WorldWideScience

Sample records for non-adhering electrode substrate

  1. Rhenium Alloys as Ductile Substrates for Diamond Thin-Film Electrodes.

    Science.gov (United States)

    Halpern, Jeffrey M; Martin, Heidi B

    2014-02-01

    Molybdenum-rhenium (Mo/Re) and tungsten-rhenium (W/Re) alloys were investigated as substrates for thin-film, polycrystalline boron-doped diamond electrodes. Traditional, carbide-forming metal substrates adhere strongly to diamond but lose their ductility during exposure to the high-temperature (1000°C) diamond, chemical vapor deposition environment. Boron-doped semi-metallic diamond was selectively deposited for up to 20 hours on one end of Mo/Re (47.5/52.5 wt.%) and W/Re (75/25 wt.%) alloy wires. Conformal diamond films on the alloys displayed grain sizes and Raman signatures similar to films grown on tungsten; in all cases, the morphology and Raman spectra were consistent with well-faceted, microcrystalline diamond with minimal sp 2 carbon content. Cyclic voltammograms of dopamine in phosphate-buffered saline (PBS) showed the wide window and low baseline current of high-quality diamond electrodes. In addition, the films showed consistently well-defined, dopamine electrochemical redox activity. The Mo/Re substrate regions that were uncoated but still exposed to the diamond-growth environment remained substantially more flexible than tungsten in a bend-to-fracture rotation test, bending to the test maximum of 90° and not fracturing. The W/Re substrates fractured after a 27° bend, and the tungsten fractured after a 21° bend. Brittle, transgranular cleavage fracture surfaces were observed for tungsten and W/Re. A tension-induced fracture of the Mo/Re after the prior bend test showed a dimple fracture with a visible ductile core. Overall, the Mo/Re and W/Re alloys were suitable substrates for diamond growth. The Mo/Re alloy remained significantly more ductile than traditional tungsten substrates after diamond growth, and thus may be an attractive metal substrate for more ductile, thin-film diamond electrodes.

  2. Method for adhering a coating to a substrate structure

    Science.gov (United States)

    Taxacher, Glenn Curtis; Crespo, Andres Garcia; Roberts, III, Herbert Chidsey

    2015-02-17

    A method for adhering a coating to a substrate structure comprises selecting a substrate structure having an outer surface oriented substantially parallel to a direction of radial stress, modifying the outer surface to provide a textured region having steps to adhere a coating thereto, and applying a coating to extend over at least a portion of the textured region, wherein the steps are oriented substantially perpendicular to the direction of radial stress to resist deformation of the coating relative to the substrate structure. A rotating component comprises a substrate structure having an outer surface oriented substantially parallel to a direction of radial stress. The outer surface defines a textured region having steps to adhere a coating thereto, and a coating extends over at least a portion of the textured region. The steps are oriented substantially perpendicular to the direction of radial stress to resist creep.

  3. Long Life Nickel Electrodes for Nickel-Hydrogen Cells: Fiber Substrates Nickel Electrodes

    Science.gov (United States)

    Rogers, Howard H.

    2000-01-01

    Samples of nickel fiber mat electrodes were investigated over a wide range of fiber diameters, electrode thickness, porosity and active material loading levels. Thickness' were 0.040, 0.060 and 0.080 inches for the plaque: fiber diameters were primarily 2, 4, and 8 micron and porosity was 85, 90, and 95%. Capacities of 3.5 in. diameter electrodes were determined in the flooded condition with both 26 and 31% potassium hydroxide solution. These capacity tests indicated that the highest capacities per unit weight were obtained at the 90% porosity level with a 4 micron diameter fiber plaque. It appeared that the thinner electrodes had somewhat better performance, consistent with sintered electrode history. Limited testing with two-positive-electrode boiler plate cells was also carried out. Considerable difficulty with constructing the cells was encountered with short circuits the major problem. Nevertheless, four cells were tested. The cell with 95% porosity electrodes failed during conditioning cycling due to high voltage during charge. Discharge showed that this cell had lost nearly all of its capacity. The other three cells after 20 conditioning cycles showed capacities consistent with the flooded capacities of the electrodes. Positive electrodes made from fiber substrates may well show a weight advantage of standard sintered electrodes, but need considerably more work to prove this statement. A major problem to be investigated is the lower strength of the substrate compared to standard sintered electrodes. Problems with welding of leads were significant and implications that the electrodes would expand more than sintered electrodes need to be investigated. Loading levels were lower than had been expected based on sintered electrode experiences and the lower loading led to lower capacity values. However, lower loading causes less expansion and contraction during cycling so that stress on the substrate is reduced.

  4. Improved stability of titanium based boron-doped chemical vapor deposited diamond thin-film electrode by modifying titanium substrate surface

    International Nuclear Information System (INIS)

    Lim, P.Y.; Lin, F.Y.; Shih, H.C.; Ralchenko, V.G.; Varnin, V.P.; Pleskov, Yu.V.; Hsu, S.F.; Chou, S.S.; Hsu, P.L.

    2008-01-01

    The film quality and electrochemical properties of BDD (boron-doped diamond) thin films grown by hot-filament chemical vapor deposition technique on titanium substrates that had been subjected to a range of pre-treatment processes were evaluated. The pre-roughened Ti-substrates are shown to support more adherent BDD films. It is evident that acid-etching the Ti-substrate involves surface hydrogenation that enhances nucleation and formation of diamond thereon. The prepared BDD film exhibits wide potential window and electrochemical reversibility. It also demonstrated a better long-term electrochemical stability based on the low variation in voltametric background current upon the exposing of the electrodes to repeated cycles of electrochemical metal deposition/stripping process

  5. Doped polymer electrodes for high performance ferroelectric capacitors on plastic substrates

    KAUST Repository

    Khan, M. A.

    2012-10-03

    Flexible ferroelectric capacitors with doped polymer electrodes have been fabricated on plastic substrates with performance as good as metal electrodes. The effect of doping on the morphology of polymer electrodes and its impact on device performance have been studied. Improved fatigue characteristics using doped and undoped poly (3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) electrodes versus metal electrodes are observed. It is shown that the polymer electrodes follow classical ferroelectric and dielectric responses, including series resistance effects. The improved device characteristics obtained using highly conducting doped PEDOT:PSS suggest that it may be used both as an electrode and as global interconnect for all-polymer transparent circuits on flexible substrates.

  6. Patient non-adherence: an interpretative phenomenological analysis.

    Science.gov (United States)

    Dalvi, Vidya; Mekoth, Nandakumar

    2017-04-18

    Purpose While interpretative phenomenological analysis (IPA) has been used in health psychology research, it has so far not been applied to seek deeper insights into the patients' experiences about treatment. The purpose of this paper is to address this gap by using IPA to understand patient non-adherence. Design/methodology/approach In total, 18 patients with chronic conditions seeking healthcare services in Goa and Karnataka, India, were selected by using the snowball sampling method. In-depth interviews were conducted face to face. A semi-structured questionnaire developed by the researchers was used to collect the data. IPA was used to explore the themes to predict patient non-adherence. Findings The study results indicate that economic factors, health system related factors, social factors and psychological factors impact patient non-adherence. Patient non-adherence includes medication non-adherence and lifestyle modification non-adherence. Research limitations/implications Being cross sectional in design, the results may not be as appropriate as the results derived from a longitudinal study given that non-adherence occurs over time. Practical implications Patient non-adherence is a global health issue. Multidisciplinary approach to enhance patient adherence to treatment should form part of public healthcare policy. Social implications Exploring the factors influencing patient non-adherence will help the health-care industry stakeholders to reduce healthcare cost and improve patient's quality of life. Originality/value Although there is extensive quantitative research on the prevalence of non-adherence, qualitative research is limited. This paper addresses this gap by using IPA to understand patient non-adherence and its factors and dimensions.

  7. Substrate-bound tyrosinase electrode using gold nanoparticles anchored to pyrroloquinoline quinone for a pesticide biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G.Y.; Kang, M.S.; Shim, J.; Moon, S.H. [Gwangju Inst. of Science and Technology (Korea, Republic of). Dept. of Environmental Science and Engineering

    2008-07-01

    Enzyme electrodes are now being considered for use in the detection of pesticides. However, the electrodes do not have the sensitivity to detect low concentration pesticides, and external substrates are needed to measure changes in enzyme activity. This study discussed a chemical species designed to mimic a substrate in the preparation of a tyrosinase (TYR) electrode for use without substrate standard solutions. Pyrroloquinolone quinone (PQQ) was integrated within the tyrosinase electrode and used as an assimilated substrate for measuring the pesticide. Gold (Au) nanoparticles were also used to detect low concentration pesticides. The TYR was immobilized on the PQQ-anchored Au nanoparticles by a covalent bond. The tethered PQQ was then reduced by obtaining 2-electrons from the electrode. The study showed that the substrate-bound enzyme electrode can be used to detect pesticide without a substrate standard solution through the immobilization of the enzyme and the substrate on the Au nanoparticles.

  8. Can human error theory explain non-adherence?

    Science.gov (United States)

    Barber, Nick; Safdar, A; Franklin, Bryoney D

    2005-08-01

    To apply human error theory to explain non-adherence and examine how well it fits. Patients who were taking chronic medication were telephoned and asked whether they had been adhering to their medicine, and if not the reasons were explored and analysed according to a human error theory. Of 105 patients, 87 were contacted by telephone and they took part in the study. Forty-two recalled being non-adherent, 17 of them in the last 7 days; 11 of the 42 were intentionally non-adherent. The errors could be described by human error theory, and it explained unintentional non-adherence well, however, the application of 'rules' was difficult when considering mistakes. The consideration of error producing conditions and latent failures also revealed useful contributing factors. Human error theory offers a new and valuable way of understanding non-adherence, and could inform interventions. However, the theory needs further development to explain intentional non-adherence.

  9. Fabrication, characterization and electrocatalytic application of a lead dioxide electrode with porous titanium substrate

    International Nuclear Information System (INIS)

    Zhang, Wenli; Kong, Haishen; Lin, Haibo; Lu, Haiyan; Huang, Weimin; Yin, Jian; Lin, Zheqi; Bao, Jinpeng

    2015-01-01

    In this study, PbO 2 electrode was prepared on porous Ti/SnO 2 –Sb 2 O 5 substrate (denoted as 3D-Ti/PbO 2 electrode), and its electrochemical properties were investigated in detail. The electrodeposition mechanism of 3D-Ti/PbO 2 electrode was investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscope (SEM) result showed that the 3D-Ti/PbO 2 electrode possessed porous structure when it was electrodeposited for time less than 30 min. The 3D-Ti/PbO 2 electrode prepared for 10 min had more active sites than the lead dioxide electrode electrodeposited on planar titanium substrate (denoted as 2D-Ti/PbO 2 electrode) and its electrochemical porosity is about 54%. The embedded structure between porous Ti/SnO 2 –Sb 2 O 5 substrate and PbO 2 coating increased the stability of 3D-Ti/PbO 2 electrode. The service life of 3D-Ti/PbO 2 electrode was about 350 h which was much longer than 2D-Ti/PbO 2 electrode. What's more, 3D-Ti/PbO 2 electrode had better electrocatalytic activity towards phenol degradation than 2D-Ti/PbO 2 electrode. - Highlights: • 3D-Ti/PbO 2 electrode was prepared on a porous titanium substrate. • The electrochemical active surface area was investigated. • The activity of 3D-Ti/PbO 2 electrode towards phenol oxidation was investigated. • 3D-Ti/PbO 2 electrode shows superior electrocatalytic activity.

  10. Non-adherence to topical treatments for actinic keratosis

    Directory of Open Access Journals (Sweden)

    Shergill B

    2013-12-01

    Full Text Available Bav Shergill,1 Simon Zokaie,2 Alison J Carr3 1Department of Dermatology, Brighton and Sussex University Hospitals, Elm Grove, Brighton, UK; 2Leo Pharma, Princes Risborough, 3Hamell, London, UK Background: There is limited information on the patterns of use, adherence rates, and factors that impact adherence with topical treatments for actinic keratosis (AK. Objectives: To establish patterns of use and adherence with topical treatments for AK and to identify treatment-related factors that impact on adherence. Methods: A community-based, cross-sectional study was performed using a standardized questionnaire completed online or via telephone interview. Patients were stratified according to the presence of AK lesions on the scalp and/or other extremities; and presence of scarring resulting from treatment. Results: This study included 305 patients with AK who were currently using a patient-applied topical therapy for AK or had used one within the previous 12 months. In total, 88% (n = 268/305 of patients were either non-adherent, non-persistent or both non-adherent and non-persistent to topical therapy. Duration of treatment was associated with increasing rates of non-adherence (adjusted odds ratio [OR]; for treatment durations greater than 4 weeks, 2.2, P < 0.01: 52% of patients were non-adherent with 3–4 week treatment duration; 69% of patients with 4–8 week treatment duration; and 71% of patients with 6–12 week treatment duration. There were similar increases in non-persistence with increasing treatment duration (adjusted OR; for treatment durations greater than 4 weeks, 2.1, P < 0.05. Conclusion: This study found high rates of non-adherence and non-persistence in patients with AK. Duration of treatment was a significant factor contributing to non-adherence and non-persistence to topical treatments. Patient-applied topical therapies that require less frequent application and have shorter treatment duration may be associated with improved

  11. Zinc hexacyanoferrate film as an effective protecting layer in two-step and one-step electropolymerization of pyrrole on zinc substrate

    Energy Technology Data Exchange (ETDEWEB)

    Pournaghi-Azar, M.H. [Electroanalytical Chemistry Laboratory, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)]. E-mail: pournaghiazar@tabrizu.ac.ir; Nahalparvari, H. [Electroanalytical Chemistry Laboratory, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2005-03-15

    The two-step and one-step electrosynthesis processes of polypyrrole (PPy) films on the zinc substrate are described. The two-step process includes (i) the zinc surface pretreatment with hexacyanoferrate ion in the aqueous medium in order to form a zinc hexacyanoferrate (ZnHCF) film non-blocking passive layer on the surface and with the view to prevent its reactivity and (ii) electropolymerization of pyrrole on the ZnHCF vertical bar Zn-modified electrode in aqueous pyrrole solution. In this context, both the non-electrolytic and electrolytic procedures were adapted, and the effect of some experimental conditions such as supporting electrolyte, pH and temperature of the solution at the zinc surface pretreatment step as well as pyrrole concentration and electrochemical techniques at the polymerization step was investigated. By optimizing the experimental conditions in both steps, we have obtained a homogeneous and strongly adherent PPy films on the zinc substrate. The one-step process is based on the use of an aqueous medium containing Fe(CN){sub 6}{sup 4-} and pyrrole. The ferrocyanide ion passivates the substrate by formation of ZnHCF film during the electropolymerization process of pyrrole and therefore makes it possible to obtain strongly adherent PPy films, with controlled thickness, either by cyclic voltammetry or by electrolysis at constant current or constant potential without any previously treatment of the zinc electrode surface. The polypyrrole films deposited on the zinc electrode were characterized by cyclic voltammetry and scanning electron microscopic (SEM) measurement.

  12. Zinc hexacyanoferrate film as an effective protecting layer in two-step and one-step electropolymerization of pyrrole on zinc substrate

    International Nuclear Information System (INIS)

    Pournaghi-Azar, M.H.; Nahalparvari, H.

    2005-01-01

    The two-step and one-step electrosynthesis processes of polypyrrole (PPy) films on the zinc substrate are described. The two-step process includes (i) the zinc surface pretreatment with hexacyanoferrate ion in the aqueous medium in order to form a zinc hexacyanoferrate (ZnHCF) film non-blocking passive layer on the surface and with the view to prevent its reactivity and (ii) electropolymerization of pyrrole on the ZnHCF vertical bar Zn-modified electrode in aqueous pyrrole solution. In this context, both the non-electrolytic and electrolytic procedures were adapted, and the effect of some experimental conditions such as supporting electrolyte, pH and temperature of the solution at the zinc surface pretreatment step as well as pyrrole concentration and electrochemical techniques at the polymerization step was investigated. By optimizing the experimental conditions in both steps, we have obtained a homogeneous and strongly adherent PPy films on the zinc substrate. The one-step process is based on the use of an aqueous medium containing Fe(CN) 6 4- and pyrrole. The ferrocyanide ion passivates the substrate by formation of ZnHCF film during the electropolymerization process of pyrrole and therefore makes it possible to obtain strongly adherent PPy films, with controlled thickness, either by cyclic voltammetry or by electrolysis at constant current or constant potential without any previously treatment of the zinc electrode surface. The polypyrrole films deposited on the zinc electrode were characterized by cyclic voltammetry and scanning electron microscopic (SEM) measurement

  13. Adherence of diamond films on refractory metal substrates for thermionic applications

    International Nuclear Information System (INIS)

    Tsao, B.H.; Ramalingam, M.L.; Adams, S.F.; Cloyd, J.S.

    1991-01-01

    Diamond films are currently being considered as electrical insulation material for application in the thermionic fuel element of a power producing nuclear reactor system. The function of the diamond insulator in this application is to electrically isolate the collector of each cell in the TFE from the coolant and outer sheath. Deposition of diamond films on plane surfaces of Si/SiO 2 have already been demonstrated to be quite effective. However, the diamond films on refractory metal surfaces tend to spall off in the process of deposition revealing an inefficient adherence characteristic between the film and the substrate. This paper is geared towards explaining this deficiency by way of selected experimentation and the use of analytical tools to predict uncertainties such as the mismatch in coefficient of expansion, micrographic study of the interface between the film and the substrate and X-ray diffraction spectra. The investigation of the adherence characteristics of several diamond films on Mo and Nb substrates revealed that there was an allowable stress that resulted in the formation of the critical thickness for the diamond film

  14. Identification of documented medication non-adherence in physician notes.

    Science.gov (United States)

    Turchin, Alexander; Wheeler, Holly I; Labreche, Matthew; Chu, Julia T; Pendergrass, Merri L; Einbinder, Jonathan S; Einbinder, Jonathan Seth

    2008-11-06

    Medication non-adherence is common and the physicians awareness of it may be an important factor in clinical decision making. Few sources of data on physician awareness of medication non-adherence are available. We have designed an algorithm to identify documentation of medication non-adherence in the text of physician notes. The algorithm recognizes eight semantic classes of documentation of medication non-adherence. We evaluated the algorithm against manual ratings of 200 randomly selected notes of hypertensive patients. The algorithm detected 89% of the notes with documented medication non-adherence with specificity of 84.7% and positive predictive value of 80.2%. In a larger dataset of 1,000 documents, notes that documented medication non-adherence were more likely to report significantly elevated systolic (15.3% vs. 9.0%; p = 0.002) and diastolic (4.1% vs. 1.9%; p = 0.03) blood pressure. This novel clinically validated tool expands the range of information on medication non-adherence available to researchers.

  15. A nonadhesive solid-gel electrode for a non-invasive brain–machine interface

    Directory of Open Access Journals (Sweden)

    Shigeru eToyama

    2012-07-01

    Full Text Available A non-invasive brain–machine interface (BMI or brain-computer interface (BCI is a technology for helping individuals with disabilities and utilizes neurophysiological signals from the brain to control external machines or computers without requiring surgery. However, when applying EEG methodology, users must place EEG electrodes on the scalp each time, and the development of easy-to-use electrodes for clinical use is required. In this study, we developed a conductive nonadhesive solid-gel electrode for practical non-invasive BMIs. We performed basic material testing, including examining the volume resistivity, viscoelasticity, and moisture-retention properties of the solid gel. Then, we compared the performance of the solid gel, a conventional paste, and an in-house metal pin-based electrode using impedance measurements and P300-BMI testing. The solid gel was observed to be conductive (volume resistivity 13.2 Ωcm and soft (complex modulus 105.4 kPa, and it remained wet for a prolonged period (>10 hours in a dry environment. Impedance measurements revealed that the impedance of the solid-gel-based and conventional paste-based electrodes was superior to that of the pin-based electrode. The EEG measurement suggested that the signals obtained with the solid-gel electrode were comparable to those with the conventional paste-based electrode. Moreover, the P300-BMI study suggested that systems using the solid-gel or pin-based electrodes were effective. One of the advantages of the solid gel is that it does not require cleaning after use, whereas the conventional paste adheres to the hair, which requires washing. Furthermore, the solid-gel electrode was not painful compared with a metal-pin electrode. Taken together, the results suggest that the solid-gel electrode worked well for practical BMIs and could be useful for bedridden patients such as those with amyotrophic lateral sclerosis.

  16. Method of electrode printing on one or more surfaces of a dielectric substrate

    KAUST Repository

    Neophytou, Marios

    2017-09-14

    Described herein is a method for printing electrodes surfaces of a dielectric substrate. Provided herein is a new method of depositing electrically conductive electrodes of any shape on flexible and/or rigid dielectric substrates/surfaces and devices so produced. In various embodiments, the devices can generate ionic wind, for example to remove dust or other debris or contaminants or to remove ice or humidity from a surface.

  17. Method of electrode printing on one or more surfaces of a dielectric substrate

    KAUST Repository

    Neophytou, Marios; Kirkus, Mindaugas; Lacoste, Deanna A.

    2017-01-01

    Described herein is a method for printing electrodes surfaces of a dielectric substrate. Provided herein is a new method of depositing electrically conductive electrodes of any shape on flexible and/or rigid dielectric substrates/surfaces and devices so produced. In various embodiments, the devices can generate ionic wind, for example to remove dust or other debris or contaminants or to remove ice or humidity from a surface.

  18. Primary non-adherence to prescribed medication in general practice

    DEFF Research Database (Denmark)

    Linnet, Kristján; Halldórsson, Matthías; Thengilsdóttir, Gudrún

    2013-01-01

    Primary non-adherence refers to the patient not redeeming a prescribed medication at some point during drug therapy. Research has mainly focused on secondary non-adherence. Prior to this study, the overall rate of primary non-adherence in general practice in Iceland was not known....

  19. Medication non-adherence and uncertainty

    DEFF Research Database (Denmark)

    Kriegbaum, Margit; Lau, Sofie Rosenlund

    2017-01-01

    BACKGROUND: Statins are widely prescribed to lower cardiovascular morbidity and mortality. However, statin non-adherence is very high. PURPOSE: The aim of this paper was to investigate reasons for stopping statin treatment in the general population and to study how aspects of information-seeking ......BACKGROUND: Statins are widely prescribed to lower cardiovascular morbidity and mortality. However, statin non-adherence is very high. PURPOSE: The aim of this paper was to investigate reasons for stopping statin treatment in the general population and to study how aspects of information......-seeking and processing is associated with statin non-adherence. METHODS: This study used a population survey on 3050 Danish residents aged 45-65 years. Reasons for statin discontinuation was studied among those who were previous statin users. The association between information seeking and processing and statin...... from information disseminated by media outlets. Side effects and fear of side effects should be addressed in clinical practice. Health care professionals should pay attention to emotional aspects of how information is disseminated and perceived by statin users....

  20. Predictors of medication non-adherence for vasculitis patients

    Science.gov (United States)

    Hogan, Susan L.; DeVellis, Robert F.

    2013-01-01

    The primary purpose of this article is to document whether demographic, clinical, regimen-related, intrapersonal, and interpersonal factors predict medication non-adherence for vasculitis patients. A secondary purpose is to explore whether adherence varies by medication type and whether patients experienced drug-related side effects. Vasculitis patients (n=228) completed online baseline and 3-month follow-up surveys. Demographic (age, gender, education, race, marital status, and insurance status), clinical (perceived vasculitis severity, disease duration, vasculitis type, and relapse/remission status), regimen-related (experience of side effects), intrapersonal (depressive symptoms), and interpersonal (adherence-related support from family and friends) factors were measured at baseline. Medication non-adherence was assessed at follow-up using the Vasculitis Self-Management Survey medication adherence sub-scale (α=0.89). Variables that significantly correlated (pvasculitis medication types, patients who experienced side effects were less adherent than patients who did not experience side effects. Multiple factors are associated with medication non-adherence for vasculitis patients. Providers should discuss medication adherence and drug-related side effects with vasculitis patients. Providers may want to particularly target younger patients and patients with clinical signs of depression. PMID:23314654

  1. High-resolution and high-conductive electrode fabrication on a low thermal resistance flexible substrate

    International Nuclear Information System (INIS)

    Kang, Bongchul; Kno, Jinsung; Yang, Minyang

    2011-01-01

    Processes based on the liquid-state pattern transfer, like inkjet printing, have critical limitations including low resolution and low electrical conductivity when fabricating electrodes on low thermal resistance flexible substrates such as polyethylene terephthalate (PET). Those are due to the nonlinear transfer mechanism and the limit of the sintering temperature. Although the laser direct curing (LDC) of metallic inks is an alternative process to improve the resolution, it is also associated with the disadvantages of causing thermal damage to the polymer substrate. This paper suggests the laser induced pattern adhesion transfer method to fabricate electrodes of both high electrical conductivity and high resolution on a PET substrate. First, solid patterns are cost-effectively created by the LDC of the organometallic silver ink on a glass that is optically and thermally stable. The solid patterns sintered on the glass are transferred to the PET substrate by the photo-thermally generated adhesion force of the substrate. Therefore, we achieved electrodes with a minimum line width of 10 µm and a specific resistance of 3.6 μΩcm on the PET substrate. The patterns also showed high mechanical reliability

  2. High-resolution and high-conductive electrode fabrication on a low thermal resistance flexible substrate

    Science.gov (United States)

    Kang, Bongchul; Kno, Jinsung; Yang, Minyang

    2011-07-01

    Processes based on the liquid-state pattern transfer, like inkjet printing, have critical limitations including low resolution and low electrical conductivity when fabricating electrodes on low thermal resistance flexible substrates such as polyethylene terephthalate (PET). Those are due to the nonlinear transfer mechanism and the limit of the sintering temperature. Although the laser direct curing (LDC) of metallic inks is an alternative process to improve the resolution, it is also associated with the disadvantages of causing thermal damage to the polymer substrate. This paper suggests the laser induced pattern adhesion transfer method to fabricate electrodes of both high electrical conductivity and high resolution on a PET substrate. First, solid patterns are cost-effectively created by the LDC of the organometallic silver ink on a glass that is optically and thermally stable. The solid patterns sintered on the glass are transferred to the PET substrate by the photo-thermally generated adhesion force of the substrate. Therefore, we achieved electrodes with a minimum line width of 10 µm and a specific resistance of 3.6 μΩcm on the PET substrate. The patterns also showed high mechanical reliability.

  3. Directional freezing for the cryopreservation of adherent mammalian cells on a substrate

    Science.gov (United States)

    Braslavsky, Ido

    2018-01-01

    Successfully cryopreserving cells adhered to a substrate would facilitate the growth of a vital confluent cell culture after thawing while dramatically shortening the post-thaw culturing time. Herein we propose a controlled slow cooling method combining initial directional freezing followed by gradual cooling down to -80°C for robust preservation of cell monolayers adherent to a substrate. Using computer controlled cryostages we examined the effect of cooling rates and dimethylsulfoxide (DMSO) concentration on cell survival and established an optimal cryopreservation protocol. Experimental results show the highest post-thawing viability for directional ice growth at a speed of 30 μm/sec (equivalent to freezing rate of 3.8°C/min), followed by gradual cooling of the sample with decreasing rate of 0.5°C/min. Efficient cryopreservation of three widely used epithelial cell lines: IEC-18, HeLa, and Caco-2, provides proof-of-concept support for this new freezing protocol applied to adherent cells. This method is highly reproducible, significantly increases the post-thaw cell viability and can be readily applied for cryopreservation of cellular cultures in microfluidic devices. PMID:29447224

  4. Predictors and outcomes of non-adherence in patients receiving maintenance hemodialysis.

    Science.gov (United States)

    Tohme, Fadi; Mor, Maria K; Pena-Polanco, Julio; Green, Jamie A; Fine, Michael J; Palevsky, Paul M; Weisbord, Steven D

    2017-08-01

    Predictors of and outcomes associated with non-adherent behavior among patients on chronic hemodialysis (HD) have been incompletely elucidated. We conducted a post hoc analysis of data from the SMILE trial to identify patient factors associated with non-adherence to dialysis-related treatments and the associations of non-adherence with clinical outcomes. We defined non-adherence as missed HD and abbreviated HD. We used negative binomial regression to model the associations of demographic and clinical factors with measures of non-adherence, and negative binomial and Cox regression to analyze the associations of non-adherence with hospitalizations and mortality, respectively. We followed 286 patients for up to 24 months. Factors independently associated with missing HD included Tuesday/Thursday/Saturday HD schedule [incident rate ratio (IRR) 1.85, p adherence to HD-related treatments, and independent associations of non-adherence with hospitalization and mortality. These findings should inform the development and implementation of interventions to improve adherence and reduce health resource utilization.

  5. System for integrated adherence monitoring: real-time non-adherence risk assessment in pediatric kidney transplantation.

    Science.gov (United States)

    Pai, Ahna L H; Rausch, Joseph; Tackett, Alayna; Marsolo, Keith; Drotar, Dennis; Goebel, Jens

    2012-06-01

    This study reports initial results of the development of the SIAM, a non-adherence risk assessment system for tacrolimus and sirolimus for the pediatric kidney transplant population. Forty-eight youths between 10 and 25 yr of age diagnosed with chronic kidney disease or a kidney transplant used an electronic pill bottle (EM; time stamps each bottle opening) to dispense their medication for at least 30 days or until their next clinic appointment. Youth also completed a self-report adherence measure, and standard deviations were calculated for the last four medication serum trough levels obtained for each patient. Estimation models were developed for each medication (i.e., SIAM(TACRO) and SIAM(SIRO) ) to assign weights to these clinically available adherence measures (self-report and trough levels) for the calculation of a non-adherence risk composite score. SIAM(TACRO) models included both self-report and tacrolimus trough levels and significantly predicted EM. For sirolimus, the model predictive of adherence as measured by EM consisted of the standard deviation of sirolimus trough levels only (SIAM(SIRO) ). Non-adherence risk can be effectively assessed using clinically available assessment tools. However, the best methods for using self-report and trough levels to predict non-adherence likely differ based on the medication for which adherence is being assessed. © 2012 John Wiley & Sons A/S.

  6. Selective DNA-Mediated Assembly of Gold Nanoparticles on Electroded Substrates

    Science.gov (United States)

    2008-06-01

    might use the Watson - Crick base-pairing of DNA as a means for ultrahigh-precision engineering is well- known.5,6 The idea is to use the highly specific...Selective DNA -Mediated Assembly of Gold Nanoparticles on Electroded Substrates K. E. Sapsford,†,‡,∇ D. Park,§ E. R. Goldman,‡ E. E. Foos,| S. A...electrodes via DNA hybridization. Protocols are demonstrated for maximizing selectivity and coverage using 15mers as the active binding agents. Detailed

  7. Co@MWNTs-Plastic: A novel electrode for NaBH4 oxidation

    International Nuclear Information System (INIS)

    Zhang, Dongming; Ye, Ke; Cao, Dianxue; Wang, Bin; Cheng, Kui; Li, Yiju; Wang, Guiling; Xu, Yang

    2015-01-01

    Highlights: • MP substrate was fabricated by adhering MWNTs on a piece of obsoleted plastic bag. • Co nano-thorns were prepared by a simple electrodeposition method on the MP surface. • MP owns a superior stability in strong alkaline environment. • CMP exhibits a high catalytic activity for NaBH 4 electrooxidation. • The possible mechanisms of NaBH 4 electrooxidation on CMP was discussed. - Abstract: A novel multi-walled carbon nanotubes (MWNTs)-Plastic (MP) substrate was first fabricated by adhering MWNTs on a piece of obsoleted plastic bag, and Co nano-thorns were subsequently prepared by a simple electrodeposition method on the MP surface. The morphology and phase structure of the as-prepared Co@MWNTs-Plastic (CMP) catalytic electrode are characterized by scanning electron microscopy, transmission electron microscopy and X-ray diffractometer. The catalytic activity of the CMP electrode for NaBH 4 electrooxidation is investigated by means of cyclic voltammetry and chronoamperometry. The employing of waste plastic bags reduces white pollution and the MP substrate exhibits superior stability in alkaline solution. The 3D CMP catalytic electrode owns a high electrochemical activity for NaBH 4 oxidation. Moreover, we discussed the possible mechanisms of NaBH 4 electrooxidation on the CMP

  8. Non-adherence in patients on peritoneal dialysis: a systematic review.

    Science.gov (United States)

    Griva, Konstadina; Lai, Alden Yuanhong; Lim, Haikel Asyraf; Yu, Zhenli; Foo, Marjorie Wai Yin; Newman, Stanton P

    2014-01-01

    It has been increasingly recognized that non-adherence is an important factor that determines the outcome of peritoneal dialysis (PD) therapy. There is therefore a need to establish the levels of non-adherence to different aspects of the PD regimen (dialysis procedures, medications, and dietary/fluid restrictions). A systematic review of peer-reviewed literature was performed in PubMed, PsycINFO and CINAHL databases using PRISMA guidelines in May 2013. Publications on non-adherence in PD were selected by two reviewers independently according to predefined inclusion and exclusion criteria. Relevant data on patient characteristics, measures, rates and factors associated with non-adherence were extracted. The quality of studies was also evaluated independently by two reviewers according to a revised version of the Effective Public Health Practice Project assessment tool. The search retrieved 204 studies, of which a total of 25 studies met inclusion criteria. Reported rates of non-adherence varied across studies: 2.6-53% for dialysis exchanges, 3.9-85% for medication, and 14.4-67% for diet/fluid restrictions. Methodological differences in measurement and definition of non-adherence underlie the observed variation. Factors associated with non-adherence that showed a degree of consistency were mostly socio-demographical, such as age, employment status, ethnicity, sex, and time period on PD treatment. Non-adherence to different dimensions of the dialysis regimen appears to be prevalent in PD patients. There is a need for further, high-quality research to explore these factors in more detail, with the aim of informing intervention designs to facilitate adherence in this patient population.

  9. Laser-Direct Writing of Silver Metal Electrodes on Transparent Flexible Substrates with High-Bonding Strength.

    Science.gov (United States)

    Zhou, Weiping; Bai, Shi; Ma, Ying; Ma, Delong; Hou, Tingxiu; Shi, Xiaomin; Hu, Anming

    2016-09-21

    We demonstrate a novel approach to rapidly fabricate conductive silver electrodes on transparent flexible substrates with high-bonding strength by laser-direct writing. A new type of silver ink composed of silver nitrate, sodium citrate, and polyvinylpyrrolidone (PVP) was prepared in this work. The role of PVP was elucidated for improving the quality of silver electrodes. Silver nanoparticles and sintered microstructures were simultaneously synthesized and patterned on a substrate using a focused 405 nm continuous wave laser. The writing was completed through the transparent flexible substrate with a programmed 2D scanning sample stage. Silver electrodes fabricated by this approach exhibit a remarkable bonding strength, which can withstand an adhesive tape test at least 50 times. After a 1500 time bending test, the resistance only increased 5.2%. With laser-induced in-situ synthesis, sintering, and simultaneous patterning of silver nanoparticles, this technology is promising for the facile fabrication of conducting electronic devices on flexible substrates.

  10. Non-adherence in patients on peritoneal dialysis: a systematic review.

    Directory of Open Access Journals (Sweden)

    Konstadina Griva

    Full Text Available BACKGROUND: It has been increasingly recognized that non-adherence is an important factor that determines the outcome of peritoneal dialysis (PD therapy. There is therefore a need to establish the levels of non-adherence to different aspects of the PD regimen (dialysis procedures, medications, and dietary/fluid restrictions. METHODS: A systematic review of peer-reviewed literature was performed in PubMed, PsycINFO and CINAHL databases using PRISMA guidelines in May 2013. Publications on non-adherence in PD were selected by two reviewers independently according to predefined inclusion and exclusion criteria. Relevant data on patient characteristics, measures, rates and factors associated with non-adherence were extracted. The quality of studies was also evaluated independently by two reviewers according to a revised version of the Effective Public Health Practice Project assessment tool. RESULTS: The search retrieved 204 studies, of which a total of 25 studies met inclusion criteria. Reported rates of non-adherence varied across studies: 2.6-53% for dialysis exchanges, 3.9-85% for medication, and 14.4-67% for diet/fluid restrictions. Methodological differences in measurement and definition of non-adherence underlie the observed variation. Factors associated with non-adherence that showed a degree of consistency were mostly socio-demographical, such as age, employment status, ethnicity, sex, and time period on PD treatment. CONCLUSION: Non-adherence to different dimensions of the dialysis regimen appears to be prevalent in PD patients. There is a need for further, high-quality research to explore these factors in more detail, with the aim of informing intervention designs to facilitate adherence in this patient population.

  11. Non-Adherence in Patients on Peritoneal Dialysis: A Systematic Review

    Science.gov (United States)

    Griva, Konstadina; Lai, Alden Yuanhong; Lim, Haikel Asyraf; Yu, Zhenli; Foo, Marjorie Wai Yin; Newman, Stanton P.

    2014-01-01

    Background It has been increasingly recognized that non-adherence is an important factor that determines the outcome of peritoneal dialysis (PD) therapy. There is therefore a need to establish the levels of non-adherence to different aspects of the PD regimen (dialysis procedures, medications, and dietary/fluid restrictions). Methods A systematic review of peer-reviewed literature was performed in PubMed, PsycINFO and CINAHL databases using PRISMA guidelines in May 2013. Publications on non-adherence in PD were selected by two reviewers independently according to predefined inclusion and exclusion criteria. Relevant data on patient characteristics, measures, rates and factors associated with non-adherence were extracted. The quality of studies was also evaluated independently by two reviewers according to a revised version of the Effective Public Health Practice Project assessment tool. Results The search retrieved 204 studies, of which a total of 25 studies met inclusion criteria. Reported rates of non-adherence varied across studies: 2.6–53% for dialysis exchanges, 3.9–85% for medication, and 14.4–67% for diet/fluid restrictions. Methodological differences in measurement and definition of non-adherence underlie the observed variation. Factors associated with non-adherence that showed a degree of consistency were mostly socio-demographical, such as age, employment status, ethnicity, sex, and time period on PD treatment. Conclusion Non-adherence to different dimensions of the dialysis regimen appears to be prevalent in PD patients. There is a need for further, high-quality research to explore these factors in more detail, with the aim of informing intervention designs to facilitate adherence in this patient population. PMID:24586478

  12. Novel transparent high-performance AgNWs/ZnO electrodes prepared on unconventional substrates with 3D structured surfaces

    Science.gov (United States)

    Lan, Wei; Yang, Zhiwei; Zhang, Yue; Wei, Yupeng; Wang, Pengxiang; Abas, Asim; Tang, Guomei; Zhang, Xuetao; Wang, Junya; Xie, Erqing

    2018-03-01

    With the development of optoelectronic devices with three-dimensional (3D) structured surfaces, transparent electrodes that can be deposited on non-plane substrates have become increasingly important. In this paper, novel transparent silver nanowire (AgNWs)/ZnO film electrodes were uniformly prepared on treated 3D glass and PET substrates with a combination of spin-coating and heat-welding. The AgNWs/ZnO films show a transmittance of ∼88% and a sheet resistance of ∼10 Ω/sq. They are comparable with commercial ITO films. Furthermore, only a small in-plane resistance variation of ∼1 Ω/sq was measured using four-point probe mapping in films with a 10 cm × 10 cm area. These results confirm that these novel film electrodes are very uniform. Both electrical resistance and optical transmittance of the films remain mostly intact after 1000 bending cycles and tape peeling-tests with 10 cycles. The films show high thermal stability for more than one month at 80 °C. The strategy provides a new route for the design and fabrication of optoelectronic devices with 3D structured surfaces.

  13. Non-adherence in seniors with dementia - a serious problem of routine clinical practice.

    Science.gov (United States)

    Lužný, Jan; Ivanová, Kateřina; Juríčková, Lubica

    2014-01-01

    Non-adherence to treatment in seniors with dementia is a frequent and potentially dangerous phenomenon in routine clinical practice which might lead to the inappropriate treatment of a patient, including the risk of intoxication. There might be different causes of non-adherence in patients with dementia: memory impairment, sensory disturbances, limitations in mobility, economical reasons limiting access to health care and medication. Non-adherence leads to serious clinical consequences as well as being a challenge for public health. to estimate prevalence of non-adherence in seniors with dementia and to study correlation between cognitive decline and non-adherence. Prospective study, analyzing medical records of seniors with dementia admitted to the inpatient psychogeriatric ward in the Kromeriz mental hospital from January 2010 to January 2011. Cognitive decline measured by MMSE, prevalence of Non-adherence to treatment and reasons for patient Non-adherence were studied. Non-adherence to any treatment was detected in 31.3% of seniors; memory impairment was the most common cause of non-adherence to treatment. In conclusion, non-adherence to treatment in the studied group of seniors with dementia correlates with the severity of cognitive impairment - a higher cognitive decline correlates with a higher risk of non-adherence to treatment.

  14. Development of a Flexible Non-Metal Electrode for Cell Stimulation and Recording

    Directory of Open Access Journals (Sweden)

    Cihun-Siyong Alex Gong

    2016-09-01

    Full Text Available This study presents a method of producing flexible electrodes for potentially simultaneously stimulating and measuring cellular signals in retinal cells. Currently, most multi-electrode applications rely primarily on etching, but the metals involved have a certain degree of brittleness, leaving them prone to cracking under prolonged pressure. This study proposes using silver chloride ink as a conductive metal, and polydimethysiloxane (PDMS as the substrate to provide electrodes with an increased degree of flexibility to allow them to bend. This structure is divided into the electrode layer made of PDMS and silver chloride ink, and a PDMS film coating layer. PDMS can be mixed in different proportions to modify the degree of rigidity. The proposed method involved three steps. The first segment entailed the manufacturing of the electrode, using silver chloride ink as the conductive material, and using computer software to define the electrode size and micro-engraving mechanisms to produce the electrode pattern. The resulting uniform PDMS pattern was then baked onto the model, and the flow channel was filled with the conductive material before air drying to produce the required electrode. In the second stage, we tested the electrode, using an impedance analyzer to measure electrode cyclic voltammetry and impedance. In the third phase, mechanical and biocompatibility tests were conducted to determine electrode properties. This study aims to produce a flexible, non-metallic sensing electrode which fits snugly for use in a range of measurement applications.

  15. Psychosocial Variables Associated with Immunosuppressive Medication Non-Adherence after Renal Transplantation

    Directory of Open Access Journals (Sweden)

    Jennifer Felicia Scheel

    2018-02-01

    Full Text Available IntroductionNon-adherence to immunosuppressive medication is regarded as an important factor for graft rejection and loss after successful renal transplantation. Yet, results on prevalence and relationship with psychosocial parameters are heterogeneous. The main aim of this study was to investigate the association of immunosuppressive medication non-adherence and psychosocial factors.MethodsIn 330 adult renal transplant recipients (≥12 months posttransplantation, health-related quality of life, depression, anxiety, social support, and subjective medication experiences were assessed, and their associations with patient-reported non-adherence was evaluated.Results33.6% of the patients admitted to be partially non-adherent. Non-adherence was associated with younger age, poorer social support, lower mental, but higher physical health-related quality of life. There was no association with depression and anxiety. However, high proportions of clinically relevant depression and anxiety symptoms were apparent in both adherent and non-adherent patients.ConclusionIn the posttransplant follow-up, kidney recipients with lower perceived social support, lower mental and higher physical health-related quality of life, and younger age can be regarded as a risk group for immunosuppressive medication non-adherence. In follow-up contacts with kidney transplant patients, physicians may pay attention to these factors. Furthermore, psychosocial interventions to optimize immunosuppressive medication adherence can be designed on the basis of this information, especially including subjectively perceived physical health-related quality of life and fostering social support seems to be of importance.

  16. Is Inconsistent Pre-treatment Bedtime Related to CPAP Non-Adherence?

    Science.gov (United States)

    Sawyer, Amy M.; King, Tonya S.; Sawyer, Douglas A.; Rizzo, Albert

    2014-01-01

    Lack of adherence to continuous positive airway pressure therapy (CPAP) limits the effectiveness of treatment of obstructive sleep apnea (OSA). We hypothesized that an irregular bedtime would be negatively related to regular use of CPAP treatment. If so, modifying bedtime schedule may address the persistent problem of inconsistent CPAP use in adults with OSA. In a prospective longitudinal study, we examined whether inconsistent self-reported bedtime before initiation of CPAP treatment, operationalized as bedtime variability, was (1) different among those adherent (≥ 4 hours per night) and non-adherent to CPAP treatment at one week and one month; and/or (2) was related to one-week and one-month CPAP use when other variables were accounted for. Consecutively-recruited newly-diagnosed OSA adults (N=79) completed sleep diaries prior to CPAP treatment. One-week and one-month objective CPAP use data were collected. Pre-treatment bedtime variability was different among CPAP non-adherers and adherers at one month and was a significant predictor of non-adherence at one month in multivariate analyses. The odds of one-month CPAP non-adherence were 3.5 times greater in those whose pre-treatment bedtimes varied by >75 minutes. Addressing sleep schedule prior to CPAP initiation may be an opportunity to improve CPAP adherence. PMID:25353159

  17. Efficient polymer solar cells on opaque substrates with a Laminated PEDOT : PSS top electrode

    NARCIS (Netherlands)

    Gupta, D.; Wienk, M.M.; Janssen, R.A.J.

    2013-01-01

    Solution processed polymer:fullerene solar cells on opaque substrates have been fabricated in conventional and inverted device configurations. Opaque substrates, such as insulated steel and metal covered glass, require a transparent conducting top electrode. We demonstrate that a high conducting

  18. Medicine non-adherence in kidney transplantation.

    Science.gov (United States)

    Williams, Allison Fiona; Manias, Elizabeth; Gaskin, Cadeyrn J; Crawford, Kimberley

    2014-06-01

    The increasing prevalence of chronic kidney disease, the relative shortage of kidney donors and the economic- and health-related costs of kidney transplant rejection make the prevention of adverse outcomes following transplantation a healthcare imperative. Although strict adherence to immunosuppressant medicine regimens is key to preventing kidney rejection, evidence suggests that adherence is sub-optimal. Strategies need to be developed to help recipients of kidney transplants adhere to their prescribed medicines. This review has found that a number of factors contribute to poor adherence, for example, attitudes towards medicine taking and forgetfulness. Few investigations have been conducted, however, on strategies to enhance medicine adherence in kidney transplant recipients. Strategies that may improve adherence include pharmacist-led interventions (incorporating counselling, medicine reviews and nephrologist liaison) and nurse-led interventions (involving collaboratively working with recipients to understand their routines and offering solutions to improve adherence). Strategies that have shown to have limited effectiveness include supplying medicines free of charge and providing feedback on a participant's medicine adherence without any educational or behavioural interventions. Transplantation is the preferred treatment option for people with end-stage kidney disease. Medicine non-adherence in kidney transplantation increases the risk of rejection, kidney loss and costly treatments. Interventions are needed to help the transplant recipient take all their medicines as prescribed to improve general well-being, medicine safety and reduce healthcare costs. © 2014 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  19. Reporting non-adherence in cluster randomised trials: A systematic review.

    Science.gov (United States)

    Agbla, Schadrac C; DiazOrdaz, Karla

    2018-06-01

    Treatment non-adherence in randomised trials refers to situations where some participants do not receive their allocated treatment as intended. For cluster randomised trials, where the unit of randomisation is a group of participants, non-adherence may occur at the cluster or individual level. When non-adherence occurs, randomisation no longer guarantees that the relationship between treatment receipt and outcome is unconfounded, and the power to detect the treatment effects in intention-to-treat analysis may be reduced. Thus, recording adherence and estimating the causal treatment effect adequately are of interest for clinical trials. To assess the extent of reporting of non-adherence issues in published cluster trials and to establish which methods are currently being used for addressing non-adherence, if any, and whether clustering is accounted for in these. We systematically reviewed 132 cluster trials published in English in 2011 previously identified through a search in PubMed. One-hundred and twenty three cluster trials were included in this systematic review. Non-adherence was reported in 56 cluster trials. Among these, 19 reported a treatment efficacy estimate: per protocol in 15 and as treated in 4. No study discussed the assumptions made by these methods, their plausibility or the sensitivity of the results to deviations from these assumptions. The year of publication of the cluster trials included in this review (2011) could be considered a limitation of this study; however, no new guidelines regarding the reporting and the handling of non-adherence for cluster trials have been published since. In addition, a single reviewer undertook the data extraction. To mitigate this, a second reviewer conducted a validation of the extraction process on 15 randomly selected reports. Agreement was satisfactory (93%). Despite the recommendations of the Consolidated Standards of Reporting Trials statement extension to cluster randomised trials, treatment adherence is

  20. Associations between patients' adherence and GPs' attitudes towards risk, statin therapy and management of non-adherence

    DEFF Research Database (Denmark)

    Barfoed, Benedicte L; Paulsen, Maja S; Christensen, Palle M

    2016-01-01

    BACKGROUND: Previous studies suggest that doctors' personal lifestyle, risk taking personality and beliefs about risk reducing therapies may affect their clinical decision-making. Whether such factors are further associated with patients' adherence with medication is largely unknown. OBJECTIVE...... statin treatment as important, how they managed non-adherence and whether non-adherence annoyed them. The Jackson Personality Inventory-revised was used to measure risk attitude. The GPs' responses were linked to register data on their patients' redeemed statin prescriptions. Mixed effect logistic...

  1. A systematic review of medication non-adherence in persons with dementia or cognitive impairment.

    Directory of Open Access Journals (Sweden)

    Daisy Smith

    Full Text Available Adherence to medication is vital for disease management while simultaneously reducing healthcare expenditure. Older persons with cognitive impairment (CI are at risk for non-adherence as cognitive processes are needed to manage medications. This systematic review focuses on the relationship between medication non-adherence and specific cognitive domains in persons with CI, and explores determinants of medication non-adherence. When available, relationships and factors are compared with cognitively intact populations.A seven database systematic search of studies published between 1 January 1949-31 December 2015 examining medication non-adherence in community dwelling persons with CI or dementia was conducted. Articles reporting medication non-adherence in people with CI or dementia in the community, with or without caregiver supports were eligible for inclusion. Papers reporting adherence to treatments in cognitively intact populations, populations from hospital or institutional settings, for non-prescribed medication or those describing dementia as a factor predicting medication non-adherence were excluded. Data on study and population characteristics, research design, data sources and analysis, specific cognitive domains, non-adherence prevalence, measurement of adherence, salient findings, factors associated with adherence and strategies to improve medication adherence were extracted. Study limitations included inconsistencies between data sources and definitions, resulting in a loss of fidelity in the value and comprehensiveness of data, as well as exclusion of non-pharmacological treatments and regimens.Fifteen studies met inclusion criteria. Adherence among CI subjects ranged from 10.7%-38% with better rates of adherence in non-CI individuals. Medication non-adherence definitions varied considerably. New-learning, memory and executive functioning were associated with improved adherence and formed the focus of most studies. Multiple factors

  2. Factors influencing non-adherence to tuberculosis treatment in Jepara, central Java, Indonesia.

    Science.gov (United States)

    Rondags, Angelique; Himawan, Ari Budi; Metsemakers, Job Fm; Kristina, Tri Nur

    2014-07-01

    One of the most serious problems for tuberculosis (TB) control is non-adherence to TB treatment. We studied the factors influencing non-adherence to TB treatment in Indonesia to inform TB treatment adherence strategies. We con- ducted semi-structured interviews with non-adherent patients and key informants in Jepara, Central Java, Indonesia. Three major themes were found in reasons for non-adherence to TB treatment: 1) knowledge about TB, 2) knowledge about TB treatment and 3) choosing and changing a health care treatment facility. Respondents had an inadequate knowledge about TB and its treatment. Feeling healthy and having financial problems were the most common reasons for TB treatment non-adherence. Respondents sought treatment from many different health care providers, and often changed the treatment facility location. TB treatment adherence might improve by providing better education about the disease and its treatment to those undergoing treatment. Providing information about where to receive treatment and that treatment is free could also improve compliance.

  3. NON-ADHERENCE IN SENIORS WITH DEMENTIA – A SERIOUS PROBLEM OF ROUTINE CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    Jan Lužný

    2014-01-01

    Full Text Available Background: Non-adherence to treatment in seniors with dementia is a frequent and potentially dangerous phenomenon in routine clinical practice which might lead to the inappropriate treatment of a patient, including the risk of intoxication. There might be different causes of non-adherence in patients with dementia: memory impairment, sensory disturbances, limitations in mobility, economical reasons limiting access to health care and medication. Non-adherence leads to serious clinical consequences as well as being a challenge for public health. Aim: to estimate prevalence of non-adherence in seniors with dementia and to study correlation between cognitive decline and non-adherence. Subjects and Methods: Prospective study, analyzing medical records of seniors with dementia admitted to the inpatient psychogeriatric ward in the Kromeriz mental hospital from January 2010 to January 2011. Cognitive decline measured by MMSE, prevalence of Non-adherence to treatment and reasons for patient Non-adherence were studied. Results: Non-adherence to any treatment was detected in 31.3% of seniors; memory impairment was the most common cause of non-adherence to treatment. Conclusion: In conclusion, non-adherence to treatment in the studied group of seniors with dementia correlates with the severity of cognitive impairment – a higher cognitive decline correlates with a higher risk of non-adherence to treatment.

  4. the art of avoiding non-adherence to antiretroviral treatment ...

    African Journals Online (AJOL)

    is better than cure' may therefore be applicable to the problem of non-adherence among patients on ART even more than in the management of chronic non- infectious diseases in which drug resistance is not an issue of concern. We therefore undertook an analysis of results from the adherence monitoring in our HIV care ...

  5. Wireless sEMG System with a Microneedle-Based High-Density Electrode Array on a Flexible Substrate.

    Science.gov (United States)

    Kim, Minjae; Gu, Gangyong; Cha, Kyoung Je; Kim, Dong Sung; Chung, Wan Kyun

    2017-12-30

    Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user's movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclosed in wet electrodes restricts spatial resolution, and these conventional bulky systems limit natural movements. In this paper, a microneedle-based high-density electrode array on a circuit integrated flexible substrate for sEMG is proposed. Microneedles allow for high spatial resolution without requiring conductive substances, and flexible substrates guarantee stable skin-electrode contact. Moreover, a compact signal processing system is integrated with the electrode array. Therefore, sEMG measurements are comfortable to the user and do not interfere with the movement. The system performance was demonstrated by testing its operation and estimating motion using a Gaussian mixture model-based, simplified 2D spatial pattern.

  6. Non-adherence to pharmacological treatment in schizophrenia and schizophrenia spectrum disorders

    DEFF Research Database (Denmark)

    Ljungdalh, P. M.

    2017-01-01

    Background and objectives The primary treatment for schizophrenia and schizophrenia-spectrum disorders is antipsychotic medication. One of the many public health challenges in mental illness, is to identify contributing factors to non-adherence to pharmacological treatment. The objective...... of this study was to perform an updated systematic review of risk factors for non-adherence to pharmacological treatment in schizophrenia in a European and American context. Methods The study was a systematic literature review of studies that included at least two measurements of pharmacological adherence...... of illness, alcohol or drug abuse and unspecified younger age. Conclusions The findings in this systematic literature review are consistent with previous reviews on non-adherence and schizophrenia. It stresses the methodological challenges in psychiatric adherence research and establishes the need for more...

  7. Non-permeable substrate carrier for electroplating

    Science.gov (United States)

    Abas, Emmanuel Chua; Chen, Chen-An; Ma, Diana Xiaobing; Ganti, Kalyana Bhargava

    2012-11-27

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier comprises a non-conductive carrier body on which the substrates are to be held. Electrically-conductive lines are embedded within the carrier body, and a plurality of contact clips are coupled to the electrically-conductive lines embedded within the carrier body. The contact clips hold the substrates in place and electrically couple the substrates to the electrically-conductive lines. The non-conductive carrier body is continuous so as to be impermeable to flow of electroplating solution through the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

  8. Experiences of non-adherence to Internet-delivered cognitive behavior therapy: A qualitative study

    Directory of Open Access Journals (Sweden)

    Olof Johansson

    2015-05-01

    Full Text Available Many trials on Internet-delivered psychological treatments have had problems with nonadherence, but not much is known about the subjective reasons for non-adhering. The aim of this study was to explore participants' experiences of non-adherence to Internet-delivered psychological treatment. Grounded theory was used to analyze data from seven in-depth interviews with persons who had non-adhered to a study on Internet-delivered cognitive behavioral therapy for generalized anxiety disorder. The process of non-adherence is described as an interaction between patient factors and treatment factors. A working model theory was generated to illustrate the experience of nonadherence. The model describes a process where treatment features such as workload, text-content complexity and treatment process don't match personal prerequisites regarding daily routines, perceived language skills and treatment expectations respectively, resulting in the decision to nonadhere. Negative effects were also stated as a reason for non-adherence. Several common strategies used for increasing adherence to Internet-delivered therapy in general are by these non-completers regarded as factors directly related to their reason for non-adherence.

  9. The Impact of Health Care Appointment Non-Adherence on Graft Outcomes in Kidney Transplantation.

    Science.gov (United States)

    Taber, David J; Fleming, James N; Fominaya, Cory E; Gebregziabher, Mulugeta; Hunt, Kelly J; Srinivas, Titte R; Baliga, Prabhakar K; McGillicuddy, John W; Egede, Leonard E

    2017-01-01

    Non-adherence to medication is a well-studied and known cause of late allograft loss, but it is difficult to measure and prospectively monitor. The aim of this study was to assess if appointment non-adherence was correlated with medication non-adherence and a predictor of graft outcomes. This was a longitudinal cohort study that used the National United States Renal Data System and veterans affairs health records data with time-to-event analyses conducted to assess the impact on graft and patient survival. The number of transplants that were included in the analysis was 4,646 (3,656 with complete records); 14.6% of patients had an appointment no show rate of ≥12% (non-adherence). Appointment and medication non-adherence were highly correlated and both were significant independent predictors of outcomes. Those with appointment non-adherence had 1.5 times the risk of acute rejection (22.0 vs. 14.7%, p adherence; those with appointment and medication non-adherence were at very high risk of graft loss (aHR 4.18, 95% CI 3.39-5.15, p adherence (aHR 1.39, 95% CI 0.97-2.01, p = 0.0766) or only medication non-adherence (aHR 2.44, 95% CI 2.11-2.81, p adherence to health care appointments is a significant and independent risk factor for graft loss. © 2016 S. Karger AG, Basel.

  10. Medication non-adherence in the homeless population in an Intermountain West city

    Directory of Open Access Journals (Sweden)

    Elizabeth J. Unni

    2014-01-01

    Full Text Available Background: Homelessness happens when people or household are unable to acquire and/or maintain housing they can afford. Approximately 17% of homeless individuals are also chronically ill. Studies have often not objectively measured medication non- adherence among the homeless population, probably due to lack of consistent pharmacy records. This study proposed to objectively estimate medication non-adherence to chronic medications among the homeless population in Salt Lake City, Utah. Methods: A retrospective study design was used based on the pharmacy records from the Fourth Street Pharmacy based on four classes of chronic medications - asthma, diabetes, statins, and psychiatric medications. Data was collected between November 1, 2010 and February 28, 2011 on the variables: date of original prescription, number of refills on the original prescription, date of 1st, 2nd, 3rd, and 4th fills, age, gender, and race. Primary non-adherence and medication refill non-adherence based on Continuous Measure of Medication Gaps were calculated. Results: The medication refill non-adherence rate was 38.8% with asthma medications, 38.5% with diabetic medications, 27.2% with statins, and 47.1% with psychiatric medications. The primary non-adherence rate varied from zero percent to 20%. Conclusion: The study concluded that this population has comparable non-adherence rates with asthma, diabetes, cholesterol lowering, and certain psychiatric medications than the general population.   Type: Original Research

  11. Drug Non-Adherence in Type 2 Diabetes Mellitus: Predictors and Associations

    International Nuclear Information System (INIS)

    Shams, N.; Ahmed, W.; Kumar, N.; Saleem, F.

    2016-01-01

    Background: Diabetes being a serious health issue faced by developing countries with drug adherence having pivot role for recommended glycaemic target. This study aims to determine drug non-adherence in type 2 diabetics and its predictors and associations. Methods: This cross sectional study was conducted after ethical approval at Medicine Dept. Rawal Institute of Health Sciences Islamabad over 10 months duration. Demographic details, duration of diabetes, education, socioeconomic class, glycaemic control, mode of anti-diabetic therapy, number of medications and other modes of therapy documented. Michigan Diabetes Knowledge Questionnaire applied with outcome as good, acceptable and poor knowledge. Drug adherence was assessed by Morisky Medication Adherence Scale (non-adherence at <6 points). Data analysed via SPSS version 17 with significant p-value <0.05. Results: Among 183 diabetics there were 43 (23.5 percent) males and 140 (76.5 percent) females. Mean age was 56.6±10.6 years and mean duration of diabetes 8.4±6.57 years. One hundred and fourteen (62 percent) cases were non-adherent. Diabetes knowledge was poor in 76 (41.5 percent), acceptable in 76 (41.5 percent) and good in 31 (16.9 percent). Un-satisfactory glycaemic control present in 149 (81.4 percent). Non-adherence was found to be associated with poor glycaemic control, poor dietary adherence, poly-pharmacy, illiteracy, practicing other modes of therapy and poor diabetes knowledge (p<0.05). Conclusion: Non-adherence to medication in type 2 diabetics needs to be addressed. Suggested contributory factors are illiteracy, practicing other modes of therapy, poor diabetes knowledge and poly-pharmacy. Public awareness programs, self-monitoring of blood sugars, regular follow-up visits with focus at patient education may improve glycaemic control and diabetes related complications. (author)

  12. Factors relevant to medication non-adherence in kidney transplant: a systematic review.

    Science.gov (United States)

    Belaiche, Stephanie; Décaudin, Bertrand; Dharancy, Sébastien; Noel, Christian; Odou, Pascal; Hazzan, Marc

    2017-06-01

    Background Medication non-adherence is a major issue after transplant that can lead to misdiagnosis, rejection, poor health affecting quality of life, graft loss or death. Several estimations of adherence and related factors have previously been described but conclusions leave doubt as to the most accurate assessment method. Aim of the review To identify the factors most relevant to medication non-adherence in kidney transplant in current clinical practice. Method This systematic review is registered in the PROSPERO data base and follows the Prisma checklist. Articles in English in three databases from January 2009 to December 2014 were analysed. A synthesis was made to target adherence assessment methods, their prevalence and significance. Results Thirty-seven studies were analysed rates of non-adherence fluctuating from 1.6 to 96%. Assessment methods varied from one study to another, although self-reports were mainly used. It appears that youth (≤50 years old), male, low social support, unemployment, low education, ≥3 months post graft, living donor, ≥6 comorbidities, ≥5 drugs/d, ≥2 intakes/d, negative beliefs, negative behavior, depression and anxiety were the factors significantly related to non-adherence. Conclusion As there are no established guidelines, consideration should be given to more than one approach to identify medication non-adherence although self-reports should remain the cornerstone of adherence assessment.

  13. Non-adherence to diabetes treatment at Mulago Hospital in Uganda ...

    African Journals Online (AJOL)

    Background: Non-adherence to diabetes treatment leads to poor glucose control and increases the risk of disease complications. The prevalence and factors associated with non-adherence in resource limited settings should be determined so as to lower the impact of a disease that is on the increase, on the health systems ...

  14. Factors associated with non-adherence to highly active antiretroviral therapy in Nairobi, Kenya

    Directory of Open Access Journals (Sweden)

    Wakibi Samwel N

    2011-12-01

    Full Text Available Abstract Background Antiretroviral therapy (ART requires high-level (> 95% adherence. Kenya is rolling out ART access programmes and, issue of adherence to therapy is therefore imperative. However, published data on adherence to ART in Kenya is limited. This study assessed adherence to ART and identified factors responsible for non adherence in Nairobi. Methods This is a multiple facility-based cross-sectional study, where 416 patients aged over 18 years were systematically selected and interviewed using a structured questionnaire about their experience taking ART. Additional data was extracted from hospital records. Patients were grouped into adherent and non-adherent based on a composite score derived from a three questions adherence tool developed by Center for Adherence Support Evaluation (CASE. Multivariate regression model was used to determine predictors of non-adherence. Results Overall, 403 patients responded; 35% males and 65% females, 18% were non-adherent, and main (38% reason for missing therapy were being busy and forgetting. Accessing ART in a clinic within walking distance from home (OR = 2.387, CI.95 = 1.155-4.931; p = 0.019 and difficulty with dosing schedule (OR = 2.310, CI.95 = 1.211-4.408, p = 0.011 predicted non-adherence. Conclusions The study found better adherence to HAART in Nairobi compared to previous studies in Kenya. However, this can be improved further by employing fitting strategies to improve patients' ability to fit therapy in own lifestyle and cue-dose training to impact forgetfulness. Further work to determine why patients accessing therapy from ARV clinics within walking distance from their residence did not adhere is recommended.

  15. Flexible dye-sensitized solar cell fabricated on plastic substrate by laser-detachment and press method

    International Nuclear Information System (INIS)

    Kim, Choonghoe; Kim, Seongsu; Lee, Myeongkyu

    2013-01-01

    This report shows that flexible dye-sensitized solar cell can be fabricated by a laser-detachment and press method where the TiO 2 electrode typically sintered on glass source substrate is detached by a laser pulse and then is firmly adhered to the conductive plastic substrate by applying a high pressure. The cells fabricated by this process exhibited 36–43% smaller photocurrent and efficiency than the conventional glass cells with directly coated TiO 2 electrodes. It was attributed to the lowered dye coverage and electron diffusion length, both of which originate from the press-induced reduction of TiO 2 porosity. A maximum efficiency of 5.68% was obtained for the plastic cell. Bending of the electrode led to 20% loss of the current density and efficiency. However, no further performance degradation was observed even when the bending cycle was increased to 100, 300, and 500 times. This indicates that the bending-induced degradation of TiO 2 electrode on the plastic substrate takes place at the first bending.

  16. Personality and medication non-adherence among older adults enrolled in a six-year trial

    Science.gov (United States)

    Jerant, Anthony; Chapman, Benjamin; Duberstein, Paul; Robbins, John; Franks, Peter

    2011-01-01

    Objectives Personality factors parsimoniously capture the variation in dispositional characteristics that affect behaviours, but their value in predicting medication non-adherence is unclear. We investigated the relationship between five-factor model personality factors (Conscientiousness, Neuroticism, Agreeableness, Extraversion, and Openness) and medication non-adherence among older participants during a six-year randomized placebo-controlled trial (RCT). Design Observational cohort data from 771 subjects aged ≥72 years enrolled in the Ginkgo Evaluation of Memory study, a RCT of Ginkgo biloba for prevention of dementia. Methods Random effects logistic regression analyses examined effects of NEO Five-Factor Inventory scores on medication non-adherence, determined via pill counts every 6 months (median follow-up 6.1 years) and defined as taking personality factor associated with non-adherence: a 1 SD increase was associated with a 3.8% increase in the probability of non-adherence (95% CI [0.4, 7.2]). Lower cognitive function was also associated with non-adherence: a 1 SD decrease in mental status exam score was associated with a 3.0% increase in the probability of non-adherence (95% CI [0.2, 5.9]). Conclusions Neuroticism was associated with medication non-adherence over 6 years of follow-up in a large sample of older RCT participants. Personality measurement in clinical and research settings might help to identify and guide interventions for older adults at risk for medication non-adherence. PMID:21226789

  17. Integration of a Graphite/PMMA CompositeElectrode into a Poly(methyl methacrylate) (PMMA) Substrate for Electrochemical Detection in Microchips

    Science.gov (United States)

    Regel, Anne; Lunte, Susan

    2013-01-01

    Traditional fabrication methods for polymer microchips, the bonding of two substrates together to form the microchip, can make the integration of carbon electrodes difficult. We have developed a simple and inexpensive method to integrate graphite/PMMA composite electrodes (GPCEs) into a PMMA substrate. These substrates can be bonded to other PMMA layers using a solvent-assisted thermal bonding method. The optimal composition of the GPCEs for electrochemical detection was determined using cyclic voltammetry with dopamine as a test analyte. Using the optimized GPCEs in an all-PMMA flow cell with flow injection analysis, it was possible to detect 50 nM dopamine under the best conditions. These electrodes were also evaluated for the detection of dopamine and catechol following separation by microchip electrophoresis (ME). PMID:23670816

  18. Factors related to medication non-adherence for patients with hypertension in Taiwan.

    Science.gov (United States)

    Li, Wen-Wen; Kuo, Chi-Tai; Hwang, Shiow-Li; Hsu, Hsin-Tien

    2012-07-01

    To characterise a Taiwanese population and to examine the prevalence of antihypertensive medication non-adherence and how the cultural/clinical factors were associated with non-adherence in Taiwan. Antihypertensive medication non-adherence is a significant clinical issue in the United States. However, little is known about hypertension (HTN) control and cultural/clinical factors related to non-adherence in Taiwan. A convenience sample survey design was used. Data were gathered from a convenience sample of 200 subjects recruited from a large teaching hospital. Medication non-adherence and cultural/clinical factors were recorded using various self-administered questionnaires, and blood pressure was taken twice for each participant. The mean age of the participants was 60.4 (SD 11.5 years) including 62% men. Two-thirds had less than a high school education (64.5%), and the majority of them were married (86·0%) and lived with family or close friends (93.5%). The average length of HTN diagnosis was 8.6 years (SD 9.0 years). Medication non-adherence rate was 47·5%, and uncontrolled HTN rate was 49.0%. Some participants (17.0%) used Chinese herbs for treating their disease (e.g. cough) and promoting health in addition to their regular antihypertensive medications. Two factors were found to be statistically significant for predicting medication non-adherence: Lower Perceived Susceptibility to Specific Diseases [OR = 1.15 (95%CI, 1.01-1.31)] and Longer Length of HTN Diagnosis [OR = 1.06 (95%CI, 1.01-1.12)]. Taiwanese at risk of non-adherence included those who perceived lower susceptibility to specific diseases and had been diagnosed with HTN for a longer time. Those using herbs need to be studied for an impact of herbs on their adherence behaviour. These findings can help guide the development of culturally sensitive and clinically appropriate nursing interventions for HTN management in Taiwan. © 2012 Blackwell Publishing Ltd.

  19. Childhood adversity as a predictor of non-adherence to statin therapy in adulthood.

    Directory of Open Access Journals (Sweden)

    Maarit Jaana Korhonen

    Full Text Available To investigate whether adverse experiences in childhood predict non-adherence to statin therapy in adulthood.A cohort of 1378 women and 538 men who initiated statin therapy during 2008-2010 after responding to a survey on childhood adversities, was followed for non-adherence during the first treatment year. Log-binomial regression was used to estimate predictors of non-adherence, defined as the proportion of days covered by dispensed statin tablets <80%. In fully adjusted models including age, education, marital status, current smoking, heavy alcohol use, physical inactivity, obesity, presence of depression and cardiovascular comorbidity, the number of women ranged from 1172 to 1299 and that of men from 473 to 516, because of missing data on specific adversities and covariates.Two in three respondents reported at least one of the following six adversities in the family: divorce/separation of the parents, long-term financial difficulties, severe conflicts, frequent fear, severe illness, or alcohol problem of a family member. 51% of women and 44% of men were non-adherent. In men, the number of childhood adversities predicted an increased risk of non-adherence (risk ratio [RR] per adversity 1.11, 95% confidence interval [CI] 1.01-1.21], P for linear trend 0.013. Compared with those reporting no adversities, men reporting 3-6 adversities had a 1.44-fold risk of non-adherence (95% CI 1.12-1.85. Experiencing severe conflicts in the family (RR 1.27, 95% CI 1.03-1.57] and frequent fear of a family member (RR 1.27, 95% CI 1.00-1.62] in particular, predicted an increased risk of non-adherence. In women, neither the number of adversities nor any specific type of adversity predicted non-adherence.Exposure to childhood adversity may predict non-adherence to preventive cardiovascular medication in men. Usefulness of information on childhood adversities in identification of adults at high risk of non-adherence deserves further research.

  20. Non-Adherence in Patients on Peritoneal Dialysis: A Systematic Review

    OpenAIRE

    Griva, Konstadina; Lai, Alden Yuanhong; Lim, Haikel Asyraf; Yu, Zhenli; Foo, Marjorie Wai Yin; Newman, Stanton P.

    2014-01-01

    Background: It has been increasingly recognized that non-adherence is an important factor that determines the outcome of peritoneal dialysis (PD) therapy. There is therefore a need to establish the levels of non-adherence to different aspects of the PD regimen (dialysis procedures, medications, and dietary/fluid restrictions). Methods: A systematic review of peer-reviewed literature was performed in PubMed, PsycINFO and CINAHL databases using PRISMA guidelines in May 2013. Publications on non...

  1. A risk stratification model for antihypertensive medication non-adherence among Chinese immigrants

    Directory of Open Access Journals (Sweden)

    Wen-Wen Li

    2016-12-01

    Full Text Available The purpose of this study was to establish a risk stratification model for identifying Chinese immigrants at risk for non-adherence to antihypertensive medications. Questionnaires were self-administered to 200 Chinese immigrants in San Francisco, USA. Questionnaires included demographics, culture factors (e.g., Perceived Susceptibility in General, Perceived Benefits of Western Medication, Perceived Benefits of Chinese Herbs, and Health-Related Social Support, and medications adherence. Participants' mean age was 70.6 (±10.3 years. Three stratification factors were identified for non-adherence: Lower Perceived Susceptibility in General, lower Perceived Benefit of Western Medications, and longer Length of Stay in the United States. The probability of non-adherence was 77%, 62%, and 57% for lower perceived susceptibility, longer stay in the United States, and lower perceived benefits of Western medications, respectively. A combination of lower perceived susceptibility and lower perceived benefits of medication predicted 81% non-adherence and lower perceived susceptibility with longer stay in the United States predicted at 84%. All three factors combined predicted nearly 90%. Patients with all three factors had the highest risk for non-adherence. The second priority groups are patients with lower perceived susceptibility and those with lower perceived susceptibility combined with any of the other two factors. In the clinical setting, these three groups are a high priority for education on the importance of medication adherence.

  2. Design and development of plasmonic nanostructured electrodes for ITO-free organic photovoltaic cells on rigid and highly flexible substrates

    Science.gov (United States)

    Richardson, Beau J.; Zhu, Leize; Yu, Qiuming

    2017-04-01

    Indium tin oxide (ITO) is the most common transparent electrode used in organic photovoltaics (OPVs), yet limited indium reserves and poor mechanical properties make it non-ideal for large-scale OPV production. To replace ITO, we designed, fabricated, and deployed plasmonic nanostructured electrodes in inverted OPV devices. We found that active layer absorption is significantly impacted by ZnO thickness which affects the optical field distribution inside the resonant cavity formed between the plasmonic nanostructured electrode and top electrode. High quality Cr/Au nanostructured electrodes were fabricated by nanoimprint lithography and deployed in ITO-free inverted devices on glass. Devices with thinner ZnO showed a PCE as high as 5.70% and higher J SC’s than devices on thicker ZnO, in agreement with finite-difference time-domain simulations. In addition, as the active layer was made optically thin, ITO-based devices showed diminished J SC while the resonant cavity effect from plasmonic nanostructured electrodes retained J SC. Preliminary ITO-free, flexible devices on PET showed a PCE of 1.82% and those fabricated on ultrathin and conformable Parylene substrates yielded an initial PCE over 1%. The plasmonic electrodes and device designs in this work show promise for developing highly functioning conformable devices that can be applied to numerous needs for lightweight, ubiquitous power generation.

  3. Non-adherence to antipsychotic medication, relapse and rehospitalisation in recent-onset schizophrenia

    Directory of Open Access Journals (Sweden)

    Widen Jan H

    2008-04-01

    Full Text Available Abstract Background The aims of this study were to describe outcome with respect to persistent psychotic symptoms, relapse of positive symptoms, hospital admissions, and application of treatment by coercion among patients with recent onset schizophrenia being adherent and non-adherent to anti-psychotic medication. Materials and methods The study included 50 patients with recent onset schizophrenia, schizoaffective or schizophreniform disorders. The patients were clinically stable at study entry and had less than 2 years duration of psychotic symptoms. Good adherence to antipsychotic medication was defined as less than one month without medication. Outcomes for poor and good adherence were compared over a 24-month follow-up period. Results The Odds Ratio (OR of having a psychotic relapse was 10.27 and the OR of being admitted to hospital was 4.00 among non-adherent patients. Use of depot-antipsychotics were associated with relapses (OR = 6.44. Conclusion Non-adherence was associated with relapse, hospital admission and having persistent psychotic symptoms. Interventions to increase adherence are needed. Trial registration Current Controlled Trials NCT00184509. Key words: Adherence, schizophrenia, antipsychotic medication, admittances, relapse.

  4. Development of 3D carbon nanotube interdigitated finger electrodes on polymer substrate for flexible capacitive sensor application

    International Nuclear Information System (INIS)

    Hu, Chih-Fan; Wang, Jhih-Yu; Fang, Weileun; Liu, Yu-Chia; Tsai, Ming-Han

    2013-01-01

    This study reports a novel approach to the implementation of 3D carbon nanotube (CNT) interdigitated finger electrodes on flexible polymer, and the detection of strain, bending curvature, tactile force and proximity distance are demonstrated. The merits of the presented CNT-based flexible sensor are as follows: (1) the silicon substrate is patterned to enable the formation of 3D vertically aligned CNTs on the substrate surface; (2) polymer molding on the silicon substrate with 3D CNTs is further employed to transfer the 3D CNTs to the flexible polymer substrate; (3) the CNT–polymer composite (∼70 μm in height) is employed to form interdigitated finger electrodes to increase the sensing area and initial capacitance; (4) other structures such as electrical routings, resistors and mechanical supporters are also available using the CNT–polymer composite. The preliminary fabrication results demonstrate a flexible capacitive sensor with 50 μm high CNT interdigitated electrodes on a poly-dimethylsiloxane substrate. The tests show that the typical capacitance change is several dozens of fF and the gauge factor is in the range of 3.44–4.88 for strain and bending curvature measurement; the sensitivity of the tactile sensor is 1.11% N −1 ; a proximity distance near 2 mm away from the sensor can be detected. (paper)

  5. Antipsychotic medication non-adherence among schizophrenia ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Non-adherence can cause high rates of relapse within 5 years of recovery from the first episode.7. Thus, lack of .... schizophrenia patients at Amanuel Mental Specialized Hospital, Addis Ababa,. Ethiopia, June 2014 (n = 412). 0. No substance use. Alcohol. Cigarre e. Chat. Alcohol/Cigarete/Chat. Cigarrete/ ...

  6. Patterning of metallic electrodes on flexible substrates for organic thin-film transistors using a laser thermal printing method

    International Nuclear Information System (INIS)

    Chen, Kun-Tso; Lin, Yu-Hsuan; Ho, Jeng-Rong; Chen, Chih-Kant; Liu, Sung-Ho; Liao, Jin-Long; Cheng, Hua-Chi

    2011-01-01

    We report on a laser thermal printing method for transferring patterned metallic thin films on flexible plastic substrates using a pulsed CO 2 laser. Aluminium and silver line patterns, with micrometre scale resolution on poly(ethylene terephthalate) substrates, are shown. The printed electrodes demonstrate good conductivity and fulfil the properties for bottom-contact organic thin-film transistors. In addition to providing the energy for transferring the film, the absorption of laser light results in a rise in the temperature of the film and the substrate. This also further anneals the film and softens the plastic substrate. Consequently, it is possible to obtain a film with better surface morphology and with its film thickness implanted in part into the plastic surface. This implantation reveals excellent characteristics in adhesion and flexure resistance. Being feasible to various substrates and executable at ambient temperatures renders this approach a potential alternative for patterning metallic electrodes.

  7. Highly flexible indium zinc oxide electrode grown on PET substrate by cost efficient roll-to-roll sputtering process

    International Nuclear Information System (INIS)

    Park, Yong-Seok; Kim, Han-Ki; Jeong, Soon-Wook; Cho, Woon-Jo

    2010-01-01

    We have investigated the characteristics of flexible indium zinc oxide (IZO) electrode grown on polyethylene terephthalate (PET) substrates using a specially designed roll-to-roll (RTR) sputtering system for use in flexible optoelectronics. It was found that both electrical and optical properties of the flexible IZO electrode were critically dependent on the DC power and Ar/O 2 flow ratio during the roll-to-roll sputtering process. At optimized conditions (constant working pressure of 3 mTorr, Ar/O 2 flow ratio of Ar at only 30 sccm, DC power 800 W and rolling speed at 0.1 cm/s) the flexible IZO electrode exhibits a sheet resistance of 17.25 Ω/sq and an optical transmittance of 89.45% at 550 nm wavelength. Due to the low PET substrate temperature, which is effectively maintained by cooling drum system, all IZO electrodes showed an amorphous structure regardless of the DC power and Ar/O 2 flow ratio. Furthermore, the IZO electrodes grown at optimized condition exhibited superior flexibility than the conventional amorphous ITO electrodes due to its stable amorphous structure. This indicates that the RTR sputter grown IZO electrode is a promising flexible electrode that can substitute for the conventional ITO electrode, due to its low resistance, high transparency, superior flexibility and fast preparation by the RTR process.

  8. Predictors of Non-Adherence to Breast Cancer Screening among Hospitalized Women.

    Directory of Open Access Journals (Sweden)

    Waseem Khaliq

    Full Text Available Disparities in screening mammography use persists among low income women, even those who are insured, despite the proven mortality benefit. A recent study reported that more than a third of hospitalized women were non-adherent with breast cancer screening. The current study explores prevalence of socio-demographic and clinical variables associated with non-adherence to screening mammography recommendations among hospitalized women.A cross sectional bedside survey was conducted to collect socio-demographic and clinical comorbidity data thought to effect breast cancer screening adherence of hospitalized women aged 50-75 years. Logistic regression models were used to assess the association between these factors and non-adherence to screening mammography.Of 250 enrolled women, 61% were of low income, and 42% reported non-adherence to screening guidelines. After adjustment for socio-demographic and clinical predictors, three variables were found to be independently associated with non-adherence to breast cancer screening: low income (OR = 3.81, 95%CI; 1.84-7.89, current or ex-smoker (OR = 2.29, 95%CI; 1.12-4.67, and history of stroke (OR = 2.83, 95%CI; 1.21-6.60. By contrast, hospitalized women with diabetes were more likely to be compliant with breast cancer screening (OR = 2.70, 95%CI 1.35-5.34.Because hospitalization creates the scenario wherein patients are in close proximity to healthcare resources, at a time when they may be reflecting upon their health status, strategies could be employed to counsel, educate, and motivate these patients towards health maintenance. Capitalizing on this opportunity would involve offering screening during hospitalization for those who are overdue, particularly for those who are at higher risk of disease.

  9. Experiences of non-adherence to Internet-delivered cognitive behavior therapy: A qualitative study

    OpenAIRE

    Johansson, Olof; Michel, Teresa; Andersson, Gerhard; Paxling, Björn

    2015-01-01

    Many trials on Internet-delivered psychological treatments have had problems with nonadherence, but not much is known about the subjective reasons for non-adhering. The aim of this study was to explore participants' experiences of non-adherence to Internet-delivered psychological treatment. Grounded theory was used to analyze data from seven in-depth interviews with persons who had non-adhered to a study on Internet-delivered cognitive behavioral therapy for generalized anxiety disorder. The ...

  10. Non-adherence to telemedicine interventions for drug users: systematic review

    Directory of Open Access Journals (Sweden)

    Taís de Campos Moreira

    2014-06-01

    Full Text Available OBJECTIVE To estimate rates of non-adherence to telemedicine strategies aimed at treating drug addiction. METHODS A systematic review was conducted of randomized controlled trials investigating different telemedicine treatment methods for drug addiction. The following databases were consulted between May 18, 2012 and June 21, 2012: PubMed, PsycINFO, SciELO, Wiley (The Cochrane Library, Embase, Clinical trials and Google Scholar. The Grading of Recommendations Assessment, Development and Evaluation was used to evaluate the quality of the studies. The criteria evaluated were: appropriate sequence of data generation, allocation concealment, blinding, description of losses and exclusions and analysis by intention to treat. There were 274 studies selected, of which 20 were analyzed. RESULTS Non-adherence rates varied between 15.0% and 70.0%. The interventions evaluated were of at least three months duration and, although they all used telemedicine as support, treatment methods differed. Regarding the quality of the studies, the values also varied from very poor to high quality. High quality studies showed better adherence rates, as did those using more than one technique of intervention and a limited treatment time. Mono-user studies showed better adherence rates than poly-user studies. CONCLUSIONS Rates of non-adherence to treatment involving telemedicine on the part of users of psycho-active substances differed considerably, depending on the country, the intervention method, follow-up time and substances used. Using more than one technique of intervention, short duration of treatment and the type of substance used by patients appear to facilitate adherence.

  11. Risk factors for antipsychotic medication non-adherence behaviors and attitudes in adult-onset psychosis.

    Science.gov (United States)

    Hui, Christy Lai Ming; Poon, Venessa Wing Yan; Ko, Wai Tung; Miao, Ho Yee; Chang, Wing Chung; Lee, Edwin Ho Ming; Chan, Sherry Kit Wa; Lin, Jingxia; Chen, Eric Yu Hai

    2016-07-01

    Research on antipsychotic medication non-adherence in first-episode psychosis patients tends to examine non-adherence behaviors and attitudes together. Nonetheless, attitudes do not always directly translate into behaviors. We examined the baseline predictors for antipsychotics non-adherence behaviors and attitudes separately in a first-episode psychosis cohort. We also included cognitive impairments as one of the predictor variables as this domain is rarely explored in adherence studies. Participants were 313 adult-onset psychosis patients recruited from the Jockey Club Early Psychosis project in Hong Kong. Demographic, premorbid, clinical, and cognitive characteristics were first assessed at baseline. Six months later, participants completed a 14-item Medication Compliance Questionnaire, which was a modified and Cantonese-translated version of the Medication Adherence Rating Scale that includes items pertaining to both adherence behaviors and attitudes. Rates of poor adherence behaviors and negative adherence attitudes were 17.6% and 27.8%, respectively. Determinants of poor adherence behavior included more severe positive symptoms, hospitalization at onset of illness, and poorer engagement in extended social network. As for negative adherence attitude, determinants included more severe general psychopathology, poorer insight, more psychic medication side-effects, and poorer performance on backward digit span test and WAIS-R information test. The risk factors for non-adherence behaviors and attitudes are different and they should all be taken into careful consideration while formulating appropriate intervention programs to tackle the adherence problem in adult onset psychosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Pinpointing differences in cisplatin-induced apoptosis in adherent and non-adherent cancer cells

    DEFF Research Database (Denmark)

    Tastesen, Hanne Sørup; Holm, Jacob Bak; Poulsen, Kristian Arild

    2010-01-01

    Platinum compounds are used in the treatment of cancer. We demonstrate that cisplatin-induced (10 µM) apoptosis (caspase-3 activity) is pronounced within 18 hours in non-adherent Ehrlich ascites tumour cells (EATC), whereas there is no increase in caspase-3 activity in the adherent Ehrlich Lettré...... ascites tumour cells (ELA). Loss of KCl and cell shrinkage are hallmarks in apoptosis and has been shown in EATC. However, we find no reduction in cell volume and only a minor loss of K(+) which is accompanied by net uptake of Na(+) following 18 hours cisplatin exposure in ELA. Glutathione and taurine...

  13. Non-adherence to standard treatment guidelines in a rural paediatric hospital in Sierra Leone.

    Science.gov (United States)

    De Bruycker, M; Van den Bergh, R; Dahmane, A; Khogali, M; Schiavetti, B; Nzomukunda, Y; Alders, P; Allaouna, M; Cloquet, C; Enarson, D A; Satyarayanan, S; Magbity, E; Zachariah, R

    2013-06-21

    A rural paediatric hospital in Bo, Sierra Leone. To assess the level of adherence to standard treatment guidelines among clinicians prescribing treatment for children admitted with a diagnosis of malaria and/or lower respiratory tract infection (LRTI), and determine the association between (non) adherence and hospital outcomes, given that non-rational use of medicines is a serious global problem. Secondary analysis of routine programme data. Data were collected for 865 children admitted with an entry diagnosis of malaria and 690 children with LRTI during the period January to April 2011; some patients were classified in both categories. Non-adherence to guidelines comprised use of non-standard drug regimens, dosage variations, non-standard frequency of administration and treatment duration. Cumulative non-adherence to guidelines for LRTI cases was 86%. For malaria, this involved 12% of patients. Potentially harmful non-adherence was significantly associated with an unfavourable hospital outcome, both for malaria and for LRTI cases. Overall non-adherence to standard treatment guidelines by clinicians in a routine hospital setting is very high and influences hospital outcomes. This study advocates for the implementation of routine measures to monitor and improve rational drug use and the quality of clinical care in such hospitals.

  14. Patient-reported non-adherence and immunosuppressant trough levels are associated with rejection after renal transplantation.

    Science.gov (United States)

    Scheel, Jennifer; Reber, Sandra; Stoessel, Lisa; Waldmann, Elisabeth; Jank, Sabine; Eckardt, Kai-Uwe; Grundmann, Franziska; Vitinius, Frank; de Zwaan, Martina; Bertram, Anna; Erim, Yesim

    2017-03-29

    Different measures of non-adherence to immunosuppressant (IS) medication have been found to be associated with rejection episodes after successful transplantation. The aim of the current study was to investigate whether graft rejection after renal transplantation is associated with patient-reported IS medication non-adherence and IS trough level variables (IS trough level variability and percentage of sub-therapeutic IS trough levels). Patient-reported non-adherence, IS trough level variability, percentage of sub-therapeutic IS trough levels, and acute biopsy-proven late allograft rejections were assessed in 267 adult renal transplant recipients who were ≥12 months post-transplantation. The rate of rejection was 13.5%. IS trough level variability, percentage of sub-therapeutic IS trough levels as well as patient-reported non-adherence were all significantly and positively associated with rejection, but not with each other. Logistic regression analyses revealed that only the percentage of sub-therapeutic IS trough levels and age at transplantation remained significantly associated with rejection. Particularly, the percentage of sub-therapeutic IS trough levels is associated with acute rejections after kidney transplantation whereas IS trough level variability and patient-reported non-adherence seem to be of subordinate importance. Patient-reported non-adherence and IS trough level variables were not correlated; thus, non-adherence should always be measured in a multi-methodological approach. Further research concerning the best combination of non-adherence measures is needed.

  15. Orientation- and position-controlled alignment of asymmetric silicon microrod on a substrate with asymmetric electrodes

    Science.gov (United States)

    Shibata, Akihide; Watanabe, Keiji; Sato, Takuya; Kotaki, Hiroshi; Schuele, Paul J.; Crowder, Mark A.; Zhan, Changqing; Hartzell, John W.; Nakatani, Ryoichi

    2014-03-01

    In this paper, we demonstrate the orientation-controlled alignment of asymmetric Si microrods on a glass substrate with an asymmetric pair of electrodes. The Si microrods have the shape of a paddle with a blade and a shaft part, and the pair of electrodes consists of a narrow electrode and a wide electrode. By applying AC bias to the electrodes, the Si microrods suspended in a fluid align in such a way to settle across the electrode pair, and over 80% of the aligned Si microrods have an orientation with the blade and the shaft of the paddle on the wide and the narrow electrodes, respectively. When Si microrods have a shell of dielectric film and its thickness on the top face is thicker than that on the bottom face, 97.8% of the Si microrods are aligned with the top face facing upwards. This technique is useful for orientation-controlled alignment of nano- and microsized devices that have polarity or a distinction between the top and bottom faces.

  16. Non-adherence to life-style modification and its factors among type 2 diabetic patients.

    Science.gov (United States)

    Mumu, Shirin Jahan; Saleh, Farzana; Ara, Ferdous; Afnan, Fadia; Ali, Liaquat

    2014-01-01

    Non-adherence to preventive and therapeutic life-style recommendations among patients with diabetes is special challenge in the management of these patients. This study aimed to measure the proportion of non-adherence to life-style modification and factors associated with these among a group of Bangladeshi type 2 diabetic patients. Under an analytical cross-sectional design 374 type 2 diabetic patients (age >20 years), diagnosed for at least 1 year, were selected from different health care centers operated by the Diabetic Association of Bangladesh. Non-adherence rate were assessed for: Diet (88%), exercise (25%), routine blood glucose testing (32%), foot care (70%), smoking (6%) and betel quid chewing habit (25%). Binary logistic regression suggests that higher education group (P = 0.013), rural area (P = 0.013) and attendance to diabetes education classes (P = 0.043) showed good adherence to diet and non-attendance to diabetes education class (P = 0.014), older age (P = 0.037) are associated to non-adherence to exercise. Unemployed patients showed more non-adherence to blood glucose testing (P = 0.045) than others. Non-attendance to diabetes education class (P = 0.037) and business occupation group (P = 0.039) showed significant association to smoking and betel quid intake habit respectively.

  17. Socioeconomic disadvantage and primary non-adherence with medication in Sweden.

    Science.gov (United States)

    Wamala, Sarah; Merlo, Juan; Bostrom, Gunnel; Hogstedt, Christer; Agren, Gunner

    2007-06-01

    Lack of adherence with pharmacological therapy is a public health concern that compels tremendous costs for the health care system and the community. To analyse the association between socioeconomic disadvantage and primary non-adherence with medication, and to explore possible mediating effects of trust in health care and lifestyle profile. Cross-sectional population-based study based on data from the Swedish national public health surveys 2004-2005. The study comprised 13603 men and 18292 women aged 21-84 years who had any contact with a physician at a hospital or primary care centre. Measures Primary non-adherence with medication based on whether respondents reported that they refrained from purchasing at the pharmacy prescribed medication. Socioeconomic Disadvantage Index was based on four different indicators of economic deprivation. Socioeconomic disadvantage was associated with primary non-adherence with medication independent of long-term illness, risky lifestyle, low education, living alone and low trust for health care. This association increased with older age, particularly among women. Among individuals aged 21-34 years, severe compared with no socioeconomic disadvantage, was associated with two-fold increased odds for non-adherence with medication. The corresponding odds among individuals aged 65-84 years were three-fold increase among elderly men (OR=3.3, 95% CI: 1.4-7.8) and six-fold increase among elderly women (OR=6.2, 95% CI: 2.5-15.3). Yet every seventh elderly woman aged 65-84 years suffered from long-term illness. Results indicate that health policies for 'care on equal terms' in Sweden have been less successful in relation to equitable access to prescribed medication, especially among the elderly.

  18. Prevalence and Modifiable Determinants of Non-Adherence in Adult Kidney Transplant Recipients in a German Sample.

    Science.gov (United States)

    Reber, Sandra; Morawa, Eva; Stößel, Lisa; Jank, Sabine; Vitinius, Frank; Eckardt, Kai-Uwe; Erim, Yesim

    2016-09-01

    The aim of this cross-sectional study was to investigate the prevalence and the modifiable determinants of non-adherence in adult kidney transplant patients in follow-up care. In 74 patients at least six months post-transplant, self-reported adherence (Basel Assessment of Adherence to ImmunosuppressiveMedications Scale, BAASIS©), subjective experience and attitudes after transplantation (Medication Experience Scale for Immunosuppressants, MESI), and depression and anxiety (Hospital Anxiety and Depression Scale,HADSD) were assessed. Non-adherence to any of the four BAASIS© items was 24.3%. For the sub-dimensions: dose taking, drug holidays, timing deviation more than two hours from prescribed time, and dose reduction, the non-adherence levelswere 9.5%, 0%,17.6% and 2.7%, respectively. Marital status, negative beliefs towards immunosuppressants, and prominent anxiety and depression were associated with non-adherence. Screening for adherence and its indicators is of substantial importance in communication with renal transplant recipients. After detecting non-adherence, supportive interventions can be offered to the patients.

  19. Flexible Pressure Sensor with Ag Wrinkled Electrodes Based on PDMS Substrate

    Directory of Open Access Journals (Sweden)

    Jianli Cui

    2016-12-01

    Full Text Available Flexible pressure sensors are essential components of electronic skins for future attractive applications ranging from human healthcare monitoring to biomedical diagnostics, robotic skins, and prosthetic limbs. Here we report a new kind of flexible pressure sensor. The sensors are capacitive, and composed of two Ag wrinkled electrodes separated by a carbon nanotubes (CNTs/polydimethylsiloxane (PDMS composite deformable dielectric layer. Ag wrinkled electrodes were formed by vacuum deposition on top of pre-strained and relaxed PDMS substrates which were treated using an O2 plasma, a surface functionalization process, and a magnetron sputtering process. Ultimately, the developed sensor exhibits a maximum sensitivity of 19.80% kPa−1 to capacitance, great durability over 500 cycles, and rapid mechanical responses (<200 ms. We also demonstrate that our sensor can be used to effectively detect the location and distribution of finger pressure.

  20. Non-adherence to immunosuppressive medications in kidney transplantation: intent vs. forgetfulness and clinical markers of medication intake.

    Science.gov (United States)

    Griva, Konstadina; Davenport, Andrew; Harrison, Michael; Newman, Stanton P

    2012-08-01

    Although adherence to immunosupressive medication after transplantation is important to maximize good clinical outcomes it remains suboptimal and not well-understood. The purpose of this study was to examine intentional and unintentional non-adherence to immunosuppression medication in kidney transplant patients. A cross-sectional sample of N=218 patients [49.6 ± 12.3 years] recruited in London, UK (1999-2002) completed measures of medication beliefs, quality-of-life, depression, and transplantation-specific emotions. Adherence was measured with self-report and serial immunosuppressive assays. Intentional non-adherence was low (13.8 %) yet 62.4 % admitted unintentional non-adherence and 25.4 % had sub-target immunosuppressive levels. The risk of sub-target serum immunosuppressive levels was greater for patients admitting unintentional non-adherence (OR=8.4; p=0.004). Dialysis vintage, doubts about necessity, and lower worry about viability of graft explained R(2)=16.1 to 36 % of self-report non-adherence. Depression was related only to intentional non-adherence. Non-adherence is common in kidney transplantation. Efforts to increase adherence should be implemented by targeting necessity beliefs, monitoring depression, and promoting strategies to decrease forgetfulness.

  1. Adherent diamond film deposited on Cu substrate by carbon transport from nanodiamond buried under Pt interlayer

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xuezhang [School of Materials Science and Engineering, Central South University, Changsha, 410083 (China); Wei Qiuping, E-mail: qiupwei@csu.edu.cn [School of Materials Science and Engineering, Central South University, Changsha, 410083 (China); State Key Laboratory of Powder Metallurgy, Central South University, Changsha, 410083 (China); Yu Zhiming, E-mail: zhiming@csu.edu.cn [School of Materials Science and Engineering, Central South University, Changsha, 410083 (China); State Key Laboratory of Powder Metallurgy, Central South University, Changsha, 410083 (China); Yang Taiming; Zhai Hao [School of Materials Science and Engineering, Central South University, Changsha, 410083 (China)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Adherent polycrystalline diamond films were grown on copper substrate by carbon transport. Black-Right-Pointing-Pointer The nucleation density was increased to 10{sup 11} cm{sup -2}. Black-Right-Pointing-Pointer Diamond films were a composite structure of nano-crystalline diamond layer and micro-crystalline diamond layer. Black-Right-Pointing-Pointer Diamond nucleation was based by carbon dissolving from UDDs to Pt interlayer and formation of sp{sup 3}-bonded diamond clusters at the Pt surface. - Abstract: Diamond film deposited on Cu suffered from poor adhesion mainly due to the large mismatch of thermal expansion coefficients and the lack of affinity between carbon and Cu. Enhancing diamond nucleation by carbon transport from buried nanodiamond through a Pt ultrathin interlayer, adherent diamond film was then deposited on Cu substrate without distinctly metallic interlayer. This novel nucleation mechanism increased diamond nucleation density to 10{sup 11} cm{sup -2}, and developed diamond film with a composite structure of nano-crystalline diamond (NCD) layer and micro-crystalline diamond layer. Diamond film was characterized by the scanning electron microscope (SEM) and Raman spectroscope, respectively. The composition of diamond film/Cu substrate interface was examined by electron probe microanalysis (EPMA). The adhesion of diamond film was evaluated by indentation test. Those results show that a Pt ultrathin interlayer provides stronger chemically bonded interfaces and improve film adhesion.

  2. Adherent diamond film deposited on Cu substrate by carbon transport from nanodiamond buried under Pt interlayer

    International Nuclear Information System (INIS)

    Liu Xuezhang; Wei Qiuping; Yu Zhiming; Yang Taiming; Zhai Hao

    2013-01-01

    Highlights: ► Adherent polycrystalline diamond films were grown on copper substrate by carbon transport. ► The nucleation density was increased to 10 11 cm −2 . ► Diamond films were a composite structure of nano-crystalline diamond layer and micro-crystalline diamond layer. ► Diamond nucleation was based by carbon dissolving from UDDs to Pt interlayer and formation of sp 3 -bonded diamond clusters at the Pt surface. - Abstract: Diamond film deposited on Cu suffered from poor adhesion mainly due to the large mismatch of thermal expansion coefficients and the lack of affinity between carbon and Cu. Enhancing diamond nucleation by carbon transport from buried nanodiamond through a Pt ultrathin interlayer, adherent diamond film was then deposited on Cu substrate without distinctly metallic interlayer. This novel nucleation mechanism increased diamond nucleation density to 10 11 cm −2 , and developed diamond film with a composite structure of nano-crystalline diamond (NCD) layer and micro-crystalline diamond layer. Diamond film was characterized by the scanning electron microscope (SEM) and Raman spectroscope, respectively. The composition of diamond film/Cu substrate interface was examined by electron probe microanalysis (EPMA). The adhesion of diamond film was evaluated by indentation test. Those results show that a Pt ultrathin interlayer provides stronger chemically bonded interfaces and improve film adhesion.

  3. Cobalt phthalocyanine modified electrodes utilised in electroanalysis: nano-structured modified electrodes vs. bulk modified screen-printed electrodes.

    Science.gov (United States)

    Foster, Christopher W; Pillay, Jeseelan; Metters, Jonathan P; Banks, Craig E

    2014-11-19

    Cobalt phthalocyanine (CoPC) compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC) onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes L-ascorbic acid, oxygen and hydrazine. It is found that no "electrocatalysis" is observed towards L-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where "electrocatalysis" has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate.

  4. Bypassing non-adherence via PEG in a critically ill HIV-1-infected patient.

    Science.gov (United States)

    Leipe, J; Hueber, A J; Rech, J; Harrer, T

    2008-08-01

    This case study describes a 44-year-old, chronically non-adherent, HIV-infected male with relapsing, life threatening toxoplasmic encephalitis (TE) and other recurring opportunistic infections. Non-adherence resulted in critical illness, suppressed CD4 lymphocyte count and elevated viral load. In order to bypass the patient's complete psychological aversion to taking medication, and after exhausting various psychological interventions, a percutaneous endoscopic gastronomy (PEG) tube was inserted for delivery of indispensable medication. During the 15-month follow-up the patient was adherent, exhibiting a consistently undetectable viral load, high CD4 count and a remission of the opportunistic infections. This is an interesting case study demonstrating life-saving and long-term benefit of PEG in an exceptional setting, which has implications for future research and treatment of non-adherent HIV-infected patients.

  5. Behavioral measures to reduce non-adherence in renal transplant recipients: a prospective randomized controlled trial.

    Science.gov (United States)

    Garcia, Márcia Fátima Faraldo Martinez; Bravin, Ariane Moyses; Garcia, Paula Dalsoglio; Contti, Mariana Moraes; Nga, Hong Si; Takase, Henrique Mochida; de Andrade, Luis Gustavo Modelli

    2015-11-01

    Solid-organ transplant recipients present a high rate of non-adherence to drug treatment. Few interventional studies have included approaches aimed at increasing adherence. The objective of this study was to evaluate the impact of an educational and behavioral strategy on treatment adherence of kidney transplant recipients. In a randomized prospective study, incident renal transplant patients (n = 111) were divided into two groups: control group (received usual transplant patient education) and treatment group (usual transplant patient education plus ten additional weekly 30-min education/counseling sessions about immunosuppressive drugs and behavioral changes). Treatment adherence was assessed using ITAS adherence questionnaire after 3 months. Renal function at 3, 6, and 12 months, and the incidence of transplant rejection were evaluated. The non-adherence rates were 46.4 and 14.5 % in the control and treatment groups (p = 0.001), respectively. The relative risk for non-adherence was 2.59 times (CI 1.38-4.88) higher in the control group. Multivariate analysis demonstrated a 5.84 times (CI 1.8-18.8, p = 0.003) higher risk of non-adherence in the control group. There were no differences in renal function and rejection rates between groups. A behavioral and educational strategy addressing the patient's perceptions and knowledge about the anti-rejection drugs significantly improved the short-term adherence to immunosuppressive therapy.

  6. Psychosocial and demographic predictors of adherence and non-adherence to health advice accompanying air quality warning systems: a systematic review.

    Science.gov (United States)

    D'Antoni, Donatella; Smith, Louise; Auyeung, Vivian; Weinman, John

    2017-09-22

    Although evidence shows that poor air quality can harm human health, we have a limited understanding about the behavioural impact of air quality forecasts. Our aim was to understand to what extent air quality warning systems influence protective behaviours in the general public, and to identify the demographic and psychosocial factors associated with adherence and non-adherence to the health advice accompanying these warnings. In August 2016 literature was systematically reviewed to find studies assessing intended or actual adherence to health advice accompanying air quality warning systems, and encouraging people to reduce exposure to air pollution. Predictors of adherence to the health advice and/or self-reported reasons for adherence or non-adherence were also systematically reviewed. Studies were included only if they involved participants who were using or were aware of these warning systems. Studies investigating only protective behaviours due to subjective perception of bad air quality alone were excluded. The results were narratively synthesised and discussed within the COM-B theoretical framework. Twenty-one studies were included in the review: seventeen investigated actual adherence; three investigated intended adherence; one assessed both. Actual adherence to the advice to reduce or reschedule outdoor activities during poor air quality episodes ranged from 9.7% to 57% (Median = 31%), whereas adherence to a wider range of protective behaviours (e.g. avoiding busy roads, taking preventative medication) ranged from 17.7% to 98.1% (Median = 46%). Demographic factors did not consistently predict adherence. However, several psychosocial facilitators of adherence were identified. These include knowledge on where to check air quality indices, beliefs that one's symptoms were due to air pollution, perceived severity of air pollution, and receiving advice from health care professionals. Barriers to adherence included: lack of understanding of the indices

  7. Cobalt Phthalocyanine Modified Electrodes Utilised in Electroanalysis: Nano-Structured Modified Electrodes vs. Bulk Modified Screen-Printed Electrodes

    Directory of Open Access Journals (Sweden)

    Christopher W. Foster

    2014-11-01

    Full Text Available Cobalt phthalocyanine (CoPC compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes L-ascorbic acid, oxygen and hydrazine. It is found that no “electrocatalysis” is observed towards L-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where “electrocatalysis” has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate.

  8. Understanding Statin Non-Adherence: Knowing Which Perceptions and Experiences Matter to Different Patients.

    Directory of Open Access Journals (Sweden)

    Hans Wouters

    Full Text Available Non-adherence to statins is substantial and is associated with numerous perceptions and experiences. However, time limits in clinical practice constrain in depth explorations of these perceptions and experiences.To propose and examine a strategy aimed at an efficient assessment of a wide array of perceptions and experiences regarding the efficacy, side effects, and practical problems of statins. Furthermore, to assess associations between this wide array of experiences and perceptions and non-adherence and to examine whether patients' 'perceived self-efficacy' moderated these associations.Patients were recruited through community pharmacies. A wide array of specific patient perceptions and experiences was efficiently assessed using the electronic Tailored Medicine Inventory that allows people to skip irrelevant questions. Adherence was measured through self-report and pharmacy refill data.Of the two-hundred twenty-nine patients who participated (mean age 63.9, standard deviation 10.2, 40%-70% doubted the necessity of or lacked knowledge about the efficacy of statins, 20%-35% of the patients were worried about joint and muscle side effects or had experienced these, and 23% had encountered practical problems regarding information about statins, intake of tablets, the package, or the blister. Experiencing more practical problems was associated with increased unintentional non-adherence (Odds ratio 1.54, 95%CI:1.13-2.10, P < 0.01, whereas worrying about side effects was associated with increased intentional non-adherence (Odds ratio 1.90, 95%CI:1.17-3.08, P < 0.01. Higher 'perceived self-efficacy' did not moderate these associations.Insight into patients' specific barriers with regard to appropriate statin use may reveal personal reasons for being non-adherent. The Tailored Medicine Inventory is a promising tool to devise individualized intervention strategies aimed at improving adherence by the clinician-patient alliance.

  9. Cellular volume regulation and substrate stiffness modulate the detachment dynamics of adherent cells

    Science.gov (United States)

    Yang, Yuehua; Jiang, Hongyuan

    2018-03-01

    Quantitative characterizations of cell detachment are vital for understanding the fundamental mechanisms of cell adhesion. Experiments have found that cell detachment shows strong rate dependence, which is mostly attributed to the binding-unbinding kinetics of receptor-ligand bond. However, our recent study showed that the cellular volume regulation can significantly regulate the dynamics of adherent cell and cell detachment. How this cellular volume regulation contributes to the rate dependence of cell detachment remains elusive. Here, we systematically study the role of cellular volume regulation in the rate dependence of cell detachment by investigating the cell detachments of nonspecific adhesion and specific adhesion. We find that the cellular volume regulation and the bond kinetics dominate the rate dependence of cell detachment at different time scales. We further test the validity of the traditional Johnson-Kendall-Roberts (JKR) contact model and the detachment model developed by Wyart and Gennes et al (W-G model). When the cell volume is changeable, the JKR model is not appropriate for both the detachments of convex cells and concave cells. The W-G model is valid for the detachment of convex cells but is no longer applicable for the detachment of concave cells. Finally, we show that the rupture force of adherent cells is also highly sensitive to substrate stiffness, since an increase in substrate stiffness will lead to more associated bonds. These findings can provide insight into the critical role of cell volume in cell detachment and might have profound implications for other adhesion-related physiological processes.

  10. Non-Adherence to Study Time Management Strategies among NOUN Students and Implications for Academic Stress

    Science.gov (United States)

    Okopi, Fidel O.

    2011-01-01

    The study was designed to investigate the NOUN students' non-adherence to their time management strategies (TMS) during the course of their studies. The researcher also wanted to find out whether their gender, age, marital and employment statuses have influence on their adherence/non-adherence to the plan or not. The researcher also examined the…

  11. Non-adherence to anti-retroviral therapy among HIV infected adults in Mon State of Myanmar

    Directory of Open Access Journals (Sweden)

    Win Lei Aye

    2017-05-01

    Full Text Available Abstract Background The provision of Anti-Retroviral Therapy (ART was started in Myanmar in 2005 in collaboration with the National AIDS Program and the private sector. Successful clinical management of HIV-infected patients is subject to optimal adherence. The aim of the study was to determine the prevalence of adherence to ART and identify factors associated with non-adherence to ART among HIV infected adults registered in a private sector setting in Mon State, Myanmar. Methods This cross-sectional study was conducted with adults living with HIV receiving ART at an HIV outpatient clinic between April and May 2016. A total of three hundred People Living with HIV(PLHIV were interviewed using a pretested and structured questionnaire. The 30 days Visual Analog Scale (VAS adherence instrument was used to assess the level of adherence. Multivariable logistic regression analysis was used to determine factors associated with non-adherence to ART. Results Among 300 patients (male 37.7% and female 62.3%, with a mean age of 41.3 years, standard deviation 8.7, 84% reported ≥95% adherence to ART in the past month. Among 16% of those reporting non-adherence, major reasons for skipping the medication were being busy (23%, being away from home (17.7% and being forgetful (12.3%. In multivariable logistic rgeression, low behavioural skills on ART adherence (OR = 0.31, 95% CI: 0.10-0.94, tobacco use (OR = 3.22, 95% CI:1.28-8.12, having disclosed their HIV status (OR = 0.07, 95% CI: 0.01-0.69, having a partner who was not on ART (OR = 4.25, 95% CI: 1.70-10.64 and among men, having erectile dysfunction (OR = 15.14, 95% CI: 1.41-162.66 were significant associated with ART non-adherence. Conclusion Non-adherence to ART was associated with individual moderating factors and behavioral skills. Priority measures such as addressing risk behaviour and behavioural change communication tailored to individual patients’ lifestyles requires comprehensive

  12. Non-adherence to anti-retroviral therapy among HIV infected adults in Mon State of Myanmar.

    Science.gov (United States)

    Aye, Win Lei; Puckpinyo, Apa; Peltzer, Karl

    2017-05-05

    The provision of Anti-Retroviral Therapy (ART) was started in Myanmar in 2005 in collaboration with the National AIDS Program and the private sector. Successful clinical management of HIV-infected patients is subject to optimal adherence. The aim of the study was to determine the prevalence of adherence to ART and identify factors associated with non-adherence to ART among HIV infected adults registered in a private sector setting in Mon State, Myanmar. This cross-sectional study was conducted with adults living with HIV receiving ART at an HIV outpatient clinic between April and May 2016. A total of three hundred People Living with HIV(PLHIV) were interviewed using a pretested and structured questionnaire. The 30 days Visual Analog Scale (VAS) adherence instrument was used to assess the level of adherence. Multivariable logistic regression analysis was used to determine factors associated with non-adherence to ART. Among 300 patients (male 37.7% and female 62.3%, with a mean age of 41.3 years, standard deviation 8.7), 84% reported ≥95% adherence to ART in the past month. Among 16% of those reporting non-adherence, major reasons for skipping the medication were being busy (23%), being away from home (17.7%) and being forgetful (12.3%). In multivariable logistic rgeression, low behavioural skills on ART adherence (OR = 0.31, 95% CI: 0.10-0.94), tobacco use (OR = 3.22, 95% CI:1.28-8.12), having disclosed their HIV status (OR = 0.07, 95% CI: 0.01-0.69), having a partner who was not on ART (OR = 4.25, 95% CI: 1.70-10.64) and among men, having erectile dysfunction (OR = 15.14, 95% CI: 1.41-162.66) were significant associated with ART non-adherence. Non-adherence to ART was associated with individual moderating factors and behavioral skills. Priority measures such as addressing risk behaviour and behavioural change communication tailored to individual patients' lifestyles requires comprehensive interventions to improve adherence.

  13. Intentional and inadvertent non-adherence in adult coeliac disease. A cross-sectional survey.

    Science.gov (United States)

    Hall, Nicola J; Rubin, Gregory P; Charnock, Anne

    2013-09-01

    Adherence to a gluten-free diet is the mainstay of treatment for coeliac disease. Non-adherence is common as the diet is restrictive and can be difficult to follow. This study aimed to determine the rates of intentional and inadvertent non-adherence in adult coeliac disease and to examine the factors associated with both. A self-completion questionnaire was mailed to adult coeliac patients identified from the computer records of 31 family practices within the North East of England. We received 287 responses after one reminder. Intentional gluten consumption was reported by 115 (40%) of respondents. 155 (54%) had made at least one known mistaken lapse over the same period and 82 (29%) reported neither intentional nor mistaken gluten consumption. Using logistic regression analysis, low self-efficacy, perceptions of tolerance to gluten and intention were found to be independently predictive of intentional gluten consumption. A statistical model predicted 71.8% of cases reporting intentional lapses. Intentional non-adherence to the GFD was found to be common but not as frequent as inadvertent lapses. Distinguishing the factors influencing both intentional and inadvertent non-adherence is useful in understanding dietary self-management in coeliac disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Development of new concepts of non-adherence measurements among users of antihypertensives medicines

    DEFF Research Database (Denmark)

    Kjeldsen, Lene Juel; Bjerrum, Lars; Herborg, Hanne

    2011-01-01

    based on responses to questions. MAIN OUTCOME MEASURES: Medication-taking behaviour and self-efficacy (beliefs about ability and capacity to accomplish a task), respectively. Other measures of non-adherence collected by questionnaire were also addressed in the data for comparison of prevalence...... respectively. The prevalence of the adherence behaviour components were found to be between 10.3 and 34.9%, which is in the range of expected values. Associations between the new concepts of non-adherence measurement and characteristics of nonadherers remain to be established and would be a subject for further...

  15. Microfluidic bioreactors for culture of non-adherent cells

    DEFF Research Database (Denmark)

    Shah, Pranjul Jaykumar; Vedarethinam, Indumathi; Kwasny, Dorota

    2011-01-01

    Microfluidic bioreactors (μBR) are becoming increasingly popular for cell culture, sample preparation and analysis in case of routine genetic and clinical diagnostics. We present a novel μBR for non-adherent cells designed to mimic in vivo perfusion of cells based on diffusion of media through...

  16. Tackling medication non-adherence in severe mental illness: where are we going wrong?

    Science.gov (United States)

    Brown, E; Gray, R

    2015-04-01

    Although people with schizophrenia require medication to manage symptoms such as hearing voices, most do not take it as prescribed (they are non-adherent). We talked to psychiatrists, nurses and pharmacists about how they work with patients to help them be better at sticking with their medication. Although the professionals that we talked to recognized that treatment adherence was a major issue in their clinical work, they did not make best use of evidence-based interventions to address the problem. Often their practice was based on what they believed would work (e.g. patient education) even when the research shows that way of working to be ineffective. As far as we can determine, this is the first study to examine what interventions different mental health professionals report that they use in clinical practice to address patient's medication non-adherence. Non-adherence with medication is common in patients with schizophrenia. Addressing adherence to treatment may enhance clinical outcomes. Our aim was to explore mental health professionals experience and practise managing medication adherence in patients with schizophrenia. In this qualitative study, we interviewed mental health professionals from three key groups involved in promoting adherence: pharmacists, psychiatrists and nurses. Interviews were transcribed and analysed using a thematic approach. Thirty-five health professionals participated. From these interviews, we identified five main themes: my beliefs inform my practice; withholding information; adherence is important; who is responsible for promoting adherence?; and is it ok to pay people to take medication? Our overarching meta-theme was that practice with regard to promoting adherence was informed by beliefs and not by evidence. To the best of our knowledge, this is the first study to explore different mental health professionals' approaches to working with patients who do not want to take medication. The significance of participants' personal

  17. Efficient recyclable organic solar cells on cellulose nanocrystal substrates with a conducting polymer top electrode deposited by film-transfer lamination

    Science.gov (United States)

    Yinhua Zhou; Talha M. Khan; Jen-Chieh Liu; Canek Fuentes-Hernandez; Jae Won Shim; Ehsan Najafabadi; Jeffrey P. Youngblood; Robert J. Moon; Bernard Kippelen

    2014-01-01

    We report on efficient solar cells on recyclable cellulose nanocrystal (CNC) substrates with a new device structure wherein polyethylenimine-modified Ag is used as the bottom electron-collecting electrode and high-conductivity poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS, PH1000) is used as the semitransparent top holecollecting electrode. The...

  18. Graphene electrodes for stimulation of neuronal cells

    International Nuclear Information System (INIS)

    Koerbitzer, Berit; Nick, Christoph; Thielemann, Christiane; Krauss, Peter; Yadav, Sandeep; Schneider, Joerg J

    2016-01-01

    Graphene has the ability to improve the electrical interface between neuronal cells and electrodes used for recording and stimulation purposes. It provides a biocompatible coating for common electrode materials such as gold and improves the electrode properties. Graphene electrodes are also prepared on SiO 2 substrate to benefit from its optical properties like transparency. We perform electrochemical and Raman characterization of gold electrodes with graphene coating and compare them with graphene on SiO 2 substrate. It was found that the substrate plays an important role in the performance of graphene and show that graphene on SiO 2 substrate is a very promising material combination for stimulation electrodes. (paper)

  19. Risk Factors for Non-Adherence to cART in Immigrants with HIV Living in the Netherlands: Results from the ROtterdam ADherence (ROAD Project.

    Directory of Open Access Journals (Sweden)

    Sabrina K Been

    Full Text Available In the Netherlands, immigrant people living with HIV (PLWH have poorer psychological and treatment outcomes than Dutch PLWH. This cross-sectional field study examined risk factors for non-adherence to combination Antiretroviral Therapy (cART among immigrant PLWH. First and second generation immigrant PLWH attending outpatient clinics at two HIV-treatment centers in Rotterdam were selected for this study. Socio-demographic and clinical characteristics for all eligible participants were collected from an existing database. Trained interviewers subsequently completed questionnaires together with consenting participants (n = 352 to gather additional data on socio-demographic characteristics, psychosocial variables, and self-reported adherence to cART. Univariable and multivariable logistic regression analyses were conducted among 301 participants who had used cART ≥6 months prior to inclusion. Independent risk factors for self-reported non-adherence were (I not having attended formal education or only primary school (OR = 3.25; 95% CI: 1.28-8.26, versus University, (II experiencing low levels of social support (OR = 2.56; 95% CI: 1.37-4.82, and (III reporting low treatment adherence self-efficacy (OR = 2.99; 95% CI: 1.59-5.64. Additionally, HIV-RNA >50 copies/ml and internalized HIV-related stigma were marginally associated (P<0.10 with non-adherence (OR = 2.53; 95% CI: 0.91-7.06 and OR = 1.82; 95% CI: 0.97-3.43. The findings that low educational attainment, lack of social support, and low treatment adherence self-efficacy are associated with non-adherence point to the need for tailored supportive interventions. Establishing contact with peer immigrant PLWH who serve as role models might be a successful intervention for this specific population.

  20. Cost and clinical consequence of antibiotic non-adherence in acute exacerbations of chronic bronchitis.

    Science.gov (United States)

    Sorensen, S V; Baker, T; Fleurence, R; Dixon, J; Roberts, C; Haider, S; Hughes, D

    2009-08-01

    To quantify the impact of non-adherence on the clinical effectiveness of antibiotics for acute exacerbations of chronic bronchitis (AECB) and to estimate the economic consequences for Spain, Italy and the United States. Standard systematic reviewing procedures were followed to identify randomised controlled clinical trials of antibiotic treatment for acute respiratory tract infection for which adherence was reported. A decision-analytic model was then constructed to evaluate the impact of non-adherence to antibiotic treatment on clinical effectiveness and costs per AECB episode. The model compared the total treatment costs, cure rates and incremental costs per cure for a poor compliance group (PCG) against a good compliance group (GCG). Clinical and resource use estimates were from the published literature and physician surveys. Twenty-five articles met the criteria of the systematic review, although only one reported treatment success by adherence status. The relative risk of clinical effectiveness if non-adherent was 0.75 (95%CI 0.73-0.78). Based on this single study, the model predicted that 16-29% more patients would be cured in the GCG vs. the PCG, and payers would save up to euro122, euro179 and US$141 per AECB episode in Spain, Italy and the United States, respectively. Non-adherence to antibiotics for AECB may have an impact on clinical effectiveness, which is associated with increased costs.

  1. Methods of making membrane electrode assemblies

    Science.gov (United States)

    Kim, Yu Seung; Lee, Kwan -Soo; Rockward, Tommy Q. T.

    2015-07-28

    Method of making a membrane electrode assembly comprising: providing a membrane comprising a perfluorinated sulfonic acid; providing a first transfer substrate; applying to a surface of the first transfer substrate a first ink, said first ink comprising an ionomer and a catalyst; applying to the first ink a suitable non-aqueous swelling agent; forming an assembly comprising: the membrane; and the first transfer substrate, wherein the surface of the first transfer substrate comprising the first ink and the non-aqueous swelling agent is disposed upon one surface of the membrane; and heating the assembly at a temperature of 150.degree. C. or less and at a pressure of from about 250 kPa to about 3000 kPa or less for a time suitable to allow substantially complete transfer of the first ink and the second ink to the membrane; and cooling the assembly to room temperature and removing the first transfer substrate and the second transfer substrate.

  2. Method of adhering bone to a rigid substrate using a graphite fiber reinforced bone cement

    Science.gov (United States)

    Knoell, A. C.; Maxwell, H. G. (Inventor)

    1977-01-01

    A method is described for adhering bone to the surface of a rigid substrate such as a metal or resin prosthesis using an improved surgical bone cement. The bone cement has mechanical properties more nearly matched to those of animal bone and thermal curing characteristics which result in less traumatization of body tissues and comprises a dispersion of short high modulus graphite fibers within a bonder composition including polymer dissolved in reactive monomer such as polymethylmethacrylate dissolved in methylmethacrylate monomer.

  3. medication non-adherence among adult psychiatric out patients in

    African Journals Online (AJOL)

    GB

    2013-11-03

    Nov 3, 2013 ... KEYWORDS: mental illness, non-adherence, Jimma University Specialized Hospital, Ethiopia .... first time, individuals who were so seriously ill that they could not respond to the ..... don't work when they are not taken. Aus. J.

  4. Self-reported non-adherence and beliefs about medication in a Swedish kidney transplant population.

    Science.gov (United States)

    Lennerling, Annette; Forsberg, Anna

    2012-01-01

    Patients' non-adherence to immunosuppressant treatment after organ transplantation may lead to organ failure, graft loss and death. Non-adherence among Swedish kidney transplant recipients has not previously been studied. Hence the aim of this study was to explore non-adherence among Swedish kidney transplant recipients by using self-report instruments as well as testing the hypothesis that there is a difference in self-reported symptoms, beliefs about medicine and social support between respondents with or without self reported non-adherence. In the present cross sectional study 250 renal transplant recipients participated by replying to a questionnaire. Two validated instruments were included, one on beliefs about medicine (the BMQ©), the other on nonadherence (the BAASIS©). Only 46 % never failed to follow the medical treatment with respect to taking the drugs, dosage or timing (>2 hrs from prescribed time). Timing was the most frequently reported deviation (48 %). Forty-seven patients (16 %) had failed taking at least one dose of the prescribed immunosuppressants during the past four weeks. Four individuals had reduced the prescribed doses. Only one reported taking a 'drug holiday'. Nine participants reported stronger concerns than necessities for immunosuppressive medication. For the BMQ the necessity scores were extremely high while the scores for concern were low. Risk behaviour identified by the BAASIS had no association in risk attitudes as identified in the BMQ. The only factor relating to non-adherence was lack of social support (p=0.022). In general adherence was high. Identification of the exceptions remains a challenge.

  5. Non-communicable diseases and adherence to Mediterranean diet.

    Science.gov (United States)

    Caretto, Antonio; Lagattolla, Valeria

    2015-01-01

    Non-communicable diseases (NCDs) also known as chronic diseases last for a long time and progress generally slow. Major non-communicable diseases are cardiovascular diseases, cancers, chronic respiratory diseases and diabetes. Unhealthy lifestyles and food behaviours play an important role for determining such diseases. The change in unhealthy behaviours or the maintenance of healthy lifestyles has enormous value in the reduction of diseases and longer life expectancy not only on an individual level but for the community as a whole. Recent meta-analyses reported Mediterranean diet to be an optimal diet when adopted as a whole, in order to preserve and maintain a good health status. A greater adherence score to the Mediterranean diet (2-point increase) was related to induce an 8% reduction in overall mortality, a 10% reduced risk of CVD and a 4% reduction in neoplastic diseases. However, there is no direct method in quantifying and evaluating adherence, therefore a large number of indirect indices in several studies have been proposed, with a last unifying score. Recently more and more e-health techniques such as web communication or desktop publishing (DVDs and so on) are being used, obtaining good results in the Mediterranean diet adherence. For successfully changing the unhealthy lifestyles and food behaviours of the population, interventions at all levels are needed with the cooperation of Institutions, mass media, agricultural and food industry and healthcare professionals guided by expert scientific societies.

  6. Adherence to antidepressants

    Directory of Open Access Journals (Sweden)

    Abimbola Farinde

    2013-01-01

    Full Text Available While major depression is considered a frequent mental illness there are ongoing reports of high non-adherence to antidepressant medications which places suffers at high risk for relapse, recurrence, or greater impairment,. The World Health Organization (WHO defines adherence as the extent to which a person′s behavior (e.g. taking medications can align with the agreed recommendations of a health care provider. Unfortunately while patient may recognize the importance of adherence to antidepressant medications the majority of patients do not adhere to their prescribed antidepressants. Some of the factors that may contribute to or lead to non-adherence include knowingly or unknowingly missing doses, taking extra doses, delaying administration times, or taking drug holidays. Pharmacists have the unique ability to deter non-adherence through the performance of continuous assessment and monitoring of adherence in this population given these accessibility. Additionally, pharmacists are able to develop therapeutic alliances with patients that can help to increase the likelihood of achieving positive patient outcomes. Antidepressant non-adherence can be viewed as a significant public health concern so it is important for patients to be educated about the importance of adherence, and health care professionals should be aware of factors or patient characteristics that can serve as barriers to non-adherence.

  7. What makes orphans in Kigali, Rwanda, non-adherent to antiretroviral therapy? Perspectives of their caregivers.

    Science.gov (United States)

    Kikuchi, Kimiyo; Poudel, Krishna C; Muganda, John; Sato, Tomoko; Mutabazi, Vincent; Muhayimpundu, Ribakare; Majyambere, Adolphe; Nyonsenga, Simon P; Sase, Eriko; Jimba, Masamine

    2014-01-01

    Every year, approximately 260,000 children are infected with HIV in low- and middle-income countries. The timely initiation and high level of maintenance of antiretroviral therapy (ART) are crucial to reducing the suffering of HIV-positive children. We need to develop a better understanding of the background of children's ART non-adherence because it is not well understood. The purpose of this study is to explore the background related to ART non-adherence, specifically in relation to the orphan status of children in Kigali, Rwanda. We conducted 19 focus group discussions with a total of 121 caregivers of HIV-positive children in Kigali. The primary data for analysis were verbatim transcripts and socio-demographic data. A content analysis was performed for qualitative data analysis and interpretation. The study found several contextual factors that influenced non-adherence: among double orphans, there was psychological distance between the caregivers and children, whereas economic burden was the primary issue among paternal orphans. The factors promoting adherence also were unique to each orphan status, such as the positive attitude about disclosing serostatus to the child by double orphans' caregivers, and feelings of guilt about the child's condition among non-orphaned caregivers. Knowledge of orphan status is essential to elucidate the factors influencing ART adherence among HIV-positive children. In this qualitative study, we identified the orphan-related contextual factors that influenced ART adherence. Understanding the social context is important in dealing with the challenges to ART adherence among HIV-positive children.

  8. Ultrafastly Interweaving Graphdiyne Nanochain on Arbitrary Substrates and Its Performance as a Supercapacitor Electrode.

    Science.gov (United States)

    Wang, Fan; Zuo, Zicheng; Shang, Hong; Zhao, Yingjie; Li, Yuliang

    2018-03-08

    A moderate method is first developed here for superfast (in seconds) growth of an ultrafine graphdiyne (GDY) nanochain on arbitrary substrates in the atmosphere. This is an environmentally friendly and metal-catalyst-free method, efficiently eliminating extraneous contaminations for the carbon materials. The seamless GDY coating on any substrates demonstrates that an all-carbon GDY possesses outstanding controllability and processability, perfectly compensating for the drawbacks of prevailing all-carbon materials. After the decoration of 3D GDY nanostructures, the substrates become superhydrophobic with contact angles high up to of 148° and can be used as outstanding frameworks for storing organic pollution. Because of the reasonable porous and 3D continuous features, the as-prepared samples can be applied as high-performance binder-free supercapacitor electrodes with high area capacitance of up to 53.66 mF cm -2 , prominent power performance, and robust long-term retention (99% after 1300 cycles).

  9. Robust and Recyclable Substrate Template with an Ultrathin Nanoporous Counter Electrode for Organic-Hole-Conductor-Free Monolithic Perovskite Solar Cells.

    Science.gov (United States)

    Li, Ming-Hsien; Yang, Yu-Syuan; Wang, Kuo-Chin; Chiang, Yu-Hsien; Shen, Po-Shen; Lai, Wei-Chih; Guo, Tzung-Fang; Chen, Peter

    2017-12-06

    A robust and recyclable monolithic substrate applying all-inorganic metal-oxide selective contact with a nanoporous (np) Au:NiO x counter electrode is successfully demonstrated for efficient perovskite solar cells, of which the perovskite active layer is deposited in the final step for device fabrication. Through annealing of the Ni/Au bilayer, the nanoporous NiO/Au electrode is formed in virtue of interconnected Au network embedded in oxidized Ni. By optimizing the annealing parameters and tuning the mesoscopic layer thickness (mp-TiO 2 and mp-Al 2 O 3 ), a decent power conversion efficiency (PCE) of 10.25% is delivered. With mp-TiO 2 /mp-Al 2 O 3 /np-Au:NiO x as a template, the original perovskite solar cell with 8.52% PCE can be rejuvenated by rinsing off the perovskite material with dimethylformamide and refilling with newly deposited perovskite. A renewed device using the recycled substrate once and twice, respectively, achieved a PCE of 8.17 and 7.72% that are comparable to original performance. This demonstrates that the novel device architecture is possible to recycle the expensive transparent conducting glass substrates together with all the electrode constituents. Deposition of stable multicomponent perovskite materials in the template also achieves an efficiency of 8.54%, which shows its versatility for various perovskite materials. The application of such a novel NiO/Au nanoporous electrode has promising potential for commercializing cost-effective, large scale, and robust perovskite solar cells.

  10. A Flexible Multiring Concentric Electrode for Non-Invasive Identification of Intestinal Slow Waves

    Directory of Open Access Journals (Sweden)

    Victor Zena-Giménez

    2018-01-01

    Full Text Available Developing new types of optimized electrodes for specific biomedical applications can substantially improve the quality of the sensed signals. Concentric ring electrodes have been shown to provide enhanced spatial resolution to that of conventional disc electrodes. A sensor with different electrode sizes and configurations (monopolar, bipolar, etc. that provides simultaneous records would be very helpful for studying the best signal-sensing arrangement. A 5-pole electrode with an inner disc and four concentric rings of different sizes was developed and tested on surface intestinal myoelectrical recordings from healthy humans. For good adaptation to a curved body surface, the electrode was screen-printed onto a flexible polyester substrate. To facilitate clinical use, it is self-adhesive, incorporates a single connector and can perform dry or wet (with gel recordings. The results show it to be a versatile electrode that can evaluate the optimal configuration for the identification of the intestinal slow wave and reject undesired interference. A bipolar concentric record with an outer ring diameter of 30 mm, a foam-free adhesive material, and electrolytic gel gave the best results.

  11. Tungsten as a Chemically-Stable Electrode Material on Ga-Containing Piezoelectric Substrates Langasite and Catangasite for High-Temperature SAW Devices

    Directory of Open Access Journals (Sweden)

    Gayatri K. Rane

    2016-02-01

    Full Text Available Thin films of tungsten on piezoelectric substrates La3Ga5SiO14 (LGS and Ca3TaGa3Si2O14 (CTGS have been investigated as a potential new electrode material for interdigital transducers for surface acoustic wave-based sensor devices operating at high temperatures up to 800 °C under vacuum conditions. Although LGS is considered to be suitable for high-temperature applications, it undergoes chemical and structural transformation upon vacuum annealing due to diffusion of gallium and oxygen. This can alter the device properties depending on the electrode nature, the annealing temperature, and the duration of the application. Our studies present evidence for the chemical stability of W on these substrates against the diffusion of Ga/O from the substrate into the film, even upon annealing up to 800 °C under vacuum conditions using Auger electron spectroscopy and energy-dispersive X-ray spectroscopy, along with local studies using transmission electron microscopy. Additionally, the use of CTGS as a more stable substrate for such applications is indicated.

  12. Risk factors for non-adherence to antidepressant treatment in patients with mood disorders.

    Science.gov (United States)

    De las Cuevas, Carlos; Peñate, Wenceslao; Sanz, Emilio J

    2014-01-01

    Adherence to antidepressant therapy by patients with depressive disorders is essential not only to achieve a positive patient outcome but also to prevent a relapse. The aim of this study was to identify potential modelling factors influencing adherence to antidepressant treatment by patients with mood disorders in the community mental health care setting A total of 160 consecutive psychiatric outpatients attending two Community Mental Health Centres on Tenerife Island between September 2011 and May 2012 were asked to participate in the study; of these, 145 accepted. The Morisky self-report scale was used to assess adherence. The potential predictors examined included socio-demographic, clinical and therapeutic variables. The Clinical Global Impression-Severity and -Improvement scales and the Beck Depression Inventory were used for clinical assessment. Drug treatment side-effects were assessed using the "Self-report Antidepressant Side-Effect Checklist." All participants were also asked to complete the "Drug Attitude Inventory" (DAI), "Beliefs about Medicine Questionnaire" (BMQ), and "Leeds Attitude towards concordance Scale". Discriminant analyses were performed to predict non-adherence. There was no clear correlation between adherence and the socio-demographic variables examined, but adherence was related to a positive attitude of the patients towards his/her treatment (DAI) and low scores in the BMQ-Harm and -Concern subscales. Non-adherence was also related to an increasing severity of depression and to the presence and severity of side-effects. Among our study cohort, the profiles of adherent patients to antidepressant treatment were more closely associated with each patient's attitudes and beliefs than to objective socio-demographic variables. The severity of depression played a relevant role in adherence, but whether this role is direct or an interaction with several concurrent factors is not yet clear. Side-effects were also closely related to adherence, as

  13. Integration substrate with a ultra-high-density capacitor and a through-substrate via

    NARCIS (Netherlands)

    Klootwijk, J.H.; Roozeboom, F.; Ruigrok, J.J.M.; Reefman, D.

    2014-01-01

    An integration substrate for a system in package comprises a through-substrate via and a trench capacitor wherein with a trench filling that includes at least four electrically conductive capacitor-electrode layers in an alternating arrangement with dielectric layers. --The capacitor-electrode

  14. Medication understanding, non-adherence, and clinical outcomes among adult kidney transplant recipients.

    Science.gov (United States)

    Patzer, Rachel E; Serper, Marina; Reese, Peter P; Przytula, Kamila; Koval, Rachel; Ladner, Daniela P; Levitsky, Josh M; Abecassis, Michael M; Wolf, Michael S

    2016-10-01

    We sought to evaluate the prevalence of medication understanding and non-adherence of entire drug regimens among kidney transplantation (KT) recipients and to examine associations of these exposures with clinical outcomes. Structured, in-person interviews were conducted with 99 adult KT recipients between 2011 and 2012 at two transplant centers in Chicago, IL; and Atlanta, GA. Nearly, one-quarter (24%) of participants had limited literacy as measured by the Rapid Estimate of Adult Literacy in Medicine test; patients took a mean of 10 (SD=4) medications and 32% had a medication change within the last month. On average, patients knew what 91% of their medications were for (self-report) and demonstrated proper dosing (via observed demonstration) for 83% of medications. Overall, 35% were non-adherent based on either self-report or tacrolimus level. In multivariable analyses, fewer months since transplant and limited literacy were associated with non-adherence (all Padherence, and hospitalization could help target appropriate self-care interventions. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Does cognitive impairment impact adherence? A systematic review and meta-analysis of the association between cognitive impairment and medication non-adherence in stroke.

    LENUS (Irish Health Repository)

    Rohde, Daniela

    2017-12-08

    While medication adherence is essential for the secondary prevention of stroke, it is often sub-optimal, and can be compromised by cognitive impairment. This study aimed to systematically review and meta-analyse the association between cognitive impairment and medication non-adherence in stroke.

  16. Pulsed laser deposition of transparent conductive oxide thin films on flexible substrates

    Science.gov (United States)

    Socol, G.; Socol, M.; Stefan, N.; Axente, E.; Popescu-Pelin, G.; Craciun, D.; Duta, L.; Mihailescu, C. N.; Mihailescu, I. N.; Stanculescu, A.; Visan, D.; Sava, V.; Galca, A. C.; Luculescu, C. R.; Craciun, V.

    2012-11-01

    The influence of target-substrate distance during pulsed laser deposition of indium zinc oxide (IZO), indium tin oxide (ITO) and aluminium-doped zinc oxide (AZO) thin films grown on polyethylene terephthalate (PET) substrates was investigated. It was found that the properties of such flexible transparent conductive oxide (TCO)/PET electrodes critically depend on this parameter. The TCO films that were deposited at distances of 6 and 8 cm exhibited an optical transmittance higher than 90% in the visible range and electrical resistivities around 5 × 10-4 Ω cm. In addition to these excellent electrical and optical characteristics the films grown at 8 cm distance were homogenous, smooth, adherent, and without cracks or any other extended defects, being suitable for opto-electronic device applications.

  17. Integration substrate with a ultra-high-density capacitor and a through-substrate via

    NARCIS (Netherlands)

    2008-01-01

    An integration substrate for a system in package comprises a through-substrate via and a trench capacitor wherein with a trench filling that includes at least 4 elec. conductive capacitor-electrode layers in an alternating arrangement with dielec. layers. The capacitor-electrode layers are

  18. Identifying psychosocial predictors of medication non-adherence following acute coronary syndrome: A systematic review and meta-analysis.

    Science.gov (United States)

    Crawshaw, Jacob; Auyeung, Vivian; Norton, Sam; Weinman, John

    2016-11-01

    Medication non-adherence following acute coronary syndrome (ACS) is associated with poor clinical outcomes. A systematic review and meta-analysis were undertaken to identify psychosocial factors associated with medication adherence in patients with ACS. A search of electronic databases (Cochrane Library, Medline, EMBASE, PsycINFO, Web of Science, International Pharmaceutical Abstracts, CINAHL, ASSIA, OpenGrey, EthOS and WorldCat) was undertaken to identify relevant articles published in English between 2000 and 2014. Articles were screened against our inclusion criteria and data on study design, sample characteristics, predictors, outcomes, analyses, key findings and study limitations were abstracted. Our search identified 3609 records, of which 17 articles met our inclusion criteria (15 independent studies). Eight out of ten studies found an association between depression and non-adherence. A meta-analysis revealed that depressed patients were twice as likely to be non-adherent compared to patients without depression (OR=2.00, 95% CI 1.57-3.33, p=0.015). Type D personality was found to predict non-adherence in both studies in which it was measured. Three out of three studies reported that treatment beliefs based on the Necessity-Concerns Framework predicted medication non-adherence and there was some evidence that social support was associated with better adherence. There was insufficient data to meta-analyse all other psychosocial factors identified. There was some evidence that psychosocial factors, particularly depression, were associated with medication adherence following ACS. Targeting depressive symptoms, screening for Type D personality, challenging maladaptive treatment beliefs, and providing better social support for patients may be useful strategies to improve medication adherence. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  19. Highly enhanced electrochemical activity of Ni foam electrodes decorated with nitrogen-doped carbon nanotubes for non-aqueous redox flow batteries

    Science.gov (United States)

    Lee, Jungkuk; Park, Min-Sik; Kim, Ki Jae

    2017-02-01

    Nitrogen-doped carbon nanotubes (NCNTs) are directly grown on the surface of a three-dimensional (3D) Ni foam substrate by floating catalytic chemical vapor deposition (FCCVD). The electrochemical properties of the 3D NCNT-Ni foam are thoroughly examined as a potential electrode for non-aqueous redox flow batteries (RFBs). During synthesis, nitrogen atoms can be successfully doped onto the carbon nanotube (CNT) lattices by forming an abundance of nitrogen-based functional groups. The 3D NCNT-Ni foam electrode exhibits excellent electrochemical activities toward the redox reactions of [Fe (bpy)3]2+/3+ (in anolyte) and [Co(bpy)3]+/2+ (in catholyte), which are mainly attributed to the hierarchical 3D structure of the NCNT-Ni foam electrode and the catalytic effect of nitrogen atoms doped onto the CNTs; this leads to faster mass transfer and charge transfer during operation. As a result, the RFB cell assembled with 3D NCNT-Ni foam electrodes exhibits a high energy efficiency of 80.4% in the first cycle; this performance is maintained up to the 50th cycle without efficiency loss.

  20. Virtual electrodes for high-density electrode arrays

    Science.gov (United States)

    Cela, Carlos J.; Lazzi, Gianluca

    2015-10-13

    The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

  1. Self-efficacy beliefs, locus of control, religiosity and non-adherence to immunosuppressive medications in kidney transplant patients.

    Science.gov (United States)

    Silva, Andresa Nascimento; Moratelli, Lucas; Tavares, Paula Liziero; Marsicano, Elisa De Oliveira; Pinhati, Renata Romanholi; Colugnati, Fernando Antonio Basile; Lucchetti, Giancarlo; Sanders-Pinheiro, Helady

    2016-11-01

    Adherence to immunosuppressive medication is essential for favourable kidney transplant outcomes. The present study aims to investigate how self-efficacy beliefs, health locus of control and religiosity are associated with adherence to immunosuppressives in post kidney transplant recipients. This is a cross-sectional study with 88 recipients with more than 1 year after transplantation. Three methods were used to classify patients as adherent or non-adherent: Basel Assessment of Adherence Scale for Immunosuppressives - BAASIS, the collateral report and blood levels of immunosuppressive medications. Self-efficacy, health locus of control, and religiosity were evaluated applying General Perceived Self-Efficacy Scale, Multidimensional Health Locus of Control Scale and Duke University Religion Index, respectively. Non-adherence was modelled by uni- and multivariated analysis. Sixty-three percent of the patients were male, age 47.2 ± 12.9 years, and median post-transplant time 108.71 (49.0-266.0) months. We found 70.5% of patients were non-adherent through at least one method. Adherent patients presented higher self-efficacy scores (45.1 ± 4.9 vs 38.3 ± 8.6; P locus of control (OR 1.23, IC 1.04-1.45, P = 0.016) and lower intrinsic religiosity (OR 0.56, IC 0.38-0.84, P = 0.006). Our study showed that self-efficacy, chance locus of control, and intrinsic religiosity were associated with non-adherence to immunosuppressives. A broader perception of the kidney transplant patient´s integrality can help health professionals to design strategies to promote adherence in this population. © 2015 Asian Pacific Society of Nephrology.

  2. Prevalence and correlates of non-adherence to immunosuppressants and to health behaviours in patients after kidney transplantation in Brazil - the ADHERE BRAZIL multicentre study: a cross-sectional study protocol.

    Science.gov (United States)

    Sanders-Pinheiro, Helady; Colugnati, Fernando Antonio Basile; Marsicano, Elisa Oliveira; De Geest, Sabina; Medina, José Osmar Pestana

    2018-02-20

    Non-adherence to immunosuppressive therapy is a prevalent risk factor for poor clinical and after kidney transplantation (KT), and has contributed to the lack of improvement in long-term graft survival over the past decade. Understanding the multilevel correlates and risk factors of non-adherence is crucial to determine the optimal level for planning interventions, namely at the patient, health care provider, KT centre, and health care system level. Brazil, having the largest public transplantation program in the world and with regional differences regarding access to health services and service implementation, is in a unique position to study this multilevel approach. Therefore, the Adhere Brazil Study (ADHERE BRAZIL) was designed to assess the prevalence and variability of non-adherence to immunosuppressants and to health behaviours among adult KT recipients in Brazil, and to assess the multilevel correlates of non-adherence to immunosuppressive medication. We describe the rationale, design, and methodology of the ADHERE BRAZIL study. This is an observational, cross-sectional, multicentre study that includes 20 Brazilian KT centres. A stratified sampling approach is used, based on strata, with the following characteristics considered: geographical region and transplant activity (number of KTs per year). A random sample of patients (proportional to the size of the centre within each stratum) is selected from each centre. The prevalence of different health behaviours is assessed through self-report. The assessment of multilevel correlates of non-adherence is guided by the ecological model that considers factors at the level of the patient, health-care professional, and transplant centre, using established instruments or instruments developed for this study. Data will be collected over an 18-month period, with information obtained during the regular follow-up visits to the transplant outpatient clinic and directly entered into the Research Electronic Data Capture

  3. Flexible indium zinc oxide/Ag/indium zinc oxide multilayer electrode grown on polyethersulfone substrate by cost-efficient roll-to-roll sputtering for flexible organic photovoltaics

    International Nuclear Information System (INIS)

    Park, Yong-Seok; Kim, Han-Ki

    2010-01-01

    The authors describe the preparation and characteristics of flexible indium zinc oxide (IZO)-Ag-IZO multilayer electrodes grown on flexible polyethersulfone (PES) substrates using a roll-to-roll sputtering system for use in flexible organic photovoltaics. By the continuous roll-to-roll sputtering of the bottom IZO, Ag, and top IZO layers at room temperature, they were able to fabricate a high quality IZO-Ag-IZO multilayer electrode with a sheet resistance of 6.15 ε/square, optical transmittance of 87.4%, and figure of merit value of 42.03x10 -3 Ω -1 on the PES substrate. In addition, the IZO-Ag-IZO multilayer electrode exhibited superior flexibility to the roll-to-roll sputter grown single ITO electrode due to the existence of a ductile Ag layer between the IZO layers and stable amorphous structure of the IZO film. Furthermore, the flexible organic solar cells (OSCs) fabricated on the roll-to-roll sputter grown IZO-Ag-IZO electrode showed higher power efficiency (3.51%) than the OSCs fabricated on the roll-to-roll sputter grown single ITO electrode (2.67%).

  4. Does fasting during Ramadan trigger non-adherence to oral hormonal therapy in breast cancer patients?

    Science.gov (United States)

    Zeeneldin, Ahmed Abdelmabood; Gaber, Ayman Abdelsamee; Taha, Fatma Mohamed

    2012-09-01

    To estimate the effect of fasting during Ramadan (the ninth lunar month) on adherence to oral hormonal therapies (OHT) among breast cancer (BC) patients. During Ramadan 2010, 139 BC patients were interviewed at the Egyptian National Cancer Institute. They were asked about fasting as well as intake of OHT in Ramadan and in the preceding month. The median age was 50years and most patients were postmenopausal with good performance status and non-metastatic disease. The median number of fasting days was 18% and 93% of patients were fasting 80% or more of Ramadan. Tamoxifen and aromatase inhibitors were used in 64% and 36%, respectively. Adherence to OHT during Ramadan and its preceding month were 94.2% and 95.7%, respectively (p=0.77). In univariate analysis, non-adherence prior to Ramadan and shorter duration of OHT were predictors of non-adherence during Ramadan (PRamadan, this does not negatively impact compliance with treatment. Copyright © 2012. Published by Elsevier B.V.

  5. Does fasting during Ramadan trigger non-adherence to oral hormonal therapy in breast cancer patients?

    International Nuclear Information System (INIS)

    Zeeneldin, A.A.; Gaber, A.A.; Taha, F.M.

    2012-01-01

    Purpose: To estimate the effect of fasting during Ramadan (the ninth lunar month) on adherence to oral hormonal therapies (OHT) among breast cancer (BC) patients. Patients and Methods: During Ramadan 2010, 139 BC patients were interviewed at the Egyptian National Cancer Institute. They were asked about fasting as well as intake of OHT in Ramadan and in the preceding month. Results: The median age was 50 years and most patients were postmenopausal with good performance status and non-metastatic disease. The median number of fasting days was 18% and 93% of patients were fasting 80% or more of Ramadan. Tamoxifen and aromatase inhibitors were used in 64% and 36%, respectively. Adherence to OHT during Ramadan and its preceding month were 94.2% and 95.7%, respectively (p = 0.77). In univariate analysis, non-adherence prior to Ramadan and shorter duration of OHT were predictors of non-adherence during Ramadan (P < 0.001, 0.003, respectively). Fasting, age, performance status, presence of metastases and type of hormonal therapy were not good predictors of adherence. Conclusions: While most of patients receiving OHT for BC are fasting during Ramadan, this does not negatively impact compliance with treatment

  6. Toward Plastic Smart Windows: Optimization of Indium Tin Oxide Electrodes for the Synthesis of Electrochromic Devices on Polycarbonate Substrates.

    Science.gov (United States)

    Laurenti, Marco; Bianco, Stefano; Castellino, Micaela; Garino, Nadia; Virga, Alessandro; Pirri, Candido F; Mandracci, Pietro

    2016-03-01

    Plastic smart windows are becoming one of the key elements in view of the fabrication of inexpensive, lightweight electrochromic (EC) devices to be integrated in the new generation of high-energy-efficiency buildings and automotive applications. However, fabricating electrochromic devices on polymer substrates requires a reduction of process temperature, so in this work we focus on the development of a completely room-temperature deposition process aimed at the preparation of ITO-coated polycarbonate (PC) structures acting as transparent and conductive plastic supports. Without providing any substrate heating or surface activation pretreatments of the polymer, different deposition conditions are used for growing indium tin oxide (ITO) thin films by the radiofrequency magnetron sputtering technique. According to the characterization results, the set of optimal deposition parameters is selected to deposit ITO electrodes having high optical transmittance in the visible range (∼90%) together with low sheet resistance (∼8 ohm/sq). The as-prepared ITO/PC structures are then successfully tested as conductive supports for the fabrication of plastic smart windows. To this purpose, tungsten trioxide thin films are deposited by the reactive sputtering technique on the ITO/PC structures, and the resulting single electrode EC devices are characterized by chronoamperometric experiments and cyclic voltammetry. The fast switching response between colored and bleached states, together with the stability and reversibility of their electrochromic behavior after several cycling tests, are considered to be representative of the high quality of the EC film but especially of the ITO electrode. Indeed, even if no adhesion promoters, additional surface activation pretreatments, or substrate heating were used to promote the mechanical adhesion among the electrode and the PC surface, the observed EC response confirmed that the developed materials can be successfully employed for the

  7. Exploring risk factors of non-adherence to immunosuppressive medication in kidney transplant recipients : improving methodology & reorienting research goals

    OpenAIRE

    Denhaerynck, Kris

    2006-01-01

    8.1. Background and aim of the research program Non-adherence to the immunosuppressive therapy is an important issue in kidney transplant patients. About 20% of the kidney transplant patients are non-adherent to the immunosuppressive regimen. Non-adherence contributes to 20% of late acute rejection episodes and 16% of the graft losses, and results in a decreased number of quality adjusted life years. A strategy to increase long-term successful outcome after transplantation i...

  8. Electrostatic spray deposition of highly transparent silver nanowire electrode on flexible substrate.

    Science.gov (United States)

    Kim, Taegeon; Canlier, Ali; Kim, Geun Hong; Choi, Jaeho; Park, Minkyu; Han, Seung Min

    2013-02-01

    In this work, a modified polyol synthesis by adding KBr and by replacing the AgCl with NaCl seed was used to obtain high quality silver nanowires with long aspect ratios with an average length of 13.5 μm in length and 62.5 nm in diameter. The Ag nanowires suspended in methanol solution after removing any unwanted particles using a glass filter system were then deposited on a flexible polycarbonate substrate using an electrostatic spray system. Transmittance of 92.1% at wavelength of 550 nm with sheet resistance of 20 Ω/sq and haze of 4.9% were measured for the electrostatic sprayed Ag nanowire transparent electrode.

  9. Non-invasive and non-destructive measurements of confluence in cultured adherent cell lines.

    Science.gov (United States)

    Busschots, Steven; O'Toole, Sharon; O'Leary, John J; Stordal, Britta

    2015-01-01

    Many protocols used for measuring the growth of adherent monolayer cells in vitro are invasive, destructive and do not allow for the continued, undisturbed growth of cells within flasks. Protocols often use indirect methods for measuring proliferation. Microscopy techniques can analyse cell proliferation in a non-invasive or non-destructive manner but often use expensive equipment and software algorithms. In this method images of cells within flasks are captured by photographing under a standard inverted phase contract light microscope using a digital camera with a camera lens adaptor. Images are analysed for confluence using ImageJ freeware resulting in a measure of confluence known as an Area Fraction (AF) output. An example of the AF method in use on OVCAR8 and UPN251 cell lines is included. •Measurements of confluence from growing adherent cell lines in cell culture flasks is obtained in a non-invasive, non-destructive, label-free manner.•The technique is quick, affordable and eliminates sample manipulation.•The technique provides an objective, consistent measure of when cells reach confluence and is highly correlated to manual counting with a haemocytometer. The average correlation co-efficient from a Spearman correlation (n = 3) was 0.99 ± 0.008 for OVCAR8 (p = 0.01) and 0.99 ± 0.01 for UPN251 (p = 0.01) cell lines.

  10. Non-adherence to life-style modification and its factors among type 2 diabetic patients

    OpenAIRE

    Shirin Jahan Mumu; Farzana Saleh; Ferdous Ara; Fadia Afnan; Liaquat Ali

    2014-01-01

    Non-adherence to preventive and therapeutic life-style recommendations among patients with diabetes is special challenge in the management of these patients. This study aimed to measure the proportion of non-adherence to life-style modification and factors associated with these among a group of Bangladeshi type 2 diabetic patients. Under an analytical cross-sectional design 374 type 2 diabetic patients (age >20 years), diagnosed for at least 1 year, were selected from different health care ce...

  11. Multilevel Correlates of Non-Adherence in Kidney Transplant Patients Benefitting from Full Cost Coverage for Immunosuppressives: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Elisa Oliveira Marsicano

    Full Text Available Adherence is the result of the interaction of the macro, meso, micro, and patient level factors. The macro level includes full coverage of immunosuppressive medications as is the case in Brazil. We studied the correlates of immunosuppressive non-adherence in post kidney transplant patients in the Brazilian health care system.Using a cross-sectional design, adherence to immunosuppressives was assessed in a sample of 100 kidney transplant patients using a composite non-adherence score consisting of three methods (self-report [i.e., The Basel Adherence Scale for Assessment of Immunossupressives-BAASIS], collateral report, and immunosuppressive blood levels. Multilevel correlations of non-adherence were assessed (macro, meso, micro and patient level. Univariate and multivariate logistic regression was applied to assess the correlates of non-adherence.Our sample consisted primarily of male (65%, Caucasians (72% with a mean age of 45.0 ± 13.5 years old, who received grafts from a living donor (89%, with a mean time after transplantation of 72.3 ± 44.4 months. Prevalence of non-adherence was 51%. Family income higher than five reference wages (21.6 vs. 4%; OR 6.46 [1.35-30.89], p = 0.009; patient level, and having access to private health insurance (35.3% vs. 18.4%; OR 2.42 [0.96-6.10], p = 0.04; meso level were associated with non-adherence in univariate analysis. Only the higher family income variable was retained in the multiple logistic regression model (OR 5.0; IC: 1.01-25.14; p = 0.04.Higher family income was the only factor that was associated with immunosuppressive non-adherence. In Brazil, lower income recipients benefit from better access to care and coverage of health care costs after transplantation. This is supposed to result in a better immunosuppressive adherence compared to high-income patients who have experienced these benefits continuously.

  12. Multilevel Correlates of Non-Adherence in Kidney Transplant Patients Benefitting from Full Cost Coverage for Immunosuppressives: A Cross-Sectional Study.

    Science.gov (United States)

    Marsicano, Elisa Oliveira; Fernandes, Neimar Silva; Colugnati, Fernando Antônio Basile; Fernandes, Natalia Maria Silva; De Geest, Sabina; Sanders-Pinheiro, Helady

    2015-01-01

    Adherence is the result of the interaction of the macro, meso, micro, and patient level factors. The macro level includes full coverage of immunosuppressive medications as is the case in Brazil. We studied the correlates of immunosuppressive non-adherence in post kidney transplant patients in the Brazilian health care system. Using a cross-sectional design, adherence to immunosuppressives was assessed in a sample of 100 kidney transplant patients using a composite non-adherence score consisting of three methods (self-report [i.e., The Basel Adherence Scale for Assessment of Immunossupressives-BAASIS], collateral report, and immunosuppressive blood levels). Multilevel correlations of non-adherence were assessed (macro, meso, micro and patient level). Univariate and multivariate logistic regression was applied to assess the correlates of non-adherence. Our sample consisted primarily of male (65%), Caucasians (72%) with a mean age of 45.0 ± 13.5 years old, who received grafts from a living donor (89%), with a mean time after transplantation of 72.3 ± 44.4 months. Prevalence of non-adherence was 51%. Family income higher than five reference wages (21.6 vs. 4%; OR 6.46 [1.35-30.89], p = 0.009; patient level), and having access to private health insurance (35.3% vs. 18.4%; OR 2.42 [0.96-6.10], p = 0.04; meso level) were associated with non-adherence in univariate analysis. Only the higher family income variable was retained in the multiple logistic regression model (OR 5.0; IC: 1.01-25.14; p = 0.04). Higher family income was the only factor that was associated with immunosuppressive non-adherence. In Brazil, lower income recipients benefit from better access to care and coverage of health care costs after transplantation. This is supposed to result in a better immunosuppressive adherence compared to high-income patients who have experienced these benefits continuously.

  13. Non-adherence in patients on chronic hemodialysis: an international comparison study.

    Science.gov (United States)

    Kugler, Christiane; Maeding, Ilona; Russell, Cynthia L

    2011-01-01

    Adherence to diet and fluid restrictions by adults on hemodialysis treatment is challenging. This study compared non-adherence (NA) to diet and fluid restrictions between adult US and German hemodialysis patients, and assessed potential predictors for NA. A cross-sectional multicenter comparative study of 456 adult hemodialysis patients was conducted in 12 outpatient-based hemodialysis centers in the United States and Germany. NA was based on self-report using the Dialysis Diet and Fluid Non-adherence Questionnaire (DDFQ). Laboratory marker, interdialytic weight gain (IDWG) and dialysis adequacy (Kt/V) information were obtained from medical records. Mean time on dialysis was 50 months (range 3-336); mean age was 62 years (range 19-91), with the majority of patients (89.7%) being white. Self-reported frequency of NA to diet was 80.4% and to fluid 75.3% in the total sample. The degree of NA to diet and fluid differed significantly, with the US patients (68.1% vs. 61.1%) reporting less NA when compared with German (81.6% vs. 79.0%) patients (phemodialysis patients. Our findings suggest that patient, condition-related, socioeconomic and health care system-related factors may contribute to NA to diet and fluid restrictions.

  14. All-phosphorus flexible devices with non-collinear electrodes: a first principles study.

    Science.gov (United States)

    Li, Junjun; Ruan, Lufeng; Wu, Zewen; Zhang, Guiling; Wang, Yin

    2018-03-07

    With the continuous expansion of the family of two-dimensional (2D) materials, flexible electronics based on 2D materials have quickly emerged. Theoretically, predicting the transport properties of the flexible devices made up of 2D materials using first principles is of great importance. Using density functional theory combined with the non-equilibrium Green's function formalism, we calculated the transport properties of all-phosphorus flexible devices with non-collinear electrodes, and the results predicted that the device with compressed metallic phosphorene electrodes sandwiching a P-type semiconducting phosphorene shows a better and robust conducting behavior against the bending of the semiconducting region when the angle between the two electrodes is less than 45°, which indicates that this system is very promising for flexible electronics. The calculation of a quantum transport system with non-collinear electrodes demonstrated in this work will provide more interesting information on mesoscopic material systems and related devices.

  15. Nanoscale contacts to organic molecules based on layered semiconductor substrates

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, Sebastian

    2009-06-15

    This work reports on the integration of organic molecules as nanoelectronic device units on semiconductor substrates. Two novel preparation methods for sub-10-nm separated metal electrodes are presented using current microelectronics process technology. The first method utilises AlGaAs/GaAs heterostructures grown by molecular beam epitaxy (MBE) as mold to create planar metal electrodes employing a newly developed, high resolution nanotransfer printing (nTP) process. The second method uses commercially available Silicon-on-Insulator (SOI) substrates as base material for the fabrication of nanogap electrode devices. This sandwich-like material stack consists of a silicon substrate, a thin silicon oxide layer, and a capping silicon layer on top. Electronic transport measurements verified their excellent electrical properties at liquid helium temperatures. Specifically tailored nanogap devices featured an electrode insulation in the GW range even up to room temperature as well as within aqueous electrolyte solution. Finally, the well defined layer architecture facilitated the fabrication of electrodes with gap separations below-10-nm to be directly bridged by molecules. Approximately 12-nm-long conjugated molecules with extended -electron system were assembled onto the devices from solution. A large conductance gap was observed with a steep increase in current at a bias voltage of V{sub T}{approx}{+-}1.5 V. Theoretical calculations based on density functional theory and non-equilibrium Green's function formalism confirmed the measured non-linear IV-characteristics qualitatively and lead to the conclusion that the conductance gap mainly originates from the oxygen containing linker. Temperature dependent investigations of the conductance indicated a hopping charge transport mechanism through the central part of the molecule for bias voltages near but below V{sub T}. (orig.)

  16. Polypyrrole Coated Cellulosic Substrate Modified by Copper Oxide as Electrode for Nitrate Electroreduction

    Science.gov (United States)

    Hamam, A.; Oukil, D.; Dib, A.; Hammache, H.; Makhloufi, L.; Saidani, B.

    2015-08-01

    The aim of this work is to synthesize polypyrrole (PPy) films on nonconducting cellulosic substrate and modified by copper oxide particles for use in the nitrate electroreduction process. Firstly, the chemical polymerization of polypyrrole onto cellulosic substrate is conducted by using FeCl3 as an oxidant and pyrrole as monomer. The thickness and topography of the different PPy films obtained were estimated using a profilometer apparatus. The electrochemical reactivity of the obtained electrodes was tested by voltamperometry technique and electrochemical impedance spectroscopy. Secondly, the modification of the PPy film surface by incorporation of copper oxide particles is conducted by applying a galvanostatic procedure from a CuCl2 solution. The SEM, EDX and XRD analysis showed the presence of CuO particles in the polymer films with dimensions less than 50 nm. From cyclic voltamperometry experiments, the composite activity for the nitrate electroreduction reaction was evaluated and the peak of nitrate reduction is found to vary linearly with initial nitrate concentration.

  17. Perceived need to take medication is associated with medication non-adherence in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Zwikker HE

    2014-11-01

    Full Text Available Hanneke E Zwikker,1,2 Sandra van Dulmen,3–5 Alfons A den Broeder,1,2 Bart J van den Bemt,1,2,6 Cornelia H van den Ende1,2 1Department of Rheumatology, 2Department of Pharmacy, Sint Maartenskliniek, Nijmegen, the Netherlands; 3Department of Primary and Community Care, Radboud University Medical Centre, Nijmegen, the Netherlands; 4NIVEL (Netherlands Institute for Health Services Research, Utrecht, the Netherlands; 5Department of Health Science, Buskerud and Vestfold University College, Drammen, Norway; 6Department of Pharmacy, Radboud University Medical Centre, Nijmegen, the Netherlands Background: This is the first cross-sectional study that aims to examine associations between beliefs about medication and non-adherence in patients with rheumatoid arthritis (RA using disease-modifying antirheumatic drugs, taking potential psychological confounders into account.Methods: Eligible patients (diagnosed with RA for ≥1 year or ≥18 years, using greater than or equal to one disease-modifying antirheumatic drug were included by their rheumatologist during regular outpatient visits between September 2009 and September 2010. Included patients received questionnaires. The Beliefs about Medicines Questionnaire was used to measure the perceived need to take medication (necessity beliefs, the concerns about taking medication (concern beliefs, general medication beliefs, and attitudes toward taking medication. Medication non-adherence (no/yes was measured using the Compliance Questionnaire Rheumatology (CQR. Associations between beliefs and non-adherence, and the influence of demographical, clinical, and psychological factors (symptoms of anxiety/depression, illness cognitions, self-efficacy were assessed using logistic regression.Results: A total of 580 of the 820 eligible patients willing to participate were included in the analyses (68% female, mean age 63 years, 30% non-adherent to their medication. Weaker necessity beliefs (OR [odds ratio]: 0.8, 95% CI

  18. The Adherence Estimator: a brief, proximal screener for patient propensity to adhere to prescription medications for chronic disease.

    Science.gov (United States)

    McHorney, Colleen A

    2009-01-01

    To conceptualize, develop, and provide preliminary psychometric evidence for the Adherence Estimator--a brief, three-item proximal screener for the likelihood of non-adherence to prescription medications (medication non-fulfillment and non-persistence) for chronic disease. Qualitative focus groups with 140 healthcare consumers and two internet-based surveys of adults with chronic disease, comprising a total of 1772 respondents, who were self-reported medication adherers, non-persisters, and non-fulfillers. Psychometric tests were performed on over 150 items assessing 14 patient beliefs and skills hypothesized to be related to medication non-adherence along a proximal-distal continuum. Psychometric tests included, but were not limited to, known-groups discriminant validity at the scale and item level. The psychometric analyses sought to identify: (1) the specific multi-item scales that best differentiated self-reported adherers from self-reported non-adherers (non-fulfillers and non-persisters) and, (2) the single best item within each prioritized multi-item scale that best differentiated self-reported adherers from self-reported non-adherers (non-fulfillers and non-persisters). The two rounds of psychometric testing identified and cross-validated three proximal drivers of self-reported adherence: perceived concerns about medications, perceived need for medications, and perceived affordability of medications. One item from each domain was selected to include in the Adherence Estimator using a synthesis of psychometric results gleaned from classical and modern psychometric test theory. By simple summation of the weights assigned to the category responses of the three items, a total score is obtained that is immediately interpretable and completely transparent. Patients can be placed into one of three segments based on the total score--low, medium, and high risk for non-adherence. Sensitivity was 88%--of the non-adherers, 88% would be accurately classified as medium

  19. Fabrication of Nickel/nanodiamond/boron-doped diamond electrode for non-enzymatic glucose biosensor

    International Nuclear Information System (INIS)

    Dai, Wei; Li, Mingji; Gao, Sumei; Li, Hongji; Li, Cuiping; Xu, Sheng; Wu, Xiaoguo; Yang, Baohe

    2016-01-01

    Highlights: • Nanodiamonds (NDs) were electrophoretically deposited on the BDD film. • The NDs significantly extended the potential window. • Ni/NDs/BDD electrode was prepared by electrodeposition. • The electrode shows good catalytic activity for glucose oxidation. - Abstract: A stable and sensitive non-enzymatic glucose sensor was prepared by modifying a boron-doped diamond (BDD) electrode with nickel (Ni) nanosheets and nanodiamonds (NDs). The NDs were electrophoretically deposited on the BDD surface, and acted as nucleation sites for the subsequent electrodeposition of Ni. The morphology and composition of the modified BDD electrodes were characterized by field-emission scanning electron microscopy and energy-dispersive X-ray spectroscopy, respectively. The Ni nanosheet-ND modified BDD electrode exhibited good current response towards the non-enzymatic oxidation of glucose in alkaline media. The NDs significantly extended the potential window. The response to glucose was linear over the 0.2–1055.4-μM range. The limit of detection was 0.05 μM, at a signal-to-noise ratio of 3. The Ni nanosheet-ND/BDD electrode exhibited good selectivity, reproducibility and stability. Its electrochemical performance, low cost and simple preparation make it a promising non-enzymatic glucose sensor.

  20. Dispensing and determinants of non-adherence to treatment for non complicated malaria caused by Plasmodium vivax and Plasmodium falciparum in high-risk municipalities in the Brazilian Amazon.

    Science.gov (United States)

    Osorio-de-Castro, Claudia G S; Suárez-Mutis, Martha C; Miranda, Elaine S; Luz, Tatiana C B

    2015-11-26

    In Brazil, 99.7 % of malaria cases occur in the Amazon region. Although the number of cases is decreasing, the country accounted for almost 60 % of cases in the Americas Region, in 2013. Novel approaches for malaria treatment open the possibility of eliminating the disease, but suboptimal dispensing and lack of adherence influence treatment outcomes. The aim of this paper is to show the results on dispensing practices, non-adherence and determinants of non-adherence to treatment of non-complicated malaria. The study was conducted in six high-risk municipalities with Plasmodium vivax and Plasmodium falciparum transmission in the Brazilian Amazon and based on the theoretical framework of the Mafalda Project, which included investigation of dispensing and adherence. The World Health Organization Rapid Evaluation Method has been used to estimate sample size. Individuals over 15 years of age with malaria were approached at health facilities and invited to participate through informed consent. Data was collected in chart review forms focusing on diagnosis, Plasmodium type, prescribing, and dispensing (kind, quantity, labelling and procedures). Follow-up household interviews complemented data collection at health facility. Non-adherence was measured during the implementation phase, by self-reports and pill-counts. Analysis was descriptive and statistical tests were carried out. Determinants of non-adherence and quality of dispensing were assessed according to the literature. The study involved 165 patients. Dispensing was done according to the national guidelines. Labelling was adequate for P. vivax but inadequate for P. falciparum medicines. Non-adherent patients were 12.1 % according to self-reports and 21.8 % according to pill-counts. Results point to greater non-adherence among all P. falciparum patients and among malaria non-naîve patients. More patients informed understanding adverse effects than 'how to use' anti-malarials. Non-adherent patients were mostly those

  1. Investigation of bacterial adherence to a non-precious alloy with radiolabeling method

    International Nuclear Information System (INIS)

    Sonugelen, M.; Iyiyapici Destan, U.; Oeztuerk, B.; Yurt Lambrecht, F.

    2006-01-01

    The objective of this study was to investigate the bacterial adherence to a non-precious alloy with radiolabeling method. S. mutans, E. coliand C. albicanswere labeled with 99m Tc by using stannous chloride and their radiolabeling yields were calculated. After the labeling procedure, metal disks (3 mm x 10 mm) were treated with microorganisms. The amount of labeled microorganisms adhered on metal surfaces was determined by activity measurements. The labeling yields for S. mutans, E. coliand C. albicanswere 69.95 ± 7.58%, 78.84 ± 0.44% and 79.71 ± 10.17%, respectively. The mean values for adherence for S. mutans, E. coliand C. albicans on metal samples were 7.02 ± 2.18%, 0.96 ± 0.49% and 8.80 ± 8.24%, respectively. The radiolabeling method could be considered as safe and precise for determining the adherence of microorganisms. (author)

  2. The effect of requesting a reason for non-adherence to a guideline in a long running automated reminder system for PONV prophylaxis.

    Science.gov (United States)

    Kooij, Fabian O; Klok, Toni; Preckel, Benedikt; Hollmann, Markus W; Kal, Jasper E

    2017-03-29

    Automated reminders are employed frequently to improve guideline adherence, but limitations of automated reminders are becoming more apparent. We studied the reasons for non-adherence in the setting of automated reminders to test the hypothesis that a separate request for a reason in itself may further improve guideline adherence. In a previously implemented automated reminder system on prophylaxis for postoperative nausea and vomiting (PONV), we included additional automated reminders requesting a reason for non-adherence. We recorded these reasons in the pre-operative screening clinic, the OR and the PACU. We compared adherence to our PONV guideline in two study groups with a historical control group. Guideline adherence on prescribing and administering PONV prophylaxis (dexamethasone and granisetron) all improved compared to the historical control group (89 vs. 82% (preason for not prescribing PONV prophylaxis was disagreement with the risk estimate by the decision support system. In the OR/PACU, the main reasons for not administering PONV prophylaxis were: 'unintended non-adherence' and 'failure to document'. In this study requesting a reason for non-adherence is associated with improved guideline adherence. The effect seems to depend on the underlying reason for non-adherence. It also illustrates the importance of human factors principles in the design of decision support. Some reasons for non-adherence may not be influenced by automated reminders.

  3. Spatial atomic layer deposition on flexible porous substrates: ZnO on anodic aluminum oxide films and Al2O3 on Li ion battery electrodes

    International Nuclear Information System (INIS)

    Sharma, Kashish; Routkevitch, Dmitri; Varaksa, Natalia; George, Steven M.

    2016-01-01

    Spatial atomic layer deposition (S-ALD) was examined on flexible porous substrates utilizing a rotating cylinder reactor to perform the S-ALD. S-ALD was first explored on flexible polyethylene terephthalate polymer substrates to obtain S-ALD growth rates on flat surfaces. ZnO ALD with diethylzinc and ozone as the reactants at 50 °C was the model S-ALD system. ZnO S-ALD was then performed on nanoporous flexible anodic aluminum oxide (AAO) films. ZnO S-ALD in porous substrates depends on the pore diameter, pore aspect ratio, and reactant exposure time that define the gas transport. To evaluate these parameters, the Zn coverage profiles in the pores of the AAO films were measured using energy dispersive spectroscopy (EDS). EDS measurements were conducted for different reaction conditions and AAO pore geometries. Substrate speeds and reactant pulse durations were defined by rotating cylinder rates of 10, 100, and 200 revolutions per minute (RPM). AAO pore diameters of 10, 25, 50, and 100 nm were utilized with a pore length of 25 μm. Uniform Zn coverage profiles were obtained at 10 RPM and pore diameters of 100 nm. The Zn coverage was less uniform at higher RPM values and smaller pore diameters. These results indicate that S-ALD into porous substrates is feasible under certain reaction conditions. S-ALD was then performed on porous Li ion battery electrodes to test S-ALD on a technologically important porous substrate. Li 0.20 Mn 0.54 Ni 0.13 Co 0.13 O 2 electrodes on flexible metal foil were coated with Al 2 O 3 using 2–5 Al 2 O 3 ALD cycles. The Al 2 O 3 ALD was performed in the S-ALD reactor at a rotating cylinder rate of 10 RPM using trimethylaluminum and ozone as the reactants at 50 °C. The capacity of the electrodes was then tested versus number of charge–discharge cycles. These measurements revealed that the Al 2 O 3 S-ALD coating on the electrodes enhanced the capacity stability. This S-ALD process could be extended to roll-to-roll operation for

  4. Aerosol jet printed silver nanowire transparent electrode for flexible electronic application

    Science.gov (United States)

    Tu, Li; Yuan, Sijian; Zhang, Huotian; Wang, Pengfei; Cui, Xiaolei; Wang, Jiao; Zhan, Yi-Qiang; Zheng, Li-Rong

    2018-05-01

    Aerosol jet printing technology enables fine feature deposition of electronic materials onto low-temperature, non-planar substrates without masks. In this work, silver nanowires (AgNWs) are proposed to be printed into transparent flexible electrodes using a Maskless Mesoscale Material Deposition Aerosol Jet® printing system on a glass substrate. The influence of the most significant process parameters, including printing cycles, printing speed, and nozzle size, on the performance of AgNW electrodes was systematically studied. The morphologies of printed patterns were characterized by scanning electron microscopy, and the transmittance was evaluated using an ultraviolet-visible spectrophotometer. Under optimum conditions, high transparent AgNW electrodes with a sheet resistance of 57.68 Ω/sq and a linewidth of 50.9 μm were obtained, which is an important step towards a higher performance goal for flexible electronic applications.

  5. Organic against inorganic electrodes grown onto polymer substrates for flexible organic electronics applications

    International Nuclear Information System (INIS)

    Logothetidis, S.; Laskarakis, A.

    2009-01-01

    One of the most challenging topics in the area of organic electronic devices is the growth of transparent electrodes onto flexible polymeric substrates that will be characterized by enhanced conductivity in combination with high optical transparency. An essential aspect for these materials is their synthesis and/or microstructure which define the transparency, the stability and the interfacial chemistry which in turn determine the performance and stability of the organic electronic devices, such as organic light emitting diodes, organic photovoltaics, etc. In this work, we will discuss the latest advances in the growth of organic (e.g. PEDOT:PSS) and inorganic (e.g. zinc oxide-ZnO, indium tin oxide-ITO) conductive materials and their deposition onto flexible polymeric substrates. We will compare the optical, structural, nano-mechanical and nano-topographical properties of the inorganic and organic materials and we investigate the effect of their structure on their properties and functionality. In the case of the organic conductive materials, we will discuss the effects of PEDOT:PSS weight ratios and the various spin speeds on their optical and electrical properties. Furthermore, in the case of ZnO the growth mechanisms, interface phenomena, crystallinity and optical properties of ZnO thin films grown onto polymer and hybrid (inorganic-organic) flexible substrates will be also discussed.

  6. Risk factors for non-adherence and loss to follow-up in a three-year clinical trial in Botswana.

    Directory of Open Access Journals (Sweden)

    Deborah A Gust

    Full Text Available BACKGROUND: Participant non-adherence and loss to follow-up can compromise the validity of clinical trial results. An assessment of these issues was made in a 3-year tuberculosis prevention trial among HIV-infected adults in Botswana. METHODS AND FINDINGS: Between 11/2004-07/2006, 1995 participants were enrolled at eight public health clinics. They returned monthly to receive bottles of medication and were expected to take daily tablets of isoniazid or placebo for three years. Non-adherence was defined as refusing tablet ingestion but agreeing to quarterly physical examinations. Loss to follow-up was defined as not having returned for appointments in ≥60 days. Between 10/2008-04/2009, survey interviews were conducted with 83 participants identified as lost to follow-up and 127 identified as non-adherent. As a comparison, 252 randomly selected adherent participants were also surveyed. Multivariate logistic regression analysis was used to identify associations with selected risk factors. Men had higher odds of being non-adherent (adjusted odds ratio (AOR, 2.24; 95% confidence interval [95%CI] 1.24-4.04 and lost to follow-up (AOR 3.08; 95%CI 1.50-6.33. Non-adherent participants had higher odds of reporting difficulties taking the regimen or not knowing if they had difficulties (AOR 3.40; 95%CI 1.75-6.60 and lower odds associated with each year of age (AOR 0.95; 95%CI 0.91-0.98, but other variables such as employment, distance from clinic, alcohol use, and understanding study requirements were not significantly different than controls. Among participants who were non-adherent or lost to follow-up, 40/210 (19.0% reported that they stopped the medication because of work commitments and 33/210 (15.7% said they thought they had completed the study. CONCLUSIONS: Men had higher odds of non-adherence and loss to follow-up than women. Potential interventions that might improve adherence in trial participants may include:targeting health education for men

  7. Risk factors for non-adherence and loss to follow-up in a three-year clinical trial in Botswana.

    Science.gov (United States)

    Gust, Deborah A; Mosimaneotsile, Barudi; Mathebula, Unami; Chingapane, Balladiah; Gaul, Zaneta; Pals, Sherri L; Samandari, Taraz

    2011-04-25

    Participant non-adherence and loss to follow-up can compromise the validity of clinical trial results. An assessment of these issues was made in a 3-year tuberculosis prevention trial among HIV-infected adults in Botswana. Between 11/2004-07/2006, 1995 participants were enrolled at eight public health clinics. They returned monthly to receive bottles of medication and were expected to take daily tablets of isoniazid or placebo for three years. Non-adherence was defined as refusing tablet ingestion but agreeing to quarterly physical examinations. Loss to follow-up was defined as not having returned for appointments in ≥60 days. Between 10/2008-04/2009, survey interviews were conducted with 83 participants identified as lost to follow-up and 127 identified as non-adherent. As a comparison, 252 randomly selected adherent participants were also surveyed. Multivariate logistic regression analysis was used to identify associations with selected risk factors. Men had higher odds of being non-adherent (adjusted odds ratio (AOR), 2.24; 95% confidence interval [95%CI] 1.24-4.04) and lost to follow-up (AOR 3.08; 95%CI 1.50-6.33). Non-adherent participants had higher odds of reporting difficulties taking the regimen or not knowing if they had difficulties (AOR 3.40; 95%CI 1.75-6.60) and lower odds associated with each year of age (AOR 0.95; 95%CI 0.91-0.98), but other variables such as employment, distance from clinic, alcohol use, and understanding study requirements were not significantly different than controls. Among participants who were non-adherent or lost to follow-up, 40/210 (19.0%) reported that they stopped the medication because of work commitments and 33/210 (15.7%) said they thought they had completed the study. Men had higher odds of non-adherence and loss to follow-up than women. Potential interventions that might improve adherence in trial participants may include:targeting health education for men, reducing barriers, clarifying study expectations, educating

  8. PLZT capacitor on glass substrate

    Science.gov (United States)

    Fairchild, M. Ray; Taylor, Ralph S.; Berlin, Carl W.; Wong, Celine W. K.; Ma, Beihai; Balachandran, Uthamalingam

    2016-01-05

    A lead-lanthanum-zirconium-titanate (PLZT) capacitor on a substrate formed of glass. The first metallization layer is deposited on a top side of the substrate to form a first electrode. The dielectric layer of PLZT is deposited over the first metallization layer. The second metallization layer deposited over the dielectric layer to form a second electrode. The glass substrate is advantageous as glass is compatible with an annealing process used to form the capacitor.

  9. Causes of non-adherence to therapeutic guidelines in severe community-acquired pneumonia

    Science.gov (United States)

    Gattarello, Simone; Ramírez, Sergio; Almarales, José Rafael; Borgatta, Bárbara; Lagunes, Leonel; Encina, Belén; Rello, Jordi

    2015-01-01

    Objective To assess the adherence to Infectious Disease Society of America/American Thoracic Society guidelines and the causes of lack of adherence during empirical antibiotic prescription in severe pneumonia in Latin America. Methods A clinical questionnaire was submitted to 36 physicians from Latin America; they were asked to indicate the empirical treatment in two fictitious cases of severe respiratory infection: community-acquired pneumonia and nosocomial pneumonia. Results In the case of communityacquired pneumonia, 11 prescriptions of 36 (30.6%) were compliant with international guidelines. The causes for non-compliant treatment were monotherapy (16.0%), the unnecessary prescription of broad-spectrum antibiotics (40.0%) and the use of non-recommended antibiotics (44.0%). In the case of nosocomial pneumonia, the rate of adherence to the Infectious Disease Society of America/American Thoracic Society guidelines was 2.8% (1 patient of 36). The reasons for lack of compliance were monotherapy (14.3%) and a lack of dual antibiotic coverage against Pseudomonas aeruginosa (85.7%). If monotherapy with an antipseudomonal antibiotic was considered adequate, the antibiotic treatment would be adequate in 100% of the total prescriptions. Conclusion The compliance rate with the Infectious Disease Society of America/American Thoracic Society guidelines in the community-acquired pneumonia scenario was 30.6%; the most frequent cause of lack of compliance was the indication of monotherapy. In the case of nosocomial pneumonia, the compliance rate with the guidelines was 2.8%, and the most important cause of non-adherence was lack of combined antipseudomonal therapy. If the use of monotherapy with an antipseudomonal antibiotic was considered the correct option, the treatment would be adequate in 100% of the prescriptions. PMID:25909312

  10. Machine learning classification of medication adherence in patients with movement disorders using non-wearable sensors.

    Science.gov (United States)

    Tucker, Conrad S; Behoora, Ishan; Nembhard, Harriet Black; Lewis, Mechelle; Sterling, Nicholas W; Huang, Xuemei

    2015-11-01

    Medication non-adherence is a major concern in the healthcare industry and has led to increases in health risks and medical costs. For many neurological diseases, adherence to medication regimens can be assessed by observing movement patterns. However, physician observations are typically assessed based on visual inspection of movement and are limited to clinical testing procedures. Consequently, medication adherence is difficult to measure when patients are away from the clinical setting. The authors propose a data mining driven methodology that uses low cost, non-wearable multimodal sensors to model and predict patients' adherence to medication protocols, based on variations in their gait. The authors conduct a study involving Parkinson's disease patients that are "on" and "off" their medication in order to determine the statistical validity of the methodology. The data acquired can then be used to quantify patients' adherence while away from the clinic. Accordingly, this data-driven system may allow for early warnings regarding patient safety. Using whole-body movement data readings from the patients, the authors were able to discriminate between PD patients on and off medication, with accuracies greater than 97% for some patients using an individually customized model and accuracies of 78% for a generalized model containing multiple patient gait data. The proposed methodology and study demonstrate the potential and effectiveness of using low cost, non-wearable hardware and data mining models to monitor medication adherence outside of the traditional healthcare facility. These innovations may allow for cost effective, remote monitoring of treatment of neurological diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Prevalence and correlates of medication non-adherence among kidney transplant recipients more than 6 months post-transplant: a cross-sectional study.

    Science.gov (United States)

    Weng, Francis L; Chandwani, Sheenu; Kurtyka, Karen M; Zacker, Christopher; Chisholm-Burns, Marie A; Demissie, Kitaw

    2013-12-01

    Among kidney transplant recipients, non-adherence with immunosuppressive medications frequently precedes allograft loss. We sought to determine the prevalence and correlates of medication non-adherence among kidney transplant recipients. We performed a single-center, cross-sectional study of kidney transplant recipients who were at least 6 months post-transplant. We measured self-reported adherence using the Immunosuppressive Therapy Adherence Scale (ITAS, which is scored from 0 to 12, where higher scores indicate increased adherence) and barriers to adherence using the Immunosuppressive Therapy Barriers Scale (ITBS). We also used validated scales to measure perceived stress, health literacy, anxiety, depression, and interpersonal support. The 252 patients included in the study were 59.9% male, 27.0% Black, and at a median of 2.9 years post-transplant (interquartile range [IQR] 1.4-5.8). On the ITAS, 59.1% scored a perfect 12, 26.6% scored 10-11, and 14.3% scored 0-9. In univariate models, non-adherence (defined as ITAS score ≤9) was significantly associated with increased scores on scales for perceived stress (OR 1.12, 95% CI 1.01-1.25) and depression (OR 1.14, 95% CI 1.02-1.28), and with more self-reported barriers to adherence on the ITBS (OR 1.15, 95% CI 1.08-1.22). After adjusting for sociodemographic factors, stress and depression were not associated with non-adherence. Higher scores on the ITBS (corresponding to more self-described barriers to adherence) were associated with lower scores on the ITAS (P adherence. Among prevalent kidney transplant recipients, a minority is non-adherent. Practical barriers to adherence may serve as promising targets for future interventions.

  12. Alcohol use and non-adherence to antiretroviral therapy in HIV-infected patients in West Africa

    Science.gov (United States)

    Antoine, Jaquet; Ekouevi Didier, K; Jules, Bashi; Maiga, Aboubakrine; Eugène, Messou; Moussa, Maiga; Alassane, Traore Hamar; Djimon, Zannou Marcel; Calixte, Guehi; Olivier, Ba-Gomis Franck; Albert, Minga; Gérard, Allou; Paul, Eholie Serge; Emmanuel, Bissagnene; Sasco Annie, J; Francois, Dabis

    2015-01-01

    AIM To investigate the association between alcohol use and adherence to Highly Active Antiretroviral Treatment (HAART) among HIV-infected patients in sub-Saharan Africa. DESIGN and MEASURES Cross sectional survey conducted in eight adult HIV treatment centers from Benin, Côte d’Ivoire and Mali. During a four-week period, health workers administered the Alcohol Use Disorders Identification Test to HAART-treated patients and assessed treatment adherence using the AIDS Clinical Trials Group follow-up questionnaire. RESULTS A total of 2920 patients were enrolled with a median age of 38 years (IQR 32–45 years) and a median duration on HAART of 3 years (IQR 1–4 years). Overall, 91.8% of patients were identified as adherent to HAART. Non-adherence was associated with current drinking (OR 1.4; 95% CI 1.1–2.0), hazardous drinking (OR 4.7; 95% CI 2.6–8.6) and was inversely associated with a history of counseling on adherence (OR 0.7; 95% CI 0.5–0.9). CONCLUSION Alcohol consumption and hazardous drinking is associated with non-adherence to HAART among HIV-infected patients from West Africa. thus providing a framework for developing and reinforcing the necessary prevention and intervention strategies. PMID:20528816

  13. Adherent diamond coatings on cemented tungsten carbide substrates with new Fe/Ni/Co binder phase

    International Nuclear Information System (INIS)

    Polini, Riccardo; Delogu, Michele; Marcheselli, Giancarlo

    2006-01-01

    WC-Co hard metals continue to gain importance for cutting, mining and chipless forming tools. Cobalt metal currently dominates the market as a binder because of its unique properties. However, the use of cobalt as a binder has several drawbacks related to its hexagonal close-packed structure and market price fluctuations. These issues pushed the development of pre-alloyed binder powders which contain less than 40 wt.% cobalt. In this paper we first report the results of extensive investigations of WC-Fe/Ni/Co hard metal sintering, surface pretreating and deposition of adherent diamond films by using an industrial hot filament chemical vapour deposition (HFCVD) reactor. In particular, CVD diamond was deposited onto WC-Fe/Ni/Co grades which exhibited the best mechanical properties. Prior to deposition, the substrates were submitted to surface roughening by Murakami's etching and to surface binder removal by aqua regia. The adhesion was evaluated by Rockwell indentation tests (20, 40, 60 and 100 kg) conducted with a Brale indenter and compared to the adhesion of diamond films grown onto Co-cemented tungsten carbide substrates, which were submitted to similar etching pretreatments and identical deposition conditions. The results showed that diamond films on medium-grained WC-6 wt.% Fe/Ni/Co substrates exhibited good adhesion levels, comparable to those obtained for HFCVD diamond on Co-cemented carbides with similar microstructure

  14. Pulsed laser deposition of transparent conductive oxide thin films on flexible substrates

    International Nuclear Information System (INIS)

    Socol, G.; Socol, M.; Stefan, N.; Axente, E.; Popescu-Pelin, G.; Craciun, D.; Duta, L.; Mihailescu, C.N.; Mihailescu, I.N.; Stanculescu, A.; Visan, D.; Sava, V.; Galca, A.C.; Luculescu, C.R.; Craciun, V.

    2012-01-01

    Highlights: ► TCO thin films were grown by PLD on PET substrate at low temperature. ► We found that the quality of TCO on PET substrate depends on the target–substrate distance. ► TCO with high transparency (>95%) and reduced electrical resistivity (∼5 × 10 −4 Ω cm) were obtained. ► Optimized TCO films deposited on PET were free of any cracks. - Abstract: The influence of target–substrate distance during pulsed laser deposition of indium zinc oxide (IZO), indium tin oxide (ITO) and aluminium-doped zinc oxide (AZO) thin films grown on polyethylene terephthalate (PET) substrates was investigated. It was found that the properties of such flexible transparent conductive oxide (TCO)/PET electrodes critically depend on this parameter. The TCO films that were deposited at distances of 6 and 8 cm exhibited an optical transmittance higher than 90% in the visible range and electrical resistivities around 5 × 10 −4 Ω cm. In addition to these excellent electrical and optical characteristics the films grown at 8 cm distance were homogenous, smooth, adherent, and without cracks or any other extended defects, being suitable for opto-electronic device applications.

  15. Pre-transplant history of mental health concerns, non-adherence, and post-transplant outcomes in kidney transplant recipients.

    Science.gov (United States)

    Gumabay, Franz Marie; Novak, Marta; Bansal, Aarushi; Mitchell, Margot; Famure, Olusegun; Kim, S Joseph; Mucsi, Istvan

    2018-02-01

    The association between pre-transplant mental health concerns and non-adherence and post-transplant outcomes after kidney transplantation is not fully established. We examined the relationship between a pre-transplant history of mental health concerns and non-adherence and post-transplant outcomes among kidney transplant recipients. In this retrospective single center cohort study of adult kidney transplant recipients (n=955) the associations between the history of mental health concerns or non-adherence and the time from kidney transplant to biopsy proven acute rejection; death-censored graft failure and total graft failure were examined using Cox proportional hazards models. Mean (SD) age was 51 (13) years, 61% were male and 27% had a history of diabetes. Twenty-two and 11% of patients had mental health concerns and non-adherence, respectively. Fifteen percent of the patients had acute rejection, 5.6% had death-censored graft failure and 13.0% had total graft failure. The history of mental health concerns was not associated with acute rejection, death-censored graft failure or total graft failure. Patients with versus without a history of non-adherence tended to have higher cumulative incidence of acute rejection (23.3% [95% CI: 16.1, 33.2] vs. 13.6% [95% CI: 11.4, 16.2]) and death-censored graft failure (15.0% [95% CI: 6.9, 30.8] vs. 6.4% [95% CI: 4.7, 8.7]) (log rank p=0.052 and p=0.086, respectively). These trends were not significant after multivariable adjustment. In summary, a history of pre-transplant mental health concerns or non-adherence is not associated with adverse outcomes in patients who completed transplant workup and received a kidney transplant. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Multilevel Correlates of Non-Adherence in Kidney Transplant Patients Benefitting from Full Cost Coverage for Immunosuppressives: A Cross-Sectional Study

    OpenAIRE

    Marsicano, Elisa Oliveira; Fernandes, Neimar Silva; Colugnati, Fernando Ant?nio Basile; Fernandes, Natalia Maria Silva; De Geest, Sabina; Sanders-Pinheiro, Helady

    2015-01-01

    Background Adherence is the result of the interaction of the macro, meso, micro, and patient level factors. The macro level includes full coverage of immunosuppressive medications as is the case in Brazil. We studied the correlates of immunosuppressive non-adherence in post kidney transplant patients in the Brazilian health care system. Methods Using a cross-sectional design, adherence to immunosuppressives was assessed in a sample of 100 kidney transplant patients using a composite non-adher...

  17. Performance of Multi Walled Carbon Nanotubes Grown on Conductive Substrates as Supercapacitors Electrodes using Organic and Ionic liquid electrolytes

    Science.gov (United States)

    Winchester, Andrew; Ghosh, Sujoy; Turner, Ben; Zhang, X. F.; Talapatra, Saikat

    2012-02-01

    In this work we will present the use of Multi Walled Carbon Nanotubes (MWNT) directly grown on inconel substrates via chemical vapor deposition, as electrode materials for electrochemical double layer capacitors (EDLC). The performance of the MWNT EDLC electrodes were investigated using two electrolytes, an organic electrolyte, tetraethylammonium tetrafluoroborate in propylene carbonate (Et4NBF4 in PC), and a room temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6). Cyclic voltammetry, galvanostatic charge-discharge, and electrochemical impedance spectroscopy measurements to obtain values for the capacitance and internal resistance of these devices will be presented and compared.

  18. Carbon nanotube network thin-film transistors on flexible/stretchable substrates

    Science.gov (United States)

    Takei, Kuniharu; Takahashi, Toshitake; Javey, Ali

    2016-03-29

    This disclosure provides systems, methods, and apparatus for flexible thin-film transistors. In one aspect, a device includes a polymer substrate, a gate electrode disposed on the polymer substrate, a dielectric layer disposed on the gate electrode and on exposed portions of the polymer substrate, a carbon nanotube network disposed on the dielectric layer, and a source electrode and a drain electrode disposed on the carbon nanotube network.

  19. Machining of insulation ZrO2 ceramics by EDM using graphite electrode

    International Nuclear Information System (INIS)

    Tani, T.; Okada, M.; Fukuzawa, Y.; Mohri, N.

    1998-01-01

    As we proposed and reported before, insulating ceramics may be made into machinable materials with electrical discharge machining method by using an assisting electrode method. The machining properties depend on the formation mechanism of carbonization layer which has electrical conductivity on the ceramics surface during discharge. A big difference in machinability occurs between oxide and non-oxide ceramics. When ZrO 2 ceramics are machined with a copper tool electrode which was used for a machining of the non-oxide ceramics Si 3 N 4 , the electrical conductive layer is not formed on the machined surface uniformly. In this paper, in order to activate a carbonization reaction on the ceramics surface during discharge, the use of a porous graphite tool electrode is described. As a result of that, carbonized reaction occurs actively on the discharge gap and the uniform carbonized layer adheres to the machined surface. The surface roughness is much improved compared with previous machining conditions. Copyright (1998) Australasian Ceramic Society

  20. Structures and electrochemical properties of pyrolytic carbon films infiltrated from gas phase into electro-conductive substrates derived from wood

    International Nuclear Information System (INIS)

    Ohzawa, Yoshimi; Mitani, Masami; Li, Jianling; Nakajima, Tsuyoshi

    2004-01-01

    Using the pressure-pulsed chemical vapor infiltration technique, pyrolytic carbon (pyrocarbon) films were deposited into two sorts of conductive porous substrates, that is, the carbonized wood (A) and the TiN-coated wood (B). Structures and electrochemical properties were investigated as the negative electrodes of lithium-ion secondary battery. The electrodes had the three-dimensionally continuous current paths in the pyrocarbon-based anodes without the organic binders and the additional conductive fillers. The pyrocarbon films adhered tightly to the carbonized wood or TiN as current collector. These macro-structures of electrodes were effective in improving the high rate property. The sort of substrates affected the nano-structure of pyrocarbon. The pyrocarbon in sample (A) had the relatively high crystallinity, whereas the pyrocarbon in sample (B) was disordered. The capacity of pyrocarbon in sample (B) was higher than that of sample (A), reflecting the disordered microstructure of pyrocarbon film (B). However, sample (A) showed higher Coulombic efficiency at first cycle (i.e. 87%) than that of sample (B), which would result from the high crystallinity, laminar microstructure and low surface area of pyrocarbon in sample (A)

  1. An electrochemical study on the positive electrode side of the zinc–cerium hybrid redox flow battery

    International Nuclear Information System (INIS)

    Nikiforidis, Georgios; Berlouis, Léonard; Hall, David; Hodgson, David

    2014-01-01

    Highlights: •Elevated temperatures favoured the Ce 3+/4+ reaction on the Pt, Pt–Ir and carbon substrates. •j o increased with temperature over the range 25 °C to 60 °C for all substrates. •Non-porous carbon substrates showed higher reversibility on the Ce 3+/4+ reaction. •Surface degradation of the carbon electrodes occurred due to the high positive potentials. •The Pt–Ir coatings gave the largest j o at 60 °C and appear best suited for use as the positive electrode in the Zn–Ce RFB. -- Abstract: In this study, the electrochemical behaviour of the Ce 3+/4+ redox couple in methanesulfonic acid medium on various electrode substrates was investigated as a function of temperature. Carbon composite electrodes as well as platinum and platinum iridium coated electrodes were studied for their suitability in carrying out the Ce 3+/4+ redox reaction. Cyclic voltammetry in 0.8 mol dm −3 cerium and 4.5 mol dm −3 methanesulfonic acid solution showed that elevated temperatures favoured the Ce 3+ /Ce 4+ reaction on the various platinum and platinum–iridium coated substrates as well as on carbon composite surfaces. The latter electrodes showed better kinetics than the metal coatings but deteriorated badly under the high positive potentials required for the cerium reaction. The exchange current density (j o ), obtained through Tafel extrapolation, polarisation resistance and electrochemical impedance spectroscopy measurements, increased with temperature over the range 25 °C to 60 °C. The Pt–Ir coatings gave the largest j o at 60 °C and appear best suited for use as the positive electrode in the Zn–Ce redox flow battery

  2. The Effect of Psychosocial Factors and Patients' Perception of Tuberculosis Treatment Non-Adherence in Addis Ababa, Ethiopia.

    Science.gov (United States)

    Tola, Habteyes Hailu; Garmaroudi, Gholamreza; Shojaeizadeh, Davoud; Tol, Azar; Yekaninejad, Mir Saeed; Ejeta, Luche Tadesse; Kebede, Abebaw; Kassa, Desta

    2017-09-01

    Although there are several studies reported on factors affecting tuberculosis (TB) treatment non-adherence, there is information gap on psychosocial and patients' perceptions aspects. Therefore, this study was aimed to investigate the effect of psychosocial factors and patients' perceptions on TB treatment non-adherence in Ethiopia. A cross sectional study was conducted in Addis Ababa from May to December, 2014. Thirty one health facilities were randomly selected and 698 TB patients, who had been on treatment, were enrolled consecutively using patient registration number. Structured questionnaire was used to collect data on demographics, knowledge, psychological distress, alcohol use, tobacco smoking and six HBM domains. Treatment adherence level was the main outcome variable, and it measured using visual analog scale. Statistical Package for Social Sciences version 20 was used for data analysis. Non-adherence level within last one month prior to the study was 19.5%. After controlling for all potential confounding variables, Antiretroviral Therapy (ART) status (Adjusted Odds Ratio (AOR) = 1.79, 95% Confidence interval (CI) (1.09 -2.95)), alcohol use (AOR = 2.11, 95% CI (1.33-3.37)), economic status (AOR = 0.53, 95% CI (0.33-0.82)), perceived barriers (AOR = 1.21, 95% CI (1.10-1.47)) and psychological distress (AOR = 1.83, 95% CI (1.47-2.29)) were independently associated with TB treatment non-adherence. ART status, economic status, alcohol use, perceived barrier and psychological distress are the major areas that need to be targeted with health promotion intervention to enhance TB treatment adherence.

  3. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  4. Method for preventing micromechanical structures from adhering to another object

    Science.gov (United States)

    Smith, J.H.; Ricco, A.J.

    1998-06-16

    A method for preventing micromechanical structures from adhering to another object includes the step of immersing a micromechanical structure and its associated substrate in a chemical species that does not stick to itself. The method can be employed during the manufacture of micromechanical structures to prevent micromechanical parts from sticking or adhering to one another and their associated substrate surface. 3 figs.

  5. Catalytic mechanism of phenylacetone monooxygenases for non-native linear substrates.

    Science.gov (United States)

    Carvalho, Alexandra T P; Dourado, Daniel F A R; Skvortsov, Timofey; de Abreu, Miguel; Ferguson, Lyndsey J; Quinn, Derek J; Moody, Thomas S; Huang, Meilan

    2017-10-11

    Phenylacetone monooxygenase (PAMO) is the most stable and thermo-tolerant member of the Baeyer-Villiger monooxygenase family, and therefore it is an ideal candidate for the synthesis of industrially relevant compounds. However, its limited substrate scope has largely limited its industrial applications. In the present work, we provide, for the first time, the catalytic mechanism of PAMO for the native substrate phenylacetone as well as for a linear non-native substrate 2-octanone, using molecular dynamics simulations, quantum mechanics and quantum mechanics/molecular mechanics calculations. We provide a theoretical basis for the preference of the enzyme for the native aromatic substrate over non-native linear substrates. Our study provides fundamental atomic-level insights that can be employed in the rational engineering of PAMO for wide applications in industrial biocatalysis, in particular, in the biotransformation of long-chain aliphatic oils into potential biodiesels.

  6. Methods of etching a substrate

    International Nuclear Information System (INIS)

    Cosmo, J.J.; Gambino, R.J.; Harper, J.M.E.

    1979-01-01

    The invention relates to a method of etching a substrate. The substrate is located opposite a target electrode in a vacuum chamber, and the surface of the target electrode is bombarded with energetic particles of atomic dimensions. The target electrode is an intermetallic composition (compound, alloy or finely divided homogeneous mixture) of two metals A and B such that upon bombardment the electrode emits negative ions of metal B which have sufficient energy to produce etching of the substrate. Many target materials are exemplified. Typically the metal A has an electronegativity XA and metal B has an electronegativity XB such that Xb - Xa is greater than about 2.55 electron volts, with the exception of combinations of metals having a fractional ionicity Q less than about 0.314. The source of the energetic particles may be an ionised gas in the vacuum chamber. The apparatus and its mode of operation are described in detail. (U.K.)

  7. Methods of etching a substrate

    Energy Technology Data Exchange (ETDEWEB)

    Cosmo, J J; Gambino, R J; Harper, J M.E.

    1979-05-16

    The invention relates to a method of etching a substrate. The substrate is located opposite a target electrode in a vacuum chamber, and the surface of the target electrode is bombarded with energetic particles of atomic dimensions. The target electrode is an intermetallic composition (compound, alloy or finely divided homogeneous mixture) of two metals A and B such that upon bombardment the electrode emits negative ions of metal B which have sufficient energy to produce etching of the substrate. Many target materials are exemplified. Typically the metal A has an electronegativity XA and metal B has an electronegativity XB such that Xb - Xa is greater than about 2.55 electron volts, with the exception of combinations of metals having a fractional ionicity Q less than about 0.314. The source of the energetic particles may be an ionised gas in the vacuum chamber. The apparatus and its mode of operation are described in detail.

  8. Prevalence and correlates of medication non-adherence among kidney transplant recipients more than 6 months post-transplant: a cross-sectional study

    Science.gov (United States)

    2013-01-01

    Background Among kidney transplant recipients, non-adherence with immunosuppressive medications frequently precedes allograft loss. We sought to determine the prevalence and correlates of medication non-adherence among kidney transplant recipients. Methods We performed a single-center, cross-sectional study of kidney transplant recipients who were at least 6 months post-transplant. We measured self-reported adherence using the Immunosuppressive Therapy Adherence Scale (ITAS, which is scored from 0 to 12, where higher scores indicate increased adherence) and barriers to adherence using the Immunosuppressive Therapy Barriers Scale (ITBS). We also used validated scales to measure perceived stress, health literacy, anxiety, depression, and interpersonal support. Results The 252 patients included in the study were 59.9% male, 27.0% Black, and at a median of 2.9 years post-transplant (interquartile range [IQR] 1.4-5.8). On the ITAS, 59.1% scored a perfect 12, 26.6% scored 10–11, and 14.3% scored 0–9. In univariate models, non-adherence (defined as ITAS score ≤9) was significantly associated with increased scores on scales for perceived stress (OR 1.12, 95% CI 1.01-1.25) and depression (OR 1.14, 95% CI 1.02-1.28), and with more self-reported barriers to adherence on the ITBS (OR 1.15, 95% CI 1.08-1.22). After adjusting for sociodemographic factors, stress and depression were not associated with non-adherence. Higher scores on the ITBS (corresponding to more self-described barriers to adherence) were associated with lower scores on the ITAS (P adherence. Conclusions Among prevalent kidney transplant recipients, a minority is non-adherent. Practical barriers to adherence may serve as promising targets for future interventions. PMID:24289809

  9. Fabrication of nano-electrode arrays of free-standing carbon nanotubes on nano-patterned substrate by imprint method

    Energy Technology Data Exchange (ETDEWEB)

    Chang, W.S., E-mail: paul@kimm.re.kr [Department of Nano Mechanics, Korea Institute of Machinery and Materials, 104 Sinseongno, Yuseong-gu Daejeon 305-343 (Korea, Republic of); Kim, J.W. [Gyeongbuk Hybrid Technology Institute, 36 Goeyeon-dong, Yeongcheon, Gyeongbuk 770-170 (Korea, Republic of); Choi, D.G. [Department of Nano Mechanics, Korea Institute of Machinery and Materials, 104 Sinseongno, Yuseong-gu Daejeon 305-343 (Korea, Republic of); Han, C.S. [Gyeongbuk Hybrid Technology Institute, 36 Goeyeon-dong, Yeongcheon, Gyeongbuk 770-170 (Korea, Republic of)

    2011-01-15

    The synthesis of isolated carbon nanotubes with uniform outer diameters and ordered spacing over wafer-scale areas was investigated for fabrication of nano-electrode arrays on silicon wafers for field emission and sensor devices. Multi-walled carbon nanotubes (MWCNTs) were grown on TiN electrode layer with iron catalyst patterned by nano-imprint lithography (NIL), which allows the precise placement of individual CNTs on a substrate. The proposed techniques, including plasma-enhanced chemical vapor deposition (PECVD) and NIL, are simple, inexpensive, and reproducible methods for fabrication of nano-scale devices in large areas. The catalyst patterns were defined by an array of circles with 200 nm in diameter, and variable lengths of pitch. The nano-patterned master and Fe catalyst were observed with good pattern fidelity over a large area by atomic force microscope (AFM) and scanning electron microscopy (SEM). Nano-electrodes of MWCNTs had diameters ranging from 50 nm to 100 nm and lengths of about 300 nm. Field emission tests showed the reducing ignition voltage as the geometry of nanotube arrays was controlled by catalyst patterning. These results showed a wafer-scale approach to the control of the size, pitch, and position of nano-electrodes of nanotubes for various applications including electron field-emission sources, electrochemical probes, functionalized sensor elements, and so on.

  10. Non-adherence to anti-TB drugs among TB/HIV co-infected patients ...

    African Journals Online (AJOL)

    Non-adherence to anti-TB drugs among TB/HIV co-infected patients in Mbarara Hospital ... and its associated factors have not been studied in these patients in Uganda. ... Methods: A cross-sectional study with qualitative and quantitative data ...

  11. Cermet electrode

    Science.gov (United States)

    Maskalick, Nicholas J.

    1988-08-30

    Disclosed is a cermet electrode consisting of metal particles of nickel, cobalt, iron, or alloys or mixtures thereof immobilized by zirconia stabilized in cubic form which contains discrete deposits of about 0.1 to about 5% by weight of praseodymium, dysprosium, terbium, or a mixture thereof. The solid oxide electrode can be made by covering a substrate with particles of nickel, cobalt, iron, or mixtures thereof, growing a stabilized zirconia solid oxide skeleton around the particles thereby immobilizing them, contacting the skeleton with a compound of praseodymium, dysprosium, terbium, or a mixture thereof, and heating the skeleton to a temperature of at least 500.degree. C. The electrode can also be made by preparing a slurry of nickel, cobalt, iron, or mixture and a compound of praseodymium, dysprosium, terbium, or a mixture thereof, depositing the slurry on a substrate, heating the slurry to dryness, and growing a stabilized zirconia skeleton around the metal particles.

  12. Sandwich-type electrode

    Science.gov (United States)

    Lu, Wen-Tong P.; Garcia, Earl R.

    1983-01-01

    Disclosed is an improvement on a method of making an electrode wherein a suspension in a liquid is prepared of a powdered catalyst containing a noble metal, carbon powder and a binder, and the suspension is poured over a carbon substrate dried, compressed and sintered to form a solid catalyst layer bonded to the carbon substrate. The improvement is placing a carbon paper on the catalyst layer prior to compressing. The improved electrode can be used as either a cathode or an anode in a sulfur dioxide depolarized electrolyzer in a process for producing hydrogen from water.

  13. Theoretical and experimental study of the bending influence on the capacitance of interdigitated micro-electrodes patterned on flexible substrates

    International Nuclear Information System (INIS)

    Molina-Lopez, F.; Briand, D.; Rooij, N. F. de; Kinkeldei, T.; Tröster, G.

    2013-01-01

    Interdigitated electrodes are common structures in the fields of microelectronics and MEMS. Recent developments in flexible electronics compel an understanding of such structures under bending constraints. In this work, the behavior of interdigitated micro-electrodes when subjected to circular bending has been theoretically and experimentally studied through changes in capacitance. An analytical model has been developed to calculate the expected variation in capacitance of such structures while undergoing outward and inward bending along the direction perpendicular to the electrodes. The model combines conformal mapping techniques to account for the electric field redistribution and fundamental aspects of solid mechanics in order to define the geometrical deformation of the electrodes while bending. To experimentally verify our theoretical predictions, several interdigitated electrode structures with different geometries were fabricated on polymeric substrates by means of photolithography. The samples, placed in a customized bending setup, were bent to controlled radii of curvature while measuring their capacitance. A maximum variation in capacitance of less than 3% was observed at a minimum radius of curvature of 2.5 mm for all the devices tested with very thin electrodes whereas changes of up to 7% were found on stiffer, plated electrodes. Larger or smaller variations would be possible, in theory, by adjusting the geometry of the device. This work establishes a useful predictive tool for the design and evaluation of truly flexible/bendable electronics consisting of interdigitated structures, allowing one to tune the bending influence on the capacitance value through geometrical design

  14. Unique structural modulation of a non-native substrate by cochaperone DnaJ.

    Science.gov (United States)

    Tiwari, Satyam; Kumar, Vignesh; Jayaraj, Gopal Gunanathan; Maiti, Souvik; Mapa, Koyeli

    2013-02-12

    The role of bacterial DnaJ protein as a cochaperone of DnaK is strongly appreciated. Although DnaJ unaccompanied by DnaK can bind unfolded as well as native substrate proteins, its role as an individual chaperone remains elusive. In this study, we demonstrate that DnaJ binds a model non-native substrate with a low nanomolar dissociation constant and, more importantly, modulates the structure of its non-native state. The structural modulation achieved by DnaJ is different compared to that achieved by the DnaK-DnaJ complex. The nature of structural modulation exerted by DnaJ is suggestive of a unique unfolding activity on the non-native substrate by the chaperone. Furthermore, we demonstrate that the zinc binding motif along with the C-terminal substrate binding domain of DnaJ is necessary and sufficient for binding and the subsequent binding-induced structural alterations of the non-native substrate. We hypothesize that this hitherto unknown structural alteration of non-native states by DnaJ might be important for its chaperoning activity by removing kinetic traps of the folding intermediates.

  15. MAGNETIC ARC WELDING STABILIZATION USING NON-CONSUMABLE ELECTRODE

    Directory of Open Access Journals (Sweden)

    Павло Юрійович Сидоренко

    2017-06-01

    Full Text Available Results of development torch to magnetically operated   welding arc are defined. Changing the design of the electrode unit is provided the ability to create within the area of the arc magnetic field and induction given configuration without additional equipment. The features of the arc in an axial magnetic field which make it possible to avoid the welding process of unsteady abnormalities resulted in the inappropriate formation of defects in welds. Significant increase in the depth of  weld penetration is connected with the more concentrated magnetically operated   welding arc transmission energy to the product. It is concluded about the feasibility of using a designed torch for the implementation of modern technological processes non-consumable electrode welding.

  16. Nanowire-decorated microscale metallic electrodes

    DEFF Research Database (Denmark)

    Vlad, A.; Mátéfi-Tempfli, M.; Antohe, V.A.

    2008-01-01

    The fabrication of metallic nanowire patterns within anodic alumina oxide (AAO) membranes on top of continuous conducting substrates are discussed. The fabrication protocol is based on the realization of nanowire patterns using supported nanoporous alumina templates (SNAT) prepared on top...... of lithographically defined metallic microelectrodes. The anodization of the aluminum permits electroplating only on top of the metallic electrodes, leading to the nanowire patterns having the same shape as the underlying metallic tracks. The variation in the fabricated structures between the patterned and non......-patterned substrates can be interpreted in terms of different behavior during anodization. The improved quality of fabricated nanowire patterns is clearly demonstrated by the SEM imaging and the uniform growth of nanowires inside the alumina template is observed without any significant height variation....

  17. In situ diazonium-modified flexible ITO-coated PEN substrates for the deposition of adherent silver-polypyrrole nanocomposite films.

    Science.gov (United States)

    Samanta, Soumen; Bakas, Idriss; Singh, Ajay; Aswal, Dinesh K; Chehimi, Mohamed M

    2014-08-12

    In this paper, we report a simple and versatile process of electrografting the aryl multilayers onto indium tin oxide (ITO)-coated flexible poly(ethylene naphthalate) (PEN) substrates using a diazonium salt (4-pyrrolylphenyldiazonium) solution, which was generated in situ from a reaction between the 4-(1H-pyrrol-1-yl)aniline precursor and sodium nitrite in an acidic medium. The first aryl layer bonds with the ITO surface through In-O-C and Sn-O-C bonds which facilitate the formation of a uniform aryl multilayer that is ∼8 nm thick. The presence of the aryl multilayer has been confirmed by impedance spectroscopy as well as by electron-transfer blocking measurements. These in situ diazonium-modified ITO-coated PEN substrates may find applications in flexible organic electronics and sensor industries. Here we demonstrate the application of diazonium-modified flexible substrates for the growth of adherent silver/polpyrrole nanocomposite films using surface-confined UV photopolymerization. These nanocomposite films have platelet morphology owing to the template effect of the pyrrole-terminated aryl multilayers. In addition, the films are highly doped (32%). This work opens new areas in the design of flexible ITO-conductive polymer hybrids.

  18. Prevalence and correlates of medication non-adherence among kidney transplant recipients more than 6 months post-transplant: a cross-sectional study

    OpenAIRE

    Weng, Francis L; Chandwani, Sheenu; Kurtyka, Karen M; Zacker, Christopher; Chisholm-Burns, Marie A; Demissie, Kitaw

    2013-01-01

    Background Among kidney transplant recipients, non-adherence with immunosuppressive medications frequently precedes allograft loss. We sought to determine the prevalence and correlates of medication non-adherence among kidney transplant recipients. Methods We performed a single-center, cross-sectional study of kidney transplant recipients who were at least 6 months post-transplant. We measured self-reported adherence using the Immunosuppressive Therapy Adherence Scale (ITAS, which is scored f...

  19. Selective detection and recovery of gold at tannin-immobilized non-conducting electrode

    Energy Technology Data Exchange (ETDEWEB)

    Banu, Khaleda, E-mail: kbanu@ucla.edu [Department of Molecular and Medical Pharmacology, University of California, Los Angeles, CA 90095 (United States); Venture Business Laboratory, Center for Advanced Science and Innovation, Osaka University, Suita, Osaka 565-0871 (Japan); Shimura, Takayoshi [Venture Business Laboratory, Center for Advanced Science and Innovation, Osaka University, Suita, Osaka 565-0871 (Japan); Department of Material and Life Science, Division of Advanced Science and Biotechnology, Graduate School of Engineering, Osaka University (Japan); Sadeghi, Saman, E-mail: samsadeghi@mednet.ucla.edu [Department of Molecular and Medical Pharmacology, University of California, Los Angeles, CA 90095 (United States)

    2015-01-01

    Highlights: • Selective detection of gold at non-conducting (NC) polymer modified electrode. • Mimosa tannin oxidized on glassy carbon electrode surface as NC polymeric film. • Permselective diffusion and mediated electron transfer at NC electrode surface. • Chemical recovery of gold is due to the reducing ability of the NC polymeric film. • Adsorption capacity of Au(III) on carbon fiber was 29 ± 1.45 mg g{sup −1} at 60 °C. - Abstract: A tannin-immobilized glassy carbon electrode (TIGC) was prepared via electrochemical oxidation of the naturally occurring polyphenolic mimosa tannin, which generated a non-conducting polymeric film (NCPF) on the electrode surface. The fouling of the electrode surface by the electropolymerized film was evaluated by monitoring the electrode response of ferricyanide ions as a redox marker. The NCPF was permselective to HAuCl{sub 4}, and the electrochemical reduction of HAuCl{sub 4} to metallic gold at the TIGC electrode was evaluated by recording the reduction current during cyclic voltammetry measurement. In the mixed electrolyte containing HAuCl{sub 4} along with FeCl{sub 3} and/or CuCl{sub 2}, the NCPF remained selective toward the electrochemical reduction of HAuCl{sub 4} into the metallic state. The chemical reduction of HAuCl{sub 4} into metallic gold was also observed when the NCPF was inserted into an acidic gold solution overnight. The adsorption capacity of Au(III) on tannin-immobilized carbon fiber was 29 ± 1.45 mg g{sup −1} at 60 °C. In the presence of excess Cu(II) and Fe(III), tannin-immobilized NCPF proved to be an excellent candidate for the selective detection and recovery of gold through both electrochemical and chemical processes.

  20. Selective detection and recovery of gold at tannin-immobilized non-conducting electrode

    International Nuclear Information System (INIS)

    Banu, Khaleda; Shimura, Takayoshi; Sadeghi, Saman

    2015-01-01

    Highlights: • Selective detection of gold at non-conducting (NC) polymer modified electrode. • Mimosa tannin oxidized on glassy carbon electrode surface as NC polymeric film. • Permselective diffusion and mediated electron transfer at NC electrode surface. • Chemical recovery of gold is due to the reducing ability of the NC polymeric film. • Adsorption capacity of Au(III) on carbon fiber was 29 ± 1.45 mg g −1 at 60 °C. - Abstract: A tannin-immobilized glassy carbon electrode (TIGC) was prepared via electrochemical oxidation of the naturally occurring polyphenolic mimosa tannin, which generated a non-conducting polymeric film (NCPF) on the electrode surface. The fouling of the electrode surface by the electropolymerized film was evaluated by monitoring the electrode response of ferricyanide ions as a redox marker. The NCPF was permselective to HAuCl 4 , and the electrochemical reduction of HAuCl 4 to metallic gold at the TIGC electrode was evaluated by recording the reduction current during cyclic voltammetry measurement. In the mixed electrolyte containing HAuCl 4 along with FeCl 3 and/or CuCl 2 , the NCPF remained selective toward the electrochemical reduction of HAuCl 4 into the metallic state. The chemical reduction of HAuCl 4 into metallic gold was also observed when the NCPF was inserted into an acidic gold solution overnight. The adsorption capacity of Au(III) on tannin-immobilized carbon fiber was 29 ± 1.45 mg g −1 at 60 °C. In the presence of excess Cu(II) and Fe(III), tannin-immobilized NCPF proved to be an excellent candidate for the selective detection and recovery of gold through both electrochemical and chemical processes

  1. Enhanced Output Power of PZT Nanogenerator by Controlling Surface Morphology of Electrode.

    Science.gov (United States)

    Jung, Woo-Suk; Lee, Won-Hee; Ju, Byeong-Kwon; Yoon, Seok-Jin; Kang, Chong-Yun

    2015-11-01

    Piezoelectric power generation using Pb(Zr,Ti)O3(PZT) nanowires grown on Nb-doped SrTiO3(nb:STO) substrate has been demonstrated. The epitaxial PZT nanowires prepared by a hydrothermal method, with a diameter and length of approximately 300 nm and 7 μm, respecively, were vertically aligned on the substrate. An embossed Au top electrode was applied to maximize the effective power generation area for non-uniform PZT nanowires. The PZT nanogenerator produced output power density of 0.56 μW/cm2 with a voltage of 0.9 V and current of 75 nA. This research suggests that the morphology control of top electrode can be useful to improve the efficiency of piezoelectric power generation.

  2. Medication non-adherence and uncertainty: Information-seeking and processing in the Danish LIFESTAT survey.

    Science.gov (United States)

    Kriegbaum, Margit; Lau, Sofie Rosenlund

    2017-09-23

    Statins are widely prescribed to lower cardiovascular morbidity and mortality. However, statin non-adherence is very high. The aim of this paper was to investigate reasons for stopping statin treatment in the general population and to study how aspects of information-seeking and processing is associated with statin non-adherence. This study used a population survey on 3050 Danish residents aged 45-65 years. Reasons for statin discontinuation was studied among those who were previous statin users. The association between information seeking and processing and statin discontinuation were analysed using multivariate logistical regression models. Experience of side effects and fear of side effects played an important role in the discontinuation of statin treatment. Feelings of uncertainty and confusion regarding information on statins predicted statin discontinuation. This applied to information from both mass media and from general practitioners. There was no clear pattern of information seeking and statin non-adherence. The article point to the impact of information-seeking on the decision to take cholesterol-lowering medication. This included contributions from information disseminated by media outlets. Side effects and fear of side effects should be addressed in clinical practice. Health care professionals should pay attention to emotional aspects of how information is disseminated and perceived by statin users. Copyright © 2017. Published by Elsevier Inc.

  3. Adherence with Preventive Medication in Childhood Asthma

    Directory of Open Access Journals (Sweden)

    Scott Burgess

    2011-01-01

    Full Text Available Suboptimal adherence with preventive medication is common and often unrecognised as a cause of poor asthma control. A number of risk factors for nonadherence have emerged from well-conducted studies. Unfortunately, patient report a physician's estimation of adherence and knowledge of these risk factors may not assist in determining whether non-adherence is a significant factor. Electronic monitoring devices are likely to be more frequently used to remind patients to take medication, as a strategy to motivate patients to maintain adherence, and a tool to evaluate adherence in subjects with poor disease control. The aim of this paper is to review non-adherence with preventive medication in childhood asthma, its impact on asthma control, methods of evaluating non-adherence, risk factors for suboptimal adherence, and strategies to enhance adherence.

  4. The rate and factors associated with non-adherence to surgery, chemotherapy, radiotherapy and hormonal therapy among breast cancer patients attending public hospitals in Malaysia

    Directory of Open Access Journals (Sweden)

    Nur Aishah Taib

    2017-12-01

    Full Text Available Background: The role of breast cancer treatments in reducing recurrence and death has been established. However, the treatments side effects greatly impact on quality of life and little is known about the non-adherence rates. The purpose of this study was to determine the non-adherence rates to surgery, chemotherapy, radiotherapy and hormonal therapy, and factors that affect it in public hospitals in Malaysia. Methods: A multicentre cross-sectional study was conducted in six public hospitals involving all newly diagnosed breast cancer patients in 2012. Data were collected through medical record reviews and interview by using structured questionnaire. Non-adherence was categorized as any breast cancer patients refusing or discontinuing any treatment due to non-medical reasons. Univariable logistic regression and multiple logistic regressions were used for analysis. Results: A total of 340 breast cancer patients were included in the study. The proportion for non-adherence to surgery, chemotherapy, radiotherapy and hormonal therapy were 14%, 30.1%, 33.3% and 36.3% respectively. Factors associated with non-adherence to surgery were localities involving Kuala Lumpur (2 (OR: 3.41, Johor (OR: 8.38 and Kelantan (OR: 6.32, and those required mastectomy (OR: 5.66. No factors were found to be associated with non-adherence to chemotherapy, radiotherapy and hormonal therapy. These three treatment modalities were then combined as oncology therapy and the only independent factor associated with non-adherence to oncology therapy was Perak locality (OR: 1.42. Conclusion: Non-adherence to breast cancer treatments was high among breast cancer patients at public hospitals in Malaysia. Factors influencing non-adherence were locations and mastectomy implicating of socio-culture, body image issues, psychological disturbance and treatment navigation. Community educational programs focusing on correcting misconceptions, treatment outcomes and treatments’ side effects

  5. Live-cell calcium imaging of adherent and non-adherent GL261 cells reveals phenotype-dependent differences in drug responses.

    Science.gov (United States)

    Strong, Averey D; Daniels, Richard L

    2017-08-02

    The tumor-derived GL261 cell line is used as a model for studying glioblastoma and other high-grade gliomas, and can be cultured adherently or as free-floating aggregates known as neurospheres. These different culture conditions give rise to distinct phenotypes, with increased tumorigenicity displayed by neurosphere-cultured cells. An important technique for understanding GL261 pathobiology is live cell fluorescent imaging of intracellular calcium. However, live cell imaging of GL261 neurospheres presents a technical challenge, as experimental manipulations where drugs are added to the extracellular media cause the cells to move during analysis. Here we present a method to immobilize GL261 neurospheres with low melting point agarose for calcium imaging using the fluorescent calcium sensor fura-2. GL261 cells were obtained from the NCI-Frederick Cancer Research Tumor Repository and cultured as adherent cells or induced to form neurospheres by placing freshly trypsinized cells into serum-free media containing fibroblast growth factor 2, epidermal growth factor, and B-27 supplement. Prior to experiments, adherent cells were loaded with fura-2 and cultured on 8-well chamber slides. Non-adherent neurospheres were first loaded with fura-2, placed in droplets onto an 8-well chamber slide, and finally covered with a thin layer of low melting point agarose to immobilize the cells. Ratiometric pseudocolored images were obtained during treatment with ATP, capsaicin, or vehicle control. Cells were marked as responsive if fluorescence levels increased more than 30% above baseline. Differences between treatment groups were tested using Student's t-tests and one-way ANOVA. We found that cellular responses to pharmacological treatments differ based on cellular phenotype. Adherent cells and neurospheres both responded to ATP with a rise in intracellular calcium. Notably, capsaicin treatment led to robust responses in GL261 neurospheres but not adherent cells. We demonstrate the use

  6. Spot morphology of non-contact printed protein molecules on non-porous substrates with a range of hydrophobicities

    NARCIS (Netherlands)

    Mujawar, L.H.; Norde, W.; Amerongen, van A.

    2013-01-01

    Non-contact inkjet printing technology is one of the most promising tools for producing microarrays. The quality of the microarray depends on the type of the substrate used for printing biomolecules. Various porous and non-porous substrates have been used in the past, but due to low production cost

  7. Dimensionally stable PbO{sub 2} electrodes for lead acid batteries

    Energy Technology Data Exchange (ETDEWEB)

    Devilliers, D.; Devos, B.; Groult, H. [Pierre et Marie Curie Univ., Paris (France). Laboratoire LI2C-Electrochimie

    2007-07-15

    Dimensionally stable anodes (DSAs) are regularly used in industrial electrolytic cells. The titanium substrate in these electrodes is covered by an electrocatalytic layer containing a precious metal oxide. The concept of PbO{sub 2}-dimensionally stable electrodes with a light metal substrate may also be applied to generators, particularly for bipolar lead acid batteries. However, one of the issues with bipolar lead-acid batteries is the stability of the bipolar electrode substrate, particularly on the side onto which the positive active mass is deposited. This article presented the results of a study that characterized the performance of different electrode substrates onto which PbO{sub 2} was electrodeposited using cyclic voltammetry performed with PbO{sub 2} in sulphuric acid. The article discussed the experiment with reference to the titanium substrates; modification of the substrates; x-ray diffraction; and cyclic voltammetry experiments with PbO{sub 2} electrodes. It also presented a discussion of the results. The study concluded that titanium covered by the mixed oxides layer titanium dioxide (TiO{sub 2})-tin dioxide (SnO{sub 2})-antimony oxide (Sb{sub 2}O{sub 3}) constitutes a suitable substrate for PbO{sub 2} electrodes. It can be used in lead acid batteries and allows the preparation of compact bipolar batteries. 36 refs., 1 tab., 5 figs.

  8. Accurate measurement of the piezoelectric coefficient of thin films by eliminating the substrate bending effect using spatial scanning laser vibrometry

    International Nuclear Information System (INIS)

    Leighton, Glenn J T; Huang, Zhaorong

    2010-01-01

    One of the major difficulties in measuring the piezoelectric coefficient d 33,f for thin films is the elimination of the contribution from substrate bending. We show by theoretical analysis and experimental measurements that by bonding thin film piezoelectric samples to a substantial holder, the substrate bending can be minimized to a negligible level. Once the substrate bending can be effectively eliminated, single-beam laser scanning vibrometry can be used to measure the precise strain distribution of a piezoelectric thin film under converse actuation. A significant strain increase toward the inside edge of the top electrode (assuming a fully covered bottom electrode) and a corresponding strain peak in the opposite direction just outside the electrode edge were observed. These peaks were found to increase with the increasing Poisson's ratio and transverse piezoelectric coefficient of the piezoelectric thin film. This is due to the non-continuity of the electric field at the edge of the top electrode, which leads to the concentration of shear stress and electric field in the vicinity of the electrode edge. The measured d 33,f was found to depend not only on the material properties such as the electromechanical coefficients of the piezoelectric thin films and elastic coefficients of the thin film and the substrate, but also on the geometry factors such as the thickness of the piezoelectric films, the dimensions of the electrode, and also the thickness of the substrate

  9. Muscle-derived stem cells isolated as non-adherent population give rise to cardiac, skeletal muscle and neural lineages

    International Nuclear Information System (INIS)

    Arsic, Nikola; Mamaeva, Daria; Lamb, Ned J.; Fernandez, Anne

    2008-01-01

    Stem cells with the ability to differentiate in specialized cell types can be extracted from a wide array of adult tissues including skeletal muscle. Here we have analyzed a population of cells isolated from skeletal muscle on the basis of their poor adherence on uncoated or collagen-coated dishes that show multi-lineage differentiation in vitro. When analysed under proliferative conditions, these cells express stem cell surface markers Sca-1 (65%) and Bcrp-1 (80%) but also MyoD (15%), Neuronal β III-tubulin (25%), GFAP (30%) or Nkx2.5 (1%). Although capable of growing as non-attached spheres for months, when given an appropriate matrix, these cells adhere giving rise to skeletal muscle, neuronal and cardiac muscle cell lineages. A similar cell population could not be isolated from either bone marrow or cardiac tissue suggesting their specificity to skeletal muscle. When injected into damaged muscle, these non-adherent muscle-derived cells are retrieved expressing Pax7, in a sublaminar position characterizing satellite cells and participate in forming new myofibers. These data show that a non-adherent stem cell population can be specifically isolated and expanded from skeletal muscle and upon attachment to a matrix spontaneously differentiate into muscle, cardiac and neuronal lineages in vitro. Although competing with resident satellite cells, these cells are shown to significantly contribute to repair of injured muscle in vivo supporting that a similar muscle-derived non-adherent cell population from human muscle may be useful in treatment of neuromuscular disorders

  10. Muscle-derived stem cells isolated as non-adherent population give rise to cardiac, skeletal muscle and neural lineages.

    Science.gov (United States)

    Arsic, Nikola; Mamaeva, Daria; Lamb, Ned J; Fernandez, Anne

    2008-04-01

    Stem cells with the ability to differentiate in specialized cell types can be extracted from a wide array of adult tissues including skeletal muscle. Here we have analyzed a population of cells isolated from skeletal muscle on the basis of their poor adherence on uncoated or collagen-coated dishes that show multi-lineage differentiation in vitro. When analysed under proliferative conditions, these cells express stem cell surface markers Sca-1 (65%) and Bcrp-1 (80%) but also MyoD (15%), Neuronal beta III-tubulin (25%), GFAP (30%) or Nkx2.5 (1%). Although capable of growing as non-attached spheres for months, when given an appropriate matrix, these cells adhere giving rise to skeletal muscle, neuronal and cardiac muscle cell lineages. A similar cell population could not be isolated from either bone marrow or cardiac tissue suggesting their specificity to skeletal muscle. When injected into damaged muscle, these non-adherent muscle-derived cells are retrieved expressing Pax7, in a sublaminar position characterizing satellite cells and participate in forming new myofibers. These data show that a non-adherent stem cell population can be specifically isolated and expanded from skeletal muscle and upon attachment to a matrix spontaneously differentiate into muscle, cardiac and neuronal lineages in vitro. Although competing with resident satellite cells, these cells are shown to significantly contribute to repair of injured muscle in vivo supporting that a similar muscle-derived non-adherent cell population from human muscle may be useful in treatment of neuromuscular disorders.

  11. Photosensitive-polyimide based method for fabricating various neural electrode architectures

    Directory of Open Access Journals (Sweden)

    Yasuhiro X Kato

    2012-06-01

    Full Text Available An extensive photosensitive polyimide (PSPI-based method for designing and fabricating various neural electrode architectures was developed. The method aims to broaden the design flexibility and expand the fabrication capability for neural electrodes to improve the quality of recorded signals and integrate other functions. After characterizing PSPI’s properties for micromachining processes, we successfully designed and fabricated various neural electrodes even on a non-flat substrate using only one PSPI as an insulation material and without the time-consuming dry etching processes. The fabricated neural electrodes were an electrocorticogram electrode, a mesh intracortical electrode with a unique lattice-like mesh structure to fixate neural tissue, and a guide cannula electrode with recording microelectrodes placed on the curved surface of a guide cannula as a microdialysis probe. In vivo neural recordings using anesthetized rats demonstrated that these electrodes can be used to record neural activities repeatedly without any breakage and mechanical failures, which potentially promises stable recordings for long periods of time. These successes make us believe that this PSPI-based fabrication is a powerful method, permitting flexible design and easy optimization of electrode architectures for a variety of electrophysiological experimental research with improved neural recording performance.

  12. Label-free and substrate-free potentiometric aptasensing using polycation-sensitive membrane electrodes.

    Science.gov (United States)

    Ding, Jiawang; Chen, Yan; Wang, Xuewei; Qin, Wei

    2012-02-21

    A potentiometric label-free and substrate-free (LFSF) aptasensing strategy which eliminates the labeling, separation, and immobilization steps is described in this paper. An aptamer binds specifically to a target molecule via reaction incubation, which could induce a change in the aptamer conformation from a random coil-like configuration to a rigid folded structure. Such a target binding-induced aptamer conformational change effectively prevents the aptamer from electrostatically interacting with the protamine binding domain. This could either shift the response curve for the potentiometric titration of the aptamer with protamine as monitored by a conventional polycation-sensitive membrane electrode or change the current-dependent potential detected by a protamine-conditioned polycation-sensitive electrode with the pulsed current-driven ion fluxes of protamine across the polymeric membrane. Using adenosine triphosphate (ATP) as a model analyte, the proposed concept offers potentiometric detection of ATP down to the submicromolar concentration range and has been applied to the determination of ATP in HeLa cells. In contrast to the current LFSF aptasensors based on optical detection, the proposed strategy allows the LFSF biosensing of aptamer/target binding events in a homogeneous solution via electrochemical transduction. It is anticipated that the proposed strategy will lay a foundation for development of potentiometric sensors for LFSF aptasensing of a variety of analytes where target binding-induced conformational changes such as the formation of folded structures and the opening of DNA hairpin loops are involved.

  13. The Relationship Between Treatment Adherence and Non-picked Up Medications in Community Pharmacies

    Directory of Open Access Journals (Sweden)

    Vu Phan Hoang Nguyen

    2016-10-01

    Full Text Available Medication adherence is one of the major factors that determine an outcome of a treatment. Despite the effort of healthcare providers to improve the adherence rate, it still remains a serious issue in our health care system today. Many patients do not take their medications as directed or just simply do not want to fill or refill their prescriptions. A small survey performed by pharmacy students at Temple School of Pharmacy showed that there is a significant number of patients did not pick up their medications. Cardiovascular medications are the most common non-picked up drugs. There are various reasons that patients use to justify for this non-adherence behavior. However, they are unaware that their actions create a tremendous negative effect not only on the treatment itself but also on the entire health care system. The consequences include expensive therapies, inaccurate research data, and poor treatment outcomes. Many solutions have been utilized to solve this problem, but it is still the major problem for healthcare providers to keep in mind when planning a drug regimen. Although many people believed that pharmacists are responsible for solving this problem, it should be a multidisciplinary effort of all healthcare providers to improve the medication adherence. Conflict of Interest We declare no conflicts of interest or financial interests that the authors or members of their immediate families have in any product or service discussed in the manuscript, including grants (pending or received, employment, gifts, stock holdings or options, honoraria, consultancies, expert testimony, patents and royalties.   Type: Student Project

  14. Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Gang; Shu, Honghui; Ji, Kai [Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Faculty of Materials Science and Engineering, Hubei University, No. 368 Youyi Avenue, Wuchang, Wuhan 430062 (China); Oyama, Munetaka [Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Nishikyo-ku, Kyoto 615-8520 (Japan); Liu, Xiong [Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Faculty of Materials Science and Engineering, Hubei University, No. 368 Youyi Avenue, Wuchang, Wuhan 430062 (China); He, Yunbin, E-mail: ybhe@hubu.edu.cn [Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Faculty of Materials Science and Engineering, Hubei University, No. 368 Youyi Avenue, Wuchang, Wuhan 430062 (China)

    2014-01-01

    This work describes controllable preparation of gold nanoparticles on glassy carbon electrodes by using the seed mediated growth method, which contains two steps, namely, nanoseeds attachment and nanocrystals growth. The size and the dispersion of gold nanoparticles grown on glassy carbon electrodes could be easily tuned through the growth time based on results of field-emission scanning electron microscopy. Excellent electrochemical catalytic characteristics for glucose oxidation were observed for the gold nanoparticles modified glassy carbon electrodes (AuNPs/GC), resulting from the extended active surface area provided by the dense gold nanoparticles attached. It exhibited a wide linear range from 0.1 mM to 25 mM with the sensitivity of 87.5 μA cm{sup −2} mM{sup −1} and low detection limit down to 0.05 mM for the sensing of glucose. The common interfering species such as chloride ion, ascorbic acid, uric acid and 4-acetamidophenol were verified having no interference effect on the detection of glucose. It is demonstrated that the seed mediated method is one of the facile approaches for fabricating Au nanoparticles modified substrates, which could work as one kind of promising electrode materials for the glucose nonenzymatic sensing.

  15. A transparent conductive oxide electrode with highly enhanced flexibility achieved by controlled crystallinity by incorporating Ag nanoparticles on substrates

    Energy Technology Data Exchange (ETDEWEB)

    Triambulo, Ross E.; Cheong, Hahn-Gil [Department of Materials Science and Engineering, Yonsei University, Seoul (Korea, Republic of); Lee, Gun-Hwan [Advanced Thin Film Research Group, Korea Institute of Materials Science (KIMS), Changwon (Korea, Republic of); Yi, In-Sook [R and D Center, InkTec Co., Ltd., Ansan (Korea, Republic of); Park, Jin-Woo, E-mail: jwpark09@yonsei.ac.kr [Department of Materials Science and Engineering, Yonsei University, Seoul (Korea, Republic of)

    2015-01-25

    Highlights: • We developed a composite transparent electrode with Ag nanoparticles and indium-tin-oxide. • Transmittance of AgNPs was improved by formation of oxide layers by O{sub 2} plasma treatment. • Ag nanoparticles became crystalline seeds to grow strong ITO with a uniform growth orientation. • The hybrid electrode is highly more conductive and stable under bending than ITO. - Abstract: We report the synthesis of highly flexible indium tin oxide (ITO) on a polymer substrate whose surface was engineered by oxide-coated Ag nanoparticles (AgNPs) smaller than 20 nm in diameter. Polyimide (PI) substrates were spin coated with Ag ion ink and were subsequently heat treated to form AgNP coatings. The Ag oxide was formed by O{sub 2} plasma treatment to reduce the light absorbance by AgNPs. ITO was dc magnetron sputter-deposited atop the AgNPs. The ITO on the AgNPs was crystalline grown primarily with (2 2 2) growth orientation. This contrasts to the typical microstructure of ITO grown on the polymer, which is that growing c-ITO nucleates are embedded in an amorphous ITO (a-ITO) matrix like a particulate composite. The surface roughness of ITO on AgNPs was as small as the ITO on PI without AgNPs. The crystalline nature of the ITO on the AgNP-coated polymer resulted in the decrease of electric resistivity (ρ) by 65% compared to that of ITO on the bare PI. Furthermore, an electric resistivity change (Δρ) of the ITO on the AgNPs was only 8% at a bending radius (r{sub b}) down to 4 mm, whereas the ITO on the non-coated polymer became almost insulating at an r{sub b} of 10 mm, owing to a drastic increase in the number of cracks. To validate the potential application in the displays, flexible organic light emitting diodes (f-OLEDs) were fabricated on the ITO on AgNPs and the performances was compared with the f-OLED on ITO on the bare PI.

  16. A transparent conductive oxide electrode with highly enhanced flexibility achieved by controlled crystallinity by incorporating Ag nanoparticles on substrates

    International Nuclear Information System (INIS)

    Triambulo, Ross E.; Cheong, Hahn-Gil; Lee, Gun-Hwan; Yi, In-Sook; Park, Jin-Woo

    2015-01-01

    Highlights: • We developed a composite transparent electrode with Ag nanoparticles and indium-tin-oxide. • Transmittance of AgNPs was improved by formation of oxide layers by O 2 plasma treatment. • Ag nanoparticles became crystalline seeds to grow strong ITO with a uniform growth orientation. • The hybrid electrode is highly more conductive and stable under bending than ITO. - Abstract: We report the synthesis of highly flexible indium tin oxide (ITO) on a polymer substrate whose surface was engineered by oxide-coated Ag nanoparticles (AgNPs) smaller than 20 nm in diameter. Polyimide (PI) substrates were spin coated with Ag ion ink and were subsequently heat treated to form AgNP coatings. The Ag oxide was formed by O 2 plasma treatment to reduce the light absorbance by AgNPs. ITO was dc magnetron sputter-deposited atop the AgNPs. The ITO on the AgNPs was crystalline grown primarily with (2 2 2) growth orientation. This contrasts to the typical microstructure of ITO grown on the polymer, which is that growing c-ITO nucleates are embedded in an amorphous ITO (a-ITO) matrix like a particulate composite. The surface roughness of ITO on AgNPs was as small as the ITO on PI without AgNPs. The crystalline nature of the ITO on the AgNP-coated polymer resulted in the decrease of electric resistivity (ρ) by 65% compared to that of ITO on the bare PI. Furthermore, an electric resistivity change (Δρ) of the ITO on the AgNPs was only 8% at a bending radius (r b ) down to 4 mm, whereas the ITO on the non-coated polymer became almost insulating at an r b of 10 mm, owing to a drastic increase in the number of cracks. To validate the potential application in the displays, flexible organic light emitting diodes (f-OLEDs) were fabricated on the ITO on AgNPs and the performances was compared with the f-OLED on ITO on the bare PI

  17. Carbon black nanoparticles film electrode prepared by using substrate-induced deposition approach

    Energy Technology Data Exchange (ETDEWEB)

    Svegl, Irena Grabec; Bele, Marjan [National Institute of Chemistry, P.O. Box 660, SI-1001 Ljubljana (Slovenia); Ogorevc, Bozidar [National Institute of Chemistry, P.O. Box 660, SI-1001 Ljubljana (Slovenia)], E-mail: bogorevc@ki.si

    2008-11-03

    A new type of carbon film electrode, composed of a thin layer of tightly packed carbon black (CB) nanoparticles deposited onto a gelatin-covered indium tin oxide/glass support using the surface-induced deposition (SID) approach, is presented. Some parameters of the novel SID method were optimized and the surface image and functionalization of the investigated carbon black film electrode (CBFE) was inspected by employing scanning electron microscopy and infrared spectroscopy. A cyclic voltammetry (CV) study was conducted in which the electron-transfer kinetics and CBFE interfacial characteristics were evaluated employing several selected reference redox systems, such as [Ru(NH{sub 3}){sub 6}]{sup 3+/2+}, [Fe(CN){sub 6}]{sup 3-/4-} and Fe{sup 3+/2+} in aqueous, and ferrocene/ferrocenium in acetonitrile media. CV recordings were also performed in order to compare the electrochemical behavior of the CBFE with that of some well-known and established bare carbon-based electrodes. In order to confirm the validity of the CB film preparation method, the electroanalytical performance of the proposed CBFE was examined by carrying out linear sweep voltammetry of ascorbic acid (AA), anodic stripping square-wave voltammetry of Cu(II) in acidic medium, and amperometric measurements of hydrogen peroxide under flow injection conditions. The sensing characteristics of the novel carbon film electrode, demonstrated in this preliminary study, comprise: (i) a wide working potential window ranging from +1.0 to -1.3 V (depending on the solution pH), (ii) a wide applicable pH range (at least from 2 to 12), (iii) low voltammetric background (<5 {mu}A cm{sup -2}), (iv) a satisfactory linear voltammetric and amperometric response (r{sup 2} > 0.99) to various analytes, (v) good reproducibility (for example, r.s.d. of 2% in amperometric detection of H{sub 2}O{sub 2} and r.s.d. of 8.5% for electrode-to-electrode CV runs), and (vi) stable and fast current response (at least 100 CV runs with

  18. Non-adherence to prescribed home rehabilitation exercises for musculoskeletal injuries: the role of the patient-practitioner relationship.

    Science.gov (United States)

    Wright, Bradley James; Galtieri, Nicholas Justin; Fell, Michelle

    2014-02-01

    To identify which factors best explain non-adherence to home rehabilitation exercises (HRE) for patients with musculoskeletal injuries. Cross-sectional study. Participants (n = 87) aged 17-91 years completed questionnaires measuring demographic and injury-related information, self-efficacy, personality, health locus of control, patient-practitioner relationship, optimism, health value and adherence to HRE. In addition, each participant's attending physiotherapist assessed the participant's adherence and effort during the appointment. A hierarchical regression with 3 steps (step 1: disposition; step 2: cognitive factors; step 3: patient-practitioner relationship) and adherence to HRE as the dependent variable was conducted. The factors in step 3 were the most significant and explained 16% (p HRE. In addition, a high score for patient neuroticism was found to correlate with poor adherence to HRE. These preliminary results suggest that the patient-practitioner relationship is the best predictor of adherence to HRE, and that improving patient perception of the clinician's productivity, communication of information and trust during consultations may improve adherence to HRE.

  19. Statin non-adherence and residual cardiovascular risk: There is need for substantial improvement.

    Science.gov (United States)

    Banach, Maciej; Stulc, Tomas; Dent, Ricardo; Toth, Peter P

    2016-12-15

    Although statin therapy has proven to be the cornerstone for prevention and treatment of cardiovascular disease (CVD), there are many patients for whom long-term therapy remains suboptimal. The aims of this article are to review the current complex issues associated with statin use and to explore when novel treatment approaches should be considered. Statin discontinuation as well as adherence to statin therapy remain two of the greatest challenges for lipidologists. Evidence suggests that between 40 and 75% of patients discontinue their statin therapy within one year after initiation. Furthermore, whilst the reasons for persistence with statin therapy are complex, evidence shows that low-adherence to statins negatively impacts clinical outcomes and residual CV risk remains a major concern. Non-adherence or lack of persistence with long-term statin therapy in real-life may be the main cause of inadequate low density lipoprotein cholesterol lowering with statins. There is a large need for the improvement of the use of statins, which have good safety profiles and are inexpensive. On the other hand, in a non-cost-constrained environment, proprotein convertase subtilisin/kexin type 9 inhibitors should arguably be used more often in those patients in whom treatment with statins remains unsatisfactory. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. $MNO_2$ catalyzed carbon electrodes for dioxygen reduction in concentrated alkali

    OpenAIRE

    Manoharan, R; Shulka, AK

    1984-01-01

    A process to deposit $\\gamma-MnO_2$ catalytic oxide onto coconut-shell charcoal substrate is described. Current-potential curves for electroreduction of dioxygen with electrodes fabricated from this catalyzed substrate are obtained in 6M KOH under ambient conditions. The performance of these electrodes is competitive with platinized carbon electrodes.

  1. Targeting Medication Non-Adherence Behavior in Selected Autoimmune Diseases: A Systematic Approach to Digital Health Program Development.

    Directory of Open Access Journals (Sweden)

    Trevor van Mierlo

    Full Text Available 29 autoimmune diseases, including Rheumatoid Arthritis, gout, Crohn's Disease, and Systematic Lupus Erythematosus affect 7.6-9.4% of the population. While effective therapy is available, many patients do not follow treatment or use medications as directed. Digital health and Web 2.0 interventions have demonstrated much promise in increasing medication and treatment adherence, but to date many Internet tools have proven disappointing. In fact, most digital interventions continue to suffer from high attrition in patient populations, are burdensome for healthcare professionals, and have relatively short life spans.Digital health tools have traditionally centered on the transformation of existing interventions (such as diaries, trackers, stage-based or cognitive behavioral therapy programs, coupons, or symptom checklists to electronic format. Advanced digital interventions have also incorporated attributes of Web 2.0 such as social networking, text messaging, and the use of video. Despite these efforts, there has not been little measurable impact in non-adherence for illnesses that require medical interventions, and research must look to other strategies or development methodologies. As a first step in investigating the feasibility of developing such a tool, the objective of the current study is to systematically rate factors of non-adherence that have been reported in past research studies.Grounded Theory, recognized as a rigorous method that facilitates the emergence of new themes through systematic analysis, data collection and coding, was used to analyze quantitative, qualitative and mixed method studies addressing the following autoimmune diseases: Rheumatoid Arthritis, gout, Crohn's Disease, Systematic Lupus Erythematosus, and inflammatory bowel disease. Studies were only included if they contained primary data addressing the relationship with non-adherence.Out of the 27 studies, four non-modifiable and 11 modifiable risk factors were

  2. System of fabricating a flexible electrode array

    Energy Technology Data Exchange (ETDEWEB)

    Krulevitch, Peter [Pleasanton, CA; Polla, Dennis L [Roseville, MN; Maghribi, Mariam N [Davis, CA; Hamilton, Julie [Tracy, CA; Humayun, Mark S [La Canada, CA; Weiland, James D [Valencia, CA

    2012-01-28

    An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

  3. System of fabricating a flexible electrode array

    Science.gov (United States)

    Krulevitch, Peter; Polla, Dennis L.; Maghribi, Mariam N.; Hamilton, Julie; Humayun, Mark S.; Weiland, James D.

    2010-10-12

    An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

  4. Identification of patients at risk of non-adherence to oral antirheumatic drugs in rheumatoid arthritis using the Compliance Questionnaire in Rheumatology: an ARCO sub-study.

    Science.gov (United States)

    Marras, Carlos; Monteagudo, Indalecio; Salvador, Georgina; de Toro, Francisco J; Escudero, Alejandro; Alegre-Sancho, Juan J; Raya, Enrique; Ortiz, Ana; Carmona, Loreto; Mestre, Yvonne; Cea-Calvo, Luis; Calvo-Alén, Jaime

    2017-07-01

    The ARCO study (Study on Adherence of Rheumatoid Arthritis patients to SubCutaneous and Oral Drugs), a multicenter, non-interventional retrospective study, was primarily designed to assess the percentage of patients [aged ≥18 years with an established rheumatoid arthritis (RA) diagnosis] with non-adherence to prescribed subcutaneous biologicals. This paper reports data for the secondary objective from a subset of patients, namely to evaluate non-adherence to prescribed oral antirheumatic drugs in RA patients in Spain using the validated Compliance Questionnaire Rheumatology (CQR). Patients also completed the Morisky-Green Medication Adherence Questionnaire, Beliefs about Medicines Questionnaire, and a questionnaire (developed and validated in Spain) on patient satisfaction with RA treatment and preferences. A total of 271 patients (76.7% females; mean age 55.6 years) were being treated with oral drugs for RA, of which 234 completed the CQR questionnaire. Non-adherence was reported in 49/234 (20.9%) patients. The proportion of non-adherence in younger patients (aged ≤48 years; 37.5%) was double that recorded in patients aged >48 years (p = 0.006). Patients with a perception of lower efficacy also had a higher risk of non-adherence (p = 0.012). Multivariable analysis showed that younger age and male gender were independently associated with risk of non-adherence. There was only slight agreement between the CQR and Morisky-Green assessment tools (kappa coefficient = 0.186), possibly reflecting the fact that both questionnaires measure slightly different aspects of medication adherence. In conclusion, one out of five RA patients was identified as at risk for non-adherence with the CQR, and this was more frequent in younger patients and in males.

  5. Predictors of Vitamin Adherence After Bariatric Surgery.

    Science.gov (United States)

    Sunil, Supreet; Santiago, Vincent A; Gougeon, Lorraine; Warwick, Katie; Okrainec, Allan; Hawa, Raed; Sockalingam, Sanjeev

    2017-02-01

    Vitamin supplementation in bariatric aftercare is essential to prevent nutrient deficiencies; however, rates of vitamin adherence have been as low as 30 % 6 months post-surgery. Preliminary literature suggests non-adherence to prescribed treatments can be linked to demographic and psychological factors. We aimed to determine the relationship between these factors to vitamin adherence in post-bariatric surgery patients. A total of 92 bariatric patients were assessed 6 months post-surgery. Patients were administered a questionnaire collecting demographic information, psychological scores, and self-reported adherence. Nutrient deficiencies were analyzed through serum vitamin levels measured 3 and 6 months after surgery. Wilcoxon rank-sum and chi-square tests were used for analysis. Non-adherence was associated with male sex and full-time employment (p = 0.027, p = 0.015). There were no differences with respect to living situation, education level, or relationship type. Non-adherent patients did not have significantly higher scores for generalized anxiety, depressive symptoms, or avoidant behaviors. However, non-adherent patients displayed greater attachment anxiety than their adherent counterparts (p = 0.0186). Non-adherence was also associated with lower vitamin B12 levels 6 months post-surgery (p = 0.001). Male gender and full-time work have previously been shown to be associated with non-adherence. This is the first study to demonstrate that attachment anxiety is associated with poor multivitamin adherence in the post-surgical bariatric population. This result is concordant with recent literature that has demonstrated attachment anxiety is associated with poor adherence to dietary recommendations in bariatric patients 6 months postoperatively. Presurgical screening for attachment anxiety could facilitate early interventions to promote better bariatric aftercare in this group.

  6. Production of zinc pellets

    Science.gov (United States)

    Cooper, J.F.

    1996-11-26

    Uniform zinc pellets are formed for use in batteries having a stationary or moving slurry zinc particle electrode. The process involves the cathodic deposition of zinc in a finely divided morphology from battery reaction product onto a non-adhering electrode substrate. The mossy zinc is removed from the electrode substrate by the action of gravity, entrainment in a flowing electrolyte, or by mechanical action. The finely divided zinc particles are collected and pressed into pellets by a mechanical device such as an extruder, a roller and chopper, or a punch and die. The pure zinc pellets are returned to the zinc battery in a pumped slurry and have uniform size, density and reactivity. Applications include zinc-air fuel batteries, zinc-ferricyanide storage batteries, and zinc-nickel-oxide secondary batteries. 6 figs.

  7. Controlled Deposition and Alignment of Carbon Nanotubes

    Science.gov (United States)

    Smits, Jan M. (Inventor); Wincheski, Russell A. (Inventor); Patry, JoAnne L. (Inventor); Watkins, Anthony Neal (Inventor); Jordan, Jeffrey D. (Inventor)

    2012-01-01

    A carbon nanotube (CNT) attraction material is deposited on a substrate in the gap region between two electrodes on the substrate. An electric potential is applied to the two electrodes. The CNT attraction material is wetted with a solution defined by a carrier liquid having carbon nanotubes (CNTs) suspended therein. A portion of the CNTs align with the electric field and adhere to the CNT attraction material. The carrier liquid and any CNTs not adhered to the CNT attraction material are then removed.

  8. Enhancing trichloroethylene degradation using non-aromatic compounds as growth substrates.

    Science.gov (United States)

    Kim, Seungjin; Hwang, Jeongmin; Chung, Jinwook; Bae, Wookeun

    2014-06-30

    The effect of non-aromatic compounds on the trichloroethylene (TCE) degradation of toluene-oxidizing bacteria were evaluated using Burkholderia cepacia G4 that expresses toluene 2-monooxygenase and Pseudomonas putida that expresses toluene dioxygenase. TCE degradation rates for B. cepacia G4 and P. putida with toluene alone as growth substrate were 0.144 and 0.123 μg-TCE/mg-protein h, respectively. When glucose, acetate and ethanol were fed as additional growth substrates, those values increased up to 0.196, 0.418 and 0.530 μg-TCE/mg-protein h, respectively for B. cepacia G4 and 0.319, 0.219 and 0.373 μg-TCE/mg-protein h, respectively for P. putida. In particular, the addition of ethanol resulted in a high TCE degradation rate regardless of the initial concentration. The use of a non-aromatic compound as an additional substrate probably enhanced the TCE degradation because of the additional supply of NADH that is consumed in co-metabolic degradation of TCE. Also, it is expected that the addition of a non-aromatic substrate can reduce the necessary dose of toluene and, subsequently, minimize the potential competitive inhibition upon TCE co-metabolism by toluene. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Measuring and modelling the effects of systematic non-adherence to mass drug administration

    Directory of Open Access Journals (Sweden)

    Louise Dyson

    2017-03-01

    Full Text Available It is well understood that the success or failure of a mass drug administration campaign critically depends on the level of coverage achieved. To that end coverage levels are often closely scrutinised during campaigns and the response to underperforming campaigns is to attempt to improve coverage. Modelling work has indicated, however, that the quality of the coverage achieved may also have a significant impact on the outcome. If the coverage achieved is likely to miss similar people every round then this can have a serious detrimental effect on the campaign outcome. We begin by reviewing the current modelling descriptions of this effect and introduce a new modelling framework that can be used to simulate a given level of systematic non-adherence. We formalise the likelihood that people may miss several rounds of treatment using the correlation in the attendance of different rounds. Using two very simplified models of the infection of helminths and non-helminths, respectively, we demonstrate that the modelling description used and the correlation included between treatment rounds can have a profound effect on the time to elimination of disease in a population. It is therefore clear that more detailed coverage data is required to accurately predict the time to disease elimination. We review published coverage data in which individuals are asked how many previous rounds they have attended, and show how this information may be used to assess the level of systematic non-adherence. We note that while the coverages in the data found range from 40.5% to 95.5%, still the correlations found lie in a fairly narrow range (between 0.2806 and 0.5351. This indicates that the level of systematic non-adherence may be similar even in data from different years, countries, diseases and administered drugs.

  10. Intimate partner violence and HIV-positive women's non-adherence to antiretroviral medication for the purpose of prevention of mother-to-child transmission in Lusaka, Zambia.

    Science.gov (United States)

    Hampanda, Karen M

    2016-03-01

    Prevention of mother-to-child transmission (PMTCT) depends critically on HIV-positive women's adherence to antiretroviral drugs during and after pregnancy. Adherence among pregnant and breastfeeding women remains a challenge across sub-Saharan Africa. Power dynamics within couples, such as intimate partner violence, has largely been neglected in research regarding PMTCT adherence. This study aims to determine if there is a relationship between intimate partner violence and non-adherence to PMTCT. In 2014, using a verbally administered cross-sectional survey at a large public health clinic in Lusaka, Zambia, 320 HIV-positive postpartum women, who were currently married or living with a man, provided information on their drug adherence during and after pregnancy, as well as relationship dynamics. Adherence was defined as the woman reporting she took or gave to the infant at least 80% of prescribed medication doses. Experiencing intimate partner violence was associated with decreased odds of adherence to PMTCT during and after pregnancy. Different forms of violence affected PMTCT adherence differentially. Physical violence had a less pronounced effect on non-adherence than emotional and sexual violence. A dose-response relationship between intimate partner violence and non-adherence was also observed. Intimate partner violence is associated with non-adherence to PMTCT during and after pregnancy, which deserves increased attention in the effort to eliminate mother-to-child transmission of HIV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. A green synthetic strategy of nickel hexacyanoferrate nanoparticals supported on the graphene substrate and its non-enzymatic amperometric sensing application

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Zhonghua, E-mail: xzh@nwnu.edu.cn [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); He, Nan [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Rao, Honghong [College of Chemistry and Chemical Engineering, Lanzhou City University, Lanzhou, 730070 (China); Hu, Chenxian; Wang, Xiaofen; Wang, Hui; Liu, Xiuhui [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Lu, Xiaoquan, E-mail: luxq@nwnu.edu.cn [Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China)

    2017-02-28

    Highlights: • A sensitive non-enzymatic glucose sensor was explored by using a facile and green strategy. • Well dispersed and uniform NiHCF nanoparticles can be effectively produced by the introduction of electrochemical reduction graphene oxide films. • Metal hexacyanoferrate as a potential electron mediator was proposed and applied into non-enzymatic sensing. - Abstract: Rapid glucose detection is a key requirement for both diagnosis and treatment of diabetes. A facile and green strategy to achieve spherical-shaped nickel hexacyanoferrate (NiHCF) nanoparticals supported on electrochemical reduction graphene oxide by using electrochemical cyclic voltammetry is explored. As a sensing substrate, electrochemical reduction graphene oxide deposited on a glassy carbon electrode surface exhibited obvious positive effect on the electrodeposition of NiHCF nanoparticals with spherical structure and thus effectively improved the electrical conductivity and electrochemical sensing of the proposed amperometric sensor. Proof-concept experiments demonstrated that the proposed nanocomposites modified electrode exhibited excellent sensitivity toward glucose oxidation as well as with a satisfying detection limit of 0.11 μM. More importantly, we also explore that as a simple, green and facile method, electrochemical technology can be employed and provide a new strategy for developing GO and metal hexacyanoferrate based amperometric sensing platform toward glucose and other biomolecules.

  12. A green synthetic strategy of nickel hexacyanoferrate nanoparticals supported on the graphene substrate and its non-enzymatic amperometric sensing application

    International Nuclear Information System (INIS)

    Xue, Zhonghua; He, Nan; Rao, Honghong; Hu, Chenxian; Wang, Xiaofen; Wang, Hui; Liu, Xiuhui; Lu, Xiaoquan

    2017-01-01

    Highlights: • A sensitive non-enzymatic glucose sensor was explored by using a facile and green strategy. • Well dispersed and uniform NiHCF nanoparticles can be effectively produced by the introduction of electrochemical reduction graphene oxide films. • Metal hexacyanoferrate as a potential electron mediator was proposed and applied into non-enzymatic sensing. - Abstract: Rapid glucose detection is a key requirement for both diagnosis and treatment of diabetes. A facile and green strategy to achieve spherical-shaped nickel hexacyanoferrate (NiHCF) nanoparticals supported on electrochemical reduction graphene oxide by using electrochemical cyclic voltammetry is explored. As a sensing substrate, electrochemical reduction graphene oxide deposited on a glassy carbon electrode surface exhibited obvious positive effect on the electrodeposition of NiHCF nanoparticals with spherical structure and thus effectively improved the electrical conductivity and electrochemical sensing of the proposed amperometric sensor. Proof-concept experiments demonstrated that the proposed nanocomposites modified electrode exhibited excellent sensitivity toward glucose oxidation as well as with a satisfying detection limit of 0.11 μM. More importantly, we also explore that as a simple, green and facile method, electrochemical technology can be employed and provide a new strategy for developing GO and metal hexacyanoferrate based amperometric sensing platform toward glucose and other biomolecules.

  13. Depression longitudinally mediates the association of appearance concerns to ART non-adherence in HIV-infected individuals with a history of injection drug use.

    Science.gov (United States)

    Blashill, Aaron J; Gordon, Janna R; Safren, Steven A

    2014-02-01

    Appearance concerns are common among HIV-infected individuals, and previous cross-sectional and longitudinal data indicate that these concerns are associated with antiretroviral therapy (ART) non-adherence. However, to date, no known prospective data have explored the mechanism behind this relationship. Thus, the aim of the current study was to test depression severity as a prospective mediator of the relationship between appearance concerns and ART non-adherence in HIV-infected individuals with a history of injection drug use (IDU). Participants were 89 HIV-infected individuals with a history of IDU who participated in a prospective, randomized controlled trial of cognitive behavioral therapy for depression and medication adherence. Clinician-administered measures of depression severity and appearance concerns, along with electronic monitoring of ART non-adherence were included. Data were analyzed using longitudinal linear mixed-level modeling, and mediation was tested via the Monte Carlo Method of Assessing Mediation. Appearance concerns were predictive of depression severity, γ = .31, SE = .076, 95 % CI [.16, .46], t = 4.1, p = .0001, and depression severity was predictive of ART non-adherence, γ = 3.3, SE = 1.3, 95 % CI [.8, 5.8], t = 2.6, p = .01. The effect of appearance concerns on ART non-adherence, however, was significantly mediated by depression severity, γ = 1.02, 95 % CI [.21, 2.1]. Appearance concerns are associated with depression severity, which in turn is associated with ART non-adherence. Integrative interventions addressing appearance concerns, depression and ART adherence are needed, as this is one potential pathway towards worse health outcomes in HIV-infected individuals.

  14. Gene transfer device utilizing micron-spiked electrodes produced by the self-organization phenomenon of Fe-alloy.

    Science.gov (United States)

    Miyano, Naoki; Inoue, Yuuki; Teramura, Yuji; Fujii, Keisuke; Tsumori, Fujio; Iwata, Hiroo; Kotera, Hidetoshi

    2008-07-01

    In the diffusional phase transformation of two-phase alloys, the new phase precipitates form the matrix phase at specific temperatures, followed by the formation of a mixed microstructure comprising the precipitate and the matrix. It has been found that by specific chemical-etching treatment, the precipitate in Fe-25Cr-6Ni alloy projects substantially and clusters at the surface. The configuration of the precipitate has an extremely high aspect ratio: it is several microns in width and several tens of microns in length (known as micron-spiked). This study targets the development of a gene transfer device with a micro-spike produced based on the self-organization phenomenon of the Fe-25Cr-6Ni alloy. With this spike-projected device, we tried to efficiently transfer plasmid DNA into adherent cells by electric pulse-triggered gene transfer using a plasmid-loaded electrode (electroporation-based reverse transfection). The spiked structure was applied to a substrate of the device to allow efficient gene transfer into adherent cells, although the general substrate was flat and had a smooth surface. The results suggest that this unique spike-projected device has potential applications in gene transfer devices for the analysis of the human genome in the post-genome period.

  15. Risk factors for non-adherence to cART in immigrants with HIV living in the Netherlands: Results from the Rotterdam ADherence (ROAD) project

    NARCIS (Netherlands)

    S.K. Been; D.A.M.C. van de Vijver (David); P.T. Nieuwkerk (Pythia); Brito, I. (Inês); J. Stutterheim (Janine); A.E.R. Bos (Arjan); M.E.G. Wolfers (Mireille); K. Pogány (Katalin); A. Verbon (Annelies)

    2016-01-01

    textabstractIn the Netherlands, immigrant people living with HIV (PLWH) have poorer psychological and treatment outcomes than Dutch PLWH. This cross-sectional field study examined risk factors for non-adherence to combination Antiretroviral Therapy (cART) among immigrant PLWH. First and second

  16. Risk Factors for Non-Adherence to cART in Immigrants with HIV Living in the Netherlands: Results from the ROtterdam ADherence (ROAD) Project

    NARCIS (Netherlands)

    Been, Sabrina K.; van de Vijver, David A. M. C.; Nieuwkerk, Pythia T.; Brito, Inês; Stutterheim, Sarah E.; Bos, Arjan E. R.; Wolfers, Mireille E. G.; Pogány, Katalin; Verbon, Annelies

    2016-01-01

    In the Netherlands, immigrant people living with HIV (PLWH) have poorer psychological and treatment outcomes than Dutch PLWH. This cross-sectional field study examined risk factors for non-adherence to combination Antiretroviral Therapy (cART) among immigrant PLWH. First and second generation

  17. Treatment non-adherence among patients with poorly controlled ...

    African Journals Online (AJOL)

    2014-03-01

    Mar 1, 2014 ... Background: Poor adherence to prescribed therapy among patients with chronic diseases is a growing concern which un- dermines the ... consent was obtained from individual patient to signi- .... and SRMAS in binary categories of adherence versus ..... United Kingdom Prospective Diabetes Study Group.

  18. Recyclable organic solar cells on substrates comprising cellulose nanocrystals (CNC)

    Science.gov (United States)

    Kippelen, Bernard; Fuentes-Hernandez, Canek; Zhou, Yinhua; Moon, Robert; Youngblood, Jeffrey P

    2015-12-01

    Recyclable organic solar cells are disclosed herein. Systems and methods are further disclosed for producing, improving performance, and for recycling the solar cells. In certain example embodiments, the recyclable organic solar cells disclosed herein include: a first electrode; a second electrode; a photoactive layer disposed between the first electrode and the second electrode; an interlayer comprising a Lewis basic oligomer or polymer disposed between the photoactive layer and at least a portion of the first electrode or the second electrode; and a substrate disposed adjacent to the first electrode or the second electrode. The interlayer reduces the work function associated with the first or second electrode. In certain example embodiments, the substrate comprises cellulose nanocrystals that can be recycled. In certain example embodiments, one or more of the first electrode, the photoactive layer, and the second electrode may be applied by a film transfer lamination method.

  19. Influence of substrates on photoelectrochemical performance of sprayed n-CdIn{sub 2}S{sub 4} electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Sawant, R.R.; Shinde, S.S.; Bhosale, C.H.; Rajpure, K.Y. [Electrochemical Materials Laboratory, Department of Physics, Shivaji University, Kolhapur 416 004 (India)

    2010-07-15

    Cadmium indium sulphide (CdIn{sub 2}S{sub 4}) electrodes have been prepared onto the preheated fluorine doped tin oxide (FTO) coated glass and stainless steel (SS) substrates at optimized deposition conditions by using spray pyrolysis. Influence of substrates on the photoelectrochemical (PEC) performance has been carried out using cell configuration n-CdIn{sub 2}S{sub 4}/1 M (NaOH + Na{sub 2}S + S)/C for studying the current-voltage (I-V), photovoltaic output, photovoltaic rise and decay, photo and spectral responses and capacitance-voltage (C-V) characteristics. The junction ideality factor in dark (n{sub D}) and light (n{sub L}), series and shunt resistances (R{sub s} and R{sub sh}), fill factor (FF) and efficiency ({eta}) for the cell have been estimated. The measured fill factor (FF) and cell efficiency ({eta}) of the cells are found to be 0.47%, 0.38%, and 1.06%, 0.38% for FTO and SS substrates respectively. The Energy band diagram of band bending has been constructed using the physical parameters estimated from Mott-Schottky plots. Mott-Schottky plots shows the flat-band potential (V{sub fb}) of CdIn{sub 2}S{sub 4} films to be -1.15 V/SCE and -0.90 V/SCE on FTO and SS substrates respectively. (author)

  20. [Predictors of medication non-adherence among a Moroccan sample of patients with schizophrenia: A cross sectional study].

    Science.gov (United States)

    El Ammouri, A; Kisra, H

    2017-12-01

    Schizophrenia is a chronic, relapsing, mental disorder, and lack of adherence is a common and severe problem in such patients leadingto global and heavy consequences for patients (relapses, hospitalizations, impaired quality of life…), for the family and for society. Improved understanding of the underlying reasons will help to form intervention strategies relevant to the context. We aimed to assess medication adherence among stable patients suffering from schizophrenia and to identify factors associated with non-adherence. This is a retrospective cohort study of outpatients with schizophrenia at the psychiatric hospital Ar-razi of Salé (Maroc). The patients were aged over 18, clinically stabilized under the same treatment during the three months prior to inclusion. Data (demographic, clinical and therapeutic) was collected by a questionnaire developed for this purpose. Assessment of adherence and awareness of the disorder (insight) were performed respectively by two validated scales: Medication Adherence Rating Scale the (MARS) and scale Q8. Fourty percent of schizophrenic patients included in our study were not compliant to treatment. Compared to adherent patients, non-adherent patients had history of substance use (57.6 % vs. 42.4 %, P<0.05), were less aware of their disorder (77.8 % vs. 22.2 %, P<0.01), had significantly more drug intake per day (2.4 vs. 1.9, P<0.01), took significantly more tablets per day (2.8 vs. 2.2; P<0.05) and complained of significantly more side effects (43.2 vs. 56.8, P<0.05). A logistic regression model had shown that only side effects, lack of insight, and a history of substances use are significant predictors of poor adherence in patients with schizophrenia. The results of this work should guide our efforts to improve adherence in patients with schizophrenia. Waiting for new drugs with fewer side effects and better benefit/risk, some strategies would help to improve adherence to treatment. For example: implementation of

  1. Integration of conducting polymer network in non-conductive polymer substrates

    DEFF Research Database (Denmark)

    Hansen, Thomas Steen; West, Keld; Hassager, Ole

    2006-01-01

    Anew method for integration ofconjugated, inherently conducting polymers into non-conductive polymer substrates has been developed. Alayer of the conducting polymer is polymerised by chemical oxidation, e.g. using Fe(ID) p-toluene sulfonate (ferri tosylate) followed by washing with a solvent which...... simultaneously removes residual and spent oxidant and at the same time dissolves the top layer of the polymer substrate. This results in an integration of the conducting polymer into the surface layers of the polymer substrate. Several combinations of conducting polymers and substrates have been tested...... absorption during sequential reactive ion etching has allowed for analysis of the PEDOT distribution within the surface layer of thePMMA substrate. The surface resistance ofthe conducting polymer layer remains low while the surface layer at the same time adapts some of the mechanical properties...

  2. Medication adherence beliefs of U.S community pharmacists.

    Science.gov (United States)

    Witry, Matthew J

    2018-05-01

    There is increasing attention on the role of community pharmacists in improving medication adherence. There is a need to better understand pharmacist attitudes and experiences related to this role. To assess community pharmacist perceptions of patient reasons for non-adherence, characterize the adherence beliefs of community pharmacists, and test if there are demographic predictors of pharmacists' self-efficacy, outcome expectations, and role beliefs related to intervening on medication non-adherence. A cross-sectional survey was mailed using a 4-contact approach to 1000 pharmacists practicing in 5 Midwestern U.S. States. The survey included seven domains to address the study objectives. Descriptive statistics were calculated for demographic items, coefficient alphas tested the internal consistency of scales, and multiple regression was used to test the relationship between demographics and scale means. There were 261 usable responses giving a 29% response rate. Pharmacists perceived forgetting and instructions changing without a new prescription to be the most common reasons for late refills. A minority of pharmacists agreed that non-adherence involves a deliberate decision or that negative medication beliefs were common reasons for late refills. Pharmacists were confident, had positive outcome expectations, and positive role beliefs related to interacting with patients who have adherence issues. Barriers to adherence intervention included difficulties with follow-up and documentation. Also, over half of the pharmacists reported that discussing adherence makes patients defensive. Pharmacists had positive attitudes toward intervening on medication non-adherence although barriers to intervention are present. Pharmacists perceived non-intentional reasons for late refills to be more prevalent than intentional reasons. Pharmacists may benefit from additional non-adherence communication training and support targeted at identifying a broader range of non-adherence

  3. Medication adherence in inflammatory bowel disease

    Directory of Open Access Journals (Sweden)

    Webber Chan

    2017-10-01

    Full Text Available Inflammatory bowel disease (IBD is a chronic idiopathic inflammatory condition with intestinal and extraintestinal manifestations. Medications are the cornerstone of treatment of IBD. However, patients often adhere to medication poorly. Adherence to medications is defined as the process by which patients take their medications as prescribed. Treatment non-adherence is a common problem among chronic diseases, averaging 50% in developed countries and is even poorer in developing countries. In this review, we will examine the adherence data in IBD which vary greatly depending on the study population, route of administration, and methods of adherence measurement used. We will also discuss the adverse clinical outcomes related to non-adherence to medical treatment including increased disease activity, flares, loss of response to anti-tumor necrosis factor therapy, and so forth. There are many methods to measure medication adherence namely direct and indirect methods, each with their advantages and drawbacks. Finally, we will explore different intervention strategies to improve adherence to medications.

  4. Characterization of Platinum Electrodes and In-situ Cell Confluency Measurement Based on Current Changes of Cell-Electrodes

    Directory of Open Access Journals (Sweden)

    Chin Fhong SOON

    2015-04-01

    Full Text Available This study aimed at the development of a biosensor to examine the growth confluency of human derived keratinocytes (HaCaT cell lines in-situ. The biosensor consists of a sputter- coated glass substrate with platinum patterns. Cells were grown on the conductive substrates and the confluency of the cells were monitored in-situ based on the conductivity changes of the substrates. Characterization of the cell proliferation and confluency were interrogated using electrical cell-substrate impedance sensing (ECIS techniques and current change of cells using a pico-ammeter. The investigation was followed by the electrical characterization of the platinum electrode (PE using a two probe I-V measurement system. The surface morphology of platinum electrodes were studied using an atomic force microscopy (AFM and the HaCaT cell morphology was studied using Field-Emission Scanning Electron Microscopy (FE-SEM. The microscopy results showed that the cells coupled and proliferated on the platinum electrodes. For monitoring the conductivity and impedance changes of the cell-electrode in-situ, the cover of a Petri dish was inserted with pogo pins to be in contact with the platinum electrodes. The impedance was sampled using the ECIS technique at a twenty-four hour interval. In our findings, the cell proliferation rate can be measured by observing the changes in capacitance or impedance measured at low ac frequencies ranged from 10 - 1 kHz. In good agreement, the current measured at micro-ampere range by the biosensor decreased as the cell coverage area increased over the time. Thus, the percent of cell confluence was shown inversely proportional to the current changes.

  5. Skipping one or more dialysis sessions significantly increases mortality: measuring the impact of non-adherence

    Directory of Open Access Journals (Sweden)

    Eduardo Gottlieb

    2014-06-01

    Full Text Available Introduction: Non-adherence to the prescribed dialysis sessions frequency ranges from 2% to 50% of patients. The objective of this study was to evaluate the impact of detecting and measuring the non-adherence to the prescribed dialysis frequency and to determine the importance of a multidisciplinary approach with the aim of improving adherence. Methods: longitudinal cohort study including 8,164 prevalent hemodialysis patients in April 2010, with more than 90 days of treatment, in Fresenius Medical Care Argentina units that were monitored for 3 years. The survey evaluated: interruption of at least one dialysis session in a month or reduction at least 10 minutes of a dialysis session in a month, during 6 months prior to the survey. Relative mortality risks were evaluated among groups. Results: 648 patients (7.9% interrupted dialysis sessions: 320 (3.9% interrupted one session per month and 328 (4.01% interrupted more than one session per month. After 3 years monitoring, 349 patients (53.8 % remained active in hemodialysis and 299 were inactive due to different reasons: 206 deceased (31.8 %, 47 transfers or monitoring losses (7.25 %, 36 transplanted (5.55 %, 8 changes to PD modality (1.2% and 2 recovered their kidney function (0.3 %.Interrupting one session per month significantly increased the mortality risk comparing both groups (interrupters and non-interrupters: RR 2.65 (IC 95% 2.24 – 3.14. Interrupting more than one dialysis session also increased significantly mortality risk comparing to the non-interrupters: RR 2.8 (IC 95% 2.39 – 3.28. After 3 years monitoring, 41.6 % of interrupters at the beginning had improved their adherence through a multidisciplinary program of quality improvement. Conclusion: Global mortality was greater among patients who interrupted dialysis sessions. A considerable proportion of interrupter patients at the beginning modified their behavior through the implementation of a multidisciplinary program of quality

  6. Attitudes towards medication non-adherence in elderly kidney transplant patients: A Q methodology study

    NARCIS (Netherlands)

    M. Moors-Tielen (Mirjam); N.J.A. van Exel (Job); M.C. Buren; L. Maasdam; W. Weimar (Willem)

    2011-01-01

    textabstractBackground. Non-adherence to the post-transplant regime is a common problem in kidney transplant patients and may lead to rejection or even graft failure. This study investigated attitudes towards the post-transplant regime of immunosuppressive medication among the ever growing

  7. All-carbon multi-electrode array for real-time in vitro measurements of oxidizable neurotransmitters

    Science.gov (United States)

    Picollo, Federico; Battiato, Alfio; Bernardi, Ettore; Plaitano, Marilena; Franchino, Claudio; Gosso, Sara; Pasquarelli, Alberto; Carbone, Emilio; Olivero, Paolo; Carabelli, Valentina

    2016-02-01

    We report on the ion beam fabrication of all-carbon multi electrode arrays (MEAs) based on 16 graphitic micro-channels embedded in single-crystal diamond (SCD) substrates. The fabricated SCD-MEAs are systematically employed for the in vitro simultaneous amperometric detection of the secretory activity from populations of chromaffin cells, demonstrating a new sensing approach with respect to standard techniques. The biochemical stability and biocompatibility of the SCD-based device combined with the parallel recording of multi-electrodes array allow: i) a significant time saving in data collection during drug screening and/or pharmacological tests over a large number of cells, ii) the possibility of comparing altered cell functionality among cell populations, and iii) the repeatition of acquisition runs over many cycles with a fully non-toxic and chemically robust bio-sensitive substrate.

  8. Uncharged positive electrode composition

    Science.gov (United States)

    Kaun, Thomas D.; Vissers, Donald R.; Shimotake, Hiroshi

    1977-03-08

    An uncharged positive-electrode composition contains particulate lithium sulfide, another alkali metal or alkaline earth metal compound other than sulfide, e.g., lithium carbide, and a transition metal powder. The composition along with a binder, such as electrolytic salt or a thermosetting resin is applied onto an electrically conductive substrate to form a plaque. The plaque is assembled as a positive electrode within an electrochemical cell opposite to a negative electrode containing a material such as aluminum or silicon for alloying with lithium. During charging, lithium alloy is formed within the negative electrode and transition metal sulfide such as iron sulfide is produced within the positive electrode. Excess negative electrode capacity over that from the transition metal sulfide is provided due to the electrochemical reaction of the other than sulfide alkali metal or alkaline earth metal compound.

  9. Sharia Adherence Mosque Survey: Correlations between Sharia Adherence and Violent Dogma in U.S. Mosques

    Directory of Open Access Journals (Sweden)

    Mordechai Kedar

    2011-12-01

    Full Text Available A random survey of 100 representative mosques in the U.S. was conducted to measure the correlation between Sharia adherence and dogma calling for violence against non-believers.  Of the 100 mosques surveyed, 51% had texts on site rated as severely advocating violence; 30% had texts rated as moderately advocating violence; and 19% had no violent texts at all.  Mosques that presented as Sharia adherent were more likely to feature violence-positive texts on site than were their non-Sharia-adherent counterparts.  In 84.5% of the mosques, the imam recommended studying violence-positive texts.  The leadership at Sharia-adherent mosques was more likely to recommend that a worshipper study violence-positive texts than leadership at non-Sharia-adherent mosques.  Fifty-eight percent of the mosques invited guest imams known to promote violent jihad.  The leadership of mosques that featured violence-positive literature was more likely to invite guest imams who were known to promote violent jihad than was the leadership of mosques that did not feature violence-positive literature on mosque premises.  

  10. Electromechanical properties of indium–tin–oxide/poly(3,4-ethylenedioxythiophene): Poly(styrenesulfonate) hybrid electrodes for flexible transparent electrodes

    International Nuclear Information System (INIS)

    Jung, Sunghoon; Lim, Kyounga; Kang, Jae-Wook; Kim, Jong-Kuk; Oh, Se-In; Eun, Kyoungtae; Kim, Do-Geun; Choa, Sung-Hoon

    2014-01-01

    We investigated an indium–tin–oxide (ITO)/poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) hybrid electrode as a potential flexible and transparent electrode. In particular, the mechanical integrity of an ITO/PEDOT:PSS hybrid electrode deposited onto a polyethylene terephthalate (PET) substrate was investigated via outer/inner bending, twisting, stretching, and adhesion tests. A PEDOT:PSS layer was inserted between ITO and PET substrate as a buffer layer to improve the flexibility and electrical properties. When a PEDOT:PSS layer was inserted, the sheet resistance of the 20 nm-thick ITO film decreased from 270 Ω/square to 57 Ω/square. Notably, the ITO/PEDOT:PSS hybrid electrode had a constant resistance change (ΔR/R 0 ) within an outer and inner bending radius of 3 mm. The bending fatigue test showed that the ITO/PEDOT:PSS hybrid electrode can withstand 10,000 bending cycles. Furthermore, the stretched ITO/PEDOT:PSS hybrid electrode showed a fairly constant resistance change up to 4%, which is more stable than the resistance change of the ITO electrode. The ITO/PEDOT:PSS electrode also shows good adhesion strength. The superior flexibility of the ITO/PEDOT:PSS hybrid electrode is attributed to the existence of a flexible PEDOT:PSS layer. This indicates that the hybridization of an ITO and PEDOT:PSS layer is a promising electrode scheme for next-generation flexible transparent electrodes. - Highlights: • We propose a hybrid electrode for flexible electronics. • Electrode made from In 2 O 3 :SnO 2 /poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) • PEDOT:PSS as a buffer layer increases flexibility and electrical conductivity. • Hybrid electrode has a superior flexibility. • Hybrid electrode can be a promising flexible transparent electrode scheme

  11. Coated carbon nanotube array electrodes

    Science.gov (United States)

    Ren, Zhifeng [Newton, MA; Wen, Jian [Newton, MA; Chen, Jinghua [Chestnut Hill, MA; Huang, Zhongping [Belmont, MA; Wang, Dezhi [Wellesley, MA

    2008-10-28

    The present invention provides conductive carbon nanotube (CNT) electrode materials comprising aligned CNT substrates coated with an electrically conducting polymer, and the fabrication of electrodes for use in high performance electrical energy storage devices. In particular, the present invention provides conductive CNTs electrode material whose electrical properties render them especially suitable for use in high efficiency rechargeable batteries. The present invention also provides methods for obtaining surface modified conductive CNT electrode materials comprising an array of individual linear, aligned CNTs having a uniform surface coating of an electrically conductive polymer such as polypyrrole, and their use in electrical energy storage devices.

  12. Studies of pyrrole black electrodes as possible battery positive electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Mengoli, G.; Musiani, M.M.; Fleischmann, M.; Pletcher, D.

    1984-05-01

    It is shown that a polypyrrole, pyrrole black, may be formed anodically in several aqueous acids. The polypyrrole film shows a redox couple at less positive potentials than that required to form the film and the charge associated with these reduction and oxidation processes together with their stabilty to cycling varies with the anion in solution and the potential where the polypyrrole is formed; over-oxidation of the film caused by taking its potential too positive has a particularly disadvantageous affect. In the acids HBr and HI, the polypyrrole films can act as a storage medium for Br/sub 2/ or I/sub 2/ so that they may be used as a substrate for a X/sub 2//X/sup -/ electrode. Such electrodes may be charge/discharge cycled and the pyrrole/Br/sub 2/ electrode shows promise as a battery positive electrode.

  13. Mechanical Characterization of Polydopamine-Assisted Silver Deposition on Polymer Substrates

    Science.gov (United States)

    Cordes, Amanda Laurence

    Inspired by the adhesive proteins in marine mussels, polydopamine has become a popular adhesive ad-layer for surface functionalization of a variety of substrates. Based on the chemistry of the dopamine monomer, amine and thiol functional groups are hypothesized to increase adhesion between polymer substrates and polydopamine thin films. This hypothesis was the central motivation for development of a tailorable thiol-ene system in order to study the effects of substrate chemistry on polydopamine adhesion. While polydopamine-adhered silver has been studied on a variety of substrates, no in depth mechanical characterization has been performed and to date, no research has been published on thiol-enes coated in polydopamine-adhered silver. The purpose of this study was to characterize the mechanical durability and adhesion properties of a polydopamine-adhered silver film on commercial substrates and a tailorable thiol-ene system. Polydopamine and silver coatings were deposited on a variety of polymer substrates through a simple dip-coat process. The polydopamine forms a thin uniform adhesive layer and the silver deposits in a discontinuous manner with a nanoparticle sized base layer covering the full surface and micron-sized clusters adhered sporadically on top. Mechanical tensile testing was performed to characterize the durability of the silver coating on commercial polymers. Coated nylon and HDPE showed no signs of degradation or delamination of the polydopamine-adhered silver coating up to 30% strain although both substrates showed large plastic deformation. Peel tests were performed on both commercial polymers as well as a tailorable thiol-ene system. Results support the hypothesis that polydopamine adhesion is increased with the presence of functional groups. Parts of the HDPE sample were cleanly peeled, but silver patches were left sporadically across the surface pointing to weaker adhesion between polyethylene and polydopamine. A high adhesive strength tape was

  14. Alternate electrode materials for the SP100 reactor

    International Nuclear Information System (INIS)

    Randich, E.

    1992-05-01

    This work was performed in response to a request by the Astro-Space Division of the General Electric Co. to develop alternate electrodes materials for the electrodes of the PD2 modules to be used in the SP100 thermoelectric power conversion system. Initially, the project consisted of four tasks: (1) development of a ZrB 2 (C) CVD coating on SiMo substrates, (2) development of a ZrB 2 (C) CVD coating on SiGe substrates, (3) development of CVI W for porous graphite electrodes, and (4) technology transfer of pertinent developed processes. The project evolved initially into developing only ZrB 2 coatings on SiGe and graphite substrates, and later into developing ZrB 2 coatings only on graphite substrates. Several sizes of graphite and pyrolytic carbon-coated graphite substrates were coated with ZrB 2 during the project. For budgetary reasons, the project was terminated after half the allotted time had passed. Apart from the production of coated specimens for evaluation, the major accomplishment of the project was the development of the CVD processing to produce the desired coatings

  15. The Joule heating problem in silver nanowire transparent electrodes

    Science.gov (United States)

    Khaligh, H. H.; Xu, L.; Khosropour, A.; Madeira, A.; Romano, M.; Pradére, C.; Tréguer-Delapierre, M.; Servant, L.; Pope, M. A.; Goldthorpe, I. A.

    2017-10-01

    Silver nanowire transparent electrodes have shown considerable potential to replace conventional transparent conductive materials. However, in this report we show that Joule heating is a unique and serious problem with these electrodes. When conducting current densities encountered in organic solar cells, the average surface temperature of indium tin oxide (ITO) and silver nanowire electrodes, both with sheet resistances of 60 ohms/square, remains below 35 °C. However, in contrast to ITO, the temperature in the nanowire electrode is very non-uniform, with some localized points reaching temperatures above 250 °C. These hotspots accelerate nanowire degradation, leading to electrode failure after 5 days of continuous current flow. We show that graphene, a commonly used passivation layer for these electrodes, slows nanowire degradation and creates a more uniform surface temperature under current flow. However, the graphene does not prevent Joule heating in the nanowires and local points of high temperature ultimately shift the failure mechanism from nanowire degradation to melting of the underlying plastic substrate. In this paper, surface temperature mapping, lifetime testing under current flow, post-mortem analysis, and modelling illuminate the behaviour and failure mechanisms of nanowires under extended current flow and provide guidelines for managing Joule heating.

  16. Attitudes towards medication non-adherence in elderly kidney transplant patients: A Q methodology study

    OpenAIRE

    Moors-Tielen, Mirjam; Exel, Job; Buren, M.C.; Maasdam, L.; Weimar, Willem

    2011-01-01

    textabstractBackground. Non-adherence to the post-transplant regime is a common problem in kidney transplant patients and may lead to rejection or even graft failure. This study investigated attitudes towards the post-transplant regime of immunosuppressive medication among the ever growing population of elderly kidney recipients.Methods. Q methodology was used to explore attitude profiles. Participants (> 65 years) were asked to rank-order opinion statements on issues associated with (non-)ad...

  17. A Highly Sensitive Electrochemical Glucose Sensor By Nickel-Epoxy Electrode With Non-Enzymatic Sensor

    Directory of Open Access Journals (Sweden)

    Riyanto Riyanto

    2016-03-01

    Full Text Available The preparation of new sensor for glucose was based on the fact that glucose can be determined by non-enzymatic glucose oxidase. The Ni metals (99.98% purity, 0.5 mm thick, Aldrich Chemical Company was used to prepare Ni-Epoxy electrode. The Ni-epoxy electrodes were prepared in square cut of 1 cm and 1 mm by length and wide respectively. The Ni metal electrodes were connected to silver wire with silver conducting paint prior covered with epoxy gum. The prepared of nickel-epoxy modified electrode showed outstanding electro catalytic activity toward the oxidation of glucose in alkaline solution. The result from this research are correlation of determination using Nickel-Epoxyelectrode for electroanalysis of glucose in NaOH was R2 = 0.9984. LOQ, LOD and recovery of the Nickel-Epoxy electrode towards glucose were found to be 4.4 μM, 1.48 μM and 98.19%, respectively. The Nickel-Epoxy wire based electrochemical glucose sensor demonstrates good sensitivity, wide linear range, outstanding detection limit, attractive selectivity, good reproducibility, high stability as well as prominent feasibility use of non-enzymatic sensor for monitoring glucose in human urine owing to its advantages of low cost, simple preparation and excellent properties for glucose detection.

  18. Nickel–copper hybrid electrodes self-adhered onto a silicon wafer by supersonic cold-spray

    International Nuclear Information System (INIS)

    Lee, Jong-Gun; Kim, Do-Yeon; Kang, Byungjun; Kim, Donghwan; Song, Hee-eun; Kim, Jooyoung; Jung, Woonsuk; Lee, Dukhaeng; Al-Deyab, Salem S.; James, Scott C.; Yoon, Sam S.

    2015-01-01

    High-performance electrodes are fabricated through supersonic spraying of nickel and copper particles. These electrodes yield low specific resistivities, comparable to electrodes produced by screen-printed silver paste and light-induced plating. The appeal of this fabrication method is the low cost of copper and large area scalability of supersonic spray-coating techniques. The copper and nickel electrode was fabricated in the open air without any pre- or post-treatment. The spray-coated copper–nickel electrode was characterized by optical microscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction, and energy dispersive spectroscopy. Although both SEM and TEM images confirmed voids trapped between flattened particles in the fabricated electrode, this electrode’s resistivity was order 10 −6 Ω cm, which is comparable to the bulk value for pure copper

  19. Adherence of non-pharmaceutically sponsored oncology trial protocols to the International Conference on Harmonization (ICH) guidelines in an academic institution outside the ICH jurisdictions and the impact of IRB implementation on this adherence

    International Nuclear Information System (INIS)

    Zeeneldin, A.A.

    2013-01-01

    Purpose: To assess adherence of non-pharmaceutically sponsored trials (non-PSTs) to ICH protocol structure guidelines and to estimate the effect of implementing Institutional Review Boards (IRB) review on this adherence. Methods: This is a retrospective exploratory study where 60 non-PST clinical trial protocols (CTPs) were reviewed and halved to IRB-reviewed CTPs (IRCTPs) and non-lRB-reviewed CTPs (non-lRCTPs). Adherence score (AS) was calculated as the number of fulfilled items or sub-items divided by their total number. Results: Three adherence patterns were encountered: (1) items consistently present in both groups e.g. general and background information, objectives, inclusion criteria and intervention details, (2) items consistently absent in both groups and included contact information of investigators and trial sites, product accountability, randomization codes management, interim analyses and many other statistical aspects, and (3) items variably present in both groups where the effect of IRB was verifiable. Trial site details, potential benefits, discontinuation and exclusion criteria, and follow up for adverse events were more encountered in IRCTPs than non-IRCTPs. Withdrawal criteria monitoring of treatment compliance showed a reverse pattern (p < 0.05 for all). The total AS, administrative AS and ethics AS for IRCTPs was 43%, 22% and 70% compared to 38%, 16% and 33% for non-IRCTPs (p < 0.003, <0.001, 0.004), respectively. The scientific AS was 54% for both groups (p = 0.87). Conclusions: IRB-implementation at NCl-Egypt improved ethical and administrative sections of academic protocols. However, this improvement is modest and needs further actions including adoption of protocol templates. Scientific sections were as good after IRB-implementation as they were before that

  20. Attitudes towards medication non-adherence in elderly kidney transplant patients: a Q methodology study.

    Science.gov (United States)

    Tielen, Mirjam; van Exel, N Job A; van Buren, Marleen C; Maasdam, Louise; Weimar, Willem

    2011-05-01

    Non-adherence to the post-transplant regime is a common problem in kidney transplant patients and may lead to rejection or even graft failure. This study investigated attitudes towards the post-transplant regime of immunosuppressive medication among the ever growing population of elderly kidney recipients. Q methodology was used to explore attitude profiles. Participants (> 65 years) were asked to rank-order opinion statements on issues associated with (non-)adherence. The rankings were subject to by-person factor analysis, and the resulting factors were interpreted and described as attitudes. Twenty-six elderly renal transplant recipients participated in the study. All passed the Mini-Mental State Examination. Two attitude profiles were found: (i) satisfied and easy-going (attitude A), and (ii) reserved and concerned (attitude B). Elderly patients with attitude A want to enjoy the new life following their kidney transplant, are not very concerned about having to recommence dialysis, now and then even forget their regime, and do not really worry about it. Elderly patients with attitude B feel more insecure about their kidney transplant, are fairly concerned over issues like rejection or going back on dialysis, and try to adapt their way of life to the regime. One-third of these elderly patients forget their medication at least once a month, but there was no difference between attitude groups. Attitudes about the post-transplant regime differ among elderly patients, implying different needs for assistance, monitoring and risk of non-adherence to the regime. The proportion of elderly patients who forget their medication is considerable, but may be much higher among those with mild and severe cognitive limitations.

  1. Fabrication of non-hexagonal close packed colloidal array on a substrate by transfer

    Science.gov (United States)

    Banik, Meneka; Mukherjee, Rabibrata

    Self-organized colloidal arrays find application in fabrication of solar cells with advanced light management strategies. We report a simple spincoating based approach for fabricating two dimensional colloidal crystals with hexagonal and non-hexagonal close packed assembly on flat and nanopatterned substrates. The non-HCP arrays were fabricated by spin coating the particles onto soft lithographically fabricated substrates. The substrate patterns impose directionality to the particles by confining them within the grooves. We have developed a technique by which the HCP and non-HCP arrays can be transferred to any surface. For this purpose the colloidal arrays were fabricated on a UV degradable PMMA layer, resulting in transfer of the particles on UV exposure. This allows the colloidal structures to be transported across substrates irrespective of their surface energy, wettability or morphology. Since the particles are transferred without exposing it to any kind of chemical or thermal environment, it can be utilized for placing particles on top of thin film solar cells for improving their absorption efficiency.

  2. Experimental characterization of PZT fibers using IDE electrodes

    Science.gov (United States)

    Wyckoff, Nicholas; Ben Atitallah, Hassene; Ounaies, Zoubeida

    2016-04-01

    Lead zirconate titanate (PZT) fibers are mainly used in active fiber composites (AFC) where they are embedded in a polymer matrix. Interdigitated electrodes (IDE) along the direction of the fibers are used to achieve planar actuation, hereby exploiting the d33 coefficient of PZT. When embedded in the AFC, the PZT fibers are subjected to mechanical loading as well as non-uniform electric field as a result of the IDEs. Therefore, it is important to characterize the electrical and electromechanical behavior of these fibers ex-situ using the IDE electrodes to assess the impact of nonuniform electric field on the properties of the fibers. For that reason, this work aims at quantifying the impact of IDE electrodes on the electrical and electromechanical behavior of PZT fibers, which is necessary for their successful implementation in devices like AFC. The tested fibers were purchased from Advanced Cerametrics and they have an average diameter of 250 micrometers. The IDE electrodes were screen printed on an acrylic substrate. The PZT fibers were subjected to frequency sweeps at low voltages to determine permittivity for parallel and interdigitated electrodes. The piezoelectric e33 constant is determined from electromechanical testing of PZT fibers in parallel electrodes to compare the electromechanical behavior for PZT in bulk and fiber form. The dielectric constant and e33 were found to be lower for the IDE and parallel electrodes compared to bulk but comparable to results published in literature.

  3. Preparation of Pb(Zr, Ti)O3 Thin Films on Glass Substrates

    Science.gov (United States)

    Hioki, Tsuyoshi; Akiyama, Masahiko; Ueda, Tomomasa; Onozuka, Yutaka; Hara, Yujiro; Suzuki, Kouji

    2000-09-01

    Lead-zirconate-titanate (PZT) thin films were prepared on non-alkaline glass substrates widely used in liquid crystal display (LCD) devices, by plasma-assisted magnetron RF sputtering with an immersed coil. After preparation of the PZT thin film, the glass was available for use in LCD device processing. No mutual diffusion of the elements was recognized between the glass substrate and the bottom electrode. The PZT layer had a dense film structure with rectangular and columnar grains, and only its perovskite phase was crystalline. PZT thin films on a glass substrate had leakage current densities of about 10-8 A/cm2, acceptable hysteresis loop shapes with the remanent polarization (Pr) of 45 μC/cm2 and the coercive field (Ec) of 90 kV/cm. Ferroelectric properties on a glass substrate almost conform with those on a Si-based substrate.

  4. Electrochemical studies of iron/carbonates system applied to the formation of thin layers of siderite on inert substrates; Etudes electrochimiques du systeme fer/carbonates appliquees a la formation de couches minces de siderite sur des substrats inertes

    Energy Technology Data Exchange (ETDEWEB)

    Ithurbide, A. [CEA Saclay, Dept. de Physico-Chimie (DEN/DPC/SECR/L3MR), 91 - Gif sur Yvette (France); Peulon, S. [Univ. d' Evry-val-d' Essonne, UMR 8587, CNRS, 91 - Evry (France); Mandin, Ph. [Ecole Nationale Superieure de Chimie de Paris (ENSCP), UMR 7575, 75 - Paris (France); Beaucaire, C. [CEA Saclay, Dept. de Physico-Chimie (DEN/DPC/SECR/L3MR), 91 - Gif sur Yvette (France); Chausse, A. [Univ. d' Evry-val-d' Essonne, UMR 8587, CNRS, 91 - Evry (France)

    2007-07-01

    In order to understand the complex mechanisms of the reactions occurring, a methodology is developed. It is based on the use of compounds electrodeposited under the form of thin layers and which are used then as electrodes to study their interactions with the toxic species. It is in this framework that is studied the electrodeposition of siderite on inert substrates. At first, have been studied iron electrochemical systems in carbonated solutions. These studies have been carried out with classical electrochemical methods (cyclic voltametry, amperometry) coupled to in-situ measurements: quartz microbalance, pH. Different compounds have been obtained under the form of homogeneous and adherent thin layers. The analyses of these depositions, by different ex-situ characterizations (XRD, IR, SEM, EDS..) have revealed particularly the presence of siderite. Then, the influence of several experimental parameters (substrate, potential, medium composition, temperature) on the characteristics of siderite thin layers has been studied. From these experimental results, models have been proposed. (O.M.)

  5. Liquid electrode

    Science.gov (United States)

    Ekechukwu, A.A.

    1994-07-05

    A dropping electrolyte electrode is described for use in electrochemical analysis of non-polar sample solutions, such as benzene or cyclohexane. The liquid electrode, preferably an aqueous salt solution immiscible in the sample solution, is introduced into the solution in dropwise fashion from a capillary. The electrolyte is introduced at a known rate, thus, the droplets each have the same volume and surface area. The electrode is used in making standard electrochemical measurements in order to determine properties of non-polar sample solutions. 2 figures.

  6. Perspectives on reasons for non-adherence to medication in persons with schizophrenia in Ethiopia: a qualitative study of patients, caregivers and health workers.

    Science.gov (United States)

    Teferra, Solomon; Hanlon, Charlotte; Beyero, Teferra; Jacobsson, Lars; Shibre, Teshome

    2013-06-17

    Levels of non-adherence to antipsychotic medication in persons with schizophrenia in rural African settings have been shown to be comparable to those found in high-income countries. Improved understanding of the underlying reasons will help to inform intervention strategies relevant to the context. A qualitative study was conducted among persons with schizophrenia (n = 24), their caregivers (n = 19), research field workers (n = 7) and health workers (n = 1) involved in the ongoing population-based cohort study, 'The Butajira Study on Course and Outcome of Schizophrenia and Bipolar Disorder', based in rural Ethiopia. Six focus group discussions and 9 in-depth interviews were conducted to elicit perspectives on non-adherence to antipsychotic medication. Thematic analysis was used to identify prominent perspectives. Predominant reasons for non-adherence specific to a low-income country setting included inadequate availability of food to counter appetite stimulation and the perceived strength of antipsychotic medications. The vital role of the family or other social support in the absence of a statutory social safety net was emphasised. Expectations of cure, rather than need for continuing care, were reported to contribute to non-adherence in the longer-term. Many of the factors associated with non-adherence in high-income countries were also considered important in Ethiopia, including lack of insight, failure to improve with treatment, medication side effects, substance abuse, stigma and dissatisfaction with the attitude of the care provider. This study identifies additional barriers to medication adherence faced by persons with schizophrenia in Ethiopia compared to those in high-income countries. In this era of scaling up of mental health care, greater attention to provision of social and financial assistance will potentially improve adherence and thereby enable patients to benefit more fully from medication.

  7. Selective detection and recovery of gold at tannin-immobilized non-conducting electrode.

    Science.gov (United States)

    Banu, Khaleda; Shimura, Takayoshi; Sadeghi, Saman

    2015-01-01

    A tannin-immobilized glassy carbon electrode (TIGC) was prepared via electrochemical oxidation of the naturally occurring polyphenolic mimosa tannin, which generated a non-conducting polymeric film (NCPF) on the electrode surface. The fouling of the electrode surface by the electropolymerized film was evaluated by monitoring the electrode response of ferricyanide ions as a redox marker. The NCPF was permselective to HAuCl4, and the electrochemical reduction of HAuCl4 to metallic gold at the TIGC electrode was evaluated by recording the reduction current during cyclic voltammetry measurement. In the mixed electrolyte containing HAuCl4 along with FeCl3 and/or CuCl2, the NCPF remained selective toward the electrochemical reduction of HAuCl4 into the metallic state. The chemical reduction of HAuCl4 into metallic gold was also observed when the NCPF was inserted into an acidic gold solution overnight. The adsorption capacity of Au(III) on tannin-immobilized carbon fiber was 29±1.45 mg g(-1) at 60°C. In the presence of excess Cu(II) and Fe(III), tannin-immobilized NCPF proved to be an excellent candidate for the selective detection and recovery of gold through both electrochemical and chemical processes. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Graphene-Based Electrode for a Supercapacitor

    Science.gov (United States)

    Chen, Bin (Inventor); Meyyappan, Meyya (Inventor)

    2015-01-01

    A supercapacitor electrode mechanism comprising an electrically conductive, porous substrate, having one or more metallic oxides deposited on a first surface and a chemically reduced graphene oxide deposited on a second surface, to thereby provide an electrical double layer associated with the substrate. The substrate may be carbon paper or a similar substance. The layers of the supercapacitor are optionally rolled into an approximately cylindrical structure.

  9. Titanyl phthalocyanine ambipolar thin film transistors making use of carbon nanotube electrodes

    Science.gov (United States)

    Coppedè, Nicola; Valitova, Irina; Mahvash, Farzaneh; Tarabella, Giuseppe; Ranzieri, Paolo; Iannotta, Salvatore; Santato, Clara; Martel, Richard; Cicoira, Fabio

    2014-12-01

    The capability of efficiently injecting charge carriers into organic films and finely tuning their morphology and structure is crucial to improve the performance of organic thin film transistors (OTFTs). In this work, we investigate OTFTs employing carbon nanotubes (CNTs) as the source-drain electrodes and, as the organic semiconductor, thin films of titanyl phthalocyanine (TiOPc) grown by supersonic molecular beam deposition (SuMBD). While CNT electrodes have shown an unprecedented ability to improve charge injection in OTFTs, SuMBD is an effective technique to tune film morphology and structure. Varying the substrate temperature during deposition, we were able to grow both amorphous (low substrate temperature) and polycrystalline (high substrate temperature) films of TiOPc. Regardless of the film morphology and structure, CNT electrodes led to superior charge injection and transport performance with respect to benchmark Au electrodes. Vacuum annealing of polycrystalline TiOPc films with CNT electrodes yielded ambipolar OTFTs.

  10. Involvement of flocculin in negative potential-applied ITO electrode adhesion of yeast cells

    Science.gov (United States)

    Koyama, Sumihiro; Tsubouchi, Taishi; Usui, Keiko; Uematsu, Katsuyuki; Tame, Akihiro; Nogi, Yuichi; Ohta, Yukari; Hatada, Yuji; Kato, Chiaki; Miwa, Tetsuya; Toyofuku, Takashi; Nagahama, Takehiko; Konishi, Masaaki; Nagano, Yuriko; Abe, Fumiyoshi

    2015-01-01

    The purpose of this study was to develop novel methods for attachment and cultivation of specifically positioned single yeast cells on a microelectrode surface with the application of a weak electrical potential. Saccharomyces cerevisiae diploid strains attached to an indium tin oxide/glass (ITO) electrode to which a negative potential between −0.2 and −0.4 V vs. Ag/AgCl was applied, while they did not adhere to a gallium-doped zinc oxide/glass electrode surface. The yeast cells attached to the negative potential-applied ITO electrodes showed normal cell proliferation. We found that the flocculin FLO10 gene-disrupted diploid BY4743 mutant strain (flo10Δ /flo10Δ) almost completely lost the ability to adhere to the negative potential-applied ITO electrode. Our results indicate that the mechanisms of diploid BY4743 S. cerevisiae adhesion involve interaction between the negative potential-applied ITO electrode and the Flo10 protein on the cell wall surface. A combination of micropatterning techniques of living single yeast cell on the ITO electrode and omics technologies holds potential of novel, highly parallelized, microchip-based single-cell analysis that will contribute to new screening concepts and applications. PMID:26187908

  11. Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays

    Science.gov (United States)

    Li, Mary; Sultana, Mahmooda; Hess, Larry

    2012-01-01

    Graphene is a single atomic layer of graphite. It is optically transparent and has high electron mobility, and thus has great potential to make transparent conductive electrodes. This invention contributes towards the development of graphene transparent conductive electrodes for next-generation microshutter arrays. The original design for the electrodes of the next generation of microshutters uses indium-tin-oxide (ITO) as the electrode material. ITO is widely used in NASA flight missions. The optical transparency of ITO is limited, and the material is brittle. Also, ITO has been getting more expensive in recent years. The objective of the invention is to develop a graphene transparent conductive electrode that will replace ITO. An exfoliation procedure was developed to make graphene out of graphite crystals. In addition, large areas of single-layer graphene were produced using low-pressure chemical vapor deposition (LPCVD) with high optical transparency. A special graphene transport procedure was developed for transferring graphene from copper substrates to arbitrary substrates. The concept is to grow large-size graphene sheets using the LPCVD system through chemical reaction, transfer the graphene film to a substrate, dope graphene to reduce the sheet resistance, and pattern the film to the dimension of the electrodes in the microshutter array. Graphene transparent conductive electrodes are expected to have a transparency of 97.7%. This covers the electromagnetic spectrum from UV to IR. In comparison, ITO electrodes currently used in microshutter arrays have 85% transparency in mid-IR, and suffer from dramatic transparency drop at a wavelength of near-IR or shorter. Thus, graphene also has potential application as transparent conductive electrodes for Schottky photodiodes in the UV region.

  12. Nanostructured gold and platinum electrodes on silicon structures for biosensing

    International Nuclear Information System (INIS)

    Ogurtsov, V I; Sheehan, M M

    2005-01-01

    Gold and platinum metal electrodes on Si/SiO 2 having undergone anisotropic potassium hydroxide (KOH) etch treatment are considered. This treatment etches at different rates and directions in the material resulting in creation of numerous pyramid shaped holes in the silicon substrate. This surface is used to make metal electrodes with increased electrode efficiency. The electrodes can serve as the sensors or as the sensor substrates (for surface polymer modification) and because both gold and platinum are inert they have applications for food safety biosensing. Wine, an economically significant food product, was chosen as a matrix, and impedance spectroscopy (EIS) was selected as a method of investigation of electrode behaviour. Based on results of EIS, different complexity equivalent circuits were determined by applying fitting mean square root optimisation of sensor complex impedance measurements

  13. Coating adherence in galvanized steel assessed by acoustic emission wavelet analysis

    International Nuclear Information System (INIS)

    Gallego, Antolino; Gil, Jose F.; Vico, Juan M.; Ruzzante, Jose E.; Piotrkowski, Rosa

    2005-01-01

    Coating-substrate adherence in galvanized steel is evaluated by acoustic emission wavelet analysis in scratch tests on hot-dip galvanized samples. The acoustic emission results are compared with optical and electron microscopy observations in order to understand coating features related to adherence and to establish criteria aimed at improving the manufacture process

  14. Printed optically transparent graphene cellulose electrodes

    Science.gov (United States)

    Sinar, Dogan; Knopf, George K.; Nikumb, Suwas; Andrushchenko, Anatoly

    2016-02-01

    Optically transparent electrodes are a key component in variety of products including bioelectronics, touch screens, flexible displays, low emissivity windows, and photovoltaic cells. Although highly conductive indium tin oxide (ITO) films are often used in these electrode applications, the raw material is very expensive and the electrodes often fracture when mechanically stressed. An alternative low-cost material for inkjet printing transparent electrodes on glass and flexible polymer substrates is described in this paper. The water based ink is created by using a hydrophilic cellulose derivative, carboxymethyl cellulose (CMC), to help suspend the naturally hydrophobic graphene (G) sheets in a solvent composed of 70% DI water and 30% 2-butoxyethanol. The CMC chain has hydrophobic and hydrophilic functional sites which allow adsorption on G sheets and, therefore, permit the graphene to be stabilized in water by electrostatic and steric forces. Once deposited on the functionalized substrate the electrical conductivity of the printed films can be "tuned" by decomposing the cellulose stabilizer using thermal reduction. The entire electrode can be thermally reduced in an oven or portions of the electrode thermally modified using a laser annealing process. The thermal process can reduce the sheet resistance of G-CMC films to < 100 Ω/sq. Experimental studies show that the optical transmittance and sheet resistance of the G-CMC conductive electrode is a dependent on the film thickness (ie. superimposed printed layers). The printed electrodes have also been doped with AuCl3 to increase electrical conductivity without significantly increasing film thickness and, thereby, maintain high optical transparency.

  15. Electrode interface controlled electrical properties in epitaxial Pb(Zr{sub 0.52}Ti{sub 0.48})O{sub 3} films grown on Si substrates with SrTiO{sub 3} buffer layer

    Energy Technology Data Exchange (ETDEWEB)

    Boni, Andra Georgia, E-mail: andra.boni@infim.ro [National Institute of Materials Physics, Atomistilor 105bis, Magurele, Ilfov 77125 (Romania); University of Bucharest, Faculty of Physics, Magurele 077125 (Romania); Chirila, Cristina; Pasuk, Iuliana; Negrea, Raluca; Trupina, Lucian [National Institute of Materials Physics, Atomistilor 105bis, Magurele, Ilfov 77125 (Romania); Le Rhun, Gwenael [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France); Vilquin, Bertrand [Université de Lyon, Ecole Centrale de Lyon, INL, CNRS UMR5270, 36 avenue Guy de Collongue, F-69134 Ecully cedex (France); Pintilie, Ioana; Pintilie, Lucian [National Institute of Materials Physics, Atomistilor 105bis, Magurele, Ilfov 77125 (Romania)

    2015-10-30

    Electrical properties of ferroelectric capacitors based on PbZr{sub 0.52}Ti{sub 0.48}O{sub 3} thin films grown by pulsed laser deposition on silicon substrate with SrTiO{sub 3} buffer layer grown by molecular beam epitaxy were studied. A SrRuO{sub 3} layer was deposited as bottom electrode also by pulse laser deposition and Pt, Ir, Ru, SrRuO{sub 3} were used as top contacts. Electrical characterization comprised hysteresis and capacitance–voltage measurements in the temperature range from 150 K to 400 K. It was found that the macroscopic electrical properties are affected by the electrode interface, by the choice of the top electrode. However, even for metals with very different work functions (e.g. Pt and SrRuO{sub 3}) the properties of the top and bottom electrode interfaces remain fairly symmetric suggesting a strong influence from the bound polarization charges located near the interface. - Highlights: • Ferroelectric capacitors based on PbZr{sub 0.52}Ti{sub 0.48}O{sub 3} were deposited on Si substrate. • The structural characterization proved the epitaxial growth of the layers. • Macroscopic electrical properties are affected by the choice of the top electrode. • The difference on imprint field, dielectric constant are analyzed depending on the electrode-ferroelectric interface.

  16. Strategies for the fabrication of porous platinum electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Kloke, Arne; Stetten, Felix von; Kerzenmacher, Sven [Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg (Germany); Zengerle, Roland [Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg (Germany); BIOSS Centre for Biological Signalling Studies, Albert-Ludwigs-Universitaet Freiburg (Germany)

    2011-11-16

    Porous platinum is of high technological importance due to its various applications in fuel cells, sensors, stimulation electrodes, mechanical actuators and catalysis in general. Based on a discussion of the general principles behind the reduction of platinum salts and corresponding deposition processes this article discusses techniques available for platinum electrode fabrication. The numerous, different strategies available to fabricate platinum electrodes are reviewed and discussed in the context of their tuning parameters, strengths and weaknesses. These strategies comprise bottom-up approaches as well as top-down approaches. In bottom-up approaches nanoparticles are synthesized in a first step by chemical, photochemical or sonochemical means followed by an electrode formation step by e.g. thin film technology or network formation to create a contiguous and conducting solid electrode structure. In top-down approaches fabrication starts with an already conductive electrode substrate. Corresponding strategies enable the fabrication of substrate-based electrodes by e.g. electrodeposition or the fabrication of self-supporting electrodes by dealloying. As a further top-down strategy, this review describes methods to decorate porous metals other than platinum with a surface layer of platinum. This way, fabrication methods not performable with platinum can be applied to the fabrication of platinum electrodes with the special benefit of low platinum consumption. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Adherence of pediatric patients to automated peritoneal dialysis.

    Science.gov (United States)

    Chua, Annabelle N; Warady, Bradley A

    2011-05-01

    Little information is available on adherence to a home automated peritoneal dialysis (APD) prescription for children with end-stage renal disease. We have therefore retrospectively reviewed HomeChoice PRO Card data from patients Adherence was characterized as occurring ≥ 95%, 90-94%, or treatment adherence and patient age, gender, race and if the patient had received training, respectively, was assessed. Of the 51 patients (57% male), with a mean age at peritoneal dialysis (PD) onset of 11.8 ± 5.3 years, 28 (55%) were adherent for all variables. No difference in mean age or if patients were trained existed between the two groups. Males were more likely to be non-adherent (p = 0.026) as were African Americans (p = 0.048). The majority of patients were adherent to duration (96%) and number of cycles (92%), whereas non-adherence was more common with number of sessions (82%) and dialysate volume (78%). In conclusion, 45% of the pediatric patients in our study cohort exhibited some non-adherence to their prescribed APD regimen, emphasizing the value of closely monitoring the performance of home dialysis in children.

  18. Prevention is better than cure – the art of avoiding non-adherence to antiretroviral treatment

    Directory of Open Access Journals (Sweden)

    Leith Kwaan

    2010-11-01

    Full Text Available The much-used phrase ‘prevention is better than cure’ is applicable to many circumstances, including human immunodeficiency virus (HIV infection. In recent years suggestions have been made for a move towards treatment strategies that emphasise prevention of foreseeable adherence problems on a patient-by-patient basis, through focused patient preparation before commencing antiretroviral therapy (ART. This is well elucidated in a statement made in 2004 by Coetzee et al.:1 ‘As it is difficult to ascertain robust predictors of adherence, there has been a move to concentrate on patient preparation before the initiation of ART rather than the use of non-clinical predictors of adherence or selection criteria. A paradigm focused on preparation rather than selection is better suited to the aggressive targets for the scaling up of ART in countries with large epidemics (such as in South Africa, where the view of ART as a very expensive rationed intervention is rapidly changing.’

  19. Titanyl phthalocyanine ambipolar thin film transistors making use of carbon nanotube electrodes

    International Nuclear Information System (INIS)

    Coppedè, Nicola; Tarabella, Giuseppe; Ranzieri, Paolo; Iannotta, Salvatore; Valitova, Irina; Cicoira, Fabio; Mahvash, Farzaneh; Santato, Clara; Martel, Richard

    2014-01-01

    The capability of efficiently injecting charge carriers into organic films and finely tuning their morphology and structure is crucial to improve the performance of organic thin film transistors (OTFTs). In this work, we investigate OTFTs employing carbon nanotubes (CNTs) as the source-drain electrodes and, as the organic semiconductor, thin films of titanyl phthalocyanine (TiOPc) grown by supersonic molecular beam deposition (SuMBD). While CNT electrodes have shown an unprecedented ability to improve charge injection in OTFTs, SuMBD is an effective technique to tune film morphology and structure. Varying the substrate temperature during deposition, we were able to grow both amorphous (low substrate temperature) and polycrystalline (high substrate temperature) films of TiOPc. Regardless of the film morphology and structure, CNT electrodes led to superior charge injection and transport performance with respect to benchmark Au electrodes. Vacuum annealing of polycrystalline TiOPc films with CNT electrodes yielded ambipolar OTFTs. (paper)

  20. Disposable Non-Enzymatic Glucose Sensors Using Screen-Printed Nickel/Carbon Composites on Indium Tin Oxide Electrodes

    Directory of Open Access Journals (Sweden)

    Won-Yong Jeon

    2015-12-01

    Full Text Available Disposable screen-printed nickel/carbon composites on indium tin oxide (ITO electrodes (DSPNCE were developed for the detection of glucose without enzymes. The DSPNCE were prepared by screen-printing the ITO substrate with a 50 wt% nickel/carbon composite, followed by curing at 400 °C for 30 min. The redox couple of Ni(OH2/NiOOH was deposited on the surface of the electrodes via cyclic voltammetry (CV, scanning from 0–1.5 V for 30 cycles in 0.1 M NaOH solution. The DSPNCE were characterized by field-emission scanning electron microscopy (FE-SEM, X-ray photoelectron spectroscopy (XPS, and electrochemical methods. The resulting electrical currents, measured by CV and chronoamperometry at 0.65 V vs. Ag/AgCl, showed a good linear response with glucose concentrations from 1.0–10 mM. Also, the prepared electrodes showed no interference from common physiologic interferents such as uric acid (UA or ascorbic acid (AA. Therefore, this approach allowed the development of a simple, disposable glucose biosensor.

  1. Disposable Non-Enzymatic Glucose Sensors Using Screen-Printed Nickel/Carbon Composites on Indium Tin Oxide Electrodes.

    Science.gov (United States)

    Jeon, Won-Yong; Choi, Young-Bong; Kim, Hyug-Han

    2015-12-10

    Disposable screen-printed nickel/carbon composites on indium tin oxide (ITO) electrodes (DSPNCE) were developed for the detection of glucose without enzymes. The DSPNCE were prepared by screen-printing the ITO substrate with a 50 wt% nickel/carbon composite, followed by curing at 400 °C for 30 min. The redox couple of Ni(OH)₂/NiOOH was deposited on the surface of the electrodes via cyclic voltammetry (CV), scanning from 0-1.5 V for 30 cycles in 0.1 M NaOH solution. The DSPNCE were characterized by field-emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), and electrochemical methods. The resulting electrical currents, measured by CV and chronoamperometry at 0.65 V vs. Ag/AgCl, showed a good linear response with glucose concentrations from 1.0-10 mM. Also, the prepared electrodes showed no interference from common physiologic interferents such as uric acid (UA) or ascorbic acid (AA). Therefore, this approach allowed the development of a simple, disposable glucose biosensor.

  2. Modification of titanium electrodes by a noble metal deposit

    Energy Technology Data Exchange (ETDEWEB)

    Devilliers, D.; Mahe, E. [Pierre et Marie Curie Univ., Paris (France). Laboratoire LI2C, UMR CNRS

    2008-07-01

    Titanium is commonly used as a substrate for dimensionally stable anodes (DSAs) because it is corrosion-resistant in acid media and because a passive titanium oxide (TiO2) film can be formed on the surface. This paper reported on a study in which titanium substrates were first covered by anodization with a TiO2 layer. The electrochemical properties of the Ti/TiO2 electrodes were investigated. The modification of the substrates by cathodic electrodeposition of a noble metal was described. The reactivity of the Ti/TiO2/Pt structures were illustrated by impedance spectroscopy experiments. The impedance studies performed with Ti/ TiO2 electrodes in the presence of a redox couple in solution (Fe3+/Fe2+ system in sulphuric acid) showed that the electronic transfer is very slow. It was concluded that the deposition of a noble metal coating on Ti/TiO2 substrates leads to modified titanium electrodes that exhibit electrocatalytic behaviour versus specific electrochemical reactions. 1 ref., 3 figs.

  3. Dietary Adherence, Glycemic Control, and Psychological Factors Associated with Binge Eating Among Indigenous and Non-Indigenous Chileans with Type 2 Diabetes.

    Science.gov (United States)

    Herbozo, Sylvia; Flynn, Patricia M; Stevens, Serena D; Betancourt, Hector

    2015-12-01

    Despite the strong association between obesity and binge eating, limited research has examined the implications of binge eating on dietary adherence and psychological factors in ethnically diverse type 2 diabetes patients. This study investigated the prevalence of binge eating and its association with dietary adherence, glycemic control, and psychological factors among indigenous and non-indigenous type 2 diabetes patients in Chile. Participants were 387 indigenous (Mapuche) and non-indigenous (non-Mapuche) adults with type 2 diabetes. Self-report measures of binge eating, dietary adherence, diet self-efficacy, body image dissatisfaction, and psychological well-being were administered. Participants' weight, height, and glycemic control (HbA(1c)) were also obtained. Approximately 8 % of the type 2 diabetes patients reported binge eating. The prevalence among Mapuche patients was 4.9 %, and among non-Mapuche patients, it was 9.9 %. Compared to non-binge eaters, binge eating diabetes patients had greater body mass index values, consumed more high-fat foods, were less likely to adhere to their eating plan, and reported poorer body image and emotional well-being. Results of this study extend previous research by examining the co-occurrence of binge eating and type 2 diabetes as well as the associated dietary behaviors, glycemic control, and psychological factors among indigenous and non-indigenous patients in Chile. These findings may increase our understanding of the health challenges faced by indigenous populations from other countries and highlight the need for additional research that may inform interventions addressing binge eating in diverse patients with type 2 diabetes.

  4. Organic light emitting diode with light extracting electrode

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Abhinav; Buhay, Harry

    2017-04-18

    An organic light emitting diode (10) includes a substrate (20), a first electrode (12), an emissive active stack (14), and a second electrode (18). At least one of the first and second electrodes (12, 18) is a light extracting electrode (26) having a metallic layer (28). The metallic layer (28) includes light scattering features (29) on and/or in the metallic layer (28). The light extracting features (29) increase light extraction from the organic light emitting diode (10).

  5. Paper-based potentiometric pH sensor using carbon electrode drawn by pencil

    Science.gov (United States)

    Kawahara, Ryotaro; Sahatiya, Parikshit; Badhulika, Sushmee; Uno, Shigeyasu

    2018-04-01

    A flexible and disposable paper-based pH sensor fabricated with a pencil-drawn working electrode and a Ag/AgCl paste reference electrode is demonstrated for the first time to show pH response by the potentiometric principle. The sensor substrate is made of chromatography paper with a wax-printed hydrophobic area, and various types of carbon pencils are tested as working electrodes. The pH sensitivities of the electrodes drawn by carbon pencils with different hardnesses range from 16.5 to 26.9 mV/pH. The proposed sensor is expected to be more robust against shape change in electrodes on a flexible substrate than other types of chemiresistive/amperometric pH sensors.

  6. Emotional distress as a predictor of statin non-adherence among Swedish first-time myocardial infarction patients, 2006-2013.

    Science.gov (United States)

    Lissåker, C T; Wallert, J; Held, C; Olsson, E

    2017-06-01

    Emotional distress (depression and anxiety) has been known to affect mortality after a myocardial infarction (MI). One possible mechanism is through medication non-adherence. Few studies have investigated the link between statin adherence and emotional distress, and results are not consistent. We aimed to explore whether emotional distress affects adherence among first-time MI patients younger than 75years old receiving a prescription for the first time. We identified first-MI individuals younger than 75years from the SWEDEHEART national quality registers discharged with a statin prescription. The main exposure was the anxiety/depression portion of the EQ-5D from Interview 1 (6-10weeks post-MI) and Interview 2 (12-14months post-MI). We calculated adherence from the Swedish Prescribed Drugs Register during three observation periods (OP): [1] Interview 1 to Interview 2, [2] one year post Interview 2, and [3] two years post Interview 1. Emotional distress at Interview 1 was not associated with statin adherence for OP1 (RR: 0.99, 95% CI: 0.98, 1.01). Emotional distress at Interview 2 was associated with lower adherence one year later (RR: 0.95, 95% CI: 0.93, 0.98). Emotional distress at Interview 1 was associated with a small decrease in adherence in the complete OP for adherence (RR: 0.98, 95% CI: 0.96, 0.99). Emotional distress was marginally, but independently, associated with lower adherence to statin two years after the MI. Our study suggests that emotional distress may be an important factor for long-term statin adherence, and, thus, may play a clinically important role in long-term outcome. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Lipase immobilized on nanostructured cerium oxide thin film coated on transparent conducting oxide electrode for butyrin sensing

    International Nuclear Information System (INIS)

    Panky, Sreedevi; Thandavan, Kavitha; Sivalingam, Durgajanani; Sethuraman, Swaminathan; Krishnan, Uma Maheswari; Jeyaprakash, Beri Gopalakrishnan; Rayappan, John Bosco Balaguru

    2013-01-01

    Nanostructured cerium oxide (CeO 2 ) thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique with cerium nitrate salt, Ce(NO 3 ) 3 ·6H 2 O as precursor. Fluorine doped cadmium oxide (CdO:F) thin film prepared using spray pyrolysis technique acts as the TCO film and hence the bare electrode. The structural, morphological and elemental characterizations of the films were carried out using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray analysis (EDX) respectively. The diffraction peak positions in XRD confirmed the formation of highly crystalline ceria with cubic structure and FE-SEM images showed uniform adherent films with granular morphology. The band gaps of CeO 2 and TCO were found to be 3.2 eV and 2.6 eV respectively. Lipase enzyme was physisorbed on the surface of CeO 2 /TCO film to form the lipase/nano-CeO 2 /TCO bioelectrode. Sensing studies were carried out using cyclic voltammetry and amperometry, with lipase/nano-CeO 2 /TCO as working electrode and tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33–1.98 mM) with a lowest detection limit of 2 μM with sharp response time of 5 s and a shelf life of about 6 weeks. -- Graphical abstract: Nanostructured cerium oxide thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique. Fluorine doped cadmium oxide (CdO:F) thin film acts as the TCO film and hence the working electrode. Lipase enzyme was physisorbed on the surface of CeO 2 /TCO film and hence the lipase/nano-CeO 2 /TCO bioelectrode has been fabricated. Sensing studies were carried out using cyclic voltammetry and amperometry with tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33–1.98 mM) with a lowest detection limit of 2 μM with sharp response time of 5 s and a shelf life of about 6

  8. Suboptimal adherence to doxycycline and treatment outcomes among men with non-gonococcal urethritis: a prospective cohort study.

    Science.gov (United States)

    Khosropour, Christine M; Manhart, Lisa E; Colombara, Danny V; Gillespie, Catherine W; Lowens, M Sylvan; Totten, Patricia A; Golden, Matthew R; Simoni, Jane

    2014-02-01

    Doxycycline, one of two recommended therapies for non-gonococcal urethritis (NGU), consists of a 7-day course of therapy (100 mg BID). Since suboptimal adherence may contribute to poor treatment outcomes, we examined the association between self-reported imperfect adherence to doxycycline and clinical and microbiologic failure among men with NGU. Men aged ≥16 years with NGU attending a Seattle, WA, sexually transmitted diseases clinic were enrolled in a double-blind, parallel-group superiority trial from January 2007 to July 2011. Men were randomised to active doxycycline/placebo azithromycin or placebo doxycycline/active azithromycin. Imperfect adherence was defined as missing ≥1 dose in 7 days. Urine was tested for Chlamydia trachomatis (CT), Mycoplasma genitalium (MG), and Ureaplasma urealyticum-biovar 2 (UU-2) using nucleic acid amplification tests. Clinical failure (symptoms and ≥5 PMNs/HPF or discharge) and microbiologic failure (positive tests for CT, MG, and/or UU-2) were determined after 3 weeks. 184 men with NGU were randomised to active doxycycline and provided data on adherence. Baseline prevalence of CT, MG and UU-2 was 26%, 13% and 27%, respectively. 28% of men reported imperfect adherence, and this was associated with microbiologic failure among men with CT (aRR=9.33; 95% CI 1.00 to 89.2) and UU-2 (aRR=3.08; 95% CI 1.31 to 7.26) but not MG. Imperfect adherence was not significantly associated with clinical failure overall or for any specific pathogens, but it was more common among imperfectly adherent men with CT (aRR=2.63; 0.93-7.41, p=0.07). Adherence may be important for microbiologic cure of select pathogens. Factors other than adherence should be considered for CT-negative men with persistent NGU.

  9. Electrochemical studies of iron/carbonates system applied to the formation of thin layers of siderite on inert substrates

    International Nuclear Information System (INIS)

    Ithurbide, A.; Peulon, S.; Mandin, Ph.; Beaucaire, C.; Chausse, A.

    2007-01-01

    In order to understand the complex mechanisms of the reactions occurring, a methodology is developed. It is based on the use of compounds electrodeposited under the form of thin layers and which are used then as electrodes to study their interactions with the toxic species. It is in this framework that is studied the electrodeposition of siderite on inert substrates. At first, have been studied iron electrochemical systems in carbonated solutions. These studies have been carried out with classical electrochemical methods (cyclic voltametry, amperometry) coupled to in-situ measurements: quartz microbalance, pH. Different compounds have been obtained under the form of homogeneous and adherent thin layers. The analyses of these depositions, by different ex-situ characterizations (XRD, IR, SEM, EDS..) have revealed particularly the presence of siderite. Then, the influence of several experimental parameters (substrate, potential, medium composition, temperature) on the characteristics of siderite thin layers has been studied. From these experimental results, models have been proposed. (O.M.)

  10. Ultra-Thin Optically Transparent Carbon Electrodes Produced from Layers of Adsorbed Proteins

    Science.gov (United States)

    Alharthi, Sarah A.; Benavidez, Tomas E.; Garcia, Carlos D.

    2013-01-01

    This work describes a simple, versatile, and inexpensive procedure to prepare optically transparent carbon electrodes, using proteins as precursors. Upon adsorption, the protein-coated substrates were pyrolyzed under reductive conditions (5% H2) to form ultra-thin, conductive electrodes. Because proteins spontaneously adsorb to interfaces forming uniform layers, the proposed method does not require a precise control of the preparation conditions, specialized instrumentation, or expensive precursors. The resulting electrodes were characterized by a combination of electrochemical, optical, and spectroscopic means. As a proof-of-concept, the optically-transparent electrodes were also used as substrate for the development of an electrochemical glucose biosensor. The proposed films represent a convenient alternative to more sophisticated, and less available, carbon-based nanomaterials. Furthermore, these films could be formed on a variety of substrates, without classical limitations of size or shape. PMID:23421732

  11. Modified electrode voltammetric sensors for trace metals in environmental samples

    Directory of Open Access Journals (Sweden)

    Brett Christopher M.A.

    2000-01-01

    Full Text Available Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.

  12. Understanding rational non-adherence to medications. A discrete choice experiment in a community sample in Australia

    Directory of Open Access Journals (Sweden)

    Laba Tracey-Lea

    2012-06-01

    Full Text Available Abstract Background In spite of the potential impact upon population health and expenditure, interventions promoting medication adherence have been found to be of moderate effectiveness and cost effectiveness. Understanding the relative influence of factors affecting patient medication adherence decisions and the characteristics of individuals associated with variation in adherence will lead to a better understanding of how future interventions should be designed and targeted. This study aims to explore medication-taking decisions that may underpin intentional medication non-adherence behaviour amongst a community sample and the relative importance of medication specific factors and patient background characteristics contributing to those decisions. Methods A discrete choice experiment conducted through a web-enabled online survey was used to estimate the relative importance of eight medication factors (immediate and long-term medication harms and benefits, cost, regimen, symptom severity, alcohol restrictions on the preference to continue taking a medication. To reflect more closely what usually occurs in practice, non-disease specific medication and health terms were used to mimic decisions across multiple medications and conditions.161 general community participants, matching the national Australian census data (age, gender were recruited through an online panel provider (participation rate: 10% in 2010. Results Six of the eight factors (i.e. immediate and long-term medication harms and benefits, cost, and regimen had a significant influence on medication choice. Patient background characteristics did not improve the model. Respondents with private health insurance appeared less sensitive to cost then those without private health insurance. In general, health outcomes, framed as a side-effect, were found to have a greater influence over adherence than outcomes framed as therapeutic benefits. Conclusions Medication-taking decisions are the

  13. Understanding rational non-adherence to medications. A discrete choice experiment in a community sample in Australia.

    Science.gov (United States)

    Laba, Tracey-Lea; Brien, Jo-Anne; Jan, Stephen

    2012-06-20

    In spite of the potential impact upon population health and expenditure, interventions promoting medication adherence have been found to be of moderate effectiveness and cost effectiveness. Understanding the relative influence of factors affecting patient medication adherence decisions and the characteristics of individuals associated with variation in adherence will lead to a better understanding of how future interventions should be designed and targeted. This study aims to explore medication-taking decisions that may underpin intentional medication non-adherence behaviour amongst a community sample and the relative importance of medication specific factors and patient background characteristics contributing to those decisions. A discrete choice experiment conducted through a web-enabled online survey was used to estimate the relative importance of eight medication factors (immediate and long-term medication harms and benefits, cost, regimen, symptom severity, alcohol restrictions) on the preference to continue taking a medication. To reflect more closely what usually occurs in practice, non-disease specific medication and health terms were used to mimic decisions across multiple medications and conditions.161 general community participants, matching the national Australian census data (age, gender) were recruited through an online panel provider (participation rate: 10%) in 2010. Six of the eight factors (i.e. immediate and long-term medication harms and benefits, cost, and regimen) had a significant influence on medication choice. Patient background characteristics did not improve the model. Respondents with private health insurance appeared less sensitive to cost then those without private health insurance. In general, health outcomes, framed as a side-effect, were found to have a greater influence over adherence than outcomes framed as therapeutic benefits. Medication-taking decisions are the subject of rational choices, influenced by the attributes of

  14. Carbon fiber brush electrode as a novel substrate for atmospheric solids analysis probe (ASAP) mass spectrometry: Electrochemical oxidation of brominated phenols.

    Science.gov (United States)

    Skopalová, Jana; Barták, Petr; Bednář, Petr; Tomková, Hana; Ingr, Tomáš; Lorencová, Iveta; Kučerová, Pavla; Papoušek, Roman; Borovcová, Lucie; Lemr, Karel

    2018-01-25

    A carbon fiber brush electrode (CFBE) was newly designed and used as a substrate for both controlled potential electrolysis and atmospheric solids analysis probe (ASAP) mass spectrometry. Electropolymerized and strongly adsorbed products of electrolysis were directly desorbed and ionized from the electrode surface. Electrochemical properties of the electrode investigated by cyclic voltammetry revealed large electroactive surface area (23 ± 3 cm 2 ) at 1.3 cm long array of carbon fibers with diameter 6-9 μm. Some products of electrochemical oxidation of pentabromophenol and 2,4,6-tribromophenol formed a compact layer on the carbon fibers and were analyzed using ASAP. Eleven new oligomeric products were identified including quinones and biphenoquinones. These compounds were not observed previously in electrolyzed solutions by liquid or gas chromatography/mass spectrometry. The thickness around 58 nm and 45 nm of the oxidation products layers deposited on carbon fibers during electrolysis of pentabromophenol and 2,4,6-tribromophenol, respectively, was estimated from atomic force microscopy analysis and confirmed by scanning electron microscopy with energy-dispersive X-ray spectroscopy measurements. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A model for electrode effects using percolation theory

    International Nuclear Information System (INIS)

    Wuethrich, R.; Bleuler, H.

    2004-01-01

    Electrode effects are known for more than 150 years. These effects, with undesirable consequences in industrial aluminium electrolysis, can be used to micro-machine glass with Spark Assisted Chemical Engraving (SACE). In this paper, a novel approach for theoretical analysis of the phenomenon is proposed by considering the bubble growth and bubble departure from electrodes as a stochastic process. The critical conditions (critical voltage and current density) are predicted in function of electrode geometry and electrolyte concentration as well as the static mean current-voltage characteristics prior to the onset of the effects. The different regions of the current-voltage characteristics, as identified by previous authors, are described and explained. It is shown that all relevant processes for the onset of the electrodes effects happen in the adherence region of the bubble layer. The model is applied for vertical cylindrical electrodes and compared with experimental data

  16. Influence of non-adherent yeast cells on electrical characteristics of diamond-based field-effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Procházka, Václav, E-mail: prochazkav@fzu.cz [Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 16627 Prague (Czech Republic); Institute of Physics, The Czech Academy of Sciences, Cukrovarnická 10/112, 162 00 Prague (Czech Republic); Cifra, Michal [Institute of Photonics and Electronics, The Czech Academy of Sciences, Chaberská 57, 182 51 Prague (Czech Republic); Kulha, Pavel [Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 16627 Prague (Czech Republic); Institute of Physics, The Czech Academy of Sciences, Cukrovarnická 10/112, 162 00 Prague (Czech Republic); Ižák, Tibor [Institute of Physics, The Czech Academy of Sciences, Cukrovarnická 10/112, 162 00 Prague (Czech Republic); Rezek, Bohuslav [Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 16627 Prague (Czech Republic); Institute of Physics, The Czech Academy of Sciences, Cukrovarnická 10/112, 162 00 Prague (Czech Republic); Kromka, Alexander [Institute of Physics, The Czech Academy of Sciences, Cukrovarnická 10/112, 162 00 Prague (Czech Republic); Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 16629 Prague (Czech Republic)

    2017-02-15

    Highlights: • Interaction of non-adherent yeast cells with H-terminated diamond described. • Effect of cell culture solutions on H-diamond SGFET (positive potential shifts). • H-diamond sensitive to metabolic activity of yeast cells (negative potential shift). - Abstract: Diamond thin films provide unique features as substrates for cell cultures and as bio-electronic sensors. Here we employ solution-gated field effect transistors (SGFET) based on nanocrystalline diamond thin films with H-terminated surface which exhibits the sub-surface p-type conductive channel. We study an influence of yeast cells (Saccharomyces cerevisiae) on electrical characteristics of the diamond SGFETs. Two different cell culture solutions (sucrose and yeast peptone dextrose–YPD) are used, with and without the cells. We have found that transfer characteristics of the SGFETs exhibit a negative shift of the gate voltage by −26 mV and −42 mV for sucrose and YPD with cells in comparison to blank solutions without the cells. This effect is attributed to a local pH change in close vicinity of the H-terminated diamond surface due to metabolic processes of the yeast cells. The pH sensitivity of the diamond-based SGFETs, the role of cell and protein adhesion on the gate surface and the role of negative surface charge of yeast cells on the SGFETs electrical characteristics are discussed as well.

  17. Influence of non-adherent yeast cells on electrical characteristics of diamond-based field-effect transistors

    International Nuclear Information System (INIS)

    Procházka, Václav; Cifra, Michal; Kulha, Pavel; Ižák, Tibor; Rezek, Bohuslav; Kromka, Alexander

    2017-01-01

    Highlights: • Interaction of non-adherent yeast cells with H-terminated diamond described. • Effect of cell culture solutions on H-diamond SGFET (positive potential shifts). • H-diamond sensitive to metabolic activity of yeast cells (negative potential shift). - Abstract: Diamond thin films provide unique features as substrates for cell cultures and as bio-electronic sensors. Here we employ solution-gated field effect transistors (SGFET) based on nanocrystalline diamond thin films with H-terminated surface which exhibits the sub-surface p-type conductive channel. We study an influence of yeast cells (Saccharomyces cerevisiae) on electrical characteristics of the diamond SGFETs. Two different cell culture solutions (sucrose and yeast peptone dextrose–YPD) are used, with and without the cells. We have found that transfer characteristics of the SGFETs exhibit a negative shift of the gate voltage by −26 mV and −42 mV for sucrose and YPD with cells in comparison to blank solutions without the cells. This effect is attributed to a local pH change in close vicinity of the H-terminated diamond surface due to metabolic processes of the yeast cells. The pH sensitivity of the diamond-based SGFETs, the role of cell and protein adhesion on the gate surface and the role of negative surface charge of yeast cells on the SGFETs electrical characteristics are discussed as well.

  18. Reasons for non-adherence to the dapivirine vaginal ring: results of the MTN-032/ AHA study.

    Science.gov (United States)

    Montgomery, Elizabeth T; Stadler, Jonathan; Naidoo, Sarita; Katz, Ariana; Laborde, Nicole; Garcia, Morgan; Reddy, Krishnaveni; Mansoor, Leila; Etima, Juliane; Zimba, Chifundo; Chitukuta, Miria; Soto-Torres, Lydia

    2018-05-11

    METHODS:: Former ASPIRE participants were stratified by age group (18-21; 22-45) and randomly selected at seven sites in Malawi, South Africa, Uganda and Zimbabwe, 12-17 months after trial exit. Using in-depth interviews or focus group discussions, ring use barriers were explored using structured guides and visual tools including individual-level depictions of dapivirine levels detected in plasma and returned rings. 187 were enrolled; 37% were 18-21 when they began ASPIRE. Most (75%) had drug-level results suggesting inconsistent ring use throughout ASPIRE. Participants viewed themselves as adherent, while simultaneously describing regular instances and reasons for ring removal (e.g. for sex or menses). Less adherent women reported fears that partners would oppose the ring or feel it during sex. High adherers expressed altruistic motivations for ring use. Women of all ages attributed young women's non-adherence to their tendency to be less "serious" about the future, HIV prevention and the study; motivated predominantly by benefits; more fearful of fertility-related consequences; and to having less relationship control. When presented with objective adherence data, participants provided reasons for intermittent ring use, while simultaneously portraying themselves as consistent ring users. Further research is needed to understand how women could use the ring in a way that fits into the context of their relationships and their lives while still conferring adequate HIV prophylaxis.

  19. A stretchable electrode array for non-invasive, skin-mounted measurement of electrocardiography (ECG), electromyography (EMG) and electroencephalography (EEG).

    Science.gov (United States)

    Ma, Rui; Kim, Dae-Hyeong; McCormick, Martin; Coleman, Todd; Rogers, John

    2010-01-01

    This paper reports a class of stretchable electrode array capable of intimate, conformal integration onto the curvilinear surfaces of skin on the human body. The designs employ conventional metallic conductors but in optimized mechanical layouts, on soft, thin elastomeric substrates. These devices exhibit an ability to record spontaneous EEG activity even without conductive electrolyte gels, with recorded alpha rhythm responses that are 40% stronger than those collected using conventional tin electrodes and gels under otherwise similar conditions. The same type of device can also measure high quality ECG and EMG signals. The results suggest broad utility for skin-mounted measurements of electrical activity in the body, with advantages in signal levels, wearability and modes of integration compared to alternatives.

  20. Transparent platinum counter electrode for efficient semi-transparent dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Iefanova, Anastasiia; Nepal, Jeevan; Poudel, Prashant; Davoux, Daren; Gautam, Umesh [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Mallam, Venkataiah [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Qiao, Qiquan [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Logue, Brian [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Baroughi, Mahdi Farrokh, E-mail: m.farrokhbaroughi@sdstate.edu [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States)

    2014-07-01

    A method for fabrication of highly transparent platinum counter electrodes (CEs) has been developed based on spray coating of Pt nanoparticles (NPs) on hot substrates. This method leads to 86% reduction in Pt consumption reducing the Pt cost per peak watt of counter electrode from $0.79/Wp down to $0.11/Wp compared to the conventional Pt counter electrodes made by sputter deposition. The simplicity and low cost of this method provide a basis for an up-scalable fabrication process. The Pt NP layer is over 88% transparent, leading to overall transparency of 80% when incorporated with indium tin oxide/glass substrates for functional counter electrodes. This counter electrode exhibits a large surface area and high catalytic activity, comparable to that of the conventional opaque CEs. Semi-transparent dye-sensitized solar cells fabricated based on this counter electrode showed 6.17% power conversion efficiency. - Highlights: • Counter electrode (CE) prepared by spraying nanoparticle (NP) Pt on hot substrate. • Low cost and scalable fabrication process of CE. • The spray deposited CE uses 10 times less Pt compared to the sputtering method. • The CE is 80% transparent and exhibits a large surface and high catalytic activity. • A semitransparent dye-sensitized solar cell with Pt NP CE was 6.17% efficient.

  1. AZO-Ag-AZO transparent electrode for amorphous silicon solar cells

    International Nuclear Information System (INIS)

    Theuring, Martin; Vehse, Martin; Maydell, Karsten von; Agert, Carsten

    2014-01-01

    Metal-based transparent electrodes can be fabricated at low temperatures, which is crucial for various substrate materials and solar cells. In this work, an oxide-metal-oxide (OMO) transparent electrode based on aluminum zinc oxide (AZO) and silver is compared to AZO layers, fabricated at different temperatures and indium tin oxides. With the OMO structure, a sheet resistance of 7.1/square and a transparency above 80% for almost the entire visible spectrum were achieved. The possible application of such electrodes on a textured solar cell was demonstrated on the example of a rough ZnO substrate. An OMO structure is benchmarked in a n-i-p amorphous silicon solar cell against an AZO front contact fabricated at 200 °C. In the experiment, the OMO electrode shows a superior performance with an efficiency gain of 30%. - Highlights: • Multilayer transparent electrode based on aluminum zinc oxide (AZO) and Ag • Comparison of AZO-Ag-AZO transparent electrode to AZO and indium tin oxide • Performance of AZO-Ag-AZO transparent electrodes on textured surfaces • Comparison of amorphous silicon solar cells with different transparent electrodes

  2. A multidisciplinary approach to study the functional properties of neuron-like cell models constituting a living bio-hybrid system: SH-SY5Y cells adhering to PANI substrate

    Directory of Open Access Journals (Sweden)

    S. Caponi

    2016-11-01

    Full Text Available A living bio-hybrid system has been successfully implemented. It is constituted by neuroblastic cells, the SH-SY5Y human neuroblastoma cells, adhering to a poly-anyline (PANI a semiconductor polymer with memristive properties. By a multidisciplinary approach, the biocompatibility of the substrate has been analyzed and the functionality of the adhering cells has been investigated. We found that the PANI films can support the cell adhesion. Moreover, the SH-SY5Y cells were successfully differentiated into neuron-like cells for in vitro applications demonstrating that PANI can also promote cell differentiation. In order to deeply characterize the modifications of the bio-functionality induced by the cell-substrate interaction, the functional properties of the cells have been characterized by electrophysiology and Raman spectroscopy. Our results confirm that the PANI films do not strongly affect the general properties of the cells, ensuring their viability without toxic effects on their physiology. Ascribed to the adhesion process, however, a slight increase of the markers of the cell suffering has been evidenced by Raman spectroscopy and accordingly the electrophysiology shows a reduction at positive stimulations in the cells excitability.

  3. Time-dependent simulation of plasma and electrodes in high-intensity discharge lamps with different electrode shapes

    CERN Document Server

    Flesch, P

    2003-01-01

    The subject of this paper is the modelling of d.c. and a.c. high-intensity Hg-discharge lamps with differently shaped electrodes. Different arc attachments on the electrodes are studied and insight for the development of new electrodes is gained. The model includes the entire discharge plasma (plasma column, hot plasma spots in front of electrodes, near-electrode non-LTE-plasma) as well as anode and cathode. No subdivision of the discharge space into different regions is necessary (like space charge layer, ionization zone, plasma column). This is achieved by using a differential equation for a non-LTE electrical conductivity which is applicable for local thermal equilibrium (LTE-)regions as well as for non-LTE plasma regions close to the electrodes in a high pressure plasma. Modelling results for a 0.6 MPa mercury discharge considering six different electrode shapes (anode and cathode) are presented and compared with experimental results. The electrodes have different diameters and different electrode tips, s...

  4. Deactivation of nickel hydroxide-gold modified electrodes

    OpenAIRE

    Caram, Bruno; Tucceri, Ricardo

    2013-01-01

    The aim of the present work was to study how the charge-transport process of a nickel hydroxide film electrochemically synthesized on a gold substrate is modified when the electrode is stored for a long time. It was found that nickel hydroxide films are deactivated under storage, that is, films became less conductive than films immediately prepared (nondeactivated). This study was carried out in the context of the rotating disc electrode voltammetry when the modified electrode contacts an ele...

  5. Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon

    Directory of Open Access Journals (Sweden)

    Younghun Kim

    2008-10-01

    Full Text Available In this paper, optimal conditions for fabrication of nanoporous platinum (Pt were investigated in order to use it as a sensitive sensing electrode for silicon CMOS integrable non-enzymatic glucose micro-sensor applications. Applied charges, voltages, and temperatures were varied during the electroplating of Pt into the formed nonionic surfactant C16EO8 nano-scaled molds in order to fabricate nanoporous Pt electrodes with large surface roughness factor (RF, uniformity, and reproducibility. The fabricated nanoporous Pt electrodes were characterized using atomic force microscopy (AFM and electrochemical cyclic voltammograms. Optimal electroplating conditions were determined to be an applied charge of 35 mC/mm2, a voltage of -0.12 V, and a temperature of 25 °C, respectively. The optimized nanoporous Pt electrode had an electrochemical RF of 375 and excellent reproducibility. The optimized nanoporous Pt electrode was applied to fabricate non-enzymatic glucose micro-sensor with three electrode systems. The fabricated sensor had a size of 3 mm x 3 mm, air gap of 10 µm, working electrode (WE area of 4.4 mm2, and sensitivity of 37.5 µA•L/mmol•cm2. In addition, it showed large detection range from 0.05 to 30 mmolL-1 and stable recovery responsive to the step changes in glucose concentration.

  6. Common neural substrates support speech and non-speech vocal tract gestures

    OpenAIRE

    Chang, Soo-Eun; Kenney, Mary Kay; Loucks, Torrey M.J.; Poletto, Christopher J.; Ludlow, Christy L.

    2009-01-01

    The issue of whether speech is supported by the same neural substrates as non-speech vocal-tract gestures has been contentious. In this fMRI study we tested whether producing non-speech vocal tract gestures in humans shares the same functional neuroanatomy as non-sense speech syllables. Production of non-speech vocal tract gestures, devoid of phonological content but similar to speech in that they had familiar acoustic and somatosensory targets, were compared to the production of speech sylla...

  7. Preliminary investigation of adherence to antiretroviral therapy ...

    African Journals Online (AJOL)

    Treatment of HIV with highly active antiretroviral therapy (HAART) has resulted in declining morbidity and mortality rates from HIV-associated diseases, but concerns regarding access and adherence are growing. To determine the adherence level and the reasons for non-adhering to antiretroviral therapy (ART) among ...

  8. Substrate independent approach for synthesis of graphene platelet networks

    Science.gov (United States)

    Shashurin, A.; Fang, X.; Zemlyanov, D.; Keidar, M.

    2017-06-01

    Graphene platelet networks (GPNs) comprised of randomly oriented graphene flakes two to three atomic layers thick are synthesized using a novel plasma-based approach. The approach uses a substrate capable of withstanding synthesis temperatures around 800 °C, but is fully independent of the substrate material. The synthesis occurs directly on the substrate surface without the necessity of any additional steps. GPNs were synthesized on various substrate materials including silicon (Si), thermally oxidized Si (SiO2), molybdenum (Mo), nickel (Ni) and copper (Cu), nickel-chromium (NiCr) alloy and alumina ceramics (Al2O3). The mismatch between the atomic structures of sp2 honeycomb carbon networks and the substrate material is fully eliminated shortly after the synthesis initiation, namely when about 100 nm thick deposits are formed on the substrate. GPN structures synthesized on a substrate at a temperature of about 800 °C are significantly more porous in comparison to the much denser packed amorphous carbon deposits synthesized at lower temperatures. The method proposed here can potentially revolutionize the area of electrochemical energy storage by offering a single-step direct approach for the manufacture of graphene-based electrodes for non-Faradaic supercapacitors. Mass production can be achieved using this method if a roll-to-roll system is utilized.

  9. The effect of requesting a reason for non-adherence to a guideline in a long running automated reminder system for PONV prophylaxis

    NARCIS (Netherlands)

    Kooij, Fabian O.; Klok, Toni; Preckel, Benedikt; Hollmann, Markus W.; Kal, Jasper E.

    2017-01-01

    Automated reminders are employed frequently to improve guideline adherence, but limitations of automated reminders are becoming more apparent. We studied the reasons for non-adherence in the setting of automated reminders to test the hypothesis that a separate request for a reason in itself may

  10. Inkjet-Printed Electrodes on A4 Paper Substrates for Low-Cost, Disposable, and Flexible Asymmetric Supercapacitors.

    Science.gov (United States)

    Sundriyal, Poonam; Bhattacharya, Shantanu

    2017-11-08

    Printed electronics is widely gaining much attention for compact and high-performance energy-storage devices because of the advancement of flexible electronics. The development of a low-cost current collector, selection, and utilization of the proper material deposition tool and improvement of the device energy density are major challenges for the existing flexible supercapacitors. In this paper, we have reported an inkjet-printed solid-state asymmetric supercapacitor on commercial A4 paper using a low-cost desktop printer (EPSON L130). The physical properties of all inks have been carefully optimized so that the developed inks are within the printable range, i.e., Fromm number of 4 electrode, and another such structure is printed with activated carbon ink to form a negative electrode. A combination of both of these electrodes is outlaid by fabricating an asymmetric supercapacitor. The assembled asymmetric supercapacitor with poly(vinyl alcohol) (PVA)-LiCl gel electrolyte shows a stable potential window of 0-2.0 V and exhibits outstanding flexibility, good cyclic stability, high rate capability, and high energy density. The fabricated paper-substrate-based flexible asymmetric supercapacitor also displays an excellent electrochemical performances, e.g., a maximum areal capacitance of 1.586 F/cm 2 (1023 F/g) at a current density of 4 mA/cm 2 , highest energy density of 22 mWh/cm 3 at a power density of 0.099 W/cm 3 , a capacity retention of 89.6% even after 9000 charge-discharge cycles, and a low charge-transfer resistance of 2.3 Ω. So, utilization of inkjet printing for the development of paper-based flexible electronics has a strong potential for embedding into the next generation low-cost, compact, and wearable energy-storage devices and other printed electronic applications.

  11. Electrochemical behavior of LiCoO2 as aqueous lithium-ion battery electrodes

    KAUST Repository

    Ruffo, Riccardo; Wessells, Colin; Huggins, Robert A.; Cui, Yi

    2009-01-01

    .e., as the counter electrode. A commercial reference electrode is also present. Both the working and the counter electrodes have been prepared as thin layers on a metallic substrate using the procedures typical for the study of electrodes for lithium-ion batteries

  12. Fabrication and characterization of all-polymer, transparent ferroelectric capacitors on flexible substrates

    KAUST Repository

    Khan, Yasser

    2011-12-01

    All-polymer, transparent ferroelectric devices, based on the functional polymer poly(vinylidene fluoride trifluoroethylene) [P(VDF-TrFE)], have been fabricated on flexible substrates. The performance of the all-polymer devices was studied and compared to devices with metal electrodes. Specifically, poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) [PEDOT:PSS] and platinum (Pt) electrode effects on the morphology, crystallinity and orientation of P(VDF-TrFE) films were investigated. The devices with PEDOT:PSS electrodes showed similar hysteresis and switching current response compared to Pt electrodes but with tremendously improved fatigue performance. Further, the devices with PEDOT:PSS electrodes showed lower coercive field and better fatigue performance than values reported for other polymer electrodes used with P(VDF-TrFE) on flexible substrates. © 2011 Elsevier B.V. All rights reserved.

  13. Electrophoretic deposition of boron-10 in neutron detectors electrodes

    International Nuclear Information System (INIS)

    Oliveira Sampa, M.H. de; Vinhas, L.A.; Vieira, J.M.

    1990-01-01

    Process of boron-10 electrophoresis on large area of aluminum substrates was developed with the aim of using them in the construction of neutron detectors. After definition and optimization of the boron electrophoresis parameters, depositions of boron-10 on aluminum cylinders were performed and used as electrodes in gamma compensated and non-compensated ionization chambers and in proportional detectors. These prototypes were designed and builded at IPEN-CNEN-SP, and submited for characterization tests at IEA-R1 reactor, and they fulfil the technical specifications of the project. (author) [pt

  14. Smartphone Applications for Educating and Helping Non-motivating Patients Adhere to Medication That Treats Mental Health Conditions: Aims and Functioning

    Directory of Open Access Journals (Sweden)

    Angelos P. Kassianos

    2017-10-01

    Full Text Available Background: Patients prescribed with medication that treats mental health conditions benefit the most compared to those prescribed with other types of medication. However, they are also the most difficult to adhere. The development of mobile health (mHealth applications (“apps” to help patients monitor their adherence is fast growing but with limited evidence on their efficacy. There is no evidence on the content of these apps for patients taking psychotropic medication. The aim of this study is to identify and evaluate the aims and functioning of available apps that are aiming to help and educate patients to adhere to medication that treats mental health conditions.Method: Three platform descriptions (Apple, Google, and Microsoft were searched between October 2015 and February 2016. Included apps need to focus on adherence to medication that treats mental health conditions and use at least a reinforcement strategy. Descriptive information was extracted and apps evaluated on a number of assessment criteria using content analysis.Results: Sixteen apps were identified. All apps included self-monitoring properties like reminders and psycho-educational properties like mood logs. It was unclear how the latter were used or how adherence was measured. Major barriers to medication adherence like patients' illness and medication beliefs and attitudes were not considered nor where information to patients about mediation side effects. Very few apps were tailored and none was developed based on established theories explaining the processes for successful medication adherence like cognitions and beliefs. Reported information on app development and validation was poor.Discussion: A variety of apps with different properties that tackle both intentional and unintentional non-adherence from a different perspective are identified. An evidence-based approach and co-creation with patients is needed. This will ensure that the apps increase the possibility to

  15. Smartphone Applications for Educating and Helping Non-motivating Patients Adhere to Medication That Treats Mental Health Conditions: Aims and Functioning.

    Science.gov (United States)

    Kassianos, Angelos P; Georgiou, Giorgos; Papaconstantinou, Electra P; Detzortzi, Angeliki; Horne, Rob

    2017-01-01

    Background: Patients prescribed with medication that treats mental health conditions benefit the most compared to those prescribed with other types of medication. However, they are also the most difficult to adhere. The development of mobile health (mHealth) applications ("apps") to help patients monitor their adherence is fast growing but with limited evidence on their efficacy. There is no evidence on the content of these apps for patients taking psychotropic medication. The aim of this study is to identify and evaluate the aims and functioning of available apps that are aiming to help and educate patients to adhere to medication that treats mental health conditions. Method: Three platform descriptions (Apple, Google, and Microsoft) were searched between October 2015 and February 2016. Included apps need to focus on adherence to medication that treats mental health conditions and use at least a reinforcement strategy. Descriptive information was extracted and apps evaluated on a number of assessment criteria using content analysis. Results: Sixteen apps were identified. All apps included self-monitoring properties like reminders and psycho-educational properties like mood logs. It was unclear how the latter were used or how adherence was measured. Major barriers to medication adherence like patients' illness and medication beliefs and attitudes were not considered nor where information to patients about mediation side effects. Very few apps were tailored and none was developed based on established theories explaining the processes for successful medication adherence like cognitions and beliefs. Reported information on app development and validation was poor. Discussion: A variety of apps with different properties that tackle both intentional and unintentional non-adherence from a different perspective are identified. An evidence-based approach and co-creation with patients is needed. This will ensure that the apps increase the possibility to impact on non-adherence

  16. MWCNT-ruthenium oxide composite paste electrode as non-enzymatic glucose sensor.

    Science.gov (United States)

    Tehrani, Ramin M A; Ab Ghani, Sulaiman

    2012-01-01

    A non-enzymatic glucose sensor of multi-walled carbon nanotube-ruthenium oxide/composite paste electrode (MWCNT-RuO(2)/CPE) was developed. The electrode was characterized by using XRD, SEM, TEM and EIS. Meanwhile, cyclic voltammetry and amperometry were used to check on the performances of the MWCNT-RuO(2)/CPE towards glucose. The proposed electrode has displayed a synergistic effect of RuO(2) and MWCNT on the electrocatalytic oxidation of glucose in 3M NaOH. This was possible via the formation of transitions of two redox pairs, viz. Ru(VI)/Ru(IV) and Ru(VII)/Ru(VI). A linear range of 0.5-50mM glucose and a limit of detection of 33 μM glucose (S/N=3) were observed. There was no significant interference observable from the traditional interferences, viz. ascorbic acid and uric acid. Indeed, results so obtained have indicated that the developed MWCNT-RuO(2)/CPE would pave the way for a better future to glucose sensor development as its fabrication was without the use of any enzyme. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Electrophoretic deposition of thin film zirconia electrolyte on non-conducting NiO-YSZ substrate

    International Nuclear Information System (INIS)

    Das, Debasish; Basu, Rajendra N.

    2014-01-01

    Eight (8) mol% yttria stabilized zirconia (YSZ), an electrolyte material for solid oxide fuel cell (SOFC), has been deposited onto porous non-conducting NiO-YSZ substrate using electrophoretic deposition technique (EPD) from a stable non-aqueous suspension of YSZ. Normally, EPD cannot be performed on a non-conducting substrate, but, in this present study, YSZ particulate film has been successfully deposited on a non-conducting NiO-YSZ substrate following two different EPD approaches:(a) using a conducting metallic plate on the reverse side of the porous NiO-YSZ anode substrate and (b) using a conducting polymer coated NiO-YSZ substrate. The deposited films are then formed dense coatings of 5-15 μm after sintering at 1400℃ for 6 h in air. Surface and cross-sectional morphologies of green and sintered films deposited by different EPD approaches are investigated using SEM. La 0.65 Sr 0.3 MnO 3 (LSM), a cathode for SOFC, is then screen-printed onto the electrolyte layer of such sintered half cells (anode+electrolyte) prepared by both the above approaches to construct SOFC single cells. A maximum output power density of 0.37 W.cm -2 is obtained using single cells prepared by conducting metallic plate assisted EPD compared to that of 0.73 W.cm -2 for polymer coated at 800℃ using H 2 as fuel and O 2 as oxidant. (author)

  18. Manufacture of SOFC electrodes by wet powder spraying

    Energy Technology Data Exchange (ETDEWEB)

    Wilkenhoener, R.; Mallener, W.; Buchkremer, H.P. [Forschungszentrum Juelich GmbH (Germany)] [and others

    1996-12-31

    The reproducible and commercial manufacturing of electrodes with enhanced electrochemical performance is of central importance for a successful technical realization of Solid Oxide Fuel Cell (SOFC) systems. The route of electrode fabrication for the SOFC by Wet Powder Spraying (WPS) is presented. Stabilized suspensions of the powder materials for the electrodes were sprayed onto a substrate by employing a spray gun. After drying of the layers, binder removal and sintering are performed in one step. The major advantage of this process is its applicability for a large variety of materials and its flexibility with regard to layer shape and thickness. Above all, flat or curved substrates of any size can be coated, thus opening up the possibility of {open_quotes}up-scaling{close_quotes} SOFC technology. Electrodes with an enhanced electrochemical performance were developed by gradually optimizing the different process steps. For example an optimized SOFC cathode of the composition La{sub 0.65}Sr{sub 0.3}MnO{sub 3} with 40% 8YSZ showed a mean overpotential of about -50 mV at a current density of -0.8 A/cm{sup 2}, with a standard deviation amounting to 16 mV (950{degrees}C, air). Such optimized electrodes can be manufactured with a high degree of reproducibility, as a result of employing a computer-controlled X-Y system for moving the spray gun. Several hundred sintered composites, comprising the substrate anode and the electrolyte, of 100x 100 mm{sup 2} were coated with the cathode by WPS and used for stack integration. The largest manufactured electrodes were 240x240 mm{sup 2}, and data concerning their thickness homogeneity and electrochemical performance are given.

  19. Fabrication of fuel cell electrodes and other catalytic structures

    Science.gov (United States)

    Smith, J.L.

    1987-02-11

    A porous layer of catalyst material suitable for use as an electrode in a molten carbonate fuel cell includes elongated pores substantially extending across the layer thickness. The catalyst layer is prepared by depositing particulate catalyst material into polymeric flocking on a substrate surface by a procedure such as tape casting. The loaded substrate is heated in a series of steps with rising temperatures to set the tape, thermally decompose the substrate with flocking and sinter bond the catalyst particles into a porous catalytic layer with elongated pores across its thickness. Employed as an electrode, the elongated pores provide distribution of reactant gas into contact with catalyst particles wetted by molten electrolyte. 1 fig.

  20. Fabrication of catalytic electrodes for molten carbonate fuel cells

    Science.gov (United States)

    Smith, James L.

    1988-01-01

    A porous layer of catalyst material suitable for use as an electrode in a molten carbonate fuel cell includes elongated pores substantially extending across the layer thickness. The catalyst layer is prepared by depositing particulate catalyst material into polymeric flocking on a substrate surface by a procedure such as tape casting. The loaded substrate is heated in a series of steps with rising temperatures to set the tape, thermally decompose the substrate with flocking and sinter bond the catalyst particles into a porous catalytic layer with elongated pores across its thickness. Employed as an electrode, the elongated pores provide distribution of reactant gas into contact with catalyst particles wetted by molten electrolyte.

  1. Light addressable gold electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Waqas

    2011-07-01

    The main objective carried out in this dissertation was to fabricate Light Amplified Potentiometric sensors (LAPS) based upon the semiconductor nanoparticles (quantum dots) instead of its bulk form. Quantum dots (QDs) were opted for this device fabrication because of their superior fluorescent, electric and catalytic properties. Also in comparison to their bulk counterparts they will make device small, light weighted and power consumption is much lower. QDs were immobilized on a Au substrate via 1,4 benzene dithiol (BDT) molecule. Initially a self-assembled monolayer (SAM) of BDT was established on Au substrate. Because of SAM, the conductivity of Au substrate decreased dramatically. Furthermore QDs were anchored with the help of BDT molecule on Au substrate. When QDs immobilized on Au substrate (QD/Au) via BDT molecule were irradiated with UV-visible light, electron-hole pairs were generated in QDs. The surface defect states in QDs trapped the excited electrons and long lived electron-hole pairs were formed. By the application of an appropriate bias potential on Au substrate the electrons could be supplied or extracted from the QDs via tunneling through BDT. Thus a cathodic or anodic current could be observed depending upon bias potential under illumination. However without light illumination the QD/Au electrode remained an insulator. To improve the device different modifications were made, including different substrates (Au evaporated on glass, Au evaporated on mica sheets and Au sputtered on SiO{sub 2}/Si) and different dithiol molecules (capped and uncapped biphenyl 4,4' dithiol and capped and uncapped 4,4' dimercaptostilbenes) were tried. Also different QD immobilization techniques (normal incubation, spin coating, layer by layer assembly (LbL) of polyelectrolytes and heat immobilization) were employed. This device was able to detect electrochemically different analytes depending upon the QDs incorporated. For example CdS QDs were able to detect 4

  2. Comparison of gene expression of mitogenic kinin path in adherent and non-adherent CD 34-stem cells using oligonucleotide microarrays.

    Directory of Open Access Journals (Sweden)

    Krzysztof Machaj

    2008-02-01

    Full Text Available One of the more interesting cells present in the umbilical cord blood - as far as their potential clinical use is concerned - are stem cells not presenting the CD34 antigen. These are the pluripotential cells with their biological properties similar to mesenchymal stem cells, with the ability to differentiate into such tissue types as bone, cartilage, nervous (to some extent, glia and muscle. The authors compared the activity of genes coding the proteins in mitogenic signal paths activated by kinin receptors using oligonucleotide microarrays in adherent and non-adherent CD 34- cells derived from umbilical cord blood. In the linear regression model with a 95% prognosis area for differentiating genes outside this area, the following genes were selected: c-jun (present in 3 isoforms and c-fos. The fos and jun genes create the AP-1 transcriptive factor which regulates the expression of genes taking part in numerous cellular processes, including the cell cycle and mitosis. The obtained results shed some light on the molecular processes behind the MSC proliferation and are a starting point for further studies on the mesenchymal stem cell biology.

  3. Factors associated with non-adherence to antiretroviral therapy in adults with AIDS in the first six months of treatment in Salvador, Bahia State, Brazil.

    Science.gov (United States)

    Silva, José Adriano Góes; Dourado, Inês; Brito, Ana Maria de; Silva, Carlos Alberto Lima da

    2015-06-01

    The control of viral replication is essential in the highly active antiretroviral therapy (HAART), and adherence to therapy is instrumental for such control. Individual and external factors influence adhesion to the use of antiretroviral (ARV) drugs. This is a cross-sectional study to investigate factors associated with non-adherence to HAART in AIDS patients in Salvador, Bahia State, Brazil, with age ≥ 13 years and first prescription in 2009. Data was collected from patient charts and pharmacy records. From a total of 216 patients, 65.3% were males; mean age 37.8 ± 9.5 years; single, 67.9%; heterosexual, 64%; more than 8 years of school education, 65.3%; alcohol users, 61.5%; non-smokers, 75,1% or non-illicit drug users, 93.7%. A proportion of 94% started ARV therapy with TCD4+ drug reaction. The prevalence of non-adherence was 25%. The variables associated were: longer time between HIV infection and AIDS (aOR = 3.9), adverse drug reaction (aOR = 2.4), under 34 years of age (aOR = 2.2), less than 8 years of school education (aOR = 2.2) and illicit drugs use (aOR = 2.6). A high-non-adherence rate is an important problem within the first six months of HAART.

  4. Optimization of proximity ligation assay (PLA) for detection of protein interactions and fusion proteins in non-adherent cells: application to pre-B lymphocytes.

    Science.gov (United States)

    Debaize, Lydie; Jakobczyk, Hélène; Rio, Anne-Gaëlle; Gandemer, Virginie; Troadec, Marie-Bérengère

    2017-01-01

    Genetic abnormalities, including chromosomal translocations, are described for many hematological malignancies. From the clinical perspective, detection of chromosomal abnormalities is relevant not only for diagnostic and treatment purposes but also for prognostic risk assessment. From the translational research perspective, the identification of fusion proteins and protein interactions has allowed crucial breakthroughs in understanding the pathogenesis of malignancies and consequently major achievements in targeted therapy. We describe the optimization of the Proximity Ligation Assay (PLA) to ascertain the presence of fusion proteins, and protein interactions in non-adherent pre-B cells. PLA is an innovative method of protein-protein colocalization detection by molecular biology that combines the advantages of microscopy with the advantages of molecular biology precision, enabling detection of protein proximity theoretically ranging from 0 to 40 nm. We propose an optimized PLA procedure. We overcome the issue of maintaining non-adherent hematological cells by traditional cytocentrifugation and optimized buffers, by changing incubation times, and modifying washing steps. Further, we provide convincing negative and positive controls, and demonstrate that optimized PLA procedure is sensitive to total protein level. The optimized PLA procedure allows the detection of fusion proteins and protein interactions on non-adherent cells. The optimized PLA procedure described here can be readily applied to various non-adherent hematological cells, from cell lines to patients' cells. The optimized PLA protocol enables detection of fusion proteins and their subcellular expression, and protein interactions in non-adherent cells. Therefore, the optimized PLA protocol provides a new tool that can be adopted in a wide range of applications in the biological field.

  5. Electrochemical deposition of molybdenum sulfide thin films on conductive plastic substrates as platinum-free flexible counter electrodes for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Chao-Kuang; Hsieh, Chien-Kuo, E-mail: jack_hsieh@mail.mcut.edu.tw

    2015-06-01

    In this study, pulsed electrochemical deposition (pulsed ECD) was used to deposit molybdenum sulfide (MoS{sub x}) thin films on indium tin oxide/polyethylene naphthalate (ITO/PEN) substrates as flexible counter electrodes (CEs) for dye-sensitized solar cells (DSSCs). The surface morphologies and elemental distributions of the prepared MoS{sub x} thin films were examined using field-emission scanning electron microscope (FE-SEM) equipped with energy-dispersive X-ray spectroscopy. The chemical states and crystallinities of the prepared MoS{sub x} thin films were examined by X-ray photoelectron spectroscopy and X-ray diffraction, respectively. The optical transmission (T (%)) properties of the prepared MoS{sub x} samples were determined by ultraviolet–visible spectrophotometry. Cyclic voltammetry (CV) and Tafel-polarization measurements were performed to analyze the electrochemical properties and catalytic activities of the thin films for redox reactions. The FE-SEM results showed that the MoS{sub x} thin films were deposited uniformly on the ITO/PEN flexible substrates via the pulsed ECD method. The CV and Tafel-polarization curve measurements demonstrated that the deposited MoS{sub x} thin films exhibited excellent performances for the reduction of triiodide ions. The photoelectric conversion efficiency (PCE) of the DSSC produced with the pulsed ECD MoS{sub x} thin-film CE was examined by a solar simulator. In combination with a dye-sensitized TiO{sub 2} working electrode and an iodine-based electrolyte, the DSSC with the MoS{sub x} flexible CE showed a PCE of 4.39% under an illumination of AM 1.5 (100 mW cm{sup −2}). Thus, we report that the MoS{sub x} thin films are active catalysts for triiodide reduction. The MoS{sub x} thin films are prepared at room temperature and atmospheric pressure and in a simple and rapid manner. This is an important practical contribution to the production of flexible low-cost thin-film CEs based on plastic substrates. The MoS{sub x

  6. Motion mechanics of non-adherent giant liposomes with a combined optical and atomic force microscope

    Science.gov (United States)

    Moreno-Flores, Susana; Ortíz, Rocío

    2017-11-01

    Herein we present an investigation of the motional dynamics of single mesoscopic bodies of biological relevance with an AFM-based macromanipulation tool and an optical microscope. Giant liposomes are prominent case examples as minimal cell models; studying their mechanics provides a means to address the influence of structural components in the mechanical behaviour of living cells. However, they also pose an experimental challenge due to their lightness, fragility, and high mobility. Their entrapment in wells in a fluid of lower density allows their study under conditions of constrained motion, which enables the synchronous measurement of nanoforces with motion tracking. The procedure enables to estimate sliding friction coefficients and masses of vesicles, and sheds light upon the region between the vesicle and the underlying substrate. The present study paves the way for the investigation of motion and deformation mechanics with one combined technique and a single type of experiment traditionally vetoed to objects that can move as well as deform. Such an approach can be directly applied to cells in suspension, adherent cells or cellular 3D-assemblies so as to assess substrate biocompatibility, monitor adhesion, detachment, motility as well as deformability.

  7. Motion mechanics of non-adherent giant liposomes with a combined optical and atomic force microscope

    International Nuclear Information System (INIS)

    Moreno-Flores, Susana; Ortíz, Rocío

    2017-01-01

    Herein we present an investigation of the motional dynamics of single mesoscopic bodies of biological relevance with an AFM-based macromanipulation tool and an optical microscope. Giant liposomes are prominent case examples as minimal cell models; studying their mechanics provides a means to address the influence of structural components in the mechanical behaviour of living cells. However, they also pose an experimental challenge due to their lightness, fragility, and high mobility. Their entrapment in wells in a fluid of lower density allows their study under conditions of constrained motion, which enables the synchronous measurement of nanoforces with motion tracking. The procedure enables to estimate sliding friction coefficients and masses of vesicles, and sheds light upon the region between the vesicle and the underlying substrate. The present study paves the way for the investigation of motion and deformation mechanics with one combined technique and a single type of experiment traditionally vetoed to objects that can move as well as deform. Such an approach can be directly applied to cells in suspension, adherent cells or cellular 3D-assemblies so as to assess substrate biocompatibility, monitor adhesion, detachment, motility as well as deformability. (paper)

  8. Impact of nanoscale topography on genomics and proteomics of adherent bacteria.

    Science.gov (United States)

    Rizzello, Loris; Sorce, Barbara; Sabella, Stefania; Vecchio, Giuseppe; Galeone, Antonio; Brunetti, Virgilio; Cingolani, Roberto; Pompa, Pier Paolo

    2011-03-22

    Bacterial adhesion onto inorganic/nanoengineered surfaces is a key issue in biotechnology and medicine, because it is one of the first necessary steps to determine a general pathogenic event. Understanding the molecular mechanisms of bacteria-surface interaction represents a milestone for planning a new generation of devices with unanimously certified antibacterial characteristics. Here, we show how highly controlled nanostructured substrates impact the bacterial behavior in terms of morphological, genomic, and proteomic response. We observed by atomic force microscopy (AFM) and scanning electron microscopy (SEM) that type-1 fimbriae typically disappear in Escherichia coli adherent onto nanostructured substrates, as opposed to bacteria onto reference glass or flat gold surfaces. A genetic variation of the fimbrial operon regulation was consistently identified by real time qPCR in bacteria interacting with the nanorough substrates. To gain a deeper insight into the molecular basis of the interaction mechanisms, we explored the entire proteomic profile of E. coli by 2D-DIGE, finding significant changes in the bacteria adherent onto the nanorough substrates, such as regulations of proteins involved in stress processes and defense mechanisms. We thus demonstrated that a pure physical stimulus, that is, a nanoscale variation of surface topography, may play per se a significant role in determining the morphological, genetic, and proteomic profile of bacteria. These data suggest that in depth investigations of the molecular processes of microorganisms adhering to surfaces are of great importance for the design of innovative biomaterials with active biological functionalities.

  9. Adherence as a language game.

    Science.gov (United States)

    Kolberg, Espen Skarstein

    2017-04-01

    Non-adherence, i.e. medication intake behavior not corresponding with agreed recommendations, is associated with increased morbidity and death, and it has been estimated that as many as 50% of patients in developed countries are not taking their medications as prescribed. But even as efforts in improving medication adherence over the years have increased, results are inconsistent, with only a minority of clinical trials showing any improvement in both adherence and clinical outcome. Since patient education is central to promoting good medication adherence, and language is integral to education, perhaps an exploration of the meaning and use of language, using the philosophy of Ludwig Wittgenstein, is in order.

  10. Sub-optimal adherence to doxycycline and treatment outcomes among men with non-gonococcal urethritis: a prospective cohort study

    Science.gov (United States)

    Khosropour, Christine M.; Manhart, Lisa E.; Colombara, Danny V.; Gillespie, Catherine W.; Lowens, M. Sylvan; Totten, Patricia A.; Golden, Matthew R.; Simoni, Jane

    2014-01-01

    Objective Doxycycline, one of two recommended therapies for non-gonococcal urethritis (NGU), consists of a seven-day course of therapy (100mg BID). Since suboptimal adherence may contribute to poor treatment outcomes, we examined the association between self-reported imperfect adherence to doxycycline and clinical and microbiologic failure among men with NGU. Methods Men aged ≥16 years with NGU attending a Seattle, WA sexually transmitted diseases clinic were enrolled in a double-blind, parallel-group superiority trial from January 2007 to July 2011. Men were randomized to active doxycycline/placebo azithromycin or placebo doxycycline/active azithromycin. Imperfect adherence was defined as missing ≥1 dose in 7 days. Urine was tested for Chlamydia trachomatis (CT), Mycoplasma genitalium (MG), and Ureaplasma urealyticum-biovar2 (UU-2) using nucleic acid amplification tests. Clinical failure (symptoms and ≥5 PMNs/HPF or discharge) and microbiologic failure (positive tests for CT, MG, and/or UU-2) were determined after 3-weeks. Results 184 men with NGU were randomized to active doxycycline and provided data on adherence. Baseline prevalence of CT, MG, and UU-2 was 26%, 13%, and 27%, respectively. 28% of men reported imperfect adherence and this was associated with microbiologic failure among men with CT (aRR=9.33; 95% CI=1.00–89.2) and UU-2 (aRR=3.08; 95% CI=1.31–7.26) but not MG. Imperfect adherence was not significantly associated with clinical failure overall or for any specific pathogens, but it was more common among imperfectly adherent men with CT (aRR=2.63; 0.93–7.41, p=0.07). Conclusions Adherence may be important for microbiologic cure of select pathogens. Factors other than adherence should be considered for CT-negative men with persistent NGU. PMID:24106340

  11. Detection of nicotine based on molecularly imprinted TiO{sub 2}-modified electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Wu, C.-T.; Chen, P.-Y.; Chen, J.-G.; Suryanarayanan, Vembu [Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Ho, K.-C. [Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Institute of Polymer Science and Engineering, National Taiwan University, Taipei 10617, Taiwan (China)], E-mail: kcho@ntu.edu.tw

    2009-02-02

    Amperometric detection of nicotine (NIC) was carried out on a titanium dioxide (TiO{sub 2})/poly(3,4-ethylenedioxythiophene) (PEDOT)-modified electrode by a molecular imprinting technique. In order to improve the conductivity of the substrate, PEDOT was coated onto the sintered electrode by in situ electrochemical polymerization of the monomer. The sensing potential of the NIC-imprinted TiO{sub 2} electrode (ITO/TiO{sub 2}[NIC]/PEDOT) in a phosphate-buffered saline (PBS) solution (pH 7.4) containing 0.1 M KCl was determined to be 0.88 V (vs. Ag/AgCl/saturated KCl). The linear detection range for NIC oxidation on the so-called ITO/TiO{sub 2}[NIC]/PEDOT electrode was 0-5 mM, with a sensitivity and limit of detection of 31.35 {mu}A mM{sup -1} cm{sup -2} and 4.9 {mu}M, respectively. When comparing with the performance of the non-imprinted one, the sensitivity ratio was about 1.24. The sensitivity enhancement was attributed to the increase in the electroactive area of the imprinted electrode. The at-rest stability of the ITO/TiO{sub 2}[NIC]/PEDOT electrode was tested over a period of 3 days. The current response remained about 85% of its initial value at the end of 2 days. The ITO/TiO{sub 2}[NIC]/PEDOT electrode showed reasonably good selectivity in distinguishing NIC from its major interferent, (-)-cotinine (COT). Moreover, scanning electrochemical microscopy (SECM) was employed to elucidate the surface morphology of the imprinted and non-imprinted electrodes using Fe(CN){sub 6}{sup 3-}/Fe(CN){sub 6}{sup 4-} as a redox probe on a platinum tip. The imprinted electrode was further characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR)

  12. Adherence in pediatric kidney transplant recipients: solutions for the system.

    Science.gov (United States)

    Steinberg, Elizabeth A; Moss, Mary; Buchanan, Cindy L; Goebel, Jens

    2018-03-01

    Non-adherence remains a significant problem among pediatric (and adult) renal transplant recipients. Non-adherence among solid organ transplant recipients results in US$15-100 million annual costs. Estimates of non-adherence range from 30 to 70% among pediatric patients. Research demonstrates that a 10% decrement in adherence is associated with 8% higher hazard of graft failure and mortality. Focus has begun to shift from patient factors that impact adherence to the contributing healthcare and systems factors. The purpose of this review is to describe problems within the systems implicated in non-adherence and potential solutions that may be related to positive adherence outcomes. Systems issues include insurance and legal regulations, provider and care team barriers to optimal care, and difficulties with transitioning to adult care. Potential solutions include recognition of how systems can work together to improve patient outcomes through improvements in insurance programs, a multi-disciplinary care team approach, evidence-based medical management, pharmacy-based applications and interventions to simplify medication regimens, improved transition protocols, and telehealth/technology-based multi-component interventions. However, there remains a significant lack of reliability in the application of these potential solutions to systems issues that impact patient adherence. Future efforts should accordingly focus on these efforts, likely by leveraging quality improvement and related principles, and on the investigation of the efficacy of these interventions to improve adherence and graft outcomes.

  13. Non-enzymatic glucose sensing platform using self assembled cobalt oxide/graphene nanocomposites immobilized graphite modified electrode

    DEFF Research Database (Denmark)

    Vivekananth, R.; Babu, R. Suresh; Prasanna, K.

    2018-01-01

    A new strategy to prepare the densely packed cobalt oxide (Co3O4)/graphene nanocomposites by a self-assembly method were adopted in this work. A new non-enzymatic glucose determination has been fabricated by using Co3O4/graphene nanocomposites modified electrode as a sensing material. The nanocom...... of the modified electrode for glucose determination has been evaluated in urine samples....

  14. Evaluation of adherence and depression among patients on peritoneal dialysis.

    Science.gov (United States)

    Yu, Zhen Li; Yeoh, Lee Ying; Seow, Ying Ying; Luo, Xue Chun; Griva, Konstadina

    2012-07-01

    It is challenging for dialysis patients to maintain adherence to their medical regimen, and symptoms of depression are prevalent among them. Limited data is available about adherence and depression among patients receiving peritoneal dialysis (PD). This study aimed to examine the rates of treatment non-adherence and depression in PD patients. A total of 20 PD patients (response rate 71.4%; mean age 64.4 ± 11.6 years) were assessed using the Beliefs about Medicines Questionnaire, Self Efficacy for Managing Chronic Disease Scale, Hospital Anxiety and Depression Scale (HAD) and Kidney Disease Quality of Life-Short Form. A self-reported adherence (PD exchanges, medication and diet) scale developed for the study was also included. Medical information (e.g. most recent biochemistry results) was obtained from chart review. The mean self-reported scores indicated an overall high level of adherence, although a significant proportion of patients were non-adherent. Among the latter, 20% of patients were non-adherent to medication and 26% to diet due to forgetfulness, while 15% and 26% of patients admitted to deliberate non-adherence to medication and diet, respectively. Treatment modality, employment, self-care status and self-efficacy were associated with overall adherence. Using a cutoff point of 8 for HAD depression and anxiety subscales, 40% of patients were found to be depressed and 30% had symptoms of anxiety. This is the first study to document treatment adherence and depression among PD patients in Singapore. Findings of high prevalence of depression and anxiety, and reports of poor adherence warrant development of intervention programmes.

  15. Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays

    Science.gov (United States)

    Dowden, B. R.; Frankel, M. A.; Normann, R. A.; Clark, G. A.

    2012-02-01

    High-channel-count intrafascicular electrode arrays provide comprehensive and selective access to the peripheral nervous system. One practical difficulty in using several electrode arrays to evoke coordinated movements in paralyzed limbs is the identification of the appropriate stimulation channels and stimulus parameters to evoke desired movements. Here we present the use of a six degree-of-freedom load cell placed under the foot of a feline to characterize the muscle activation produced by three 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted into the femoral nerves, sciatic nerves, and muscular branches of the sciatic nerves of three cats. Intramuscular stimulation was used to identify the endpoint force directions produced by 15 muscles of the hind limb, and these directions were used to classify the forces produced by each intrafascicular USEA electrode as flexion or extension. For 451 USEA electrodes, stimulus intensities for threshold and saturation muscle forces were identified, and the 3D direction and linearity of the force recruitment curves were determined. Further, motor unit excitation independence for 198 electrode pairs was measured using the refractory technique. This study demonstrates the utility of 3D endpoint force monitoring as a simple and non-invasive metric for characterizing the muscle-activation properties of hundreds of implanted peripheral nerve electrodes, allowing for electrode and parameter selection for neuroprosthetic applications.

  16. Conformally encapsulated multi-electrode arrays with seamless insulation

    Energy Technology Data Exchange (ETDEWEB)

    Tabada, Phillipe J.; Shah, Kedar G.; Tolosa, Vanessa; Pannu, Satinderall S.; Tooker, Angela; Delima, Terri; Sheth, Heeral; Felix, Sarah

    2016-11-22

    Thin-film multi-electrode arrays (MEA) having one or more electrically conductive beams conformally encapsulated in a seamless block of electrically insulating material, and methods of fabricating such MEAs using reproducible, microfabrication processes. One or more electrically conductive traces are formed on scaffold material that is subsequently removed to suspend the traces over a substrate by support portions of the trace beam in contact with the substrate. By encapsulating the suspended traces, either individually or together, with a single continuous layer of an electrically insulating material, a seamless block of electrically insulating material is formed that conforms to the shape of the trace beam structure, including any trace backings which provide suspension support. Electrical contacts, electrodes, or leads of the traces are exposed from the encapsulated trace beam structure by removing the substrate.

  17. Assessing the treatment effect in a randomized controlled trial with extensive non-adherence: the EVOLVE trial.

    Science.gov (United States)

    Kubo, Yumi; Sterling, Lulu Ren; Parfrey, Patrick S; Gill, Karminder; Mahaffey, Kenneth W; Gioni, Ioanna; Trotman, Marie-Louise; Dehmel, Bastian; Chertow, Glenn M

    2015-01-01

    Intention-to-treat (ITT) analysis is widely used to establish efficacy in randomized clinical trials. However, in a long-term outcomes study where non-adherence to study drug is substantial, the on-treatment effect of the study drug may be underestimated using the ITT analysis. The analyses presented herein are from the EVOLVE trial, a double-blind, placebo-controlled, event-driven cardiovascular outcomes study conducted to assess whether a treatment regimen including cinacalcet compared with placebo in addition to other conventional therapies reduces the risk of mortality and major cardiovascular events in patients receiving hemodialysis with secondary hyperparathyroidism. Pre-specified sensitivity analyses were performed to assess the impact of non-adherence on the estimated effect of cinacalcet. These analyses included lag-censoring, inverse probability of censoring weights (IPCW), rank preserving structural failure time model (RPSFTM) and iterative parameter estimation (IPE). The relative hazard (cinacalcet versus placebo) of mortality and major cardiovascular events was 0.93 (95% confidence interval 0.85, 1.02) using the ITT analysis; 0.85 (0.76, 0.95) using lag-censoring analysis; 0.81 (0.70, 0.92) using IPCW; 0.85 (0.66, 1.04) using RPSFTM and 0.85 (0.75, 0.96) using IPE. These analyses, while not providing definitive evidence, suggest that the intervention may have an effect while subjects are receiving treatment. The ITT method remains the established method to evaluate efficacy of a new treatment; however, additional analyses should be considered to assess the on-treatment effect when substantial non-adherence to study drug is expected or observed. Copyright © 2015 John Wiley & Sons, Ltd.

  18. A psychophysical account of patient non-adherence to medical prescriptions. The case of insulin dose adjustment.

    Science.gov (United States)

    Reach, G

    2013-02-01

    Diabetic patients often do not adjust their insulin doses using the algorithms that they have been taught. While this behavior may intuitively have a number of causes, such as the complexity of the decision or the fear of hypoglycaemia, we propose in this article a more general, "psychophysical", explanation based on behavioral economics concepts used to describe decisions made under uncertainty and risk. The concepts discussed herein may not be familiar to clinicians, who will find here an introduction to theories that may be helpful in understanding some aspects of non-adherence to medical prescriptions. 1) The Prospect Theory of Kahneman and Tversky proposes that choices made in the context of risk are subject to loss aversion. 2) Decisions under uncertainty use mental short cuts called "heuristics", which can lead to biases; for instance, overestimating the probability of the risk. 3) To understand the very concept of risk, emotions must be considered with a special focus on anticipated regret. 4) Finally, selection difficulty is an important determinant of the preference for the status quo. These concepts may be relevant for understanding a preference for the status quo in decisions made in a context of uncertainty and risk, such as insulin dose adjustment. We suggest that these mental mechanisms may also be involved in other aspects of patients' non-adherence. As other common human behaviors, non-adherence may actually often be a consequence of biases resulting from our ways of thinking, being both cognitive and emotional, and, according to Kahneman, more often "fast" than "slow". Empirical studies are needed to support this hypothesis. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  19. Substrate mediated enzyme prodrug therapy.

    Directory of Open Access Journals (Sweden)

    Betina Fejerskov

    Full Text Available In this report, we detail Substrate Mediated Enzyme Prodrug Therapy (SMEPT as a novel approach in drug delivery which relies on enzyme-functionalized cell culture substrates to achieve a localized conversion of benign prodrug(s into active therapeutics with subsequent delivery to adhering cells or adjacent tissues. For proof-of-concept SMEPT, we use surface adhered micro-structured physical hydrogels based on poly(vinyl alcohol, β-glucuronidase enzyme and glucuronide prodrugs. We demonstrate enzymatic activity mediated by the assembled hydrogel samples and illustrate arms of control over rate of release of model fluorescent cargo. SMEPT was not impaired by adhering cells and afforded facile time - and dose - dependent uptake of the in situ generated fluorescent cargo by hepatic cells, HepG2. With the use of a glucuronide derivative of an anticancer drug, SN-38, SMEPT afforded a decrease in cell viability to a level similar to that achieved using parent drug. Finally, dose response was achieved using SMEPT and administration of judiciously chosen concentration of SN-38 glucuronide prodrug thus revealing external control over drug delivery using drug eluting surface. We believe that this highly adaptable concept will find use in diverse biomedical applications, specifically surface mediated drug delivery and tissue engineering.

  20. Low Fatigue in Epitaxial Pb(Zr0.2Ti0.8)O3 on Si Substrates with LaNiO3 Electrodes by RF Sputtering

    Science.gov (United States)

    Wang, Chun; Kryder, Mark H.

    2009-09-01

    Epitaxial PZT (001) thin films with a LaNiO3 bottom electrode were deposited by radio-frequency (RF) sputtering onto Si(001) single-crystal substrates with SrTiO3/TiN buffer layers. Pb(Zr0.2Ti0.8)O3 (PZT) samples were shown to consist of a single perovskite phase and to have an (001) orientation. The orientation relationship was determined to be PZT(001)[110]∥LaNiO3(001)[110]∥SrTiO3 (001)[110]∥TiN(001)[110]∥Si(001)[110]. Atomic force microscope (AFM) measurements showed the PZT films to have smooth surfaces with a roughness of 1.15 nm. The microstructure of the multilayer was studied using transmission electron microscopy (TEM). Electrical measurements were conducted using both Pt and LaNiO3 as top electrodes. The measured remanent polarization P r and coercive field E c of the PZT thin film with Pt top electrodes were 23 μC/cm2 and 75 kV/cm, and were 25 μC/cm2 and 60 kV/cm for the PZT film with LaNiO3 top electrodes. No obvious fatigue after 1010 switching cycles indicated good electrical endurance of the PZT films using LaNiO3 electrodes, compared with the PZT film with Pt top electrodes showing a significant polarization loss after 108 cycles. These PZT films with LaNiO3 electrodes could be potential recording media for probe-based high-density data storage.

  1. Non-linear response of electrode-electrolyte interface at high current density

    International Nuclear Information System (INIS)

    Ruiz, G.A.; Felice, C.J.; Valentinuzzi, M.E.

    2005-01-01

    A distributed parameter non-linear circuit is presented as fractal model of an electrode-electrolyte interface. It includes the charge transfer resistance and the double layer capacitance at each fractal level. The circuit explains the linear behavior of its series equivalent resistance R eq with signals of amplitudes eq Fourier spectrum. As a consequence, both the equivalent resistance and reactance drop with voltage, facts reported experimentally by other authors

  2. Physician reported adherence to immunosuppressants in renal transplant patients: Prevalence, agreement, and correlates.

    Science.gov (United States)

    Pabst, Selma; Bertram, Anna; Zimmermann, Tanja; Schiffer, Mario; de Zwaan, Martina

    2015-11-01

    Adherence to immunosuppressants (IS) is crucial to prevent allograft rejection. Even though there is evidence that non-adherence to IS among kidney transplant recipients is common, it is rarely routinely assessed in clinical practice. Especially, little is known about how physicians estimate patients' adherence to IS medication. In a single center, cross-sectional study adult patients at least 1 year after kidney transplantation were asked to complete measures of adherence (BAASIS©, Transplant Effect Questionnaire) and of general psychopathology (anxiety, depression, perceived social support). Also the physicians were asked to estimate their patients' adherence. Medical data (time since transplantation, treatment for rejection, IS serum trough levels and target levels) were taken from the patients' charts. Physicians rated 22 of 238 (9.2%) patients as non-adherent. Physicians' estimations of non-adherence were lower compared to the results of the self-ratings and biopsy-proven rejections. No association was found between physicians' estimates and the variability of IS through levels. Significantly more women and patients who reported that their native language was not German were rated as non-adherent by the physicians. Also, physician-rated non-adherent patients reported significantly higher depression and anxiety scores as well as less social support compared to adherent patients. Our results suggest that physicians tend to underestimate patient non-adherence to IS medication. They appear to use observable cues such as sex, language skills, and elevated anxiety and depression scores in particular, to make inferences about an individual patient's adherence. Underestimation of medication non-adherence may impede physicians' ability to provide high quality care. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Method of preparing a negative electrode including lithium alloy for use within a secondary electrochemical cell

    Science.gov (United States)

    Tomczuk, Zygmunt; Olszanski, Theodore W.; Battles, James E.

    1977-03-08

    A negative electrode that includes a lithium alloy as active material is prepared by briefly submerging a porous, electrically conductive substrate within a melt of the alloy. Prior to solidification, excess melt can be removed by vibrating or otherwise manipulating the filled substrate to expose interstitial surfaces. Electrodes of such as solid lithium-aluminum filled within a substrate of metal foam are provided.

  4. Nanostructured CuO thin film electrodes prepared by spray pyrolysis: a simple method for enhancing the electrochemical performance of CuO in lithium cells

    International Nuclear Information System (INIS)

    Morales, Julian; Sanchez, Luis; Martin, Francisco; Ramos-Barrado, Jose R.; Sanchez, Miguel

    2004-01-01

    Nanostructured CuO thin films were prepared by using a spray pyrolysis method, copper acetate as precursor and stainless steel as substrate. The textural and structural properties of the films were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The SEM images revealed thorough coating of the substrate and thickness of 450-1250 nm; the average particle size as determined from the AFM images ranged from 30 to 160 nm. The XRD patterns revealed the formation of CuO alone and the XPS spectra confirmed the presence of Cu 2+ as the main oxidation state on the surface. The films were tested as electrodes in lithium cells and their electrochemical properties evaluated from galvanostatic and step potential electrochemical spectroscopy (SPES) measurements. The discharge STEP curves exhibited various peaks consistent with the processes CuO Cu 2 O Cu and with decomposition of the electrolyte, a reversible process in the light of the AFM images. The best electrode exhibited capacity values of 625 Ah kg -1 over more than 100 cycles. This value, which involves a CuO Cu reversible global reaction, is ca. 50% higher than that reported for bulk CuO. The nanosize of the particles and the good adherence of the active material to the substrate are thought to be the key factors accounting for the enhanced electrochemical activity found

  5. Exercise after Stroke: Patient Adherence and Beliefs after Discharge from Rehabilitation.

    Science.gov (United States)

    Miller, Kristine K; Porter, Rebecca E; DeBaun-Sprague, Erin; Van Puymbroeck, Marieke; Schmid, Arlene A

    2017-03-01

    Most people complete post-stroke rehabilitation within the first 6 months after stroke even though benefits from exercise are believed to persist well beyond 6 months. Physical and Occupational therapists provide home exercise programs (HEP) to instruct patients on exercises to continue after discharge from rehabilitation. Unfortunately, there is little known about HEP adherence rates in adults with stroke. The objectives of this project were to (1) determine the adherence rate with post-rehabilitation HEP and reasons for non-adherence, (2) assess for interactions between HEP adherence and self-report of depression and fatigue, and (3) determine patient beliefs about the benefit of exercise during stroke recovery. This was a cross-sectional, survey study. A survey was developed and distributed during stroke support group meetings to determine adherence rates with post rehabilitation HEP, reasons for non-adherence, and patient beliefs about the benefit of exercise. Eighty-nine percent of participants reported receiving a HEP and 65.3% of those reported being adherent with at least part of the HEP. Several reasons for non-adherence were identified, including 'doing different exercises than the ones given by the physical therapist', as the most frequently given reason. Study participants identified positive roles of exercise in their recovery from stroke. Patient adherence with HEP after discharge from rehabilitation is less than ideal. Reasons for non-adherence are varied. Rehabilitation therapists need to be able to identify and help patients manage barriers to HEP adherence to promote management of residual deficits.

  6. Ionic molecular films. Applications. 3. Electron beam stimulated enhanced adherence

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, G; Montereali, R M; Scavarda do Carmo, L C

    1989-11-01

    This paper reports on the advantages of the use of the technique of electron beam lithography to imprint enhanced sensitive patterns on ionic molecular substrates (bulk crystals or films). With this technique, localized superficial defects are produced which change the chemical properties of surfaces. Sensitized surfaces react with absorbates providing enhanced adherence of such substances. The use of spacially controlled electron beams allows the construction of small (sub-micron) feature chemical and very localized enhanced adherence of absorbates.

  7. Probing cellular mechanoadaptation using cell-substrate de-adhesion dynamics: experiments and model.

    Science.gov (United States)

    S S, Soumya; Sthanam, Lakshmi Kavitha; Padinhateeri, Ranjith; Inamdar, Mandar M; Sen, Shamik

    2014-01-01

    Physical properties of the extracellular matrix (ECM) are known to regulate cellular processes ranging from spreading to differentiation, with alterations in cell phenotype closely associated with changes in physical properties of cells themselves. When plated on substrates of varying stiffness, fibroblasts have been shown to exhibit stiffness matching property, wherein cell cortical stiffness increases in proportion to substrate stiffness up to 5 kPa, and subsequently saturates. Similar mechanoadaptation responses have also been observed in other cell types. Trypsin de-adhesion represents a simple experimental framework for probing the contractile mechanics of adherent cells, with de-adhesion timescales shown to scale inversely with cortical stiffness values. In this study, we combine experiments and computation in deciphering the influence of substrate properties in regulating de-adhesion dynamics of adherent cells. We first show that NIH 3T3 fibroblasts cultured on collagen-coated polyacrylamide hydrogels de-adhere faster on stiffer substrates. Using a simple computational model, we qualitatively show how substrate stiffness and cell-substrate bond breakage rate collectively influence de-adhesion timescales, and also obtain analytical expressions of de-adhesion timescales in certain regimes of the parameter space. Finally, by comparing stiffness-dependent experimental and computational de-adhesion responses, we show that faster de-adhesion on stiffer substrates arises due to force-dependent breakage of cell-matrix adhesions. In addition to illustrating the utility of employing trypsin de-adhesion as a biophysical tool for probing mechanoadaptation, our computational results highlight the collective interplay of substrate properties and bond breakage rate in setting de-adhesion timescales.

  8. Determinants of Adherence to Antiretroviral Treatment among HIV ...

    African Journals Online (AJOL)

    This study investigated factors of adherence to Antiretroviral Treatment (ART), factors or variables that can discriminate between adherent and non-adherent patients on ART were selected. Simple structured questionnaire was employed. The study sample consisted of 145 HIV patients who received ART in the Shashemene ...

  9. Lipase immobilized on nanostructured cerium oxide thin film coated on transparent conducting oxide electrode for butyrin sensing

    Energy Technology Data Exchange (ETDEWEB)

    Panky, Sreedevi; Thandavan, Kavitha [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Chemical and Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Sivalingam, Durgajanani [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Electrical and Electronics Engineering, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Sethuraman, Swaminathan; Krishnan, Uma Maheswari [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Chemical and Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Jeyaprakash, Beri Gopalakrishnan [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Electrical and Electronics Engineering, SASTRA University, Thanjavur 613 401, Tamil Nadu (India); Rayappan, John Bosco Balaguru, E-mail: rjbosco@ece.sastra.edu [Centre for Nanotechnology and Advanced Biomaterials (CeNTAB), SASTRA University, Thanjavur 613 401, Tamil Nadu (India); School of Electrical and Electronics Engineering, SASTRA University, Thanjavur 613 401, Tamil Nadu (India)

    2013-01-15

    Nanostructured cerium oxide (CeO{sub 2}) thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique with cerium nitrate salt, Ce(NO{sub 3}){sub 3}{center_dot}6H{sub 2}O as precursor. Fluorine doped cadmium oxide (CdO:F) thin film prepared using spray pyrolysis technique acts as the TCO film and hence the bare electrode. The structural, morphological and elemental characterizations of the films were carried out using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray analysis (EDX) respectively. The diffraction peak positions in XRD confirmed the formation of highly crystalline ceria with cubic structure and FE-SEM images showed uniform adherent films with granular morphology. The band gaps of CeO{sub 2} and TCO were found to be 3.2 eV and 2.6 eV respectively. Lipase enzyme was physisorbed on the surface of CeO{sub 2}/TCO film to form the lipase/nano-CeO{sub 2}/TCO bioelectrode. Sensing studies were carried out using cyclic voltammetry and amperometry, with lipase/nano-CeO{sub 2}/TCO as working electrode and tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33-1.98 mM) with a lowest detection limit of 2 {mu}M with sharp response time of 5 s and a shelf life of about 6 weeks. -- Graphical abstract: Nanostructured cerium oxide thin films were deposited on transparent conducting oxide (TCO) substrate using spray pyrolysis technique. Fluorine doped cadmium oxide (CdO:F) thin film acts as the TCO film and hence the working electrode. Lipase enzyme was physisorbed on the surface of CeO{sub 2}/TCO film and hence the lipase/nano-CeO{sub 2}/TCO bioelectrode has been fabricated. Sensing studies were carried out using cyclic voltammetry and amperometry with tributyrin as substrate. The mediator-free biosensor with nanointerface exhibited excellent linearity (0.33-1.98 mM) with a lowest detection limit of 2 {mu}M with sharp

  10. Microtransfer printing of metal ink patterns onto plastic substrates utilizing an adhesion-controlled polymeric donor layer

    International Nuclear Information System (INIS)

    Park, Ji-Sub; Choi, Jun-Chan; Park, Min-Kyu; Bae, Jeong Min; Bae, Jin-Hyuk; Kim, Hak-Rin

    2016-01-01

    We propose a method for transfer-printed electrode patterns onto flexible/plastic substrates, specifically intended for metal ink that requires a high sintering temperature. Typically, metal-ink-based electrodes cannot be picked up for microtransfer printing because the adhesion between the electrodes and the donor substrate greatly increases after the sintering process due to the binding materials. We introduced a polymeric donor layer between the printed electrodes and the donor substrate and effectively reduced the adhesion between the Ag pattern and the polymeric donor layer by controlling the interfacial contact area. After completing a wet-etching process for the polymeric donor layer, we obtained Ag patterns supported on the fine polymeric anchor structures; the Ag patterns could be picked up onto the stamp surface even after the sintering process by utilizing the viscoelastic properties of the elastomeric stamp with a pick-up velocity control. The proposed method enables highly conductive metal-ink-based electrode patterns to be applied on thermally weak plastic substrates via an all-solution process. Metal electrodes transferred onto a film showed superior electrical and mechanical stability under the bending stress test required for use in printed flexible electronics. (paper)

  11. Effects of treatment adherence on clinical and economic outcomes in patients with psoriasis.

    Science.gov (United States)

    Jevtić, Tatjana; Bukumirić, Zoran; Janković, Slobodan M

    2013-02-01

    To compare clinical and cost outcomes of psoriasis in non-biological treatment of adherent and non-adherent patients in a developing Balkans country going through socio-economic transition. The study was designed as a retrospective cohort study involving patients with psoriasis adherent and non-adherent to the prescribed treatment regimen. The patients were followed for a period of one year, through four visits with intervals of three months. The adherence to the prescribed regimen was measured at the end of the follow-up period by the medication possession ratio. Clinical outcomes of the treatment were estimated by the Psoriasis Area Severity Index (PASI) at each visit and the treatment costs were collected from patients' files at each visit. The study enrolled 108 patients, 61 (56.5%) were adherent to the prescribed treatment, and 47 (43.5%) were non-adherent. A signiicant decrease of PASI score was noted in the patients adherent to prescribed therapy (p drop of costs was the highest from the visit 3. The decrease in PASI score and costs were less rapid in non-adherent patients. Better treatment adherence leads to faster clinical improvement and a more rapid decrease in costs of treatment, which diminish overall expenditure of the health system and society, leaving room for treatment of other diseases more efficiently. Therefore, health systems of developing countries should support additional research of causes of treatment non-adherence in patients with psoriasis, in order to minimize this fenomenon more efficiently, and make significant savings.

  12. Simple and rapid mercury ion selective electrode based on 1-undecanethiol assembled Au substrate and its recognition mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xian-Qing; Liang, Hai-Qing [Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha 410114 (China); Cao, Zhong, E-mail: zhongcao2004@163.com [Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha 410114 (China); Xiao, Qing [Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha 410114 (China); Xiao, Zhong-Liang, E-mail: xiaozhongliang@163.com [Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha 410114 (China); State Key Laboratory of High Performance Complex Manufacturing, School of Mechanical and Electrical Engineering, Central South University, Changsha 410083 (China); Song, Liu-Bin [Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha 410114 (China); Chen, Dan [Hunan Airbluer Environmental Protection Technology Co., Ltd., Changsha 410014 (China); Wang, Fu-Liang [State Key Laboratory of High Performance Complex Manufacturing, School of Mechanical and Electrical Engineering, Central South University, Changsha 410083 (China)

    2017-03-01

    A simple and rapid mercury ion selective electrode based on 1-undecanethiol (1-UDT) assembled Au substrate (Au/1-UDT) has been well constructed. 1-UDT was for the purpose of generating self-assembled monolayer on gold surface to recognize Hg{sup 2+} in aqueous solution, which had a working concentration range of 1.0 × 10{sup −} {sup 8}–1.0 × 10{sup −4} mol L{sup −1}, with a Nernst response slope of 28.83 ± 0.4 mV/-pC, a detection limit of 4.5 × 10{sup −9} mol L{sup −1}, and a good selectivity over the other tested cations. Also, the Au/1-UDT possessed good reproducibility, stability, and short response time. The recovery obtained for the determination of mercury ion in practical tremella samples was in the range of 99.8–103.4%. Combined electrochemical analysis and X-ray photoelectron spectroscopy (XPS) with quantum chemical computation, the probable recognition mechanism of the electrode for selective recognition of Hg{sup 2+} has been investigated. The covalent bond formed between mercury and sulfur is stronger than the one between gold and sulfur and thus prevents the adsorption of 1-UDT molecules on the gold surface. The quantum chemical computation with density functional theory further demonstrates that the strong interaction between the mercury atom and the sulfur atom on the gold surface leads to the gold sulfur bond ruptured and the gold mercury metallophilic interaction. - Highlights: • A simple and rapid mercury ion selective electrode has been well constructed. • The Au/1-UDT electrode for sensing Hg{sup 2+} has a sensitivity of 28.83 ± 0.4 mV/− pC. • The ISE method has a detection limit of Hg{sup 2+} down to 4.5 × 10{sup −9} mol L{sup −1}. • A mechanism with density functional theory for recognition of Hg{sup 2+} is developed. • The quantum chemical computation demonstrates Au-Hg metallophilic interaction.

  13. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording.

    Science.gov (United States)

    Ren, Lei; Xu, Shujia; Gao, Jie; Lin, Zi; Chen, Zhipeng; Liu, Bin; Liang, Liang; Jiang, Lelun

    2018-04-13

    Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode-skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

  14. Information encoded in non-native states drives substrate-chaperone pairing.

    Science.gov (United States)

    Mapa, Koyeli; Tiwari, Satyam; Kumar, Vignesh; Jayaraj, Gopal Gunanathan; Maiti, Souvik

    2012-09-05

    Many proteins refold in vitro through kinetic folding intermediates that are believed to be by-products of native-state centric evolution. These intermediates are postulated to play only minor roles, if any, in vivo because they lack any information related to translation-associated vectorial folding. We demonstrate that refolding intermediate of a test protein, generated in vitro, is able to find its cognate chaperone, from the whole complement of Escherichia coli soluble chaperones. Cognate chaperone-binding uniquely alters the conformation of non-native substrate. Importantly, precise chaperone targeting of substrates are maintained as long as physiological molar ratios of chaperones remain unaltered. Using a library of different chaperone substrates, we demonstrate that kinetically trapped refolding intermediates contain sufficient structural features for precise targeting to cognate chaperones. We posit that evolution favors sequences that, in addition to coding for a functional native state, encode folding intermediates with higher affinity for cognate chaperones than noncognate ones. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Financial incentives to improve adherence to antipsychotic maintenance medication in non-adherent patients: a cluster randomised controlled trial.

    Science.gov (United States)

    Priebe, Stefan; Bremner, Stephen A; Lauber, Christoph; Henderson, Catherine; Burns, Tom

    2016-09-01

    Poor adherence to long-term antipsychotic injectable (LAI) medication in patients with psychotic disorders is associated with a range of negative outcomes. No psychosocial intervention has been found to be consistently effective in improving adherence. To test whether or not offering financial incentives is effective and cost-effective in improving adherence and to explore patient and clinician experiences with such incentives. A cluster randomised controlled trial with economic and nested qualitative evaluation. The intervention period lasted for 12 months with 24 months' follow-up. The unit of randomisation was mental health teams in the community. Community teams in secondary mental health care. Patients with a diagnosis of schizophrenia, schizoaffective psychosis or bipolar illness, receiving ≤ 75% of their prescribed LAI medication. In total, 73 teams with 141 patients (intervention n = 78 and control n = 63) were included. Participants in the intervention group received £15 for each LAI medication. Patients in the control group received treatment as usual. adherence to LAI medication (the percentage of received out of those prescribed). percentage of patients with at least 95% adherence; clinical global improvement; subjective quality of life; satisfaction with medication; hospitalisation; adverse events; and costs. Qualitative evaluation: semistructured interviews with patients in the intervention group and their clinicians. outcome data were available for 131 patients. Baseline adherence was 69% in the intervention group and 67% in the control group. During the intervention period, adherence was significantly higher in the intervention group than in the control group (85% vs. 71%) [adjusted mean difference 11.5%, 95% confidence interval (CI) 3.9% to 19.0%; p = 0.003]. Secondary outcome: patients in the intervention group showed statistically significant improvement in adherence of at least 95% (adjusted odds ratio 8.21, 95% CI 2.00 to 33

  16. Food insecurity is associated with increased risk of non-adherence to antiretroviral therapy among HIV-infected adults in the Democratic Republic of Congo: a cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Patou Masika Musumari

    Full Text Available BACKGROUND: Food insecurity is increasingly reported as an important barrier of patient adherence to antiretroviral therapy (ART in both resource-poor and rich settings. However, unlike in resource rich-settings, very few quantitative studies to date have investigated the association of food insecurity with patient adherence to ART in Sub-Saharan Africa. The current study examines the association between food insecurity and adherence to ART among HIV-infected adults in the Democratic Republic of Congo (DRC. METHODS AND FINDINGS: This is a cross-sectional quantitative study of patients receiving ART at three private and one public health facilities in Kinshasa, DRC. Participants were consecutively recruited into the study between April and November 2012. Adherence was measured using a combined method coupling pharmacy refill and self-reported adherence. Food insecurity was the primary predictor, and was assessed using the Household Food Insecurity Access Scale (HFIAS. Of the 898 participants recruited into the study, 512 (57% were food insecure, and 188 (20.9% were not adherent to ART. Food insecurity was significantly associated with non-adherence to ART (AOR, 2.06; CI, 1.38-3.09. We also found that perceived harmfulness of ART and psychological distress were associated respectively with increased (AOR, 1.95; CI, 1.15-3.32 and decreased (AOR, 0.31; CI, 0.11-0.83 odds of non-adherence to ART. CONCLUSION: Food insecurity is prevalent and a significant risk factor for non-adherence to ART among HIV-infected individuals in the DRC. Our findings highlight the urgent need for strategies to improve food access among HIV-infected on ART in order to ensure patient adherence to ART and ultimately the long-term success of HIV treatment in Sub-Saharan Africa.

  17. Electrical performance of polymer ferroelectric capacitors fabricated on plastic substrate using transparent electrodes

    KAUST Repository

    Bhansali, Unnat Sampatraj

    2012-09-01

    Polymer-based flexible ferroelectric capacitors have been fabricated using a transparent conducting oxide (ITO) and a transparent conducting polymer (PEDOT:PSS). It is found that the polarization fatigue performance with transparent oxide electrodes exhibits a significant improvement over the polymer electrodes (20% vs 70% drop in polarization after 10 6 cycles). This result can be explained based on a charge injection model that is controlled by interfacial band-offsets, and subsequent pinning of ferroelectric domain walls by the injected carriers. Furthermore, the coercive field (E c) of devices with our polymer electrodes is nearly 40% lower than reported values with similar polymer electrodes. Surprisingly, this difference was found to be related to the dry etching process used to define the top electrodes, which is reported for the first time by this group. The temperature dependence of relative permittivity of both devices shows a typical first order ferroelectric-to-paraelectric phase transition, but with a reduced Curie temperature compared to reference devices fabricated on Pt. © 2012 Elsevier B.V. All rights reserved.

  18. Electrical performance of polymer ferroelectric capacitors fabricated on plastic substrate using transparent electrodes

    KAUST Repository

    Bhansali, Unnat Sampatraj; Khan, Yasser; Alshareef, Husam N.

    2012-01-01

    Polymer-based flexible ferroelectric capacitors have been fabricated using a transparent conducting oxide (ITO) and a transparent conducting polymer (PEDOT:PSS). It is found that the polarization fatigue performance with transparent oxide electrodes exhibits a significant improvement over the polymer electrodes (20% vs 70% drop in polarization after 10 6 cycles). This result can be explained based on a charge injection model that is controlled by interfacial band-offsets, and subsequent pinning of ferroelectric domain walls by the injected carriers. Furthermore, the coercive field (E c) of devices with our polymer electrodes is nearly 40% lower than reported values with similar polymer electrodes. Surprisingly, this difference was found to be related to the dry etching process used to define the top electrodes, which is reported for the first time by this group. The temperature dependence of relative permittivity of both devices shows a typical first order ferroelectric-to-paraelectric phase transition, but with a reduced Curie temperature compared to reference devices fabricated on Pt. © 2012 Elsevier B.V. All rights reserved.

  19. Investigating electrochemical removal of bacterial biofilms from stainless steel substrates.

    Science.gov (United States)

    Dargahi, Mahdi; Hosseinidoust, Zeinab; Tufenkji, Nathalie; Omanovic, Sasha

    2014-05-01

    Electrochemical removal of biofilms deserves attention because of its ease of use and environmentally friendly nature. We investigated the influence of electrode potential and treatment time on the removal of a 10-day old Pseudomonas aeruginosa biofilm formed on stainless steel 316 L substrates. At electrode potentials more positive than -1.5 V vs. Ag/AgCl, lower removal rates were observed and only partial removal of the biofilm was achieved during a 1-min time interval. Electrostatic repulsion between the film and electrode surface is believed to drive biofilm detachment under these conditions. However, when the biofilm-coated substrates were treated at potentials negative of -1.5 V vs. Ag/AgCl, complete removal of a biofilm was achieved within seconds. Under these conditions, vigorous evolution of hydrogen gas is believed to be responsible for the film removal, mechanically detaching the bacteria and extracellular polymeric matrix from the substrate. Stainless steel substrates were also subjected to repeated cycles of biofilm formation and electrochemical removal. High removal efficiencies were maintained throughout this process suggesting the potential of the proposed technology for application on conductive surfaces in various industrial settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Medication adherence among adult patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Abdulmalik M Alkatheri

    2014-01-01

    Full Text Available Medication adherence was assessed in 89 patients on hemodialysis (HD at the King Abdul Aziz Medical City using an Arabic version of the Morisky Medication Adherence Scale (MASS-8. The results of the study revealed that 31.46% and 40.45% of the participants showed low and medium adherence, respectively, while 28.09% showed high medication adherence. Accordingly, 71.91% of the patients visiting the dialysis unit were considered medication non-adherent. While being of older age (P = 0.012, being married (P = 0.012 increased the level of adherence, being of medium level of education (P = 0.024 decreased adherence levels. On the other hand, gender, presence of a care-giver, number of members in the household and employment status seems to have no effect on the level of medication adherence. These results call upon the practitioners in HD units to develop intervention programs that can increase the level of medication adherence.

  1. Prevalence, predictors, and clinical consequences of medical adherence in IBD: how to improve it?

    Science.gov (United States)

    Lakatos, Peter Laszlo

    2009-09-14

    Inflammatory bowel diseases (IBD) are chronic diseases with a relapsing-remitting disease course necessitating lifelong treatment. However, non-adherence has been reported in over 40% of patients, especially those in remission taking maintenance therapies for IBD. The economical impact of non-adherence to medical therapy including absenteeism, hospitalization risk, and the health care costs in chronic conditions, is enormous. The causes of medication non-adherence are complex, where the patient-doctor relationship, treatment regimen, and other disease-related factors play key roles. Moreover, subjective assessment might underestimate adherence. Poor adherence may result in more frequent relapses, a disabling disease course, in ulcerative colitis, and an increased risk for colorectal cancer. Improving medication adherence in patients is an important challenge for physicians. Understanding the different patient types, the reasons given by patients for non-adherence, simpler and more convenient dosage regimens, dynamic communication within the health care team, a self-management package incorporating enhanced patient education and physician-patient interaction, and identifying the predictors of non-adherence will help devise suitable plans to optimize patient adherence. This editorial summarizes the available literature on frequency, predictors, clinical consequences, and strategies for improving medical adherence in patients with IBD.

  2. A transparent, solvent-free laminated top electrode for perovskite solar cells

    OpenAIRE

    Makha, Mohammed; Fernandes, Silvia Let?cia; Jenatsch, Sandra; Offermans, Ton; Schleuniger, J?rg; Tisserant, Jean-Nicolas; V?ron, Anna C.; Hany, Roland

    2016-01-01

    Abstract A simple lamination process of the top electrode for perovskite solar cells is demonstrated. The laminate electrode consists of a transparent and conductive plastic/metal mesh substrate, coated with an adhesive mixture of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate), PEDOT:PSS, and sorbitol. The laminate electrode showed a high degree of transparency of 85%. Best cell performance was achieved for laminate electrodes prepared with a sorbitol concentration of ~30 wt% per mil...

  3. Assessing the high frequency behavior of non-polarizable electrodes for spectral induced polarization measurements

    Science.gov (United States)

    Abdulsamad, Feras; Florsch, Nicolas; Schmutz, Myriam; Camerlynck, Christian

    2016-12-01

    During the last decades, the usage of spectral induced polarization (SIP) measurements in hydrogeology and detecting environmental problems has been extensively increased. However, the physical mechanisms which are responsible for the induced polarization response over the usual frequency range (typically 1 mHz to 10-20 kHz) require better understanding. The phase shift observed at high frequencies is sometimes attributed to the so-called Maxwell-Wagner polarization which takes place when charges cross an interface. However, SIP measurements of tap water show a phase shift at frequencies higher than 1 kHz, where no Maxwell-Wagner polarization may occur. In this paper, we enlighten the possible origin of this phase shift and deduce its likely relationship with the types of the measuring electrodes. SIP Laboratory measurements of tap water using different types of measuring electrodes (polarizable and non-polarizable electrodes) are carried out to detect the origin of the phase shift at high frequencies and the influence of the measuring electrodes types on the observed complex resistivity. Sodium chloride is used to change the conductivity of the medium in order to quantify the solution conductivity role. The results of these measurements are clearly showing the impact of the measuring electrodes type on the measured phase spectrum while the influence on the amplitude spectrum is negligible. The phenomenon appearing on the phase spectrum at high frequency (> 1 kHz) whatever the electrode type is, the phase shows an increase compared to the theoretical response, and the discrepancy (at least in absolute value) increases with frequency, but it is less severe when medium conductivity is larger. Additionally, the frequency corner is shifted upward in frequency. The dependence of this phenomenon on the conductivity and the measuring electrodes type (electrode-electrolyte interface) seems to be due to some dielectric effects (as an electrical double layer of small

  4. Furthering patient adherence: A position paper of the international expert forum on patient adherence based on an internet forum discussion

    OpenAIRE

    van Dulmen, Sandra; Sluijs, Emmy; van Dijk, Liset; de Ridder, Denise; Heerdink, Rob; Bensing, Jozien

    2008-01-01

    Abstract Background As the problem of patient non-adherence persists and a solution appears hard to be found, it continues to be important to look for new ways to further the issue. We recently conducted a meta-review of adherence intervention studies which yielded a preliminary agenda for future research, practice and theory development in patient adherence. The objective of the present project was to find out to what extent adherence experts consider this agenda relevant and feasible. Metho...

  5. (110)-Textured Ca-doped BiFeO_3 film on refined Pt(111) electrode layer on glass substrate at reduced temperature

    International Nuclear Information System (INIS)

    Chang, H.W.; Shen, C.Y.; Yuan, F.T.; Tien, S.H.; Lin, S.Y.; Chen, W.A.; Wang, C.R.; Tu, C.S.; Jen, S.U.

    2016-01-01

    Multiferroic and photovoltaic properties of polycrystalline Bi_0_._8_5Ca_0_._1_5FeO_3 (BCFO) film on refined Pt(111) electrode buffered glass substrate have been studied. Optimized Pt(111) electrode layer having large grain size and smooth morphology enables the development of highly (110)-textured BCFO film at a temperature as low as 450 °C. The prepared BCFO film has dense microstructure, fine grain size, and smooth surface morphology. Good ferroelectric properties with the remanent polarization (2P_r) of 108 μC/cm"2 and electrical coercive field of 405 kV/cm are achieved. Improved ferromagnetic properties with magnetization of 9.2 emu/cm"3 and coercivity of 1250 Oe are also attained. Significant PV properties with open-circuit photovoltage of 0.49 V and the short-circuit photocurrent of 67.4 μA/cm"2 at illumination intensity of 228 mW/cm"2 are observed, which are comparable to BCFO ceramics or BFO epitaxial films. - Highlights: • BCFO polycrystalline film with (110) texture is formed on Pt(111) electrode. • Pt(111) underlayer induces BCFO(110) film with fine grain and flat surface. • Good multiferroic and photovoltaic properties are achieved simultaneously. • Improved multiferroic and photovoltaic properties makes BCFO film a multifunctional material for advanced applications.

  6. Surface modification of recording electrodes

    Directory of Open Access Journals (Sweden)

    Iaci Miranda Pereira

    2013-01-01

    Full Text Available Waterborne Polyurethanes (PUs are a family of polymers that contains urethane linkages synthesized in an aqueous environment and are thus free of organic solvents. Recently, waterborne PUs have been extensively studied for biomedical applications because of their biocompatibility. The present work investigates the following: (1 the impact on electrical performance of electrode materials (platinum and silicon modified chemically by a layer of waterborne PU, and (2 the behavior of rat cardiac fibroblasts and rat cardiomyocytes when in contact with an electrode surface. Diisocyanate and poly(caprolactone diol were the main reagents for producing PUs. The electrochemical impedance of the electrode/electrolyte interface was accessed by electrochemical impedance spectroscopy. The cellular viability, proliferation, and morphology changes were investigated using an MTT assay. Cardiomyocyte adherence was observed by scanning electron microscopy. The obtained surface was uniform, flat, and transparent. The film showed good adhesion, and no peeling was detected. The electrochemical impedance decreased over time and was influenced by the ionic permeability of the PU layer. The five samples did not show cytotoxicity when in contact with neonatal rat cells.

  7. Validating the Modified Drug Adherence Work-Up (M-DRAW) Tool to Identify and Address Barriers to Medication Adherence.

    Science.gov (United States)

    Lee, Sun; Bae, Yuna H; Worley, Marcia; Law, Anandi

    2017-09-08

    Barriers to medication adherence stem from multiple factors. An effective and convenient tool is needed to identify these barriers so that clinicians can provide a tailored, patient-centered consultation with patients. The Modified Drug Adherence Work-up Tool (M-DRAW) was developed as a 13-item checklist questionnaire to identify barriers to medication adherence. The response scale was a 4-point Likert scale of frequency of occurrence (1 = never to 4 = often). The checklist was accompanied by a GUIDE that provided corresponding motivational interview-based intervention strategies for each identified barrier. The current pilot study examined the psychometric properties of the M-DRAW checklist (reliability, responsiveness and discriminant validity) in patients taking one or more prescription medication(s) for chronic conditions. A cross-sectional sample of 26 patients was recruited between December 2015 and March 2016 at an academic medical center pharmacy in Southern California. A priming question that assessed self-reported adherence was used to separate participants into the control group of 17 "adherers" (65.4%), and into the intervention group of nine "unintentional and intentional non-adherers" (34.6%). Comparable baseline characteristics were observed between the two groups. The M-DRAW checklist showed acceptable reliability (13 item; alpha = 0.74) for identifying factors and barriers leading to medication non-adherence. Discriminant validity of the tool and the priming question was established by the four-fold number of barriers to adherence identified within the self-selected intervention group compared to the control group (4.4 versus 1.2 barriers, p tool will include construct validation.

  8. Scanning electrochemical microscopy. 47. Imaging electrocatalytic activity for oxygen reduction in an acidic medium by the tip generation-substrate collection mode.

    Science.gov (United States)

    Fernández, José L; Bard, Allen J

    2003-07-01

    The oxygen reduction reaction (ORR) in acidic medium was studied on different electrode materials by scanning electrochemical microscopy (SECM) operating in a new variation of the tip generation-substrate collection mode. An ultramicroelectrode tip placed close to the substrate electrode oxidizes water to oxygen at a constant current. The substrate is held at a potential where the tip-generated oxygen is reduced and the resulting substrate current is measured. By changing the substrate potential, it is possible to obtain a polarization (current-potential) curve, which depends on the electrocatalytic activity of the substrate material. The main difference between this mode and the classical feedback SECM mode of operation is that the feedback diffusion process is not required for the measurement, allowing its application for studying the ORR in acidic solutions. Activity-sensitive images of heterogeneous surfaces, e.g., with Pt and Au electrodes, were obtained from the substrate current when the x-y plane was scanned with the tip. The usefulness of this technique for imaging electrocatalytic activity of smooth metallic electrodes and of highly dispersed fuel cell-type electrocatalysts was demonstrated. The application of this method to the combinatorial chemical analysis of electrode materials and electrocatalysts is discussed.

  9. Global consequences of a local Casimir force : Adhered cantilever

    NARCIS (Netherlands)

    Svetovoy, V. B.; Melenev, A. E.; Lokhanin, M. V.; Palasantzas, G.

    2017-01-01

    Although stiction is a cumbersome problem for microsystems, it stimulates investigations of surface adhesion. In fact, the shape of an adhered cantilever carries information of the adhesion energy that locks one end to the substrate. We demonstrate here that the system is also sensitive to the

  10. [Improving treatment adherence in kidney transplantation: a major challenge].

    Science.gov (United States)

    Kessler, Michèle

    2014-06-01

    The kidney transplant recipient is faced not only with the perspective of taking immunosuppressive drugs lifelong, but also the possibility of other long-term treatments prescribed for preexisting conditions, complications, or side effects. Proper management, and most importantly patient adherence, can become a complex challenge. Here we recall current definitions and describe methods for measuring treatment adherence, followed by a discussion on the prevalence of non-adherence in kidney transplant recipients, its effect on graft survival, and factors predictive of non-adherence. Ways of improving adherence are examined, leading to the conviction that helping patients take their medications regularly would probably have a greater impact on graft survival than marketing a new immunosuppressive agent. Copyright © 2014 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  11. Liquid-phase synthesis of vertically aligned carbon nanotubes and related nanomaterials on preheated alloy substrates

    Science.gov (United States)

    Yamagiwa, Kiyofumi

    2018-02-01

    Carbon nanotubes (CNTs) and related nanocarbons were selectively synthesized on commercially available alloy substrates by a simple liquid-phase technique. Fe- and Ni-rich stainless-steel (JIS SUS316L and Inconel®600, respectively) and Ni-Cu alloy (Monel®400) substrates were used for the synthesis, and each substrate was preheated in air to promote the self-formation of catalyst nanolayers on the surface. The substrates were resistance heated in ethanol without any addition of catalysts to grow CNTs. The yield of the CNTs effectively increased when the preheating process was employed. Highly aligned CNT arrays grew on the SUS316L substrate, while non-aligned CNTs and distinctive twisted fibers were observed on the other substrates. An Fe oxide layer was selectively formed on the preheated SUS316L substrate promoting the growth of the CNT arrays. Characterizations including cyclic voltammetry for the arrays revealed that the CNTs possess a comparatively defect-rich surface, which is a desirable characteristic for its application such as electrode materials for capacitors.

  12. Enhanced control of electrochemical response in metallic materials in neural stimulation electrode applications

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, K.G.; Steen, W.M.; Manna, I. [Univ. of Liverpool (United Kingdom)] [and others

    1996-12-31

    New means have been investigated for the production of electrode devices (stimulation electrodes) which could be implanted in the human body in order to control pain, activate paralysed limbs or provide electrode arrays for cochlear implants for the deaf or for the relief of tinitus. To achieve this ion implantation and laser materials processing techniques were employed. Ir was ion implanted in Ti-6Al-4V alloy and the surface subsequently enriched in the noble metal by dissolution in sulphuric acid. For laser materials processing techniques, investigation has been carried out on the laser cladding and laser alloying of Ir in Ti wire. A particular aim has been the determination of conditions required for the formation of a two phase Ir, Ir-rich, and Ti-rich microstructure which would enable subsequent removal of the non-noble phase to leave a highly porous noble metal with large real surface area and hence improved charge carrying capacity compared with conventional non porous electrodes. Evaluation of the materials produced has been carried out using repetitive cyclic voltammetry, amongst other techniques. For laser alloyed Ir on Ti wire, it has been found that differences in the melting point and density of the materials makes control of the cladding or alloying process difficult. Investigation of laser process parameters for the control of alloying and cladding in this system was carried out and a set of conditions for the successful production of two phase Ir-rich and Ti-rich components in a coating layer with strong metallurgical bonding to the Ti alloy substrate was derived. The laser processed material displays excellent potential for further development in providing stimulation electrodes with the current carrying capacity of Ir but in a form which is malleable and hence capable of formation into smaller electrodes with improved spatial resolution compared with presently employed electrodes.

  13. Patient survey to identify reasons for non-adherence and elicitation of quality of life concepts associated with immunosuppressant therapy in kidney transplant recipients.

    Science.gov (United States)

    Muduma, Gorden; Shupo, Francis C; Dam, Sophie; Hawken, Natalia A; Aballéa, Samuel; Odeyemi, Isaac; Toumi, Mondher

    2016-01-01

    Renal transplantation (RT) is considered the treatment of choice for end-stage renal disease compared to dialysis, offering better health-related quality of life (HRQoL) and higher survival rates. However, immunosuppressants are essential for the long-term survival of kidney grafts and patients' non-adherence to their medication leads to poor outcomes. Immunosuppressants can also significantly alter patients' HRQoL because of their side effects and the complex chronic medication regimen they represent. To elicit key concepts related to adherence to immunosuppressant therapy (IT) and reasons for non-adherence in terms of patient reported outcomes, side effects, and the impact of the medication on HRQoL in RT population, including patient preference of once daily over twice-daily immunosuppressive regimen. Results were used to develop an IT-specific conceptual framework and provide suggestions for improving patients' adherence to IT. Interviews were conducted with three clinical experts to determine key concepts related to RT and immunosuppressants. Thirty-seven participants in four focus groups were asked to cite important concepts related to adherence and impact of IT on HRQoL and to rate them. Qualitative analysis was conducted to code participants' responses. Non-adherence among participants where admitted was unintentional. The reason for this included forgetfulness, interference with lifestyle, being asleep at the time the medication should be taken, change in routine, and impact of side effects. Overall, participants reported that the evening dose was more problematic to remember and that the exclusion of this dose could make them more adherent. Participants also reported that IT impacted on their HRQoL in a number of ways including: placing restrictions on their lifestyle, causing anxiety, or impairing their ability to work. This study provides qualitative evidence about the barriers to IT adherence and the components of HRQoL that are important from the

  14. AAO-CNTs electrode on microfluidic flow injection system for rapid iodide sensing.

    Science.gov (United States)

    Phokharatkul, Ditsayut; Karuwan, Chanpen; Lomas, Tanom; Nacapricha, Duangjai; Wisitsoraat, Anurat; Tuantranont, Adisorn

    2011-06-15

    In this work, carbon nanotubes (CNTs) nanoarrays in anodized aluminum oxide (AAO-CNTs) nanopore is integrated on a microfluidic flow injection system for in-channel electrochemical detection of iodide. The device was fabricated from PDMS (polydimethylsiloxane) microchannel bonded on glass substrates that contains three-electrode electrochemical system, including AAO-CNTs as a working electrode, silver as a reference electrode and platinum as an auxiliary electrode. Aluminum, stainless steel catalyst, silver and platinum layers were sputtered on the glass substrate through shadow masks. Aluminum layer was then anodized by two-step anodization process to form nanopore template. CNTs were then grown in AAO template by thermal chemical vapor deposition. The amperometric detection of iodide was performed in 500-μm-wide and 100-μm-deep microchannels on the microfluidic chip. The influences of flow rate, injection volume and detection potential on the current response were optimized. From experimental results, AAO-CNTs electrode on chip offers higher sensitivity and wider dynamic range than CNTs electrode with no AAO template. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. The reversal constituent structure of photo-electrode in dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Ting, Chen-Ching; Chao, Wei-Shi

    2011-01-01

    Highlights: → The new structure of photo-electrode in DSSC increases absorption of incident photons. → The substrate of copper mesh as photo-electrode reduces electric resistance. → Application of the copper mesh as substrate reduces the fabricating cost. → There are ca. 3 times increment of photoelectric conversion efficiency. → Application of the copper mesh as substrate can achieve the flexible DSSCs. - Abstract: This article presents significant experimental data about the dye-sensitized nano solar cells (DSSCs) using the new developed photo-electrode with reversal constituent structure in our CCT laboratory. The conventional constituent structure of a photo-electrode arranged in sequence from the incident light is the transparent conductive glass, the nano TiO 2 semi-conductive porous film, and the dye. In process, the photons energy of the incident light is mainly absorbed by the dye for DSSCs. This causes excited electrons in the dye to jump into conductive band of the TiO 2 and further to transfer into the outer circuit through the conductive glass. That is, a correct constituent structure of the photo-electrode arranged in sequence from the incident light in terms of the working principle should be the dye, the nano TiO 2 film, and the conductive substrate. The conventional constituent structure of the photo-electrode causes the incident light to be hindered by the TiO 2 layer. To reduce the light hindrance for the dye, this work used copper mesh as the conductive substrate and the nano TiO 2 was coated on it. In this way, the copper mesh connects the nano TiO 2 layer with the outer circuit and the holes of the copper mesh also allow the dye to contact with the electrolyte. The new developed constituent structure of the photo-electrode arranged in sequence from the incident light is the dye, the nano TiO 2 film, and the copper mesh. This new constituent structure, which increases amounts of the absorption light in the dye and further improved the

  16. 3D integration of planar crossbar memristive devices with CMOS substrate

    International Nuclear Information System (INIS)

    Lin, Peng; Pi, Shuang; Xia, Qiangfei

    2014-01-01

    Planar memristive devices with bottom electrodes embedded into the substrates were integrated on top of CMOS substrates using nanoimprint lithography to implement hybrid circuits with a CMOL-like architecture. The planar geometry eliminated the mechanically and electrically weak parts, such as kinks in the top electrodes in a traditional crossbar structure, and allowed the use of thicker and thus less resistive metal wires as the bottom electrodes. Planar memristive devices integrated with CMOS have demonstrated much lower programing voltages and excellent switching uniformity. With the inclusion of the Moiré pattern, the integration process has sub-20 nm alignment accuracy, opening opportunities for 3D hybrid circuits in applications in the next generation of memory and unconventional computing. (paper)

  17. Electrode-immobilized compounds through γ radiation

    International Nuclear Information System (INIS)

    De Castro, E.S.

    1983-01-01

    Chemically Modified Electrodes (CMEs) are used as substrates in heterogeneous catalysis and as sensors. This work demonstrates a new strategy for immobilizing polyelectrolytes and electroactive agents on electrode surfaces. The success of this method lies in cross-linking water soluble polymer chains through the ionizing radiation of γ emissions from a 60 Co source. Cross-linking can create a continuous network out of the polymer macromolecules which then makes the network insoluble on the electrode surface. Bonds between the network and the substrate are also possible. Redox species mixed with the polymer network and irradiated become part of the insoluble network, and are permanently attached. The use of γ radiation to make electrochemical sensors is demonstrated. The immobilized network poly[diallyl dimethyl ammonium chloride] (DDAC) is placed in a solution of potassium ferricyanide and ionicly exchanges the anion into the network. An electroactive network is created from irradiating a mixture of DDAC and 2,6-dichlorophenolindophenol (DCIP). Using the amount of electroactive DCIP remaining in the film as the optimization parameter, variables such as polymer:DCIP ratio, film thickness, and dosage employed are shown to be relevant

  18. Association between adherence to medications for COPD and medications for other chronic conditions in COPD patients

    Directory of Open Access Journals (Sweden)

    Dhamane AD

    2016-12-01

    Full Text Available Amol D Dhamane,1 Phil Schwab,2 Sari Hopson,2 Chad Moretz,2 Srinivas Annavarapu,2 Kate Burslem,1 Andrew Renda,3 Shuchita Kaila1 1Health Economics and Outcomes Research, Boehringer Ingelheim Pharmaceuticals Inc, Ridgefield, CT, 2Comprehensive Health Insights Inc, Louisville, 3Humana Inc, Louisville, KY, USA Background: Patients with COPD often have multiple comorbidities requiring use of multiple medications, and adherence rates for maintenance COPD (mCOPD medications are already known to be suboptimal. Presence of comorbidities in COPD patients, and use of medications used to treat those comorbidities (non-COPD medications, may have an adverse impact on adherence to mCOPD medications. Objective: The objective of the study was to evaluate the association between non-adherence to mCOPD medications and non-COPD medications in COPD patients. Methods: COPD patients were identified using a large administrative claims database. Selected patients were 40–89 years old and continuously enrolled for 12 months prior to and 24 months after the first identified COPD diagnosis (index date during January 1, 2009 to December 31, 2010. Patients were required to have ≥1 prescription for a mCOPD medication within 365 days of the index date and ≥1 prescription for one of 12 non-COPD medication classes within ±30 days of the first COPD prescription. Adherence (proportion of days covered [PDC] was measured during 365 days following the first COPD prescription. The association between non-adherence (PDC <0.8 to mCOPD and non-adherence to non-COPD medications was determined using logistic regression, controlling for baseline patient characteristics. Results: A total of 14,117 patients, with a mean age of 69.9 years, met study criteria. Of these, 40.9% were males and 79.2% were non-adherent to mCOPD medications with a mean PDC of 0.47. Non-adherence to mCOPD medications was associated with non-adherence to 10 of 12 non-COPD medication classes (odds ratio 1.38–1

  19. Adherence to the Mediterranean diet pattern, cognitive status and depressive symptoms in an elderly non-institutionalized population.

    Science.gov (United States)

    Hernández-Galiot, Ana; Goñi, Isabel

    2017-03-30

    Scientific evidence indicates that adherence to the Mediterranean diet protects against the deterioration of cognitive status and depressive symptoms during aging. However, few studies have been conducted in elderly non-institutionalized subjects. This study evaluated the relation between the adherence to the Mediterranean dietary pattern and cognitive status and depressive symptoms in an elderly population over 75 years. A cross-sectional study was conducted in a Mediterranean city (Garrucha, Spain) in 79 elderly people over 75 (36 men and 41 women). Adherence to the Mediterranean dietary pattern was determined using the Mediterranean Diet Adherence Screener (MEDAS). Cognitive function was determined by the Mini Mental State Examination (MMSE), and depressive symptoms were assessed by the Geriatric Depression Scale (GDS). Most of population showed a very high adherence to the Mediterranean diet pattern and optimal cognitive and affective status. They consumed olive oil as their main source of fat, high levels of fish and fruit, low levels of foods with added sugars, and a low consumption of red meat. A significant relation between the MEDAS and MMSE scores was found. However, no relationship was observed between the MEDAS and GDS. The Mediterranean diet pattern was positively related with the cognitive function, although the infl uence of a healthy dietary pattern on the symptomatology of depression was unclear. However, an effective strategy against cognitive function and depression would be to improve physical activity rates, establish lifelong healthy eating habits, and consume a nutritionally-rich diet in order to enhance quality of life of the elderly.

  20. Comparative study on polyvinyl chloride film as flexible substrate for preparing free-standing polyaniline-based composite electrodes for supercapacitors.

    Science.gov (United States)

    Wang, Hongxing; Liu, Dong; Du, Pengcheng; Wei, Wenli; Wang, Qi; Liu, Peng

    2017-11-15

    The free-standing polyaniline (PANI)-based composite film electrodes were prepared with polyvinyl chloride (PVC) and the aniline modified PVC (PVC-An) films as flexible substrates for supercapacitors, via facile in-situ chemical oxidative polymerization of aniline, with conventional chemical oxidative polymerization or rapid-mixing chemical oxidative polymerization technique. Owing to the grafting of PANI from the PVC-An film as substrate and the suppression of the secondary growth of the primary PANI particles in the rapid-mixing chemical oxidative polymerization, the PVC-g-PANI-2 composite film with loose surface possessed better comprehensive performance, accompanying the high specific capacitance (645.3F/g at a current density of 1A/g), good rate capacitance (retaining 63.2% of original value at a current density of 10A/g and 52.0% at a scan rate of 100mV/s), good cycle stability (retaining 83.1% after 1000 cycles) and the improved internal resistance. Besides its excellent flexibility, it could retain 61.2% of its original specific capacitance under the stress of 8.66MPa for 1h, demonstrating a good tensile-resistance. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Natural cellulose fiber as substrate for supercapacitor.

    Science.gov (United States)

    Gui, Zhe; Zhu, Hongli; Gillette, Eleanor; Han, Xiaogang; Rubloff, Gary W; Hu, Liangbing; Lee, Sang Bok

    2013-07-23

    Cellulose fibers with porous structure and electrolyte absorption properties are considered to be a good potential substrate for the deposition of energy material for energy storage devices. Unlike traditional substrates, such as gold or stainless steel, paper prepared from cellulose fibers in this study not only functions as a substrate with large surface area but also acts as an interior electrolyte reservoir, where electrolyte can be absorbed much in the cellulose fibers and is ready to diffuse into an energy storage material. We demonstrated the value of this internal electrolyte reservoir by comparing a series of hierarchical hybrid supercapacitor electrodes based on homemade cellulose paper or polyester textile integrated with carbon nanotubes (CNTs) by simple solution dip and electrodeposited with MnO2. Atomic layer deposition of Al2O3 onto the fiber surface was used to limit electrolyte absorption into the fibers for comparison. Configurations designed with different numbers of ion diffusion pathways were compared to show that cellulose fibers in paper can act as a good interior electrolyte reservoir and provide an effective pathway for ion transport facilitation. Further optimization using an additional CNT coating resulted in an electrode of paper/CNTs/MnO2/CNTs, which has dual ion diffusion and electron transfer pathways and demonstrated superior supercapacitive performance. This paper highlights the merits of the mesoporous cellulose fibers as substrates for supercapacitor electrodes, in which the water-swelling effect of the cellulose fibers can absorb electrolyte, and the mesoporous internal structure of the fibers can provide channels for ions to diffuse to the electrochemical energy storage materials.

  2. Factors influencing long-term adherence to two previously implemented hospital guidelines

    NARCIS (Netherlands)

    Knops, A. M.; Storm-Versloot, M. N.; Mank, A. P. M.; Ubbink, D. T.; Vermeulen, H.; Bossuyt, P. M. M.; Goossens, A.

    2010-01-01

    After successful implementation, adherence to hospital guidelines should be sustained. Long-term adherence to two hospital guidelines was audited. The overall aim was to explore factors accounting for their long-term adherence or non-adherence. A fluid balance guideline (FBG) and body temperature

  3. Amino acid derivatives are substrates or non-transported inhibitors of the amino acid transporter PAT2 (slc36a2).

    Science.gov (United States)

    Edwards, Noel; Anderson, Catriona M H; Gatfield, Kelly M; Jevons, Mark P; Ganapathy, Vadivel; Thwaites, David T

    2011-01-01

    The H(+)-coupled amino acid transporter PAT2 (SLC36A2) transports the amino acids proline, glycine, alanine and hydroxyproline. A physiological role played by PAT2 in amino acid reabsorption in the renal proximal tubule is demonstrated by mutations in SLC36A2 that lead to an iminoglycinuric phenotype (imino acid and glycine uria) in humans. A number of proline, GABA and tryptophan derivatives were examined to determine if they function either as transported substrates or non-transported inhibitors of PAT2. The compounds were investigated following heterologous expression of rat PAT2 in Xenopus laevis oocytes. PAT2 function was characterised by: radiotracer uptake and competition (cis-inhibition) studies; radiotracer efflux and trans-stimulation; and measurement of substrate-induced positive inward current by two-electrode voltage-clamp. In general, the proline derivatives appeared to be transported substrates and the relative ability to induce current flow was closely related to the inhibitory effects on PAT2-mediated l-[(3)H]proline uptake. In contrast, certain heterocyclic GABA derivatives (e.g. l-pipecolic acid) were translocated only slowly. Finally, the tryptophan derivatives inhibited PAT2 function but did not undergo transport. l-Proline uptake was inhibited by 5-hydroxy-l-tryptophan (IC(50) 1.6±0.4mM), α-methyl-d,l-tryptophan (3.5±1.5mM), l-tryptophan, 1-methyl-l-tryptophan and indole-3-propionic acid. Although neither 5-hydroxy-l-tryptophan nor α-methyl-d,l-tryptophan were able to elicit inward current in PAT2-expressing oocytes both reduced the current evoked by l-proline. 5-Hydroxy-l-tryptophan and α-methyl-d,l-tryptophan were unable to trans-stimulate l-proline efflux from PAT2-expressing oocytes, confirming that the two compounds act as non-transported blockers of PAT2. These two tryptophan derivatives should prove valuable experimental tools in future investigations of the physiological roles of PAT2. Copyright © 2010 Elsevier B.V. All rights

  4. Fully solution-processed organic solar cells on metal foil substrates

    KAUST Repository

    Gaynor, Whitney

    2009-08-19

    We demonstrate fully solution-processed organic photovoltaic cells on metal foil substrates with power conversion efficiencies similar to those obtained in devices on transparent substrates. The cells are based on the regioregular poly- (3-hexylthiophene) and C61 butyric acid methyl ester bulk heterojunction system. The bottom electrode is a silver film whose workfunction is lowered by Cs2CO3 using spin-coating to serve as a cathode. The transparent top anode consists of a conductive polymer in combination with a solution-processed silver nanowire mesh that is laminated onto the devices. Each layer of the device, including the transparent electrode, is fabricated from solution, giving rise to the possibility of completely printed solar cells on low-cost substrates.

  5. Understanding how adherence goals promote adherence behaviours: a repeated measure observational study with HIV seropositive patients

    Directory of Open Access Journals (Sweden)

    Jones Gareth

    2012-08-01

    Full Text Available Abstract Background The extent to which patients follow treatments as prescribed is pivotal to treatment success. An exceptionally high level (> 95% of HIV medication adherence is required to suppress viral replication and protect the immune system and a similarly high level (> 80% of adherence has also been suggested in order to benefit from prescribed exercise programmes. However, in clinical practice, adherence to both often falls below the desirable level. This project aims to investigate a wide range of psychological and personality factors that may lead to adherence/non-adherence to medical treatment and exercise programmes. Methods HIV positive patients who are referred to the physiotherapist-led 10-week exercise programme as part of the standard care are continuously recruited. Data on social cognitive variables (attitude, intention, subjective norms, self-efficacy, and outcome beliefs about the goal and specific behaviours, selected personality factors, perceived quality of life, physical activity, self-reported adherence and physical assessment are collected at baseline, at the end of the exercise programme and again 3 months later. The project incorporates objective measures of both exercise (attendance log and improvement in physical measures such as improved fitness level, weight loss, improved circumferential anthropometric measures and medication adherence (verified by non-invasive hair analysis. Discussion The novelty of this project comes from two key aspects, complemented with objective information on exercise and medication adherence. The project assesses beliefs about both the underlying goal such as following prescribed treatment; and about the specific behaviours such as undertaking the exercise or taking the medication, using both implicit and explicit assessments of patients’ beliefs and attitudes. We predict that i the way people think about the underlying goal of their treatments explains medication and exercise

  6. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    Science.gov (United States)

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  7. Recent Developments of Nanostructured Electrodes for Bioelectrocatalysis of Dioxygen Reduction

    Directory of Open Access Journals (Sweden)

    Marcin Opallo

    2011-01-01

    Full Text Available The recent development of nanostructured electrodes for bioelectrocatalytic dioxygen reduction catalysed by two copper oxidoreductases, laccase and bilirubin oxidase, is reviewed. Carbon-based nanomaterials as carbon nanotubes or carbon nanoparticles are frequently used for electrode modification, whereas there are only few examples of biocathodes modified with metal or metal oxide nanoparticles. These nanomaterials are adsorbed on the electrode surface or embedded in multicomponent film. The nano-objects deposited act as electron shuttles between the enzyme and the electrode substrate providing favourable conditions for mediatorless bioelectrocatalysis.

  8. Correlates of Pediatric CPAP Adherence

    Science.gov (United States)

    Hawkins, Stephen M.M.; Jensen, Emily L.; Simon, Stacey L.; Friedman, Norman R.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is a common pediatric condition characterized by recurrent partial or complete cessation of airflow during sleep, typically due to inadequate upper airway patency. Continuous positive airway pressure (CPAP) is a therapeutic option that reduces morbidity. Despite efforts to promote use, CPAP adherence is poor in both pediatric and adult populations. We sought to determine whether demographics, insurance status, OSA severity, therapeutic pressure, or comorbid conditions were associated with pediatric CPAP adherence. Methods: A retrospective review of adherence download data was performed on all pediatric patients with initiation or adjustment of CPAP treatment over a one-year period with documented in-laboratory CPAP titration. Patients were grouped as CPAP adherent or non-adherent, where adherence was defined as > 70% nightly use and average usage ≥ 4 hours per night. Differences between the groups were analyzed by χ2 test. Results: Overall, nearly half of participants were CPAP adherent (49%, 69/140). Of the demographic data collected (age, ethnicity, sex, insurance status), only female sex was associated with better adherence (60.9% vs 39.5% of males adherent; odds ratio [OR] = 2.41, 95%CI = 1.20–4.85; p = 0.01). Severity of OSA (diagnostic apnea-hypopnea index [AHI] and degree of hypoxemia), therapeutic pressure, and residual AHI did not impact CPAP adherence (p > 0.05). Patients with developmental delay (DD) were more likely to be adherent with CPAP than those without a DD diagnosis (OR = 2.55, 95%CI = 1.27–5.13; p = 0.007). Female patients with trisomy 21 tended to be more adherent, but this did not reach significance or account for the overall increased adherence associated with female sex. Conclusions: Our study demonstrates that adherence to CPAP therapy is poor but suggests that female sex and developmental delay are associated with better adherence. These findings support efforts to understand the

  9. Feeding in full-time public schools: Do students adhere and accept?

    Directory of Open Access Journals (Sweden)

    Nágila Araújo de CARVALHO

    Full Text Available ABSTRACT Objective Identifying adherence to, and acceptance of school feeding, and analyzing the factors associated with non-adherence/non-acceptance in full-time public schools in Goiânia, Goiás, Brazil. Methods Cross-sectional study with students of both sexes aged 6-14 years. Issues regarding the consumption of meals, food distribution, food eaten outside the school and socioeconomic data, including nutritional assessment of students, were investigated. Adherence to meals was defined as the consumption of school meals four to five times/week, and acceptance was defined as meal approval, using the facial hedonic scale. Results A total of 359 students participated in this study and it was observed that adherence was high for lunch (95% and afternoon snacks (78%, and low for morning snacks (44%. Acceptance did not reach the required minimum percentage of 85% for any of the meals. Factors associated with non-adherence were the presence of >4 people in a household, having meals in a refectory, the meal location being considered uncomfortable and a negative evaluation of utensils used in eating meals. Factors associated with non-acceptance were age >10 years, female sex, the negative evaluation of utensils used in eating meals and inadequate food temperature. Conclusion Lunch and afternoon snacks showed the highest adherence, but the stipulated acceptance was not reached. Non-adherence and non-acceptance were mainly associated with aspects related to school feeding. This study allowed the evaluation of feeding in full-time public schools, in order to influence its improvement.

  10. Optimizing adherence in HIV prevention product trials: Development and psychometric evaluation of simple tools for screening and adherence counseling.

    Science.gov (United States)

    Tolley, Elizabeth E; Guthrie, Kate Morrow; Zissette, Seth; Fava, Joseph L; Gill, Katherine; Louw, Cheryl E; Kotze, Philip; Reddy, Krishnaveni; MacQueen, Kathleen

    2018-01-01

    Low adherence in recent HIV prevention clinical trials highlights the need to better understand, measure, and support product use within clinical trials. Conventional self-reported adherence instruments within HIV prevention trials, often relying on single-item questions, have proven ineffective. While objective adherence measures are desirable, none currently exist that apply to both active and placebo arms. Scales are composed of multiple items in the form of questions or statements that, when combined, measure a more complex construct that may not be directly observable. When psychometrically validated, such measures may better assess the multiple factors contributing to adherence/non-adherence. This study aimed to develop and psychometrically evaluate tools to screen and monitor trial participants' adherence to HIV prevention products within the context of clinical trial research. Based on an extensive literature review and conceptual framework, we identified and refined 86 items assessing potential predictors of adherence and 48 items assessing adherence experience. A structured survey, including adherence items and other variables, was administered to former ASPIRE and Ring Study participants and similar non-trial participants (n = 709). We conducted exploratory factor analyses (EFA) to identify a reduced set of constructs and items that could be used at screening to predict potential adherence, and at follow-up to monitor and intervene on adherence. We examined associations with other variables to assess content and construct validity. The EFA of screener items resulted in a 6-factor solution with acceptable to very good internal reliability (α: .62-.84). Similar to our conceptual framework, factors represent trial-related commitment (Distrust of Research and Commitment to Research); alignment with trial requirements (Visit Adherence and Trial Incompatibility); Belief in Trial Benefits and Partner Disclosure. The EFA on monitoring items resulted in 4

  11. Factors influencing adherence to routine iron supplementation ...

    African Journals Online (AJOL)

    Anemia in pregnancy is a common problem especially in developing countries. and has been linked with feotal and maternal complications. Taking iron supplements could reduce anaemia in pregnancy but some pregnant women do not adhere to this. The study identified some factors associated with non adherence ...

  12. Composite carbon foam electrode

    Science.gov (United States)

    Mayer, Steven T.; Pekala, Richard W.; Kaschmitter, James L.

    1997-01-01

    Carbon aerogels used as a binder for granularized materials, including other forms of carbon and metal additives, are cast onto carbon or metal fiber substrates to form composite carbon thin film sheets. The thin film sheets are utilized in electrochemical energy storage applications, such as electrochemical double layer capacitors (aerocapacitors), lithium based battery insertion electrodes, fuel cell electrodes, and electrocapacitive deionization electrodes. The composite carbon foam may be formed by prior known processes, but with the solid particles being added during the liquid phase of the process, i.e. prior to gelation. The other forms of carbon may include carbon microspheres, carbon powder, carbon aerogel powder or particles, graphite carbons. Metal and/or carbon fibers may be added for increased conductivity. The choice of materials and fibers will depend on the electrolyte used and the relative trade off of system resistivty and power to system energy.

  13. Modelling of Amperometric Biosensor Used for Synergistic Substrates Determination

    Directory of Open Access Journals (Sweden)

    Dainius Simelevicius

    2012-04-01

    Full Text Available In this paper the operation of an amperometric biosensor producing a chemically amplified signal is modelled numerically. The chemical amplification is achieved by using synergistic substrates. The model is based on non-stationary reaction-diffusion equations. The model involves three layers (compartments: a layer of enzyme solution entrapped on the electrode surface, a dialysis membrane covering the enzyme layer and an outer diffusion layer which is modelled by the Nernst approach. The equation system is solved numerically by using the finite difference technique. The biosensor response and sensitivity are investigated by altering the model parameters influencing the enzyme kinetics as well as the mass transport by diffusion. The biosensor action was analyzed with a special emphasis to the effect of the chemical amplification. The simulation results qualitatively explain and confirm the experimentally observed effect of the synergistic substrates conversion on the biosensor response.

  14. Flexible powder electroluminescent device on silver nanowire electrode

    International Nuclear Information System (INIS)

    Park, K.W.; Jeong, H.S.; Park, J.H.; Deressa, G.; Jeong, Y.T.; Lim, K.T.; Park, J.H.; Lee, S.H.; Kim, J.S.

    2015-01-01

    We have demonstrated the flexible AC powder electroluminescent device based on Ag nanowire electrode. The Ag nanowire electrode showed the nanowire morphology of 20 nm in diameter and 15 μm in length, the transmittance of 87%, and the sheet resistance of 50 Ω/sq, and the higher flexibility than the conventional ITO substrate. The electroluminescence spectra of the Ag nanowire-based device in all frequency and voltage ranges were almost similar with the ITO-based device. In comparison with the ITO-based device, the luminous efficiency of the Ag nanowire-based device was almost same as 1.53 lm/W. - Highlights: • Flexibility of Ag NW substrate was higher than ITO substrate. • EL intensity of Ag NW-based EL device was almost similar with ITO-based EL device. • Charge density and turn-on voltage of Ag NW-based EL device were a little larger than ITO-based EL device

  15. Flexible powder electroluminescent device on silver nanowire electrode

    Energy Technology Data Exchange (ETDEWEB)

    Park, K.W.; Jeong, H.S.; Park, J.H.; Deressa, G.; Jeong, Y.T.; Lim, K.T. [Department of Display Science and Engineering, Pukyong National University, Busan 608-737 (Korea, Republic of); Park, J.H. [AIDEN company, Cheongju-si 361-911 (Korea, Republic of); Lee, S.H. [R& D Business Lab, Hyosung Corporation, Anyang 431-080 (Korea, Republic of); Kim, J.S., E-mail: jsukim@pknu.ac.kr [Department of Display Science and Engineering, Pukyong National University, Busan 608-737 (Korea, Republic of)

    2015-09-15

    We have demonstrated the flexible AC powder electroluminescent device based on Ag nanowire electrode. The Ag nanowire electrode showed the nanowire morphology of 20 nm in diameter and 15 μm in length, the transmittance of 87%, and the sheet resistance of 50 Ω/sq, and the higher flexibility than the conventional ITO substrate. The electroluminescence spectra of the Ag nanowire-based device in all frequency and voltage ranges were almost similar with the ITO-based device. In comparison with the ITO-based device, the luminous efficiency of the Ag nanowire-based device was almost same as 1.53 lm/W. - Highlights: • Flexibility of Ag NW substrate was higher than ITO substrate. • EL intensity of Ag NW-based EL device was almost similar with ITO-based EL device. • Charge density and turn-on voltage of Ag NW-based EL device were a little larger than ITO-based EL device.

  16. Carbon nanotube substrates and catalyzed hot stamp for polishing and patterning the substrates

    Science.gov (United States)

    Wang, Yuhuang [Evanston, IL; Hauge, Robert H [Houston, TX; Schmidt, Howard K [Houston, TX; Kim, Myung Jong [Houston, TX; Kittrell, W Carter [Houston, TX

    2009-09-08

    The present invention is generally directed to catalyzed hot stamp methods for polishing and/or patterning carbon nanotube-containing substrates. In some embodiments, the substrate, as a carbon nanotube fiber end, is brought into contact with a hot stamp (typically at 200-800.degree. C.), and is kept in contact with the hot stamp until the morphology/patterns on the hot stamp have been transferred to the substrate. In some embodiments, the hot stamp is made of material comprising one or more transition metals (Fe, Ni, Co, Pt, Ag, Au, etc.), which can catalyze the etching reaction of carbon with H.sub.2, CO.sub.2, H.sub.2O, and/or O.sub.2. Such methods can (1) polish the carbon nanotube-containing substrate with a microscopically smooth finish, and/or (2) transfer pre-defined patterns from the hot stamp to the substrate. Such polished or patterned carbon nanotube substrates can find application as carbon nanotube electrodes, field emitters, and field emitter arrays for displays and electron sources.

  17. Controlled dielectrophoretic nanowire self-assembly using atomic layer deposition and suspended microfabricated electrodes

    International Nuclear Information System (INIS)

    Baca, Alicia I; Brown, Joseph J; Bright, Victor M; Bertness, Kris A

    2012-01-01

    Effects of design and materials on the dielectrophoretic self-assembly of individual gallium nitride nanowires (GaN NWs) onto microfabricated electrodes have been experimentally investigated. The use of TiO 2 surface coating generated by atomic layer deposition (ALD) improves dielectrophoretic assembly yield of individual GaN nanowires on microfabricated structures by as much as 67%. With a titanium dioxide coating, individual nanowires were placed across suspended electrode pairs in 46% of tests (147 out of 320 total), versus 28% of tests (88 out of 320 total tests) that used uncoated GaN NWs. An additional result from these tests was that suspending the electrodes 2.75 μm above the substrate corresponded with up to 15.8% improvement in overall assembly yield over that of electrodes fabricated directly on the substrate. (paper)

  18. Fabrication of a Textured Non-Magnetic Ni-12at.%V Alloy Substrate for Coated Conductors

    DEFF Research Database (Denmark)

    Gao, M. M.; Grivel, Jean-Claude; Suo, H. L.

    2011-01-01

    Ni-12at.%V alloy is a promising candidate for non-magnetic cube textured metallic substrates used for high temperature coated conductors. In this work, a textured Ni-12at.%V substrate has been fabricated by powder metallurgy route. After cold rolling and recrystallization annealing, a cube texture...

  19. Application of N-doped graphene modified carbon ionic liquid electrode for direct electrochemistry of hemoglobin.

    Science.gov (United States)

    Sun, Wei; Dong, Lifeng; Deng, Ying; Yu, Jianhua; Wang, Wencheng; Zhu, Qianqian

    2014-06-01

    Nitrogen-doped graphene (NG) was synthesized and used for the investigation on direct electrochemistry of hemoglobin (Hb) with a carbon ionic liquid electrode as the substrate electrode. Due to specific characteristics of NG such as excellent electrocatalytic property and large surface area, direct electron transfer of Hb was realized with enhanced electrochemical responses appearing. Electrochemical behaviors of Hb on the NG modified electrode were carefully investigated with the electrochemical parameters calculated. The Hb modified electrode exhibited excellent electrocatalytic reduction activity toward different substrates, such as trichloroacetic acid and H2O2, with wider dynamic range and lower detection limit. These findings show that NG can be used for the preparation of chemically modified electrodes with improved performance and has potential applications in electrochemical sensing. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Effects O2 plasma surface treatment on the electrical properties of the ITO substrate

    International Nuclear Information System (INIS)

    Hong, Jin-Woong; Oh, Dong-Hoon; Shim, Sang-Min; Lee, Young-Sang; Kang, Yong-Gil; Shin, Jong-Yeol

    2012-01-01

    The indium-tin-oxide (ITO) substrate is used as a transparent electrode in organic light-emitting diodes (OLEDs) and organic photovoltaic cells. The effect of an O 2 plasma surface treatment on the electrical properties of the ITO substrate was examined. The four-point probe method, an atomic force microscope (AFM), a LCR meter, a Cole-Cole plot, and a conductive mechanism analysis were used to assess the properties of the treated ITO substrates. The four-point probe method and the AFM study revealed a lower ITO surface resistance of 17.6 Ω/sq and an average roughness of 2 nm, respectively, for a substrate treated by a plasma at 250 W for 40 s. The lower surface resistance of the ITO substrate treated at 250 W for 40 s was confirmed by using a LCR meter. An amorphous fluoropolymer (AF) was deposited on an ITO substrate treated under the optimal conditions and on a non-plasma treated ITO substrate as well. The potential barriers for charge injection in these devices were 0.25 eV and 0.15 eV, respectively, indicating a 0.1-eV decrease due to the plasma treatment.

  1. Type D personality, self-efficacy, and medication adherence in patients with heart failure-A mediation analysis.

    Science.gov (United States)

    Wu, Jia-Rong; Song, Eun Kyeung; Moser, Debra K

    2015-01-01

    Type D personality is associated with medication non-adherence. Both Type D personality and non-adherence are predictors of poor outcomes. Self-efficacy, which is modifiable, is also associated with medication adherence. To determine the relationships among Type D personality, self-efficacy, and medication adherence in 84 heart failure patients. Self-efficacy, Type D personality, medication adherence, demographic and clinical data were collected. Hierarchical linear regression was used. Type D patients were more likely to have lower self-efficacy (p = .023) and medication non-adherence (p = .027) than non-Type D patients. Low self-efficacy was associated with medication non-adherence (p mediation. Self-efficacy mediates the relationship between Type D personality and medication adherence. Developing and applying interventions to enhance self-efficacy may help to sever the link between Type D personality and poor outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Medication adherence monitoring: implications for patients and providers.

    Science.gov (United States)

    Gheorghiu, Bobby; Nayani, Seema

    2018-05-01

    Non-adherence to medication is a key worldwide issue and can lead to adverse patient outcomes and increased health system costs. Would a process facilitating notification of non-adherence infringe upon the autonomy of individuals or breach expectations of privacy? In contrast, patients who are not taking their medication could unknowingly be putting themselves at risk and all the while prescribers are unaware and without the opportunity to intervene. With the advent of electronic methods of medication adherence monitoring, this ethical dilemma now involves a new layer of complexity. We present two scenarios encountered in clinical practice that reflect issues occurring regularly in the Canadian healthcare system.

  3. Adherence performances of pressure sensitive adhesives on a model viscoelastic synthetic film: a tool for the understanding of adhesion on the human skin.

    Science.gov (United States)

    Renvoise, Julien; Burlot, Delphine; Marin, Gérard; Derail, Christophe

    2009-02-23

    This work deals with the rheological behavior and adherence properties of pressure sensitive adhesive formulations dedicated to medical applications. We have developed a specific viscoelastic substrate which mimics adhesion on human skin to measure the adherence properties of PSAs when they are stuck on the human skin. By comparing peeling results of PSAs, dedicated to medical applications, stuck on human skin and on this viscoelastic substrate we show that this substrate, based on a blend of natural proteins, presents a better representation of the interactions occurring at the skin/adhesive interface than conventional substrates used for peel test (i.e. glass and steel).

  4. Carbon nanotubes as electrode substrate material for PEM fuel cells; Kohlenstoff-Nanoroehrchen als Elektrodenmaterial fuer PEM-Brennstoffzellen

    Energy Technology Data Exchange (ETDEWEB)

    Soehn, Matthias

    2010-06-21

    This thesis reports an enhanced method to deposit nanoscaled noble metal catalysts (Pt/Ru) uniformly on carbon nanotubes based on wet chemical reduction of anorganic precursors via ethylene glycol. This well-known method is widely used to deposit noble metal catalyst particles on carbon black. Unfortunately, carbon nanotubes tend to agglomerate and therefore form bundles which cannot be penetrated by the precursor. Thus, effectiveness of the substrate is reduced. The new method prevents this by suspending the CNTs in butyl acetate by means of ultrasonic dispersion leading to a homogenous distribution. Because the butyl acetate is almost unpolar, it is nearly immiscible with the water-based ethylene glycol mixture. This problem has been solved by adding liquid Nafion {sup registered} which acts as an emulsifying agent. Thus an emulsion is created by ultrasonic treatment. This results in 30 {mu}m-sized droplets of butyl acetate with a layer of CNTs and Nafion {sup registered}. The large interface to the ethylene glycol phase yields a large surface for homogenous catalyst deposition. The prepared samples showed a narrow size distribution ({+-}0.5 nm) of small noble metal particles with loading up to 50% by weight and an average particle size of 3 nm. They are investigated using XRD, SEM, TEM, TGA-MS and CV. The added Nafion {sup registered} improves catalyst utilisation by establishing a proton conductive path to the catalyst particles. Furthermore, different manufacturing techniques for the CNT electrodes are evaluated. Thin layer Membrane-Electrode-Assemblies (MEAs) are prepared by the airbrush technique. Electrode thickness, composition and structure as well as membrane thickness is varied and the MEAs are tested in a single-cell hydrogen-oxygen-fed PEM fuel cell. The cells are characterised by cyclic IV curves which are recorded over an extended period of time, showing power densities up to 770mWcm-2 at a platinum loading of 0.3mgcm-2. Additionally, the MEAs are

  5. Vertical electric field stimulated neural cell functionality on porous amorphous carbon electrodes.

    Science.gov (United States)

    Jain, Shilpee; Sharma, Ashutosh; Basu, Bikramjit

    2013-12-01

    We demonstrate the efficacy of amorphous macroporous carbon substrates as electrodes to support neuronal cell proliferation and differentiation in electric field mediated culture conditions. The electric field was applied perpendicular to carbon substrate electrode, while growing mouse neuroblastoma (N2a) cells in vitro. The placement of the second electrode outside of the cell culture medium allows the investigation of cell response to electric field without the concurrent complexities of submerged electrodes such as potentially toxic electrode reactions, electro-kinetic flows and charge transfer (electrical current) in the cell medium. The macroporous carbon electrodes are uniquely characterized by a higher specific charge storage capacity (0.2 mC/cm(2)) and low impedance (3.3 kΩ at 1 kHz). The optimal window of electric field stimulation for better cell viability and neurite outgrowth is established. When a uniform or a gradient electric field was applied perpendicular to the amorphous carbon substrate, it was found that the N2a cell viability and neurite length were higher at low electric field strengths (≤ 2.5 V/cm) compared to that measured without an applied field (0 V/cm). While the cell viability was assessed by two complementary biochemical assays (MTT and LDH), the differentiation was studied by indirect immunostaining. Overall, the results of the present study unambiguously establish the uniform/gradient vertical electric field based culture protocol to either enhance or to restrict neurite outgrowth respectively at lower or higher field strengths, when neuroblastoma cells are cultured on porous glassy carbon electrodes having a desired combination of electrochemical properties. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Carbon coated stainless steel as counter electrode for dye sensitized solar cells

    Science.gov (United States)

    Prakash, Shejale Kiran; Sharma, Rakesh K.; Roy, Mahesh S.; Kumar, Mahesh

    2014-10-01

    A new type of counter electrode for dye sensitized solar cells has been fabricated using a stainless steel sheet as substrate and graphite, graphene and multiwall carbon nanotubes as the catalytic material which applied by screen printing technique. The sheet resistances of the substrates and there influence on the dye sensitized solar cells has been studied. The fabricated counter electrodes i.e. SS-graphite, SS-graphene SS-MWCNT and SS-platinum were tested for their photovoltaic response in the form of dye sensitized solar cells.

  7. Influence of irrigation regimens on the adherence of Enterococcus faecalis to root canal dentin.

    Science.gov (United States)

    Kishen, Anil; Sum, Chee-Peng; Mathew, Shibi; Lim, Chwee-Teck

    2008-07-01

    Enterococcus faecalis is frequently associated with post-treatment endodontic infections. Because adherence of bacteria to a substrate is the earliest stage in biofilm formation, eliciting the factors that links adherence of this bacterium to dentin would help in understanding its association with treatment-failed root canals. This investigation aimed to study the effects of endodontic irrigants on the adherence of E. faecalis to dentin. The bacteria adherence assay was conducted by using fluorescence microscopy, and the adhesion force was measured by using atomic force microscopy. There were significant increases in adherence and adhesion force after irrigation of dentin with ethylenediaminetetraacetic acid (EDTA), whereas sodium hypochlorite (NaOCl) reduced it. With the use of chlorhexidine (CHX), the force of adhesion increased, but the adherence assay showed a reduction in the number of adhering bacteria. The irrigation regimen of EDTA, NaOCl, and CHX resulted in the least number of adhering E. faecalis cells. This study highlighted that chemicals that alter the physicochemical properties of dentin will influence the nature of adherence, adhesion force, and subsequent biofilm formation of E. faecalis to dentin.

  8. Electroencephalogram measurement using polymer-based dry microneedle electrode

    Science.gov (United States)

    Arai, Miyako; Nishinaka, Yuya; Miki, Norihisa

    2015-06-01

    In this paper, we report a successful electroencephalogram (EEG) measurement using polymer-based dry microneedle electrodes. The electrodes consist of needle-shaped substrates of SU-8, a silver film, and a nanoporous parylene protective film. Differently from conventional wet electrodes, microneedle electrodes do not require skin preparation and a conductive gel. SU-8 is superior as a structural material to poly(dimethylsiloxane) (PDMS; Dow Corning Toray Sylgard 184) in terms of hardness, which was used in our previous work, and facilitates the penetration of needles through the stratum corneum. SU-8 microneedles can be successfully inserted into the skin without breaking and could maintain a sufficiently low skin-electrode contact impedance for EEG measurement. The electrodes successfully measured EEG from the frontal pole, and the quality of acquired signals was verified to be as high as those obtained using commercially available wet electrodes without any skin preparation or a conductive gel. The electrodes are readily applicable to record brain activities for a long period with little stress involved in skin preparation to the users.

  9. Micropatterning of a nanoporous alumina membrane with poly(ethylene glycol) hydrogel to create cellular micropatterns on nanotopographic substrates.

    Science.gov (United States)

    Lee, Hyun Jong; Kim, Dae Nyun; Park, Saemi; Lee, Yeol; Koh, Won-Gun

    2011-03-01

    In this paper, we describe a simple method for fabricating micropatterned nanoporous substrates that are capable of controlling the spatial positioning of mammalian cells. Micropatterned substrates were prepared by fabricating poly(ethylene glycol) (PEG) hydrogel microstructures on alumina membranes with 200 nm nanopores using photolithography. Because hydrogel precursor solution could infiltrate and become crosslinked within the nanopores, the resultant hydrogel micropatterns were firmly anchored on the substrate without the use of adhesion-promoting monolayers, thereby allow tailoring of the surface properties of unpatterned nanoporous areas. For mammalian cell patterning, arrays of microwells of different dimensions were fabricated. These microwells were composed of hydrophilic PEG hydrogel walls surrounding nanoporous bottoms that were modified with cell-adhesive Arg-Gly-Asp (RGD) peptides. Because the PEG hydrogel was non-adhesive towards proteins and cells, cells adhered selectively and remained viable within the RGD-modified nanoporous regions, thereby creating cellular micropatterns. Although the morphology of cell clusters and the number of cells inside one microwell were dependent on the lateral dimension of the microwells, adhered cells that were in direct contact with nanopores were able to penetrate into the nanopores by small extensions (filopodia) for all the different sizes of microwells evaluated. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Variation in guideline adherence in non-Hodgkin’s lymphoma care: impact of patient and hospital characteristics

    International Nuclear Information System (INIS)

    Stienen, Jozette J.C.; Hermens, Rosella P.M.G.; Wennekes, Lianne; Schans, Saskia A.M. van de; Maazen, Richard W.M. van der; Dekker, Helena M.; Liefers, Janine; Krieken, Johan H.J.M. van; Blijlevens, Nicole M.A.; Ottevanger, Petronella B.

    2015-01-01

    The objective of this observational study was to assess the influence of patient, tumor, professional and hospital related characteristics on hospital variation concerning guideline adherence in non-Hodgkin’s lymphoma (NHL) care. Validated, guideline-based quality indicators (QIs) were used as a tool to assess guideline adherence for NHL care. Multilevel logistic regression analyses were used to calculate variation between hospitals and to identify characteristics explaining this variation. Data for the QIs regarding diagnostics, therapy, follow-up and organization of care, together with patient, tumor and professional related characteristics were retrospectively collected from medical records; hospital characteristics were derived from questionnaires and publically available data. Data of 423 patients diagnosed with NHL between October 2010 and December 2011 were analyzed. Guideline adherence, as measured with the QIs, varied considerably between the 19 hospitals: >20 % variation was identified in all 20 QIs and high variation between the hospitals (>50 %) was seen in 12 QIs, most frequently in the treatment and follow-up domain. Hospital variation in NHL care was associated more than once with the characteristics age, extranodal involvement, multidisciplinary consultation, tumor type, tumor aggressiveness, LDH level, therapy used, hospital region and availability of a PET-scanner. Fifteen characteristics identified at the patient level and at the hospital level could partly explain hospital variation in guideline adherence for NHL care. Particularly age was an important determinant: elderly were less likely to receive care as measured in the QIs. The identification of determinants can be used to improve the quality of NHL care, for example, for standardizing multidisciplinary consultations in daily practice

  11. Correlation between the use of 'over-the-counter' medicines and adherence in elderly patients on multiple medications

    DEFF Research Database (Denmark)

    Olesen, Charlotte; Harbig, Philipp; Barat, Ishay

    2014-01-01

    (herbal medicines, dietary supplements, or non-prescribed drugs) was elicited during home visit interviews. Prescription drug adherence was determined by pill counts. A patient was categorised as non-adherent if the mean adherence rate for all drugs consumed was ... to be adherent than were non-users (odds ratio 0.41; 95 % confidence interval 0.18–0.91). Sensitivity analyses where adherence was defined different show no relationship between adherence and use of OTC medicine. Furthermore, separate analyses of herbal medicines, dietary supplements, or non-prescribed drugs did...... not correlate with adherence to prescriptions. Conclusion Amongst elderly patients on multiple medications a positive relationship was found between the overall use of OTC medicines and adherence to prescription drugs, in contrast to none when adherence were defined different or herbal medicines, dietary...

  12. Insulated electrocardiographic electrodes. [without paste electrolyte

    Science.gov (United States)

    David, R. M.; Portnoy, W. A. (Inventor)

    1975-01-01

    An integrated system is disclosed including an insulated electrode and an impedance transformer which can be assembled in a small plastic housing and used for the acquisition of electrocardiographic data. The electrode may be employed without a paste electrolyte and may be attached to the body for extended usage without producing skin reaction. The electrode comprises a thin layer of suitable nontoxic dielectric material preferably deposited by radio frequency sputtering onto a conductive substrate. The impedance transformer preferably comprises an operational amplifier having an FET input stage connected in the unity gain configuration which provides a very low lower cut-off frequency, a high input impedance with a very small input bias current, a low output impedance, and a high signal-to-noise ratio.

  13. Direct transparent electrode patterning on layered GaN substrate by screen printing of indium tin oxide nanoparticle ink for Eu-doped GaN red light-emitting diode

    Science.gov (United States)

    Kashiwagi, Y.; Koizumi, A.; Takemura, Y.; Furuta, S.; Yamamoto, M.; Saitoh, M.; Takahashi, M.; Ohno, T.; Fujiwara, Y.; Murahashi, K.; Ohtsuka, K.; Nakamoto, M.

    2014-12-01

    Transparent electrodes were formed on Eu-doped GaN-based red-light-emitting diode (GaN:Eu LED) substrates by the screen printing of indium tin oxide nanoparticle (ITO np) inks as a wet process. The ITO nps with a mean diameter of 25 nm were synthesized by the controlled thermolysis of a mixture of indium complexes and tin complexes. After the direct screen printing of ITO np inks on GaN:Eu LED substrates and sintering at 850 °C for 10 min under atmospheric conditions, the resistivity of the ITO film was 5.2 mΩ cm. The fabricated LED up to 3 mm square surface emitted red light when the on-voltage was exceeded.

  14. All conducting polymer electrodes for asymmetric solid-state supercapacitors

    KAUST Repository

    Kurra, Narendra

    2015-02-16

    In this study, we report the fabrication of solid-state asymmetric supercapacitors (ASCs) based on conducting polymer electrodes on a plastic substrate. Nanostructured conducting polymers of poly(3,4-ethylenedioxythiophene), PEDOT, and polyaniline (PANI) are deposited electrochemically over Au-coated polyethylene naphthalate (PEN) plastic substrates. Due to the electron donating nature of the oxygen groups in the PEDOT, reduction potentials are higher, allowing it to be used as a negative electrode material. In addition, the high stability of PEDOT in its oxidised state makes it capable to exhibit electrochemical activity in a wide potential window. This can qualify PEDOT to be used as a negative electrode in fabricating asymmetric solid state supercapacitors with PANI as a positive electrode while employing polyvinyl alcohol (PVA)/H2SO4 gel electrolyte. The ASCs exhibit a maximum power density of 2.8 W cm−3 at an energy density of 9 mW h cm−3, which is superior to the carbonaceous and metal oxide based ASC solid state devices. Furthermore, the tandem configuration of asymmetric supercapacitors is shown to be capable of powering a red light emitting diode for about 1 minute after charging for 10 seconds.

  15. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  16. Electrochromic Characteristics of Nitrogen-Doped Graphene/TiO2 Nanocomposite Electrodes

    International Nuclear Information System (INIS)

    Yang, Chien-Hsin; Chen, Shih-Ming; Wang, Tzong-Liu; Shieh, Yeong-Tarng

    2014-01-01

    Nitrogen-doped graphene (NDG)/titanium dioxide (TiO 2 ) nanoparticles were coated on indium-tin oxide (ITO) glass substrates to fabricate NDG-TiO 2 nanocomposite electrodes. 3-methylthiophene (3MT) was electrochemically deposited on the NDG-TiO 2 films to form poly(3-methylthiophene) (P3MT/NDG/TiO 2 ) composite electrochromic electrodes. The introduction of NDG and TiO 2 mesoporous films significantly increased the initial maximum optical contrast (ΔT%) to 70% as compared 41% of pure ITO electrodes, whereas the P3MT/NDG/TiO 2 composite electrodes enhanced the adhesion of P3MT polymers to the NDG/TiO 2 /ITO substrate, thereby increasing the long-term stability of the corresponding electrochromic devices. Experimental results reveal that P3MT/NDG/TiO 2 composite electrodes retained up to 90% of ΔT%, relative to 70% remaining ΔT% of pure ITO electrodes. This illustrates the enhanced long-term stability achieved through the introduction of a NDG-TiO 2 nanocomposite films in electrochromic devices. These devices demonstrated excellent response time characteristics and ΔT% value of 6 s and ca. of 70%, respectively. This work has shown that conductive polymer/NDG/TiO 2 composite electrodes are well suited to electrochromic devices for the promotion of performance and stability

  17. Solution of non-steady-state substrate concentration in the action of biosensor response at mixed enzyme kinetics

    Science.gov (United States)

    Senthamarai, R.; Jana Ranjani, R.

    2018-04-01

    In this paper, a mathematical model of an amperometric biosensor at mixed enzyme kinetics and diffusion limitation in the case of substrate inhibition has been developed. The model is based on time dependent reaction diffusion equation containing a non -linear term related to non -Michaelis - Menten kinetics of the enzymatic reaction. Solution for the concentration of the substrate has been derived for all values of parameters using the homotopy perturbation method. All the approximate analytic expressions of substrate concentration are compared with simulation results using Scilab/Matlab program. Finally, we have given a satisfactory agreement between them.

  18. Electrospinning onto Insulating Substrates by Controlling Surface Wettability and Humidity

    Science.gov (United States)

    Choi, WooSeok; Kim, Geon Hwee; Shin, Jung Hwal; Lim, Geunbae; An, Taechang

    2017-11-01

    We report a simple method for electrospinning polymers onto flexible, insulating substrates by controlling the wettability of the substrate surface. Water molecules were adsorbed onto the surface of a hydrophilic polymer substrate by increasing the local humidity around the substrate. The adsorbed water was used as the ground electrode for electrospinning. The electrospun fibers were deposited only onto hydrophilic areas of the substrate, allowing for patterning through wettability control. Direct writing of polymer fiber was also possible through near-field electrospinning onto a hydrophilic surface.

  19. MAPLE deposition of 3D micropatterned polymeric substrates for cell culture

    Energy Technology Data Exchange (ETDEWEB)

    Paun, Irina Alexandra, E-mail: irina.paun@physics.pub.ro [National Institute for Laser, Plasma and Radiation Physics, RO-077125, Magurele, Bucharest (Romania); Faculty of Applied Sciences, University Politehnica of Bucharest, RO-060042, Bucharest (Romania); Mihailescu, Mona [Faculty of Applied Sciences, University Politehnica of Bucharest, RO-060042, Bucharest (Romania); Calenic, Bogdan [Department of Biochemistry, Faculty of Dentistry, UMF Carol Davila, Bucharest (Romania); Luculescu, Catalin Romeo [National Institute for Laser, Plasma and Radiation Physics, RO-077125, Magurele, Bucharest (Romania); Greabu, Maria [Department of Biochemistry, Faculty of Dentistry, UMF Carol Davila, Bucharest (Romania); Dinescu, Maria, E-mail: dinescum@nipne.ro [National Institute for Laser, Plasma and Radiation Physics, RO-077125, Magurele, Bucharest (Romania)

    2013-08-01

    3D micropatterned poly(lactide-co-glycolide)/polyurethane (PLGA/PU) substrates were produced by MAPLE deposition through masks and used for regulating the behavior of oral keratinocyte stem cells in response to topography. Flat PLGA/PU substrates were produced for comparison. 3D imaging of the PLGA/PU substrates and of the cultured cells was performed by Digital Holographic Microscopy. The micropatterns were in the shape of squares of 50 × 50 and 80 × 80 μm{sup 2} areas, ∼1.8 μm in height and separated by 20 μm wide channels. It was found that substrate topography guided the adhesion of the cultured cells: on the smooth substrates the cells adhered randomly and showed no preferred orientation; in contrast, on the micropatterned substrates the cells adhered preferentially onto the squares and not in the separating channels. Furthermore, key properties of the cells (size, viability, proliferation rate and stem cell marker expression) did not show any dependence on substrate topography. The size of the cultured cells, their viability, the proportions of actively/slow proliferating cells, as well as the stem cell markers expressions, were similar for both flat and micropatterned substrates. Finally, it was found that the cells cultured on the PLGA/PU substrates deposited by MAPLE exhibited similar properties as the controls (i.e. cells cultured on glass slides), indicating the capability of the former to preserve the properties of the keratinocyte stem cells.

  20. Electrochemically Driven Fermentation of Organic Substrates with Undefined Mixed Microbial Cultures.

    Science.gov (United States)

    Villano, Marianna; Paiano, Paola; Palma, Enza; Miccheli, Alfredo; Majone, Mauro

    2017-08-10

    Growing scientific interest in mixed microbial culture-based anaerobic biotechnologies for the production of value-added chemicals and fuels from organic waste residues requires a parallel focus on the development and implementation of strategies to control the distribution of products. This study examined the feasibility of an electrofermentation approach, based on the introduction of a polarized (-700 mV vs. the standard hydrogen electrode) graphite electrode in the fermentation medium, to steer the product distribution during the conversion of organic substrates (glucose, ethanol, and acetate supplied as single compounds or in mixtures) by undefined mixed microbial cultures. In batch experiments, the polarized electrode triggered a nearly 20-fold increase (relative to open circuit controls) in the yield of isobutyrate production (0.43±0.01 vs. 0.02±0.02 mol mol -1 glucose) during the anaerobic fermentation of the ternary mixture of substrates, without adversely affecting the rate of substrate bioconversion. The observed change in the fermentative metabolism was most likely triggered by the (potentiostatic) regulation of the oxidation-reduction potential of the reaction medium rather than by the electrode serving as an electron donor. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Tailored ion energy distributions on plasma electrodes

    International Nuclear Information System (INIS)

    Economou, Demetre J.

    2013-01-01

    As microelectronic device features continue to shrink approaching atomic dimensions, control of the ion energy distribution on the substrate during plasma etching and deposition becomes increasingly critical. The ion energy should be high enough to drive ion-assisted etching, but not too high to cause substrate damage or loss of selectivity. In many cases, a nearly monoenergetic ion energy distribution (IED) is desired to achieve highly selective etching. In this work, the author briefly reviews: (1) the fundamentals of development of the ion energy distribution in the sheath and (2) methods to control the IED on plasma electrodes. Such methods include the application of “tailored” voltage waveforms on an electrode in continuous wave plasmas, or the application of synchronous bias on a “boundary electrode” during a specified time window in the afterglow of pulsed plasmas

  2. Organic ferroelectric memory devices with inkjet-printed polymer electrodes on flexible substrates

    KAUST Repository

    Bhansali, Unnat Sampatraj

    2013-05-01

    Drop-on-demand piezoelectric inkjet-printing technique has been used to fabricate a functional cross-bar array of all-organic ferroelectric memory devices. The polymer-ferroelectric-polymer device consists of a ferroelectric copolymer P(VDF-TrFE) film sandwiched between inkjet-patterned, continuous, orthogonal lines of PEDOT:PSS polymer as the bottom and top electrodes. These devices exhibit well-saturated hysteresis curves with a maximum remnant polarization (Pr) = 6.7 μC/cm2, coercive field (E c) = 55 MV/m and a peak capacitance density of 45 nF/cm2. Our polarization fatigue measurements show that these devices retain ∼100% and 45% of their initial Pr values after 103 and 10 5 stress cycles, respectively. The overall performance and polarization retention characteristics of these ferroelectric capacitors with inkjet-printed polymer electrodes are comparable to metal and spin-cast polymer electrodes suggesting their potential use in large-area flexible electronics. © 2013 Elsevier Ltd. All rights reserved.

  3. Alkali metal ion battery with bimetallic electrode

    Science.gov (United States)

    Boysen, Dane A; Bradwell, David J; Jiang, Kai; Kim, Hojong; Ortiz, Luis A; Sadoway, Donald R; Tomaszowska, Alina A; Wei, Weifeng; Wang, Kangli

    2015-04-07

    Electrochemical cells having molten electrodes having an alkali metal provide receipt and delivery of power by transporting atoms of the alkali metal between electrode environments of disparate chemical potentials through an electrochemical pathway comprising a salt of the alkali metal. The chemical potential of the alkali metal is decreased when combined with one or more non-alkali metals, thus producing a voltage between an electrode comprising the molten the alkali metal and the electrode comprising the combined alkali/non-alkali metals.

  4. Investigation of the electrochemical behaviour of thermally prepared Pt-IrO2 electrodes

    Directory of Open Access Journals (Sweden)

    Konan Honoré Kondro

    2008-04-01

    Full Text Available Different IrO2 electrodes in which the molar percentage of platinum (Pt varies from 0 %mol Pt to 100 %mol Pt were prepared on titanium (Ti substrate by thermal decomposition techniques. The electrodes were characterized physically (SEM, XPS and electrochemically and then applied to methanol oxidation. The SEM micrographs indicated that the electrodes present different morphologies depending on the amount of platinum in the deposit and the cracks observed on the 0 %mol Pt electrode diminish in size tending to a compact and rough surface for 70 %mol Pt electrode. XPS results indicate good quality of the coating layer deposited on the titanium substrate. The voltammetric investigations in the supporting electrolyte indicate that the electrodes with low amount of platinum (less than 10 %mol Pt behave as pure IrO2. But in the case of electrodes containing more than 40 %mol Pt, the voltammograms are like that of platinum. Electrocatalytic activity towards methanol oxidation was observed with the electrodes containing high amount of platinum. Its oxidation begins at a potential of about 210 mV lower on such electrodes than the pure platinum electrode (100 %mol Pt. But for electrode containing low quantity of Pt, the surface of the coating is essentially composed of IrO2 and methanol oxidation occurs in the domain of water decomposition solely. The increase of the electrocatalytic behaviour of the electrodes containing high amount of Pt towards methanol oxidation is due to the bifunctional behaviour of the electrodes.

  5. Factors Associated with Adherence to and Treatment Duration of Erlotinib Among Patients with Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Hess, Lisa M; Louder, Anthony; Winfree, Katherine; Zhu, Yajun E; Oton, Ana B; Nair, Radhika

    2017-06-01

    In lung cancer, there is an increasing number of oral agents available for patients; however, little is known about the factors associated with adherence to and treatment duration on oral medications in non-small cell lung cancer (NSCLC). To evaluate the clinical and demographic factors associated with adherence and treatment discontinuation, respectively, to oral oncolytics among patients with NSCLC. A retrospective, claims-based analysis of the Humana Research Database supplemented with medical chart review was conducted among patients with NSCLC who started an oral oncolytic between January 1, 2008, and June 30, 2013. Patients were required to be enrolled at least 1 year before the start of oral oncolytics and have no evidence of any oral oncolytic use during this period. Logistic regression models and Cox proportional hazard models were used to identify predictors associated with medication adherence and treatment duration, respectively. Among all oral oncolytics, only the cohort starting on erlotinib had sufficient sample size (n = 1,452). A wide variety of factors were found to be associated with adherence. Low-income subsidy status, previous use of intravenous chemotherapy, and lower total baseline health care costs were significantly related to decreasing adherence (each P cost was associated with decreasing adherence to erlotinib (P costs (P Company to Comprehensive Health Insights, a Humana company, as a collaborative research project involving employees of both companies. Hess, Winfree, Zhu, and Oton are employees of Eli Lilly and Company. Louder and Nair are employees of Comprehensive Health Insights, which received funding to complete this research. Study concept and design were contributed by Hess, Zhu, Winfree, and Oton. Nair and Louder collected the data, and data interpretation was performed by all the authors. The manuscript was written primarily by Hess, along with Nair, and revised by Hess, Nair, Louder, and Winfree, with assistance from Zhu and

  6. Impact of non-adherent Ibuprofen foam dressing in the lives of patients with venous ulcers

    Directory of Open Access Journals (Sweden)

    GERALDO MAGELA SALOMÉ

    Full Text Available ABSTRACT Objective : to evaluate pain in patients with lower limb venous ulcer who used non-adherent Ibuprofen foam dressing (IFD. Methods : we conducted a prospective study of patients with lower limb venous ulcers treated from April 2013 to August 2014. We used the Numerical Scale and McGill Pain Questionnaire, performing the assessments at the moment of inclusion of the patient in the study and every eight days thereafter, totaling five consultations. We divided the patients into two groups: 40 in the Study Group (SG, who were treated with IFD, and 40 in the Control Group (CG, treated with primary dressing, according to tissue type and exudate. Results : at the first consultation, patients from both groups reported intense pain. On the fifth day, SG patients reported no pain and the majority of CG reported moderate pain. Regarding the McGill Pain Questionnaire, most patients of both groups reported sensations related to sensory, affective, evaluative and miscellaneous descriptors at the beginning of data collection; after the second assessment, there was slight improvement among the patients in the SG. After the third consultation, they no longer reported the mentioned descriptors. CG patients displayed all the sensations of these descriptors until the fifth visit. Conclusion : non-adherent Ibuprofen foam dressing is effective in reducing the pain of patients with venous ulcers.

  7. Interleukin-3 greatly expands non-adherent endothelial forming cells with pro-angiogenic properties

    Directory of Open Access Journals (Sweden)

    Lachlan M. Moldenhauer

    2015-05-01

    Full Text Available Circulating endothelial progenitor cells (EPCs provide revascularisation for cardiovascular disease and the expansion of these cells opens up the possibility of their use as a cell therapy. Herein we show that interleukin-3 (IL3 strongly expands a population of human non-adherent endothelial forming cells (EXnaEFCs with low immunogenicity as well as pro-angiogenic capabilities in vivo, making their therapeutic utilisation a realistic option. Non-adherent CD133+ EFCs isolated from human umbilical cord blood and cultured under different conditions were maximally expanded by day 12 in the presence of IL3 at which time a 350-fold increase in cell number was obtained. Cell surface marker phenotyping confirmed expression of the hematopoietic progenitor cell markers CD133, CD117 and CD34, vascular cell markers VEGFR2 and CD31, dim expression of CD45 and absence of myeloid markers CD14 and CD11b. Functional experiments revealed that EXnaEFCs exhibited classical properties of endothelial cells (ECs, namely binding of Ulex europaeus lectin, up-take of acetylated-low density lipoprotein and contribution to EC tube formation in vitro. These EXnaEFCs demonstrated a pro-angiogenic phenotype within two independent in vivo rodent models. Firstly, a Matrigel plug assay showed increased vascularisation in mice. Secondly, a rat model of acute myocardial infarction demonstrated reduced heart damage as determined by lower levels of serum creatinine and a modest increase in heart functionality. Taken together, these studies show IL3 as a potent growth factor for human CD133+ cell expansion with clear pro-angiogenic properties (in vitro and in vivo and thus may provide clinical utility for humans in the future.

  8. Adherence to immunosuppression in adult lung transplant recipients : Prevalence and risk factors

    NARCIS (Netherlands)

    Bosma, Otto H.; Vermeulen, Karin M.; Verschuuren, Erik A.; Erasmus, Michiel E.; van der Bij, Wim

    2011-01-01

    BACKGROUND: Adherence to medication is a favourable with regard to survival after kidney, heart and liver transplantation. Little is known about adherence to medication in lung transplant recipients. To determine the prevalence of adherence and identify risk factors of non-adherence (NA) we

  9. Factors influencing adherence to antiretroviral treatment in Nepal: a mixed-methods study.

    Science.gov (United States)

    Wasti, Sharada P; Simkhada, Padam; Randall, Julian; Freeman, Jennifer V; van Teijlingen, Edwin

    2012-01-01

    Antiretroviral therapy (ART) is a lifesaver for individual patients treated for Human Immunodeficiency Virus (HIV) and Acquired Immune Deficiency Syndrome (AIDS). Maintaining optimal adherence to antiretroviral drugs is essential for HIV infection management. This study aimed to understand the factors influencing adherence amongst ART-prescribed patients and care providers in Nepal. A cross-sectional mixed-methods study surveying 330 ART-prescribed patients and 34 in-depth interviews with three different types of stakeholders: patients, care providers, and key people at policy level. Adherence was assessed through survey self-reporting and during the interviews. A multivariate logistic regression model was used to identify factors associated with adherence, supplemented with a thematic analysis of the interview transcripts. A total of 282 (85.5%) respondents reported complete adherence, i.e. no missed doses in the four-weeks prior to interview. Major factors influencing adherence were: non-disclosure of HIV status (OR = 17.99, p = 0.014); alcohol use (OR = 12.89, p = 1 hour (OR = 2.84, p = 0.035). Similarly, lack of knowledge and negative perception towards ART medications also significantly affected non-adherence. Transport costs (for repeat prescription), followed by pills running out, not wanting others to notice, side-effects, and being busy were the most common reasons for non-adherence. The interviews also revealed religious or ritual obstacles, stigma and discrimination, ART-associated costs, transport problems, lack of support, and side-effects as contributing to non-adherence. Improving adherence requires a supportive environment; accessible treatment; clear instructions about regimens; and regimens tailored to individual patients' lifestyles. Healthcare workers should address some of the practical and cultural issues around ART medicine whilst policy-makers should develop appropriate social policy to promote adherence among ART

  10. Factors influencing adherence to antiretroviral treatment in Nepal: a mixed-methods study.

    Directory of Open Access Journals (Sweden)

    Sharada P Wasti

    Full Text Available BACKGROUND: Antiretroviral therapy (ART is a lifesaver for individual patients treated for Human Immunodeficiency Virus (HIV and Acquired Immune Deficiency Syndrome (AIDS. Maintaining optimal adherence to antiretroviral drugs is essential for HIV infection management. This study aimed to understand the factors influencing adherence amongst ART-prescribed patients and care providers in Nepal. METHODS: A cross-sectional mixed-methods study surveying 330 ART-prescribed patients and 34 in-depth interviews with three different types of stakeholders: patients, care providers, and key people at policy level. Adherence was assessed through survey self-reporting and during the interviews. A multivariate logistic regression model was used to identify factors associated with adherence, supplemented with a thematic analysis of the interview transcripts. RESULTS: A total of 282 (85.5% respondents reported complete adherence, i.e. no missed doses in the four-weeks prior to interview. Major factors influencing adherence were: non-disclosure of HIV status (OR = 17.99, p = 0.014; alcohol use (OR = 12.89, p = 1 hour (OR = 2.84, p = 0.035. Similarly, lack of knowledge and negative perception towards ART medications also significantly affected non-adherence. Transport costs (for repeat prescription, followed by pills running out, not wanting others to notice, side-effects, and being busy were the most common reasons for non-adherence. The interviews also revealed religious or ritual obstacles, stigma and discrimination, ART-associated costs, transport problems, lack of support, and side-effects as contributing to non-adherence. CONCLUSION: Improving adherence requires a supportive environment; accessible treatment; clear instructions about regimens; and regimens tailored to individual patients' lifestyles. Healthcare workers should address some of the practical and cultural issues around ART medicine whilst policy-makers should develop

  11. Factors Influencing Adherence to Antiretroviral Treatment in Nepal: A Mixed-Methods Study

    Science.gov (United States)

    Wasti, Sharada P.; Simkhada, Padam; Randall, Julian; Freeman, Jennifer V.; van Teijlingen, Edwin

    2012-01-01

    Background Antiretroviral therapy (ART) is a lifesaver for individual patients treated for Human Immunodeficiency Virus (HIV) and Acquired Immune Deficiency Syndrome (AIDS). Maintaining optimal adherence to antiretroviral drugs is essential for HIV infection management. This study aimed to understand the factors influencing adherence amongst ART-prescribed patients and care providers in Nepal. Methods A cross-sectional mixed-methods study surveying 330 ART-prescribed patients and 34 in-depth interviews with three different types of stakeholders: patients, care providers, and key people at policy level. Adherence was assessed through survey self-reporting and during the interviews. A multivariate logistic regression model was used to identify factors associated with adherence, supplemented with a thematic analysis of the interview transcripts. Results A total of 282 (85.5%) respondents reported complete adherence, i.e. no missed doses in the four-weeks prior to interview. Major factors influencing adherence were: non-disclosure of HIV status (OR = 17.99, p =  0.014); alcohol use (OR = 12.89, p = 1 hour (OR = 2.84, p = 0.035). Similarly, lack of knowledge and negative perception towards ART medications also significantly affected non-adherence. Transport costs (for repeat prescription), followed by pills running out, not wanting others to notice, side-effects, and being busy were the most common reasons for non-adherence. The interviews also revealed religious or ritual obstacles, stigma and discrimination, ART-associated costs, transport problems, lack of support, and side-effects as contributing to non-adherence. Conclusion Improving adherence requires a supportive environment; accessible treatment; clear instructions about regimens; and regimens tailored to individual patients’ lifestyles. Healthcare workers should address some of the practical and cultural issues around ART medicine whilst policy-makers should develop appropriate social

  12. Method for fabricating carbon/lithium-ion electrode for rechargeable lithium cell

    Science.gov (United States)

    Huang, Chen-Kuo (Inventor); Surampudi, Subbarao (Inventor); Attia, Alan I. (Inventor); Halpert, Gerald (Inventor)

    1995-01-01

    The method includes steps for forming a carbon electrode composed of graphitic carbon particles adhered by an ethylene propylene diene monomer binder. An effective binder composition is disclosed for achieving a carbon electrode capable of subsequent intercalation by lithium ions. The method also includes steps for reacting the carbon electrode with lithium ions to incorporate lithium ions into graphitic carbon particles of the electrode. An electrical current is repeatedly applied to the carbon electrode to initially cause a surface reaction between the lithium ions and to the carbon and subsequently cause intercalation of the lithium ions into crystalline layers of the graphitic carbon particles. With repeated application of the electrical current, intercalation is achieved to near a theoretical maximum. Two differing multi-stage intercalation processes are disclosed. In the first, a fixed current is reapplied. In the second, a high current is initially applied, followed by a single subsequent lower current stage. Resulting carbon/lithium-ion electrodes are well suited for use as an anode in a reversible, ambient temperature, lithium cell.

  13. Development of a Novel Solid-State Sensor Electrode Based on Titanium Thin Film as an Indicator Electrode in Potentiometric and Conductometric Acid-Base Titration in Aqueous Solution

    OpenAIRE

    Abu Ghalwa, Nasser

    2012-01-01

    A modified Ti/(SnO2 + Sb2O3) electrode was prepared by thermal deposition on titanium substrate and its use as indicator electrode to potentiometric and conductometric acid-base titration in aqueous solution at 298 K was developed. The E-pH curve is linear with slope of 0.0512 V/dec at 298 K. The standard potential of this electrode, E0, was determined with respect to the SCE as reference electrode. The recovery percentages for potentiometric and conductometric acid-base titration for acetic ...

  14. Polypyrrole electrodes doped with sulfanilic acid azochromotrop for electrochemical supercapacitors

    Science.gov (United States)

    Chen, S.; Zhitomirsky, I.

    2013-12-01

    In this work we demonstrate the feasibility of deposition of polypyrrole (PPy) films by electropolymerization on stainless steel substrates and fabrication of PPy powders by chemical polymerization using sulfanilic acid azochromotrop (SPADNS) as a new anionic dopant. The problem of low adhesion of PPy films to stainless steel substrates is addressed by the use of SPADNS, which exhibits chelating properties, promoting film formation. The use of fine particles, prepared by the chemical polymerization method, allows impregnation of Ni foams and fabrication of porous electrodes with high materials loading for electrochemical supercapacitors (ES). PPy films and Ni foam based PPy electrodes show capacitive behaviour in Na2SO4 electrolyte. The electron microscopy studies, impedance spectroscopy data and analysis of the SPADNS structure provide an insight into the factors, controlling capacitive behaviour. The Ni foam based electrodes offer advantages of improved capacitive behaviour at high materials loadings and good cycling stability. The area normalized and volume normalized specific capacitances are as high as 5.43 F cm-2 and 93.6 F cm-3, respectively, for materials loading of 35.4 mg cm-2. The capacitance retention of Ni foam based electrodes is 91.5% after 1000 cycles. The Ni foam based PPy electrodes are promising for application in ES.

  15. Effect of substrate nature on the electrochemical deposition of calcium-deficient hydroxyapatites

    Science.gov (United States)

    Gualdrón-Reyes, A. F.; Domínguez-Vélez, V.; Morales-Morales, J. A.; Cabanzo, R.; Meléndez, A. M.

    2017-01-01

    Calcium phosphates were obtained by reducing nitrate ions to produce hydroxide ions on TiO2/stainless steel and TiO2/titanium electrodes. TiO2 coatings on metallic substrates were prepared by sol-gel dip-coating method. The morphology of deposits was observed by FESEM. Chemical nature of calcium phosphate deposits was identified by Raman micro-spectroscopy and FESEM/EDS microanalysis. Electrochemical behavior of nitrate and nitrite reduction on stainless steel and titanium electrodes was studied by linear sweep voltammetry. In addition, voltammetric study of the calcium phosphate electrodeposition on both electrodes was performed. From these measurements was selected the potential to form a calcium phosphate. A catalytic current associated to nitrate reduction reaction was obtained for stainless steel electrode, leading to significant deposition of calcium phosphate. Ca/P ratio for both substrates was less than 1.67. The formation of calcium deficient hydroxyapatite was confirmed by Raman spectroscopy.

  16. Assessing medication adherence in inflammatory bowel diseases. A comparison between a self-administered scale and a pharmacy refill index.

    Science.gov (United States)

    de Castro, María Luisa; Sanromán, Luciano; Martín, Alicia; Figueira, Montserrat; Martínez, Noemi; Hernández, Vicent; Del Campo, Victor; Pineda, Juan R; Martínez-Cadilla, Jesús; Pereira, Santos; Rodríguez Prada, José Ignacio

    2017-08-01

    Medication non-adherence in inflammatory bowel disease (IBD) has a negative impact on disease outcome. Different tools have been proposed to assess non-adherence. We aimed to compare a self-administered scale and a pharmacy refill index as a reliable measure of medication adherence and to determine what factors are related to adherence. Consecutive non-active IBD outpatients were asked to fill in the self-reported Morisky Medication Adherence Scale (MMAS-8) and the Beliefs about Medication Questionnaire (BMQ). Pharmacy refill data were reviewed from the previous three or six months and the medication possession ratio (MPR) was calculated. Non-adherence was defined as MMAS-8 scores harm of medication were significantly associated with MPR non-adherence (p = 0.01). The accuracy of MMAS-8 to identify medication non-adherence in inactive IBD outpatients in our setting is poor due to a low specificity and a negative predictive value. Psychosocial factors such as beliefs about medication seem to be related to IBD non-adherence.

  17. Furthering patient adherence: A position paper of the international expert forum on patient adherence based on an internet forum discussion

    NARCIS (Netherlands)

    Dulmen, S. van; Sluijs, E.; Dijk, Liset van; Ridder, D.T.D. de; Heerdink, R.; Bensing, J.

    2008-01-01

    Background: As the problem of patient non-adherence persists and a solution appears hard to be found, it continues to be important to look for new ways to further the issue. We recently conducted a meta-review of adherence intervention studies which yielded a preliminary agenda for future

  18. Surface modification on 304 SS by plasma-immersed ion implantation to improve the adherence of a CVD diamond film

    Energy Technology Data Exchange (ETDEWEB)

    Nono, M.C.A.; Corat, E.J. (Instituto Nacional de Pesquisas Espaciais, Sao Jose dos Campos, SP (Brazil)); Ueda, M.; Stellati, C.; Barroso, J.J.; Conrad, J.R.; Shamim, M.; Fetherston, P.; Sridharan, K.

    1999-02-01

    The weak adherence of chemical vapor deposited (CVD) diamond films on steel substrates is an important factor that limits the technological applications of these materials. We are interested in enhancing the film-to-substrate adherence by using substrate surfaces with a previous modification by plasma-immersed ion implantation (PIII). In this work we present and discuss the preliminary results on phase formation, microstructure and adherence evaluations. CVD diamond films were deposited on 304 SS, the surface of which was modified by implanted carbon ions. The samples were first submitted to implantation with 30 keV carbon ions at different doses. Later, these surfaces were examined by Auger spectroscopy (SAM), scanning electron microscopy (SEM) and X-ray diffraction. We observed a metastable carbide phase formed from carbon and iron, which is considered to be a good polycrystalline material for the nucleation of CVD diamond crystals. The CVD diamond nucleation and film growth were observed by SEM and Raman spectroscopy. These results are discussed with the emphasis on the carbon diffusion barrier on the substrate surfaces. The preliminary results of diamond growth were encouraging. (orig.) 7 refs.

  19. Electrochemical characterization of calcium cobaltite based porous electrodes

    International Nuclear Information System (INIS)

    Fulgencio, E.B.G.A.; Vasconcelos, K.; Silva, R.M.; Melo, P.; Caetano, A.A.; Campos, L.F.A.; Dutra, R.P.S.; Macedo, D.A.

    2016-01-01

    Materials based on alkali metal oxides and alkaline earth metal have shown high technological interest in recent years. Among these materials, calcium and cobalt oxide composition Ca_3Co_4O_9 (C349) has emerged as thermoelectric material and, more recently, as cathode for solid oxide fuel cell (SOFC). In this study, C349 powder was obtained by solid state reaction of a mixture containing cobalt oxide and calcium carbonate from shellfish shells (CaCO_3 ∼ 98%), previously calcined at 550° C. Symmetrical cells (cathode / substrate / cathode) were prepared by screen printing of C349 electrodes in gadolinium-doped ceria substrates. The characterization by electrochemical impedance spectroscopy revealed that the C349 obtained in this work has an area specific resistance compatible with electrodes obtained by chemical routes (from literature). (author)

  20. Optimization and fabrication of porous carbon electrodes for Fe/Cr redox flow cells

    Science.gov (United States)

    Jalan, V.; Morriseau, B.; Swette, L.

    1982-01-01

    Negative electrode development for the NASA chromous/ferric Redox battery is reported. The effects of substrate material, gold/lead catalyst composition and loading, and catalyzation procedures on the performance of the chromium electrode were investigated. Three alternative catalyst systems were also examined, and 1/3 square foot size electrodes were fabricated and delivered to NASA at the conclusion of the program.

  1. Frequency and predictors of non-adherence to lifestyle modifications and medications after coronary artery bypass grafting: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Muhammad Armughan Ali

    2017-07-01

    Conclusion: Non-adherence to lifestyle modifications and medication is an emerging problem worldwide. It is essential for medical health professionals to discuss these predictors and address them individually. Our findings highlight the need for a healthy physician and patient relationship.

  2. Factors affecting adherence to antiretroviral therapy among pregnant women in the Eastern Cape, South Africa.

    Science.gov (United States)

    Adeniyi, Oladele Vincent; Ajayi, Anthony Idowu; Ter Goon, Daniel; Owolabi, Eyitayo Omolara; Eboh, Alfred; Lambert, John

    2018-04-13

    Context-specific factors influence adherence to antiretroviral therapy (ART) among pregnant women living with HIV. Gaps exist in the understanding of the reasons for the variable outcomes of the prevention of mother-to-child transmission (PMTCT) programme at the health facility level in South Africa. This study examined adherence levels and reasons for non-adherence during pregnancy in a cohort of parturient women enrolled in the PMTCT programme in the Eastern Cape, South Africa. This was a mixed-methods study involving 1709 parturient women in the Eastern Cape, South Africa. We conducted a multi-centre retrospective analysis of the mother-infant pair in the PMTCT electronic database in 2016. Semi-structured interviews of purposively selected parturient women with self-reported poor adherence (n = 177) were conducted to gain understanding of the main barriers to adherence. Binary logistic regression was used to determine the independent predictors of ART non-adherence. A high proportion (69.0%) of women reported perfect adherence. In the logistic regression analysis, after adjusting for confounding factors, marital status, cigarette smoking, alcohol use and non-disclosure to a family member were the independent predictors of non-adherence. Analysis of the qualitative data revealed that drug-related side-effects, being away from home, forgetfulness, non-disclosure, stigma and work-related demand were among the main reasons for non-adherence to ART. Non-adherence to the antiretroviral therapy among pregnant women in this setting is associated with lifestyle behaviours, HIV-related stigma and ART side-effects. In order to eliminate mother-to-child transmission of HIV, clinicians need to screen for these factors at every antenatal clinic visit.

  3. The prevalence and factors associated for anti-tuberculosis treatment non-adherence among pulmonary tuberculosis patients in public health care facilities in South Ethiopia: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Tadele Teshome Woimo

    2017-03-01

    Full Text Available Abstract Background Evidence exists pointing out how non-adherence to treatment remains a major hurdle to efficient tuberculosis control in developing countries. Many tuberculosis (Tb patients do not complete their six-month course of anti-tuberculosis medications and are not aware of the importance of sputum re-examinations, thereby putting themselves at risk of developing multidrug-resistant and extensively drug-resistant forms of tuberculosis and relapse. However, there is a dearth of publications about non-adherence towards anti-Tb medication in these settings. We assessed the prevalence of and associated factors for anti-Tb treatment non-adherence in public health care facilities of South Ethiopia. Methods This was a cross-sectional survey using both quantitative and qualitative methods. The quantitative study was conducted among 261 Tb patients from 17 health centers and one general hospital. The qualitative aspect included an in-depth interview of 14 key informants. For quantitative data, the analysis of descriptive statistics, bivariate and multiple logistic regression was carried out, while thematic framework analysis was applied for the qualitative data. Results The prevalence of non-adherence towards anti-Tb treatment was 24.5%. Multiple logistic regression analysis demonstrated that poor knowledge towards tuberculosis and its treatment (AOR = 4.6, 95%CI: 1.4-15.6, cost of medication other than Tb (AOR = 4.7, 95%CI: 1.7-13.4, having of health information at every visit (AOR = 3, 95% CI: 1.1-8.4 and distance of DOTS center from individual home (AOR = 5.7, 95%CI: 1.9-16.8 showed statistically significant association with non-adherence towards anti- tuberculosis treatment. Qualitative study also revealed that distance, lack of awareness about importance of treatment completion and cost of transportation were the major barriers for adherence. Conclusions A quarter of Tb patients interrupted their treatment due to knowledge

  4. Episodic medication adherence in adolescents and young adults with perinatally acquired HIV: a within-participants approach.

    Science.gov (United States)

    Hawkins, Amy; Evangeli, Michael; Sturgeon, Kate; Le Prevost, Marthe; Judd, Ali

    2016-01-01

    Due to the success of antiretroviral (ART) medications, young people living with perinatally acquired HIV (PHIV+) are now surviving into adolescence and young adulthood. Understanding factors influencing ART non-adherence in this group is important in developing effective adherence interventions. Most studies of ART adherence in HIV-positive populations assess differences in adherence levels and adherence predictors between participants, over a period of time (global adherence). Many individuals living with HIV, however, including PHIV+ young people, take medication inconsistently. To investigate this pattern of adherence, a within-participants design, focussing on specific episodes of adherence and non-adherence, is suitable (episodic adherence). A within-participants design was used with 29 PHIV+ young people (17 female, median age 17 years, range 14-22 years), enrolled in the UK Adolescents and Adults Living with Perinatal HIV cohort study. Participants were eligible if they could identify one dose of medication taken and one dose they had missed in the previous two months. For each of the two episodes (one adherent, one non-adherent), behavioural factors (whom they were with, location, routine, day, reminders) and psychological factors at the time of the episode (information about medication, adherence motivation, perceived behavioural skills to adhere to medication - derived from the Information-Motivation-Behavioural Skills (IMB) Model - and affect) were assessed in a questionnaire. Non-adherence was significantly associated with weekend days (Friday to Sunday versus Monday to Thursday, p = .001), lack of routine (p = .004), and being out of the home (p = .003), but not with whom the young person was with or whether they were reminded to take medication. Non-adherence was associated with lower levels of behavioural skills (p ART, or ART motivation. The use of situationally specific strategies to enhance adherence in young people who take their

  5. Electron beam irradiating process for rendering rough or topographically irregular surface substrates smooth; and coated substrates produced thereby

    International Nuclear Information System (INIS)

    Nablo, S.V.

    1979-01-01

    This disclosure involves a novel process for instantaneous electron-beam curing of very thin low viscosity, solventless coating upon rough, irregular or textured surfaces of a substrate such as paper or the like. Through rather critical timing and energy adjustment procedures, the coating firmly adheres to the surface before the coating can conform to the roughness or texture contour or substantially penetrate into the surface. By this method a solidified very smooth outer surface is provided for the substrate that is particularly used for metalization and other finished layerings. (author)

  6. Adherence of Staphylococci to plastic, mesothelial cells and mesothelial extracellular matrix

    NARCIS (Netherlands)

    Betjes, M. G.; Tuk, C. W.; Struijk, D. G.; Krediet, R. T.; Arisz, L.; Beelen, R. H.

    1992-01-01

    In this study we have investigated whether mesothelial cells (MC) and mesothelial extracellular matrix (ECM) are suitable substrates for the adherence of Staphylococci. Mesothelial cells were isolated from the peritoneal dialysis effluent by making use of their lack of Fc-receptors and capacity to

  7. Suspension chemistry and electrophoretic deposition of zirconia electrolyte on conducting and non-conducting substrates

    International Nuclear Information System (INIS)

    Das, Debasish; Basu, Rajendra N.

    2013-01-01

    Graphical abstract: - Highlights: • Stable suspension of yttria stabilized zirconia (YSZ) obtained in isopropanol medium. • Suspension chemistry and process parameters for electrophoretic deposition optimized. • Deposited film quality changed with iodine and water (dispersants) concentration. • Dense YSZ film (∼5 μm) fabricated onto non-conducting porous NiO-YSZ anode substrate. - Abstract: Suspensions of 8 mol% yttria stabilized zirconia (YSZ) particulates in isopropanol medium are prepared using acetylacetone, iodine and water as dispersants. The effect of dispersants concentration on suspension stability, particle size distribution, electrical conductivity and pH of the suspensions are studied in detail to optimize the suspension chemistry. Electrophoretic deposition (EPD) has been conducted to produce thin and dense YSZ electrolyte films. Deposition kinetics have been studied in depth and good quality films on conducting substrate are obtained at an applied voltage of 15 V for 3 min. YSZ films are also fabricated on non-conducting NiO-YSZ anode substrate using a steel plate on the reverse side of the substrate. Upon co-firing at 1400 °C for 6 h a dense YSZ film of thickness ∼5 μm is obtained. Such a half cell (anode + electrolyte) can be used to fabricate a solid oxide fuel cell on applying a suitable cathode layer

  8. Effect of non-uniform Hall parameter on the electrode voltage drop in Faraday-type combustion MHD generators

    International Nuclear Information System (INIS)

    Gupta, G.P.; Rohatgi, V.K.

    1982-01-01

    Following a simplified approach, an expression is derived for the gas-dynamic voltage drop in a finitely segmented Faraday-type combustion MHD generator, taking into account the non-uniform Hall parameter across the channel. Combining the electrical sheath voltage drop, discussed briefly, with the gas-dynamic voltage drop, the effect of a non-uniform Hall parameter on the electrode voltage drop is studied using the theoretical and experimental input parameters of the Indian MHD channel test. The condition for the validity of the usual assumption of uniform Hall parameter across the channel is pointed out. Analysis of the measured electrode voltage drop predicts the real gas conductivity in the core to be in the range of 60 to 75 per cent of the theoretically calculated core conductivity. (author)

  9. Furthering patient adherence: a position paper of the international expert forum on patient adherence based on an internet forum discussion.

    NARCIS (Netherlands)

    Dulmen, S. van; Sluijs, E.; Dijk, L. van; Ridder, D. de; Heerdink, R.; Bensing, J.

    2008-01-01

    BACKGROUND: As the problem of patient non-adherence to treatment becomes ever greater and a solution appears hard to find, new ways have to be sought to tackle the issue. Given the weak theoretical underpinning of how to research the adherence problem, a fruitful step might be to find the most

  10. Co-adhesion and removal of adhering bacteria from salivary pellicles by three different modes of brushing

    NARCIS (Netherlands)

    Yang, J; Belder, GF; Busscher, HJ; Bos, R.R.M.

    2001-01-01

    This study compares removal of pairs of co-adhering and non-co-adhering oral actinomyces and streptococci by hand, electric and sonic brushing from salivary pellicles. In addition, re-deposition of a co-adhering and non-co-adhering streptococcal strain to brushed pellicles was studied. First,

  11. Dye-sensitized solar cells using graphene-based carbon nano composite as counter electrode

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyonkwang; Kim, Hyunkook; Hwang, Sookhyun; Jeon, Minhyon [Department of Nano Systems Engineering, Center of Nano Manufacturing, Inje University, Obang, Gimhae, Gyungnam 621-749 (Korea, Republic of); Choi, Wonbong [Department of Mechanical and Materials Engineering, Florida International University, Miami, FL 33174 (United States)

    2011-01-15

    We demonstrated a counter electrode in dye-sensitized solar cells (DSSCs) using the graphene-based multi-walled carbon nanotubes (GMWNTs) structure. Graphene layers were prepared by drop casting on a SiO{sub 2}/Si substrate and multi-walled carbon nanotubes (MWNTs) were synthesized on graphene layers using iron catalyst by chemical vapor deposition. The structural properties of GMWNTs were investigated by transmission electron microscope and field-emission scanning electron microscopy. The GMWNTs sheets were lifted off from the Si substrate by buffered oxide etching and were transplanted on fluorine-doped tin oxide glass by Van der Waals force as a counter electrode. From the electrochemical impedance spectroscopy and energy conversion efficiencies, electrochemical properties of GMWNTs were comparable with those of MWNTs counter electrode. The results suggested that GMWNTs were one of the candidates for a counter electrode for dye-sensitized solar cells. (author)

  12. Production of small U Alx alloy buttons in a non consumable electrode arc furnace

    International Nuclear Information System (INIS)

    Koshimizu, S.; Lima, L.F.C.P. de; Leal Neto, R.M.

    1994-01-01

    Some results are presented, concerning with composition and phases, in small buttons of U Al x (10 to 50 g) produced in a non consumable electrode arc furnace. The uranium metal utilised is natural one produced in the IPEN. The convenience of the fabrication of small buttons of U AL x is discussed. (author). 3 refs, 2 figs, 1 tab

  13. What strategies do ulcerative colitis patients employ to facilitate adherence?

    Directory of Open Access Journals (Sweden)

    Kawakami A

    2017-01-01

    Full Text Available Aki Kawakami,1,2 Makoto Tanaka,3 Makoto Naganuma,4 Shin Maeda,5 Reiko Kunisaki,1 Noriko Yamamoto-Mitani2 1Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Minami-ku, Yokohama, Japan; 2Department of Gerontological Home Care and Long-term Care Nursing, Graduate School of Medicine, University of Tokyo, Bunkyo-ku, Tokyo, Japan; 3Ramathibodi School of Nursing, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Ratchathewi, Bangkok, Thailand; 4Division of Gastroenterology and Hepatology, Keio University, Shinjuku-ku, Tokyo, Japan; 5Department of Gastroenterology, Yokohama City University Graduate School of Medicine, Kanazawa-ku, Yokohama, Japan Background: Overall, 30%–45% of patients with ulcerative colitis (UC are non-adherent and have difficulties taking their medications; this non-adherence increases the risk of clinical relapse 1.4- to 5.5-fold. This study aimed to clarify the strategies patients employ to facilitate adherence and determine whether the strategies had an impact on good adherence.Methods: This was a cross-sectional survey using a self-administered questionnaire and review of medical records. Patients diagnosed as having UC and attending one of the outpatient clinics of four urban hospitals from June 2009 to December 2012 were enrolled. A questionnaire was developed to identify the strategies patients employ to facilitate adherence and then administered to patients with UC. Adherence to 5-aminosalicylic acid was calculated, and univariate and multiple logistic regression analyses were performed to determine the strategies that were associated with good adherence.Results: The final analyses included 671 participants (mean age 40.2 years; 54.3% males. The valid response rate was 96.9%; 186 (27.7% participants were classified as non-adherent, the mean adherence rate being 86.1% (standard deviation [SD] 17.9. Seven strategies that patients employ to facilitate adherence were identified, the

  14. Patient survey to identify reasons for non-adherence and elicitation of quality of life concepts associated with immunosuppressant therapy in kidney transplant recipients

    Directory of Open Access Journals (Sweden)

    Muduma G

    2016-01-01

    Full Text Available Gorden Muduma,1 Francis C Shupo,2 Sophie Dam,3 Natalia A Hawken,3 Samuel Aballéa,3 Isaac Odeyemi,1 Mondher Toumi4 1Astellas Pharma Europe Ltd, Chertsey, 2Creativ-Ceutical Ltd, London, UK; 3Creativ-Ceutical Ltd, Paris, 4Public Health (EA 3279, Faculty of Medicine, Aix-Marseille University, Marseille, France Background: Renal transplantation (RT is considered the treatment of choice for end-stage renal disease compared to dialysis, offering better health-related quality of life (HRQoL and higher survival rates. However, immunosuppressants are essential for the long-term survival of kidney grafts and patients’ non-adherence to their medication leads to poor outcomes. Immunosuppressants can also significantly alter patients’ HRQoL because of their side effects and the complex chronic medication regimen they represent. Purpose: To elicit key concepts related to adherence to immunosuppressant therapy (IT and reasons for non-adherence in terms of patient reported outcomes, side effects, and the impact of the medication on HRQoL in RT population, including patient preference of once daily over twice-daily immunosuppressive regimen. Results were used to develop an IT-specific conceptual framework and provide suggestions for improving patients’ adherence to IT. Materials and methods: Interviews were conducted with three clinical experts to determine key concepts related to RT and immunosuppressants. Thirty-seven participants in four focus groups were asked to cite important concepts related to adherence and impact of IT on HRQoL and to rate them. Qualitative analysis was conducted to code participants’ responses. Results: Non-adherence among participants where admitted was unintentional. The reason for this included forgetfulness, interference with lifestyle, being asleep at the time the medication should be taken, change in routine, and impact of side effects. Overall, participants reported that the evening dose was more problematic to remember

  15. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording

    Directory of Open Access Journals (Sweden)

    Lei Ren

    2018-04-01

    Full Text Available Laser-direct writing (LDW and magneto-rheological drawing lithography (MRDL have been proposed for the fabrication of a flexible microneedle array electrode (MAE for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE, the electrode–skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG, electroencephalography (EEG and static electrocardiography (ECG signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

  16. Improving electrochemical performance of flexible thin film electrodes with micropillar array structures

    International Nuclear Information System (INIS)

    Myllymaa, Sami; Myllymaa, Katja; Lappalainen, Reijo; Pirinen, Sami; Pakkanen, Tapani A; Pakkanen, Tuula T; Suvanto, Mika

    2012-01-01

    For reliable function, bioelectrodes require a stable, low-impedance contact with the target tissue. In biosignal monitoring applications, in which low ion current densities are recorded, it is important to minimize electrode contact impedances. Recently, several flexible electrode concepts have been introduced for single-patient use. These electrodes conform well on the patient skin enabling an artifact-free, low-noise recording. In this study, polydimethylsiloxane (PDMS) elastomer was used as an electrode substrate material. One half of the substrates were surface-patterned with micropillars produced by using micro-working robot-made mold inserts and a replica molding technique. The substrates were subsequently coated with thin films of titanium (Ti), copper (Cu), silver (Ag) or silver–silver chloride (Ag/AgCl). Electrical impedance spectroscopy studies revealed that the micropillar structure caused statistically significant reductions in impedance modulus and phase for each coating candidate. The relative effect was strongest for pure Ag, for which the values of the real part (Z′) and the imaginary part (Z″) decreased to less than one tenth of the original (smooth) values. However, Ag/AgCl, as expected, proved to be a superior electrode material. Coating with chloride drastically reduced the interfacial impedance compared to pure Ag. Further significant reduction was achieved by the micropillars, since the phase angle declined from 10–13° (for smooth samples, f < 50 Hz) to a value as low as 5°. Equivalent circuit modeling was used to obtain a better understanding of phenomena occurring at various electrode–electrolyte interfaces. The knowledge obtained in this study will be exploited in the further development of flexible electrodes and miniaturized biointerfaces with improved electrochemical characteristics. (paper)

  17. Clinicians' adherence versus non adherence to practice guidelines in the management of patients with sarcoma: a cost-effectiveness assessment in two European regions

    Directory of Open Access Journals (Sweden)

    Perrier Lionel

    2012-03-01

    Full Text Available Abstract Background Although the management of sarcoma is improving, non adherence to clinical practice guidelines (CPGs remains high, mainly because of the low incidence of the disease and the variety of histological subtypes. Since little is known about the health economics of sarcoma, we undertook a cost-effectiveness analysis (within the CONnective TIssue CAncer NETwork, CONTICANET comparing costs and outcomes when clinicians adhered to CPGs and when they did not. Methods Patients studied had a histological diagnosis of sarcoma, were older than 15 years, and had been treated in the Rhône-Alpes region of France (in 2005/2006 or in the Veneto region of Italy (in 2007. Data collected retrospectively for the three years after diagnosis were used to determine relapse free survival and health costs (adopting the hospital's perspective and a microcosting approach. All costs were expressed in euros (€ at their 2009 value. A 4% annual discount rate was applied to both costs and effects. The incremental cost-effectiveness ratio (ICER was expressed as cost per relapse-free year gained when management was compliant with CPGs compared with when it was not. To capture uncertainty surrounding ICER, a probabilistic sensitivity analysis was performed based on a non-parametric bootstrap method. Results A total of 219 patients were included in the study. Compliance with CPGs was observed for 118 patients (54%. Average total costs reached 23,571 euros when treatment was in accordance with CPGs and 27,313 euros when it was not. In relation to relapse-free survival, compliance with CPGs strictly dominates non compliance, i.e. it is both less costly and more effective. Taking uncertainty into account, the probability that compliance with CPGs still strictly dominates was 75%. Conclusions Our findings should encourage physicians to increase their compliance with CPGs and healthcare administrators to invest in the implementation of CPGs in the management of

  18. Preparation, characterization and simulation studies of carbon nanotube electrodes for electrochemical energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Meissner, Frank; Endler, Ingolf [Fraunhofer-Institut fuer Keramische Technologien und Systeme (IKTS), Dresden (Germany); Lorrmann, Henning [Fraunhofer-Institut fuer Silicatforschung (ISC), Wuerzburg (Germany); Pastewka, Lars [Fraunhofer-Institut fuer Werkstoffmechanik (IWM), Freiburg im Breisgau (Germany)

    2010-07-01

    Chemical Vapor Deposition (CVD) was employed to synthesize multiwalled carbon nanotubes (MWCNT) on different carrier materials for electrode applications. In the field of electrochemical energy storage it is essential to grow MWCNT on conducting substrates. For this reason titanium nitride (TiN) layers as well as a copper foil were used as substrates. The MWCNT grown on TiN layers show diameters of about 20 nm and lengths up to 13 {mu}m. In the case of copper foil substrates a remarkably higher nanotube diameter of several tens of nanometers was found. First electrochemical characterization via cyclic voltammetry shows the potential of MWCNT as electrodes for energy storage applications. The CNT were measured in an organic carbonate electrolyte vs. a lithium counter electrode with various scan rates. Until now the preliminary investigations by cyclic voltammetry for electrodes consisting of aligned MWCNT on TiN showed a capacity of around 130 F g{sup -1} in the range of 1 - 3 V vs. Li/Li{sup +}. In support of the experiments we construct a one dimensional Poisson-Nernst-Planck (PNP) continuum model that has been shown to yield agreement with corresponding molecular dynamics simulations to model ion transport into these types of electrodes. Our simulations show that first the ions accumulate at the tips of the tubes because the inner volume of the electrodes is initially field-free. A homogeneous charge distribution is then established through diffusion. The PNP model is used to compute cyclic voltammograms which show qualitative agreement with the experiments. (orig.)

  19. Direct transparent electrode patterning on layered GaN substrate by screen printing of indium tin oxide nanoparticle ink for Eu-doped GaN red light-emitting diode

    International Nuclear Information System (INIS)

    Kashiwagi, Y.; Yamamoto, M.; Saitoh, M.; Takahashi, M.; Ohno, T.; Nakamoto, M.; Koizumi, A.; Fujiwara, Y.; Takemura, Y.; Murahashi, K.; Ohtsuka, K.; Furuta, S.

    2014-01-01

    Transparent electrodes were formed on Eu-doped GaN-based red-light-emitting diode (GaN:Eu LED) substrates by the screen printing of indium tin oxide nanoparticle (ITO np) inks as a wet process. The ITO nps with a mean diameter of 25 nm were synthesized by the controlled thermolysis of a mixture of indium complexes and tin complexes. After the direct screen printing of ITO np inks on GaN:Eu LED substrates and sintering at 850 °C for 10 min under atmospheric conditions, the resistivity of the ITO film was 5.2 mΩ cm. The fabricated LED up to 3 mm square surface emitted red light when the on-voltage was exceeded

  20. Direct transparent electrode patterning on layered GaN substrate by screen printing of indium tin oxide nanoparticle ink for Eu-doped GaN red light-emitting diode

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, Y., E-mail: kasiwagi@omtri.or.jp; Yamamoto, M.; Saitoh, M.; Takahashi, M.; Ohno, T.; Nakamoto, M. [Osaka Municipal Technical Research Institute, 1-6-50 Morinomiya, Joto-ku, Osaka 536-8553 (Japan); Koizumi, A.; Fujiwara, Y. [Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Takemura, Y.; Murahashi, K.; Ohtsuka, K. [Okuno Chemical Industries Co., Ltd., 2-1-25 Hanaten-nishi, Joto-ku, Osaka 536-0011 (Japan); Furuta, S. [Tomoe Works Co., Ltd., 7-13 Tsurumachi, Amagasaki 660-0092 (Japan)

    2014-12-01

    Transparent electrodes were formed on Eu-doped GaN-based red-light-emitting diode (GaN:Eu LED) substrates by the screen printing of indium tin oxide nanoparticle (ITO np) inks as a wet process. The ITO nps with a mean diameter of 25 nm were synthesized by the controlled thermolysis of a mixture of indium complexes and tin complexes. After the direct screen printing of ITO np inks on GaN:Eu LED substrates and sintering at 850 °C for 10 min under atmospheric conditions, the resistivity of the ITO film was 5.2 mΩ cm. The fabricated LED up to 3 mm square surface emitted red light when the on-voltage was exceeded.

  1. In vitro biocompatibility and electrical stability of thick-film platinum/gold alloy electrodes printed on alumina

    Science.gov (United States)

    Carnicer-Lombarte, Alejandro; Lancashire, Henry T.; Vanhoestenberghe, Anne

    2017-06-01

    Objective. High-density electrode arrays are a powerful tool in both clinical neuroscience and basic research. However, current manufacturing techniques require the use of specialised techniques and equipment, which are available to few labs. We have developed a high-density electrode array with customisable design, manufactured using simple printing techniques and with commercially available materials. Approach. Electrode arrays were manufactured by thick-film printing a platinum-gold alloy (Pt/Au) and an insulating dielectric on 96% alumina ceramic plates. Arrays were conditioned in serum and serum-free conditions, with and without 1 kHz, 200 µA, charge balanced stimulation for up to 21 d. Array biocompatibility was assessed using an extract assay and a PC-12 cell contact assay. Electrode impedance, charge storage capacity and charge injection capacity were before and after array conditioning. Main results. The manufactured Pt/Au electrodes have a highly porous surface and exhibit electrical properties comparable to arrays manufactured using alternative techniques. Materials used in array manufacture were found to be non-toxic to L929 fibroblasts by extract assay, and neuronal-like PC-12 cells adhered and extended neurites on the array surfaces. Arrays remained functional after long-term delivery of electrical pulses while exposed to protein-rich environments. Charge storage capacities and charge injection capacities increased following stimulation accounted for by an increase in surface index (real surface area) observed by vertical scanning interferometry. Further, we observed accumulation of proteins at the electrode sites following conditioning in the presence of serum. Significance. This study demonstrates the in vitro biocompatibility of commercially available thick-film printing materials. The printing technique is both simple and versatile, with layouts readily modified to produce customized electrode arrays. Thick-film electrode arrays are an

  2. Polymer Photovoltaic Cell Using TiO2/G-PEDOT Nanocomplex Film as Electrode

    Directory of Open Access Journals (Sweden)

    F. X. Xie

    2008-01-01

    Full Text Available Using TiO2/G-PEDOT (PEDOT/PSS doped with glycerol nanocomplex film as a substitute for metal electrode in organic photovoltaic cell is described. Indium tin oxide (ITO worked as cathode and TiO2/G-PEDOT nanocomplex works as anode. The thickness of TiO2 layer in nanocomplex greatly affects the act of this nonmetallic electrode of the device. To enhance its performance, this inverted organic photovoltaic cell uses another TiO2 layer as electron selective layer contacted to ITO coated glass substrates. All films made by solution processing techniques are coated on the transparent substrate (glass with a conducting film ITO. The efficiency of this solar cell is compared with the conventional device using Al as electrode.

  3. Silver-nickel oxide core-shell nanoparticle array electrode with enhanced lithium-storage performance

    International Nuclear Information System (INIS)

    Zhao, Wenjia; Du, Ning; Zhang, Hui; Yang, Deren

    2015-01-01

    We demonstrate the synthesis of Ag-NiO core-shell nanoparticle arrays via a one-step solution-immersion process and subsequent RF-sputtering technique. The Ag nanoparticle arrays on copper substrate are firstly prepared by a displacement reaction at mild temperature of 303K. Then, a NiO layer is deposited onto the surface of the Ag nanoparticles via RF-sputtering technique. When evaluated as an anode for lithium-ion batteries, the Ag-NiO core-shell electrode shows higher capacity and better cycling performance than the planar NiO electrode. The in-situ synthesized Ag nanoparticles can enhance the interfacial strength between the active material and substrate, andimprove the electrical conductivity of the electrode, which may be responsible for the enhanced performance

  4. Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging

    Directory of Open Access Journals (Sweden)

    Amar Prasad Gupta

    2017-07-01

    Full Text Available We report the design, fabrication and characterization of a carbon nanotube enabled open-type X-ray system for medical imaging. We directly grew the carbon nanotubes used as electron emitter for electron gun on a non-polished raw metallic rectangular-rounded substrate with an area of 0.1377 cm2 through a plasma enhanced chemical vapor deposition system. The stable field emission properties with triode electrodes after electrical aging treatment showed an anode emission current of 0.63 mA at a gate field of 7.51 V/μm. The 4.5-inch cubic shape open type X-ray system was developed consisting of an X-ray aperture, a vacuum part, an anode high voltage part, and a field emission electron gun including three electrodes with focusing, gate and cathode electrodes. Using this system, we obtained high-resolution X-ray images accelerated at 42–70 kV voltage by digital switching control between emitter and ground electrode.

  5. Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging.

    Science.gov (United States)

    Gupta, Amar Prasad; Park, Sangjun; Yeo, Seung Jun; Jung, Jaeik; Cho, Chonggil; Paik, Sang Hyun; Park, Hunkuk; Cho, Young Chul; Kim, Seung Hoon; Shin, Ji Hoon; Ahn, Jeung Sun; Ryu, Jehwang

    2017-07-29

    We report the design, fabrication and characterization of a carbon nanotube enabled open-type X-ray system for medical imaging. We directly grew the carbon nanotubes used as electron emitter for electron gun on a non-polished raw metallic rectangular-rounded substrate with an area of 0.1377 cm² through a plasma enhanced chemical vapor deposition system. The stable field emission properties with triode electrodes after electrical aging treatment showed an anode emission current of 0.63 mA at a gate field of 7.51 V/μm. The 4.5-inch cubic shape open type X-ray system was developed consisting of an X-ray aperture, a vacuum part, an anode high voltage part, and a field emission electron gun including three electrodes with focusing, gate and cathode electrodes. Using this system, we obtained high-resolution X-ray images accelerated at 42-70 kV voltage by digital switching control between emitter and ground electrode.

  6. Adherence to a web-based pre-treatment for phobias in outpatient clinics

    DEFF Research Database (Denmark)

    Kok, Robin Niels; Beekman, Aartjan T F; Cuijpers, Pim

    2017-01-01

    Background Non-adherence in Internet interventions is a persistent and multifaceted issue and potentially limits the applicability and effectiveness of these interventions. Factors that influence non-adherence are poorly understood, especially in outpatient samples with more complex symptoms. Obj...

  7. The complexity of evaluating and increasing adherence in inflammatory bowel disease

    DEFF Research Database (Denmark)

    Weimers, Petra; Burisch, Johan; Munkholm, Pia

    2017-01-01

    . Nonetheless, adherence remains a common and complex issue in IBD care. Patient characteristics such as young age, male sex and employment has previously been verified as possible predictors of non-adherence. Additionally, evaluating adherence in itself is a challenge since both accurate and easy...

  8. Highly transparent, low-haze, hybrid cellulose nanopaper as electrodes for flexible electronics

    KAUST Repository

    Xu, Xuezhu

    2016-06-01

    Paper is an excellent candidate to replace plastics as a substrate for flexible electronics due to its low cost, renewability and flexibility. Cellulose nanopaper (CNP), a new type of paper made of nanosized cellulose fibers, is a promising substrate material for transparent and flexible electrodes due to its potentially high transparency and high mechanical strength. Although CNP substrates can achieve high transparency, they are still characterized by high diffuse transmittance and small direct transmittance, resulting in high optical haze of the substrates. In this study, we proposed a simple methodology for large-scale production of high-transparency, low-haze CNP comprising both long cellulose nanofibrils (CNFs) and short cellulose nanocrystals (CNCs). By varying the CNC/CNF ratio in the hybrid CNP, we could tailor its total transmittance, direct transmittance and diffuse transmittance. By increasing the CNC content, the optical haze of the hybrid CNP could be decreased and its transparency could be increased. The direct transmittance and optical haze of the CNP were 75.1% and 10.0%, respectively, greatly improved from the values of previously reported CNP (31.1% and 62.0%, respectively). Transparent, flexible electrodes were fabricated by coating the hybrid CNP with silver nanowires (AgNWs). The electrodes showed a low sheet resistance (minimum 1.2 Ω sq-1) and a high total transmittance (maximum of 82.5%). The electrodes were used to make a light emitting diode (LED) assembly to demonstrate their potential use in flexible displays. © 2016 The Royal Society of Chemistry.

  9. Effect of substrate nature on the electrochemical deposition of calcium-deficient hydroxyapatites

    International Nuclear Information System (INIS)

    Gualdrón-Reyes, A F; Cabanzo, R; Meléndez, A M; Domínguez-Vélez, V; Morales-Morales, J A

    2017-01-01

    Calcium phosphates were obtained by reducing nitrate ions to produce hydroxide ions on TiO 2 /stainless steel and TiO 2 /titanium electrodes. TiO 2 coatings on metallic substrates were prepared by sol-gel dip-coating method. The morphology of deposits was observed by FESEM. Chemical nature of calcium phosphate deposits was identified by Raman micro-spectroscopy and FESEM/EDS microanalysis. Electrochemical behavior of nitrate and nitrite reduction on stainless steel and titanium electrodes was studied by linear sweep voltammetry. In addition, voltammetric study of the calcium phosphate electrodeposition on both electrodes was performed. From these measurements was selected the potential to form a calcium phosphate. A catalytic current associated to nitrate reduction reaction was obtained for stainless steel electrode, leading to significant deposition of calcium phosphate. Ca/P ratio for both substrates was less than 1.67. The formation of calcium deficient hydroxyapatite was confirmed by Raman spectroscopy. (paper)

  10. Considerations on sample holder design and custom-made non-polarizable electrodes for Spectral Induced Polarization measurements on unsaturated soils

    Science.gov (United States)

    Kaouane, C.; Chouteau, M. C.; Fauchard, C.; Cote, P.

    2014-12-01

    Spectral Induced Polarization (SIP) is a geophysical method sensitive to water content, saturation and grain size distribution. It could be used as an alternative to nuclear probes to assess the compaction of soils in road works. To evaluate the potential of SIP as a practical tool, we designed an experiment for complex conductivity measurements on unsaturated soil samples.Literature presents a large variety of sample holders and designs, each depending on the context. Although we might find some precise description about the sample holder, exact replication is not always possible. Furthermore, the potential measurements are often done using custom-made Ag/AgCl electrodes and very few indications are given on their reliability with time and temperature. Our objective is to perform complex conductivity measurements on soil samples compacted in a PVC cylindrical mould (10 cm-long, 5 cm-diameter) according to geotechnical standards. To expect homogeneous current density, electrical current is transmitted through the sample via chambers filled with agar gel. Agar gel is a good non-polarizable conductor within the frequency range (1 mHz -20kHz). Its electrical properties are slightly known. We measured increasing of agar-agar electrical conductivity in time. We modelled the influence of this variation on the measurement. If the electrodes are located on the sample, it is minimized. Because of the dimensions at stake and the need for simple design, potential electrodes are located outside the sample, hence the gel contributes to the measurements. Since the gel is fairly conductive, we expect to overestimate the sample conductivity. Potential electrodes are non-polarizable Ag/AgCl electrodes. To avoid any leakage, the KCl solution in the electrodes is replaced by saturated KCl-agar gel. These electrodes are low cost and show a low, stable, self-potential (<1mV). In addition, the technique of making electrode can be easily reproduced and storage and maintenance are simple

  11. The effect of micro-ECoG substrate footprint on the meningeal tissue response

    Science.gov (United States)

    Schendel, Amelia A.; Nonte, Michael W.; Vokoun, Corinne; Richner, Thomas J.; Brodnick, Sarah K.; Atry, Farid; Frye, Seth; Bostrom, Paige; Pashaie, Ramin; Thongpang, Sanitta; Eliceiri, Kevin W.; Williams, Justin C.

    2014-08-01

    Objective. There is great interest in designing implantable neural electrode arrays that maximize function while minimizing tissue effects and damage. Although it has been shown that substrate geometry plays a key role in the tissue response to intracortically implanted, penetrating neural interfaces, there has been minimal investigation into the effect of substrate footprint on the tissue response to surface electrode arrays. This study investigates the effect of micro-electrocorticography (micro-ECoG) device geometry on the longitudinal tissue response. Approach. The meningeal tissue response to two micro-ECoG devices with differing geometries was evaluated. The first device had each electrode site and trace individually insulated, with open regions in between, while the second device had a solid substrate, in which all 16 electrode sites were embedded in a continuous insulating sheet. These devices were implanted bilaterally in rats, beneath cranial windows, through which the meningeal tissue response was monitored for one month after implantation. Electrode site impedance spectra were also monitored during the implantation period. Main results. It was observed that collagenous scar tissue formed around both types of devices. However, the distribution of the tissue growth was different between the two array designs. The mesh devices experienced thick tissue growth between the device and the cranial window, and minimal tissue growth between the device and the brain, while the solid device showed the opposite effect, with thick tissue forming between the brain and the electrode sites. Significance. These data suggest that an open architecture device would be more ideal for neural recording applications, in which a low impedance path from the brain to the electrode sites is critical for maximum recording quality.

  12. Unravelling adherence to prophylaxis in haemophilia : A patients' perspective

    NARCIS (Netherlands)

    Schrijvers, L. H.; Kars, M. C.; Beijlevelt-van der Zande, M.; Peters, M.; Schuurmans, M. J.; Fischer, K.

    Given the lifelong therapy in haemophilia patients, insight in non-adherence behaviour from a patient perspective is important to understand patients' difficulties with the following treatment recommendations. The aim of this study was to clarify the process underlying adherence (behaviour) to

  13. Flexible transparent electrode

    Science.gov (United States)

    Demiryont, Hulya; Shannon, Kenneth C., III; Moorehead, David; Bratcher, Matthew

    2011-06-01

    This paper presents the properties of the EclipseTECTM transparent conductor. EclipseTECTM is a room temperature deposited nanostructured thin film coating system comprised of metal-oxide semiconductor elements. The system possesses metal-like conductivity and glass-like transparency in the visible region. These highly conductive TEC films exhibit high shielding efficiency (35dB at 1 to 100GHz). EclipseTECTM can be deposited on rigid or flexible substrates. For example, EclipseTECTM deposited on polyethylene terephthalate (PET) is extremely flexible that can be rolled around a 9mm diameter cylinder with little or no reduction in electrical conductivity and that can assume pre-extension states after an applied stress is relieved. The TEC is colorless and has been tailored to have high visible transmittance which matches the eye sensitivity curve and allows the viewing of true background colors through the coating. EclipseTECTM is flexible, durable and can be tailored at the interface for applications such as electron- or hole-injecting OLED electrodes as well as electrodes in flexible displays. Tunable work function and optical design flexibility also make EclipseTECTM well-suited as a candidate for grid electrode replacement in next-generation photovoltaic cells.

  14. Doped polymer electrodes for high performance ferroelectric capacitors on plastic substrates

    KAUST Repository

    Khan, M. A.; Bhansali, Unnat Sampatraj; Zhang, Xixiang; Saleh, Moussa M.; Odeh, Ihab; Alshareef, Husam N.

    2012-01-01

    classical ferroelectric and dielectric responses, including series resistance effects. The improved device characteristics obtained using highly conducting doped PEDOT:PSS suggest that it may be used both as an electrode and as global interconnect for all

  15. Comparative study of the interface composition of TiN and TiCN hard coatings on high speed steel substrates obtained by arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Roman, E. (Lab. de Fisica de Superficies, Inst. de Ciencia de Materiales, CSIC, Madrid (Spain)); Segovia, J.L. de (Lab. de Fisica de Superficies, Inst. de Ciencia de Materiales, CSIC, Madrid (Spain)); Alberdi, A. (TEKNIKER, Asociacion de Investigacion Tecnologica, Eibar (Spain)); Calvo, J. (TEKNIKER, Asociacion de Investigacion Tecnologica, Eibar (Spain)); Laucirica, J. (TEKNIKER, Asociacion de Investigacion Tecnologica, Eibar (Spain))

    1993-05-15

    In this paper the composition of the interface of TiN and TiCN hard coatings deposited onto high speed steel substrates obtained by the arc discharge technique is studied using Auger electron spectroscopy at two different substrate temperatures, 520 K and 720 K. The low temperature (520 K) TiN coating developed an oxygen phase at the interface, producing a weak adherence of 40 N, while the high temperature coatings (720 K) had a less intense oxygen phase, giving a greater adherence to the substrate of 60 N. TiCN coatings at 520 K are characterized by a low oxygen intensity at the interface. However, their adherence of 50 N is lower than the value of 60 N for the high temperature TiN coatings and is independent of the substrate temperature. (orig.)

  16. Conducting polymers based counter electrodes for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Veerender, P., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Saxena, Vibha, E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Gusain, Abhay, E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Jha, P., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Koiry, S. P., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Chauhan, A. K., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Aswal, D. K., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Gupta, S. K., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com [Technical Physics Division, Bhabha Atomic Research Centre, Mumbai - 400085 (India)

    2014-04-24

    Conducting polymer films were synthesized and employed as an alternative to expensive platinum counter electrodes for dye-sensitized solar cells. poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) thin films were spin-coated and polypyrrole films were electrochemically deposited via cyclic voltammetry method on ITO substrates. The morphology of the films were imaged by SEM and AFM. These films show good catalytic activity towards triiodide reduction as compared to Pt/FTO electrodes. Finally the photovoltaic performance of DSSC fabricated using N3 dye were compared with PT/FTO, PEDOT/ITO, and e-PPy counter electrodes.

  17. Controlled Fabrication of Metallic Electrodes with Atomic Separation

    DEFF Research Database (Denmark)

    Morpurgo, A.; Robinson, D.; M. Marcus, C.

    1998-01-01

    We report a new technique for fabricating metallic electrodes on insulating substrates with separations on the 1 nm scale. The fabrication technique, which combines lithographic and electrochemical methods, provides atomic resolution without requiring sophisticated instrumentation. The process is...

  18. Microbial electrosynthesis: understanding and strengthening microbe-electrode interactions

    DEFF Research Database (Denmark)

    Tremblay, Pier-Luc; Höglund, Daniel; Ammam, Fariza

    2014-01-01

    in the last decade that could significantly change the current ways of synthesizing chemicals. MES is a process in which electroautotrophic microbes reduce CO2 to multicarbon organics using electrical current as a source of electron. Electricity necessary for MES can be harvested from renewable resources...... relying on co-cultures and investigating extracellular electron transfer from the cathode to the microbes are some of the strategies that we are implementing to transform MES into a commercially viable technology....... such as solar energy, wind turbine or wastewater treatment processes. The net outcome is that renewable energy get store in the covalent bonds of valuable chemicals synthesized from greenhouse gas. However, low electron transferrates from the electrode to microbes, poor adherence of cells on the electrode...

  19. Barriers to and determinants of medication adherence among hypertensive patients attended National Health Service Hospital, Sunderland

    Directory of Open Access Journals (Sweden)

    Muhammad Umair Khan

    2014-01-01

    Full Text Available Background: Hypertension is a silent killer, a time bomb in both the developed and developing nations of the world. It is one of the most significant risk factors for cardiovascular morbidity and mortality resulting from target-organ damage to blood vessels in the heart, brain, kidney and eyes. Adherence to long-term therapy for chronic illnesses like hypertension is an important tool to enhance the effectiveness of pharmacotherapy. Objective: The two objectives of this study were to evaluate the extent and reasons of non-adherence in patients attended National Health Service (NHS Hospital, Sunderland. Materials and Methods: The study was conducted for 4 months in the out-patient department of NHS Hospital. A total of 200 patients were selected randomly for this study. Morisky′s Medication Adherence Scale was used to assess the adherence rate and the reason of non-adherence. Data were entered and analyzed using Microsoft Excel 2010. Results: The overall adherence rate was found to be 79% (n = 158. Adherence rate in females were low was compared with their male counterparts (74.7% vs. 85.7%. The higher rate of adherence was found in age group of 30-40 years (82%, n = 64. The major intentional and non-intentional reason of non-adherence was side-effects and forgetfulness respectively. Conclusion: Overall, more than three-fourth of the hypertensive participants were found to be adherent to their treatment. On the basis of factors associated with non-adherence, it is analyzed that suitable therapy must be designed for patients individually to increase medication adherence and its effectiveness.

  20. Two Ti13-oxo-clusters showing non-compact structures, film electrode preparation and photocurrent properties.

    Science.gov (United States)

    Hou, Jin-Le; Luo, Wen; Wu, Yin-Yin; Su, Hu-Chao; Zhang, Guang-Lin; Zhu, Qin-Yu; Dai, Jie

    2015-12-14

    Two benzene dicarboxylate (BDC) and salicylate (SAL) substituted titanium-oxo-clusters, Ti13O10(o-BDC)4(SAL)4(O(i)Pr)16 (1) and Ti13O10(o-BDC)4(SAL-Cl)4(O(i)Pr)16 (2), are prepared by one step in situ solvothermal synthesis. Single crystal analysis shows that the two Ti13 clusters take a paddle arrangement with an S4 symmetry. The non-compact (non-sphere) structure is stabilized by the coordination of BDC and SAL. Film photoelectrodes are prepared by the wet coating process using the solution of the clusters and the photocurrent response properties of the electrodes are studied. It is found that the photocurrent density and photoresponsiveness of the electrodes are related to the number of coating layers and the annealing temperature. Using ligand coordinated titanium-oxo-clusters as the molecular precursors of TiO2 anatase films is found to be effective due to their high solubility, appropriate stability in solution and hence the easy controllability.

  1. Transparent resistive switching memory using aluminum oxide on a flexible substrate

    International Nuclear Information System (INIS)

    Yeom, Seung-Won; Kim, Tan-Young; Ha, Hyeon Jun; Ju, Byeong-Kwon; Shin, Sang-Chul; Shim, Jae Won; Lee, Yun-Hi

    2016-01-01

    Resistive switching memory (ReRAM) has attracted much attention in recent times owing to its fast switching, simple structure, and non-volatility. Flexible and transparent electronic devices have also attracted considerable attention. We therefore fabricated an Al 2 O 3 -based ReRAM with transparent indium-zinc-oxide (IZO) electrodes on a flexible substrate. The device transmittance was found to be higher than 80% in the visible region (400–800 nm). Bended states (radius = 10 mm) of the device also did not affect the memory performance because of the flexibility of the two transparent IZO electrodes and the thin Al 2 O 3 layer. The conduction mechanism of the resistive switching of our device was explained by ohmic conduction and a Poole–Frenkel emission model. The conduction mechanism was proved by oxygen vacancies in the Al 2 O 3 layer, as analyzed by x-ray photoelectron spectroscopy analysis. These results encourage the application of ReRAM in flexible and transparent electronic devices. (letter)

  2. Transparent resistive switching memory using aluminum oxide on a flexible substrate

    Science.gov (United States)

    Yeom, Seung-Won; Shin, Sang-Chul; Kim, Tan-Young; Ha, Hyeon Jun; Lee, Yun-Hi; Shim, Jae Won; Ju, Byeong-Kwon

    2016-02-01

    Resistive switching memory (ReRAM) has attracted much attention in recent times owing to its fast switching, simple structure, and non-volatility. Flexible and transparent electronic devices have also attracted considerable attention. We therefore fabricated an Al2O3-based ReRAM with transparent indium-zinc-oxide (IZO) electrodes on a flexible substrate. The device transmittance was found to be higher than 80% in the visible region (400-800 nm). Bended states (radius = 10 mm) of the device also did not affect the memory performance because of the flexibility of the two transparent IZO electrodes and the thin Al2O3 layer. The conduction mechanism of the resistive switching of our device was explained by ohmic conduction and a Poole-Frenkel emission model. The conduction mechanism was proved by oxygen vacancies in the Al2O3 layer, as analyzed by x-ray photoelectron spectroscopy analysis. These results encourage the application of ReRAM in flexible and transparent electronic devices.

  3. Gold leaf counter electrodes for dye-sensitized solar cells

    Science.gov (United States)

    Shimada, Kazuhiro; Toyoda, Takeshi

    2018-03-01

    In this study, a gold leaf 100 nm thin film is used as the counter electrode in dye-sensitized solar cells. The traditional method of hammering gold foil to obtain a thin gold leaf, which requires only small amounts of gold, was employed. The gold leaf was then attached to the substrate using an adhesive to produce the gold electrode. The proposed approach for fabricating counter electrodes is demonstrated to be facile and cost-effective, as opposed to existing techniques. Compared with electrodes prepared with gold foil and sputtered gold, the gold leaf counter electrode demonstrates higher catalytic activity with a cobalt-complex electrolyte and higher cell efficiency. The origin of the improved performance was investigated by surface morphology examination (scanning electron microscopy), various electrochemical analyses (cyclic voltammetry, linear sweep voltammetry, and electrochemical impedance spectroscopy), and crystalline analysis (X-ray diffractometry).

  4. Finding the minimal intervention needed for sustained mammography adherence.

    Science.gov (United States)

    Gierisch, Jennifer M; DeFrank, Jessica T; Bowling, J Michael; Rimer, Barbara K; Matuszewski, Jeanine M; Farrell, David; Skinner, Celette Sugg

    2010-10-01

    Regular adherence to mammography screening saves lives, yet few women receive regular mammograms. RCT. Participants were recruited through a state employee health plan. All were women aged 40-75 years and had recent mammograms prior to enrollment (n=3547). Data were collected from 2004 to 2009. Trial tested efficacy of a two-step adaptively-designed intervention to increase mammography adherence over 4 years. The first intervention step consisted of three reminder types: enhanced usual care reminders (EUCR); enhanced letter reminders (ELR); both delivered by mail, and automated telephone reminders (ATR). After delivery of reminders, women who became off-schedule in any of the 4 years received a second step of supplemental interventions. Three supplemental intervention arms contained priming letters and telephone counseling: barriers only (BarriCall); barriers plus positive consequences of getting mammograms (BarriConCall+); and barriers plus negative consequences of not getting mammograms (BarriConCall-). Average cumulative number of days non-adherent to mammography over 4 years based on annual screening guidelines (analyses conducted in 2009). All reminders performed equally well in reducing number of days of non-adherence. Women randomized to receive supplemental interventions had significantly fewer days of non-adherence compared to women who received EUCR (p=0.0003). BarrConCall+ and BarrConCall- conditions did not significantly differ in days non-adherent compared to women in the barriers-only condition (BarriCon). The minimal intervention needed for sustained mammography use is a combination of a reminder followed by a priming letter and barrier-specific telephone counseling for women who become off-schedule. Additional costs associated with supplemental interventions should be considered by organizations deciding which interventions to use. NCT01148875. Copyright © 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Influence of route of administration/drug formulation and other factors on adherence to treatment in rheumatoid arthritis (pain related) and dyslipidemia (non-pain related).

    Science.gov (United States)

    Fautrel, Bruno; Balsa, Alejandro; Van Riel, Piet; Casillas, Marta; Capron, Jean-Philippe; Cueille, Carine; de la Torre, Inmaculada

    2017-07-01

    A comprehensive review was performed to investigate the effect of route of administration on medication adherence and persistence in rheumatoid arthritis (RA) and to compare adherence/persistence with oral medications between RA and a non-painful disease (dyslipidemia). Comprehensive database searches were performed to identify studies investigating medication adherence and/or persistence in adults with RA receiving conventional synthetic or biologic agents. Similar searches were performed for studies of patients with dyslipidemia receiving statins. Studies had to be published after 1998 in English and involve ≥6 months' follow up. Adherence and persistence were compared between the different routes of drug administration in RA, and between the two diseases for oral medications. A total of 35 and 28 papers underwent data extraction for RA and dyslipidemia, respectively. Within the constraints of the analysis, adherence and persistence rates appeared broadly similar for the different routes of drug administration in RA. Adherence to oral medications was also broadly similar across the two diseases, but persistence was lower in dyslipidemia. Poor adherence has clinical consequences in both diseases: greater disease activity and risk of flare in RA, and increased serum cholesterol levels and risk of heart and cerebrovascular disease in dyslipidemia. Over 1-3 years, poor adherence to biologic RA medications led to increased resource use and medical costs but lower total direct costs due to reduced biologic drug costs. Conversely, poor adherence to dyslipidemia medications resulted in increased total direct costs. In both diseases, adherence improved with patient education/support. The route of drug administration and the symptomatic (pain) nature of the disease do not appear to be dominant factors for drug adherence or persistence in RA. The wide range of adherence and persistence values and definitions across studies made comparisons between drug formulations and

  6. What are validated self-report adherence scales really measuring?: a systematic review.

    Science.gov (United States)

    Nguyen, Thi-My-Uyen; La Caze, Adam; Cottrell, Neil

    2014-03-01

    Medication non-adherence is a significant health problem. There are numerous methods for measuring adherence, but no single method performs well on all criteria. The purpose of this systematic review is to (i) identify self-report medication adherence scales that have been correlated with comparison measures of medication-taking behaviour, (ii) assess how these scales measure adherence and (iii) explore how these adherence scales have been validated. Cinahl and PubMed databases were used to search articles written in English on the development or validation of medication adherence scales dating to August 2012. The search terms used were medication adherence, medication non-adherence, medication compliance and names of each scale. Data such as barriers identified and validation comparison measures were extracted and compared. Sixty articles were included in the review, which consisted of 43 adherence scales. Adherence scales include items that either elicit information regarding the patient's medication-taking behaviour and/or attempts to identify barriers to good medication-taking behaviour or beliefs associated with adherence. The validation strategies employed depended on whether the focus of the scale was to measure medication-taking behaviour or identify barriers or beliefs. Supporting patients to be adherent requires information on their medication-taking behaviour, barriers to adherence and beliefs about medicines. Adherence scales have the potential to explore these aspects of adherence, but currently there has been a greater focus on measuring medication-taking behaviour. Selecting the 'right' adherence scale(s) requires consideration of what needs to be measured and how (and in whom) the scale has been validated. © 2013 The British Pharmacological Society.

  7. Hypertension: adherence to treatment in rural Bangladesh – findings from a population-based study

    Science.gov (United States)

    Khanam, Masuma Akter; Lindeboom, Wietze; Koehlmoos, Tracey Lynn Perez; Alam, Dewan Shamsul; Niessen, Louis; Milton, Abul Hasnat

    2014-01-01

    Background Poor adherence has been identified as the main cause of failure to control hypertension. Poor adherence to antihypertensive treatment is a significant cardiovascular risk factor, which often remains unrecognized. There are no previous studies that examined adherence with antihypertensive medication or the characteristics of the non-adherent patients in Bangladesh. Objective This paper aims to describe hypertension and factors affecting adherence to treatment among hypertensive persons in rural Bangladesh. Design The study population included 29,960 men and women aged 25 years and older from three rural demographic surveillance sites of the International Center for Diarrheal Disease Research, Bangladesh (icddr,b): Matlab, Abhoynagar, and Mirsarai. Data was collected by a cross-sectional design on diagnostic provider, initial, and current treatment. Discontinuation of medication at the time of interview was defined as non-adherence to treatment. Results The prevalence of hypertension was 13.67%. Qualified providers diagnosed only 53.5% of the hypertension (MBBS doctors 46.1 and specialized doctors 7.4%). Among the unqualified providers, village doctors diagnosed 40.7%, and others (nurse, health worker, paramedic, homeopath, spiritual healer, and pharmacy man) each diagnosed less than 5%. Of those who started treatment upon being diagnosed with hypertension, 26% discontinued the use of medication. Age, sex, education, wealth, and type of provider were independently associated with non-adherence to medication. More men discontinued the treatment than women (odds ratio [OR] 1.74, confidence interval [CI] 1.48–2.04). Non-adherence was greater when hypertension was diagnosed by unqualified providers (OR 1.52, CI 1.31–1.77). Hypertensive patients of older age, least poor quintile, and higher education were less likely to be non-adherent. Patients with cardiovascular comorbidity were also less likely to be non-adherent to antihypertensive medication (OR 0

  8. Cu mesh for flexible transparent conductive electrodes.

    Science.gov (United States)

    Kim, Won-Kyung; Lee, Seunghun; Hee Lee, Duck; Hee Park, In; Seong Bae, Jong; Woo Lee, Tae; Kim, Ji-Young; Hun Park, Ji; Chan Cho, Yong; Ryong Cho, Chae; Jeong, Se-Young

    2015-06-03

    Copper electrodes with a micromesh/nanomesh structure were fabricated on a polyimide substrate using UV lithography and wet etching to produce flexible transparent conducting electrodes (TCEs). Well-defined mesh electrodes were realized through the use of high-quality Cu thin films. The films were fabricated using radio-frequency (RF) sputtering with a single-crystal Cu target--a simple but innovative approach that overcame the low oxidation resistance of ordinary Cu. Hybrid Cu mesh electrodes were fabricated by adding a capping layer of either ZnO or Al-doped ZnO. The sheet resistance and the transmittance of the electrode with an Al-doped ZnO capping layer were 6.197 ohm/sq and 90.657%, respectively, and the figure of merit was 60.502 × 10(-3)/ohm, which remained relatively unchanged after thermal annealing at 200 °C and 1,000 cycles of bending. This fabrication technique enables the mass production of large-area flexible TCEs, and the stability and high performance of Cu mesh hybrid electrodes in harsh environments suggests they have strong potential for application in smart displays and solar cells.

  9. A novel high-performance counter electrode for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Wang Guiqiang; Lin Ruifeng; Lin Yuan; Li Xueping; Zhou Xiaowen; Xiao Xurui

    2005-01-01

    A novel Pt counter electrode for dye-sensitized solar cells (DSC) was prepared by thermal decomposition of H 2 PtCl 6 on NiP-plated glass substrate. The charge-transfer kinetic properties of the platinized NiP-plated glass electrode (Pt/NiP electrode) for triiodide reduction were studied by electrochemical impedance spectroscopy. Pt/NiP electrode has the advantage over the platinized FTO conducting glass electrode (Pt/FTO electrode) in increasing the light reflectance and reducing the sheet resistance leading to improve the light harvest efficiency and the fill factor of the dye-sensitized solar cells effectively. The photon-to-current efficiency and the overall conversion efficiency of DSC using Pt/NiP counter electrode is increased by 20% and 33%, respectively, compared to that of using Pt/FTO counter electrode. Examination of the anodic dissolution and the long-term test on the variation of charge-transfer resistance indicates the good stability of the Pt/NiP electrode in the electrolyte containing iodide/triiodide

  10. Aminoacid polymorphisms of insulin receptor substrate-1 in non-insulin-dependent diabetes mellitus

    DEFF Research Database (Denmark)

    Almind, K; Bjørbaek, C; Vestergaard, H

    1993-01-01

    Since relative or absolute insulin deficiency and insulin insensitivity are involved in the aetiology of non-insulin-dependent diabetes mellitus (NIDDM), we examined whether patients with NIDDM exhibit genetic variability in the coding region of insulin receptor substrate-1 (IRS-1), a candidate...

  11. Reasons for non-adherence to vaccination at mother and child care clinics (MCCs) in Lambaréné, Gabon.

    Science.gov (United States)

    Schwarz, Norbert G; Gysels, Marjolein; Pell, Christopher; Gabor, Julian; Schlie, Meike; Issifou, Saadou; Lell, Bertrand; Kremsner, Peter G; Grobusch, Martin P; Pool, Robert

    2009-08-27

    The aim of this paper is to explore attitudes of mothers towards childhood vaccinations and reasons for non-attendance and non-adherence to mother-child clinics (MCCs). Forty in-depth interviews with mothers of children under 5 years of age revealed positive attitudes towards vaccination that seem at odds with the region's observed low vaccination coverage. Important reasons for MCC non-attendance included distance to the MCC, transport costs, negative experiences at MCCs (such as interactions with unfriendly staff) and mothers' feeling of shame provoked by different, often poverty-associated reasons such as attending the clinic with a dirty or poorly clothed child.

  12. Levels and correlates of non-adherence to WHO recommended inter-birth intervals in Rufiji, Tanzania

    Directory of Open Access Journals (Sweden)

    Exavery Amon

    2012-12-01

    Full Text Available Abstract Background Poorly spaced pregnancies have been documented worldwide to result in adverse maternal and child health outcomes. The World Health Organization (WHO recommends a minimum inter-birth interval of 33 months between two consecutive live births in order to reduce the risk of adverse maternal and child health outcomes. However, birth spacing practices in many developing countries, including Tanzania, remain scantly addressed. Methods Longitudinal data collected in the Rufiji Health and Demographic Surveillance System (HDSS from January 1999 to December 2010 were analyzed to investigate birth spacing practices among women of childbearing age. The outcome variable, non-adherence to the minimum inter-birth interval, constituted all inter-birth intervals Results A total of 15,373 inter-birth intervals were recorded from 8,980 women aged 15–49 years in Rufiji district over the follow-up period of 11 years. The median inter-birth interval was 33.4 months. Of the 15,373 inter-birth intervals, 48.4% were below the WHO recommended minimum length of 33 months between two live births. Non-adherence was associated with younger maternal age, low maternal education, multiple births from the preceding pregnancy, non-health facility delivery of the preceding birth, being an in-migrant resident, multi-parity and being married. Conclusion Generally, one in every two inter-birth intervals among 15–49 year-old women in Rufiji district is poorly spaced, with significant variations by socio-demographic and behavioral characteristics of mothers and newborns. Maternal, newborn and child health services should be improved with a special emphasis on community- and health facility-based optimum birth spacing education in order to enhance health outcomes of mothers and their babies, especially in rural settings.

  13. Barriers and facilitators of antiretroviral therapy adherence in rural ...

    African Journals Online (AJOL)

    Multivariable logistic regression was conducted to examine the associations between household economic factors and adherence. Our findings suggest that the role of economic status on adherence appears to be a function of the economic component. Debt and non-farming-related occupation were consistently associated ...

  14. A nafion coated capacitive humidity sensor on a flexible PET substrate

    KAUST Repository

    Sapsanis, Christos

    2017-03-07

    This paper reports a simple and low-cost technique for fabricating low-power capacitive humidity sensors without the use of a cleanroom environment. A maskless laser engraving system was utilized to fabricate two different gold electrode structures, interdigitated electrodes and Hilbert\\'s fifth-order fractal. The capacitive structures were implemented on a flexible PET substrate. The usage of Nafion, a well-known polymer for its hydrophilic properties as a sensing film, was attempted on the PET and outperformed the current efforts in flexible substrates. Its humidity sensing properties were evaluated in an automated gas setup with a relative humidity (RH %) ranging from 15% to 95 %.

  15. A nafion coated capacitive humidity sensor on a flexible PET substrate

    KAUST Repository

    Sapsanis, Christos; Buttner, Ulrich; Omran, Hesham; Belmabkhout, Youssef; Shekhah, Osama; Eddaoudi, Mohamed; Salama, Khaled N.

    2017-01-01

    This paper reports a simple and low-cost technique for fabricating low-power capacitive humidity sensors without the use of a cleanroom environment. A maskless laser engraving system was utilized to fabricate two different gold electrode structures, interdigitated electrodes and Hilbert's fifth-order fractal. The capacitive structures were implemented on a flexible PET substrate. The usage of Nafion, a well-known polymer for its hydrophilic properties as a sensing film, was attempted on the PET and outperformed the current efforts in flexible substrates. Its humidity sensing properties were evaluated in an automated gas setup with a relative humidity (RH %) ranging from 15% to 95 %.

  16. Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cunguang Lou

    2016-11-01

    Full Text Available This paper describes the development of a graphene-based dry flexible electrocardiography (ECG electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM, and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults.

  17. Two character traits associated with adherence to long term therapies.

    Science.gov (United States)

    Reach, Gérard

    2012-10-01

    Adherence is defined as the adequacy between the behaviours of patients and their medical prescriptions. Adherence is a general behaviour, which can explain why patients in the placebo arm of randomised clinical trials have a lower mortality rate when they are adherent. We propose that this behaviour is related to two character traits: patience (capacity to give priority to the future) and, more provocatively, obedience. To support this claim, we bring arguments from the literature and from two published personal studies. We previously showed that type 2 diabetic patients who respond as non-adherers to a questionnaire on adherence to medication and to whom one proposes a fictitious monetary choice between receiving 500 euros today or waiting one year to receive 1500 euros never make the remote choice. We also showed that obese diabetic patients who declare that they do not fasten their seat belt when they are seated in the rear of a car are more often non-adherent concerning medication than those patients who claim that they follow this road safety recommendation. Thus, one of the roles of empowerment and patient education could be to encourage the patients, if they wish it, to replace passive adherence behaviours with conscious active choices. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Trends in CPAP adherence over twenty years of data collection: a flattened curve.

    Science.gov (United States)

    Rotenberg, Brian W; Murariu, Dorian; Pang, Kenny P

    2016-08-19

    Obstructive sleep apnea (OSA) is a common disorder, and continuous airway positive pressure (CPAP) is considered to be the gold standard of therapy. CPAP however is known to have problems with adherence, with many patients eventually abandoning the device. The purpose of this paper is to assess secular trends in CPAP adherence over the long term to see if there have been meaningful improvements in adherence in light of the multiple interventions proposed to do so. A comprehensive systematic literature review was conducted using the Medline-Ovid, Embase, and Pubmed databases, searching for data regarding CPAP adherence over a twenty year timeframe (1994-2015). Data was assessed for quality and then extracted. The main outcome measure was reported CPAP non-adherence. Secondary outcomes included changes in CPAP non-adherence when comparing short versus long-term, and changes in terms of behavioral counseling. Eighty-two papers met study inclusion/exclusion criteria. The overall CPAP non-adherence rate based on a 7-h/night sleep time that was reported in studies conducted over the twenty year time frame was 34.1 %. There was no significant improvement over the time frame. Behavioral intervention improved adherence rates by ~1 h per night on average. The rate of CPAP adherence remains persistently low over twenty years worth of reported data. No clinically significant improvement in CPAP adherence was seen even in recent years despite efforts toward behavioral intervention and patient coaching. This low rate of adherence is problematic, and calls into question the concept of CPAP as gold-standard of therapy for OSA.

  19. Developing consensus-based policy solutions for medicines adherence for Europe: a delphi study

    Science.gov (United States)

    2012-01-01

    Background Non-adherence to prescribed medication is a pervasive problem that can incur serious effects on patients’ health outcomes and well-being, and the availability of resources in healthcare systems. This study aimed to develop practical consensus-based policy solutions to address medicines non-adherence for Europe. Methods A four-round Delphi study was conducted. The Delphi Expert Panel comprised 50 participants from 14 countries and was representative of: patient/carers organisations; healthcare providers and professionals; commissioners and policy makers; academics; and industry representatives. Participants engaged in the study remotely, anonymously and electronically. Participants were invited to respond to open questions about the causes, consequences and solutions to medicines non-adherence. Subsequent rounds refined responses, and sought ratings of the relative importance, and operational and political feasibility of each potential solution to medicines non-adherence. Feedback of individual and group responses was provided to participants after each round. Members of the Delphi Expert Panel and members of the research group participated in a consensus meeting upon completion of the Delphi study to discuss and further refine the proposed policy solutions. Results 43 separate policy solutions to medication non-adherence were agreed by the Panel. 25 policy solutions were prioritised based on composite scores for importance, and operational and political feasibility. Prioritised policy solutions focused on interventions for patients, training for healthcare professionals, and actions to support partnership between patients and healthcare professionals. Few solutions concerned actions by governments, healthcare commissioners, or interventions at the system level. Conclusions Consensus about practical actions necessary to address non-adherence to medicines has been developed for Europe. These actions are also applicable to other regions. Prioritised

  20. A systematic review of immunosuppressant adherence interventions in transplant recipients: Decoding the streetlight effect.

    Science.gov (United States)

    Duncan, S; Annunziato, R A; Dunphy, C; LaPointe Rudow, D; Shneider, B L; Shemesh, E

    2018-02-01

    Non-adherence to immunosuppressant medications is an important risk factor for graft dysfunction. To evaluate the effectiveness of adherence-enhancing interventions, we reviewed adherence intervention studies in solid organ transplant recipients (all ages). Using the following databases: PsycINFO, PubMed, Scopus, and ScienceDirect, we identified 41 eligible studies. Only three non-randomized trials showed a possible positive effect on objective indicators of transplant outcomes (such as rejection, liver enzyme levels, kidney function). None of the 21 RCTs showed an improvement in transplant outcomes. Three studies showed a higher rate of adverse events in the intervention group as compared with controls, although this may be related to ascertainment bias. Improvement in adherence as measured indirectly (eg, with electronic monitoring devices) was not aligned with effects on transplant outcomes. We conclude that adherence interventions, to date, have largely been ineffective in improving transplant outcomes. To improve this track record, intervention efforts may wish to concentrate on non-adherent patients (rather than use convenience sampling, which excludes many of the patients who need the intervention), use direct measures of adherence to guide the interventions, and employ strategies that are intensive and yet engaging enough to ensure that non-adherent patients are able to participate. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Improving yield of PZT piezoelectric devices on glass substrates

    Science.gov (United States)

    Johnson-Wilke, Raegan L.; Wilke, Rudeger H. T.; Cotroneo, Vincenzo; Davis, William N.; Reid, Paul B.; Schwartz, Daniel A.; Trolier-McKinstry, Susan

    2012-10-01

    The proposed SMART-X telescope includes adaptive optics systems that use piezoelectric lead zirconate titanate (PZT) films deposited on flexible glass substrates. Several processing constraints are imposed by current designs: the crystallization temperature must be kept below 550 °C, the total stress in the film must be minimized, and the yield on 1 cm2 actuator elements should be work, RF magnetron sputtering was used to deposit films since chemical solution deposition (CSD) led to warping of large area flexible glass substrates. A PZT 52/48 film that wasdeposited at 4 mTorr and annealed at 550 °C for 24 hours showed no detectable levels of either PbO or pyrochlore second phases. Large area electrodes (1cm x 1 cm) were deposited on 4" glass substrates. Initially, the yield of the devices was low, however, two methods were employed to increase the yield to near 100 %. The first method included a more rigorous cleaning to improve the continuity of the Pt bottom electrode. The second method was to apply 3 V DC across the capacitor structure to burn out regions of defective PZT. The result of this latter method essentially removed conducting filaments in the PZT but left the bulk of the material undamaged. By combining these two methods, the yield on the large area electrodes improved from < 10% to nearly 100%.

  2. Adherence of Moraxella bovis to cell cultures of bovine origin.

    Science.gov (United States)

    Annuar, B O; Wilcox, G E

    1985-09-01

    The adherence of five strains of Moraxella bovis to cell cultures was investigated. M bovis adhered to cultures of bovine corneal epithelial and Madin-Darby bovine kidney cells but not to cell types of non-bovine origin. Both piliated and unpiliated strains adhered but piliated strains adhered to a greater extent than unpiliated strains. Antiserum against pili of one strain inhibited adherence of piliated strains but caused only slight inhibition of adherence to the unpiliated strains. Treatment of bacteria with magnesium chloride caused detachment of pili from the bacterial cell and markedly inhibited adherence of piliated strains but caused only slight inhibition of adherence by the unpiliated strains. The results suggested that adhesion of piliated strains to cell cultures was mediated via pili but that adhesins other than pili may be involved in the attachment of unpiliated strains of M bovis to cells.

  3. All-organic polymer-dispersed liquid crystal light-valves integrated with electroactive anthraquinone-2-sulfonate-doped polypyrrole thin films as driving electrodes

    International Nuclear Information System (INIS)

    Wang, Pen-Cheng; Yu, Jing-Yu; Li, Kuan-Hsun

    2011-01-01

    Highlights: → Fabrication of flexible semi-transparent all-polymer electrodes under ambient conditions without using a CVD system. → Characterization of the above electrodes based on anthraquinone-2-sulfonate-doped polypyrrole thin films. → Demonstration of all-organic liquid crystal light-valves with polypyrrole thin films as the driving electrodes. - Abstract: All-organic PDLC (polymer-dispersed liquid crystal) light-valves using all-polymer conductive substrates containing thin films of polypyrrole doped with anthraquinone-2-sulfonate (AQSA - ) as the driving electrodes were fabricated in this study. The all-polymer conductive substrates were prepared under ambient conditions by in situ depositing polypyrrole thin films on blank flexible poly(ethylene terephthalate), or PET, substrates from aqueous media in which oxidative polymerization of pyrrole was taking place. The obtained flexible all-polymer conductive substrates were semi-transparent with cohesive coatings of AQSA - doped polypyrrole thin films (thickness ∼55 nm). The all-polymer flexible conductive substrates had sheet resistivity ∼40 kΩ □ -1 and T% transparency against air ∼78% at 600 nm. The light-valves fabricated using the above all-polymer conductive substrates showed ∼50% transparency against air at 600 nm when 4 V μm -1 electric field was applied.

  4. Stretchable, Transparent, and Stretch-Unresponsive Capacitive Touch Sensor Array with Selectively Patterned Silver Nanowires/Reduced Graphene Oxide Electrodes.

    Science.gov (United States)

    Choi, Tae Young; Hwang, Byeong-Ung; Kim, Bo-Yeong; Trung, Tran Quang; Nam, Yun Hyoung; Kim, Do-Nyun; Eom, Kilho; Lee, Nae-Eung

    2017-05-31

    Stretchable and transparent touch sensors are essential input devices for future stretchable transparent electronics. Capacitive touch sensors with a simple structure of only two electrodes and one dielectric are an established technology in current rigid electronics. However, the development of stretchable and transparent capacitive touch sensors has been limited due to changes in capacitance resulting from dimensional changes in elastomeric dielectrics and difficulty in obtaining stretchable transparent electrodes that are stable under large strains. Herein, a stretch-unresponsive stretchable and transparent capacitive touch sensor array was demonstrated by employing stretchable and transparent electrodes with a simple selective-patterning process and by carefully selecting dielectric and substrate materials with low strain responsivity. A selective-patterning process was used to embed a stretchable and transparent silver nanowires/reduced graphene oxide (AgNWs/rGO) electrode line into a polyurethane (PU) dielectric layer on a polydimethylsiloxane (PDMS) substrate using oxygen plasma treatment. This method provides the ability to directly fabricate thin film electrode lines on elastomeric substrates and can be used in conventional processes employed in stretchable electronics. We used a dielectric (PU) with a Poisson's ratio smaller than that of the substrate (PDMS), which prevented changes in the capacitance resulting from stretching of the sensor. The stretch-unresponsive touch sensing capability of our transparent and stretchable capacitive touch sensor has great potential in wearable electronics and human-machine interfaces.

  5. Facile 3D Metal Electrode Fabrication for Energy Applications via Inkjet Printing and Shape Memory Polymer

    International Nuclear Information System (INIS)

    Roberts, R C; Wu, J; Li, D C; Hau, N Y; Chang, Y H; Feng, S P

    2014-01-01

    This paper reports on a simple 3D metal electrode fabrication technique via inkjet printing onto a thermally contracting shape memory polymer (SMP) substrate. Inkjet printing allows for the direct patterning of structures from metal nanoparticle bearing liquid inks. After deposition, these inks require thermal curing steps to render a stable conductive film. By printing onto a SMP substrate, the metal nanoparticle ink can be cured and substrate shrunk simultaneously to create 3D metal microstructures, forming a large surface area topology well suited for energy applications. Polystyrene SMP shrinkage was characterized in a laboratory oven from 150-240°C, resulting in a size reduction of 1.97-2.58. Silver nanoparticle ink was patterned into electrodes, shrunk, and the topology characterized using scanning electron microscopy. Zinc-Silver Oxide microbatteries were fabricated to demonstrate the 3D electrodes compared to planar references. Characterization was performed using 10M potassium hydroxide electrolyte solution doped with zinc oxide (57g/L). After a 300s oxidation at 3Vdc, the 3D electrode battery demonstrated a 125% increased capacity over the reference cell. Reference cells degraded with longer oxidations, but the 3D electrodes were fully oxidized for 4 hours, and exhibited a capacity of 5.5mA-hr/cm 2 with stable metal performance

  6. A Solution Processed Flexible Nanocomposite Electrode with Efficient Light Extraction for Organic Light Emitting Diodes

    Science.gov (United States)

    Li, Lu; Liang, Jiajie; Chou, Shu-Yu; Zhu, Xiaodan; Niu, Xiaofan; Zhibinyu; Pei, Qibing

    2014-03-01

    Highly efficient organic light emitting diodes (OLEDs) based on multiple layers of vapor evaporated small molecules, indium tin oxide transparent electrode, and glass substrate have been extensively investigated and are being commercialized. The light extraction from the exciton radiative decay is limited to less than 30% due to plasmonic quenching on the metallic cathode and the waveguide in the multi-layer sandwich structure. Here we report a flexible nanocomposite electrode comprising single-walled carbon nanotubes and silver nanowires stacked and embedded in the surface of a polymer substrate. Nanoparticles of barium strontium titanate are dispersed within the substrate to enhance light extraction efficiency. Green polymer OLED (PLEDs) fabricated on the nanocomposite electrode exhibit a maximum current efficiency of 118 cd/A at 10,000 cd/m2 with the calculated external quantum efficiency being 38.9%. The efficiencies of white PLEDs are 46.7 cd/A and 30.5%, respectively. The devices can be bent to 3 mm radius repeatedly without significant loss of electroluminescent performance. The nanocomposite electrode could pave the way to high-efficiency flexible OLEDs with simplified device structure and low fabrication cost.

  7. Medication adherence as a learning process: insights from cognitive psychology.

    Science.gov (United States)

    Rottman, Benjamin Margolin; Marcum, Zachary A; Thorpe, Carolyn T; Gellad, Walid F

    2017-03-01

    Non-adherence to medications is one of the largest contributors to sub-optimal health outcomes. Many theories of adherence include a 'value-expectancy' component in which a patient decides to take a medication partly based on expectations about whether it is effective, necessary, and tolerable. We propose reconceptualising this common theme as a kind of 'causal learning' - the patient learns whether a medication is effective, necessary, and tolerable, from experience with the medication. We apply cognitive psychology theories of how people learn cause-effect relations to elaborate this causal-learning challenge. First, expectations and impressions about a medication and beliefs about how a medication works, such as delay of onset, can shape a patient's perceived experience with the medication. Second, beliefs about medications propagate both 'top-down' and 'bottom-up', from experiences with specific medications to general beliefs about medications and vice versa. Third, non-adherence can interfere with learning about a medication, because beliefs, adherence, and experience with a medication are connected in a cyclic learning problem. We propose that by conceptualising non-adherence as a causal-learning process, clinicians can more effectively address a patient's misconceptions and biases, helping the patient develop more accurate impressions of the medication.

  8. Glucose Oxidation on Gold-modified Copper Electrode

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jieun; Pyo, Sung Gyu; Son, Hyungbin; Kim, Sookil [Chung-Ang Univ., Seoul (Korea, Republic of); Ahn, Sang Hyun; Son, Hyungbin [Korea Institute of Science and Technology, Seoul (Korea, Republic of)

    2013-09-15

    The activities of Au-modified Cu electrodes toward glucose oxidation are evaluated according to their fabrication conditions and physico-chemical properties. The Au-modified Cu electrodes are fabricated by the galvanic displacement of Au on a Cu substrate and the characteristics of the Au particles are controlled by adjusting the displacement time. From the glucose oxidation tests, it is found that the Au modified Cu has superior activity to the pure Au or Cu film, which is evidenced by the negative shift in the oxidation potential and enhanced current density during the electrochemical oxidation. Though the activity of the Au nanoparticles is a contributing factor, the enhanced activity of the Au-modified Cu electrode is due to the increased oxidation number of Cu through the electron transfer from Cu to more electronegative Au. The depletion of electron in Cu facilitates the oxidation of glucose. The stability of the Au-modified Cu electrode was also studied by chronoamperometry.

  9. Scalable Coating and Properties of Transparent, Flexible, Silver Nanowire Electrodes

    KAUST Repository

    Hu, Liangbing

    2010-05-25

    We report a comprehensive study of transparent and conductive silver nanowire (Ag NW) electrodes, including a scalable fabrication process, morphologies, and optical, mechanical adhesion, and flexibility properties, and various routes to improve the performance. We utilized a synthesis specifically designed for long and thin wires for improved performance in terms of sheet resistance and optical transmittance. Twenty Ω/sq and ∼ 80% specular transmittance, and 8 ohms/sq and 80% diffusive transmittance in the visible range are achieved, which fall in the same range as the best indium tin oxide (ITO) samples on plastic substrates for flexible electronics and solar cells. The Ag NW electrodes show optical transparencies superior to ITO for near-infrared wavelengths (2-fold higher transmission). Owing to light scattering effects, the Ag NW network has the largest difference between diffusive transmittance and specular transmittance when compared with ITO and carbon nanotube electrodes, a property which could greatly enhance solar cell performance. A mechanical study shows that Ag NW electrodes on flexible substrates show excellent robustness when subjected to bending. We also study the electrical conductance of Ag nanowires and their junctions and report a facile electrochemical method for a Au coating to reduce the wire-to-wire junction resistance for better overall film conductance. Simple mechanical pressing was also found to increase the NW film conductance due to the reduction of junction resistance. The overall properties of transparent Ag NW electrodes meet the requirements of transparent electrodes for many applications and could be an immediate ITO replacement for flexible electronics and solar cells. © 2010 American Chemical Society.

  10. Scalable Coating and Properties of Transparent, Flexible, Silver Nanowire Electrodes

    KAUST Repository

    Hu, Liangbing; Kim, Han Sun; Lee, Jung-Yong; Peumans, Peter; Cui, Yi

    2010-01-01

    We report a comprehensive study of transparent and conductive silver nanowire (Ag NW) electrodes, including a scalable fabrication process, morphologies, and optical, mechanical adhesion, and flexibility properties, and various routes to improve the performance. We utilized a synthesis specifically designed for long and thin wires for improved performance in terms of sheet resistance and optical transmittance. Twenty Ω/sq and ∼ 80% specular transmittance, and 8 ohms/sq and 80% diffusive transmittance in the visible range are achieved, which fall in the same range as the best indium tin oxide (ITO) samples on plastic substrates for flexible electronics and solar cells. The Ag NW electrodes show optical transparencies superior to ITO for near-infrared wavelengths (2-fold higher transmission). Owing to light scattering effects, the Ag NW network has the largest difference between diffusive transmittance and specular transmittance when compared with ITO and carbon nanotube electrodes, a property which could greatly enhance solar cell performance. A mechanical study shows that Ag NW electrodes on flexible substrates show excellent robustness when subjected to bending. We also study the electrical conductance of Ag nanowires and their junctions and report a facile electrochemical method for a Au coating to reduce the wire-to-wire junction resistance for better overall film conductance. Simple mechanical pressing was also found to increase the NW film conductance due to the reduction of junction resistance. The overall properties of transparent Ag NW electrodes meet the requirements of transparent electrodes for many applications and could be an immediate ITO replacement for flexible electronics and solar cells. © 2010 American Chemical Society.

  11. Direct synthesis of porous NiO nanowall arrays on conductive substrates for supercapacitor application

    International Nuclear Information System (INIS)

    Zhu, Jianhui; Jiang, Jian; Liu, Jingping; Ding, Ruimin; Ding, Hao; Feng, Yamin; Wei, Guangming; Huang, Xintang

    2011-01-01

    Porous NiO nanowall arrays (NWAs) grown on flexible Fe-Co-Ni alloy have been successfully synthesized by using nullaginite (Ni 2 (OH) 2 CO 3 ) as precursor and investigated as supercapacitor electrodes. In details, we adopted a simple hydrothermal method to realize Ni 2 (OH) 2 CO 3 NWAs and examined their robust mechanical adhesion to substrate via a long-time ultrasonication test. Porous NiO NWAs were then obtained by a post-calcination towards precursors at 500 o C in nitrogen atmosphere. Electrochemical properties of as-synthesized NiO NWAs were evaluated by cyclic voltammetry and galvanostatic charge/discharge; porous NiO NWAs electrode delivered a specific capacitance of 270 F/g (0.67 A/g); even at high current densities, the electrode could still deliver a high capacitance up to 236 F/g (13.35 A/g). Meanwhile, it exhibited excellent cycle lifetime with ∼93% specific capacitance kept after 4000 cycles. These results suggest that as-made porous NiO NWAs electrode is a promising candidate for future thin-film supercapacitors and other microelectronic systems. -- Graphical abstract: Porous NiO nanowall arrays (NWAs) grown on alloy substrate have been made using nullaginite as precursor and studied as supercapacitor electrodes. Porous nanowalls interconnected with each other resulting in the formation of extended-network architectures and exhibited excellent capacitor properties. NiO NWAs electrode delivered a capacitance of 270 F/g (0.67 A/g); even at high current density, the electrode could still deliver a high capacitance up to 236 F/g (13.35 A/g). Besides, it exhibited excellent cycle lifetime with ∼93% capacitance kept after 4000 cycles. These remarkable results made it possible for mass production of NiO NWAs and future thin-film microelectronic applications. Display Omitted Research highlights: → Large-scale nullaginite (Ni 2 (OH) 2 CO 3 ) nanowall arrays (NWAs) have been synthesized on flexible alloy substrate by a facile hydrothermal method.

  12. Graphene-Vertically Aligned Carbon Nanotube Hybrid on PDMS as Stretchable Electrodes.

    Science.gov (United States)

    Ding, Junjun; Fu, Shichen; Zhang, Runzhi; Boon, Eric Peter; Lee, Woo; Fisher, Frank T; Yang, Eui-Hyeok

    2017-09-11

    Stretchable electrodes are a critical component for flexible electronics such as displays, energy devices, and wearable sensors. Carbon nanotubes (CNTs) and graphene have been considered for flexible electrode applications, due to their mechanical strength, high carrier mobility, and excellent thermal conductivity. Vertically aligned carbon nanotubes (VACNTs) provide the possibility to serve as interconnects to graphene sheets as stretchable electrodes that could maintain high electrical conductivity under large tensile strain. In this work, a graphene oxide (GO) -VACNT hybrid on a PDMS substrate was demonstrated. Here, 50 μm long VACNTs were grown on a Si/SiO2 wafer substrate via atmospheric pressure chemical vapor deposition (APCVD). VACNTs were directly transferred by delamination from the Si/SiO2 to a semi-cured PDMS substrate, ensuring strong adhesion between VACNTs and PDMS upon full curing of the PDMS. GO ink was then printed on the surface of the VACNT carpet and thermally reduced to reduced graphene oxide (rGO). The sheet resistance of the rGO-VACNT hybrid was measured under uniaxial tensile strains up to 300% applied to the substrate. Under applied strain, the rGO-VACNT hybrid maintained a sheet resistant of 386±55 Ω/sq. Cyclic stretching of the rGO-VACNT hybrid was performed with up to 50 cycles at 100% maximum tensile strain, showing no increase in sheet resistance. These results demonstrate promising performance of the rGO-VACNT hybrid for flexible electronics applications. © 2017 IOP Publishing Ltd.

  13. Graphene—vertically aligned carbon nanotube hybrid on PDMS as stretchable electrodes

    Science.gov (United States)

    Ding, Junjun; Fu, Shichen; Zhang, Runzhi; Boon, Eric; Lee, Woo; Fisher, Frank T.; Yang, Eui-Hyeok

    2017-11-01

    Stretchable electrodes are a critical component for flexible electronics such as displays, energy devices, and wearable sensors. Carbon nanotubes (CNTs) and graphene have been considered for flexible electrode applications, due to their mechanical strength, high carrier mobility, and excellent thermal conductivity. Vertically aligned carbon nanotubes (VACNTs) provide the possibility to serve as interconnects to graphene sheets as stretchable electrodes that could maintain high electrical conductivity under large tensile strain. In this work, a graphene oxide (GO)-VACNT hybrid on a PDMS substrate was demonstrated. Here, 50 μm long VACNTs were grown on a Si/SiO2 wafer substrate via atmospheric pressure chemical vapor deposition. VACNTs were directly transferred by delamination from the Si/SiO2 to a semi-cured PDMS substrate, ensuring strong adhesion between VACNTs and PDMS upon full curing of the PDMS. GO ink was then printed on the surface of the VACNT carpet and thermally reduced to reduced graphene oxide (rGO). The sheet resistance of the rGO-VACNT hybrid was measured under uniaxial tensile strains up to 300% applied to the substrate. Under applied strain, the rGO-VACNT hybrid maintained a sheet resistant of 386 ± 55 Ω/sq. Cyclic stretching of the rGO-VACNT hybrid was performed with up to 50 cycles at 100% maximum tensile strain, showing no increase in sheet resistance. These results demonstrate promising performance of the rGO-VACNT hybrid for flexible electronics applications.

  14. Risk-factors for non-adherence to antiretroviral therapy Fatores preditivos de não-adesão à terapia antiretroviral

    Directory of Open Access Journals (Sweden)

    Márcia Cristina Fraga Silva

    2009-06-01

    Full Text Available Cross-sectional study analyzed as case-control to identify risk factors for non-adherence to antiretroviral therapy. We studied 412 out-clinics HIV infected subjects of three public hospitals of Recife, Pernambuco. The objective was to examine the association between non-adherence to the antiretroviral therapy and biological, social-behavior and demographics and economic factors, factors related to the disease and/or treatment, factors related to life habits and depression symptoms. Variables significantly associated with non-adherence to antiretroviral therapy were: time elapsed since HIV diagnosis (p = 0.002, daily dose (p = 0.046, use of alcohol (p = 0.030 and past drug use (p = 0.048, and borderline p-values were found for educational level (p = 0.093 and family monthly income (p = 0.08. In the multivariable analysis, the factors that remained in the final model were family monthly income, time period with HIV infection and use of alcohol. No association was observed between non-adherence to antiretroviral therapy and gender, age, sexual orientation, marital status, educational level and place of residence. Based on our results and the local situation we suggest: assessment of social needs; training of partners and/or families on supporting adherence, creation of "adherence groups" to motivate and to reassure patients on the benefits of treatment; counseling and/or psychotherapy for alcohol drinkers.Estudo transversal com análise tipo caso-controle, que avaliou 412 pacientes de hospitais públicos do Recife - PE, com o objetivo de identificar fatores preditivos de não adesão à terapia antiretroviral. Verificou-se associação entre não adesão à terapia antiretroviral e aspectos biológicos, sócio-comportamentais e demográficos, econômicos, relacionados à doença e ao tratamento, aos hábitos de vida e aos distúrbios do humor. Variáveis com associação estatisticamente significante com não adesão na análise univariada foram

  15. A SUBSTRATE AND A METHOD FOR DETERMINING AND/OR MONITORING ELECTROPHYSIOLOGICAL PROPERTIES OF ION CHANNELS

    DEFF Research Database (Denmark)

    2001-01-01

    The present invention relates to a substrate and a method for obtaining an electrophysiological measuring configuration in which a cell forms a high resistive seal (giga-seal) around a measuring electrode making it suitable for determining and monitoring a current flow through the cell membrane...... and reference electrodes formed by wafer processing technology. The electrodes are adapted to conduct a current between them by delivery of ions by one electrode and receipt of ions by the other electrode and are typically silver/silver halide electrodes. This allows for effective and fast measuring of cells...

  16. Preditores de não aderência ao tratamento na psicoterapia psicanalítica de crianças Predictors of treatment non-adherence in child psychoanalytic psychotherapy

    Directory of Open Access Journals (Sweden)

    Marina Bento Gastaud

    2011-01-01

    Full Text Available INTRODUÇÃO: A alta prevalência de interrupções nas fases iniciais do atendimento psicoterapêutico tem sido demonstrada em estudos nacionais e internacionais. Estudos com pacientes adultos têm demonstrado variáveis sociodemográficas e clínicas associadas à aderência/não aderência à psicoterapia, porém a literatura voltada a crianças é escassa. OBJETIVO:Examinar a associação entre variáveis sociodemográficas/clínicas e aderência/não aderência à psicoterapia psicanalítica de crianças. MÉTODO: Trata-se de estudo documental, retrospectivo, realizado a partir dos prontuários de todas as crianças atendidas em duas instituições de atendimento psicológico em Porto Alegre entre 1979 e 2007. RESULTADOS: Foram analisados 2.106 prontuários, sendo que 1.083 compuseram a amostra final da presente investigação. Destas, 21,5% não aderiram ao tratamento. A variável fonte de encaminhamento mostrou-se associada ao desfecho, demonstrando que o encaminhamento à psicoterapia por psiquiatras é um fator protetor à não aderência ao tratamento, enquanto que o encaminhamento pela família é um fator de risco para a não aderência. CONCLUSÃO: Conhecer o perfil das crianças que não aderem à psicoterapia possibilita aos terapeutas o estabelecimento de técnicas de intervenção em fases iniciais do tratamento, a fim de facilitar a adesão da família à psicoterapia da criança. Abandono e não aderência à psicoterapia devem ser entendidos por clínicos e pesquisadores como fenômenos distintos, tendo em vista que apresentam preditores diferentes.INTRODUCTION: The high prevalence of interruptions in the early stages of psychotherapeutic treatment has been shown in national and international studies. Studies conducted with adults have demonstrated association between social, demographic, and clinical characteristics and adherence/non-adherence to psychotherapy; however, literature focused on children is scarce. OBJECTIVE: To

  17. Effect of annealing over optoelectronic properties of graphene based transparent electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Shriniwas, E-mail: sniwas89@gmail.com; Kaur, Inderpreet, E-mail: inderpreety@yahoo.co.in [Academy of Scientific and Innovative Research- Central Scientific Instruments Organisation (AcSIR-CSIO), Sector-30C, Chandigarh (India); Council of Scientific and Industrial Research- Central Scientific Instruments Organisation (CSIR-CSIO), Sector-30C, Chandigarh (India)

    2016-04-13

    Graphene, an atom–thick two dimensional graphitic material have led various fundamental breakthroughs in the field of science and technology. Due to their exceptional optical, physical and electrical properties, graphene based transparent electrodes have shown several applications in organic light emitting diodes, solar cells and thin film transistors. Here, we are presenting effect of annealing over optoelectronic properties of graphene based transparent electrodes. Graphene based transparent electrodes have been prepared by wet chemical approach over glass substrates. After fabrication, these electrodes tested for optical transmittance in visible region. Sheet resistance was measured using four probe method. Effect of thermal annealing at 200 °C was studied over optical and electrical performance of these electrodes. Optoelectronic performance was judged from ratio of direct current conductivity to optical conductivity (σ{sub dc}/σ{sub opt}) as a figure of merit for transparent conductors. The fabricated electrodes display good optical and electrical properties. Such electrodes can be alternatives for doped metal oxide based transparent electrodes.

  18. Effect of annealing over optoelectronic properties of graphene based transparent electrodes

    Science.gov (United States)

    Yadav, Shriniwas; Kaur, Inderpreet

    2016-04-01

    Graphene, an atom-thick two dimensional graphitic material have led various fundamental breakthroughs in the field of science and technology. Due to their exceptional optical, physical and electrical properties, graphene based transparent electrodes have shown several applications in organic light emitting diodes, solar cells and thin film transistors. Here, we are presenting effect of annealing over optoelectronic properties of graphene based transparent electrodes. Graphene based transparent electrodes have been prepared by wet chemical approach over glass substrates. After fabrication, these electrodes tested for optical transmittance in visible region. Sheet resistance was measured using four probe method. Effect of thermal annealing at 200 °C was studied over optical and electrical performance of these electrodes. Optoelectronic performance was judged from ratio of direct current conductivity to optical conductivity (σdc/σopt) as a figure of merit for transparent conductors. The fabricated electrodes display good optical and electrical properties. Such electrodes can be alternatives for doped metal oxide based transparent electrodes.

  19. Reasons for non-adherence to obesity treatment in children and adolescents

    Directory of Open Access Journals (Sweden)

    Thaïs Florence D. Nogueira

    2013-09-01

    Full Text Available OBJECTIVE To analyze the reasons for non-adherence to follow-up at a specialized outpatient clinic for obese children and adolescents. METHODS Descriptive study of 41 patients, including information from medical records and phone recorded questionnaires which included two open questions and eight closed ones: reason for abandonment, financial and structural difficulties (distance and transport costs, relationship with professionals, obesity evolution, treatment continuity, knowledge of difficulties and obesity complications. RESULTS Among the interviewees, 29.3% reported that adherence to the program spent too much time and it was difficult to adjust consultations to patientsâ€(tm and parentsâ€(tm schedules. Other reasons were: childrenâ€(tms refusal to follow treatment (29.3%, dissatisfaction with the result (17.0%, treatment in another health service (12.2%, difficulty in schedule return (7.3% and delay in attendance (4.9%. All denied any relationship problems with professionals. Among the respondents, 85.4% said they are still overweight. They reported hurdles to appropriate nutrition and physical activity (financial difficulty, lack of parentsâ€(tm time, physical limitation and insecure neighborhood. Among the 33 respondents that reported difficulties with obesity, 78.8% had emotional disorders such as bullying, anxiety and irritability; 24.2% presented fatigue, 15.1% had difficulty in dressing up and 15.1% referred pain. The knowledge of the following complications prevailed: cardicac (97.6%, aesthetic (90.2%, psychological (90.2%, presence of obesity in adulthood (90.2%, diabetes (85.4% and cancer (31.4%. CONCLUSIONS According to the results, it is possible to create weight control public programs that are easier to access, encouraging appropriate nutrition and physical activities in order to achieve obesity prevention.

  20. Polypyrrole-encapsulated vanadium pentoxide nanowires on a conductive substrate for electrode in aqueous rechargeable lithium battery.

    Science.gov (United States)

    Liang, Chaowei; Fang, Dong; Cao, Yunhe; Li, Guangzhong; Luo, Zhiping; Zhou, Qunhua; Xiong, Chuanxi; Xu, Weilin

    2015-02-01

    Precursors of ammonium vanadium bronze (NH4V4O10) nanowires assembled on a conductive substrate were prepared by a hydrothermal method. After calcination at 360°C, the NH4V4O10 precursor transformed to vanadium pentoxide (V2O5) nanowires, which presented a high initial capacity of 135.0mA h g(-1) at a current density of 50mA g(-1) in 5M LiNO3 aqueous solution; while the specific capacity faded quickly over 50 cycles. By coating the surface of V2O5 nanowires with water-insoluble polypyrrole (PPy), the formed nanocomposite electrode exhibited a specific discharge capacity of 89.9mA h g(-1) at 50mA g(-1) (after 100 cycles). A V2O5@PPy //LiMn2O4 rechargeable lithium battery exhibited an initial discharge capacity of 95.2mA h g(-1); and after 100 cycles, a specific discharge capacity of 81.5mA h g(-1) could retain at 100mA g(-1). Copyright © 2014 Elsevier Inc. All rights reserved.