grains are grains that include the ...

  12. Tissue Damage Characterization Using Non-invasive Optical Modalities

    Science.gov (United States)

    Diaz, David

    The ability to determine the degree of cutaneous and subcutaneous tissue damage is essential for proper wound assessment and a significant factor for determining patient treatment and morbidity. Accurate characterization of tissue damage is critical for a number of medical applications including surgical removal of nonviable tissue, severity assessment of subcutaneous ulcers, and depth assessment of visually open wounds. The main objective of this research was to develop a non-invasive method for identifying the extent of tissue damage underneath intact skin that is not apparent upon visual examination. This work investigated the relationship between tissue optical properties, blood flow, and tissue viability by testing the hypotheses that (a) changes in tissue oxygenation and/or microcirculatory blood flow measurable by Diffuse Near Infrared Spectroscopy (DNIRS) and Diffuse Correlation Spectroscopy (DCS) differ between healthy and damaged tissue and (b) the magnitude of those changes differs for different degrees of tissue damage. This was accomplished by developing and validating a procedure for measuring microcirculatory blood flow and tissue oxygenation dynamics at multiple depths (up to 1 centimeter) using non-invasive DCS and DNIRS technologies. Due to the lack of pressure ulcer animal models that are compatible with our optical systems, a proof of concept was conducted in a porcine burn model prior to conducting clinical trials in order to assess the efficacy of the system in-vivo. A reduction in total hemoglobin was observed for superficial (5%) and deep burns (35%) along with a statistically significant difference between the optical properties of superficial and deep burns (p differences detected in optical properties and hemoglobin content by optical measurements correlated with the extent of tissue injury observed in histological stains. After proof of concept in animals, a human study was conducted and optical data was collected from 20 healthy

  13. Managing Stress to Control High Blood Pressure

    Science.gov (United States)

    ... Aortic Aneurysm More Managing Stress to Control High Blood Pressure Updated:Jan 29,2018 The importance of stress ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  14. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  15. Correlates of blood pressure in Yanomami Indians of northwestern Brazil.

    Science.gov (United States)

    Crews, D E; Mancilha-Carvalho, J J

    1993-01-01

    We determined associations of measures of body habitus with blood pressure for 100 adult Yanomami Indians (61 men, 39 women) examined during February and March 1990. Measurements included body weight and height, four skinfolds (triceps, subscapular, suprailiac, abdomen), four circumferences (wrist, upper arm, abdomen, hip), systolic and diastolic blood pressures, pulse rate, and estimated age. Various indices of fat distribution were determined from the measurements of skinfolds, circumferences, weight, and height. Estimated age averaged 35.0 years in men and 33.4 years in women (range: 15 to 63 years). Mean systolic and diastolic blood pressures were low in both men (104.8/70.4 mm Hg) and women (94.8/63.5 mm Hg), as was body mass index (men: 20.7; women: 21.4 kg/m2). In Yanomami women, all four skinfolds, wrist circumference, and the indices of hip and abdominal fat were significant correlates of systolic blood pressure, while the abdominal skinfold and wrist and hip circumferences correlated significantly with diastolic blood pressure. Among men, there was a negative correlation between estimated age and systolic blood pressure and a positive correlation between BMI and upper arm and hip circumferences and systolic blood pressure. There was a significant positive correlation between wrist, upper arm, and hip circumferences and diastolic blood pressure among Yanomami men. We used stepwise regression to generate sex-specific predictive equations for blood pressure. For men, estimated age and hip circumference, and for women, abdominal skinfold measurement and age were included in the model for systolic blood pressure. Among men, wrist circumference and height, and among women, wrist circumference alone entered the model for diastolic blood pressure. On the basis of these results, we suggest that even in a low-blood pressure, low-body fat, no-salt setting, systolic blood pressure is associated with the amount and placement of adipose tissue. However, diastolic blood

  16. Parametrically defined cerebral blood vessels as non-invasive blood input functions for brain PET studies

    International Nuclear Information System (INIS)

    Asselin, Marie-Claude; Cunningham, Vincent J; Amano, Shigeko; Gunn, Roger N; Nahmias, Claude

    2004-01-01

    A non-invasive alternative to arterial blood sampling for the generation of a blood input function for brain positron emission tomography (PET) studies is presented. The method aims to extract the dimensions of the blood vessel directly from PET images and to simultaneously correct the radioactivity concentration for partial volume and spillover. This involves simulation of the tomographic imaging process to generate images of different blood vessel and background geometries and selecting the one that best fits, in a least-squares sense, the acquired PET image. A phantom experiment was conducted to validate the method which was then applied to eight subjects injected with 6-[ 18 F]fluoro-L-DOPA and one subject injected with [ 11 C]CO-labelled red blood cells. In the phantom study, the diameter of syringes filled with an 11 C solution and inserted into a water-filled cylinder were estimated with an accuracy of half a pixel (1 mm). The radioactivity concentration was recovered to 100 ± 4% in the 8.7 mm diameter syringe, the one that most closely approximated the superior sagittal sinus. In the human studies, the method systematically overestimated the calibre of the superior sagittal sinus by 2-3 mm compared to measurements made in magnetic resonance venograms on the same subjects. Sources of discrepancies related to the anatomy of the blood vessel were found not to be fundamental limitations to the applicability of the method to human subjects. This method has the potential to provide accurate quantification of blood radioactivity concentration from PET images without the need for blood samples, corrections for delay and dispersion, co-registered anatomical images, or manually defined regions of interest

  17. Effects of parental smoking on exercise systolic blood pressure in adolescents.

    Science.gov (United States)

    Hacke, Claudia; Weisser, Burkhard

    2015-05-11

    In adults, exercise blood pressure seems to be more closely related to cardiovascular risk than resting blood pressure; however, few data are available on the effects of familial risk factors, including smoking habits, on exercise blood pressure in adolescents. Blood pressure at rest and during exercise, parental smoking, and other familial risk factors were investigated in 532 adolescents aged 12 to 17 years (14.6±1.5 years) in the Kiel EX.PRESS. (EXercise PRESSure) Study. Exercise blood pressure was determined at 1.5 W/kg body weight using a standardized submaximal cycle ergometer test. Mean resting blood pressure was 113.1±12.8/57.2±7.1 mm Hg, and exercise blood pressure was 149.9±19.8/54.2±8.6 mm Hg. Parental smoking increased exercise systolic blood pressure (+4.0 mm Hg, 3.1 to 4.9; P=0.03) but not resting blood pressure of the subjects (adjusted for age, sex, height, body mass index percentile, fitness). Parental overweight and familial hypertension were related to both higher resting and exercise systolic blood pressure values, whereas associations with an inactive lifestyle and a low educational level of the parents were found only with adolescents' blood pressure during exercise. The cumulative effect of familial risk factors on exercise systolic blood pressure was more pronounced than on blood pressure at rest. Parental smoking might be a novel risk factor for higher blood pressure, especially during exercise. In addition, systolic blood pressure during a submaximal exercise test was more closely associated with familial risk factors than was resting blood pressure, even in adolescents. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. Central Pressure Appraisal: Clinical Validation of a Subject-Specific Mathematical Model.

    Directory of Open Access Journals (Sweden)

    Francesco Tosello

    Full Text Available Current evidence suggests that aortic blood pressure has a superior prognostic value with respect to brachial pressure for cardiovascular events, but direct measurement is not feasible in daily clinical practice.The aim of the present study is the clinical validation of a multiscale mathematical model for non-invasive appraisal of central blood pressure from subject-specific characteristics.A total of 51 young male were selected for the present study. Aortic systolic and diastolic pressure were estimated with a mathematical model and were compared to the most-used non-invasive validated technique (SphygmoCor device, AtCor Medical, Australia. SphygmoCor was calibrated through diastolic and systolic brachial pressure obtained with a sphygmomanometer, while model inputs consist of brachial pressure, height, weight, age, left-ventricular end-systolic and end-diastolic volumes, and data from a pulse wave velocity study.Model-estimated systolic and diastolic central blood pressures resulted to be significantly related to SphygmoCor-assessed central systolic (r = 0.65 p <0.0001 and diastolic (r = 0.84 p<0.0001 blood pressures. The model showed a significant overestimation of systolic pressure (+7.8 (-2.2;14 mmHg, p = 0.0003 and a significant underestimation of diastolic values (-3.2 (-7.5;1.6, p = 0.004, which imply a significant overestimation of central pulse pressure. Interestingly, model prediction errors mirror the mean errors reported in large meta-analysis characterizing the use of the SphygmoCor when non-invasive calibration is performed.In conclusion, multi-scale mathematical model predictions result to be significantly related to SphygmoCor ones. Model-predicted systolic and diastolic aortic pressure resulted in difference of less than 10 mmHg in the 51% and 84% of the subjects, respectively, when compared with SphygmoCor-obtained pressures.

  19. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  20. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial.

    Science.gov (United States)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter; Gregers Petersen, Hans; Benee Olsen, David; Berg, Ronan M G; Abrahamsen, Henrik; Wiinberg, Niels

    2018-01-17

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark. One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent home blood pressure monitoring and 24-hour ambulatory blood pressure monitoring. Mean day- and night-time systolic and diastolic 24-hour ambulatory blood pressure. Change in systolic and diastolic office blood pressure and change in cardiovascular risk profile. Of the patients, 515 (49%) were allocated to the usual group, and 533 (51%) to the intensive group. The reductions in day- and night-time 24-hour ambulatory blood pressure were similar (usual group: 4.6 ± 13.5/2.8 ± 82 mmHg; intensive group: 5.6 ± 13.0/3.5 ± 8.2 mmHg; P = 0.27/P = 0.20). Cardiovascular risk scores were reduced in both groups at follow-up, but more so in the intensive than in the usual group (P = 0.02). An intensive blood pressure monitoring strategy led to a similar blood pressure reduction to conventional monitoring. However, the intensive strategy appeared to improve patients' cardiovascular risk profile through other effects than a reduction of blood pressure. Clinical Trials NCT00244660. © The Author 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Relationship between blood lead, blood pressure, stroke, and heart attacks in middle-aged British men

    International Nuclear Information System (INIS)

    Pocock, S.J.; Shaper, A.G.; Ashby, D.; Delves, H.T.; Clayton, B.E.

    1988-01-01

    The relationship between blood lead concentration and blood pressure is examined in a survey of 7371 men aged 40 to 59 from 24 British towns. After allowance for relevant confounding variables, including town of residence and alcohol consumption, there exists a very weak but statistically significant positive association between blood lead and both systolic and diastolic blood pressure. After 6 years of follow-up, 316 of these men had major ischemic heart disease, and 66 had a stroke. After allowance for the confounding effects of cigarette smoking and town of residence there is no evidence that blood lead is a risk factor for these cardiovascular events. However, as the blood lead-blood pressure association is so weak, it is unlikely that any consequent association between lead and cardiovascular disease could be demonstrated from prospective epidemiological studies. An overview of data from this and other large epidemiological surveys provides reasonable consistent evidence on lead and blood pressure. While NHANES II data on 2254 US men indicate a slightly stronger association between blood lead and systolic blood pressure, data from two Welsh studies on over 2000 men did not show a statistically significant association. Nevertheless, such statistical association cannot be taken as establishing a causal effect of low-level lead exposure on blood pressure

  2. Worldwide trends in blood pressure from 1975 to 2015

    NARCIS (Netherlands)

    Ezzati, Majid; Geleijnse, J.M.

    2017-01-01

    Background

    Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic

  3. Teaming Up Against High Blood Pressure PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    Nearly one-third of American adults have high blood pressure, and more than half of them don’t have it under control. Simply seeing a doctor and taking medications isn’t enough for many people who have high blood pressure. A team-based approach by patients, health care systems, and health care providers is one of the best ways to treat uncontrolled high blood pressure.

  4. Side effects of ambulatory blood pressure monitoring.

    NARCIS (Netherlands)

    Steen, M.S. van der; Lenders, J.W.M.; Thien, Th.

    2005-01-01

    OBJECTIVE: To study the experiences and complaints of patients who underwent 24 h blood pressure monitoring. METHODS: Two groups of hypertensive patients of a tertiary outpatient clinic were asked to fill in a nine-item questionnaire about the side effects of ambulatory blood pressure monitoring

  5. A common humoral background of intraocular and arterial blood pressure dysregulation.

    Science.gov (United States)

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  6. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    Science.gov (United States)

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  7. NONINVASIVE MEASUREMENT OF INTRARENAL BLOOD-FLOW DISTRIBUTION - KINETIC-MODEL OF RENAL I-123 HIPPURAN HANDLING

    NARCIS (Netherlands)

    JANSSEN, WMT; BEEKHUIS, H; DEBRUIN, R; DEJONG, PE; DEZEEUW, D

    1995-01-01

    A new technique for noninvasive measurement of intrarenal blood flow distribution over cortex and medulla is proposed. The tech nique involves analysis of I-123-labeled hippuran renography, according to a kinetic model that describes the flow of I-123- hippuran from the heart (input) through the

  8. Noninvasive biosensor and wireless interrogating system for glucose in blood

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.

    2003-07-01

    Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.

  9. Increased nocturnal blood pressure in enuretic children with polyuria.

    Science.gov (United States)

    Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian

    2009-10-01

    We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.

  10. [Blood pressure variability: clinical interest or simple curiosity?].

    Science.gov (United States)

    Ciaroni, Stefano

    2007-03-14

    Blood pressure variability is a physiological phenomenon influenced by many internal and external factors. This variability could be also influenced by pathological conditions such as arterial hypertension. Two forms must be mainly distinguished: the blood pressure variability at long and short-term. The latter could only be studied by continuous recordings. In this article will be analysed the interest of measuring blood pressure variability, its cardiovascular prognosis and the therapeutic tools when it is increased.

  11. Blood pressure as a therapeutic target in stroke.

    Science.gov (United States)

    Armario, Pedro; de la Sierra, Alejandro

    2009-01-01

    Stroke, as a clinical manifestation of the cardiovascular diseases, is one of the leading causes of death and disability in both developed and developing countries. Hypertension is by far, the most important risk factor for stroke. Epidemiological data indicate that the risk of stroke increases with both systolic and diastolic blood pressure elevation, from levels of 115/75 mmHg. It is also evident that most adults worldwide have values above these limits, thus emphasizing the importance of blood pressure as a risk factor for stroke. Clinical trials of antihypertensive treatment, both in studies that have compared active drugs against placebo or in those comparing different types of drugs have clearly demonstrated a protective effect of blood pressure reduction in the prevention of stroke. The degree of protection is directly related to blood pressure reduction and, the lower the level, the better the prognosis. Although data on secondary stroke prevention are scarcer, studies also seem to indicate that lowering blood pressure with antihypertensive treatment protects against stroke recurrence. At the present moment there is still uncertainty on 2 different aspects regarding the relationship between antihypertensive treatment and stroke. First, the blood pressure management during acute stroke has not adequately investigated in clinical trials. Second, the possibility of a protective role of specific types of antihypertensive drugs beyond blood pressure reduction is a matter of debate. Independently of these unresolved issues, prevention of hypertension development by lifestyle changes and adequate treatment and control to the hypertensive population will be a very effective measure in reducing stroke incidence, stroke recurrence, and stroke mortality.

  12. A study on new method of noninvasive esophageal venous pressure measurement based on the airflow and laser detection technology.

    Science.gov (United States)

    Hu, Chenghuan; Huang, Feizhou; Zhang, Rui; Zhu, Shaihong; Nie, Wanpin; Liu, Xunyang; Liu, Yinglong; Li, Peng

    2015-01-01

    Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed pump and a laser emitting apparatus could generate optical signals which can be captured by image acquisition and analysis system program. A synchronization system simultaneous measured the changes of air pressure and the deformation of the vein wall to capture the vascular deformation while simultaneously record the current pressure value. The results of this study indicated that the pressure values tested by the new method have good correlation with the actual pressure value in animal experiments. The new method of noninvasive pressure measurement based on the airflow and laser detection technology is accurate, feasible, repeatable and has a good application prospects.

  13. Dietary protein and blood pressure : epidemiological studies

    NARCIS (Netherlands)

    Altorf-van der Kuil, W.

    2012-01-01


    Background
    Elevated blood pressure is a major risk factor for cardiovascular diseases. Diet and lifestyle have a substantial impact on blood pressure, but the role of protein intake is not yet clear. This thesis focuses on total dietary protein, types of protein (i.e. plant and

  14. Real-time measurement of blood pressure with Nexfin in a patient with thalidomide-related phocomelia.

    Science.gov (United States)

    Earle, Rosie; Vaghadia, Himat; Shanahan, Enda; Tang, Raymond; Sawka, Andrew

    2016-11-01

    We report the novel application of photoplethysmographic technology with the Nexfin HD monitor for real-time measurement of blood pressure (BP) in a patient with tetraamelia. The patient was a 58-year-old man with tetraamelia secondary to thalidomide exposure in utero, who presented for surgical excision of a maxillary schwannoma. Because difficulty of cuff use on rudimentary limbs and failure to gain invasive arterial access due to abnormalities of limb vasculature, this population is known to pose some unique challenges for BP measurement. Nexfin may offer an alternative noninvasive method to detect BP in patients with phocomelia during the perioperative period. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Lack of association between systolic blood pressure and blood viscosity in normotensive healthy subjects.

    Science.gov (United States)

    Irace, Concetta; Carallo, Claudio; Scavelli, Faustina; Loprete, Antonio; Merante, Valentina; Gnasso, Agostino

    2012-01-01

    A direct relationship between blood pressure and viscosity has frequently been reported, although clear data are not available. To better understand the relationship between these two variables, we evaluated blood viscosity and blood pressure in a group of healthy subjects without cardiovascular risk factors. Healthy subjects were selected from participants in a campaign of prevention of cardiovascular disease (n = 103). They underwent blood sampling for measurement of plasma and blood viscosity, haematocrit, blood lipids and glucose. The quantity and distribution of body fat was assessed by body mass index and waist/hip ratio, respectively. Systolic blood pressure (SBP) correlated significantly with age (r = 0.222) and waist/hip ratio (r = 0.374). Diastolic blood pressure (DBP) correlated significantly with waist/hip ratio (r = 0.216), haematocrit (r = 0.333) and blood viscosity (r = 0.258). Multiple linear regression analyses demonstrated that the only variable significantly associated with SBP was age, while haematocrit was the only variable significantly associated with DBP. Blood viscosity was closely related to waist/hip ratio. These findings show that SBP, in healthy subjects, is not influenced by haematocrit and blood viscosity. In contrast, DBP is related to the values of haematocrit. Among classical cardiovascular risk factors, waist/hip ratio is closely related to blood viscosity.

  16. Associations between bacterial infections and blood pressure in pregnancy.

    Science.gov (United States)

    Petry, Clive J; Ong, Ken K; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2017-10-01

    To test the hypothesis that bacterial infections in pregnancy are related to maternal blood pressure. Bacterial infection was assessed using antibiotic usage as a surrogate and its association with blood pressure in pregnancy tested in the Cambridge Baby Growth Study. Antibiotic usage in pregnancy was self-reported in questionnaires. Blood pressure measurements at four time points in pregnancy were collected from the hospital notes of 622 women. Using all the available blood pressure readings (adjusted for weeks gestation) antibiotic usage was associated with a higher mean arterial blood pressure across pregnancy: antibiotics used 85(84, 87)mmHg vs. no antibiotics used 83 (83, 84) mmHg (β=2.3 (0.6, 4.0) mmHg, p=9.6×10 -3 , from 621 individuals). Further analysis revealed that antibiotic usage was associated with diastolic (β=2.3 (0.6, 4.0) mmHg; p=7.0×10 -3 ) more than systolic blood pressure (β=1.4(-0.9, 3.7)mmHg; p=0.2). The effect size associated with antibiotic usage appeared to rise slightly after the first trimester. Bacterial infection in pregnancy, as assessed by self-reported antibiotic usage, is associated with small rises in blood pressure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  17. 21 CFR 870.1110 - Blood pressure computer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... computer. (a) Identification. A blood pressure computer is a device that accepts the electrical signal from...

  18. Blood pressure in Afghan male immigrants to Denmark

    DEFF Research Database (Denmark)

    Asmar, Ali; Bülow, Jens; Simonsen, Lene

    2013-01-01

    PURPOSE: Immigration from a Third-World society to a Western society can be associated with higher blood pressure and salt sensitivity. We therefore tested whether immigrants from Afghanistan to Denmark compared with non-immigrant Danes exhibit a (i) higher 24-h ambulatory blood pressure (24-h ABP...... immigrants to Denmark exhibit a lower 24-h ABP than Danes. In young Afghans, PRA is less sensitive to changes in salt intake, while PNA is higher and may reflect their lower systolic blood pressure and/or arterial pulse pressure. Whether these hormonal differences can explain the lower 24-h ABP in Afghans...

  19. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  20. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  1. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  2. A Novel Neural Network Model for Blood Pressure Estimation Using Photoplethesmography without Electrocardiogram

    Directory of Open Access Journals (Sweden)

    Ludi Wang

    2018-01-01

    Full Text Available The prevention, evaluation, and treatment of hypertension have attracted increasing attention in recent years. As photoplethysmography (PPG technology has been widely applied to wearable sensors, the noninvasive estimation of blood pressure (BP using the PPG method has received considerable interest. In this paper, a method for estimating systolic and diastolic BP based only on a PPG signal is developed. The multitaper method (MTM is used for feature extraction, and an artificial neural network (ANN is used for estimation. Compared with previous approaches, the proposed method obtains better accuracy; the mean absolute error is 4.02 ± 2.79 mmHg for systolic BP and 2.27 ± 1.82 mmHg for diastolic BP.

  3. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

    Science.gov (United States)

    Lanier, Gregg M; Orlanes, Khristine; Hayashi, Yacki; Murphy, Jennifer; Flannery, Margaret; Te-Frey, Rosie; Uriel, Nir; Yuzefpolskaya, Melana; Mancini, Donna M; Naka, Yoshifumi; Takayama, Hiroo; Jorde, Ulrich P; Demmer, Ryan T; Colombo, Paolo C

    2013-09-01

    Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.

  4. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  5. Allergic rhinitis and arterial blood pressure: a population-based study.

    Science.gov (United States)

    Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S

    2018-05-01

    To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.

  6. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  7. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  8. High blood pressure in acute ischemic stroke and clinical outcome.

    Science.gov (United States)

    Manabe, Yasuhiro; Kono, Syoichiro; Tanaka, Tomotaka; Narai, Hisashi; Omori, Nobuhiko

    2009-11-16

    This study aimed to evaluate the prognostic value of acute phase blood pressure in patients with acute ischemic stroke by determining whether or not it contributes to clinical outcome. We studied 515 consecutive patients admitted within the first 48 hours after the onset of ischemic strokes, employing systolic and diastolic blood pressure measurements recorded within 36 hours after admission. High blood pressure was defined when the mean of at least 2 blood pressure measurements was ≥200 mmHg systolic and/or ≥110 mmHg diastolic at 6 to 24 hours after admission or ≥180 mmHg systolic and/or ≥105 mmHg diastolic at 24 to 36 hours after admission. The high blood pressure group was found to include 16% of the patients. Age, sex, diabetes mellitus, hypercholesterolemia, atrial fibrillation, ischemic heart disease, stroke history, carotid artery stenosis, leukoaraiosis, NIH Stroke Scale (NIHSS) on admission and mortality were not significantly correlated with either the high blood pressure or non-high blood pressure group. High blood pressure on admission was significantly associated with a past history of hypertension, kidney disease, the modified Rankin Scale (mRS) on discharge and the length of stay. On logistic regression analysis, with no previous history of hypertension, diabetes mellitus, atrial fibrillation, and kidney disease were independent risk factors associated with the presence of high blood pressure [odds ratio (OR), 1.85 (95% confidence interval (CI): 1.06-3.22), 1.89 (95% CI: 1.11-3.22), and 3.31 (95% CI: 1.36-8.04), respectively]. Multi-organ injury may be presented in acute stroke patients with high blood pressure. Patients with high blood pressure had a poor functional outcome after acute ischemic stroke.

  9. Ambulatory blood pressure and urinary albumin excretion in clinically healthy subjects

    DEFF Research Database (Denmark)

    Clausen, Peter Vilhelm; Jensen, J S; Borch-Johnsen, K

    1998-01-01

    UAER. Because 24-hour ambulatory blood pressure is a superior predictor of hypertensive target organ involvement, we aimed to investigate blood pressure profile in clinically healthy subjects with elevated UAER. Ambulatory blood pressure monitoring was performed with a portable recorder in 27 subjects...... loss of albumin could not be solely related to the higher blood pressure. In conclusion, apparently healthy subjects with elevated UAER had slightly but significantly higher 24-hour systolic and diastolic blood pressure levels in addition to increased blood pressure loads but normal circadian variation...

  10. High blood pressure - what to ask your doctor

    Science.gov (United States)

    What to ask your doctor about high blood pressure; Hypertension - what to ask your doctor ... problems? What medicines am I taking to treat high blood pressure? Do they have any side effects? What should ...

  11. Twenty-Four Hour Non-Invasive Ambulatory Blood Pressure and Heart Rate Monitoring in Parkinson’s Disease

    Science.gov (United States)

    Stuebner, Eva; Vichayanrat, Ekawat; Low, David A.; Mathias, Christopher J.; Isenmann, Stefan; Haensch, Carl-Albrecht

    2013-01-01

    Non-motor symptoms are now commonly recognized in Parkinson’s disease (PD) and can include dysautonomia. Impairment of cardiovascular autonomic function can occur at any stage of PD but is typically prevalent in advanced stages or related to (anti-Parkinsonian) drugs and can result in atypical blood pressure (BP) readings and related symptoms such as orthostatic hypotension (OH) and supine hypertension. OH is usually diagnosed with a head-up-tilt test (HUT) or an (active) standing test (also known as Schellong test) in the laboratory, but 24 h ambulatory blood pressure monitoring (ABPM) in a home setting may have several advantages, such as providing an overview of symptoms in daily life alongside pathophysiology as well as assessment of treatment interventions. This, however, is only possible if ABPM is administrated correctly and an autonomic protocol (including a diary) is followed which will be discussed in this review. A 24-h ABPM does not only allow the detection of OH, if it is present, but also the assessment of cardiovascular autonomic dysfunction during and after various daily stimuli, such as postprandial and alcohol dependent hypotension, as well as exercise and drug induced hypotension. Furthermore, information about the circadian rhythm of BP and heart rate (HR) can be obtained and establish whether or not a patient has a fall of BP at night (i.e., “dipper” vs. non-“dipper”). The information about nocturnal BP may also allow the investigation or detection of disorders such as sleep dysfunction, nocturnal movement disorders, and obstructive sleep apnea, which are common in PD. Additionally, a 24-h ABPM should be conducted to examine the effectiveness of OH therapy. This review will outline the methodology of 24 h ABPM in PD, summarize findings of such studies in PD, and briefly consider common daily stimuli that might affect 24 h ABPM. PMID:23720648

  12. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  13. Changes You Can Make to Manage High Blood Pressure

    Science.gov (United States)

    ... about Bayer Consumer Health. HBP Resources Risk Calculator Animation Library Track Your Blood Pressure: Print (PDF) | Online ... Pressure Tracker Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  14. Blood Pressure Medications: Can They Raise My Triglycerides?

    Science.gov (United States)

    ... medications: Can they raise my triglycerides? Can some blood pressure medications cause an increase in triglycerides? Answers from Sheldon G. Sheps, M.D. Yes, some blood pressure medications can affect triglyceride and cholesterol levels. Hydrochlorothiazide ...

  15. Blood pressure pattern of adolescent offsprings of hypertensive ...

    African Journals Online (AJOL)

    Blood pressure pattern of adolescent offsprings of hypertensive fathers in Lagos ... in adults which emphasizes the need to track blood pressure in children. ... are hypertensive while among adolescents with normotensive parents, 11.0% for ...

  16. [Blood pressure targets : The lower the better does not suit all].

    Science.gov (United States)

    Hoffmann, U

    2018-04-01

    The systolic blood pressure intervention trial (SPRINT) published in 2015 has opened up new discussions on whether a lower blood pressure target as recommended by the current guidelines would be better for some patient groups. To review patient groups in which lower blood pressure targets would not be better. The results of SPRINT, its post-hoc and subgroup analyses, other studies and newer studies, as well as metaanalyses on the topic of blood pressure targets are reviewed and discussed. Studies with patients excluded from the SPRINT study were also analysed. The current international guidelines and recommendations of the Deutsche Hochdruckliga e. V. DHL® are included. Blood pressure monitoring methods differed considerably in the previously published studies. The low blood pressure value in SPRINT was mainly achieved due to the unusual method of blood pressure monitoring used and, as such, cannot be compared with blood pressure values in other studies. Based on current evidence, "the lower the better" should not be recommended in the following patient groups: older patients, in particular infirm older patients, patients with diabetes, patients without coronary heart disease or with low cardiovascular risk. When determining a blood pressure target, the method of blood pressure monitoring should be defined. A lower blood pressure target has been shown to be better in some well defined patient groups. However, adverse events due to antihypertensive medications should always be taken into account. Given the multiple exclusion criteria in trials and the results of many studies, "new" lower blood pressure targets could not be recommended in a large population of patients.

  17. Noninvasive optoacoustic system for rapid diagnostics and management of circulatory shock

    Science.gov (United States)

    Esenaliev, Rinat O.; Petrov, Irene Y.; Petrov, Yuriy; Kinsky, Michael; Prough, Donald S.

    2012-02-01

    Circulatory shock is lethal, if not promptly diagnosed and effectively treated. Typically, circulatory shock resuscitation is guided by blood pressure, heart rate, and mental status, which have poor predictive value. In patients, in whom early goaldirected therapy was applied using central venous oxygenation measurement, a substantial reduction of mortality was reported (from 46.5% to 30%). However, central venous catheterization is invasive, time-consuming and often results in complications. We proposed to use the optoacoustic technique for noninvasive, rapid assessment of central venous oxygenation. In our previous works we demonstrated that the optoacoustic technique can provide measurement of blood oxygenation in veins and arteries due to high contrast and high resolution. In this work we developed a novel optoacoustic system for noninvasive, automatic, real-time, and continuous measurement of central venous oxygenation. We performed pilot clinical tests of the system in human subjects with different oxygenation in the internal jugular vein and subclavian vein. A novel optoacoustic interface incorporating highly-sensitive optoacoustic probes and standard ultrasound imaging probes were developed and built for the study. Ultrasound imaging systems Vivid i and hand-held Vscan (GE Healthcare) as well as Site-Rite 5 (C.R. Bard) were used in the study. We developed a special algorithm for oxygenation monitoring with minimal influence of overlying tissue. The data demonstrate that the system provides precise measurement of venous oxygenation continuously and in real time. Both current value of the venous oxygenation and trend (in absolute values and for specified time intervals) are displayed in the system. The data indicate that: 1) the optoacoustic system developed by our group is capable of noninvasive measurement of blood oxygenation in specific veins; 2) clinical ultrasound imaging systems can facilitate optoacoustic probing of specific blood vessels; 3) the

  18. Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia.

    Science.gov (United States)

    Proença, Martin; Braun, Fabian; Solà, Josep; Adler, Andy; Lemay, Mathieu; Thiran, Jean-Philippe; Rimoldi, Stefano F

    2016-06-01

    Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.

  19. Does chocolate reduce blood pressure? A meta-analysis

    Directory of Open Access Journals (Sweden)

    Ried Karin

    2010-06-01

    Full Text Available Abstract Background Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. Methods We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive. Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P Results Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change ± SE: SBP: -3.2 ± 1.9 mmHg, P = 0.001; DBP: -2.0 ± 1.3 mmHg, P = 0.003. However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 ± 3.0 mmHg; P = 0.0009; DBP: -2.7 ± 2.2 mm Hg, P = 0.01, while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 ± 2.3 mmHg, P = 0.17; DBP: -1.3 ± 1.6 mmHg, P = 0.12. Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30

  20. Blood pressure standards for Saudi children and adolescents

    International Nuclear Information System (INIS)

    AlSalloum, Abdullah A.; El Mouzan, Mohammad I.; AlHerbish, Abdullah S.; AlOmar, Ahmad A.; Qurashi, Mansour M.

    2009-01-01

    Blood pressure levels may vary in children because of genetic, ethnic and socioeconomic factors. To date, there have been no large national studies in Saudi Arabia on blood pressure in children. Therefore, we sought to establish representative blood pressure reference centiles for Saudi Arabian children and adolescents. We selected a sample of children and adolescents aged from birth to 18 years by multi-stage probability sampling of the Saudi population. The selected sample represented Saudi children from the whole country. Data were collected through a house-to-house survey of all selected households in all 13 regions in the country. Data were analyzed to study the distribution pattern of systolic (SBP) and diastolic blood pressure (DBP) and to develop reference values. The 90th percentile of SBP and DBP values for each age were compared with values from a Turkish and an American study. A total of 16 226 Saudi children and adolescents from birth to 18 years were studied. Blood pressure rose steadily with age in both boys and girls. The average annual increase in SBP was 1.66 mm Hg for boys and1.44 mm Hg for girls. The average annual increase in DBP was 0.83 mm Hg for boys and 0.77 mm Hg for girls. DBP rose sharply in boys at the age of 18 years. Values for the 90th percentile of both SBP and DBP varied in Saudi children from their Turkish and American counterparts for all age groups. Blood pressure values in this study differed from those from other studies in developing countries and in the United States, indicating that comparison across studies is difficult and from that every population should use their own normal standards to define measured blood pressure levels in children. (author)

  1. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  2. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    lifting and supporting weights) and have an important influence on blood pressure, it is essential to evaluate blood pressure response to iso- metric effort. This test can reveal high blood pressure that might otherwise not be detected. Only a few ...

  3. Different systolic blood pressure targets for people with history of stroke or transient ischaemic attack: PAST-BP (Prevention After Stroke—Blood Pressure) randomised controlled trial

    Science.gov (United States)

    McManus, Richard J; Roalfe, Andrea; Fletcher, Kate; Taylor, Clare J; Martin, Una; Virdee, Satnam; Greenfield, Sheila; Hobbs, F D Richard

    2016-01-01

    Objective To assess whether using intensive blood pressure targets leads to lower blood pressure in a community population of people with prevalent cerebrovascular disease. Design Open label randomised controlled trial. Setting 99 general practices in England, with participants recruited in 2009-11. Participants People with a history of stroke or transient ischaemic attack whose systolic blood pressure was 125 mm Hg or above. Interventions Intensive systolic blood pressure target (different target, patients in both arms were actively managed in the same way with regular reviews by the primary care team. Main outcome measure Change in systolic blood pressure between baseline and 12 months. Results 529 patients (mean age 72) were enrolled, 266 to the intensive target arm and 263 to the standard target arm, of whom 379 were included in the primary analysis (182 (68%) intensive arm; 197 (75%) standard arm). 84 patients withdrew from the study during the follow-up period (52 intensive arm; 32 standard arm). Mean systolic blood pressure dropped by 16.1 mm Hg to 127.4 mm Hg in the intensive target arm and by 12.8 mm Hg to 129.4 mm Hg in the standard arm (difference between groups 2.9 (95% confidence interval 0.2 to 5.7) mm Hg; P=0.03). Conclusions Aiming for target below 130 mm Hg rather than 140 mm Hg for systolic blood pressure in people with cerebrovascular disease in primary care led to a small additional reduction in blood pressure. Active management of systolic blood pressure in this population using a blood pressure. Trial registration Current Controlled Trials ISRCTN29062286. PMID:26919870

  4. Acute effects of consumption of energy drinks on intraocular pressure and blood pressure

    Directory of Open Access Journals (Sweden)

    Ilechie AA

    2011-04-01

    Full Text Available A Alex Ilechie, Sandra TettehDepartment of Optometry, University of Cape Coast, GhanaBackground: Energy drinks contain a wide variety of ingredients including caffeine, for which there have been conflicting reports regarding its effects on intraocular pressure (IOP and blood pressure. The aim of this study was to investigate the acute effects of an energy drink (Red Bull® on the IOP and blood pressure of healthy young adults.Methods: Thirty healthy university students of either gender, aged 18–30 (mean 23.20 ± 2.81 years were randomly selected to participate in this study. The subjects were randomly divided into two groups (experimental and control and were asked to abstain from caffeine for 48 hours prior to and during the study. Baseline IOP and blood pressure were measured. The experimental group (n = 15 consumed one can of the energy drink (containing 85 mg of caffeine in 250 mL and measurements were repeated at 30, 60, and 90 minutes, while the control group drank 250 mL of water and were tested over the same time period.Results: When compared with baseline, a significant decrease (P < 0.05 in mean IOP at 60 and 90 minutes was observed in the experimental group. There was no corresponding change in systolic or diastolic blood pressure.Conclusion: Our results suggest that energy drinks (ie, Red Bull produce a significant reduction in IOP but have no effect on blood pressure. These findings may be interpreted as reflecting the effect of the combination of caffeine and taurine in the Red Bull energy drink. This effect may result from the known hypotensive effect of taurine, and warrants further study.Keywords: acute effect, intraocular pressure, blood pressure, glaucoma, caffeine, taurine

  5. The Role of Central Blood Pressure Monitoring in the Management of Hypertension.

    Science.gov (United States)

    Ochoa, Adrian; Patarroyo-Aponte, Gabriel; Rahman, Mahboob

    2018-04-19

    Central blood pressure is a novel predictor of cardiovascular risk that can be measured in the clinical setting using currently available technology. This paper will review current available methods of central blood pressure monitoring as well as its impact in cardiac and renal disease. Both aortic and carotid systolic blood pressure are independently associated with cardiovascular mortality and serious cardiac events. Furthermore, studies show that systolic aortic blood pressure has been shown to be superior predictor of cardiovascular as compared to brachial blood pressure. Inhibitors of the renin angiotensin axis may have a beneficial effect on central blood pressure; however, long term studies evaluating the impact of lowering central blood pressure on clinical outcomes are lacking. Central blood pressure is a good predictor of cardiovascular risk. As more studies emerge demonstrating the value of central blood pressure as a therapeutic target, it is possible that targeting central blood pressure may become an important part of the armamentarium to lower cardiovascular risk.

  6. Blood pressure and pain sensitivity in children and adolescents.

    Science.gov (United States)

    Drouin, Sammantha; McGrath, Jennifer J

    2013-06-01

    Elevated blood pressure is associated with diminished pain sensitivity. While this finding is well established in adults, it is less clear when the relation between blood pressure and pain sensitivity emerges across the life course. Evidence suggests this phenomenon may exist during childhood. Children (N = 309; 56% boys) aged 10-15 years and their parents participated. Blood pressure readings were taken during a resting baseline. Maximum pain intensity was rated using a visual analogue scale (rated 0-10) in response to a finger prick pain induction. Parent-measured resting blood pressure was inversely associated with boys' pain ratings only. Cross-sectionally, lower pain ratings were related to higher SBP, univariately. Longitudinally, pain ratings predicted higher DBP, even after controlling for covariates. Determining when and how the relation between blood pressure and pain sensitivity emerges may elucidate the pathophysiology of hypertension. Copyright © 2013 Society for Psychophysiological Research.

  7. Teaming Up Against High Blood Pressure PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-09-04

    Nearly one-third of American adults have high blood pressure, and more than half of them don’t have it under control. Simply seeing a doctor and taking medications isn’t enough for many people who have high blood pressure. A team-based approach by patients, health care systems, and health care providers is one of the best ways to treat uncontrolled high blood pressure.  Created: 9/4/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 9/4/2012.

  8. Sleep Deprivation: A Cause of High Blood Pressure?

    Science.gov (United States)

    ... it true that sleep deprivation can cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Possibly. It's thought that ... hours a night could be linked to increased blood pressure. People who sleep five hours or less a ...

  9. How Potassium Can Help Control High Blood Pressure

    Science.gov (United States)

    ... Aneurysm More How Potassium Can Help Control High Blood Pressure Updated:Jan 29,2018 Understanding the heart-healthy ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  10. How High Blood Pressure Can Lead to Stroke

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More How High Blood Pressure Can Lead to Stroke Updated:Jan 29,2018 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  11. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording

    NARCIS (Netherlands)

    Imholz, B. P.; Langewouters, G. J.; van Montfrans, G. A.; Parati, G.; van Goudoever, J.; Wesseling, K. H.; Wieling, W.; Mancia, G.

    1993-01-01

    We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record

  12. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    Energy Technology Data Exchange (ETDEWEB)

    Garner, Rochelle E., E-mail: rochelle.garner@canada.ca [Health Analysis Division, Statistics Canada, Ottawa, Ontario (Canada); Levallois, Patrick [Direction de la santé environnementale et de la toxicologie, Institut National de Santé Publique du Québec, Québec City, Québec (Canada); Axe santé des populations et pratiques optimales en santé, Centre de Recherche du CHU de Québec-Université Laval, Québec City, Québec (Canada)

    2017-05-15

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure

  13. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    International Nuclear Information System (INIS)

    Garner, Rochelle E.; Levallois, Patrick

    2017-01-01

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure

  14. The effect of ventricular assist devices on cerebral blood flow and blood pressure fractality

    International Nuclear Information System (INIS)

    Bellapart, Judith; Fraser, John F; Chan, Gregory S H; Tzeng, Yu-Chieh; Ainslie, Philip N; Dunster, Kimble R; Barnett, Adrian G; Boots, Rob

    2011-01-01

    Biological signals often exhibit self-similar or fractal scaling characteristics which may reflect intrinsic adaptability to their underlying physiological system. This study analysed fractal dynamics of cerebral blood flow in patients supported with ventricular assist devices (VAD) to ascertain if sustained modifications of blood pressure waveform affect cerebral blood flow fractality. Simultaneous recordings of arterial blood pressure and cerebral blood flow velocity using transcranial Doppler were obtained from five cardiogenic shock patients supported by VAD, five matched control patients and five healthy subjects. Computation of a fractal scaling exponent (α) at the low-frequency time scale by detrended fluctuation analysis showed that cerebral blood flow velocity exhibited 1/f fractal scaling in both patient groups (α = 0.95 ± 0.09 and 0.97 ± 0.12, respectively) as well as in the healthy subjects (α = 0.86 ± 0.07). In contrast, fluctuation in blood pressure was similar to non-fractal white noise in both patient groups (α = 0.53 ± 0.11 and 0.52 ± 0.09, respectively) but exhibited 1/f scaling in the healthy subjects (α = 0.87 ± 0.04, P < 0.05 compared with the patient groups). The preservation of fractality in cerebral blood flow of VAD patients suggests that normal cardiac pulsation and central perfusion pressure changes are not the integral sources of cerebral blood flow fractality and that intrinsic vascular properties such as cerebral autoregulation may be involved. However, there is a clear difference in the fractal scaling properties of arterial blood pressure between the cardiogenic shock patients and the healthy subjects

  15. Blood pressure control among type 2 diabetics

    International Nuclear Information System (INIS)

    Al-Shehri, Ahmed M.

    2008-01-01

    Objective was to assess blood pressure BP control in patients with diabetes mellitus type 2 DM type treated in primary health care. A cross-sectional study was conducted in primary health care at King Fahd Military Complex Hospital in Dhahran, Kingdom of Saudi Arabia, between August 2003 and February 2004, to assess blood control in type 2 diabetics. A sample of 403 medical records of type 2 diabetic patients was selected using systematic random sampling after ordering the medical record numbers. The data were collected through the pre-coded checklist. Hypertension was found in 57.8% of diabetic patients with no statistically significant difference between males and females. The mean age of diabetic patients was significantly highly in hypertensive than non-hypertensive p=0.001. The mean duration of hypertension was significantly higher in females p=0.02. There were only 14.2% of hypertensive diabetic patients in whom blood pressure was controlled. Poor control was significantly associated with obesity and a high rate of complications. Blood pressure control correlated positively and significantly with the age of patients and negatively with duration of diabetes and hypertension. The most commonly prescribed antihypertensive were angiotensin converting enzyme inhibitors in 29.3%, followed by angiotensin receptors blockers in 24.1%, and the least prescribed drug was thiazide diuretic. Blood pressure in diabetic patients needs to be given particular attention from all health care professionals, especially primary care family physicians, who should follow the new guideline for better control of blood pressure, and fewer complications. Patient's awareness should be increased, through continuous health education with different modalities. (author)

  16. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined.

  17. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined

  18. The effects of endurance and resistance training on blood pressure.

    Science.gov (United States)

    Schwartz, R S; Hirth, V A

    1995-10-01

    There now exists substantial clinical data supporting a blood pressure lowering effect of endurance training. Though the effect is modest (5-10 mmHg), epidemiologic studies indicate the possibility of protection against the development of hypertension and also indicate significantly reduced cardiovascular mortality and increased longevity associated with chronic endurance exercise. The data for blood pressure lowering effects of resistive training are much less compelling, and this area requires additional investigation. However, it appears that resistance training is not associated with chronic elevations in blood pressure. Future studies need to focus on: 1) the relative efficacy of low-, moderate- and high-intensity training on lowering blood pressure; 2) the effect of training on ambulatory blood pressure; 3) targeting of at risk and high responding populations; and 4) the importance of insulinemia, SNS tone and central adiposity in the mechanism of any blood pressure lowering effect of training.

  19. Dysglycemia induces abnormal circadian blood pressure variability

    Directory of Open Access Journals (Sweden)

    Kumarasamy Sivarajan

    2011-11-01

    Full Text Available Abstract Background Prediabetes (PreDM in asymptomatic adults is associated with abnormal circadian blood pressure variability (abnormal CBPV. Hypothesis Systemic inflammation and glycemia influence circadian blood pressure variability. Methods Dahl salt-sensitive (S rats (n = 19 after weaning were fed either an American (AD or a standard (SD diet. The AD (high-glycemic-index, high-fat simulated customary human diet, provided daily overabundant calories which over time lead to body weight gain. The SD (low-glycemic-index, low-fat mirrored desirable balanced human diet for maintaining body weight. Body weight and serum concentrations for fasting glucose (FG, adipokines (leptin and adiponectin, and proinflammatory cytokines [monocyte chemoattractant protein-1 (MCP-1 and tumor necrosis factor-α (TNF-α] were measured. Rats were surgically implanted with C40 transmitters and blood pressure (BP-both systolic; SBP and diastolic; DBP and heart rate (HR were recorded by telemetry every 5 minutes during both sleep (day and active (night periods. Pulse pressure (PP was calculated (PP = SBP-DBP. Results [mean(SEM]: The AD fed group displayed significant increase in body weight (after 90 days; p Conclusion These data validate our stated hypothesis that systemic inflammation and glycemia influence circadian blood pressure variability. This study, for the first time, demonstrates a cause and effect relationship between caloric excess, enhanced systemic inflammation, dysglycemia, loss of blood pressure control and abnormal CBPV. Our results provide the fundamental basis for examining the relationship between dysglycemia and perturbation of the underlying mechanisms (adipose tissue dysfunction induced local and systemic inflammation, insulin resistance and alteration of adipose tissue precursors for the renin-aldosterone-angiotensin system which generate abnormal CBPV.

  20. Blood pressure and blood flow variation during postural change from sitting to standing: model development and validation

    DEFF Research Database (Denmark)

    Olufsen, M.S.; Ottesen, Johnny T.; Tran, H.T.

    2005-01-01

    Short-term cardiovascular responses to postural change from sitting to standing involve complex interactions between the autonomic nervous system, which regulates blood pressure, and cerebral autoregulation, which maintains cerebral perfusion. We present a mathematical model that can predict...... dynamic changes in beat-to-beat arterial blood pressure and middle cerebral artery blood flow velocity during postural change from sitting to standing. Our cardiovascular model utilizes 11 compartments to describe blood pressure, blood flow, compliance, and resistance in the heart and systemic circulation....... To include dynamics due to the pulsatile nature of blood pressure and blood flow, resistances in the large systemic arteries are modeled using nonlinear functions of pressure. A physiologically based submodel is used to describe effects of gravity on venous blood pooling during postural change. Two types...

  1. Non-invasive method to detect the changes of glucose concentration in whole blood using photometric technique.

    Science.gov (United States)

    Rajan, Shiny Amala Priya; Towe, Bruce C

    2014-01-01

    A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.

  2. Analysis of end-systolic pressure-volume relation by gated radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Horoki; Katsume, Hiroshi; Ijichi, Hamao; Miyanaga, Hajime

    1982-01-01

    Left ventricular end-systolic pressure-volume relation has been proved experimentally to b e an useful index of left ventricular contractility relatively independent of preload or afterload. But less clinical application has been reported because of its invasive nature, and we evaluated this relationship non-invasively using gated radionuclide angiocardiography as volume determination and cuff sphyngomanometer in the arm as pressure measurement. Gated equilibrium blood pool scintigrams were obtained at rest and during intravenous infusion of angiotensin or nitrate. Ventricular volumes were derived from ventricular activity and peripheral blood volume and activity. The peak systolic pressure (PSP) by cuff method to end-systolic volume index (ESVI) relations showed good linearity (r gt .930 in 84% of consecutive 50 cases) and were gentler in the groups with more impaired left ventricular function. Emax was related exponentially to ejection fraction (EF) and hyperbolically to end-diastolic volume index. The dead volume (VoI) was unfixed and fell into positive or negative value, and was not related to EF under control condition. PSP/ESVI in each loading condition was less variable with the alteration of blood pressure than EF. The linear relation was found between PSP/ESVI under control condition and Emax (PSP/ESVI = 0.651.Emax + 0.958, r = 0.841, p lt .001). Thus in measuring ventricular volume, gated radionuclide angiocardiography is a non-invasive method less affected by the geometry of the left ventricle. Non-invasive determination of end-systolic pressure-volume relation using the volume by radionuclide and the blood pressure by cuff method is clinically useful in the assessment of left ventricular contractility. (author)

  3. Self-monitored blood pressure: a role in clinical practice?

    Science.gov (United States)

    Padfield, Paul L

    2002-02-01

    Electronic self-monitoring of blood pressure is increasing in popularity and most international guidelines on the management of hypertension approve cautious use of the technique in the assessment of potentially hypertensive individuals. A recent editorial in the Archives of Internal Medicine suggested that it was "appropriate to encourage the widespread use of self recorded BP as an important adjunct to the clinical care of the patient with hypertension". Such a statement is based on increasing evidence that self-monitoring of blood pressure gives similar information to daytime ambulatory blood pressure -- a now well-established technology in the management of hypertension. Suggested strategies for the use of self-monitoring of blood pressure include monitoring in individuals whose clinical risk status is low enough that they need not necessarily be given medical therapy simply on the basis of a clinic pressure (i.e. at a 10 year risk of cardiovascular disease below 20%). The threshold for defining 'normotension/hypertension' is now regarded as being broadly similar for ABPM and SBPM and is set at 135/85 mmHg. In a recent meta-analysis of all available studies the average difference between these techniques, using the same patients, is -1.7/1.2 mmHg. There is some evidence that careful use of self-monitoring may improve blood pressure control in patients who are otherwise resistant to care. Self-monitoring of blood pressure has now been shown in at least one major prospective study to predict outcome better than clinic pressures and in that setting it now has equivalence to the use of ABPM. There remain issues regarding the availability of validated devices, the quality of training of patients in their use and the possibility that inaccurate recording might occur, either deliberately or by accident. Self-monitoring of blood pressure may well not give the same readings as carefully measured blood pressure by research nurses but its use is clearly superior to

  4. Blood pressure control among patients with hypertension and newly diagnosed diabetes.

    Science.gov (United States)

    Choma, N N; Griffin, M R; Kaltenbach, L A; Greevy, R A; Roumie, C L

    2012-09-01

    To determine the proportion of patients who achieved blood pressure control during the 2 years following new diabetes diagnosis. A retrospective cohort of veterans ≥ 18 years with hypertension who initiated a diabetes medication from 2000 to 2007 in the Veterans Administration Mid-South Network was assembled. Blood pressure control at diabetes treatment initiation (baseline) was compared with blood pressure control 6, 12, 18 and 24 months later. The Veterans Affairs and American Diabetes Association definitions of control, ≤ 140/90 and ≤ 130/80 mmHg, respectively, were primary and secondary outcomes. At baseline, 59.5% of 16,182 patients had controlled blood pressure according to the Veterans Affairs guideline (31.5% using American Diabetes Association definition). Six months following initiation of diabetes treatment, 65.7% had their blood pressure controlled (P < 0.001). Blood pressure control was sustained but not further improved between 6 months and 2 years, with 66.5% controlled at 2 years following baseline. Higher initial systolic blood pressure, black race and hospitalization in the previous year were associated with higher likelihood of uncontrolled blood pressure at 6 months; whereas baseline cardiovascular disease, baseline dementia and later year of cohort entry were associated with lower likelihood of uncontrolled blood pressure. We found an increase in blood pressure control in the 6 months following initiation of diabetes treatment. However, overall blood pressure control remained suboptimal and with no further improvement over the next 18 months. Published 2011. This article is a US Government work and is in the public domain in the USA.

  5. Does chocolate reduce blood pressure? A meta-analysis.

    Science.gov (United States)

    Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P

    2010-06-28

    Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment groups, and interventions ran for 2 to 18 weeks. Meta-regression analysis found study design and type of control to be borderline significant but possibly indirect predictors

  6. Blood pressure and control of cardiovascular risk

    Directory of Open Access Journals (Sweden)

    Judith A Whitworth

    2005-10-01

    Full Text Available Judith A WhitworthJohn Curtin School of Medical Research, Australian National University, Canberra, ACT, AustraliaAbstract: Two key early 20th century notions, the first the primacy of diastolic pressure in determining risk, and the second that hypertension is a discrete disorder, have proved to be incorrect. We now recognize the primacy of systolic pressure as a risk factor for cardiovascular disease and that hypertension is an arbitrary definition. In the early 21st century, we are moving away from a dichotomous approach to risk classification, and away from notions of hypertension and normotension towards an appreciation that blood pressure-related risk is continuous. In parallel, there has been a paradigm shift from a single risk factor approach to comprehensive cardiovascular disease risk prevention. Accordingly, prevention of cardiovascular disease requires a focus on lowering of blood pressure and modification of associated risk factors rather than simply treatment of hypertension. This emphasis is reflected in the World Health Organization (WHO – International Society of Hypertension (ISH 2003 statement on management of hypertension.Keywords: blood pressure, hypertension, cardiovascular risk, treatment

  7. Improvement of Diurnal Blood Pressure Variation by Azilsartan.

    Science.gov (United States)

    Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori

    2018-01-01

    Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers.

  8. Prenatal air pollution exposure and newborn blood pressure

    NARCIS (Netherlands)

    van Rossem, Lenie; Rifas-Shiman, Sheryl L.; Melly, Steven J.; Kloog, Itai; Luttmann-Gibson, Heike; Zanobetti, Antonella; Coull, Brent A.; Schwartz, Joel D.; Mittleman, Murray A.; Oken, Emily; Gillman, Matthew W.; Koutrakis, Petros; Gold, Diane R.

    2015-01-01

    Background: Air pollution exposure has been associated with increased blood pressure in adults. oBjective: We examined associations of antenatal exposure to ambient air pollution with newborn systolic blood pressure (SBP). Methods: We studied 1,131 mother–infant pairs in a Boston, Massachusetts,

  9. Blood pressure and sexual maturity in adolescents: the Heartfelt Study.

    Science.gov (United States)

    Cho, S D; Mueller, W H; Meininger, J C; Liehr, P; Chan, W

    2001-01-01

    This study investigates sexual maturity as a predictor of resting blood pressures independent of other known predictors, in 179 boys and 204 girls 11-16 years of age from the Heartfelt Study. The sample included youth of African (n = 140), Mexican (n = 117), and European and "other" (n = 126) backgrounds. Sexual maturity was assessed during clinical examination of three standard indicators for each sex. Systolic and diastolic blood pressures were higher in children of maturity stages IV and V, compared to stages I-III, in each gender/ethnic group (P maturity for their age group, had significantly higher systolic blood pressures (but not diastolic) than the less advanced in linear models that included height, body mass index (BMI), ethnicity, and age as co-predictors. Diastolic blood pressures were predicted by height in boys and by age and the BMI in girls. This analysis, using a very conservative approach, suggests that sexual maturity provides important and independent information on systolic blood pressure in adolescents. Further investigation of its role in 24-hr blood pressures and in blood pressures taken during physical and emotional stress, is recommended.

  10. Announcement: National High Blood Pressure Education Month - May 2016.

    Science.gov (United States)

    2016-05-27

    May is National High Blood Pressure Education Month. High blood pressure (hypertension) is a major contributor to heart disease and stroke, two leading causes of death in the United States.* High blood pressure affects one third of U.S. adults, or approximately 75 million persons, yet approximately 11 million of these persons are not aware they have hypertension, and approximately 18 million are not being treated (unpublished data) (1,2).

  11. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  12. Gingival crevicular blood: As a non-invasive screening tool for diabetes mellitus in dental clinics

    Directory of Open Access Journals (Sweden)

    Neema Shetty

    2013-01-01

    Full Text Available Background: A high number of patients with periodontitis may have undiagnosed diabetes. Self-monitoring devices provide a simple method for rapid monitoring of the glucose level in the blood by utilizing a blood sample from the finger, but this method requires a needle puncture to obtain blood. It is possible that gingival crevicular blood (GCB from routine periodontal probing may be a source of blood for glucose measurements. Aim: To establish whether GCB can be used as a non-invasive diagnostic aid in screening for diabetes mellitus during routine periodontal examination. Materials and Methods: The study involved 50 diabetics and 50 non-diabetics, with an age range of 26-66 years. Both diabetic and non-diabetic patients had moderate to severe gingivitis with at least one tooth in the maxillary anterior region showing bleeding upon probing. The Gingival Index and Oral Hygiene Index-Simplified were recorded. Blood oozing from the gingival sulcus/pocket following periodontal pocket probing was collected using a capillary tube and transferred to the test stick of a glucose self-monitoring device (Accu-Chek, Roche Diagnostic, Germany in patients with comparable gingival and oral hygiene status. This value was compared with the peripheral fingerstick blood glucose (PFBG value, which was obtained by pricking the finger tip at the same visit. Statistical analysis was performed using Pearson′s correlation coefficient. Result: There was no statistically significant difference between the gingival crevicular blood glucose (GCBG values and the PFBG values in both the diabetic (P = 0.129, NS and the non-diabetic (P = 0.503, NS groups. Karl Pearson′s product-moment correlation coefficient was calculated, which showed a positive correlation between the two measurements in the diabetic (r = 0.943 as well as the non-diabetic (r = 0.926 groups. Conclusion: The results suggest that GCB can be used as a non-invasive diagnostic aid in screening for diabetes

  13. Noninvasive assessment of pulmonary vascular and airway response to physiologic stimuli with high-resolution CT

    International Nuclear Information System (INIS)

    Herold, C.J.; Wetzel, R.C.; Herold, S.M.; Martin, L.; Zerhouni, E.A.; Robotham, J.

    1990-01-01

    This paper reports on reactivity of pulmonary vasculature under various stimuli studied invasively with perfused isolated lung models. We used high- resolution CT (HRCT) to demonstrate noninvasively the effects of hypoxia and volume variation on pulmonary circulation and airways. Five anesthetized and ventilated pigs were examined with HRCT (10 contiguous 2-mm sections through the lower lobes) during varying oxygen tensions and intravascular volume states. Blood pressures, pulmonary artery pressures, blood gas levels, and cardiac indexes (thermodilution) were measured. HRCT scans were digitized, and vessel and airway areas were determined with use of a computer edging process

  14. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  15. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    Science.gov (United States)

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; pmasks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  16. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  17. Goat meat does not cause increased blood pressure.

    Science.gov (United States)

    Sunagawa, Katsunori; Kishi, Tetsuya; Nagai, Ayako; Matsumura, Yuka; Nagamine, Itsuki; Uechi, Shuntoku

    2014-01-01

    While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g) were evenly separated into 4 groups. The control group (CP) was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM) was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS) was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan)/salt group (GY) was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (pgoat meat does not cause increased blood pressure, rather the large amount of salt used in the preparation of goat meat dishes is responsible for the increase in blood pressure.

  18. Take your blood pressure to heart! Screening programme 13-17 October

    CERN Multimedia

    2014-01-01

    The silent health threat, high blood pressure, can only be detected by regular blood pressure tests. In Switzerland, one in four people suffer from high blood pressure without being aware of it.  A screening programme will take place from 13 to 17 October 2014 at the Medical Service Infirmary, Building 57, from 9 a.m. to 12 p.m. and from 1.30 to 4.30 p.m. Blood pressure tests, advice and general information on high blood pressure will be available to everyone working at CERN. Medical Service

  19. Comparison of different models for non-invasive FFR estimation

    Science.gov (United States)

    Mirramezani, Mehran; Shadden, Shawn

    2017-11-01

    Coronary artery disease is a leading cause of death worldwide. Fractional flow reserve (FFR), derived from invasively measuring the pressure drop across a stenosis, is considered the gold standard to diagnose disease severity and need for treatment. Non-invasive estimation of FFR has gained recent attention for its potential to reduce patient risk and procedural cost versus invasive FFR measurement. Non-invasive FFR can be obtained by using image-based computational fluid dynamics to simulate blood flow and pressure in a patient-specific coronary model. However, 3D simulations require extensive effort for model construction and numerical computation, which limits their routine use. In this study we compare (ordered by increasing computational cost/complexity): reduced-order algebraic models of pressure drop across a stenosis; 1D, 2D (multiring) and 3D CFD models; as well as 3D FSI for the computation of FFR in idealized and patient-specific stenosis geometries. We demonstrate the ability of an appropriate reduced order algebraic model to closely predict FFR when compared to FFR from a full 3D simulation. This work was supported by the NIH, Grant No. R01-HL103419.

  20. Admission Blood Pressure of Stroke Patients and Its Relationship to ...

    African Journals Online (AJOL)

    Background: High blood pressure is often said to be associated with poor outcome in stroke. However, there remains some uncertainly about the relationship of blood pressure to mortality in stroke. Objective: This study seeks to determine the influence of admission blood pressure on early mortality of stroke patients at the ...

  1. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    Blood pressure at rest is not predictive of roundthe- clock values. Blood pressure should therefore be measured during effort to evaluate hypertension and its response to treatment. The effect of sustained-release verapamil (240 mg taken once a day) on blood pressure at rest and during isometric effort was therefore ...

  2. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  3. Analytical model for real time, noninvasive estimation of blood glucose level.

    Science.gov (United States)

    Adhyapak, Anoop; Sidley, Matthew; Venkataraman, Jayanti

    2014-01-01

    The paper presents an analytical model to estimate blood glucose level from measurements made non-invasively and in real time by an antenna strapped to a patient's wrist. Some promising success has been shown by the RIT ETA Lab research group that an antenna's resonant frequency can track, in real time, changes in glucose concentration. Based on an in-vitro study of blood samples of diabetic patients, the paper presents a modified Cole-Cole model that incorporates a factor to represent the change in glucose level. A calibration technique using the input impedance technique is discussed and the results show a good estimation as compared to the glucose meter readings. An alternate calibration methodology has been developed that is based on the shift in the antenna resonant frequency using an equivalent circuit model containing a shunt capacitor to represent the shift in resonant frequency with changing glucose levels. Work under progress is the optimization of the technique with a larger sample of patients.

  4. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure...... at the proximal phalanx was compared in fingers I, III, IV, and V, using 16, 20, 24 and 24 mm wide cuffs. Finger blood pressure was closest to arm systolic blood pressure when a 24-mm or 27-mm-wide cuff was used in fingers I, III, and IV, and with a 20-mm-wide cuff in finger V. As the standard deviation......The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx...

  5. Cell Phone Information Seeking Explains Blood Pressure in African American Women.

    Science.gov (United States)

    Jones, Lenette M; Veinot, Tiffany C; Pressler, Susan J

    2018-05-01

    Although cell phone use and Internet access via cell phone is not marked by racial disparities, little is known about how cell phone use relates to blood pressure and health information seeking behaviors. The purposes of this study were to (a) describe Internet activities, cell phone use, and information seeking; (b) determine differences in blood pressure and information seeking between cell phone information seekers and nonseekers; and (c) examine cell phone information seeking as a predictor of blood pressure in African American women. Participants ( N = 147) completed a survey and had their blood pressure measured. Independent-sample t tests showed a significant difference in systolic blood pressure in cell phone information seekers and nonseekers. Linear regression revealed cell phone information seeking as an independent predictor of systolic blood pressure, despite confounders. It is possible that cell phone information seekers were using health information to make decisions about self-management of blood pressure.

  6. Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.

    Science.gov (United States)

    Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar

    2018-02-15

    Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.

  7. Assessing the influence of mechanical ventilation on blood gases and blood pressure in rattlesnakes

    DEFF Research Database (Denmark)

    Bertelsen, Mads Frost; Buchanan, Rasmus; Jensen, Heidi Meldgaard

    2014-01-01

    OBJECTIVE: To characterize the impact of mechanical positive pressure ventilation on heart rate (HR), arterial blood pressure, blood gases, lactate, glucose, sodium, potassium and calcium concentrations in rattlesnakes during anesthesia and the subsequent recovery period. STUDY DESIGN: Prospectiv...

  8. Effects of blood glucose, blood lipids and blood pressure control on recovery of patients with gastric cancer complicated with metabolic syndrome after radical gastrectomy.

    Science.gov (United States)

    Sun, Li; Zhou, Pingping; Hua, Qingli; Jin, Changming; Guo, Chunling; Song, Bing

    2018-06-01

    This study aimed to investigate the effects of blood glucose, blood lipids and blood pressure control on recovery of patients with gastric cancer complicated with metabolic syndrome (MS) after radical gastrectomy. A total of 150 patients with gastric cancer, who were treated in Daqing Longnan Hospital from November, 2015 to May, 2017, were enrolled in this study. The patients were divided into the MS group (80 cases) and non-MS group (70 cases). Patients in the MS group were given corresponding drugs to control blood pressure, blood lipids and blood glucose, while patients in the non-MS group were not treated with those drugs. Patients in the MS group were divided into the normal and abnormal groups according to the levels of blood glucose, blood lipids and blood pressure. Moreover, occurrences of complications were compared between the normal and abnormal groups. Before surgery, blood glucose, blood lipids and blood pressure in the MS group were significantly higher than those in the non-MS group (pblood glucose, blood lipids and blood pressure of the MS group decreased significantly compared to those before operation (pblood glucose, 2 h postprandial blood glucose, glycosylated hemoglobin, total triglycerides (TGs), LDL, mean blood pressure and BMI (pblood glucose, blood lipids and blood pressure in patients with gastric cancer complicated with MS after radical gastrectomy can reduce the incidence of postoperative complications and promote postoperative recovery.

  9. Relationship of blood lead levels and blood pressure in NHANES II: additional calculations

    International Nuclear Information System (INIS)

    Gartside, P.S.

    1988-01-01

    In performing research for associations and relationships among the data thus far published from the NHANES II survey, only the data for the 64 communities involved may be used. The simple omission of a few essential data makes impossible any valid analysis from the data for the 20,325 individual respondents. In this research for associations between blood lead levels and blood pressure in NHANES II, the method of forward stepwise regression was used. This avoids the problem of inflated error rates for blood lead, maximizes the number of data analyzed, and minimizes the number of independent variables entered into the regression model, thus avoiding the pitfalls that previous NHANES II research of blood lead and blood pressure has fallen into when using backward stepwise regression. The results of this research for white male adults, white female adults, and black adults were contradictory and lacked consistency and reliability. In addition, the overall average association between blood lead level and blood pressure was so minute that the only rational conclusion is that there is no evidence for this association to be found in the NHANES II data

  10. Regression approach to non-invasive determination of bilirubin in neonatal blood

    Science.gov (United States)

    Lysenko, S. A.; Kugeiko, M. M.

    2012-07-01

    A statistical ensemble of structural and biophysical parameters of neonatal skin was modeled based on experimental data. Diffuse scattering coefficients of the skin in the visible and infrared regions were calculated by applying a Monte-Carlo method to each realization of the ensemble. The potential accuracy of recovering the bilirubin concentration in dermis (which correlates closely with that in blood) was estimated from spatially resolved spectrometric measurements of diffuse scattering. The possibility to determine noninvasively the bilirubin concentration was shown by measurements of diffuse scattering at λ = 460, 500, and 660 nm at three source-detector separations under conditions of total variability of the skin biophysical parameters.

  11. Cuffless differential blood pressure estimation using smart phones.

    Science.gov (United States)

    Chandrasekaran, Vikram; Dantu, Ram; Jonnada, Srikanth; Thiyagaraja, Shanti; Subbu, Kalyan Pathapati

    2013-04-01

    Smart phones today have become increasingly popular with the general public for their diverse functionalities such as navigation, social networking, and multimedia facilities. These phones are equipped with high-end processors, high-resolution cameras, and built-in sensors such as accelerometer, orientation-sensor, and light-sensor. According to comScore survey, 26.2% of U.S. adults use smart phones in their daily lives. Motivated by this statistic and the diverse capability of smart phones, we focus on utilizing them for biomedical applications. We present a new application of the smart phone with its built-in camera and microphone replacing the traditional stethoscope and cuff-based measurement technique, to quantify vital signs such as heart rate and blood pressure. We propose two differential blood pressure estimating techniques using the heartbeat and pulse data. The first method uses two smart phones whereas the second method replaces one of the phones with a customized external microphone. We estimate the systolic and diastolic pressure in the two techniques by computing the pulse pressure and the stroke volume from the data recorded. By comparing the estimated blood pressure values with those measured using a commercial blood pressure meter, we obtained encouraging results of 95-100% accuracy.

  12. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  13. Evaluation of the impact of atmospheric pressure in different seasons on blood pressure in patients with arterial hypertension.

    Science.gov (United States)

    Kamiński, Marek; Cieślik-Guerra, Urszula I; Kotas, Rafał; Mazur, Piotr; Marańda, Witold; Piotrowicz, Maciej; Sakowicz, Bartosz; Napieralski, Andrzej; Trzos, Ewa; Uznańska-Loch, Barbara; Rechciński, Tomasz; Kurpesa, Małgorzata

    2016-01-01

    Atmospheric pressure is the most objective weather factor because regardless of if outdoors or indoors it affects all objects in the same way. The majority of previous studies have used the average daily values of atmospheric pressure in a bioclimatic analysis and have found no correlation with blood pressure changes. The main objective of our research was to assess the relationship between atmospheric pressure recorded with a frequency of 1 measurement per minute and the results of 24-h blood pressure monitoring in patients with treated hypertension in different seasons in the moderate climate of the City of Łódź (Poland). The study group consisted of 1662 patients, divided into 2 equal groups (due to a lower and higher average value of atmospheric pressure). Comparisons between blood pressure values in the 2 groups were performed using the Mann-Whitney U test. We observed a significant difference in blood pressure recorded during the lower and higher range of atmospheric pressure: on the days of the spring months systolic (p = 0.043) and diastolic (p = 0.005) blood pressure, and at nights of the winter months systolic blood pressure (p = 0.013). A significant inverse relationship between atmospheric pressure and blood pressure during the spring days and, only for systolic blood pressure, during winter nights was observed. Int J Occup Med Environ Health 2016;29(5):783-792. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  14. Blood pressure changes during barium enema

    International Nuclear Information System (INIS)

    Roach, S.C.; Martin, O.J.D.; Owen, A.; Martin, D.F.

    2001-01-01

    AIMS: To document blood pressure changes during barium enema examination and to determine at what point in the examination changes are likely to occur. METHODS AND RESULTS: Blood pressure measurements were taken at seven points during the course of barium enema examination in 107 consecutive patients. We found that patients over the age of 60 years had statistically significant decreases in blood pressure when they were stood up during the course of the examination. Many of these patients were asymptomatic. Patients who had symptoms (15/107, 14%) when standing up had a degree of hypotension. The duration of barium enema examination is longer in those patients who experience symptoms. CONCLUSION: During a barium enema examination hypotension occurs at the point of standing up more frequently in patients over 60 years and in those who suffer symptoms at this time. Patients who fall into one of these groups should be considered at risk of fainting at this point in the examination. A modified technique to avoid standing should be considered in at-risk patients. Roach, S.C. et al. (2001)

  15. Multicomponent exercise decreases blood pressure, heart rate and double product in normotensive and hypertensive older patients with high blood pressure.

    Science.gov (United States)

    Coelho-Júnior, Hélio José; Asano, Ricardo Yukio; Gonçalvez, Ivan de Oliveira; Brietzke, Cayque; Pires, Flávio Oliveira; Aguiar, Samuel da Silva; Feriani, Daniele Jardim; Caperuto, Erico Chagas; Uchida, Marco Carlos; Rodrigues, Bruno

    2018-02-26

    The present study aimed to investigate the effects of a 6-month multicomponent exercise program on blood pressure, heart rate, and double product of uncontrolled and controlled normotensive and hypertensive older patients. The study included 183 subjects, 97 normotensives, of which 53 were controlled normotensives (CNS), and 44 uncontrolled normotensives (UNS), as well as 86 hypertensives, of which 43 were controlled hypertensives (CHS), and 43 uncontrolled hypertensives (UHS). Volunteers were recruited and blood pressure and heart rate measurements were made before and after a 6-month multicomponent exercise program. The program of physical exercise was performed twice a week for 26 weeks. The physical exercises program was based on functional and walking exercises. Exercise sessions were performed at moderate intensity. The results indicated that UHS showed a marked decrease in systolic (-8.0mmHg), diastolic (-11.1mmHg), mean (-10.1mmHg), and pulse pressures, heart rate (-6.8bpm), and double product (-1640bpmmmHg), when compared to baseline. Similarly, diastolic (-5.5mmHg) and mean arterial (-4.8mmHg) pressures were significantly decreased in UNS. Concomitantly, significant changes could be observed in the body mass index (-0.9kg/m 2 ; -1.5kg/m 2 ) and waist circumference (-3.3cm; only UHS) of UNS and UHS, which may be associated with the changes observed in blood pressure. In conclusion, the data of the present study indicate that a 6-month multicomponent exercise program may lead to significant reductions in blood pressure, heart rate, and double product of normotensive and hypertensive patients with high blood pressure values. Copyright © 2018 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  16. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  17. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk

    NARCIS (Netherlands)

    G.B. Ehret (Georg); P. Munroe (Patricia); K.M. Rice (Kenneth); M. Bochud (Murielle); A.D. Johnson (Andrew); D.I. Chasman (Daniel); A.V. Smith (Albert Vernon); M.D. Tobin (Martin); G.C. Verwoert (Germaine); S.J. Hwang; V. Pihur (Vasyl); P. Vollenweider (Peter); P.F. O'Reilly (Paul); N. Amin (Najaf); J.L. Bragg-Gresham (Jennifer L.); A. Teumer (Alexander); N.L. Glazer (Nicole); L.J. Launer (Lenore); J.H. Zhao (Jing Hua); Y.S. Aulchenko (Yurii); S.C. Heath (Simon); S. Sõber (Siim); A. Parsa (Afshin); J. Luan; P. Arora (Pankaj); A. Dehghan (Abbas); F. Zhang (Feng); G. Lucas (Gavin); A.A. Hicks (Andrew); A.U. Jackson (Anne); J. Peden (John); T. Tanaka (Toshiko); S.H. Wild (Sarah); I. Rudan (Igor); W. Igl (Wilmar); Y. Milaneschi (Yuri); A.N. Parker (Alex); C. Fava (Cristiano); J.C. Chambers (John); E.R. Fox (Ervin); M. Kumari (Meena); M. Jin Go (Min); P. van der Harst (Pim); W. Hong Linda Kao (Wen); M. Sjögren (Marketa); D.G. Vinay; M. Alexander (Myriam); Y. Tabara (Yasuharu); S. Shaw-Hawkins (Sue); P.H. Whincup (Peter); Y. Liu (YongMei); G. Shi (Gang); J. Kuusisto (Johanna); B. Tayo (Bamidele); M. Seielstad (Mark); X. Sim (Xueling); K.-D. Hoang Nguyen; T. Lehtimäki (Terho); G. Matullo (Giuseppe); Y. Wu (Ying); T.R. Gaunt (Tom); N. Charlotte Onland-Moret; M.N. Cooper (Matthew); C. Platou (Carl); E. Org (Elin); R. Hardy (Rebecca); S. Dahgam (Santosh); J. Palmen (Jutta); V. Vitart (Veronique); P.S. Braund (Peter); T. Kuznetsova (Tatiana); C.S.P.M. Uiterwaal (Cuno); A. Adeyemo (Adebowale); W. Palmas (Walter); H. Campbell (Harry); B. Ludwig (Barbara); M. Tomaszewski; I. Tzoulaki; N.D. Palmer (Nicholette); T. Aspelund (Thor); M. Garcia (Melissa); Y.-P.C. Chang (Yen-Pei); J.R. O´Connell; N.I. Steinle (Nanette); D.E. Grobbee (Diederick); D.E. Arking (Dan); S.L. Kardia (Sharon); A.C. Morrison (Alanna); D.G. Hernandez (Dena); S.S. Najjar (Samer); W.L. McArdle (Wendy); D. Hadley (David); M.J. Brown (Morris); J. Connell (John); A. Hingorani (Aroon); I.N.M. Day (Ian); D.A. Lawlor (Debbie); J.P. Beilby (John); R.W. Lawrence (Robert); R. Clarke; J. Hopewell; H. Ongen (Halit); A.W. Dreisbach (Albert); Y. Li (Yali); J. Hunter Young; J.C. Bis (Joshua); M. Kähönen (Mika); J. Viikari (Jorma); N.R. Lee (Nanette); M-H. Chen (Ming-Huei); M. Olden (Matthias); C. Pattaro (Cristian); J.A. Hoffman Bolton (Judith); A. Köttgen (Anna); S.M. Bergmann (Sven); V. Mooser (Vincent); N. Chaturvedi (Nish); T.M. Frayling (Timothy); M. Islam (Muhammad); T.H. Jafar (Tazeen); S.R. Kulkarni (Smita); S.R. Bornstein (Stefan); J. Gräßler (Jürgen); L. Groop (Leif); B.F. Voight (Benjamin); J. Kettunen (Johannes); P. Howard (Philip); A. Taylor (Andrew); S. Guarrera (Simonetta); F. Ricceri (Fulvio); V. Emilsson (Valur); A.S. Plump (Andrew); K-T. Khaw (Kay-Tee); A.B. Weder (Alan); S.C. Hunt (Steven); Y.V. Sun (Yan); R.N. Bergman (Richard); F.S. Collins (Francis); L.L. Bonnycastle (Lori); L.J. Scott (Laura); H.M. Stringham (Heather); L. Peltonen (Leena Johanna); M. Perola (Markus); E. Vartiainen (Erkki); S.-M. Brand; J.A. Staessen (Jan); Y.A. Wang (Ying); P.R. Burton (Paul); M. Soler Artigas (Maria); Y. Dong (Yanbin); H. Snieder (Harold); H. Zhu (Haidong); K. Lohman (Kurt); M.E. Rudock (Megan); S.R. Heckbert (Susan); K.L. Wiggins (Kerri); A. Doumatey (Ayo); D. Shriner (Daniel); G. Veldre (Gudrun); M. Viigimaa (Margus); S. Kinra (Sanjay); D. Prabhakaran (Dorairaj); V. Tripathy (Vikal); C.D. Langefeld (Carl); A. Rosengren (Annika); D.S. Thelle (Dag); A. Maria Corsi (Anna); A. Singleton (Andrew); T. Forrester (Terrence); G. Hilton (Gina); C.A. McKenzie (Colin); T. Salako (Tunde); N. Iwai (Naoharu); Y. Kita (Yoshikuni); T. Ogihara (Toshio); T. Ohkubo (Takayoshi); T. Okamura (Tomonori); H. Ueshima (Hirotsugu); S. Umemura (Satoshi); S. Eyheramendy (Susana); T. Meitinger (Thomas); H.E. Wichmann (Heinz Erich); Y. Shin Cho (Yoon); H.-L. Kim; J.S. Sehmi (Joban); B. Hedblad (Bo); P. Nilsson (Peter); G. Davey-Smith (George); A. Wong (Andrew); N. Narisu (Narisu); A. Stancáková (Alena); L.J. Raffel (Leslie); J. Yao (Jie); S. Kathiresan (Sekar); C.J. O'Donnell (Christopher); S.M. Schwartz (Stephen); M.A. Ikram (Arfan); W.T. Longstreth Jr; T.H. Mosley (Thomas); S. Seshadri (Sudha); N.R.G. Shrine (Nick); L.V. Wain (Louise); M.A. Morken (Mario); A.J. Swift (Amy); J. Laitinen (Jaana); I. Prokopenko (Inga); P. Zitting (Paavo); S.E. Humphries (Steve); J. Danesh (John); A. Rasheed (Asif); A. Goel (Anuj); A. Hamsten (Anders); H. Watkins (Hugh); W.H. van Gilst (Wiek); C.S. Janipalli (Charles); K. Radha Mani; C. Yajnik (Chittaranjan); A. Hofman (Albert); F.U.S. Mattace Raso (Francesco); B.A. Oostra (Ben); A. Demirkan (Ayşe); A.J. Isaacs (Aaron); F. Rivadeneira Ramirez (Fernando); E. Lakatta (Edward); M. Orrù (Marco); A. Scuteri (Angelo); M. Ala-Korpela (Mika); A.J. Kangas (Antti); L.-P. Lyytikäinen (Leo-Pekka); P. Soininen (Pasi); T. Tukiainen (Taru); P. Würtz (Peter); R. Twee-Hee Ong (Rick); M. Dörr (Marcus); H.K. Kroemer (Heyo); U. Völker (Uwe); H. Völzke (Henry); P. Galan (Pilar); S. Hercberg (Serge); G.M. Lathrop (Mark); D. Zelenika (Diana); P. Deloukas (Panagiotis); M. Mangino (Massimo); T.D. Spector (Timothy); G. Zhai (Guangju); J.F. Meschia (James F.); M.A. Nalls (Michael); P. Sharma (Pankaj); J. Terzic (Janos); M.V. Kranthi Kumar; M. Denniff (Matthew); E. Zukowska-Szczechowska (Ewa); L.E. Wagenknecht (Lynne); F. Gerald R. Fowkes; F.J. Charchar (Fadi); P.E.H. Schwarz (Peter); C. Hayward (Caroline); X. Guo (Xiuqing); C. Rotimi (Charles); M.L. Bots (Michiel); N.J. Samani (Nilesh); O. Polasek (Ozren); P.J. Talmud (Philippa); F. Nyberg (Fredrik); D. Kuh (Diana); M. Laan (Maris); K. Hveem (Kristian); Y.T. van der Schouw (Yvonne); J.P. Casas (Juan); K.L. Mohlke (Karen); P. Vineis (Paolo); O. Raitakari (Olli); S.K. Ganesh (Santhi); E. Shyong Tai; M. Laakso (Markku); D.C. Rao (Dabeeru C.); T.B. Harris (Tamara); R.W. Morris (Richard); A. Dominiczak (Anna); M. Kivimaki (Mika); M. Marmot (Michael); T. Miki (Tetsuro); D. Saleheen; G.R. Chandak (Giriraj); J. Coresh (Josef); G. Navis (Gerjan); V. Salomaa (Veikko); B.-G. Han; J.S. Kooner (Jaspal); O. Melander (Olle); P.M. Ridker (Paul); S. Bandinelli (Stefania); U. Gyllensten (Ulf); A.F. Wright (Alan); J.F. Wilson (James); L. Ferrucci (Luigi); M. Farrall (Martin); J. Tuomilehto (Jaakko); P.P. Pramstaller (Peter Paul); R. Elosua (Roberto); N. Soranzo (Nicole); E.J.G. Sijbrands (Eric); D. Altshuler (David); R.J.F. Loos (Ruth); A.R. Shuldiner (Alan); C. Gieger (Christian); P. Meneton (Pierre); A.G. Uitterlinden (André); N.J. Wareham (Nick); V. Gudnason (Vilmundur); J.I. Rotter (Jerome); R. Rettig (Rainer); M. Uda (Manuela); D.P. Strachan (David); J.C.M. Witteman (Jacqueline); A.L. Hartikainen; J.S. Beckmann (Jacques); E.A. Boerwinkle (Eric); J. Erdmann (Jeanette); R.S. Vasan (Ramachandran Srini); M. Boehnke (Michael); M.G. Larson (Martin); M.R. Järvelin; B.M. Psaty (Bruce); P. Tikka-Kleemola (Päivi); C. Newton-Cheh (Christopher); P. Elliott (Paul); D. Levy (Daniel); M. Caulfield (Mark); G.R. Abecasis (Gonçalo); L.S. Adair (Linda); S.J.L. Bakker (Stephan); I.E. Barroso (Inês)

    2011-01-01

    textabstractBlood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140mmg Hg systolic blood pressure ≥90mmg Hg diastolic blood pressure). Even small increments in blood pressure are

  18. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  19. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk

    NARCIS (Netherlands)

    Ehret, Georg B.; Munroe, Patricia B.; Rice, Kenneth M.; Bochud, Murielle; Johnson, Andrew D.; Chasman, Daniel I.; Smith, Albert V.; Tobin, Martin D.; Verwoert, Germaine C.; Hwang, Shih-Jen; Pihur, Vasyl; Vollenweider, Peter; O'Reilly, Paul F.; Amin, Najaf; Bragg-Gresham, Jennifer L.; Teumer, Alexander; Glazer, Nicole L.; Launer, Lenore; Zhao, Jing Hua; Aulchenko, Yurii; Heath, Simon; Sõber, Siim; Parsa, Afshin; Luan, Jian'an; Arora, Pankaj; Dehghan, Abbas; Zhang, Feng; Lucas, Gavin; Hicks, Andrew A.; Jackson, Anne U.; Peden, John F.; Tanaka, Toshiko; Wild, Sarah H.; Rudan, Igor; Igl, Wilmar; Milaneschi, Yuri; Parker, Alex N.; Fava, Cristiano; Chambers, John C.; Fox, Ervin R.; Kumari, Meena; Go, Min Jin; van der Harst, Pim; Kao, Wen Hong Linda; Sjögren, Marketa; Vinay, D. G.; Alexander, Myriam; Tabara, Yasuharu; Shaw-Hawkins, Sue; Whincup, Peter H.; Liu, Yongmei; Shi, Gang; Kuusisto, Johanna; Tayo, Bamidele; Seielstad, Mark; Sim, Xueling; Nguyen, Khanh-Dung Hoang; Lehtimäki, Terho; Matullo, Giuseppe; Wu, Ying; Gaunt, Tom R.; Onland-Moret, N. Charlotte; Cooper, Matthew N.; Platou, Carl G. P.; Org, Elin; Hardy, Rebecca; Dahgam, Santosh; Palmen, Jutta; Vitart, Veronique; Braund, Peter S.; Kuznetsova, Tatiana; Uiterwaal, Cuno S. P. M.; Adeyemo, Adebowale; Palmas, Walter; Campbell, Harry; Ludwig, Barbara; Tomaszewski, Maciej; Tzoulaki, Ioanna; Palmer, Nicholette D.; Aspelund, Thor; Garcia, Melissa; Chang, Yen-Pei C.; O'Connell, Jeffrey R.; Steinle, Nanette I.; Grobbee, Diederick E.; Arking, Dan E.; Kardia, Sharon L.; Morrison, Alanna C.; Hernandez, Dena; Najjar, Samer; McArdle, Wendy L.; Hadley, David; Brown, Morris J.; Connell, John M.; Hingorani, Aroon D.; Day, Ian N. M.; Lawlor, Debbie A.; Beilby, John P.; Lawrence, Robert W.; Clarke, Robert; Hopewell, Jemma C.; Ongen, Halit; Dreisbach, Albert W.; Li, Yali; Young, J. Hunter; Bis, Joshua C.; Kähönen, Mika; Viikari, Jorma; Adair, Linda S.; Lee, Nanette R.; Chen, Ming-Huei; Olden, Matthias; Pattaro, Cristian; Bolton, Judith A. Hoffman; Köttgen, Anna; Bergmann, Sven; Mooser, Vincent; Chaturvedi, Nish; Frayling, Timothy M.; Islam, Muhammad; Jafar, Tazeen H.; Erdmann, Jeanette; Kulkarni, Smita R.; Bornstein, Stefan R.; Grässler, Jürgen; Groop, Leif; Voight, Benjamin F.; Kettunen, Johannes; Howard, Philip; Taylor, Andrew; Guarrera, Simonetta; Ricceri, Fulvio; Emilsson, Valur; Plump, Andrew; Barroso, Inês; Khaw, Kay-Tee; Weder, Alan B.; Hunt, Steven C.; Sun, Yan V.; Bergman, Richard N.; Collins, Francis S.; Bonnycastle, Lori L.; Scott, Laura J.; Stringham, Heather M.; Peltonen, Leena; Perola, Markus; Vartiainen, Erkki; Brand, Stefan-Martin; Staessen, Jan A.; Wang, Thomas J.; Burton, Paul R.; Artigas, Maria Soler; Dong, Yanbin; Snieder, Harold; Wang, Xiaoling; Zhu, Haidong; Lohman, Kurt K.; Rudock, Megan E.; Heckbert, Susan R.; Smith, Nicholas L.; Wiggins, Kerri L.; Doumatey, Ayo; Shriner, Daniel; Veldre, Gudrun; Viigimaa, Margus; Kinra, Sanjay; Prabhakaran, Dorairaj; Tripathy, Vikal; Langefeld, Carl D.; Rosengren, Annika; Thelle, Dag S.; Corsi, Anna Maria; Singleton, Andrew; Forrester, Terrence; Hilton, Gina; McKenzie, Colin A.; Salako, Tunde; Iwai, Naoharu; Kita, Yoshikuni; Ogihara, Toshio; Ohkubo, Takayoshi; Okamura, Tomonori; Ueshima, Hirotsugu; Umemura, Satoshi; Eyheramendy, Susana; Meitinger, Thomas; Wichmann, H.-Erich; Cho, Yoon Shin; Kim, Hyung-Lae; Lee, Jong-Young; Scott, James; Sehmi, Joban S.; Zhang, Weihua; Hedblad, Bo; Nilsson, Peter; Smith, George Davey; Wong, Andrew; Narisu, Narisu; Stančáková, Alena; Raffel, Leslie J.; Yao, Jie; Kathiresan, Sekar; O'Donnell, Christopher J.; Schwartz, Stephen M.; Ikram, M. Arfan; Longstreth, W. T.; Mosley, Thomas H.; Seshadri, Sudha; Shrine, Nick R. G.; Wain, Louise V.; Morken, Mario A.; Swift, Amy J.; Laitinen, Jaana; Prokopenko, Inga; Zitting, Paavo; Cooper, Jackie A.; Humphries, Steve E.; Danesh, John; Rasheed, Asif; Goel, Anuj; Hamsten, Anders; Watkins, Hugh; Bakker, Stephan J. L.; van Gilst, Wiek H.; Janipalli, Charles S.; Mani, K. Radha; Yajnik, Chittaranjan S.; Hofman, Albert; Mattace-Raso, Francesco U. S.; Oostra, Ben A.; Demirkan, Ayse; Isaacs, Aaron; Rivadeneira, Fernando; Lakatta, Edward G.; Orru, Marco; Scuteri, Angelo; Ala-Korpela, Mika; Kangas, Antti J.; Lyytikäinen, Leo-Pekka; Soininen, Pasi; Tukiainen, Taru; Würtz, Peter; Ong, Rick Twee-Hee; Dörr, Marcus; Kroemer, Heyo K.; Völker, Uwe; Völzke, Henry; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Zelenika, Diana; Deloukas, Panos; Mangino, Massimo; Spector, Tim D.; Zhai, Guangju; Meschia, James F.; Nalls, Michael A.; Sharma, Pankaj; Terzic, Janos; Kumar, M. V. Kranthi; Denniff, Matthew; Zukowska-Szczechowska, Ewa; Wagenknecht, Lynne E.; Fowkes, F. Gerald R.; Charchar, Fadi J.; Schwarz, Peter E. H.; Hayward, Caroline; Guo, Xiuqing; Rotimi, Charles; Bots, Michiel L.; Brand, Eva; Samani, Nilesh J.; Polasek, Ozren; Talmud, Philippa J.; Nyberg, Fredrik; Kuh, Diana; Laan, Maris; Hveem, Kristian; Palmer, Lyle J.; van der Schouw, Yvonne T.; Casas, Juan P.; Mohlke, Karen L.; Vineis, Paolo; Raitakari, Olli; Ganesh, Santhi K.; Wong, Tien Y.; Tai, E. Shyong; Cooper, Richard S.; Laakso, Markku; Rao, Dabeeru C.; Harris, Tamara B.; Morris, Richard W.; Dominiczak, Anna F.; Kivimaki, Mika; Marmot, Michael G.; Miki, Tetsuro; Saleheen, Danish; Chandak, Giriraj R.; Coresh, Josef; Navis, Gerjan; Salomaa, Veikko; Han, Bok-Ghee; Zhu, Xiaofeng; Kooner, Jaspal S.; Melander, Olle; Ridker, Paul M.; Bandinelli, Stefania; Gyllensten, Ulf B.; Wright, Alan F.; Wilson, James F.; Ferrucci, Luigi; Farrall, Martin; Tuomilehto, Jaakko; Pramstaller, Peter P.; Elosua, Roberto; Soranzo, Nicole; Sijbrands, Eric J. G.; Altshuler, David; Loos, Ruth J. F.; Shuldiner, Alan R.; Gieger, Christian; Meneton, Pierre; Uitterlinden, Andre G.; Wareham, Nicholas J.; Gudnason, Vilmundur; Rotter, Jerome I.; Rettig, Rainer; Uda, Manuela; Strachan, David P.; Witteman, Jacqueline C. M.; Hartikainen, Anna-Liisa; Beckmann, Jacques S.; Boerwinkle, Eric; Vasan, Ramachandran S.; Boehnke, Michael; Larson, Martin G.; Järvelin, Marjo-Riitta; Psaty, Bruce M.; Abecasis, Gonçalo R.; Chakravarti, Aravinda; Elliott, Paul; van Duijn, Cornelia M.; Newton-Cheh, Christopher; Levy, Daniel; Caulfield, Mark J.; Johnson, Toby; Tang, Hua; Knowles, Joshua; Hlatky, Mark; Fortmann, Stephen; Assimes, Themistocles L.; Quertermous, Thomas; Go, Alan; Iribarren, Carlos; Absher, Devin; Risch, Neil; Myers, Richard; Sidney, Steven; Ziegler, Andreas; Schillert, Arne; Bickel, Christoph; Sinning, Christoph; Rupprecht, Hans J.; Lackner, Karl; Wild, Philipp; Schnabel, Renate; Blankenberg, Stefan; Zeller, Tanja; Münzel, Thomas; Perret, Claire; Cambien, Francois; Tiret, Laurence; Nicaud, Viviane; Proust, Carole; Uitterlinden, Andre; van Duijn, Cornelia; Whitteman, Jaqueline; Cupples, L. Adrienne; Demissie-Banjaw, Serkalem; Ramachandran, Vasan; Smith, Albert; Folsom, Aaron; Morrison, Alanna; Chen, Ida Yii-Der; Bis, Joshua; Volcik, Kelly; Rice, Kenneth; Taylor, Kent D.; Marciante, Kristin; Smith, Nicholas; Glazer, Nicole; Heckbert, Susan; Harris, Tamara; Lumley, Thomas; Kong, Augustine; Thorleifsson, Gudmar; Thorgeirsson, Gudmundur; Holm, Hilma; Gulcher, Jeffrey R.; Stefansson, Kari; Andersen, Karl; Gretarsdottir, Solveig; Thorsteinsdottir, Unnur; Preuss, Michael; Schreiber, Stefan; König, Inke R.; Lieb, Wolfgang; Hengstenberg, Christian; Schunkert, Heribert; Fischer, Marcus; Grosshennig, Anika; Medack, Anja; Stark, Klaus; Linsel-Nitschke, Patrick; Bruse, Petra; Aherrahrou, Zouhair; Peters, Annette; Loley, Christina; Willenborg, Christina; Nahrstedt, Janja; Freyer, Jennifer; Gulde, Stephanie; Doering, Angela; Meisinger, Christina; Klopp, Norman; Illig, Thomas; Meinitzer, Andreas; Tomaschitz, Andreas; Halperin, Eran; Dobnig, Harald; Scharnagl, Hubert; Kleber, Marcus; Laaksonen, Reijo; Pilz, Stefan; Grammer, Tanja B.; Stojakovic, Tatjana; Renner, Wilfried; März, Winfried; Böhm, Bernhard O.; Winkelmann, Bernhard R.; Winkler, Karl; Hoffmann, Michael M.; Siscovick, David S.; Musunuru, Kiran; Barbalic, Maja; Guiducci, Candace; Burtt, Noel; Gabriel, Stacey B.; Stewart, Alexandre F. R.; Wells, George A.; Chen, Li; Jarinova, Olga; Roberts, Robert; McPherson, Ruth; Dandona, Sonny; Pichard, Augusto D.; Rader, Daniel J.; Devaney, Joe; Lindsay, Joseph M.; Kent, Kenneth M.; Qu, Liming; Satler, Lowell; Burnett, Mary Susan; Li, Mingyao; Reilly, Muredach P.; Wilensky, Robert; Waksman, Ron; Epstein, Stephen; Matthai, William; Knouff, Christopher W.; Waterworth, Dawn M.; Hakonarson, Hakon H.; Walker, Max C.; Hall, Alistair S.; Balmforth, Anthony J.; Wright, Benjamin J.; Nelson, Chris; Thompson, John R.; Ball, Stephen G.; Felix, Janine F.; Demissie, Serkalem; Loehr, Laura R.; Rosamond, Wayne D.; Folsom, Aaron R.; Benjamin, Emelia; Aulchenko, Yurii S.; Haritunians, Talin; Couper, David; Murabito, Joanne; Wang, Ying A.; Stricker, Bruno H.; Gottdiener, John S.; Chang, Patricia P.; Willerson, James T.; Köttgen, A.; Pattaro, C.; Böger, C. A.; Fuchsberger, C.; Olden, M.; Glazer, N. L.; Parsa, A.; Gao, X.; Yang, Q.; Smith, A. V.; O'Connell, J. R.; Li, M.; Schmidt, H.; Tanaka, T.; Isaacs, A.; Ketkar, S.; Hwang, S. J.; Johnson, A. D.; Dehghan, A.; Teumer, A.; Paré, G.; Atkinson, E. J.; Zeller, T.; Lohman, K.; Cornelis, M. C.; Probst-Hensch, N. M.; Kronenberg, F.; Tönjes, A.; Hayward, C.; Aspelund, T.; Eiriksdottir, G.; Launer, L. J.; Harris, T. B.; Rampersaud, E.; Mitchell, B. D.; Arking, D. E.; Boerwinkle, E.; Struchalin, M.; Cavalieri, M.; Singleton, A.; Giallauria, F.; Metter, J.; de Boer, J.; Haritunians, T.; Lumley, T.; Siscovick, D.; Psaty, B. M.; Zillikens, M. C.; Oostra, B. A.; Feitosa, M.; Province, M.; de Andrade, M.; Turner, S. T.; Schillert, A.; Ziegler, A.; Wild, P. S.; Schnabel, R. B.; Wilde, S.; Munzel, T. F.; Leak, T. S.; Illig, T.; Klopp, N.; Meisinger, C.; Wichmann, H. E.; Koenig, W.; Zgaga, L.; Zemunik, T.; Kolcic, I.; Minelli, C.; Hu, F. B.; Johansson, A.; Igl, W.; Zaboli, G.; Wild, S. H.; Wright, A. F.; Campbell, H.; Ellinghaus, D.; Schreiber, S.; Aulchenko, Y. S.; Felix, J. F.; Rivadeneira, F.; Uitterlinden, A. G.; Hofman, A.; Imboden, M.; Nitsch, D.; Brandstätter, A.; Kollerits, B.; Kedenko, L.; Mägi, R.; Stumvoll, M.; Kovacs, P.; Boban, M.; Campbell, S.; Endlich, K.; Völzke, H.; Kroemer, H. K.; Nauck, M.; Völker, U.; Polasek, O.; Vitart, V.; Badola, S.; Parker, A. N.; Ridker, P. M.; Kardia, S. L.; Blankenberg, S.; Liu, Y.; Curhan, G. C.; Franke, A.; Rochat, T.; Paulweber, B.; Prokopenko, I.; Wang, W.; Gudnason, V.; Shuldiner, A. R.; Coresh, J.; Schmidt, R.; Ferrucci, L.; Shlipak, M. G.; van Duijn, C. M.; Borecki, I.; Krämer, B. K.; Rudan, I.; Gyllensten, U.; Wilson, J. F.; Witteman, J. C.; Pramstaller, P. P.; Rettig, R.; Hastie, N.; Chasman, D. I.; Kao, W. H.; Heid, I. M.; Fox, C. S.; Vasan, R. S.; Lieb, W.; Felix, S. B.; Watzinger, N.; Larson, M. G.; Smith, N. L.; Grosshennig, A.; Kathiresan, S.; König, I. R.; Homuth, G.; Aragam, J.; Bis, J. C.; Erdmann, J.; Dörr, M.; Zweiker, R.; Lind, L.; Rodeheffer, R. J.; Greiser, K. H.; Levy, D.; Deckers, J. W.; Stritzke, J.; Lackner, K. J.; Ingelsson, E.; Kullo, I.; Haerting, J.; O'Donnell, C. J.; Heckbert, S. R.; Stricker, B. H.; Reffelmann, T.; Redfield, M. M.; Werdan, K.; Mitchell, G. F.; Rice, K.; Arnett, D. K.; Gottdiener, J. S.; Meitinger, T.; Blettner, M.; Friedrich, N.; Wang, T. J.; Benjamin, E. J.; Rotter, J. I.; Schunkert, H.; Chambers, J. C.; Zhang, W.; Lord, G. M.; van der Harst, P.; Lawlor, D. A.; Sehmi, J. S.; Gale, D. P.; Wass, M. N.; Ahmadi, K. R.; Bakker, S. J.; Beckmann, J.; Bilo, H. J.; Bochud, M.; Brown, M. J.; Caulfield, M. J.; Connell, J. M.; Cook, H. T.; Cotlarciuc, I.; Davey Smith, G.; de Silva, R.; Deng, G.; Devuyst, O.; Dikkeschei, L. D.; Dimkovic, N.; Dockrell, M.; Dominiczak, A.; Ebrahim, S.; Eggermann, T.; Farrall, M.; Floege, J.; Forouhi, N. G.; Gansevoort, R. T.; Han, X.; Hedblad, B.; Homan van der Heide, J. J.; Hepkema, B. G.; Hernandez-Fuentes, M.; Hypponen, E.; Johnson, T.; de Jong, P. E.; Kleefstra, N.; Lagou, V.; Lapsley, M.; Li, Y.; Loos, R. J.; Luan, J.; Luttropp, K.; Maréchal, C.; Melander, O.; Munroe, P. B.; Nordfors, L.; Peltonen, L.; Penninx, B. W.; Perucha, E.; Pouta, A.; Roderick, P. J.; Ruokonen, A.; Samani, N. J.; Sanna, S.; Schalling, M.; Schlessinger, D.; Schlieper, G.; Seelen, M. A.; Sjögren, M.; Smit, J. H.; Snieder, H.; Soranzo, N.; Spector, T. D.; Stenvinkel, P.; Sternberg, M. J.; Swaminathan, R.; Ubink-Veltmaat, L. J.; Uda, M.; Vollenweider, P.; Wallace, C.; Waterworth, D.; Zerres, K.; Waeber, G.; Wareham, N. J.; Maxwell, P. H.; McCarthy, M. I.; Jarvelin, M. R.; Mooser, V.; Abecasis, G. R.; Lightstone, L.; Scott, J.; Navis, G.; Elliott, P.; Kooner, J. S.

    2011-01-01

    Blood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140 mm Hg systolic blood pressure or  ≥90 mm Hg diastolic blood pressure). Even small increments in blood pressure are

  20. Exploring the relationship of peripheral total bilirubin, red blood cell, and hemoglobin with blood pressure during childhood and adolescence.

    Science.gov (United States)

    Chen, Xiao-Tian; Yang, Song; Yang, Ya-Ming; Zhao, Hai-Long; Chen, Yan-Chun; Zhao, Xiang-Hai; Wen, Jin-Bo; Tian, Yuan-Rui; Yan, Wei-Li; Shen, Chong

    2017-11-04

    Total bilirubin is beneficial for protecting cardiovascular diseases in adults. The authors aimed to investigate the association of total bilirubin, red blood cell, and hemoglobin levels with the prevalence of high blood pressure in children and adolescents. A total of 3776 students (aged from 6 to 16 years old) were examined using cluster sampling. Pre-high blood pressure and high blood pressure were respectively defined as the point of 90th and 95th percentiles based on the Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. Both systolic and diastolic blood pressure were standardized into z-scores. Peripheral total bilirubin, red blood cell and hemoglobin levels were significantly correlated with age, and also varied with gender. Peripheral total bilirubin was negatively correlated with systolic blood pressure in 6- and 9-year-old boys, whilst positively correlated with diastolic blood pressure in the 12-year-old boys and 13- to 15-year-old girls (p0.05). Total bilirubin could be weakly correlated with both systolic and diastolic blood pressure, as correlations varied with age and gender in children and adolescents; in turn, the increased levels of red blood cell and hemoglobin are proposed to be positively associated with the prevalence of high blood pressure. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Correlates of blood pressure in young insulin-dependent diabetics and their families.

    Science.gov (United States)

    Tarn, A C; Thomas, J M; Drury, P L

    1990-09-01

    We compared the correlates of blood pressure in 163 young patients with insulin-dependent diabetes and in 232 of their non-diabetic siblings. A single observer recorded blood pressure in all subjects, plus all their available parents, using a standardized technique. Other variables recorded included age, weight, height, presence of diabetes and urinary albumin. The major factors accounting for over 50% of the variance of systolic blood pressure (SBP) in both groups were age, weight, paternal SBP and sex. In addition, in the diabetic group the logarithm of the random urinary albumin concentration was a significant explanatory variable. For diastolic blood pressure (DBP) approximately 16% of the variance was explained by age, weight and maternal DBP. Parental blood pressure was an important determinant of blood pressure in both the diabetic and non-diabetic sibling groups. The similarity of the correlates of blood pressure in the two groups suggests that the determinants of blood pressure in young insulin-dependent diabetic patients and in the general population are similar.

  2. Radioisotope method for assessing skin blood pressure

    International Nuclear Information System (INIS)

    Tarkowska, A.; Misiunia, P.; Woytowicz, A.; Olewinski, T.

    1979-01-01

    A method of measuring the skin blood pressure (SBP) evolved by Holstein and Lassen is described. The method is based on determination of the force of pressure causing blockade of Na 131 I clearance from the site of its intradermal injection. Using this method it was found that in the lower extremities in healthy subjects the SBP approached the diastolic pressure measured by the conventional method in the brachial artery. On the other hand in patients with obliterative arteriosclerosis and in Buerger's disease the SBP was considerably lower than the diastolic arterial pressure. The authors think that the method gives a good insight into the state of blood supply to the extremities in healthy subjects and in peripheral vascular failure. (author)

  3. Dark chocolate and blood pressure: a novel study from Jordan.

    Science.gov (United States)

    Al-Safi, Saafan A; Ayoub, Nehad M; Al-Doghim, Imad; Aboul-Enein, Faisal H

    2011-11-01

    The goal of this study was to assess the effect of dark chocolate intake on cardiovascular parameters like blood pressure and heart rate values in a normotensive population. This is a randomized cross-sectional study involving a total of 14,310 adults that were selected from various regions of Jordan. Well-trained pharmacy students interviewed participants in the outpatient settings. Participants reported their weekly intake of dark chocolate that has been further classified into mild (1-2 bars/week), moderate (3-4 bars/week), and high intake ( > 4 bars/week). For each participant, the systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate were measured three times with (10-15) minute intervals in the sitting position and the resting state. The arterial blood pressure (ABP) was calculated from the measured SBP and DBP values. All measured blood pressure values were significantly decreased for participants who reported higher dark chocolate consumption. Our results showed that heart rate values were not affected by variable intake of dark chocolate. In addition, increasing dark chocolate intake was associated with a significant decrease of blood pressure values in participants irrespective of the family history of hypertension or the age of the individual. However, heart rate values were unaffected. Higher intake of dark chocolate can be associated with lower values of blood pressure, while its effect on heart rate values was not consistent.

  4. Three-Dimensional Echocardiography-Derived Non-Invasive Right Ventricular Pressure-Volume Analysis.

    Science.gov (United States)

    Huang, Kuan-Chih; Lin, Lian-Yu; Hwang, Juey-Jen; Lin, Lung-Chun

    2017-09-01

    In patients with pulmonary hypertension, repeated evaluations of right ventricular (RV) function are still required for clinical decision making, but the invasive nature of current pressure-volume analysis makes conducting regular follow-ups in a clinical setting infeasible. We enrolled 12 patients with pulmonary arterial hypertension (PAH) and 10 with pulmonary venous hypertension (PVH) May 2016-October 2016. All patients underwent a clinically indicated right heart catheterization (RHC), from which the yielded right ventricular pressure recordings were conjugated with RV volume by 3-D echocardiography to generate a pressure-volume loop. A continuous-wave Doppler envelope of tricuspid regurgitation was transformed into a pressure gradient recording by the simplified Bernoulli equation, and then a systolic pressure gradient-volume (PG-V) diagram was generated from similar methods. The area enclosed by the pressure-volume loop was calculated to represent semi-invasive right ventricular stroke work (RVSW RHC ). The area between the PG-V diagram and x-axis was calculated to estimate non-invasive RVSW (RVSW echo ). Patients with PAH have higher RV pressure, lower pulmonary arterial wedge pressure and larger RV volume that was contributed by the dilation of RV mid-cavity minor dimension. We found no significant difference of traditional parameters between these two groups, but RVSW values were significantly higher in PAH patients. The RVSW values of these two methods were significantly correlated by the equation RVSW echo  = 0.8447 RVSW RHC  + 129.38 (R 2  = 0.9151, p rights reserved.

  5. Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effects

    Directory of Open Access Journals (Sweden)

    Wu J

    2013-08-01

    Full Text Available Jun Wu1, Wei He2, Wei-min Chen1, Lian Zhu21Key Laboratory of Optoelectronic Technology and Systems, 2State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, People’s Republic of ChinaAbstract: The real-time monitoring of intracranial pressure (ICP is very important for craniocerebrally critically ill patients, but it is very difficult to realize long-time monitoring for the traditional invasive method, which very easily infects patients. Many noninvasive methods have emerged, but these have not been able to monitor ICP for long periods in real time, and they are not ready for clinical application. In order to realize long-time, online, real-time, noninvasive monitoring for ICP, a new method based on acoustoelasticity of ultrasound is herein proposed. Experimental models were devised to research the new method for experiment and simulation. Polymethyl methacrylate and hydrogel were adopted for the experiment, and their mechanical properties were very close to the real brain. A numerical solution for acoustoelasticity theory was acquired by simulating calculation based on a finite-element method. This was compared to the experimental value. The results showed a consistent match between theoretical solution and experimental value, with maximum error at most 5%. Thus, the effectiveness of the new method was verified. Theoretical and practical foundation is provided for this new method, and it could be used for animal experimentation or clinical testing in further research.Keywords: medical instruments, noninvasive, intracranial pressure, ultrasonic, acoustoelasticity, biomechanics

  6. Secular trends of blood pressure in A-bomb survivors

    International Nuclear Information System (INIS)

    Sasaki, Hideo; Kodama, Kazunori; Kitano, Koei

    1986-01-01

    There has been controversy about whether or not radiation exposure plays a major role in advancing age. To preliminarily study this relationship, a statistical analysis was made on blood pressure measurements in a cohort of A-bomb survivors for Adult Health Study carried out during a 22-year period from 1958 through 1980. Systolic blood pressure increased with advancing age in both men and women between 30 and 80 years. During the years 1974 through 1980, it tended to increase in both men and women aged in their thirties and fourties. Diastolic blood pressure for men increased between the ages of 30 and 60 years, and decreased between the ages of 60 and 80 years. It tended to increase from year to year for men. For women, it decreased prior to the 1970's, and thereafter, tended to increase. The parameters, including systolic and diastolic blood pressures and pulse pressure, were independent of exposure doses in the subgroups according to age or sex. (Namekawa, K.)

  7. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk.

    Science.gov (United States)

    Ehret, Georg B; Munroe, Patricia B; Rice, Kenneth M; Bochud, Murielle; Johnson, Andrew D; Chasman, Daniel I; Smith, Albert V; Tobin, Martin D; Verwoert, Germaine C; Hwang, Shih-Jen; Pihur, Vasyl; Vollenweider, Peter; O'Reilly, Paul F; Amin, Najaf; Bragg-Gresham, Jennifer L; Teumer, Alexander; Glazer, Nicole L; Launer, Lenore; Zhao, Jing Hua; Aulchenko, Yurii; Heath, Simon; Sõber, Siim; Parsa, Afshin; Luan, Jian'an; Arora, Pankaj; Dehghan, Abbas; Zhang, Feng; Lucas, Gavin; Hicks, Andrew A; Jackson, Anne U; Peden, John F; Tanaka, Toshiko; Wild, Sarah H; Rudan, Igor; Igl, Wilmar; Milaneschi, Yuri; Parker, Alex N; Fava, Cristiano; Chambers, John C; Fox, Ervin R; Kumari, Meena; Go, Min Jin; van der Harst, Pim; Kao, Wen Hong Linda; Sjögren, Marketa; Vinay, D G; Alexander, Myriam; Tabara, Yasuharu; Shaw-Hawkins, Sue; Whincup, Peter H; Liu, Yongmei; Shi, Gang; Kuusisto, Johanna; Tayo, Bamidele; Seielstad, Mark; Sim, Xueling; Nguyen, Khanh-Dung Hoang; Lehtimäki, Terho; Matullo, Giuseppe; Wu, Ying; Gaunt, Tom R; Onland-Moret, N Charlotte; Cooper, Matthew N; Platou, Carl G P; Org, Elin; Hardy, Rebecca; Dahgam, Santosh; Palmen, Jutta; Vitart, Veronique; Braund, Peter S; Kuznetsova, Tatiana; Uiterwaal, Cuno S P M; Adeyemo, Adebowale; Palmas, Walter; Campbell, Harry; Ludwig, Barbara; Tomaszewski, Maciej; Tzoulaki, Ioanna; Palmer, Nicholette D; Aspelund, Thor; Garcia, Melissa; Chang, Yen-Pei C; O'Connell, Jeffrey R; Steinle, Nanette I; Grobbee, Diederick E; Arking, Dan E; Kardia, Sharon L; Morrison, Alanna C; Hernandez, Dena; Najjar, Samer; McArdle, Wendy L; Hadley, David; Brown, Morris J; Connell, John M; Hingorani, Aroon D; Day, Ian N M; Lawlor, Debbie A; Beilby, John P; Lawrence, Robert W; Clarke, Robert; Hopewell, Jemma C; Ongen, Halit; Dreisbach, Albert W; Li, Yali; Young, J Hunter; Bis, Joshua C; Kähönen, Mika; Viikari, Jorma; Adair, Linda S; Lee, Nanette R; Chen, Ming-Huei; Olden, Matthias; Pattaro, Cristian; Bolton, Judith A Hoffman; Köttgen, Anna; Bergmann, Sven; Mooser, Vincent; Chaturvedi, Nish; Frayling, Timothy M; Islam, Muhammad; Jafar, Tazeen H; Erdmann, Jeanette; Kulkarni, Smita R; Bornstein, Stefan R; Grässler, Jürgen; Groop, Leif; Voight, Benjamin F; Kettunen, Johannes; Howard, Philip; Taylor, Andrew; Guarrera, Simonetta; Ricceri, Fulvio; Emilsson, Valur; Plump, Andrew; Barroso, Inês; Khaw, Kay-Tee; Weder, Alan B; Hunt, Steven C; Sun, Yan V; Bergman, Richard N; Collins, Francis S; Bonnycastle, Lori L; Scott, Laura J; Stringham, Heather M; Peltonen, Leena; Perola, Markus; Vartiainen, Erkki; Brand, Stefan-Martin; Staessen, Jan A; Wang, Thomas J; Burton, Paul R; Soler Artigas, Maria; Dong, Yanbin; Snieder, Harold; Wang, Xiaoling; Zhu, Haidong; Lohman, Kurt K; Rudock, Megan E; Heckbert, Susan R; Smith, Nicholas L; Wiggins, Kerri L; Doumatey, Ayo; Shriner, Daniel; Veldre, Gudrun; Viigimaa, Margus; Kinra, Sanjay; Prabhakaran, Dorairaj; Tripathy, Vikal; Langefeld, Carl D; Rosengren, Annika; Thelle, Dag S; Corsi, Anna Maria; Singleton, Andrew; Forrester, Terrence; Hilton, Gina; McKenzie, Colin A; Salako, Tunde; Iwai, Naoharu; Kita, Yoshikuni; Ogihara, Toshio; Ohkubo, Takayoshi; Okamura, Tomonori; Ueshima, Hirotsugu; Umemura, Satoshi; Eyheramendy, Susana; Meitinger, Thomas; Wichmann, H-Erich; Cho, Yoon Shin; Kim, Hyung-Lae; Lee, Jong-Young; Scott, James; Sehmi, Joban S; Zhang, Weihua; Hedblad, Bo; Nilsson, Peter; Smith, George Davey; Wong, Andrew; Narisu, Narisu; Stančáková, Alena; Raffel, Leslie J; Yao, Jie; Kathiresan, Sekar; O'Donnell, Christopher J; Schwartz, Stephen M; Ikram, M Arfan; Longstreth, W T; Mosley, Thomas H; Seshadri, Sudha; Shrine, Nick R G; Wain, Louise V; Morken, Mario A; Swift, Amy J; Laitinen, Jaana; Prokopenko, Inga; Zitting, Paavo; Cooper, Jackie A; Humphries, Steve E; Danesh, John; Rasheed, Asif; Goel, Anuj; Hamsten, Anders; Watkins, Hugh; Bakker, Stephan J L; van Gilst, Wiek H; Janipalli, Charles S; Mani, K Radha; Yajnik, Chittaranjan S; Hofman, Albert; Mattace-Raso, Francesco U S; Oostra, Ben A; Demirkan, Ayse; Isaacs, Aaron; Rivadeneira, Fernando; Lakatta, Edward G; Orru, Marco; Scuteri, Angelo; Ala-Korpela, Mika; Kangas, Antti J; Lyytikäinen, Leo-Pekka; Soininen, Pasi; Tukiainen, Taru; Würtz, Peter; Ong, Rick Twee-Hee; Dörr, Marcus; Kroemer, Heyo K; Völker, Uwe; Völzke, Henry; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Zelenika, Diana; Deloukas, Panos; Mangino, Massimo; Spector, Tim D; Zhai, Guangju; Meschia, James F; Nalls, Michael A; Sharma, Pankaj; Terzic, Janos; Kumar, M V Kranthi; Denniff, Matthew; Zukowska-Szczechowska, Ewa; Wagenknecht, Lynne E; Fowkes, F Gerald R; Charchar, Fadi J; Schwarz, Peter E H; Hayward, Caroline; Guo, Xiuqing; Rotimi, Charles; Bots, Michiel L; Brand, Eva; Samani, Nilesh J; Polasek, Ozren; Talmud, Philippa J; Nyberg, Fredrik; Kuh, Diana; Laan, Maris; Hveem, Kristian; Palmer, Lyle J; van der Schouw, Yvonne T; Casas, Juan P; Mohlke, Karen L; Vineis, Paolo; Raitakari, Olli; Ganesh, Santhi K; Wong, Tien Y; Tai, E Shyong; Cooper, Richard S; Laakso, Markku; Rao, Dabeeru C; Harris, Tamara B; Morris, Richard W; Dominiczak, Anna F; Kivimaki, Mika; Marmot, Michael G; Miki, Tetsuro; Saleheen, Danish; Chandak, Giriraj R; Coresh, Josef; Navis, Gerjan; Salomaa, Veikko; Han, Bok-Ghee; Zhu, Xiaofeng; Kooner, Jaspal S; Melander, Olle; Ridker, Paul M; Bandinelli, Stefania; Gyllensten, Ulf B; Wright, Alan F; Wilson, James F; Ferrucci, Luigi; Farrall, Martin; Tuomilehto, Jaakko; Pramstaller, Peter P; Elosua, Roberto; Soranzo, Nicole; Sijbrands, Eric J G; Altshuler, David; Loos, Ruth J F; Shuldiner, Alan R; Gieger, Christian; Meneton, Pierre; Uitterlinden, Andre G; Wareham, Nicholas J; Gudnason, Vilmundur; Rotter, Jerome I; Rettig, Rainer; Uda, Manuela; Strachan, David P; Witteman, Jacqueline C M; Hartikainen, Anna-Liisa; Beckmann, Jacques S; Boerwinkle, Eric; Vasan, Ramachandran S; Boehnke, Michael; Larson, Martin G; Järvelin, Marjo-Riitta; Psaty, Bruce M; Abecasis, Gonçalo R; Chakravarti, Aravinda; Elliott, Paul; van Duijn, Cornelia M; Newton-Cheh, Christopher; Levy, Daniel; Caulfield, Mark J; Johnson, Toby

    2011-09-11

    Blood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140 mm Hg systolic blood pressure or  ≥90 mm Hg diastolic blood pressure). Even small increments in blood pressure are associated with an increased risk of cardiovascular events. This genome-wide association study of systolic and diastolic blood pressure, which used a multi-stage design in 200,000 individuals of European descent, identified sixteen novel loci: six of these loci contain genes previously known or suspected to regulate blood pressure (GUCY1A3-GUCY1B3, NPR3-C5orf23, ADM, FURIN-FES, GOSR2, GNAS-EDN3); the other ten provide new clues to blood pressure physiology. A genetic risk score based on 29 genome-wide significant variants was associated with hypertension, left ventricular wall thickness, stroke and coronary artery disease, but not kidney disease or kidney function. We also observed associations with blood pressure in East Asian, South Asian and African ancestry individuals. Our findings provide new insights into the genetics and biology of blood pressure, and suggest potential novel therapeutic pathways for cardiovascular disease prevention.

  8. Hypertension. Age-specificity of blood-pressure-associated complications

    OpenAIRE

    Staessen, Jan A

    2014-01-01

    In an analysis of electronic health records, 1.25 million patients aged ≥30 years without diagnosed cardiovascular disease experienced 83,098 cardiovascular events during follow-up (median 5.2 years). Associations between incident cardiovascular disease and blood pressure differed for systolic and diastolic blood pressures and between the 12 cardiovascular end points examined.

  9. A Calibrated Method of Massage Therapy Decreases Systolic Blood Pressure Concomitant With Changes in Heart Rate Variability in Male Rats.

    Science.gov (United States)

    Spurgin, Kurt A; Kaprelian, Anthony; Gutierrez, Roberto; Jha, Vidyasagar; Wilson, Christopher G; Dobyns, Abigail; Xu, Karen H; Curras-Collazo, Margarita C

    2017-02-01

    The purpose of this study was to develop a method for applying calibrated manual massage pressures by using commonly available, inexpensive sphygmomanometer parts and validate the use of this approach as a quantitative method of applying massage therapy to rodents. Massage pressures were monitored by using a modified neonatal blood pressure (BP) cuff attached to an aneroid gauge. Lightly anesthetized rats were stroked on the ventral abdomen for 5 minutes at pressures of 20 mm Hg and 40 mm Hg. Blood pressure was monitored noninvasively for 20 minutes following massage therapy at 5-minute intervals. Interexaminer reliability was assessed by applying 20 mm Hg and 40 mm Hg pressures to a digital scale in the presence or absence of the pressure gauge. With the use of this method, we observed good interexaminer reliability, with intraclass coefficients of 0.989 versus 0.624 in blinded controls. In Long-Evans rats, systolic BP dropped by an average of 9.86% ± 0.27% following application of 40 mm Hg massage pressure. Similar effects were seen following 20 mm Hg pressure (6.52% ± 1.7%), although latency to effect was greater than at 40 mm Hg. Sprague-Dawley rats behaved similarly to Long-Evans rats. Low-frequency/high-frequency ratio, a widely-used index of autonomic tone in cardiovascular regulation, showed a significant increase within 5 minutes after 40 mm Hg massage pressure was applied. The calibrated massage method was shown to be a reproducible method for applying massage pressures in rodents and lowering BP. Copyright © 2016. Published by Elsevier Inc.

  10. Integrated fiber optical and thermal sensor for noninvasive monitoring of blood and human tissue

    Science.gov (United States)

    Saetchnikov, Vladimir A.; Tcherniavskaia, Elina A.; Schiffner, Gerhard

    2007-05-01

    A novel concept of noninvasive monitoring of human tissue and blood based on optical diffuse reflective spectroscopy combined with metabolic heat measurements has been under development. A compact integrated fiber optical and thermal sensor has been developed. The idea of the method was to evaluate by optical spectroscopy haemoglobin and derivative concentrations and supplement with data associated with the oxidative metabolism of glucose. Body heat generated by glucose oxidation is based on the balance of capillary glucose and oxygen supply to the cells. The variation in glucose concentration is followed also by a difference from a distance (or depth) of scattered through the body radiation. So, blood glucose can be estimated by measuring the body heat and the oxygen supply. The sensor pickup contains of halogen lamp and LEDs combined with fiber optical bundle to deliver optical radiation inside and through the patient body, optical and thermal detectors. Fiber optical probe allows diffuse scattering measurement down to a depth of 2.5 mm in the skin including vascular system, which contributes to the control of the body temperature. The sensor pickup measures thermal generation, heat balance, blood flow rate, haemoglobin and derivative concentrations, environmental conditions. Multivariate statistical analysis was applied to convert various signals from the sensor pickup into physicochemical variables. By comparing the values from the noninvasive measurement with the venous plasma result, analytical functions for patient were obtained. Cluster analysis of patient groups was used to simplify a calibration procedure. Clinical testing of developed sensor is being performed.

  11. Associations of ambulatory blood pressure with urinary caffeine and caffeine metabolite excretions.

    Science.gov (United States)

    Guessous, Idris; Pruijm, Menno; Ponte, Belén; Ackermann, Daniel; Ehret, Georg; Ansermot, Nicolas; Vuistiner, Philippe; Staessen, Jan; Gu, Yumei; Paccaud, Fred; Mohaupt, Markus; Vogt, Bruno; Pechère-Bertschi, Antoinette; Pechère-Berstchi, Antoinette; Martin, Pierre-Yves; Burnier, Michel; Eap, Chin B; Bochud, Murielle

    2015-03-01

    Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure. © 2014 American Heart Association, Inc.

  12. Blood pressure and heart rate variability analysis of orthostatic challenge in normal human pregnancies.

    Science.gov (United States)

    Heiskanen, Nonna; Saarelainen, Heli; Valtonen, Pirjo; Lyyra-Laitinen, Tiina; Laitinen, Tomi; Vanninen, Esko; Heinonen, Seppo

    2008-11-01

    The aim of the present study was to evaluate pregnancy-related changes in autonomic regulatory functions in healthy subjects. We studied cardiovascular autonomic responses to head-up tilt (HUT) in 28 pregnant women during the third trimester of pregnancy and 3 months after parturition. The maternal ECG and non-invasive beat-to-beat blood pressure were recorded in the horizontal position (left-lateral position) and during HUT in the upright position. Stroke volume was assessed from blood pressure signal by using the arterial pulse contour method. Heart rate variability (HRV) was analysed in frequency domain, and baroreflex sensitivity by the cross-spectral and the sequence methods. In the horizontal position, all frequency components of HRV were lower during pregnancy than 3 months after parturition (P pregnancy had no influence on normalized low frequency and high frequency powers. During pregnancy haemodynamics was well balanced with only minor changes in response to postural change while haemodynamic responses to HUT were more remarkable after parturition. In pregnant women HRV and especially its very low frequency component increased in response to HUT, whereas at 3 months after parturition the direction of these changes was opposite. Parasympathetic deactivation towards term is likely to contribute to increased heart rate and cardiac output at rest, whereas restored sympathetic modulation with modest responses may contribute stable peripheral resistance and sufficient placental blood supply under stimulated conditions. It is important to understand cardiovascular autonomic nervous system and haemodynamic control in normal pregnancy before being able to judge whether they are dysregulated in complicated pregnancies.

  13. Association between parity and breastfeeding with maternal high blood pressure.

    Science.gov (United States)

    Lupton, Samantha J; Chiu, Christine L; Lujic, Sanja; Hennessy, Annemarie; Lind, Joanne M

    2013-06-01

    The objective of this study was to determine how parity and breastfeeding were associated with maternal high blood pressure, and how age modifies this association. Baseline data for 74,785 women were sourced from the 45 and Up Study, Australia. These women were 45 years of age or older, had an intact uterus, and had not been diagnosed with high blood pressure before pregnancy. Odds ratios (ORs) and 99% confidence intervals (CIs) for the association between giving birth, breastfeeding, lifetime breastfeeding duration, and average breastfeeding per child with high blood pressure were estimated using logistic regression. The combination of parity and breastfeeding was associated with lower odds of having high blood pressure (adjusted OR, 0.89; 99% CI, 0.82-0.97; P high blood pressure when compared with parous women who never breastfed. The odds were lower with longer breastfeeding durations and were no longer significant in the majority of women over the age of 64 years. Women should be encouraged to breastfeed for as long as possible and a woman's breastfeeding history should be taken into account when assessing her likelihood of high blood pressure in later life. Copyright © 2013 Mosby, Inc. All rights reserved.

  14. Blood pressure associates with standing balance in elderly outpatients.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available OBJECTIVES: Assessment of the association of blood pressure measurements in supine and standing position after a postural change, as a proxy for blood pressure regulation, with standing balance in a clinically relevant cohort of elderly, is of special interest as blood pressure may be important to identify patients at risk of having impaired standing balance in routine geriatric assessment. MATERIALS AND METHODS: In a cross-sectional cohort study, 197 community-dwelling elderly referred to a geriatric outpatient clinic of a middle-sized teaching hospital were included. Blood pressure was measured intermittently (n = 197 and continuously (subsample, n = 58 before and after a controlled postural change from supine to standing position. The ability to maintain standing balance was assessed during ten seconds of side-by-side, semi-tandem and tandem stance, with both eyes open and eyes closed. Self-reported impaired standing balance and history of falls were recorded by questionnaires. Logistic regression analyses were used to examine the association between blood pressure and 1 the ability to maintain standing balance; 2 self-reported impaired standing balance; and 3 history of falls, adjusted for age and sex. RESULTS: Blood pressure decrease after postural change, measured continuously, was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed and with increased self-reported impaired standing balance and falls. Presence of orthostatic hypotension was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed for both intermittent and continuous measurements and with increased self-reported impaired standing balance for continuous measurements. CONCLUSION: Continuous blood pressure measurements are of additional value to identify patients at risk of having impaired standing balance and may therefore be useful in routine geriatric care.

  15. Elevated preoperative blood pressures in adult surgical patients are highly predictive of elevated home blood pressures.

    Science.gov (United States)

    Schonberger, Robert B; Nwozuzu, Adambeke; Zafar, Jill; Chen, Eric; Kigwana, Simon; Monteiro, Miriam M; Charchaflieh, Jean; Sophanphattana, Sophisa; Dai, Feng; Burg, Matthew M

    2018-04-01

    Blood pressure (BP) measurement during the presurgical assessment has been suggested as a way to improve longitudinal detection and treatment of hypertension. The relationship between BP measured during this assessment and home blood pressure (HBP), a better indicator of hypertension, is unknown. The purpose of the present study was to determine the positive predictive value of presurgical BP for predicting elevated HBP. We prospectively enrolled 200 patients at a presurgical evaluation clinic with clinic blood pressures (CBPs) ≥130/85 mm Hg, as measured using a previously validated automated upper-arm device (Welch Allyn Vital Sign Monitor 6000 Series), to undergo daily HBP monitoring (Omron Model BP742N) between the index clinic visit and their day of surgery. Elevated HBP was defined, per American Heart Association guidelines, as mean systolic HBP ≥135 mm Hg or mean diastolic HBP ≥85 mm Hg. Of the 200 participants, 188 (94%) returned their home blood pressure monitors with valid data. The median number of HBP recordings was 10 (interquartile range, 7-14). Presurgical CBP thresholds of 140/90, 150/95, and 160/100 mm Hg yielded positive predictive values (95% confidence interval) for elevated HBP of 84.1% (0.78-0.89), 87.5% (0.81-0.92), and 94.6% (0.87-0.99), respectively. In contrast, self-reported BP control, antihypertensive treatment, availability of primary care, and preoperative pain scores demonstrated poor agreement with elevated HBP. Elevated preoperative CBP is highly predictive of longitudinally elevated HBP. BP measurement during presurgical assessment may provide a way to improve longitudinal detection and treatment of hypertension. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.

  16. Quantitative and qualitative retinal microvascular characteristics and blood pressure.

    Science.gov (United States)

    Cheung, Carol Y; Tay, Wan T; Mitchell, Paul; Wang, Jie J; Hsu, Wynne; Lee, Mong L; Lau, Qiangfeng P; Zhu, Ai L; Klein, Ronald; Saw, Seang M; Wong, Tien Y

    2011-07-01

    The present study examined the effects of blood pressure on a spectrum of quantitative and qualitative retinal microvascular signs. Retinal photographs from the Singapore Malay Eye Study, a population-based cross-sectional study of 3280 (78.7% response) persons aged 40-80 years, were analyzed. Quantitative changes in the retinal vasculature (branching angle, vascular tortuosity, fractal dimension, and vascular caliber) were measured using a semi-automated computer-based program. Qualitative signs, including focal arteriolar narrowing (FAN), arteriovenous nicking (AVN), opacification of the arteriolar wall (OAW), and retinopathy (e.g., microaneurysms, retinal hemorrhages), were assessed from photographs by trained technicians. After excluding persons with diabetes and ungradable photographs, 1913 persons provided data for this analysis. In multivariable linear regression models controlling for age, sex, BMI, use of antihypertensive medication, and other factors, retinal arteriolar branching asymmetry ratio, arteriolar tortuosity, venular tortuosity, fractal dimension, arteriolar caliber, venular caliber, FAN, AVN, and retinopathy were independently associated with mean arterial blood pressure. In contrast, arteriolar/venular branching angle, venular branching asymmetry ratio and OAW were not related to blood pressure. Retinal arteriolar caliber (sβ = -0.277) and FAN (sβ = 0.170) had the strongest associations with mean arterial blood pressure, and higher blood pressure levels were associated with increasing number of both quantitative and qualitative retinal vascular signs (P trend qualitative retinal vascular signs, with the number of signs increasing with higher blood pressure levels.

  17. High Blood Pressure and Women

    Science.gov (United States)

    ... is known as gestational hypertension, a form of secondary hypertension caused by the pregnancy that usually disappears after delivery. If the mother is not treated, high blood pressure can be dangerous to both the mother ...

  18. Get the Most Out of Home Blood Pressure Monitoring

    Science.gov (United States)

    Get the most out of home blood pressure monitoring Checking your blood pressure at home is an important part of managing ... monitors might not give you an accurate reading. Most pharmacies, medical supply stores and some websites sell ...

  19. High Blood Pressure and Cold Remedies: Which Are Safe?

    Science.gov (United States)

    ... counter cold remedies safe for people who have high blood pressure? Answers from Sheldon G. Sheps, M.D. Over- ... remedies aren't off-limits if you have high blood pressure, but it's important to make careful choices. Among ...

  20. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  1. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  2. Chagas disease, a risk factor for high blood pressure.

    Science.gov (United States)

    Vicco, Miguel Hernán; Rodeles, Luz; Yódice, Agustina; Marcipar, Iván

    2014-12-01

    Chagas disease is a parasite infection caused by the protozoan Trypanosoma cruzi. Its most common complications is chronic Chagas heart disease but impairments of the systemic vasculature also has been observed. Although the different mechanisms that regulate blood pressure are disrupted, to our knowledge data on the association of hypertension and chronic Chagas disease are scarce. In this regard we evaluate whether Chagas disease constitutes a high blood pressure risk factor. We recruited 200 individuals, half of them with positive serology for T. cruzi. They were subjected to a complete clinical examination. The mean age of sampled individuals was 46.7 ± 12.3, and the mean of systolic and diastolic blood pressure were 124 ± 12 mmHg and 82 ± 10 mmHg, respectively. There were no between-group differences regarding age, sex distribution or body mass index. Chagas disease contributed significantly to high blood pressure (OR = 4, 95% CI 1.8323-7.0864, p = 0.0002). Our results reveal an important association between Chagas disease and high blood pressure, which should be contemplated by physicians in order to promote preventive cardiovascular actions in patients with Chagas disease.

  3. Dairy consumption, systolic blood pressure, and risk of hypertension

    DEFF Research Database (Denmark)

    Ding, Ming; Huang, Tao; Bergholdt, Helle Km

    2017-01-01

    Objective To examine whether previous observed inverse associations of dairy intake with systolic blood pressure and risk of hypertension were causal.Design Mendelian randomization study using the single nucleotide polymorphism rs4988235 related to lactase persistence as an instrumental variable...... blood pressure but not risk of hypertension (odds ratio 0.98, 0.97 to 1.00; P=0.11).Conclusion The weak inverse association between dairy intake and systolic blood pressure in observational studies was not supported by a comprehensive instrumental variable analysis and systematic review of existing...

  4. High Blood Pressure, Afib and Your Risk of Stroke

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More High Blood Pressure, AFib and Your Risk of Stroke Updated:Aug ... have a stroke for the first time have high blood pressure . And an irregular atrial heart rhythm — a condition ...

  5. High Blood Pressure in Adolescents of Curitiba: Prevalence and Associated Factors.

    Science.gov (United States)

    Bozza, Rodrigo; Campos, Wagner de; Barbosa Filho, Valter Cordeiro; Stabelini Neto, Antonio; Silva, Michael Pereira da; Maziero, Renato Silva Barbosa

    2016-05-01

    Arterial hypertension is a major public health problem and has increased considerably in young individuals in past years. Thus, identifying factors associated with this condition is important to guide intervention strategies in this population. To determine high blood pressure prevalence and its associated factors in adolescents. A random sample of 1,242 students enrolled in public schools of the city of Curitiba (PR) was selected. Self-administered questionnaires provided family history of hypertension, daily energy expenditure, smoking habit, daily fat intake, and socioeconomic status. Waist circumference was measured following standardized procedures, and blood pressure was measured with appropriate cuffs in 2 consecutive days to confirm high blood pressure. Relative frequency and confidence interval (95%CI) indicated high blood pressure prevalence. Bivariate and multivariate analyses assessed the association of risk factors with high blood pressure. The high blood pressure prevalence was 18.2% (95%CI 15.2-21.6). Individuals whose both parents had hypertension [odds ratio (OR), 2.22; 95%CI 1.28-3.85] and those with high waist circumference (OR, 2.1; 95%CI 1.34-3.28) had higher chances to develop high blood pressure. Positive family history of hypertension and high waist circumference were associated with high blood pressure in adolescents. These factors are important to guide future interventions in this population.

  6. High Blood Pressure in Adolescents of Curitiba: Prevalence and Associated Factors

    Directory of Open Access Journals (Sweden)

    Rodrigo Bozza

    2016-01-01

    Full Text Available Abstract Background: Arterial hypertension is a major public health problem and has increased considerably in young individuals in past years. Thus, identifying factors associated with this condition is important to guide intervention strategies in this population. Objective: To determine high blood pressure prevalence and its associated factors in adolescents. Methods: A random sample of 1,242 students enrolled in public schools of the city of Curitiba (PR was selected. Self-administered questionnaires provided family history of hypertension, daily energy expenditure, smoking habit, daily fat intake, and socioeconomic status. Waist circumference was measured following standardized procedures, and blood pressure was measured with appropriate cuffs in 2 consecutive days to confirm high blood pressure. Relative frequency and confidence interval (95%CI indicated high blood pressure prevalence. Bivariate and multivariate analyses assessed the association of risk factors with high blood pressure. Results: The high blood pressure prevalence was 18.2% (95%CI 15.2-21.6. Individuals whose both parents had hypertension [odds ratio (OR, 2.22; 95%CI 1.28-3.85] and those with high waist circumference (OR, 2.1; 95%CI 1.34-3.28 had higher chances to develop high blood pressure. Conclusion: Positive family history of hypertension and high waist circumference were associated with high blood pressure in adolescents. These factors are important to guide future interventions in this population.

  7. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  8. Perceived unfairness at work, social and personal resources, and resting blood pressure.

    Science.gov (United States)

    Ford, Michael T

    2014-02-01

    By drawing from theoretical perspectives suggesting that unfair conditions threaten fundamental psychological needs, perceived unfairness at work was proposed and tested as a predictor of resting blood pressure. As part of the Midlife Development in the United States Biomarkers project, participants completed questionnaires measuring perceived unfairness, self-esteem and coworker support. Resting blood pressure readings were also recorded as part of a larger physical examination. Results indicate that perceived unfairness at work was associated with higher resting diastolic and systolic blood pressure. Perceived unfairness was most strongly related to diastolic and systolic blood pressure among women with low levels of coworker support. Contrary to predictions, self-esteem did not moderate the association between perceived unfairness and blood pressure. These results suggest that high blood pressure may be a mechanism linking unfairness to negative health outcomes and point to coworker support as a moderator of the perceived unfairness-blood pressure relationship among women. Further research is needed exploring the mediating mechanisms linking unfair treatment at work to blood pressure and health. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Perinatal development and adult blood pressure

    Directory of Open Access Journals (Sweden)

    N. Ashton

    2000-07-01

    Full Text Available A growing body of evidence supports the concept of fetal programming in cardiovascular disease in man, which asserts that an insult experienced in utero exerts a long-term influence on cardiovascular function, leading to disease in adulthood. However, this hypothesis is not universally accepted, hence animal models may be of value in determining potential physiological mechanisms which could explain how fetal undernutrition results in cardiovascular disease in later life. This review describes two major animal models of cardiovascular programming, the in utero protein-restricted rat and the cross-fostered spontaneously hypertensive rat. In the former model, moderate maternal protein restriction during pregnancy induces an increase in offspring blood pressure of 20-30 mmHg. This hypertensive effect is mediated, in part, by fetal exposure to excess maternal glucocorticoids as a result of a deficiency in placental 11-ß hydroxysteroid dehydrogenase type 2. Furthermore, nephrogenesis is impaired in this model which, coupled with increased activity of the renin-angiotensin system, could also contribute to the greater blood pressure displayed by these animals. The second model discussed is the cross-fostered spontaneously hypertensive rat. Spontaneously hypertensive rats develop severe hypertension without external intervention; however, their adult blood pressure may be lowered by 20-30 mmHg by cross-fostering pups to a normotensive dam within the first two weeks of lactation. The mechanisms responsible for this antihypertensive effect are less clear, but may also involve altered renal function and down-regulation of the renin-angiotensin system. These two models clearly show that adult blood pressure is influenced by exposure to one of a number of stimuli during critical stages of perinatal development.

  10. Does the serum uric acid level have any relation to arterial stiffness or blood pressure in adults with congenital renal agenesis and/or hypoplasia?

    Science.gov (United States)

    Yazici, Raziye; Guney, İbrahim; Altintepe, Lutfullah; Yazici, Mehmet

    2017-01-01

    The relationship between serum uric acid and arterial stiffness or blood pressure is not clear. The serum uric acid level and its association with cardiovascular risk is not well known in patients with reduced renal mass. We aimed to investigate the relation between serum uric acid levels and arterial stiffness and also blood pressure in patients with congenital renal agenesis and/or hypoplasia. In this single center, cross-sectional study, a total of 55 patients (39 (% 70.9) with unilateral small kidney and 16 (%29.1) with renal agenesis) were included. The median age was 35 (21-50) years. The study population was divided into tertiles of serum uric acid (according to 2.40-3.96, 3.97-5.10, and 5.11-9.80 mg/dl cut-off values of serum uric acid levels). Official and 24-h ambulatory non-invasive blood pressures of all patients were measured. The arterial stiffness was assessed by pulse wave velocity (PWV). PWV values were increased from first to third tertile (5.5 ± 0.6, 5.7 ± 0.8, 6.1 ± 0.7, respectively), but this gradual increase between tertiles did not reach significance. Linear regression analyses showed a positive correlation between serum uric acid levels and PWV (β = 0.40, p = 0.010), but no correlation was found between uric acid and daytime systolic blood pressure (β = 0.24, p = 0.345). In congenital renal agenesis/hypoplasia, the serum uric acid level was positively correlated with arterial stiffness, but there was no correlation with blood pressure.

  11. Gastrointestinal passage of [125I]Na and blood clearance of 125I-labelled bacteria recorded with a simple non-invasive technique

    International Nuclear Information System (INIS)

    Sundqvist, T.; Skogh, T.

    1982-01-01

    To measure blood concentrations of radiolabelled particles or substances, blood sampling is generally required. The kinetics of radioactivity variations in the blood can be studied by blood sampling from each individual or experimental animal. Alternatively blood samples can be taken from different individuals at different time points. With either of these methods it is difficult to predict the optimal time points for blood sampling, and important information can easily be missed, especially in rapid processes. In this study a simple non-invasive technique for continuous recording of blood radioactivity concentrations in mice is presented. (Auth.)

  12. Multiplex PCR from Menstrual Blood: A Non-Invasive Cost-Effective Approach to Reduce Diagnostic Dilemma for Genital Tuberculosis.

    Science.gov (United States)

    Paine, Suman K; Basu, Analabha; Choudhury, Rajib Gon; Bhattacharya, Basudev; Chatterjee, Sidhartha; Bhattacharya, Chandra

    2018-03-16

    Genital tuberculosis (GTB) is a potent contributor to irreversible damage to the reproductive system and infertility in females. As no gold standard diagnostic tool is yet available, clinical suspicion and relatively insensitive approaches such as histopathology, laparoscopy and hysterosalpingogram are currently critical determinants in the diagnosis of GTB. Although a polymerase chain reaction (PCR)-based assay using endometrial tissue seems promising, sampling does require an invasive procedure. We hypothesized that menstrual blood may provide an alternate non-invasive source of samples for PCR-based GTB diagnosis. We enrolled 195 women with primary infertility in whom GTB was suspected. We obtained ethics committee approval from our institution and written informed consent from subjects. Endometrial tissue and menstrual blood was collected from the subjects and culture, histopathology, and multiplex PCR with both sample type was performed for each subject. The sensitivity and specificity of multiplex PCR was, respectively, 90.2 and 86.1% for menstrual blood, 95.8 and 84.3% for endometrial tissue, and 64.8 and 93.2% for histopathology staining. A strong clinical suspicion aided with multiplex PCR using menstrual blood may significantly reduce the diagnostic dilemma for GTB diagnosis in a non-invasive, sensitive, rapid, and cost-effective manner.

  13. Pressure passive cerebral blood flow and breakdown of the blood-brain barrier in experimental fetal asphyxia

    DEFF Research Database (Denmark)

    Lou, H C; Lassen, N A; Tweed, W A

    1979-01-01

    reaching CBF values up to 6 times normal at normal MABP of about 60 to 70 mmHg, and severe ischemia reaching CBF values close to zero in large cortical areas at MABP of 30 mmHg. CVP remained essentially unchanged at 10--15 mmHg. The severe and prolonged asphyxia rendered the blood-brain barrier leaky......Cerebral blood flow (CBF) was studied in non-exteriorized near-term sheep fetuses using the radioactive microsphere technique. By partially occluding the umbilical vessels for a period of 1--1 1/2 hours a progressive and severe asphyxia with a final arterial pH of 6.90 was achieved. Varying...... the mean arterial blood pressure in the fetuses by blood withdrawal or infusion in this state, CBF was measured at different perfusion pressures (mean arterial blood pressure (MABP) minus central venous pressure (CVP)). A passive flow/pressure relationship--loss of autoregulation--was found, with hyperemia...

  14. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  15. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  16. Daily blood pressure profile in Cushing's syndrome before and after surgery

    Directory of Open Access Journals (Sweden)

    Kreze A.

    1999-01-01

    Full Text Available No significant difference has been demonstrated in the altered circadian blood pressure pattern between the pituitary-dependent and adrenal forms of Cushing's syndrome before surgery. The effect of therapy, however, proved to be different. The mesor was normalized in the pituitary-dependent Cushing's syndrome more conspicuously for systolic than for diastolic blood pressure. In Cushing's syndrome due to adrenal adenoma, systolic and diastolic blood pressure mesors have been even significantly "overnormalized" after treatment, being 11 to 27 and 2 to 13 mmHg (95% confidence lower than corresponding mesors in controls. There was no difference between forms in the effect of treatment on blood pressure amplitudes, which remained significantly lower than in controls. Finally, acrophase patterns were partly normalized after treatment of the pituitary-dependent form only for diastolic blood pressure, while both systolic and diastolic blood pressure acrophases were normalized in the treated adrenal form. In conclusion, complete normalization of the pattern of daily blood pressure profile has not been achieved in either form of the syndrome. This may be one of the reasons for the reduced long-term survival after surgical cure of hypercortisolism, than expected.

  17. Effects of salt substitute on home blood pressure differs according to age and degree of blood pressure in hypertensive patients and their families.

    Science.gov (United States)

    Hu, Jihong; Zhao, Liancheng; Thompson, Brian; Zhang, Yawei; Wu, Yangfeng

    2018-02-05

    It is known that home blood pressure (HBP) is a more reliable assessment of hypertension treatments than clinical blood pressure (BP). Despite this, HBP response to a salt substitute has only been evaluated by one study which, did not look at the salt substitute's effect on family members and did not analyze by age, gender, or BP degree. The aim of this current study was to assess the effects of a low-sodium and high-potassium salt substitute on HBP among hypertensive patients and their family members. A total of 220 households (including 220 hypertensive patients and 380 their families) were randomly assigned to the regular salt or salt substitute groups. HBP was measured at the beginning, 3rd, 6th, and 12th months. Among the patients (n = 220), only home systolic blood pressure (HSBP) was significantly reduced, by an adjusted baseline BP of 4.2 mm Hg (95% CI: 1.3-7.0 mm Hg), in the salt substitute group compared with those in the regular salt group at each visit (all P blood pressure (HDBP) at any visit. Among the family members, HSBP and HDBP were not significantly different between the groups. Furthermore, Individuals ≥60 years old, hypertensive patients with stage-2 hypertension, family members with hypertension, and women experienced greater HSBP reduction. Older subjects, those with higher blood pressure, and women experienced greater home blood pressure reduction from the salt substitute compared to regular salt.

  18. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure: a pooled analysis of 1018 population-based measurement studies with 88.6 million participants.

    Science.gov (United States)

    2018-03-19

    Change in the prevalence of raised blood pressure could be due to both shifts in the entire distribution of blood pressure (representing the combined effects of public health interventions and secular trends) and changes in its high-blood-pressure tail (representing successful clinical interventions to control blood pressure in the hypertensive population). Our aim was to quantify the contributions of these two phenomena to the worldwide trends in the prevalence of raised blood pressure. We pooled 1018 population-based studies with blood pressure measurements on 88.6 million participants from 1985 to 2016. We first calculated mean systolic blood pressure (SBP), mean diastolic blood pressure (DBP) and prevalence of raised blood pressure by sex and 10-year age group from 20-29 years to 70-79 years in each study, taking into account complex survey design and survey sample weights, where relevant. We used a linear mixed effect model to quantify the association between (probit-transformed) prevalence of raised blood pressure and age-group- and sex-specific mean blood pressure. We calculated the contributions of change in mean SBP and DBP, and of change in the prevalence-mean association, to the change in prevalence of raised blood pressure. In 2005-16, at the same level of population mean SBP and DBP, men and women in South Asia and in Central Asia, the Middle East and North Africa would have the highest prevalence of raised blood pressure, and men and women in the high-income Asia Pacific and high-income Western regions would have the lowest. In most region-sex-age groups where the prevalence of raised blood pressure declined, one half or more of the decline was due to the decline in mean blood pressure. Where prevalence of raised blood pressure has increased, the change was entirely driven by increasing mean blood pressure, offset partly by the change in the prevalence-mean association. Change in mean blood pressure is the main driver of the worldwide change in

  19. Ambulatory blood pressure monitoring in daily clinical practice - the Spanish ABPM Registry experience.

    Science.gov (United States)

    Gorostidi, Manuel; Banegas, José R; de la Sierra, Alejandro; Vinyoles, Ernest; Segura, Julián; Ruilope, Luis M

    2016-01-01

    Many patients are hypertensive at the medical settings but show normal blood pressure out of the doctor's office, and are classified as white-coat hypertensives. On the other hand, many patients with controlled hypertension at the clinic show ambulatory blood pressure levels above the thresholds considered for an adequate blood pressure control, known as having masked hypertension. Using data from the Spanish Ambulatory Blood Pressure Monitoring Registry (Spanish ABPM Registry), a national program developed to promote the use of the ambulatory technique for hypertension management in daily practice, we have reviewed the main strengths of this approach, that is the ability to detect discrepancies of blood pressure status with respect to office blood pressure measurement, and to better assess accurate rates of hypertension control. White-coat hypertension within patients with elevated office blood pressure, and masked hypertension within office-controlled patients affected one of three patients in each office status. On the other hand, rates of ambulatory blood pressure control (50%) doubled those of office blood pressure control (25%), still remaining half the patients uncontrolled. We think that a systematic use of ambulatory blood pressure monitoring, and strategies to improve blood pressure control constitute key priorities in hypertension management. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  20. [Ambulatory blood pressure monitoring (ABPM) in elderly].

    Science.gov (United States)

    Palade, D; Iliescu, D; Cotârleţ, Laura; Pandele, G I

    2010-01-01

    Comparison of blood pressure values measured by two methods. 94 hypertensive patients (66 women and 28 men in relation to 2.36/1) were assessed classically and also by ABPM. For statistic evaluation we have used t - Student test, chi2 test, Pearson correlation coefficient and variation coefficient (cv%). It shows significant differences between mean values of systolic and diastolic blood pressure obtained by the 2 methods. ABPM measured values are more accurate compared to clinic, bringing also information on pattern hypertensive therapy.

  1. Noninvasive Intracranial Pressure and Tissue Oxygen Measurements for Space and Earth

    Science.gov (United States)

    Hargens, A. R.; Ballard, R. E.; Murthy, G.; Watenpaugh, D. E.

    1994-01-01

    The paper discusses the following: Increasing intracranial pressure in humans during simulated microgravity. and near-infrared monitoring of model chronic compartment syndrome in exercising skeletal muscle. Compared to upright-seated posture, 0 deg. supine, 6 deg. HDT, and 15 deg. HDT produced TMD changes of 317 +/- 112, 403 +/- 114, and 474 +/- 112 n1 (means +/- S.E.), respectively. Furthermore, postural transitions from 0 deg. supine to 6 deg. HDT and from 6 deg. to 15 deg. HDT generated significant TMD changes (p less than 0.05). There was no hysteresis when postural transitions to HDT were compared to reciprocal transitions toward upright seated posture. Currently, diagnosis of chronic compartment syndrome (CCS) depends on measurement of intramuscular pressure by invasive catheterization. We hypothesized that this syndrome can be detected noninvasively by near-infrared (NIR) spectroscopy, which tracks variations in muscle hemoglobin/myoglobin oxygen saturation. CCS was simulated in the tibialis anterior muscle of 7 male and 3 female subjects by gradual inflation of a cuff placed around the leg to 40 mmHg during 14 minutes of cyclic isokinetic dorsiflexion exercise. On a separate day, subjects underwent the identical exercise protocol with no external compression. In both cases, tissue oxygenation (T(sub O2) was measured in the tibialis anterior by NIR spectroscopy and normalized to a percentage scale between baseline and a T(sub O2) nadir reached during exercise to ischemic exhaustion. Over the course of exercise, T(sub O2) declined at a rate of 1.4 +/- 0.3% per minute with model CCS, yet did not decrease during control exercise. Post-exercise recovery of T(sub O2) was slower with model CCS (2.5 +/- 0.6 min) than in control (1.3 +/- 0.2 min). These results demonstrate that NIR spectroscopy can detect muscle deoxygenation caused by pathologically elevated intramuscular pressure in exercising skeletal muscle. Consequently, this technique shows promise as a

  2. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows

    Science.gov (United States)

    Nobre, Fernando; Mion Junior, Décio

    2016-01-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  3. Blood pressure among the Inuit (Eskimo) populations in the Arctic

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Dewailly, Eric; Young, T Kue

    2003-01-01

    Studies of blood pressure among various Inuit (Eskimo) populations in the Arctic have given inconsistent results. Most studies reported lower blood pressure among the Inuit as compared with the predominantly white national populations. This has been attributed to traditional subsistence practices...... and lifestyle. This study compared the blood pressure among the major Inuit population groups with other populations and examined the associations with factors like age, gender, obesity and smoking....

  4. Potentiation by aminopeptidase P of blood pressure response to bradykinin.

    OpenAIRE

    Kitamura, S; Carbini, L A; Carretero, O A; Simmons, W H; Scicli, A G

    1995-01-01

    We examined whether a specific aminopeptidase P (APP) inhibitor, apstatin, increases vasodepressor responses to bradykinin in anaesthetized rats, and whether it would augment blood pressure responses further after treatment with the angiotensin-converting enzyme inhibitor (ACEi), lisinopril. Apstatin doubled the maximum blood pressure response to bradykinin. The area under the curve (AUC), which incorporates both peak blood pressure changes and duration of response, was doubled in apstatin-tr...

  5. Impact of calibration on estimates of central blood pressures.

    Science.gov (United States)

    Soender, T K; Van Bortel, L M; Møller, J E; Lambrechtsen, J; Hangaard, J; Egstrup, K

    2012-12-01

    Using the Sphygmocor device it is recommended that the radial pressure wave is calibrated for brachial systolic blood pressure (SBP) and diastolic blood pressure (DBP). However it has been suggested that brachial-to-radial pressure amplification causes underestimation of central blood pressures (BPs) using this calibration. In the present study we examined if different calibrations had an impact on estimates of central BPs and on the clinical interpretation of our results. On the basis of ambulatory BP measurements, patients were categorized into patients with controlled, uncontrolled or resistant hypertension. We first calibrated the radial pressure wave as recommended and afterwards recalibrated the same pressure wave using brachial DBP and calculated mean arterial pressure. Recalibration of the pressure wave generated significantly higher estimates of central SBP (P=0.0003 and Plost in patients with resistant hypertension (P=0.15). We conclude that calibration with DBP and mean arterial pressure produces higher estimates of central BPs than recommended calibration. The present study also shows that this difference between the two calibration methods can produce more than a systematic error and has an impact on interpretation of clinical results.

  6. [Design of blood-pressure parameter auto-acquisition circuit].

    Science.gov (United States)

    Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A

    2000-02-01

    This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.

  7. Influence of sleep apnea severity on blood pressure variability of patients with hypertension.

    Science.gov (United States)

    Steinhorst, Ana P; Gonçalves, Sandro C; Oliveira, Ana T; Massierer, Daniela; Gus, Miguel; Fuchs, Sandra C; Moreira, Leila B; Martinez, Denis; Fuchs, Flávio D

    2014-05-01

    Obstructive sleep apnea (OSA) is a risk factor for the development of hypertension and cardiovascular disease. Apnea overloads the autonomic cardiovascular control system and may influence blood pressure variability, a risk for vascular damage independent of blood pressure levels. This study investigates the hypothesis that blood pressure variability is associated with OSA. In a cross-sectional study, 107 patients with hypertension underwent 24-h ambulatory blood pressure monitoring and level III polysomnography to detect sleep apnea. Pressure variability was assessed by the first derivative of blood pressure over time, the time rate index, and by the standard deviation of blood pressure measurements. The association between the apnea-hypopnea index and blood pressure variability was tested by univariate and multivariate methods. The 57 patients with apnea were older, had higher blood pressure, and had longer duration of hypertension than the 50 patients without apnea. Patients with apnea-hypopnea index (AHI) ≥ 10 had higher blood pressure variability assessed by the standard deviation than patients with AHI variability assessed by the time rate index presented a trend for association during sleep (P = 0.07). Daytime blood pressure variability was not associated with the severity of sleep apnea. Sleep apnea increases nighttime blood pressure variability in patients with hypertension and may be another pathway linking sleep abnormalities to cardiovascular disease.

  8. ASSOCIATION OF DAIRY CONSUMPTION AND 24-HOUR BLOOD PRESSURE IN OLDER ADULTS WITH HYPERTENSION.

    Science.gov (United States)

    Lana, Alberto; Banegas, Jose R; Guallar-Castillón, Pilar; Rodríguez-Artalejo, Fernando; Lopez-Garcia, Esther

    2018-05-25

    The aim was to examine the association between habitual consumption of dairy products and 24-h ambulatory blood pressure monitoring among older adults with hypertension. We conducted an analysis of 715 community-living hypertensive adults aged ≥60. Habitual dairy consumption was assessed with a validated diet history. Blood pressure was recorded by 24-hour ambulatory blood pressure monitoring; controlled blood pressure was defined as 24-hour blood pressure blood pressure 1.40 mm Hg higher (95% confidence interval: 0.01, 2.81) than consumers of blood pressure 1.74 mm Hg lower (95% confidence interval: -3.26, -0.23) than consumers of blood pressure was 1.83 (1.05-3.08) for those consuming ≥7 servings/wk of low-fat milk/yogurt, when comparing with consumers of blood pressure. Regular consumption of low-fat milk/yogurt was associated with lower 24-h diastolic blood pressure and with better blood pressure control among older adults with hypertension. Copyright © 2018. Published by Elsevier Inc.

  9. Potential benefits of exercise on blood pressure and vascular function.

    Science.gov (United States)

    Pal, Sebely; Radavelli-Bagatini, Simone; Ho, Suleen

    2013-01-01

    Physical activity seems to enhance cardiovascular fitness during the course of the lifecycle, improve blood pressure, and is associated with decreased prevalence of hypertension and coronary heart disease. It may also delay or prevent age-related increases in arterial stiffness. It is unclear if specific exercise types (aerobic, resistance, or combination) have a better effect on blood pressure and vascular function. This review was written based on previous original articles, systematic reviews, and meta-analyses indexed on PubMed from years 1975 to 2012 to identify studies on different types of exercise and the associations or effects on blood pressure and vascular function. In summary, aerobic exercise (30 to 40 minutes of training at 60% to 85% of predicted maximal heart rate, most days of the week) appears to significantly improve blood pressure and reduce augmentation index. Resistance training (three to four sets of eight to 12 repetitions at 10 repetition maximum, 3 days a week) appears to significantly improve blood pressure, whereas combination exercise training (15 minutes of aerobic and 15 minutes of resistance, 5 days a week) is beneficial to vascular function, but at a lower scale. Aerobic exercise seems to better benefit blood pressure and vascular function. Copyright © 2013 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  10. Pressure support ventilation vs Continuous positive airway pressure for treating of acute cardiogenic pulmonary edema: A pilot study.

    Science.gov (United States)

    Pagano, Antonio; Numis, Fabio G; Rosato, Valerio; Russo, Teresa; Porta, Giovanni; Bosso, Giorgio; Serra, Claudia; Masarone, Mario; Visone, Giuseppe; Paladino, Fiorella

    2018-04-24

    Non-invasive ventilation is usually adopted as a support to medical therapy in patients with acute pulmonary edema, but which modality between Pressure Support Ventilation (PSV) and Continuous Positive Airway Pressure (CPAP) has better favourable effects is not been yet well known. Aim of this observational study was to provide data on these different non-invasive ventilation modalities in the management of acute cardiogenic pulmonary edema. One-hundred-fifty-three patients consecutively admitted to the Emergency Room of two different Center were enrolled and randomly assigned to CPAP or PSV. Data relative to mortality, need of endotracheal intubation, sequential blood gas analysis were compared. Furthermore, there were no significant differences regarding mortality in the two groups, but patients treated with PSV had a significant lower rate of endotracheal intubation and a higher improvement of blood gas analyses parameters. In conclusion, our data support only a slight advantage in favour to PSV versus CPAP. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Nursing Education in High Blood Pressure Control. Report of the Task Force on the Role of Nursing in High Blood Pressure Control.

    Science.gov (United States)

    National Institutes of Health (DHEW), Bethesda, MD. High Blood Pressure Information Center.

    This curriculum guide on high blood pressure (hypertension) for nursing educators has five sections: (1) Introduction and Objectives provides information regarding the establishment and objectives of the National Task Force on the Role of Nursing in High Blood Pressure Control and briefly discusses nursing's role in hypertension control; (2) Goals…

  12. The effect of text messaging on hospital visits and blood pressure ...

    African Journals Online (AJOL)

    Background: Non-attendance to hospital appointment and non-adherence to blood pressure lowering medication are major factors in sub-optimal control of high blood pressure. The aim of the study was to assess the effect of text messaging on improving hospital visits and blood pressure control in adult hypertensives in ...

  13. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  14. Blood pressure and heart rate adjustment following acute Frenkel's ...

    African Journals Online (AJOL)

    Background: Frenkel's ambulatory activity has been routinely employed by physiotherapists for rehabilitation of gait coordination, however, its immediate influence on blood pressure and heart rate has not been investigated. Objective: To investigate the acute effect of Frenkel's ambulatory activity on blood pressure and ...

  15. Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types

    OpenAIRE

    Krisnarta Sembiring; Oke Rina Ramayani; Munar Lubis

    2018-01-01

    BACKGROUND: Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. OBJECTIVE: To determine the difference in mean blood pressure among adolescents based on dyssomnia types. METHODS: a Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep...

  16. Predictive role of the nighttime blood pressure

    DEFF Research Database (Denmark)

    Hansen, Tine W; Li, Yan; Boggia, José

    2011-01-01

    Numerous studies addressed the predictive value of the nighttime blood pressure (BP) as captured by ambulatory monitoring. However, arbitrary cutoff limits in dichotomized analyses of continuous variables, data dredging across selected subgroups, extrapolation of cross-sectional studies...... of conclusive evidence proving that nondipping is a reversible risk factor, the option whether or not to restore the diurnal blood pressure profile to a normal pattern should be left to the clinical judgment of doctors and should be individualized for each patient. Current guidelines on the interpretation...

  17. Endurance training in mild hypertension - effects on ambulatory blood pressure and neural circulatory control.

    Science.gov (United States)

    Narkiewicz; Somers

    1997-10-01

    This review examines the effects of a single bout of exercise and of endurance training on blood pressure in patients with hypertension. Possible autonomic mechanisms that mediate these changes in blood pressure are reviewed briefly. Blood pressure rises during exercise. During the second half hour after exercise blood pressure is lower. This p;ost-exercise reduction in blood pressure is associated with a decrease in muscle sympathetic nerve activity, an increase in baroreflex gain and a reduction in the level of blood pressure (set point) at which baroreflex activation occurs. The post-exercise fall in blood pressure appears to be limited to several hours and is not likely to explain any chronic reduction in blood pressure from endurance training. Endurance training elicits modest (approximately 4-5 mmHg) reductions in blood pressure. Because of the intrinsic variability of blood pressure, the decreases in blood pressure after endurance training is evident, especially when multiple measurements of blood pressure are obtained. Studies using 24 h blood pressure measurements suggest that, although endurance training lowers daytime blood pressure, blood pressure during sleep remains unchanged. The mechanism underlying the reduction in blood pressure in endurance training is not known. Although physical fitness is known to attenuate the sympathetic response to acute exercise, whether resting sympathetic drive is decreased with endurance training remains controversial. The slowing of heart rate that accompanies endurance training is also associated with an increase in variability of heart rate. The slower heart rate, increased variability of heart rate and lower blood pressure after endurance training are accompanied by an increase in baroreflex sensitivity. Even though the antihypertensive effect of endurance training is modest, the favourable effects of physical fitness on other risk factors for cardiovascular disease make exercise training an important approach in

  18. Data Of Daily Blood Pressure Monitoring In Patients With Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    A.P. Rebrov

    2009-06-01

    Full Text Available The aim of present work is to study the frequency of hypertension and the peculiarity of 24-hour blood pressure monitoring in patients with rheumatoid arthritis. We studied 584 patients with rheumatoid arthritis. Daily blood pressure monitoring was carried out in 46 patients with arthritis and 18 patients with essential hypertension. Frequency of hypertension was higher in patients with arthritis then in general population. Elevation of systolic blood pressure, heart rate and arterial blood pressure adequate decrease at night were developed to associate with advance of the disease.

  19. The effect of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome

    Directory of Open Access Journals (Sweden)

    Giorgiana Dediu

    2017-12-01

    Full Text Available Introduction. Obstructive sleep apnea syndrome (OSAS is a disease with increasing prevalence nowadays, being associated with multiple cardiovascular diseases, such as arterial hypertension. The objective of the study was to evaluate the effect of continuous positive airway pressure (CPAP on blood pressure values. Materials and methods. We performed a prospective interventional study on 52 patients with obstructive sleep apnea syndrome. The patients were divided into 2 groups: Group A (who received both pharmacological and CPAP treatment and Group B (who received only pharmacological treatment, and were followed up at 3 and 6 months. The statistical analysis was made with SPSS and Microsoft Excel. At the same time, using the surrogate marker –RDW, we tried to evaluate the persistence of systemic inflammation, knowing that OSAS is associated with inflammation. Results. The systolic blood pressure values decreased at 6 months in all OSAS patients who have used CPAP, including patients with normal values of blood pressure. At the same time, the lack of OSAS treatment led to increased values of blood pressure by approximately 10 mmHg. We noticed a link between RDW, age and blood pressure values, respectively the increase of RDW and age may result in an increase in blood pressure. Conclusions. The OSAS treatment can decrease the blood pressure values. A higher RDW may be considered a negative prognostic factor for these patients, reflecting the role of systemic inflammation in the appearance of cardiovascular disorders.

  20. Surgical treatment reduces blood pressure in children with unilateral congenital hydronephrosis.

    Science.gov (United States)

    Al-Mashhadi, Ammar; Nevéus, Tryggve; Stenberg, Arne; Karanikas, Birgitta; Persson, A Erik G; Carlström, Mattias; Wåhlin, Nils

    2015-04-01

    Renal disorders can cause hypertension, but less is known about the influence of hydronephrosis on blood pressure. Hydronephrosis due to pelvo-ureteric junction obstruction (PUJO) is a fairly common condition (incidence in newborns of 0.5-1%). Although hypertensive effects of hydronephrosis have been suggested, this has not been substantiated by prospective studies in humans [1-3]. Experimental studies with PUJO have shown that animals with induced hydronephrosis develop salt-sensitive hypertension, which strongly correlate to the degree of obstruction [4-7]. Moreover, relief of the obstruction normalized blood pressure [8]. In this first prospective study our aim was to study the blood pressure pattern in pediatric patients with hydronephrosis before and after surgical correction of the ureteral obstruction. Specifically, we investigated if preoperative blood pressure is reduced after surgery and if split renal function and renographic excretion curves provide any prognostic information. Twelve patients with unilateral congenital hydronephrosis were included in this prospective study. Ambulatory blood pressure (24 h) was measured preoperatively and six months after surgery. Preoperative evaluations of bilateral renal function by Tc99m-MAG3 scintigraphy, and renography curves, classified according to O'Reilly, were also performed. As shown in the summary figure, postoperative systolic (103 ± 2 mmHg) and diastolic (62 ± 2 mmHg) blood pressure were significantly lower than those obtained preoperatively (110 ± 4 and 69 ± 2 mmHg, respectively), whereas no changes in circadian variation or pulse pressure were observed. Renal functional share of the hydronephrotic kidney ranged from 11 to 55%. There was no correlation between the degree of renal function impairment and the preoperative excretory pattern, or between the preoperative excretory pattern and the blood pressure reduction postoperatively. However, preoperative MAG3 function of the affected kidney correlated

  1. Seaweed intake and blood pressure levels in healthy pre-school Japanese children

    Directory of Open Access Journals (Sweden)

    Yamamoto Keiko

    2011-08-01

    Full Text Available Abstract Background Few studies have examined whether dietary factors might affect blood pressure in children. We purposed to investigate whether seaweed intake is associated with blood pressure level among Japanese preschool children. Methods The design of the study was cross-sectional and it was conducted in autumn 2006. Subjects were healthy preschoolers aged 3-6 years in Aichi, Japan. Blood pressure and pulse were measured once by an automated sphygmomanometer, which uses oscillometric methods. Dietary data, including seaweed intake, were assessed using 3-day dietary records covering 2 consecutive weekdays and 1 weekend day. Of a total of 533 children, 459 (86.1 percent agreed to be enrolled in our study. Finally, blood pressure measurement, complete dietary records and parent-reported height and weight were obtained for 223 boys and 194 girls. Results When we examined Spearman's correlation coefficients, seaweed intake was significantly negatively related to systolic blood pressure in girls (P = 0.008. In the one-way analysis of covariance for blood pressure and pulse after adjustments for age and BMI, the boys with the lowest, middle and highest tertiles of seaweed intake had diastolic blood pressure readings of 62.8, 59.3 and 59.6 mmHg, respectively (P = 0.11, trend P = 0.038. Girls with higher seaweed intake had significantly lower systolic blood pressure readings (102.4, 99.2 and 96.9 mmHg for girls with the lowest, middle and highest tertiles of seaweed intake, respectively; P = 0.037, trend P = 0.030. Conclusion Our study showed that seaweed intake was negatively related to diastolic blood pressure in boys and to systolic blood pressure in girls. This suggests that seaweed might have beneficial effects on blood pressure among children.

  2. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  3. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  4. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  5. Which Target Blood Pressure in Year 2018? Evidence from Recent Clinical Trials.

    Science.gov (United States)

    Heimark, Sondre; Mariampillai, Julian E; Narkiewicz, Krzysztof; Nilsson, Peter M; Kjeldsen, Sverre E

    2018-04-16

    The Systolic Blood Pressure Intervention Trial (SPRINT) suggested a favourable effect of lowering blood pressure to Blood Pressure (ACCORD) study, the International Verapamil-Trandolapril Study (INVEST), the Telmisartan, Ramipril or Both in Patients at High Risk for Vascular Events trial (ONTARGET)/the Telmisartan Randomised AssessmenNt Study in aCE iNtolerant participants with cardiovascular Disease (TRANSCEND) study and The Losartan Intervention For Endpoint Reduction in Hypertension (LIFE) study. These studies confirm a positive effect on cardiovascular protection with blood pressure lowering treatment to between 120-140 mmHg in patients with and without diabetes, but no additional effect of lowering blood pressure to blood pressure < 130/80 mmHg appears appropriate in most high-risk hypertensive patients. Additionally, early and sustained BP control below this target is required for optimal cardiovascular protection.

  6. Blood pressure patterns in women with gestational hypertension or mild preeclampsia at term.

    Science.gov (United States)

    van der Tuuk, K; Tajik, P; Koopmans, C M; van den Berg, P P; Mol, B W J; van Pampus, M G; Groen, H

    2017-03-01

    Gestational hypertension (GH) and mild preeclampsia (PE) represent the most common medical complications of pregnancy, with the majority of cases developing at or near term. There is little knowledge of the course of blood pressure over time in these women. We explored the pattern of systolic and diastolic blood pressure over time in women with GH or mild PE at term participating in the HYPITAT trial, and we attempted to identify clinical factors influencing these blood pressure patterns and the impact of severe hypertension on clinical management. We used data from the HYPITAT trial, that included women with a singleton pregnancy with a fetus in cephalic position between 36 and 41 weeks of gestation with the diagnosis of GH or mild PE. Blood pressure measurements were performed from randomization or admission until delivery or discharge from the hospital. We included the highest blood pressure of each day. We evaluated systolic and diastolic blood pressure change over time, as well as the influence of clinical characteristics and laboratory findings on the course of blood pressure. We used univariate and multivariate regression analysis with a backward stepwise algorithm for the selection of variables. The model with the best fit (lowest AIC) was selected as the final model. We also compared mode of delivery for women with and without severe hypertension. We studied 1076 women who had 4188 blood pressure measurements done. The systolic blood pressure showed a significant non-linear increase over time and for the diastolic blood pressure the pattern was also non-linear. In the multivariable model of systolic blood pressure change over time, nulliparity, ethnicity, systolic blood pressure (at baseline), BMI and LDH at randomization influenced the course of blood pressure. In the diastolic blood pressure model ALT and the baseline diastolic blood pressure had a significant influence. When we explored the association between blood pressure and mode of delivery, it

  7. Arterial Pressure Gradients during Upright Posture and 30 deg Head Down Tilt

    Science.gov (United States)

    Sanchez, E. R; William, J. M.; Ueno, T.; Ballard, R. E.; Hargens, A. R.; Holton, Emily M. (Technical Monitor)

    1997-01-01

    Gravity alters local blood pressure within the body so that arterial pressures in the head and foot are lower and higher, respectively, than that at heart level. Furthermore, vascular responses to local alterations of arterial pressure are probably important to maintain orthostatic tolerance upon return to the Earth after space flight. However, it has been difficult to evaluate the body's arterial pressure gradient due to the lack of noninvasive technology. This study was therefore designed to investigate whether finger arterial pressure (FAP), measured noninvasively, follows a normal hydrostatic pressure gradient above and below heart level during upright posture and 30 deg head down tilt (HDT). Seven healthy subjects gave informed consent and were 19 to 52 years old with a height range of 158 to 181 cm. A Finapres device measured arterial pressure at different levels of the body by moving the hand from 36 cm below heart level (BH) to 72 cm above heart level (AH) in upright posture and from 36 cm BH to 48 cm AH during HDT in increments of 12 cm. Mean FAP creased by 85 mmHg transitioning from BH to AH in upright posture, and the pressure gradient calculated from hydrostatic pressure difference (rho(gh)) was 84 mmHg. In HDT, mean FAP decreased by 65 mmHg from BH to AH, and the calculated pressure gradient was also 65 mmHg. There was no significant difference between the measured FAP gradient and the calculated pressure gradient, although a significant (p = 0.023) offset was seen for absolute arterial pressure in upright posture. These results indicate that arterial pressure at various levels can be obtained from the blood pressure at heart level by calculating rho(gh) + an offset. The offset equals the difference between heart level and the site of measurement. In summary, we conclude that local blood pressure gradients can be measured by noninvasive studies of FAP.

  8. Renal intercalated cells and blood pressure regulation

    Directory of Open Access Journals (Sweden)

    Susan M. Wall

    2017-12-01

    Full Text Available Type B and non-A, non-B intercalated cells are found within the connecting tubule and the cortical collecting duct. Of these cell types, type B intercalated cells are known to mediate Cl⁻ absorption and HCO₃⁻ secretion largely through pendrin-dependent Cl⁻/HCO₃⁻ exchange. This exchange is stimulated by angiotensin II administration and is also stimulated in models of metabolic alkalosis, for instance after aldosterone or NaHCO₃ administration. In some rodent models, pendrin-mediated HCO₃⁻ secretion modulates acid-base balance. However, the role of pendrin in blood pressure regulation is likely of more physiological or clinical significance. Pendrin regulates blood pressure not only by mediating aldosterone-sensitive Cl⁻ absorption, but also by modulating the aldosterone response for epithelial Na⁺ channel (ENaC-mediated Na⁺ absorption. Pendrin regulates ENaC through changes in open channel of probability, channel surface density, and channels subunit total protein abundance. Thus, aldosterone stimulates ENaC activity through both direct and indirect effects, the latter occurring through its stimulation of pendrin expression and function. Therefore, pendrin contributes to the aldosterone pressor response. Pendrin may also modulate blood pressure in part through its action in the adrenal medulla, where it modulates the release of catecholamines, or through an indirect effect on vascular contractile force. This review describes how aldosterone and angiotensin II-induced signaling regulate pendrin and the contributory role of pendrin in distal nephron function and blood pressure.

  9. Pediatric Blood Pressure and Adult Preclinical Markers of Cardiovascular Disease

    Science.gov (United States)

    Magnussen, Costan G.; Smith, Kylie J.

    2016-01-01

    A high blood pressure level in adults is considered the single most important modifiable risk factor for global disease burden, especially those of cardiovascular (CV) origin such as stroke and ischemic heart disease. Because blood pressure levels have been shown to persist from childhood to adulthood, elevations in pediatric levels have been hypothesized to lead to increased CV burden in adulthood and, as such, might provide a window in the life course where primordial and primary prevention could be focused. In the absence of substantive data directly linking childhood blood pressure levels to overt adult CV disease, this review outlines the available literature that examines the association between pediatric blood pressure and adult preclinical markers of CV disease. PMID:27168729

  10. Pulse pressure and diabetes treatments: Blood pressure and pulse pressure difference among glucose lowering modality groups in type 2 diabetes.

    Science.gov (United States)

    Alemi, Hamid; Khaloo, Pegah; Mansournia, Mohammad Ali; Rabizadeh, Soghra; Salehi, Salome Sadat; Mirmiranpour, Hossein; Meftah, Neda; Esteghamati, Alireza; Nakhjavani, Manouchehr

    2018-02-01

    Type 2 diabetes is associated with higher pulse pressure. In this study, we assessed and compared effects of classic diabetes treatments on pulse pressure (PP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) in patients with type 2 diabetes.In a retrospective cohort study, 718 non-hypertensive patients with type 2 diabetes were selected and divided into 4 groups including metformin, insulin, glibenclamide+metformin, and metformin+insulin. They were followed for 4 consecutive visits lasting about 45.5 months. Effects of drug regimens on pulse and blood pressure over time were assessed separately and compared in regression models with generalized estimating equation method and were adjusted for age, duration of diabetes, sex, smoking, and body mass index (BMI).Studied groups had no significant change in PP, SBP, and DBP over time. No significant difference in PP and DBP among studied groups was observed (PP:P = 0.090; DBP:P = 0.063). Pairwise comparisons of PP, SBP, and DBP showed no statistically significant contrast between any 2 studied groups. Interactions of time and treatment were not different among groups.Our results demonstrate patients using metformin got higher PP and SBP over time. Averagely, pulse and blood pressure among groups were not different. Trends of variation in pulse and blood pressure were not different among studied diabetes treatments.

  11. A Nutritional Strategy for the Treatment of High Blood Pressure.

    Science.gov (United States)

    Podell, Richard N.

    1984-01-01

    Some physicians wonder if high blood pressure can be controlled without the use of drugs and their potential side effects. Current findings concerning nutrition and high blood pressure are presented. (RM)

  12. Home readings of blood pressure in assessment of hypertensive subjects

    DEFF Research Database (Denmark)

    Nielsen, P.E.; Myschetzky, P; Andersen, A R

    1986-01-01

    Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self......-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter...

  13. Weightlifting: Bad for Your Blood Pressure?

    Science.gov (United States)

    ... individuals. American Journal of Physiology. Heart and Circulatory Physiology. 2016;311:H1024. Carlson DJ, et al. Isometric exercise training for blood pressure management: A systematic review ...

  14. Effect of fenofibrate on blood pressure reduction

    Directory of Open Access Journals (Sweden)

    A K Lipatenkova

    2013-03-01

    Full Text Available Реферат по материалам статей 1. Gilbert K, Nian H, Yu C, Luther JM, Brown NJ. Fenofibrate lowers blood pressure in salt-sensitive but not salt-resistant hypertension. J Hypertens. 2013 Apr;31(4:820-9. doi: 10.1097/HJH.0b013e32835e8227. 2. Kwang K. K. Does Fenofibrate Lower Blood Pressure? Hypertension. 2013 Mar;61(3:e27. doi: 10.1161/HYPERTENSIONAHA.111.00792.

  15. Chronic Tea Consumption Lowers Blood Pressure in Rats: Some ...

    African Journals Online (AJOL)

    Chronic Tea Consumption Lowers Blood Pressure in Rats: Some Associated Mechanisms. ... Nigerian Journal of Health and Biomedical Sciences ... In experiment 5, group 9 (kept on NF and indomethacin solution) also had similar BP as group 10 (kept on ... KEY WORDS: Blood pressure (BP), heart rate (HR), rats, tea.

  16. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  17. Effect of Hibiscus sabdariffa on Blood Pressure and Electrolyte ...

    African Journals Online (AJOL)

    Effect of Hibiscus sabdariffa on Blood Pressure and Electrolyte Profile of Mild to Moderate Hypertensive Nigerians: A Comparative Study with Hydrochlorothiazide. ... Aim: The aim of this study is to investigate the effect of HS consumption on blood pressure (BP) and electrolytes of mild to moderate hypertensive Nigerians ...

  18. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  19. Influence of Baseline Diastolic Blood Pressure on Effects of Intensive Compared With Standard Blood Pressure Control.

    Science.gov (United States)

    Beddhu, Srinivasan; Chertow, Glenn M; Cheung, Alfred K; Cushman, William C; Rahman, Mahboob; Greene, Tom; Wei, Guo; Campbell, Ruth C; Conroy, Margaret; Freedman, Barry I; Haley, William; Horwitz, Edward; Kitzman, Dalane; Lash, James; Papademetriou, Vasilios; Pisoni, Roberto; Riessen, Erik; Rosendorff, Clive; Watnick, Suzanne G; Whittle, Jeffrey; Whelton, Paul K

    2018-01-09

    In individuals with a low diastolic blood pressure (DBP), the potential benefits or risks of intensive systolic blood pressure (SBP) lowering are unclear. SPRINT (Systolic Blood Pressure Intervention Trial) was a randomized controlled trial that compared the effects of intensive (target baseline DBP. Mean baseline SBP and DBP were 139.7±15.6 and 78.1±11.9 mm Hg, respectively. Regardless of the randomized treatment, baseline DBP had a U-shaped association with the hazard of the primary cardiovascular disease outcome. However, the effects of the intensive SBP intervention on the primary outcome were not influenced by baseline DBP level ( P for interaction=0.83). The primary outcome hazard ratio for intensive versus standard treatment was 0.78 (95% confidence interval, 0.57-1.07) in the lowest DBP quintile (mean baseline DBP, 61±5 mm Hg) and 0.74 (95% confidence interval, 0.61-0.90) in the upper 4 DBP quintiles (mean baseline DBP, 82±9 mm Hg), with an interaction P value of 0.78. Results were similar for all-cause death and kidney events. Low baseline DBP was associated with increased risk of cardiovascular disease events, but there was no evidence that the benefit of the intensive SBP lowering differed by baseline DBP. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01206062. © 2017 American Heart Association, Inc.

  20. 21 CFR 868.1200 - Indwelling blood oxygen partial pressure (PO2) analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indwelling blood oxygen partial pressure (PO2... Indwelling blood oxygen partial pressure (PO2) analyzer. (a) Identification. An indwelling blood oxygen... electrode) and that is used to measure, in vivo, the partial pressure of oxygen in blood to aid in...

  1. Family Adaptability and Cohesion and High Blood Pressure among Urban African American women

    Science.gov (United States)

    Brittain, Kelly; Taylor, Jacquelyn Y.; Wu, Chun Yi

    2010-01-01

    African American women are at greater risk for complications related to high blood pressure. This study examined relationships between high blood pressure, pulse pressure, body mass index, family adaptability, family cohesion and social support among 146 Urban African American women. Significant relationships were found between family adaptability and systolic blood pressure (p = .03) and between adaptability and pulse pressure (p ≤ .01). Based on study results, practitioners should routinely assess family functioning, specifically family adaptability, in African American women who are at risk for high blood pressure or diagnosed with high blood pressure to minimize complications associated with hypertension. PMID:21076625

  2. Relationship of central and peripheral blood pressure to left ventricular mass in hypertensive patients.

    Science.gov (United States)

    Pérez-Lahiguera, Francisco J; Rodilla, Enrique; Costa, Jose A; Gonzalez, Carmen; Martín, Joaquin; Pascual, Jose M

    2012-12-01

    The purpose of the present study was to assess the relationship of central and peripheral blood pressure to left ventricular mass. Cross-sectional study that included 392 never treated hypertensive individuals. Measurement of office, 24-h ambulatory, and central blood pressure (obtained using applanation tonometry) and determination of left ventricular mass by echocardiography were performed in all patients. In a multiple regression analysis, with adjustment for age, gender and metabolic syndrome, 24-h blood pressure was more closely related to ventricular mass than the respective office and central blood pressures. Systolic blood pressures always exhibited a higher correlation than diastolic blood pressures in all 3 determinations. The correlation between left ventricular mass index and 24-h systolic blood pressure was higher than that of office (P<.002) or central systolic blood pressures (P<.002). Changes in 24-h systolic blood pressure caused the greatest variations in left ventricular mass index (P<.001). In our population of untreated middle-aged hypertensive patients, left ventricular mass index is more closely related to 24-h ambulatory blood pressure than to office or central blood pressure. Central blood pressure does not enable us to better identify patients with left ventricular hypertrophy. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  3. [Unhealthy behavior associated with the development of high blood pressure in adolescents].

    Science.gov (United States)

    Sánchez-Zamorano, Luisa María; Burguete-García, Ana Isabel; Flores-Sánchez, Guillermo; Salmerón-Castro, Jorge; Lazcano-Ponce, Eduardo C; Diaz-Benitez, Cinthya E

    2017-04-03

    This article aims to evaluate the association between unhealthy behavior pattern and prevalence and incidence of high blood pressure in adolescents. Based on data from a cohort study with a baseline population of 2,813 adolescents enrolled in a public school system, the study measured the baseline prevalence and incidence of high blood pressure as a function of smoking, alcohol and illegal drug use, and physical activity. These variables were used to build a model called "unhealthy behavior pattern", and its relationship was evaluated in relation to high blood pressure in adolescents, using multiple logistic regression models. Prevalence of high blood pressure was 8.67%. Accumulated incidence of high blood pressure was 7.58%. In the multivariate analysis of high blood pressure adjusted by degree of adiposity, there was an association with the unhealthy behavior pattern in males (OR = 3.13; 95%CI: 1.67-5.84). The association between incidence of high blood pressure and unhealthy behavior pattern was observed in females (OR = 2.34; 95%CI: 1.11-4.95). In conclusion, high blood pressure is present in the adolescent population, associated with unhealthy behaviors like smoking, alcohol and illegal drug use, and physical inactivity, independently of the degree of adiposity.

  4. Longitudinal assessment of high blood pressure in children with nonalcoholic fatty liver disease.

    Science.gov (United States)

    Schwimmer, Jeffrey B; Zepeda, Anne; Newton, Kimberly P; Xanthakos, Stavra A; Behling, Cynthia; Hallinan, Erin K; Donithan, Michele; Tonascia, James

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) affects 9.6% of children and may put these children at elevated risk of high blood pressure and subsequent cardiovascular morbidity and mortality. Therefore, we sought to determine the prevalence of and risk factors for high blood pressure in children with NAFLD. Cohort study performed by the NIDDK NASH Clinical Research Network. There were 484 children with NAFLD ages 2 to 17 at enrollment; 382 children were assessed both at enrollment and 48 weeks afterwards. The main outcomes were high blood pressure at baseline and persistent high blood pressure at both baseline and 48 weeks. Prevalence of high blood pressure at baseline was 35.8% and prevalence of persistent high blood pressure was 21.4%. Children with high blood pressure were significantly more likely to have worse steatosis than children without high blood pressure (mild 19.8% vs. 34.2%, moderate 35.0% vs. 30.7%, severe 45.2% vs. 35.1%; P = 0.003). Higher body mass index, low-density lipoprotein, and uric acid were independent risk factors for high blood pressure (Odds Ratios: 1.10 per kg/m2, 1.09 per 10 mg/dL, 1.25 per mg/dL, respectively). Compared to boys, girls with NAFLD were significantly more likely to have persistent high blood pressure (28.4% vs.18.9%; P = 0.05). In conclusion, NAFLD is a common clinical problem that places children at substantial risk for high blood pressure, which may often go undiagnosed. Thus blood pressure evaluation, control, and monitoring should be an integral component of the clinical management of children with NAFLD.

  5. Longitudinal assessment of high blood pressure in children with nonalcoholic fatty liver disease.

    Directory of Open Access Journals (Sweden)

    Jeffrey B Schwimmer

    Full Text Available Nonalcoholic fatty liver disease (NAFLD affects 9.6% of children and may put these children at elevated risk of high blood pressure and subsequent cardiovascular morbidity and mortality. Therefore, we sought to determine the prevalence of and risk factors for high blood pressure in children with NAFLD.Cohort study performed by the NIDDK NASH Clinical Research Network. There were 484 children with NAFLD ages 2 to 17 at enrollment; 382 children were assessed both at enrollment and 48 weeks afterwards. The main outcomes were high blood pressure at baseline and persistent high blood pressure at both baseline and 48 weeks.Prevalence of high blood pressure at baseline was 35.8% and prevalence of persistent high blood pressure was 21.4%. Children with high blood pressure were significantly more likely to have worse steatosis than children without high blood pressure (mild 19.8% vs. 34.2%, moderate 35.0% vs. 30.7%, severe 45.2% vs. 35.1%; P = 0.003. Higher body mass index, low-density lipoprotein, and uric acid were independent risk factors for high blood pressure (Odds Ratios: 1.10 per kg/m2, 1.09 per 10 mg/dL, 1.25 per mg/dL, respectively. Compared to boys, girls with NAFLD were significantly more likely to have persistent high blood pressure (28.4% vs.18.9%; P = 0.05.In conclusion, NAFLD is a common clinical problem that places children at substantial risk for high blood pressure, which may often go undiagnosed. Thus blood pressure evaluation, control, and monitoring should be an integral component of the clinical management of children with NAFLD.

  6. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  7. The effect of fish oil supplements on blood pressure.

    Science.gov (United States)

    Lofgren, R P; Wilt, T J; Nichol, K L; Crespin, L; Pluhar, R; Eckfeldt, J

    1993-01-01

    We conducted a double-blind, placebo-controlled crossover study to determine the effects of fish oil supplementation on blood pressure in middle-aged men. Subjects were randomly assigned to consume either 20 g of fish oil or safflower oil for 12 weeks and then consume the other oil for an additional 12 weeks after a 4-week washout period. We found no significant changes from the pretreatment value in systolic or diastolic blood pressure with the use of fish oil supplements. In addition, there were no significant differences in the posttreatment blood pressures comparing the fish and safflower oil phases of the study. PMID:8427339

  8. Waist circumference as an indicator of high blood pressure in preschool obese children.

    Science.gov (United States)

    Chen, Bin; Li, Hai-fei

    2011-01-01

    To investigate the relationship between waist circumference and blood pressure (BP) to determine if waist circumference was an indicator of BP in preschool children. Body weight, height, waist circumference (WC), hip circumference, and blood pressure of 939 3-6-year-old preschool children were collected. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) in obese children were significantly higher than that in normal weight children in both sexes (phigh blood pressure in children of both sexes. Multiple linear stepwise regression analysis using SBP as the dependent variable showed that BMI and WC were significant independent factors that influence high blood pressure adjusted for age, WtHr and waist-to-hip circumference ratio (WHr) in boys. When using DBP as the dependent variable, BMI was the only significant independent factor that influenced high blood pressure adjusted for age, WtHr and WHr, in both sex-es. Waist circumference was independently associated with high blood pressure in boys aged 3-6 years. In addition to BMI, increased waist circumference was found to be an indicator of high blood pressure in the preschool children, especially in boys.

  9. What Physical Fitness Component Is Most Closely Associated With Adolescents' Blood Pressure?

    Science.gov (United States)

    Nunes, Heloyse E G; Alves, Carlos A S; Gonçalves, Eliane C A; Silva, Diego A S

    2017-12-01

    This study aimed to determine which of four selected physical fitness variables, would be most associated with blood pressure changes (systolic and diastolic) in a large sample of adolescents. This was a descriptive and cross-sectional, epidemiological study of 1,117 adolescents aged 14-19 years from southern Brazil. Systolic and diastolic blood pressure were measured by a digital pressure device, and the selected physical fitness variables were body composition (body mass index), flexibility (sit-and-reach test), muscle strength/resistance (manual dynamometer), and aerobic fitness (Modified Canadian Aerobic Fitness Test). Simple and multiple linear regression analyses revealed that aerobic fitness and muscle strength/resistance best explained variations in systolic blood pressure for boys (17.3% and 7.4% of variance) and girls (7.4% of variance). Aerobic fitness, body composition, and muscle strength/resistance are all important indicators of blood pressure control, but aerobic fitness was a stronger predictor of systolic blood pressure in boys and of diastolic blood pressure in both sexes.

  10. White-Coat Hypertension: When Blood Pressure Rises at the Doctor's Office

    Science.gov (United States)

    White coat hypertension: When blood pressure rises at the doctor's office My blood pressure is always higher in the ... You could have a condition known as white coat hypertension. White coat hypertension occurs when the blood ...

  11. The Relationship Between Preoperative and Primary Care Blood Pressure Among Veterans Presenting from Home for Surgery. Is There Evidence for Anesthesiologist-Initiated Blood Pressure Referral?

    Science.gov (United States)

    Schonberger, Robert B.; Burg, Matthew M.; Holt, Natalie; Lukens, Carrie L.; Dai, Feng; Brandt, Cynthia

    2011-01-01

    Background American College of Cardiology/American Heart Association guidelines describe the perioperative evaluation as “a unique opportunity to identify patients with hypertension,” however factors such as anticipatory stress or medication noncompliance may induce a bias toward higher blood pressure, leaving clinicians unsure about how to interpret preoperative hypertension. Information describing the relationship between preoperative intake blood pressure and primary care measurements could help anesthesiologists make primary care referrals for improved blood pressure control in an evidence-based fashion. We hypothesized that the preoperative examination provides a useful basis for initiating primary care blood pressure referral. Methods We analyzed retrospective data on 2807 patients who arrived from home for surgery and who were subsequently evaluated within 6 months after surgery in the primary care center of the same institution. After descriptive analysis, we conducted multiple linear regression analysis to identify day-of-surgery (DOS) factors associated with subsequent primary care blood pressure. We calculated the sensitivity, specificity, and positive and negative predictive value of different blood pressure referral thresholds using both a single-measurement and a two-stage screen incorporating recent preoperative and DOS measurements for identifying patients with subsequently elevated primary care blood pressure. Results DOS systolic blood pressure (SBP) was higher than subsequent primary care SBP by a mean bias of 5.5mmHg (95% limits of agreement +43.8 to −32.8). DOS diastolic blood pressure (DBP) was higher than subsequent primary care DBP by a mean bias of 1.5mmHg (95% limits of agreement +13.0 to −10.0). Linear regression of DOS factors explained 19% of the variability in primary care SBP and 29% of the variability in DBP. Accounting for the observed bias, a two-stage SBP referral screen requiring preoperative clinic SBP≥140mmHg and DOS

  12. Early Weight Gain, Linear Growth, and Mid-Childhood Blood Pressure

    DEFF Research Database (Denmark)

    Perng, Wei; Rifas-Shiman, Sheryl L; Kramer, Michael S

    2016-01-01

    of gains in body mass index z-score and length/height z-score during 4 early life age intervals (birth to 6 months, 6 months to 1 year, 1 to 2 years, and 2 to 3 years) with blood pressure during mid-childhood (6-10 years) and evaluated whether these relations differed by birth size. After accounting....... Strategies to reduce accrual of excess adiposity during early life may reduce mid-childhood blood pressure, which may also impact adult blood pressure and cardiovascular health....

  13. Non-hemodynamic predictors of blood pressure in recreational sport ...

    African Journals Online (AJOL)

    Currently, there are evidences that regular physical activity is an efficient means to control high blood pressure. This cross-sectional study aims at identifying in subjects who exercise in non-institutional structures at Cotonou, the main factors that account for the inter-individual variations of the blood pressure. Four adiposity ...

  14. Relationship between blood pressure, body mass index and health ...

    African Journals Online (AJOL)

    Objective: Globally, studies have shown that the trend of overweight and obesity has increased astronomically and there is a close link between body mass index and blood pressure. This study determined the link between the body mass index (BMI), blood pressure and health promoting practices of women in rural and ...

  15. Blood Pressure Abnormalities in Parkinson's Disease in a Nigerian ...

    African Journals Online (AJOL)

    To compare the effect of posture on blood pressure in levodopa-treated Parkinson's disease (PD) patients with that of age-matched controls. The design is a case control study. Blood pressure was recorded manually in the seated position with Accossons® mercury sphygmomanometer in 30 consecutive patients with PD on ...

  16. The Influence of Proximity to City Parks on Blood Pressure in Early Pregnancy

    Directory of Open Access Journals (Sweden)

    Regina Grazuleviciene

    2014-03-01

    Full Text Available This study investigated the effect of proximity to city parks on blood pressure categories during the first trimester of pregnancy. This cross-sectional study included 3,416 female residents of the city of Kaunas, Lithuania, who were enrolled in the FP7 PHENOTYPE project study. The women were classified into four blood pressure categories: optimal, normal, high-normal blood pressure, and hypertension. Multinomial regression models were used to investigate the association between three women’s groups with respect to the residence distances from city parks (300, >300–1,000, and >1,000 m and four blood pressure categories. When using the optimal blood pressure as the reference group, the crude and adjusted odds ratios (OR for normal blood pressure and for high-normal blood pressure proved to be statistically significantly higher after the inclusion of the selected covariates into the regression analysis. The probability of normal blood pressure increased by 9%, and that of high-normal blood pressure—by 14% for every 300 m increase in the distance to green spaces. The findings of this study suggest a beneficial impact of nearby city parks on blood pressure amongst 20- to 45-year-old women. This relationship has important implications for the prevention of hypertension and the reduction of hypertension-related morbidity.

  17. The association between smoking and blood pressure in men: a cross-sectional study.

    Science.gov (United States)

    Li, Guoju; Wang, Hailing; Wang, Ke; Wang, Wenrui; Dong, Fen; Qian, Yonggang; Gong, Haiying; Hui, Chunxia; Xu, Guodong; Li, Yanlong; Pan, Li; Zhang, Biao; Shan, Guangliang

    2017-10-10

    Cigarette smoking is a known risk factor for cardiovascular disease (CVD), but the association between smoking and blood pressure is unclear. Thus, the current study examined the association between cigarette smoking and blood pressure in men. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and pulse pressure (PP) were examined using digital blood pressure measuring device, and smoking status was determined with China National Health Survey. The ANCOVA showed that the adjusted DBP and MAP were lower in current smokers versus nonsmokers and the adjusted SBP was lower in current smokers versus former smokers (P smoking on blood pressure indices except PP was observed. Smoking cessation was significantly associated with an increased risk of hypertension. However, current smoking was not a risk factor of hypertension.

  18. Circulating Blood eNOS Contributes to the Regulation of Systemic Blood Pressure and Nitrite Homeostasis

    Science.gov (United States)

    Wood, Katherine C.; Cortese-Krott, Miriam M.; Kovacic, Jason C.; Noguchi, Audrey; Liu, Virginia B.; Wang, Xunde; Raghavachari, Nalini; Boehm, Manfred; Kato, Gregory J.; Kelm, Malte; Gladwin, Mark T.

    2013-01-01

    Objective Mice genetically deficient in endothelial nitric oxide synthase (eNOS−/−) are hypertensive with lower circulating nitrite levels, indicating the importance of constitutively produced nitric oxide (NO•) to blood pressure regulation and vascular homeostasis. While the current paradigm holds that this bioactivity derives specifically from expression of eNOS in endothelium, circulating blood cells also express eNOS protein. A functional red cell eNOS that modulates vascular NO• signaling has been proposed. Approach and Results To test the hypothesis that blood cells contribute to mammalian blood pressure regulation via eNOS-dependent NO• generation, we cross-transplanted WT and eNOS−/− mice, producing chimeras competent or deficient for eNOS expression in circulating blood cells. Surprisingly, we observed a significant contribution of both endothelial and circulating blood cell eNOS to blood pressure and systemic nitrite levels, the latter being a major component of the circulating NO• reservoir. These effects were abolished by the NOS inhibitor L-NAME and repristinated by the NOS substrate L-Arginine, and were independent of platelet or leukocyte depletion. Mouse erythrocytes were also found to carry an eNOS protein and convert 14C-Arginine into 14C-Citrulline in a NOS-dependent fashion. Conclusions These are the first studies to definitively establish a role for a blood borne eNOS, using cross transplant chimera models, that contributes to the regulation of blood pressure and nitrite homeostasis. This work provides evidence suggesting that erythrocyte eNOS may mediate this effect. PMID:23702660

  19. Self-reported knowledge and awareness about blood pressure and hypertension

    DEFF Research Database (Denmark)

    Qvist, Ina; Thomsen, Marie D; Lindholt, Jes S

    2014-01-01

    BACKGROUND: In general, it is assumed that patient education, by increasing knowledge, may change behavior and lifestyle and promote health. In this context, it is a surprise that knowledge and awareness about blood pressure and hypertension among elderly people is poor. We hypothesized...... that knowledge about blood pressure and hypertension would be better among individuals with self-reported hypertension compared with subjects without self-reported hypertension. METHODS: We mailed a questionnaire to a random sample of 1,000 subjects living in the municipality of Silkeborg, Denmark. The study...... often had a family history of hypertension. More than 80% reported that overweight and obesity increases blood pressure. More than 60% reported that untreated hypertension may cause heart disease or stroke. More than half of the responders did not know their blood pressure, and only 21% knew...

  20. The diagnostic value of supine blood pressure in hypertension.

    Science.gov (United States)

    Krzesiński, Paweł; Stańczyk, Adam; Gielerak, Grzegorz; Piotrowicz, Katarzyna; Banak, Małgorzata; Wójcik, Agnieszka

    2016-04-01

    Correct blood pressure (BP) measurement is crucial in the diagnosis of arterial hypertension (AH), and controversy exists whether supine BP should be treated as equal to sitting BP. The aim of this study was to evaluate the relation of supine BP to sitting BP and ambulatory BP with regard to identification of diagnostic cut-offs for hypertension. This study included 280 patients with AH (mean age: 44.3 ±10.6 years). The following measurements of BP were performed and analyzed: 1) sitting office blood pressure measurement (OSBP and ODBP); 2) supine BP (supSBP and supDBP), measured automatically (5 times with a 2-minute interval) during evaluation by the Niccomo device (Medis, Germany); 3) 24-hour ambulatory blood pressure (ABP) monitoring. The mean supSBP and supDBP were found to be lower than OSBP and ODBP (130.9 ±14.2 vs. 136.6 ±15.5 mm Hg and 84.8 ±9.4 vs. 87.8 ±10.2 mm Hg, respectively; p AUC: 0.820 vs. 0.550; sensitivity 80.7% vs. 57.4%; specificity 83.2% vs. 52.7%; p blood pressure during a 10-minute supine rest was lower than in the sitting position. The supine blood pressure ≥ 130/80 mm Hg was found to be a specific and sensitive threshold for hypertension.