WorldWideScience

Sample records for nonconducted p-wave arrhythmias

  1. P wave detector with PP rhythm tracking: evaluation in different arrhythmia contexts

    International Nuclear Information System (INIS)

    Portet, François

    2008-01-01

    Automatic detection of atrial activity (P waves) in an electrocardiogram (ECG) is a crucial task to diagnose the presence of arrhythmias. The P wave is difficult to detect and most of the approaches in the literature have been evaluated on normal sinus rhythms and rarely considered arrhythmia contexts other than atrial flutter and fibrillation. A novel knowledge-based P wave detector algorithm is presented. It is self-adaptive to the patient and able to deal with certain arrhythmias by tracking the PP rhythm. The detector has been tested on 12 records of the MIT-BIH arrhythmia database containing several ventricular and supra-ventricular arrhythmias. On the overall records, the detector demonstrates Se = 96.60% and Pr = 95.46%; for the normal sinus rhythm, it reaches Se = 97.76% and Pr = 96.80% and, in the case of Mobitz type II, it demonstrates Se = 72.79% and Pr = 99.51%. It also shows good performance for trigeminy and bigeminy, and outperforms some more sophisticated techniques. Although the results emphasize the difficulty of P wave detection in difficult arrhythmias (supra and ventricular tachycardias), it shows that domain knowledge can efficiently support signal processing techniques

  2. Arrhythmia during extracorporeal shock wave lithotripsy.

    Science.gov (United States)

    Zeng, Z R; Lindstedt, E; Roijer, A; Olsson, S B

    1993-01-01

    A prospective study of arrhythmia during extracorporeal shock wave lithotripsy (ESWL) was performed in 50 patients, using an EDAP LT01 piezoelectric lithotriptor. The 12-lead standard ECG was recorded continuously for 10 min before and during treatment. One or more atrial and/or ventricular ectopic beats occurred during ESWL in 15 cases (30%). The occurrence of arrhythmia was similar during right-sided and left-sided treatment. One patient developed multifocal ventricular premature beats and ventricular bigeminy; another had cardiac arrest for 13.5 s. It was found that various irregularities of the heart rhythm can be caused even by treatment with a lithotriptor using piezoelectric energy to create the shock wave. No evidence was found, however, that the shock wave itself rather than vagal activation and the action of sedo-analgesia was the cause of the arrhythmia. For patients with severe underlying heart disease and a history of complex arrhythmia, we suggest that the ECG be monitored during treatment. In other cases, we have found continuous monitoring of oxygen saturation and pulse rate with a pulse oximeter to be perfectly reliable for raising the alarm when depression of respiration and vaso-vagal reactions occur.

  3. Electromechanical wave imaging for arrhythmias

    International Nuclear Information System (INIS)

    Provost, Jean; Nguyen, Vu Thanh-Hieu; Legrand, Diégo; Okrasinski, Stan; Costet, Alexandre; Konofagou, Elisa E; Gambhir, Alok; Garan, Hasan

    2011-01-01

    Electromechanical wave imaging (EWI) is a novel ultrasound-based imaging modality for mapping of the electromechanical wave (EW), i.e. the transient deformations occurring in immediate response to the electrical activation. The correlation between the EW and the electrical activation has been established in prior studies. However, the methods used previously to map the EW required the reconstruction of images over multiple cardiac cycles, precluding the application of EWI for non-periodic arrhythmias such as fibrillation. In this study, new imaging sequences are developed and applied based on flash- and wide-beam emissions to image the entire heart at very high frame rates (2000 fps) during free breathing in a single heartbeat. The methods are first validated by imaging the heart of an open-chest canine while simultaneously mapping the electrical activation using a 64-electrode basket catheter. Feasibility is then assessed by imaging the atria and ventricles of closed-chest, conscious canines during sinus rhythm and during right-ventricular pacing following atrio-ventricular dissociation, i.e., during a non-periodic rhythm. The EW was validated against electrode measurements in the open-chest case, and followed the expected electrical propagation pattern in the closed-chest setting. These results indicate that EWI can be used for the characterization of non-periodic arrhythmias in conditions similar to the clinical setting, in a single heartbeat, and during free breathing. (fast track communication)

  4. Spiral Wave Initiation in Reaction-Diffusion-Mechanics Systems: A Model for the Onset of Reentrant Cardiac Arrhythmia

    NARCIS (Netherlands)

    Weise, L.D.

    2012-01-01

    Heart failure due to cardiac arrhythmias is a major cause of death in the industrialized world. Cardiac arrhythmia is often caused by spi- ral waves of electrical activity in the cardiac muscle. Therefore, it is a major task in cardiology to understand the mechanisms of spiral wave initiation in the

  5. Micro Electro Discharge Machining for Nonconductive Ceramic Materials

    Directory of Open Access Journals (Sweden)

    Mohammad Yeakub Ali

    2018-03-01

    Full Text Available In micro-electro discharge machining (micro-EDM of nonconductive ceramics, material is removed mainly by spalling due to the dominance of alternating thermal load. The established micro-EDM models established for single spark erosion are not applicable for nonconductive ceramics because of random spalling. Moreover, it is difficult to create single spark on a nonconductive ceramic workpiece when the spark is initiated by the assisting electrode. In this paper, theoretical model of material removal rate (MRR as the function of capacitance and voltage is developed for micro-EDM of nonconductive zirconium oxide (ZrO2. It is shown that the charging and discharging duration depend on the capacitance and resistances of the circuit. The number of sparks per unit time is estimated from the single spark duration s derived from heat transfer fundamentals. The model showed that both the capacitance and voltage are significant process parameters where any increase of capacitance and voltage increases the MRR. However, capacitance was found to be the dominating parameter over voltage. As in case of higher capacitances, the creation of a conductive carbonic layer on the machined surface was not stable; the effective window of machining 101 - 103 pF capacitance and 80 - 100 V gap voltage or 10 - 470 pF capacitance and 80 - 110 V gap voltage. This fact was confirmed EDX analysis where the presence of high carbon content was evident. Conversely, the spark was found to be inconsistent using parameters beyond these ranges and consequently insignificant MRR. Nevertheless, the effective number of sparks per second were close to the predicted numbers when machining conductive copper material. In addition, higher percentage of ineffective pulses was observed during the machining which eventually reduced the MRR. In case of validation, average deviations between the predicted and experimental values were found to be around 10%. Finally, micro-channels were machined on

  6. Adrenergic stimulation promotes T-wave alternans and arrhythmia inducibility in a TNF-alpha genetic mouse model of congestive heart failure.

    Science.gov (United States)

    Shusterman, Vladimir; McTiernan, Charles F; Goldberg, Anna; Saba, Samir; Salama, Guy; London, Barry

    2010-02-01

    T-wave alternans (TWA) is a proarrhythmic repolarization instability that is common in congestive heart failure (CHF). Although transgenic mice are commonly used to study the mechanisms of arrhythmogenesis in CHF, little is known about the dynamics of TWA in these species. We hypothesized that TWA is present in a TNF-alpha model of CHF and can be further promoted by adrenergic stimulation. We studied 16 TNF-alpha mice and 12 FVB controls using 1) in vivo intracardiac electrophysiological testing and 2) ambulatory telemetry during 30 min before and after an intraperitoneal injection of isoproterenol. TWA was examined using both linear and nonlinear filtering applied in the time domain. In addition, changes in the mean amplitude of the T wave and area under the T wave were computed. During intracardiac electrophysiological testing, none of the animals had TWA or inducible arrhythmias before the injection of isoproterenol. After the injection, sustained TWA and inducible ventricular tachyarrhythmias were observed in TNF-alpha mice but not in FVB mice. In ambulatory telemetry, before the isoproterenol injection, the cardiac cycle length (CL) was longer in TNF-alpha mice than in FVB mice (98 +/- 9 and 88 +/- 3 ms, P = 0.04). After the injection of isoproterenol, the CL became 8% and 6% shorter in TNF-alpha and FVB mice (P mice, the magnitude of TWA was 1.5-2 times greater than in FVB mice both before and after the isoproterenol injection. The magnitude of TWA increased significantly after the isoproterenol injection compared with the baseline in TNF-alpha mice (P = 0.003) but not in FVB mice. The mean amplitude of the T wave and area under the T wave increased 60% and 80% in FVB mice (P = 0.006 and 0.009) but not in TNF-alpha mice. In conclusion, TWA is present in a TNF-alpha model of CHF and can be further promoted by adrenergic stimulation, along with the enhanced susceptibility for ventricular arrhythmias.

  7. New theory of arrhythmia. Conceptual substantiation of arrhythmia mechanisms

    Directory of Open Access Journals (Sweden)

    Vladimir I. Ermoshkin

    2015-11-01

    Full Text Available Aims A new attempt is made to substantiate the concept of the mechanism of arrhythmia and sudden cardiac death. Methods The paper is based on a theoretical analysis of special literature, personal experience of participation in conferences and discussions with leading Russian cardiologists. Results We have succeeded in demonstrating the fact that researchers ignore the fact that cardiomyocytes can be excited by mechanical pulses, when considering the arrhythmia mechanisms. We have conducted trials using the Cardiocode device. Under stress in a human, opened may be large and small arteriovenous anastomoses, via which blood under high pressure is ejected into veins. It leads to pressure surges in arteries and veins. The vena cava dilates, its tonus increases. In some cases, the pulse waves travel via anastomoses along the vena cava walls to the atria and the ventricles. An above-threshold concentration of tensions from mechanical pulses may excite cardiomyocytes from different points of the myocardium, disturbing the sinus rhythm. As a result, extrasystoles, tachycardia attacks, blocking of blood circulation in the peripheral segments of the venous arterial networks, edemata, thrombosis and metabolism disorders appear. Arrhythmia, tachycardia attacks and concomitant myocardial ischemia lead to progression of heart fibrosis. Such changes increase the probability of fibrillations and sudden cardiac death. Conclusion Unhealthy lifestyle, the presence of opening and not properly closing anastomoses may provoke a number of diseases. To avoid the cardiac arrhythmia attacks and prevent SCD, it is necessary to suppress travel of the mechanical waves within the following circuitry: aorta – artery – anastomosis – vein – vena cava – atria – ventricles. The travel of the mechanical waves within the same vessel circuitry explains the fact that the fixed couplings under extrasystoles are observed, and the beat-to-beat RR intervals under tachycardia

  8. P-wave and QT dispersion in patients with conversion disorder

    Directory of Open Access Journals (Sweden)

    Izci F

    2015-03-01

    Full Text Available Filiz Izci,1 Hilal Hocagil,2 Servet Izci,3 Vedat Izci,4 Merve Iris Koc,5 Rezzan Deniz Acar3 1Department of Psychiatry, Istanbul Bilim University, Sisli Florence Nightingale Hospital; 2Department of Emergency, Faculty of Medicine Hospital Zonguldak Bulent Ecevit University, Zonguldak, Turkey; 3Department of Cardiology, Kosuyolu High Specialization Training and Research Hospital, Istanbul, Turkey; 4Department of Emergency, Kartal Training and Research Hospital, Istanbul, Turkey; 5Department of Psychiatry, Erenköy Training and Research Hospital for Psychiatry, Istanbul, Turkey Objective: The aim of this study was to investigate QT dispersion (QTd, which is the noninvasive marker of ventricular arrhythmia and sudden cardiac death, and P-wave dispersion, which is the noninvasive marker of atrial arrhythmia, in patients with conversion disorder (CD.Patients and methods: A total of 60 patients with no known organic disease who were admitted to outpatient emergency clinic and were diagnosed with CD after psychiatric consultation were included in this study along with 60 healthy control subjects. Beck Anxiety Inventory and Beck Depression Scale were administered to patients and 12-lead electrocardiogram measurements were obtained. Pd and QTd were calculated by a single blinded cardiologist.Results: There was no statistically significant difference in terms of age, sex, education level, socioeconomic status, weight, height, and body mass index between CD patients and controls. Beck Anxiety Inventory scores (25.2±10.8 and 3.8±3.2, respectively, P<0.001 and Beck Depression Scale scores (11.24±6.15 and 6.58±5.69, respectively, P<0.01 were significantly higher in CD patients. P-wave dispersion measurements did not show any significant differences between conversion patients and control group (46±5.7 vs 44±5.5, respectively, P=0.156. Regarding QTc and QTd, there was a statistically significant increase in all intervals in conversion patients (416

  9. Study on the P-wave feature time course as early predictors of paroxysmal atrial fibrillation

    International Nuclear Information System (INIS)

    Martínez, Arturo; Alcaraz, Raúl; Rieta, José J

    2012-01-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia in clinical practice, increasing the risk of stroke and all-cause mortality. Its mechanisms are poorly understood, thus leading to different theories and controversial interpretation of its behavior. In this respect, it is unknown why AF is self-terminating in certain individuals, which is called paroxysmal AF (PAF), and not in others. Within the context of biomedical signal analysis, predicting the onset of PAF with a reasonable advance has been a clinical challenge in recent years. By predicting arrhythmia onset, the loss of normal sinus rhythm could be addressed by means of preventive treatments, thus minimizing risks for the patients and improving their quality of life. Traditionally, the study of PAF onset has been undertaken through a variety of features characterizing P-wave spatial diversity from the standard 12-lead electrocardiogram (ECG) or from signal-averaged ECGs. However, the variability of features from the P-wave time course before PAF onset has not been exploited yet. This work introduces a new alternative to assess time diversity of the P-wave features from single-lead ECG recordings. Furthermore, the method is able to assess the risk of arrhythmia 1 h before its onset, which is a relevant advance in order to provide clinically useful PAF risk predictors. Results were in agreement with the electrophysiological changes taking place in the atria. Hence, P-wave features presented an increasing variability as PAF onset approximates, thus suggesting intermittently disturbed conduction in the atrial tissue. In addition, high PAF risk prediction accuracy, greater than 90%, has been reached in the two considered scenarios, i.e. discrimination between healthy individuals and PAF patients and between patients far from PAF and close to PAF onset. Nonetheless, more long-term studies have to be analyzed and validated in future works. (paper)

  10. Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves

    Directory of Open Access Journals (Sweden)

    Mohamed Elgendi

    2015-07-01

    Full Text Available Background: There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Methods: Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry. Results: The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats. Conclusions: We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design.

  11. P-wave and QT dispersion in patients with conversion disorder.

    Science.gov (United States)

    Izci, Filiz; Hocagil, Hilal; Izci, Servet; Izci, Vedat; Koc, Merve Iris; Acar, Rezzan Deniz

    2015-01-01

    The aim of this study was to investigate QT dispersion (QTd), which is the noninvasive marker of ventricular arrhythmia and sudden cardiac death, and P-wave dispersion, which is the noninvasive marker of atrial arrhythmia, in patients with conversion disorder (CD). A total of 60 patients with no known organic disease who were admitted to outpatient emergency clinic and were diagnosed with CD after psychiatric consultation were included in this study along with 60 healthy control subjects. Beck Anxiety Inventory and Beck Depression Scale were administered to patients and 12-lead electrocardiogram measurements were obtained. Pd and QTd were calculated by a single blinded cardiologist. There was no statistically significant difference in terms of age, sex, education level, socioeconomic status, weight, height, and body mass index between CD patients and controls. Beck Anxiety Inventory scores (25.2±10.8 and 3.8±3.2, respectively, Pconversion patients and control group (46±5.7 vs 44±5.5, respectively, P=0.156). Regarding QTc and QTd, there was a statistically significant increase in all intervals in conversion patients (416±10 vs 398±12, Pdisorders was also observed in CD patients. QTc and QTd were significantly increased compared to the control group in patients with CD. These results suggest a possibility of increased risk of ventricular arrhythmia resulting from QTd in CD patients. Larger samples are needed to evaluate the clinical course and prognosis in terms of arrhythmia risk in CD patients.

  12. Effects of Single Dose Energy Drink on QT and P-Wave Dispersion

    OpenAIRE

    Arınç, Hüseyin; Sarli, Bahadir; Baktir, Ahmet Oguz; Yolcu, Mustafa; Ozyildirim, Serhan; Kayardi, Mahmut; Cosgun, Mehmet; Erguzel, Nuri; Gunduz, Huseyin; Uyan, Cihangir

    2013-01-01

    Objective: Aim of this study is to evaluate the cardiac electrophysiological effects of energy drink (Red Bull) on QT and P duration and dispersion on surface electrocardiogram.Methods: Twenty healthy volunteers older than 17 years of age were included the study. Subjects with a cardiac rhythm except sinus rhythm, history of atrial or ventricular arrhythmia, family history of premature sudden cardiac death, palpitations, T-wave abnormalities, QTc interval greater than 440 milliseconds, or tho...

  13. Effects of Single Dose Energy Drink on QT and P-Wave Dispersion

    Directory of Open Access Journals (Sweden)

    Huseyin Arinc

    2013-12-01

    Full Text Available INTRODUCTION: Aim of this study is to evaluate the cardiac electrophysiological effects of energy drink (Red Bull on QT and P duration and dispersion on surface electrocardiogram. METHODS: Twenty healthy volunteers older than 17 years of age were included the study. Subjects with a cardiac rhythm except sinus rhythm, history of atrial or ventricular arrhythmia, family history of premature sudden cardiac death, palpitations, T-wave abnormalities, QTc interval greater than 440 milliseconds, or those P-waves and QT intervals unavailable in at least eight ECG leads were excluded. Subjects having insomnia, lactose intolerance, caffeine allergy, recurrent headaches, depression, any psychiatric condition, and history of alcohol or drug abuse, pregnant or lactating women were also excluded from participation. 12 lead ECG was obtained before and after consumption of 250 cc enegry drink. QT and P-wave dispersion was calculated. RESULTS: No significant difference have occurred in heart rate (79 ± 14 vs.81 ±13, p=0.68, systolic pressure (114 ± 14 vs.118 ± 16,p=0.38, diastolic blood pressure (74 ± 12 vs.76 ± 14, p=0.64, QT dispersion (58 ± 12 vs. 57 ± 22, p= 0.785 and P-wave dispersion (37 ± 7 vs. 36 ± 13, p= 0.755 between before and 2 hours after consumption of energy drink. DISCUSSION AND CONCLUSION: Consumption of single dose energy drink doesn't affect QT dispersion and P-wave dispersion, heart rate and blood pressure in healthy adults.

  14. AV-block and conduction slowing prevail over TdP arrhythmias in the methoxamine-sensitized pro-arrhythmic rabbit model.

    Science.gov (United States)

    Varkevisser, Rosanne; Vos, Marc A; Beekman, Jet D; Tieland, Ralph G; Van Der Heyden, Marcel A

    2015-01-01

    The methoxamine-sensitized rabbit model is widely used to screen drugs for proarrhythmic properties, especially repolarization-dependent TdP arrhythmias. With the change of anesthesia and/or sensitizing agent, conduction disturbances have been reported as well. Therefore, we compared currently available in-house anesthetics in order to preserve arrhythmia sensitivity and preclude conduction disturbances. Rabbits were randomly assigned to 3 groups: (1) 35 mg/kg ketamine + 5 mg/kg xylazine; (2) 0.5 mL/kg hypnorm + 3 mg/kg midazolam; (3) 35 mg/kg ketamine + 20 mg/kg propofol. Anesthesia was maintained by 1.5% isoflurane. Concomitant infusion of methoxamine (17 μg/kg/min for 40 minutes) and dofetilide (10 μg/kg/min for 30 minutes) was used to induce arrhythmias. Sole methoxamine infusion exclusively decreased HR in groups 1 and 3. Dofetilide lengthened repolarization, followed in time by PQ/QRS prolongation, second-degree AV block, and subsequently TdP arrhythmias. TdP was seen in 80%, 0%, and 33% of the rabbits in groups 1, 2, and 3, respectively. Decreasing the dose of dofetilide to 5 μg/kg/min in ketamine/xylazine anesthetized rabbits resulted in a drop in TdP incidence (25%) while conduction disturbances persisted. Flunarizine (n = 6) suppressed all TdP arrhythmias while conduction disturbances remained present. TdP incidence in the methoxamine-sensitized rabbit could be dramatically influenced by anesthesia, drug dose, and flunarizine, while conduction slowing remained present. Thus, conduction slowing seems to be the integral outcome in this model. © 2014 Wiley Periodicals, Inc.

  15. On the resolution of ECG acquisition systems for the reliable analysis of the P-wave

    International Nuclear Information System (INIS)

    Censi, Federica; Calcagnini, Giovanni; Mattei, Eugenio; Triventi, Michele; Bartolini, Pietro; Corazza, Ivan; Boriani, Giuseppe

    2012-01-01

    The analysis of the P-wave on surface ECG is widely used to assess the risk of atrial arrhythmias. In order to provide reliable results, the automatic analysis of the P-wave must be precise and reliable and must take into account technical aspects, one of those being the resolution of the acquisition system. The aim of this note is to investigate the effects of the amplitude resolution of ECG acquisition systems on the P-wave analysis. Starting from ECG recorded by an acquisition system with a less significant bit (LSB) of 31 nV (24 bit on an input range of 524 mVpp), we reproduced an ECG signal as acquired by systems with lower resolution (16, 15, 14, 13 and 12 bit). We found that, when the LSB is of the order of 128 µV (12 bit), a single P-wave is not recognizable on ECG. However, when averaging is applied, a P-wave template can be extracted, apparently suitable for the P-wave analysis. Results obtained in terms of P-wave duration and morphology revealed that the analysis of ECG at lowest resolutions (from 12 to 14 bit, LSB higher than 30 µV) could lead to misleading results. However, the resolution used nowadays in modern electrocardiographs (15 and 16 bit, LSB <10 µV) is sufficient for the reliable analysis of the P-wave. (note)

  16. Two markers in predicting the cardiovascular events in patients with polycystic ovary syndrome: increased P-wave and QT dispersion.

    Science.gov (United States)

    Akdag, S; Cim, N; Yildizhan, R; Akyol, A; Ozturk, F; Babat, N

    2015-09-01

    Polycystic ovary syndrome (PCOS) is a prevalent disease with many potential long-term cardiovascular risks. P-wave dispersion (Pdis) and QT dispersion (QTdis) have been shown to be noninvasive electrocardiographic predictors for development of cardiac arrhythmias. In this study we aimed to search Pdis and QTdis parameters in patients with PCOS. The study included 82 patients with PCOS and 74 age- and sex-matched healthy controls. Baseline 12-lead electrocardiographic and transthoracic echocardiographic measurements were evaluated. P-wave maximum duration (Pmax), P-wave minimum duration (Pmin), Pdis, QT interval, heart rate-corrected QT dispersion and QTdis were calculated by two cardiologists. Patients wirh PCOS had significantly higher QT dispersion (49.5 ± 14.1 vs. 37.9 ± 12.6 ms, p PCOS patients.

  17. Computer-assisted education system for arrhythmia (CAESAR).

    Science.gov (United States)

    Fukushima, M; Inoue, M; Fukunami, M; Ishikawa, K; Inada, H; Abe, H

    1984-08-01

    A computer-assisted education system for arrhythmia (CAESAR) was developed for students to acquire the ability to logically diagnose complicated arrhythmias. This system has a logical simulator of cardiac rhythm using a mathematical model of the impulse formation and conduction system of the heart. A simulated arrhythmia (ECG pattern) is given on a graphic display unit with simulated series of the action potential of five pacemaker centers and the "ladder diagram" of impulse formation and conduction, which show the mechanism of that arrhythmia. For the purpose of the evaluation of this system, 13 medical students were given two types of tests concerning arrhythmias before and after 2-hr learning with this system. The scores they obtained after learning increased significantly from 73.3 +/- 11.9 to 93.2 +/- 3.0 (P less than 0.001) in one test and from 47.2 +/- 17.9 to 64.9 +/- 19.6 (P less than 0.001) in another one. These results proved that this CAI system is useful and effective for training ECG interpretation of arrhythmias.

  18. The predictive value of P-wave duration by signal-averaged electrocardiogram in acute ST elevation myocardial infarction.

    Science.gov (United States)

    Shturman, Alexander; Bickel, Amitai; Atar, Shaul

    2012-08-01

    The prognostic value of P-wave duration has been previously evaluated by signal-averaged ECG (SAECG) in patients with various arrhythmias not associated with acute myocardial infarction (AMI). To investigate the clinical correlates and prognostic value of P-wave duration in patients with ST elevation AMI (STEMI). The patients (n = 89) were evaluated on the first, second and third day after admission, as well as one week and one month post-AMI. Survival was determined 2 years after the index STEMI. In comparison with the upper normal range of P-wave duration ( 40% (128.79 +/- 28 msec) (P = 0.001). P-wave duration above 120 msec was significantly correlated with increased complication rate; namely, sustained ventricular tachyarrhythmia (36%), congestive heart failure (41%), atrial fibrillation (11%), recurrent angina (14%), and re-infarction (8%) (P = 0.012, odds ratio 4.267, 95% confidence interval 1.37-13.32). P-wave duration of 126 msec on the day of admission was found to have the highest predictive value for in-hospital complications including LVEF 40% (area under the curve 0.741, P < 0.001). However, we did not find a significant correlation between P-wave duration and mortality after multivariate analysis. P-wave duration as evaluated by SAECG correlates negatively with LVEF post-STEMI, and P-wave duration above 126 msec can be utilized as a non-invasive predictor of in-hospital complications and low LVEF following STEMI.

  19. β1-Adrenoceptor blocker aggravated ventricular arrhythmia.

    Science.gov (United States)

    Wang, Yan; Patel, Dimpi; Wang, Dao Wu; Yan, Jiang Tao; Hsia, Henry H; Liu, Hao; Zhao, Chun Xia; Zuo, Hou Juan; Wang, Dao Wen

    2013-11-01

    To assess the impact of β1 -adrenoceptor blockers (β1 -blocker) and isoprenaline on the incidence of idiopathic repetitive ventricular arrhythmia that apparently decreases with preprocedural anxiety. From January 2010 to July 2012, six patients were identified who had idiopathic ventricular arrhythmias that apparently decreased (by greater than 90%) with preprocedural anxiety. The number of ectopic ventricular beats per hour (VPH) was calculated from Holter or telemetry monitoring to assess the ectopic burden. The mean VPH of 24 hours from Holter before admission (VPH-m) was used as baseline (100%) for normalization. β1 -Blockers, isoprenaline, and/or aminophylline were administrated successively on the ward and catheter lab to evaluate their effects on the ventricular arrhythmias. Among 97 consecutive patients with idiopathic ventricular arrhythmias, six had reduction in normalized VPHs in the hour before the scheduled procedure time from (104.6 ± 4.6%) to (2.8 ± 1.6%) possibly due to preprocedural anxiety (P < 0.05), then increased to (97.9 ± 9.7%) during β1 -blocker administration (P < 0.05), then quickly reduced to (1.6 ± 1.0%) during subsequent isoprenaline infusion. Repeated β1 -blocker quickly counteracted the inhibitory effect of isoprenaline, and VPHs increased to (120.9 ± 2.4%) from (1.6 ± 1.0%; P < 0.05). Isoprenaline and β1 -blocker showed similar effects on the arrhythmias in catheter lab. In some patients with structurally normal heart and ventricular arrhythmias there is a marked reduction of arrhythmias associated with preprocedural anxiety. These patients exhibit a reproducible sequence of β1 -blocker aggravation and catecholamine inhibition of ventricular arrhythmias, including both repetitive ventricular premature beats and monomorphic ventricular tachycardia. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  20. Detecting the Elusive P-Wave: A New ECG Lead to Improve the Recording of Atrial Activity.

    Science.gov (United States)

    Kennedy, Alan; Finlay, Dewar D; Guldenring, Daniel; Bond, Raymond R; McLaughlin, James

    2016-02-01

    In this study, we report on a lead selection method that was developed to detect the optimal bipolar electrode placement for recording of the P-wave. The study population consisted of 117 lead body surface potential maps recorded from 229 healthy subjects. The optimal bipolar lead was developed using the training set (172 subjects) then extracted from the testing dataset (57 subjects) and compared to other lead systems previously reported for improved recording of atrial activity. All leads were assessed in terms of P-wave, QRS, and STT root mean square (RMS). The P/QRST RMS ratio was also investigated to determine the atrioventricular RMS ratio. Finally, the effect of minor electrode misplacements on the P-lead was investigated. The P-lead discovered in this study outperformed all other investigated leads in terms of P-wave RMS. The P-lead showed a significant improvement in median P-wave RMS (93 versus 72 μV, p < 0.001) over the next best lead, Lead II. An improvement in QRS and STT RMS was also observed from the P-lead in comparison to lead II (668 versus 573 μV, p < 0.001) and (327 versus 196 μV, p < 0.001). Although P-wave RMS was reduced by incorrect electrode placement, significant improvement over Lead II was still evident. The P-lead improves P-wave RMS signal strength over all other investigated leads. Also the P-lead does not reduce QRS and STT RMS making it an appropriate choice for atrial arrhythmia monitoring. Given the improvement in signal-to-noise ratio, an improvement in algorithms that rely on P-wave analysis may be achieved.

  1. Malignant Arrhythmia in Apical Ballooning Syndrome: Risk Factors and Outcomes

    Directory of Open Access Journals (Sweden)

    Samuel J. Asirvatham

    2008-08-01

    Full Text Available Objectives: We sought to determine the frequency and outcomes with symptomatic arrhythmia in patients with apical ballooning syndrome (ABS. Methods: A retrospective review of the Mayo Clinic Angiography database was conducted to identify patients who met the Mayo criteria for ABS. Patients with documented arrhythmias formed the study group, and 31 randomly selected patients with ABS but without arrhythmia formed the control group.Results: Out of 105 patients identified with ABS, 6 (5.7% women aged 69 +/- 9 years experienced significant arrhythmia (ventricular fibrillation, asystole, 2 patients died, and 1 required permanent pacemaker implantation. When compared with controls, the study group showed no significant difference with respect to ECG characteristics (QT, QRS duration or axis except for R-R interval variability (see comments below (30.6±6 vs 14.5±17 p = 0.0004, QTc, and P-R interval. Patients without arrhythmia were more likely to be on beta-blocker therapy than the study population (33% vs 80.6% p = 0.02. Conclusion: Life-threatening arrhythmia is uncommon (5.7% with ABS despite marked, structural abnormalities. When arrhythmias do occur, the outcome is poor. Prominent variability in R-R intervals appears to be predictive of significant arrhythmias in ABS. The role of beta-blocker therapy in preventing arrhythmia with ABS requires further investigation.

  2. P wave analysis indices in young healthy men: data from the digital electrocardiographic study in Hellenic Air Force Servicemen (DEHAS).

    Science.gov (United States)

    Gialafos, Elias J; Dilaveris, Polychronis E; Synetos, Andreas G; Tsolakidis, George F; Papaioannou, Theodoros G; Andrikopoulos, George K; Richter, Dimitris J; Triposkiadis, Filippos; Gialafos, John E

    2003-01-01

    P wave analysis from the 12-lead ECG is a recent contribution of noninvasive electrocardiology. P wave analysis indices (maximum and minimum P wave duration, P wave dispersion [Pdis = Pmax-Pmin], adjusted P wave dispersion [APdis = Pdis/square root of measured leads], summated P wave duration [Psum], standard deviation of P wave duration [Psd], mean P wave duration [Pmean]) can predict atrial arrhythmias. However, the definitions of all these indices are based on few studies. The aim of this analysis was to define normal values of these indices and the examine possible associations between P wave indices and clinical variables. The study included 1,353 healthy men, 24 +/- 3 years of age, who answered a questionnaire and underwent a detailed physical examination and a digitized 12-lead surface ECG. All P wave indices were analyzed by two independent investigators. Mean values of the ECG indices were: Pmax: 96 +/- 11 ms, Pmin: 57 +/- 9 ms, Pdis: 38 +/- 10 ms, Psum: 924 +/- 96 ms, Psd: 12 +/- 3, APdis: 11 +/- 3 ms, and Pmean: 77 +/- 8 ms. Age was significantly related with Pmax (r = 0.277, P < 0.01), Pmin (r = 0.255, P < 0.001), Psum (r = 0.074, P < 0.01), and Pmean (r = 0.074, P < 0.01). All ECG indices were significantly associated with the R-R interval, and among each other. This study defined normal indices of wave duration and correlations among them. These markers may play an important predictive role in patients with atrial conduction abnormalities.

  3. Arrhythmias

    Science.gov (United States)

    ... some herbal remedies); injuries to the heart from chest trauma or heart surgery; use of illegal drugs, alcohol, or tobacco; caffeine; and stress. Arrhythmias also can happen for no apparent reason. Signs and ... of breath chest pain fainting Arrhythmias can ...

  4. Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

    Directory of Open Access Journals (Sweden)

    Umair Aziz

    2015-12-01

    Full Text Available Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from July 2013 to November 2014 were included. On admission, twelve-lead electrocardiogram (ECG was performed for all patients. During admission, all patients underwent continuous cardiac monitoring using a cardiac monitor. If an arrhythmia was suspected on the cardiac monitor, another ECG was obtained immediately.  Results: During the study period, 100 patients with AlP poisoning (63% men were treated at Allied Hospital Faisalabad. Mean age of the patients was 26.7 ± 7.9 years ranging from 16 to 54 years. Tachycardia was detected in 68 patients and bradycardia in 12 patients. Hypotension was observed in 75 patients. Eighty patients developed cardiac arrhythmia. The most frequent arrhythmia was atrial fibrillation (31% of patients followed by ventricular fibrillation (20%, ventricular tachycardia (17%, 3rd degree AV block (7% and 2nd degree AV block (5%. In total, 78 patients died, depicting a 78% mortality rate following wheat pill poisoning. Among those who died, seventy-one patients had cardiac arrhythmia. Comparison of death rate between patients with and without cardiac arrhythmia showed a significant difference (71/80 (88.8% vs. 7/20 (35%; P < 0.001.  Conclusion: Wheat pill poisoning causes a very high mortality, and circulatory collapse is the major cause of death among these patients. Most of the patients with AlP poisoning develop cardiac arrhythmias which are invariably life threatening. Early detection of cardiac disorders and proper management of arrhythmias may reduce mortalities.

  5. Method for electrically producing dispersions of a nonconductive fluid in a conductive medium

    Science.gov (United States)

    DePaoli, David W.; Tsouris, Constantinos; Feng, James Q.

    1998-01-01

    A method for use in electrically forming dispersions of a nonconducting fluid in a conductive medium that minimizes power consumption, gas generation, and sparking between the electrode of the nozzle and the conductive medium. The method utilizes a nozzle having a passageway, the wall of which serves as the nozzle electrode, for the transport of the nonconducting fluid into the conductive medium. A second passageway provides for the transport of a flowing low conductivity buffer fluid which results in a region of the low conductivity buffer fluid immediately adjacent the outlet from the first passageway to create the necessary protection from high current drain and sparking. An electrical potential difference applied between the nozzle electrode and an electrode in contact with the conductive medium causes formation of small droplets or bubbles of the nonconducting fluid within the conductive medium. A preferred embodiment has the first and second passageways arranged in a concentric configuration, with the outlet tip of the first passageway withdrawn into the second passageway.

  6. Adapting detection sensitivity based on evidence of irregular sinus arrhythmia to improve atrial fibrillation detection in insertable cardiac monitors.

    Science.gov (United States)

    Pürerfellner, Helmut; Sanders, Prashanthan; Sarkar, Shantanu; Reisfeld, Erin; Reiland, Jerry; Koehler, Jodi; Pokushalov, Evgeny; Urban, Luboš; Dekker, Lukas R C

    2017-10-03

    Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  7. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  8. Competing p-wave orders

    International Nuclear Information System (INIS)

    Donos, Aristomenis; Gauntlett, Jerome P; Pantelidou, Christiana

    2014-01-01

    We construct electrically charged, asymptotically AdS 5 black hole solutions that are dual to d = 4 CFTs in a superfluid phase with either p-wave or (p + ip)-wave order. The two types of black holes have non-vanishing charged two-form in the bulk and appear at the same critical temperature in the unbroken phase. Both the p-wave and the (p + ip)-wave phase can be thermodynamically preferred, depending on the mass and charge of the two-form, and there can also be first order transitions between them. The p-wave black holes have a helical structure and some of them exhibit the phenomenon of pitch inversion as the temperature is decreased. Both the p-wave and the (p + ip)-wave black holes have zero entropy density ground states at zero temperature and we identify some new ground states which exhibit scaling symmetry, including a novel scenario for the emergence of conformal symmetry in the IR. (paper)

  9. AV-block and conduction slowing prevail over TdP arrhythmias in the methoxamine-sensitized pro-arrhythmic rabbit model

    NARCIS (Netherlands)

    Varkevisser, Rosanne; Vos, Marc A; Beekman, Jet; Tieland, Ralph G; Van Der Heyden, Marcel A

    INTRODUCTION: The methoxamine-sensitized rabbit model is widely used to screen drugs for proarrhythmic properties, especially repolarization-dependent TdP arrhythmias. With the change of anesthesia and/or sensitizing agent, conduction disturbances have been reported as well. Therefore, we compared

  10. Role of the P-wave high frequency energy and duration as noninvasive cardiovascular predictors of paroxysmal atrial fibrillation.

    Science.gov (United States)

    Alcaraz, Raúl; Martínez, Arturo; Rieta, José J

    2015-04-01

    A normal cardiac activation starts in the sinoatrial node and then spreads throughout the atrial myocardium, thus defining the P-wave of the electrocardiogram. However, when the onset of paroxysmal atrial fibrillation (PAF) approximates, a highly disturbed electrical activity occurs within the atria, thus provoking fragmented and eventually longer P-waves. Although this altered atrial conduction has been successfully quantified just before PAF onset from the signal-averaged P-wave spectral analysis, its evolution during the hours preceding the arrhythmia has not been assessed yet. This work focuses on quantifying the P-wave spectral content variability over the 2h preceding PAF onset with the aim of anticipating as much as possible the arrhythmic episode envision. For that purpose, the time course of several metrics estimating absolute energy and ratios of high- to low-frequency power in different bands between 20 and 200Hz has been computed from the P-wave autoregressive spectral estimation. All the analyzed metrics showed an increasing variability trend as PAF onset approximated, providing the P-wave high-frequency energy (between 80 and 150Hz) a diagnostic accuracy around 80% to discern between healthy subjects, patients far from PAF and patients less than 1h close to a PAF episode. This discriminant power was similar to that provided by the most classical time-domain approach, i.e., the P-wave duration. Furthermore, the linear combination of both metrics improved the diagnostic accuracy up to 88.07%, thus constituting a reliable noninvasive harbinger of PAF onset with a reasonable anticipation. The information provided by this methodology could be very useful in clinical practice either to optimize the antiarrhythmic treatment in patients at high-risk of PAF onset and to limit drug administration in low risk patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PRwave sensing intermittently present during sinus tachycardia); (2) programming settings (atrial fibrillation/atrial flutter with ventricular rate above the SVT limit); and (3) algorithm limitations (atrial tachycardia with ventricular rate around the shortest programmable SVT limit and SVT redetection following VT therapy). Programming measures improved detection ability in 13 of 59 of inappropriately detected arrhythmias. Dual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to

  12. Hypertension and cardiac arrhythmias

    DEFF Research Database (Denmark)

    Lip, Gregory Y.H.; Coca, Antonio; Kahan, Thomas

    2017-01-01

    Hypertension is a common cardiovascular risk factor leading to heart failure (HF), coronary artery disease, stroke, peripheral artery disease and chronic renal insufficiency. Hypertensive heart disease can manifest as many cardiac arrhythmias, most commonly being atrial fibrillation (AF). Both...... supraventricular and ventricular arrhythmias may occur in hypertensive patients, especially in those with left ventricular hypertrophy (LVH) or HF. Also, some of the antihypertensive drugs commonly used to reduce blood pressure, such as thiazide diuretics, may result in electrolyte abnormalities (e.g. hypokalaemia......, hypomagnesemia), further contributing to arrhythmias, whereas effective control of blood pressure may prevent the development of the arrhythmias such as AF. In recognizing this close relationship between hypertension and arrhythmias, the European Heart Rhythm Association (EHRA) and the European Society...

  13. Micro Electro Discharge Machining of Electrically Nonconductive Ceramics

    International Nuclear Information System (INIS)

    Schubert, A.; Zeidler, H.; Hackert, M.; Wolf, N.

    2011-01-01

    EDM is a known process for machining of hard and brittle materials. Due to its noncontact and nearly forceless behaviour, it has been introduced into micro manufacturing and through constant development it is now an important means for producing high-precision micro geometries. One restriction of EDM is its limitation to electrically conducting materials.Today many applications, especially in the biomedical field, make use of the benefits of ceramic materials, such as high strength, very low wear and biocompatibility. Common ceramic materials such as Zirconium dioxide are, due to their hardness in the sintered state, difficult to machine with conventional cutting techniques. A demand for the introduction of EDM to these materials could so far not be satisfied because of their nonconductive nature.At the Chemnitz University of Technology and the Fraunhofer IWU, investigations in the applicability of micro-EDM for the machining of nonconductive ceramics are being conducted. Tests are undertaken using micro-EDM drilling with Tungsten carbide tool electrodes and ZrO 2 ceramic workpieces. A starting layer, in literature often referred to as 'assisting electrode' is used to set up a closed electric circuit to start the EDM process. Combining carbon hydride based dielectric and a specially designed low-frequency vibration setup to excite the workpiece, the process environment can be held within parameters to allow for a constant EDM process even after the starting layer is machined. In the experiments a cylindrical 120 μm diameter Tungsten carbide tool electrode and Y 2 O 3 - and MgO- stabilized ZrO 2 worpieces are used. The current and voltage signals of the discharges within the different stages of the process (machining of the starting layer, machining of the base material, transition stage) are recorded and their characteristics compared to discharges in metallic material. Additionally, the electrode feed is monitored. The influences of the process parameters are

  14. Frequency of cardiac arrhythmias in high and low- yielding dairy cows

    Directory of Open Access Journals (Sweden)

    Afshin Jafari Dehkordi

    2014-06-01

    Full Text Available Electrocardiography (ECG may be used to recognize cardiac disorders. Levels of milk production may change the serum electrolytes which its imbalance has a role in cardiac arrhythmia. Fifty high yielding and fifty low yielding Holstein dairy cows were used in this study. Electrocardiography was recorded by base-apex lead and blood samples were collected from jugular vein for measurement of serum elements such as sodium, potassium, calcium, phosphorous, iron and magnesium. Cardiac dysrhythmias were detected more frequent in low yielding Holstein cows (62.00% compared to high yielding Holstein cows (46.00%. The cardiac dysrhythmias that were observed in low yielding Holstein cows included sinus arrhythmia (34.70%, wandering pacemaker (22.45 %, bradycardia (18.37%, tachycardia (10.20%, atrial premature beat (2.04%, sinoatrial block (2.04%, atrial fibrillation (8.16% and atrial tachycardia (2.04%. The cardiac dysrhythmias were observed in high yielding Holstein cows including, sinus arrhythmia (86.95% and wandering pacemaker (13.05%. Also, notched P wave was observed to be 30% and 14% in high- and low- yielding Holstein cows respectively. The serum calcium concentration of low yielding Holstein cows was significantly lower than that of high yielding Holstein cows. There was not any detectable significant difference in other serum elements between high- and low- yielding Holstein cows. Based on the result of present study, could be concluded that low serum concentration of calcium results to more frequent dysrhythmias in low yielding Holstein cows.

  15. Integration of conducting polymer network in non-conductive polymer substrates

    DEFF Research Database (Denmark)

    Hansen, Thomas Steen; West, Keld; Hassager, Ole

    2006-01-01

    Anew method for integration ofconjugated, inherently conducting polymers into non-conductive polymer substrates has been developed. Alayer of the conducting polymer is polymerised by chemical oxidation, e.g. using Fe(ID) p-toluene sulfonate (ferri tosylate) followed by washing with a solvent which...... simultaneously removes residual and spent oxidant and at the same time dissolves the top layer of the polymer substrate. This results in an integration of the conducting polymer into the surface layers of the polymer substrate. Several combinations of conducting polymers and substrates have been tested...... absorption during sequential reactive ion etching has allowed for analysis of the PEDOT distribution within the surface layer of thePMMA substrate. The surface resistance ofthe conducting polymer layer remains low while the surface layer at the same time adapts some of the mechanical properties...

  16. Arrhythmias (For Parents)

    Science.gov (United States)

    ... some herbal remedies ); injuries to the heart from chest trauma or heart surgery; use of illegal drugs, alcohol, or tobacco; caffeine; and stress. Arrhythmias can be temporary or permanent. An ... of breath chest pain fainting Arrhythmias can ...

  17. Suspension chemistry and electrophoretic deposition of zirconia electrolyte on conducting and non-conducting substrates

    International Nuclear Information System (INIS)

    Das, Debasish; Basu, Rajendra N.

    2013-01-01

    Graphical abstract: - Highlights: • Stable suspension of yttria stabilized zirconia (YSZ) obtained in isopropanol medium. • Suspension chemistry and process parameters for electrophoretic deposition optimized. • Deposited film quality changed with iodine and water (dispersants) concentration. • Dense YSZ film (∼5 μm) fabricated onto non-conducting porous NiO-YSZ anode substrate. - Abstract: Suspensions of 8 mol% yttria stabilized zirconia (YSZ) particulates in isopropanol medium are prepared using acetylacetone, iodine and water as dispersants. The effect of dispersants concentration on suspension stability, particle size distribution, electrical conductivity and pH of the suspensions are studied in detail to optimize the suspension chemistry. Electrophoretic deposition (EPD) has been conducted to produce thin and dense YSZ electrolyte films. Deposition kinetics have been studied in depth and good quality films on conducting substrate are obtained at an applied voltage of 15 V for 3 min. YSZ films are also fabricated on non-conducting NiO-YSZ anode substrate using a steel plate on the reverse side of the substrate. Upon co-firing at 1400 °C for 6 h a dense YSZ film of thickness ∼5 μm is obtained. Such a half cell (anode + electrolyte) can be used to fabricate a solid oxide fuel cell on applying a suitable cathode layer

  18. Evaluation of QT and P wave dispersion and mean platelet volume among inflammatory bowel disease patients.

    Science.gov (United States)

    Dogan, Yuksel; Soylu, Aliye; Eren, Gulay A; Poturoglu, Sule; Dolapcioglu, Can; Sonmez, Kenan; Duman, Habibe; Sevindir, Isa

    2011-01-01

    In inflammatory bowel disease (IBD) number of thromboembolic events are increased due to hypercoagulupathy and platelet activation. Increases in mean platelet volume (MPV) can lead to platelet activation, this leads to thromboembolic events and can cause acute coronary syndromes. In IBD patients, QT-dispersion and P-wave dispersion are predictors of ventricular arrhythmias and atrial fibrilation; MPV is accepted as a risk factor for acute coronary syndromes, we aimed at evaluating the correlations of these with the duration of disease, its localization and activity. The study group consisted of 69 IBD (Ulcerative colitis n: 54, Crohn's Disease n: 15) patients and the control group included 38 healthy individuals. Disease activity was evaluated both endoscopically and clinically. Patients with existing cardiac conditions, those using QT prolonging medications and having systemic diseases, anemia and electrolyte imbalances were excluded from the study. QT-dispersion, P-wave dispersion and MPV values of both groups were compared with disease activity, its localization, duration of disease and the antibiotics used. The P-wave dispersion values of the study group were significantly higher than those of the control group. Duration of the disease was not associated with QT-dispersion, and MPV levels. QT-dispersion, P-wave dispersion, MPV and platelet count levels were similar between the active and in mild ulcerative colitis patients. QT-dispersion levels were similar between IBD patients and the control group. No difference was observed between P-wave dispersion, QT-dispersion and MPV values; with regards to disease duration, disease activity, and localization in the study group (p>0.05). P-wave dispersion which is accepted as a risk factor for the development of atrial fibirilation was found to be high in our IBD patients. This demonstrates us that the risk of developing atrial fibrillation may be high in patients with IBD. No significant difference was found in the QT

  19. Increasing Prevalence of Atrial Fibrillation and Permanent Atrial Arrhythmias in Congenital Heart Disease.

    Science.gov (United States)

    Labombarda, Fabien; Hamilton, Robert; Shohoudi, Azadeh; Aboulhosn, Jamil; Broberg, Craig S; Chaix, Marie A; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Macle, Laurent; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Khairy, Paul

    2017-08-15

    Atrial arrhythmias are the most common complication encountered in the growing and aging population with congenital heart disease. This study sought to assess the types and patterns of atrial arrhythmias, associated factors, and age-related trends. A multicenter cohort study enrolled 482 patients with congenital heart disease and atrial arrhythmias, age 32.0 ± 18.0 years, 45.2% female, from 12 North American centers. Qualifying arrhythmias were classified by a blinded adjudicating committee. The most common presenting arrhythmia was intra-atrial re-entrant tachycardia (IART) (61.6%), followed by atrial fibrillation (28.8%), and focal atrial tachycardia (9.5%). The proportion of arrhythmias due to IART increased with congenital heart disease complexity from 47.2% to 62.1% to 67.0% in patients with simple, moderate, and complex defects, respectively (p = 0.0013). Atrial fibrillation increased with age to surpass IART as the most common arrhythmia in those ≥50 years of age (51.2% vs. 44.2%; p congenital heart disease, with a predominantly paroxysmal pattern. However, atrial fibrillation increases in prevalence and atrial arrhythmias progressively become permanent as the population ages. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Calcium-dependent arrhythmias in transgenic mice with heart failure.

    Science.gov (United States)

    London, Barry; Baker, Linda C; Lee, Joon S; Shusterman, Vladimir; Choi, Bum-Rak; Kubota, Toru; McTiernan, Charles F; Feldman, Arthur M; Salama, Guy

    2003-02-01

    Transgenic mice overexpressing the inflammatory cytokine tumor necrosis factor (TNF)-alpha (TNF-alpha mice) in the heart develop a progressive heart failure syndrome characterized by biventricular dilatation, decreased ejection fraction, atrial and ventricular arrhythmias on ambulatory telemetry monitoring, and decreased survival compared with nontransgenic littermates. Programmed stimulation in vitro with single extra beats elicits reentrant ventricular arrhythmias in TNF-alpha (n = 12 of 13 hearts) but not in control hearts. We performed optical mapping of voltage and Ca(2+) in isolated perfused ventricles of TNF-alpha mice to study the mechanisms that lead to the initiation and maintenance of the arrhythmias. When compared with controls, hearts from TNF-alpha mice have prolonged of action potential durations (action potential duration at 90% repolarization: 23 +/- 2 ms, n = 7, vs. 18 +/- 1 ms, n = 5; P < 0.05), no increased dispersion of refractoriness between apex and base, elevated diastolic and depressed systolic [Ca(2+)], and prolonged Ca(2+) transients (72 +/- 6 ms, n = 10, vs. 54 +/- 5 ms, n = 8; P < 0.01). Premature beats have diminished action potential amplitudes and conduct in a slow, heterogeneous manner. Lowering extracellular [Ca(2+)] normalizes conduction and prevents inducible arrhythmias. Thus both action potential prolongation and abnormal Ca(2+) handling may contribute to the initiation of reentrant arrhythmias in this heart failure model by mechanisms distinct from enhanced dispersion of refractoriness or triggered activity.

  1. Aconitine-induced Ca2+ overload causes arrhythmia and triggers apoptosis through p38 MAPK signaling pathway in rats

    International Nuclear Information System (INIS)

    Sun, Gui-bo; Sun, Hong; Meng, Xiang-bao; Hu, Jin; Zhang, Qiang; Liu, Bo; Wang, Min; Xu, Hui-bo; Sun, Xiao-bo

    2014-01-01

    Aconitine is a major bioactive diterpenoid alkaloid with high content derived from herbal aconitum plants. Emerging evidence indicates that voltage-dependent Na + channels have pivotal roles in the cardiotoxicity of aconitine. However, no reports are available on the role of Ca 2+ in aconitine poisoning. In this study, we explored the importance of pathological Ca 2+ signaling in aconitine poisoning in vitro and in vivo. We found that Ca 2+ overload lead to accelerated beating rhythm in adult rat ventricular myocytes and caused arrhythmia in conscious freely moving rats. To investigate effects of aconitine on myocardial injury, we performed cytotoxicity assay in neonatal rat ventricular myocytes (NRVMs), as well as measured lactate dehydrogenase level in the culture medium of NRVMs and activities of serum cardiac enzymes in rats. The results showed that aconitine resulted in myocardial injury and reduced NRVMs viability dose-dependently. To confirm the pro-apoptotic effects, we performed flow cytometric detection, cardiac histology, transmission electron microscopy and terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling assay. The results showed that aconitine stimulated apoptosis time-dependently. The expression analysis of Ca 2+ handling proteins demonstrated that aconitine promoted Ca 2+ overload through the expression regulation of Ca 2+ handling proteins. The expression analysis of apoptosis-related proteins revealed that pro-apoptotic protein expression was upregulated, and anti-apoptotic protein BCL-2 expression was downregulated. Furthermore, increased phosphorylation of MAPK family members, especially the P-P38/P38 ratio was found in cardiac tissues. Hence, our results suggest that aconitine significantly aggravates Ca 2+ overload and causes arrhythmia and finally promotes apoptotic development via phosphorylation of P38 mitogen-activated protein kinase. - Highlights: • Aconitine-induced Ca 2+ overload causes arrhythmia in rats

  2. Patient characteristics associated with false arrhythmia alarms in intensive care

    Directory of Open Access Journals (Sweden)

    Harris PR

    2017-04-01

    ventricular bradycardia as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. Results: A total of 461 unique patients (mean age =60±17 years were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5% were determined to be false. Two hundred and fifty patients (54% generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%. The number of false alarms per monitored hour for patients’ annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1 the number and 2 the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years (P=0.013; P=0.034, confused mental status (P<0.001 for both comparisons, cardiovascular diagnoses (P<0.001 for both comparisons, electrocardiographic (ECG features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB (P=0.003; P=0.004 or ventricular paced rhythm (P=0.002 for both comparisons, respiratory diagnoses (P=0.004 for both comparisons, and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones (P<0.001 for both comparisons. Conclusion: Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or

  3. Ventricular arrhythmias in Chagas disease

    Directory of Open Access Journals (Sweden)

    Marco Paulo Tomaz Barbosa

    2015-02-01

    Full Text Available Sudden death is one of the most characteristic phenomena of Chagas disease, and approximately one-third of infected patients develop life-threatening heart disease, including malignant ventricular arrhythmias. Fibrotic lesions secondary to chronic cardiomyopathy produce arrhythmogenic substrates that lead to the appearance and maintenance of ventricular arrhythmias. The objective of this study is to discuss the main clinical and epidemiological aspects of ventricular arrhythmias in Chagas disease, the specific workups and treatments for these abnormalities, and the breakthroughs needed to determine a more effective approach to these arrhythmias. A literature review was performed via a search of the PubMed database from 1965 to May 31, 2014 for studies of patients with Chagas disease. Clinical management of patients with chronic Chagas disease begins with proper clinical stratification and the identification of individuals at a higher risk of sudden cardiac death. Once a patient develops malignant ventricular arrhythmia, the therapeutic approach aims to prevent the recurrence of arrhythmias and sudden cardiac death by the use of implantable cardioverter defibrillators, antiarrhythmic drugs, or both. In select cases, invasive ablation of the reentrant circuit causing tachycardia may be useful. Ventricular arrhythmias are important manifestations of Chagas cardiomyopathy. This review highlights the absence of high-quality evidence regarding the treatment of ventricular arrhythmias in Chagas disease. Recognizing high-risk patients who require specific therapies, especially invasive procedures such as the implantation of cardioverter defibrillators and ablative approaches, is a major challenge in clinical practice.

  4. Sleep Apnea and Nocturnal Cardiac Arrhythmia: A Populational Study

    Directory of Open Access Journals (Sweden)

    Fatima Dumas Cintra

    2014-11-01

    Full Text Available Background: The mechanisms associated with the cardiovascular consequences of obstructive sleep apnea include abrupt changes in autonomic tone, which can trigger cardiac arrhythmias. The authors hypothesized that nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea. Objective: To analyze the relationship between obstructive sleep apnea and abnormal heart rhythm during sleep in a population sample. Methods: Cross-sectional study with 1,101 volunteers, who form a representative sample of the city of São Paulo. The overnight polysomnography was performed using an EMBLA® S7000 digital system during the regular sleep schedule of the individual. The electrocardiogram channel was extracted, duplicated, and then analyzed using a Holter (Cardio Smart® system. Results: A total of 767 participants (461 men with a mean age of 42.00 ± 0.53 years, were included in the analysis. At least one type of nocturnal cardiac rhythm disturbance (atrial/ventricular arrhythmia or beat was observed in 62.7% of the sample. The occurrence of nocturnal cardiac arrhythmias was more frequent with increased disease severity. Rhythm disturbance was observed in 53.3% of the sample without breathing sleep disorders, whereas 92.3% of patients with severe obstructive sleep apnea showed cardiac arrhythmia. Isolated atrial and ventricular ectopy was more frequent in patients with moderate/severe obstructive sleep apnea when compared to controls (p < 0.001. After controlling for potential confounding factors, age, sex and apnea-hypopnea index were associated with nocturnal cardiac arrhythmia. Conclusion: Nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea and the prevalence increases with disease severity. Age, sex, and the Apnea-hypopnea index were predictors of arrhythmia in this sample.

  5. Estimating the Wet-Rock P-Wave Velocity from the Dry-Rock P-Wave Velocity for Pyroclastic Rocks

    Science.gov (United States)

    Kahraman, Sair; Fener, Mustafa; Kilic, Cumhur Ozcan

    2017-07-01

    Seismic methods are widely used for the geotechnical investigations in volcanic areas or for the determination of the engineering properties of pyroclastic rocks in laboratory. Therefore, developing a relation between the wet- and dry-rock P-wave velocities will be helpful for engineers when evaluating the formation characteristics of pyroclastic rocks. To investigate the predictability of the wet-rock P-wave velocity from the dry-rock P-wave velocity for pyroclastic rocks P-wave velocity measurements were conducted on 27 different pyroclastic rocks. In addition, dry-rock S-wave velocity measurements were conducted. The test results were modeled using Gassmann's and Wood's theories and it was seen that estimates for saturated P-wave velocity from the theories fit well measured data. For samples having values of less and greater than 20%, practical equations were derived for reliably estimating wet-rock P-wave velocity as function of dry-rock P-wave velocity.

  6. P wave dispersion and maximum P wave duration are independently associated with rapid renal function decline.

    Science.gov (United States)

    Su, Ho-Ming; Tsai, Wei-Chung; Lin, Tsung-Hsien; Hsu, Po-Chao; Lee, Wen-Hsien; Lin, Ming-Yen; Chen, Szu-Chia; Lee, Chee-Siong; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2012-01-01

    The P wave parameters measured by 12-lead electrocardiogram (ECG) are commonly used as noninvasive tools to assess for left atrial enlargement. There are limited studies to evaluate whether P wave parameters are independently associated with decline in renal function. Accordingly, the aim of this study is to assess whether P wave parameters are independently associated with progression to renal end point of ≥25% decline in estimated glomerular filtration rate (eGFR). This longitudinal study included 166 patients. The renal end point was defined as ≥25% decline in eGFR. We measured two ECG P wave parameters corrected by heart rate, i.e. corrected P wave dispersion (PWdisperC) and corrected P wave maximum duration (PWdurMaxC). Heart function and structure were measured from echocardiography. Clinical data, P wave parameters, and echocardiographic measurements were compared and analyzed. Forty-three patients (25.9%) reached renal end point. Kaplan-Meier curves for renal end point-free survival showed PWdisperC > median (63.0 ms) (log-rank P = 0.004) and PWdurMaxC > median (117.9 ms) (log-rank Pfunction decline.

  7. Dynamic tunneling force microscopy for characterizing electronic trap states in non-conductive surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Wang, R.; Williams, C. C., E-mail: clayton@physics.utah.edu [Department of Physics and Astronomy, University of Utah, Salt Lake City, Utah 84112 (United States)

    2015-09-15

    Dynamic tunneling force microscopy (DTFM) is a scanning probe technique for real space mapping and characterization of individual electronic trap states in non-conductive films with atomic scale spatial resolution. The method is based upon the quantum mechanical tunneling of a single electron back and forth between a metallic atomic force microscopy tip and individual trap states in completely non-conducting surface. This single electron shuttling is measured by detecting the electrostatic force induced on the probe tip at the shuttling frequency. In this paper, the physical basis for the DTFM method is unfolded through a physical model and a derivation of the dynamic tunneling signal as a function of several experimental parameters is shown. Experimental data are compared with the theoretical simulations, showing quantitative consistency and verifying the physical model used. The experimental system is described and representative imaging results are shown.

  8. Aconitine-induced Ca{sup 2+} overload causes arrhythmia and triggers apoptosis through p38 MAPK signaling pathway in rats

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gui-bo; Sun, Hong; Meng, Xiang-bao [Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100193 (China); Hu, Jin; Zhang, Qiang; Liu, Bo [Academy of Chinese Medical Sciences of Jilin Province, Changchun, Jilin 130021 (China); Wang, Min [Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100193 (China); Xu, Hui-bo, E-mail: xhb_6505@163.com [Academy of Chinese Medical Sciences of Jilin Province, Changchun, Jilin 130021 (China); Sun, Xiao-bo, E-mail: sun_xiaobo163@163.com [Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100193 (China)

    2014-08-15

    Aconitine is a major bioactive diterpenoid alkaloid with high content derived from herbal aconitum plants. Emerging evidence indicates that voltage-dependent Na{sup +} channels have pivotal roles in the cardiotoxicity of aconitine. However, no reports are available on the role of Ca{sup 2+} in aconitine poisoning. In this study, we explored the importance of pathological Ca{sup 2+} signaling in aconitine poisoning in vitro and in vivo. We found that Ca{sup 2+} overload lead to accelerated beating rhythm in adult rat ventricular myocytes and caused arrhythmia in conscious freely moving rats. To investigate effects of aconitine on myocardial injury, we performed cytotoxicity assay in neonatal rat ventricular myocytes (NRVMs), as well as measured lactate dehydrogenase level in the culture medium of NRVMs and activities of serum cardiac enzymes in rats. The results showed that aconitine resulted in myocardial injury and reduced NRVMs viability dose-dependently. To confirm the pro-apoptotic effects, we performed flow cytometric detection, cardiac histology, transmission electron microscopy and terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling assay. The results showed that aconitine stimulated apoptosis time-dependently. The expression analysis of Ca{sup 2+} handling proteins demonstrated that aconitine promoted Ca{sup 2+} overload through the expression regulation of Ca{sup 2+} handling proteins. The expression analysis of apoptosis-related proteins revealed that pro-apoptotic protein expression was upregulated, and anti-apoptotic protein BCL-2 expression was downregulated. Furthermore, increased phosphorylation of MAPK family members, especially the P-P38/P38 ratio was found in cardiac tissues. Hence, our results suggest that aconitine significantly aggravates Ca{sup 2+} overload and causes arrhythmia and finally promotes apoptotic development via phosphorylation of P38 mitogen-activated protein kinase. - Highlights: • Aconitine-induced Ca

  9. Sports and arrhythmias: a report of the International Workshop Venice Arrhythmias 2009.

    Science.gov (United States)

    Giada, Franco; Biffi, Alessandro; Cannom, David S; Cappato, Riccardo; Capucci, Alessandro; Corrado, Domenico; Delise, Pietro; Drezner, Jonathan A; El-Sherif, Nabil; Estes, Mark; Furlanello, Francesco; Heidbuchel, Hein; Inama, Giuseppe; Lindsay, Bruce D; Maron, Barry J; Maron, Martin S; Mont, Luis; Olshansky, Brian; Pelliccia, Antonio; Thiene, Gaetano; Viskin, Sami; Zeppilli, Paolo; Natale, Andrea; Raviele, Antonio

    2010-10-01

    This article is a report of an international symposium, endorsed by the Section on Sports Cardiology of the European Association for Cardiovascular Prevention and Rehabilitation, the Italian Society of Sports Cardiology, and the Italian Federation of Sports Medicine, which was held within the 11th International Workshop on Cardiac Arrhythmias (Venice Arrhythmias 2009, Venice, Italy, October 2009). The following main topics were discussed during the symposium: the role of novel diagnostic examinations to assess the risk of sudden death in athletes, controversies on arrhythmic risk evaluation in athletes, controversies on the relationship between sports and arrhythmias, and controversies on antiarrhythmic treatment in athletes.

  10. Arrhythmias

    Science.gov (United States)

    ... sign of other heart problems, or an immediate danger to your health. ... patient with suspected arrhythmia. In: Goldman L, Schafer AI, eds. Goldman’s Cecil Medicine . 25th ed. Philadelphia, PA: ...

  11. Electrically nonconductive shield for electric equipment generating ionizing radiation

    International Nuclear Information System (INIS)

    Aitken, D.

    1979-01-01

    As a radiation protection shield there is proposed a nonconductive shield fabricated from epoxides or other plastics material and containing finely dispersed radiation absorbing metal. It is to be designed in such a way that it lies in the range of a high electric gradient in the equipment, close to the radiation-producing component. As suitable metals there are mentioned tin, tungsten, and lead resp. their oxides. As an example there is used an X-ray shielding. (RW) 891 RW/RW 892 MKO [de

  12. Tube Inner Coating of Non-Conductive Films by Pulsed Reactive Coaxial Magnetron Plasma with Outer Anode

    Directory of Open Access Journals (Sweden)

    Musab Timan Idriss Gasab

    2018-03-01

    Full Text Available The double-ended coaxial magnetron pulsed plasma (DCMPP method with auxiliary outer anode was introduced in order to achieve the uniform coating of non-conductive thin films on the inner walls of insulator tubes. In this study, titanium (Ti was employed as a cathode (sputtering target, and a glass tube was used as a substrate. In an argon (Ar and oxygen (O2 gas mixture, magnetron plasma was generated. Oxygen gas was introduced to deposit a titanium oxide (TiO2 film. A comparison between films coated with and without an auxiliary outer anode was made. As a result, it was clearly shown that the DCMPP method using an auxiliary outer anode enhanced the uniformity of the deposited non-conductive film compared to the conventional DCMPP method. Moreover, the optimum conditions under which the thin TiO2 film was deposited on the inner wall of the glass tube were revealed. From the results, it was supposed that the auxiliary outer anode contributed to the uniformity of the distributions of deposited negative charge on the non-conductive film and consequently the electric field and the plasma density uniform.

  13. Damping properties of non-conductive composite materials for applications in power transmission pylons

    DEFF Research Database (Denmark)

    Kliem, Mathias; Rüppel, Marvin; Høgsberg, Jan

    2018-01-01

    This study aims to characterize the fibre direction dependent damping properties of non-conductive composite materialsto be used in newly designed electrical power transm°ission pylons, on which the conducting cables will be directlyconnected. Thus, the composite structure can be designed both to...

  14. Geometrical aspects in optical wave-packet dynamics.

    Science.gov (United States)

    Onoda, Masaru; Murakami, Shuichi; Nagaosa, Naoto

    2006-12-01

    We construct a semiclassical theory for propagation of an optical wave packet in a nonconducting medium with a periodic structure of dielectric permittivity and magnetic permeability, i.e., a nonconducting photonic crystal. We employ a quantum-mechanical formalism in order to clarify its link to those of electronic systems. It involves the geometrical phase, i.e., Berry's phase, in a natural way, and describes an interplay between orbital motion and internal rotation. Based on the above theory, we discuss the geometrical aspects of the optical Hall effect. We also consider a reduction of the theory to a system without periodic structure and apply it to the transverse shift of an optical beam at an interface reflection or refraction. For a generic incident beam with an arbitrary polarization, an identical result for the transverse shift of each reflected or transmitted beam is given by the following different approaches: (i) analytic evaluation of wave-packet dynamics, (ii) total angular momentum (TAM) conservation for individual photons, and (iii) numerical simulation of wave-packet dynamics. It is consistent with a result by classical electrodynamics. This means that the TAM conservation for individual photons is already taken into account in wave optics, i.e., classical electrodynamics. Finally, we show an application of our theory to a two-dimensional photonic crystal, and propose an optimal design for the enhancement of the optical Hall effect in photonic crystals.

  15. Electrophoretic deposition of thin film zirconia electrolyte on non-conducting NiO-YSZ substrate

    International Nuclear Information System (INIS)

    Das, Debasish; Basu, Rajendra N.

    2014-01-01

    Eight (8) mol% yttria stabilized zirconia (YSZ), an electrolyte material for solid oxide fuel cell (SOFC), has been deposited onto porous non-conducting NiO-YSZ substrate using electrophoretic deposition technique (EPD) from a stable non-aqueous suspension of YSZ. Normally, EPD cannot be performed on a non-conducting substrate, but, in this present study, YSZ particulate film has been successfully deposited on a non-conducting NiO-YSZ substrate following two different EPD approaches:(a) using a conducting metallic plate on the reverse side of the porous NiO-YSZ anode substrate and (b) using a conducting polymer coated NiO-YSZ substrate. The deposited films are then formed dense coatings of 5-15 μm after sintering at 1400℃ for 6 h in air. Surface and cross-sectional morphologies of green and sintered films deposited by different EPD approaches are investigated using SEM. La 0.65 Sr 0.3 MnO 3 (LSM), a cathode for SOFC, is then screen-printed onto the electrolyte layer of such sintered half cells (anode+electrolyte) prepared by both the above approaches to construct SOFC single cells. A maximum output power density of 0.37 W.cm -2 is obtained using single cells prepared by conducting metallic plate assisted EPD compared to that of 0.73 W.cm -2 for polymer coated at 800℃ using H 2 as fuel and O 2 as oxidant. (author)

  16. Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Woong; Kwon, Hyuk Chan; Kim, Ki Dam; Lee, Yong Ho; Kim, Jin Mok; Kim, In Seon; Lim, Hyun Kyoon; Park, Yong Ki [Biomagnetism Research, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Kim, Doo Sang [Seoul Veterans Hospital, Seoul (Korea, Republic of); Lim, Seung Pyung [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2005-10-15

    We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was 10 fT/Hz(a) 1 Hz and 5 fT/Hz(a) 100 Hz. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  17. Earthquake early warning using P-waves that appear after initial S-waves

    Science.gov (United States)

    Kodera, Y.

    2017-12-01

    As measures for underprediction for large earthquakes with finite faults and overprediction for multiple simultaneous earthquakes, Hoshiba (2013), Hoshiba and Aoki (2015), and Kodera et al. (2016) proposed earthquake early warning (EEW) methods that directly predict ground motion by computing the wave propagation of observed ground motion. These methods are expected to predict ground motion with a high accuracy even for complicated scenarios because these methods do not need source parameter estimation. On the other hand, there is room for improvement in their rapidity because they predict strong motion prediction mainly based on the observation of S-waves and do not explicitly use P-wave information available before the S-waves. In this research, we propose a real-time P-wave detector to incorporate P-wave information into these wavefield-estimation approaches. P-waves within a few seconds from the P-onsets are commonly used in many existing EEW methods. In addition, we focus on P-waves that may appear in the later part of seismic waves. Kurahashi and Irikura (2013) mentioned that P-waves radiated from strong motion generation areas (SMGAs) were recognizable after S-waves of the initial rupture point in the 2011 off the Pacific coast of Tohoku earthquake (Mw 9.0) (the Tohoku-oki earthquake). Detecting these P-waves would enhance the rapidity of prediction for the peak ground motion generated by SMGAs. We constructed a real-time P-wave detector that uses a polarity analysis. Using acceleration records in boreholes of KiK-net (band-pass filtered around 0.5-10 Hz with site amplification correction), the P-wave detector performed the principal component analysis with a sliding window of 4 s and calculated P-filter values (e.g. Ross and Ben-Zion, 2014). The application to the Tohoku-oki earthquake (Mw 9.0) showed that (1) peaks of P-filter that corresponded to SMGAs appeared in several stations located near SMGAs and (2) real-time seismic intensities (Kunugi et al

  18. Temporal abstraction and inductive logic programming for arrhythmia recognition from electrocardiograms.

    Science.gov (United States)

    Carrault, G; Cordier, M-O; Quiniou, R; Wang, F

    2003-07-01

    This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.

  19. Arrhythmia phenotype in mouse models of human long QT.

    Science.gov (United States)

    Salama, Guy; Baker, Linda; Wolk, Robert; Barhanin, Jacques; London, Barry

    2009-03-01

    Enhanced dispersion of repolarization (DR) was proposed as a unifying mechanism, central to arrhythmia genesis in the long QT (LQT) syndrome. In mammalian hearts, K(+) channels are heterogeneously expressed across the ventricles resulting in 'intrinsic' DR that may worsen in long QT. DR was shown to be central to the arrhythmia phenotype of transgenic mice with LQT caused by loss of function of the dominant mouse K(+) currents. Here, we investigated the arrhythmia phenotype of mice with targeted deletions of KCNE1 and KCNH2 genes which encode for minK/IsK and Merg1 (mouse homolog of human ERG) proteins resulting in loss of function of I(Ks) and I(Kr), respectively. Both currents are important human K(+) currents associated with LQT5 and LQT2. Loss of minK, a protein subunit that interacts with KvLQT1, results in a marked reduction of I(Ks) giving rise to the Jervell and Lange-Nielsen syndrome and the reduced KCNH2 gene reduces MERG and I(Kr). Hearts were perfused, stained with di-4-ANEPPS and optically mapped to compare action potential durations (APDs) and arrhythmia phenotype in homozygous minK (minK(-/-)) and heterozygous Merg1 (Merg(+/-)) deletions and littermate control mice. MinK(-/-) mice has similar APDs and no arrhythmias (n = 4). Merg(+/-) mice had prolonged APDs (from 20 +/- 6 to 32 +/- 9 ms at the base, p mice (60% vs. 10%). A comparison of mouse models of LQT based on K(+) channel mutations important to human and mouse repolarization emphasizes DR as a major determinant of arrhythmia vulnerability.

  20. Inhibition of Rac1 reduces store overload-induced calcium release and protects against ventricular arrhythmia.

    Science.gov (United States)

    Zhang, Lili; Lu, Xiangru; Gui, Le; Wu, Yan; Sims, Stephen M; Wang, Guoping; Feng, Qingping

    2016-08-01

    Rac1 is a small GTPase and plays key roles in multiple cellular processes including the production of reactive oxygen species (ROS). However, whether Rac1 activation during myocardial ischaemia and reperfusion (I/R) contributes to arrhythmogenesis is not fully understood. We aimed to study the effects of Rac1 inhibition on store overload-induced Ca(2+) release (SOICR) and ventricular arrhythmia during myocardial I/R. Adult Rac1(f/f) and cardiac-specific Rac1 knockdown (Rac1(ckd) ) mice were subjected to myocardial I/R and their electrocardiograms (ECGs) were monitored for ventricular arrhythmia. Myocardial Rac1 activity was increased and ventricular arrhythmia was induced during I/R in Rac1(f/f) mice. Remarkably, I/R-induced ventricular arrhythmia was significantly decreased in Rac1(ckd) compared to Rac1(f/f) mice. Furthermore, treatment with Rac1 inhibitor NSC23766 decreased I/R-induced ventricular arrhythmia. Ca(2+) imaging analysis showed that in response to a 6 mM external Ca(2+) concentration challenge, SOICR was induced with characteristic spontaneous intracellular Ca(2+) waves in Rac1(f/f) cardiomyocytes. Notably, SOICR was diminished by pharmacological and genetic inhibition of Rac1 in adult cardiomyocytes. Moreover, I/R-induced ROS production and ryanodine receptor 2 (RyR2) oxidation were significantly inhibited in the myocardium of Rac1(ckd) mice. We conclude that Rac1 activation induces ventricular arrhythmia during myocardial I/R. Inhibition of Rac1 suppresses SOICR and protects against ventricular arrhythmia. Blockade of Rac1 activation may represent a new paradigm for the treatment of cardiac arrhythmia in ischaemic heart disease. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  1. Functionalization of silicon nanowires by conductive and non-conductive polymers

    Science.gov (United States)

    Belhousse, S.; Tighilt, F.-Z.; Sam, S.; Lasmi, K.; Hamdani, K.; Tahanout, L.; Megherbi, F.; Gabouze, N.

    2017-11-01

    The work reports on the development of hybrid devices based on silicon nanowires (SiNW) with polymers and the difference obtained when using conductive and non-conductive polymers. SiNW have attracted much attention due to their importance in understanding the fundamental properties at low dimensionality as well as their potential application in nanoscale devices as in field effect transistors, chemical or biological sensors, battery electrodes and photovoltaics. SiNW arrays were formed using metal assisted chemical etching method. This process is simple, fast and allows obtaining a wide range of silicon nanostructures. Hydrogen-passivated SiNW surfaces show relatively poor stability. Surface modification with organic species confers the desired stability and enhances the surface properties. For this reason, this work proposes a covalent grafting of organic material onto SiNW surface. We have chosen a non-conductive polymer polyvinylpyrrolidone (PVP) and conductive polymers polythiophene (PTh) and polypyrrole (PPy), in order to evaluate the electric effect of the polymers on the obtained materials. The hybrid structures were elaborated by the polymerization of the corresponding conjugated monomers by electrochemical route; this electropolymerization offers several advantages such as simplicity and rapidity. SiNW functionalization by conductive polymers has shown to have a huge effect on the electrical mobility. Hybrid surface morphologies were characterized by scanning electron microscopy (SEM), infrared spectroscopy (FTIR-ATR) and contact angle measurements.

  2. In Search of Hidden Arrhythmia

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2015-10-01

    Full Text Available Cardiac rhythm disorders could be very common and minimal significance like isolated ventricular ectopics are very serious and life threatening like ventricular tachycardia or fibrillation. Often it is an irregular pulse or heart beats which calls our attention to the presence of cardiac rhythm disorders. But many times, cardiac arrhythmia is intermittent and not manifest at the time of physical examination. A simple 12 lead electrocardiogram with a long rhythm strip can document cardiac arrhythmia which is frequent, but often fails to record intermittent arrhythmia which can still be quite symptomatic and sometimes life threatenting. This brief review is on the various modalities of electrocardiographic recordings used for documenting arrhythmia which is not easily documented by a 12 lead electrocardiogram with a long rhythm strip.

  3. Noninvasive risk stratification of lethal ventricular arrhythmias and sudden cardiac death after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Kenji Yodogawa, MD

    2014-08-01

    Full Text Available Prediction of lethal ventricular arrhythmias leading to sudden cardiac death is one of the most important and challenging problems after myocardial infarction (MI. Identification of MI patients who are prone to ventricular tachyarrhythmias allows for an indication of implantable cardioverter-defibrillator placement. To date, noninvasive techniques such as microvolt T-wave alternans (MTWA, signal-averaged electrocardiography (SAECG, heart rate variability (HRV, and heart rate turbulence (HRT have been developed for this purpose. MTWA is an indicator of repolarization abnormality and is currently the most promising risk-stratification tool for predicting malignant ventricular arrhythmias. Similarly, late potentials detected by SAECG are indices of depolarization abnormality and are useful in risk stratification. However, the role of SAECG is limited because of its low predictive accuracy. Abnormal HRV and HRT patterns reflect autonomic disturbances, which may increase the risk of lethal ventricular arrhythmias, but the existing evidence is insufficient. Further studies of noninvasive assessment may provide a new insight into risk stratification in post-MI patients.

  4. Lysophosphatidylcholine (LPC) metabolism and cardiac arrhythmias

    International Nuclear Information System (INIS)

    Giffin, D.M.; Man, R.Y.K.; Arthur, G.; Choy, P.C.

    1986-01-01

    The effect of LPC in the production of cardiac arrhythmias in isolated mammalian hearts has been well-documented. Cardiac arrhythmias are initiated by the accumulation of the lysolipid in the cardiac membrane. When isolated rat hearts were perfused in 10 μM LPC for 10 min, severe arrhythmias were observed in all experiments. In isolated guinea pig hearts that were perfused under identical conditions, the development of severe arrhythmias was never observed, and mild arrhythmias were produced in less than 50% of the hearts used. When the hearts of both species were perfused with [ 14 C-palmitate]-LPC, the labellings found in the microsomal fractions (expressed in mg protein) were similar. However, a higher amount of labelled LPC (2-fold) was found in rat heart microsomes, whereas a higher amount of labelled fatty acid was located in the guinea pig heart microsomes. Determination of lysophospholipase activities in these microsomal fractions revealed that the specific activity of the enzyme was much higher in the guinea pig heart than the rat heart. The authors conclude that the differential effect of LPC-induced arrhythmias between the rat and guinea pig heart may be a direct result of the lysophospholipase activities in these hearts. The ability to catabolize LPC more rapidly in the guinea pig heart may decrease the accumulation of LPC in the membrane, and hence, reduce the production of arrhythmias

  5. Classification of ECG signal with Support Vector Machine Method for Arrhythmia Detection

    Science.gov (United States)

    Turnip, Arjon; Ilham Rizqywan, M.; Kusumandari, Dwi E.; Turnip, Mardi; Sihombing, Poltak

    2018-03-01

    An electrocardiogram is a potential bioelectric record that occurs as a result of cardiac activity. QRS Detection with zero crossing calculation is one method that can precisely determine peak R of QRS wave as part of arrhythmia detection. In this paper, two experimental scheme (2 minutes duration with different activities: relaxed and, typing) were conducted. From the two experiments it were obtained: accuracy, sensitivity, and positive predictivity about 100% each for the first experiment and about 79%, 93%, 83% for the second experiment, respectively. Furthermore, the feature set of MIT-BIH arrhythmia using the support vector machine (SVM) method on the WEKA software is evaluated. By combining the available attributes on the WEKA algorithm, the result is constant since all classes of SVM goes to the normal class with average 88.49% accuracy.

  6. Computers and clinical arrhythmias.

    Science.gov (United States)

    Knoebel, S B; Lovelace, D E

    1983-02-01

    Cardiac arrhythmias are ubiquitous in normal and abnormal hearts. These disorders may be life-threatening or benign, symptomatic or unrecognized. Arrhythmias may be the precursor of sudden death, a cause or effect of cardiac failure, a clinical reflection of acute or chronic disorders, or a manifestation of extracardiac conditions. Progress is being made toward unraveling the diagnostic and therapeutic problems involved in arrhythmogenesis. Many of the advances would not be possible, however, without the availability of computer technology. To preserve the proper balance and purposeful progression of computer usage, engineers and physicians have been exhorted not to work independently in this field. Both should learn some of the other's trade. The two disciplines need to come together to solve important problems with computers in cardiology. The intent of this article was to acquaint the practicing cardiologist with some of the extant and envisioned computer applications and some of the problems with both. We conclude that computer-based database management systems are necessary for sorting out the clinical factors of relevance for arrhythmogenesis, but computer database management systems are beset with problems that will require sophisticated solutions. The technology for detecting arrhythmias on routine electrocardiograms is quite good but human over-reading is still required, and the rationale for computer application in this setting is questionable. Systems for qualitative, continuous monitoring and review of extended time ECG recordings are adequate with proper noise rejection algorithms and editing capabilities. The systems are limited presently for clinical application to the recognition of ectopic rhythms and significant pauses. Attention should now be turned to the clinical goals for detection and quantification of arrhythmias. We should be asking the following questions: How quantitative do systems need to be? Are computers required for the detection of

  7. Feasibility and accuracy of a new mobile electrocardiography device, ER-2000®, in the diagnosis of arrhythmia

    Directory of Open Access Journals (Sweden)

    Yae Min Park

    2015-08-01

    Conclusions: A rhythm strip obtained using ER-2000® is accurate in diagnosing arrhythmia, despite some differences in the detailed morphology of the QRS and T-wave, and the pacing spike compared to those obtained by the 12-lead ECG.

  8. Clinical significance of fragmented QRS complexes or J waves in patients with idiopathic ventricular arrhythmias.

    Science.gov (United States)

    Seong, Choong Sil; Gwag, Hye Bin; Hwang, Jin Kyung; Park, Seung Jung; Park, Kyoung-Min; Kim, June Soo; On, Young Keun

    2018-01-01

    Idiopathic ventricular fibrillation (IVF) can cause sudden cardiac death. Previous studies have reported that J waves and fragmented QRS complexes (f-QRS) are arrhythmogenic markers and predictors of cardiac events. We evaluated the prevalence and clinical significance of J waves and f-QRS in patients with IVF. We studied 81 patients who received an implantable cardioverter defibrillator (ICD) due to IVF between October 1999 and June 2015. We assessed the prevalence of J waves and f-QRS using electrocardiograms (ECGs). Patients were classified into three groups: J wave group (n = 35), f-QRS group (n = 20), or normal ECG group (n = 26). The control group included 81 subjects without heart disease who were matched for age, sex, and race. We compared syncope, sudden cardiac arrest, and appropriate ICD shock between the three groups. The follow-up duration was 4.1 years. J waves and f-QRS were more frequent in patients with IVF than in control subjects (43.2%, 21% vs. 24.7%, 19.7%, P J wave and f-QRS versus the normal ECG group revealed that the combined group had a higher frequency of clinical cardiac events than the normal ECG group (47.3% vs. 11.5%, respectively, P = 0.009). Patients with IVF had higher prevalence of f-QRS or J waves. And patients with f-QRS or J waves were at higher risk of recurrent ventricular fibrillation.

  9. The predictive value of CHADS₂ risk score in post myocardial infarction arrhythmias - a Cardiac Arrhythmias and RIsk Stratification after Myocardial infArction (CARISMA) substudy

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine Huth; Gang, Uffe; Thomsen, Poul Erik Bloch

    2014-01-01

    BACKGROUND: Previous studies have shown substantially increased risk of cardiac arrhythmias and sudden cardiac death in post-myocardial infarction (MI) patients. However it remains difficult to identify the patients who are at highest risk of arrhythmias in the post-MI setting. The purpose...... of this study was to investigate if CHADS₂ score (congestive heart failure, hypertension, age ≥75 years, diabetes and previous stroke/TCI [doubled]) can be used as a risk tool for predicting cardiac arrhythmias after MI. METHODS: The study included 297 post-MI patients from the CARISMA study with left....... Patients were stratified according to CHADS₂ score at enrollment. Congestive heart failure was defined as LVEF ≤40% and NYHA class II, III or IV. RESULTS: We found significantly increased risk of an arrhythmic event with increasing CHADS₂ score (CHADS₂ score=1-2: HR=2.1 [1.1-3.9], p=0.021, CHADS₂ score ≥ 3...

  10. Investigation of surface roughness in micro-electro discharge machining of nonconductive ZrO2 for MEMS application

    International Nuclear Information System (INIS)

    Sabur, A; Moudood, A; Ali, M Y; Maleque, M A

    2013-01-01

    Micro-electro discharge machining technique, a noncontact machining process, is applied for drilling blind hole on nonconductive ZrO 2 ceramic for MEMS application. A conductive layer of adhesive copper is applied on the workpiece surface to initiate the sparks. Kerosene is used as dielectric for creation of continuous conductive pyrolytic carbon layer on the machined surface. Experiments are conducted by varying the voltage (V), capacitance (C) and rotational speed (N). Correlating these variables a mathematical model for surface roughness (SR) is developed using Taguchi method. The results showed that the V and C are the significant parameters of SR in micro-EDM for nonconductive ZrO 2 ceramic. The model also showed that SR increases with the increase of V and C

  11. Conducting to non-conducting transition in dual transmission lines using a ternary model with long-range correlated disorder

    International Nuclear Information System (INIS)

    Lazo, E.; Diez, E.

    2010-01-01

    In this work we study the behavior of the allowed and forbidden frequencies in disordered classical dual transmission lines when the values of capacitances {C j } are distributed according to a ternary model with long-range correlated disorder. We introduce the disorder from a random sequence with a power spectrum S(k)∝k -(2α-1) , where α≥0.5 is the correlation exponent. From this sequence we generate an asymmetric ternary map using two map parameters b 1 and b 2 , which adjust the occupancy probability of each possible value of the capacitances C j ={C A, C B, C C, }. If the sequence of capacitance values is totally at random α=0.5 (white noise), the electrical transmission line is in the non-conducting state for every frequency ω. When we introduce long-range correlations in the distribution of capacitances, the electrical transmission lines can change their conducting properties and we can find a transition from the non-conducting to conducting state for a fixed system size. This implies the existence of critical values of the map parameters for each correlation exponent α. By performing finite-size scaling we obtain the asymptotic value of the map parameters in the thermodynamic limit for any α. With these data we obtain a phase diagram for the symmetric ternary model, which separates the non-conducting state from the conducting one. This is the fundamental result of this Letter. In addition, introducing one or more impurities in random places of the long-range correlated distribution of capacitances, we observe a dramatic change in the conducting properties of the electrical transmission lines, in such a way that the system jumps from conducting to non-conducting states. We think that this behavior can be considered as a possible mechanism to secure communication.

  12. Protonium spectrosopy and identification of P-wave and S-wave initial states of p-p annihilations at rest with the ASTERIX experiment at LEAR

    International Nuclear Information System (INIS)

    Gastaldi, U.; Ahmad, S.; Amsler, C.

    1984-01-01

    This chapter discusses an experiment designed to study the general features of p - p interactions at rest, to extend work done in the spectroscopy of light mesons produced in p - p annihilations at rest, and to search with high sensitivity for gluonium, qq - qq baryonium structures and NN states bound by strong interactions. The effect of using a gas target and a large acceptance X-ray detector is examined. The rate and the signature of antiprotons stopping in the gas target are investigated. Topics covered include the protonium cascade and spectroscopy; a comparison of S-wave and P-wave p - p annihilations at rest; - p stop and the formation of p - p atoms; the x-ray detector (projection chamber, electronics, tests); and examples of estimations of signal and background (protonium spectroscopy, search of resonances in P-wave annihilations, search of resonances in S-wave annihilations). The distinctive features of the ASTERIX experiment are the use of a gaseous H 2 target instead of a conventional liquid H 2 one; an X-ray detector of large overall detection efficiency, low energy threshold and low background rate that enables identification of P-wave and S-wave annihilation events from 2P and 1S levels of protonium; a detection system for the products of p - p annihilations; and a trigger system that enables filtration of the acquisition of events by means of two independent chains of processors working in parallel

  13. [Intravenous nitroglycerin infusion suppresses exercise-induced arrhythmia in patients with ischemic cardiopathy: indications for chronic treatment ].

    Science.gov (United States)

    Bonetti, F; Margonato, A; Mailhac, A; Vicedomini, G; Cianflone, D; Scarpazza, P; Chierchia, S L

    1990-05-01

    In patients with ischemic heart disease and arrhythmias, selection of antiarrhythmic treatment is often difficult as it is hard to separate "primary" from ischemic arrhythmias. We studied 20 patients with ischemic heart disease, who developed ventricular arrhythmias consistently during exercise test. Exercise test was performed twice during infusion of placebo and then during intravenous administration of nitroglycerin, titrated to reduce systolic blood pressure by 10 mmHg. Exercise duration was 7.8 +/- 1.7 and 7.9 +/- 1.5 min, in the 2 placebo tests (NS). Angina developed in 5 patients and ischemic ST changes in 10. With nitroglycerin exercise duration increased to 8.4 +/- 20 min (p less than 0.05), diagnostic ST segment depression was observed in 2 patients and only 1 had angina. In all 20 patients, ventricular arrhythmias were consistently present during both tests on placebo, that were markedly reduced by nitroglycerin. In fact, ventricular ectopic beats were 455 (mean 35.8 +/- 16.8) and 418 (mean 34.4 +/- 11.1) in the 2 exercise tests with placebo, and 11 during nitroglycerin infusion (mean 0.6 +/- 0.1; p less than 0.001). Couplets were 28 and 29 during placebo (NS) and 0 during nitroglycerin (p less than 0.001). Ventricular tachycardia was present in 6 and 8 patients during placebo but in none during nitroglycerin (p less than 0.001). Reduction of exercise-induced arrhythmias was maintained during chronic treatment with oral vasodilators. Prevention of exercise-related arrhythmias by nitroglycerin infusion appears a good indicator of their ischemic origin and may provide valuable information for long-term profilaxis with oral vasodilators, then avoiding the use of antiarrhythmic agents and their potential side effects.

  14. Scanning Electron Microscopy of Nonconductive Specimens at Critical Energies in a Cathode Lens System

    Czech Academy of Sciences Publication Activity Database

    Frank, Luděk; Zadražil, Martin; Müllerová, Ilona

    2001-01-01

    Roč. 23, č. 1 (2001), s. 36-50 ISSN 0161-0457 R&D Projects: GA ČR GA202/96/0961; GA ČR GA202/99/0008 Institutional research plan: CEZ:AV0Z2065902 Keywords : scanning electron microscopy * specimen charging * nonconductive specimens Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.389, year: 2001

  15. Alcohol, cardiac arrhythmias and sudden death.

    Science.gov (United States)

    Kupari, M; Koskinen, P

    1998-01-01

    Studies in experimental animals have shown varying and apparently opposite effects of alcohol on cardiac rhythm and conduction. Given acutely to non-alcoholic animals, ethanol may even have anti-arrhythmic properties whereas chronic administration clearly increases the animals' susceptibility to cardiac arrhythmias. Chronic heavy alcohol use has been incriminated in the genesis of cardiac arrhythmias in humans. The evidence has come from clinical observations, retrospective case-control studies, controlled studies of consecutive admissions for arrhythmias, and prospective epidemiological investigations. Furthermore, electrophysiological studies have shown that acute alcohol administration facilitates the induction of tachyarrhythmias in selected heavy drinkers. The role of alcohol appears particularly conspicuous in idiopathic atrial fibrillation. Occasionally, ventricular tachyarrhythmias have also been provoked by alcohol intake. Several lines of evidence suggest that heavy drinking increases the risk of sudden cardiac death with fatal arrhythmia as the most likely mechanism. According to epidemiological studies this effect appears most prominent in middle-aged men and is only partly explained by confounding traits such as smoking and social class. The basic arrhythmogenic effects of alcohol are still insufficiently delineated. Subclinical heart muscle injury from chronic heavy use may be instrumental in producing patchy delays in conduction. The hyperadrenergic state of drinking and withdrawal may also contribute, as may electrolyte abnormalities, impaired vagal heart rate control, repolarization abnormalities with prolonged QT intervals and worsening of myocardial ischaemia or sleep apnoea. Most of what we know about alcohol and arrhythmias relates to heavy drinking. The effect of social drinking on clinical arrhythmias in non-alcoholic cardiac patients needs to be addressed further.

  16. Arrhythmia risk in liver cirrhosis

    Institute of Scientific and Technical Information of China (English)

    Ioana Mozos

    2015-01-01

    Interactions between the functioning of the heart andthe liver have been described, with heart diseasesaffecting the liver, liver diseases affecting the heart,and conditions that simultaneously affect both. Theheart is one of the most adversely affected organs inpatients with liver cirrhosis. For example, arrhythmiasand electrocardiographic changes are observed inpatients with liver cirrhosis. The risk for arrhythmia isinfluenced by factors such as cirrhotic cardiomyopathy,cardiac ion channel remodeling, electrolyte imbalances,impaired autonomic function, hepatorenal syndrome, metabolic abnormalities, advanced age, inflammatory syndrome, stressful events, impaired drug metabolism and comorbidities. Close monitoring of cirrhotic patients is needed for arrhythmias, particularly when QT intervalprolonging drugs are given, or if electrolyte imbalances or hepatorenal syndrome appear. Arrhythmia risk may persist after liver transplantation due to possible QT interval prolongation, persistence of the parasympathetic impairment, post-transplant reperfusion and chronic immunosuppression, as well as consideration of the fact that the transplant itself is a stressful event for the cardiovascular system. The aims of the present article were to provide a review of the most important data regarding the epidemiology, pathophysiology, and biomarkers of arrhythmia risk in patients with liver cirrhosis, to elucidate the association with long-term outcome, and to propose future research directions.

  17. The risk of arrhythmias following coronary artery bypass surgery: do smokers have a paradox effect?

    LENUS (Irish Health Repository)

    Al-Sarraf, Nael

    2010-11-01

    Smoking is reported to increase the risk of arrhythmias. However, there are limited data on its effects on arrhythmias following coronary artery bypass graft (CABG). This is a retrospective review of a prospective database of all CABG patients over an eight-year period. Our cohort (n=2813) was subdivided into: current (n=1169), former (n=837), and non-smokers (n=807). Predictors of arrhythmias following CABG in relation to smoking status were analysed. Atrial arrhythmias occurred in 942 patients (33%). Ventricular arrhythmias occurred in 48 patients (2%) and high-grade atrioventricular block occurred in five patients (0.2%). Arrhythmias were lower in current smokers than former and non-smokers (29% vs. 40% vs. 39%, respectively P<0.001). Logistic regression analysis showed 30% arrhythmia risk reduction in smokers compared to non-smokers [odds ratio (OR) 0.7, 95% confidence intervals (CI) 0.5-0.8] and this effect persisted after accounting for potential confounders while former smokers had the same risk as non-smokers (OR 1.04, CI 0.9-1.3). There were no significant differences in mortality. Smokers are less prone to develop arrhythmias following CABG. This paradox effect is lost in former smokers. This effect is possibly due to a lower state of hyper adrenergic stimulation observed in smokers than non-smokers following the stress of surgery.

  18. Method of forming electronically conducting polymers on conducting and nonconducting substrates

    Science.gov (United States)

    Murphy, Oliver J. (Inventor); Hitchens, G. Duncan (Inventor); Hodko, Dalibor (Inventor); Clarke, Eric T. (Inventor); Miller, David L. (Inventor); Parker, Donald L. (Inventor)

    2001-01-01

    The present invention provides electronically conducting polymer films formed from photosensitive formulations of pyrrole and an electron acceptor that have been selectively exposed to UV light, laser light, or electron beams. The formulations may include photoinitiators, flexibilizers, solvents and the like. These solutions can be used in applications including printed circuit boards and through-hole plating and enable direct metallization processes on non-conducting substrates. After forming the conductive polymer patterns, a printed wiring board can be formed by sensitizing the polymer with palladium and electrolytically depositing copper.

  19. Arrhythmias in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Gaurav Agarwal

    2017-01-01

    Full Text Available Chronic hyperglycaemia of Type 2 diabetes mellitus causes long term damage to heart resulting in coronary artery disease (CAD, myocardial infarction (MI, congestive heart failure (CHF, and sudden death from arrhythmias. AIMS: To study the prevalence of different types of arrhythmias in T2DM, particularly in association with Cardiac Autonomic Neuropathy (CAN. METHODS: A cross-sectional study including 100 patients of Type 2 Diabetes Mellitus (T2DM presenting with cardiac arrhythmias, was done at our hospital over 2 years. Detailed history along with physical examination and tests for CAN were done. Routine investigations along with echocardiography, stress test, Holter monitoring were done. RESULTS: Sinus Tachycardia (ST was the commonest arrhythmia, found in 32% of patients. 20% had Complete Heart Block (CHB, 15% had Sinus Bradycardia (SB, and 15% had Atrial Fibrillation (AF. Ventricular Premature Complex (VPC was found in 10% and 3% had Atrial Premature Complex (APC. 3% had first degree AV block, whereas 1% had Paroxysmal Supra Ventricular Tachycardia (PSVT, and another 1% had Ventricular Tachycardia (VT. Poorly controlled diabetes and co-morbidities was associated with higher incidence of arrhythmias. 62% of patients had prolonged QTc, majority of which had CAN. Most of the patients responded to standard therapy.

  20. Arrhythmia and exercise intolerance in Fontan patients

    DEFF Research Database (Denmark)

    Idorn, L; Juul, K; Jensen, A S

    2013-01-01

    BACKGROUND: Long-term survival after the Fontan procedure shows excellent results but is associated with a persistent risk of arrhythmias and exercise intolerance. We aimed to analyze the current burden of clinically relevant arrhythmia and severe exercise intolerance in Danish Fontan patients...... and estimated to 99.1% per year. Prevalence of clinically relevant arrhythmia and severe exercise intolerance increased significantly with age and was found in 32% and 85% of patients ≥20years, respectively. Thus, from survival data and logistic regression models the future prevalence of patients, clinically...... relevant arrhythmia and severe exercise intolerance were estimated, revealing a considerable augmentation. Furthermore, resting and maximum cardiac index, resting stroke volume index and pulmonary diffusing capacity decreased significantly with age while diastolic and systolic ventricular function...

  1. Burden of arrhythmia in recreational marijuana users.

    Science.gov (United States)

    Desai, Rupak; Patel, Upenkumar; Deshmukh, Abhishek; Sachdeva, Rajesh; Kumar, Gautam

    2018-03-27

    Marijuana or Cannabis is extensively used as a recreational substance globally. Case reports have reported cardiac arrhythmias immediately following recreational marijuana use. However, the burden of arrhythmias in hospitalized marijuana users have not been evaluated through prospective or cross-sectional studies. Therefore, we planned to measure temporal trends of the frequency of arrhythmias in hospitalized marijuana users using National Inpatient Sample (NIS) database in the United States. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A Method for Coupling a Direct Current Power Source Across a Dielectric Membrane or Other Non-Conducting Membrane

    National Research Council Canada - National Science Library

    Steinbrecher, Donald H

    2008-01-01

    .... A second set of plates on the second side of the membrane form a set of coupling capacitors wherein the non-conducting dielectric membrane becomes part of the coupling-capacitor dielectric material...

  3. Immediate postoperative digitalization in the prophylaxis of supraventricular arrhythmias following coronary artery bypass.

    Science.gov (United States)

    Csicsko, J F; Schatzlein, M H; King, R D

    1981-03-01

    Regimens of acute preoperative digitalization have been evaluated previously in the prophylaxis of supraventricular tachycardias (SVT) following coronary artery bypass operations, with equivocal results. This study assesses the effectiveness of immediate postoperative digitalization on the incidence of arrhythmias in 407 consecutive patients recovering from myocardial revascularization. In 137 patients treated by our regimen, which begins digitalization within 4 hours postoperatively, the incidence of supraventricular tachyarrhythmias was 2%, while the corresponding figure for 270 untreated patients was 15%. Digitalization reduced the incidence of supraventricular arrhythmias significantly (p less than 0.01), whereas death, ventricular ectopy, and infarction rates were similar in the two groups. The few patients who did have supraventricular arrhythmias while receiving prophylactic digoxin were no more easily treated than patients in the undigitalized group. The timing of administration of digoxin for SVT prophylaxis may be more important than previously recognized. Immediately postoperative digitalization, theoretically preferable to preoperative regimens, is a safe, effective way to reduce the incidence of supraventricular arrhythmias following myocardial revascularization.

  4. Metabolic Syndrome Remodels Electrical Activity of the Sinoatrial Node and Produces Arrhythmias in Rats

    Science.gov (United States)

    Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia

    2013-01-01

    In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of “metabolic syndrome rats”, compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats. PMID:24250786

  5. Scaling properties of conduction velocity in heterogeneous excitable media

    Science.gov (United States)

    Shajahan, T. K.; Borek, Bartłomiej; Shrier, Alvin; Glass, Leon

    2011-10-01

    Waves of excitation through excitable media, such as cardiac tissue, can propagate as plane waves or break up to form reentrant spiral waves. In diseased hearts reentrant waves can be associated with fatal cardiac arrhythmias. In this paper we investigate the conditions that lead to wave break, reentry, and propagation failure in mathematical models of heterogeneous excitable media. Two types of heterogeneities are considered: sinks are regions in space in which the voltage is fixed at its rest value, and breaks are nonconducting regions with no-flux boundary conditions. We find that randomly distributed heterogeneities in the medium have a decremental effect on the velocity, and above a critical density of such heterogeneities the conduction fails. Using numerical and analytical methods we derive the general relationship among the conduction velocity, density of heterogeneities, diffusion coefficient, and the rise time of the excitation in both two and three dimensions. This work helps us understand the factors leading to reduced propagation velocity and the formation of spiral waves in heterogeneous excitable media.

  6. Cardiac arrhythmia as initial presentation of aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    van der Kleij, FGH; Henselmans, JML; van de Loosdrecht, AA

    1999-01-01

    Cardiac arrhythmia and sudden death are most frequently caused by preexisting heart disease. Rarely, cardiac arrhythmia is a first symptom of an acute neurological event. We describe a patient with asystole and other cardiac arrhythmias, as initial symptoms of acute aneurysmal subarachnoid

  7. Obstructive sleep apnoea-hypopnoea and arrhythmias: new updates.

    Science.gov (United States)

    Vizzardi, Enrico; Sciatti, Edoardo; Bonadei, Ivano; D'Aloia, Antonio; Curnis, Antonio; Metra, Marco

    2017-07-01

    Obstructive sleep apnoea-hypopnoea (OSAH) is a prevalent condition characterized by repetitive pharyngeal collapse during sleep, leading to hypoxemia, hypercapnia, and persistent inspiratory efforts against an occluded airway until arousal. Several studies demonstrated that OSAH exerts acute and chronic effects on the cardiovascular system. Thus, although being a respiratory problem, the most important consequences of OSAH are cardiovascular, among which there are arrhythmias. The purpose of this review is to systematically analyse what has been recently published about the relationship between OSAH and every cardiac arrhythmia separately. We searched Pubmed, Scopus, Web of Science and Cochrane Collaboration databases for 'OSAHS arrhythmias', 'OSAH arrhythmias' and 'OSA arrhythmias'. We analyse 1298 articles and meta-analyses, excluding already edited reviews. Arrhythmias, especially of ventricular origin, are frequent in OSAH. Ventricular premature beats, couplets and ventricular tachycardia runs are even more frequent in patients suffering from heart failure. They may be due to left heart remodelling, overwork and ischaemia and can explain at least some sudden deaths occurring between midnight and 6 a.m. Sinus pauses and atrioventricular blocks are increased according to the severity of the disturbance and may be reduced by continuous positive airway pressure therapy, preventing pace-maker implantation. Finally, atrial fibrillation, resistance against antiarrhythmic drugs and recurrences after surgical procedures are strongly related to OSAH. Arrhythmias are frequent in OSAH. Treatment of OSAH may reduce some of them. An implantable cardioverter-defibrillator and continuous positive airway pressure should be considered in some patients.

  8. Quasiparticle Green's function theory of the Josephson effect in chiral p-wave superconductor/diffusive normal metal/chiral p-wave superconductor junctions

    NARCIS (Netherlands)

    Sawa, Y.; Yokoyama, T.; Tanaka, Y.; Golubov, Alexandre Avraamovitch

    2007-01-01

    We study the Josephson effect in chiral p-wave superconductor/diffusive normal metal (DN)/chiral p-wave superconductor (CP/DN/CP) junctions using quasiclassical Green's function formalism with proper boundary conditions. The px+ipy-wave symmetry of superconducting order parameter is chosen which is

  9. Non-conductive ferromagnetic carbon-coated (Co, Ni) metal/polystyrene nanocomposites films

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, H., E-mail: helene.takacs@gmail.com [CEA, LETI, MINATEC Campus, Grenoble 38054 (France); LTM-CNRS-UJF, CEA, LETI, Minatec Campus, Grenoble 38054 (France); Viala, B.; Hermán, V. [CEA, LETI, MINATEC Campus, Grenoble 38054 (France); Tortai, J.-H. [LTM-CNRS-UJF, CEA, LETI, Minatec Campus, Grenoble 38054 (France); Duclairoir, F. [Université Grenoble Alpes, INAC, Grenoble 38054 (France); CEA, INAC, Grenoble 38054 (France)

    2016-03-07

    This article reports non-conductive ferromagnetic properties of metal/polymer nanocomposite films intended to be used for RF applications. The nanocomposite arrangement is unique showing a core double-shell structure of metal-carbon-polystyrene: M/C//P{sub 1}/P{sub 2}, where M = Co, Ni is the core material, C = graphene or carbon is the first shell acting as a protective layer against oxidation, P{sub 1} = pyrene-terminated polystyrene is the second shell for electrical insulation, and P{sub 2} = polystyrene is a supporting matrix (// indicates actual grafting). The nanocomposite formulation is briefly described, and the film deposition by spin-coating is detailed. Original spin-curves are reported and analyzed. One key outcome is the achievement of uniform and cohesive films at the wafer scale. Structural properties of films are thoroughly detailed, and weight and volume fractions of M/C are considered. Then, a comprehensive overview of DC magnetic and electrical properties is reported. A discussion follows on the magnetic softness of the nanocomposites vs. that of a single particle (theoretical) and the raw powder (experimental). Finally, unprecedented achievement of high magnetization (∼0.6 T) and ultra-high resistivity (∼10{sup 10 }μΩ cm) is shown. High magnetization comes from the preservation of the existing protective shell C, with no significant degradation on the particle net-moment, and high electrical insulation is ensured by adequate grafting of the secondary shell P{sub 1}. To conclude, the metal/polymer nanocomposites are situated in the landscape of soft ferromagnetic materials for RF applications (i.e., inductors and antennas), by means of two phase-diagrams, where they play a crucial role.

  10. A model of cardiac ryanodine receptor gating predicts experimental Ca2+-dynamics and Ca2+-triggered arrhythmia in the long QT syndrome

    Science.gov (United States)

    Wilson, Dan; Ermentrout, Bard; Němec, Jan; Salama, Guy

    2017-09-01

    Abnormal Ca2+ handling is well-established as the trigger of cardiac arrhythmia in catecholaminergic polymorphic ventricular tachycardia and digoxin toxicity, but its role remains controversial in Torsade de Pointes (TdP), the arrhythmia associated with the long QT syndrome (LQTS). Recent experimental results show that early afterdepolarizations (EADs) that initiate TdP are caused by spontaneous (non-voltage-triggered) Ca2+ release from Ca2+-overloaded sarcoplasmic reticulum (SR) rather than the activation of the L-type Ca2+-channel window current. In bradycardia and long QT type 2 (LQT2), a second, non-voltage triggered cytosolic Ca2+ elevation increases gradually in amplitude, occurs before overt voltage instability, and then precedes the rise of EADs. Here, we used a modified Shannon-Puglisi-Bers model of rabbit ventricular myocytes to reproduce experimental Ca2+ dynamics in bradycardia and LQT2. Abnormal systolic Ca2+-oscillations and EADs caused by SR Ca2+-release are reproduced in a modified 0-dimensional model, where 3 gates in series control the ryanodine receptor (RyR2) conductance. Two gates control RyR2 activation and inactivation and sense cytosolic Ca2+ while a third gate senses luminal junctional SR Ca2+. The model predicts EADs in bradycardia and low extracellular [K+] and cessation of SR Ca2+-release terminate salvos of EADs. Ca2+-waves, systolic cell-synchronous Ca2+-release, and multifocal diastolic Ca2+ release seen in subcellular Ca2+-mapping experiments are observed in the 2-dimensional version of the model. These results support the role of SR Ca2+-overload, abnormal SR Ca2+-release, and the subsequent activation of the electrogenic Na+/Ca2+-exchanger as the mechanism of TdP. The model offers new insights into the genesis of cardiac arrhythmia and new therapeutic strategies.

  11. Noninvasive predictors of perioperative atrial arrhythmias in patients with tetralogy of Fallot undergoing pulmonary valve replacement.

    Science.gov (United States)

    Cortez, Daniel; Barham, Waseem; Ruckdeschel, Emily; Sharma, Nandita; McCanta, Anthony C; von Alvensleben, Johannes; Sauer, William H; Collins, Kathryn K; Kay, Joseph; Patel, Sonali; Nguyen, Duy T

    2017-08-01

    Patients with tetralogy of Fallot (TOF) have increased risk of atrial arrhythmias. A measure of atrial dispersion, the P-wave vector magnitude (Pvm), can identify patients at risk for perioperative atrial flutter (AFL) or intra-atrial re-entrant tachycardia (IART) in a large TOF cohort. We performed a blinded, retrospective analysis of 158 TOF patients undergoing pulmonary valve replacement between 1997 and 2015. History of AFL/IART was documented using electrocardiogram, Holter monitor, exercise stress test, implanted cardiac device, and electrophysiology study. P-R intervals, Pvm, QRS duration, and QRS vector magnitude were assessed from resting sinus-rhythm 12-lead electrocardiograms and identification of those with AFL/IART was determined. Fourteen patients (8.9%) were found to have AFL/IART. Pvm, QRS duration, and QRS vector magnitude significantly differentiated those with AFL/IART from those without on univariate analysis: 0.09 ± 0.04 vs 0.18 ± 0.07 mV, 161.3 ± 21.9 vs 137.7 ± 31.4 ms, and 1.2 (interquartile range, 1.0-1.2) vs 1.6 mV (1.0-2.3), respectively (P < 0.05 for each). The Pvm had the highest area under the ROC curve (0.88) and was the only significant predictor on multivariate analysis, with odds ratio of 0.02 (95% confidence interval: 0.01-0.53). P-R duration, MRI volumes, and right-heart hemodynamics did not significantly differentiate those with vs those without AFL/IART. In TOF patients undergoing pulmonary valve replacement, Pvm has significant value in predicting those with perioperative AFL/IART. These clinical features may help further evaluate TOF patients at risk for perioperative atrial arrhythmias. Prospective studies are warranted. © 2017 Wiley Periodicals, Inc.

  12. Magnesium sulphate and amiodarone prophylaxis for prevention of postoperative arrhythmia in coronary by-pass operations

    Directory of Open Access Journals (Sweden)

    Huysal Kagan

    2009-02-01

    Full Text Available Abstract Background The aim of this study was to investigate the use of prophylactic magnesium sulphate and amiodarone in treating arrhythmias that may occur following coronary bypass grafting operations. Methods The study population consisted of 192 consecutive patients who were undergoing coronary artery bypass grafting (CABG. Sixty-four patients were given 3 g of magnesium sulphate (MgSO4 [20 ml = 24.32 mEq/L Mg+2] in 100 cc of isotonic 0.9% solution over 2 hours intravenously at the following times: 12 hours prior to the operation, immediately following the operation, and on postoperative days 1, 2, and 3 (Group 1. Another group of 64 patients was given a preoperative infusion of amiodarone (1200 mg on first post-operative day (Group 2. After the operation amiodarone was administered orally at a dose of 600 mg/day. Sixty-four patients in group 3 (control group had 100 cc. isotonic 0.9% as placebo, during the same time periods. Results In the postoperative period, the magnesium values were significantly higher in Group 1 than in Group 2 for all measurements. The use of amiodarone for total arrhythmia was significantly more effective than prophylactic treatment with magnesium sulphate (p = 0.015. There was no difference between the two drugs in preventing supraventricular arrhythmia, although amiodarone significantly delayed the revealing time of atrial fibrillation (p = 0.026. Ventricular arrhythmia, in the form of ventricular extra systole, was more common in the magnesium prophylaxis group. The two groups showed no significant differences in other operative or postoperative measurements. No side effects of the drugs were observed. Conclusion Prophylactic use of magnesium sulphate and amiodarone are both effective at preventing arrhythmia that may occur following coronary by-pass operations. Magnesium sulphate should be used in prophylactic treatment since it may decrease arrhythmia at low doses. If arrhythmia should occur despite this

  13. Chaos for cardiac arrhythmias through a one-dimensional modulation equation for alternans

    Science.gov (United States)

    Dai, Shu; Schaeffer, David G.

    2010-01-01

    Instabilities in cardiac dynamics have been widely investigated in recent years. One facet of this work has studied chaotic behavior, especially possible correlations with fatal arrhythmias. Previously chaotic behavior was observed in various models, specifically in the breakup of spiral and scroll waves. In this paper we study cardiac dynamics and find spatiotemporal chaotic behavior through the Echebarria–Karma modulation equation for alternans in one dimension. Although extreme parameter values are required to produce chaos in this model, it seems significant mathematically that chaos may occur by a different mechanism from previous observations. PMID:20590327

  14. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  15. Cardiac arrhythmias in adult patients with asthma

    DEFF Research Database (Denmark)

    Warnier, Miriam J; Rutten, Frans H; Kors, Jan A

    2012-01-01

    OBJECTIVE: The pathogenesis of cardiac arrhythmias in asthma patients has not been fully elucidated. Adverse drug effects, particularly those of β2-mimetics, may play a role. The aim of this study was to determine whether asthma is associated with the risk of cardiac arrhythmias and electrocardio......OBJECTIVE: The pathogenesis of cardiac arrhythmias in asthma patients has not been fully elucidated. Adverse drug effects, particularly those of β2-mimetics, may play a role. The aim of this study was to determine whether asthma is associated with the risk of cardiac arrhythmias...... and electrocardiographic characteristics of arrhythmogenicity (ECG) and to explore the role of β2-mimetics. METHODS: A cross-sectional study was conducted among 158 adult patients with a diagnosis of asthma and 6303 participants without asthma from the cohort of the Utrecht Health Project-an ongoing, longitudinal, primary...... or flutter). Secondary outcomes were tachycardia, bradycardia, PVC, atrial fibrillation or flutter, mean heart rate, mean corrected QT (QTc) interval length, and prolonged QTc interval. RESULTS: Tachycardia and PVCs were more prevalent in patients with asthma (3% and 4%, respectively) than those without...

  16. QTc-prolonging drugs and hospitalizations for cardiac arrhythmias

    DEFF Research Database (Denmark)

    De Bruin, Marie L; Hoes, Arno W; Leufkens, Hubert G M

    2003-01-01

    Cardiac arrhythmia as an adverse effect of noncardiac drugs has been an issue of growing importance during the past few years. In this population-based study, we evaluated the risk for serious cardiac arrhythmias during the use of several noncardiac QTc-prolonging drugs in day-to-day practice......, and subsequently focused on several specific groups of patients who could be extremely vulnerable for drug-induced arrhythmias. We performed a case-control study in which patients (cases), hospitalized for nonatrial cardiac arrhythmias from 1987 to 1998, were compared with their matched controls regarding current...... use of QTc-prolonging drugs. Odds ratios (OR) and 95% confidence intervals (CI) were calculated using multivariate conditional logistic regression, adjusting for potential confounding factors. Data were obtained from the PHARMO record linkage system. We identified 501 cases, 39 of whom used QTc...

  17. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Tassi, Eduardo Marinho, E-mail: etassi@ibest.com.br [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Continentino, Marcelo Abramoff [Hospital Frei Galvão, Guaratinguetá, SP (Brazil); Nascimento, Emília Matos do; Pereira, Basílio de Bragança [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Coppe - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - UFRJ, Rio de Janeiro, RJ (Brazil); Pedrosa, Roberto Coury [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2014-05-15

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups.

  18. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    International Nuclear Information System (INIS)

    Tassi, Eduardo Marinho; Continentino, Marcelo Abramoff; Nascimento, Emília Matos do; Pereira, Basílio de Bragança; Pedrosa, Roberto Coury

    2014-01-01

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups

  19. Holographic p-wave superconductor models with Weyl corrections

    Directory of Open Access Journals (Sweden)

    Lu Zhang

    2015-04-01

    Full Text Available We study the effect of the Weyl corrections on the holographic p-wave dual models in the backgrounds of AdS soliton and AdS black hole via a Maxwell complex vector field model by using the numerical and analytical methods. We find that, in the soliton background, the Weyl corrections do not influence the properties of the holographic p-wave insulator/superconductor phase transition, which is different from that of the Yang–Mills theory. However, in the black hole background, we observe that similarly to the Weyl correction effects in the Yang–Mills theory, the higher Weyl corrections make it easier for the p-wave metal/superconductor phase transition to be triggered, which shows that these two p-wave models with Weyl corrections share some similar features for the condensation of the vector operator.

  20. Electrical Signs predictors of malignant ventricular arrhythmias

    International Nuclear Information System (INIS)

    Aleman Fernandez, Ailema Amelia; Dorantes Sanchez, Margarita

    2012-01-01

    Recurrence of malignant ventricular arrhythmia is frequent in cardioverter-defibrillators related patients. The risk stratification is difficult, there are numerous electrocardiographic predictors but his sensibility and specificity are not absolute. The limit between normal and pathological is not defined, besides the complexity of ventricular arrhythmias. We expose different electrocardiographic predictors that can help to better individual risk stratification

  1. Late gadolinium enhancement by magnetic resonance explains adverse cardiac events in individuals with ventricular arrhythmia

    International Nuclear Information System (INIS)

    Courtis, J.; Vasallo, J.; Arabia, L.; Dimitroff, M.; Gonzalez, A.; Tibaldi, M.

    2012-01-01

    Objective: To determine whether the presence of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) predict adverse cardiac events in patients with ventricular arrhythmia. Methods: We selected 74 consecutive patients with symptomatic ventricular arrhythmia (premature ventricular contractions and ventricular tachycardia) and left ventricular ejection fraction (LVEF) >55% sent to CMR for evaluation of structural heart disease previously undetected by other complementary methods. LGE, systolic function and volumes of both ventricles were analyzed. At follow-up was assessed a combined end point: hospitalization for ventricular arrhythmia, appropriate implantable cardioverter-defibrillator therapy and cardiac death. Results: During a median follow up of 575 days (interquartile range 24-1120 days) and by analyzing the population according to the presence (n=9, 12%) or not (n=65, 88%) LGE was observed that the group with positive Gd had lower LVEF (58% vs. 66% respectively, p=0.01) and larger volumes (EDV: 185 ml vs. 123 ml respectively, p=0.01 and ESV: 81 ml vs. 42 ml respectively, p=0.01) than the other group. Two (22%) patients in the LGE + group vs. one (4%) of those without LGE showed the combined endpoint (p=0.01) and when performing a logistic regression analysis it was found that the LGE is a predictor of adverse cardiac events analyzed (p=0.029). Conclusions: In this consecutive series of patients with ventricular arrhythmia we demonstrate a strong association between myocardial LGE and adverse cardiac events; this supports the hypothesis that myocardial fibrosis is an important arrhythmogenic substrate. In addition, almost all individuals without LGE were free of events during follow-up suggesting that it is possible to identify through the CMR low-risk individuals who can be treated conservatively. (authors) [es

  2. P-S & S-P Elastic Wave Conversions from Linear Arrays of Oriented Microcracks

    Science.gov (United States)

    Jiang, L.; Modiriasari, A.; Bobet, A.; Pyrak-Nolte, L. J.

    2017-12-01

    Natural and induced processes can produce oriented mechanical discontinuities such as en echelon cracks, fractures and faults. Previous research has shown that compressional to shear (P-S) wave conversions occur at normal incidence to a fracture because of cross-coupling fracture compliances (Nakagawa et al., 2000). Here, experiments and computer simulation are presented to demonstrate the link among cross-coupling stiffness, microcrack orientation and energy partitioning among P, S, and P-S/S-P waves. A FormLabs 2 3D printer was used to fabricate 7 samples (50 mm x 50 mm x 100 mm) with linear arrays of microcracks oriented at 0, 15, 30, 45, 60, 75, and 900 with a print resolution of 0.025 mm. The microcracks were elliptical in cross-sections (2 mm long by 1 mm wide), through the 50 mm thickness of sample, and spaced 3 mm (center-to-center for adjacent cracks). A 25 mm length of each sample contained no microcracks to act as a reference material. Broadband transducers (0.2-1.5 MHz) were used to transmit and receive P and polarized S wave signals that were propagated at normal incidence to the linear array of microcracks. P-wave amplitude increased, while S-wave amplitude remained relatively constant, as the microcrack orientation increased from 0o to 90o. At normal incidence, P-S and S-P wave conversions emerged and increased in amplitude as the crack inclination increased from 00 to 450. From 450 to 900, the amplitude of these converted modes decreased. Between negative and positive crack angles, the P-to-S and S-to-P waves were 1800 phase reversed. The observed energy partitioning matched the computed compliances obtained from numerical simulations with ABAQUS. The cross-coupling compliance for cracks inclined at 450 was found to be the smallest magnitude. 3D printing enabled the study of microstructural effects on macro-scale wave measurements. Information on the orientation of microcracks or even en echelon fractures and faults is contained in P-S conversions

  3. [Idiopathic ventricular arrhythmia in children. Apropos of 24 cases].

    Science.gov (United States)

    Coeurderoy, A; Almange, C; Laurent, M; Biron, Y; Leborgne, P

    1985-12-01

    The severity and prognosis of idiopathic ventricular arrhythmias in childhood were studied in 24 patients (12 boys, 12 girls) with an average age of 8 years at the time of diagnosis of the arrhythmia. Investigations included clinical assessment and analysis of basal ECG (morphology of the arrhythmias) and dynamic recordings (Holter and exercise stress testing). The clinical course was followed for an average of 3.8 years. The patients were classified in two groups: monomorphic arrhythmias (Group I) and polymorphic arrhythmias (Group II). Group I was divided into 4 subgroups: isolated ventricular extrasystoles (IA), 11 patients; ventricular extrasystoles with bursts of ventricular tachycardia (IB), 6 patients; sustained ventricular tachycardia without intercritical extrasystoles (IC), 1 patient; accelerated idioventricular rhythm (ID), 2 patients. Subgroups IA, IB and ID were characterised by the absence of symptoms, the disappearance of the arrhythmia on exercise, the decreased efficacy of antiarrhythmic drugs and an excellent prognosis. Therapeutic abstention was the rule in these patients. Patients in Group IC were characterised by the variability of their symptoms, the absence of exercise induced arrhythmias, the need for treatment in most cases and a good long-term prognosis. Group II was divided into 2 subgroups: adrenergic polymorphic ventricular tachycardia (IIA), 2 patients, and non-adrenergic polymorphic ventricular tachycardia (IIB), 2 patients. Patients in Subgroup IIA were characterised by syncope on exercise or emotion, the need for betablocker therapy which considerably improved the patients symptoms but which did not usually prevent sudden death.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Arrhythmia-provoking factors and symptoms at the onset of paroxysmal atrial fibrillation: A study based on interviews with 100 patients seeking hospital assistance

    Directory of Open Access Journals (Sweden)

    Madsen-Härdig Bjarne

    2004-08-01

    Full Text Available Abstract Background Surprisingly little information on symptoms of paroxysmal atrial fibrillation is available in scientific literature. Using questionnaires, we have analyzed the symptoms associated with arrhythmia attacks. Methods One hundred randomly-selected patients with idiopathic paroxysmal atrial fibrillation filled in a structured questionnaire. Results Psychic stress was the most common factor triggering arrhythmia (54%, followed by physical exertion (42%, tiredness (41% coffee (25% and infections (22%. Thirty-four patients cited alcohol, 26 in the form of red wine, 16 as white wine and 26 as spirits. Among these 34, red wine and spirits produced significantly more episodes of arrhythmia than white wine (p = 0.01 and 0.005 respectively. Symptoms during arrhythmia were palpitations while exerting (88%, reduced physical ability (87%, palpitations at rest (86%, shortage of breath during exertion (70% and anxiety (59%. Significant differences between sexes were noted regarding swollen legs (women 21%, men 6%, p = 0.027, nausea (women 36%, men 13%, p = 0.012 and anxiety (females 79%, males 51%, p = 0.014. Conclusion Psychic stress was the commonest triggering factor in hospitalized patients with paroxysmal atrial fibrillation. Red wine and spirits were more proarrhythmic than white wine. Symptoms in women in connection with attacks of arrhythmia vary somewhat from those in men.

  5. Combination of opium smoking and hypercholesterolemia augments susceptibility for lethal cardiac arrhythmia and atherogenesis in rabbit.

    Science.gov (United States)

    Najafipour, Hamid; Joukar, Siyavash

    2012-09-01

    Opium consumption is increasing in some eastern societies, where it is grown. We investigated the effect of opium smoking on plasma atherogenic index and incidence of lethal cardiac arrhythmia, i.e. ventricular tachycardia (VT) and ventricular fibrillation (VF) in rabbits. Animals were divided into two-, normo- and hyper-cholesterolemic main groups fed with normal or high cholesterol diet prior and during short-term and long-term exposure to opium smoke. Then, isoproterenol (3mg/kg, i.p.) was injected to induce cardiac ischemia and animals were followed for 3h for counting of lethal arrhythmia incidence. Long-term opium smoking significantly increased the plasma atherogenic index. In ischemic hearts, opium smoking along with hypercholesterolemia significantly enhanced the incidence of fatal arrhythmia. This vulnerability was not mediated by changes in QT interval. These data suggest that opium smoking, especially in hypercholesterolemic conditions, can be a predisposing factor for atherogenesis and lethal arrhythmia. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Sensitivity analysis of P-waves and S-waves to gas hydrate in the Shenhu area using OBS

    Science.gov (United States)

    Xing, Lei; Liu, Xueqin; Zhang, Jin; Liu, Huaishan; Zhang, Jing; Li, Zizheng; Wang, Jianhua

    2018-02-01

    Compared to towed streamers, ocean-bottom seismometers (OBS) obtain both S-wave data and richer wavefield information. In this paper, the induced polarization method is used to conduct wavefield separation on OBS data obtained from the Shenhu area in the South China Sea. A comparison of the changes in P- and S-waves, and a comprehensive analysis of geological factors within the area, enable analysis and description of the occurrence of natural gas hydrate in the study area. Results show an increase in P-wave velocity when natural gas hydrate exists in the formation, whereas the S-wave velocity remains almost constant, as S-waves can only propagate through the rock skeleton. Therefore, the bottom-simulating reflection (BSR) response of the P-wave is better than that of the S-wave in the frequency analysis profile. In a wide-angle section, the refractive wave of the hydrate layer is evident when using P-wave components but identification is difficult with S-wave components. This velocity model illustrates the sensitivity of P- and S-wave components to gas hydrate. The use of this polarization method and results of analysis provide technical and theoretical support for research on hydrate deposits and other geological features in the Shenhu area.

  7. Qt interval prolongation and ventricular arrhythmias in patients with chronic heart failure

    International Nuclear Information System (INIS)

    Sarwar, M.; Majeed, S.M.I.; Khan, M.A.; Majeed, S.M.

    2014-01-01

    To determine the association of QTc interval prolongation with ventricular arrhythmias in patients with chronic heart failure. Study Design: Descriptive study. Place and Duration of Study: This study was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases, Rawalpindi, Pakistan from April 2013 to August 2013. Patients and Methods: Fifty three heart failure patients were monitored for 48 hours using ambulatory holter electrocardiography recorders. Digital ECG data was analyzed for QTc interval along with frequency and severity of arrhythmias. Association of prolonged QTc interval with ventricular arrhythmias and severity of arrhythmias was analyzed. Results: Cardiac arrhythmias were observed in 79.2% patients. QT analysis revealed that 69.8% patients had prolonged QTc interval, 86.4% patients with prolonged QTc had ventricular arrhythmias. Of these 66% patients were found to have severe ventricular arrhythmias. Comparison of mean QTc interval of our study population with a reference value showed significantly higher QTc interval of our study group than the test value. Conclusion: Arrhythmia frequency and severity significantly increases with an increase in QTc interval in heart failure demonstrating association of prolonged QTc interval with high risk of severe ventricular arrhythmias and sudden cardiac death in chronic heart failure. (author)

  8. QTc-prolonging drugs and hospitalizations for cardiac arrhythmias

    NARCIS (Netherlands)

    De Bruin, ML; Hoes, AW; Leufkens, HGM

    2003-01-01

    Cardiac arrhythmia as an adverse effect of noncardiac drugs has been an issue of growing importance during the past few years. In this population-based study, we evaluated the risk for serious cardiac arrhythmias during the use of several noncardiac QTc-prolonging drugs in day-to-day practice, and

  9. P Wave Dispersion is Increased in Pulmonary Stenosis

    Directory of Open Access Journals (Sweden)

    Namik Ozmen

    2006-01-01

    Full Text Available Aim: The right atrium pressure load is increased in pulmonary stenosis (PS that is a congenital anomaly and this changes the electrophysiological characteristics of the atria. However, there is not enough data on the issue of P wave dispersion (PWD in PS. Methods: Forty- two patients diagnosed as having valvular PS with echocardiography and 33 completely healthy individuals as the control group were included in the study. P wave duration, p wave maximum (p max and p minimum (p min were calculated from resting electrocariography (ECG obtained at the rate of 50 mm/sec. P wave dispersion was derived by subtracting p min from p max. The mean pressure gradient (MPG at the pulmonary valve, structure of the valve and diameters of the right and left atria were measured with echocardiography. The data from two groups were compared with the Mann-Whitney U test and correlation analysis was performed with the Pearson correlation technique. Results: There wasn’t any statistically significance in the comparison of age, left atrial diameter and p min between two groups. While the MPG at the pulmonary valve was 43.11 ± 18.8 mmHg in PS patients, it was 8.4 ± 4.5 mmHg in the control group. While p max was 107.1 ± 11.5 in PS group, it was 98.2 ± 5.1 in control group (p=0.01, PWD was 40.4 ± 1.2 in PS group, and 27.2 ± 9.3 in the control group (p=0.01Moreover, while the diameter of the right atrium in PS group was greater than that of the control group, (38.7 ± 3.9 vs 30.2 ± 2.5, p=0.02. We detected a correlation between PWD and pressure gradient in regression analysis. Conclusion: P wave dispersion and p max are increased in PS. While PWD was correlated with the pressure gradient that is the degree of narrowing, it was not correlated with the diameters of the right and left atria.

  10. Production of arrhythmias by elevated carboxyhemoglobin in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Sheps, D.S.; Herbst, M.C.; Hinderliter, A.L.; Adams, K.F.; Ekelund, L.G.; O'Neil, J.J.; Goldstein, G.M.; Bromberg, P.A.; Dalton, J.L.; Ballenger, M.N.

    1990-01-01

    The object of this study was to assess the effects of exposure to 4% and 6% carboxyhemoglobin on ventricular arrhythmias in patients with coronary artery disease. This was a randomized, double-blind, crossover design. Forty-one nonsmokers with documented coronary artery disease were tested. On day 1, a training session with no exposure, the baseline carboxyhemoglobin level was measured, and a supine bicycle exercise test was done. On days 2 to 4, patients were exposed to room air, 100 ppm carbon monoxide (target, 4% carboxyhemoglobin) or 200 ppm carbon monoxide (target, 6% carboxyhemoglobin), and they then did supine bicycle exercise with radionuclide ventriculography. Ambulatory electrocardiogram recordings were made during the 4 consecutive days to determine the frequency of ventricular premature depolarization (VPD) at various intervals. The frequency of single VPD/h was significantly greater on the 6% carboxyhemoglobin day than on the room air day during the exercise period (167.72 +/- 37.99 for 6% carboxyhemoglobin compared with 127.32 +/- 28.22 for room air, P = 0.03). During exercise, the frequency of multiple VPD/h was greater on the 6% carboxyhemoglobin day compared with room air (9.59 +/- 3.70 on the 6% carboxyhemoglobin compared with 3.18 +/- 1.67 on room air, P = 0.02). Patients who developed increased single VPD during exercise on the 6% carboxyhemoglobin day were significantly older than those who had no increased arrhythmia, whereas patients who developed complex arrhythmias were also older and, in addition, exercised longer and had a higher peak workload during exercise. The number and complexity of ventricular arrhythmias increases significantly during exercise after carbon monoxide exposure producing 6% carboxyhemoglobin compared with room air but not after exposure producing 4% carboxyhemoglobin

  11. Andrographolide inhibits arrhythmias and is cardioprotective in rabbits.

    Science.gov (United States)

    Zeng, Mengliu; Jiang, Wanzhen; Tian, Youjia; Hao, Jie; Cao, Zhenzhen; Liu, Zhipei; Fu, Chen; Zhang, Peihua; Ma, Jihua

    2017-09-22

    Andrographolide has a protective effect on the cardiovascular system. To study its cardic-electrophysiological effects, action potentials and voltage-gated Na + (I Na ), Ca 2+ (I CaL ), and K + (I K1 , I Kr , I to and I Kur ) currents were recorded using whole-cell patch clamp and current clamp techniques. Additionally, the effects of andrographolide on aconitine-induced arrhythmias were assessed on electrocardiograms in vivo . We found that andrographolide shortened action potential duration and reduced maximum upstroke velocity in rabbit left ventricular and left atrial myocytes. Andrographolide attenuated rate-dependence of action potential duration, and reduced or abolished delayed afterdepolarizations and triggered activities induced by isoproterenol (1 μM) and high calcium ([Ca 2+ ] o =3.6 mM) in left ventricular myocytes. Andrographolide also concentration-dependently inhibited I Na and I CaL , but had no effect on I to , I Kur , I K1 , or I Kr in rabbit left ventricular and left atrial myocytes. Andrographolide treatment increased the time and dosage thresholds of aconitine-induced arrhythmias, and reduced arrhythmia incidence and mortality in rabbits. Our results indicate that andrographolide inhibits cellular arrhythmias (delayed afterdepolarizations and triggered activities) and aconitine-induced arrhythmias in vivo , and these effects result from I Na and I CaL inhibition. Andrographolide may be useful as a class I and IV antiarrhythmic therapeutic.

  12. Covariant trace formalism for heavy meson s-wave to p-wave transitions

    International Nuclear Information System (INIS)

    Balk, S.; Koerner, J.G.; Thompson, G.; Hussain, F.

    1992-06-01

    Heavy meson, s- to p-wave, weak transitions are studied in the context of the Heavy Quark Effective Theory using covariant meson wave functions. We use the trace formalism to evaluate the weak transitions. As expected from heavy quark symmetry, the eight transitions between s- and p-wave states are described in terms of only two universal form factors which are given in terms of explicit wave function overlap integrals. We present our results in terms of both invariant and helicity amplitudes. Using our helicity amplitude expressions we discuss rate formulae, helicity structure functions and joint angular decay distributions in the decays B-bar→D**(→(D,D*)+π)+W - (→l - ν l ). The heavy quark symmetry predictions for the one-pion transitions D**→(D,D*)+π are similarly worked out by using trace techniques. (author). 35 refs, 3 figs, 2 tabs

  13. BAYESZ, S-Wave, P-Wave Resonance Level Spacing and Strength Functions

    International Nuclear Information System (INIS)

    Moore, M.S.

    1982-01-01

    A - Description of problem or function: BAYESZ calculates average s- and p-wave level spacings, strength functions, and average radiation widths of a mixed sequence of s- and p-wave resonances whose parameters are supplied as input. The code is based on two physical assumptions: 1) The neutron reduced width distribution for each open channel is a chi-squared distribution with one degree of freedom, i.e. Porter-Thomas. 2) The spacing distribution follows the Gaussian Orthogonal Ensemble. This property is used, however, only to fix the s- to p-wave level density ratio as proportional to (2J+1) with a spin cut-off correction. B - Method of solution: The method used is an extension of that described by Moore et al. in reference (1), and is based on the method of moments of a truncated Porter-Thomas distribution. C - Restrictions on the complexity of the problem: Parameters for a maximum of 500 individual resonances can be specified. This restriction can be relaxed by increasing array dimensions

  14. P-wave dispersion: relationship to left ventricular function in sickle cell anaemia.

    Science.gov (United States)

    Oguanobi, N I; Onwubere, B J; Ike, S O; Anisiuba, B C; Ejim, E C; Ibegbulam, O G

    2011-01-01

    The prognostic implications of P-wave dispersion in patients with a variety of cardiac disease conditions are increasingly being recognised. The relationship between P-wave dispersion and left ventricular function in sickle cell anaemia is unknown. This study was aimed at evaluating the relationship between P-wave dispersion and left ventricular function in adult Nigerian sickle cell anaemia patients. Between February and August 2007, a total of 62 sickle cell anaemia patients (aged 18-44 years; mean 28.27 ± 5.58) enrolled in the study. These were drawn from patients attending the adult sickle cell clinic of the University of Nigeria Teaching Hospital, Ituku-Ozalla, Enugu. An equal number of age- and gender-matched normal subjects served as controls. All the participants were evaluated with electrocardiography and echocardiography. P-wave dispersion was defined as the difference between the maximum and minimum P-wave duration measured in a 12-lead electrocardiogram. P-wave duration and P-wave dispersion were significantly higher in patients than in controls. Significant correlation was demonstrated between P-wave dispersion and age in the patients (r = 0.387; p = 0.031). A comparison of subsets of sickle cell anaemia patients and controls with comparable haematocrit values (30-35%) showed significantly higher P-wave duration and P-wave dispersion in the patients than in the controls. The P-wave duration in patients and controls, respectively, was 111.10 ± 14.53 ms and 89.14 ± 16.45 ms (t = 3.141; p = 0.006). P-wave dispersion was 64.44 ± 15.86 ms in the patients and 36.43 ± 10.35 ms in the controls (t = 2.752; p = 0.013). Significant negative correlation was found between P-wave dispersion and left ventricular transmitral E/A ratio (r = -0.289; p = 0.023). These findings suggest that P-wave dispersion could be useful in the evaluation of sickle cell patients with left ventricular diastolic dysfunction. Further prospective studies are recommended to evaluate

  15. Atrial Arrhythmias in Astronauts. Summary of a NASA Summit

    Science.gov (United States)

    Barr, Yael; Watkins, Sharmila; Polk, J. D.

    2011-01-01

    This slide presentation reviews the findings of a panel of heart experts brought together to study if atrial arrhythmias more prevalent in astronauts, and potential risk factors that may predispose astronauts to atrial arrhythmias. The objective of the panel was to solicit expert opinion on screening, diagnosis, and treatment options, identify gaps in knowledge, and propose relevant research initiatives. While Atrial Arrhythmias occur in approximately the same percents in astronauts as in the general population, they seem to occur at younger ages in astronauts. Several reasons for this predisposition were given: gender, hypertension, endurance training, and triggering events. Potential Space Flight-Related Risk factors that may play a role in precipitating lone atrial fibrillation were reviewed. There appears to be no evidence that any variable of the space flight environment increases the likelihood of developing atrial arrhythmias during space flight.

  16. What is the difference in the p-wave and s-wave photodetachment in an electric field?

    OpenAIRE

    Du, M. L.

    2009-01-01

    By applying closed-orbit theory to an existing model, a simple formula is derived for the modulation function of s-wave photo-detachment in the presence of a static electric field. We then compare the s-wave modulation function with the p-wave modulation function. We show the maximums (minimums) in the s-wave modulation function correspond to the minimums (maximums) in the p-wave modulation function because of a phase difference of $\\pi$ in their oscillations. The oscillation amplitude in the...

  17. Initiation and dynamics of a spiral wave around an ionic heterogeneity in a model for human cardiac tissue.

    Science.gov (United States)

    Defauw, Arne; Dawyndt, Peter; Panfilov, Alexander V

    2013-12-01

    In relation to cardiac arrhythmias, heterogeneity of cardiac tissue is one of the most important factors underlying the onset of spiral waves and determining their type. In this paper, we numerically model heterogeneity of realistic size and value and study formation and dynamics of spiral waves around such heterogeneity. We find that the only sustained pattern obtained is a single spiral wave anchored around the heterogeneity. Dynamics of an anchored spiral wave depend on the extent of heterogeneity, and for certain heterogeneity size, we find abrupt regional increase in the period of excitation occurring as a bifurcation. We study factors determining spatial distribution of excitation periods of anchored spiral waves and discuss consequences of such dynamics for cardiac arrhythmias and possibilities for experimental testings of our predictions.

  18. ESTIMA, Neutron Width Level Spacing, Neutron Strength Function of S- Wave, P-Wave Resonances

    International Nuclear Information System (INIS)

    Fort, E.

    1982-01-01

    1 - Description of problem or function: ESTIMA calculates level spacing and neutron strength function of a mixed sequence of s- and p-wave resonances given a set of neutron widths as input parameters. Three algorithms are used, two of which calculate s-wave average parameters and assume that the reduced widths obey a Porter-Thomas distribution truncated by a minimum detection threshold. The third performs a maximum likelihood fit to a truncated chi-squared distribution of any specified number of degrees of freedom, i.e. it can be used for calculating s-wave or p-wave average parameters. Resonances of undeclared angular orbital momentum are divided into groups of probable s-wave and probable p-wave by a simple application of Bayes' Theorem. 2 - Method of solution: Three algorithms are used: i) GAMN method, based on simple moments properties of a Porter-Thomas distribution. ii) Missing Level Estimator, a simplified version of the algorithm used by the program BAYESZ. iii) ESTIMA, a maximum likelihood fit. 3 - Restrictions on the complexity of the problem: A maximum of 400 resonances is allowed in the version available from NEADB, however this restriction can be relaxed by increasing array dimensions

  19. Magnetohydrodynamic waves driven by p-modes

    International Nuclear Information System (INIS)

    Khomenko, Elena; Santamaria, Irantzu Calvo

    2013-01-01

    Waves are observed at all layers of the solar atmosphere and the magnetic field plays a key role in their propagation. While deep down in the atmosphere the p-modes are almost entirely of acoustic nature, in the upper layers magnetic forces are dominating, leading to a large variety of new wave modes. Significant advances have been made recently in our understanding of the physics of waves interaction with magnetic structures, with the help of analytical theories, numerical simulations, as well as high-resolution observations. In this contribution, we review recent observational findings and current theoretical ideas in the field, with an emphasis on the following questions: (i) Peculiarities of the observed wave propagation in network, plage and facular regions; (ii) Role of the mode transformation and observational evidences of this process: (iii) Coupling of the photosphere, chromosphere, and above by means of waves propagating in magnetic structures.

  20. Ambulatory cardiac arrhythmias in relation to mild hypokalaemia and prognosis in community dwelling middle-aged and elderly subjects

    DEFF Research Database (Denmark)

    Mattsson, Nick; Sadjadieh, Golnaz; Kumarathurai, Preman

    2016-01-01

    with frequency of premature ventricular complexes (PVCs) especially in combination with diuretic treatment (r = -0.22, P = 0.015). Hypokalaemia was not associated with supraventricular arrhythmias. Subjects at lowest quintile of p-potassium (mean 3.42, range 2.7-3.6 mmol/L) were defined as hypokalaemic......, 10 and 15 per 1000 patient-year in those with one abnormality, and 3 per 1000 patient-year in subjects with no abnormality. One variable combining hypokalaemia with excessive supraventricular arrhythmias gave similar results in univariate analysis, but not after multivariate adjustments. CONCLUSION...

  1. Selective detection and recovery of gold at tannin-immobilized non-conducting electrode

    Energy Technology Data Exchange (ETDEWEB)

    Banu, Khaleda, E-mail: kbanu@ucla.edu [Department of Molecular and Medical Pharmacology, University of California, Los Angeles, CA 90095 (United States); Venture Business Laboratory, Center for Advanced Science and Innovation, Osaka University, Suita, Osaka 565-0871 (Japan); Shimura, Takayoshi [Venture Business Laboratory, Center for Advanced Science and Innovation, Osaka University, Suita, Osaka 565-0871 (Japan); Department of Material and Life Science, Division of Advanced Science and Biotechnology, Graduate School of Engineering, Osaka University (Japan); Sadeghi, Saman, E-mail: samsadeghi@mednet.ucla.edu [Department of Molecular and Medical Pharmacology, University of California, Los Angeles, CA 90095 (United States)

    2015-01-01

    Highlights: • Selective detection of gold at non-conducting (NC) polymer modified electrode. • Mimosa tannin oxidized on glassy carbon electrode surface as NC polymeric film. • Permselective diffusion and mediated electron transfer at NC electrode surface. • Chemical recovery of gold is due to the reducing ability of the NC polymeric film. • Adsorption capacity of Au(III) on carbon fiber was 29 ± 1.45 mg g{sup −1} at 60 °C. - Abstract: A tannin-immobilized glassy carbon electrode (TIGC) was prepared via electrochemical oxidation of the naturally occurring polyphenolic mimosa tannin, which generated a non-conducting polymeric film (NCPF) on the electrode surface. The fouling of the electrode surface by the electropolymerized film was evaluated by monitoring the electrode response of ferricyanide ions as a redox marker. The NCPF was permselective to HAuCl{sub 4}, and the electrochemical reduction of HAuCl{sub 4} to metallic gold at the TIGC electrode was evaluated by recording the reduction current during cyclic voltammetry measurement. In the mixed electrolyte containing HAuCl{sub 4} along with FeCl{sub 3} and/or CuCl{sub 2}, the NCPF remained selective toward the electrochemical reduction of HAuCl{sub 4} into the metallic state. The chemical reduction of HAuCl{sub 4} into metallic gold was also observed when the NCPF was inserted into an acidic gold solution overnight. The adsorption capacity of Au(III) on tannin-immobilized carbon fiber was 29 ± 1.45 mg g{sup −1} at 60 °C. In the presence of excess Cu(II) and Fe(III), tannin-immobilized NCPF proved to be an excellent candidate for the selective detection and recovery of gold through both electrochemical and chemical processes.

  2. Selective detection and recovery of gold at tannin-immobilized non-conducting electrode

    International Nuclear Information System (INIS)

    Banu, Khaleda; Shimura, Takayoshi; Sadeghi, Saman

    2015-01-01

    Highlights: • Selective detection of gold at non-conducting (NC) polymer modified electrode. • Mimosa tannin oxidized on glassy carbon electrode surface as NC polymeric film. • Permselective diffusion and mediated electron transfer at NC electrode surface. • Chemical recovery of gold is due to the reducing ability of the NC polymeric film. • Adsorption capacity of Au(III) on carbon fiber was 29 ± 1.45 mg g −1 at 60 °C. - Abstract: A tannin-immobilized glassy carbon electrode (TIGC) was prepared via electrochemical oxidation of the naturally occurring polyphenolic mimosa tannin, which generated a non-conducting polymeric film (NCPF) on the electrode surface. The fouling of the electrode surface by the electropolymerized film was evaluated by monitoring the electrode response of ferricyanide ions as a redox marker. The NCPF was permselective to HAuCl 4 , and the electrochemical reduction of HAuCl 4 to metallic gold at the TIGC electrode was evaluated by recording the reduction current during cyclic voltammetry measurement. In the mixed electrolyte containing HAuCl 4 along with FeCl 3 and/or CuCl 2 , the NCPF remained selective toward the electrochemical reduction of HAuCl 4 into the metallic state. The chemical reduction of HAuCl 4 into metallic gold was also observed when the NCPF was inserted into an acidic gold solution overnight. The adsorption capacity of Au(III) on tannin-immobilized carbon fiber was 29 ± 1.45 mg g −1 at 60 °C. In the presence of excess Cu(II) and Fe(III), tannin-immobilized NCPF proved to be an excellent candidate for the selective detection and recovery of gold through both electrochemical and chemical processes

  3. A deterministic model for the growth of non-conducting electrical tree structures

    International Nuclear Information System (INIS)

    Dodd, S J

    2003-01-01

    Electrical treeing is of interest to the electrical generation, transmission and distribution industries as it is one of the causes of insulation failure in electrical machines, switchgear and transformer bushings. In this paper a deterministic electrical tree growth model is described. The model is based on electrostatics and local electron avalanches to model partial discharge activity within the growing tree structure. Damage to the resin surrounding the tree structure is dependent on the local electrostatic energy dissipation by partial discharges within the tree structure and weighted by the magnitudes of the local electric fields in the resin surrounding the tree structure. The model is successful in simulating the formation of branched structures without the need of a random variable, a requirement of previous stochastic models. Instability in the spatial development of partial discharges within the tree structure takes the role of the stochastic element as used in previous models to produce branched tree structures. The simulated electrical trees conform to the experimentally observed behaviour; tree length versus time and electrical tree growth rate as a function of applied voltage for non-conducting electrical trees. The phase synchronous partial discharge activity and the spatial distribution of emitted light from the tree structure are also in agreement with experimental data for non-conducting trees as grown in a flexible epoxy resin and in polyethylene. The fact that similar tree growth behaviour is found using pure amorphous (epoxy resin) and semicrystalline (polyethylene) materials demonstrate that neither annealed or quenched noise, representing material inhomogeneity, is required for the formation of irregular branched structures (electrical trees). Instead, as shown in this paper, branched growth can occur due to the instability of individual discharges within the tree structure

  4. s- and p-wave neutron spectroscopy. Xc. Intermediate structure: 88Sr

    International Nuclear Information System (INIS)

    Malan, J.G.; Pineo, W.F.E.; Divadeenam, M.; Choi, B.H.; Bilpuch, E.G.; Newson, H.W.

    1975-01-01

    Neutron total cross section measurements of natural Sr were made from 50-875 keV using a high resolution proton beam and the 7 Li(p,n) reaction as a neutron source. These data were analyzed with the help of an R-Matrix code to extract resonance (energies and other) parameters up to about 850 keV. 2p-1h and particle-vibration doorway interpretation of the s-,p- and d-wave resonances is attempted in terms of the sum rule Σγ/subn/ 2 =γ/subd/ 2 . Predictions based on both of these models agree with the experimental results. As expected the p-wave resonances are stronger than either s- and d-wave structure. Theory accounts for the p-wave strength remarkably well. Possible location of the p-wave s.p. resonance is reproduced with a real potential and its damping due to the imaginary potential is calculated. More fragmentation of the strong p-wave doorways is observed than was expected for a compound nucleus so near 90 Zr, but a larger strength function is observed, apparently due to the p-wave giant resonance. (U.S.)

  5. Assembly of graphene oxide on nonconductive nonwovens by the synergistic effect of interception and electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Kunyan; Zhu, Ting; Li, Xianhua; Shan, Mingjing; Xu, Zhiwei, E-mail: xuzhiwei@tjpu.edu.cn; Jiao, Yanan [Tianjin Polytechnic University, Key Laboratory of Advanced Braided Composites, Ministry of Education (China)

    2015-09-15

    Electrophoretic deposition has always been an attractive method to deposit nanoparticles on conductive materials, while most fiber-based materials have poor conductivity which limits the application of electrophoretic deposition in assembling nanoparticles onto fiber-based materials. A new approach to assemble graphene oxide (GO) nanosheets on nonconductive nonwovens via the synergistic effect of electrophoresis and fiber interception was reported in this study. To improve surface wettability, polypropylene (PP) nonwovens were modified by acrylic acid and subsequent N{sub 2} plasma treatment. Then GO nanosheets were anchored onto modified nonwovens by electrophoresis process and nonwoven interception. The results of scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) manifested that etching and grafting simultaneously occurred on the surface of modified PP nonwovens, resulting in a great improvement of nonwoven hydrophily, which corresponded to the results of water contact angle. Furthermore, the results of X-ray diffraction, energy dispersive X-ray, SEM, and FTIR indicated that different amounts of GO nanosheets were successfully assembled onto modified PP nonwovens. This method provides a new avenue for incorporating carbon nanoparticles with nonconductive fiber-based materials, and modified PP nonwovens assembled with GO nanosheets show good air filtration performance for sodium chloride aerosol with a filtration efficiency of 87.9 % and a pressure drop of 36.4 mmH{sub 2}O, and the reduced GO/PP composite nonwovens exhibit enhanced conductivity.

  6. Novel Calmodulin (CALM2) Mutations Associated with Congenital Arrhythmia Susceptibility

    Science.gov (United States)

    Makita, Naomasa; Yagihara, Nobue; Crotti, Lia; Johnson, Christopher N.; Beckmann, Britt-Maria; Roh, Michelle S.; Shigemizu, Daichi; Lichtner, Peter; Ishikawa, Taisuke; Aiba, Takeshi; Homfray, Tessa; Behr, Elijah R.; Klug, Didier; Denjoy, Isabelle; Mastantuono, Elisa; Theisen, Daniel; Tsunoda, Tatsuhiko; Satake, Wataru; Toda, Tatsushi; Nakagawa, Hidewaki; Tsuji, Yukiomi; Tsuchiya, Takeshi; Yamamoto, Hirokazu; Miyamoto, Yoshihiro; Endo, Naoto; Kimura, Akinori; Ozaki, Kouichi; Motomura, Hideki; Suda, Kenji; Tanaka, Toshihiro; Schwartz, Peter J.; Meitinger, Thomas; Kääb, Stefan; Guicheney, Pascale; Shimizu, Wataru; Bhuiyan, Zahurul A.; Watanabe, Hiroshi; Chazin, Walter J.; George, Alfred L.

    2014-01-01

    Background Genetic predisposition to life-threatening cardiac arrhythmias such as in congenital long-QT syndrome (LQTS) and catecholaminergic polymorphic ventricular tachycardia (CPVT) represent treatable causes of sudden cardiac death in young adults and children. Recently, mutations in calmodulin (CALM1, CALM2) have been associated with severe forms of LQTS and CPVT, with life-threatening arrhythmias occurring very early in life. Additional mutation-positive cases are needed to discern genotype-phenotype correlations associated with calmodulin mutations. Methods and Results We employed conventional and next-generation sequencing approaches including exome analysis in genotype-negative LQTS probands. We identified five novel de novo missense mutations in CALM2 in three subjects with LQTS (p.N98S, p.N98I, p.D134H) and two subjects with clinical features of both LQTS and CPVT (p.D132E, p.Q136P). Age of onset of major symptoms (syncope or cardiac arrest) ranged from 1–9 years. Three of five probands had cardiac arrest and one of these subjects did not survive. Although all probands had LQTS, two subjects also exhibited electrocardiographic features consistent with CPVT. The clinical severity among subjects in this series was generally less than that originally reported for CALM1 and CALM2 associated with recurrent cardiac arrest during infancy. Four of five probands responded to β-blocker therapy whereas one subject with mutation p.Q136P died suddenly during exertion despite this treatment. Mutations affect conserved residues located within calcium binding loops III (p.N98S, p.N98I) or IV (p.D132E, p.D134H, p.Q136P) and caused reduced calcium binding affinity. Conclusions CALM2 mutations can be associated with LQTS and with overlapping features of LQTS and CPVT. PMID:24917665

  7. Channelopathies - emerging trends in the management of inherited arrhythmias

    NARCIS (Netherlands)

    Chockalingam, Priya; Mizusawa, Yuka; Wilde, Arthur A. M.

    2015-01-01

    In spite of their relative rarity, inheritable arrhythmias have come to the forefront as a group of potentially fatal but preventable cause of sudden cardiac death in children and (young) adults. Comprehensive management of inherited arrhythmias includes diagnosing and treating the proband and

  8. Temporal change in shallow subsurface P- and S-wave velocities and S-wave anisotropy inferred from coda wave interferometry

    Science.gov (United States)

    Yamamoto, M.; Nishida, K.; Takeda, T.

    2012-12-01

    Recent progresses in theoretical and observational researches on seismic interferometry reveal the possibility to detect subtle change in subsurface seismic structure. This high sensitivity of seismic interferometry to the medium properties may thus one of the most important ways to directly observe the time-lapse behavior of shallow crustal structure. Here, using the coda wave interferometry, we show the co-seismic and post-seismic changes in P- and S-wave velocities and S-wave anisotropy associated with the 2011 off the Pacific coast of Tohoku earthquake (M9.0). In this study, we use the acceleration data recorded at KiK-net stations operated by NIED, Japan. Each KiK-net station has a borehole whose typical depth is about 100m, and two three-component accelerometers are installed at the top and bottom of the borehole. To estimate the shallow subsurface P- and S-wave velocities and S-wave anisotropy between two sensors and their temporal change, we select about 1000 earthquakes that occurred between 2004 and 2012, and extract body waves propagating between borehole sensors by computing the cross-correlation functions (CCFs) of 3 x 3 component pairs. We use frequency bands of 2-4, 4-8, 8-16 Hz in our analysis. Each averaged CCF shows clear wave packets traveling between borehole sensors, and their travel times are almost consistent with those of P- and S-waves calculated from the borehole log data. Until the occurrence of the 2011 Tohoku earthquake, the estimated travel time at each station is rather stable with time except for weak seasonal/annual variation. On the other hand, the 2011 Tohoku earthquake and its aftershocks cause sudden decrease in the S-wave velocity at most of the KiK-net stations in eastern Japan. The typical value of S-wave velocity changes, which are measured by the time-stretching method, is about 5-15%. After this co-seismic change, the S-wave velocity gradually recovers with time, and the recovery continues for over one year following the

  9. Prevalence of Fibromyalgia Syndrome and Its Correlations with Arrhythmia in Patients with Palpitations

    Directory of Open Access Journals (Sweden)

    Ayhan Aşkın

    2018-04-01

    Full Text Available Objective: It is aimed to determine the prevalence of fibromyalgia syndrome (FMS and its correlations with arrhythmia in patients with palpitations. Material and Methods: Sixty-two patients who underwent electrophysiological study (EPS due to palpitation complaints in Cardiology department and 40 healthy controls were included in the study. The precise diagnosis of arrhythmia was established using EPS. All participants were screened for FMS using American College of Rheumatology 2010 Fibromyalgia diagnostic criteria. Clinical assessments included measurement of severity of pain, fatigue and morning fatigue with visual analog scale (VAS, functional status with Fibromyalgia Impact Questionnaire (FIQ, and anxiety/depression with Hospital Anxiety and Depression Scale (HAD. Results: FMS was diagnosed in 22 of the 62 patients (36%, and 4 of the 40 healthy controls (10% (p 0.05. EPS+ patients with FMS had higher fatigue levels, HAD and FIQ scores than EPS− patients, although statistically insignificant. HV durations were statistically longer in the EPS− subgroup (p < 0.05 but other EPS data were similar. Conclusion: FMS frequency and HAD anxiety scores were found to be higher in patients with palpitation complaints. However, we found no association between arrhythmia, EPS parameters and FMS. In our clinical practice we should keep in mind to carry out assessments in terms of FMS in patients with palpitation.

  10. Discrete potentials guided radiofrequency ablation for idiopathic outflow tract ventricular arrhythmias.

    Science.gov (United States)

    Liu, Enzhao; Xu, Gang; Liu, Tong; Ye, Lan; Zhang, Qitong; Zhao, Yanshu; Li, Guangping

    2015-03-01

    Discrete potentials (DPs) have been recorded and targeted as the site of ablation of the outflow tract arrhythmias. The aim of the present study was to investigate the significance of DPs with respect to mapping and ablation for idiopathic outflow tract premature ventricular contractions (PVCs) or ventricular tachycardias (VTs). Seventeen consecutive patients with idiopathic right or left ventricular outflow tract PVCs/VTs who underwent radiofrequency catheter ablation were included. Intracardiac electrograms during the mapping and ablation were analysed. During sinus rhythm, sharp high-frequency DPs that displayed double or multiple components were recorded following or buried in the local ventricular electrograms in all of the 17 patients, peak amplitude 0.51 ± 0.21 mV. The same potential was recorded prior to the local ventricular potential of the PVCs/VTs. Spontaneous reversal of the relationship of the DPs to the local ventricular electrogram during the arrhythmias was noted. The DPs were related to a region of low voltage showed by intracardiac high-density contact mapping. At the sites with DPs, lower unipolar and bipolar ventricular voltage of sinus beats were noted compared with the adjacent regions without DPs (unipolar: 6.1 ± 1.8 vs. 8.3 ± 2.3 mV, P Discrete potentials were not present in seven controls. Discrete potentials and related low-voltage regions were common in idiopathic outflow tract ventricular arrhythmias. Discrete potential- and substrate-guided ablation strategy will help to reduce the recurrence of idiopathic outflow tract arrhythmias. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  11. P-wave duration and the risk of atrial fibrillation

    DEFF Research Database (Denmark)

    Nielsen, Jonas B; Kühl, Jørgen T; Pietersen, Adrian

    2015-01-01

    BACKGROUND: Results on the association between P-wave duration and the risk of atrial fibrillation (AF) are conflicting. OBJECTIVE: The purpose of this study was to obtain a detailed description of the relationship between P-wave duration and the risk of AF. METHODS: Using computerized analysis o...

  12. Understand Your Risk for Arrhythmia

    Science.gov (United States)

    ... is likely monitoring your heart rhythm with regular EKGs ( electrocardiograms ). But arrhythmias that occur infrequently may not ... patient sheets Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  13. Dispersion of repolarization and refractoriness are determinants of arrhythmia phenotype in transgenic mice with long QT.

    Science.gov (United States)

    London, Barry; Baker, Linda C; Petkova-Kirova, Polina; Nerbonne, Jeanne M; Choi, Bum-Rak; Salama, Guy

    2007-01-01

    Enhanced dispersion of repolarization (DR) and refractoriness may be a unifying mechanism central to arrhythmia genesis in the long QT (LQT) syndrome. The role of DR in promoting arrhythmias was investigated in several strains of molecularly engineered mice: (a) Kv4.2 dominant negative transgenic (Kv4.2DN) that lacks the fast component of the transient outward current, I(to,f), have action potential (AP) and QT prolongation, but no spontaneous arrhythmias, (b) Kv1.4 targeted mice (Kv1.4-/-) that lack the slow component of I(to) (I(to,s)), have no QT prolongation and no spontaneous arrhythmias, and (c) double transgenic (Kv4.2DN x Kv1.4-/-) mice that lack both I(to,f) and I(to,s), have AP and QT prolongation, and spontaneous ventricular tachyarrhythmias. Hearts were perfused, stained with di-4-ANEPPS and optically mapped. Activation patterns and conduction velocities were similar between the strains but AP duration at 75% recovery (APD75) was longer in Kv4.2DN (28.0 +/- 2.5 ms, P mice than controls (20.3 +/- 1.0 ms, n = 5). Dispersion of refractoriness between apex and base was markedly reduced in Kv4.2DN (0.3 +/- 0.5 ms, n = 6, P mice compared with controls (10 +/- 2 ms, n = 5). A premature pulse elicited ventricular tachycardia (VT) in Kv1.4-/- (n = 4/5) and Kv4.2DN x Kv1.4-/- hearts (n = 5/5) but not Kv4.2DN hearts (n = 0/6). Voltage-clamp recordings showed that I(to,f) was 30% greater in myocytes from the apex than base which may account for the absence of DR in Kv4.2DN mice. Thus, dispersion of repolarization (DR) appears to be an important determinant of arrhythmia vulnerability.

  14. Observational cohort study of ventricular arrhythmia in adults with Marfan syndrome caused by FBN1 mutations.

    Directory of Open Access Journals (Sweden)

    Ali Aydin

    Full Text Available Marfan syndrome is associated with ventricular arrhythmia but risk factors including FBN1 mutation characteristics require elucidation.We performed an observational cohort study of 80 consecutive adults (30 men, 50 women aged 42±15 years with Marfan syndrome caused by FBN1 mutations. We assessed ventricular arrhythmia on baseline ambulatory electrocardiography as >10 premature ventricular complexes per hour (>10 PVC/h, as ventricular couplets (Couplet, or as non-sustained ventricular tachycardia (nsVT, and during 31±18 months of follow-up as ventricular tachycardia (VT events (VTE such as sudden cardiac death (SCD, and sustained ventricular tachycardia (sVT. We identified >10 PVC/h in 28 (35%, Couplet/nsVT in 32 (40%, and VTE in 6 patients (8%, including 3 with SCD (4%. PVC>10/h, Couplet/nsVT, and VTE exhibited increased N-terminal pro-brain natriuretic peptide serum levels(P10/h and Couplet/nsVT also related to increased indexed end-systolic LV diameters (P = .024 and P = .020, to moderate mitral valve regurgitation (P = .018 and P = .003, and to prolonged QTc intervals (P = .001 and P = .006, respectively. Moreover, VTE related to mutations in exons 24-32 (P = .021. Kaplan-Meier analysis corroborated an association of VTE with increased NT-proBNP (P<.001 and with mutations in exons 24-32 (P<.001.Marfan syndrome with causative FBN1 mutations is associated with an increased risk for arrhythmia, and affected persons may require life-long monitoring. Ventricular arrhythmia on electrocardiography, signs of myocardial dysfunction and mutations in exons 24-32 may be risk factors of VTE.

  15. [Analysis of the heart sound with arrhythmia based on nonlinear chaos theory].

    Science.gov (United States)

    Ding, Xiaorong; Guo, Xingming; Zhong, Lisha; Xiao, Shouzhong

    2012-10-01

    In this paper, a new method based on the nonlinear chaos theory was proposed to study the arrhythmia with the combination of the correlation dimension and largest Lyapunov exponent, through computing and analyzing these two parameters of 30 cases normal heart sound and 30 cases with arrhythmia. The results showed that the two parameters of the heart sounds with arrhythmia were higher than those with the normal, and there was significant difference between these two kinds of heart sounds. That is probably due to the irregularity of the arrhythmia which causes the decrease of predictability, and it's more complex than the normal heart sound. Therefore, the correlation dimension and the largest Lyapunov exponent can be used to analyze the arrhythmia and for its feature extraction.

  16. Seasonality of P wave microseisms from NCF-based beamforming using ChinArray

    Science.gov (United States)

    Wang, Weitao; Gerstoft, Peter; Wang, Baoshan

    2018-06-01

    Teleseismic P wave microseisms produce interference signals with high apparent velocity in noise cross-correlation functions (NCFs). Sources of P wave microseisms can be located with NCFs from seismic arrays. Using the vertical-vertical component NCFs from a large-aperture array in southwestern China (ChinArray), we studied the P wave source locations and their seasonality of microseisms at two period bands (8-12 and 4-8 s) with an NCF-based beamforming method. The sources of P, PP and PKPbc waves are located. The ambiguity between P and PP source locations is analysed using averaged significant ocean wave height and sea surface pressure as constraints. The results indicate that the persistent P wave sources are mainly located in the deep oceans such as the North Atlantic, North Pacific and Southern Ocean, in agreement with previous studies. The Gulf of Alaska is found to generate P waves favouring the 8-12 s period band. The seasonality of P wave sources is consistent with the hemispheric storm pattern, which is stronger in local winter. Using the identified sources, arrival times of the interference signals are predicted and agree well with observations. The interference signals exhibit seasonal variation, indicating that body wave microseisms in southwestern China are from multiple seasonal sources.

  17. Atrial arrhythmia in ageing spontaneously hypertensive rats: unraveling the substrate in hypertension and ageing.

    Directory of Open Access Journals (Sweden)

    Dennis H Lau

    Full Text Available BACKGROUND: Both ageing and hypertension are known risk factors for atrial fibrillation (AF although the pathophysiological contribution or interaction of the individual factors remains poorly understood. Here we aim to delineate the arrhythmogenic atrial substrate in mature spontaneously hypertensive rats (SHR. METHODS: SHR were studied at 12 and 15 months of age (n = 8 per group together with equal numbers of age-matched normotensive Wistar-Kyoto control rats (WKY. Electrophysiologic study was performed on superfused isolated right and left atrial preparations using a custom built high-density multiple-electrode array to determine effective refractory periods (ERP, atrial conduction and atrial arrhythmia inducibility. Tissue specimens were harvested for structural analysis. RESULTS: COMPARED TO WKY CONTROLS, THE SHR DEMONSTRATED: Higher systolic blood pressure (p<0.0001, bi-atrial enlargement (p<0.05, bi-ventricular hypertrophy (p<0.05, lower atrial ERP (p = 0.008, increased atrial conduction heterogeneity (p = 0.001 and increased atrial interstitial fibrosis (p = 0.006 & CD68-positive macrophages infiltration (p<0.0001. These changes resulted in higher atrial arrhythmia inducibility (p = 0.01 and longer induced AF episodes (p = 0.02 in 15-month old SHR. Ageing contributed to incremental bi-atrial hypertrophy (p<0.01 and atrial conduction heterogeneity (p<0.01 without affecting atrial ERP, fibrosis and arrhythmia inducibility. The limited effect of ageing on the atrial substrate may be secondary to the reduction in CD68-positive macrophages. CONCLUSIONS: Significant atrial electrical and structural remodeling is evident in the ageing spontaneously hypertensive rat atria. Concomitant hypertension appears to play a greater pathophysiological role than ageing despite their compounding effect on the atrial substrate. Inflammation is pathophysiologically linked to the pro-fibrotic changes in the hypertensive atria.

  18. Depth of source from long period P-waves

    International Nuclear Information System (INIS)

    Roy, Falguni

    1986-01-01

    Short period (SP) seismograms are much better than long period (LP) seismograms to get the time resolution needed for the focal depth estimation. However, complex scattering effects due to crustal inhomogeneities and also the multi-pathing of signals usually complicate the short period records. On the other hand the seismograms from long period signals demonstrate clear coherent body waves. Therefore, for intermediate depths (15-60 km) prediction error filtering of LP signals will be useful for identifying the depth phases. Such a study has been carried out in the first part of this report. In a group of 7 events, the p p phases have been extracted from LP signals and the depths so estimated compared well with the published data. For explosions at shallow depths (depth p phases will tend to cancel each other in LP seismograms. As the source depth increases, the cancellation becomes less effective. This feature can be used for the identification of an event as well as for getting an estimate of the source depth. This phenomenon can be successfully exploited for identifying multiple explosions, because at teleseismic distances (Δ > 30 o ) no LP (around 20s period) P waves will be seen in the seismogram due to such events whereas relatively strong SP signals and LP Rayleigh waves will be observed. This phenomenon has been studied for 16 events. For three of these events having m b as high as 6.1 and presumed to be underground explosions, one could not see any P wave on remaining 13 events (which were classified as earthquakes), it was possible to set a threshold value of m b above which an earthquake should produce LP P-wave signals at a given distance. (author)

  19. What Do s- and p-Wave Neutron Average Radiative Widths Reveal

    Energy Technology Data Exchange (ETDEWEB)

    Mughabghab, S.F.

    2010-04-30

    A first observation of two resonance-like structures at mass numbers 92 and 112 in the average capture widths of the p-wave neutron resonances relative to the s-wave component is interpreted in terms of a spin-orbit splitting of the 3p single-particle state into P{sub 3/2} and P{sub 1/2} components at the neutron separation energy. A third structure at about A = 124, which is not correlated with the 3p-wave neutron strength function, is possibly due to the Pygmy Dipole Resonance. Five significant results emerge from this investigation: (i) The strength of the spin-orbit potential of the optical-model is determined as 5.7 {+-} 0.5 MeV, (ii) Non-statistical effects dominate the p-wave neutron-capture in the mass region A = 85 - 130, (iii) The background magnitude of the p-wave average capture-width relative to that of the s-wave is determined as 0.50 {+-} 0.05, which is accounted for quantitatively in tenns of the generalized Fermi liquid model of Mughabghab and Dunford, (iv) The p-wave resonances arc partially decoupled from the giant-dipole resonance (GDR), and (v) Gamma-ray transitions, enhanced over the predictions of the GDR, are observed in the {sup 90}Zr - {sup 98}Mo and Sn-Ba regions.

  20. Dobutamine use for arrhythmia induction during electrical programmed heart stimulation

    International Nuclear Information System (INIS)

    Vanegas, Diego I; Perez, Climaco de J; Montenegro, Juan de J; Orjuela, Alejandro

    2006-01-01

    isoproterenol is the traditionally used drug for incrementing arrhythmia induction when this induction is not achieved during electric programmed heart stimulation under basal conditions. Dobutamine is an adrenergic agent, chemical precursor of isoproterenol, which can be an alternative for inducing arrhythmia during electrical programmed heart stimulation (PES). Patients and methods: a retrospective comparative study of the experience with dobutamine for inducing arrhythmia during electrical programmed heart stimulation was performed. The following data were collected: number of studies, data about the patient (medical record, age, gender, and study indication) protocol of programmed electrical stimulation, basal and under dobutamine or isoproterenol, and result of the study. Isoproterenol was used in doses of 1 to 3 micrograms per minute until the basal heart rate was incremented at least in 25%. Dobutamine was used in doses of 10 to 40 micrograms per kg of body weight, until obtaining the same increment in the basal heart rate. Results: 1054 electrophysiological studies were evaluated. In 144 patients (group A) isoproterenol was used and in 140, dobutamine (group B). In A group the mean age was 39.2 ± 16.2 and 58.3% were females. In-group B, mean age was 41.9 ± 18.6 and 51% were females. The most frequent symptom was palpitation and the most commonly induced arrhythmia was AV nodal reentry tachycardia in both groups. The induction of arrhythmia during the electrical programmed heat stimulation under drugs was similar in-group A (isoproterenol) respect to group B (dobutamine). Conclusions: There were no statistical significant differences in the induction of arrhythmia during electrical programmed heart stimulation using dobutamine or isoproterenol. Dobutamine may be safe and may be successfully used as an alternative to isoproterenol for arrhythmia induction during electrical programmed stimulation

  1. Effects of short-term administration of estradiol on reperfusion arrhythmias in rats of different ages

    International Nuclear Information System (INIS)

    Savergnini, S.Q.; Reis, A.M.; Santos, R.A.S.; Santos, P.E.B.; Ferreira, A.J.; Almeida, A.P.

    2012-01-01

    Little is known about age-related differences in short-term effects of estradiol on ischemia-reperfusion (I/R) insults. The present study was designed to evaluate the effects of short-term treatment with estradiol on reperfusion arrhythmias in isolated hearts of 6-7-week-old and 12-14-month-old female rats. Wistar rats were sham-operated, ovariectomized and treated with vehicle or ovariectomized and treated with 17β-estradiol (E 2 ; 5 µg·100 g −1 ·day −1 ) for 4 days. Hearts were perfused by the Langendorff technique. Reperfusion arrhythmias, i.e., ventricular tachycardia and/or ventricular fibrillation, were induced by 15 min of left coronary artery ligation and 30 min of reperfusion. The duration and incidence of I/R arrhythmias were significantly higher in young rats compared to middle-aged rats (arrhythmia severity index: 9.4 ± 1.0 vs 3.0 ± 0.3 arbitrary units, respectively, P < 0.05). In addition, middle-aged rats showed lower heart rate, systolic tension and coronary flow. Four-day E 2 treatment caused an increase in uterine weight. Although E 2 administration had no significant effect on the duration of I/R arrhythmias in middle-aged rats, it induced a marked reduction in the rhythm disturbances of young rats accompanied by a decrease in heart rate of isolated hearts. Also, this reduction was associated with an increase in QT interval. No significant changes were observed in the QT interval of middle-aged E 2 -treated rats. These data demonstrate that short-term estradiol treatment protects against I/R arrhythmias in hearts of young female rats. The anti-arrhythmogenic effect of estradiol might be related to a lengthening of the QT interval

  2. Effects of short-term administration of estradiol on reperfusion arrhythmias in rats of different ages

    Energy Technology Data Exchange (ETDEWEB)

    Savergnini, S.Q.; Reis, A.M. [Departamento de Fisiologia e Biofísica, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Santos, R.A.S. [1Departamento de Fisiologia e Biofísica, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Santos, P.E.B. [Departamento de Farmacologia, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Ferreira, A.J. [Departamento de Morfologia, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Almeida, A.P. [Departamento de Fisiologia e Biofísica, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2012-11-01

    Little is known about age-related differences in short-term effects of estradiol on ischemia-reperfusion (I/R) insults. The present study was designed to evaluate the effects of short-term treatment with estradiol on reperfusion arrhythmias in isolated hearts of 6-7-week-old and 12-14-month-old female rats. Wistar rats were sham-operated, ovariectomized and treated with vehicle or ovariectomized and treated with 17β-estradiol (E{sub 2}; 5 µg·100 g{sup −1}·day{sup −1}) for 4 days. Hearts were perfused by the Langendorff technique. Reperfusion arrhythmias, i.e., ventricular tachycardia and/or ventricular fibrillation, were induced by 15 min of left coronary artery ligation and 30 min of reperfusion. The duration and incidence of I/R arrhythmias were significantly higher in young rats compared to middle-aged rats (arrhythmia severity index: 9.4 ± 1.0 vs 3.0 ± 0.3 arbitrary units, respectively, P < 0.05). In addition, middle-aged rats showed lower heart rate, systolic tension and coronary flow. Four-day E{sub 2} treatment caused an increase in uterine weight. Although E{sub 2} administration had no significant effect on the duration of I/R arrhythmias in middle-aged rats, it induced a marked reduction in the rhythm disturbances of young rats accompanied by a decrease in heart rate of isolated hearts. Also, this reduction was associated with an increase in QT interval. No significant changes were observed in the QT interval of middle-aged E{sub 2}-treated rats. These data demonstrate that short-term estradiol treatment protects against I/R arrhythmias in hearts of young female rats. The anti-arrhythmogenic effect of estradiol might be related to a lengthening of the QT interval.

  3. Types of Arrhythmia in Children

    Science.gov (United States)

    ... even though they may need to keep taking medicine. Your child will probably need periodic check-ups but will ... minute. Understand and manage medications Parents of a child taking medicine for an arrhythmia should give the medicine at ...

  4. The occurrence of new arrhythmias after catheter-ablation of accessory pathway: Delayed arrhythmic side-effect of curative radiofrequency lesion?

    Directory of Open Access Journals (Sweden)

    Mujović Nebojša

    2011-01-01

    Full Text Available Introduction. New arrhythmias (NA may appear late after accessory pathway (AP ablation, but their relation to curative radiofrequency (RF lesion is unknown. Objective. The aim of this study was to determine the prevalence and predictors for NA occurrence after AP ablation and to investigate pro-arrhythmic effect of RF. Methods. Total of 124 patients (88 males, mean age 43±14 years with Wolff-Parkinson-White syndrome and single AP have been followed after successful RF ablation. Post-ablation finding of arrhythmia, not recorded before the procedure, was considered a NA. The origin of NA was assessed by analysis of P-wave and/or QRS-complex morphology, and, thereafter, it was compared with locations of previously ablated APs. Results. Over the follow-up of 4.3±3.9 years, NA was registered in 20 patients (16%. The prevalence of specific NAs was as follows: atrioventricular (AV block 0.8%, atrial premature beats 1.6%, atrial fibrillation 5.4%, atrial flutter 0.8%, sinus tachycardia 4.8%, ventricular premature beats (VPBs 7.3%. Multivariate Cox-regression analysis identified (1 pre-ablation history of pathway-mediated tachyarrhythmias >10 years (HR=3.54, p=0.016 and (2 septal AP location (HR=4.25, p=0.003, as the independent predictors for NA occurrence. In four NA cases (two cases of septal VPBs, one of typical AFL and one of AV-block presumed NA origin was identified in the vicinity of previous ablation target. Conclusion. NAs were found in 16% of patients after AP elimination. In few of these cases, late on-site arrhythmic effect of initially curative RF lesion might be possible. While earlier intervention could prevent NA occurrence, closer follow-up is advised after ablation of septal AP.

  5. Pharmacogenetics of drug-induced arrhythmias

    DEFF Research Database (Denmark)

    De Bruin, Marie L; van Puijenbroek, Eugene P; Bracke, Madelon

    2006-01-01

    PURPOSE: The bottleneck in pharmacogenetic research on rare adverse drug reactions (ADR) is retrieval of patients. Spontaneous reports of ADRs may form a useful source of patients. We investigated the feasibility of a pharmacogenetic study, in which cases were selected from the database...... of a spontaneous reporting system for ADRs, using drug-induced arrhythmias as an example. METHODS: Reports of drug-induced arrhythmias to proarrhythmic drugs were selected from the database of the Netherlands Pharmacovigilance Centre (1996-2003). Information on the patient's general practitioner (GP) was obtained...... be included in the study, giving an overall participation rate of 9% (4/45). The main reason for GPs not being willing to participate was lack of time. Variants were identified in KCNH2, SCN5A and KCNE1. CONCLUSIONS: Spontaneous reporting systems for ADRs may be used for pharmacogenetic research. The methods...

  6. EMHD micro-pumping of a non-conducting shear-thinning fluid under EDL phenomena

    International Nuclear Information System (INIS)

    Gaikwad, Harshad; Borole, Chetan; Basu, Dipankar N.; Mondal, Pranab K.

    2016-01-01

    The Electro-Magneto-Hydrodynamic (EMHD) pumping of a binary fluid system constituted by one non-conducting shear-thinning fluid (top layer) by exploiting the transverse momentum exchange through the interfacial viscous shearing effect from a conducting Newtonian fluid layer (bottom layer) in a microfluidic channel is investigated. An externally applied electric field drives the conducting fluid layer under the influence of an applied magnetic field as well. The study reveals that the volume transport of shear-thinning fluid gets augmented for low magnetic field strength, higher electrical double layer (EDL) effect, low viscosity ratio and moderate potential ratio. It is also established that the volumetric flow rate reduces significantly for the higher magnetic field strength. (author)

  7. The effect of Cardiac Arrhythmias Simulation Software on the nurses' learning and professional development.

    Science.gov (United States)

    Bazrafkan, Leila; Hemmati, Mehdi

    2018-04-01

    One of the important tasks of nurses in intensive care unit is interpretation of ECG. The use of training simulator is a new paradigm in the age of computers. This study was performed to evaluate the impact of cardiac arrhythmias simulator software on nurses' learning in the subspecialty Vali-Asr Hospital in 2016. This study was conducted by quasi-experimental randomized Salomon four group design with the participation of 120 nurses in subspecialty Vali-Asr Hospital in Tehran, Iran in 2016 that were selected purposefully and allocated in 4 groups. By this design other confounding factors such as the prior information, maturation and the role of sex and age were controlled by Solomon 4 design. The valid and reliable multiple choice test tools were used to gather information; the validity of the test was approved by experts and its reliability was obtained by Cronbach's alpha coefficient 0.89. At first, the knowledge and skills of the participants were assessed by a pre-test; following the educational intervention with cardiac arrhythmias simulator software during 14 days in ICUs, the mentioned factors were measured for the two groups again by a post-test in the four groups. Data were analyzed using the two way ANOVA. The significance level was considered as ptest results, using cardiac arrhythmias simulator software as an intervention was effective in the nurses' learning since a significant difference was found between pre-test and post-test in the first group (ptest showed that there was no interaction between pre-test and intervention in all of the three knowledge areas of cardiac arrhythmias, their treatments and their diagnosis (P>0.05). The use of software-based simulator for cardiac arrhythmias was effective in nurses' learning in light of its attractive components and interactive method. This intervention increased the knowledge of the nurses in cognitive domain of cardiac arrhythmias in addition to their diagnosis and treatment. Also, the package can be

  8. P-wave assignment of 232Th neutron resonances

    International Nuclear Information System (INIS)

    Corvi, F.; Pasquariello, G.; Veen, T. van der

    1978-01-01

    A method of p-wave assignment which exploits the parity dependence of the primary capture γ-ray spectrum was applied to the 232 Th resonance. The yield of capture γ-rays above 4.4 MeV from a 6 mm thick metallic thorium disk was measured in the neutron energy range 20-2200 eV and compared to a similar run with γ-rays in the range 3.7 - 4.4 MeV. A total of 58 resonances showing an enhancement of the high energy γ-ray yield were assigned as p-waves. Assuming that their reduced neutron widths follow a Porter-Thomas distribution, their average value and then the p-wave strength function S 1 were estimated with a maximum likelihood method. The results are: average neutron width=3.4(+0.8 or -0.6)meV; S 1 = 2.0 (+0.5 or -0.4).10 -4

  9. Holographic s-wave and p-wave Josephson junction with backreaction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yong-Qiang; Liu, Shuai [Institute of Theoretical Physics, Lanzhou University,Lanzhou 730000, People’s Republic of (China)

    2016-11-22

    In this paper, we study the holographic models of s-wave and p-wave Josephoson junction away from probe limit in (3+1)-dimensional spacetime, respectively. With the backreaction of the matter, we obtained the anisotropic black hole solution with the condensation of matter fields. We observe that the critical temperature of Josephoson junction decreases with increasing backreaction. In addition to this, the tunneling current and condenstion of Josephoson junction become smaller as backreaction grows larger, but the relationship between current and phase difference still holds for sine function. Moreover, condenstion of Josephoson junction deceases with increasing width of junction exponentially.

  10. Non-conductive nanomaterial enhanced electrochemical response in stripping voltammetry: The use of nanostructured magnesium silicate hollow spheres for heavy metal ions detection.

    Science.gov (United States)

    Xu, Ren-Xia; Yu, Xin-Yao; Gao, Chao; Jiang, Yu-Jing; Han, Dong-Dong; Liu, Jin-Huai; Huang, Xing-Jiu

    2013-08-06

    Nanostructured magnesium silicate hollow spheres, one kind of non-conductive nanomaterials, were used in heavy metal ions (HMIs) detection with enhanced performance for the first time. The detailed study of the enhancing electrochemical response in stripping voltammetry for simultaneous detection of ultratrace Cd(2+), Pb(2+), Cu(2+) and Hg(2+) was described. Electrochemical properties of modified electrodes were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The operational parameters which have influence on the deposition and stripping of metal ions, such as supporting electrolytes, pH value, and deposition time were carefully studied. The anodic stripping voltammetric performance toward HMIs was evaluated using square wave anodic stripping voltammetry (SWASV) analysis. The detection limits achieved (0.186nM, 0.247nM, 0.169nM and 0.375nM for Cd(2+), Pb(2+), Cu(2+) and Hg(2+)) are much lower than the guideline values in drinking water given by the World Health Organization (WHO). In addition, the interference and stability of the modified electrode were also investigated under the optimized conditions. An interesting phenomenon of mutual interference between different metal ions was observed. Most importantly, the sensitivity of Pb(2+) increased in the presence of certain concentrations of other metal ions, such as Cd(2+), Cu(2+) and Hg(2+) both individually and simultaneously. The proposed electrochemical sensing method is thus expected to open new opportunities to broaden the use of SWASV in analysis for detecting HMIs in the environment. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Effect of P T symmetry on nonlinear waves for three-wave interaction models in the quadratic nonlinear media

    Science.gov (United States)

    Shen, Yujia; Wen, Zichao; Yan, Zhenya; Hang, Chao

    2018-04-01

    We study the three-wave interaction that couples an electromagnetic pump wave to two frequency down-converted daughter waves in a quadratic optical crystal and P T -symmetric potentials. P T symmetric potentials are shown to modulate stably nonlinear modes in two kinds of three-wave interaction models. The first one is a spatially extended three-wave interaction system with odd gain-and-loss distribution in the channel. Modulated by the P T -symmetric single-well or multi-well Scarf-II potentials, the system is numerically shown to possess stable soliton solutions. Via adiabatical change of system parameters, numerical simulations for the excitation and evolution of nonlinear modes are also performed. The second one is a combination of P T -symmetric models which are coupled via three-wave interactions. Families of nonlinear modes are found with some particular choices of parameters. Stable and unstable nonlinear modes are shown in distinct families by means of numerical simulations. These results will be useful to further investigate nonlinear modes in three-wave interaction models.

  12. Prevention of fatal arrhythmias in high-risk subjects by fish oil n-3 fatty acid intake.

    Science.gov (United States)

    Leaf, Alexander; Albert, Christine M; Josephson, Mark; Steinhaus, David; Kluger, Jeffrey; Kang, Jing X; Cox, Benjamin; Zhang, Hui; Schoenfeld, David

    2005-11-01

    The long-chain n-3 fatty acids in fish have been demonstrated to have antiarrhythmic properties in experimental models and to prevent sudden cardiac death in a randomized trial of post-myocardial infarction patients. Therefore, we hypothesized that these n-3 fatty acids might prevent potentially fatal ventricular arrhythmias in high-risk patients. Four hundred two patients with implanted cardioverter/defibrillators (ICDs) were randomly assigned to double-blind treatment with either a fish oil or an olive oil daily supplement for 12 months. The primary end point, time to first ICD event for ventricular tachycardia or fibrillation (VT or VF) confirmed by stored electrograms or death from any cause, was analyzed by intention to treat. Secondary analyses were performed for "probable" ventricular arrhythmias, "on-treatment" analyses for all subjects who had taken any of their oil supplements, and "on-treatment" analyses only of those subjects who were on treatment for at least 11 months. Compliance with double-blind treatment was similar in the 2 groups; however, the noncompliance rate was high (35% of all enrollees). In the primary analysis, assignment to treatment with the fish oil supplement showed a trend toward a prolonged time to the first ICD event (VT or VF) or of death from any cause (risk reduction of 28%; P=0.057). When therapies for probable episodes of VT or VF were included, the risk reduction became significant at 31%; P=0.033. For those who stayed on protocol for at least 11 months, the antiarrhythmic benefit of fish oil was improved for those with confirmed events (risk reduction of 38%; P=0.034). Although significance was not achieved for the primary end point, this study provides evidence that for individuals at high risk of fatal ventricular arrhythmias, regular daily ingestion of fish oil fatty acids may significantly reduce potentially fatal ventricular arrhythmias.

  13. P-wave and surface wave survey for permafrost analysis in alpine regions

    Science.gov (United States)

    Godio, A.; Socco, L. V.; Garofalo, F.; Arato, A.; Théodule, A.

    2012-04-01

    of seismic data involved the tomographic interpretation of traveltime P-wave first arrivals by considering the continuous refraction of the ray-paths. Several surface-wave dispersion curves were extracted in f-k domain along the seismic line and then inverted through a laterally constrained inversion algorithm to obtain a pseudo-2D section of S-wave velocity. Georadar investigation (about 2 km of georadar lines in the first site) confirmed the presence both of fine and coarse sediments in the uppermost layer; the seismic data allowed the moraines to be characterized down to 20-25 meters of depth. At the elevation of 2700 m asl, we observed a general decrease of the P-wave traveltimes collected in November, when the near surface layer was in frozen condition, respect to the data acquired in June. The frozen layer is responsible of the inversion of P-wave velocity with depth; the higher velocity layer (frozen) cannot be detected in the tomographic interpretation of refraction tomographic of the P-wave arrivals. Compressional wave velocity ranges from 700 m/s on the uppermost part, to 2000-2500 m/s in the internal part of the sediments reaching values higher than 5000 m/s at depth about 20 m. The analysis of surface wave permitted to estimate a slight increase from summer to winter of the S-wave velocity, in the depth range between 0 to 5 m.

  14. Study of NΣ cusp in p+pp+K{sup +}+Λ with partial wave analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lu, S.; Muenzer, R.; Epple, E.; Fabbietti, L. [Excellenz Cluster Universe, Technische Universitaet Muenchen (Germany); Ritman, J.; Roderburg, E.; Hauenstein, F. [FZ Juelich (Germany); Collaboration: Hades and FOPI Collaboration

    2016-07-01

    In the last years, an analysis of exclusive reaction of p+pp+K{sup +}+Λ has been carried out using Bonn-Gatchina Partial Wave Analysis. In a combined analysis of data from Hades, Fopi, Disto and Cosy-TOF, an energy dependent production process is determined. This analysis has shown that a sufficient description of the p+pp+K{sup +}+Λ is quite challenging due to the presence of resonances N* and interference, which requires Partial Wave Analysis. A pronounced narrow structure is observed in its projection on the pΛ-invariant mass. This peak structure, which appears around the NΣ threshold, has a strongly asymmetric structure and is interpreted a NΣ cusp effect. In this talk, the results from a combined analysis will be shown, with a special focus on the NΣ cusp structure and a description using Flatte parametrization.

  15. Scintigraphic assessment of cardiac sympathetic innervation with I-123-metaiodobenzylguanidine in cardiomyopathy. Special reference to cardiac arrhythmia

    Energy Technology Data Exchange (ETDEWEB)

    Asano, Takahisa; Otsuka, Nobuaki; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Tomomitsu, Tatsushi; Fukunaga, Masao [Kawasaki Medical School, Kurashiki, Okayama (Japan); Morita, Koichi

    1999-07-01

    Cardiac sympathetic imagings with I-123-metaiodobenzylguanidine (MIBG) were carried out in 5 cases with dilated cardiomyopathy (DCM), 26 cases with hypertrophic cardiomyopathy (HCM), and 4 cases without cardiac disease as a control to assess cardiac sympathetic innervation qualitatively and quantitatively, and to clarify the relation of MIBG accumulation to arrhythmia. MIBG scintigraphy was performed at 15 min. (early image) and 4 hr. (delayed image) after intravenous injection of MIBG 111 MBq. The MIBG uptake ratio of mediastinum (H/M) and the cardiac washout rate (WR) from early to delayed images were calculated. On both early and delayed SPECTs, MIBG uptake was assessed by defect scores (DSs). Regarding the cases with HCM, the MIBG uptake ratio, WR, and DS were also compared in cases with and without arrhythmia. In DCM, the MIBG uptake on delayed SPECT was markedly low, the H/M ratio was significantly lower, and the DS was significantly higher than in the control (all p<0.05). As for the WR, there was no significant difference between HCM, DCM and the control. In HCM, significantly reduced MIBG uptake was observed in cases with ventricular techycardia (VT) and in cases with atrial fibrillation (Af), as compared with cases without arrhythmia (all p<0.05). There results suggest that MIBG scintigraphy might be a useful tool in the assessment of cardiac sympathetic abnormalities in cardiomyopathy, especially in cases with arrhythmia. (author)

  16. A Proposal for Cardiac Arrhythmia Classification using Complexity Measures

    Directory of Open Access Journals (Sweden)

    AROTARITEI, D.

    2017-08-01

    Full Text Available Cardiovascular diseases are one of the major problems of humanity and therefore one of their component, arrhythmia detection and classification drawn an increased attention worldwide. The presence of randomness in discrete time series, like those arising in electrophysiology, is firmly connected with computational complexity measure. This connection can be used, for instance, in the analysis of RR-intervals of electrocardiographic (ECG signal, coded as binary string, to detect and classify arrhythmia. Our approach uses three algorithms (Lempel-Ziv, Sample Entropy and T-Code to compute the information complexity applied and a classification tree to detect 13 types of arrhythmia with encouraging results. To overcome the computational effort required for complexity calculus, a cloud computing solution with executable code deployment is also proposed.

  17. Relationship of serum magnesium level and supplemental magnesium dosage with post coronary artery bypass graft surgery arrhythmias

    Directory of Open Access Journals (Sweden)

    Najafi M

    2007-06-01

    Full Text Available Background: Atrial and ventricular arrhythmias are among the most common complications after coronary artery bypass graft (CABG surgery. Previous studies demonstrated that cardiopulmonary bypass itself results in reduced serum magnesium levels. In this study, we evaluated the effect of total blood magnesium level (TMG on the prevention of perioperative arrhythmias with routine regimens of 2-4 grams supplemental magnesium (SMG. Methods: TMG was measured in patients who were scheduled for CABG on three occasions: just before anesthesia, just after entering the intensive care unit (ICU after completion of the sugery, and on the first morning after the operation. Patients were evaluated for primary cardiac rhythm and other variables that could have an influence on the magnesium level, including serum creatinine, urine output in the operating room and diuretic therapy. The SMG dosage was also recorded in the operating room and ICU. Patients were then evaluated for the rate and type of arrhythmia for the next three days. Results: The mean TMG levels in 174 cases were 2.2 (0.5, 2.6 (0.6 and 2.4 (0.6 mg/dl for the three occasions, respectively. The mean SMG was 2.5 (1.2 grams. Of 164 patients, 51 (31% developed the following post-operative arrhythmias: AF (7.3%, non-AF SVA (15.2% and ventricular (16.5%. The mean serum creatinine level and urine output were 1.2 mg/dl and 1800 ml, respectively. Although there was a significant difference between the TMG levels on the three different occasions (P<0.001, all values were within normal range. When we stratified the TMG levels of the patients based on administered SMG, the Mentel-Haenszel test revealed no significant difference between the first and third TMG (P=0.6. Although the TMG levels were higher in arrhythmic patients compared to those without arrhythmia (2.25 vs. 2.14 mg/dl, both values were within the normal range and there was no significant difference between the two groups. Serum creatinine levels

  18. Epidemiology of Arrhythmias in Children

    Directory of Open Access Journals (Sweden)

    R Prem Sekar

    2008-05-01

    Full Text Available Unlike the adult population, arrhythmias occur less commonly in childhood. Only 5% of the emergency hospital admissions in the paediatric population is attributed to symptomatic arrhythmias. Majority of these tend to be accessory pathway mediated supraventricular tachyarrhythmias such as Wolff-Parkinson-White (WPW syndrome, permanent junctional reciprocating tachycardia (PJRT and Mahaim tachycardia. The non accessory pathway mediated supraventricular tachyarrhythmias commonly seen in children are junctional ectopic tachycardia (JET and automatic ectopic atrial tachycardia (AET and occur mostly in the post operative period after intracardiac repair for a structural heart defect. Ventricular tachycardia (VT although uncommon, occurs in the paediatric age group in association with hypertrophic cardiomyopathy (HCM, long QT syndrome (LQTS and Brugada syndrome. Occasionally, VT can also present symptomatically as incessant idiopathic infant ventricular tachycardia, right ventricular outflow tract tachycardia, benign VT, catecholaminic VT, idiopathic left ventricular tachycardia and in post cardiac surgical patients.

  19. Comparison of Wave Energy Transport at the Comets p/Halley and p/Giacobini-Zinner

    Science.gov (United States)

    Sding, A.; Glassmeir, K. H.; Fuselier, S. A.; Neubauer, Fritz M.; Tsurutani, B. T.

    1995-01-01

    Using magnetic field, plasma density and flow observations from spacecraft flybys of two comets, Eler variables are determined in order to study wave propogation directions. We investigate the inbound path of the Giotto spacecraft flyby of comet p/Halley outside the bow shock, and the inbound and outbound path of the ICE spacecraft flyby of comet p/Giacobini-Zinner outsinde of the bow wave.

  20. Evasion of HSR in S-wave charmonium decaying to P-wave light hadrons

    Energy Technology Data Exchange (ETDEWEB)

    Li, Gang [Qufu Normal University, Department of Physics, Qufu (China); Liu, Xiao-Hai [Peking University, Department of Physics and State Key Laboratory of Nuclear Physics and Technology, Beijing (China); Zhao, Qiang [Chinese Academy of Sciences, Institute of High Energy Physics, Beijing (China); CAS, Theoretical Physics Center for Science Facilities, Beijing (China)

    2013-09-15

    The S-wave charmonium decaying to a P-wave and S-wave light hadron pairs are supposed to be suppressed by the helicity selection rule in the perturbative QCD framework. With an effective Lagrangian method, we show that the intermediate charmed meson loops can provide a possible mechanism for the evasion of the helicity selection rule, and result in sizeable decay branching ratios in some of those channels. The theoretical predictions can be examined by the forthcoming BES-III data in the near future. (orig.)

  1. Multi-arrhythmias detection with an XML rule-based system from 12-Lead Electrocardiogram.

    Science.gov (United States)

    Khelassi, Abdeldjalil; Yelles-Chaouche, Sarra-Nassira; Benais, Faiza

    2017-05-01

    The computer-aided detection of cardiac arrhythmias stills a crucial application in medical technologies. The rule based systems RBS ensure a high level of transparency and interpretability of the obtained results. To facilitate the diagnosis of the cardiologists and to reduce the uncertainty made in this diagnosis. In this research article, we have realized a classification and automatic recognition of cardiac arrhythmias, by using XML rules that represent the cardiologist knowledge. Thirteen experiments with different knowledge bases were realized for improving the performance of the used method in the detection of 13 cardiac arrhythmias. In the first 12 experiments, we have designed a specialized knowledge base for each cardiac arrhythmia, which contains just one arrhythmia detection rule. In the last experiment, we applied the knowledge base which contains rules of 12 arrhythmias. We used, for the experiments, an international data set with 279 features and 452 records characterizing 12 leads of ECG signal and social information of patients. The data sets were constructed and published at Bilkent University of Ankara, Turkey. In addition, the second version of the self-developed software "XMLRULE" was used; the software can infer more than one class and facilitate the interpretability of the obtained results. The 12 first experiments give 82.80% of correct detection as the mean of all experiments, the results were between 19% and 100% with a low rate in just one experiment. The last experiment in which all arrhythmias are considered, the results of correct detection was 38.33% with 90.55% of sensibility and 46.24% of specificity. It was clearly show that in these results the good choice of the classification model is very beneficial in terms of performance. The obtained results were better than the published results with other computational methods for the mono class detection, but it was less in multi-class detection. The RBS is the most transparent method for

  2. Automated system for ST segment and arrhythmia analysis in exercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hsia, P.W.; Jenkins, J.M.; Shimoni, Y.; Gage, K.P.; Santinga, J.T.; Pitt, B.

    1986-01-01

    A computer-based system for interpretation of the electrocardiogram (ECG) in the diagnosis of arrhythmia and ST segment abnormality in an exercise system is presented. The system was designed for inclusion in a gamma camera so the ECG diagnosis could be combined with the diagnostic capability of radionuclide ventriculography. Digitized data are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is provided. Each beat is assigned a beat code based on a combination of waveform analysis and RR interval measurement. The waveform analysis employs a new correlation coefficient formula which corrects for baseline wander. Selective signal averaging, in which only normal beats are included, is done for an improved signal-to-noise ratio prior to ST segment analysis. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate have all been automated. ST level and slope measurements are computed on signal-averaged data. Arrhythmia analysis of 13 passages of abnormal rhythm by computer was found to be correct in 98.4 percent of all beats. 25 passages of exercise data, 1-5 min in length, were evaluated by the cardiologist and found to be in agreement in 95.8 percent in measurements of ST level and 91.7 percent in measurements of ST slope

  3. Longitudinal evaluation of P-wave dispersion and P-wave maximum in children after transcatheter device closure of secundum atrial septal defect.

    Science.gov (United States)

    Grignani, Robert Teodoro; Tolentino, Kim Martin; Rajgor, Dimple Dayaram; Quek, Swee Chye

    2015-06-01

    Transcatheter device closure of the secundum atrial septal defect (ASD) in children prevents atrial arrhythmias in older age. However, the benefits of favourable atrial electrocardiographic markers in these children remain elusive. We aimed to review the electrocardiographic markers of atrial activity in a longitudinal fashion. We retrospectively reviewed longitudinal data of all children who underwent transcatheter device closure at the National University Hospital between 2004 and 2013. The inclusion criteria included the presence of a secundum-type ASD with left to right shunt and evidence of increased right ventricular volume load (Q p/Q s ratio >1.5 and/or right ventricular dilatation). A total of 25 patients with a mean follow-up of 44.7 ± 33.47 (7.3-117.4) months were included. P maximum and P dispersion decreased at 2 months, P amplitude at 1 week and remained so until last follow-up. A positive trend was seen with a correlation coefficient of +0.12 for P maximum, +0.08 for P dispersion and 0.34 for P amplitude. There was a higher baseline P amplitude and P dispersion in patients who were older than 10 years and a non-significant trend to support an increase in both P maximum (71.0 ± 8.8 vs. 73.2 ± 12.7), P dispersion (17.0 ± 6.5 vs. 22.0 ± 11.3) and P amplitude (0.88 ± 0.25 vs. 1.02 ± 0.23) in patients with an ASD more than 15 mm compared with an ASD <15 mm. There is reduction in both P maximum and P dispersion as early as 2 months, which persisted on follow-up. Earlier closure may result in more favourable electrocardiographic results.

  4. Temperature effect on microstructure and P-wave propagation in Linyi sandstone

    International Nuclear Information System (INIS)

    Sun, Hui; Sun, Qiang; Deng, Wenni; Zhang, Weiqiang; Lü, Chao

    2017-01-01

    Highlights: • Mass loss rate, P-wave velocity change rate and damage factor increase exponentially as temperatures rise. • The damage threshold temperature of sandstone samples is 300 °C and limit temperature is 900 °C. • P-wave velocity change rate of sandstone exhibits excellent linearity with mass loss rate. • Damage factor can be well expressed by mass loss rate. - Abstract: In order to study the effect of high temperature on the sandstone, scanning electron microscope (SEM) experiments and primary wave (P-wave) velocity tests have been carried out on sandstone specimens heated to different temperature. The results showed that: (1) the mass loss rate increases exponentially with the increase of temperature and reaches 2.97% at 900 °C; (2) the P-wave velocity change rate increases exponentially with the increase of temperature while there is some fluctuation before 500 °C; (3) the damage threshold temperature of sandstone samples is 300 °C and the limit temperature is 900 °C; (4) there is a good linear relationship between the mass loss rate and the P-wave velocity change rate, and the correlation coefficient (R) of the fitting line is 0.989; (5) the damage caused by high temperature can be reflected better by the mass loss rate than P-wave velocity change rate. The results obtained in this paper will be good for predicting the properties of sandstone when exposed to high temperature.

  5. Disease and drug-induced arrhythmias : the example of obstructive pulmonary disease

    NARCIS (Netherlands)

    Warnier, M.J.

    2014-01-01

    Notwithstanding the clinical importance of cardiac arrhythmias, relevant information about the background risk and the exact underlying mechanisms of cardiac arrhythmias in patients with obstructive pulmonary disease (asthma and chronic obstructive pulmonary disease [COPD]) is still lacking. The

  6. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  7. Shifts and widths of p-wave confinement induced resonances in atomic waveguides

    International Nuclear Information System (INIS)

    Saeidian, Shahpoor; Melezhik, Vladimir S; Schmelcher, Peter

    2015-01-01

    We develop and analyze a theoretical model to study p-wave Feshbach resonances of identical fermions in atomic waveguides by extending the two-channel model of Lange et al (2009 Phys. Rev. A 79 013622) and Saeidian et al (2012 Phys. Rev. A 86 062713). The experimentally known parameters of Feshbach resonances in free space are used as input of the model. We calculate the shifts and widths of p-wave magnetic Feshbach resonance of 40 K atoms emerging in harmonic waveguides as p-wave confinement induced resonance (CIR). Particularly, we show a possibility to control the width and shift of the p-wave CIR by the trap frequency and the applied magnetic field which could be used in corresponding experiments. Our analysis also demonstrates the importance of the inclusion of the effective range in the computational schemes for the description of the p-wave CIRs contrary to the case of s-wave CIRs where the influence of this term is negligible. (paper)

  8. Associations between high callous-unemotional traits and quality of life across youths with non-conduct disorder diagnoses.

    Science.gov (United States)

    Herpers, Pierre C M; Klip, Helen; Rommelse, Nanda N J; Greven, Corina U; Buitelaar, Jan K

    2016-05-01

    Research regarding callous-unemotional (CU) traits in non-conduct disorder (CD) diagnoses is sparse. We investigated the presence of high CU traits and their associations with quality of life (QoL) in a clinically referred sample of youths with non-CD diagnoses. Parents of 1018 children referred to a child and adolescent psychiatric clinic and rated their child's CU traits and QoL. Experienced clinicians derived DSM-IV-TR diagnoses based on systematic clinical evaluations of these children. High CU traits compared to low CU traits were present in 38.5 % of the sample, and more often in boys than girls (69.4 vs. 30.6 %, p = .004), and were associated with more police contacts (12.2 vs. 3.5 %, p disorder (odds ratio; OR = 1.61; 95 % CI 1.24-2.09; p disorder not otherwise specified/oppositional defiant disorder (OR = 4.98; 95 % CI 2.93-8.64; p disorder (OR = 1.01; 95 % CI .79-1.31; p = .94), were more likely to have high than low CU traits. Those with anxiety/mood disorders were more likely to have low than high CU traits (OR = .59; 95 % CI .42-82; p = .002). In all diagnostic groups, high CU compared to low CU traits were associated with significantly lower QoL, while controlling for gender, age, and comorbidity. As such, high CU traits significantly modify QoL in non-CD disorders.

  9. p-wave pion production from nucleon-nucleon collisions

    International Nuclear Information System (INIS)

    Baru, V.; Epelbaum, E.; Haidenbauer, J.; Hanhart, C.; Kudryavtsev, A. E.; Lensky, V.; Meissner, U.-G.

    2009-01-01

    We investigate p-wave pion production in nucleon-nucleon collisions up to next-to-next-to-leading order in chiral effective field theory. In particular, we show that it is possible to describe simultaneously the p-wave amplitudes in the pn→ppπ - , pp→pnπ + , pp→dπ + channels by adjusting a single low-energy constant accompanying the short-range operator that is available at this order. This study provides a nontrivial test of the applicability of chiral effective field theory to reactions of the type NN→NNπ.

  10. The Relationship Between Aging and P Wave Dispersion

    Directory of Open Access Journals (Sweden)

    İrfan Barutçu

    2009-12-01

    Full Text Available Objective: Atrial fibrillation (AF, commonly observed in advanced ages, displays striking age dependent increase and increased P wave dispersion (PWD has been shown to be a predictor of AF. In this studywe sought to determine whether P wave duration and PWD increase with aging. Method and Results: Eighty-three elderly subjects (group-I mean age 75±8 years and 40 healthy young subjects (group-II, mean age 37±6 years participated in this study. 12-lead ECG recorded at a paper speed of 50mm/s was obtained from each participant. Maximum (Pmax and minimum P wave duration (Pmin was measured manually with a caliper and the difference between two values was defined asPWD. Pmax and PWD were significantly higher in group-I compared to group-II. (98±8 vs. 93±8 p=0.01, 41±12 vs. 34±13 p=0.002, respectively. Among the elderly population when those with cardiovascular disorders such as hypertension, coronary artery disease and heart failure were excluded, Pmax and PWD were still significantly higher than the young population. (Pmax: 98±7 vs. 93±7, p=0.02 and PWD: 42±11 vs. 34±13, p=0.002. Moreover, on correlation analysis a positive correlation was detected between Pmaxand PWD and aging. (r=0.29, p=0.004; r=0.30, p=0.003 respectively.Conclusion: PWD shows age dependent increase and may be a useful marker for estimation the risk of developing AF seen in advanced ages.

  11. Illicit drugs and cardiac arrhythmias in athletes.

    Science.gov (United States)

    Furlanello, Francesco; Serdoz, Laura Vitali; Cappato, Riccardo; De Ambroggi, Luigi

    2007-08-01

    The current management of athletes with cardiac arrhythmias has become complicated by the widespread use of illicit drugs, which can be arrhythmogenic. The World Anti-Doping Agency annually updates a list of prohibited substances and methods banned by the International Olympic Committee that includes different classes of substances namely, anabolic androgenic steroids, hormones and related substances, beta2-agonists, diuretics, stimulants, narcotics, cannabinoids, glucocorticosteroids, alcohol, beta-blockers and others. Almost all illicit drugs may cause, through a direct or indirect arrhythmogenic effect, a wide range of cardiac arrhythmias (focal or reentry type, supraventricular and/or ventricular) that can even be lethal and which are frequently sport activity related. A large use of illicit drugs has been documented in competitive athletes, but the arrhythmogenic effect of specific substances is not precisely known. Precipitation of cardiac arrhythmias, particularly in the presence of a latent electrophysiologic substrate including some inherited cardiomyopathies, at risk of sudden death or due to long-term consumption of the substances, should raise the suspicion that illicit drugs may be a possible cause and lead cardiologists to investigate carefully this relationship and appropriately prevent the clinical consequences.

  12. Waveform inversion for orthorhombic anisotropy with P-waves: feasibility & resolution

    KAUST Repository

    Kazei, Vladimir

    2018-01-27

    Various parameterizations have been suggested to simplify inversions of first arrivals, or Pwaves, in orthorhombic anisotropic media, but the number and type of retrievable parameters have not been decisively determined. We show that only six parameters can be retrieved from the dynamic linearized inversion of Pwaves. These parameters are different from the six parameters needed to describe the kinematics of Pwaves. Reflection-based radiation patterns from the PP scattered waves are remapped into the spectral domain to allow for our resolution analysis based on the effective angle of illumination concept. Singular value decomposition of the spectral sensitivities from various azimuths, offset coverage scenarios, and data bandwidths allows us to quantify the resolution of different parameterizations, taking into account the signal-to-noise ratio in a given experiment. According to our singular value analysis, when the primary goal of inversion is determining the velocity of the Pwaves, gradually adding anisotropy of lower orders (isotropic, vertically transversally isotropic, orthorhombic) in hierarchical parameterization is the best choice. Hierarchical parametrization reduces the tradeoff between the parameters and makes gradual introduction of lower anisotropy orders straightforward. When all the anisotropic parameters affecting Pwave propagation need to be retrieved simultaneously, the classic parameterization of orthorhombic medium with elastic stiffness matrix coefficients and density is a better choice for inversion. We provide estimates of the number and set of parameters that can be retrieved from surface seismic data in different acquisition scenarios. To set up an inversion process, the singular values determine the number of parameters that can be inverted and the resolution matrices from the parameterizations can be used to ascertain the set of parameters that can be resolved.

  13. Gene Therapy in Cardiac Arrhythmias

    Directory of Open Access Journals (Sweden)

    Praveen S.V

    2006-04-01

    Full Text Available Gene therapy has progressed from a dream to a bedside reality in quite a few human diseases. From its first application in adenosine deaminase deficiency, through the years, its application has evolved to vascular angiogenesis and cardiac arrhythmias. Gene based biological pacemakers using viral vectors or mesenchymal cells tested in animal models hold much promise. Induction of pacemaker activity within the left bundle branch can provide stable heart rates. Genetic modification of the AV node mimicking beta blockade can be therapeutic in the management of atrial fibrillation. G protein overexpression to modify the AV node also is experimental. Modification and expression of potassium channel genes altering the delayed rectifier potassium currents may permit better management of congenital long QT syndromes. Arrhythmias in a failing heart are due to abnormal calcium cycling. Potential targets for genetic modulation include the sarcoplasmic reticulum calcium pump, calsequestrin and sodium calcium exchanger.Lastly the ethical concerns need to be addressed.

  14. Anomalous incident-angle and elliptical-polarization rotation of an elastically refracted P-wave

    Science.gov (United States)

    Fa, Lin; Fa, Yuxiao; Zhang, Yandong; Ding, Pengfei; Gong, Jiamin; Li, Guohui; Li, Lijun; Tang, Shaojie; Zhao, Meishan

    2015-08-01

    We report a newly discovered anomalous incident-angle of an elastically refracted P-wave, arising from a P-wave impinging on an interface between two VTI media with strong anisotropy. This anomalous incident-angle is found to be located in the post-critical incident-angle region corresponding to a refracted P-wave. Invoking Snell’s law for a refracted P-wave provides two distinctive solutions before and after the anomalous incident-angle. For an inhomogeneously refracted and elliptically polarized P-wave at the anomalous incident-angle, its rotational direction experiences an acute variation, from left-hand elliptical to right-hand elliptical polarization. The new findings provide us an enhanced understanding of acoustical-wave scattering and lead potentially to widespread and novel applications.

  15. Gated cardiac blood pool studies in arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed [fr

  16. Gated cardiac blood pool studies in arrhythmias

    Energy Technology Data Exchange (ETDEWEB)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed.

  17. High level of oxygen treatment causes cardiotoxicity with arrhythmias and redox modulation

    Energy Technology Data Exchange (ETDEWEB)

    Chapalamadugu, Kalyan C.; Panguluri, Siva K. [Department of Pharmaceutical Sciences, College of Pharmacy, University of South Florida, Tampa, FL (United States); Bennett, Eric S. [Department of Molecular Pharmacology and Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL (United States); Kolliputi, Narasaiah [Division of Allergy and Immunology, Department of Internal Medicine, Morsani College of Medicine, University of South Florida, Tampa, FL (United States); Tipparaju, Srinivas M., E-mail: stippara@health.usf.edu [Department of Pharmaceutical Sciences, College of Pharmacy, University of South Florida, Tampa, FL (United States)

    2015-01-01

    Hyperoxia exposure in mice leads to cardiac hypertrophy and voltage-gated potassium (Kv) channel remodeling. Because redox balance of pyridine nucleotides affects Kv function and hyperoxia alters cellular redox potential, we hypothesized that hyperoxia exposure leads to cardiac ion channel disturbances and redox changes resulting in arrhythmias. In the present study, we investigated the electrical changes and redox abnormalities caused by 72 h hyperoxia treatment in mice. Cardiac repolarization changes were assessed by acquiring electrocardiogram (ECG) and cardiac action potentials (AP). Biochemical assays were employed to identify the pyridine nucleotide changes, Kv1.5 expression and myocardial injury. Hyperoxia treatment caused marked bradycardia, arrhythmia and significantly prolonged (ms) the, RR (186.2 ± 10.7 vs. 146.4 ± 6.2), PR (46.8 ± 3.1 vs. 39.3 ± 1.6), QRS (10.8 ± 0.6 vs. 8.5 ± 0.2), QTc (57.1 ± 3.5 vs. 40 ± 1.4) and JT (13.4 ± 2.1 vs. 7.0 ± 0.5) intervals, when compared with normoxia group. Hyperoxia treatment also induced significant increase in cardiac action potential duration (APD) (ex-APD{sub 90}; 73.8 ± 9.5 vs. 50.9 ± 3.1 ms) and elevated levels of serum markers of myocardial injury; cardiac troponin I (TnI) and lactate dehydrogenase (LDH). Hyperoxia exposure altered cardiac levels of mRNA/protein expression of; Kv1.5, Kvβ subunits and SiRT1, and increased ratios of reduced pyridine nucleotides (NADH/NAD and NADPH/NADP). Inhibition of SiRT1 in H9C2 cells using Splitomicin resulted in decreased SiRT1 and Kv1.5 expression, suggesting that SiRT1 may mediate Kv1.5 downregulation. In conclusion, the cardiotoxic effects of hyperoxia exposure involve ion channel disturbances and redox changes resulting in arrhythmias. - Highlights: • Hyperoxia treatment leads to arrhythmia with prolonged QTc and action potential duration. • Hyperoxia treatment alters cardiac pyridine nucleotide [NAD(P)H/NAD(P)] levels. • SiRT1 and Kv1.5 are co

  18. High level of oxygen treatment causes cardiotoxicity with arrhythmias and redox modulation

    International Nuclear Information System (INIS)

    Chapalamadugu, Kalyan C.; Panguluri, Siva K.; Bennett, Eric S.; Kolliputi, Narasaiah; Tipparaju, Srinivas M.

    2015-01-01

    Hyperoxia exposure in mice leads to cardiac hypertrophy and voltage-gated potassium (Kv) channel remodeling. Because redox balance of pyridine nucleotides affects Kv function and hyperoxia alters cellular redox potential, we hypothesized that hyperoxia exposure leads to cardiac ion channel disturbances and redox changes resulting in arrhythmias. In the present study, we investigated the electrical changes and redox abnormalities caused by 72 h hyperoxia treatment in mice. Cardiac repolarization changes were assessed by acquiring electrocardiogram (ECG) and cardiac action potentials (AP). Biochemical assays were employed to identify the pyridine nucleotide changes, Kv1.5 expression and myocardial injury. Hyperoxia treatment caused marked bradycardia, arrhythmia and significantly prolonged (ms) the, RR (186.2 ± 10.7 vs. 146.4 ± 6.2), PR (46.8 ± 3.1 vs. 39.3 ± 1.6), QRS (10.8 ± 0.6 vs. 8.5 ± 0.2), QTc (57.1 ± 3.5 vs. 40 ± 1.4) and JT (13.4 ± 2.1 vs. 7.0 ± 0.5) intervals, when compared with normoxia group. Hyperoxia treatment also induced significant increase in cardiac action potential duration (APD) (ex-APD 90 ; 73.8 ± 9.5 vs. 50.9 ± 3.1 ms) and elevated levels of serum markers of myocardial injury; cardiac troponin I (TnI) and lactate dehydrogenase (LDH). Hyperoxia exposure altered cardiac levels of mRNA/protein expression of; Kv1.5, Kvβ subunits and SiRT1, and increased ratios of reduced pyridine nucleotides (NADH/NAD and NADPH/NADP). Inhibition of SiRT1 in H9C2 cells using Splitomicin resulted in decreased SiRT1 and Kv1.5 expression, suggesting that SiRT1 may mediate Kv1.5 downregulation. In conclusion, the cardiotoxic effects of hyperoxia exposure involve ion channel disturbances and redox changes resulting in arrhythmias. - Highlights: • Hyperoxia treatment leads to arrhythmia with prolonged QTc and action potential duration. • Hyperoxia treatment alters cardiac pyridine nucleotide [NAD(P)H/NAD(P)] levels. • SiRT1 and Kv1.5 are co-regulated in

  19. Targeting sodium channels in cardiac arrhythmia

    NARCIS (Netherlands)

    Remme, Carol Ann; Wilde, Arthur A. M.

    2014-01-01

    Cardiac voltage-gated sodium channels are responsible for proper electrical conduction in the heart. During acquired pathological conditions and inherited sodium channelopathies, altered sodium channel function causes conduction disturbances and ventricular arrhythmias. Although the clinical,

  20. Barrelet zeros and elastic π+p partial waves

    International Nuclear Information System (INIS)

    Chew, D.M.; Urban, M.

    1976-06-01

    A procedure is proposed for constructing low-order partial-wave amplitudes from a knowledge of Barrelet zeros near the physical region. The method is applied to the zeros already obtained for elastic π + p scattering data between 1.2 and 2.2 GeV cm energies. The partial waves emerge with errors that are straight-forwardly related to the accuracy of the data and satisfy unitarity without any constraint being imposed. There are significant differences from the partial waves obtained by other methods; this can be partially explained by the fact that no previous partial-wave analysis has been able to solve the discrete ambiguity. The cost of the analysis is much less

  1. Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.

    Science.gov (United States)

    Soucek, Filip; Starek, Zdenek

    2018-05-23

    Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  2. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume I P-Wave Measurements in Borehole C4993 Seismic Records, Wave-Arrival Identifications and Interpreted P-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-07-06

    In this volume (I), all P-wave measurements are presented that were performed in Borehole C4993 at the Waste Treatment Plant (WTP) with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver. P-wave measurements were performed over the depth range of 370 to 1400 ft, typically in 10-ft intervals. However, in some interbeds, 5-ft depth intervals were used, while below about 1200 ft, depth intervals of 20 ft were used. Compression (P) waves were generated by moving the base plate of T-Rex for a given number of cycles at a fixed frequency as discussed in Section 2. This process was repeated so that signal averaging in the time domain was performed using 3 to about 15 averages, with 5 averages typically used. In addition to the LBNL 3-D geophone, called the lower receiver herein, a 3-D geophone from Redpath Geophysics was fixed at a depth of 22 ft in Borehole C4993, and a 3-D geophone from the University of Texas was embedded near the borehole at about 1.5 ft below the ground surface. This volume is organized into 12 sections as follows: Section 1: Introduction, Section 2: Explanation of Terminology, Section 3: Vp Profile at Borehole C4993, Sections 4 to 6: Unfiltered P-wave records of lower vertical receiver, reaction mass, and reference receiver, Sections 7 to 9: Filtered P-wave signals of lower vertical receiver, reaction mass and reference receiver, Section 10: Expanded and filtered P-wave signals of lower vertical receiver, and Sections 11 and 12: Waterfall plots of unfiltered and filtered lower vertical receiver signals.

  3. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume III P-Wave Measurements in Borehole C4997 Seismic Records, Wave-Arrival Identifications and Interpreted P-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-06-06

    In this volume (III), all P-wave measurements are presented that were performed in Borehole C4997 at the Waste Treatment Plant (WTP) with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver. P-wave measurements were performed over the depth range of 390 to 1220 ft, typically in 10-ft intervals. However, in some interbeds, 5-ft depth intervals were used. Compression (P) waves were generated by moving the base plate of T-Rex for a given number of cycles at a fixed frequency as discussed in Section 2. This process was repeated so that signal averaging in the time domain was performed using 3 to about 15 averages, with 5 averages typically used. In addition to the LBNL 3-D geophone, called the lower receiver herein, a 3-D geophone from Redpath Geophysics was fixed at a depth of 40 ft (later relocated to 27.5 ft due to visibility in borehole after rain) in Borehole C4997, and a 3-D geophone from the University of Texas was embedded near the borehole at about 1.5 ft below the ground surface. This volume is organized into 12 sections as follows: Section 1: Introduction, Section 2: Explanation of Terminology, Section 3: Vp Profile at Borehole C4997, Sections 4 to 6: Unfiltered P-wave records of lower vertical receiver, reaction mass, and reference receiver, Sections 7 to 9: Filtered P-wave signals of lower vertical receiver, reaction mass and reference receiver, Section 10: Expanded and filtered P-wave signals of lower vertical receiver, and Sections 11 and 12: Waterfall plots of unfiltered and filtered lower vertical receiver signals.

  4. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume II P-Wave Measurements in Borehole C4996 Seismic Records, Wave-Arrival Identifications and Interpreted P-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-07-06

    In this volume (II), all P-wave measurements are presented that were performed in Borehole C4996 at the Waste Treatment Plant (WTP) with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver. P-wave measurements were performed over the depth range of 360 to 1400 ft, typically in 10-ft intervals. However, in some interbeds, 5-ft depth intervals were used, while below about 1180 ft, depth intervals of 20 ft were used. Compression (P) waves were generated by moving the base plate of T-Rex for a given number of cycles at a fixed frequency as discussed in Section 2. This process was repeated so that signal averaging in the time domain was performed using 3 to about 15 averages, with 5 averages typically used. In addition to the LBNL 3-D geophone, called the lower receiver herein, a 3-D geophone from Redpath Geophysics was fixed at a depth of 22 ft in Borehole C4996, and a 3-D geophone from the University of Texas was embedded near the borehole at about 1.5 ft below the ground surface. This volume is organized into 12 sections as follows: Section 1: Introduction, Section 2: Explanation of Terminology, Section 3: Vp Profile at Borehole C4996, Sections 4 to 6: Unfiltered P-wave records of lower vertical receiver, reaction mass, and reference receiver, Sections 7 to 9: Filtered P-wave signals of lower vertical receiver, reaction mass and reference receiver, Section 10: Expanded and filtered P-wave signals of lower vertical receiver, and Sections 11 and 12: Waterfall plots of unfiltered and filtered lower vertical receiver signals.

  5. Scattering amplitude of ultracold atoms near the p-wave magnetic Feshbach resonance

    International Nuclear Information System (INIS)

    Zhang Peng; Naidon, Pascal; Ueda, Masahito

    2010-01-01

    Most of the current theories on the p-wave superfluid in cold atomic gases are based on the effective-range theory for the two-body scattering, where the low-energy p-wave scattering amplitude f 1 (k) is given by f 1 (k)=-1/[ik+1/(Vk 2 )+1/R]. Here k is the incident momentum, V and R are the k-independent scattering volume and effective range, respectively. However, due to the long-range nature of the van der Waals interaction between two colliding ultracold atoms, the p-wave scattering amplitude of the two atoms is not described by the effective-range theory [J. Math. Phys. 4, 54 (1963); Phys. Rev. A 58, 4222 (1998)]. In this paper we provide an explicit calculation for the p-wave scattering of two ultracold atoms near the p-wave magnetic Feshbach resonance. We show that in this case the low-energy p-wave scattering amplitude f 1 (k)=-1/[ik+1/(V eff k 2 )+1/(S eff k)+1/R eff ] where V eff , S eff , and R eff are k-dependent parameters. Based on this result, we identify sufficient conditions for the effective-range theory to be a good approximation of the exact scattering amplitude. Using these conditions we show that the effective-range theory is a good approximation for the p-wave scattering in the ultracold gases of 6 Li and 40 K when the scattering volume is enhanced by the resonance.

  6. The association of air temperature with cardiac arrhythmias

    Science.gov (United States)

    Čulić, Viktor

    2017-11-01

    The body response to meteorological influences may activate pathophysiological mechanisms facilitating the occurrence of cardiac arrhythmias in susceptible patients. Putative underlying mechanisms include changes in systemic vascular resistance and blood pressure, as well as a network of proinflammatory and procoagulant processes. Such a chain reaction probably occurs within the time window of several hours, so use of daily average values of meteorological elements do not seem appropriate for investigation in this area. In addition, overall synoptic situation, and season-specific combinations of meteorological elements and air pollutant levels probably cause the overall effect rather than a single atmospheric element. Particularly strong interrelations have been described among wind speed, air pressure and temperature, relative air humidity, and suspended particulate matter. This may be the main reason why studies examining the association between temperature and ventricular arrhythmias have found linear positive, negative, J-shaped or no association. Further understanding of the pathophysiological adaptation to atmospheric environment may help in providing recommendations for protective measures during "bad" weather conditions in patients with cardiac arrhythmias.

  7. ECG scaling properties of cardiac arrhythmias using detrended fluctuation analysis

    International Nuclear Information System (INIS)

    Rodriguez, E; Echeverria, J C; Alvarez-Ramirez, J; Lerma, C

    2008-01-01

    We applied detrended fluctuation analysis to characterize at very short time scales during episodes of cardiac arrhythmias the raw electrocardiogram (ECG) waveform, aiming to get a global insight into its dynamical behaviour in patients who experienced sudden death. We found that in 15 recordings involving different types of arrhythmias (taken from PhysioNet's Sudden Cardiac Death Holter Database), the ECG waveform, besides showing a less-random dynamics, becomes more regular during bigeminy, ventricular tachycardia or even atrial fibrillation and ventricular fibrillation. The ECG waveform scaling properties thus suggest that reduced complexity dominates the underlying mechanisms of arrhythmias. Among other explanations, this may result from shorted or restricted (i.e. less diverse) pathways of conduction of the electrical activity within ventricles

  8. Design of mm-wave InP DHBT power amplifiers

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Yan, Lei

    2011-01-01

    In this paper suitable topologies for mm-wave integrated power amplifiers using InP DHBT technology is investigated. Among the standard topologies for mm-wave power cells: common-emitter, common-base, and cascode configuration, the cascode configuration proves the most promising in terms of output...

  9. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    International Nuclear Information System (INIS)

    Sultana, R.; Sultana, N.; Rashid, A.; Rasheed, S.Z.; Ahmed, M.; Ishaq, M.; Samad, A.

    2010-01-01

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  10. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sultana, R; Sultana, N; Rashid, A; Rasheed, S Z; Ahmed, M; Ishaq, M; Samad, A [Karachi Institute of Heart Diseases, Karachi (Pakistan)

    2010-10-15

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  11. P-wave dispersion in endogenous and exogenous subclinical hyperthyroidism.

    Science.gov (United States)

    Gen, R; Akbay, E; Camsari, A; Ozcan, T

    2010-02-01

    The aim of this study was to measure maximum P wave duration (Pmax) and P wave dispersion (PWD), which can be indicators for the risk of paroxysmal atrial fibrillation when increased, and to reveal their relationship with thyroid hormone levels in patients with endogenous and exogenous subclinical hyperthyroidism. Seventy-one patients with sublinical thyrotoxicosis (34 endogenous, 37 exogenous) and 69 healthy individuals were enrolled in the study. Pmax and minimum P wave duration (Pmin) on electrocardiogram recordings were measured and PWD was calculated as Pmax-Pmin. Pmax (pendogenous subclinical hyperthyroidism compared with the control group. Pmax (pexogenous subclinical thyrotoxicosis compared with the control group. Pmax (p=0.710) and PWD (p=0.127) were not significantly different in patients with endogenous subclinical hyperthyroidism compared with exogenous subclinical hyperthyroid patients. Pmax and PWD negatively associated with TSH in endogenous and exogenous subclinical hyperthyroidism. In the present study, we observed that Pmax and PWD were longer in patients with endogenous and exogenous subclinical hyperthyroidism. Lack of a difference in Pmax and PWD between patients with endogenous and exogenous subclinical hyperthyroidism seems to support the idea that hormone levels rather than the etiology of thyrotoxicosis affect the heart.

  12. Nonischemic Left Ventricular Scar as a Substrate of Life-Threatening Ventricular Arrhythmias and Sudden Cardiac Death in Competitive Athletes.

    Science.gov (United States)

    Zorzi, Alessandro; Perazzolo Marra, Martina; Rigato, Ilaria; De Lazzari, Manuel; Susana, Angela; Niero, Alice; Pilichou, Kalliopi; Migliore, Federico; Rizzo, Stefania; Giorgi, Benedetta; De Conti, Giorgio; Sarto, Patrizio; Serratosa, Luis; Patrizi, Giampiero; De Maria, Elia; Pelliccia, Antonio; Basso, Cristina; Schiavon, Maurizio; Bauce, Barbara; Iliceto, Sabino; Thiene, Gaetano; Corrado, Domenico

    2016-07-01

    The clinical profile and arrhythmic outcome of competitive athletes with isolated nonischemic left ventricular (LV) scar as evidenced by contrast-enhanced cardiac magnetic resonance remain to be elucidated. We compared 35 athletes (80% men, age: 14-48 years) with ventricular arrhythmias and isolated LV subepicardial/midmyocardial late gadolinium enhancement (LGE) on contrast-enhanced cardiac magnetic resonance (group A) with 38 athletes with ventricular arrhythmias and no LGE (group B) and 40 healthy control athletes (group C). A stria LGE pattern with subepicardial/midmyocardial distribution, mostly involving the lateral LV wall, was found in 27 (77%) of group A versus 0 controls (group C; P<0.001), whereas a spotty pattern of LGE localized at the junction of the right ventricle to the septum was respectively observed in 11 (31%) versus 10 (25%; P=0.52). All athletes with stria pattern showed ventricular arrhythmias with a predominant right bundle branch block morphology, 13 of 27 (48%) showed ECG repolarization abnormalities, and 5 of 27 (19%) showed echocardiographic hypokinesis of the lateral LV wall. The majority of athletes with no or spotty LGE pattern had ventricular arrhythmias with a predominant left bundle branch block morphology and no ECG or echocardiographic abnormalities. During a follow-up of 38±25 months, 6 of 27 (22%) athletes with stria pattern experienced malignant arrhythmic events such as appropriate implantable cardiac defibrillator shock (n=4), sustained ventricular tachycardia (n=1), or sudden death (n=1), compared with none of athletes with no or LGE spotty pattern and controls. Isolated nonischemic LV LGE with a stria pattern may be associated with life-threatening arrhythmias and sudden death in the athlete. Because of its subepicardial/midmyocardial location, LV scar is often not detected by echocardiography. © 2016 The Authors.

  13. P-wave indices in patients with pulmonary emphysema: do P-terminal force and interatrial block have confounding effects?

    Science.gov (United States)

    Chhabra, Lovely; Chaubey, Vinod K; Kothagundla, Chandrasekhar; Bajaj, Rishi; Kaul, Sudesh; Spodick, David H

    2013-01-01

    Pulmonary emphysema causes several electrocardiogram changes, and one of the most common and well known is on the frontal P-wave axis. P-axis verticalization (P-axis > 60°) serves as a quasidiagnostic indicator of emphysema. The correlation of P-axis verticalization with the radiological severity of emphysema and severity of chronic obstructive lung function have been previously investigated and well described in the literature. However, the correlation of P-axis verticalization in emphysema with other P-indices like P-terminal force in V1 (Ptf), amplitude of initial positive component of P-waves in V1 (i-PV1), and interatrial block (IAB) have not been well studied. Our current study was undertaken to investigate the effects of emphysema on these P-wave indices in correlation with the verticalization of the P-vector. Unselected, routinely recorded electrocardiograms of 170 hospitalized emphysema patients were studied. Significant Ptf (s-Ptf) was considered ≥40 mm.ms and was divided into two types based on the morphology of P-waves in V1: either a totally negative (-) P wave in V1 or a biphasic (+/-) P wave in V1. s-Ptf correlated better with vertical P-vectors than nonvertical P-vectors (P = 0.03). s-Ptf also significantly correlated with IAB (P = 0.001); however, IAB and P-vector verticalization did not appear to have any significant correlation (P = 0.23). There was a very weak correlation between i-PV1 and frontal P-vector (r = 0.15; P = 0.047); however, no significant correlation was found between i-PV1 and P-amplitude in lead III (r = 0.07; P = 0.36). We conclude that increased P-tf in emphysema may be due to downward right atrial position caused by right atrial displacement, and thus the common assumption that increased P-tf implies left atrial enlargement should be made with caution in patients with emphysema. Also, the lack of strong correlation between i-PV1 and P-amplitude in lead III or vertical P-vector may suggest the predominant role of downward

  14. Channelopathies - Emerging Trends in The Management of Inherited Arrhythmias

    Directory of Open Access Journals (Sweden)

    Priya Chockalingam, MBBS, MRCPCH, PhD

    2015-01-01

    Full Text Available In spite of their relative rarity, inheritable arrhythmias have come to the forefront as a group of potentially fatal but preventable cause of sudden cardiac death in children and (young adults. Comprehensive management of inherited arrhythmias includes diagnosing and treating the proband and identifying and protecting affected family members. This has been made possible by the vast advances in the field of molecular biology enabling better understanding of the genetic underpinnings of some of these disease groups, namely congenital long QT syndrome, catecholaminergic polymorphic ventricular tachycardia and Brugada syndrome. The ensuing knowledge of the genotype-phenotype correlations enables us to risk-stratify, prognosticate and treat based on the genetic test results. The various diagnostic modalities currently available to us, including clinical tools and genetic technologies, have to be applied judiciously in order to promptly identify those affected and to spare the emotional burden of a potentially lethal disease in the unaffected individuals. The therapeutic armamentarium of inherited arrhythmias includes pharmacological agents, device therapies and surgical interventions. A treatment strategy keeping in mind the risk profile of the patients, the local availability of drugs and the expertise of the treating personnel is proving effective. While opportunities for research are numerous in this expanding field of medicine, there is also tremendous scope for incorporating the emerging trends in managing patients and families with inherited arrhythmias in the Indian subcontinent.

  15. Effect of different doses of oxytocin on cardiac electrophysiology and arrhythmias induced by ischemia.

    Science.gov (United States)

    Houshmand, Fariba; Faghihi, Mahdieh; Imani, Alireza; Kheiri, Soleiman

    2017-01-01

    The onset of acute myocardial ischemia (MI) is accompanied by a rapid increase in electrical instability and often fatal ventricular arrhythmias. This study investigated that whether oxytocin (OT) can modulate ischemia-induced arrhythmias and considered relationships between the severity of arrhythmia and the electrocardiogram parameters during ischemia. OT (0.0001-1 μg) was administrated intraperitoneally 30 min before ischemia. To examine receptor involved, a selective OT-receptor antagonist, atosiban (ATO), was infused 10 min before OT. OT caused a significant and biphasic dose-dependent reduction in ectopic heart activity and arrhythmia score. OT doses that reduced ventricular arrhythmia elicited significant increase in QT interval. OT attenuated the electrophysiological changes associated with MI and there was significant direct relationship between QRS duration and arrhythmia score. ATO treatment reduced beneficial effects of OT on arrhythmogenesis. Nevertheless, ATO failed to alter OT effects on premature ventricular contractions. We assume that the ability of OT to modulate the electrical activity of the heart may play an important role in the antiarrhythmic actions of OT.

  16. Effect of different doses of oxytocin on cardiac electrophysiology and arrhythmias induced by ischemia

    Directory of Open Access Journals (Sweden)

    Fariba Houshmand

    2017-01-01

    Full Text Available The onset of acute myocardial ischemia (MI is accompanied by a rapid increase in electrical instability and often fatal ventricular arrhythmias. This study investigated that whether oxytocin (OT can modulate ischemia-induced arrhythmias and considered relationships between the severity of arrhythmia and the electrocardiogram parameters during ischemia. OT (0.0001–1 μg was administrated intraperitoneally 30 min before ischemia. To examine receptor involved, a selective OT-receptor antagonist, atosiban (ATO, was infused 10 min before OT. OT caused a significant and biphasic dose-dependent reduction in ectopic heart activity and arrhythmia score. OT doses that reduced ventricular arrhythmia elicited significant increase in QT interval. OT attenuated the electrophysiological changes associated with MI and there was significant direct relationship between QRS duration and arrhythmia score. ATO treatment reduced beneficial effects of OT on arrhythmogenesis. Nevertheless, ATO failed to alter OT effects on premature ventricular contractions. We assume that the ability of OT to modulate the electrical activity of the heart may play an important role in the antiarrhythmic actions of OT.

  17. Neutron resonance spectroscopy on 113Cd: The p-wave levels

    International Nuclear Information System (INIS)

    Frankle, C.M.; Bowman, C.D.; Bowman, J.D.; Seestrom, S.J.; Sharapov, E.I.; Popov, Y.P.; Roberson, N.R.

    1992-01-01

    Weak levels in the compound nucleus 114 Cd were located by neutron time-of-flight spectroscopy techniques. Neutron capture measurements were performed with both a natural cadmium target and a highly enriched 113 Cd target. A total of 22 new resonances were located in the neutron energy interval 20-500 eV and were assumed to be p-wave. Resonance parameters, E 0 and gΓ n , are given for the newly identified levels. The p-wave strength function was determined to be 10 4 S 1 =2.8±0.8 and the average level spacing left-angle D 1 right-angle=14 eV. Comparison of the reduced widths with a Porter-Thomas distribution is consistent with having missed 15% of the p-wave levels

  18. Statistical analysis of P-wave neutron reduced widths

    International Nuclear Information System (INIS)

    Joshi, G.C.; Agrawal, H.M.

    2000-01-01

    The fluctuations of the p-wave neutron reduced widths for fifty one nuclei have been analyzed with emphasis on recent measurements by a statistical procedure which is based on the method of maximum likelihood. It is shown that the p-wave neutron reduced widths of even-even nuclei fallow single channel Porter Thomas distribution (χ 2 -distribution with degree of freedom ν=1) for most of the cases where there are no intermediate structure. It is emphasized that the distribution in nuclei other than even-even may differ from a χ 2 -distribution with one degree of freedom. Possible explanation and significance of this deviation from ν=1 is given. (author)

  19. EFFECT OF pH ON ELECTROLESS Ni-P COATING OF CONDUCTIVE AND NON-CONDUCTIVE MATERIALS

    Directory of Open Access Journals (Sweden)

    Subrata Roy

    2011-12-01

    Full Text Available Electroless nickel-phosphorus (Ni-P coating of carbon steel as well as a polypropylene substrate was conducted using sodium hypophosphite as a reducing agent in alkaline media. The influence of pH on coating appearances and the properties of the coatings for both steel and the polypropylene substrate were studied. A nickel-phosphorus coating of good appearance was obtained in the pH range between 5.5 and 12.5 on the carbon steel substrate and between 8.5 and 12 on the polypropylene substrate. The percentage of Ni content in the coating increased with increasing pH of the bath solution. A smooth, uniform microstructure was found in the coating deposited in relatively lower pH solutions compared to higher pH baths. The microhardness of the Ni-P coating decreased with an increasing percentage Ni content in the deposit.

  20. P-wave velocity structure beneath the northern Antarctic Peninsula

    Science.gov (United States)

    Park, Y.; Kim, K.; Jin, Y.

    2010-12-01

    We have imaged tomographically the tree-dimensional velocity structure of the upper mantle beneath the northern Antarctic Peninsula using teleseismic P waves. The data came from the seven land stations of the Seismic Experiment in Patagonia and Antarctica (SEPA) campaigned during 1997-1999, a permanent IRIS/GSN station (PMSA), and 3 seismic stations installed at scientific bases, Esperanza (ESPZ), Jubany (JUBA), and King Sejong (KSJ), in South Shetland Islands. All of the seismic stations are located in coast area, and the signal to noise ratios (SNR) are very low. The P-wave model was inverted from 95 earthquakes resulting in 347 ray paths with P- and PKP-wave arrivals. The inverted model shows a strong low velocity anmaly beneath the Bransfield Strait, and a fast anomaly beneath the South Shetland Islands. The low velocity anomaly beneath the Bransfield might be due to a back arc extension, and the fast velocity anomaly beneath the South Shetland Islands could indicates the cold subducted slab.

  1. Flattening of the electrocardiographic T-wave is a sign of proarrhythmic risk and a reflection of action potential triangulation

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed; Graff, Claus; Kanters, J.K.

    2013-01-01

    Drug-induced triangulation of the cardiac action potential is associated with increased risk of arrhythmic events. It has been suggested that triangulation causes a flattening of the electrocardiographic T-wave but the relationship between triangulation, T-wave flattening and onset of arrhythmia ...

  2. New mechanism of spiral wave initiation in a reaction-diffusion-mechanics system.

    Science.gov (United States)

    Weise, Louis D; Panfilov, Alexander V

    2011-01-01

    Spiral wave initiation in the heart muscle is a mechanism for the onset of dangerous cardiac arrhythmias. A standard protocol for spiral wave initiation is the application of a stimulus in the refractory tail of a propagating excitation wave, a region that we call the "classical vulnerable zone." Previous studies of vulnerability to spiral wave initiation did not take the influence of deformation into account, which has been shown to have a substantial effect on the excitation process of cardiomyocytes via the mechano-electrical feedback phenomenon. In this work we study the effect of deformation on the vulnerability of excitable media in a discrete reaction-diffusion-mechanics (dRDM) model. The dRDM model combines FitzHugh-Nagumo type equations for cardiac excitation with a discrete mechanical description of a finite-elastic isotropic material (Seth material) to model cardiac excitation-contraction coupling and stretch activated depolarizing current. We show that deformation alters the "classical," and forms a new vulnerable zone at longer coupling intervals. This mechanically caused vulnerable zone results in a new mechanism of spiral wave initiation, where unidirectional conduction block and rotation directions of the consequently initiated spiral waves are opposite compared to the mechanism of spiral wave initiation due to the "classical vulnerable zone." We show that this new mechanism of spiral wave initiation can naturally occur in situations that involve wave fronts with curvature, and discuss its relation to supernormal excitability of cardiac tissue. The concept of mechanically induced vulnerability may lead to a better understanding about the onset of dangerous heart arrhythmias via mechano-electrical feedback.

  3. Wave dynamics of generalized continua

    CERN Document Server

    Bagdoev, Alexander G; Shekoyan, Ashot V

    2016-01-01

    This monograph is devoted to problems of propagation and stability of linear and nonlinear waves in continuous media with complex structure. It considers the different media, such as solid with cavities, preliminary deformed disperse medium, solid with porosity filled by the electrically conductive and non-conductive liquid, magnetoelastic, piezo-semiconductors, crystals with dislocations, composites with inclusions, an electrically conductive asymmetrical liquid, a mixture of gas with a drop liquid. The book also considers the propagation of a laser beam through a two-level medium. The presented results are based on methods of evolution and modulation equations that were developed by the authors. The book is intended for scientific and technical researchers, students and post-graduate students specializing in mechanics of continuous media, physical acoustics, and physics of the solid state.

  4. Waveform inversion for orthorhombic anisotropy with P waves: feasibility and resolution

    Science.gov (United States)

    Kazei, Vladimir; Alkhalifah, Tariq

    2018-05-01

    Various parametrizations have been suggested to simplify inversions of first arrivals, or P waves, in orthorhombic anisotropic media, but the number and type of retrievable parameters have not been decisively determined. We show that only six parameters can be retrieved from the dynamic linearized inversion of P waves. These parameters are different from the six parameters needed to describe the kinematics of P waves. Reflection-based radiation patterns from the P-P scattered waves are remapped into the spectral domain to allow for our resolution analysis based on the effective angle of illumination concept. Singular value decomposition of the spectral sensitivities from various azimuths, offset coverage scenarios and data bandwidths allows us to quantify the resolution of different parametrizations, taking into account the signal-to-noise ratio in a given experiment. According to our singular value analysis, when the primary goal of inversion is determining the velocity of the P waves, gradually adding anisotropy of lower orders (isotropic, vertically transversally isotropic and orthorhombic) in hierarchical parametrization is the best choice. Hierarchical parametrization reduces the trade-off between the parameters and makes gradual introduction of lower anisotropy orders straightforward. When all the anisotropic parameters affecting P-wave propagation need to be retrieved simultaneously, the classic parametrization of orthorhombic medium with elastic stiffness matrix coefficients and density is a better choice for inversion. We provide estimates of the number and set of parameters that can be retrieved from surface seismic data in different acquisition scenarios. To set up an inversion process, the singular values determine the number of parameters that can be inverted and the resolution matrices from the parametrizations can be used to ascertain the set of parameters that can be resolved.

  5. P- and S-body wave tomography of the state of Nevada.

    Energy Technology Data Exchange (ETDEWEB)

    Preston, Leiph

    2010-04-01

    P- and S-body wave travel times collected from stations in and near the state of Nevada were inverted for P-wave velocity and the Vp/Vs ratio. These waves consist of Pn, Pg, Sn and Sg, but only the first arriving P and S waves were used in the inversion. Travel times were picked by University of Nevada Reno colleagues and were culled for inclusion in the tomographic inversion. The resulting tomographic model covers the entire state of Nevada to a depth of {approx}90 km; however, only the upper 40 km indicate relatively good resolution. Several features of interest are imaged including the Sierra Nevada, basin structures, and low velocities at depth below Yucca Mountain. These velocity structure images provide valuable information to aide in the interpretation of geothermal resource areas throughout the state on Nevada.

  6. Probing the P -wave charmonium decays of Bc meson

    Science.gov (United States)

    Rui, Zhou

    2018-02-01

    Motivated by the large number of Bc meson decay modes observed recently by several detectors at the LHC, we present a detailed analysis of the Bc meson decaying to the P -wave charmonium states and a light pseudoscalar (P ) or vector (V ) meson within the framework of perturbative QCD factorization. The P -wave charmonium distribution amplitudes are extracted from the n =2 , l =1 Schrödinger states for a Coulomb potential, which can be taken as the universal nonperturbative objects to analyze the hard exclusive processes with P -wave charmonium production. It is found that these decays have large branching ratios of the order of 10-5˜10-2 , which seem to be in the reach of future experiments. We also provide predictions for the polarization fractions and relative phases of Bc→(χc 1,χc 2,hc)V decays. It is expected that the longitudinal polarization amplitudes dominate the branching ratios according to the quark helicity analysis, and the magnitudes and phases of parallel polarization amplitude are approximately equal to the perpendicular ones. The obtained results are compared with available experimental data, our previous studies, and numbers from other approaches.

  7. Shock waves in P-bar target

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Zhijing; Anderson, K.

    1991-11-01

    The deposition of large amount of beam energy in short time will cause high temperature and pressure in the center of P-bar Target, and this disturbance will propagate outwards as a shock wave. Shock wave induced material changes which are of our concern include void growth and accompanying density decrease which will decrease antiproton yield, and crack formation and fracture as was observed in tungsten target which will destroy the integrity of the target. Our objective is to analyze the shock wave behavior in the target, optimize its design so that the destructive effects of shock wave can be minimized, the integrity of the target can be maintained, and a reasonably high yield of antiproton production can be achieved. In this report we put together some results of our analysis of a cylindrical copper target. We hope that it will provide a general overview of the shock wave phenomena in the target, establish a basis for further research, and facilitate the target design. First, energy deposition data are analyzed, and it is justified that as an approximation, the problem can be treated as axi-symmetric. The average data therefore are used as energy profile, however, the maximum energy deposition are still used as the peak value. Next some basic estimations are made as to what temperature and pressure can reach at present level of energy deposition. Then some characteristics of wave propagation in a thermal shock loaded solid are illustrated with a one-dimensional model. Since there is no analytical solution available for cylindrical geometry, our understanding of the problem relies on numerical model, which are performed via finite element package ANSYS. results of numerical analysis are summarized, sources of potential danger are identified, and design ideas to minimize the damage are proposed.

  8. Shock waves in P-bar target

    International Nuclear Information System (INIS)

    Tang, Zhijing; Anderson, K.

    1991-11-01

    The deposition of large amount of beam energy in short time will cause high temperature and pressure in the center of P-bar Target, and this disturbance will propagate outwards as a shock wave. Shock wave induced material changes which are of our concern include void growth and accompanying density decrease which will decrease antiproton yield, and crack formation and fracture as was observed in tungsten target which will destroy the integrity of the target. Our objective is to analyze the shock wave behavior in the target, optimize its design so that the destructive effects of shock wave can be minimized, the integrity of the target can be maintained, and a reasonably high yield of antiproton production can be achieved. In this report we put together some results of our analysis of a cylindrical copper target. We hope that it will provide a general overview of the shock wave phenomena in the target, establish a basis for further research, and facilitate the target design. First, energy deposition data are analyzed, and it is justified that as an approximation, the problem can be treated as axi-symmetric. The average data therefore are used as energy profile, however, the maximum energy deposition are still used as the peak value. Next some basic estimations are made as to what temperature and pressure can reach at present level of energy deposition. Then some characteristics of wave propagation in a thermal shock loaded solid are illustrated with a one-dimensional model. Since there is no analytical solution available for cylindrical geometry, our understanding of the problem relies on numerical model, which are performed via finite element package ANSYS. results of numerical analysis are summarized, sources of potential danger are identified, and design ideas to minimize the damage are proposed

  9. Carbon monoxide induces cardiac arrhythmia via induction of the late Na+ current.

    Science.gov (United States)

    Dallas, Mark L; Yang, Zhaokang; Boyle, John P; Boycott, Hannah E; Scragg, Jason L; Milligan, Carol J; Elies, Jacobo; Duke, Adrian; Thireau, Jérôme; Reboul, Cyril; Richard, Sylvain; Bernus, Olivier; Steele, Derek S; Peers, Chris

    2012-10-01

    Clinical reports describe life-threatening cardiac arrhythmias after environmental exposure to carbon monoxide (CO) or accidental CO poisoning. Numerous case studies describe disruption of repolarization and prolongation of the QT interval, yet the mechanisms underlying CO-induced arrhythmias are unknown. To understand the cellular basis of CO-induced arrhythmias and to identify an effective therapeutic approach. Patch-clamp electrophysiology and confocal Ca(2+) and nitric oxide (NO) imaging in isolated ventricular myocytes was performed together with protein S-nitrosylation to investigate the effects of CO at the cellular and molecular levels, whereas telemetry was used to investigate effects of CO on electrocardiogram recordings in vivo. CO increased the sustained (late) component of the inward Na(+) current, resulting in prolongation of the action potential and the associated intracellular Ca(2+) transient. In more than 50% of myocytes these changes progressed to early after-depolarization-like arrhythmias. CO elevated NO levels in myocytes and caused S-nitrosylation of the Na(+) channel, Na(v)1.5. All proarrhythmic effects of CO were abolished by the NO synthase inhibitor l-NAME, and reversed by ranolazine, an inhibitor of the late Na(+) current. Ranolazine also corrected QT variability and arrhythmias induced by CO in vivo, as monitored by telemetry. Our data indicate that the proarrhythmic effects of CO arise from activation of NO synthase, leading to NO-mediated nitrosylation of Na(V)1.5 and to induction of the late Na(+) current. We also show that the antianginal drug ranolazine can abolish CO-induced early after-depolarizations, highlighting a novel approach to the treatment of CO-induced arrhythmias.

  10. Ventricular arrhythmias in the absence of structural heart disease.

    Science.gov (United States)

    Prystowsky, Eric N; Padanilam, Benzy J; Joshi, Sandeep; Fogel, Richard I

    2012-05-15

    Ventricular arrhythmia (VA) in structurally normal hearts can be broadly considered under non-life-threatening monomorphic and life-threatening polymorphic rhythms. Monomorphic VA is classified on the basis of site of origin in the heart, and the most common areas are the ventricular outflow tracts and left ventricular fascicles. The morphology of the QRS complexes on electrocardiogram is an excellent tool to identify the site of origin of the rhythm. Although these arrhythmias are common and generally carry an excellent prognosis, rare sudden death events have been reported. Very frequent ventricular ectopy may also result in a cardiomyopathy in a minority of patients. Suppression of VA may be achieved using calcium-channel blockers, beta-adrenergic blockers, and class I or III antiarrhythmic drugs. Radiofrequency ablation has emerged as an excellent option to eliminate these arrhythmias, although certain foci including aortic cusps and epicardium may be technically challenging. Polymorphic ventricular tachycardia (VT) is rare and generally occurs in patients with genetic ion channel disorders including long QT syndrome, Brugada syndrome, catecholaminergic polymorphic VT, and short QT syndrome. Unlike monomorphic VT, these arrhythmic syndromes are associated with sudden death. While the cardiac gross morphology is normal, suggesting a structurally normal heart, abnormalities exist at the molecular level and predispose them to arrhythmias. Another fascinating area, idiopathic ventricular fibrillation and early repolarization syndrome, are undergoing research for a genetic basis. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  12. Protective effects of isorhynchophylline on cardiac arrhythmias in rats and guinea pigs.

    Science.gov (United States)

    Gan, Runtao; Dong, Guo; Yu, Jiangbo; Wang, Xu; Fu, Songbin; Yang, Shusen

    2011-09-01

    As one important constituent extracted from a traditional Chinese medicine, Uncaria Rhynchophylla Miq Jacks, isorhynchophylline has been used to treat hypertension, epilepsy, headache, and other illnesses. Whether isorhynchophylline protects hearts against cardiac arrhythmias is still incompletely investigated. This study was therefore aimed to examine the preventive effects of isorhynchophylline on heart arrhythmias in guinea pigs and rats and then explore their electrophysiological mechanisms. In vivo, ouabain and calcium chloride were used to establish experimental arrhythmic models in guinea pigs and rats. In vitro, the whole-cell patch-lamp technique was used to study the effect of isorhynchophylline on action potential duration and calcium channels in acutely isolated guinea pig and rat cardiomyocytes. The dose of ouabain required to induce cardiac arrhythmias was much larger in guinea pigs administered with isorhynchophylline. Additionally, the onset time of cardiac arrhythmias induced by calcium chloride was prolonged, and the duration was shortened in rats pretreated with isorhynchophylline. The further study showed that isorhynchophylline could significantly decrease action potential duration and inhibit calcium currents in isolated guinea pig and rat cardiomyocytes in a dose-dependent manner. In summary, isorhynchophylline played a remarkably preventive role in cardiac arrhythmias through the inhibition of calcium currents in rats and guinea pigs. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Energy-Saving Sintering of Electrically Conductive Powders by Modified Pulsed Electric Current Heating Using an Electrically Nonconductive Die

    Science.gov (United States)

    Ito, Mikio; Kawahara, Kenta; Araki, Keita

    2014-04-01

    Sintering of Cu and thermoelectric Ca3Co4O9 was tried using a modified pulsed electric current sintering (PECS) process, where an electrically nonconductive die was used instead of a conventional graphite die. The pulsed electric current flowed through graphite punches and sample powder, which caused the Joule heating of the powder compact itself, resulting in sintering under smaller power consumption. Especially for the Ca3Co4O9 powder, densification during sintering was also accelerated by this modified PECS process.

  14. T wave alternans threshold late after repair of tetralogy of Fallot

    Science.gov (United States)

    Cheung, Michael M H.; Weintraub, Robert G.; Cohen, Richard J.; Karl, Tom R.; Wilkinson, James L.; Davis, Andrew M.

    2002-01-01

    INTRODUCTION: Sustained microvolt-level T wave alternans (TWA) is a marker of increased risk for malignant ventricular arrhythmia. There is a significant risk of arrhythmia and sudden death after repair of congenital heart disease. The aim of this study was to determine the prevalence and characteristics of TWA after repair of tetralogy of Fallot (TOF). METHODS AND RESULTS: TWA was evaluated during bicycle exercise in 49 subjects who had consecutively undergone transatrial-transpulmonary repair. Median values for age, age at repair, and follow-up duration were 14.9 years (11.5-20.8), 1.6 years (0.2-4.9), and 11.6 years (9.4-17.2), respectively. All patients were in New York Heart Association functional class I and were asymptomatic. Median QRS duration was 120 msec (80-150). Sustained TWA was detected in 7 (23%) of 31 subjects with adequate tests. In these 7 subjects, median onset heart rate (HR) was 120 (98-155). Median HR threshold as a percentage of predicted maximum HR (220 - age) was 58% (48-77). Sustained TWA prevalence was not significantly different compared with normal subjects (7/31 vs 9/83; P = 0.1). Onset HR in the TOF group was significantly lower [mean (SD) of 122 (20) vs 139 (12), P < 0.05]. In the TOF group with sustained TWA, the TWA occurred in 4 of 7 at <60% predicted maximum HR versus 1 of 9 normal subjects (P < 0.05); 3 of 7 had onset HR <120 versus 0 of 9 normal subjects (P < 0.03). There was no significant difference in age, gender, transannular patch use, restrictive right ventricular physiology, QRS duration, QTc, QT/QRS dispersion, or nonsustained ventricular tachycardia in subjects with or those without sustained TWA. CONCLUSION: The onset HR for sustained TWA is significantly lower after repair of TOF. Further study is required to determine whether this represents an increased risk for arrhythmia in this patient group.

  15. Real-Time Detection of Rupture Development: Earthquake Early Warning Using P Waves From Growing Ruptures

    Science.gov (United States)

    Kodera, Yuki

    2018-01-01

    Large earthquakes with long rupture durations emit P wave energy throughout the rupture period. Incorporating late-onset P waves into earthquake early warning (EEW) algorithms could contribute to robust predictions of strong ground motion. Here I describe a technique to detect in real time P waves from growing ruptures to improve the timeliness of an EEW algorithm based on seismic wavefield estimation. The proposed P wave detector, which employs a simple polarization analysis, successfully detected P waves from strong motion generation areas of the 2011 Mw 9.0 Tohoku-oki earthquake rupture. An analysis using 23 large (M ≥ 7) events from Japan confirmed that seismic intensity predictions based on the P wave detector significantly increased lead times without appreciably decreasing the prediction accuracy. P waves from growing ruptures, being one of the fastest carriers of information on ongoing rupture development, have the potential to improve the performance of EEW systems.

  16. Risk of arrhythmia induced by psychotropic medications

    DEFF Research Database (Denmark)

    Fanoe, Søren; Kristensen, Diana; Fink-Jensen, Anders

    2014-01-01

    with psychotropic medications. The algorithm integrates the risk categories of the individual drugs and pre-disposing risk factors and suggests a prudent follow-up for patients with an increased risk. We believe this clinically manageable guideline might improve safety in the many and rapidly increasing number...... of the major mental disorders are associated with a large risk of suicide if untreated. The observed risk of malignant arrhythmia associated with treatment with psychotropic drugs calls for clinical guidelines integrating the risk of the individual drug and other potentially interacting risk factors......Several drugs used in the treatment of mental diseases are associated with an increased risk of sudden cardiac death (SCD). A general cause-relationship between the intake of these drugs and SCD is unattainable, but numerous case reports of drug-induced malignant arrhythmia and epidemiological...

  17. Increased P-wave dispersion a risk for atrial fibrillation in adolescents with anorexia nervosa.

    Science.gov (United States)

    Ertuğrul, İlker; Akgül, Sinem; Derman, Orhan; Karagöz, Tevfik; Kanbur, Nuray

    2016-01-01

    Studies have shown that a prolonged P-wave dispersion is a risk factor for the development of atrial fibrillation. The aim of this study was to evaluate P-wave dispersion in adolescents with anorexia nervosa at diagnosis. We evaluated electrocardiographic findings, particularly the P-wave dispersion, at initial assessment in 47 adolescents with anorexia nervosa. Comparison of P-wave dispersion between adolescents with anorexia nervosa and controls showed a statistically significant higher P-wave dispersion in patients with anorexia nervosa (72 ± 16.3 msec) when compared to the control group (43.8 ± 9.5 msec). Percent of body weight lost, lower body mass index, and higher weight loss rate in the patients with anorexia nervosa had no effect on P-wave dispersion. Due to the fact that anorexia nervosa has a high mortality rate we believe that cardiac pathologies such as atrial fibrillation must also be considered in the medical evaluation.

  18. Effect of Cardiac Arrhythmia Simulation on Nursing Students' Knowledge Acquisition and Retention.

    Science.gov (United States)

    Tubaishat, Ahmad; Tawalbeh, Loai I

    2015-09-01

    The realistic and practical environment that simulation provides is an extremely useful part of the teaching process. Simulation is widely used in health and nursing education today. This study aims to evaluate the effect of simulation-based teaching on the acquisition and retention of arrhythmia-related knowledge among nursing students. A randomized controlled design involving a pretest-posttest was used. Nursing students were allocated randomly either to the experimental group (n = 47), who attended simulation scenarios on cardiac arrhythmia, or to the control group (n = 44) who received a traditional lecture on the same topic. A paired t test showed that the mean knowledge score at the posttest was significantly higher than at the pretest for both groups. However, participants in the experimental group demonstrated significantly increased knowledge of cardiac arrhythmia in the first and the second posttest compared with those in the control group. Thus, simulation is superior and significantly improves students' arrhythmia knowledge. © The Author(s) 2014.

  19. Renormalization group approach to a p-wave superconducting model

    International Nuclear Information System (INIS)

    Continentino, Mucio A.; Deus, Fernanda; Caldas, Heron

    2014-01-01

    We present in this work an exact renormalization group (RG) treatment of a one-dimensional p-wave superconductor. The model proposed by Kitaev consists of a chain of spinless fermions with a p-wave gap. It is a paradigmatic model of great actual interest since it presents a weak pairing superconducting phase that has Majorana fermions at the ends of the chain. Those are predicted to be useful for quantum computation. The RG allows to obtain the phase diagram of the model and to study the quantum phase transition from the weak to the strong pairing phase. It yields the attractors of these phases and the critical exponents of the weak to strong pairing transition. We show that the weak pairing phase of the model is governed by a chaotic attractor being non-trivial from both its topological and RG properties. In the strong pairing phase the RG flow is towards a conventional strong coupling fixed point. Finally, we propose an alternative way for obtaining p-wave superconductivity in a one-dimensional system without spin–orbit interaction.

  20. Spiral wave drift and complex-oscillatory spiral waves caused by heterogeneities in two-dimensional in vitro cardiac tissues

    International Nuclear Information System (INIS)

    Woo, Sung-Jae; Hong, Jin Hee; Kim, Tae Yun; Bae, Byung Wook; Lee, Kyoung J

    2008-01-01

    Understanding spiral reentry wave dynamics in cardiac systems is important since it underlies various cardiac arrhythmia including cardiac fibrillation. Primary cultures of dissociated cardiac cells have been a convenient and useful system for studying cardiac wave dynamics, since one can carry out systematic and quantitative studies with them under well-controlled environments. One key drawback of the dissociated cell culture is that, inevitably, some spatial inhomogeneities in terms of cell types and density, and/or the degree of gap junction connectivity, are introduced to the system during the preparation. These unintentional spatial inhomogeneities can cause some non-trivial wave dynamics, for example, the entrainment dynamics among different spiral waves and the generation of complex-oscillatory spiral waves. The aim of this paper is to quantify these general phenomena in an in vitro cardiac system and provide explanations for them with a simple physiological model having some realistic spatial inhomogeneities incorporated

  1. P-wave indices in patients with pulmonary emphysema: do P-terminal force and interatrial block have confounding effects?

    Directory of Open Access Journals (Sweden)

    Chhabra L

    2013-05-01

    Full Text Available Lovely Chhabra,1 Vinod K Chaubey,1 Chandrasekhar Kothagundla,1 Rishi Bajaj,1 Sudesh Kaul,1 David H Spodick2 1Department of Internal Medicine, 2Department of Cardiovascular Diseases, University of Massachusetts Medical School, Worcester, MA, USA Introduction: Pulmonary emphysema causes several electrocardiogram changes, and one of the most common and well known is on the frontal P-wave axis. P-axis verticalization (P-axis > 60° serves as a quasidiagnostic indicator of emphysema. The correlation of P-axis verticalization with the radiological severity of emphysema and severity of chronic obstructive lung function have been previously investigated and well described in the literature. However, the correlation of P-axis verticalization in emphysema with other P-indices like P-terminal force in V1 (Ptf, amplitude of initial positive component of P-waves in V1 (i-PV1, and interatrial block (IAB have not been well studied. Our current study was undertaken to investigate the effects of emphysema on these P-wave indices in correlation with the verticalization of the P-vector. Materials and methods: Unselected, routinely recorded electrocardiograms of 170 hospitalized emphysema patients were studied. Significant Ptf (s-Ptf was considered ≥40 mm.ms and was divided into two types based on the morphology of P-waves in V1: either a totally negative (- P wave in V1 or a biphasic (+/- P wave in V1. Results: s-Ptf correlated better with vertical P-vectors than nonvertical P-vectors (P = 0.03. s-Ptf also significantly correlated with IAB (P = 0.001; however, IAB and P-vector verticalization did not appear to have any significant correlation (P = 0.23. There was a very weak correlation between i-PV1 and frontal P-vector (r = 0.15; P = 0.047; however, no significant correlation was found between i-PV1 and P-amplitude in lead III (r = 0.07; P = 0.36. Conclusion: We conclude that increased P-tf in emphysema may be due to downward right atrial position caused by

  2. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  3. Higher P-Wave Dispersion in Migraine Patients with Higher Number of Attacks

    Directory of Open Access Journals (Sweden)

    A. Koçer

    2012-01-01

    Full Text Available Objective and Aim. An imbalance of the sympathetic system may explain many of the clinical manifestations of the migraine. We aimed to evaluate P-waves as a reveal of sympathetic system function in migraine patients and healthy controls. Materials and Methods. Thirty-five episodic type of migraine patients (complained of migraine during 5 years or more, BMI < 30 kg/m2 and 30 controls were included in our study. We measured P-wave durations (minimum, maximum, and dispersion from 12-lead ECG recording during pain-free periods. ECGs were transferred to a personal computer via a scanner and then used for magnification of x400 by Adobe Photoshop software. Results. P-wave durations were found to be similar between migraine patients and controls. Although P WD (P-wave dispersion was similar, the mean value was higher in migraine subjects. P WD was positively correlated with P max (P<0.01. Attacks number per month and male gender were the factors related to the P WD (P<0.01. Conclusions. Many previous studies suggested that increased sympathetic activity may cause an increase in P WD. We found that P WD of migraine patients was higher than controls, and P WD was related to attacks number per month and male gender. Further studies are needed to explain the chronic effects of migraine.

  4. Risk of Ventricular Arrhythmia with Citalopram and Escitalopram: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Elena Qirjazi

    Full Text Available The risk of ventricular arrhythmia with citalopram and escitalopram is controversial. In this study we investigated the association between these two drugs and the risk of ventricular arrhythmia.We conducted a population-based retrospective cohort study of older adults (mean age 76 years from 2002 to 2012 in Ontario, Canada, newly prescribed citalopram (n = 137 701 or escitalopram (n = 38 436, compared to those prescribed referent antidepressants sertraline or paroxetine (n = 96 620. After inverse probability of treatment weighting using a propensity score, the baseline characteristics of the comparison groups were similar. The primary outcome was a hospital encounter with ventricular arrhythmia within 90 days of a new prescription, assessed using hospital diagnostic codes. The secondary outcome was all-cause mortality within 90 days.Citalopram was associated with a higher risk of a hospital encounter with ventricular arrhythmia compared with referent antidepressants (0.06% vs. 0.04%, relative risk [RR] 1.53, 95% confidence intervals [CI]1.03 to 2.29, and a higher risk of mortality (3.49% vs. 3.12%, RR 1.12, 95% CI 1.06 to 1.18. Escitalopram was not associated with a higher risk of ventricular arrhythmia compared with the referent antidepressants (0.03% vs. 0.04%, RR 0.84, 95% CI 0.42 to 1.68, but was associated with a higher risk of mortality (2.86% vs. 2.63%, RR 1.09, 95% CI 1.01 to 1.18.Among older adults, initiation of citalopram compared to two referent antidepressants was associated with a small but statistically significant increase in the 90-day risk of a hospital encounter for ventricular arrhythmia.

  5. Risk of Ventricular Arrhythmia with Citalopram and Escitalopram: A Population-Based Study.

    Science.gov (United States)

    Qirjazi, Elena; McArthur, Eric; Nash, Danielle M; Dixon, Stephanie N; Weir, Matthew A; Vasudev, Akshya; Jandoc, Racquel; Gula, Lorne J; Oliver, Matthew J; Wald, Ron; Garg, Amit X

    2016-01-01

    The risk of ventricular arrhythmia with citalopram and escitalopram is controversial. In this study we investigated the association between these two drugs and the risk of ventricular arrhythmia. We conducted a population-based retrospective cohort study of older adults (mean age 76 years) from 2002 to 2012 in Ontario, Canada, newly prescribed citalopram (n = 137 701) or escitalopram (n = 38 436), compared to those prescribed referent antidepressants sertraline or paroxetine (n = 96 620). After inverse probability of treatment weighting using a propensity score, the baseline characteristics of the comparison groups were similar. The primary outcome was a hospital encounter with ventricular arrhythmia within 90 days of a new prescription, assessed using hospital diagnostic codes. The secondary outcome was all-cause mortality within 90 days. Citalopram was associated with a higher risk of a hospital encounter with ventricular arrhythmia compared with referent antidepressants (0.06% vs. 0.04%, relative risk [RR] 1.53, 95% confidence intervals [CI]1.03 to 2.29), and a higher risk of mortality (3.49% vs. 3.12%, RR 1.12, 95% CI 1.06 to 1.18). Escitalopram was not associated with a higher risk of ventricular arrhythmia compared with the referent antidepressants (0.03% vs. 0.04%, RR 0.84, 95% CI 0.42 to 1.68), but was associated with a higher risk of mortality (2.86% vs. 2.63%, RR 1.09, 95% CI 1.01 to 1.18). Among older adults, initiation of citalopram compared to two referent antidepressants was associated with a small but statistically significant increase in the 90-day risk of a hospital encounter for ventricular arrhythmia.

  6. Cardiac Arrhythmia Classification by Multi-Layer Perceptron and Convolution Neural Networks

    Directory of Open Access Journals (Sweden)

    Shalin Savalia

    2018-05-01

    Full Text Available The electrocardiogram (ECG plays an imperative role in the medical field, as it records heart signal over time and is used to discover numerous cardiovascular diseases. If a documented ECG signal has a certain irregularity in its predefined features, this is called arrhythmia, the types of which include tachycardia, bradycardia, supraventricular arrhythmias, and ventricular, etc. This has encouraged us to do research that consists of distinguishing between several arrhythmias by using deep neural network algorithms such as multi-layer perceptron (MLP and convolution neural network (CNN. The TensorFlow library that was established by Google for deep learning and machine learning is used in python to acquire the algorithms proposed here. The ECG databases accessible at PhysioBank.com and kaggle.com were used for training, testing, and validation of the MLP and CNN algorithms. The proposed algorithm consists of four hidden layers with weights, biases in MLP, and four-layer convolution neural networks which map ECG samples to the different classes of arrhythmia. The accuracy of the algorithm surpasses the performance of the current algorithms that have been developed by other cardiologists in both sensitivity and precision.

  7. Cardiac Arrhythmia Classification by Multi-Layer Perceptron and Convolution Neural Networks.

    Science.gov (United States)

    Savalia, Shalin; Emamian, Vahid

    2018-05-04

    The electrocardiogram (ECG) plays an imperative role in the medical field, as it records heart signal over time and is used to discover numerous cardiovascular diseases. If a documented ECG signal has a certain irregularity in its predefined features, this is called arrhythmia, the types of which include tachycardia, bradycardia, supraventricular arrhythmias, and ventricular, etc. This has encouraged us to do research that consists of distinguishing between several arrhythmias by using deep neural network algorithms such as multi-layer perceptron (MLP) and convolution neural network (CNN). The TensorFlow library that was established by Google for deep learning and machine learning is used in python to acquire the algorithms proposed here. The ECG databases accessible at PhysioBank.com and kaggle.com were used for training, testing, and validation of the MLP and CNN algorithms. The proposed algorithm consists of four hidden layers with weights, biases in MLP, and four-layer convolution neural networks which map ECG samples to the different classes of arrhythmia. The accuracy of the algorithm surpasses the performance of the current algorithms that have been developed by other cardiologists in both sensitivity and precision.

  8. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    Science.gov (United States)

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  9. Particulate air pollution induces arrhythmia via oxidative stress and calcium calmodulin kinase II activation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin-Bae [The Division of Cardiology, Kyung Hee University College of Medicine, 1 Hoegi-dong, Dongdaemun-Gu, Seoul (Korea, Republic of); Kim, Changsoo [The Department of Preventive Medicine, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Choi, Eunmi [Cardiovascular Research Institute and Severance Biomedical Science Institute, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Park, Sanghoon; Park, Hyelim; Pak, Hui-Nam; Lee, Moon-Hyoung [The Division of Cardiology, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Shin, Dong Chun [The Department of Preventive Medicine, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Hwang, Ki-Chul [Cardiovascular Research Institute and Severance Biomedical Science Institute, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); The Division of Cardiology, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Brain Korea 21 Project for Medical Science, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Joung, Boyoung, E-mail: cby6908@yuhs.ac [The Division of Cardiology, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of)

    2012-02-15

    Ambient particulate matter (PM) can increase the incidence of arrhythmia. However, the arrhythmogenic mechanism of PM is poorly understood. This study investigated the arrhythmogenic mechanism of PM. In Sprague–Dawley rats, QT interval was increased from 115.0 ± 14.0 to 142.1 ± 18.4 ms (p = 0.02) after endotracheal exposure of DEP (200 μg/ml for 30 min, n = 5). Ventricular premature contractions were more frequently observed after DEP exposure (100%) than baseline (20%, p = 0.04). These effects were prevented by pretreatment of N-acetylcysteine (NAC, 5 mmol/L, n = 3). In 12 Langendorff-perfused rat hearts, DEP infusion of 12.5 μg/ml for 20 min prolonged action potential duration (APD) at only left ventricular base increasing apicobasal repolarization gradients. Spontaneous early afterdepolarization (EAD) and ventricular tachycardia (VT) were observed in 8 (67%) and 6 (50%) hearts, respectively, versus no spontaneous triggered activity or VT in any hearts before DEP infusion. DEP-induced APD prolongation, EAD and VT were successfully prevented with NAC (5 mmol/L, n = 5), nifedipine (10 μmol/L, n = 5), and active Ca{sup 2+}/calmodulin-dependent protein kinase II (CaMKII) blockade, KN 93 (1 μmol/L, n = 5), but not by thapsigargin (200 nmol/L) plus ryanodine (10 μmol/L, n = 5) and inactive CaMKII blockade, KN 92 (1 μmol/L, n = 5). In neonatal rat cardiomyocytes, DEP provoked ROS generation in dose dependant manner. DEP (12.5 μg/ml) induced apoptosis, and this effect was prevented by NAC and KN 93. Thus, this study shows that in vivo and vitro exposure of PM induced APD prolongation, EAD and ventricular arrhythmia. These effects might be caused by oxidative stress and CaMKII activation. -- Highlights: ► The ambient PM consistently prolonged repolarization. ► The ambient PM induced triggered activity and ventricular arrhythmia. ► These effects were prevented by antioxidants, I{sub CaL} blockade and CaMKII blockade. ► The ambient PM can induce

  10. New mechanism of spiral wave initiation in a reaction-diffusion-mechanics system.

    Directory of Open Access Journals (Sweden)

    Louis D Weise

    Full Text Available Spiral wave initiation in the heart muscle is a mechanism for the onset of dangerous cardiac arrhythmias. A standard protocol for spiral wave initiation is the application of a stimulus in the refractory tail of a propagating excitation wave, a region that we call the "classical vulnerable zone." Previous studies of vulnerability to spiral wave initiation did not take the influence of deformation into account, which has been shown to have a substantial effect on the excitation process of cardiomyocytes via the mechano-electrical feedback phenomenon. In this work we study the effect of deformation on the vulnerability of excitable media in a discrete reaction-diffusion-mechanics (dRDM model. The dRDM model combines FitzHugh-Nagumo type equations for cardiac excitation with a discrete mechanical description of a finite-elastic isotropic material (Seth material to model cardiac excitation-contraction coupling and stretch activated depolarizing current. We show that deformation alters the "classical," and forms a new vulnerable zone at longer coupling intervals. This mechanically caused vulnerable zone results in a new mechanism of spiral wave initiation, where unidirectional conduction block and rotation directions of the consequently initiated spiral waves are opposite compared to the mechanism of spiral wave initiation due to the "classical vulnerable zone." We show that this new mechanism of spiral wave initiation can naturally occur in situations that involve wave fronts with curvature, and discuss its relation to supernormal excitability of cardiac tissue. The concept of mechanically induced vulnerability may lead to a better understanding about the onset of dangerous heart arrhythmias via mechano-electrical feedback.

  11. Improved bag models of P-wave baryons

    International Nuclear Information System (INIS)

    Wang Fan; Wong Chunwa

    1988-01-01

    Problems in two previous bag-model calculations of P-wave baryon states are pointed out. The two-body matrix elements used in one of these models, the Myhrer-Wroldsen bag model, have now been revised and corrected by Myhrer, Umino and Wroldsen. We use their corrected matrix elements to construct simple bag models in which baryon masses are stabilized against collapse by using a finite pion size. We find that baryon masses in both ground and excited states can be fitted with the same model parameters. Models with small-bag baryons of the type proposed by Brown and Rho are then obtained. Typical bag radii are 0.5 fm for N, 0.6 fm for Δ and 0.7 fm for P-wave nonstrange baryons. In these models, the mixing angles are still unsatisfactory, while inadequacy in the treatment of center-of-mass motion found in an earlier paper persists. These results are briefly discussed. especially in connection with skyrmion models. (orig.)

  12. An acoustic wave equation for pure P wave in 2D TTI media

    KAUST Repository

    Zhan, Ge; Pestana, Reynam C.; Stoffa, Paul L.

    2011-01-01

    In this paper, a pure P wave equation for an acoustic 2D TTI media is derived. Compared with conventional TTI coupled equations, the resulting equation is unconditionally stable due to the complete isolation of the SV wave mode. To avoid numerical dispersion and produce high quality images, the rapid expansion method REM is employed for numerical implementation. Synthetic results validate the proposed equation and show that it is a stable algorithm for modeling and reverse time migration RTM in a TTI media for any anisotropic parameter values. © 2011 Society of Exploration Geophysicists.

  13. Effects of Hydroalcoholic Extract of Cynodon Dactylon (L. Pers. on ISchemia/Reperfusion-Induced Arrhythmias

    Directory of Open Access Journals (Sweden)

    A Garjani

    2008-09-01

    Full Text Available Background and purpose of the study: Probable antiarrhythmic effects of Cynodon dactylon (L. pers. (family Poaceae against ischemia/reperfusion (I/R-induced arrhythmias were investigated in isolated rat heart. Methods: The hearts were subjected to 30min regional ischemia followed by 30min reperfusion and perfused with hydroalcoholic extract of rhizome of C. dactylon (25, 50, 100 and 200µg/ml. Results: During ischemia, the extract produced marked reduction in the number, duration and incidences of ventricular tachycardia (VT at 25 and 50µg/ml (p<0.001 and p<0.01, respectively. Total number of ischemic ventricular ectopic beats (VEBs were lowered by 25-100µg/ml (p<0.001, p<0.001 and p<0.05, respectively. At the reperfusion phase, C. dactylon (25 and 50µg/ml decreased incidence of VT from 100% (control to 13 and 33% (p<0.001 and p<0.05 respectively. Duration and number of VT and total VF incidence were also reduced at the same concentration (p<0.05 for all. Perfusion of the extract (25-100µg/ml was markedly lowered reversible VF duration from 218±99sec to 0 sec, 0 sec and 10±5sec (p<0.01, p<0.01 and p<0.05 respectively. Moreover, C. dactylon (25 and 50µg/ml decreased number of total VEBs from 349±73 to 35±17 (p<0.001 and 66±26 (p<0.01. In this study, it was also shown that perfusion of the extract produced a marked and concentration-dependent positive inotropic effect. Conclusion: The findings of this study indicate that C. dactylon produce protective effects against I/R-induced arrhythmias in isolated rat hearts probably by increase in the myocardial contractility and as a result by improvement of hemodynamic factors.

  14. Morphological variability of the P-wave for premature envision of paroxysmal atrial fibrillation events.

    Science.gov (United States)

    Martínez, Arturo; Alcaraz, Raul; Rieta, Jose J

    2014-01-01

    The present work introduces the first study on the P-wave morphological variability two hours preceding the onset of paroxysmal atrial fibrillation (PAF). The development of non-invasive methods able to track P-wave alterations over time is a clinically relevant tool to anticipate as much as possible the envision of a new PAF episode. This information is essential for further improvement of preventive and patient-tailored treatment strategies, which could avert the loss of sinus rhythm. In this way, risks for the patients could be minimized and their quality of life improved. Recently, the P-wave morphological analysis is drawing increasing attention because differences in morphology can reflect different atrial activation patterns. Indeed, the P-wave morphology study has recently proved to be useful for determining the presence of an underlying pathophysiological condition in patients prone to atrial fibrillation. However, the P-wave morphology variability over time has not been studied yet. In this respect, the present work puts forward some parameters related to the P-wave shape and energy with the ability to quantify non-invasively the notable atrial conduction alterations preceding the onset of PAF. Results showed that P-wave fragmentation and area presented higher variability over time as the onset of PAF approximates. By properly combining these indices, an average global accuracy of 86.33% was achieved to discern between electrocardiogram segments from healthy subjects, far from a PAF episode and less than one hour close to a PAF episode. As a consequence, the P-wave morphology long-term analysis seems to be a useful tool for the non-invasive envision of PAF onset with a reasonable anticipation. Nonetheless, further research is required to corroborate this finding and to validate the capability of the proposed P-wave metrics in the earlier prediction of PAF onset.

  15. Morphological variability of the P-wave for premature envision of paroxysmal atrial fibrillation events

    International Nuclear Information System (INIS)

    Martínez, Arturo; Alcaraz, Raul; Rieta, Jose J

    2014-01-01

    The present work introduces the first study on the P-wave morphological variability two hours preceding the onset of paroxysmal atrial fibrillation (PAF). The development of non-invasive methods able to track P-wave alterations over time is a clinically relevant tool to anticipate as much as possible the envision of a new PAF episode. This information is essential for further improvement of preventive and patient-tailored treatment strategies, which could avert the loss of sinus rhythm. In this way, risks for the patients could be minimized and their quality of life improved. Recently, the P-wave morphological analysis is drawing increasing attention because differences in morphology can reflect different atrial activation patterns. Indeed, the P-wave morphology study has recently proved to be useful for determining the presence of an underlying pathophysiological condition in patients prone to atrial fibrillation. However, the P-wave morphology variability over time has not been studied yet. In this respect, the present work puts forward some parameters related to the P-wave shape and energy with the ability to quantify non-invasively the notable atrial conduction alterations preceding the onset of PAF. Results showed that P-wave fragmentation and area presented higher variability over time as the onset of PAF approximates. By properly combining these indices, an average global accuracy of 86.33% was achieved to discern between electrocardiogram segments from healthy subjects, far from a PAF episode and less than one hour close to a PAF episode. As a consequence, the P-wave morphology long-term analysis seems to be a useful tool for the non-invasive envision of PAF onset with a reasonable anticipation. Nonetheless, further research is required to corroborate this finding and to validate the capability of the proposed P-wave metrics in the earlier prediction of PAF onset. (paper)

  16. In-medium P-wave quarkonium from the complex lattice QCD potential

    International Nuclear Information System (INIS)

    Burnier, Yannis; Kaczmarek, Olaf; Rothkopf, Alexander

    2016-01-01

    We extend our lattice QCD potential based study http://dx.doi.org/10.1007/JHEP12(2015)101 of the in-medium properties of heavy quark bound states to P-wave bottomonium and charmonium. Similar to the behavior found in the S-wave channel their spectra show a characteristic broadening, as well as mass shifts to lower energy with increasing temperature. In contrast to the S-wave states, finite angular momentum leads to the survival of spectral peaks even at temperatures, where the continuum threshold reaches below the bound state remnant mass. We elaborate on the ensuing challenges in defining quarkonium dissolution and present estimates of melting temperatures for the spin averaged χ b and χ c states. As an application to heavy-ion collisions we further estimate the contribution of feed down to S-wave quarkonium through the P-wave states after freezeout.

  17. In-medium P-wave quarkonium from the complex lattice QCD potential

    Energy Technology Data Exchange (ETDEWEB)

    Burnier, Yannis [Institute of Theoretical Physics, EPFL,CH-1015 Lausanne (Switzerland); Kaczmarek, Olaf [Fakultät für Physik, Universität Bielefeld,D-33615 Bielefeld (Germany); Rothkopf, Alexander [Institute for Theoretical Physics, Heidelberg University,Philosophenweg 16, 69120 Heidelberg (Germany)

    2016-10-07

    We extend our lattice QCD potential based study http://dx.doi.org/10.1007/JHEP12(2015)101 of the in-medium properties of heavy quark bound states to P-wave bottomonium and charmonium. Similar to the behavior found in the S-wave channel their spectra show a characteristic broadening, as well as mass shifts to lower energy with increasing temperature. In contrast to the S-wave states, finite angular momentum leads to the survival of spectral peaks even at temperatures, where the continuum threshold reaches below the bound state remnant mass. We elaborate on the ensuing challenges in defining quarkonium dissolution and present estimates of melting temperatures for the spin averaged χ{sub b} and χ{sub c} states. As an application to heavy-ion collisions we further estimate the contribution of feed down to S-wave quarkonium through the P-wave states after freezeout.

  18. Malignant arrhythmia as the first manifestation of Wolff-Parkinson-White syndrome: a case with minimal preexcitation on electrocardiography.

    Science.gov (United States)

    Gungor, B; Alper, A T

    2013-09-01

    Wolff-Parkinson-White (WPW) syndrome is defined as the presence of an accessory atrioventricular pathway which is manifested as delta waves and short PR interval on electrocardiography (ECG). However, some WPW cases do not have typical findings on ECG and may remain undiagnosed unless palpitations occur. Sudden cardiac death may be the first manifestation of WPW and develops mostly secondary to degeneration of atrial fibrillation into ventricular fibrillation. In this report, we present a case of undiagnosed WPW with minimal preexcitation on ECG and who suffered an episode of malignant arrhythmia as the first manifestation of the disease.

  19. P-wave scattering and the distribution of heterogeneity around Etna volcano

    Directory of Open Access Journals (Sweden)

    Toni Zieger

    2016-09-01

    Full Text Available Volcanoes and fault zones are areas of increased heterogeneity in the Earth crust that leads to strong scattering of seismic waves. For the understanding of the volcanic structure and the role of attenuation and scattering processes it is important to investigate the distribution of heterogeneity. We used the signals of air-gun shots to investigate the distribution of heterogeneity around Mount Etna. We devise a new methodology that is based on the coda energy ratio which we define as the ratio between the energy of the direct P-wave and the energy in a later coda window. This is based on the basic assumption that scattering caused by heterogeneity removes energy from the direct P-waves. We show that measurements of the energy ratio are stable with respect to changes of the details of the time windows definitions. As an independent proxy of the scattering strength along the ray path we measure the peak delay time of the direct P-wave. The peak delay time is well correlated with the coda energy ratio. We project the observation in the directions of the incident rays at the stations. Most notably is an area with increased wave scattering in the volcano and east of it. The strong heterogeneity found supports earlier observations and confirms the possibility to use P-wave sources for the determination of scattering properties. We interpret the extension of the highly heterogeneous zone towards the east as a potential signature of inelastic deformation processes induced by the eastward sliding of flank of the volcano.

  20. Numerical solutions of several reflected shock-wave flow fields with nonequilibrium chemical reactions

    Science.gov (United States)

    Hanson, R. K.; Presley, L. L.; Williams, E. V.

    1972-01-01

    The method of characteristics for a chemically reacting gas is used in the construction of the time-dependent, one-dimensional flow field resulting from the normal reflection of an incident shock wave at the end wall of a shock tube. Nonequilibrium chemical reactions are allowed behind both the incident and reflected shock waves. All the solutions are evaluated for oxygen, but the results are generally representative of any inviscid, nonconducting, and nonradiating diatomic gas. The solutions clearly show that: (1) both the incident- and reflected-shock chemical relaxation times are important in governing the time to attain steady state thermodynamic properties; and (2) adjacent to the end wall, an excess-entropy layer develops wherein the steady state values of all the thermodynamic variables except pressure differ significantly from their corresponding Rankine-Hugoniot equilibrium values.

  1. Hypertension and Cardiac Arrhythmias

    DEFF Research Database (Denmark)

    Lip, Gregory Y H; Coca, Antonio; Kahan, Thomas

    2017-01-01

    Hypertension (HTN) is a common cardiovascular risk factor leading to heart failure (HF), coronary artery disease (CAD), stroke, peripheral artery disease and chronic renal failure. Hypertensive heart disease can manifest as many types of cardiac arrhythmias, most commonly being atrial fibrillation......) Council on Hypertension convened a Task Force, with representation from the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE), with the remit of comprehensively reviewing the available evidence...

  2. Determination of Pwave arrival time of acoustic events

    Directory of Open Access Journals (Sweden)

    Matěj Petružálek

    2010-10-01

    Full Text Available The new approach to the P-wave arrival time determination based on acoustic emission data from loading experiments is tested.The algorithm used in this paper is built on the STA/LTA function computed by a convolution that speeds up the computation processvery much. The picking process makes use of shifting of temporary onset until certain conditions are fulfill and as a main decisioncriterion on the threshold exceeding of the STA/LTA derivation function is used. The P-wave onset time is determined in a selectedinterval that corresponds to the theoretical propagation of elastic wave in the rock sample. Results obtained by our algorithm werecorrelated with data acquired manually and a high order statistic software as well.

  3. Exercising arrhythmias and sudden cardiac death in horses: Review of the literature and comparative aspects.

    Science.gov (United States)

    Navas de Solis, C

    2016-07-01

    Arrhythmias are common in equine athletes during and immediately after exercise. Many of these rhythm variations are not clinically relevant. In horses, a link between different exercising arrhythmias and poor performance or between exercising arrhythmias and sudden cardiac death (SCD) is strongly suspected but not fully understood or proven. SCD during races or competitions is rare, but has catastrophic consequences for the safety of the human partner and public perceptions of welfare during equestrian sports. This review summarises current knowledge of equine exercise arrhythmias and their implications in SCD and compares existing principles and recommendations for equine subjects with those for human athletes. © 2016 EVJ Ltd.

  4. P-wave holographic superconductor/insulator phase transitions affected by dark matter sector

    International Nuclear Information System (INIS)

    Rogatko, Marek; Wysokinski, Karol I.

    2016-01-01

    The holographic approach to building the p-wave superconductors results in three different models: the Maxwell-vector, the SU(2) Yang-Mills and the helical. In the probe limit approximation, we analytically examine the properties of the first two models in the theory with dark matter sector. It turns out that the effect of dark matter on the Maxwell-vector p-wave model is the same as on the s-wave superconductor studied earlier. For the non-Abelian model we study the phase transitions between p-wave holographic insulator/superconductor and metal/superconductor. Studies of marginally stable modes in the theory under consideration allow us to determine features of p-wave holographic droplet in a constant magnetic field. The dependence of the superconducting transition temperature on the coupling constant α to the dark matter sector is affected by the dark matter density ρ_D. For ρ_D>ρ the transition temperature is a decreasing function of α. The critical chemical potential μ_c for the quantum phase transition between insulator and metal depends on the chemical potential of dark matter μ_D and for μ_D=0 is a decreasing function of α.

  5. Sevoflurane causes less arrhythmias than desflurane after off-pump coronary artery bypass grafting: A pilot study

    Directory of Open Access Journals (Sweden)

    Hemmerling Thomas

    2010-01-01

    Full Text Available Background: Volatile anesthetics provide myocardial protection during cardiac surgery. Sevoflurane and desflurane are both efficient agents that allow immediate extubation after off-pump coronary artery bypass grafting (OPCABG. This study compared the incidence of arrhythmias after OPCABG with the two agents. Materials and Methods: Forty patients undergoing OPCABG with immediate extubation and perioperative high thoracic analgesia were included in this controlled, double-blind study; anesthesia was either provided using 1 MAC of sevoflurane (SEVO-group or desflurane (DES-group. Monitoring of perioperative arrhythmias was provided by continuous monitoring of the EKG up to 72 hours after surgery, and routine EKG monitoring once every day, until time of discharge. Patient data, perioperative arrhythmias, and myocardial protection (troponin I, CK, CK-MB-ratio, and transesophageal echocardiography examinations were compared using t-test, Fisher′s exact test or two-way analysis of variance for repeated measurements; P < 0.05. Results: Patient data and surgery-related data were similar between the two groups; all the patients were successfully extubated immediately after surgery, with similar emergence times. Supraventricular tachycardia occurred only in the DES-group (5 of 20 patients, atrial fibrillation was significantly more frequent in the DES group versus SEVO-group, at five out of 20 versus one out of 20 patients, respectively. Myocardial protection was equally achieved in both groups. Discussion: Ultra-fast track anesthesia using sevoflurane seems more advantageous than desflurane for anesthesia, for OPCABG, as it is associated with significantly less atrial fibrillation or supraventricular arrhythmias after surgery.

  6. Thyroid hormones and cardiac arrhythmias

    Czech Academy of Sciences Publication Activity Database

    Tribulová, N.; Knezl, V.; Shainberg, A.; Seki, S.; Soukup, Tomáš

    2010-01-01

    Roč. 52, 3-4 (2010), s. 102-112 ISSN 1537-1891 R&D Projects: GA ČR(CZ) GA304/08/0256 Grant - others:VEGA(SK) 2/0049/09; APVV(SK) 51-059505; APVV(SK) 51-017905 Institutional research plan: CEZ:AV0Z50110509 Keywords : thyroid hormone * arrhythmias * ion channels * connexin-43 Subject RIV: FA - Cardiovascular Disease s incl. Cardiotharic Surgery Impact factor: 2.174, year: 2010

  7. Capturing Pain in the Cortex during General Anesthesia: Near Infrared Spectroscopy Measures in Patients Undergoing Catheter Ablation of Arrhythmias.

    Directory of Open Access Journals (Sweden)

    Barry D Kussman

    Full Text Available The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males. Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05 with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia.

  8. Detection and monitoring of shear crack growth using S-P conversion of seismic waves

    Science.gov (United States)

    Modiriasari, A.; Bobet, A.; Pyrak-Nolte, L. J.

    2017-12-01

    A diagnostic method for monitoring shear crack initiation, propagation, and coalescence in rock is key for the detection of major rupture events, such as slip along a fault. Active ultrasonic monitoring was used in this study to determine the precursory signatures to shear crack initiation in pre-cracked rock. Prismatic specimens of Indiana limestone (203x2101x638x1 mm) with two pre-existing parallel flaws were subjected to uniaxial compression. The flaws were cut through the thickness of the specimen using a scroll saw. The length of the flaws was 19.05 mm and had an inclination angle with respect to the loading direction of 30o. Shear wave transducers were placed on each side of the specimen, with polarization parallel to the loading direction. The shear waves, given the geometry of the flaws, were normally incident to the shear crack forming between the two flaws during loading. Shear crack initiation and propagation was detected on the specimen surface using digital image correlation (DIC), while initiation inside the rock was monitored by measuring full waveforms of the transmitted and reflected shear (S) waves across the specimen. Prior to the detection of a shear crack on the specimen surface using DIC, transmitted S waves were converted to compressional (P) waves. The emergence of converted S-P wave occurs because of the presence of oriented microcracks inside the rock. The microcracks coalesce and form the shear crack observed on the specimen surface. Up to crack coalescence, the amplitude of the converted waves increased with shear crack propagation. However, the amplitude of the transmitted shear waves between the two flaws did not change with shear crack initiation and propagation. This is in agreement with the conversion of elastic waves (P- to S-wave or S- to P-wave) observed by Nakagawa et al., (2000) for normal incident waves. Elastic wave conversions are attributed to the formation of an array of oriented microcracks that dilate under shear stress

  9. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    Science.gov (United States)

    Chakraborty, Monisha; Ghosh, Dipak

    2018-04-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  10. Contribution from S and P waves in pp annihilation at rest

    CERN Document Server

    Bendiscioli, G; Fontana, A; Montagna, P; Rotondi, A; Salvini, P; Bertin, A; Bruschi, M; Capponi, M; De Castro, S; Donà, R; Galli, D; Giacobbe, B; Marconi, U; Massa, I; Piccinini, M; Cesari, N S; Spighi, R; Vecchi, S; Vagnoni, V M; Villa, M; Vitale, A; Zoccoli, A; Bianconi, A; Bonomi, G; Lodi-Rizzini, E; Venturelli, L; Zenoni, A; Cicalò, C; De Falco, A; Masoni, A; Puddu, G; Serci, S; Usai, G L; Gorchakov, O E; Prakhov, S N; Rozhdestvensky, A M; Tretyak, V I; Poli, M; Gianotti, P; Guaraldo, C; Lanaro, A; Lucherini, V; Petrascu, C; Kudryavtsev, A E; Balestra, F; Bussa, M P; Busso, L; Cerello, P G; Denisov, O Yu; Ferrero, L; Grasso, A; Maggiora, A; Panzarasa, A; Panzieri, D; Tosello, F; Botta, E; Bressani, Tullio; Calvo, D; Costa, S; D'Isep, D; Feliciello, A; Filippi, A; Marcello, S; Mirfakhraee, N; Agnello, M; Iazzi, F; Minetti, B; Tessaro, S

    2001-01-01

    The annihilation frequencies of 19 pp annihilation reactions at rest obtained in different target densities are analysed in order to determine the values of the P-wave annihilation percentage at each target density and the average hadronic branching ratios from P- and S-states. Both the assumptions of linear dependence of the annihilation frequencies on the P-wave annihilation percentage of the protonium state and the approach with the enhancement factors of Batty (1989) are considered. Furthermore the cases of incompatible measurements are discussed. (55 refs).

  11. Arrhythmia and conduction disorders in acute inferior myocardial infarction with right ventricular involvement

    International Nuclear Information System (INIS)

    Samadikhah, J.; Hakim, S.H.; Azarfarin, R.; Ghaffari, S.

    2007-01-01

    To assess the prognostic impact of Right Ventricular (RV) myocardial involvement in patients with inferior MI. One hundred seventy patients who were admitted to cardiac care unit of Madani Heart Hospital, Tabriz, Iran with the diagnosis of inferior MI with (group 1) or without (group 2) simultaneous involvement of RV were studied from 2005 to 2006. Patients presenting within 12 hours of symptom onset were eligible for inclusion. Those with simultaneous Anterior wall MI, patients undergoing primary percutaneous transluminal coronary angioplasty and those with renal impairment (creatinine >2 mg/dl) were excluded. Eighty eight percent of the patients with RVMI and 75% with isolated inferior MI had some type of arrhythmia. AV block occurred in 42% of the infarctions with RV involvement and only in 29% of the control group. Intra ventricular conduction disturbance (IVCD) also were more frequent in RVMI (29.4% VS 13.1%, p=0.021), especially the RBBB (20% VS 7.4%, P=0.003). Ventricular fibrillation (VF) was observed in 5.2% and 1.2% and ventricular tachycardia in 26% and 12.2% respectively. In 27% of patients with RVMI it was necessary to implant a pacemaker as compared to 10% in control group. Mortality was higher in the patients with inferior infarction extended to the RV (15.3% vs 3.5%., P=0.0001). There was not a meaningful difference in incidence of LBBB between group 1 and 2 (3.1% vs 2.9% P=0.9). Patients with inferior MI who also have RV myocardial involvement are at increased risk of death and arrhythmias. (author)

  12. [Observation of antiarrhythmic effects of Cinnamomum migao H. W. Li on experimental arrhythmia].

    Science.gov (United States)

    Sui, Y; Qiu, D; Xie, C; Chen, K

    1998-08-01

    To investigate the effects of Cinnamomum migao on experimental arrhythmia. Arrhythmic models of mice, rabbits, guinea pigs and rats were built using chloroform(Chl), adrenalin(Adr), strophanthin-K (Spt-K) and barium chloride (BaCl2). The affected animals were divided randomly into three groups: control group, Cinnamomum migao (CV-3) group and mexiletine (MXL) group, so as to observe and compare the antiarrhythmic effects. CV-3 could reduce the incidence of ventricular fibrillation caused by ch1 in mice and the ventricular tachycardia induced by Adr in rabbits, delay the onset time of this arrhythmia, increase the arrhythmic doses of Spt-K in guinea pigs, reduce the incidence of some arrhythmia caused by BaCl2 in rats and slow down their heart rate. CV-3 has obvious antiarrhythmic effects on experimental arrhythmia. The mechanism of these effects is probably related to the arrest of the intraflow of Na+, Ca2+ in the cardiac cells and the depression of their cardiac autoarrhythmicity and conductivity.

  13. Algorithm Indicating Moment of P-Wave Arrival Based on Second-Moment Characteristic

    Directory of Open Access Journals (Sweden)

    Jakub Sokolowski

    2016-01-01

    Full Text Available The moment of P-wave arrival can provide us with many information about the nature of a seismic event. Without adequate knowledge regarding the onset moment, many properties of the events related to location, polarization of P-wave, and so forth are impossible to receive. In order to save time required to indicate P-wave arrival moment manually, one can benefit from automatic picking algorithms. In this paper two algorithms based on a method finding a regime switch point are applied to seismic event data in order to find P-wave arrival time. The algorithms are based on signals transformed via a basic transform rather than on raw recordings. They involve partitioning the transformed signal into two separate series and fitting logarithm function to the first subset (which corresponds to pure noise and therefore it is considered stationary, exponent or power function to the second subset (which corresponds to nonstationary seismic event, and finding the point at which these functions best fit the statistic in terms of sum of squared errors. Effectiveness of the algorithms is tested on seismic data acquired from O/ZG “Rudna” underground copper ore mine with moments of P-wave arrival initially picked by broadly known STA/LTA algorithm and then corrected by seismic station specialists. The results of proposed algorithms are compared to those obtained using STA/LTA.

  14. GENERAL P, TYPE-I S, AND TYPE-II S WAVES IN ANELASTIC SOLIDS; INHOMOGENEOUS WAVE FIELDS IN LOW-LOSS SOLIDS.

    Science.gov (United States)

    Borcherdt, Roger D.; Wennerberg, Leif

    1985-01-01

    The physical characteristics for general plane-wave radiation fields in an arbitrary linear viscoelastic solid are derived. Expressions for the characteristics of inhomogeneous wave fields, derived in terms of those for homogeneous fields, are utilized to specify the characteristics and a set of reference curves for general P and S wave fields in arbitrary viscoelastic solids as a function of wave inhomogeneity and intrinsic material absorption. The expressions show that an increase in inhomogeneity of the wave fields cause the velocity to decrease, the fractional-energy loss (Q** minus **1) to increase, the deviation of maximum energy flow with respect to phase propagation to increase, and the elliptical particle motions for P and type-I S waves to approach circularity. Q** minus **1 for inhomogeneous type-I S waves is shown to be greater than that for type-II S waves, with the deviation first increasing then decreasing with inhomogeneity. The mean energy densities (kinetic, potential, and total), the mean rate of energy dissipation, the mean energy flux, and Q** minus **1 for inhomogeneous waves are shown to be greater than corresponding characteristics for homogeneous waves, with the deviations increasing as the inhomogeneity is increased for waves of fixed maximum displacement amplitude.

  15. Three-Stage InP Submillimeter-Wave MMIC Amplifier

    Science.gov (United States)

    Pukala, David; Samoska, Lorene; Man, King; Gaier, Todd; Deal, William; Lai, Richard; Mei, Gerry; Makishi, Stella

    2008-01-01

    A submillimeter-wave monolithic integrated- circuit (S-MMIC) amplifier has been designed and fabricated using an indium phosphide (InP) 35-nm gate-length high electron mobility transistor (HEMT) device, developed at Northrop Grumman Corporation. The HEMT device employs two fingers each 15 micrometers wide. The HEMT wafers are grown by molecular beam epitaxy (MBE) and make use of a pseudomorphic In0.75Ga0.25As channel, a silicon delta-doping layer as the electron supply, an In0.52Al0.48As buffer layer, and an InP substrate. The three-stage design uses coplanar waveguide topology with a very narrow ground-to-ground spacing of 14 micrometers. Quarter-wave matching transmission lines, on-chip metal-insulator-metal shunt capacitors, series thin-film resistors, and matching stubs were used in the design. Series resistors in the shunt branch arm provide the basic circuit stabilization. The S-MMIC amplifier was measured for S-parameters and found to be centered at 320 GHz with 13-15-dB gain from 300-345 GHz. This chip was developed as part of the DARPA Submillimeter Wave Imaging Focal Plane Technology (SWIFT) program (see figure). Submillimeter-wave amplifiers could enable more sensitive receivers for earth science, planetary remote sensing, and astrophysics telescopes, particularly in radio astronomy, both from the ground and in space. A small atmospheric window at 340 GHz exists and could enable ground-based observations. However, the submillimeter-wave regime (above 300 GHz) is best used for space telescopes as Earth s atmosphere attenuates most of the signal through water and oxygen absorption. Future radio telescopes could make use of S-MMIC amplifiers for wideband, low noise, instantaneous frequency coverage, particularly in the case of heterodyne array receivers.

  16. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 This test method describes an accurate technique for measuring the normal spectral emittance of electrically nonconducting materials in the temperature range from 1000 to 1800 K, and at wavelengths from 1 to 35 μm. It is particularly suitable for measuring the normal spectral emittance of materials such as ceramic oxides, which have relatively low thermal conductivity and are translucent to appreciable depths (several millimetres) below the surface, but which become essentially opaque at thicknesses of 10 mm or less. 1.2 This test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is particularly suitable for research laboratories, where the highest precision and accuracy are desired, and is not recommended for routine production or acceptance testing. Because of its high accuracy, this test method may be used as a reference method to be applied to production and acceptance testing in case of dispute. 1.3 This test metho...

  17. Gene Therapy in Cardiac Arrhythmias

    OpenAIRE

    Praveen, S.V; Francis, Johnson; Venugopal, K

    2006-01-01

    Gene therapy has progressed from a dream to a bedside reality in quite a few human diseases. From its first application in adenosine deaminase deficiency, through the years, its application has evolved to vascular angiogenesis and cardiac arrhythmias. Gene based biological pacemakers using viral vectors or mesenchymal cells tested in animal models hold much promise. Induction of pacemaker activity within the left bundle branch can provide stable heart rates. Genetic modification of the AV...

  18. Long-term neurodevelopmental outcome after fetal arrhythmia

    NARCIS (Netherlands)

    Lopriore, Enrico; Aziz, Muhammed I.; Nagel, Helene T.; Blom, Nico A.; Rozendaal, Lieke; Kanhai, Humphrey H. H.; Vandenbussche, Frank P. H. A.

    2009-01-01

    OBJECTIVE: The purpose of this study was to determine the long-term neurodevelopmental outcome in fetuses with severe tachy- or bradyarrhythmia. STUDY DESIGN: This was a follow-up study to assess the neurologic, mental, and psychomotor development in cases with fetal cardiac arrhythmia. RESULTS: A

  19. Military jet pilots have higher p-wave dispersions compared to the transport aircraft aircrew

    Directory of Open Access Journals (Sweden)

    Mustafa Çakar

    2016-08-01

    Full Text Available Objectives: For the purpose of flight safety military aircrew must be healthy. P-wave dispersion (PWD is the p-wave length difference in an electrocardiographic (ECG examination and represents the risk of developing atrial fibrillation. In the study we aimed at investigating PWD in healthy military aircrew who reported for periodical examinations. Material and Methods: Seventy-five asymptomatic military aircrew were enrolled in the study. All the subjects underwent physical, radiologic and biochemical examinations, and a 12-lead electrocardiography. P-wave dispersions were calculated. Results: The mean age of the study participants was 36.15±8.97 years and the mean p-wave duration was 100.8±12 ms in the whole group. Forty-seven subjects were non-pilot aircrew, and 28 were pilots. Thirteen study subjects were serving in jets, 49 in helicopters, and 13 were transport aircraft pilots. Thirty-six of the helicopter and 11 of the transport aircraft aircrew were non-pilot aircrew. P-wave dispersion was the lowest in the transport aircraft aircrew, and the highest in jet pilots. P-wave dispersions were similar in the pilots and non-pilot aircrew. Twenty-three study subjects were overweight, 19 had thyroiditis, 26 had hepatosteatosis, 4 had hyperbilirubinemia, 2 had hypertension, and 5 had hyperlipidemia. The PWD was significantly associated with thyroid-stimulating hormone (TSH levels. Serum uric acid levels were associated with p-wave durations. Serum TSH levels were the most important predictor of PWD. Conclusions: When TSH levels were associated with PWD, uric acid levels were associated with p-wave duration in the military aircrew. The jet pilots had higher PWDs. These findings reveal that military jet pilots may have a higher risk of developing atrial fibrillation, and PWD should be recorded during periodical examinations.

  20. Non-sedating antihistamine drugs and cardiac arrhythmias -- biased risk estimates from spontaneous reporting systems?

    DEFF Research Database (Denmark)

    De Bruin, M L; van Puijenbroek, E P; Egberts, A C G

    2002-01-01

    AIMS: This study used spontaneous reports of adverse events to estimate the risk for developing cardiac arrhythmias due to the systemic use of non-sedating antihistamine drugs and compared the risk estimate before and after the regulatory action to recall the over-the-counter status of some...... of these drugs. METHODS: All suspected adverse drug reactions (ADRs) reported until July 1999 to the Netherlands Pharmacovigilance Foundation Lareb were used to calculate the ADR reporting odds ratio, defined as the ratio of exposure odds among reported arrhythmia cases, to the exposure odds of other ADRs (non......-sedating antihistamines. In general non-sedating antihistamines are associated with cardiac arrhythmia to a higher extent in comparison with other drugs (ADR reporting odds ratio 2.05 [95% CI: 1.45, 2.89]). The association between arrhythmias and non-sedating antihistamine drugs calculated before 1998...

  1. Non-sedating antihistamine drugs and cardiac arrhythmias -- biased risk estimates from spontaneous reporting systems?

    DEFF Research Database (Denmark)

    De Bruin, M L; van Puijenbroek, E P; Egberts, A C G

    2002-01-01

    of these drugs. METHODS: All suspected adverse drug reactions (ADRs) reported until July 1999 to the Netherlands Pharmacovigilance Foundation Lareb were used to calculate the ADR reporting odds ratio, defined as the ratio of exposure odds among reported arrhythmia cases, to the exposure odds of other ADRs (non......-sedating antihistamines. In general non-sedating antihistamines are associated with cardiac arrhythmia to a higher extent in comparison with other drugs (ADR reporting odds ratio 2.05 [95% CI: 1.45, 2.89]). The association between arrhythmias and non-sedating antihistamine drugs calculated before 1998...

  2. Chronic cardiac arrhythmias produced by focused cobalt-60 gamma irradiation of the canine atria

    International Nuclear Information System (INIS)

    Dick, H.L.H.; Saylor, C.B.; Reeves, M.M.; Davies, M.J.

    1979-01-01

    Cardiac arrhythmias following exposure of the human heart to ionizing radiation have been reported. Earlier experiments involving irradiation of the hearts of various animals failed to consistently produce similar arrhythmias. In the present work, cobalt-60 irradiation was focused on the interatrial septum of the hearts of 12 dogs. Ten animals developed arrhythmias: These were repetive junctional and atrial tachycardias, repetitive atrial fibrillation, and type one, second-degree atrial ventricular block. The duration varied from 1 to 52 days, with onsets varying from 48 to 146 days postirradiation

  3. The impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot.

    Science.gov (United States)

    Ávila, Pablo; Marcotte, François; Dore, Annie; Mercier, Lise-Andrée; Shohoudi, Azadeh; Mongeon, François-Pierre; Mondésert, Blandine; Proietti, Anna; Ibrahim, Reda; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2016-09-15

    Sudden death of presumed arrhythmic etiology is the leading cause of mortality in adults with tetralogy of Fallot. To assess the impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot. Adults with repaired tetralogy of Fallot were randomized in a 2:1 ratio to an open-label trial of standard care versus 12weeks of supervised combined aerobic/resistance training with continuous Holter monitoring. Proportion of premature ventricular complexes (PVC) and runs of non-sustained ventricular tachycardia (NSVT) were assessed by mixed and Poisson regression models with generalized estimating equations for repeated measures. A total of 152 Holters were performed in 17 patients, median age 35 (interquartile range [IQR] 28, 42) years, 65% male, 13 of whom were randomized to exercise training. Baseline characteristics were similar between groups. Exercise training resulted in significant increases in peak oxygen uptake (11±19%, p=0.028), metabolic equivalents (11±18%, p=0.027), and exercise duration (8±10%, p=0.009) compared to no changes in controls. Frequent (≥30 per hour) PVCs were present in 46% of patients, couplets in 62%, and 3 to 7 beat runs of NSVT in 31%. The median proportion of PVCs was 1.93‰ (IQR 0.41, 5.89) at baseline and 1.45‰ (IQR 0.08, 2.76) during the initial exercise session (p=0.722), and remained stable over time (ß coefficient=-0.031, p=0.408). Runs of NSVT decreased significantly over time (ß coefficient=-0.032, p=0.018). In adults with repaired tetralogy of Fallot, exercise training is safe, improves exercise capacity, and appears to confer a beneficial effect on ventricular arrhythmias. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Relation between the behaviors of P-wave and QT dispersions in elderly patients with heart failure

    Directory of Open Access Journals (Sweden)

    Szlejf Cláudia

    2002-01-01

    Full Text Available OBJECTIVE: To assess the relation between P-wave and QT dispersions in elderly patients with heart failure. METHODS: Forty-seven elderly patients (75.6±6 years with stable heart failure in NYHA functional classes II or III and with ejection fractions of 37±6% underwent body surface mapping to analyze P-wave and QT dispersions. The degree of correlation between P-wave and QT dispersions was assessed, and P-wave dispersion values in patients with QT dispersion greater than and smaller than 100 ms were compared. RESULTS: The mean values of P-wave and QT dispersions were 54±14 ms and 68±27 ms, respectively. The correlation between the 2 variables was R=0.41 (p=0.04. In patients with QT dispersion values > 100 ms, P-wave dispersion was significantly greater than in those with QT dispersion values < 100 ms (58±16 vs 53±12 ms, p=0.04 . CONCLUSION: Our results suggest that, in elderly patients with heart failure, a correlation between the values of P-wave and QT dispersions exists. These findings may have etiopathogenic, pathophysiologic, prognostic, and therapeutic implications, which should be investigated in other studies.

  5. Cardiac arrhythmias associated with spinal cord injury

    DEFF Research Database (Denmark)

    Hector, Sven Magnus; Biering-Sørensen, Tor; Krassioukov, Andrei

    2013-01-01

    CONTEXT/OBJECTIVES: To review the current literature to reveal the incidence of cardiac arrhythmias and its relation to spinal cord injury (SCI). METHODS: Data source: MEDLINE database, 304 hits, and 32 articles were found to be relevant. The relevant articles all met the inclusion criteria: (1...

  6. The Effect of PM 10 on Ischemia- Reperfusion Induced Arrhythmias in Rats

    Directory of Open Access Journals (Sweden)

    Esmat Radmanesh

    Full Text Available ABSTRACT Epidemiological studies show that particulate matter (PM is the principal instigator of some adverse clinical symptoms involving cardiovascular diseases. PM exposure can increase experimental infarct size and potentiate myocardial ischemia and arrhythmias in experimental MI models such as ischemia-reperfusion (I/R injury.The present study was aimed to evaluate the effects of particulate matter (PM10 on ischemia- reperfusion induced arrhythmias with emphasis on the protective role of VA as an antioxidant on them. Male Wistar rats were divided into 8 groups (n=10: Control, VAc, Sham, VA, PM1 (0.5 mg/kg, PM2 (2.5 mg/kg, PM3 group (5 mg/kg, PM3 + VA group. Within 48 hours, PM10 was instilled into trachea in two stages. Then the hearts were isolated, transferred to a Langendorff apparatus, and subjected to global ischemia (30 minutes followed by reperfusion (60 minutes. The ischemia- reperfusion induced ventricular arrhythmias were assessed according to the Lambeth conventions.In the present study,the number, incidence and duration of arrhythmiasduring30 minutes ischemia were demonstrated to be more than those in the reperfusion stage. PM exposure increased significantly the number, incidence and duration of arrhythmias in the ischemia and reperfusion duration. Vanillic acid reduced significantly the number, incidence and duration of arrhythmias during the ischemia and reperfusion period.In summary, the results of this study demonstrated that the protective and dysrhythmic effects of VA in the PM exposure rats in I/R model are probably related to its antioxidant properties.

  7. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    Directory of Open Access Journals (Sweden)

    Bohui Zhu

    2013-01-01

    Full Text Available This paper presents a novel maximum margin clustering method with immune evolution (IEMMC for automatic diagnosis of electrocardiogram (ECG arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias.

  8. P-wave excited {B}_{c}^{* * } meson photoproduction at the LHeC

    Science.gov (United States)

    Kai, He; Huan-Yu, Bi; Ren-You, Zhang; Xiao-Zhou, Li; Wen-Gan, Ma

    2018-05-01

    As an important sequential work of the S-wave {B}c(* ) ({}1{S}0({}3{S}1) ) meson production at the large hadron electron collider (LHeC), we investigate the production of the P-wave excited {B}c* * states (1 P 1 and 3 P J with J = 0, 1, 2) via photoproduction mechanism within the framework of nonrelativistic QCD at the LHeC. Generally, the {e}-+P\\to γ +g\\to {B}c* * +b+\\bar{c} process is considered as the main production mechanism at an electron–proton collider due to the large luminosity of the gluon. However, according to our experience on the S-wave {B}c(* ) meson production at the LHeC, the extrinsic production mechanism, i.e., {e}-+P\\to γ +c\\to {B}c* * +b and {e}-+P\\to γ +\\bar{b} \\to {B}c* * +\\bar{c}, could also provide dominating contributions at low p T region. A careful treatment between these channels is performed and the results on total and differential cross sections, together with main uncertainties are discussed. Taking the quark masses m b = 4.90 ± 0.40 GeV and m c = 1.50 ± 0.20 GeV into account and summing up all the production channels, we expect to accumulate ({2.48}-1.75+3.55)× {10}4 {B}c* * ({}1{P}1), ({1.14}-0.82+1.49)× {10}4 {B}c* * ({}3{P}0),({2.38}-1.74+3.39)× {10}4 {B}c* * ({}3{P}1) and ({5.59}-3.93+7.84)× {10}4 {B}c* * ({}3{P}2) events at the \\sqrt{S}=1.30 {{T}}{{e}}{{V}} LHeC in one operation year with luminosity { \\mathcal L }={10}33 cm‑2 s‑1. With such sizable events, it is worth studying the properties of excited P-wave {B}c* * states at the LHeC.

  9. Four-wave mixing and parametric four-wave mixing near the 4P-4S transition of the potassium atom

    International Nuclear Information System (INIS)

    Katharakis, M; Merlemis, N; Serafetinides, A; Efthimiopoulos, T

    2002-01-01

    Potassium 4S 1/2 -6S 1/2 two-photon excitation initiates the emission of several internally generated photons. For the first time two emission lines, one close to and one below the potassium 4P 3/2 level, are reported for low pumping intensity. Radiation emitted below the 4P 3/2 level is due to a parametric four-wave mixing process that uses the photons emitted at the 5P 3/2 -4S 1/2 transition and a two-step four-wave mixing process generates the line emitted close to the 4P 3/2 level

  10. Scattered P'P' waves observed at short distances

    Science.gov (United States)

    Earle, Paul S.; Rost, Sebastian; Shearer, Peter M.; Thomas, Christine

    2011-01-01

    We detect previously unreported 1 Hz scattered waves at epicentral distances between 30° and 50° and at times between 2300 and 2450 s after the earthquake origin. These waves likely result from off-azimuth scattering of PKPbc to PKPbc in the upper mantle and crust and provide a new tool for mapping variations in fine-scale (10 km) mantle heterogeneity. Array beams from the Large Aperture Seismic Array (LASA) clearly image the scattered energy gradually emerging from the noise and reaching its peak amplitude about 80 s later, and returning to the noise level after 150 s. Stacks of transverse versus radial slowness (ρt, ρr) show two peaks at about (2, -2) and (-2,-2) s/°, indicating the waves arrive along the major arc path (180° to 360°) and significantly off azimuth. We propose a mantle and surface PKPbc to PKPbc scattering mechanism for these observations because (1) it agrees with the initiation time and distinctive slowness signature of the scattered waves and (2) it follows a scattering path analogous to previously observed deep-mantle PK•KP scattering (Chang and Cleary, 1981). The observed upper-mantle scattered waves and PK•KP waves fit into a broader set of scattered waves that we call P′•d•P′, which can scatter from any depth, d, in the mantle.

  11. Correlating P-wave Velocity with the Physico-Mechanical Properties of Different Rocks

    Science.gov (United States)

    Khandelwal, Manoj

    2013-04-01

    In mining and civil engineering projects, physico-mechanical properties of the rock affect both the project design and the construction operation. Determination of various physico-mechanical properties of rocks is expensive and time consuming, and sometimes it is very difficult to get cores to perform direct tests to evaluate the rock mass. The purpose of this work is to investigate the relationships between the different physico-mechanical properties of the various rock types with the P-wave velocity. Measurement of P-wave velocity is relatively cheap, non-destructive and easy to carry out. In this study, representative rock mass samples of igneous, sedimentary, and metamorphic rocks were collected from the different locations of India to obtain an empirical relation between P-wave velocity and uniaxial compressive strength, tensile strength, punch shear, density, slake durability index, Young's modulus, Poisson's ratio, impact strength index and Schmidt hammer rebound number. A very strong correlation was found between the P-wave velocity and different physico-mechanical properties of various rock types with very high coefficients of determination. To check the sensitivity of the empirical equations, Students t test was also performed, which confirmed the validity of the proposed correlations.

  12. InP HEMT Integrated Circuits for Submillimeter Wave Radiometers in Earth Remote Sensing

    Science.gov (United States)

    Deal, William R.; Chattopadhyay, Goutam

    2012-01-01

    The operating frequency of InP integrated circuits has pushed well into the Submillimeter Wave frequency band, with amplification reported as high as 670 GHz. This paper provides an overview of current performance and potential application of InP HEMT to Submillimeter Wave radiometers for earth remote sensing.

  13. Emerging molecular therapies targeting myocardial infarction-related arrhythmias

    NARCIS (Netherlands)

    Driessen, Helen E.; van Veen, Toon A. B.; Boink, Gerard J. J.

    2017-01-01

    Cardiac disease is the leading cause of death in the developed world. Ventricular arrhythmias associated with myocardial ischaemia and/or infarction are a major contributor to cardiovascular mortality, and require improved prevention and treatment. Drugs, devices, and radiofrequency catheter

  14. Multiclass Classification of Cardiac Arrhythmia Using Improved Feature Selection and SVM Invariants.

    Science.gov (United States)

    Mustaqeem, Anam; Anwar, Syed Muhammad; Majid, Muahammad

    2018-01-01

    Arrhythmia is considered a life-threatening disease causing serious health issues in patients, when left untreated. An early diagnosis of arrhythmias would be helpful in saving lives. This study is conducted to classify patients into one of the sixteen subclasses, among which one class represents absence of disease and the other fifteen classes represent electrocardiogram records of various subtypes of arrhythmias. The research is carried out on the dataset taken from the University of California at Irvine Machine Learning Data Repository. The dataset contains a large volume of feature dimensions which are reduced using wrapper based feature selection technique. For multiclass classification, support vector machine (SVM) based approaches including one-against-one (OAO), one-against-all (OAA), and error-correction code (ECC) are employed to detect the presence and absence of arrhythmias. The SVM method results are compared with other standard machine learning classifiers using varying parameters and the performance of the classifiers is evaluated using accuracy, kappa statistics, and root mean square error. The results show that OAO method of SVM outperforms all other classifiers by achieving an accuracy rate of 81.11% when used with 80/20 data split and 92.07% using 90/10 data split option.

  15. [P wave dispersion increased in childhood depending on blood pressure, weight, height, and cardiac structure and function].

    Science.gov (United States)

    Chávez-González, Elibet; González-Rodríguez, Emilio; Llanes-Camacho, María Del Carmen; Garí-Llanes, Merlin; García-Nóbrega, Yosvany; García-Sáez, Julieta

    2014-01-01

    Increased P wave dispersion are identified as a predictor of atrial fibrillation. There are associations between hypertension, P wave dispersion, constitutional and echocardiographic variables. These relationships have been scarcely studied in pediatrics. The aim of this study was to determine the relationship between P wave dispersion, blood pressure, echocardiographic and constitutional variables, and determine the most influential variables on P wave dispersion increases in pediatrics. In the frame of the PROCDEC II project, children from 8 to 11 years old, without known heart conditions were studied. Arterial blood pressure was measured in all the children; a 12-lead surface electrocardiogram and an echocardiogram were done as well. Left ventricular mass index mean values for normotensive (25.91±5.96g/m(2.7)) and hypertensive (30.34±8.48g/m(2.7)) showed significant differences P=.000. When we add prehypertensive and hypertensive there are 50.38% with normal left ventricular mass index and P wave dispersion was increased versus 13.36% of normotensive. Multiple regression demonstrated that the mean blood pressure, duration of A wave of mitral inflow, weight and height have a value of r=0.88 as related to P wave dispersion. P wave dispersion is increased in pre- and hypertensive children compared to normotensive. There are pre- and hypertensive patients with normal left ventricular mass index and increased P wave dispersion. Mean arterial pressure, duration of the A wave of mitral inflow, weight and height are the variables with the highest influence on increased P wave dispersion. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  16. Dofetilide: a new drug to control cardiac arrhythmia

    DEFF Research Database (Denmark)

    Elming, Hanne; Brendorp, Bente; Pedersen, Ole Dyg

    2003-01-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. Mortality, and especially morbidity caused by AF, are major and growing health problems in the western world. AF is strongly associated with arterial hypertension, congestive heart failure, valvular heart disease, ischaemic heart...

  17. Surgical outcome of Fontan conversion and arrhythmia surgery: Need a pacemaker?

    Science.gov (United States)

    Terada, Takafumi; Sakurai, Hajime; Nonaka, Toshimichi; Sakurai, Takahisa; Sugiura, Junya; Taneichi, Tetsuyoshi; Ohtsuka, Ryohei

    2014-07-01

    Atrial tachyarrhythmias are frequent complications in the late period after the Fontan procedure, and important risk factors for a poor prognosis. The impact of Fontan conversion and arrhythmia surgery in failed Fontan patients has been described in many reports. We evaluated our experience with Fontan conversion procedures, concomitant arrhythmia surgery, and pacemaker implantation. We reviewed the hospital records of 25 consecutive patients who underwent a Fontan conversion procedure from January 2004 to March 2012. Twenty-four patients had arrhythmia surgery using cryoablation and radiofrequency ablation at the time of conversion. A bilateral atrial maze procedure was performed in 6 patients, right-side maze in 15, and isthmus block in 3. Three patients with a diagnosis of corrected transposition of the great arteries underwent simultaneous pacemaker implantation electively. There was no early death and one late death during a mean follow-up period of 21.2 months. Three tachyarrhythmia recurrences developed, and there were 4 occurrences of sinus bradycardia. Five of these patients required postoperative pacemaker implantation. The mid-term results of Fontan conversion and arrhythmia surgery in our institute were satisfactory. The occurrence of unexpected postoperative pacemaker requirement was high in the patients who underwent a right atrial or bilateral atrial maze procedure. Pacemaker or lead implantation is recommended for patients planned to undergo a right-side or full maze procedure. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Attraction and repulsion of spiral waves by inhomogeneity of conduction anisotropy--a model of spiral wave interaction with electrical remodeling of heart tissue.

    Science.gov (United States)

    Kuklik, Pawel; Sanders, Prashanthan; Szumowski, Lukasz; Żebrowski, Jan J

    2013-01-01

    Various forms of heart disease are associated with remodeling of the heart muscle, which results in a perturbation of cell-to-cell electrical coupling. These perturbations may alter the trajectory of spiral wave drift in the heart muscle. We investigate the effect of spatially extended inhomogeneity of transverse cell coupling on the spiral wave trajectory using a simple active media model. The spiral wave was either attracted or repelled from the center of inhomogeneity as a function of cell excitability and gradient of the cell coupling. High levels of excitability resulted in an attraction of the wave to the center of inhomogeneity, whereas low levels resulted in an escape and termination of the spiral wave. The spiral wave drift velocity was related to the gradient of the coupling and the initial position of the wave. In a diseased heart, a region of altered transverse coupling corresponds with local gap junction remodeling that may be responsible for stabilization-destabilization of spiral waves and hence reflect potentially important targets in the treatment of heart arrhythmias.

  19. Effects of dexmedetomidine on heart arrhythmia prevention in off-pump coronary artery bypass surgery: A randomized clinical trial.

    Science.gov (United States)

    Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima

    2017-10-01

    Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes

  20. Modeling of pseudoacoustic P-waves in orthorhombic media with a low-rank approximation

    KAUST Repository

    Song, Xiaolei

    2013-06-04

    Wavefield extrapolation in pseudoacoustic orthorhombic anisotropic media suffers from wave-mode coupling and stability limitations in the parameter range. We use the dispersion relation for scalar wave propagation in pseudoacoustic orthorhombic media to model acoustic wavefields. The wavenumber-domain application of the Laplacian operator allows us to propagate the P-waves exclusively, without imposing any conditions on the parameter range of stability. It also allows us to avoid dispersion artifacts commonly associated with evaluating the Laplacian operator in space domain using practical finite-difference stencils. To handle the corresponding space-wavenumber mixed-domain operator, we apply the low-rank approximation approach. Considering the number of parameters necessary to describe orthorhombic anisotropy, the low-rank approach yields space-wavenumber decomposition of the extrapolator operator that is dependent on space location regardless of the parameters, a feature necessary for orthorhombic anisotropy. Numerical experiments that the proposed wavefield extrapolator is accurate and practically free of dispersion. Furthermore, there is no coupling of qSv and qP waves because we use the analytical dispersion solution corresponding to the P-wave.

  1. Associations between arrhythmia episodes and temporally and spatially resolved black carbon and particulate matter in elderly patients

    Science.gov (United States)

    Zanobetti, Antonella; Coull, Brent A.; Gryparis, Alexandros; Kloog, Itai; Sparrow, David; Vokonas, Pantel S; Wright, Robert O.; Gold, Diane R; Schwartz, Joel

    2015-01-01

    Objectives Ambient air pollution has been associated with sudden deaths, some of which are likely due to ventricular arrhythmias. Defibrillator discharge studies have examined the association of air pollution with arrhythmias in sensitive populations. No studies have assessed this association using residence-specific estimates of air pollution exposure. Methods In the Normative Aging Study, we investigated the association between temporally-and spatially-resolved black carbon (BC) and PM2.5 and arrhythmia episodes (bigeminy, trigeminy or couplets episodes) measured as ventricular ectopy (VE) by 4-min electrocardiogram (ECG) monitoring in repeated measures of 701 subjects, during the years 2000 to 2010. We used a binomial distribution (having or not a VE episode) in a mixed effect model with a random intercept for subject, controlling for seasonality, temperature, day of the week, medication use, smoking, having diabetes, BMI and age. We also examined whether these associations were modified by genotype or phenotype. Results We found significant increases in VE with both pollutants and lags; for the estimated concentration averaged over the three days prior to the health assessment we found increases in the odds of having VE with an OR of 1.52 (95% CI: 1.19–1.94) for an IQR (0.30 μg/m3) increase in BC and an OR of 1.39 (95% CI: 1.12–1.71) for an IQR (5.63 μg/m3) increase in PM2.5. We also found higher effects in subjects with the GSTT1 and GSTM1 variants and in obese (P-valuespollutants may increase the risk of ventricular arrhythmia in elderly subjects. PMID:24142987

  2. Prediction of tonic parasympathetic cardiac control using respiratory sinus arrhythmia: the need for respiratory control

    NARCIS (Netherlands)

    GROSSMAN, P.; Karemaker, J.; Wieling, W.

    1991-01-01

    Respiratory sinus arrhythmia (RSA) has received much attention in recent years due to the large body of evidence indicating that variations in this phenomenon represent alterations in parasympathetic cardiac control. Although it appears that respiratory sinus arrhythmia is mediated by vagal

  3. Cardiac arrhythmia detection using combination of heart rate variability analyses and PUCK analysis.

    Science.gov (United States)

    Mahananto, Faizal; Igasaki, Tomohiko; Murayama, Nobuki

    2013-01-01

    This paper presents cardiac arrhythmia detection using the combination of a heart rate variability (HRV) analysis and a "potential of unbalanced complex kinetics" (PUCK) analysis. Detection performance was improved by adding features extracted from the PUCK analysis. Initially, R-R interval data were extracted from the original electrocardiogram (ECG) recordings and were cut into small segments and marked as either normal or arrhythmia. HRV analyses then were conducted using the segmented R-R interval data, including a time-domain analysis, frequency-domain analysis, and nonlinear analysis. In addition to the HRV analysis, PUCK analysis, which has been implemented successfully in a foreign exchange market series to characterize change, was employed. A decision-tree algorithm was applied to all of the obtained features for classification. The proposed method was tested using the MIT-BIH arrhythmia database and had an overall classification accuracy of 91.73%. After combining features obtained from the PUCK analysis, the overall accuracy increased to 92.91%. Therefore, we suggest that the use of a PUCK analysis in conjunction with HRV analysis might improve performance accuracy for the detection of cardiac arrhythmia.

  4. Atrioventricular block, ECG tracing (image)

    Science.gov (United States)

    ... an abnormal rhythm (arrhythmia) called an atrioventricular (AV) block. P waves show that the top of the ... wave (and heart contraction), there is an atrioventricular block, and a very slow pulse (bradycardia).

  5. Numerical simulation of amplification of space charge waves in n-InP films

    International Nuclear Information System (INIS)

    Garcia-Barrientos, Abel; Palankovski, Vassil

    2011-01-01

    The non-linear interaction of space charge waves including the amplification in microwave and millimeter wave range in n-InP films, possessing the negative differential conductance phenomenon, is investigated theoretically. Both the amplified signal and the generation of harmonics of the input signal are demonstrated, which are due to non-linear effect of the negative differential resistance. It is possible to observe an amplification of the space charge waves in n-InP films of submicron thicknesses at essentially higher frequencies f <70 GHz, when compared with n-GaAs films f < 44 GHz. The increment observed in the gain is due to the larger dynamic range in n-InP than in n-GaAs films.

  6. Induced charge electrophoresis of a conducting cylinder in a nonconducting cylindrical pore and its micromotoring application

    Science.gov (United States)

    Feng, Huicheng; Wong, Teck Neng; Che, Zhizhao

    2016-08-01

    Induced charge electrophoresis of a conducting cylinder suspended in a nonconducting cylindrical pore is theoretically analyzed and a micromotor is proposed that utilizes the cylinder rotation. The cylinder velocities are analytically obtained in the Dirichlet and the Neumann boundary conditions of the electric field on the cylindrical pore. The results show that the cylinder not only translates but also rotates when it is eccentric with respect to the cylindrical pore. The influences of a number of parameters on the cylinder velocities are characterized in detail. The cylinder trajectories show that the cylinder approaches and becomes stationary at certain positions within the cylindrical pore. The proposed micromotor is capable of working under a heavy load with a high rotational velocity when the eccentricity is large and the applied electric field is strong.

  7. Dipyridamole-thallium tests are predictive of severe cardiac arrhythmias in patients with left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Saragoca, M.A.; Canziani, M.E.; Gil, M.A.; Castiglioni, M.L.; Cassiolato, J.L.; Barbieri, A.; Lima, V.C.; Draibe, S.A.; Martinez, E.E.

    1991-01-01

    In a population of patients with chronic renal failure (CRF) and a high prevalence of left ventricular hypertrophy (LVH) undergoing chronic hemodialysis, the authors investigated the association between the results of dipyridamole-thallium tests (DTTs) and the occurrence of ventricular arrhythmias. They observed a positive significant association between positive DTTs and the occurrence of severe forms of ventricular arrhythmias. A significant association was also observed between the presence of severe LVH and the occurrence of severe ventricular arrhythmias. However, no association was found between the presence of LVH and the positivity of the DTT. As most of their patients with positive DTTs had unimpaired coronary circulations, they conclude that positive DTTs, although falsely indicative of impaired myocardial blood supply, does have an important clinical relevance, indicating increased risk of morbidity (and, possibly, mortality) due to ventricular arrhythmias in a population of CRF patients submitted to chronic renal function replacement program

  8. A comparison of heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major.

    Science.gov (United States)

    Amoozgar, Hamid; Zeighami, Samaneh; Haghpanah, Sezaneh; Karimi, Mehran

    2017-01-01

    The goal of this study was to compare heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major. In this cross-sectional study, 60 patients with beta thalassemia major and 60 patients with beta thalassemia intermedia who had clinically no symptoms of arrhythmia and clinically normal heart function were evaluated using 24-hour ambulatory electrocardiogram monitoring and echocardiography. For data analysis SPSS ver.20 software was used. A P-value of less than 0.05 was considered statistically significant. The mean age of the beta thalassemia intermedia patients was 24.18 ± 7.9 years and the mean age in beta thalassemia major was 24.38 ± 7.7 years (P>0.05). Premature atrial contractions (PACs) were observed in 14 (23.3%) patients with beta thalassemia intermedia and in 22 (36.6%) beta thalassemia major patients. Premature ventricular contractions (PVCs) were detected in 8 (13.3%) patients in the beta thalassemia intermediate group and 16 (26.6) patients in the beta thalassemia major group, respectively. The left ventricular diastolic dimension, end-diastolic volume, and stroke volume were significantly higher in beta thalassemia intermedia group (Pintermedia group. Both atrial and ventricular arrhythmias were more common in the beta thalassemia major group. Higher end-diastolic volume and stroke volume were detected in the beta thalassemia intermedia group. Pulmonary acceleration time was lower in the beta thalassemia intermedia group, which can be an indicator of higher pulmonary pressure.

  9. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    Science.gov (United States)

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support

  10. Electrocardiographic changes during induced therapeutic hypothermia in comatose survivors after cardiac arrest

    Institute of Scientific and Technical Information of China (English)

    Pablo; Salinas; Esteban; Lopez-de-Sa; Laura; Pena-Conde; Ana; Viana-Tejedor; Juan; Ramon; Rey-Blas; Eduardo; Armada; Jose; Luis; Lopez-Sendon

    2015-01-01

    AIM: To assess the safety of therapeutic hypothermia(TH) concerning arrhythmias we analyzed serial electrocardiograms(ECG) during TH.METHODS: All patients recovered from a cardiac arrest with Glasgow < 9 at admission were treated with induced mild TH to 32-34℃. TH was obtained with cool fluid infusion or a specific intravascular device. Twelvelead ECG before,during,and after TH,as well as ECG telemetry data was recorded in all patients. From a total of 54 patients admitted with cardiac arrest during the study period,47 patients had the 3 ECG and telemetry data available. ECG analysis was blinded and performed with manual caliper by two independent cardiologists from blinded copies of original ECG,recorded at 25 mm/s and 10 mm/m V. Coronary care unit staff analyzed ECG telemetry for rhythm disturbances. Variables measured in ECG were rhythm,RR,PR,QT and corrected QT(QTc by Bazett formula,measured in lead v2) intervals,QRS duration,presence of Osborn’s J wave and U wave,as well as ST segment displacement and T wave amplitude in leads Ⅱ,v2 and v5.RESULTS: Heart rate went down an average of 19 bpm during hypothermia and increased again 16 bpm with rewarming(P < 0.0005,both). There was a nonsignificant prolongation of the PR interval during TH and a significant decrease with rewarming(P = 0.041). QRS duration significantly prolonged(P = 0.041) with TH and shortened back(P < 0.005) with rewarming. QTc interval presented a mean prolongation of 58 ms(P < 0.005) during TH and a significant shortening with rewarming of 22.2 ms(P = 0.017). Osborn or J wave was found in 21.3% of the patients. New arrhythmias occurred in 38.3% of the patients. Most frequent arrhythmia was non-sustained ventricular tachycardia(19.1%),followed by severe bradycardia or paced rhythm(10.6%),accelerated nodal rhythm(8.5%) and atrial fibrillation(6.4%). No life threatening arrhythmias(sustained ventricular tachycardia,polymorphic ventricular tachycardia or ventricular fibrillation) occurred

  11. Ischaemic stroke in hyperthyroidism without cardiac arrhythmia - A ...

    African Journals Online (AJOL)

    BACKGROUND: The relationship between hyperthyroidism and stroke is well established in the setting of atrial fibrillation. However there is limited literature for ischaemic stroke occurring in hyperthyroidism without cardiac arrhythmia. No such case had been described in South East Nigeria. METHOD: This report highlights ...

  12. Detection of Life Threatening Ventricular Arrhythmia Using Digital Taylor Fourier Transform.

    Science.gov (United States)

    Tripathy, Rajesh K; Zamora-Mendez, Alejandro; de la O Serna, José A; Paternina, Mario R Arrieta; Arrieta, Juan G; Naik, Ganesh R

    2018-01-01

    Accurate detection and classification of life-threatening ventricular arrhythmia episodes such as ventricular fibrillation (VF) and rapid ventricular tachycardia (VT) from electrocardiogram (ECG) is a challenging problem for patient monitoring and defibrillation therapy. This paper introduces a novel method for detection and classification of life-threatening ventricular arrhythmia episodes. The ECG signal is decomposed into various oscillatory modes using digital Taylor-Fourier transform (DTFT). The magnitude feature and a novel phase feature namely the phase difference (PD) are evaluated from the mode Taylor-Fourier coefficients of ECG signal. The least square support vector machine (LS-SVM) classifier with linear and radial basis function (RBF) kernels is employed for detection and classification of VT vs. VF, non-shock vs. shock and VF vs. non-VF arrhythmia episodes. The accuracy, sensitivity, and specificity values obtained using the proposed method are 89.81, 86.38, and 93.97%, respectively for the classification of Non-VF and VF episodes. Comparison with the performance of the state-of-the-art features demonstrate the advantages of the proposition.

  13. Loperamide Induced Life Threatening Ventricular Arrhythmia

    Directory of Open Access Journals (Sweden)

    Ankit Upadhyay

    2016-01-01

    Full Text Available Loperamide is over-the-counter antidiarrheal agent acting on peripherally located μ opioid receptors. It is gaining popularity among drug abusers as opioid substitute. We report a case of a 46-year-old male that was presented after cardiac arrest. After ruling out ischemia, cardiomyopathy, pulmonary embolism, central nervous system pathology, sepsis, and other drug toxicity, we found out that patient was using around 100 mg of Loperamide to control his chronic diarrhea presumably because of irritable bowel syndrome for last five years and consumed up to 200 mg of Loperamide daily for last two days before the cardiac arrest. We hypothesize that the patient’s QTc prolongation and subsequent cardiac arrest are due to Loperamide toxicity. Patient experienced gradual resolution of tachyarrhythmia and gradual decrease in QTc interval during hospitalization which supports the evidence of causal relationship between Loperamide overdose and potentially fatal arrhythmias. It also provided the clue that patient may have congenital long QT syndrome which was unmasked by Loperamide causing ventricular arrhythmias. This case adds one more pearl in the literature to support that Loperamide overdose related cardiac toxicity does exist and it raises concerns over Loperamide abuse in the community.

  14. Fractal ventilation enhances respiratory sinus arrhythmia

    Directory of Open Access Journals (Sweden)

    Girling Linda G

    2005-05-01

    Full Text Available Abstract Background Programming a mechanical ventilator with a biologically variable or fractal breathing pattern (an example of 1/f noise improves gas exchange and respiratory mechanics. Here we show that fractal ventilation increases respiratory sinus arrhythmia (RSA – a mechanism known to improve ventilation/perfusion matching. Methods Pigs were anaesthetised with propofol/ketamine, paralysed with doxacurium, and ventilated in either control mode (CV or in fractal mode (FV at baseline and then following infusion of oleic acid to result in lung injury. Results Mean RSA and mean positive RSA were nearly double with FV, both at baseline and following oleic acid. At baseline, mean RSA = 18.6 msec with CV and 36.8 msec with FV (n = 10; p = 0.043; post oleic acid, mean RSA = 11.1 msec with CV and 21.8 msec with FV (n = 9, p = 0.028; at baseline, mean positive RSA = 20.8 msec with CV and 38.1 msec with FV (p = 0.047; post oleic acid, mean positive RSA = 13.2 msec with CV and 24.4 msec with FV (p = 0.026. Heart rate variability was also greater with FV. At baseline the coefficient of variation for heart rate was 2.2% during CV and 4.0% during FV. Following oleic acid the variation was 2.1 vs. 5.6% respectively. Conclusion These findings suggest FV enhances physiological entrainment between respiratory, brain stem and cardiac nonlinear oscillators, further supporting the concept that RSA itself reflects cardiorespiratory interaction. In addition, these results provide another mechanism whereby FV may be superior to conventional CV.

  15. Statins as anti-arrhythmics: a systematic review part II: effects on risk of ventricular arrhythmias.

    Science.gov (United States)

    Abuissa, Hussam; O'Keefe, James H; Bybee, Kevin A

    2009-10-01

    Recent studies have demonstrated that statins may possess anti-arrhythmic properties in addition to their lipid-lowering effects. Studies which reported the association of statins with the incidence of ventricular arrhythmias were identified through a systematic review of the published literature. Statins have been associated with a significant reductions in ventricular arrhythmia in cardiomyopathy patients with an implantable cardioverter defibrillator, although randomized trials have not been completed. Published data suggests that statins may possess anti-arrhythmic properties that reduce the propensity for ventricular arrhythmias. Most of this data is observational; more randomized, placebo-controlled trials are needed.

  16. Conventional versus 3-D Echocardiography to Predict Arrhythmia Recurrence After Atrial Fibrillation Ablation.

    Science.gov (United States)

    Bossard, Matthias; Knecht, Sven; Aeschbacher, Stefanie; Buechel, Ronny R; Hochgruber, Thomas; Zimmermann, Andreas J; Kessel-Schaefer, Arnheid; Stephan, Frank-Peter; Völlmin, Gian; Pradella, Maurice; Sticherling, Christian; Osswald, Stefan; Kaufmann, Beat A; Conen, David; Kühne, Michael

    2017-06-01

    Arrhythmia recurrence after atrial fibrillation (AF) ablation remains high and requires repeat interventions in a substantial number of patients. We assessed the value of conventional and 3-D echocardiography to predict AF recurrence. Consecutive patients undergoing AF ablation by means of pulmonary vein isolation were included in a prospective registry. Echocardiograms were obtained prior to the ablation procedure, and analyzed offline in a standardized manner, including 3-D left atrial (LA) volumetry and determination of LA function and sphericity. The primary endpoint, AF recurrence (>30 seconds) between 3 to 12 months after AF ablation, was independently adjudicated. We included 276 patients (73% male, mean age 59.9 ± 9.9 years). Paroxysmal and persistent AF were present in 178 (64%) and 98 (36%) patients, respectively. Mean left ventricular ejection fraction and indexed LA volume in 3-D (LAVI) were 52 ± 12% and 42 ± 13 mL/m 2 , respectively. AF recurrence was observed in 110 (40%) patients after a single procedure. Median (interquartile range) time to AF recurrence was 123 (92; 236) days. In multivariable Cox regression models, the only predictors for AF recurrence were the minimal, maximal, and indexed 3-D LA volumes, P = 0.024, P = 0.016, and P = 0.014, respectively. Quartile specific analysis of 3-D LAVI showed an HR of 1.885 (95%CI 1.066-3.334; P for trend = 0.015) for the highest compared to the lowest quartile. Our results show the important role of LA volume for the long-term freedom from arrhythmia after AF ablation. These data also highlight the potential of 3-D echocardiography in this context and may facilitate patient selection for AF ablation. © 2017 Wiley Periodicals, Inc.

  17. Double hazards of ischemia and reperfusion arrhythmias in a patient with variant angina pectoris.

    Science.gov (United States)

    Xu, Mingzhu; Yang, Xiangjun

    2015-01-01

    Variant angina pectoris, also called Prinzmetal's angina, is a syndrome caused by vasospasms of the coronary arteries. It can lead to myocardial infarction, ventricular arrhythmias, atrioventricular block and even sudden cardiac death. We report the case of a 53 year-old male patient with recurrent episodes of chest pain and arrhythmias in the course of related variant angina pectoris. It is likely that the reperfusion following myocardial ischemia was responsible for the ventricular fibrillation while the ST-segment returned to the baseline. This case showed that potential lethal arrhythmias could arise due to variant angina pectoris. It also indicated that ventricular fibrillation could be self-terminated. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A novel NaV1.5 voltage sensor mutation associated with severe atrial and ventricular arrhythmias.

    Science.gov (United States)

    Wang, Hong-Gang; Zhu, Wandi; Kanter, Ronald J; Silva, Jonathan R; Honeywell, Christina; Gow, Robert M; Pitt, Geoffrey S

    2016-03-01

    Inherited autosomal dominant mutations in cardiac sodium channels (NaV1.5) cause various arrhythmias, such as long QT syndrome and Brugada syndrome. Although dozens of mutations throughout the protein have been reported, there are few reported mutations within a voltage sensor S4 transmembrane segment and few that are homozygous. Here we report analysis of a novel lidocaine-sensitive recessive mutation, p.R1309H, in the NaV1.5 DIII/S4 voltage sensor in a patient with a complex arrhythmia syndrome. We expressed the wild type or mutant NaV1.5 heterologously for analysis with the patch-clamp and voltage clamp fluorometry (VCF) techniques. p.R1309H depolarized the voltage-dependence of activation, hyperpolarized the voltage-dependence of inactivation, and slowed recovery from inactivation, thereby reducing the channel availability at physiologic membrane potentials. Additionally, p.R1309H increased the "late" Na(+) current. The location of the mutation in DIIIS4 prompted testing for a gating pore current. We observed an inward current at hyperpolarizing voltages that likely exacerbates the loss-of-function defects at resting membrane potentials. Lidocaine reduced the gating pore current. The p.R1309H homozygous NaV1.5 mutation conferred both gain-of-function and loss-of-function effects on NaV1.5 channel activity. Reduction of a mutation-induced gating pore current by lidocaine suggested a therapeutic mechanism. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Oxidized CaMKII (Ca2+/Calmodulin-Dependent Protein Kinase II) Is Essential for Ventricular Arrhythmia in a Mouse Model of Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Wang, Qiongling; Quick, Ann P; Cao, Shuyi; Reynolds, Julia; Chiang, David Y; Beavers, David; Li, Na; Wang, Guoliang; Rodney, George G; Anderson, Mark E; Wehrens, Xander H T

    2018-04-01

    Duchenne muscular dystrophy patients are prone to ventricular arrhythmias, which may be caused by abnormal calcium (Ca 2+ ) homeostasis and elevated reactive oxygen species. CaMKII (Ca 2+ /calmodulin-dependent protein kinase II) is vital for normal Ca 2+ homeostasis, but excessive CaMKII activity contributes to abnormal Ca 2+ homeostasis and arrhythmias in cardiomyocytes. Reactive oxygen species induce CaMKII to become autonomously active. We hypothesized that genetic inhibition of CaMKII oxidation (ox-CaMKII) in a mouse model of Duchenne muscular dystrophy can alleviate abnormal Ca 2+ homeostasis, thus, preventing ventricular arrhythmia. The objective of this study was to test if selective loss of ox-CaMKII affects ventricular arrhythmias in the mdx mouse model of Duchenne muscular dystrophy. 5-(6)-Chloromethyl-2,7-dichlorodihydrofluorescein diacetate staining revealed increased reactive oxygen species production in ventricular myocytes isolated from mdx mice, which coincides with elevated ventricular ox-CaMKII demonstrated by Western blotting. Genetic inhibition of ox-CaMKII by knockin replacement of the regulatory domain methionines with valines (MM-VV [CaMKII M281/282V]) prevented ventricular tachycardia in mdx mice. Confocal calcium imaging of ventricular myocytes isolated from mdx :MM-VV mice revealed normalization of intracellular Ca 2+ release events compared with cardiomyocytes from mdx mice. Abnormal action potentials assessed by optical mapping in mdx mice were also alleviated by genetic inhibition of ox-CaMKII. Knockout of the NADPH oxidase regulatory subunit p47 phox normalized elevated ox-CaMKII, repaired intracellular Ca 2+ homeostasis, and rescued inducible ventricular arrhythmias in mdx mice. Inhibition of reactive oxygen species or ox-CaMKII protects against proarrhythmic intracellular Ca 2+ handling and prevents ventricular arrhythmia in a mouse model of Duchenne muscular dystrophy. © 2018 American Heart Association, Inc.

  20. Inflammation markers are associated with metabolic syndrome and ventricular arrhythmia in patients with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Krzysztof Safranow

    2016-02-01

    Full Text Available Background: Inflammation plays a major role in the development and progression of atherosclerosis and coronary artery disease (CAD. Inflammation markers, including white blood cell (WBC count, C-reactive protein (CRP and interleukin-6 (IL-6, are widely used for cardiovascular risk prediction. The aim of the study was to establish factors associated with WBC, CRP and IL-6 in patients with CAD. Two functional polymorphisms in genes encoding enzymes participating in adenosine metabolism were analyzed (C34T AMPD1, G22A ADA. Methods: Plasma concentrations of IL-6 were measured using high-sensitivity ELISA kits, and the nephelometric method was used for high-sensitivity CRP (hs-CRP measurement in 167 CAD patients. Results: Presence of metabolic syndrome (MS and its components, presence of heart failure, severity of CAD symptoms, severe past ventricular arrhythmia (sustained ventricular tachycardia [sVT] or ventricular fibrillation [VF], lower left ventricle ejection fraction, higher left ventricle mass index, higher end-diastolic volume and higher number of smoking pack-years were significantly associated with higher WBC, CRP and IL-6. Strong associations with arrhythmia were observed for IL-6 (median 3.90 vs 1.89 pg/mL, p<0.00001 and CRP concentration (6.32 vs 1.47 mg/L, p=0.00009, while MS was associated most strongly with IL-6. CRP and IL-6 were independent markers discriminating patients with sVT or VF. There were no associations between AMPD1 or ADA genotypes and inflammation markers. Conclusions: WBC, CRP and IL-6 are strongly associated with components of the metabolic syndrome. Their strong association with life-threatening ventricular arrhythmia emphasizes the proarrhythmic role of inflammation in the increased cardiovascular risk of CAD patients.

  1. Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2015-01-01

    We present a novel algorithm for classifying true and false alarms of five life-threatening arrhythmias in intensive care. This algorithm was entered in the PhysioNet/Computing in Cardiology Challenge 2015 Reducing False Arrhythmia Alarms in the ICU. The algorithm performs a binary classification of

  2. Risk prediction of ventricular arrhythmias and myocardial function in Lamin A/C mutation positive subjects

    DEFF Research Database (Denmark)

    Hasselberg, Nina E; Edvardsen, Thor; Petri, Helle

    2014-01-01

    Mutations in the Lamin A/C gene may cause atrioventricular block, supraventricular arrhythmias, ventricular arrhythmias (VA), and dilated cardiomyopathy. We aimed to explore the predictors and the mechanisms of VA in Lamin A/C mutation-positive subjects.METHODS AND RESULTS: We included 41 Lamin A/C...

  3. Features of Chaotic Transients in Excitable Media Governed by Spiral and Scroll Waves

    Science.gov (United States)

    Lilienkamp, Thomas; Christoph, Jan; Parlitz, Ulrich

    2017-08-01

    In excitable media, chaotic dynamics governed by spiral or scroll waves is often not persistent but transient. Using extensive simulations employing different mathematical models we identify a specific type-II supertransient by an exponential increase of transient lifetimes with the system size in 2D and an investigation of the dynamics (number and lifetime of spiral waves, Kaplan-Yorke dimension). In 3D, simulations exhibit an increase of transient lifetimes and filament lengths only above a critical thickness. Finally, potential implications for understanding cardiac arrhythmias are discussed.

  4. Automated testing of arrhythmia monitors using annotated databases.

    Science.gov (United States)

    Elghazzawi, Z; Murray, W; Porter, M; Ezekiel, E; Goodall, M; Staats, S; Geheb, F

    1992-01-01

    Arrhythmia-algorithm performance is typically tested using the AHA and MIT/BIH databases. The tools for this test are simulation software programs. While these simulations provide rapid results, they neglect hardware and software effects in the monitor. To provide a more accurate measure of performance in the actual monitor, a system has been developed for automated arrhythmia testing. The testing system incorporates an IBM-compatible personal computer, a digital-to-analog converter, an RS232 board, a patient-simulator interface to the monitor, and a multi-tasking software package for data conversion and communication with the monitor. This system "plays" patient data files into the monitor and saves beat classifications in detection files. Tests were performed using the MIT/BIH and AHA databases. Statistics were generated by comparing the detection files with the annotation files. These statistics were marginally different from those that resulted from the simulation. Differences were then examined. As expected, the differences were related to monitor hardware effects.

  5. [Clinical aspects of reperfusion arrhythmia following intravenous thrombolysis in acute myocardial infarct].

    Science.gov (United States)

    Kettner, W; Klein, E; Schulz, W; Götze, C

    1987-05-15

    In accordance with the majority of the reports in the literature reperfusion arrhythmias were observed in more than 30% of the patients with acute myocardial infarction (n = 25) under or immediately after a highly dosed short-term infusion with streptokinase. With reference to indirect signs the recanalisation rate was assumed with 75%. Only one third of the reperfusion arrhythmias had haemodynamically significant characteristics and required an influence. Though in literature from animal experimental findings directive conclusions for the therapy are to be derived, the procedure in practice is still vastly empirical. In the ventricular tachycardia lidocaine, procainamide and ajmalin may be recommended. In ineffectiveness or particularly threatening situations the electrotherapy (cardioversion, DC-shock) is to be preferred. The concept inaugurated by Corr and Witkowski apply alpha-adrenoreceptor blockers has not yet entered the clinical practice. Possible problems in the treatment of reperfusion arrhythmias in the prehospital phase should at present still be a reason not to antedate the thrombolytic therapy into this phase.

  6. Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.

    Science.gov (United States)

    Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe

    2014-01-01

    As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.

  7. Determination of elastic anisotropy of rocks from P- and S-wave velocities: numerical modelling and lab measurements

    Science.gov (United States)

    Svitek, Tomáš; Vavryčuk, Václav; Lokajíček, Tomáš; Petružálek, Matěj

    2014-12-01

    The most common type of waves used for probing anisotropy of rocks in laboratory is the direct P wave. Information potential of the measured P-wave velocity, however, is limited. In rocks displaying weak triclinic anisotropy, the P-wave velocity depends just on 15 linear combinations of 21 elastic parameters, called the weak-anisotropy parameters. In strong triclinic anisotropy, the P-wave velocity depends on the whole set of 21 elastic parameters, but inversion for six of them is ill-conditioned and these parameters are retrieved with a low accuracy. Therefore, in order to retrieve the complete elastic tensor accurately, velocities of S waves must also be measured and inverted. For this purpose, we developed a lab facility which allows the P- and S-wave ultrasonic sounding of spherical rock samples in 132 directions distributed regularly over the sphere. The velocities are measured using a pair of P-wave sensors with the transmitter and receiver polarized along the radial direction and using two pairs of S-wave sensors with the transmitter and receiver polarized tangentially to the spherical sample in mutually perpendicular directions. We present inversion methods of phase and ray velocities for elastic parameters describing general triclinic anisotropy. We demonstrate on synthetic tests that the inversion becomes more robust and stable if the S-wave velocities are included. This applies even to the case when the velocity of the S waves is measured in a limited number of directions and with a significantly lower accuracy than that of the P wave. Finally, we analyse velocities measured on a rock sample from the Outokumpu deep drill hole, Finland. We present complete sets of elastic parameters of the sample including the error analysis for several levels of confining pressure ranging from 0.1 to 70 MPa.

  8. Underwater Shock Wave Research Applied to Therapeutic Device Developments

    Science.gov (United States)

    Takayama, K.; Yamamoto, H.; Shimokawa, H.

    2013-07-01

    The chronological development of underwater shock wave research performed at the Shock Wave Research Center of the Institute of Fluid Science at the Tohoku University is presented. Firstly, the generation of planar underwater shock waves in shock tubes and their visualization by using the conventional shadowgraph and schlieren methods are described. Secondly, the generation of spherical underwater shock waves by exploding lead azide pellets weighing from several tens of micrograms to 100 mg, that were ignited by irradiating with a Q-switched laser beam, and their visualization by using double exposure holographic interferometry are presented. The initiation, propagation, reflection, focusing of underwater shock waves, and their interaction with various interfaces, in particular, with air bubbles, are visualized quantitatively. Based on such a fundamental underwater shock wave research, collaboration with the School of Medicine at the Tohoku University was started for developing a shock wave assisted therapeutic device, which was named an extracorporeal shock wave lithotripter (ESWL). Miniature shock waves created by irradiation with Q-switched HO:YAG laser beams are studied, as applied to damaged dysfunctional nerve cells in the myocardium in a precisely controlled manner, and are effectively used to design a catheter for treating arrhythmia.

  9. Magnetic manipulation of topological states in p-wave superconductors

    DEFF Research Database (Denmark)

    Mercaldo, Maria Teresa; Cuoco, Mario; Kotetes, Panagiotis

    2018-01-01

    Substantial experimental investigation has provided evidence for spin-triplet pairing in diverse classes of materials and in a variety of artificial heterostructures. One of the fundamental challenges in this framework is how to manipulate the topological behavior of p-wave superconductors (PSC...

  10. Automatic picking of direct P, S seismic phases and fault zone head waves

    Science.gov (United States)

    Ross, Z. E.; Ben-Zion, Y.

    2014-10-01

    We develop a set of algorithms for automatic detection and picking of direct P and S waves, as well as fault zone head waves (FZHW), generated by earthquakes on faults that separate different lithologies and recorded by local seismic networks. The S-wave picks are performed using polarization analysis and related filters to remove P-wave energy from the seismograms, and utilize STA/LTA and kurtosis detectors in tandem to lock on the phase arrival. The early portions of P waveforms are processed with STA/LTA, kurtosis and skewness detectors for possible first-arriving FZHW. Identification and picking of direct P and FZHW is performed by a multistage algorithm that accounts for basic characteristics (motion polarities, time difference, sharpness and amplitudes) of the two phases. The algorithm is shown to perform well on synthetic seismograms produced by a model with a velocity contrast across the fault, and observed data generated by earthquakes along the Parkfield section of the San Andreas fault and the Hayward fault. The developed techniques can be used for systematic processing of large seismic waveform data sets recorded near major faults.

  11. Development of a Novel Shock Wave Catheter Ablation System

    Science.gov (United States)

    Yamamoto, H.; Hasebe, Yuhi; Kondo, Masateru; Fukuda, Koji; Takayama, Kazuyoshi; Shimokawa, Hiroaki

    Although radio-frequency catheter ablation (RFCA) is quite effective for the treatment tachyarrhythmias, it possesses two fundamental limitations, including limited efficacy for the treatment of ventricular tachyarrhythmias of epicardial origin and the risk of thromboembolism. Consequently, new method is required, which can eradicate arrhythmia source in deep part of cardiac muscle without heating. On the other hand, for a medical application of shock waves, extracorporeal shock wave lithotripter (ESWL) has been established [1]. It was demonstrated that the underwater shock focusing is one of most efficient method to generate a controlled high pressure in a small region [2]. In order to overcome limitations of existing methods, we aimed to develop a new catheter ablation system with underwater shock waves that can treat myocardium at arbitrary depth without causing heat.

  12. Life threatening arrhythmias: Knowledge and skills among nurses ...

    African Journals Online (AJOL)

    Conclusion: Although the majority of the participants scored highly in their level of knowledge regarding life threatening arrhythmias, they scored poorly in most of the observed skills when identifying and treating this patient group. It is important that hospital administration take into consideration the identified areas of ...

  13. Life threatening arrhythmias: Knowledge and skills among nurses ...

    African Journals Online (AJOL)

    User

    this study was to assess knowledge and skills of nurses in identifying life ... Much of the literature considers ventricular tachycardia, ventricular fibrillation, ... In critical care settings, bedside nurses play a critical role in arrhythmia identification and ..... Lambert, V.A. & Lambert, C.E. (2008) Nurses' workplace stressors and ...

  14. Intracoronary infusion of catecholamines causes focal arrhythmias in pigs.

    Science.gov (United States)

    Doppalapudi, Harish; Jin, Qi; Dosdall, Derek J; Qin, Hao; Walcott, Gregory P; Killingsworth, Cheryl R; Smith, William M; Ideker, Raymond E; Huang, Jian

    2008-09-01

    Acute ischemia causes myriad changes including increased catecholamines. We tested the hypothesis that elevated catecholamines alone are arrhythmogenic. A 504 electrode sock was placed over both ventricles in six open-chest pigs. During control infusion of saline through a catheter in the left anterior descending coronary artery (LAD), no sustained arrhythmias occurred, and the refractory period estimated by the activation recovery interval (ARI) was 175 +/- 14 ms in the LAD bed below the catheter. After infusion of isoproterenol at 0.1 microg/kg/min through the catheter, the ARI in this bed was significantly reduced to 109 +/- 10 ms. A sharp gradient of refractoriness of 43 +/- 10 ms was at the border of the perfused bed. Sustained monomorphic ventricular tachycardia occurred after drug infusion in the perfused bed or near its boundary in all animals with a cycle length of 329 +/- 26 ms and a focal origin. The maximum slope of the ARI restitution curve at the focal origins of the tachyarrhythmias was always <1 (0.62 +/- 0.15). Similar results with a focal arrhythmia origin occurred in two additional pigs in which intramural mapping was performed with 36 plunge needle electrodes in the left ventricular perfused bed. Regional elevation of a catecholamine, which is one of the alterations produced by acute ischemia, can by itself cause tachyarrhythmias. These arrhythmias are closely associated with a shortened refractory period and a large gradient of the spatial distribution of refractoriness but not with a steep restitution curve.

  15. Constraining P-wave velocity variations in the upper mantle beneath Southeast Asia

    NARCIS (Netherlands)

    Li, Chang; Hilst, R.D. van der; Toksöz, M. Nafi

    2006-01-01

    We have produced a P-wave model of the upper mantle beneath Southeast (SE) Asia from reprocessed short period International Seismological Centre (ISC) P and pP data, short period P data of the Annual Bulletin of Chinese Earthquakes (ABCE), and long period PP-P data.We used 3D sensitivity kernels

  16. Significant correlation of P-wave parameters with left atrial volume index and left ventricular diastolic function.

    Science.gov (United States)

    Tsai, Wei-Chung; Lee, Kun-Tai; Wu, Ming-Tsang; Chu, Chih-Sheng; Lin, Tsung-Hsien; Hsu, Po-Chao; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2013-07-01

    The 12-lead electrocardiogram (ECG) is a commonly used tool to access left atrial enlargement, which is a marker of left ventricular diastolic dysfunction (LVDD). The aim of this study was to evaluate any association of the P-wave measurements in ECG with left atrial volume (LAV) index and LVDD. This study enrolled 270 patients. In this study, 4 ECG P-wave parameters corrected by heart rate, that is, corrected P-wave maximum duration (PWdurMaxC), corrected P-wave dispersion (PWdisperC), corrected P-wave area (PWareaC) and corrected mean P-wave duration (meanPWdurC), were measured. LAV and left ventricular diastolic parameters were measured from echocardiography. LVDD was defined as a pseudonormal or restrictive mitral inflow pattern. The 4 P-wave parameters were significantly correlated with the LAV index after adjusting for age, sex, diabetes, hypertension, coronary artery disease, body mass index and diastolic blood pressure in multivariate analysis. The standardized β coefficients of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 0.338, 0.298, 0.215 and 0.296, respectively. The 4 P-wave parameters were also significantly correlated with LVDD after multivariate logistic regression analysis. The odds ratios (95% confidence intervals) of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 1.03 (1.01-1.04), 1.02 (1.04-1.04), 1.04 (1.02-1.07) and 1.01 (1.00-1.02), respectively. This study demonstrated that PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were important determinants of the LAV index and LVDD. Therefore, screening patients by means of the 12-lead ECG may be helpful in identifying a high-risk group of increased LAV index and LVDD.

  17. Genetic determinants of P wave duration and PR segment

    NARCIS (Netherlands)

    Verweij, Niek; Mateo Leach, Irene; van den Boogaard, Malou; van Veldhuisen, Dirk J.; Christoffels, Vincent M.; Hillege, Hans L.; van Gilst, Wiek H.; Barnett, Phil; de Boer, Rudolf A.; van der Harst, Pim

    2014-01-01

    The PR interval on the ECG reflects atrial depolarization and atrioventricular nodal delay which can be partially differentiated by P wave duration and PR segment, respectively. Genome-wide association studies have identified several genetic loci for PR interval, but it remains to be determined

  18. Genetic Determinants of P Wave Duration and PR Segment

    NARCIS (Netherlands)

    Verweij, Niek; Mateo Leach, Irene; van den Boogaard, Malou; van Veldhuisen, Dirk J.; Christoffels, Vincent M.; Hillege, Hans L.; van Gilst, Wiek H.; Barnett, Phil; de Boer, Rudolf A.; van der Harst, Pim

    Background-The PR interval on the ECG reflects atrial depolarization and atrioventricular nodal delay which can be partially differentiated by P wave duration and PR segment, respectively. Genome-wide association studies have identified several genetic loci for PR interval, but it remains to be

  19. Nonpharmacologic control of postoperative supraventricular arrhythmias using AV nodal fat pad stimulation in a young animal open heart surgical model.

    Science.gov (United States)

    Moak, Jeffrey P; Mercader, Marco A; He, Dingchao; Trachiotis, Gregory; Langert, Joshua; Blicharz, Andy; Montaque, Erin; Li, Xiyan; Cheng, Yao I; McCarter, Robert; Bornzin, Gene A; Martin, Gerard R; Jonas, Richard A

    2013-06-01

    Supraventricular arrhythmias (junctional ectopic tachycardia [JET] and atrial tachyarrhythmias) frequently complicate recovery from open heart surgery in children and can be difficult to manage. Medical treatment of JET can result in significant morbidity. Our goal was to develop a nonpharmacological approach using autonomic stimulation of selective fat pad (FP) regions of the heart in a young canine model of open heart surgery to control 2 common postoperative supraventricular arrhythmias. Eight mongrel dogs, varying in age from 5 to 8 months and weighting 22±4 kg, underwent open heart surgery replicating a nontransannular approach to tetralogy of Fallot repair. Neural stimulation of the right inferior FP was used to control the ventricular response to supraventricular arrhythmias. Right inferior FP stimulation decreased baseline AV nodal conduction without altering sinus cycle length. AV node Wenckebach cycle length prolonged from 270±33 to 352±89 ms, P=0.02. Atrial fibrillation occurred in 7 animals, simulating a rapid atrial tachyarrhythmias. FP stimulation slowed the ventricular response rate from 166±58 to 63±29 beats per minute, Popen heart surgery model. FP stimulation may be a useful new technique for managing children with JET and atrial tachyarrhythmias.

  20. Evaluation of heart rhythm variability and arrhythmia in children with systemic and localized scleroderma.

    Science.gov (United States)

    Wozniak, Jacek; Dabrowski, Rafal; Luczak, Dariusz; Kwiatkowska, Malgorzata; Musiej-Nowakowska, Elzbieta; Kowalik, Ilona; Szwed, Hanna

    2009-01-01

    To evaluate possible disturbances in autonomic regulation and cardiac arrhythmias in children with localized and systemic scleroderma. There were 40 children included in the study: 20 with systemic and 20 with localized scleroderma. The control group comprised 20 healthy children. In 24-hour Holter recording, the average rate of sinus rhythm was significantly higher in the groups with systemic and localized scleroderma than in the control group, but there was no significant difference between them. The variability of heart rhythm in both groups was significantly decreased. In the group with systemic scleroderma, single supraventricular ectopic beats were observed in 20% and runs were seen in 40% of patients. In the group with localized scleroderma, supraventricular single ectopic beats occurred in 35% of patients and runs in 45% of those studied. Ventricular arrhythmia occurred in 2 children with systemic scleroderma, but in 1 child, it was complex. The most frequent cardiac arrhythmias in both types of scleroderma in children were of supraventricular origin, whereas ventricular arrhythmias did not occur very often. There were no significant differences in autonomic disturbances manifesting as a higher heart rate and decreased heart rate variability between localized and systemic scleroderma.

  1. Developmental trajectories of respiratory sinus arrhythmia and preejection period in middle childhood.

    Science.gov (United States)

    Hinnant, J Benjamin; Elmore-Staton, Lori; El-Sheikh, Mona

    2011-01-01

    Autonomic nervous system (ANS) activity has been linked repeatedly to children's socioemotional and behavioral adaptive functioning and development, yet the literature on how various indexes of ANS activity develop in childhood is sparse. We utilized latent growth modeling to investigate the development of respiratory sinus arrhythmia (RSA), an established index of parasympathetic nervous system (PNS), and preejection period (PEP), a marker of sympathetic nervous system (SNS) influence on the heart, in children aged 8-10 years. At age 8, 251 children (128 girls, 123 boys; 162 European American, 89 African American) participated. Longitudinal data were collected during two additional waves when children were 9 and 10 years of age, with a 1-year lag between each wave. Children's RSA and PEP exhibited significant stability over time. Marginally significant variability was found among children in how RSA changed over time (slope), but there was no significant interindividual variability in PEP changes over development. A conditional growth curve model (i.e., one with predictor variables) showed that initial levels of RSA and PEP and the slope of RSA over time were predicted by several demographic factors including the child's sex and race; RSA of European American children showed significant increases over time while African American children had higher initial RSA but no significant change over time. Findings extend basic knowledge in developmental biopsychology and have implications for research focusing on ANS measures as important predictors, moderators, and mediators of childhood adaptation. © 2010 Wiley Periodicals, Inc.

  2. Determination of the S-wave scattering shape parameter P from the zero-energy wave function

    International Nuclear Information System (INIS)

    Kermode, M.W.; van Dijk, W.

    1990-01-01

    We show that for S-wave scattering at an energy k 2 by a local potential which supports no more than one bound state, the shape parameter P and coefficients of higher powers of k 2 in the effective range expansion function cotδ=-1/a+1/2 r 0 k 2 -Pr 0 3 k 3 +Qr 0 5 k 6 +..., where δ is the phase shift, may be obtained from the zero-energy wave function, u 0 (r). Thus δ itself may be determined from u 0 . We show that Pr 0 3 =∫ 0 R [β(r)u 0 2 (r)-bar β(r)bar u 0 2 (r)]dr, where r 0 is the effective range, β(r) is determined from an integral involving the wave function, and bar β(r) is a simple function of r which involves the scattering length and effective range

  3. Square vortex lattice in p-wave superconductors

    International Nuclear Information System (INIS)

    Shiraishi, J.

    1999-01-01

    Making use of the Ginzburg Landau equation for isotropic p-wave superconductors, we construct the single vortex solution in part analytically. The fourfold symmetry breaking term arising from the tetragonal symmetry distortion of the Fermi surface is crucial, since this term indicates a fourfold distortion of the vortex core somewhat similar to the one found in d-wave superconductors. This fourfold distortion of the vortex core in turn favors the square vortex lattice as observed recently by small angle neutron scattering (SANS) experiment from Sr 2 RuO 4 . We find that the hexagonal vortex lattice at H = H c1 transforms into the square one for H = H cr = 0.26 H c2 . On the other hand the SANS data does not reveal such transition. The square vortex covers everywhere studied by the SANS implying H cr is very close to H c1 . Therefore some improvement in the present model is certainly desirable. (orig.)

  4. Selective detection and recovery of gold at tannin-immobilized non-conducting electrode.

    Science.gov (United States)

    Banu, Khaleda; Shimura, Takayoshi; Sadeghi, Saman

    2015-01-01

    A tannin-immobilized glassy carbon electrode (TIGC) was prepared via electrochemical oxidation of the naturally occurring polyphenolic mimosa tannin, which generated a non-conducting polymeric film (NCPF) on the electrode surface. The fouling of the electrode surface by the electropolymerized film was evaluated by monitoring the electrode response of ferricyanide ions as a redox marker. The NCPF was permselective to HAuCl4, and the electrochemical reduction of HAuCl4 to metallic gold at the TIGC electrode was evaluated by recording the reduction current during cyclic voltammetry measurement. In the mixed electrolyte containing HAuCl4 along with FeCl3 and/or CuCl2, the NCPF remained selective toward the electrochemical reduction of HAuCl4 into the metallic state. The chemical reduction of HAuCl4 into metallic gold was also observed when the NCPF was inserted into an acidic gold solution overnight. The adsorption capacity of Au(III) on tannin-immobilized carbon fiber was 29±1.45 mg g(-1) at 60°C. In the presence of excess Cu(II) and Fe(III), tannin-immobilized NCPF proved to be an excellent candidate for the selective detection and recovery of gold through both electrochemical and chemical processes. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Controversies in Cardiovascular Research: Induced pluripotent stem cell-derived cardiomyocytes – boutique science or valuable arrhythmia model?

    Science.gov (United States)

    Knollmann, Björn C

    2013-01-01

    As part of the series on Controversies in Cardiovascular Research, the article reviews the strengths and limitations of induced pluripotent stem cell-derived cardiomyocytes (iPSC-CM) as models of cardiac arrhythmias. Specifically, the article attempts to answer the following questions: Which clinical arrhythmias can be modeled by iPSC-CM? How well can iPSC-CM model adult ventricular myocytes? What are the strengths and limitations of published iPSC-CM arrhythmia models? What new mechanistic insight has been gained? What is the evidence that would support using iPSC-CM to personalize anti-arrhythmic drug therapy? The review also discusses the pros and cons of using the iPSC-CM technology for modeling specific genetic arrhythmia disorders such as long QT syndrome, Brugada Syndrome or Catecholaminergic Polymorphic Ventricular Tachycardia. PMID:23569106

  6. Electroversion in treatment of arrhythmia in a patient with Wolff-Parkinson-White syndrome and cervical spinal cord injury

    Directory of Open Access Journals (Sweden)

    SHEN Peng

    2013-06-01

    Full Text Available 【Abstract】We report electroversion in treatment of atrial fibrillation (AF and atrioventricular nodal reentry ta-chycardia (AVNRT in a patient with Wolff-Parkinson-White syndrome and cervical spinal cord injury. At first, the pa-tient sustained respiratory failure and weak cough reflex, thereafter repeated bronchoscopy was used to aspirate the sputum as well as control the pneumonia, which resulted in arrhythmia (AF and AVNRT. Two doses of intravenous amiodarone failed to correct the arrhythmia. After restora-tion of sinus rhythm by electroversion, he was successfully weaned from mechanical ventilation and discharged from the intensive care unit without recurrent arrhythmia. Key words: Arrhythmia, cardiac; Atrial fibrillation; Electric countershock; Wolff-Parkinson-White syndrome; Spinal cord injuries

  7. Novel energy modalities for catheter ablation of cardiac arrhythmias : Pitfalls and possibilities of potent power sources

    NARCIS (Netherlands)

    Neven, K.G.E.J.

    2014-01-01

    The acceptance of catheter ablation as treatment for cardiac arrhythmias is amongst others dependent on its success rate, a high initial success rate will increase physician and patient acceptance. One of the reasons why recurrence of arrhythmia after ablation is substantial is non-transmurality of

  8. Analytical solution for the transient wave propagation of a buried cylindrical P-wave line source in a semi-infinite elastic medium with a fluid surface layer

    Science.gov (United States)

    Shan, Zhendong; Ling, Daosheng

    2018-02-01

    This article develops an analytical solution for the transient wave propagation of a cylindrical P-wave line source in a semi-infinite elastic solid with a fluid layer. The analytical solution is presented in a simple closed form in which each term represents a transient physical wave. The Scholte equation is derived, through which the Scholte wave velocity can be determined. The Scholte wave is the wave that propagates along the interface between the fluid and solid. To develop the analytical solution, the wave fields in the fluid and solid are defined, their analytical solutions in the Laplace domain are derived using the boundary and interface conditions, and the solutions are then decomposed into series form according to the power series expansion method. Each item of the series solution has a clear physical meaning and represents a transient wave path. Finally, by applying Cagniard's method and the convolution theorem, the analytical solutions are transformed into the time domain. Numerical examples are provided to illustrate some interesting features in the fluid layer, the interface and the semi-infinite solid. When the P-wave velocity in the fluid is higher than that in the solid, two head waves in the solid, one head wave in the fluid and a Scholte wave at the interface are observed for the cylindrical P-wave line source.

  9. Interactive Micromanipulation of Picking and Placement of Nonconductive Microsphere in Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Ning Cao

    2017-08-01

    Full Text Available In this paper, classified theoretical models, consisting of contact with and placement of microsphere and picking operations, are simplified and established to depict the interactive behaviors of external and internal forces in pushing manipulations, respectively. Sliding and/or rolling cases, resulting in the acceleration of micromanipulations, are discussed in detail. Effective contact detection is achieved by combining alterations of light-shadow and relative movement displacement between the tip-sphere. Picking operations are investigated by typical interactive positions and different end tilt angles. Placements are realized by adjusting the proper end tilt angles. These were separately conducted to explore the interactive operations of nonconductive glass microspheres in a scanning electron microscope. The experimental results demonstrate that the proposed contact detection method can efficiently protect the end-tip from damage, regardless of operator skills in initial positioning operations. E-beam irradiation onto different interactive positions with end tilt angles can be utilized to pick up microspheres without bending the end-tip. In addition, the results of releasing deviations away from the pre-setting point were utilized to verify the effectiveness of the placement tilt angles.

  10. Growth of electron plasma waves above and below f/sub p/ in the electron foreshock

    International Nuclear Information System (INIS)

    Cairns, I.H.; Fung, S.F.

    1988-01-01

    With increasing penetration into the electron foreshock the characteristics of the electrostatic waves driven by streaming electrons change continuously from the familiar intense waves near the electron plasma frequency f/sub p/ to weak bursts of broadband waves initially significantly above f/sub p/ and then well below f/sub p/. Growth well below f/sub p/ has been demonstrated theoretically for slow, cold electron beams, and the broadband waves below f/sub p/ in the foreshock have been interpreted in terms of the very cold or sharp ''cutoff'' feature of a cutoff distribution for small cutoff speeds. However, an approximate theoretical criterion indicates that the electron beams studied hitherto are unstable to reactive rather than kinetic growth, thereby favoring very narrow-band growth contrary to the observed broadband growth. In this paper we determine conditions for kinetic growth well above and below f/sub p/ for both cold and warm beams over a wide range of beam densities and speeds. We verify that kinetic growth below f/sub p/ is possible for cold, slow beams and for warm, dense beams (over wide range of beam velocities)

  11. Symmetrical compression distance for arrhythmia discrimination in cloud-based big-data services.

    Science.gov (United States)

    Lillo-Castellano, J M; Mora-Jiménez, I; Santiago-Mozos, R; Chavarría-Asso, F; Cano-González, A; García-Alberola, A; Rojo-Álvarez, J L

    2015-07-01

    The current development of cloud computing is completely changing the paradigm of data knowledge extraction in huge databases. An example of this technology in the cardiac arrhythmia field is the SCOOP platform, a national-level scientific cloud-based big data service for implantable cardioverter defibrillators. In this scenario, we here propose a new methodology for automatic classification of intracardiac electrograms (EGMs) in a cloud computing system, designed for minimal signal preprocessing. A new compression-based similarity measure (CSM) is created for low computational burden, so-called weighted fast compression distance, which provides better performance when compared with other CSMs in the literature. Using simple machine learning techniques, a set of 6848 EGMs extracted from SCOOP platform were classified into seven cardiac arrhythmia classes and one noise class, reaching near to 90% accuracy when previous patient arrhythmia information was available and 63% otherwise, hence overcoming in all cases the classification provided by the majority class. Results show that this methodology can be used as a high-quality service of cloud computing, providing support to physicians for improving the knowledge on patient diagnosis.

  12. TRACING p -MODE WAVES FROM THE PHOTOSPHERE TO THE CORONA IN ACTIVE REGIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Junwei; Chen, Ruizhu [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305-4085 (United States); Felipe, Tobías; Khomenko, Elena [Instituto de Astrofísica de Canarias, E-38025 La Laguna, Tenerife (Spain)

    2016-10-10

    Atmosphere above sunspots is abundant with different types of waves. Among these waves are running penumbral waves in the chromosphere, quasi-periodic oscillations in the lower coronal loops, and recently reported running waves in sunspots’ photosphere, all of which were interpreted as magnetoacoustic waves by some authors. Are these waves in different atmospheric layers related to each other, what is the nature of these waves, and where are the ultimate sources of these waves? Applying a time–distance helioseismic analysis over a suite of multi-wavelength observations above a sunspot, we demonstrate that the helioseismic p -mode waves are able to channel up from the photosphere through the chromosphere and transition region into the corona, and that the magnetoacoustic waves observed in different atmospheric layers are a same wave originating from the photosphere but exhibiting differently under different physical conditions. We also show waves of different frequencies travel along different paths, which can be used to derive the physical properties of the atmosphere above sunspots. Our numerical simulation of traveling of waves from a subphotospheric source qualitatively resembles the observed properties of the waves and offers an interpretation of the shapes of the wavefronts above the photosphere.

  13. Hybrid Theory of P-Wave Electron-Hydrogen Elastic Scattering

    Science.gov (United States)

    Bhatia, Anand

    2012-01-01

    We report on a study of electron-hydrogen scattering, using a combination of a modified method of polarized orbitals and the optical potential formalism. The calculation is restricted to P waves in the elastic region, where the correlation functions are of Hylleraas type. It is found that the phase shifts are not significantly affected by the modification of the target function by a method similar to the method of polarized orbitals and they are close to the phase shifts calculated earlier by Bhatia. This indicates that the correlation function is general enough to include the target distortion (polarization) in the presence of the incident electron. The important fact is that in the present calculation, to obtain similar results only 35-term correlation function is needed in the wave function compared to the 220-term wave function required in the above-mentioned previous calculation. Results for the phase shifts, obtained in the present hybrid formalism, are rigorous lower bounds to the exact phase shifts.

  14. Arctigenin, a Potential Anti-Arrhythmic Agent, Inhibits Aconitine-Induced Arrhythmia by Regulating Multi-Ion Channels

    Directory of Open Access Journals (Sweden)

    Zhenying Zhao

    2013-11-01

    Full Text Available Background/Aims: Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. Methods: A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD, sodium current (INa, L-type calcium current (ICa, L and transient outward potassium current (Ito were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Results: Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90 were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited INa and ICa,L and attenuated the aconitine-increased INa and ICa,L by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Conclusions: Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, INa, ICa, L, and Ito may be multiple targets of arctigenin, leading to its antiarrhythmic effect.

  15. Dynamic Response of Underground Circular Lining Tunnels Subjected to Incident P Waves

    Directory of Open Access Journals (Sweden)

    Hua Xu

    2014-01-01

    Full Text Available Dynamic stress concentration in tunnels and underground structures during earthquakes often leads to serious structural damage. A series solution of wave equation for dynamic response of underground circular lining tunnels subjected to incident plane P waves is presented by Fourier-Bessel series expansion method in this paper. The deformation and stress fields of the whole medium of surrounding rock and tunnel were obtained by solving the equations of seismic wave propagation in an elastic half space. Based on the assumption of a large circular arc, a series of solutions for dynamic stress were deduced by using a wave function expansion approach for a circular lining tunnel in an elastic half space rock medium subjected to incident plane P waves. Then, the dynamic response of the circular lining tunnel was obtained by solving a series of algebraic equations after imposing its boundary conditions for displacement and stress of the circular lining tunnel. The effects of different factors on circular lining rock tunnels, including incident frequency, incident angle, buried depth, rock conditions, and lining stiffness, were derived and several application examples are presented. The results may provide a good reference for studies on the dynamic response and aseismic design of tunnels and underground structures.

  16. Comparison of two teaching methods for cardiac arrhythmia interpretation among nursing students.

    Science.gov (United States)

    Varvaroussis, Dimitrios P; Kalafati, Maria; Pliatsika, Paraskevi; Castrén, Maaret; Lott, Carsten; Xanthos, Theodoros

    2014-02-01

    The aim of this study was to compare the six-stage method (SSM) for instructing primary cardiac arrhythmias interpretation to students without basic electrocardiogram (ECG) knowledge with a descriptive teaching method in a single educational intervention. This is a randomized trial. Following a brief instructional session, undergraduate nursing students, assigned to group A (SSM) and group B (descriptive teaching method), undertook a written test in cardiac rhythm recognition, immediately after the educational intervention (initial exam). Participants were also examined with an unannounced retention test (final exam), one month after instruction. Altogether 134 students completed the study. Interpretation accuracy for each cardiac arrhythmia was assessed. Mean score at the initial exam was 8.71±1.285 for group A and 8.74±1.303 for group B. Mean score at the final exam was 8.25±1.46 for group A vs 7.84±1.44 for group B. Overall results showed that the SSM was equally effective with the descriptive teaching method. The study showed that in each group bradyarrhythmias were identified correctly by more students than tachyarrhythmias. No significant difference between the two teaching methods was seen for any specific cardiac arrhythmia. The SSM effectively develops staff competency for interpreting common cardiac arrhythmias in students without ECG knowledge. More research is needed to support this conclusion and the method's effectiveness must be evaluated if being implemented to trainee groups with preexisting basic ECG interpretation knowledge. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Waveform inversion for orthorhombic anisotropy with P-waves: feasibility & resolution

    KAUST Repository

    Kazei, Vladimir; Alkhalifah, Tariq Ali

    2018-01-01

    Various parameterizations have been suggested to simplify inversions of first arrivals, or Pwaves, in orthorhombic anisotropic media, but the number and type of retrievable parameters have not been decisively determined. We show that only six

  18. Finite nuclear size and Lamb shift of p-wave atomic states

    International Nuclear Information System (INIS)

    Milstein, A.I.; Sushkov, O.P.; Terekhov, I.S.

    2003-01-01

    We consider corrections to the Lamb shift of the p-wave atomic states due to the finite nuclear size (FNS). In other words, these are radiative corrections to the atomic isotope shift related to the FNS. It is shown that the structure of the corrections is qualitatively different to that for the s-wave states. The perturbation theory expansion for the relative correction for a p 1/2 state starts with a α ln(1/Zα) term, while for the s 1/2 states it starts with a Zα 2 term. Here, α is the fine-structure constant and Z is the nuclear charge. In the present work, we calculate the α terms for that 2p states, the result for the 2p 1/2 state reads (8α/9π){ln[1/(Zα) 2 ]+0.710}. Even more interesting are the p 3/2 states. In this case the 'correction' is several orders of magnitude larger than the 'leading' FNS shift. However, absolute values of energy shifts related to these corrections are very small

  19. Cardiac Arrhythmia: Atrial Flutter in a Newborn. Case Study

    Directory of Open Access Journals (Sweden)

    T.M. Klimenko

    2014-09-01

    Full Text Available The article gives case report of rare in neonatal period cardiac arrhythmia — atrial flutter. The disease is one of the manifestations of life-threatening heart rhythm disorders, has no characteristic clinical picture, is diagnosed only by means of an electrocardiogram.

  20. Modeling the effects of electrical and non-electrical parameters on the material removal and surface integrity in case of µEDM of a non-conductive ceramic material using a combined fuzzy-AOM approach

    DEFF Research Database (Denmark)

    Puthumana, Govindan

    2016-01-01

    Micro-EDM is a non-contact process based on the thermoelectric energy between a tool electrode and a workpiece. In μEDM process, the mechanism of material removal is melting and evaporation. The thermal energy in the discharge plasma helps remove material from the workpiece, at the same time...... and surface integrity for a non-conductive ceramic material. The fuzzy logic modeling system is employed for predicting the μEDM process responses. The trends in the material removal rate and hardness values with the chosen electrical and non-electrical parameter for the model and obtained using AOM approach...... are compared. The average deviation between the model predictions and the results obtained using AOM plots is less than 10%. The material removal rate (MRR) decreases linearly with voltage, indicating a difference in material removal mechanism in the μEDM of non-conductive materials....

  1. Wave refraction and backward magnon-plasmon polaritons in left-handed antiferromagnet/semiconductor superlattices

    International Nuclear Information System (INIS)

    Tarkhanyan, R.H.; Niarchos, D.G.

    2007-01-01

    Characteristics of the bulk electromagnetic waves in teraHertz frequency region are examined in a left-handed superlattice (SL) which consists of alternating layers of nonmagnetic semiconductor and nonconducting antiferromagnetic materials. General problem on the sign of the refractive index for anisotropic media is considered. It is shown that the phase refraction index is always positive while the group refractive index can be negative when some general conditions are fulfilled. Effective permittivity and permeability tensors of the SL are derived for perpendicular and parallel orientation of the magnetic anisotropy axis with respect to the plane of the layers. Problem of anomalous refraction for transverse electric and transverse magnetic-type polarized waves is examined in such media. Analytical expressions for both the phase and group refractive indices are obtained for various propagated modes. It is shown that, in general, three different types of the refracted waves with different relative orientation of the phase and group velocity vectors are possible in left-handed media. Unusual peculiarities of the backward modes corresponding to the coupled magnon-plasmon polaritons are considered. It is shown, in particular, that the number of the backward modes depends on the free charge carrier's density in semiconductor layers, variation of which allows to create different frequency regions for the wave propagation

  2. Design and modeling of InP DHBT power amplifiers at millimeter-wave frequencies

    DEFF Research Database (Denmark)

    Yan, Lei; Johansen, Tom K.

    2012-01-01

    In this paper, the design and modeling of InP DHBT based millimeter-wave(mm-wave) power amplifiers is described. This includes the modeling of InP DHBT devices and layout parasitics. An EM-circuit co-simulation approach is described to allow all parasitics to be modeled for accurate circuit...... demonstrates a power gain of 4.5dB with a saturated output power of 14.2dBm at 69.2GHz. © 2012 European Microwave Assoc....

  3. Can P wave wavelet analysis predict atrial fibrillation after coronary artery bypass grafting?

    Science.gov (United States)

    Vassilikos, Vassilios; Dakos, George; Chouvarda, Ioanna; Karagounis, Labros; Karvounis, Haralambos; Maglaveras, Nikolaos; Mochlas, Sotirios; Spanos, Panagiotis; Louridas, George

    2003-01-01

    The purpose of this study was the evaluation of Morlet wavelet analysis of the P wave as a means of predicting the development of atrial fibrillation (AF) in patients who undergo coronary artery bypass grafting (CABG). The P wave was analyzed using the Morlet wavelet in 50 patients who underwent successful CABG. Group A consisted of 17 patients, 12 men and 5 women, of mean age 66.9 +/- 5.9 years, who developed AF postoperatively. Group B consisted of 33 patients, 29 men and 4 women, mean age 62.4 +/- 7.8 years, who remained arrhythmid-free. Using custom-designed software, P wave duration and wavelet parameters expressing the mean and maximum energy of the P wave were calculated from 3-channel digital recordings derived from orthogonal ECG leads (X, Y, and Z), and the vector magnitude (VM) was determined in each of 3 frequency bands (200-160 Hz, 150-100 Hz and 90-50 Hz). Univariate logistic-regression analysis identified a history of hypertension, the mean and maximum energies in all frequency bands along the Z axis, the mean and maximum energies (expressed by the VM) in the 200-160 Hz frequency band, and the mean energy in the 150-100 Hz frequency band along the Y axis as predictors for post-CABG AF. Multivariate analysis identified hypertension, ejection fraction, and the maximum energies in the 90-50 Hz frequency band along the Z and composite-vector axes as independent predictors. This multivariate model had a sensitivity of 91% and a specificity of 65%. We conclude that the Morlet wavelet analysis of the P wave is a very sensitive method of identifying patients who are likely to develop AF after CABG. The occurrence of post-CABG AF can be explained by a different activation pattern along the Z axis.

  4. TITERS OF ANTIBODIES TO Β1-ADRENOCEPTOR AND M2 CHOLINERGIC RECEPTORS IN PATIENTS WITH VENTRICULAR ARRHYTHMIAS WITHOUT AN ORGANIC CARDIOVASCULAR DISEASE AND THEIR POSSIBLE CLINICAL SIGNIFICANCE

    Directory of Open Access Journals (Sweden)

    M. M. Rogova

    2012-01-01

    Full Text Available Aim. To identify the most promising epitopes that simulate various sites β1-adrenergic and M2-cholinergic receptors, and to evaluate their possible contribution to the development and maintenance of cardiac arrhythmias, particularly idiopathic ventricular arrhythmia. Material and methods. Patients with ventricular arrhythmias without organic cardiovascular disease (the study group; n=70 were included in the study. The control group consisted of 20 healthy volunteers. Evaluation of levels of antibodies to antigenic determinants, modeling various sites β1-adrenergic and M2-cholinergic performed in all patients. Causal treatment with clarithromycin and valacyclovir performed in part of patients. Results. Antibodies to different peptide sequences of β1-adrenergic and M2-cholinergic receptors have been identified in 25% of main group patients. A direct correlation between the frequency of episodes of ventricular tachycardia and IgG levels to MRI-MRIV (p=0.02 revealed. Increase in titre of antibodies to β1-adrenoceptors, to a peptide sequence β8 (p=0.02, and lower titers of antibodies to the M2 acetylcholine receptor — chimera MRI-MRIV IgM (p=0.06 and ARI-MRIV IgM (p=0.07 were observed when assessing the efficacy of the therapy in the causal dynamics in the group of "untreated" patients. IgG titer reduction of ARI-MRIV (p=0.02, which is 4 times out of 10 with reduction of ventricular ectopic activity , recorded after valacyclovir therapy. Clarithromycin therapy on the level of antibodies exerted no significant effect. Conclusion. Possible involvement of antibodies to β1-adrenoceptor and M2-cholinergic receptors in the development of idiopathic ventricular arrhythmias demonstrated. The relationship between the frequency of episodes of ventricular tachycardia and levels of antibody titers to M2-cholinergic receptors found. Attempt of causal treatment, depending on the possible mechanisms of the autoimmune process is executed. Further studies to

  5. Evaluation of P-Wave Dispersion, Diastolic Function, and Atrial Electromechanical Conduction in Pediatric Patients with Subclinical Hypothyroidism.

    Science.gov (United States)

    Irdem, Ahmet; Aydın Sahin, Derya; Kervancioglu, Mehmet; Baspinar, Osman; Sucu, Murat; Keskin, Mehmet; Kilinc, Metin

    2016-09-01

    This study aimed to evaluate ventricular diastolic dysfunction, inter- and intraatrial conduction delay, and P-wave dispersion in pediatric patients with subclinical hypothyroidism. The study comprised a total of 30 pediatric patients with subclinical hypothyroidism (SH) (mean age 7.8 ± 3.2 years) and 30 healthy children (mean age 8.4 ± 3.6 years) as the control group. A SH diagnosis was made in the event of increased serum thyroid-stimulating hormone (TSH) and decreased serum free triiodothyronine (T3 ) and free thyroxine (T4 ) concentrations. Conventional Doppler imaging (TDI) showed low mitral early diastolic E-wave velocity and E/A ratio (P wave velocity (P = 0.001) in hypothyroidism patients. Moreover, patients with hypothyroidism had significantly lower left ventricular (LV) septal Em velocity and Em /Am ratios compared with the control group (P wave dispersion was significantly different in the pediatric patients with hypothyroidism (P wave dispersion, and ventricle diastolic dysfunction in pediatric patients with hypothyroidism. © 2016, Wiley Periodicals, Inc.

  6. Hereditary arrhythmias and cardiomyopathies: decision-making about genetic testing.

    Science.gov (United States)

    Louis, Clauden; Calamaro, Emily; Vinocur, Jeffrey M

    2018-01-01

    The modern field of clinical genetics has advanced beyond the traditional teachings familiar to most practicing cardiologists. Increased understanding of the roles of genetic testing may improve uptake and appropriateness of use. Clinical genetics has become integral to the management of patients with hereditary arrhythmia and cardiomyopathy diagnoses. Depending on the condition, genetic testing may be useful for diagnosis, prognosis, treatment, family screening, and reproductive planning. However, genetic testing is a powerful tool with potential for underuse, overuse, and misuse. In the absence of a substantial body of literature on how these guidelines are applied in clinical practice, we use a case-based approach to highlight key lessons and pitfalls. Importantly, in many scenarios genetic testing has become the standard of care supported by numerous class I recommendations; genetic counselors can improve accessibility to and appropriate use and application of testing. Optimal management of hereditary arrhythmias and cardiomyopathies incorporates genetic testing, applied as per consensus guidelines, with involvement of a multidisciplinary team.

  7. Arctigenin, a potential anti-arrhythmic agent, inhibits aconitine-induced arrhythmia by regulating multi-ion channels.

    Science.gov (United States)

    Zhao, Zhenying; Yin, Yongqiang; Wu, Hong; Jiang, Min; Lou, Jianshi; Bai, Gang; Luo, Guo'an

    2013-01-01

    Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD), sodium current (I(Na)), L-type calcium current (I(Ca, L)) and transient outward potassium current (I(to)) were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90) were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited I(Na) and I(Ca,L) and attenuated the aconitine-increased I(Na) and I(Ca,L) by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, I(Na), I(Ca, L), and I(to) may be multiple targets of arctigenin, leading to its antiarrhythmic effect. © 2013 S. Karger AG, Basel.

  8. Possible influence of the polarity reversal of the solar magnetic field on the various types of arrhythmias

    International Nuclear Information System (INIS)

    Giannaropoulou, E; Papailiou, M; Mavromichalaki, H; Preka-Papadema, P; Gigolashvili, M; Tvildiani, L; Janashia, K; Papadima, Th

    2013-01-01

    Over the last few years various researches have reached the conclusion that cosmic ray variations and geomagnetic disturbances are related to the condition of the human physiological state. In this study medical data concerning the number of incidents of different types of cardiac arrhythmias for the time period 1983 – 1992 which refer to 1902 patients in Tbilisi, Georgia were used. The smoothing method and the Pearson r-coefficients were used to examine the possible effect of different solar and geomagnetic activity parameters and cosmic ray intensity variations on the different types of arrhythmias. The time interval under examination was separated into two different time periods which coincided with the polarity reversal of the solar magnetic field that occurred in the years 1989-1990 and as a result a different behavior of all the above mentioned parameters as well as of the different types of arrhythmias was noticed during the two time intervals. In addition, changing of polarity sign of the solar magnetic field was found to affect the sign of correlation between the incidence of arrhythmias and the aforementioned parameters. The primary and secondary maxima observed in the solar parameters during the solar cycle 22, also appeared in several types of arrhythmias with a time lag of about five months.

  9. New results on the Roper resonance and the P{sub 11} partial wave

    Energy Technology Data Exchange (ETDEWEB)

    Sarantsev, A.V. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Fuchs, M. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Kotulla, M. [Physikalisches Institut, Universitaet Basel (Switzerland); II. Physikalisches Institut, Universitaet Giessen (Germany); Thoma, U. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); II. Physikalisches Institut, Universitaet Giessen (Germany); Ahrens, J. [Institut fuer Kernphysik, Universitaet Mainz (Germany); Annand, J.R.M. [Department of Physics and Astronomy, University of Glasgow (United Kingdom); Anisovich, A.V. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Anton, G. [Physikalisches Institut, Universitaet Erlangen (Germany); Bantes, R. [Physikalisches Institut, Universitaet Bonn (Germany); Bartholomy, O. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Beck, R. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Institut fuer Kernphysik, Universitaet Mainz (Germany); Beloglazov, Yu. [Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Castelijns, R. [KVI, Groningen (Netherlands); Crede, V. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Department of Physics, Florida State University (United States); Ehmanns, A.; Ernst, J.; Fabry, I. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany); Flemming, H. [Physikalisches Institut, Universitaet Bochum (Germany); Foesel, A. [Physikalisches Institut, Universitaet Erlangen (Germany); Funke, Chr. [Helmholtz-Institut fuer Strahlen- und Kernphysik der Universitaet Bonn (Germany)] (and others)

    2008-01-17

    Properties of the Roper resonance, the first scalar excitation of the nucleon, are determined. Pole positions and residues of the P{sub 11} partial wave are studied in a combined analysis of pion- and photo-induced reactions. We find the Roper pole at {l_brace}(1371{+-}7)-i(92{+-}10){r_brace} MeV and an elasticity of 0.61{+-}0.03. The largest decay coupling is found for the N{sigma} ({sigma}=({pi}{pi})-S-wave). The analysis is based on new data on {gamma}p{yields}p{pi}{sup 0}{pi}{sup 0} for photons in the energy range from the two-pion threshold to 820 MeV from TAPS at Mainz and from 0.4 to 1.3 GeV from Crystal Barrel at Bonn and includes further data from other experiments. The partial wave analysis excludes the possibility that the Roper resonance is split into two states with different partial decay widths.

  10. 3D elastic full waveform inversion using P-wave excitation amplitude: Application to OBC field data

    KAUST Repository

    Oh, Juwon; Kalita, Mahesh; Alkhalifah, Tariq Ali

    2017-01-01

    We propose an efficient elastic full waveform inversion (FWI) based on the P-wave excitation amplitude (maximum energy arrival) approximation in the source wavefields. Because, based on the P-wave excitation approximation (ExA), the gradient direction is approximated by the cross-correlation of source and receiver wavefields at only excitation time, it estimates the gradient direction faster than its conventional counterpart. In addition to this computational speedup, the P-wave excitation approximation automatically ignores SP and SS correlations in the approximated gradient direction. In elastic FWI for ocean bottom cable (OBC) data, the descent direction for the S-wave velocity is often degraded by undesired long-wavelength features from the SS correlation. For this reason, the P-wave excitation approach increases the convergence rate of multi-parameter FWI compared to the conventional approach. The modified 2D Marmousi model with OBC acquisition is used to verify the differences between the conventional method and ExA. Finally, the feasibility of the proposed method is demonstrated on a real OBC data from North Sea.

  11. 3D elastic full waveform inversion using P-wave excitation amplitude: Application to OBC field data

    KAUST Repository

    Oh, Juwon

    2017-12-05

    We propose an efficient elastic full waveform inversion (FWI) based on the P-wave excitation amplitude (maximum energy arrival) approximation in the source wavefields. Because, based on the P-wave excitation approximation (ExA), the gradient direction is approximated by the cross-correlation of source and receiver wavefields at only excitation time, it estimates the gradient direction faster than its conventional counterpart. In addition to this computational speedup, the P-wave excitation approximation automatically ignores SP and SS correlations in the approximated gradient direction. In elastic FWI for ocean bottom cable (OBC) data, the descent direction for the S-wave velocity is often degraded by undesired long-wavelength features from the SS correlation. For this reason, the P-wave excitation approach increases the convergence rate of multi-parameter FWI compared to the conventional approach. The modified 2D Marmousi model with OBC acquisition is used to verify the differences between the conventional method and ExA. Finally, the feasibility of the proposed method is demonstrated on a real OBC data from North Sea.

  12. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  13. Unique Association of Rare Cardiovascular Disease in an Athlete With Ventricular Arrhythmias.

    Science.gov (United States)

    Santomauro, V; Contursi, M; Dellegrottaglie, S; Borsellino, G

    2015-01-01

    Ventricular arrhythmias are a leading cause of non-elegibility to competitive sport. The failure to detect a significant organic substrate in the initial stage of screening does not preclude the identification of structural pathologies in the follow-up by using advanced imaging techniques. Here we report the case of a senior athlete judged not elegible because an arrhythmia with the morphology consistent with the origin of the left ventricle, in which subsequent execution of a cardiac MR and a thoracic CT scan has allowed the identification of an unique association between an area of myocardial damage, probable site of origine of the arrhythma, and a rare aortic malformation.

  14. Non-overlapped P- and S-wave Poynting vectors and its solution on Grid Method

    KAUST Repository

    Lu, Yong Ming; Liu, Qiancheng

    2017-01-01

    Poynting vector represents the local directional energy flux density of seismic waves in geophysics. It is widely used in elastic reverse time migration (RTM) to analyze source illumination, suppress low-wavenumber noise, correct for image polarity and extract angle-domain common imaging gather (ADCIG). However, the P and S waves are mixed together during wavefield propagation such that the P and S energy fluxes are not clean everywhere, especially at the overlapped points. In this paper, we use a modified elastic wave equation in which the P and S vector wavefields are naturally separated. Then, we develop an efficient method to evaluate the separable P and S poynting vectors, respectively, based on the view that the group velocity and phase velocity have the same direction in isotropic elastic media. We furthermore formulate our method using an unstructured mesh based modeling method named the grid method. Finally, we verify our method using two numerical examples.

  15. Non-overlapped P- and S-wave Poynting vectors and its solution on Grid Method

    KAUST Repository

    Lu, Yong Ming

    2017-12-12

    Poynting vector represents the local directional energy flux density of seismic waves in geophysics. It is widely used in elastic reverse time migration (RTM) to analyze source illumination, suppress low-wavenumber noise, correct for image polarity and extract angle-domain common imaging gather (ADCIG). However, the P and S waves are mixed together during wavefield propagation such that the P and S energy fluxes are not clean everywhere, especially at the overlapped points. In this paper, we use a modified elastic wave equation in which the P and S vector wavefields are naturally separated. Then, we develop an efficient method to evaluate the separable P and S poynting vectors, respectively, based on the view that the group velocity and phase velocity have the same direction in isotropic elastic media. We furthermore formulate our method using an unstructured mesh based modeling method named the grid method. Finally, we verify our method using two numerical examples.

  16. Improvement of a picking algorithm real-time P-wave detection by kurtosis

    Science.gov (United States)

    Ishida, H.; Yamada, M.

    2016-12-01

    Earthquake early warning (EEW) requires fast and accurate P-wave detection. The current EEW system in Japan uses the STA/LTAalgorithm (Allen, 1978) to detect P-wave arrival.However, some stations did not trigger during the 2011 Great Tohoku Earthquake due to the emergent onset. In addition, accuracy of the P-wave detection is very important: on August 1, 2016, the EEW issued a false alarm with M9 in Tokyo region due to a thunder noise.To solve these problems, we use a P-wave detection method using kurtosis statistics. It detects the change of statistic distribution of the waveform amplitude. This method was recently developed (Saragiotis et al., 2002) and used for off-line analysis such as making seismic catalogs. To apply this method for EEW, we need to remove an acausal calculation and enable a real-time processing. Here, we propose a real-time P-wave detection method using kurtosis statistics with a noise filter.To avoid false triggering by a noise, we incorporated a simple filter to classify seismic signal and noise. Following Kong et al. (2016), we used the interquartilerange and zero cross rate for the classification. The interquartile range is an amplitude measure that is equal to the middle 50% of amplitude in a certain time window. The zero cross rate is a simple frequency measure that counts the number of times that the signal crosses baseline zero. A discriminant function including these measures was constructed by the linear discriminant analysis.To test this kurtosis method, we used strong motion records for 62 earthquakes between April, 2005 and July, 2015, which recorded the seismic intensity greater equal to 6 lower in the JMA intensity scale. The records with hypocentral distance picks. It shows that the median error is 0.13 sec and 0.035 sec for STA/LTA and kurtosis method. The kurtosis method tends to be more sensitive to small changes in amplitude.Our approach will contribute to improve the accuracy of source location determination of

  17. Dynamics of Endo- and Epicardial Focal Fibrillation Waves at the Right Atrium in a Patient With Advanced Atrial Remodelling.

    Science.gov (United States)

    van der Does, Lisette J M E; Kik, Charles; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S

    2016-10-01

    Focal waves appear frequently at the epicardium during persistent atrial fibrillation (AF), however, the origin of these waves is under debate. We performed simultaneous endo-epicardial mapping of the right atrial wall during longstanding persistent AF in a patient undergoing cardiac surgery. During 10 seconds 53 and 59 focal waves appeared at random at respectively the endocardium and epicardium. Repetitive focal activity did not last longer than 3 cycles. Transmural asynchrony and conduction might be the origin of focal waves. Asynchronous propagation of fibrillation waves in 3 dimensions would stabilize the arrhythmia and could explain the limited success of persistent AF ablation. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Strong CMB constraint on P-wave annihilating dark matter

    Directory of Open Access Journals (Sweden)

    Haipeng An

    2017-10-01

    Full Text Available We consider a dark sector consisting of dark matter that is a Dirac fermion and a scalar mediator. This model has been extensively studied in the past. If the scalar couples to the dark matter in a parity conserving manner then dark matter annihilation to two mediators is dominated by the P-wave channel and hence is suppressed at very low momentum. The indirect detection constraint from the anisotropy of the Cosmic Microwave Background is usually thought to be absent in the model because of this suppression. In this letter we show that dark matter annihilation via bound state formation occurs through the S-wave and hence there is a constraint on the parameter space of the model from the Cosmic Microwave Background.

  19. Acute effects of sex steroid hormones on susceptibility to cardiac arrhythmias: a simulation study.

    Directory of Open Access Journals (Sweden)

    Pei-Chi Yang

    2010-01-01

    Full Text Available Acute effects of sex steroid hormones likely contribute to the observation that post-pubescent males have shorter QT intervals than females. However, the specific role for hormones in modulating cardiac electrophysiological parameters and arrhythmia vulnerability is unclear. Here we use a computational modeling approach to incorporate experimentally measured effects of physiological concentrations of testosterone, estrogen and progesterone on cardiac ion channel targets. We then study the hormone effects on ventricular cell and tissue dynamics comprised of Faber-Rudy computational models. The "female" model predicts changes in action potential duration (APD at different stages of the menstrual cycle that are consistent with clinically observed QT interval fluctuations. The "male" model predicts shortening of APD and QT interval at physiological testosterone concentrations. The model suggests increased susceptibility to drug-induced arrhythmia when estradiol levels are high, while testosterone and progesterone are apparently protective. Simulations predict the effects of sex steroid hormones on clinically observed QT intervals and reveal mechanisms of estrogen-mediated susceptibility to prolongation of QT interval. The simulations also indicate that acute effects of estrogen are not alone sufficient to cause arrhythmia triggers and explain the increased risk of females to Torsades de Pointes. Our results suggest that acute effects of sex steroid hormones on cardiac ion channels are sufficient to account for some aspects of gender specific susceptibility to long-QT linked arrhythmias.

  20. Design of a hybrid model for cardiac arrhythmia classification based on Daubechies wavelet transform.

    Science.gov (United States)

    Rajagopal, Rekha; Ranganathan, Vidhyapriya

    2018-06-05

    Automation in cardiac arrhythmia classification helps medical professionals make accurate decisions about the patient's health. The aim of this work was to design a hybrid classification model to classify cardiac arrhythmias. The design phase of the classification model comprises the following stages: preprocessing of the cardiac signal by eliminating detail coefficients that contain noise, feature extraction through Daubechies wavelet transform, and arrhythmia classification using a collaborative decision from the K nearest neighbor classifier (KNN) and a support vector machine (SVM). The proposed model is able to classify 5 arrhythmia classes as per the ANSI/AAMI EC57: 1998 classification standard. Level 1 of the proposed model involves classification using the KNN and the classifier is trained with examples from all classes. Level 2 involves classification using an SVM and is trained specifically to classify overlapped classes. The final classification of a test heartbeat pertaining to a particular class is done using the proposed KNN/SVM hybrid model. The experimental results demonstrated that the average sensitivity of the proposed model was 92.56%, the average specificity 99.35%, the average positive predictive value 98.13%, the average F-score 94.5%, and the average accuracy 99.78%. The results obtained using the proposed model were compared with the results of discriminant, tree, and KNN classifiers. The proposed model is able to achieve a high classification accuracy.

  1. Balancing surface adsorption and diffusion of lithium-polysulfides on nonconductive oxides for lithium-sulfur battery design.

    Science.gov (United States)

    Tao, Xinyong; Wang, Jianguo; Liu, Chong; Wang, Haotian; Yao, Hongbin; Zheng, Guangyuan; Seh, Zhi Wei; Cai, Qiuxia; Li, Weiyang; Zhou, Guangmin; Zu, Chenxi; Cui, Yi

    2016-04-05

    Lithium-sulfur batteries have attracted attention due to their six-fold specific energy compared with conventional lithium-ion batteries. Dissolution of lithium polysulfides, volume expansion of sulfur and uncontrollable deposition of lithium sulfide are three of the main challenges for this technology. State-of-the-art sulfur cathodes based on metal-oxide nanostructures can suppress the shuttle-effect and enable controlled lithium sulfide deposition. However, a clear mechanistic understanding and corresponding selection criteria for the oxides are still lacking. Herein, various nonconductive metal-oxide nanoparticle-decorated carbon flakes are synthesized via a facile biotemplating method. The cathodes based on magnesium oxide, cerium oxide and lanthanum oxide show enhanced cycling performance. Adsorption experiments and theoretical calculations reveal that polysulfide capture by the oxides is via monolayered chemisorption. Moreover, we show that better surface diffusion leads to higher deposition efficiency of sulfide species on electrodes. Hence, oxide selection is proposed to balance optimization between sulfide-adsorption and diffusion on the oxides.

  2. Balancing surface adsorption and diffusion of lithium-polysulfides on nonconductive oxides for lithium–sulfur battery design

    Science.gov (United States)

    Tao, Xinyong; Wang, Jianguo; Liu, Chong; Wang, Haotian; Yao, Hongbin; Zheng, Guangyuan; Seh, Zhi Wei; Cai, Qiuxia; Li, Weiyang; Zhou, Guangmin; Zu, Chenxi; Cui, Yi

    2016-01-01

    Lithium–sulfur batteries have attracted attention due to their six-fold specific energy compared with conventional lithium-ion batteries. Dissolution of lithium polysulfides, volume expansion of sulfur and uncontrollable deposition of lithium sulfide are three of the main challenges for this technology. State-of-the-art sulfur cathodes based on metal-oxide nanostructures can suppress the shuttle-effect and enable controlled lithium sulfide deposition. However, a clear mechanistic understanding and corresponding selection criteria for the oxides are still lacking. Herein, various nonconductive metal-oxide nanoparticle-decorated carbon flakes are synthesized via a facile biotemplating method. The cathodes based on magnesium oxide, cerium oxide and lanthanum oxide show enhanced cycling performance. Adsorption experiments and theoretical calculations reveal that polysulfide capture by the oxides is via monolayered chemisorption. Moreover, we show that better surface diffusion leads to higher deposition efficiency of sulfide species on electrodes. Hence, oxide selection is proposed to balance optimization between sulfide-adsorption and diffusion on the oxides. PMID:27046216

  3. P-wave velocity test for assessment of geotechnical properties of ...

    Indian Academy of Sciences (India)

    ... modulus of elasticity, water absorption and effective porosity, slake durability index, saturated and dry density of rock using -wave velocity (p). For this purpose geotechnical properties of nine different rock types were determined in the laboratory and their mineralogical composition examined using thin section analysis.

  4. Perinatal management and long-term cardiac outcome in fetal arrhythmia

    NARCIS (Netherlands)

    Hahurij, N.D.; Blom, N.A.; Lopriore, E.; Aziz, M.I.; Nagel, H.T.; Rozendaal, L.; Vandenbussche, F.P.H.A.

    2011-01-01

    BACKGROUND: cardiac arrhythmias are commonly observed in the fetus, however, may have major consequences for fetal development and post natal life. AIMS: to evaluate the perinatal management and cardiac outcome of fetuses with tachy- or bradyarrhythmia. STUDY DESIGN: perinatal management, outcome

  5. Preliminary result of P-wave speed tomography beneath North Sumatera region

    Energy Technology Data Exchange (ETDEWEB)

    Jatnika, Jajat [Earth Science Study Program, Institute of Technology Bandung (Indonesia); Indonesian Meteorological, Climatological and Geophysical Agency (MCGA), Jakarta (Indonesia); Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id [Global Geophysical Research Group, Faculty of Mining and Petroleum Engineering, Insitute of Technology Bandung (Indonesia); Wandono [Indonesian Meteorological, Climatological and Geophysical Agency (MCGA), Jakarta (Indonesia)

    2015-04-24

    The structure of P-wave speed beneath the North Sumatra region was determined using P-wave arrival times compiled by MCGA from time periods of January 2009 to December 2012 combining with PASSCAL data for February to May 1995. In total, there are 2,246 local earthquake events with 10,666 P-wave phases from 63 stations seismic around the study area. Ray tracing to estimate travel time from source to receiver in this study by applying pseudo-bending method while the damped LSQR method was used for the tomographic inversion. Based on assessment of ray coverage, earthquakes and stations distribution, horizontal grid nodes was set up of 30×30 km2 for inside the study area and 80×80 km2 for outside the study area. The tomographic inversion results show low Vp anomaly beneath Toba caldera complex region and around the Sumatra Fault Zones (SFZ). These features are consistent with previous study. The low Vp anomaly beneath Toba caldera complex are observed around Mt. Pusuk Bukit at depths of 5 km down to 100 km. The interpretation is these anomalies may be associated with ascending hot materials from subduction processes at depths of 80 km down to 100 km. The obtained Vp structure from local tomography will give valuable information to enhance understanding of tectonic and volcanic in this study area.

  6. The offset-midpoint traveltime pyramid of P-waves in homogeneous orthorhombic media

    KAUST Repository

    Hao, Qi

    2016-07-18

    The offset-midpoint traveltime pyramid describes the diffraction traveltime of a point diffractor in homogeneous media. We have developed an analytic approximation for the P-wave offset-midpoint traveltime pyramid for homogeneous orthorhombic media. In this approximation, a perturbation method and the Shanks transform were implemented to derive the analytic expressions for the horizontal slowness components of P-waves in orthorhombic media. Numerical examples were shown to analyze the proposed traveltime pyramid formula and determined its accuracy and the application in calculating migration isochrones and reflection traveltime. The proposed offset-midpoint traveltime formula is useful for Kirchhoff prestack time migration and migration velocity analysis for orthorhombic media.

  7. The offset-midpoint traveltime pyramid of P-waves in homogeneous orthorhombic media

    KAUST Repository

    Hao, Qi; Stovas, Alexey; Alkhalifah, Tariq Ali

    2016-01-01

    The offset-midpoint traveltime pyramid describes the diffraction traveltime of a point diffractor in homogeneous media. We have developed an analytic approximation for the P-wave offset-midpoint traveltime pyramid for homogeneous orthorhombic media. In this approximation, a perturbation method and the Shanks transform were implemented to derive the analytic expressions for the horizontal slowness components of P-waves in orthorhombic media. Numerical examples were shown to analyze the proposed traveltime pyramid formula and determined its accuracy and the application in calculating migration isochrones and reflection traveltime. The proposed offset-midpoint traveltime formula is useful for Kirchhoff prestack time migration and migration velocity analysis for orthorhombic media.

  8. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection.

    Science.gov (United States)

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-06-12

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan-Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.

  9. Arctigenin, a Potential Anti-Arrhythmic Agent, Inhibits Aconitine-Induced Arrhythmia by Regulating Multi-Ion Channels

    OpenAIRE

    Zhenying Zhao; Yongqiang Yin; Hong Wu; Min Jiang; Jianshi Lou; Gang Bai; Guo‘an Luo

    2013-01-01

    Background/Aims: Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. Methods: A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were reco...

  10. Features of conngestive heart failure development in patients with post infarct cardiosclerosis concomitant with arrhythmias

    International Nuclear Information System (INIS)

    Zharov, E.I.; Martynov, A.I.; Vertkin, A.L.; Sergeeva, L.I.; Sedov, V.P.

    1989-01-01

    Two hundred and seventy seven patients with coronary heart disease, includng 182 with postinfarction cardiosclerosis undewent 24-hour Holter monitoring. A significant correlation was found between the number of coupled ventricular arrhythmias, ventricular tachycardia paroxysms and developmet of congestive heart failure in patients with postinfarct cardiosclerosis. With evolving metabolic deficiency as evidenced by thallium-201 myocardial scintigraphy, the incidence of congestive heart failure and ventricular arrhythmias increased among the patients

  11. Relativistic corrections to the form factors of Bc into P-wave orbitally excited charmonium

    Science.gov (United States)

    Zhu, Ruilin

    2018-06-01

    We investigated the form factors of the Bc meson into P-wave orbitally excited charmonium using the nonrelativistic QCD effective theory. Through the analytic computation, the next-to-leading order relativistic corrections to the form factors were obtained, and the asymptotic expressions were studied in the infinite bottom quark mass limit. Employing the general form factors, we discussed the exclusive decays of the Bc meson into P-wave orbitally excited charmonium and a light meson. We found that the relativistic corrections lead to a large correction for the form factors, which makes the branching ratios of the decay channels B (Bc ± →χcJ (hc) +π± (K±)) larger. These results are useful for the phenomenological analysis of the Bc meson decays into P-wave charmonium, which shall be tested in the LHCb experiments.

  12. Attenuation of short-period P, PcP, ScP, and pP waves in the earth's mantle

    International Nuclear Information System (INIS)

    Bock, G.; Clements, J.R.

    1982-01-01

    The parameter t* (ratio of body wave travel time to the average quality factor Q) was estimated under various assumptions of the nature of the earthquake sources for short-period P, PcP, and ScP phases originating from earthquakes in the Fiji-Tonga region and recorded at the Warramunga Seismic Array at Tennant Creek (Northern Territory, Australia). Spectral ratios were calculated for the amplitudes of PcP to P and of pP to P. The data reveal a laterally varying Q structure in the Fiji-Tonga region. The high-Q lithosphere descending beneath the Tonga Island arc is overlain above 350 km depth by a wedgelike zone of high attenuation with an average Q/sub α/ between 120 and 200 at short periods. The upper mantle farther to the west of the Tonga island arc is less attenuating, with Q/sub α/, between 370 and 560. Q/sub α/ is about 500 in the upper mantle on the oceanic side of the subduction zone. The t* estimates of this study are much smaller than estimates from the free oscillation model SL8. This can be partly explained by regional variations of Q in the upper mantle. If no lateral Q variations occur in the lower mantle, a frequency-dependent Q can make the PcP and ScP observations consistent with model SL8. Adopting the absorption band model to describe the frequency dependence of Q, the parameter tau 2 , the cut-off period of the high-frequency end of the absorption band, was determined. For different source models with finite corner frequencies, the average tau 2 for the mantle is between 0.01 and 0.10 s (corresponding to frequencies between 16 and 1.6 Hz) as derived from the PcP data, and between 0.06 and 0.12 s (2.7 and 1.3 Hz), as derived from the ScP data

  13. Frequency-tunable terahertz wave generation via excitation of phonon-polaritons in GaP

    CERN Document Server

    Tanabé, T; Nishizawa, J I; Saitô, K; Kimura, T

    2003-01-01

    High-power, wide-frequency-tunable terahertz waves were generated based on difference-frequency generation in GaP crystals with small-angle noncollinear phase matching. The tunable frequency range was as wide as 0.5-7 THz, and the peak power remained high, near 100 mW, over most of the frequency region. The tuning properties were well described by the dispersion relationship for the phonon-polariton mode of GaP up to 6 THz. We measured the spectra of crystal polyethylene and crystal quartz with high resolution using this THz-wave source.

  14. Frequency-tunable terahertz wave generation via excitation of phonon-polaritons in GaP

    International Nuclear Information System (INIS)

    Tanabe, Tadao; Suto, Ken; Nishizawa, Jun-ichi; Saito, Kyosuke; Kimura, Tomoyuki

    2003-01-01

    High-power, wide-frequency-tunable terahertz waves were generated based on difference-frequency generation in GaP crystals with small-angle noncollinear phase matching. The tunable frequency range was as wide as 0.5-7 THz, and the peak power remained high, near 100 mW, over most of the frequency region. The tuning properties were well described by the dispersion relationship for the phonon-polariton mode of GaP up to 6 THz. We measured the spectra of crystal polyethylene and crystal quartz with high resolution using this THz-wave source

  15. Dynamics of skyrmions and edge states in the resistive regime of mesoscopic p-wave superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Fernández Becerra, V., E-mail: VictorLeonardo.FernandezBecerra@uantwerpen.be; Milošević, M.V., E-mail: milorad.milosevic@uantwerpen.be

    2017-02-15

    Highlights: • Voltage–current characterization of a mesoscopic p-wave superconducting sample. • Skyrmions and edge states are stabilized with an out-of-plane applied magnetic field. • In the resistive regime, moving skyrmions and the edge state behave distinctly different from the conventional kinematic vortices. - Abstract: In a mesoscopic sample of a chiral p-wave superconductor, novel states comprising skyrmions and edge states have been stabilized in out-of-plane applied magnetic field. Using the time-dependent Ginzburg–Landau equations we shed light on the dynamic response of such states to an external applied current. Three different regimes are obtained, namely, the superconducting (stationary), resistive (non-stationary) and normal regime, similarly to conventional s-wave superconductors. However, in the resistive regime and depending on the external current, we found that moving skyrmions and the edge state behave distinctly different from the conventional kinematic vortex, thereby providing new fingerprints for identification of p-wave superconductivity.

  16. Reflection of P and SV waves at the free surface of a monoclinic ...

    Indian Academy of Sciences (India)

    The propagation of plane waves in an anisotropic elastic medium possessing monoclinic symmetry is discussed. The expressions for the phase velocity of qP and qSV waves propagating in the plane of elastic symmetry are obtained in terms of the direction cosines of the propagation vector. It is shown that, in general, ...

  17. TECRL, a new life-threatening inherited arrhythmia gene associated with overlapping clinical features of both LQTS and CPVT

    NARCIS (Netherlands)

    Devalla, Harsha D.; Gélinas, Roselle; Aburawi, Elhadi H.; Beqqali, Abdelaziz; Goyette, Philippe; Freund, Christian; Chaix, Marie-A.; Tadros, Rafik; Jiang, Hui; Le Béchec, Antony; Monshouwer-Kloots, Jantine J.; Zwetsloot, Tom; Kosmidis, Georgios; Latour, Frédéric; Alikashani, Azadeh; Hoekstra, Maaike; Schlaepfer, Jurg; Mummery, Christine L.; Stevenson, Brian; Kutalik, Zoltan; de Vries, Antoine Af; Rivard, Léna; Wilde, Arthur Am; Talajic, Mario; Verkerk, Arie O.; Al-Gazali, Lihadh; Rioux, John D.; Bhuiyan, Zahurul A.; Passier, Robert

    2016-01-01

    Genetic causes of many familial arrhythmia syndromes remain elusive. In this study, whole-exome sequencing (WES) was carried out on patients from three different families that presented with life-threatening arrhythmias and high risk of sudden cardiac death (SCD). Two French Canadian probands

  18. The Effect of Raffaelea quercus-mongolicae Inoculations on the Formation of Non-conductive Sapwood of Quercus mongolica.

    Science.gov (United States)

    Torii, Masato; Matsuda, Yosuke; Seo, Sang Tae; Kim, Kyung Hee; Ito, Shin-Ichiro; Moon, Myung Jin; Kim, Seong Hwan; Yamada, Toshihiro

    2014-06-01

    In Korea, mass mortality of Quercus mongolica trees has become obvious since 2004. Raffaelea quercus-mongolicae is believed to be a causal fungus contributing the mortality. To evaluate the pathogenicity of the fungus to the trees, the fungus was multiple- and single-inoculated to the seedlings and twigs of the mature trees, respectively. In both the inoculations, the fungus was reisolated from more than 50% of inoculated twigs and seedlings. In the single inoculations, proportions of the transverse area of non-conductive sapwood at inoculation points and vertical lengths of discoloration expanded from the points were significantly different between the inoculation treatment and the control. In the multiple inoculations, no mortality was confirmed among the seedlings examined. These results showed that R. quercus-mongolicae can colonize sapwood, contribute to sapwood discoloration and disrupt sap flows around inoculation sites of Q. mongolica, although the pathogenicity of the fungus was not proven.

  19. Mortality of Inherited Arrhythmia Syndromes Insight Into Their Natural History

    NARCIS (Netherlands)

    Nannenberg, Eline A.; Sijbrands, Eric J. G.; Dijksman, Lea M.; Alders, Marielle; van Tintelen, J. Peter; Birnie, Martijn; van Langen, Irene M.; Wilde, Arthur A. M.

    Background-For most arrhythmia syndromes, the risk of sudden cardiac death for asymptomatic mutation carriers is ill defined. Data on the natural history of these diseases, therefore, are essential. The family tree mortality ratio method offers the unique possibility to study the natural history at

  20. P-wave dispersion and its relationship to aortic stiffness in patients with acute myocardial infarction after cardiac rehabilitation

    Directory of Open Access Journals (Sweden)

    Rezzan Deniz Acar

    2014-07-01

    Full Text Available BACKGROUND: The aim of our study was to investigate the P-wave dispersion from standard electrocardiograms (ECGs in patients with acute myocardial infarction (AMI after cardiac rehabilitation (CR and determine its relation to arterial stiffness. METHODS: This is a prospective study included 33 patients with AMI and successfully re-vascularized by percutaneous coronary intervention (PCI underwent CR. Left ventricular ejection fraction (LVEF was measured by biplane Simpson’s method. Left atrium (LA volume was calculated. The maximum and minimum durations of P-waves (Pmax and Pmin, respectively were detected, and the difference between Pmax and Pmin was defined as P-wave dispersion (Pd = Pmax–Pmin. Aortic elasticity parameters were measured. RESULTS: LVEF was better after CR. The systolic and diastolic blood pressures decreased after CR, these differences were statistically significant. With exercise training, LA volume decreased significantly. Pmax and Pd values were significantly shorter after the CR program. The maximum and minimum P-waves and P-wave dispersion after CR were 97 ± 6 ms, 53 ± 5 ms, and 44 ± 5 ms, respectively. Aortic strain and distensibility increased and aortic stiffness index was decreased significantly. Aortic stiffness index was 0.4 ± 0.2 versus 0.3 ± 0.2, P = 0.001. Aortic stiffness and left atrial volume showed a moderate positive correlation with P-wave dispersion (r = 0.52, P = 0.005; r = 0.64, P = 0.000, respectively. CONCLUSION: This study showed decreased arterial stiffness indexes in AMI patient’s participated CR, with a significant relationship between the electromechanical properties of the LA that may raise a question of the preventive effect of CR from atrial fibrillation and stroke in patients with acute myocardial infarction.   Keywords: Cardiac Rehabilitation, P-Wave Dispersion, Aortic Stiffness, Acute Myocardial Infarction 

  1. Dispersion durations of P-wave and QT interval in children treated with a ketogenic diet.

    Science.gov (United States)

    Doksöz, Önder; Güzel, Orkide; Yılmaz, Ünsal; Işgüder, Rana; Çeleğen, Kübra; Meşe, Timur

    2014-04-01

    Limited data are available on the effects of a ketogenic diet on dispersion duration of P-wave and QT-interval measures in children. We searched for the changes in these measures with serial electrocardiograms in patients treated with a ketogenic diet. Twenty-five drug-resistant patients with epilepsy treated with a ketogenic diet were enrolled in this study. Electrocardiography was performed in all patients before the beginning and at the sixth month after implementation of the ketogenic diet. Heart rate, maximum and minimum P-wave duration, P-wave dispersion, and maximum and minimum corrected QT interval and QT dispersion were manually measured from the 12-lead surface electrocardiogram. Minimum and maximum corrected QT and QT dispersion measurements showed nonsignificant increase at month 6 compared with baseline values. Other previously mentioned electrocardiogram parameters also showed no significant changes. A ketogenic diet of 6 months' duration has no significant effect on electrocardiogram parameters in children. Further studies with larger samples and longer duration of follow-up are needed to clarify the effects of ketogenic diet on P-wave dispersion and corrected QT and QT dispersion. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. P wave duration and dispersion in patients with hyperthyroidism and the short-term effects of antithyroid treatment.

    Science.gov (United States)

    Guntekin, Unal; Gunes, Yilmaz; Simsek, Hakki; Tuncer, Mustafa; Arslan, Sevket

    2009-09-01

    Prolonged P wave duration and P wave dispersion (PWD) have been associated with an increased risk for atrial fibrillation (AF). Hyperthytodism is a frequent cause of atrial fibrillation (AF). Forty-two patients with newly diagnosed overt hyperthyroidism and 20 healthy people were enrolled in the study. Transthoracic echocardiography, 12 lead surface ECG and thyroid hormone levels were studied at the time of enrollment and after achievement of euthyroid state with propylthiouracil treatment. Maximum P wave duration (Pmax) (97.4+/-14.6 vs. 84.2+/-9.5 msec, phyperthyroid patients compared to control group. Pmax and PWD were significantly correlated with the presence of hyperthyroidism. Pmax (97.4+/-14.6 to 84.3+/-8.6 msec, phyperthyroidism. Diastolic dyfunction was seen in 5 patients at hyperthroid state but only in one patient at euthyroid state. Hyperthyroidism is associated with prolonged P wave duration and dispersion. Achievement of euthyroid state with propylthiouracil treatment results in shortening of P wave variables. Diastolic function may have a partial effect for the increased Pmax and PWD. Shortening of Pmax and PWD may be a marker for the prevention of AF with the anti-thyroid treatment.

  3. P-wave Feshbach resonances of ultracold 6Li

    International Nuclear Information System (INIS)

    Zhang, J.; Kempen, E.G.M. van; Bourdel, T.; Cubizolles, J.; Chevy, F.; Teichmann, M.; Tarruell, L.; Salomon, C.; Khaykovich, L.; Kokkelmans, S.J.J.M.F.

    2004-01-01

    We report the observation of three p-wave Feshbach resonances of 6 Li atoms in the lowest hyperfine state f=1/2. The positions of the resonances are in good agreement with theory. We study the lifetime of the cloud in the vicinity of the Feshbach resonances and show that, depending on the spin states, two- or three-body mechanisms are at play. In the case of dipolar losses, we observe a nontrivial temperature dependence that is well explained by a simple model

  4. An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects.

    Science.gov (United States)

    Kim, Jinkwon; Min, Se Dong; Lee, Myoungho

    2011-06-27

    Numerous studies have been conducted regarding a heartbeat classification algorithm over the past several decades. However, many algorithms have also been studied to acquire robust performance, as biosignals have a large amount of variation among individuals. Various methods have been proposed to reduce the differences coming from personal characteristics, but these expand the differences caused by arrhythmia. In this paper, an arrhythmia classification algorithm using a dedicated wavelet adapted to individual subjects is proposed. We reduced the performance variation using dedicated wavelets, as in the ECG morphologies of the subjects. The proposed algorithm utilizes morphological filtering and a continuous wavelet transform with a dedicated wavelet. A principal component analysis and linear discriminant analysis were utilized to compress the morphological data transformed by the dedicated wavelets. An extreme learning machine was used as a classifier in the proposed algorithm. A performance evaluation was conducted with the MIT-BIH arrhythmia database. The results showed a high sensitivity of 97.51%, specificity of 85.07%, accuracy of 97.94%, and a positive predictive value of 97.26%. The proposed algorithm achieves better accuracy than other state-of-the-art algorithms with no intrasubject between the training and evaluation datasets. And it significantly reduces the amount of intervention needed by physicians.

  5. An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects

    Directory of Open Access Journals (Sweden)

    Min Se Dong

    2011-06-01

    Full Text Available Abstract Background Numerous studies have been conducted regarding a heartbeat classification algorithm over the past several decades. However, many algorithms have also been studied to acquire robust performance, as biosignals have a large amount of variation among individuals. Various methods have been proposed to reduce the differences coming from personal characteristics, but these expand the differences caused by arrhythmia. Methods In this paper, an arrhythmia classification algorithm using a dedicated wavelet adapted to individual subjects is proposed. We reduced the performance variation using dedicated wavelets, as in the ECG morphologies of the subjects. The proposed algorithm utilizes morphological filtering and a continuous wavelet transform with a dedicated wavelet. A principal component analysis and linear discriminant analysis were utilized to compress the morphological data transformed by the dedicated wavelets. An extreme learning machine was used as a classifier in the proposed algorithm. Results A performance evaluation was conducted with the MIT-BIH arrhythmia database. The results showed a high sensitivity of 97.51%, specificity of 85.07%, accuracy of 97.94%, and a positive predictive value of 97.26%. Conclusions The proposed algorithm achieves better accuracy than other state-of-the-art algorithms with no intrasubject between the training and evaluation datasets. And it significantly reduces the amount of intervention needed by physicians.

  6. P-Wave and S-Wave Velocity Structure of Submarine Landslide Associated With Gas Hydrate Layer on Frontal Ridge of Northern Cascadia Margin

    Science.gov (United States)

    He, T.; Lu, H.; Yelisetti, S.; Spence, G.

    2015-12-01

    The submarine landslide associated with gas hydrate is a potential risk for environment and engineering projects, and thus from long time ago it has been a hot topic of hydrate research. The study target is Slipstream submarine landslide, one of the slope failures observed on the frontal ridges of the Northern Cascadia accretionary margin off Vancouver Island. The previous studies indicated a possible connection between this submarine landslide feature and gas hydrate, whose occurrence is indicated by a prominent bottom-simulating reflector (BSR), at a depth of ~265-275 m beneath the seafloor (mbsf). The OBS (Ocean Bottom Seismometer) data collected during SeaJade (Seafloor Earthquake Array - Japan Canada Cascadia Experiment) project were used to derive the subseafloor velocity structure for both P- and S-wave using travel times picked from refraction and reflection events. The P-wave velocity structure above the BSR showed anomalous high velocities of about 2.0 km/s at shallow depths of 100 mbsf, closely matching the estimated depth of the glide plane (100 ± 10 m). Forward modelling of S-waves was carried out using the data from the OBS horizontal components. The S-wave velocities, interpreted in conjunction with the P-wave results, provide the key constraints on the gas hydrate distribution within the pores. The hydrate distribution in the pores is important for determining concentrations, and also for determining the frame strength which is critical for controlling slope stability of steep frontal ridges. The increase in S-wave velocity suggests that the hydrate is distributed as part of the load-bearing matrix to increase the rigidity of the sediment.

  7. Growth of electron plasma waves above and below f(p) in the electron foreshock

    Science.gov (United States)

    Cairns, Iver H.; Fung, Shing F.

    1988-01-01

    This paper investigates the conditions required for electron beams to drive wave growth significantly above and below the electron plasma frequency, f(p), by numerically solving the linear dispersion equation. It is shown that kinetic growth well below f(p) may occur over a broad range of frequencies due to the beam instability, when the electron beam is slow, dilute, and relatively cold. Alternatively, a cold or sharp feature at low parallel velocities in the distribution function may drive kinetic growth significantly below f(p). Kinetic broadband growth significantly above f(p) is explained in terms of faster warmer beams. A unified qualitative theory for the narrow-band and broad-band waves is proposed.

  8. Pure Quasi-P-wave calculation in transversely isotropic media using a hybrid method

    KAUST Repository

    Wu, Zedong

    2018-04-12

    The acoustic approximation for anisotropic media is widely used in current industry imaging and inversion algorithms mainly because P-waves constitute the majority of the energy recorded in seismic exploration. The resulting acoustic formulas tend to be simpler, resulting in more efficient implementations, and depend on fewer medium parameters. However, conventional solutions of the acoustic wave equation with higher-order derivatives suffer from shear wave artifacts. Thus, we derive a new acoustic wave equation for wave propagation in transversely isotropic (TI) media, which is based on a partially separable approximation of the dispersion relation for TI media and free of shear wave artifacts. Even though our resulting equation is not a partial differential equation, it is still a linear equation. Thus, we propose to implement this equation efficiently by combining the finite difference approximation with spectral evaluation of the space-independent parts. The resulting algorithm provides solutions without the constrain of ε ≥ δ. Numerical tests demonstrate the effectiveness of the approach.

  9. Pure Quasi-P-wave calculation in transversely isotropic media using a hybrid method

    KAUST Repository

    Wu, Zedong; Liu, Hongwei; Alkhalifah, Tariq Ali

    2018-01-01

    The acoustic approximation for anisotropic media is widely used in current industry imaging and inversion algorithms mainly because P-waves constitute the majority of the energy recorded in seismic exploration. The resulting acoustic formulas tend to be simpler, resulting in more efficient implementations, and depend on fewer medium parameters. However, conventional solutions of the acoustic wave equation with higher-order derivatives suffer from shear wave artifacts. Thus, we derive a new acoustic wave equation for wave propagation in transversely isotropic (TI) media, which is based on a partially separable approximation of the dispersion relation for TI media and free of shear wave artifacts. Even though our resulting equation is not a partial differential equation, it is still a linear equation. Thus, we propose to implement this equation efficiently by combining the finite difference approximation with spectral evaluation of the space-independent parts. The resulting algorithm provides solutions without the constrain of ε ≥ δ. Numerical tests demonstrate the effectiveness of the approach.

  10. Inhalation of diluted diesel engine emission impacts heart rate variability and arrhythmia occurrence in a rat model of chronic ischemic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Anselme, Frederic [Rouen University Hospital, Service de Cardiologie, Rouen (France); Loriot, Stephane; Henry, Jean-Paul; Thuillez, Christian; Morin, Jean-Paul [University of Rouen France, INSERM U644, School of Medicine-Pharmacy, Rouen, Cedex (France); Dionnet, Frederic [Centre d' Etudes et de Recherches Technologiques en Aerothermique et Moteurs, Saint Etienne du Rouvray (France); Napoleoni, Jean-Gerard [EMKA Technologies, Paris (France)

    2007-04-15

    Both increase in cardiac arrhythmia incidence and decrease in heart rate variability (HRV) have been described following human and experimental animal exposures to air pollutants. However, the potential causal relationship between these two factors remains unclear. Incidence of ventricular arrhythmia and HRV were evaluated during and after a 3 h period of Diesel engine exhaust exposure in ten healthy and ten chronic ischemic heart failure (CHF, 3 months after coronary ligation) Wistar rats using implantable ECG telemetry. Air pollutants were delivered to specifically designed whole body individual exposure chambers at particulate matter concentrations similar to those measured inside cabins of cars inserted in congested urban traffic. Recordings were obtained from unrestraint and unsedated vigil rats. Immediate decrease in RMSSD was observed in both healthy (6.64 {+-} 2.62 vs. 4.89 {+-} 1.67 ms, P < 0.05) and CHF rats (8.01 {+-} 0.89 vs. 6.6 {+-} 1.37 ms, P < 0.05) following exposure. An immediate 200-500% increase in ventricular premature beats was observed in CHF rats only. Whereas HRV progressively returned to baseline values within 2.5 h after exposure start, the proarrhythmic effect persisted as late as 5 h after exposure termination in CHF rats. Persistence of ventricular proarrhythmic effects after HRV normalization suggests that HRV reduction is not the mechanism of cardiac arrhythmias in this model. Our methodological approach, closely reflecting the real clinical situations, appeared to be a unique tool to provide further insight into the pathophysiological mechanisms of traffic related airborne pollution health impact. (orig.)

  11. Constraining spatial variations in P-wave velocity in the upper mantle beneath SE Asia

    NARCIS (Netherlands)

    Li, C.; Hilst, R.D. van der; Toksoz, N.M.

    2006-01-01

    We have produced a P-wave model of the upper mantle beneath Southeast (SE) Asia from reprocessed short period International Seismological Centre (ISC) P and pP data, short period P data of the Annual Bulletin of Chinese Earthquakes (ABCE), and long period PP-P data.We used 3D sensitivity kernels

  12. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  13. Chewing reduces sympathetic nervous response to stress and prevents poststress arrhythmias in rats.

    Science.gov (United States)

    Koizumi, So; Minamisawa, Susumu; Sasaguri, Kenichi; Onozuka, Minoru; Sato, Sadao; Ono, Yumie

    2011-10-01

    Reducing stress is important in preventing sudden death in patients with cardiovascular disease, as stressful events may cause autonomic imbalance and trigger fatal arrhythmias. Since chewing has been shown to inhibit stress-induced neuronal responses in the hypothalamus, we hypothesized that chewing could ameliorate stress-induced autonomic imbalance and prevent arrhythmias. To test this hypothesis, we analyzed changes in radiotelemetered electrocardiograms in rats that were allowed to chew a wooden stick during a 1-h period of immobilization stress. Chewing significantly reduced the occurrence of ventricular premature beats (VPBs) and complex ventricular ectopy after immobilization and prevented stress-induced prolongation of the QT interval of VPBs throughout the 10-h experimental period. It also prevented prolongation of the QRS complex and fluctuations in the QT interval in normal sinus rhythm beats preceding VPBs during both immobilization and in the poststress period. Fast Fourier transform-based spectral analysis of heart-rate variability further showed that chewing significantly inhibited the stress-induced increase in the power ratio of low-to-high frequency activity (LF/HF: a marker of sympathetic activity) during immobilization and in addition was associated with blunting of the stress-induced increase in plasma noradrenaline observed at the termination of immobilization. Similar suppressive effects on the occurrence of VPBs and the LF/HF were observed in rats that were administered the β-adrenergic blocker propranolol before immobilization. These results indicate that chewing can ameliorate sympathetic hyperactivity during stress and prevent poststress arrhythmias and suggest that chewing may provide a nonpharmacological and cost-effective treatment option for patients with a high risk of stress-induced fatal arrhythmia.

  14. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    Directory of Open Access Journals (Sweden)

    Hongqiang Li

    2016-10-01

    Full Text Available Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  15. Design procedure for millimeter-wave InP DHBT stacked power amplifiers

    DEFF Research Database (Denmark)

    Squartecchia, Michele; Johansen, Tom Keinicke; Midili, Virginio

    2015-01-01

    The stacked-transistor concept for power amplifiers (PA) has been investigated in this work. Specifically, this architecture has been applied in the design of millimeter-wave monolithic microwave integrated circuits (MMICs) using indium phosphide (InP) double heterojunction bipolar transistors...

  16. Use of whole exome sequencing for the identification of Ito-based arrhythmia mechanism and therapy.

    Science.gov (United States)

    Sturm, Amy C; Kline, Crystal F; Glynn, Patric; Johnson, Benjamin L; Curran, Jerry; Kilic, Ahmet; Higgins, Robert S D; Binkley, Philip F; Janssen, Paul M L; Weiss, Raul; Raman, Subha V; Fowler, Steven J; Priori, Silvia G; Hund, Thomas J; Carnes, Cynthia A; Mohler, Peter J

    2015-05-26

    Identified genetic variants are insufficient to explain all cases of inherited arrhythmia. We tested whether the integration of whole exome sequencing with well-established clinical, translational, and basic science platforms could provide rapid and novel insight into human arrhythmia pathophysiology and disease treatment. We report a proband with recurrent ventricular fibrillation, resistant to standard therapeutic interventions. Using whole-exome sequencing, we identified a variant in a previously unidentified exon of the dipeptidyl aminopeptidase-like protein-6 (DPP6) gene. This variant is the first identified coding mutation in DPP6 and augments cardiac repolarizing current (Ito) causing pathological changes in Ito and action potential morphology. We designed a therapeutic regimen incorporating dalfampridine to target Ito. Dalfampridine, approved for multiple sclerosis, normalized the ECG and reduced arrhythmia burden in the proband by >90-fold. This was combined with cilostazol to accelerate the heart rate to minimize the reverse-rate dependence of augmented Ito. We describe a novel arrhythmia mechanism and therapeutic approach to ameliorate the disease. Specifically, we identify the first coding variant of DPP6 in human ventricular fibrillation. These findings illustrate the power of genetic approaches for the elucidation and treatment of disease when carefully integrated with clinical and basic/translational research teams. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  17. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  18. The Role of Biologically Active Ingredients from Natural Drug Treatments for Arrhythmias in Different Mechanisms

    OpenAIRE

    Li, Jie; Hu, Dan; Song, Xiaoli; Han, Tao; Gao, Yonghong; Xing, Yanwei

    2017-01-01

    Arrhythmia is a disease that is caused by abnormal electrical activity in the heart rate or rhythm. It is the major cause of cardiovascular morbidity and mortality. Although several antiarrhythmic drugs have been used in clinic for decades, their application is often limited by their adverse effects. As a result, natural drugs, which have fewer side effects, are now being used to treat arrhythmias. We searched for all articles on the role of biologically active ingredients from natural drug t...

  19. Unconventional transport characteristics of p-wave superconducting junctions in Sr2RuO4-Ru eutectic system

    International Nuclear Information System (INIS)

    Kambara, H.; Kashiwaya, S.; Yaguchi, H.; Asano, Y.; Tanaka, Y.; Maeno, Y.

    2010-01-01

    We report on novel local transport characteristics of naturally formed p-wave superconducting junctions of Sr 2 RuO 4 -Ru eutectic system by using microfabrication technique. We observed quite anomalous voltage-current (differential resistance-current) characteristics for both I//ab and I//c directions, which are not seen in conventional Josephson junctions. The anomalous features suggest the internal degrees of freedom of the superconducting state, possibly due to chiral p-wave domain. The dc current acts as a driving force to move chiral p-wave domain walls and form larger critical current path to cause the anomalous hysteresis.

  20. P-wave velocity test for assessment of geotechnical properties of ...

    Indian Academy of Sciences (India)

    Administrator

    P-wave velocity test, a non-destructive and easy method to apply in both field ... ditions, has increasingly been conducted to determine the geotechnical properties of rock materials. .... nent elements in the study area and rich in molds of reed ... Kocabas crystals 5–10 μm in size with no internal architecture ... organic matter.

  1. Design of instantaneous liquid film thickness measurement system for conductive or non-conductive fluid with high viscosity

    Directory of Open Access Journals (Sweden)

    Yongxin Yu

    2017-06-01

    Full Text Available In the paper, a new capacitive sensor with a dielectric film coating was designed to measure the thickness of the liquid film on a flat surface. The measured medium can be conductive or non-conductive fluid with high viscosity such as silicone oil, syrup, CMC solution and melt. With the dielectric film coating, the defects caused by the humidity in a capacitor can be avoided completely. With a excitation frequency 0-20kHz, the static permittivity of capacitive sensor is obtained and stable when small thicknesses are monitored within the frequency of 0-3kHz. Based on the measurement principle, an experimental system was designed and verified including calibration and actual measurement for different liquid film thickness. Experimental results showed that the sensitivity, the resolution, repeatability and linear range of the capacitive sensor are satisfied to the liquid film thickness measurement. Finally, the capacitive measuring system was successfully applied to the water, silicone oil and syrup film thickness measurement.

  2. Comparison of P-wave dispersion in healthy dogs, dogs with chronic valvular disease and dogs with disturbances of supraventricular conduction

    Directory of Open Access Journals (Sweden)

    Nicpoń Józef

    2011-03-01

    Full Text Available Abstract Background P-wave dispersion (Pd is a new ECG index used in human cardiology and veterinary medicine. It is defined as the difference between the maximum and the minimum P-wave duration recorded from multiple different ECG leads. So far no studies were performed assessing the importance of P-wave dispersion in dogs. Methods The current study was aimed at determining proper value of Pd in healthy dogs (group I, dogs with chronic valvular disease (group II and dogs with disturbances of supraventricular conduction (group III. The tests were carried out in 53 healthy dogs, 23 dogs with chronic valvular disease and 12 dogs with disturbances of supraventricular conduction of various breeds, sexes and body weight from 1,5 to 80 kg, aged between 0,5 and 17 years, submitted to the ECG examination. ECG was acquired in dogs in a standing position with BTL SD-8 electrocardiographic device and analyzed once the recording was enlarged. P-wave duration was calculated in 9 ECG leads (I, II, III, aVR, aVL, aVF, V1, V2, V4 from 5 cardiac cycles. Results The proper P-wave dispersion in healthy dogs was determined at up to 24 ms. P-wave dispersion was statistically significant increased (p Conclusions The P-wave dispersion is a constant index in healthy dogs, that is why it can be used for evaluating P wave change in dogs with chronic valvular disease and in dogs with disturbances of supraventricular conduction.

  3. Andrographolide inhibits arrhythmias and is cardioprotective in rabbits

    OpenAIRE

    Zeng, Mengliu; Jiang, Wanzhen; Tian, Youjia; Hao, Jie; Cao, Zhenzhen; Liu, Zhipei; Fu, Chen; Zhang, Peihua; Ma, Jihua

    2017-01-01

    Andrographolide has a protective effect on the cardiovascular system. To study its cardic-electrophysiological effects, action potentials and voltage-gated Na+ (INa), Ca2+ (ICaL), and K+ (IK1, IKr, Ito and IKur) currents were recorded using whole-cell patch clamp and current clamp techniques. Additionally, the effects of andrographolide on aconitine-induced arrhythmias were assessed on electrocardiograms in vivo. We found that andrographolide shortened action potential duration and reduced ma...

  4. Single-Nucleotide Variations in Cardiac Arrhythmias: Prospects for Genomics and Proteomics Based Biomarker Discovery and Diagnostics

    Directory of Open Access Journals (Sweden)

    Ayman Abunimer

    2014-03-01

    Full Text Available Cardiovascular diseases are a large contributor to causes of early death in developed countries. Some of these conditions, such as sudden cardiac death and atrial fibrillation, stem from arrhythmias—a spectrum of conditions with abnormal electrical activity in the heart. Genome-wide association studies can identify single nucleotide variations (SNVs that may predispose individuals to developing acquired forms of arrhythmias. Through manual curation of published genome-wide association studies, we have collected a comprehensive list of 75 SNVs associated with cardiac arrhythmias. Ten of the SNVs result in amino acid changes and can be used in proteomic-based detection methods. In an effort to identify additional non-synonymous mutations that affect the proteome, we analyzed the post-translational modification S-nitrosylation, which is known to affect cardiac arrhythmias. We identified loss of seven known S-nitrosylation sites due to non-synonymous single nucleotide variations (nsSNVs. For predicted nitrosylation sites we found 1429 proteins where the sites are modified due to nsSNV. Analysis of the predicted S-nitrosylation dataset for over- or under-representation (compared to the complete human proteome of pathways and functional elements shows significant statistical over-representation of the blood coagulation pathway. Gene Ontology (GO analysis displays statistically over-represented terms related to muscle contraction, receptor activity, motor activity, cystoskeleton components, and microtubule activity. Through the genomic and proteomic context of SNVs and S-nitrosylation sites presented in this study, researchers can look for variation that can predispose individuals to cardiac arrhythmias. Such attempts to elucidate mechanisms of arrhythmia thereby add yet another useful parameter in predicting susceptibility for cardiac diseases.

  5. Signal-averaged P wave duration and the dimensions of the atria

    DEFF Research Database (Denmark)

    Dixen, Ulrik; Joens, Christian; Rasmussen, Bo V

    2004-01-01

    Delay of atrial electrical conduction measured as prolonged signal-averaged P wave duration (SAPWD) could be due to atrial enlargement. Here, we aimed to compare different atrial size parameters obtained from echocardiography with the SAPWD measured with a signal-averaged electrocardiogram (SAECG)....

  6. Ursodeoxycholic acid prevents ventricular conduction slowing and arrhythmia by restoring T-type calcium current in fetuses during cholestasis

    Science.gov (United States)

    Adeyemi, Oladipupo; Alvarez-Laviada, Anita; Schultz, Francisca; Ibrahim, Effendi; Trauner, Michael; Williamson, Catherine; Glukhov, Alexey V.

    2017-01-01

    Background Increased maternal serum bile acid concentrations in intrahepatic cholestasis of pregnancy (ICP) are associated with fetal cardiac arrhythmias. Ursodeoxycholic acid (UDCA) has been shown to demonstrate anti-arrhythmic properties via preventing ICP-associated cardiac conduction slowing and development of reentrant arrhythmias, although the cellular mechanism is still being elucidated. Methods High-resolution fluorescent optical mapping of electrical activity and electrocardiogram measurements were used to characterize effects of UDCA on one-day-old neonatal and adult female Langendorff-perfused rat hearts. ICP was modelled by perfusion of taurocholic acid (TC, 400μM). Whole-cell calcium currents were recorded from neonatal rat and human fetal cardiomyocytes. Results TC significantly prolonged the PR interval by 11.0±3.5% (P<0.05) and slowed ventricular conduction velocity (CV) by 38.9±5.1% (P<0.05) exclusively in neonatal and not in maternal hearts. A similar CV decline was observed with the selective T-type calcium current (ICa,T) blocker mibefradil 1μM (23.0±6.2%, P<0.05), but not with the L-type calcium current (ICa,L) blocker nifedipine 1μM (6.9±6.6%, NS). The sodium channel blocker lidocaine (30μM) reduced CV by 60.4±4.5% (P<0.05). UDCA co-treatment was protective against CV slowing induced by TC and mibefradil, but not against lidocaine. UDCA prevented the TC-induced reduction in the ICa,T density in both isolated human fetal (−10.2±1.5 versus −5.5±0.9 pA/pF, P<0.05) and neonatal rat ventricular myocytes (−22.3±1.1 versus −9.6±0.8 pA/pF, P<0.0001), whereas UDCA had limited efficacy on the ICa,L. Conclusion Our findings demonstrate that ICa,T plays a significant role in ICP-associated fetal cardiac conduction slowing and arrhythmogenesis, and is an important component of the fetus-specific anti-arrhythmic activity of UDCA. PMID:28934223

  7. Ursodeoxycholic acid prevents ventricular conduction slowing and arrhythmia by restoring T-type calcium current in fetuses during cholestasis.

    Directory of Open Access Journals (Sweden)

    Oladipupo Adeyemi

    Full Text Available Increased maternal serum bile acid concentrations in intrahepatic cholestasis of pregnancy (ICP are associated with fetal cardiac arrhythmias. Ursodeoxycholic acid (UDCA has been shown to demonstrate anti-arrhythmic properties via preventing ICP-associated cardiac conduction slowing and development of reentrant arrhythmias, although the cellular mechanism is still being elucidated.High-resolution fluorescent optical mapping of electrical activity and electrocardiogram measurements were used to characterize effects of UDCA on one-day-old neonatal and adult female Langendorff-perfused rat hearts. ICP was modelled by perfusion of taurocholic acid (TC, 400μM. Whole-cell calcium currents were recorded from neonatal rat and human fetal cardiomyocytes.TC significantly prolonged the PR interval by 11.0±3.5% (P<0.05 and slowed ventricular conduction velocity (CV by 38.9±5.1% (P<0.05 exclusively in neonatal and not in maternal hearts. A similar CV decline was observed with the selective T-type calcium current (ICa,T blocker mibefradil 1μM (23.0±6.2%, P<0.05, but not with the L-type calcium current (ICa,L blocker nifedipine 1μM (6.9±6.6%, NS. The sodium channel blocker lidocaine (30μM reduced CV by 60.4±4.5% (P<0.05. UDCA co-treatment was protective against CV slowing induced by TC and mibefradil, but not against lidocaine. UDCA prevented the TC-induced reduction in the ICa,T density in both isolated human fetal (-10.2±1.5 versus -5.5±0.9 pA/pF, P<0.05 and neonatal rat ventricular myocytes (-22.3±1.1 versus -9.6±0.8 pA/pF, P<0.0001, whereas UDCA had limited efficacy on the ICa,L.Our findings demonstrate that ICa,T plays a significant role in ICP-associated fetal cardiac conduction slowing and arrhythmogenesis, and is an important component of the fetus-specific anti-arrhythmic activity of UDCA.

  8. Cardiac arrhythmia beat classification using DOST and PSO tuned SVM.

    Science.gov (United States)

    Raj, Sandeep; Ray, Kailash Chandra; Shankar, Om

    2016-11-01

    The increase in the number of deaths due to cardiovascular diseases (CVDs) has gained significant attention from the study of electrocardiogram (ECG) signals. These ECG signals are studied by the experienced cardiologist for accurate and proper diagnosis, but it becomes difficult and time-consuming for long-term recordings. Various signal processing techniques are studied to analyze the ECG signal, but they bear limitations due to the non-stationary behavior of ECG signals. Hence, this study aims to improve the classification accuracy rate and provide an automated diagnostic solution for the detection of cardiac arrhythmias. The proposed methodology consists of four stages, i.e. filtering, R-peak detection, feature extraction and classification stages. In this study, Wavelet based approach is used to filter the raw ECG signal, whereas Pan-Tompkins algorithm is used for detecting the R-peak inside the ECG signal. In the feature extraction stage, discrete orthogonal Stockwell transform (DOST) approach is presented for an efficient time-frequency representation (i.e. morphological descriptors) of a time domain signal and retains the absolute phase information to distinguish the various non-stationary behavior ECG signals. Moreover, these morphological descriptors are further reduced in lower dimensional space by using principal component analysis and combined with the dynamic features (i.e based on RR-interval of the ECG signals) of the input signal. This combination of two different kinds of descriptors represents each feature set of an input signal that is utilized for classification into subsequent categories by employing PSO tuned support vector machines (SVM). The proposed methodology is validated on the baseline MIT-BIH arrhythmia database and evaluated under two assessment schemes, yielding an improved overall accuracy of 99.18% for sixteen classes in the category-based and 89.10% for five classes (mapped according to AAMI standard) in the patient

  9. Comparison of real-time classification systems for arrhythmia detection on Android-based mobile devices.

    Science.gov (United States)

    Leutheuser, Heike; Gradl, Stefan; Kugler, Patrick; Anneken, Lars; Arnold, Martin; Achenbach, Stephan; Eskofier, Bjoern M

    2014-01-01

    The electrocardiogram (ECG) is a key diagnostic tool in heart disease and may serve to detect ischemia, arrhythmias, and other conditions. Automatic, low cost monitoring of the ECG signal could be used to provide instantaneous analysis in case of symptoms and may trigger the presentation to the emergency department. Currently, since mobile devices (smartphones, tablets) are an integral part of daily life, they could form an ideal basis for automatic and low cost monitoring solution of the ECG signal. In this work, we aim for a realtime classification system for arrhythmia detection that is able to run on Android-based mobile devices. Our analysis is based on 70% of the MIT-BIH Arrhythmia and on 70% of the MIT-BIH Supraventricular Arrhythmia databases. The remaining 30% are reserved for the final evaluation. We detected the R-peaks with a QRS detection algorithm and based on the detected R-peaks, we calculated 16 features (statistical, heartbeat, and template-based). With these features and four different feature subsets we trained 8 classifiers using the Embedded Classification Software Toolbox (ECST) and compared the computational costs for each classification decision and the memory demand for each classifier. We conclude that the C4.5 classifier is best for our two-class classification problem (distinction of normal and abnormal heartbeats) with an accuracy of 91.6%. This classifier still needs a detailed feature selection evaluation. Our next steps are implementing the C4.5 classifier for Android-based mobile devices and evaluating the final system using the remaining 30% of the two used databases.

  10. Monitoring of arrhythmia and sudden death in a hemodialysis population: The CRASH-ILR Study.

    Directory of Open Access Journals (Sweden)

    Paul R Roberts

    Full Text Available It has been suggested that sudden cardiac death (SCD contributes around 50% of cardiovascular and 27% of all-cause mortality in hemodialysis patients. The true burden of arrhythmias and arrhythmic deaths in this population, however, remains poorly characterised. Cardio Renal Arrhythmia Study in Hemodialysis (CRASH-ILR is a prospective, implantable loop recorder single centre study of 30 established hemodialysis patients and one of the first to provide long-term ambulatory ECG monitoring.30 patients (60% male aged 68±12 years receiving hemodialysis for 45±40 months with varied etiology (diabetes 37%, hypertension 23% and left ventricular ejection fraction (LVEF 55±8% received a Reveal XT implantable loop recorder (Medtronic, USA between August 2011 and October 2014. ECG data from loop recorders were transmitted at each hemodialysis session using a remote monitoring system. Primary outcome was SCD or implantation of a (tachy or bradyarrhythmia controlling device and secondary outcome, the development of arrhythmia necessitating medical intervention.During 379,512 hours of continuous ECG monitoring (mean 12,648±9,024 hours/patient, there were 8 deaths-2 SCD and 6 due to generalised deterioration/sepsis. 5 (20% patients had a primary outcome event (2 SCD, 3 pacemaker implantations for bradyarrhythmia. 10 (33% patients reached an arrhythmic primary or secondary end point. Median event free survival for any arrhythmia was 2.6 years (95% confidence intervals 1.6-3.6 years.The findings confirm the high mortality rate seen in hemodialysis populations and contrary to initial expectations, bradyarrhythmias emerged as a common and potentially significant arrhythmic event.

  11. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.

    Science.gov (United States)

    Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando

    2016-04-01

    Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.

  12. Holographic p-wave superconductor with disorder

    International Nuclear Information System (INIS)

    Areán, D.; Farahi, A.; Zayas, L.A. Pando; Landea, I. Salazar; Scardicchio, A.

    2015-01-01

    We implement the effects of disorder on a holographic p-wave superconductor by introducing a random chemical potential which defines the local energy of the charge carriers. Since there are various possibilities for the orientation of the vector order parameter, we explore the behavior of the condensate in the parallel and perpendicular directions to the introduced disorder. We clarify the nature of various branches representing competing solutions and construct the disordered phase diagram. We find that moderate disorder enhances superconductivity as determined by the value of the condensate. Though we mostly focus on uncorrelated noise, we also consider a disorder characterized by its spectral properties and study in detail its influence on the spectral properties of the condensate and charge density. We find fairly universal responses of the resulting power spectra characterized by linear functions of the disorder power spectrum.

  13. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection †

    Science.gov (United States)

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-01-01

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities. PMID:28604628

  14. Arrhythmia as a cardiac manifestation in MELAS syndrome.

    Science.gov (United States)

    Thomas, Tamara; Craigen, William J; Moore, Ryan; Czosek, Richard; Jefferies, John L

    2015-09-01

    A 44-year-old female with a diagnosis of mitochondrial myopathy, encephalopathy and stroke-like episodes (MELAS) syndrome had progressive left ventricular hypertrophy (LVH) on echocardiogram. A Holter monitor demonstrated episodes of non-sustained atrial tachycardia, a finding not been previously described in this population. This unique case of MELAS syndrome demonstrates the known associated cardiac manifestation of LVH and the new finding of atrial tachycardia which may represent the potential for subclinical arrhythmia in this population.

  15. Fast Moment Magnitude Determination from P-wave Trains for Bucharest Rapid Early Warning System (BREWS)

    Science.gov (United States)

    Lizurek, Grzegorz; Marmureanu, Alexandru; Wiszniowski, Jan

    2017-03-01

    Bucharest, with a population of approximately 2 million people, has suffered damage from earthquakes in the Vrancea seismic zone, which is located about 170 km from Bucharest, at a depth of 80-200 km. Consequently, an earthquake early warning system (Bucharest Rapid earthquake Early Warning System or BREWS) was constructed to provide some warning about impending shaking from large earthquakes in the Vrancea zone. In order to provide quick estimates of magnitude, seismic moment was first determined from P-waves and then a moment magnitude was determined from the moment. However, this magnitude may not be consistent with previous estimates of magnitude from the Romanian Seismic Network. This paper introduces the algorithm using P-wave spectral levels and compares them with catalog estimates. The testing procedure used waveforms from about 90 events with catalog magnitudes from 3.5 to 5.4. Corrections to the P-wave determined magnitudes according to dominant intermediate depth events mechanism were tested for November 22, 2014, M5.6 and October 17, M6 events. The corrections worked well, but unveiled overestimation of the average magnitude result of about 0.2 magnitude unit in the case of shallow depth event ( H < 60 km). The P-wave spectral approach allows for the relatively fast estimates of magnitude for use in BREWS. The average correction taking into account the most common focal mechanism for radiation pattern coefficient may lead to overestimation of the magnitude for shallow events of about 0.2 magnitude unit. However, in case of events of intermediate depth of M6 the resulting M w is underestimated at about 0.1-0.2. We conclude that our P-wave spectral approach is sufficiently robust for the needs of BREWS for both shallow and intermediate depth events.

  16. The effect of intermittent fasting and water restriction on myocardial ischemia/reperfusion-induced arrhythmia in rats

    OpenAIRE

    KAYA, Salih Tunç; BOZDOĞAN, Ömer

    2011-01-01

    To investigate the effect of intermittent fasting and water restriction on ischemia/reperfusion-induced arrhythmias. Materials and methods: Six minutes of ischemia followed by 6 min of reperfusion was produced by the ligation and then releasing of the left coronary artery. Intermittent fasting and water restriction were applied during 1 month for 12 h/day. The duration, type, and incidence of arrhythmias during reperfusion and the survival rate at the end of reperfusion were determined and c...

  17. LiteNet: Lightweight Neural Network for Detecting Arrhythmias at Resource-Constrained Mobile Devices

    Directory of Open Access Journals (Sweden)

    Ziyang He

    2018-04-01

    Full Text Available By running applications and services closer to the user, edge processing provides many advantages, such as short response time and reduced network traffic. Deep-learning based algorithms provide significantly better performances than traditional algorithms in many fields but demand more resources, such as higher computational power and more memory. Hence, designing deep learning algorithms that are more suitable for resource-constrained mobile devices is vital. In this paper, we build a lightweight neural network, termed LiteNet which uses a deep learning algorithm design to diagnose arrhythmias, as an example to show how we design deep learning schemes for resource-constrained mobile devices. Compare to other deep learning models with an equivalent accuracy, LiteNet has several advantages. It requires less memory, incurs lower computational cost, and is more feasible for deployment on resource-constrained mobile devices. It can be trained faster than other neural network algorithms and requires less communication across different processing units during distributed training. It uses filters of heterogeneous size in a convolutional layer, which contributes to the generation of various feature maps. The algorithm was tested using the MIT-BIH electrocardiogram (ECG arrhythmia database; the results showed that LiteNet outperforms comparable schemes in diagnosing arrhythmias, and in its feasibility for use at the mobile devices.

  18. Obesity and exercise-induced ectopic ventricular arrhythmias in apparently healthy middle aged adults.

    Science.gov (United States)

    Sabbag, Avi; Sidi, Yechezkel; Kivity, Shaye; Beinart, Roy; Glikson, Michael; Segev, Shlomo; Goldenberg, Ilan; Maor, Elad

    2016-03-01

    Obesity and overweight are strongly associated with cardiovascular morbidity and mortality. However, there are limited data on the association between excess weight and the risk of ectopic ventricular activity. We investigated the association between body mass index (BMI) and the risk for ectopic ventricular activity (defined as multiple ventricular premature beats (≥3), ventricular bigeminy, nonsustained ventricular tachycardia or sustained ventricular tachycardia) during exercise stress testing among 22,516 apparently healthy men and women who attended periodic health screening examinations between the years 2000 and 2014. All subjects had completed maximal exercise stress testing annually according to the Bruce protocol. Subjects were divided at baseline into three groups: normal weight (BMI ≥ 18.5 kg/m(2) andexercise-induced ectopic ventricular activity arrhythmias was highest among obese subjects, intermediate among overweight subjects and lowest among subjects with normal weight (3.4%, 2.7% and 2.2% respectively; p exercise compared with subjects with normal weight (p = 0.005), and that each 1 kg/m(2) increase in BMI was associated with a significant 4% (p = 0.002) increased adjusted risk for exercise-induced ventricular arrhythmias. Obesity is independently associated with increased likelihood of ectopic ventricular arrhythmia during exercise. © The European Society of Cardiology 2015.

  19. LiteNet: Lightweight Neural Network for Detecting Arrhythmias at Resource-Constrained Mobile Devices.

    Science.gov (United States)

    He, Ziyang; Zhang, Xiaoqing; Cao, Yangjie; Liu, Zhi; Zhang, Bo; Wang, Xiaoyan

    2018-04-17

    By running applications and services closer to the user, edge processing provides many advantages, such as short response time and reduced network traffic. Deep-learning based algorithms provide significantly better performances than traditional algorithms in many fields but demand more resources, such as higher computational power and more memory. Hence, designing deep learning algorithms that are more suitable for resource-constrained mobile devices is vital. In this paper, we build a lightweight neural network, termed LiteNet which uses a deep learning algorithm design to diagnose arrhythmias, as an example to show how we design deep learning schemes for resource-constrained mobile devices. Compare to other deep learning models with an equivalent accuracy, LiteNet has several advantages. It requires less memory, incurs lower computational cost, and is more feasible for deployment on resource-constrained mobile devices. It can be trained faster than other neural network algorithms and requires less communication across different processing units during distributed training. It uses filters of heterogeneous size in a convolutional layer, which contributes to the generation of various feature maps. The algorithm was tested using the MIT-BIH electrocardiogram (ECG) arrhythmia database; the results showed that LiteNet outperforms comparable schemes in diagnosing arrhythmias, and in its feasibility for use at the mobile devices.

  20. Effektmålinger på Wave Star i Nissum Bredning

    DEFF Research Database (Denmark)

    Frigaard, Peter; Andersen, Thomas Lykke

    Wave Star test-maskinen i Nissum Bredning blev sat i kontinuerlig drift den 24. juli 2006. Igennem de seneste 2½ år er den producerede effekt blevet målt kontinuert og kun med mindre afbrydelser. Målingerne dækker over drift på alle årstiderne (forår, sommer, efterår, vinter) i et meget omskiftel...

  1. An extended family suddenly confronted with a life-threatening hereditary arrhythmia

    NARCIS (Netherlands)

    Hendriks, K.S.W.H.; Van Langen, I.M.; Van Tintelen, J.P.; Grosfeld, F.J.M.; Wilde, A.A.M.; Ten Kroode, H.F.J.

    2005-01-01

    Objective. This exploratory study serves to illustrate the psychological impact on an extended family in the process of genetic counselling and testing for a potentially life-threatening arrhythmia, the long-QT syndrome (LQTS). Method. All members of the third generation and their partners (n=11)

  2. Cardiovascular exercise and burden of arrhythmia in patients with atrial fibrillation

    DEFF Research Database (Denmark)

    Skielboe, Ane Katrine; Bandholm, Thomas Quaade; Hakmann, Stine

    2017-01-01

    BACKGROUND: Physical activity at moderate-high intensity is recommended to prevent lifestyle diseases. Patients with atrial fibrillation are at risk of a sedentary lifestyle due to fear of exercise-induced episodes of atrial fibrillation. The burden of arrhythmia can be reduced by physical exercise...

  3. P Wave Duration And Dispersion In Patients With Hyperthyroidism And The Short-term Effects Of Antithyroid Treatment

    Directory of Open Access Journals (Sweden)

    Unal Guntekin

    2009-09-01

    Full Text Available Background: Prolonged P wave duration and P wave dispersion (PWD have been associated with an increased risk for atrial fibrillation (AF. Hyperthytodism is a frequent cause of atrial fibrillation (AF. Methods: Forty-two patients with newly diagnosed overt hyperthyroidism and 20 healthy people were enrolled in the study. Transthoracic echocardiography, 12 lead surface ECG and thyroid hormone levels were studied at the time of enrollment and after achievement of euthyroid state with propylthiouracil treatment. Results: Maximum P wave duration (Pmax (97.4±14.6 vs. 84.2±9.5 msec, p<0.001, PWD (42.9±10.7 vs. 31.0±6.2 msec, p<0.001, deceleration (DT (190.7±22.6 vs. 177.0±10.2 msec, p=0.013 and isovolumetric relaxation times (IVRT (90.9±11.2 vs. 79.6±10.5 msec, p<0.001 were significantly higher in hyperthyroid patients compared to control group. Pmax and PWD were significantly correlated with the presence of hyperthyroidism. Pmax (97.4±14.6 to 84.3±8.6 msec, p<0,001 Pmin (54.1±8.6 to 48.1±8.5 msec, p=0.002, PWD (42.9±10.7 to 35.9±8.1 msec, p=0.002 and DT (190.7±22.6 to 185.5±18.3, p=0.036 were significantly decreased after achievement of euthyroid state in patients with hyperthyroidism. Diastolic dyfunction was seen in 5 patients at hyperthroid state but only in one patient at euthyroid state. Conclusions: Hyperthyroidism is associated with prolonged P wave duration and dispersion. Achievement of euthyroid state with propylthiouracil treatment results in shortening of P wave variables. Diastolic function may have a partial effect for the increased Pmax and PWD. Shortening of Pmax and PWD may be a marker for the prevention of AF with the anti-thyroid treatment.

  4. Elastic pion-nucleon P-wave scattering in soliton models

    International Nuclear Information System (INIS)

    Holzwarth, G.

    1990-01-01

    The equivalence of low-energy P-wave πN scattering in soliton models with the well-established Δ-isobar model is shown to hold even if all constraints on redundant collective variables are ignored. This provides strong support for the unusual (time-derivative) form of meson-baryon coupling in such models, and for the expectation that the soliton description of πN-scattering can be reliably extended down to pion threshold energies in a technically simple way. (orig.)

  5. Arrhythmias and hemodialysis: role of potassium and new diagnostic tools.

    Science.gov (United States)

    Buemi, Michele; Coppolino, Giuseppe; Bolignano, Davide; Sturiale, Alessio; Campo, Susanna; Buemi, Antoine; Crascì, Eleonora; Romeo, Adolfo

    2009-01-01

    Cardiovascular diseases represent the main causes of death in patients affected by renal failure, and arrhythmias are frequently observed in patients undergoing hemodialysis. Dialytic treatment per se can be considered as an arrhythmogenic stimulus; moreover, uraemic patients are characterized by a "pro-arrhythmic substrate" because of the high prevalence of ischaemic heart disease, left ventricular hypertrophy and autonomic neuropathy. One of the most important pathogenetic element involved in the onset of intra-dialytic arrhythmias is the alteration in electrolytes concentration, particularly calcium and potassium. It may be very useful to monitor the patient's cardiac activity during the whole hemodilaytic session. Nevertheless, the application of an extended intradialytic electrocardiographic monitoring is not simple because of several technical and structural impairments. We tried to overcome these difficulties using Whealthy, a wearable system consisting in a t-shirt composed of conductors and piezoresistive materials, integrated to form fibers and threads connected to tissutal sensors, electrodes, and connectors. ECG and pneumographic impedance signals are acquired by the electrodes in the tissue, and the data are registered by a small computer and transmitted via GPRS or Bluetooth.

  6. ECG-based 4D-dose reconstruction of cardiac arrhythmia ablation with carbon ion beams: application in a porcine model

    Science.gov (United States)

    Richter, Daniel; Immo Lehmann, H.; Eichhorn, Anna; Constantinescu, Anna M.; Kaderka, Robert; Prall, Matthias; Lugenbiel, Patrick; Takami, Mitsuru; Thomas, Dierk; Bert, Christoph; Durante, Marco; Packer, Douglas L.; Graeff, Christian

    2017-09-01

    Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R-R interval. 4D-dose calculation was performed using GSI’s in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage (D95 and V95), heterogeneity (HI  =  D5-D95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.

  7. Testing T-odd, p-even interactions with gamma-rays from neutron p-wave resonances

    International Nuclear Information System (INIS)

    Barabanov, A.L.

    1992-01-01

    A new method for the study of time reversal violation is described. It consists of measurements of the forward-backward asymmetry in individual gamma-ray transitions resulting from unpolarized neutron capture in p-wave resonance. An experiment with a 113 Cd target performed at the Dubna pulsed neutron source has been analyzed and a limit on the time reversal odd, parity even interaction extracted. The possibilities of experiments using the powerful pulsed neutron source at Los Alamos are considered. 23 refs.; 2 figs

  8. Acoustic VTI wavefield tomography of P-wave surface and VSP data

    KAUST Repository

    Li, Vladimir

    2017-08-17

    Transversely isotropic (TI) models have become standard in depth imaging and are often used in waveform inversion. Here, we develop a robust wave-equation-based tomographic algorithm for building acoustic VTI (transversely isotropic with a vertical symmetry axis) velocity models from P-wave surface reflection and vertical seismic profiling (VSP) data. Wavefield extrapolation is performed with an integral operator to avoid generating shear-wave artifacts. Focusing energy in extended images produced by reverse-time migration (RTM) makes it possible to update the zero-dip NMO velocity Vnmo and the anellipiticity parameter η. To constrain the anisotropy coefficient δ and improve the accuracy in Vnmo and η, we employ borehole information by introducing an additional objective-function term designed to fit VSP data. Image-guided smoothing is applied to both data- and image-domain gradients to steer the inversion towards geologically plausible solutions. Testing on the VTI Marmousi model shows that the joint inversion of surface and VSP data helps estimate all three relevant medium parameters.

  9. Acoustic VTI wavefield tomography of P-wave surface and VSP data

    KAUST Repository

    Li, Vladimir; Tsvankin, Ilya; Guitton, Antoine; Alkhalifah, Tariq Ali

    2017-01-01

    Transversely isotropic (TI) models have become standard in depth imaging and are often used in waveform inversion. Here, we develop a robust wave-equation-based tomographic algorithm for building acoustic VTI (transversely isotropic with a vertical symmetry axis) velocity models from P-wave surface reflection and vertical seismic profiling (VSP) data. Wavefield extrapolation is performed with an integral operator to avoid generating shear-wave artifacts. Focusing energy in extended images produced by reverse-time migration (RTM) makes it possible to update the zero-dip NMO velocity Vnmo and the anellipiticity parameter η. To constrain the anisotropy coefficient δ and improve the accuracy in Vnmo and η, we employ borehole information by introducing an additional objective-function term designed to fit VSP data. Image-guided smoothing is applied to both data- and image-domain gradients to steer the inversion towards geologically plausible solutions. Testing on the VTI Marmousi model shows that the joint inversion of surface and VSP data helps estimate all three relevant medium parameters.

  10. Data on the electromagnetic pion form factor and p-wave

    International Nuclear Information System (INIS)

    Dubnicka, S.; Meshcheryakov, V.A.; Milko, J.

    1980-01-01

    The pion form factor absolute value data (free of the omega meson contribution) are unified with the P-wave isovector ππ phase shift. The resultant real and imaginary parts of the pion form factor are described by means of the Pade approximation. All the data, which involve the pion form factor experimental points from the range of momenta - 0.8432 GeV 2 2 , the pion charge radius, and the P-wave isovector ππ phase shift in the elastic region (including also the generally accepted value of the scattering length) are mutually consistent. The data themselves through the Pade approximation reveal that the aforementioned consistency can be achieved only if the pion form factor left-hand cut from the second Riemann sheet is taken into account. Almost in all of the considered Pade approximations one stable pion form factor zero is found in the space-like region, which might indicate the existence of a diffraction minimum in the differential cross section for elastic e - π scattering as a consequence of the constituent structure of the pion like in the case of the electron elastic scattering on nuclei

  11. An extended family suddenly confronted with a life-threatening hereditary arrhythmia

    NARCIS (Netherlands)

    Hendriks, K. S. W. H.; van Langen, I. M.; van Tintelen, J. P.; Grosfeld, F. J. M.; Wilde, A. A. M.; ten Kroode, H. F. J.

    2005-01-01

    This exploratory study serves to illustrate the psychological impact on an extended family in the process of genetic counselling and testing for a potentially life-threatening arrhythmia, the long-QT syndrome (LQTS). All members of the third generation and their partners (n=11) were interviewed, the

  12. N-3 fatty acids from fish and markers of cardiac arrhythmia

    NARCIS (Netherlands)

    Geelen, A.

    2004-01-01

    N‑3 fatty acids from fish may protect against heart disease mortality by preventing fatal arrhythmias. The objective of this thesis was to investigate whether this possible antiarrhythmic effect of n-3 fatty acids is supported by short-term effects on electrophysiological markers. We performed two

  13. The influence of type 2 diabetes mellitus on the frequency and complexity of ventricular arrhythmias and heart rate variability in patients after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Stoičkov Viktor

    2016-01-01

    Full Text Available Background/Aim. After myocardial infarction arrhythmic cardiac deaths are significantly more frequent compared to non-arrhythmic ones. The aim of the study was to investigate the influence of type 2 diabetes mellitus (T2DM on the frequency and complexity of ventricular arrhythmias after myocardial infarction. Methods. The study included 293 patients, mean age 59.5 ± 9.21 years, who were at least six months after acute myocardial infarction with the sinus rhythm, without atrioventricular blocks and branch blocks. In the clinical group 95 (32.42% patients were with T2DM, while 198 (67.57% patients were without diabetes. All of the patients were subjected to the following procedures: standard ECG according to which the corrected QT dispersion (QTdc was calculated, exercise stress test, and 24-hour holter monitoring according to which, the four parameters of time domain of heart rate variability (HRV were analyzed: standard deviation of all normal RR intervals during 24 hours (SDNN, standard deviation of the averages of normal RR intervals in all five-minute segments during 24 hours (SDANN, the square root of the mean of the sum of the squares of differences between adjacent normal (RMS-SD, and percentage of consequtive RR intervals which differed for more than 50 ms during 24 hours (NN > 50 ms. Results. In patients after myocardial infarction, patients with T2DM had significantly higher percentage of frequent and complex ventricular arrhythmias compared to the patients without diabetes (p 50 ms (p < 0.001, and significantly higher values of QTdc (p < 0.001 compared to the patients without diabetes. Conclusion. The study showed that type 2 diabetes mellitus has significant influence on ventricular arrhythmias, HRV parameters and QT dispersion in patients after myocardial infarction.

  14. The Role of Biologically Active Ingredients from Natural Drug Treatments for Arrhythmias in Different Mechanisms.

    Science.gov (United States)

    Li, Jie; Hu, Dan; Song, Xiaoli; Han, Tao; Gao, Yonghong; Xing, Yanwei

    2017-01-01

    Arrhythmia is a disease that is caused by abnormal electrical activity in the heart rate or rhythm. It is the major cause of cardiovascular morbidity and mortality. Although several antiarrhythmic drugs have been used in clinic for decades, their application is often limited by their adverse effects. As a result, natural drugs, which have fewer side effects, are now being used to treat arrhythmias. We searched for all articles on the role of biologically active ingredients from natural drug treatments for arrhythmias in different mechanisms in PubMed. This study reviews 19 natural drug therapies, with 18 active ingredient therapies, such as alkaloids, flavonoids, saponins, quinones, and terpenes, and two kinds of traditional Chinese medicine compound (Wenxin-Keli and Shensongyangxin), all of which have been studied and reported as having antiarrhythmic effects. The primary focus is the proposed antiarrhythmic mechanism of each natural drug agent. Conclusion . We stress persistent vigilance on the part of the provider in discussing the use of natural drug agents to provide a solid theoretical foundation for further research on antiarrhythmia drugs.

  15. Travelling wave solutions to the K-P-P equation at supercritical wave speeds: a parallel to Simon Harris' probabilistic analysis

    NARCIS (Netherlands)

    Kyprianou, A.E.

    2000-01-01

    Recently Harris using probabilistic methods alone has given new proofs for the known existence asymptotics and unique ness of travelling wave solutions to the KPP equation Following in this vein we outline alternative probabilistic proofs for wave speeds exceeding the critical minimal wave speed

  16. Molecular components in P-wave charmed-strange mesons

    CERN Document Server

    Ortega, Pablo G.

    2016-10-26

    Results obtained by various experiments show that the $D_{s0}^{\\ast}(2317)$ and $D_{s1}(2460)$ mesons are very narrow states located below the $DK$ and $D^{\\ast}K$ thresholds, respectively. This is markedly in contrast with the expectations of naive quark models and heavy quark symmetry. Motivated by a recent lattice study which addresses the mass shifts of the $c\\bar{s}$ ground states with quantum numbers $J^{P}=0^{+}$ ($D_{s0}^{\\ast}(2317)$) and $J^{P}=1^{+}$ ($D_{s1}(2460)$) due to their coupling with $S$-wave $D^{(\\ast)}K$ thresholds, we perform a similar analysis within a nonrelativistic constituent quark model in which quark-antiquark and meson-meson degrees of freedom are incorporated. The quark model has been applied to a wide range of hadronic observables and thus the model parameters are completely constrained. The coupling between quark-antiquark and meson-meson Fock components is done using a modified version of the $^{3}P_{0}$ decay model. We observe that the coupling of the $0^{+}$ $(1^{+})$ mes...

  17. Diazonium-functionalized thin films from the spontaneous reaction of p-phenylenebis(diazonium) salts

    OpenAIRE

    Marshall, Nicholas; Rodriguez, Andres; Crittenden, Scott

    2018-01-01

    Salts of the diazonium coupling agent p-phenylenebis(diazonium) form diazonium-terminated conjugated thin films on a variety of conductive and nonconductive surfaces by spontaneous reaction of the coupling agent with the surface. The resulting diazonium-bearing surface can be reacted with various organic and inorganic nucleophiles to form a functionalized surface. These surfaces have been characterized with voltammetry, XPS, infrared and Raman spectroscopy, and atomic force microscopy. Substr...

  18. Ion Channel Trafficking: Control of Ion Channel Density as a Target for Arrhythmias?

    Directory of Open Access Journals (Sweden)

    Elise Balse

    2017-10-01

    Full Text Available The shape of the cardiac action potential (AP is determined by the contributions of numerous ion channels. Any dysfunction in the proper function or expression of these ion channels can result in a change in effective refractory period (ERP and lead to arrhythmia. The processes underlying the correct targeting of ion channels to the plasma membrane are complex, and have not been fully characterized in cardiac myocytes. Emerging evidence highlights ion channel trafficking as a potential causative factor in certain acquired and inherited arrhythmias, and therapies which target trafficking as opposed to pore block are starting to receive attention. In this review we present the current evidence for the mechanisms which underlie precise control of cardiac ion channel trafficking and targeting.

  19. Recommendations regarding dietary intake and caffeine and alcohol consumption in patients with cardiac arrhythmias: what do you tell your patients to do or not to do?

    Science.gov (United States)

    Glatter, Kathryn A; Myers, Richard; Chiamvimonvat, Nipavan

    2012-10-01

    The etiology of arrhythmias including atrial fibrillation is multifactorial. Most arrhythmias are associated with comorbid illnesses like hypertension, diabetes, thyroid disease, or advanced age. Although it is tempting to blame a stimulant like caffeine as a trigger for arrhythmias, the literature does not support this idea. There is no real benefit to having patients with arrhythmias limit their caffeine intake. Caffeine is a vasoactive substance that also may promote the release of norepinephrine and epinephrine. However, acute ingestion of caffeine (as coffee or tea) does not cause atrial fibrillation. Even patients suffering a myocardial infarction do not have an increased incidence of ventricular or other arrhythmias after ingesting several cups of coffee. Large epidemiologic studies have also failed to find a connection between the amount of coffee/caffeine used and the development of arrhythmias. As such, it does not make sense to suggest that patients with palpitations, paroxysmal atrial fibrillation, or supraventricular tachycardia, abstain from caffeine use. Energy drinks are a new phenomenon on the beverage market, with 30-50 % of young adults and teens using them regularly. Energy drinks are loaded with caffeine, sugar, and other chemicals that can stimulate the cardiac system. There is an increasing body of mainly anecdotal case reports describing arrhythmias or even sudden death triggered by exercise plus using energy drinks. Clearly, there must be more study in this area, but it is wise to either limit or avoid their use in patients with arrhythmias. Moderate to heavy alcohol use seems to be associated with the development of atrial fibrillation. The term "holiday heart" was coined back in 1978, to describe patients who had atrial fibrillation following binge alcohol use. Thus, it is reasonable to recommend to patients with arrhythmias that they limit their alcohol use, although unfortunately this treatment will likely not completely resolve their

  20. Depth variations of P-wave azimuthal anisotropy beneath East Asia

    Science.gov (United States)

    Wei, W.; Zhao, D.; Xu, J.

    2017-12-01

    We present a new P-wave anisotropic tomographic model beneath East Asia by inverting a total of 1,488,531 P wave arrival-time data recorded by the regional seismic networks in East Asia and temporary seismic arrays deployed on the Tibetan Plateau. Our results provide important new insights into the subducting Indian, Pacific and Philippine Sea plates and mantle dynamics in East Asia. Our tomographic images show that the northern limit of the subducting Indian plate has reached the Jinsha River suture in eastern Tibet. A striking variation of P-wave azimuthal anisotropy is revealed in the Indian lithosphere: the fast velocity direction (FVD) is NE-SW beneath the Indian continent, whereas the FVD is arc parallel beneath the Himalaya and Tibetan Plateau, which may reflect re-orientation of minerals due to lithospheric extension, in response to the India-Eurasia collision. The FVD in the subducting Philippine Sea plate beneath the Ryukyu arc is NE-SW(trench parallel), which is consistent with the spreading direction of the West Philippine Basin during its initial opening stage, suggesting that it may reflect the fossil anisotropy. A circular pattern of FVDs is revealed around the Philippine Sea slab beneath SE China. We suggest that it reflects asthenospheric strain caused by toroidal mantle flow around the edge of the subducting slab. We find a striking variation of the FVD with depth in the subducting Pacific slab beneath the Northeast Japan arc. It may be caused by slab dehydration that changed elastic properties of the slab with depth. The FVD in the mantle wedge beneath the Northeast Japan and Ryukyu arcs is trench normal, which reflects subduction-induced convection. Beneath the Kuril and Izu-Bonin arcs where oblique subduction occurs, the FVD in the mantle wedge is nearly normal to the moving direction of the downgoing Pacific plate, suggesting that the oblique subduction together with the complex slab morphology have disturbed the mantle flow.

  1. Family and population strategies for screening and counselling of inherited cardiac arrhythmias

    NARCIS (Netherlands)

    Van Langen, I.M.; Hofman, N.; Tan, H.L.; Wilde, A.A.M.

    2004-01-01

    Family screening in inherited cardiac arrhythmias has been performed in The Netherlands since 1996, when diagnostic DNA testing in long QT syndrome (LOTS) and hypertrophic cardiomyopathy (HCM) became technically possible. In multidisciplinary outpatient academic clinics, an adjusted protocol for

  2. P-polarized surface waves in a slab waveguide with left-handed material for sensing applications

    International Nuclear Information System (INIS)

    Taya, Sofyan A.

    2015-01-01

    In this paper, surface waves excited at the interface between left-handed and right-handed materials are employed for sensing applications. The propagation of p-polarized (TM) surface waves in a three-layer slab waveguide structure with air core layer as an analyte and anisotropic left-handed materials as claddings is investigated for detection of any changes in the refractive index of the analyte. The dispersion equations and the sensitivity of the effective refractive index to any change in the air layer index are derived, plotted, and discussed in details. The field profile is also explored. It is found that the sensitivity of the proposed surface wave sensor is almost independent of the wavelength of the propagating wave. A considerable sensitivity improvement can be obtained with the increase of transverse components of the left-handed material permittivity. - Highlights: • P-polarized surface waves in a three-layer slab waveguide are employed for sensing applications. • The structure contains air core layer as an analyte and anisotropic left-handed material in the claddings. • The sensitivity is found to be almost independent of the wavelength of the propagating wave. • Unusual sensitivity enhancement is observed as the transverse components of the LHM permittivity increase. • The asymmetric waveguide structure exhibits much higher sensitivity compared to the symmetric one

  3. Computational model based approach to analysis ventricular arrhythmias: Effects of dysfunction calcium channels

    Science.gov (United States)

    Gulothungan, G.; Malathi, R.

    2018-04-01

    Disturbed sodium (Na+) and calcium (Ca2+) handling is known to be a major predisposing factor for life-threatening cardiac arrhythmias. Cardiac contractility in ventricular tissue is prominent by Ca2+ channels like voltage dependent Ca2+ channels, sodium-calcium exchanger (Na+-Ca2+x) and sacroplasmicrecticulum (SR) Ca2+ pump and leakage channels. Experimental and clinical possibilities for studying cardiac arrhythmias in human ventricular myocardium are very limited. Therefore, the use of alternative methods such as computer simulations is of great importance. Our aim of this article is to study the impact on action potential (AP) generation and propagation in single ventricular myocyte and ventricular tissue under different dysfunction Ca2+ channels condition. In enhanced activity of Na+-Ca2+x, single myocyte produces AP duration (APD90) and APD50 is significantly smaller (266 ms and 235 ms). Its Na+-Ca2+x current at depolarization is increases 60% from its normal level and repolarization current goes more negative (nonfailing= -0.28 pA/pF and failing= -0.47 pA/pF). Similarly, same enhanced activity of Na+-Ca2+x in 10 mm region of ventricular sheet, raises the plateau potential abruptly, which ultimately affects the diastolic repolarization. Compare with normal ventricular sheet region of 10 mm, 10% of ventricular sheet resting state is reduces and ventricular sheet at time 250 ms is goes to resting state very early. In hypertrophy condition, single myocyte produces APD90 and APD50 is worthy of attention smaller (232 mS and 198 ms). Its sodium-potassium (Na+-K+) pump current is 75% reduces from its control conditions (0.13 pA/pF). Hypertrophy condition, 50% of ventricular sheet is reduces to minimum plateau potential state, that starts the repolarization process very early and reduces the APD. In a single failing SR Ca2+ channels myocyte, recovery of Ca2+ concentration level in SR reduces upto 15% from its control myocytes. At time 290 ms, 70% of ventricular sheet

  4. Cardiac Arrhythmia: In vivo screening in the zebrafish to overcome complexity in drug discovery.

    Science.gov (United States)

    Macrae, Calum A

    2010-07-01

    IMPORTANCE OF THE FIELD: Cardiac arrhythmias remain a major challenge for modern drug discovery. Clinical events are paroxysmal, often rare and may be asymptomatic until a highly morbid complication. Target selection is often based on limited information and though highly specific agents are identified in screening, the final efficacy is often compromised by unanticipated systemic responses, a narrow therapeutic index and substantial toxicities. AREAS COVERED IN THIS REVIEW: Our understanding of complexity of arrhythmogenesis has grown dramatically over the last two decades, and the range of potential disease mechanisms now includes pathways previously thought only tangentially involved in arrhythmia. This review surveys the literature on arrhythmia mechanisms from 1965 to the present day, outlines the complex biology underlying potentially each and every rhythm disturbance, and highlights the problems for rational target identification. The rationale for in vivo screening is described and the utility of the zebrafish for this approach and for complementary work in functional genomics is discussed. Current limitations of the model in this setting and the need for careful validation in new disease areas are also described. WHAT THE READER WILL GAIN: An overview of the complex mechanisms underlying most clinical arrhythmias, and insight into the limits of ion channel conductances as drug targets. An introduction to the zebrafish as a model organism, in particular for cardiovascular biology. Potential approaches to overcoming the hurdles to drug discovery in the face of complex biology including in vivo screening of zebrafish genetic disease models. TAKE HOME MESSAGE: In vivo screening in faithful disease models allows the effects of drugs on integrative physiology and disease biology to be captured during the screening process, in a manner agnostic to potential drug target or targets. This systematic strategy bypasses current gaps in our understanding of disease

  5. The effect of instanton-induced interaction on P-wave meson spectra ...

    Indian Academy of Sciences (India)

    possible to reproduce the observed spectra as the tensor and spin-orbit terms of. OGEP are attractive, and hence naturally triplet states masses will be lower than the corresponding singlet states. Hence, to reproduce the full P-wave spectra it is essential to include the hyperfine interaction term of III to have a consistent. 76.

  6. Electron-He+ P-wave elastic scattering and photoabsorption in two-electron systems

    International Nuclear Information System (INIS)

    Bhatia, A. K.

    2006-01-01

    In a previous paper [A. K. Bhatia, Phys. Rev. A 69, 032714 (2004)], electron-hydrogen P-wave scattering phase shifts were calculated using the optical potential approach based on the Feshbach projection operator formalism. This method is now extended to the singlet and triplet electron-He + P-wave scattering in the elastic region. Phase shifts are calculated using Hylleraas-type correlation functions with up to 220 terms. Results are rigorous lower bounds to the exact phase shifts, and they are compared to phase shifts obtained from the method of polarized orbitals and close-coupling calculations. The continuum functions calculated here are used to calculate photoabsorption cross sections. Photoionization cross sections of He and photodetachment cross sections of H - are calculated in the elastic region--i.e., leaving He + and H in their respective ground states--and compared with previous calculations. Radiative attachment rates are also calculated

  7. Reduction of false arrhythmia alarms using signal selection and machine learning

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2016-01-01

    In this paper, we propose an algorithm that classifies whether a generated cardiac arrhythmia alarm is true or false. The large number of false alarms in intensive care is a severe issue. The noise peaks caused by alarms can be high and in a noisy environment nurses can experience stress and

  8. P-wave attenuation in the Pacific slab beneath northeastern Japan revealed by the spectral ratio of intraslab earthquakes

    Science.gov (United States)

    Shiina, Takahiro; Nakajima, Junichi; Matsuzawa, Toru

    2018-05-01

    We investigate P-wave attenuation, Qp-1, in the Pacific slab beneath northeastern (NE) Japan, adopting for the first time the spectral ratio technique for intraslab earthquakes. When seismograms of two earthquakes are recorded at a station and their ray paths to the station are largely overlapped, station-dependent amplification and structural effects on the overlapped rays can be canceled out from the ratio of the spectral amplitudes of the seismograms. Therefore, adopting the spectral ratio technique for intraslab earthquakes has a great advantage for the precise evaluation of Qp-1 in the slab because the structural effects above the slab, including the high-attenuation mantle wedge, are removed. For estimating the intraslab Qp-1, we determined corner frequency of the intraslab earthquakes using the S-coda wave spectral ratio as the first step. Then, we evaluated the inter-event path attenuation, Δt*, from the ratio of the spectral amplitudes of P waves. The obtained result shows that P-wave attenuation in the Pacific slab marks Qp-1 of 0.0015 (Qp of ∼670) at depths of 50-250 km. This indicates that the P-wave attenuation in the Pacific slab is weaker than that in the mantle wedge. The relatively high-Qp-1 is correlated with the distributions of intraslab earthquakes, suggesting that the P-wave amplitude is more attenuated around active seismicity zones in the slab. Therefore, our observations likely indicate the presence of fractures, hydrous minerals, and dehydrated fluid around seismogenic zones in the slab at intermediate depths.

  9. Transcatheter radiofrequency ablation under the guidance of three-dimensional mapping for the treatment of complex cardiac arrhythmias

    International Nuclear Information System (INIS)

    Hong Lang; Wang Hong; Lai Hengli; Ying Qiulin; Chen Zhangqiang; Lu Linxiang; Qiu Yun; Xiao Chengwei

    2010-01-01

    Objective: To investigate the effectiveness and safety of transcatheter radiofrequency ablation guided by a three-dimensional mapping system (Ensite or Carto) for the treatment of complex cardiac arrhythmias. Methods: A cohort of 123 consecutive hospitalized inpatients during the period from February 2006 to December 2008 were selected for this study. These patients suffered from various arrhythmias, including paroxysmal atrial fibrillation (n = 58), persistent or permanent atrial fibrillation (n = 10), atrial flutter (n = 13), atrial tachycardia (n = 12) and ventricular tachycardia or frequent ventricular premature beats (n = 30). Transcatheter radiofrequency ablation for arrhythmias was performed under the guidance of an EnSite3000 / NavX or Array mapping system in 80 cases, and under the guidance of a CARTO mapping system in the remaining 43 cases. Results: Successful ablation of arrhythmias was obtained by single operation in 106 cases (86.18%), including 59 cases with atrial fibrillation, 11 cases with atrial flutter, 10 cases with atrial tachycardia, and 26 cases with ventricular tachycardia or premature ventricular beat.Ablation procedure was carried out and was successful in 10 cases with a successful rate of 94.31%, including 5 cases with atrial fibrillation, 1 case with recurred atrial flutter, 1 case with recurrent atrial tachycardia, and 3 cases with ventricular tachycardia or premature ventricular beat.After operation, complications occurred in 6 cases, including cardiac tamponade in 4 cases, distal embolism of the left anterior descending coronary artery in 1 case, and pulmonary embolism in 1 case. Conclusion: Three-dimensional mapping system can clearly and stereoscopically display the cardiac structures. Therefore, this technique is of great value in guiding the transcatheter radiofrequency ablation for complex arrhythmias, in improving the success rate of ablation and in increasing the safety of the procedure. (authors)

  10. How valuable is P-wave dispersion in the determination of carboxyhemoglobin levels?

    Science.gov (United States)

    Sener, M T; Anci, Y; Kalkan, K; Kir, M Z; Emet, M

    2014-05-01

    To determine whether or not wave/interval dispersions in electrocardiography (ECG) are increased, and to define whether wave and interval dispersions are correlated with carboxyhemoglobin (COHb) levels. ECG, complete blood count, and biochemical parameters were taken from 87 patients with carbon monoxide (CO) poisoning as well as 90 control patients with similar age, gender, and body mass index distribution. COHb levels were recorded in CO-poisoning patients. The COHb levels and the relationships with ECG parameters were studied. Pmax, Pmin, Pd, PRmax, PRmin, PRd, QTmax, QTmin, QTd, cQTmax, cQTmin, cQTd, Tmax, Tmin, and Td in ECG were higher in intoxicated patients than the control group (p < 0.05 for all). Pearson's correlation analyses showed moderately significant positive correlations between COHb level and Pmax (r = 0.224; p = 0.037) and Pd (r = 0.222; p = 0.039). The receiver-operator characteristic (ROC) curve showed that a Pd value of 38 ms determined by ECG separates patients with a COHb ≥ 20% with area under the ROC curve of 0.78 (95%CI = 0.71-0.83), a sensitivity of 67.9% (95%CI = 59.4-75.6), a specificity of 95% (95%CI = 83.0-99.2], a positive predictive value of 97.9% (95%CI = 92.5-99.7), and a negative predictive value of 46.3% (95%CI = 35.3-57.7.) A significant increase in wave/interval dispersions in the ECG of CO-poisoning patients compared with controls may show that not only a part is affected but both atrium and the ventricles as a whole are affected by hypoxic ischemia. When COHb levels of the patients are unavailable, P dispersion on ECG may show CO poisoning level of the patient.

  11. A multicenter, long-term study on arrhythmias in children with Ebstein anomaly.

    NARCIS (Netherlands)

    Delhaas, T.; Sarvaas, G.J.; Rijlaarsdam, M.E.; Strengers, J.L.; Eveleigh, R.M.; Poulino, S.E.; Korte, C.L. de; Kapusta, L.

    2010-01-01

    To assess the prevalence, history, and treatment of arrhythmias, in particular preexcitation and Wolff-Parkinson-White (WPW) syndrome, in patients with Ebstein anomaly (EA) during childhood and adolescence, we performed a multicenter retrospective study of all consecutive live-born patients with EA,

  12. A Multicenter, Long-Term Study on Arrhythmias in Children with Ebstein Anomaly

    NARCIS (Netherlands)

    Delhaas, Tammo; Sarvaas, Gideon J. du Marchie; Rijlaarsdam, Marry E.; Strengers, Jan L.; Eveleigh, Rhona M.; Poulino, Sumayah E.; de Korte, Chris L.; Kapusta, Livia

    To assess the prevalence, history, and treatment of arrhythmias, in particular preexcitation and Wolff-Parkinson-White (WPW) syndrome, in patients with Ebstein anomaly (EA) during childhood and adolescence, we performed a multicenter retrospective study of all consecutive live-born patients with EA,

  13. [Treatment of arrhythmia in coronary patients and hypertensives with beta blockers and Depasan retard].

    Science.gov (United States)

    Kandziora, J

    1981-05-14

    In the ambulatory of an internal specialist a number of patients suffering from angina pectoris or hypertonia together with arrhythmic troubles received an initial treatment with beta-blockers over a period of 21 days. In cases in which arrhythmia persisted after this initial period the treatment was continued for another 21 days with the addition of Depasan retard in function of a second medicament. This combined treatment in form of an open study was extended to a total number of 50 patients presenting ventricular extrasystolia in 45 cases and in 5 cases absolute arrhythmia in addition to the main disease. Treatment with Depasan retard showed good or satisfactory results in 39 out of 45 patients suffering from ventricular extrasystoles, whilst no effect could be obtained in the 5 cases with absolute arrhythmia. No signs of incompatibility or unwanted interactions were observed in the course of this open study. Based on these results it can be concluded that Depasan retard should be recommended in those cases where on account of persistent arrhythmical troubles and especially extrasystoles, during a treatment with beta-blockers in patients suffering from angina pectoris or hypertonia, and additional treatment with anti-arrhythmical medicaments appears to be indicated.

  14. Automatic recognition of cardiac arrhythmias based on the geometric patterns of Poincaré plots

    International Nuclear Information System (INIS)

    Zhang, Lijuan; Guo, Tianci; Xi, Bin; Fan, Yang; Wang, Kun; Bi, Jiacheng; Wang, Ying

    2015-01-01

    The Poincaré plot emerges as an effective tool for assessing cardiovascular autonomic regulation. It displays nonlinear characteristics of heart rate variability (HRV) from electrocardiographic (ECG) recordings and gives a global view of the long range of ECG signals. In the telemedicine or computer-aided diagnosis system, it would offer significant auxiliary information for diagnosis if the patterns of the Poincaré plots can be automatically classified. Therefore, we developed an automatic classification system to distinguish five geometric patterns of the Poincaré plots from four types of cardiac arrhythmias. The statistics features are designed on measurements and an ensemble classifier of three types of neural networks is proposed. Aiming at the difficulty to set a proper threshold for classifying the multiple categories, the threshold selection strategy is analyzed. 24 h ECG monitoring recordings from 674 patients, which have four types of cardiac arrhythmias, are adopted for recognition. For comparison, Support Vector Machine (SVM) classifiers with linear and Gaussian kernels are also applied. The experiment results demonstrate the effectiveness of the extracted features and the better performance of the designed classifier. Our study can be applied to diagnose the corresponding sinus rhythm and arrhythmia substrates disease automatically in the telemedicine and computer-aided diagnosis system. (paper)

  15. Mantle Attenuation Estimated from Regional and Teleseismic P-waves of Deep Earthquakes and Surface Explosions

    Science.gov (United States)

    Ichinose, G.; Woods, M.; Dwyer, J.

    2014-03-01

    We estimated the network-averaged mantle attenuation t*(total) of 0.5 s beneath the North Korea test site (NKTS) by use of P-wave spectra and normalized spectral stacks from the 25 May 2009 declared nuclear test (mb 4.5; IDC). This value was checked using P-waves from seven deep (580-600 km) earthquakes (4.8 test, which confirms the equality with the sum of t*(u) and t*(d). We included constraints on seismic moment, depth, and radiation pattern by using results from a moment tensor analysis and corner frequencies from modeling of P-wave spectra recorded at local distances. We also avoided finite-faulting effects by excluding earthquakes with complex source time functions. We assumed ω2 source models for earthquakes and explosions. The mantle attenuation beneath the NKTS is clearly different when compared with the network-averaged t* of 0.75 s for the western US and is similar to values of approximately 0.5 s for the Semipalatinsk test site within the 0.5-2 Hz range.

  16. Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering.

    Science.gov (United States)

    Xia, Yong; Han, Junze; Wang, Kuanquan

    2015-01-01

    Based on the idea of telemedicine, 24-hour uninterrupted monitoring on electrocardiograms (ECG) has started to be implemented. To create an intelligent ECG monitoring system, an efficient and quick detection algorithm for the characteristic waveforms is needed. This paper aims to give a quick and effective method for detecting QRS-complexes and R-waves in ECGs. The real ECG signal from the MIT-BIH Arrhythmia Database is used for the performance evaluation. The method proposed combined a wavelet transform and the K-means clustering algorithm. A wavelet transform is adopted in the data analysis and preprocessing. Then, based on the slope information of the filtered data, a segmented K-means clustering method is adopted to detect the QRS region. Detection of the R-peak is based on comparing the local amplitudes in each QRS region, which is different from other approaches, and the time cost of R-wave detection is reduced. Of the tested 8 records (total 18201 beats) from the MIT-BIH Arrhythmia Database, an average R-peak detection sensitivity of 99.72 and a positive predictive value of 99.80% are gained; the average time consumed detecting a 30-min original signal is 5.78s, which is competitive with other methods.

  17. An efficient hybrid pseudospectral/finite-difference scheme for solving the TTI pure P-wave equation

    KAUST Repository

    Zhan, Ge

    2013-02-19

    The pure P-wave equation for modelling and migration in tilted transversely isotropic (TTI) media has attracted more and more attention in imaging seismic data with anisotropy. The desirable feature is that it is absolutely free of shear-wave artefacts and the consequent alleviation of numerical instabilities generally suffered by some systems of coupled equations. However, due to several forward-backward Fourier transforms in wavefield updating at each time step, the computational cost is significant, and thereby hampers its prevalence. We propose to use a hybrid pseudospectral (PS) and finite-difference (FD) scheme to solve the pure P-wave equation. In the hybrid solution, most of the cost-consuming wavenumber terms in the equation are replaced by inexpensive FD operators, which in turn accelerates the computation and reduces the computational cost. To demonstrate the benefit in cost saving of the new scheme, 2D and 3D reverse-time migration (RTM) examples using the hybrid solution to the pure P-wave equation are carried out, and respective runtimes are listed and compared. Numerical results show that the hybrid strategy demands less computation time and is faster than using the PS method alone. Furthermore, this new TTI RTM algorithm with the hybrid method is computationally less expensive than that with the FD solution to conventional TTI coupled equations. © 2013 Sinopec Geophysical Research Institute.

  18. An efficient hybrid pseudospectral/finite-difference scheme for solving the TTI pure P-wave equation

    International Nuclear Information System (INIS)

    Zhan, Ge; Pestana, Reynam C; Stoffa, Paul L

    2013-01-01

    The pure P-wave equation for modelling and migration in tilted transversely isotropic (TTI) media has attracted more and more attention in imaging seismic data with anisotropy. The desirable feature is that it is absolutely free of shear-wave artefacts and the consequent alleviation of numerical instabilities generally suffered by some systems of coupled equations. However, due to several forward–backward Fourier transforms in wavefield updating at each time step, the computational cost is significant, and thereby hampers its prevalence. We propose to use a hybrid pseudospectral (PS) and finite-difference (FD) scheme to solve the pure P-wave equation. In the hybrid solution, most of the cost-consuming wavenumber terms in the equation are replaced by inexpensive FD operators, which in turn accelerates the computation and reduces the computational cost. To demonstrate the benefit in cost saving of the new scheme, 2D and 3D reverse-time migration (RTM) examples using the hybrid solution to the pure P-wave equation are carried out, and respective runtimes are listed and compared. Numerical results show that the hybrid strategy demands less computation time and is faster than using the PS method alone. Furthermore, this new TTI RTM algorithm with the hybrid method is computationally less expensive than that with the FD solution to conventional TTI coupled equations. (paper)

  19. Application of perturbation theory to a P-wave eikonal equation in orthorhombic media

    KAUST Repository

    Stovas, Alexey; Masmoudi, Nabil; Alkhalifah, Tariq Ali

    2016-01-01

    The P-wave eikonal equation for orthorhombic (ORT) anisotropic media is a highly nonlinear partial differential equation requiring the solution of a sixth-order polynomial to obtain traveltimes, resulting in complex and time-consuming numerical

  20. Risk of malignant arrhythmias in initially symptomatic patients with Wolff-Parkinson-White syndrome: results of a prospective long-term electrophysiological follow-up study.

    Science.gov (United States)

    Pappone, Carlo; Vicedomini, Gabriele; Manguso, Francesco; Baldi, Mario; Pappone, Alessia; Petretta, Andrea; Vitale, Raffaele; Saviano, Massimo; Ciaccio, Cristiano; Giannelli, Luigi; Calovic, Zarko; Tavazzi, Luigi; Santinelli, Vincenzo

    2012-02-07

    The available amount of detailed long-term data in patients with Wolff-Parkinson-White syndrome is limited, and no prospective electrophysiological studies looking at predictors of malignant arrhythmia are available. Among 8575 symptomatic Wolff-Parkinson-White patients with atrioventricular reentrant tachycardia referred for electrophysiological test, 369 (mean age, 23±12.5 years) declined catheter ablation and were followed up. The primary end point of the study was to evaluate over a 5-year follow-up the predictors and characteristics of patients who develop malignant arrhythmias. After a mean follow-up of 42.1±10 months, malignant arrhythmias developed in 29 patients (mean age, 13.9±5.6 years; 26 male), resulting in presyncope/syncope (25 patients), hemodynamic collapse (3 patients), or cardiac arrest caused by ventricular fibrillation (1 patient). Of the remaining 340 patients, 168 (mean age, 34.2±9.0 years) remained asymptomatic up to 5 years, and 172 (mean age, 13.6±5.1 years) had benign recurrence, including sustained atrioventricular reentrant tachycardia (132 patients) or atrial fibrillation (40 patients). Compared with the group with no malignant arrhythmias, the group with malignant arrhythmias showed shorter accessory-pathway effective refractory period (PWolff-Parkinson-White syndrome generally have a good outcome, and predictors of malignant arrhythmias are similar to those reported for asymptomatic patients with ventricular pre-excitation.

  1. Noninvasive evaluation of reverse atrial remodeling after catheter ablation of atrial fibrillation by P wave dispersion.

    Science.gov (United States)

    Fujimoto, Yuhi; Yodogawa, Kenji; Takahashi, Kenta; Tsuboi, Ippei; Hayashi, Hiroshi; Uetake, Shunsuke; Iwasaki, Yu-Ki; Hayashi, Meiso; Miyauchi, Yasushi; Shimizu, Wataru

    2017-11-01

    Atrial fibrillation (AF) itself creates structural and electrophysiological changes such as atrial enlargement, shortening of refractory period and decrease in conduction velocity, called "atrial remodeling", promoting its persistence. Although the remodeling process is considered to be reversible, it has not been elucidated in detail. The aim of this study was to assess the feasibility of P wave dispersion in the assessment of reverse atrial remodeling following catheter ablation of AF. Consecutive 126 patients (88 males, age 63.0 ± 10.4 years) who underwent catheter ablation for paroxysmal AF were investigated. P wave dispersion was calculated from the 12 lead ECG before, 1 day, 1 month, 3 months and 6 months after the procedure. Left atrial diameter (LAD), left atrial volume index (LAVI), left ventricular ejection fraction (LVEF), transmitral flow velocity waveform (E/A), and tissue Doppler (E/e') on echocardiography, plasma B-type natriuretic peptide (BNP) concentrations, serum creatinine, and estimated glomerular filtration rate (eGFR) were also measured. Of all patients, 103 subjects remained free of AF for 1 year follow-up. In these patients, P wave dispersion was not changed 1 day and 1 month after the procedure. However, it was significantly decreased at 3 and 6 months (50.1 ± 14.8 to 45.4 ± 14.4 ms, p < 0.05, 45.2 ± 9.9 ms, p < 0.05, respectively). Plasma BNP concentrations, LAD and LAVI were decreased (81.1 ± 103.8 to 44.8 ± 38.3 pg/mL, p < 0.05, 38.2 ± 5.7 to 35.9 ± 5.6 mm, p < 0.05, 33.3 ± 14.2 to 29.3 ± 12.3 mL/m 2 , p < 0.05) at 6 months after the procedure. There were no significant changes in LVEF, E/A, E/e', serum creatinine, and eGFR during the follow up period. P wave dispersion was decreased at 3 and 6 months after catheter ablation in patients without recurrence of AF. P wave dispersion is useful for assessment of reverse remodeling after catheter ablation of AF.

  2. Gas-hydrate concentration estimated from P- and S-wave velocities at the Mallik 2L-38 research well, Mackenzie Delta, Canada

    Science.gov (United States)

    Carcione, José M.; Gei, Davide

    2004-05-01

    We estimate the concentration of gas hydrate at the Mallik 2L-38 research site using P- and S-wave velocities obtained from well logging and vertical seismic profiles (VSP). The theoretical velocities are obtained from a generalization of Gassmann's modulus to three phases (rock frame, gas hydrate and fluid). The dry-rock moduli are estimated from the log profiles, in sections where the rock is assumed to be fully saturated with water. We obtain hydrate concentrations up to 75%, average values of 37% and 21% from the VSP P- and S-wave velocities, respectively, and 60% and 57% from the sonic-log P- and S-wave velocities, respectively. The above averages are similar to estimations obtained from hydrate dissociation modeling and Archie methods. The estimations based on the P-wave velocities are more reliable than those based on the S-wave velocities.

  3. Non cancerous diseases following a chronic intern contamination by caesium 137: cataracts and cardiac arrhythmias

    International Nuclear Information System (INIS)

    Landon, G.

    2008-07-01

    This work of thesis joins within the framework of an analysis of the sanitary consequences of the nuclear accident of Chernobylsk. Since 2005, the I.R.S.N. is interested in the not cancerous pathologies (cataracts, and cardiac arrhythmias) observed among the children living on the contaminated territories after the fallout of Chernobylsk and has in this aim implemented a research programme called E.P.I.C.E. (Evaluation of the pathologies induced by a chronicle contamination by cesium) whom objective is to show an eventual link between the chronicle ingestion of contaminated food and these pathologies emergence. An exploitation of the results of the pilot study,first phase of the E.P.I.C.E. program was realized. The analysis was completed by two bibliographical reviews relative to the knowledge available on these diseases. The results of this pilot study suggest: on one hand, an absence of link between the activity in cesium 137 at the level of the heart, of the whole body and the emergence of disorder of the heart rhythm; on the other hand, for the cases of cataract, a link between the load in cesium 137 at the neck level and the emergence of the disease in 40 % of the cases. However, these results must be considered with caution because several limits and, in particular, a way of selection affect this study. concerning the scientific literature, this one stays rather poor because only thee articles make reference to a relationship between cesium 137 and the emergence of these non cancerous pathologies. After having exposed the context, this thesis draws up the situation of knowledge relative to cataracts and to cardiac arrhythmias and their possible relationship with ionizing radiations, collect the results stemming from the analysis of the pilot study and envisages future epidemiological studies. (N.C.)

  4. Induced pluripotent stem cell derived cardiomyocytes as models for cardiac arrhythmias

    Directory of Open Access Journals (Sweden)

    Maaike eHoekstra

    2012-08-01

    Full Text Available Cardiac arrhythmias are a major cause of morbidity and mortality. In younger patients, the majority of sudden cardiac deaths have an underlying Mendelian genetic cause. Over the last 15 years, enormous progress has been made in identifying the distinct clinical phenotypes and in studying the basic cellular and genetic mechanisms associated with the primary Mendelian (monogenic arrhythmia syndromes. Investigation of the electrophysiological consequences of an ion channel mutation is ideally done in the native cardiomyocyte environment. However, the majority of such studies so far have relied on heterologous expression systems in which single ion channel genes are expressed in non-cardiac cells. In some cases, transgenic mouse models haven been generated, but these also have significant shortcomings, primarily related to species differences.The discovery that somatic cells can be reprogrammed to pluripotency as induced pluripotent stem cells (iPSC has generated much interest since it presents an opportunity to generate patient- and disease-specific cell lines from which normal and diseased human cardiomyocytes can be obtained These genetically diverse human model systems can be studied in vitro and used to decipher mechanisms of disease and identify strategies and reagents for new therapies. Here we review the present state of the art with respect to cardiac disease models already generated using IPSC technology and which have been (partially characterized.Human iPSC (hiPSC models have been described for the cardiac arrhythmia syndromes, including LQT1, LQT2, LQT3-Brugada Syndrome, LQT8/Timothy syndrome and catecholaminergic polymorphic ventricular tachycardia. In most cases, the hiPSC-derived cardiomyoctes recapitulate the disease phenotype and have already provided opportunities for novel insight into cardiac pathophysiology. It is expected that the lines will be useful in the development of pharmacological agents for the management of these

  5. Predictors of the left ventricular dysfunction induced by ventricular arrhythmia

    Directory of Open Access Journals (Sweden)

    А. І. Vytryhovskiy

    2016-08-01

    Full Text Available The most powerful predictor of life-threatening arrhythmia risk is a combination of low heart rate variability with low ejection fraction (EF of the left ventricle. Aim. To identify predictors of left ventricle dysfunction which is induced by ventricular arrhythmia. Materials and methods. To diagnose structural changes of left ventricular functional capacity and reserves in patients with previous myocardial infarction and patients with high and very high cardiovascular risk by SCORE scale and for establishment the relationship between morphological heart changes and pathological phenomenon of heart turbulence echocardiography and study of heart rate turbulence variability were performed. 603 patients were selected for the research. All patients were divided into groups: group 1 – patients with coronary heart disease, but without associated risk factors, such as smoking, obesity, metabolic syndrome; group 2 – patients who smoke tobacco more than 2 years (very high cardiovascular risk by scale SCORE; group 3 – patients with metabolic syndrome without coronary heart disease or arterial hypertension (very high cardiovascular risk by scale SCORE. The control group consisted of 149 persons. Results. The feature of structural changes in patients with myocardial infarction and in patients with a high cardiovascular risk by SCORE with heart rate turbulence compared with cases without НRT is considerably thickening of the left interventricular septum in systole. Based on this, it can be argued that the emergence of ventricular arrhythmia and accordingly phenomenon of heart rate turbulence in patients with existing cardiovascular diseases and risk factors has both morphological and functional character. Significant difference of echocardioscopy parameters in patients with postinfarction cardiosclerosis and risk factors by the SCORE system was established by index of intraventricular septum thickness in systole, and in persons with high risk – in

  6. Role of Pre-incision, Intravenous Prophylactic Amiodarone to Control Arrhythmias in Patients with Rheumatic Valvular Heart Disease undergoing Mitral Valve Replacement

    International Nuclear Information System (INIS)

    Ahmad, K.; Naqvi, S.

    2013-01-01

    Objective: To evaluate the effect of intra-operative single intra venous dose of amiodarone on post operative cardiac arrhythmias in patients undergoing valvular heart surgery. Study Design: Randomized controlled trials. Place and Duration of surgery: This study was performed at Armed forces Institute of Cardiology Rawalpindi from Jan 01, 2011 to Dec 31, 2011. Patients and Methods: In this study 80 patients with rheumatic valvular heart disease and undergoing elective mitral valve replacement were randomly divided into two groups. Group I, n = 40 (Amiodarone group) was given single intravenous dose of amiodarone (5 mg/kg in 100 ml of saline over 30 min) before sternotomy incision. Group II, n = 40(control / placebo group) was given 100 ml of saline over 30 min. Result: In the amiodarone group, after removal of aortic cross clamp 75% patients had sinus rhythm compared to 47.5% in control group. p=0.045. Similarly 15% had AF, 5% JR and 5% VT/VF in amiodarone group in contrast to 32.5% with AF, 12.5% JR and 7.5% Vt/VF in control group. (p=0.045). Response to cardioversion was positive in 75% of the patients requiring shocks in amiodarone group as against 43.75% in the control group. (p=0.044). Conclusion: A single intravenous bolus dose of amiodarone is effective in decreasing the incidence of cardiac arrhythmias after mitral valve replacement in patients with rheumatic MVD. (author)

  7. Assessment of atrial electromechanical interval and P wave dispersion in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Bayır, Pınar Türker; Güray, Ümit; Duyuler, Serkan; Demirkan, Burcu; Kayaalp, Oya; Kanat, Selçuk; Güray, Yeşim

    2016-02-01

    Polycystic ovary syndrome (PCOS) is associated with increased cardiovascular risk, including ischemic stroke. Prolonged atrial electromechanical interval (EMI) is related to increased atrial fibrillation (AF) risk. The aim of the study is to evaluate atrial EMI and electrocardiographic P-wave indices related to increased AF risk in patients with PCOS. Forty PCOS patients diagnosed on the basis of the Rotterdam criteria and 20 age-matched controls were prospectively included. patients with atrioventricular or intraventricular conduction abnormalities, dysrhythmia or taking antiarrhythmic drugs, atherosclerotic heart disease, cardiomyopathies, valvular lesions, pericardial disease, a history of pulmonary emboli or pulmonary hypertension, and abnormal thyroid function were excluded. Intra and interatrial EMI were measured by tissue Doppler imaging and P-wave dispersion (Pd) was calculated on 12-lead electrocardiography (ECG). The Isovolumetric relaxation time was the interval between the aortic valve closure artifact at the end of the LV outflow envelope and the mitral valve opening artifact at the beginning of the mitral E wave. Patients with PCOS had significantly higher interatrial [38 (24-65) ms vs. 16 (9-19) ms pPCOS group compared with control group [45 (27-60) ms vs. 30 (26-38) ms, pPCOS. PCOS is associated with prolonged inter- and intra-atrial conduction times, which are related to increased AF risk.

  8. Constraining dark matter late-time energy injection: decays and p-wave annihilations

    Energy Technology Data Exchange (ETDEWEB)

    Diamanti, Roberta; Mena, Olga; Palomares-Ruiz, Sergio; Vincent, Aaron C. [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lopez-Honorez, Laura, E-mail: R.Diamanti@uva.nl, E-mail: llopezho@vub.ac.be, E-mail: omena@ific.uv.es, E-mail: sergio.palomares.ruiz@ific.uv.es, E-mail: vincent@ific.uv.es [Theoretische Natuurkunde Vrije Universiteit Brussel and The International Solvay Institutes Pleinlaan 2, B-1050 Brussels (Belgium)

    2014-02-01

    We use the latest cosmic microwave background (CMB) observations to provide updated constraints on the dark matter lifetime as well as on p-wave suppressed annihilation cross sections in the 1 MeV to 1 TeV mass range. In contrast to scenarios with an s-wave dominated annihilation cross section, which mainly affect the CMB close to the last scattering surface, signatures associated with these scenarios essentially appear at low redshifts (z∼<50) when structure began to form, and thus manifest at lower multipoles in the CMB power spectrum. We use data from Planck, WMAP9, SPT and ACT, as well as Lyman–α measurements of the matter temperature at z ∼ 4 to set a 95% confidence level lower bound on the dark matter lifetime of ∼ 4 × 10{sup 25} s for m{sub χ} = 100 MeV. This bound becomes lower by an order of magnitude at m{sub χ} = 1 TeV due to inefficient energy deposition into the intergalactic medium. We also show that structure formation can enhance the effect of p-wave suppressed annihilation cross sections by many orders of magnitude with respect to the background cosmological rate, although even with this enhancement, CMB constraints are not yet strong enough to reach the thermal relic value of the cross section.

  9. How a change in the interaction potential affects the p-wave scattering volume

    International Nuclear Information System (INIS)

    Jamieson, M J; Dalgarno, A

    2012-01-01

    We derive a simple expression for the change in the s-wave scattering length in terms of zero-energy wavefunctions, we generalize it to obtain an expression for the change in the p-wave scattering volume and we use both expressions to derive the first order differential equations of variable phase theory that are satisfied by the closely related accumulated scattering length and volume. We provide numerical demonstrations for the example of a pair of hydrogen atoms interacting via the X 1 Σ + g molecular state. (fast track communication)

  10. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    Science.gov (United States)

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  11. Experimental study on p-wave neutron strength functions for light nuclei

    International Nuclear Information System (INIS)

    Koester, L.; Waschkowski, W.; Meier, J.; Rau, G.; Salehi, M.

    1988-01-01

    Broad energy distributions in fast neutron beams have been achieved by appropriate filtering of the 236 U fission radiation provided from the RENT converter facility at the FRM research reactor. Transmission measurements in such beams result in average cross sections to which resonance reactions and shape elastic scattering contribute. We used a silicon (124.5 cm) filtered beam with a median energy of 143 keV (width 20 keV) and beams with 1.3 MeV (0.55 to 3 MeV) and 2.1 MeV (1 to 5.5 MeV) obtained through different filter combinations of lead and polyethylene. The relative high energies and the broad spectra made it possible to determine experimentally the contributions of s- and p-wave resonance reactions to the average cross section even for light nuclei. Using the three different beams we determined the average cross sections for the elements in the mass region A = 9 to 65. Analysing the measured cross sections by means of the R matrix formalism provided a complete set of p-wave strength functions and distant level parameters. Moreover, single particle shell effects in the cross sections were observed. In conclusion we obtained information on the 2P and the 3S size resonances and about the validity of the optical model for neutron reactions with light nuclei. (orig.)

  12. Explosion Generated Seismic Waves and P/S Methods of Discrimination from Earthquakes with Insights from the Nevada Source Physics Experiments

    Science.gov (United States)

    Walter, W. R.; Ford, S. R.; Pitarka, A.; Pyle, M. L.; Pasyanos, M.; Mellors, R. J.; Dodge, D. A.

    2017-12-01

    The relative amplitudes of seismic P-waves to S-waves are effective at identifying underground explosions among a background of natural earthquakes. These P/S methods appear to work best at frequencies above 2 Hz and at regional distances ( >200 km). We illustrate this with a variety of historic nuclear explosion data as well as with the recent DPRK nuclear tests. However, the physical basis for the generation of explosion S-waves, and therefore the predictability of this P/S technique as a function of path, frequency and event properties such as size, depth, and geology, remains incompletely understood. A goal of current research, such as the Source Physics Experiments (SPE), is to improve our physical understanding of the mechanisms of explosion S-wave generation and advance our ability to numerically model and predict them. The SPE conducted six chemical explosions between 2011 and 2016 in the same borehole in granite in southern Nevada. The explosions were at a variety of depths and sizes, ranging from 0.1 to 5 tons TNT equivalent yield. The largest were observed at near regional distances, with P/S ratios comparable to much larger historic nuclear tests. If we control for material property effects, the explosions have very similar P/S ratios independent of yield or magnitude. These results are consistent with explosion S-waves coming mainly from conversion of P- and surface waves, and are inconsistent with source-size based models. A dense sensor deployment for the largest SPE explosion allowed this conversion to be mapped in detail. This is good news for P/S explosion identification, which can work well for very small explosions and may be ultimately limited by S-wave detection thresholds. The SPE also showed explosion P-wave source models need to be updated for small and/or deeply buried cases. We are developing new P- and S-wave explosion models that better match all the empirical data. Historic nuclear explosion seismic data shows that the media in which

  13. Holographic p-wave superfluid in Gauss–Bonnet gravity

    International Nuclear Information System (INIS)

    Liu, Shancheng; Pan, Qiyuan; Jing, Jiliang

    2017-01-01

    We construct the holographic p-wave superfluid in Gauss–Bonnet gravity via a Maxwell complex vector field model and investigate the effect of the curvature correction on the superfluid phase transition in the probe limit. We obtain the rich phase structure and find that the higher curvature correction hinders the condensate of the vector field but makes it easier for the appearance of translating point from the second-order transition to the first-order one or for the emergence of the Cave of Winds. Moreover, for the supercurrents versus the superfluid velocity, we observe that our results near the critical temperature are independent of the Gauss–Bonnet parameter and agree well with the Ginzburg–Landau prediction.

  14. Holographic p-wave superfluid in Gauss–Bonnet gravity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shancheng [Department of Physics, Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, Hunan Normal University, Changsha, Hunan 410081 (China); Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha, Hunan 410081 (China); Pan, Qiyuan, E-mail: panqiyuan@126.com [Department of Physics, Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, Hunan Normal University, Changsha, Hunan 410081 (China); Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha, Hunan 410081 (China); Jing, Jiliang, E-mail: jljing@hunnu.edu.cn [Department of Physics, Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, Hunan Normal University, Changsha, Hunan 410081 (China); Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha, Hunan 410081 (China)

    2017-02-10

    We construct the holographic p-wave superfluid in Gauss–Bonnet gravity via a Maxwell complex vector field model and investigate the effect of the curvature correction on the superfluid phase transition in the probe limit. We obtain the rich phase structure and find that the higher curvature correction hinders the condensate of the vector field but makes it easier for the appearance of translating point from the second-order transition to the first-order one or for the emergence of the Cave of Winds. Moreover, for the supercurrents versus the superfluid velocity, we observe that our results near the critical temperature are independent of the Gauss–Bonnet parameter and agree well with the Ginzburg–Landau prediction.

  15. Anti-HERG activity and the risk of drug-induced arrhythmias and sudden death

    DEFF Research Database (Denmark)

    De Bruin, M L; Pettersson, M; Meyboom, R H B

    2005-01-01

    AIMS: Drug-induced QTc-prolongation, resulting from inhibition of HERG potassium channels may lead to serious ventricular arrhythmias and sudden death. We studied the quantitative anti-HERG activity of pro-arrhythmic drugs as a risk factor for this outcome in day-to-day practice. METHODS...... defined as reports of cardiac arrest, sudden death, torsade de pointes, ventricular fibrillation, and ventricular tachycardia (n = 5591), and compared with non-cases regarding the anti-HERG activity, defined as the effective therapeutic plasma concentration (ETCPunbound) divided by the HERG IC50 value......, of suspected drugs. We identified a significant association of 1.93 (95% CI: 1.89-1.98) between the anti-HERG activity of drugs, measured as log10 (ETCPunbound/IC50), and reporting of serious ventricular arrhythmias and sudden death to the WHO-UMC database. CONCLUSION: Anti-HERG activity is associated...

  16. AANA Journal Course: update for nurse anesthetists. Arrhythmia management devices and electromagnetic interference.

    Science.gov (United States)

    Mattingly, Emily

    2005-04-01

    The technological complexity of implantable arrhythmia management devices, specifically pacemakers and defibrillators, has increased dramatically since their introduction only a few decades ago. Patients with such devices are encountered much more frequently in hospitals and surgery centers, yet anesthesia provider knowledge of safe and proper management is often incomplete. Anesthesia textbooks and references may provide only short paragraphs on arrhythmia management devices that do not address important perioperative management strategies for this ever-growing patient population. It is no longer satisfactory to simply place a magnet over an implanted device during surgery and assume that this action protects the patient from harm due to electromagnetic interference from inappropriate device function. This AANA Journal course serves as a concise review of basic device function, the sources and effects of electromagnetic interference in the operative setting, and patient management recommendations from current literature.

  17. Lifshitz effects on holographic p-wave superfluid

    Directory of Open Access Journals (Sweden)

    Ya-Bo Wu

    2015-02-01

    Full Text Available In the probe limit, we numerically build a holographic p-wave superfluid model in the four-dimensional Lifshitz black hole coupled to a Maxwell-complex vector field. We observe the rich phase structure and find that the Lifshitz dynamical exponent z contributes evidently to the effective mass of the matter field and dimension of the gravitational background. Concretely, we obtain that the Cave of Winds appeared only in the five-dimensional anti-de Sitter (AdS spacetime, and the increasing z hinders not only the condensate but also the appearance of the first-order phase transition. Furthermore, our results agree with the Ginzburg–Landau results near the critical temperature. In addition, the previous AdS superfluid model is generalized to the Lifshitz spacetime. Keywords: Gauge/gravity duality, Holographic superconductor, Lifshitz black hole, Maxwell-complex vector field

  18. P Wave Duration And Dispersion In Patients With Hyperthyroidism And The Short-term Effects Of Antithyroid Treatment

    OpenAIRE

    Unal Guntekin; Yilmaz Gunes; Hakki Simsek; Mustafa Tuncer; Sevket Arslan

    2009-01-01

    Background: Prolonged P wave duration and P wave dispersion (PWD) have been associated with an increased risk for atrial fibrillation (AF). Hyperthytodism is a frequent cause of atrial fibrillation (AF). Methods: Forty-two patients with newly diagnosed overt hyperthyroidism and 20 healthy people were enrolled in the study. Transthoracic echocardiography, 12 lead surface ECG and thyroid hormone levels were studied at the time of enrollment and after achievement of euthyroid state with propylth...

  19. POPDC1S201F causes muscular dystrophy and arrhythmia by affecting protein trafficking

    Science.gov (United States)

    Schindler, Roland F.R.; Scotton, Chiara; Zhang, Jianguo; Passarelli, Chiara; Ortiz-Bonnin, Beatriz; Simrick, Subreena; Schwerte, Thorsten; Poon, Kar-Lai; Fang, Mingyan; Rinné, Susanne; Froese, Alexander; Nikolaev, Viacheslav O.; Grunert, Christiane; Müller, Thomas; Tasca, Giorgio; Sarathchandra, Padmini; Drago, Fabrizio; Dallapiccola, Bruno; Rapezzi, Claudio; Arbustini, Eloisa; Di Raimo, Francesca Romana; Neri, Marcella; Selvatici, Rita; Gualandi, Francesca; Fattori, Fabiana; Pietrangelo, Antonello; Li, Wenyan; Jiang, Hui; Xu, Xun; Bertini, Enrico; Decher, Niels; Wang, Jun; Brand, Thomas; Ferlini, Alessandra

    2015-01-01

    The Popeye domain–containing 1 (POPDC1) gene encodes a plasma membrane–localized cAMP-binding protein that is abundantly expressed in striated muscle. In animal models, POPDC1 is an essential regulator of structure and function of cardiac and skeletal muscle; however, POPDC1 mutations have not been associated with human cardiac and muscular diseases. Here, we have described a homozygous missense variant (c.602C>T, p.S201F) in POPDC1, identified by whole-exome sequencing, in a family of 4 with cardiac arrhythmia and limb-girdle muscular dystrophy (LGMD). This allele was absent in known databases and segregated with the pathological phenotype in this family. We did not find the allele in a further screen of 104 patients with a similar phenotype, suggesting this mutation to be family specific. Compared with WT protein, POPDC1S201F displayed a 50% reduction in cAMP affinity, and in skeletal muscle from patients, both POPDC1S201F and WT POPDC2 displayed impaired membrane trafficking. Forced expression of POPDC1S201F in a murine cardiac muscle cell line (HL-1) increased hyperpolarization and upstroke velocity of the action potential. In zebrafish, expression of the homologous mutation (popdc1S191F) caused heart and skeletal muscle phenotypes that resembled those observed in patients. Our study therefore identifies POPDC1 as a disease gene causing a very rare autosomal recessive cardiac arrhythmia and LGMD, expanding the genetic causes of this heterogeneous group of inherited rare diseases. PMID:26642364

  20. Synthetic seismograms - II. Synthesis of amplitude spectra and seismograms of P waves from underground nuclear explosions

    International Nuclear Information System (INIS)

    Banghar, A.R.

    1980-01-01

    As a part of programme of seismic detection of underground nuclear explosions, step by step variations in the amplitude spectra and waveforms of P wave signal, as it propagates from source to receiver region, are investigated. Influences on the amplitude spectra and waveforms of teleseismic p waves due to : (1) variation in the shape of reduced displacement potential, (2) variation of mantle Q values, (3) change in depth, (4) various yields, (5) spalling, and (6) variation of crustal structure at source as well as at receiver are studied. The results show that for a yield of 85 kilotons, the time structure of seismograms is nearly same for four types of reduced displacement potentials considered here. The duration of waveforms is affected both by crustal structure at source as well as due to spalling. In general, effect of receiver crust on seismograms is found to be minor. Synthesized and observed P wave seismograms for Longshot, Milrow and Cannikin underground nuclear explosions are computed at various seismometer array stations of the UKAEA. Computed seismograms compare well with the recorded ones. It is seen that: (1) overburden P wave velocity inferred from seismograms is less as compared to its value obtained from on-site measurements, and (2) the source function, the source crust transfer function, the mantle transfer function and the spalling function are the most important factors that influence shaping of spectra and seismograms. (M.G.B.)

  1. P-wave velocity changes in freezing hard low-porosity rocks: a laboratory-based time-average model

    Directory of Open Access Journals (Sweden)

    D. Draebing

    2012-10-01

    Full Text Available P-wave refraction seismics is a key method in permafrost research but its applicability to low-porosity rocks, which constitute alpine rock walls, has been denied in prior studies. These studies explain p-wave velocity changes in freezing rocks exclusively due to changing velocities of pore infill, i.e. water, air and ice. In existing models, no significant velocity increase is expected for low-porosity bedrock. We postulate, that mixing laws apply for high-porosity rocks, but freezing in confined space in low-porosity bedrock also alters physical rock matrix properties. In the laboratory, we measured p-wave velocities of 22 decimetre-large low-porosity (< 10% metamorphic, magmatic and sedimentary rock samples from permafrost sites with a natural texture (> 100 micro-fissures from 25 °C to −15 °C in 0.3 °C increments close to the freezing point. When freezing, p-wave velocity increases by 11–166% perpendicular to cleavage/bedding and equivalent to a matrix velocity increase from 11–200% coincident to an anisotropy decrease in most samples. The expansion of rigid bedrock upon freezing is restricted and ice pressure will increase matrix velocity and decrease anisotropy while changing velocities of the pore infill are insignificant. Here, we present a modified Timur's two-phase-equation implementing changes in matrix velocity dependent on lithology and demonstrate the general applicability of refraction seismics to differentiate frozen and unfrozen low-porosity bedrock.

  2. Dental caries, periodontal disease, and cardiac arrhythmias in community-dwelling older persons aged 80 and older: is there a link?

    DEFF Research Database (Denmark)

    Holm-Pedersen, Poul; Avlund, Kirsten; Morse, Douglas E

    2005-01-01

    lesions had 2.8 times higher odds (95% confidence interval=1.1-7.0) of arrhythmia than persons without active coronal caries, but there was no greater risk for persons with three or more coronal caries lesions. There was no association between periodontal disease and arrhythmia. CONCLUSION: The findings......OBJECTIVES: To examine whether caries or periodontitis is associated with cardiac arrhythmias in community-dwelling people aged 80 and older. SETTING: Urban, community-based population in Stockholm, Sweden. DESIGN: Cross-sectional. PARTICIPANTS: Eligible persons were identified through...... by a physician or the Stockholm Inpatient Register. Active root caries, active coronal caries, and periodontitis were assessed using previously defined National Institute of Dental and Craniofacial Research diagnostic criteria. RESULTS: The primary finding of the multivariate logistic regression analysis...

  3. New results on the Roper resonance and the P-11 partial wave

    NARCIS (Netherlands)

    Sarantsev, A. V.; Fuchs, M.; Kotulla, M.; Thoma, U.; Ahrens, J.; Annand, J. R. M.; Anisovich, A. V.; Anton, G.; Bantes, R.; Bartholomy, O.; Beck, R.; Beloglazov, Yu.; Castelijns, R.; Crede, V.; Ehmanns, A.; Ernst, J.; Fabry, I.; Flemming, H.; Foesel, A.; Funke, Chr.; Gothe, R.; Gridnev, A.; Gutz, E.; Hoeffgen, St.; Horn, I.; Hoessl, J.; Hornidge, D.; Janssen, S.; Junkersfeld, J.; Kalinowsky, H.; Klein, F.; Klempt, E.; Koch, H.; Konrad, M.; Kopf, B.; Krusche, B.; Langheinrich, J.; Loehner, H.; Lopatin, I.; Lotz, J.; McGeorge, J. C.; MacGregor, I. J. D.; Matthaey, H.; Menze, D.; Messchendorp, J. G.; Metag, V.; Nikonov, V. A.; Novinski, D.; Novotny, R.; Ostrick, M.; van Pee, H.; Pfeiffer, M.; Radkov, A.; Rosner, G.; Rost, M.; Schmidt, C.; Schoch, B.; Suft, G.; Sumachev, V.; Szczepanek, T.; Walther, D.; Watts, D. P.; Weinheimer, Chr.

    2008-01-01

    Properties of the Roper resonance, the first scalar excitation of the nucleon, are determined. Pole positions and residues of the P-11 partial wave are studied in a combined analysis of pion- and photo-induced reactions. We find the Roper pole at {(1371 +/- 7) - i(92 +/- 10)} MeV and an elasticity

  4. Arrhythmia Mechanism and Scaling Effect on the Spectral Properties of Electroanatomical Maps With Manifold Harmonics.

    Science.gov (United States)

    Sanroman-Junquera, Margarita; Mora-Jimenez, Inmaculada; Garcia-Alberola, Arcadio; Caamano, Antonio J; Trenor, Beatriz; Rojo-Alvarez, Jose L

    2018-04-01

    Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysiological studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms.

  5. hERG trafficking inhibition in drug-induced lethal cardiac arrhythmia.

    Science.gov (United States)

    Nogawa, Hisashi; Kawai, Tomoyuki

    2014-10-15

    Acquired long QT syndrome induced by non-cardiovascular drugs can cause lethal cardiac arrhythmia called torsades de points and is a significant problem in drug development. The prolongation of QT interval and cardiac action potential duration are mainly due to reduced physiological function of the rapidly activating voltage-dependent potassium channels encoded by human ether-a-go-go-related gene (hERG). Structurally diverse groups of drugs are known to directly inhibit hERG channel conductance. Therefore, the ability of acute hERG inhibition is routinely assessed at the preclinical stages in pharmaceutical testing. Recent findings indicated that chronic treatment with various drugs not only inhibits hERG channels but also decreases hERG channel expression in the plasma membrane of cardiomyocytes, which has become another concern in safety pharmacology. The mechanisms involve the disruption of hERG trafficking to the surface membrane or the acceleration of hERG protein degradation. From this perspective, we present a brief overview of mechanisms of drug-induced trafficking inhibition and pathological regulation. Understanding of drug-induced hERG trafficking inhibition may provide new strategies for predicting drug-induced QT prolongation and lethal cardiac arrhythmia in pharmaceutical drug development. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Elastic Wave-equation Reflection Traveltime Inversion Using Dynamic Warping and Wave Mode Decomposition

    KAUST Repository

    Wang, T.

    2017-05-26

    Elastic full waveform inversion (EFWI) provides high-resolution parameter estimation of the subsurface but requires good initial guess of the true model. The traveltime inversion only minimizes traveltime misfits which are more sensitive and linearly related to the low-wavenumber model perturbation. Therefore, building initial P and S wave velocity models for EFWI by using elastic wave-equation reflections traveltime inversion (WERTI) would be effective and robust, especially for the deeper part. In order to distinguish the reflection travletimes of P or S-waves in elastic media, we decompose the surface multicomponent data into vector P- and S-wave seismogram. We utilize the dynamic image warping to extract the reflected P- or S-wave traveltimes. The P-wave velocity are first inverted using P-wave traveltime followed by the S-wave velocity inversion with S-wave traveltime, during which the wave mode decomposition is applied to the gradients calculation. Synthetic example on the Sigbee2A model proves the validity of our method for recovering the long wavelength components of the model.

  7. P and S wave Coda Calibration in Central Asia and South Korea

    Science.gov (United States)

    Kim, D.; Mayeda, K.; Gok, R.; Barno, J.; Roman-Nieves, J. I.

    2017-12-01

    Empirically derived coda source spectra provide unbiased, absolute moment magnitude (Mw) estimates for events that are normally too small for accurate long-period waveform modeling. In this study, we obtain coda-derived source spectra using data from Central Asia (Kyrgyzstan networks - KN and KR, and Tajikistan - TJ) and South Korea (Korea Meteorological Administration, KMA). We used a recently developed coda calibration module of Seismic WaveForm Tool (SWFT). Seismic activities during this recording period include the recent Gyeongju earthquake of Mw=5.3 and its aftershocks, two nuclear explosions from 2009 and 2013 in North Korea, and a small number of construction and mining-related explosions. For calibration, we calculated synthetic coda envelopes for both P and S waves based on a simple analytic expression that fits the observed narrowband filtered envelopes using the method outlined in Mayeda et al. (2003). To provide an absolute scale of the resulting source spectra, path and site corrections are applied using independent spectral constraints (e.g., Mw and stress drop) from three Kyrgyzstan events and the largest events of the Gyeongju sequence in Central Asia and South Korea, respectively. In spite of major tectonic differences, stable source spectra were obtained in both regions. We validated the resulting spectra by comparing the ratio of raw envelopes and source spectra from calibrated envelopes. Spectral shapes of earthquakes and explosions show different patterns in both regions. We also find (1) the source spectra derived from S-coda is more robust than that from the P-coda at low frequencies; (2) unlike earthquake events, the source spectra of explosions have a large disagreement between P and S waves; and (3) similarity is observed between 2016 Gyeongju and 2011 Virginia earthquake sequence in the eastern U.S.

  8. Exercise-induced ventricular arrhythmias and vagal dysfunction in Chagas disease patients with no apparent cardiac involvement

    Directory of Open Access Journals (Sweden)

    Henrique Silveira Costa

    2015-04-01

    Full Text Available INTRODUCTION : Exercise-induced ventricular arrhythmia (EIVA and autonomic imbalance are considered as early markers of heart disease in Chagas disease (ChD patients. The objective of the present study was to verify the differences in the occurrence of EIVA and autonomic maneuver indexes between healthy individuals and ChD patients with no apparent cardiac involvement. METHODS : A total of 75 ChD patients with no apparent cardiac involvement, aged 44.7 (8.5 years, and 38 healthy individuals, aged 44.0 (9.2 years, were evaluated using echocardiography, symptom-limited treadmill exercise testing and autonomic function tests. RESULTS : The occurrence of EIVA was higher in the chagasic group (48% than in the control group (23.7% during both the effort and the recovery phases. Frequent ventricular contractions occurred only in the patient group. Additionally, the respiratory sinus arrhythmia index was significantly lower in the chagasic individuals compared with the control group. CONCLUSIONS : ChD patients with no apparent cardiac involvement had a higher frequency of EIVA as well as more vagal dysfunction by respiratory sinus arrhythmia. These results suggest that even when asymptomatic, ChD patients possess important arrhythmogenic substrates and subclinical disease.

  9. Noninvasive cardiac activation imaging of ventricular arrhythmias during drug-induced QT prolongation in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; Zhou, Zhaoye; He, Bin

    2013-10-01

    Imaging myocardial activation from noninvasive body surface potentials promises to aid in both cardiovascular research and clinical medicine. To investigate the ability of a noninvasive 3-dimensional cardiac electrical imaging technique for characterizing the activation patterns of dynamically changing ventricular arrhythmias during drug-induced QT prolongation in rabbits. Simultaneous body surface potential mapping and 3-dimensional intracardiac mapping were performed in a closed-chest condition in 8 rabbits. Data analysis was performed on premature ventricular complexes, couplets, and torsades de pointes (TdP) induced during intravenous administration of clofilium and phenylephrine with combinations of various infusion rates. The drug infusion led to a significant increase in the QT interval (from 175 ± 7 to 274 ± 31 ms) and rate-corrected QT interval (from 183 ± 5 to 262 ± 21 ms) during the first dose cycle. All the ectopic beats initiated by a focal activation pattern. The initial beat of TdPs arose at the focal site, whereas the subsequent beats were due to focal activity from different sites or 2 competing focal sites. The imaged results captured the dynamic shift of activation patterns and were in good correlation with the simultaneous measurements, with a correlation coefficient of 0.65 ± 0.02 averaged over 111 ectopic beats. Sites of initial activation were localized to be ~5 mm from the directly measured initiation sites. The 3-dimensional cardiac electrical imaging technique could localize the origin of activation and image activation sequence of TdP during QT prolongation induced by clofilium and phenylephrine in rabbits. It offers the potential to noninvasively investigate the proarrhythmic effects of drug infusion and assess the mechanisms of arrhythmias on a beat-to-beat basis. © 2013 Heart Rhythm Society. All rights reserved.

  10. Design of a GaP/Si composite waveguide for CW terahertz wave generation via difference frequency mixing.

    Science.gov (United States)

    Saito, Kyosuke; Tanabe, Tadao; Oyama, Yutaka

    2014-06-10

    We design a GaP/Si composite waveguide to achieve efficient terahertz (THz) wave generation under collinear phase-matched difference frequency mixing (DFM) between near-infrared light sources. This waveguide structure provides a strong mode confinement of both near-infrared sources and THz wave, resulting in an efficient mode overlapping. The numerical results show that the waveguide can produce guided THz wave (5.93 THz) with a power conversion efficiency of 6.6×10(-4)  W(-1). This value is larger than previously obtained with the bulk GaP crystal: 0.5×10(-9)  W(-1) [J. Lightwave Technol.27, 3057 (2009)]. Our proposed composite waveguide can be achieved by bridging the telecom wavelength and THz frequency region.

  11. Cardiac Resynchronization Therapy Defibrillator Treatment in a Child with Heart Failure and Ventricular Arrhythmia

    Directory of Open Access Journals (Sweden)

    Hak Ju Kim

    2016-08-01

    Full Text Available Cardiac resynchronization therapy (CRT is a new treatment for refractory heart failure. However, most patients with heart failure treated with CRT are adults, middle-aged or older with idiopathic or ischemic dilated cardiomyopathy. We treated a 12-year-old boy, who was transferred after cardiac arrest, with dilated cardiomyopathy, left bundle-branch block, and ventricular tachycardia. We performed cardiac resynchronization therapy with a defibrillator (CRT-D. After CRT-D, left ventricular ejection fraction improved from 22% to 4 4% a ssessed by e chocardiog ram 1 year p ostoperatively. On e lectrocardiog ram, Q RS d uration was shortened from 206 to 144 ms. The patient’s clinical symptoms also improved. For pediatric patients with refractory heart failure and ventricular arrhythmia, CRT-D could be indicated as an effective therapeutic option.

  12. Exploration of auditory P50 gating in schizophrenia by way of difference waves

    DEFF Research Database (Denmark)

    Arnfred, Sidse M

    2006-01-01

    potentials but here this method along with low frequency filtering is applied exploratory on auditory P50 gating data, previously analyzed in the standard format (reported in Am J Psychiatry 2003, 160:2236-8). The exploration was motivated by the observation during visual peak detection that the AEP waveform......Electroencephalographic measures of information processing encompass both mid-latency evoked potentials like the pre-attentive auditory P50 potential and a host of later more cognitive components like P300 and N400.Difference waves have mostly been employed in studies of later event related...

  13. Nucleon-deuteron breakup quantities calculated with separable interactions including tensor forces and P-wave interactions

    International Nuclear Information System (INIS)

    Bruinsma, J.; Wageningen, R. van

    1977-01-01

    Nucleon-deuteron breakup calculations at a nucleon bombarding energy of 22.7 MeV have been performed with separable interactions including a tensor force and P-wave interactions. Differential cross sections and a selection of polarization quantities have been computed for special regions of the phase space. The influence of a tensor force and P-wave interactions on the differential cross section is of the order of 20%. Large discrepancies between theory and experiment occur for the vector analyzing powers, both for the kinematically complete and for the incomplete situation. The calculations show that there are kinematical situations in which the differential cross sections and the tensor analyzing powers are sufficiently large to make measurements feasible. (Auth.)

  14. Nondestructive evaluation of differently doped InP wafers by time-resolved four-wave mixing technique

    International Nuclear Information System (INIS)

    Kadys, A.; Sudzius, M.; Jarasiunas, K.; Mao Luhong; Sun Niefeng

    2006-01-01

    Photoelectric properties of semi-insulating, differently doped, and undoped indium phosphide wafers, grown by the liquid encapsulation Czochralski method, have been investigated by time-resolved picosecond four-wave mixing technique. Deep defect related carrier generation, recombination, and transport properties were investigated experimentally by measuring four-wave mixing kinetics and exposure characteristics. The presence of deep donor states in undoped InP was confirmed by a pronounced effect of a space charge electric field to carrier transport. On the other hand, the recharging dynamics of electrically active residual impurities was observed in undoped and Fe-doped InP through the process of efficient trapping of excess carriers. The bipolar diffusion coefficients and mobilities were determined for the all wafers

  15. Derivation of site-specific relationships between hydraulic parameters and p-wave velocities based on hydraulic and seismic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brauchler, R.; Doetsch, J.; Dietrich, P.; Sauter, M.

    2012-01-10

    In this study, hydraulic and seismic tomographic measurements were used to derive a site-specific relationship between the geophysical parameter p-wave velocity and the hydraulic parameters, diffusivity and specific storage. Our field study includes diffusivity tomograms derived from hydraulic travel time tomography, specific storage tomograms, derived from hydraulic attenuation tomography, and p-wave velocity tomograms, derived from seismic tomography. The tomographic inversion was performed in all three cases with the SIRT (Simultaneous Iterative Reconstruction Technique) algorithm, using a ray tracing technique with curved trajectories. The experimental set-up was designed such that the p-wave velocity tomogram overlaps the hydraulic tomograms by half. The experiments were performed at a wellcharacterized sand and gravel aquifer, located in the Leine River valley near Göttingen, Germany. Access to the shallow subsurface was provided by direct-push technology. The high spatial resolution of hydraulic and seismic tomography was exploited to derive representative site-specific relationships between the hydraulic and geophysical parameters, based on the area where geophysical and hydraulic tests were performed. The transformation of the p-wave velocities into hydraulic properties was undertaken using a k-means cluster analysis. Results demonstrate that the combination of hydraulic and geophysical tomographic data is a promising approach to improve hydrogeophysical site characterization.

  16. Developing regionalized models of lithospheric thickness and velocity structure across Eurasia and the Middle East from jointly inverting P-wave and S-wave receiver functions with Rayleigh wave group and phase velocities

    Energy Technology Data Exchange (ETDEWEB)

    Julia, J; Nyblade, A; Hansen, S; Rodgers, A; Matzel, E

    2009-07-06

    In this project, we are developing models of lithospheric structure for a wide variety of tectonic regions throughout Eurasia and the Middle East by regionalizing 1D velocity models obtained by jointly inverting P-wave and S-wave receiver functions with Rayleigh wave group and phase velocities. We expect the regionalized velocity models will improve our ability to predict travel-times for local and regional phases, such as Pg, Pn, Sn and Lg, as well as travel-times for body-waves at upper mantle triplication distances in both seismic and aseismic regions of Eurasia and the Middle East. We anticipate the models will help inform and strengthen ongoing and future efforts within the NNSA labs to develop 3D velocity models for Eurasia and the Middle East, and will assist in obtaining model-based predictions where no empirical data are available and for improving locations from sparse networks using kriging. The codes needed to conduct the joint inversion of P-wave receiver functions (PRFs), S-wave receiver functions (SRFs), and dispersion velocities have already been assembled as part of ongoing research on lithospheric structure in Africa. The methodology has been tested with synthetic 'data' and case studies have been investigated with data collected at an open broadband stations in South Africa. PRFs constrain the size and S-P travel-time of seismic discontinuities in the crust and uppermost mantle, SRFs constrain the size and P-S travel-time of the lithosphere-asthenosphere boundary, and dispersion velocities constrain average S-wave velocity within frequency-dependent depth-ranges. Preliminary results show that the combination yields integrated 1D velocity models local to the recording station, where the discontinuities constrained by the receiver functions are superimposed to a background velocity model constrained by the dispersion velocities. In our first year of this project we will (i) generate 1D velocity models for open broadband seismic stations

  17. Effects of valsartan on ventricular arrhythmia induced by programmed electrical stimulation in rats with myocardial infarction

    Science.gov (United States)

    Jiao, Kun-Li; Li, Yi-Gang; Zhang, Peng-Pai; Chen, Ren-Hua; Yu, Yi

    2012-01-01

    Abstract The impact of angiotensin II receptor blockers (ARBs) on electrical remodelling after myocardial infarction (MI) remains unclear. The purpose of the present study was to evaluate the effect of valsartan on incidence of ventricular arrhythmia induced by programmed electrical stimulation (PES) and potential link to changes of myocardial connexins (Cx) 43 expression and distribution in MI rats. Fifty-nine rats were randomly divided into three groups: Sham (n = 20), MI (n = 20) and MI + Val (20 mg/kg/day per gavage, n = 19). After eight weeks, the incidence of PES-induced ventricular tachycardia (VT) and fibrillation (VF) was compared among groups. mRNA and protein expressions of Cx43, angiotensin II type 1 receptor (AT1R) in the LV border zone (BZ) and non-infarct zone (NIZ) were determined by real-time PCR and Western blot, respectively. Connexins 43 protein and collagen distribution were examined by immunohistochemistry in BZ and NIZ sections from MI hearts. Valsartan effectively improved the cardiac function, reduced the prolonged QTc (163.7 ± 3.7 msec. versus 177.8 ± 4.5 msec., P valsartan. The mRNA and protein expressions of Cx43 in BZ were significantly reduced after MI and up-regulated by valsartan. Increased collagen deposition and reduced Cx43 expression in BZ after MI could be partly attenuated by Valsartan. Valsartan reduced the incidence of PES-induced ventricular arrhythmia, this effect was possibly through modulating the myocardial AT1R and Cx43 expression. PMID:22128836

  18. Arrhythmia causes lipid accumulation and reduced glucose uptake.

    Science.gov (United States)

    Lenski, Matthias; Schleider, Gregor; Kohlhaas, Michael; Adrian, Lucas; Adam, Oliver; Tian, Qinghai; Kaestner, Lars; Lipp, Peter; Lehrke, Michael; Maack, Christoph; Böhm, Michael; Laufs, Ulrich

    2015-01-01

    Atrial fibrillation (AF) is characterized by irregular contractions of atrial cardiomyocytes and increased energy demand. The aim of this study was to characterize the influence of arrhythmia on glucose and fatty acid (FA) metabolism in cardiomyocytes, mice and human left atrial myocardium. Compared to regular pacing, irregular (pseudo-random variation at the same number of contractions/min) pacing of neonatal rat cardiomyocytes induced shorter action potential durations and effective refractory periods and increased diastolic [Ca(2+)]c. This was associated with the activation of Ca(2+)/calmodulin-dependent protein kinase II (CaMKII) and AMP-activated protein kinase (AMPK). Membrane expression of fatty acid translocase (FAT/CD36) and (14)C-palmitic acid uptake were augmented while membrane expression of glucose transporter subtype 4 (GLUT-4) as well as (3)H-glucose uptake were reduced. Inhibition of AMPK and CaMKII prevented these arrhythmia-induced metabolic changes. Similar alterations of FA metabolism were observed in a transgenic mouse model (RacET) for spontaneous AF. Consistent with these findings samples of left atrial myocardium of patients with AF compared to matched samples of patients with sinus rhythm showed up-regulation of CaMKII and AMPK and increased membrane expression of FAT/CD36, resulting in lipid accumulation. These changes of FA metabolism were accompanied by decreased membrane expression of GLUT-4, increased glycogen content and increased expression of the pro-apoptotic protein bax. Irregular pacing of cardiomyocytes increases diastolic [Ca(2+)]c and activation of CaMKII and AMPK resulting in lipid accumulation, reduced glucose uptake and increased glycogen synthesis. These metabolic changes are accompanied by an activation of pro-apoptotic signalling pathways.

  19. Application of perturbation theory to a P-wave eikonal equation in orthorhombic media

    KAUST Repository

    Stovas, Alexey

    2016-10-12

    The P-wave eikonal equation for orthorhombic (ORT) anisotropic media is a highly nonlinear partial differential equation requiring the solution of a sixth-order polynomial to obtain traveltimes, resulting in complex and time-consuming numerical solutions. To alleviate this complexity, we approximate the solution of this equation by applying a multiparametric perturbation approach. We also investigated the sensitivity of traveltime surfaces inORT mediawith respect to three anelliptic parameters. As a result, a simple and accurate P-wave traveltime approximation valid for ORT media was derived. Two different possible anelliptic parameterizations were compared. One of the parameterizations includes anelliptic parameters defined at zero offset: η1, η2, and ηxy. Another parameterization includes anelliptic parameters defined for all symmetry planes: η1, η2, and η3. The azimuthal behavior of sensitivity coefficients with different parameterizations was used to analyze the crosstalk between anelliptic parameters. © 2016 Society of Exploration Geophysicists.

  20. Flecainide Therapy Reduces Exercise-Induced Ventricular Arrhythmias in Patients With Catecholaminergic Polymorphic Ventricular Tachycardia

    NARCIS (Netherlands)

    van der Werf, Christian; Kannankeril, Prince J.; Sacher, Frederic; Krahn, Andrew D.; Viskin, Sami; Leenhardt, Antoine; Shimizu, Wataru; Sumitomo, Naokata; Fish, Frank A.; Bhuiyan, Zahurul A.; Willems, Albert R.; van der Veen, Maurits J.; Watanabe, Hiroshi; Laborderie, Julien; Haïssaguerre, Michel; Knollmann, Björn C.; Wilde, Arthur A. M.

    2011-01-01

    Objectives This study evaluated the efficacy and safety of flecainide in addition to conventional drug therapy in patients with catecholaminergic polymorphic ventricular tachycardia (CPVT). Background CPVT is an inherited arrhythmia syndrome caused by gene mutations that destabilize cardiac