WorldWideScience

Sample records for nocturnal air temperatures

  1. The spatial variability of air temperature and nocturnal urban heat island intensity in the city of Brno, Czech Republic

    Directory of Open Access Journals (Sweden)

    Dobrovolný Petr

    2015-09-01

    Full Text Available This study seeks to quantify the effects of a number of factors on the nocturnal air temperature field in a medium-sized central European city located in complex terrain. The main data sources consist of mobile air temperature measurements and a geographical database. Temperature measurements were taken along several profiles through the city centre and were made under a clear sky with no advection. Altogether nine sets of detailed measurements, in all seasons, were assembled. Altitude, quantity of vegetation, density of buildings and the structure of the transportation (road system were considered as explanatory variables. The result is that the normalized difference vegetation index (NDVI and the density of buildings were the most important factors, each of them explaining a substantial part (more than 50% of overall air temperature variability. Mobile measurements with NDVI values as a covariate were used for interpolation of air temperature for the entire study area. The spatial variability of nocturnal air temperature and UHI intensity in Brno is the main output presented. Air temperatures interpolated from mobile measurements and NDVI values indicate that the mean urban heat island (UHI intensity in the early night in summer is at its highest (approximately 5 °C in the city centre and decreases towards the suburban areas.

  2. The role of sea–land air thermal difference, shape of the coastline and sea surface temperature in the nocturnal offshore convection

    Directory of Open Access Journals (Sweden)

    Jordi Mazón

    2013-01-01

    Full Text Available Nocturnal precipitation cells and lines occur near the coastline in the whole Mediterranean basin in all seasons. The precipitation events are mainly located in areas where coastal mountain ranges and rivers enhance convergence though the interaction of nocturnal mesoscale and local flows (land breeze, katabatic and drainages winds with prevailing synoptic wind or with other mesoscale and local flows. The methodology used here to study this phenomenon consists of three stages. First, the Tropical Rainfall Measuring Mission (TRMM radar satellite database is used to detect nocturnal precipitation near the coastline, from 18 to 09 UTC. An event is included in the study if the 3 hours accumulated precipitation detected by TRMM is stationary near the coast, or has moved slightly onshore or offshore, and has lasted no more than six consecutive hours. Second, the NCEP reanalysis database is used to describe the synoptic conditions and to discard precipitation associated with synoptic events (large low pressure areas, dynamic polar fronts, or troughs, for example. In the final step by using the version 3 of the Weather Research Forecast model, we simulate and analyse some of the selected events to determine the role of the land–sea temperature differences, the curvature of the coastline and the sea surface temperature.The simulations confirm that the nocturnal precipitation studied in the Mediterranean basin near the coastline is formed from the interaction between relatively warm and wet sea-air with the cold air mass from drainage winds, as well as from the convergence of several drainage winds offshore. The mechanism is the same that is used to explain nocturnal precipitation in tropical areas.

  3. Circadian rhythm of temperature selection in a nocturnal lizard.

    Science.gov (United States)

    Refinetti, R; Susalka, S J

    1997-08-01

    We recorded body temperature and locomotor activity of Tokay geckos (Gekko gecko) with free access to a heat source under a 14:10 light-dark cycle and in constant darkness. Under the light-dark cycle, the lizards selected higher temperatures during the light phase, when locomotor activity was less intense. Rhythmicity in temperature selection was transiently disrupted but later resumed when the animals were placed in constant darkness. These results demonstrate the existence of a circadian rhythm of temperature selection in nocturnal ectotherms and extend previous findings of a temporal mismatch between the rhythms of locomotor activity and temperature selection in nocturnal rodents.

  4. Nocturnal drainage wind characteristics in two converging air sheds

    International Nuclear Information System (INIS)

    Gedayloo, T.; Clements, W.E.; Barr, S.; Archuleta, J.A.

    1980-01-01

    During the short experimental period in the Grants Basin of Northeastern New Mexico a survey was conducted on the complex meteorology of this area. Emphasis was placed on the nocturnal drainage flow because of the potential hazards to the populated areas of Milan and Grants from the effluents of the uranium mining and milling operation in this area. This investigation has shown that the nocturnal drainage flow patterns agree with the winds predicted on the basis of the complex terrain of the area. Because of the surface cooling at night (over 25 0 C during summer and about 20 0 C during winter), air from elevated surrounding areas flows to the low lying regions consequently setting up a nocturnal drainage flow. This regime exists over 60% of the time during summer months and over 65% of the time during winter months with a depth generally less than 200 m. In the San Mateo air shed the drainage flow is east northeast, and in the Ambrosia Lake air shed it is from northwest. The confluence of these two air flows contributes mainly to the drainage flow through the channel formed by La Ja Mesa and Mesa Montanosa. The analysis of data collected by the recording Flats Station confirms the prediction that although the area south of the channel region broadens considerably causing a reduction in flow speed, contributions from the southside of La Jara Mesa and Mesa Montanosa partly compensate for this reduction. The position of this recording station is 15 to 20 km from the populated towns of Milan and Grants. A drainage flow speed of approximately 2.2 m s -1 and the duration of over 11 hours as recorded by this station indicates that air from the San Mateo and Ambrosia Lake regions may be transported southwards to these population centers during a nocturnal period. In order to test this prediction, a series of multi-atmospheric tracer experiments were conducted in the Grants Basin

  5. Fiber optic distributed temperature sensing for the determination of the nocturnal atmospheric boundary layer height

    Directory of Open Access Journals (Sweden)

    C. A. Keller

    2011-02-01

    Full Text Available A new method for measuring air temperature profiles in the atmospheric boundary layer at high spatial and temporal resolution is presented. The measurements are based on Raman scattering distributed temperature sensing (DTS with a fiber optic cable attached to a tethered balloon. These data were used to estimate the height of the stable nocturnal boundary layer. The experiment was successfully deployed during a two-day campaign in September 2009, providing evidence that DTS is well suited for this atmospheric application. Observed stable temperature profiles exhibit an exponential shape confirming similarity concepts of the temperature inversion close to the surface. The atmospheric mixing height (MH was estimated to vary between 5 m and 50 m as a result of the nocturnal boundary layer evolution. This value is in good agreement with the MH derived from concurrent Radon-222 (222Rn measurements and in previous studies.

  6. Experimental temperature manipulations alter songbird autumnal nocturnal migratory restlessness

    Directory of Open Access Journals (Sweden)

    Berchtold Adrienne

    2017-02-01

    Full Text Available Migrating birds may respond to a variety of environmental cues in order to time migration. During the migration season nocturnally migrating songbirds may migrate or stop-over at their current location, and when migrating they may vary the rate or distance of migration on any given night. It has long been known that a variety of weather-related factors including wind speed and direction, and temperature, are correlated with migration in free-living birds, however these variables are often correlated with each other. In this study we experimentally manipulated temperature to determine if it would directly modulate nocturnal migratory restlessness in songbirds. We experimentally manipulated temperature between 4, 14, and 24°C and monitored nocturnal migratory restlessness during autumn in white-throated sparrows (Zonotrichia albicollis. White-throated sparrows are relatively shortdistance migrants with a prolonged autumnal migration, and we thus predicted they might be sensitive to weatherrelated cues when deciding whether to migrate or stopover. At warm temperatures (24°C none of the birds exhibited migratory restlessness. The probability of exhibiting migratory restlessness, and the intensity of this restlessness (number of infra-red beam breaks increased at cooler (14°C, 4°C temperatures. These data support the hypothesis that one of the many factors that birds use when making behavioural decisions during migration is temperature, and that birds can respond to temperature directly independently of other weather-related cues.

  7. Performance of a new solar air heater with packed-bed latent storage energy for nocturnal use

    International Nuclear Information System (INIS)

    Bouadila, Salwa; Kooli, Sami; Lazaar, Mariem; Skouri, Safa; Farhat, Abdelhamid

    2013-01-01

    Highlights: • A new solar air heater collector using a phase change material. • Experimental study of the new solar air heater collector with latent storage. • Energy and exergy analysis of the solar heater with latent storage collector. • Nocturnal use of solar air heater collector. - Abstract: An experimental study was conducted to evaluate the thermal performance of a new solar air heater collector using a packed bed of spherical capsules with a latent heat storage system. Using both first and second law of thermodynamics, the energetic and exegetic daily efficiencies were calculated in Closed/Opened and Opened cycle mode. The solar energy was stored in the packed bed through the diurnal period and extracted at night. The experimentally obtained results are used to analyze the performance of the system, based on temperature distribution in different localization of the collectors. The daily energy efficiency varied between 32% and 45%. While the daily exergy efficiency varied between 13% and 25%

  8. Delay in convection in nocturnal boundary layer due to aerosol-induced cooling

    Science.gov (United States)

    Singh, Dhiraj Kumar; Ponnulakshmi, V. K.; Subramanian, G.; Sreenivas, K. R.

    2012-11-01

    Heat transfer processes in the nocturnal boundary layer (NBL) influence the surface energy budget, and play an important role in many micro-meteorological processes including the formation of inversion layers, radiation fog, and in the control of air-quality near the ground. Under calm clear-sky conditions, radiation dominates over other transport processes, and as a result, the air layers just above ground cool the fastest after sunset. This leads to an anomalous post-sunset temperature profile characterized by a minimum a few decimeters above ground (Lifted temperature minimum). We have designed a laboratory experimental setup to simulate LTM, involving an enclosed layer of ambient air, and wherein the boundary condition for radiation is decoupled from those for conduction and convection. The results from experiments involving both ambient and filtered air indicate that the high cooling rates observed are due to the presence of aerosols. Calculated Rayleigh number of LTM-type profiles is of the order 105-107 in the field and of order 103-105 in the laboratory. In the LTM region, there is convective motion when the Rayleigh number is greater than 104 rather than the critical Rayleigh number (Rac = 1709). The diameter of convection rolls is a function of height of minimum of LTM-type profiles. The results obtained should help in the parameterization of transport process in the nocturnal boundary layer, and highlight the need to accounting the effects of aerosols and ground emissivity in climate models.

  9. A case study of the development of nocturnal slope flows in a wide open valley and associated air quality implications

    Energy Technology Data Exchange (ETDEWEB)

    Pardyjak, Eric R. [Utah Univ., Salt Lake City, UT (United States). Dept. of Mechanical Engineering; Fernando, Harindra Joseph S.; Anderson, James [Arizona State Univ., Tempe, AZ (United States). Center for Environmental Fluid Dynamics; Hunt, Julian C.R. [University Coll., London (United Kingdom). Dept. of Space and Climate Physics, and Earth Sciences; Grachev, Andrey A. [Colorado Univ./NOAA, Boulder, CO (US). Cooperative Inst. for Research in Environmental Sciences (CIRES)

    2009-07-01

    This paper documents the development of nocturnal flows in the wide open Phoenix, Arizona (U.S.A) valley (30 km x 100 km) that is bordered by a large nearly flat plain to the west and high mountains to the north and east. Local thermally driven winds concomitant with the absence of significant synoptic pressure gradients dominate typical winter conditions in the Phoenix valley. The purpose of the Phoenix Air Flow Experiment (PAFEX-1) was to study the development of thermally driven flows during the evening transition in a sloping valley and describe the general pattern of transport and dispersion of contaminants during transition periods and at night. Measurements were made using a tethered balloon, sonic anemometer, balloon-based aerosol sampler, radiation sensors, cup anemometers, thermistors and humidity sensors in conjunction with data collected from 44 standard meteorological stations located throughout the valley. Over the period of 15 days in January and February 1998 the general diurnal flow patterns were repeatable, but varied substantially around the valley. This paper focuses on a case study of the evening transition, nocturnal circulation and morning breakdown of the nocturnal circulation on the night of 31 January and morning of 1 February. Central valley measurements were consistent with the notion that the evening transition is associated with a moving front, followed by intense mixing and the movement of the front to establish down-valley winds. Flows originating from different slopes led to the arrival of fronts at the various measurement locations at different times. These flows intrude into the valley and interact with each other, often causing multi-layered vertical structure. The intrusions respond to the evolving stratification and cause striking variability of these layers, for example, periodic wind and temperature disturbances corresponding to the arrival of new intrusive fronts. The evolution of the boundary layer was found to have a

  10. Nocturnal infrared clear sky temperatures correlated with screen temperatures and GPS-derived PWV in southern Australia

    International Nuclear Information System (INIS)

    Maghrabi, A.; Clay, R.

    2011-01-01

    Highlights: → Model to calculate nocturnal sky temperature in mid-latitude site was developed. → New data acquired from new instrument. → Sky temperature correlated with both GPS-derived PWV and screen temperature. → The model was tested theoretically against MODTRAN software. → The performance of the model was compared against 20 independent models. - Abstract: Infrared (IR) clear sky temperatures (Tsky), screen level temperature (T) and Precipitable Water Vapour (PWV) were collected for a period of 2 years from a coastal region of southern Australia. IR sky temperatures were derived from simple infrared detectors, which have been developed by the authors for inexpensive monitoring of cloud cover, while data for PWV were obtained from Global Positioning Satellite (GPS) transmissions. Meteorological data were obtained from the Australian Bureau of Meteorology. Based on these data, statistical regression analyses between nocturnal Tsky and the T and PWV (one variable fit) were conducted. Direct proportional relationships between Tsky and T and between Tsky and PWV were found. The one variable fit was further optimized by applying the multiple regression fit between Tsky and both T and PWV. The resulting multilinear model was essentially unbiased, with a correlation coefficient (R 2 ) of 0.97, mean bias error (MBE) of -2.7 x 10 -5 deg. C, and root mean square error (RMSE) of about 1.6 o C. The performance of the multilinear model was tested against a 1-year independent data set. In this case, the predictability of the model was superior, with MBE and RMSE being 0.13 deg. C and 2.23 deg. C respectively. After correcting the daytime observations for the biases caused by solar heating of the detection system, the performance of this model in calculating the daytime measurements was tested and showed MBE and RMSE values of 1.3 deg. C and 2.5 deg. C, respectively. Additionally, twenty schemes from the literature were tested and assessed for predicting the

  11. Effects of open-air temperature on air temperature inside biological safety cabinet.

    Science.gov (United States)

    Umemura, Masayuki; Shigeno, Katsuro; Yamamura, Keiko; Osada, Takashi; Soda, Midori; Yamada, Kiyofumi; Ando, Yuichi; Wakiya, Yoshifumi

    2011-02-14

    In Japan, biological safety cabinets (BSCs) are normally used by medical staff while handling antineoplastic agents. We have also set up a class II B2 BSC at the Division of Chemotherapy for Outpatients. The air temperature inside this BSC, however, decreases in winter. We assumed that this decrease is caused by the intake of open-air. Therefore, we investigated the effects of low open-air temperature on the BSC temperature and the time of admixtures of antineoplastic agents. The studies were conducted from January 1 to March 31, 2008. The outdoor air temperature was measured in the shade near the intake nozzle of the BSC and was compared with the BSC temperature. The correlation between the outdoor air temperature and the BSC temperature, the dissolution time of cyclophosphamide (CPA) and gemcitabine (GEM), and accurate weight measurement of epirubicin (EPI) solution were investigated for low and normal BSC temperatures. The BSC temperature was correlated with the open-air temperature for open-air temperatures of 5-20°C (p air is drawn from outdoors. We showed that the BSC temperature affects the dissolution rate of antineoplastic agents. Further, we suggested that the BSC temperature drop might delay the affair of the admixtures of antineoplastic agents and increase the waiting time of outpatients for chemotherapy.

  12. Effect of indomethacin on desmopressin resistant nocturnal polyuria and nocturnal enuresis.

    Science.gov (United States)

    Kamperis, Konstantinos; Rittig, Søren; Bower, Wendy F; Djurhuus, Jens C

    2012-11-01

    We evaluated the acute effect of indomethacin on renal water and solute handling in children with coexisting monosymptomatic nocturnal enuresis and desmopressin resistant nocturnal polyuria, and in healthy controls. A total of 23 subjects were recruited, consisting of 12 children with monosymptomatic nocturnal enuresis and nocturnal polyuria with partial or no response to desmopressin, and 11 age matched controls. Children completed a 48-hour inpatient study protocol consisting of fractional urine collections and blood samples. Sodium and water intake were standardized. During the second night a dose of 50 mg indomethacin was administered orally before bedtime. Diuresis, urine osmolalities, clearances and fractional excretions were calculated for sodium, potassium, urea, osmoles and solute-free water. Renin, angiotensin II, aldosterone and atrial natriuretic peptide were measured in plasma. Prostaglandin E(2) was measured in urine. Indomethacin markedly decreased the nocturnal sodium, urea and osmotic excretion in children with enuresis and controls. The overall effect on nocturnal urine output was inconsistent in the group with enuresis. Subjects in whom nocturnal diuresis was decreased following administration of indomethacin remained dry. Prostaglandin inhibition leads to antidiuresis, reducing the amount of sodium, urea and osmotic excretion in children with monosymptomatic nocturnal enuresis and desmopressin resistant nocturnal polyuria. The sodium regulating hormones do not seem to mediate these processes. The overall effect in desmopressin nonresponders with nocturnal polyuria is variable. The extent to which indomethacin can be applied in the treatment of enuresis needs further evaluation. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. On the importance of radiative heat exchange during nocturnal flight in birds.

    Science.gov (United States)

    Léger, Jérôme; Larochelle, Jacques

    2006-01-01

    Many migratory flights take place during cloudless nights, thus under conditions where the sky temperature can commonly be 20 degrees C below local air temperature. The sky then acts as a radiative sink, leading objects exposed to it to have a lower surface temperature than unexposed ones because less infrared energy is received from the sky than from the surfaces that are isothermic to air. To investigate the significance of this effect for heat dissipation during nocturnal flight in birds, we built a wind tunnel with the facility to control wall temperature (TASK) and air temperature (TAIR) independently at air speeds (UWIN) comparable to flying speeds. We used it to measure the influence of TASK, TAIR and UWIN on plumage and skin temperatures in pigeons having to dissipate a thermal load while constrained at rest in a flight posture. Our results show that the temperature of the flight and insulation plumages exposed to a radiative sink can be accurately described by multiple regression models (r2>0.96) based only on TAIR, TASK and UWIN. Predictions based on these models indicate that while convection dominates heat loss for a plumage exposed to air moving at flight speed in a thermally uniform environment, radiation may dominate in the presence of a radiative sink comparable to a clear sky. Our data also indicate that reducing TASK to a temperature 20 degrees C below TAIR can increase the temperature difference across the exposed plumage by at least 13% and thus facilitate heat flow through the main thermal resistance to the loss of internally produced heat in birds. While extrapolation from our experimentally constrained conditions to free flight in the atmosphere is difficult, our results suggest that the sky temperature has been a neglected factor in determining the range of TAIR over which prolonged flight is possible.

  14. Scale Modelling of Nocturnal Cooling in Urban Parks

    Science.gov (United States)

    Spronken-Smith, R. A.; Oke, T. R.

    Scale modelling is used to determine the relative contribution of heat transfer processes to the nocturnal cooling of urban parks and the characteristic temporal and spatial variation of surface temperature. Validation is achieved using a hardware model-to-numerical model-to-field observation chain of comparisons. For the calm case, modelling shows that urban-park differences of sky view factor (s) and thermal admittance () are the relevant properties governing the park cool island (PCI) effect. Reduction in sky view factor by buildings and trees decreases the drain of longwave radiation from the surface to the sky. Thus park areas near the perimeter where there may be a line of buildings or trees, or even sites within a park containing tree clumps or individual trees, generally cool less than open areas. The edge effect applies within distances of about 2.2 to 3.5 times the height of the border obstruction, i.e., to have any part of the park cooling at the maximum rate a square park must be at least twice these dimensions in width. Although the central areas of parks larger than this will experience greater cooling they will accumulate a larger volume of cold air that may make it possible for them to initiate a thermal circulation and extend the influence of the park into the surrounding city. Given real world values of s and it seems likely that radiation and conduction play almost equal roles in nocturnal PCI development. Evaporation is not a significant cooling mechanism in the nocturnal calm case but by day it is probably critical in establishing a PCI by sunset. It is likely that conditions that favour PCI by day (tree shade, soil wetness) retard PCI growth at night. The present work, which only deals with PCI growth, cannot predict which type of park will be coolest at night. Complete specification of nocturnal PCI magnitude requires knowledge of the PCI at sunset, and this depends on daytime energetics.

  15. Crowdsourcing urban air temperatures from smartphone battery temperatures

    Science.gov (United States)

    Overeem, Aart; Robinson, James C. R.; Leijnse, Hidde; Steeneveld, Gert-Jan; Horn, Berthold K. P.; Uijlenhoet, Remko

    2014-05-01

    Accurate air temperature observations in urban areas are important for meteorology and energy demand planning. They are indispensable to study the urban heat island effect and the adverse effects of high temperatures on human health. However, the availability of temperature observations in cities is often limited. Here we show that relatively accurate air temperature information for the urban canopy layer can be obtained from an alternative, nowadays omnipresent source: smartphones. In this study, battery temperatures were collected by an Android application for smartphones. It has been shown that a straightforward heat transfer model can be employed to estimate daily mean air temperatures from smartphone battery temperatures for eight major cities around the world. The results demonstrate the enormous potential of this crowdsourcing application for real-time temperature monitoring in densely populated areas. Battery temperature data were collected by users of an Android application for cell phones (opensignal.com). The application automatically sends battery temperature data to a server for storage. In this study, battery temperatures are averaged in space and time to obtain daily averaged battery temperatures for each city separately. A regression model, which can be related to a physical model, is employed to retrieve daily air temperatures from battery temperatures. The model is calibrated with observed air temperatures from a meteorological station of an airport located in or near the city. Time series of air temperatures are obtained for each city for a period of several months, where 50% of the data is for independent verification. The methodology has been applied to Buenos Aires, London, Los Angeles, Paris, Mexico City, Moscow, Rome, and Sao Paulo. The evolution of the retrieved air temperatures often correspond well with the observed ones. The mean absolute error of daily air temperatures is less than 2 degrees Celsius, and the bias is within 1 degree

  16. Radiation forcing by the atmospheric aerosols in the nocturnal boundary layer

    Science.gov (United States)

    Singh, D. K.; Ponnulakshami, V. K.; Mukund, V.; Subramanian, G.; Sreenivas, K. R.

    2013-05-01

    We have conducted experimental and theoretical studies on the radiation forcing due to suspended aerosols in the nocturnal boundary layer. We present radiative, conductive and convective equilibrium profile for different bottom boundaries where calculated Rayleigh number is higher than the critical Rayleigh number in laboratory conditions. The temperature profile can be fitted using an exponential distribution of aerosols concentration field. We also present the vertical temperature profiles in a nocturnal boundary in the presence of fog in the field. Our results show that during the presence of fog in the atmosphere, the ground temperature is greater than the dew-point temperature. The temperature profiles before and after the formation of fog are also observed to be different.

  17. An Improved Iterative Fitting Method to Estimate Nocturnal Residual Layer Height

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-08-01

    Full Text Available The planetary boundary layer (PBL is an atmospheric region near the Earth’s surface. It is significant for weather forecasting and for the study of air quality and climate. In this study, the top of nocturnal residual layers—which are what remain of the daytime mixing layer—are estimated by an elastic backscatter Lidar in Wuhan (30.5°N, 114.4°E, a city in Central China. The ideal profile fitting method is widely applied to determine the nocturnal residual layer height (RLH from Lidar data. However, the method is seriously affected by an optical thick layer. Thus, we propose an improved iterative fitting method to eliminate the optical thick layer effect on RLH detection using Lidar. Two typical case studies observed by elastic Lidar are presented to demonstrate the theory and advantage of the proposed method. Results of case analysis indicate that the improved method is more practical and precise than profile-fitting, gradient, and wavelet covariance transform method in terms of nocturnal RLH evaluation under low cloud conditions. Long-term observations of RLH performed with ideal profile fitting and improved methods were carried out in Wuhan from 28 May 2011 to 17 June 2016. Comparisons of Lidar-derived RLHs with the two types of methods verify that the improved solution is practical. Statistical analysis of a six-year Lidar signal was conducted to reveal the monthly average values of nocturnal RLH in Wuhan. A clear RLH monthly cycle with a maximum mean height of about 1.8 km above ground level was observed in August, and a minimum height of about 0.7 km was observed in January. The variation in monthly mean RLH displays an obvious quarterly dependence, which coincides with the annual variation in local surface temperature.

  18. Light pollution modifies the expression of daily rhythms and behavior patterns in a nocturnal primate.

    Directory of Open Access Journals (Sweden)

    Thomas Le Tallec

    Full Text Available Among anthropogenic pressures, light pollution altering light/dark cycles and changing the nocturnal component of the environment constitutes a threat for biodiversity. Light pollution is widely spread across the world and continuously growing. However, despite the efforts realized to describe and understand the effects of artificial lighting on fauna, few studies have documented its consequences on biological rhythms, behavioral and physiological functions in nocturnal mammals. To determine the impacts of light pollution on nocturnal mammals an experimental study was conducted on a nocturnal primate, the grey mouse lemur Microcebus murinus. Male mouse lemurs (N = 8 were exposed 14 nights to moonlight treatment and then exposed 14 nights to light pollution treatment. For both treatments, chronobiological parameters related to locomotor activity and core temperature were recorded using telemetric transmitters. In addition, at the end of each treatment, the 14(th night, nocturnal and feeding behaviors were explored using an infrared camera. Finally, throughout the study, body mass and daily caloric food intake were recorded. For the first time in a nocturnal primate, light pollution was demonstrated to modify daily rhythms of locomotor activity and core temperature especially through phase delays and increases in core temperature. Moreover, nocturnal activity and feeding behaviors patterns were modified negatively. This study suggests that light pollution induces daily desynchronization of biological rhythms and could lead to seasonal desynchronization with potential deleterious consequences for animals in terms of adaptation and anticipation of environmental changes.

  19. Light pollution modifies the expression of daily rhythms and behavior patterns in a nocturnal primate.

    Science.gov (United States)

    Le Tallec, Thomas; Perret, Martine; Théry, Marc

    2013-01-01

    Among anthropogenic pressures, light pollution altering light/dark cycles and changing the nocturnal component of the environment constitutes a threat for biodiversity. Light pollution is widely spread across the world and continuously growing. However, despite the efforts realized to describe and understand the effects of artificial lighting on fauna, few studies have documented its consequences on biological rhythms, behavioral and physiological functions in nocturnal mammals. To determine the impacts of light pollution on nocturnal mammals an experimental study was conducted on a nocturnal primate, the grey mouse lemur Microcebus murinus. Male mouse lemurs (N = 8) were exposed 14 nights to moonlight treatment and then exposed 14 nights to light pollution treatment. For both treatments, chronobiological parameters related to locomotor activity and core temperature were recorded using telemetric transmitters. In addition, at the end of each treatment, the 14(th) night, nocturnal and feeding behaviors were explored using an infrared camera. Finally, throughout the study, body mass and daily caloric food intake were recorded. For the first time in a nocturnal primate, light pollution was demonstrated to modify daily rhythms of locomotor activity and core temperature especially through phase delays and increases in core temperature. Moreover, nocturnal activity and feeding behaviors patterns were modified negatively. This study suggests that light pollution induces daily desynchronization of biological rhythms and could lead to seasonal desynchronization with potential deleterious consequences for animals in terms of adaptation and anticipation of environmental changes.

  20. Global effects of moon phase on nocturnal acoustic scattering layers

    KAUST Repository

    Prihartato, Perdana; Irigoien, Xabier; Genton, Marc G.; Kaartvedt, Stein

    2016-01-01

    © Inter-Research 2016. The impact of moon phase on the global nocturnal vertical distribution of acoustic scattering layers (SLs) in the upper 200 m was studied during the Malaspina expedition that circumnavigated the world. We assessed the nocturnal weighted mean depths and the vertical extension of the SL (the range between the upper 25th percentile and lower 75th percentile of the backscatter) and used a generalized additive model to reveal the relationship between the nocturnal vertical distribution of the SL and moon phase, as well as other environmental factors. Moon phase significantly affected the SL distribution on a global scale, in contrast to other factors such as dissolved oxygen, temperature and fluorescence, which each correlated with nocturnal SL distribution during the large geographic coverage. Full moon caused a deepening effect on the nocturnal SL. Contrary to expectations, the shallowest distribution was not observed during the darkest nights (new moon) and there was no difference in vertical distribution between new moon and intermediate moon phases. We conclude that the trend of deepening SL during approximately full moon (bright nights) is a global phenomenon related to anti-predator behavior.

  1. Global effects of moon phase on nocturnal acoustic scattering layers

    KAUST Repository

    Prihartato, PK

    2016-01-18

    © Inter-Research 2016. The impact of moon phase on the global nocturnal vertical distribution of acoustic scattering layers (SLs) in the upper 200 m was studied during the Malaspina expedition that circumnavigated the world. We assessed the nocturnal weighted mean depths and the vertical extension of the SL (the range between the upper 25th percentile and lower 75th percentile of the backscatter) and used a generalized additive model to reveal the relationship between the nocturnal vertical distribution of the SL and moon phase, as well as other environmental factors. Moon phase significantly affected the SL distribution on a global scale, in contrast to other factors such as dissolved oxygen, temperature and fluorescence, which each correlated with nocturnal SL distribution during the large geographic coverage. Full moon caused a deepening effect on the nocturnal SL. Contrary to expectations, the shallowest distribution was not observed during the darkest nights (new moon) and there was no difference in vertical distribution between new moon and intermediate moon phases. We conclude that the trend of deepening SL during approximately full moon (bright nights) is a global phenomenon related to anti-predator behavior.

  2. A stable boundary layer perspective on global temperature trends

    International Nuclear Information System (INIS)

    McNider, R T; Christy, J R; Biazar, A

    2010-01-01

    One of the most significant signals in the thermometer-observed temperature record since 1900 is the decrease in the diurnal temperature range over land, largely due to warming of the minimum temperatures. While some data sets have indicated this asymmetrical warming has been reduced since 1979, regional analyses (e.g. East Africa) indicate that the nocturnal warming continues at a pace greater than daytime temperatures. The cause for this night time warming in the observed temperatures has been attributed to a variety of causes. Climate models have in general not replicated the change in diurnal temperature range well. Here we would like to try to distinguish between warming in the nocturnal boundary layer due to a redistribution of heat and warming due to the accumulation of heat. The temperature at night at shelter height is a result of competition between thermal stability and mechanical shear. If stability wins then turbulence is suppressed and the cooling surface becomes cut-off from the warmer air aloft, which leads to sharp decay in surface air temperature. If shear wins, then turbulence is maintained and warmer air from aloft is continually mixed to the surface, which leads to significantly lower cooling rates and warmer temperatures. This warming occurs due to a redistribution of heat. As will be shown by techniques of nonlinear analysis the winner of the stability and shear contest can be very sensitive to changes in greenhouse gas forcing, surface roughness, cloudiness, and surface heat capacity (including soil moisture). Further, the minimum temperatures measured in the nocturnal boundary layer represent only a very shallow layer of the atmosphere which is usually only a few hundred meters thick. It is likely that the observed warming in minimum temperature, whether caused by additional greenhouse forcing or land use changes or other land surface dynamics, is reflecting a redistribution of heat by turbulence-not an accumulation of heat. Because minimum

  3. Perceived air quality, thermal comfort, and SBS symptoms at low air temperature and increased radiant temperature

    DEFF Research Database (Denmark)

    Toftum, Jørn; Reimann, Gregers Peter; Foldbjerg, P.

    2002-01-01

    source present at the low temperature. To maintain overall thermal neutrality, the low air temperature was partly compensated for by individually controlled radiant heating, and partly by allowing subjects to modify clothing insulation. A reduction of the air temperature from 23 deg.C to 18 deg.......C suggested an improvement of the perceived air quality, while no systematic effect on symptom intensity was observed. The overall indoor environment was evaluated equally acceptable at both temperatures due to local thermal discomfort at the low air temperature....

  4. Effects of a Heat Wave on Nocturnal Stomatal Conductance in Eucalyptus camaldulensis

    Directory of Open Access Journals (Sweden)

    Víctor Resco de Dios

    2018-06-01

    Full Text Available Nocturnal transpiration constitutes a significant yet poorly understood component of the global water cycle. Modeling nocturnal transpiration has been complicated by recent findings showing that stomata respond differently to environmental drivers over day- vs. night-time periods. Here, we propose that nocturnal stomatal conductance depends on antecedent daytime conditions. We tested this hypothesis across six genotypes of Eucalyptus camaldulensis Dehnh. growing under different CO2 concentrations (ambient vs. elevated and exposed to contrasting temperatures (ambient vs. heat wave for four days prior to the night of measurements, when all plants experienced ambient temperature conditions. We observed significant effects after the heat wave that led to 36% reductions in nocturnal stomatal conductance. The response was partly driven by changes in daytime stomatal behavior but additional factors may have come into play. We also observed significant differences in response to the heat wave across genotypes, likely driven by local adaptation to their climate of origin, but CO2 played no effect. Stomatal models may need to incorporate the role of antecedent effects to improve projections particularly after drastic changes in the environment such as heat waves.

  5. Current management of nocturnal enuresis.

    Science.gov (United States)

    Robson, Wm Lane M

    2008-07-01

    Nocturnal enuresis is an especially common problem with the potential to have an appreciable negative impact on the emotional health of a child. Our understanding of the pathogenesis continues to improve. A disorder of sleep arousal, a low nocturnal bladder capacity, and nocturnal polyuria are the three factors that interrelate to cause nocturnal enuresis. Constipation is a very common and often unrecognized factor that appreciably affects bladder function. Successful treatment involves interventions that simultaneously improve these factors. Self-esteem improves with any form of therapy and dryness is possible for the majority of children.

  6. The effect of air velocity on heat stress at increased air temperature

    DEFF Research Database (Denmark)

    Bjerg, B.; Wang, Xiaoshuai; Zhang, Guoqiang

    Increased air velocity is a frequently used method to reduce heat stress of farm animals housed in warm conditions. The main reason why the method works is that higher air velocity increases the convective heat release from the animals. Convective heat release from the animals is strongly related...... to the temperature difference between the surfaces of animals and the surrounding air, and this temperature difference declines when the air temperature approaches the animal body temperature. Consequently it can it by expected that the effect of air velocity decreases at increased air temperature. The literature...... on farm animals in warm conditions includes several thermal indices which incorporate the effect of air velocities. But, surprisingly none of them predicts a decreased influence of air velocity when the air temperature approaches the animal body temperature. This study reviewed published investigations...

  7. Nocturnal continuous glucose monitoring

    DEFF Research Database (Denmark)

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik

    2013-01-01

    Abstract Background: A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe...

  8. Methane distributions and transports in the nocturnal boundary layer at a rural station

    Science.gov (United States)

    Schäfer, Klaus; Zeeman, Matthias; Brosy, Caroline; Münkel, Christoph; Fersch, Benjamin; Mauder, Matthias; Emeis, Stefan

    2016-10-01

    To investigate the methane distributions and transports, the role of related atmospheric processes by determination of vertical profiles of wind, turbulence, temperature and humidity as well as nocturnal boundary layer (NBL) height and the quantification of methane emissions at local and plot scale the so-called ScaleX-campaign was performed in a pre-alpine observatory in Southern Germany from 01 June until 31 July 2015. The following measurements from the ground up to the free troposphere were performed: layering of the atmosphere by a ceilometer (Vaisala CL51); temperature, wind, turbulence profiles from 50 m up to 500 m by a Radio-Acoustic Sounding System (RASS, Metek GmbH); temperature, humidity profiles in situ by a hexacopter; methane farm emissions by two open-path laser spectrometers (Boreal GasFinder2); methane concentrations in situ (Los Gatos DLT-100) with tubes in 0.3 m agl and 5 sampling heads; and methane soil emissions by a big chamber (10 m length, 2.60 m width, up to 0.61 m height) with a plastic cover. The methane concentrations near the surface show a daily variation with a maximum and a frequent double-peak structure during night-time. Analysis of the variation of the nocturnal methane concentration together with the hexacopter and RASS data indicates that the first peak in the nocturnal methane concentration is probably due to local cooling and stabilization which keeps the methane emissions from the soil near the ground. The second peak seems to be due to advection of methane-enriched air which had formed in the environment of the nearby farm yards. These dairy farm emissions were determined by up-wind and down-wind open-path concentration measurements, turbulence data from an EC station nearby and Backward Lagrangian Simulation (WindTrax software). The methane fluxes at plot scale (big chamber) are characterized by emissions at water saturated grassland patches, by an exponential decrease of these emissions during grassland drying, and by an

  9. Retrieval of air temperatures from crowd-sourced battery temperatures of cell phones

    Science.gov (United States)

    Overeem, Aart; Robinson, James; Leijnse, Hidde; Uijlenhoet, Remko; Steeneveld, Gert-Jan; Horn, Berthold K. P.

    2013-04-01

    Accurate air temperature observations are important for urban meteorology, for example to study the urban heat island and adverse effects of high temperatures on human health. The number of available temperature observations is often relatively limited. A new development is presented to derive temperature information for the urban canopy from an alternative source: cell phones. Battery temperature data were collected by users of an Android application for cell phones (opensignal.com). The application automatically sends battery temperature data to a server for storage. In this study, battery temperatures are averaged in space and time to obtain daily averaged battery temperatures for each city separately. A regression model, which can be related to a physical model, is employed to retrieve daily air temperatures from battery temperatures. The model is calibrated with observed air temperatures from a meteorological station of an airport located in or near the city. Time series of air temperatures are obtained for each city for a period of several months, where 50% of the data is for independent verification. Results are presented for Buenos Aires, London, Los Angeles, Paris, Mexico City, Moscow, Rome, and Sao Paulo. The evolution of the retrieved air temperatures often correspond well with the observed ones. The mean absolute error of daily air temperatures is less than 2 degrees Celsius, and the bias is within 1 degree Celsius. This shows that monitoring air temperatures employing an Android application holds great promise. Since 75% of the world's population has a cell phone, 20% of the land surface of the earth has cellular telephone coverage, and 500 million devices use the Android operating system, there is a huge potential for measuring air temperatures employing cell phones. This could eventually lead to real-time world-wide temperature maps.

  10. Experiments on aerosol-induced cooling in the nocturnal boundary layer

    Science.gov (United States)

    Sreenivas, K.; Singh, D. K.; Vk, P.; Mukund, V.; Subramanian, G.

    2012-12-01

    In the nocturnal boundary layer (NBL), under calm & clear-sky conditions, radiation is the principal mode of heat transfer & it determines the temperature distribution close to the ground. Radiative processes thus influence the surface energy budget, & play a decisive role in many micro-meteorological processes including the formation of radiation-fog & inversion layer. Here, we report hyper-cooling of air layers close to the ground that has a radiative origin. Resulting vertical temperature distribution has an anomalous profile with an elevated minimum few decimetres above the ground (known as Lifted Temperature Minimum; LTM). Even though the first observation of this type of profile dates back to 1930s, its origin has not been explained till recently. We report field experiments to elucidate effects of emissivity and other physical properties of the ground on the LTM profile. Field observations clearly indicate that LTM-profiles are observed as a rule in the lowest meter of the NBL. We also demonstrate that the air-layer near the ground, rather than the ground itself, leads the post sunset cooling. This fact changes the very nature of the sensible heat-flux boundary condition. A laboratory experimental setup has been developed that can reproduce LTM. Lab-experiments demonstrate that the high cooling rates observed in the field experiments arise from the presence of aerosols & the intensity of cooling is proportional to aerosol concentration (Fig-1). We have also captured penetrative convection cells in the field experiments (Fig-2). Results presented here thus help in parameterizing transport processes in the NBL.

  11. Summertime nocturnal drainage flow in the San Mateo and Ambrosia lake air sheds of the grants basin

    International Nuclear Information System (INIS)

    Gedayloo, T.; Barr, S.; Clements, W.E.; Wilson, S.K.

    1979-01-01

    An initial study of some fundamental meteorological properties of two major air sheds in the Grants Basin of northwestern New Mexico was conducted from May 18 to September 19, 1978. Three mechanical weather stations were used in conjunction with a few vertical wind soundings to develop a data set for the summer regime. Data collected between May 18 and July 30 is analyzed to investigate nocturnal drainage flows, daytime flows, and channeling of synoptic wind. Drainage wind averaging 2.5 m s -1 was found to exist in a surface layer not greater than 200 m deep on 60% of the nights investigated. This frequently occurring drainage flow is characterized by a strong decoupling from the upper level winds. Daytime winds, on the other hand, are representative of the synoptic flow patterns suggesting a rather rapid coupling after sunrise

  12. Comparative Effects of an Angiotensin II Receptor Blocker (ARB)/Diuretic vs. ARB/Calcium-Channel Blocker Combination on Uncontrolled Nocturnal Hypertension Evaluated by Information and Communication Technology-Based Nocturnal Home Blood Pressure Monitoring - The NOCTURNE Study.

    Science.gov (United States)

    Kario, Kazuomi; Tomitani, Naoko; Kanegae, Hiroshi; Ishii, Hajime; Uchiyama, Kazuaki; Yamagiwa, Kayo; Shiraiwa, Toshihiko; Katsuya, Tomohiro; Yoshida, Tetsuro; Kanda, Kiyomi; Hasegawa, Shinji; Hoshide, Satoshi

    2017-06-23

    Nocturnal blood pressure (BP) is an independent risk factor of cardiovascular events. The NOCTURNE study, a multicenter, randomized controlled trial (RCT) using our recently developed information and communication technology (ICT) nocturnal home BP monitoring (HBPM) device, was performed to compare the nocturnal HBP-lowering effects of differential ARB-based combination therapies in 411 Japanese patients with nocturnal hypertension (HT).Methods and Results:Patients with nocturnal BP ≥120/70 mmHg at baseline even under ARB therapy (100 mg irbesartan daily) were enrolled. The ARB/CCB combination therapy (irbesartan 100 mg+amlodipine 5 mg) achieved a significantly greater reduction in nocturnal home systolic BP (primary endpoint) than the ARB/diuretic combination (daily irbesartan 100 mg+trichlormethiazide 1 mg) (-14.4 vs. -10.5 mmHg, P<0.0001), independently of urinary sodium excretion and/or nocturnal BP dipping status. However, the change in nocturnal home systolic BP was comparable among the post-hoc subgroups with higher salt sensitivity (diabetes, chronic kidney disease, and elderly patients). This is the first RCT demonstrating the feasibility of clinical assessment of nocturnal BP by ICT-nocturnal HBPM. The ARB/CCB combination was shown to be superior to ARB/diuretic in patients with uncontrolled nocturnal HT independently of sodium intake, despite the similar impact of the 2 combinations in patients with higher salt sensitivity.

  13. Nocturnal Polyuria: Excess of Nocturnal Urine Production, Excess of Definitions-Influence on Renal Function Profile.

    Science.gov (United States)

    Goessaert, An-Sofie; Walle, Johan Vande; Bosch, Ruud; Hoebeke, Piet; Everaert, Karel

    2016-03-01

    This study aimed to identify important differences in renal function profile, and potential water and sodium diuresis cutoffs among participants with nocturnal polyuria according to nocturnal polyuria definitions. This post hoc analysis was based on a prospective study in which participants completed a bladder diary, collected urine and provided a blood sample. With an age dependent nocturnal polyuria index greater than 20% to 33% as the referent 4 definitions of nocturnal polyuria were compared, including 1) nocturnal polyuria index greater than 33%, 2) nocturnal urine production greater than 90 ml per hour and 3) greater than 10 ml/kg, and 4) nocturia index greater than 1.5. In 112 male and female participants significant differences in baseline characteristics and bladder diary parameters were found according to definition. Diuresis rate, free water clearance and sodium clearance had similar 24-hour courses in the subgroups with and without polyuria by each definition. The range varied more in the subgroup with vs without polyuria, especially at night for diuresis rate and free water clearance. At night the latter decreased in the polyuria subgroup based on each definition (p polyuria subgroups was found only for urine production greater than 90 ml per hour and polyuria index greater than 20% to 33%. For each definition sodium clearance remained high in the polyuria subgroup, which differed significantly from the no polyuria subgroups (p polyuria by definition. The renal function profile indicating the pathophysiological mechanism of nocturnal polyuria did not seem to be influenced by definition but free water clearance and sodium clearance cutoff sensitivity differed substantially. These results must be confirmed in a larger homogeneous sample. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Effects of air temperature and discharge on Upper Mississippi River summer water temperatures

    Science.gov (United States)

    Gray, Brian R.; Robertson, Dale M.; Rogala, James T.

    2018-01-01

    Recent interest in the potential effects of climate change has prompted studies of air temperature and precipitation associations with water temperatures in rivers and streams. We examined associations between summer surface water temperatures and both air temperature and discharge for 5 reaches of the Upper Mississippi River during 1994–2011. Water–air temperature associations at a given reach approximated 1:1 when estimated under an assumption of reach independence but declined to approximately 1:2 when water temperatures were permitted to covary among reaches and were also adjusted for upstream air temperatures. Estimated water temperature–discharge associations were weak. An apparently novel feature of this study is that of addressing changes in associations between water and air temperatures when both are correlated among reaches.

  15. Remotely-sensed, nocturnal, dew point correlates with malaria transmission in Southern Province, Zambia: a time-series study.

    Science.gov (United States)

    Nygren, David; Stoyanov, Cristina; Lewold, Clemens; Månsson, Fredrik; Miller, John; Kamanga, Aniset; Shiff, Clive J

    2014-06-13

    Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor results at the zonal level. In this

  16. Nocturnal Polyuria : Excess of Nocturnal Urine Production, Excess of Definitions-Influence on Renal Function Profile

    NARCIS (Netherlands)

    Goessaert, An-Sofie; Walle, Johan Vande; Bosch, JLHR; Hoebeke, Piet; Everaert, Karel

    2016-01-01

    PURPOSE: This study aimed to identify important differences in renal function profile, and potential water and sodium diuresis cutoffs among participants with nocturnal polyuria according to nocturnal polyuria definitions. MATERIALS AND METHODS: This post hoc analysis was based on a prospective

  17. Hyper-cooling in the nocturnal boundary layer: the Ramdas paradox

    International Nuclear Information System (INIS)

    Mukund, V; Ponnulakshmi, V K; Singh, D K; Subramanian, G; Sreenivas, K R

    2010-01-01

    Characterizing the interaction between turbulence and radiative processes is necessary for understanding the nocturnal atmospheric boundary layer. The subtle nature of the interaction is exemplified in a phenomenon called the 'Ramdas paradox' or the 'lifted temperature minimum' (LTM), involving preferential cooling near the Earth's surface. The prevailing explanation for the LTM (the VSN model, Vasudeva Murthy et al (1993 Phil. Trans. R. Soc. A 344 183-206)) invokes radiative exchange in a homogeneous nocturnal atmosphere to predict a large cooling of the near-surface air layers. It is shown here that the cooling predicted by the VSN model is spurious, and that any preferential cooling can occur only in a heterogeneous atmosphere. The underlying error is fundamental, and occurs to varying degrees in a wide class of radiative models, in a flux-emissivity formulation, the VSN model being a prominent example. We, for the first time, propose the correct flux-emissivity formulation that eliminates spurious cooling. Results from field observations and laboratory experiments presented here, however, show that the near-surface radiative cooling is real; near-surface cooling rates can be orders of magnitude higher than values elsewhere in the boundary layer. The results presented include the dependence of the LTM on turbulence, the surface emissivity and the thermal inertia of the ground. It is proposed that aerosols provide the heterogeneity needed for the preferential cooling mechanism. Turbulence, by determining the aerosol concentration distribution over the relevant length scales, plays a key role in the phenomenon. Experimental evidence is presented to support this hypothesis.

  18. Hyper-cooling in the nocturnal boundary layer: the Ramdas paradox

    Energy Technology Data Exchange (ETDEWEB)

    Mukund, V; Ponnulakshmi, V K; Singh, D K; Subramanian, G; Sreenivas, K R, E-mail: krs@jncasr.ac.in [Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore (India)

    2010-12-15

    Characterizing the interaction between turbulence and radiative processes is necessary for understanding the nocturnal atmospheric boundary layer. The subtle nature of the interaction is exemplified in a phenomenon called the 'Ramdas paradox' or the 'lifted temperature minimum' (LTM), involving preferential cooling near the Earth's surface. The prevailing explanation for the LTM (the VSN model, Vasudeva Murthy et al (1993 Phil. Trans. R. Soc. A 344 183-206)) invokes radiative exchange in a homogeneous nocturnal atmosphere to predict a large cooling of the near-surface air layers. It is shown here that the cooling predicted by the VSN model is spurious, and that any preferential cooling can occur only in a heterogeneous atmosphere. The underlying error is fundamental, and occurs to varying degrees in a wide class of radiative models, in a flux-emissivity formulation, the VSN model being a prominent example. We, for the first time, propose the correct flux-emissivity formulation that eliminates spurious cooling. Results from field observations and laboratory experiments presented here, however, show that the near-surface radiative cooling is real; near-surface cooling rates can be orders of magnitude higher than values elsewhere in the boundary layer. The results presented include the dependence of the LTM on turbulence, the surface emissivity and the thermal inertia of the ground. It is proposed that aerosols provide the heterogeneity needed for the preferential cooling mechanism. Turbulence, by determining the aerosol concentration distribution over the relevant length scales, plays a key role in the phenomenon. Experimental evidence is presented to support this hypothesis.

  19. Hyper-cooling in the nocturnal boundary layer: the Ramdas paradox

    Science.gov (United States)

    Mukund, V.; Ponnulakshmi, V. K.; Singh, D. K.; Subramanian, G.; Sreenivas, K. R.

    2010-12-01

    Characterizing the interaction between turbulence and radiative processes is necessary for understanding the nocturnal atmospheric boundary layer. The subtle nature of the interaction is exemplified in a phenomenon called the 'Ramdas paradox' or the 'lifted temperature minimum' (LTM), involving preferential cooling near the Earth's surface. The prevailing explanation for the LTM (the VSN model, Vasudeva Murthy et al (1993 Phil. Trans. R. Soc. A 344 183-206)) invokes radiative exchange in a homogeneous nocturnal atmosphere to predict a large cooling of the near-surface air layers. It is shown here that the cooling predicted by the VSN model is spurious, and that any preferential cooling can occur only in a heterogeneous atmosphere. The underlying error is fundamental, and occurs to varying degrees in a wide class of radiative models, in a flux-emissivity formulation, the VSN model being a prominent example. We, for the first time, propose the correct flux-emissivity formulation that eliminates spurious cooling. Results from field observations and laboratory experiments presented here, however, show that the near-surface radiative cooling is real; near-surface cooling rates can be orders of magnitude higher than values elsewhere in the boundary layer. The results presented include the dependence of the LTM on turbulence, the surface emissivity and the thermal inertia of the ground. It is proposed that aerosols provide the heterogeneity needed for the preferential cooling mechanism. Turbulence, by determining the aerosol concentration distribution over the relevant length scales, plays a key role in the phenomenon. Experimental evidence is presented to support this hypothesis.

  20. Crowdsourcing urban air temperatures from smartphone battery temperatures

    NARCIS (Netherlands)

    Overeem, A.; Robinson, J.C.R.; Leijnse, H.; Steeneveld, G.J.; Horn, B.K.P.; Uijlenhoet, R.

    2013-01-01

    [1] Accurate air temperature observations in urban areas are important for meteorology and energy demand planning. They are indispensable to study the urban heat island effect and the adverse effects of high temperatures on human health. However, the availability of temperature observations in

  1. Air temperature gradient in large industrial hall

    Science.gov (United States)

    Karpuk, Michał; Pełech, Aleksander; Przydróżny, Edward; Walaszczyk, Juliusz; Szczęśniak, Sylwia

    2017-11-01

    In the rooms with dominant sensible heat load, volume airflow depends on many factors incl. pre-established temperature difference between exhaust and supply airflow. As the temperature difference is getting higher, airflow volume drops down, consequently, the cost of AHU is reduced. In high industrial halls with air exhaust grids located under the ceiling additional temperature gradient above working zone should be taken into consideration. In this regard, experimental research of the vertical air temperature gradient in high industrial halls were carried out for the case of mixing ventilation system The paper presents the results of air temperature distribution measurements in high technological hall (mechanically ventilated) under significant sensible heat load conditions. The supply airflow was delivered to the hall with the help of the swirl diffusers while exhaust grids were located under the hall ceiling. Basing on the air temperature distribution measurements performed on the seven pre-established levels, air temperature gradient in the area between 2.0 and 7.0 m above the floor was calculated and analysed.

  2. Nocturnal Hypertension and Attenuated Nocturnal Blood Pressure Dipping is Common in Pediatric Lupus

    Science.gov (United States)

    Campbell, J. Fallon; Swartz, Sarah J.; Wenderfer, Scott E.

    2015-01-01

    Hypertension is an important manifestation of systemic lupus erythematosus (SLE) but reports of prevalence vary between 20-70% in published reports of adult and pediatric patients. For both children and adults with SLE, the clinical diagnosis and management of hypertension has traditionally been based on guidelines developed for the general population. In clinical trials, the criteria used for defining participants with hypertension are mostly undefined. As a first step towards formally assessing the blood pressure (BP) patterns of children diagnosed with SLE, 24-hr ambulatory BP monitoring data was analyzed on clinic patients who presented with prehypertension or stage I hypertension. In this pediatric SLE cohort (n=10), 20% met daytime criteria for a diagnosis of hypertension. Patterns of BP elevation varied widely with white coat, masked, isolated systolic, and diastolic nocturnal hypertension all identified. Nocturnal hypertension was detected in 60% and attenuated nocturnal BP dipping in 90% of both hypertensive and normotensive SLE patients. In SLE patients, the median nighttime systolic and diastolic loads were 25% and 15.5% compared with median daily loads of 12.5% and 11.5%. Daytime and nighttime systolic and diastolic BP load and nocturnal dipping was compared to a control population consisting of 85 non-SLE patients under 21 years old with prehypertension or stage 1 hypertension presenting to hypertension clinic. Median systolic BP dipped 5.3 mmHg in SLE patients compared to 11.9 mmHg in non-lupus ( p-value = 0.001). Median diastolic BP dipped 12.9 mmHg versus 18.5 mmHg in non-lupus ( p-value = 0.003). Patterns of BP dysregulation in pediatric SLE merit further exploration. Children with or without SLE displaying prehypertensive or stage 1 casual BP measurements had similar rates of hypertension by ambulatory BP monitoring. However, regardless of BP diagnosis, and independent of kidney involvement, there was an increased proportion with attenuated

  3. Nowcasting daily minimum air and grass temperature

    Science.gov (United States)

    Savage, M. J.

    2016-02-01

    Site-specific and accurate prediction of daily minimum air and grass temperatures, made available online several hours before their occurrence, would be of significant benefit to several economic sectors and for planning human activities. Site-specific and reasonably accurate nowcasts of daily minimum temperature several hours before its occurrence, using measured sub-hourly temperatures hours earlier in the morning as model inputs, was investigated. Various temperature models were tested for their ability to accurately nowcast daily minimum temperatures 2 or 4 h before sunrise. Temperature datasets used for the model nowcasts included sub-hourly grass and grass-surface (infrared) temperatures from one location in South Africa and air temperature from four subtropical sites varying in altitude (USA and South Africa) and from one site in central sub-Saharan Africa. Nowcast models used employed either exponential or square root functions to describe the rate of nighttime temperature decrease but inverted so as to determine the minimum temperature. The models were also applied in near real-time using an open web-based system to display the nowcasts. Extrapolation algorithms for the site-specific nowcasts were also implemented in a datalogger in an innovative and mathematically consistent manner. Comparison of model 1 (exponential) nowcasts vs measured daily minima air temperatures yielded root mean square errors (RMSEs) <1 °C for the 2-h ahead nowcasts. Model 2 (also exponential), for which a constant model coefficient ( b = 2.2) was used, was usually slightly less accurate but still with RMSEs <1 °C. Use of model 3 (square root) yielded increased RMSEs for the 2-h ahead comparisons between nowcasted and measured daily minima air temperature, increasing to 1.4 °C for some sites. For all sites for all models, the comparisons for the 4-h ahead air temperature nowcasts generally yielded increased RMSEs, <2.1 °C. Comparisons for all model nowcasts of the daily grass

  4. Carbon dioxide measurements in the nocturnal boundary layer over Amazonian forest

    Directory of Open Access Journals (Sweden)

    A. D. Culf

    1999-01-01

    Full Text Available Measurements of carbon dioxide concentration, temperature and windspeed were made in the nocturnal boundary layer over a tropical forest near Manaus, Brazil using a tethered balloon system. The measurements were made up to a maximum height of 300 m on ten consecutive nights in November 1995. Simultaneous surface flux and in-canopy concentration measurements were made at the surface close to the site. The observation period included several different types of conditions. Generally strong windshear and relatively weak temperature gradients prevented the formation of a strong capping inversion to the nocturnal boundary layer. On some nights, however, the inversion was sufficiently strong that the CO2 concentration at 100 m above the surface exceeded 400 ppm. The concentration within the canopy was largely controlled by the presence of an inversion very close to the canopy surface. The temperature and wind profiles are contrasted with conditions in Randônia, Brazil, where the windshear was found to be weaker and higher carbon dioxide concentrations were observed in the early morning. The difference in carbon dioxide concentrations in the nocturnal boundary layer between dusk and dawn is used to estimate the regional nighttime flux of carbon dioxide. The value obtained generally exceeds the measured surface flux and sometimes exceeds the sum of the surface flux and the in-canopy storage made at the tower site. The reasons for the discrepancy are not clear; either one of the methods is in error or the regional carbon dioxide budget differs significantly from the local budget measured at the tower site.

  5. Moonstruck primates: owl monkeys (Aotus need moonlight for nocturnal activity in their natural environment.

    Directory of Open Access Journals (Sweden)

    Eduardo Fernández-Duque

    2010-09-01

    Full Text Available Primates show activity patterns ranging from nocturnality to diurnality, with a few species showing activity both during day and night. Among anthropoids (monkeys, apes and humans, nocturnality is only present in the Central and South American owl monkey genus Aotus. Unlike other tropical Aotus species, the Azara's owl monkeys (A. azarai of the subtropics have switched their activity pattern from strict nocturnality to one that also includes regular diurnal activity. Harsher climate, food availability, and the lack of predators or diurnal competitors, have all been proposed as factors favoring evolutionary switches in primate activity patterns. However, the observational nature of most field studies has limited an understanding of the mechanisms responsible for this switch in activity patterns. The goal of our study was to evaluate the hypothesis that masking, namely the stimulatory and/or inhibitory/disinhibitory effects of environmental factors on synchronized circadian locomotor activity, is a key determinant of the unusual activity pattern of Azara's owl monkeys. We use continuous long-term (6-18 months 5-min-binned activity records obtained with actimeter collars fitted to wild owl monkeys (n =  10 individuals to show that this different pattern results from strong masking of activity by the inhibiting and enhancing effects of ambient luminance and temperature. Conclusive evidence for the direct masking effect of light is provided by data showing that locomotor activity was almost completely inhibited when moonlight was shadowed during three lunar eclipses. Temperature also negatively masked locomotor activity, and this masking was manifested even under optimal light conditions. Our results highlight the importance of the masking of circadian rhythmicity as a determinant of nocturnality in wild owl monkeys and suggest that the stimulatory effects of dim light in nocturnal primates may have been selected as an adaptive response to

  6. Interactions between particulate air pollution and temperature in air pollution mortality time series studies

    International Nuclear Information System (INIS)

    Roberts, Steven

    2004-01-01

    In many community time series studies on the effect of particulate air pollution on mortality, particulate air pollution is modeled additively. In this study, we investigated the interaction between daily particulate air pollution and daily mean temperature in Cook County, Illinois and Allegheny County, Pennsylvania, using data for the period 1987-1994. This was done through the use of joint particulate air pollution-temperature response surfaces and by stratifying the effect of particulate air pollution on mortality by temperature. Evidence that the effect of particulate air pollution on mortality may depend on temperature is found. However, the results were sensitive to the number of degrees of freedom used in the confounder adjustments, the particulate air pollution exposure measure, and how the effects of temperature on mortality are modeled. The results were less sensitive to the estimation method used--generalized linear models and natural cubic splines or generalized additive models and smoothing splines. The results of this study suggest that in community particulate air pollution mortality time series studies the possibility of an interaction between daily particulate air pollution and daily mean temperature should be considered

  7. Undulator Hall Air Temperature Fault Scenarios

    International Nuclear Information System (INIS)

    Sevilla, J.

    2010-01-01

    Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about ±2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

  8. Increased nocturnal blood pressure in enuretic children with polyuria.

    Science.gov (United States)

    Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian

    2009-10-01

    We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.

  9. LED lighting increases the ecological impact of light pollution irrespective of color temperature.

    Science.gov (United States)

    Pawson, S M; Bader, M K-F

    Recognition of the extent and magnitude of night-time light pollution impacts on natural ecosystems is increasing, with pervasive effects observed in both nocturnal and diurnal species. Municipal and industrial lighting is on the cusp of a step change where energy-efficient lighting technology is driving a shift from “yellow” high-pressure sodium vapor lamps (HPS) to new “white” light-emitting diodes (LEDs). We hypothesized that white LEDs would be more attractive and thus have greater ecological impacts than HPS due to the peak UV-green-blue visual sensitivity of nocturnal invertebrates. Our results support this hypothesis; on average LED light traps captured 48% more insects than were captured with light traps fitted with HPS lamps, and this effect was dependent on air temperature (significant light × air temperature interaction). We found no evidence that manipulating the color temperature of white LEDs would minimize the ecological impacts of the adoption of white LED lights. As such, large-scale adoption of energy-efficient white LED lighting for municipal and industrial use may exacerbate ecological impacts and potentially amplify phytosanitary pest infestations. Our findings highlight the urgent need for collaborative research between ecologists and electrical engineers to ensure that future developments in LED technology minimize their potential ecological effects.

  10. The effects of adenotonsillotomy on nocturnal enuresis in snoring children

    Directory of Open Access Journals (Sweden)

    Marta Kostrzewa

    2017-12-01

    Full Text Available Introduction: Nocturnal enuresis is a common problem in the paediatric population. A number of reports indicate that there is a relationship between sleep-disordered breathing in children with tonsillar hypertrophy and nocturnal enuresis. Restoration of nasopharyngeal patency may eliminate nocturnal enuresis. Aim: The aim of the study was to evaluate the incidence of nocturnal enuresis in children snoring due to nasopharyngeal lymphatic tissue hypertrophy as well as to assess the effects of restored upper respiratory patency by means of adenectomy and tonsillectomy on the resolution of nocturnal enuresis in children. Material and methods: The study included 50 children with sleep-disordered breathing qualified for adenectomy, tonsillotomy or adenotonsillotomy (median age 7 years. The control group consisted of 20 healthy children (median age 8 years. Children in the study group were assessed prior to surgical procedure as well as 3 and 6 months after surgery. The presence of sleep-disordered breathing and nocturnal enuresis was determined based on author’s questionnaire completed by parents. Results: The incidence of nocturnal enuresis in children with nasopharyngeal lymphatic tissue hypertrophy was 18% (M:F 17%:19%; p > 0.05. Nocturnal enuresis was still reported in 6% of children 3 months after tonsillotomy. The disorder resolved in all girls and 97% of boys 6 months after procedure. Conclusions: Sleep-disordered breathing in children with nasopharyngeal lymphatic tissue hypertrophy is associated with nocturnal enuresis. Restoration of nasopharyngeal patency in these patients eliminates nocturnal enuresis. Tonsillar hypertrophy causing obstructive breathing should be included in the differential diagnosis of nocturnal enuresis.

  11. Air temperature investigation in microenvironment around a human body

    DEFF Research Database (Denmark)

    Licina, Dusan; Melikov, Arsen Krikor; Sekhar, Chandra

    2015-01-01

    The aim of this study is to investigate the temperature boundary layer around a human body in a quiescent indoor environment. The air temperature, mean in time and standard deviation of the temperature fluctuations around a breathing thermal manikin are examined in relation to the room temperature......, body posture and human respiratory flow. To determine to what extent the experiments represent the realistic scenario, the additional experiments were performed with a real human subject. The results show that at a lower room air temperature (20°C), the fluctuations of air temperature increased close...... to the surface of the body. The large standard deviation of air temperature fluctuations, up to 1.2°C, was recorded in the region of the chest, and up to 2.9°C when the exhalation was applied. The manikin leaned backwards increased the air temperature in the breathing zone, which was opposite from the forward...

  12. Estimation of bare soil surface temperature from air temperature and ...

    African Journals Online (AJOL)

    Soil surface temperature has critical influence on climate, agricultural and hydrological activities since it serves as a good indicator of the energy budget of the earth's surface. Two empirical models for estimating soil surface temperature from air temperature and soil depth temperature were developed. The coefficient of ...

  13. Assessment of broiler surface temperature variation when exposed to different air temperatures

    Directory of Open Access Journals (Sweden)

    GR Nascimento

    2011-12-01

    Full Text Available This study was conducted to determine the effect of the air temperature variation on the mean surface temperature (MST of 7- to 35-day-old broiler chickens using infrared thermometry to estimate MST, and to study surface temperature variation of the wings, head, legs, back and comb as affected by air temperature and broiler age. One hundred Cobb® broilers were used in the experiment. Starting on day 7, 10 birds were weekly selected at random, housed in an environmental chamber and reared under three distinct temperatures (18, 25 and 32 ºC to record their thermal profile using an infrared thermal camera. The recorded images were processed to estimate MST by selecting the whole area of the bird within the picture and comparing it with the values obtained using selected equations in literature, and to record the surface temperatures of the body parts. The MST estimated by infrared images were not statistically different (p > 0.05 from the values obtained by the equations. MST values significantly increased (p < 0.05 when the air temperature increased, but were not affected by bird age. However, age influenced the difference between MST and air temperature, which was highest on day 14. The technique of infrared thermal image analysis was useful to estimate the mean surface temperature of broiler chickens.

  14. Analysis of nocturia with 24-h urine volume, nocturnal urine volume, nocturnal bladder capacity and length of sleep duration: concept for effective treatment modality.

    Science.gov (United States)

    Udo, Yukihiro; Nakao, Masahiro; Honjo, Hisashi; Ukimura, Osamu; Kawauchi, Akihiro; Kitakoji, Hiroshi; Miki, Tsuneharu

    2011-03-01

    • To determine the relationship between the number of nocturia and 24-h urine volume, nocturnal urine volume, nocturnal bladder capacity and length of sleep duration as well as to assess the significance of these factors with respect to eliminating nocturnal voidings in individual patients with nocturia. • Among 532 participants who completed a 3-day bladder diary between April 2005 and December 2006, the diaries of 450 participants without 24-h polyuria were analyzed. • Clinical variables such as the number of daytime and night-time voids, 24-h urine volume, nocturnal polyuria index, daytime and night-time maximum voided volumes (MVV), night/day MVV ratio, sleep duration and proportion of night/day urine production rates were obtained from each diary. • Participants were classified into eight groups according to values of three factors: nocturnal MVV, proportion of night/day urine production rates and length of sleep duration. • Each group was divided into three subgroups: non-nocturics (number of nocturnal voidings is zero), mild nocturics (number of nocturnal voidings is one) and severe nocturics (number of nocturnal voidings is two or more). • The data from non-nocturics with three normal factors were regarded as the normal control and compared with the variables of the other subgroups using Dunnett's method. • Variables that form the basis of classifying participants into eight groups and corresponding to abnormal factors of each group were statistically significant in all the subgroups of each group. • Furthermore, a significantly increased 24-h urine volume was found in severe nocturics of the group with three normal factors. • A significantly decreased 24-h urine volume was found in non-nocturics of groups with nocturnal polyuria, decreased bladder capacity and both long sleep duration and nocturnal polyuria. • A significantly increased nocturnal MVV and night/day MVV ratio were shown in non-nocturics and mild nocturics of the groups

  15. Nocturnal bees are attracted by widespread floral scents.

    Science.gov (United States)

    Carvalho, Airton Torres; Maia, Artur Campos Dalia; Ojima, Poliana Yumi; dos Santos, Adauto A; Schlindwein, Clemens

    2012-03-01

    Flower localization in darkness is a challenging task for nocturnal pollinators. Floral scents often play a crucial role in guiding them towards their hosts. Using common volatile compounds of floral scents, we trapped female nocturnal Megalopta-bees (Halictidae), thus uncovering olfactory cues involved in their search for floral resources. Applying a new sampling method hereby described, we offer novel perspectives on the investigation of nocturnal bees.

  16. 40 CFR 89.325 - Engine intake air temperature measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature measurement. 89.325 Section 89.325 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air...

  17. Observational assessment of the role of nocturnal residual-layer chemistry in determining daytime surface particulate nitrate concentrations

    Directory of Open Access Journals (Sweden)

    G. Prabhakar

    2017-12-01

    Full Text Available This study discusses an analysis of combined airborne and ground observations of particulate nitrate (NO3−(p concentrations made during the wintertime DISCOVER-AQ (Deriving Information on Surface Conditions from COlumn and VERtically resolved observations relevant to Air Quality study at one of the most polluted cities in the United States – Fresno, CA – in the San Joaquin Valley (SJV and focuses on developing an understanding of the various processes that impact surface nitrate concentrations during pollution events. The results provide an explicit case-study illustration of how nighttime chemistry can influence daytime surface-level NO3−(p concentrations, complementing previous studies in the SJV. The observations exemplify the critical role that nocturnal chemical production of NO3−(p aloft in the residual layer (RL can play in determining daytime surface-level NO3−(p concentrations. Further, they indicate that nocturnal production of NO3−(p in the RL, along with daytime photochemical production, can contribute substantially to the buildup and sustaining of severe pollution episodes. The exceptionally shallow nocturnal boundary layer (NBL heights characteristic of wintertime pollution events in the SJV intensify the importance of nocturnal production aloft in the residual layer to daytime surface concentrations. The observations also demonstrate that dynamics within the RL can influence the early-morning vertical distribution of NO3−(p, despite low wintertime wind speeds. This overnight reshaping of the vertical distribution above the city plays an important role in determining the net impact of nocturnal chemical production on local and regional surface-level NO3−(p concentrations. Entrainment of clean free-tropospheric (FT air into the boundary layer in the afternoon is identified as an important process that reduces surface-level NO3−(p and limits buildup during pollution episodes. The influence of dry deposition of HNO

  18. Pathophysiology of nocturnal lower urinary tract symptoms in older patients with urinary incontinence.

    Science.gov (United States)

    Denys, Marie-Astrid; Decalf, Veerle; Kumps, Candy; Petrovic, Mirko; Goessaert, An-Sofie; Everaert, Karel

    2017-11-01

    To explore the mismatch between functional bladder capacity and nocturnal urine production, and to study the pathophysiology of an increased nocturnal urine production in older patients with urinary incontinence. The present prospective observational study included adults aged ≥65 years with urinary incontinence. Participants completed questionnaires, frequency volume charts and renal function profiles. The nocturnal lower urinary tract symptom index was defined as nocturnal urine output/maximum voided volume; the nocturnal polyuria index as nocturnal/24 h urine output. The median age (n = 95) was 74 years (69-79), 87% were women and 73% had nocturnal lower urinary tract symptoms (nocturnal urinary incontinence or nocturia ≥2). Participants with nocturnal lower urinary tract symptoms had a significantly higher nocturnal urine output (809 mL vs 650 mL; P = 0.001) and no significant difference in maximum voided volume (350 mL vs 437 mL; P = 0.079) compared with participants without nocturnal lower urinary tract symptoms. Participants (nocturnal polyuria index >33% [n = 56], nocturnal polyuria index >40% [n = 42], nocturnal lower urinary tract symptom index >1.87 [n = 51]) showed higher night-time diuresis rates, free water and sodium clearance compared with during the daytime. Controls (nocturnal polyuria index ≤33% [n = 26], nocturnal polyuria index ≤40% [n = 40], nocturnal lower urinary tract symptom index ≤1.87 [n = 44]) had no circadian rhythm in their diuresis rate or sodium clearance, but more nocturnal free water clearance compared with during the daytime. The majority of older adults with urinary incontinence present nocturnal lower urinary tract symptoms. An increased nocturnal sodium diuresis seems to be the only mechanism differentiating patients with nocturnal lower urinary tract symptoms from controls. © 2017 The Japanese Urological Association.

  19. The Influence of Air Temperature on the Dew Point Temperature in ...

    African Journals Online (AJOL)

    ADOWIE PERE

    done to determine the influence and effect of temperature on other climatic environmental ... Key words: Air Temperature, Dew point temperature, Weather, Climate, Influence. Weather ... humidity, clouds and atmospheric pressure. Its.

  20. Projections of precipitation, air temperature and potential ...

    African Journals Online (AJOL)

    mabouelhaggag

    Precipitation and air temperature records from 6 sites in Rwanda in the period from 1964 to 2010 are used for past/present climate assessment. Future climate projections (2010-2099) based on 3 general circulation models and 2 emission scenarios (A2 and B1) are used for climate projections. Precipitation, air temperature ...

  1. 40 CFR 91.309 - Engine intake air temperature measurement.

    Science.gov (United States)

    2010-07-01

    ... measurement. 91.309 Section 91.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 100 cm of the air-intake of the engine. The measurement location must be either in...

  2. Solar activity influence on air temperature regimes in caves

    Science.gov (United States)

    Stoeva, Penka; Mikhalev, Alexander; Stoev, Alexey

    Cave atmospheres are generally included in the processes that happen in the external atmosphere as circulation of the cave air is connected with the most general circulation of the air in the earth’s atmosphere. Such isolated volumes as the air of caves are also influenced by the variations of solar activity. We discuss cave air temperature response to climate and solar and geomagnetic activity for four show caves in Bulgaria studied for a period of 46 years (1968 - 2013). Everyday noon measurements in Ledenika, Saeva dupka, Snezhanka and Uhlovitsa cave have been used. Temperatures of the air in the zone of constant temperatures (ZCT) are compared with surface temperatures recorded at meteorological stations situated near about the caves - in the towns of Vratsa, Lovech, Peshtera and Smolyan, respectively. For comparison, The Hansen cave, Middle cave and Timpanogos cave from the Timpanogos Cave National Monument, Utah, USA situated nearly at the same latitude have also been examined. Our study shows that the correlation between cave air temperature time series and sunspot number is better than that between the cave air temperature and Apmax indices; that t°ZCT is rather connected with the first peak in geomagnetic activity, which is associated with transient solar activity (CMEs) than with the second one, which is higher and connected with the recurrent high speed streams from coronal holes. Air temperatures of all examined show caves, except the Ledenika cave, which is ice cave show decreasing trends. On the contrary, measurements at the meteorological stations show increasing trends in the surface air temperatures. The trend is decreasing for the Timpanogos cave system, USA. The conclusion is that surface temperature trends depend on the climatic zone, in which the cave is situated, and there is no apparent relation between temperatures inside and outside the caves. We consider possible mechanism of solar cosmic rays influence on the air temperatures in caves

  3. CDC WONDER: Daily Air Temperatures and Heat Index

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Daily Air Temperature and Heat Index data available on CDC WONDER are county-level daily average air temperatures and heat index measures spanning the years...

  4. The impact of draught related to air velocity, air temperature and workload.

    Science.gov (United States)

    Griefahn, B; Künemund, C; Gehring, U

    2001-08-01

    This experimental study was designed to test the hypotheses that the effects of draught increase with higher air velocity, with lower air temperature, and with lower workload. Thirty healthy young males were exposed to horizontal draught during 55 min while they operated an arm ergometer in a standing posture. Air velocity, air temperature, and workload were varied in 3 steps each, between 11 and 23 degrees C, 0.1 and 0.3 m/s, and 104 to 156 W/m2, respectively. The 27 combinations were distributed over subjects in a fractional factorial 3(3)-design. The participants were clothed for thermal neutrality. Workload was measured at the end of the sessions by respirometry. Draught-induced annoyance was determined every 5 min, separately for 10 body sites. Corresponding skin temperature was also recorded. The hypotheses were verified for the influence of air velocity and air temperature. Regarding workload, local heat production is probably decisive, meaning that draft-induced local annoyance is inversely related to workload in active but independent from workload in non-active body areas. To improve the situation for the workers concerned it is suggested to apply protective gloves that cover an as great area of the forearms as possible and to limit airflows to mean velocities of less than 0.2 m/s (with turbulence intensities of 50%).

  5. Nocturnal Eating: Association with Binge Eating, Obesity, and Psychological Distress

    Science.gov (United States)

    Striegel-Moore, Ruth H.; Rosselli, Francine; Wilson, G. Terence; Perrin, Nancy; Harvey, Kate; DeBar, Lynn

    2009-01-01

    Objective To examine clinical correlates of nocturnal eating, a core behavioral symptom of night eating syndrome. Method Data from 285 women who had participated in a two-stage screening for binge eating were utilized. Women (n = 41) who reported one or more nocturnal eating episodes in the past 28 days on the Eating Disorder Examination and women who did not report nocturnal eating (n =244) were compared on eating disorder symptomatology, Body Mass Index (BMI), and on measures of psychosocial adjustment. Results Nocturnal eaters were significantly more likely to report binge eating and differed significantly from non-nocturnal eaters (with responses indicating greater disturbance) on weight and shape concern, eating concern, self-esteem, depression, and functional impairment, but not on BMI or dietary restraint. Group differences remained significant in analyses adjusting for binge eating. Conclusions This study confirms the association between nocturnal eating and binge eating previously found in treatment seeking samples yet also suggests that the elevated eating disorder symptoms and decreased psychosocial adjustment observed in nocturnal eaters is not simply a function of binge eating. PMID:19708071

  6. Nocturnal Oviposition Behavior of Forensically Important Diptera in Central England.

    Science.gov (United States)

    Barnes, Kate M; Grace, Karon A; Bulling, Mark T

    2015-11-01

    Timing of oviposition on a corpse is a key factor in entomologically based minimum postmortem interval (mPMI) calculations. However, there is considerable variation in nocturnal oviposition behavior of blow flies reported in the research literature. This study investigated nocturnal oviposition in central England for the first time, over 25 trials from 2011 to 2013. Liver-baited traps were placed in an urban location during control (diurnal), and nocturnal periods and environmental conditions were recorded during each 5-h trial. No nocturnal activity or oviposition was observed during the course of the study indicating that nocturnal oviposition is highly unlikely in central England. © 2015 American Academy of Forensic Sciences.

  7. Nocturnal Gastroesophageal Reflux Revisited by Impedance-pH Monitoring

    Science.gov (United States)

    Blondeau, Kathleen; Mertens, Veerle; Tack, Jan; Sifrim, Daniel

    2011-01-01

    Background/Aims Impedance-pH monitoring allows detailed characterization of gastroesophageal reflux and esophageal activity associated with reflux. We assessed the characteristics of nocturnal reflux and esophageal activity preceding and following reflux. Methods Impedance-pH tracings from 11 healthy subjects and 76 patients with gastroesophageal reflux disease off acid-suppressive therapy were analyzed. Characteristics of nocturnal supine reflux, time distribution and esophageal activity seen on impedance at 2 minute intervals preceding and following reflux were described. Results Patients had more nocturnal reflux events than healthy subjects (8 [4-12] vs 2 [1-5], P = 0.002), with lower proportion of weakly acidic reflux (57% [35-78] vs 80% [60-100], P = 0.044). Nocturnal reflux was mainly liquid (80%) and reached the proximal esophagus more often in patients (6% vs 0%, P = 0.047). Acid reflux predominated in the first 2 hours (66%) and weakly acidic reflux in the last 3 hours (70%) of the night. Most nocturnal reflux was preceded by aboral flows and cleared by short lasting volume clearance. In patients, prolonged chemical clearance was associated with less esophageal activity. Conclusions Nocturnal weakly acidic reflux is as common as acid reflux in patients with gastroesophageal reflux disease, and predominates later in the night. Impedance-pH can predict prolonged chemical clearance after nocturnal acid reflux. PMID:21602991

  8. Soil and air temperatures for different habitats in Mount Rainier National Park.

    Science.gov (United States)

    Sarah E. Greene; Mark Klopsch

    1985-01-01

    This paper reports air and soil temperature data from 10 sites in Mount Rainier National Park in Washington State for 2- to 5-year periods. Data provided are monthly summaries for day and night mean air temperatures, mean minimum and maximum air temperatures, absolute minimum and maximum air temperatures, range of air temperatures, mean soil temperature, and absolute...

  9. 40 CFR 90.309 - Engine intake air temperature measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature measurement. 90.309 Section 90.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...

  10. Improving Forecast Skill by Assimilation of AIRS Temperature Soundings

    Science.gov (United States)

    Susskind, Joel; Reale, Oreste

    2010-01-01

    AIRS was launched on EOS Aqua on May 4, 2002, together with AMSU-A and HSB, to form a next generation polar orbiting infrared and microwave atmospheric sounding system. The primary products of AIRS/AMSU-A are twice daily global fields of atmospheric temperature-humidity profiles, ozone profiles, sea/land surface skin temperature, and cloud related parameters including OLR. The AIRS Version 5 retrieval algorithm, is now being used operationally at the Goddard DISC in the routine generation of geophysical parameters derived from AIRS/AMSU data. A major innovation in Version 5 is the ability to generate case-by-case level-by-level error estimates delta T(p) for retrieved quantities and the use of these error estimates for Quality Control. We conducted a number of data assimilation experiments using the NASA GEOS-5 Data Assimilation System as a step toward finding an optimum balance of spatial coverage and sounding accuracy with regard to improving forecast skill. The model was run at a horizontal resolution of 0.5 deg. latitude X 0.67 deg longitude with 72 vertical levels. These experiments were run during four different seasons, each using a different year. The AIRS temperature profiles were presented to the GEOS-5 analysis as rawinsonde profiles, and the profile error estimates delta (p) were used as the uncertainty for each measurement in the data assimilation process. We compared forecasts analyses generated from the analyses done by assimilation of AIRS temperature profiles with three different sets of thresholds; Standard, Medium, and Tight. Assimilation of Quality Controlled AIRS temperature profiles significantly improve 5-7 day forecast skill compared to that obtained without the benefit of AIRS data in all of the cases studied. In addition, assimilation of Quality Controlled AIRS temperature soundings performs better than assimilation of AIRS observed radiances. Based on the experiments shown, Tight Quality Control of AIRS temperature profile performs best

  11. NOCTURNAL AIR-FLOW OBSTRUCTION, HISTAMINE, AND THE AUTONOMIC CENTRAL-NERVOUS-SYSTEM IN CHILDREN WITH ALLERGIC-ASTHMA

    NARCIS (Netherlands)

    VANAALDEREN, WMC; POSTMA, DS; KOETER, GH; KNOL, K

    A study was carried out to investigate whether an imbalance in the autonomic nervous system or release of histamine, or both, is responsible for the nocturnal increase in airflow obstruction in asthmatic children. The study comprised 18 children with allergic asthma,nine with (group 1) and nine

  12. Iatrogenic nocturnal eneuresis- an overlooked side effect of anti histamines?

    Directory of Open Access Journals (Sweden)

    D Italiano

    2015-01-01

    Full Text Available Nocturnal enuresis is a common disorder in childhood, but its pathophysiological mechanisms have not been fully elucidated. Iatrogenic nocturnal enuresis has been described following treatment with several psychotropic medications. Herein, we describe a 6-year-old child who experienced nocturnal enuresis during treatment with the antihistamine cetirizine. Drug rechallenge was positive. Several neurotransmitters are implicated in the pathogenesis of nocturnal enuresis, including noradrenaline, serotonin and dopamine. Antihistamine treatment may provoke functional imbalance of these pathways resulting in incontinence.

  13. Study of cross-spectra of velocity components and temperature series in a nocturnal boundary layer

    Science.gov (United States)

    Maqueda, Gregorio; Sastre, Mariano; Viñas, Carmen; Viana, Samuel; Yagüe, Carlos

    2010-05-01

    The main characteristic of the Planetary Boundary Layer is the turbulent flow that can be understood as the motions of many superimposed eddies with different scales, which are very irregular and produce mixing among the atmospheric properties. Spectral analysis is a widely used statistical tool to know the size of eddies into the flow. The Turbulent Kinetic Energy is split in fractions for each scale of eddy by mean the power spectrum of the wind velocity components. Also, the fluctuation of the other variables as temperature, humidity, gases concentrations or material particles presents in the atmosphere can be divided according to the importance of different scales in a similar way than the wind. A Cross-spectrum between two time series is used in meteorology to know their correlation in frequency space. Specially, coespectrum, or real part of cross-spectrum, amplitud and coherence give us many information about the low or high correlation between two variables in a particular frecuency or scale (Stull, 1988). In this work we have investigated cross-spectra of velocity components and temperature measured along the summer 2009 at the CIBA, Research Centre for the Lower Atmosphere, located in Valladolid province (Spain), which is on a quite flat terrain (Cuxart et al., 2000; Viana et al., 2009). In these experimental dataset, among other instrumentation, two sonic anemometers (20 Hz, sampling rate) at 1.5 m and 10 m height are available. Cross-spectra between variables of the two levels, specially, wind vertical component and sonic temperature, under stable stratification are studied in order to improve the knowledge of the proprieties of the momentum and heat fluxes near the ground in the PBL. Nevertheless, power spectral of horizontal components of the wind, at both levels, have been also analysed. The spectra and cross-spectra were performed by mean the Blackman-Tukey method, widely utilised in the time series studies (Blackman & Tukey, 1958) and, where it is

  14. Desmopressin is an effective treatment for mixed nocturia with nocturnal polyuria and decreased nocturnal bladder capacity.

    Science.gov (United States)

    Lee, Hye Won; Choo, Myung-Soo; Lee, Jeong Gu; Park, Choal Hee; Paick, Jae-Seung; Lee, Jeong Zoo; Han, Deok Hyun; Park, Won Hee; Lee, Kyu-Sung

    2010-12-01

    To investigate the efficacy and safety of desmopressin in patients with mixed nocturia, Patients aged ≥ 18 yr with mixed nocturia (≥ 2 voids/night and a nocturnal polyuria index [NPi] >33% and a nocturnal bladder capacity index [NBCi] >1) were recruited. The optimum dose of oral desmopressin was determined during a 3-week dose-titration period and the determined dose was maintained for 4 weeks. The efficacy was assessed by the frequency-volume charts and the sleep questionnaire. The primary endpoint was the proportion of patients with a 50% or greater reduction in the number of nocturnal voids (NV) compared with baseline. Among 103 patients enrolled, 94 (79 men and 15 women) were included in the analysis. The proportion of patients with a 50% or greater reduction in NV was 68 (72%). The mean number of NV decreased significantly (3.20 to 1.34) and the mean nocturnal urine volume, nocturia index, NPi, and NBCi decreased significantly. The mean duration of sleep until the first NV was prolonged from 118.4 ± 44.1 to 220.3 ± 90.7 min (P<0.001). The overall impression of patients about their quality of sleep improved. Adverse events occurred in 6 patients, including one asymptomatic hyponatremia. Desmopressin is an effective and well-tolerated treatment for mixed nocturia.

  15. Vertical Distribution of Daily Migrating Mesopelagic Fish in Respect to Nocturnal Lights

    KAUST Repository

    Prihartato, Perdana

    2014-12-01

    The nighttime distribution of vertically migrating mesopelagic fish in relation to nocturnal light was studied during a circumglobal survey, in the Red Sea, and in a fjord at high latitude. The study was based on data derived from ship borne echo sounders (circumglobal and the Red Sea) as well as using upward looking echo sounders mounted on the bottom (Masfjorden, Norway). We also applied a numerical model for analyzing diel vertical migration patterns. The effect of the lunar cycle was the focus in studies at low latitudes, while seasonal changes in nocturnal light climate was in focus at high latitude. Lunar phase significantly affected the distribution of mesopelagic fish at the global scale and in the Red Sea. During nights near full moon, scattering layers of mesopelagic fish distributed deeper than during darker phases of the moon. At high latitude, mesopelagic fish switched its behavior along with seasonal changes in nocturnal lights. In autumn, the population of the studied fish (Maurolicus mueleri) formed separated layers. Juveniles performed normal diel vertical migration followed by midnight sinking, with midnight sinking mainly related to temperature minima and also for avoiding predators. Meanwhile the adults did not migrate vertically, reducing foraging but increasing the adult survival. From late winter to mid-Spring, interrupted ascents behavior was noted in the afternoon. Predator avoidance, satiation, and finding temperature optimum might be the reason behind interrupted ascents. At lighter nights in mid-summer, M. muelleri took on schooling behavior, likely as an anti-predator behavior permitting access to the upper waters in the absence of darkness.

  16. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  17. Nocturnal enuresis in india: Are we diagnosing and managing correctly?

    Directory of Open Access Journals (Sweden)

    N M Reddy

    2017-01-01

    Full Text Available Nocturnal enuresis is a common problem affecting school-aged children worldwide. Although it has significant impact on child's psychology, it is always under-recognized in India and considered as a condition which will outgrow with advancing age. Nocturnal enuresis classified as primary or secondary and monosymptomatic or nonmonosymptomatic. Factors that cause enuresis include genetic factors, bladder dysfunction, psychological factors, and inappropriate antidiuretic hormone secretion, leading to nocturnal polyuria. Diagnosis consists of detailed medical history, clinical examination, frequency-volume charts, and appropriate investigations. The frequency-volume chart or voiding diary helps in establishing diagnosis and tailoring therapy. The first step in treating nocturnal enuresis is to counsel the parents and the affected child about the condition and reassure them that it can be cured. One of the effective strategies to manage enuresis is alarm therapy, but currently, it is not easily available in India. Desmopressin has been used in the treatment of nocturnal enuresis for close to 50 years. It provides an effective and safe option for the management of nocturnal enuresis. This review covers the diagnosis and management of nocturnal enuresis and introduces the concept of “bedwetting clinics” in India, which should help clinicians in the thorough investigation of bedwetting cases.

  18. Circadian Rhythm of Glomerular Filtration and Solute Handling Related to Nocturnal Enuresis.

    Science.gov (United States)

    Dossche, L; Raes, A; Hoebeke, P; De Bruyne, P; Vande Walle, J

    2016-01-01

    Although nocturnal polyuria in patients with monosymptomatic enuresis can largely be explained by the decreased nocturnal vasopressin secretion hypothesis, other circadian rhythms in the kidney also seem to have a role. We recently documented an absent day/night rhythm in a subgroup of desmopressin refractory cases. We explore the importance of abnormal circadian rhythm of glomerular filtration and tubular (sodium, potassium) parameters in patients with monosymptomatic enuresis. In this retrospective study of a tertiary enuresis population we collected data subsequent to a standardized screening (International Children's Continence Society questionnaire), 14-day diary for nocturnal enuresis and diuresis, and 24-hour concentration profile. The study population consisted of 139 children with nocturnal enuresis who were 5 years or older. Children with nonmonosymptomatic nocturnal enuresis were used as controls. There was a maintained circadian rhythm of glomerular filtration, sodium, osmotic excretion and diuresis rate in children with monosymptomatic and nonmonosymptomatic nocturnal enuresis, and there was no difference between the 2 groups. Secondary analysis revealed that in patients with nocturnal polyuria (with monosymptomatic or nonmonosymptomatic nocturnal enuresis) circadian rhythm of glomerular filtration, sodium and osmotic excretion, and diuresis rate was diminished in contrast to those without nocturnal polyuria (p Circadian rhythm of the kidney does not differ between patients with nonmonosymptomatic and monosymptomatic enuresis. However, the subgroup with enuresis and nocturnal polyuria has a diminished circadian rhythm of nocturnal diuresis, sodium excretion and glomerular filtration in contrast to children without nocturnal polyuria. This observation cannot be explained by the vasopressin theory alone. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Nocturnal polyuria is related to absent circadian rhythm of glomerular filtration rate.

    Science.gov (United States)

    De Guchtenaere, A; Vande Walle, C; Van Sintjan, P; Raes, A; Donckerwolcke, R; Van Laecke, E; Hoebeke, P; Vande Walle, J

    2007-12-01

    Monosymptomatic nocturnal enuresis is frequently associated with nocturnal polyuria and low urinary osmolality during the night. Initial studies found decreased vasopressin levels associated with low urinary osmolality overnight. Together with the documented desmopressin response, this was suggestive of a primary role for vasopressin in the pathogenesis of enuresis in the absence of bladder dysfunction. Recent studies no longer confirm this primary role of vasopressin. Other pathogenetic factors such as disordered renal sodium handling, hypercalciuria, increased prostaglandins and/or osmotic excretion might have a role. So far, little attention has been given to abnormalities in the circadian rhythm of glomerular filtration rate. We evaluated the circadian rhythm of glomerular filtration rate and diuresis in children with desmopressin resistant monosymptomatic nocturnal enuresis and nocturnal polyuria. We evaluated 15 children (9 boys) 9 to 14 years old with monosymptomatic nocturnal enuresis and nocturnal polyuria resistant to desmopressin treatment. The control group consisted of 25 children (12 boys) 9 to 16 years old with monosymptomatic nocturnal enuresis without nocturnal polyuria. Compared to the control population, children with nocturnal polyuria lost their circadian rhythm not only for diuresis and sodium excretion but also for glomerular filtration rate. Patients with monosymptomatic nocturnal enuresis and nocturnal polyuria lack a normal circadian rhythm for diuresis and sodium excretion, and the circadian rhythm of glomerular filtration rate is absent. This absence of circadian rhythm of glomerular filtration rate and/or sodium handling cannot be explained by a primary role of vasopressin, but rather by a disorder in circadian rhythm of renal glomerular and/or tubular functions.

  20. Eye shape and the nocturnal bottleneck of mammals.

    Science.gov (United States)

    Hall, Margaret I; Kamilar, Jason M; Kirk, E Christopher

    2012-12-22

    Most vertebrate groups exhibit eye shapes that vary predictably with activity pattern. Nocturnal vertebrates typically have large corneas relative to eye size as an adaptation for increased visual sensitivity. Conversely, diurnal vertebrates generally demonstrate smaller corneas relative to eye size as an adaptation for increased visual acuity. By contrast, several studies have concluded that many mammals exhibit typical nocturnal eye shapes, regardless of activity pattern. However, a recent study has argued that new statistical methods allow eye shape to accurately predict activity patterns of mammals, including cathemeral species (animals that are equally likely to be awake and active at any time of day or night). Here, we conduct a detailed analysis of eye shape and activity pattern in mammals, using a broad comparative sample of 266 species. We find that the eye shapes of cathemeral mammals completely overlap with nocturnal and diurnal species. Additionally, most diurnal and cathemeral mammals have eye shapes that are most similar to those of nocturnal birds and lizards. The only mammalian clade that diverges from this pattern is anthropoids, which have convergently evolved eye shapes similar to those of diurnal birds and lizards. Our results provide additional evidence for a nocturnal 'bottleneck' in the early evolution of crown mammals.

  1. Fast Air Temperature Sensors

    DEFF Research Database (Denmark)

    Hendricks, Elbert

    1998-01-01

    The note documents briefly work done on a newly developed sensor for making fast temperature measurements on the air flow in the intake ports of an SI engine and in the EGR input line. The work reviewed has been carried out in close cooperation with Civ. Ing. Michael Føns, the author (IAU...

  2. Observations and models of simple nocturnal slope flows

    International Nuclear Information System (INIS)

    Doran, J.C.; Horst, J.W.

    1983-01-01

    Measurements of simple nocturnal slope winds were taken on Rattlesnake Mountain, a nearly ideal two-dimensional ridge. Tower and tethered balloon instrumentation allowed the determination of the wind and temperature characteristics of the katabatic layer as well as the ambient conditions. Two cases were chosen for study; these were marked by well-defined surface-based temperature inversions and a low-level maximum in the downslope wind component. The downslope development of the slope flow could be determined from the tower measurements, and showed a progressive strenghtening of the katabatic layer. Hydraulic models developed by Manins and Sawford (1979a) and Briggs (1981) gave useful estimates of drainage layer depths, but were not otherwise applicable. A simple numerical model that relates the eddy diffusivity to the local turbulent kinetic energy was found to give good agreement with the observed wind and temperature profiles of the slope flows

  3. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    Air-conditioning is not only a matter of temperature control. Thermal comfort and good indoor air quality are mainly a matter of humidity. Human health and well being may suffer seriously from inadequate humidity and/or too low temperatures in a room. A case study involving supermarket air......%. For indoor air temperature and humidity control, the use of an ice slurry (´Binary Ice´)was compared to conventional chilled water. The use of Binary Ice instead of chilled water makes the air handling and air distribution installation much simpler, recirculation of air becomes obsolete, and a higher portion...... of ambient air can be supplied, thus improving the indoor air quality still further. Reheating of air is not necessary when using Binary Ice. The introduction of chilled air into a room requires a different type of air outlet, however. When using Binary Ice, energy savings are high for climates with low...

  4. Dark Matters: Challenges of Nocturnal Communication Between Plants and Animals in Delivery of Pollination Services.

    Science.gov (United States)

    Borges, Renee M

    2018-03-01

    The night is a special niche characterized by dim light, lower temperatures, and higher humidity compared to the day. Several animals have made the transition from the day into the night and have acquired unique adaptations to cope with the challenges of performing nocturnal activities. Several plant species have opted to bloom at night, possibly as a response to aridity to prevent excessive water loss through evapotranspiration since flowering is often a water-demanding process, or to protect pollen from heat stress. Nocturnal pollinators have visual adaptations to function under dim light conditions but may also trade off vision against olfaction when they are dependent on nectar-rewarding and scented flowers. Nocturnal pollinators may use CO 2 and humidity cues emanating from freshly-opened flowers as indicators of nectar-rich resources. Some endothermic nocturnal insect pollinators are attracted to thermogenic flowers within which they remain to obtain heat as a reward to increase their energy budget. This review focuses on mechanisms that pollinators use to find flowers at night, and the signals that nocturnally blooming flowers may employ to attract pollinators under dim light conditions. It also indicates gaps in our knowledge. While millions of years of evolutionary time have given pollinators and plants solutions to the delivery of pollination services and to the offering of appropriate rewards, this history of successful evolution is being threatened by artificial light at night. Excessive and inappropriate illumination associated with anthropogenic activities has resulted in significant light pollution which serves to undermine life processes governed by dim light.

  5. Communal nesting under climate change: fitness consequences of higher incubation temperatures for a nocturnal lizard.

    Science.gov (United States)

    Dayananda, Buddhi; Gray, Sarah; Pike, David; Webb, Jonathan K

    2016-07-01

    Communal nesting lizards may be vulnerable to climate warming, particularly if air temperatures regulate nest temperatures. In southeastern Australia, velvet geckos Oedura lesueurii lay eggs communally inside rock crevices. We investigated whether increases in air temperatures could elevate nest temperatures, and if so, how this could influence hatching phenotypes, survival, and population dynamics. In natural nests, maximum daily air temperature influenced mean and maximum daily nest temperatures, implying that nest temperatures will increase under climate warming. To determine whether hotter nests influence hatchling phenotypes, we incubated eggs under two fluctuating temperature regimes to mimic current 'cold' nests (mean = 23.2 °C, range 10-33 °C) and future 'hot' nests (27.0 °C, 14-37 °C). 'Hot' incubation temperatures produced smaller hatchlings than did cold temperature incubation. We released individually marked hatchlings into the wild in 2014 and 2015, and monitored their survival over 10 months. In 2014 and 2015, hot-incubated hatchlings had higher annual mortality (99%, 97%) than cold-incubated (11%, 58%) or wild-born hatchlings (78%, 22%). To determine future trajectories of velvet gecko populations under climate warming, we ran population viability analyses in Vortex and varied annual rates of hatchling mortality within the range 78- 96%. Hatchling mortality strongly influenced the probability of extinction and the mean time to extinction. When hatchling mortality was >86%, populations had a higher probability of extinction (PE: range 0.52- 1.0) with mean times to extinction of 18-44 years. Whether future changes in hatchling survival translate into reduced population viability will depend on the ability of females to modify their nest-site choices. Over the period 1992-2015, females used the same communal nests annually, suggesting that there may be little plasticity in maternal nest-site selection. The impacts of climate change may

  6. Effects of moderate and heavy endurance exercise on nocturnal HRV.

    Science.gov (United States)

    Hynynen, E; Vesterinen, V; Rusko, H; Nummela, A

    2010-06-01

    This study examined the effects of endurance exercise on nocturnal autonomic modulation. Nocturnal R-R intervals were collected after a rest day, after a moderate endurance exercise and after a marathon run in ten healthy, physically active men. Heart rate variability (HRV) was analyzed as a continuous four-hour period starting 30 min after going to bed for sleep. In relation to average nocturnal heart rate after rest day, increases to 109+/-6% and 130+/-11% of baseline were found after moderate endurance exercise and marathon, respectively. Standard deviation of R-R intervals decreased to 90+/-9% and 64+/-10%, root-mean-square of differences between adjacent R-R intervals to 87+/-10% and 55+/-16%, and high frequency power to 77+/-19% and 34+/-19% of baseline after moderate endurance exercise and marathon, respectively. Also nocturnal low frequency power decreased to 56+/-26% of baseline after the marathon. Changes in nocturnal heart rate and HRV suggest prolonged dose-response effects on autonomic modulation after exercises, which may give useful information on the extent of exercise-induced nocturnal autonomic modulation and disturbance to the homeostasis.

  7. Daily Cycle of Air Temperature and Surface Temperature in Stone Forest

    Science.gov (United States)

    Wang, K.; Li, Y.; Wang, X.; Yuan, M.

    2013-12-01

    Urbanization is one of the most profound human activities that impact on climate change. In cities, where are highly artificial areas, the conflict between human activity and natural climate is particularly prominent. Urban areas always have the larger area of impervious land, the higher consumption of greenhouse gases, more emissions of anthropogenic heat and air pollution, all contribute to the urban warming phenomena. Understanding the mechanisms causing a variety of phenomena involved in the urban warming is critical to distinguish the anthropogenic effect and natural variation in the climate change. However, the exact dynamics of urban warming were poorly understood, and effective control strategies are not available. Here we present a study of the daily cycle of air temperature and surface temperature in Stone Forest. The specific heat of the stones in the Stone Forest and concrete of the man-made structures within the cities are approximate. Besides, the height of the Stone Forest and the height of buildings within the city are also similar. As a scenic area, the Stone Forest is being preserved and only opened for sightseeing. There is no anthropogenic heat, as well air pollution within the Stone Forest. The thermal environment in Stone Forest can be considered to be a simulation of thermal environment in the city, which can reveal the effect of man-made structures on urban thermal environment. We conducted the field studies and numerical analysis in the Stone Forest for 4 typical urban morphology and environment scenarios, including high-rise compact cities, low-rise sparse cities, garden cities and isolated single stone. Air temperature and relative humidity were measured every half an hour in 15 different locations, which within different spatial distribution of stones and can represent the four urban scenarios respectively. At the same time, an infrared camera was used to take thermal images and get the hourly surface temperatures of stones and

  8. Effects of Ambient Temperature and Forced-air Warming on Intraoperative Core Temperature: A Factorial Randomized Trial.

    Science.gov (United States)

    Pei, Lijian; Huang, Yuguang; Xu, Yiyao; Zheng, Yongchang; Sang, Xinting; Zhou, Xiaoyun; Li, Shanqing; Mao, Guangmei; Mascha, Edward J; Sessler, Daniel I

    2018-05-01

    The effect of ambient temperature, with and without active warming, on intraoperative core temperature remains poorly characterized. The authors determined the effect of ambient temperature on core temperature changes with and without forced-air warming. In this unblinded three-by-two factorial trial, 292 adults were randomized to ambient temperatures 19°, 21°, or 23°C, and to passive insulation or forced-air warming. The primary outcome was core temperature change between 1 and 3 h after induction. Linear mixed-effects models assessed the effects of ambient temperature, warming method, and their interaction. A 1°C increase in ambient temperature attenuated the negative slope of core temperature change 1 to 3 h after anesthesia induction by 0.03 (98.3% CI, 0.01 to 0.06) °Ccore/(h°Cambient) (P ambient temperature with passive insulation, but was unaffected by ambient temperature during forced-air warming (0.02 [98.3% CI, -0.04 to 0.09] °Ccore/°Cambient; P = 0.40). After an average of 3.4 h of surgery, core temperature was 36.3° ± 0.5°C in each of the forced-air groups, and ranged from 35.6° to 36.1°C in passively insulated patients. Ambient intraoperative temperature has a negligible effect on core temperature when patients are warmed with forced air. The effect is larger when patients are passively insulated, but the magnitude remains small. Ambient temperature can thus be set to comfortable levels for staff in patients who are actively warmed.

  9. Control of the outlet air temperature in an air handling unit

    DEFF Research Database (Denmark)

    Brath, P.; Rasmussen, Henrik; Hägglund, T.

    1998-01-01

    This paper discuss modeling and control of the inlet temperature in an Air Handling Unit, AHU. The model is based on step response experiments made at a full scale test plant. We use gain scheduling to lower the correlation of the air flow with the process dynamic which simplify the control task...

  10. The EUSTACE project: delivering global, daily information on surface air temperature

    Science.gov (United States)

    Ghent, D.; Rayner, N. A.

    2017-12-01

    Day-to-day variations in surface air temperature affect society in many ways; however, daily surface air temperature measurements are not available everywhere. A global daily analysis cannot be achieved with measurements made in situ alone, so incorporation of satellite retrievals is needed. To achieve this, in the EUSTACE project (2015-2018, https://www.eustaceproject.eu) we have developed an understanding of the relationships between traditional (land and marine) surface air temperature measurements and retrievals of surface skin temperature from satellite measurements, i.e. Land Surface Temperature, Ice Surface Temperature, Sea Surface Temperature and Lake Surface Water Temperature. Here we discuss the science needed to produce a fully-global daily analysis (or ensemble of analyses) of surface air temperature on the centennial scale, integrating different ground-based and satellite-borne data types. Information contained in the satellite retrievals is used to create globally-complete fields in the past, using statistical models of how surface air temperature varies in a connected way from place to place. This includes developing new "Big Data" analysis methods as the data volumes involved are considerable. We will present recent progress along this road in the EUSTACE project, i.e.: • identifying inhomogeneities in daily surface air temperature measurement series from weather stations and correcting for these over Europe; • estimating surface air temperature over all surfaces of Earth from surface skin temperature retrievals; • using new statistical techniques to provide information on higher spatial and temporal scales than currently available, making optimum use of information in data-rich eras. Information will also be given on how interested users can become involved.

  11. Can air temperature be used to project influences of climate change on stream temperature?

    Science.gov (United States)

    Arismendi, Ivan; Safeeq, Mohammad; Dunham, Jason B.; Johnson, Sherri L.

    2014-01-01

    Worldwide, lack of data on stream temperature has motivated the use of regression-based statistical models to predict stream temperatures based on more widely available data on air temperatures. Such models have been widely applied to project responses of stream temperatures under climate change, but the performance of these models has not been fully evaluated. To address this knowledge gap, we examined the performance of two widely used linear and nonlinear regression models that predict stream temperatures based on air temperatures. We evaluated model performance and temporal stability of model parameters in a suite of regulated and unregulated streams with 11–44 years of stream temperature data. Although such models may have validity when predicting stream temperatures within the span of time that corresponds to the data used to develop them, model predictions did not transfer well to other time periods. Validation of model predictions of most recent stream temperatures, based on air temperature–stream temperature relationships from previous time periods often showed poor performance when compared with observed stream temperatures. Overall, model predictions were less robust in regulated streams and they frequently failed in detecting the coldest and warmest temperatures within all sites. In many cases, the magnitude of errors in these predictions falls within a range that equals or exceeds the magnitude of future projections of climate-related changes in stream temperatures reported for the region we studied (between 0.5 and 3.0 °C by 2080). The limited ability of regression-based statistical models to accurately project stream temperatures over time likely stems from the fact that underlying processes at play, namely the heat budgets of air and water, are distinctive in each medium and vary among localities and through time.

  12. Nocturnal to Diurnal Switches with Spontaneous Suppression of Wheel-Running Behavior in a Subterranean Rodent.

    Directory of Open Access Journals (Sweden)

    Patricia Tachinardi

    Full Text Available Several rodent species that are diurnal in the field become nocturnal in the lab. It has been suggested that the use of running-wheels in the lab might contribute to this timing switch. This proposition is based on studies that indicate feed-back of vigorous wheel-running on the period and phase of circadian clocks that time daily activity rhythms. Tuco-tucos (Ctenomys aff. knighti are subterranean rodents that are diurnal in the field but are robustly nocturnal in laboratory, with or without access to running wheels. We assessed their energy metabolism by continuously and simultaneously monitoring rates of oxygen consumption, body temperature, general motor and wheel running activity for several days in the presence and absence of wheels. Surprisingly, some individuals spontaneously suppressed running-wheel activity and switched to diurnality in the respirometry chamber, whereas the remaining animals continued to be nocturnal even after wheel removal. This is the first report of timing switches that occur with spontaneous wheel-running suppression and which are not replicated by removal of the wheel.

  13. Nocturnal to Diurnal Switches with Spontaneous Suppression of Wheel-Running Behavior in a Subterranean Rodent

    Science.gov (United States)

    Tachinardi, Patricia; Tøien, Øivind; Valentinuzzi, Veronica S.; Buck, C. Loren; Oda, Gisele A.

    2015-01-01

    Several rodent species that are diurnal in the field become nocturnal in the lab. It has been suggested that the use of running-wheels in the lab might contribute to this timing switch. This proposition is based on studies that indicate feed-back of vigorous wheel-running on the period and phase of circadian clocks that time daily activity rhythms. Tuco-tucos (Ctenomys aff. knighti) are subterranean rodents that are diurnal in the field but are robustly nocturnal in laboratory, with or without access to running wheels. We assessed their energy metabolism by continuously and simultaneously monitoring rates of oxygen consumption, body temperature, general motor and wheel running activity for several days in the presence and absence of wheels. Surprisingly, some individuals spontaneously suppressed running-wheel activity and switched to diurnality in the respirometry chamber, whereas the remaining animals continued to be nocturnal even after wheel removal. This is the first report of timing switches that occur with spontaneous wheel-running suppression and which are not replicated by removal of the wheel. PMID:26460828

  14. Nitrogen Oxides in the Nocturnal Boundary Layer: Chemistry of Nitrous Acid (HONO) and the Nitrate Radical (N03)

    Energy Technology Data Exchange (ETDEWEB)

    Jochen Stutz

    2005-05-24

    dependent. Measurements at one altitude, for example at the ground, where most air quality monitoring stations are located, are not representative for the rest of the NBL. Our model also revealed that radical chemistry is, in general, altitude dependent at night. We distinguish three regions: an unreactive, NO rich, ground layer; an upper, O3 and NO3 dominated layer, and a reactive mixing layer, where RO2 radicals are mixed from aloft with NO from the ground. In this reactive layer an active radical chemistry and elevated OH radical levels can be found. The downward transport of N2O5 and HO2NO2, followed by their thermal decay, was also identified as a radical source in this layer. Our observations also gave insight into the formation of HONO in the NBL. Based on our field experiments we were able to show that the NO2 to HONO conversion was relative humidity dependent. While this fact was well known, we found that it is most likely the uptake of HONO onto surfaces which is R.H. dependent, rather than the NO2 to HONO conversion. This finding led to the proposal of a new NO2 to HONO conversion mechanism, which is based on solid physical chemical principles. Noteworthy is also the observation of enhanced NO2 to HONO conversion during a dust storm event in Phoenix. The final activity in our project investigated the influence of the urban canopy, i.e. building walls and surfaces, on nocturnal chemistry. For the first time the surface area of a city was determined based on a Geographical Information System database of the city of Santa Monica. The surface to volume areas found in this study showed that, in the 2 lower part of the NBL, buildings provide a much larger surface area than the aerosol. In addition, buildings take up a considerable amount of the volume near the ground. The expansion of our model and sensitivity studies based on the Santa Monica data revealed that the surface area of buildings considerably influences HONO levels in urban areas. The volume reduction leads

  15. Paroxysmal nocturnal hemoglobinuria (PNH)

    Science.gov (United States)

    ... help slow the breakdown of red blood cells. Blood transfusions may be needed. Supplemental iron and folic acid ... is no known way to prevent this disorder. Alternative Names PNH Images Blood cells References Brodsky RA. Proxymal nocturnal hemoglobinuria. In: ...

  16. Thermodynamic diagrams for high temperature plasmas of air, air-carbon, carbon-hydrogen mixtures, and argon

    CERN Document Server

    Kroepelin, H; Hoffmann, K-U

    2013-01-01

    Thermodynamic Diagrams for High Temperature Plasmas of Air, Air-Carbon, Carbon-Hydrogen Mixtures, and Argon provides information relating to the properties of equilibrium gas plasmas formed from hydrocarbons, from air without argon, from pure argon, and from mixtures of air and carbon at various compositions, temperatures and pressures. The data are presented in graphical rather than tabular form to provide a clearer picture of the plasma processes investigated. This book is composed of four chapters, and begins with the introduction to the characteristics of plasmas, with emphasis on their th

  17. Nocturnal vision and landmark orientation in a tropical halictid bee.

    Science.gov (United States)

    Warrant, Eric J; Kelber, Almut; Gislén, Anna; Greiner, Birgit; Ribi, Willi; Wcislo, William T

    2004-08-10

    Some bees and wasps have evolved nocturnal behavior, presumably to exploit night-flowering plants or avoid predators. Like their day-active relatives, they have apposition compound eyes, a design usually found in diurnal insects. The insensitive optics of apposition eyes are not well suited for nocturnal vision. How well then do nocturnal bees and wasps see? What optical and neural adaptations have they evolved for nocturnal vision? We studied female tropical nocturnal sweat bees (Megalopta genalis) and discovered that they are able to learn landmarks around their nest entrance prior to nocturnal foraging trips and to use them to locate the nest upon return. The morphology and optics of the eye, and the physiological properties of the photoreceptors, have evolved to give Megalopta's eyes almost 30 times greater sensitivity to light than the eyes of diurnal worker honeybees, but this alone does not explain their nocturnal visual behavior. This implies that sensitivity is improved by a strategy of photon summation in time and in space, the latter of which requires the presence of specialized cells that laterally connect ommatidia into groups. First-order interneurons, with significantly wider lateral branching than those found in diurnal bees, have been identified in the first optic ganglion (the lamina ganglionaris) of Megalopta's optic lobe. We believe that these cells have the potential to mediate spatial summation. Despite the scarcity of photons, Megalopta is able to visually orient to landmarks at night in a dark forest understory, an ability permitted by unusually sensitive apposition eyes and neural photon summation.

  18. Impact of air pollution and temperature on adverse birth outcomes: Madrid, 2001-2009.

    Science.gov (United States)

    Arroyo, Virginia; Díaz, Julio; Carmona, Rocío; Ortiz, Cristina; Linares, Cristina

    2016-11-01

    Low birth weight (<2500 g) (LBW), premature birth (<37 weeks of gestation) (PB), and late foetal death (<24 h of life) (LFD) are causes of perinatal morbi-mortality, with short- and long-term social and economic health impacts. This study sought to identify gestational windows of susceptibility during pregnancy and to analyse and quantify the impact of different air pollutants, noise and temperature on the adverse birth outcomes. Time-series study to assess the impact of mean daily PM 2.5 , NO 2 and O 3 (μg/m 3 ), mean daily diurnal (Leqd) and nocturnal (Leqn) noise levels (dB(A)), maximum and minimum daily temperatures (°C) on the number of births with LBW, PB or LFD in Madrid across the period 2001-2009. We controlled for linear trend, seasonality and autoregression. Poisson regression models were fitted for quantification of the results. The final models were expressed as relative risk (RR) and population attributable risk (PAR). Leqd was observed to have the following impacts in LBW: at onset of gestation, in the second trimester and in the week of birth itself. NO 2 had an impact in the second trimester. In the case of PB, the following: Leqd in the second trimester, Leqn in the week before birth and PM 2.5 in the second trimester. In the case of LFD, impacts were observed for both PM 2.5 in the third trimester, and minimum temperature. O 3 proved significant in the first trimester for LBW and PB, and in the second trimester for LFD. Pollutants concentrations, noise and temperature influenced the weekly average of new-borns with LBW, PB and LFD in Madrid. Special note should be taken of the effect of diurnal noise on LBW across the entire pregnancy. The exposure of pregnant population to the environmental factors analysed should therefore be controlled with a view to reducing perinatal morbi-mortality. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Temporal Relationships Between Napping and Nocturnal Sleep in Healthy Adolescents.

    Science.gov (United States)

    Jakubowski, Karen P; Hall, Martica H; Lee, Laisze; Matthews, Karen A

    2017-01-01

    Many adolescents do not achieve the recommended 9 hr of sleep per night and report daytime napping, perhaps because it makes up for short nocturnal sleep. This article tests temporal relationships between daytime naps and nighttime sleep as measured by actigraphy and diary among 236 healthy high school students during one school week. Mixed model analyses adjusted for age, race, and gender demonstrated that shorter actigraphy-assessed nocturnal sleep duration predicted longer napping (measured by actigraphy and diary) the next day. Napping (by actigraphy and diary) predicted shorter nocturnal sleep duration and worse sleep efficiency that night measured by actigraphy. Diary-reported napping also predicted poorer self-reported sleep quality that night. Frequent napping may interfere with nocturnal sleep during adolescence.

  20. Two-way effect modifications of air pollution and air temperature on total natural and cardiovascular mortality in eight European urban areas.

    Science.gov (United States)

    Chen, Kai; Wolf, Kathrin; Breitner, Susanne; Gasparrini, Antonio; Stafoggia, Massimo; Samoli, Evangelia; Andersen, Zorana Jovanovic; Bero-Bedada, Getahun; Bellander, Tom; Hennig, Frauke; Jacquemin, Bénédicte; Pekkanen, Juha; Hampel, Regina; Cyrys, Josef; Peters, Annette; Schneider, Alexandra

    2018-07-01

    Although epidemiological studies have reported associations between mortality and both ambient air pollution and air temperature, it remains uncertain whether the mortality effects of air pollution are modified by temperature and vice versa. Moreover, little is known on the interactions between ultrafine particles (diameter ≤ 100 nm, UFP) and temperature. We investigated whether the short-term associations of particle number concentration (PNC in the ultrafine range (≤100 nm) or total PNC ≤ 3000 nm, as a proxy for UFP), particulate matter ≤ 2.5 μm (PM 2.5 ) and ≤ 10 μm (PM 10 ), and ozone with daily total natural and cardiovascular mortality were modified by air temperature and whether air pollution levels affected the temperature-mortality associations in eight European urban areas during 1999-2013. We first analyzed air temperature-stratified associations between air pollution and total natural (nonaccidental) and cardiovascular mortality as well as air pollution-stratified temperature-mortality associations using city-specific over-dispersed Poisson additive models with a distributed lag nonlinear temperature term in each city. All models were adjusted for long-term and seasonal trend, day of the week, influenza epidemics, and population dynamics due to summer vacation and holidays. City-specific effect estimates were then pooled using random-effects meta-analysis. Pooled associations between air pollutants and total and cardiovascular mortality were overall positive and generally stronger at high relatively compared to low air temperatures. For example, on days with high air temperatures (>75th percentile), an increase of 10,000 particles/cm 3 in PNC corresponded to a 2.51% (95% CI: 0.39%, 4.67%) increase in cardiovascular mortality, which was significantly higher than that on days with low air temperatures (air pollution (>50th percentile), both heat- and cold-related mortality risks increased. Our findings showed that

  1. Differences in ocular parameters between diurnal and nocturnal raptors.

    Science.gov (United States)

    Beckwith-Cohen, Billie; Horowitz, Igal; Bdolah-Abram, Tali; Lublin, Avishai; Ofri, Ron

    2015-01-01

    To establish and compare normal ocular parameters between and within diurnal and nocturnal raptor groups. Eighty-eight ophthalmically normal raptors of six nocturnal and 11 diurnal species were studied. Tear production was measured using Schirmer tear test (STT) and phenol red thread test (PRTT), and applanation tonometry was conducted. Ultrasonographic measurements of axial length (AL), mediolateral axis (ML), vitreous body (VB), and pecten length (PL) were recorded, and conjunctival cultures were obtained. A weak correlation (R = 0.312, P = 0.006) was found between PRTT and STT. Tear production was significantly lower in nocturnal species (P raptors were positive for mycology or bacteriology, either on culture or PCR. The most common infectious agent isolated was Staphylococcus spp. Phenol red thread test and STT are both valid methods to measure tear production; however, a separate baseline must be determined for each species using these methods, as the results of one method cannot be extrapolated to the other. Due to significant differences observed within diurnal and nocturnal species, it appears that a more intricate division should be used when comparing these parameters for raptors, and the classification of diurnal or nocturnal holds little significance in the baseline of these data. © 2013 American College of Veterinary Ophthalmologists.

  2. Crowdsourcing urban air temperature measurements using smartphones

    Science.gov (United States)

    Balcerak, Ernie

    2013-10-01

    Crowdsourced data from cell phone battery temperature sensors could be used to contribute to improved real-time, high-resolution air temperature estimates in urban areas, a new study shows. Temperature observations in cities are in some cases currently limited to a few weather stations, but there are millions of smartphone users in many cities. The batteries in cell phones have temperature sensors to avoid damage to the phone.

  3. Nocturnal Hypertension: Neglected Issue in Comprehensive Hypertension Management

    Directory of Open Access Journals (Sweden)

    Andi Kristanto

    2016-09-01

    Full Text Available The body circardian rhythm affects blood pressure variability at day and night, therefore blood pressure at day and night might be different. Nocturnal hypertension is defined as increase of blood pressure >120/70mmHg at night, which is caused by disturbed circadian rhythm, and associated with higher cardiovascular and cerebrovascular events also mortality in hypertensive patients. Nocturnal hypertension and declining blood pressure pattern, can only be detected by continuous examination for 24 hours, also known as ambulatory blood pressure measurement (ABPM. Chronotherapy, has become a strategy for managing the hypertensive nocturnal patients, by taking hypertensive medication at night to obtain normal blood pressure decrease in accordance with the normal circadian rhythm and, improving blood pressure control.

  4. Statistical modeling of urban air temperature distributions under different synoptic conditions

    Science.gov (United States)

    Beck, Christoph; Breitner, Susanne; Cyrys, Josef; Hald, Cornelius; Hartz, Uwe; Jacobeit, Jucundus; Richter, Katja; Schneider, Alexandra; Wolf, Kathrin

    2015-04-01

    Within urban areas air temperature may vary distinctly between different locations. These intra-urban air temperature variations partly reach magnitudes that are relevant with respect to human thermal comfort. Therefore and furthermore taking into account potential interrelations with other health related environmental factors (e.g. air quality) it is important to estimate spatial patterns of intra-urban air temperature distributions that may be incorporated into urban planning processes. In this contribution we present an approach to estimate spatial temperature distributions in the urban area of Augsburg (Germany) by means of statistical modeling. At 36 locations in the urban area of Augsburg air temperatures are measured with high temporal resolution (4 min.) since December 2012. These 36 locations represent different typical urban land use characteristics in terms of varying percentage coverages of different land cover categories (e.g. impervious, built-up, vegetated). Percentage coverages of these land cover categories have been extracted from different sources (Open Street Map, European Urban Atlas, Urban Morphological Zones) for regular grids of varying size (50, 100, 200 meter horizonal resolution) for the urban area of Augsburg. It is well known from numerous studies that land use characteristics have a distinct influence on air temperature and as well other climatic variables at a certain location. Therefore air temperatures at the 36 locations are modeled utilizing land use characteristics (percentage coverages of land cover categories) as predictor variables in Stepwise Multiple Regression models and in Random Forest based model approaches. After model evaluation via cross-validation appropriate statistical models are applied to gridded land use data to derive spatial urban air temperature distributions. Varying models are tested and applied for different seasons and times of the day and also for different synoptic conditions (e.g. clear and calm

  5. An analysis of spatial representativeness of air temperature monitoring stations

    Science.gov (United States)

    Liu, Suhua; Su, Hongbo; Tian, Jing; Wang, Weizhen

    2018-05-01

    Surface air temperature is an essential variable for monitoring the atmosphere, and it is generally acquired at meteorological stations that can provide information about only a small area within an r m radius ( r-neighborhood) of the station, which is called the representable radius. In studies on a local scale, ground-based observations of surface air temperatures obtained from scattered stations are usually interpolated using a variety of methods without ascertaining their effectiveness. Thus, it is necessary to evaluate the spatial representativeness of ground-based observations of surface air temperature before conducting studies on a local scale. The present study used remote sensing data to estimate the spatial distribution of surface air temperature using the advection-energy balance for air temperature (ADEBAT) model. Two target stations in the study area were selected to conduct an analysis of spatial representativeness. The results showed that one station (AWS 7) had a representable radius of about 400 m with a possible error of less than 1 K, while the other station (AWS 16) had the radius of about 250 m. The representable radius was large when the heterogeneity of land cover around the station was small.

  6. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms......The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  7. Survival with Three-Times Weekly In-Center Nocturnal Versus Conventional Hemodialysis

    Science.gov (United States)

    Xu, Jianglin; Suri, Rita S.; Nesrallah, Gihad; Lindsay, Robert; Garg, Amit X.; Lester, Keith; Ofsthun, Norma; Lazarus, Michael; Hakim, Raymond M.

    2012-01-01

    Whether the duration of hemodialysis treatments improves outcomes remains controversial. Here, we evaluated survival and clinical changes associated with converting from conventional hemodialysis (mean=3.75 h/treatment) to in-center nocturnal hemodialysis (mean=7.85 h/treatment). All 959 consecutive patients who initiated nocturnal hemodialysis for the first time in 77 Fresenius Medical Care facilities during 2006 and 2007 were eligible. We used Cox models to compare risk for mortality during 2 years of follow-up in a 1:3 propensity score–matched cohort of 746 nocturnal and 2062 control patients on conventional hemodialysis. Two-year mortality was 19% among nocturnal hemodialysis patients compared with 27% among conventional patients. Nocturnal hemodialysis associated with a 25% reduction in the risk for death after adjustment for age, body mass index, and dialysis vintage (hazard ratio=0.75, 95% confidence interval=0.61–0.91, P=0.004). With respect to clinical features, interdialytic weight gain, albumin, hemoglobin, dialysis dose, and calcium increased on nocturnal therapy, whereas postdialysis weight, predialysis systolic blood pressure, ultrafiltration rate, phosphorus, and white blood cell count declined (all P<0.001). In summary, notwithstanding the possibility of residual selection bias, conversion to treatment with nocturnal hemodialysis associates with favorable clinical features, laboratory biomarkers, and improved survival compared with propensity score–matched controls. The potential impact of extended treatment time on clinical outcomes while maintaining a three times per week hemodialysis schedule requires evaluation in future clinical trials. PMID:22362905

  8. Desmopressin (melt) therapy in children with monosymptomatic nocturnal enuresis and nocturnal polyuria results in improved neuropsychological functioning and sleep.

    Science.gov (United States)

    Van Herzeele, Charlotte; Dhondt, Karlien; Roels, Sanne P; Raes, Ann; Hoebeke, Piet; Groen, Luitzen-Albert; Vande Walle, Johan

    2016-09-01

    There is a high comorbidity between nocturnal enuresis, sleep disorders and psychological problems. The aim of this study was to investigate whether a decrease in nocturnal diuresis volume not only improves enuresis but also ameliorates disrupted sleep and (neuro)psychological dysfunction, the major comorbidities of this disorder. In this open-label, prospective phase IV study, 30 children with monosymptomatic nocturnal enuresis (MNE) underwent standardized video-polysomnographic testing and multi-informant (neuro)psychological testing at baseline and 6 months after the start of desmopressin treatment in the University Hospital Ghent, Belgium. Primary endpoints were the effect on sleep and (neuro)psychological functioning. The secondary endpoint was the change in the first undisturbed sleep period or the time to the first void. Thirty children aged between 6 and 16 (mean 10.43, standard deviation 3.08) years completed the study. The results demonstrated a significant decrease in periodic limb movements during sleep (PLMS) and a prolonged first undisturbed sleep period. Additionally, (neuro)psychological functioning was improved on several domains. The study demonstrates that the degree of comorbidity symptoms is at least aggravated by enuresis (and/or high nocturnal diuresis rate) since sleep and (neuro)psychological functioning were significantly ameliorated by treatment of enuresis. These results indicate that enuresis is not such a benign condition as has previously been assumed.

  9. Estimations of distribution and zoning for air temperature using satellite data over Liaoning province, China

    International Nuclear Information System (INIS)

    Wang, X.; Horiguchi, I.; Takeda, T.; Yazawa, M.; Liu, X.; Yang, Y.; Wang, Q.

    1999-01-01

    The distribution and zoning of air temperature over Liaoning Province, China were examined using the calculated values of air temperature derived from satellite data (GMS data) as well as from altitude data. The results are summarized as follows. At 02:00 LST the correlation coefficients for the air temperatures calculated from altitude compared with the observed air temperatures were the same as those of the air temperatures derived from GMS data. At 14:00 LST, however, the correlation coefficients for air temperatures calculated from altitude were less than those of the air temperatures derived from GMS data. This fact verifies that the distribution of air temperature in the day-time is affected by other factors than altitude. The distribution of air temperature in a cell of approximately 5'(latitude) x 7.5'(longitude) over Liaoning Province, china was estimated by using the regression equations between surface temperature derived from GMS and the observed air temperature. The distribution of air temperature was classified into 5 types, and the types are obtained at 14:00 LST are seasonal ones but the types at 02:00 LST are not related to season. Also, the regional classification for the air temperature was examined using this distribution of air temperature. This regional classification for the air temperature was similar to the published zoning of the agricultural climate. It became clear that the characteristic distribution of air temperature in a cell unit can be obtained by satellite data. And it is possible to define the zoning of air temperature for a cell unit by the accumulated analyses of satellite data over an extended period

  10. Can air-breathing fish be adapted to higher than present temperatures?

    DEFF Research Database (Denmark)

    Bayley, Mark

    Air-breathing in fish is thought to have evolved in environments at lower than present oxygen levels and higher than present temperatures raising the question of whether extant species are adapted to recent temperature regimes or living at sub-optimal temperatures. The air-breathing Pangasionodon...... hypophthalmus inhabits the Mekong river system covering two climate zones during its life cycle and migrating more than 2000 km from hatching in northern Laos to its adult life in the southern delta region. It is a facultative air-breather with well-developed gills and air-breathing organ and an unusual...... circulatory bauplan. Here we examine the question of its optimal temperature through aspects of its cardio respiratory physiology including temperature effects on blood oxygen binding, ventilation and blood gasses, stereological measures of cardiorespiratory system, metabolic rate and growth. Comparing...

  11. [Nocturnal polyuria, treatment with desmopressin].

    Science.gov (United States)

    Zachoval, R; Krhut, J; Šottner, O; Hanuš, T; Martan, A; Horčička, L; Feyereisl, J; Halaška, M; Švabík, K; Krofta, L

    2013-08-01

    Nonpharmacologic and especially pharmacologic treatment options are available for nocturnal polyuria. Desmopressin represents the basis of pharmacologic treatment. Desmopressin acetate is a synthetic analogue of arginine vasopressin with high affinity to V2 receptors with antidiuretic effect. It is the only medicament currently registered for antidiuretic treatment. Desmopressin has not any relevant affinity to V1 receptors, and therefore there is no hypertensive effect in contrary to natural vasopressin. Desmopressin use before a bedtime leads to reduced production of urine during a sleep, therefore time between desires to void is prolonged and number of nocturia is reduced. Clinical effect, in a meaning of reduced urine production and increased osmolality of urine, lasts approximately 8-12 hours. In the treatment of nocturnal polyuria desmopressin is used orally one hour before a bedtime. It is essential to titrate an ideal dose, the initial dose is 60 µg of MELT formula (fast melting oral formulation) and it can be increased according to the clinical effect up to the maximal recommended daily dose 240 µg. Patients treated with desmopressin should cut down a fluid intake 1 hour before and 8 hours after the use of desmopressin. Total number of adverse events connected withdesmopressin treatment in clinical studies was higher compared to placebo but the side effects were mostly mild. The most common adverse events were headaches, nausea, diarrhoea, abdominal pain, dry mouth and hyponatremia both in the short-term and long-term clinical trials. Hyponatremia was observed mainly in patients over 65 year of age. Therefore treatment with desmopressin should not be commended in patients over 65 year of age without close monitoring of the natrium level in serum and all patients should be informed about the first symptoms of hyponatremia - headache, nausea and insomnia. According to Evidence Based Medicine, the level of evidence for treatment of nocturnal polyuria with

  12. Visual reliability and information rate in the retina of a nocturnal bee.

    Science.gov (United States)

    Frederiksen, Rikard; Wcislo, William T; Warrant, Eric J

    2008-03-11

    Nocturnal animals relying on vision typically have eyes that are optically and morphologically adapted for both increased sensitivity and greater information capacity in dim light. Here, we investigate whether adaptations for increased sensitivity also are found in their photoreceptors by using closely related and fast-flying nocturnal and diurnal bees as model animals. The nocturnal bee Megalopta genalis is capable of foraging and homing by using visually discriminated landmarks at starlight intensities. Megalopta's near relative, Lasioglossum leucozonium, performs these tasks only in bright sunshine. By recording intracellular responses to Gaussian white-noise stimuli, we show that photoreceptors in Megalopta actually code less information at most light levels than those in Lasioglossum. However, as in several other nocturnal arthropods, Megalopta's photoreceptors possess a much greater gain of transduction, indicating that nocturnal photoreceptors trade information capacity for sensitivity. By sacrificing photoreceptor signal-to-noise ratio and information capacity in dim light for an increased gain and, thus, an increased sensitivity, this strategy can benefit nocturnal insects that use neural summation to improve visual reliability at night.

  13. Aviary heating: control of air temperature heated by a set biomass gasifier-combustor in a co-current flow, using a frequency inverter; Aquecimento de aviarios: controle da temperatura do ar aquecido por um conjunto gaseificador-combustor de biomassa de fluxo concorrente, utilizando um inversor de frequencia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, William Rosario dos [Universidade Presidente Antonio Carlos (UNIPAC), Ponte Nova, MG (Brazil); Silva, Jadir Nogueira; Oliveira Filho, Delly; Martins, Marcio Aredes; Oliveira, Jofran Luiz de [Universidade Federal de Vicosa (UFV), MG (Brazil)], Emails: jadir@ufv.br, delly@ufv.br, aredes@ufv.br, jofran.oliveira@ufv.br

    2009-07-01

    One of the problems with using the gasifier for heating purposes in poultry facilities is the waste of energy during the day, once the equipment does not have control of the thermal and power generated. During this period, the difference in temperature between the air and the standard for the birds inside the building is lower than when compared with the nocturnal period. During the day, the temperature inside the poultry house is controlled by curtains, which occurs without diminishing the biomass burning. Another way to control the temperature is the shutdown of the system, which requires the constant attention of the operator. In this way, there is a potential for energy savings if the thermal power could be controlled according to the demand, which can be represented by the temperature gradient. The purpose of this study was to control the temperature of exhaustion air from a set combustor-gasifier (down draft), based on the model developed by Martin et al. (2006), through the control of speed of the fan engine and also controlling the flow contributions of primary and secondary air in the combustor. The experiment was carried out in the Energy and Pre-processing of Agricultural Products areas, at the Department of Agricultural Engineering - Federal University of Vicosa. (author)

  14. High-precision diode-laser-based temperature measurement for air refractive index compensation

    International Nuclear Information System (INIS)

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppae, Jeremias; Lassila, Antti

    2011-01-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlen equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

  15. 40 CFR 1065.670 - NOX intake-air humidity and temperature corrections.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false NOX intake-air humidity and... NOX intake-air humidity and temperature corrections. See the standard-setting part to determine if you may correct NOX emissions for the effects of intake-air humidity or temperature. Use the NOX intake...

  16. Urban Climate and Air Pollution in Ouagadougou, Burkina Faso

    Energy Technology Data Exchange (ETDEWEB)

    Linden, Jenny

    2011-05-15

    Africa has recently been singled out by UN Habitat as the fastest urbanizing continent in the world. The most extreme case was found in the Sahelian city of Ouagadougou, Burkina Faso, where the population is expected to almost double over the next ten years. It is well known that the rapid growth of an urban area is among the most important anthropogenic impacts on the environment, and that it has a profound impact on both the urban climate and air quality. Few studies have been focused on cities in the Sahel region, and the lack of information may consequently hinder adaptation to the extreme urbanization rates of these often heavily polluted cities. The main objective of this thesis was to study the nature of, and relationship between, urban climate and air pollution in Ouagadougou, Burkina Faso. Specific objectives were to; examine spatial variations in daily temperature and humidity patterns during early dry season with focus on effects of different land cover; to examine the influence of atmospheric stability on the intra-urban air temperature patterns, the urban wind field and on air pollution levels; and to examine spatial variations in air pollution levels. An additional objective was to document the status and potential development of synoptic meteorological stations in Burkina Faso. Empirical data used in analyses were collected during five field studies between 2003 and 2010. Meteorological and air pollution parameters were measured at fixed sites and through car traverses in areas of different land cover, activity, traffic density and road surface. The most distinct features in thermal patterns found in Ouagadougou were strong intra-urban nocturnal cool islands in vegetated areas, caused by evening evaporative cooling by the vegetation. Extremely stable nocturnal atmospheric conditions were observed during 80 % of days examined in early dry season, during which spatial patterns in temperature and humidity as well as in air pollution were most pronounced

  17. Low levels of nitryl chloride at ground level: nocturnal nitrogen oxides in the Lower Fraser Valley of British Columbia

    Directory of Open Access Journals (Sweden)

    H. D. Osthoff

    2018-05-01

    Full Text Available The nocturnal nitrogen oxides, which include the nitrate radical (NO3, dinitrogen pentoxide (N2O5, and its uptake product on chloride containing aerosol, nitryl chloride (ClNO2, can have profound impacts on the lifetime of NOx ( =  NO + NO2, radical budgets, and next-day photochemical ozone (O3 production, yet their abundances and chemistry are only sparsely constrained by ambient air measurements.Here, we present a measurement data set collected at a routine monitoring site near the Abbotsford International Airport (YXX located approximately 30 km from the Pacific Ocean in the Lower Fraser Valley (LFV on the west coast of British Columbia. Measurements were made from 20 July to 4 August 2012 and included mixing ratios of ClNO2, N2O5, NO, NO2, total odd nitrogen (NOy, O3, photolysis frequencies, and size distribution and composition of non-refractory submicron aerosol (PM1.At night, O3 was rapidly and often completely removed by dry deposition and by titration with NO of anthropogenic origin and unsaturated biogenic hydrocarbons in a shallow nocturnal inversion surface layer. The low nocturnal O3 mixing ratios and presence of strong chemical sinks for NO3 limited the extent of nocturnal nitrogen oxide chemistry at ground level. Consequently, mixing ratios of N2O5 and ClNO2 were low ( <  30 and  <  100 parts-per-trillion by volume (pptv and median nocturnal peak values of 7.8 and 7.9 pptv, respectively. Mixing ratios of ClNO2 frequently peaked 1–2 h after sunrise rationalized by more efficient formation of ClNO2 in the nocturnal residual layer aloft than at the surface and the breakup of the nocturnal boundary layer structure in the morning. When quantifiable, production of ClNO2 from N2O5 was efficient and likely occurred predominantly on unquantified supermicron-sized or refractory sea-salt-derived aerosol. After sunrise, production of Cl radicals from photolysis of ClNO2 was negligible compared to production of OH

  18. Does petroleum development affect burrowing owl nocturnal space-use?

    Energy Technology Data Exchange (ETDEWEB)

    Scobie, Corey; Wellicome, Troy; Bayne, Erin [Department of Biological Sciences, University of Alberta (Canada)], email: cscobie@ualberta.ca, email: tiw@ualberta.ca, email: bayne@ualberta.ca

    2011-07-01

    Decline all over Canada in the population of burrowing owls, a federally listed endangered species, has raised concerns about the possible influence of petroleum infrastructure development on owl nocturnal space-use while foraging. Roads, wells, pipelines and sound-producing facilities related to petroleum development change the landscape and can influence the owls' mortality risk. For 3 years, 27 breeding adult male burrowing owls with nests close to different petroleum infrastructures were captured and fitted with a miniature GPS datalogger in order to track their nocturnal foraging. Data from these GPS devices were fed into a geographical information system and showed that pipelines and wells did not alter the foraging habits of the owls. Dirt and gravel roads, with little traffic, were preferentially selected by the owls, conceivably because of higher owl mortality risk along paved roads. Sound-producing facilities did not change owls' foraging behaviour, implying that sound may not affect their nocturnal space-use. Traffic data and sound power measurements will be used in further studies in an effort to better understand burrowing owls' nocturnal foraging habits.

  19. Change in air temperature over Sudan and South Sudan with time ...

    African Journals Online (AJOL)

    Annual mean air temperature for Sudan and South Sudan for the three periods 1900-1940, 1961- 1990 and 1981-2010 for 12 stations was analyzed with objectives of studying changes in air temperature over the area during the last century and also to study the linkages between mean, maximum and minimum air ...

  20. Numerical Analysis of Exergy for Air-Conditioning Influenced by Ambient Temperature

    Directory of Open Access Journals (Sweden)

    Jing-Nang Lee

    2014-07-01

    Full Text Available The article presents numerical analysis of exergy for air-conditioning influenced by ambient temperature. The model of numerical simulation uses an integrated air conditioning system exposed in varied ambient temperature to observe change of the four main devices, the compressor, the condenser, the capillary, and the evaporator in correspondence to ambient temperature. The analysis devices of the four devices’s exergy influenced by the varied ambient temperature and found that the capillary has unusual increasing exergy loss vs. increasing ambient temperature in comparison to the other devices. The result shows that reducing exergy loss of the capillary influenced by the ambient temperature is the key for improving working efficiency of an air-conditioning system when influence of the ambient temperature is considered. The higher ambient temperature causes the larger pressure drop of capillary and more exergy loss.

  1. Apparatus and method for maintaining an article at a temperature that is less than the temperature of the ambient air

    Science.gov (United States)

    Klett, James; Klett, Lynn

    2018-04-03

    An apparatus for maintaining the temperature of an article at a temperature that is below the ambient air temperature includes an enclosure having an outer wall that defines an interior chamber for holding a volume of sealed air. An insert is disposed inside of the chamber and has a body that is made of a porous graphite foam material. A vacuum pump penetrates the outer wall and fluidly connects the sealed air in the interior chamber with the ambient air outside of the enclosure. The temperatures of the insert and article is maintained at temperatures that are below the ambient air temperature when a volume of a liquid is wicked into the pores of the porous insert and the vacuum pump is activated to reduce the pressure of a volume of sealed air within the interior chamber to a pressure that is below the vapor pressure of the liquid.

  2. Low levels of nitryl chloride at ground level: nocturnal nitrogen oxides in the Lower Fraser Valley of British Columbia

    Science.gov (United States)

    Osthoff, Hans D.; Odame-Ankrah, Charles A.; Taha, Youssef M.; Tokarek, Travis W.; Schiller, Corinne L.; Haga, Donna; Jones, Keith; Vingarzan, Roxanne

    2018-05-01

    The nocturnal nitrogen oxides, which include the nitrate radical (NO3), dinitrogen pentoxide (N2O5), and its uptake product on chloride containing aerosol, nitryl chloride (ClNO2), can have profound impacts on the lifetime of NOx ( = NO + NO2), radical budgets, and next-day photochemical ozone (O3) production, yet their abundances and chemistry are only sparsely constrained by ambient air measurements. Here, we present a measurement data set collected at a routine monitoring site near the Abbotsford International Airport (YXX) located approximately 30 km from the Pacific Ocean in the Lower Fraser Valley (LFV) on the west coast of British Columbia. Measurements were made from 20 July to 4 August 2012 and included mixing ratios of ClNO2, N2O5, NO, NO2, total odd nitrogen (NOy), O3, photolysis frequencies, and size distribution and composition of non-refractory submicron aerosol (PM1). At night, O3 was rapidly and often completely removed by dry deposition and by titration with NO of anthropogenic origin and unsaturated biogenic hydrocarbons in a shallow nocturnal inversion surface layer. The low nocturnal O3 mixing ratios and presence of strong chemical sinks for NO3 limited the extent of nocturnal nitrogen oxide chemistry at ground level. Consequently, mixing ratios of N2O5 and ClNO2 were low ( formation of ClNO2 in the nocturnal residual layer aloft than at the surface and the breakup of the nocturnal boundary layer structure in the morning. When quantifiable, production of ClNO2 from N2O5 was efficient and likely occurred predominantly on unquantified supermicron-sized or refractory sea-salt-derived aerosol. After sunrise, production of Cl radicals from photolysis of ClNO2 was negligible compared to production of OH from the reaction of O(1D) + H2O except for a short period after sunrise.

  3. Impacts of Lowered Urban Air Temperatures on Precursor Emission and Ozone Air Quality.

    Science.gov (United States)

    Taha, Haider; Konopacki, Steven; Akbari, Hashem

    1998-09-01

    Meteorological, photochemical, building-energy, and power plant simulations were performed to assess the possible precursor emission and ozone air quality impacts of decreased air temperatures that could result from implementing the "cool communities" concept in California's South Coast Air Basin (SoCAB). Two pathways are considered. In the direct pathway, a reduction in cooling energy use translates into reduced demand for generation capacity and, thus, reduced precursor emissions from electric utility power plants. In the indirect pathway, reduced air temperatures can slow the atmospheric production of ozone as well as precursor emission from anthropogenic and biogenic sources. The simulations suggest small impacts on emissions following implementation of cool communities in the SoCAB. In summer, for example, there can be reductions of up to 3% in NO x emissions from in-basin power plants. The photochemical simulations suggest that the air quality impacts of these direct emission reductions are small. However, the indirect atmospheric effects of cool communities can be significant. For example, ozone peak concentrations can decrease by up to 11% in summer and population-weighted exceedance exposure to ozone above the California and National Ambient Air Quality Standards can decrease by up to 11 and 17%, respectively. The modeling suggests that if these strategies are combined with others, such as mobile-source emission control, the improvements in ozone air quality can be substantial.

  4. Characterizing Air Temperature Changes in the Tarim Basin over 1960–2012

    Science.gov (United States)

    Peng, Dongmei; Wang, Xiujun; Zhao, Chenyi; Wu, Xingren; Jiang, Fengqing; Chen, Pengxiang

    2014-01-01

    There has been evidence of warming rate varying largely over space and between seasons. However, little has been done to evaluate the spatial and temporal variability of air temperature in the Tarim Basin, northwest China. In this study, we collected daily air temperature from 19 meteorological stations for the period of 1960–2012, and analyzed annual mean temperature (AMT), the annual minimum (Tmin) and maximum temperature (Tmax), and mean temperatures of all twelve months and four seasons and their anomalies. Trend analyses, standard deviation of the detrended anomaly (SDDA) and correlations were carried out to characterize the spatial and temporal variability of various mean air temperatures. Our data showed that increasing trend was much greater in the Tmin (0.55°C/10a) than in the AMT (0.25°C/10a) and Tmax (0.12°C/10a), and the fluctuation followed the same order. There were large spatial variations in the increasing trends of both AMT (from −0.09 to 0.43 °C/10a) and Tmin (from 0.15 to 1.12°C/10a). Correlation analyses indicated that AMT had a significantly linear relationship with Tmin and the mean temperatures of four seasons. There were also pronounced changes in the monthly air temperature from November to March at decadal time scale. The seasonality (i.e., summer and winter difference) of air temperature was stronger during the period of 1960–1979 than over the recent three decades. Our preliminary analyses indicated that local environmental conditions (such as elevation) might be partly responsible for the spatial variability, and large scale climate phenomena might have influences on the temporal variability of air temperature in the Tarim Basin. In particular, there was a significant correlation between index of El Niño-Southern Oscillation (ENSO) and air temperature of May (P = 0.004), and between the index of Pacific Decadal Oscillation (PDO) and air temperature of July (P = 0.026) over the interannual to decadal time scales. PMID

  5. Nocturnal asthma in school children of south punjab, pakistan

    International Nuclear Information System (INIS)

    Mustafa, G.; Khan, P.A.; Iqbal, I.

    2008-01-01

    At the present time, the epidemiology of the childhood asthma is of considerable interest. There is an understandable concern that changes in the geographical area, lifestyle, and environment. This study was conducted to find the prevalence of nocturnal asthma, in school children of south Punjab, Pakistan. It was a cross sectional, questionnaire based, descriptive survey of the children aged 3-18 years, in randomly selected primary and secondary schools, from October 2002 to March 2003. The data was analysed with Statistical Analysis System (SAS). Of 6120 questionnaire sent to the parents/guardians, we received 3180 back (52%). Of the 3180 respondents, 1767 (56%) were for boys and 1413 (44%) were for girls. The median age was 8.25 years. Around 71% of children were between 4 to 11 years of age. The parents reported nocturnal asthma in 177 (6%) of their children with an equal prevalence in boys and girls, i.e., (3% each, rounded off to nearest whole number). Of these 177 children with nocturnal asthma, 99 (56%) were boys and 78 (44%) were girls. Of the 1767 boys and 1413 girls, the nocturnal asthma reported by parents was 6% each (99 and 78 respectively). The nocturnal asthma was not reported in 14-18 years age group of females. The asthma is taken as a stigma in our society and as such is not reported or disclosed rather denied. An extensive educational media campaign is required for awareness of the masses. (author)

  6. Sensitivity of a soil-plant-atmosphere model to changes in air temperature, dew point temperature, and solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Luxmoore, R.J. (Oak Ridge National Lab.,TN); Stolzy, J.L.; Holdeman, J.T.

    1981-01-01

    Air temperature, dew point temperature and solar radiation were independently varied in an hourly soil-plant-atmosphere model in a sensitivity analysis of these parameters. Results suggested that evapotranspiration in eastern Tennessee is limited more by meteorological conditions that determine the vapor-pressure gradient than by the necessary energy to vaporize water within foliage. Transpiration and soil water drainage were very sensitive to changes in air and dew point temperature and to solar radiation under low atmospheric vapor-pressure deficit conditions associated with reduced air temperature. Leaf water potential and stomatal conductance were reduced under conditions having high evapotranspiration. Representative air and dew point temperature input data for a particular application are necessary for satisfactory results, whereas irradiation may be less well characterized for applications with high atmospheric vapor-pressure deficit. The effects of a general rise in atmospheric temperature on forest water budgets are discussed.

  7. High-precision diode-laser-based temperature measurement for air refractive index compensation.

    Science.gov (United States)

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppä, Jeremias; Lassila, Antti

    2011-11-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement. © 2011 Optical Society of America

  8. A physically based analytical spatial air temperature and humidity model

    Science.gov (United States)

    Yang Yang; Theodore A. Endreny; David J. Nowak

    2013-01-01

    Spatial variation of urban surface air temperature and humidity influences human thermal comfort, the settling rate of atmospheric pollutants, and plant physiology and growth. Given the lack of observations, we developed a Physically based Analytical Spatial Air Temperature and Humidity (PASATH) model. The PASATH model calculates spatial solar radiation and heat...

  9. ANALISIS PEMANFAATAN DUA ELEMEN PELTIER PADA PENGONTROLAN TEMPERATUR AIR

    OpenAIRE

    Yusfi, Meqorry; Gandi, Frima; Palka, Heru Sagito

    2017-01-01

    Abstrak Elemen peltier bisa digunakan sebagai pemanas dan pendingin. Pada penelitian ini elemen peltier digunakan sebagai pendingin air. Tujuan dari penelitian ini adalah untuk membandingkan hasil pemakaian antara satu dan dua elemen peltier pada sistem kontrol temperatur air. Alat dirancang dengan menggunakan LM35 sebagai sensor temperatur dan mikrokontroler Atmega 8535 untuk mengontrol sebelum ditampilkan ke LCD. Sistem kontrol On-off digunakan pada sistem ini. Hasil penelitian menunjukk...

  10. SPATIAL PREDICTION OF AIR TEMPERATURE IN EAST CENTRAL ANATOLIA OF TURKEY

    Directory of Open Access Journals (Sweden)

    B. C. Bilgili

    2017-11-01

    Full Text Available Air temperature is an essential component of the factors used in landscape planning. At similar topographic conditions, vegetation may show considerable differences depending on air temperature and precipitation. In large areas, measuring temperature is a cost and time-consuming work. Therefore, prediction of climate variables at unmeasured sites at an acceptable accuracy is very important in regional resource planning. In addition, use a more proper prediction method is crucial since many different prediction techniques yield different performance in different landscape and geographical conditions. We compared inverse distance weighted (IDW, ordinary kriging (OK, and ordinary cokriging (OCK to predict air temperature at unmeasured sites in Malatya region (East Central Anatolia of Turkey. Malatya region is the most important apricot production area of Turkey and air temperature is the most important factor determining the apricot growing zones in this region. We used mean monthly temperatures from 1975 to 2010 measured at 28 sites in the study area and predicted temperature with IDW, OC, and OCK techniques, mapped temperature in the region, and tested the reliability of these maps. The OCK with elevation as an auxiliary variable occurred the best procedure to predict temperature against the criteria of model efficiency and relative root mean squared error.

  11. Nocturnal motor activity in fibromyalgia patients with poor sleep quality.

    Science.gov (United States)

    Hyyppä, M T; Kronholm, E

    1995-01-01

    Nocturnal motor activity was examined in long-term rehabilitation patients complaining of poor sleep and having fibromyalgia syndrome (N = 24) or other musculoskeletal disorders (N = 60) and compared with that in 91 healthy controls drawn from a random community sample. Self-reports on sleep complaints and habits were collected. The frequency of nocturnal body movements, the "apnoea" index and ratio of "quiet sleep" to total time in bed were measured using the Static Charge Sensitive Bed (SCSB) (BioMatt). As a group, patients with fibromyalgia syndrome did not differ from patients with other musculoskeletal disorders or from healthy controls in their nocturnal motor activity. The "apnoea" index was a little higher in the fibromyalgia group than in the healthy control group but did not differ from that of the group of other musculoskeletal patients. Further multivariate analyses adjusted for age, BMI, medication and "apnoea" index did not support the assumption that an increased nocturnal motor activity characterizes patients with fibromyalgia syndrome.

  12. Discussion on Boiler Efficiency Correction Method with Low Temperature Economizer-Air Heater System

    Science.gov (United States)

    Ke, Liu; Xing-sen, Yang; Fan-jun, Hou; Zhi-hong, Hu

    2017-05-01

    This paper pointed out that it is wrong to take the outlet flue gas temperature of low temperature economizer as exhaust gas temperature in boiler efficiency calculation based on GB10184-1988. What’s more, this paper proposed a new correction method, which decomposed low temperature economizer-air heater system into two hypothetical parts of air preheater and pre condensed water heater and take the outlet equivalent gas temperature of air preheater as exhaust gas temperature in boiler efficiency calculation. This method makes the boiler efficiency calculation more concise, with no air heater correction. It has a positive reference value to deal with this kind of problem correctly.

  13. Estimation of thermal sensation during varied air temperature conditions.

    Science.gov (United States)

    Katsuura, T; Tabuchi, R; Iwanaga, K; Harada, H; Kikuchi, Y

    1998-03-01

    Seven male students were exposed to four varied air temperature environments: hot (37 degrees C) to neutral (27 degrees C) (HN), neutral to hot (NH), cool (17 degrees C) to neutral (CN), and neutral to cool (NC). The air temperature was maintained at the first condition for 20 min, then was changed to the second condition after 15 min and was held there for 20 min. Each subject wore a T-shirt, briefs, trunks, and socks. Each sat on a chair and was continuously evaluated for thermal sensation, thermal comfort, and air velocity sensation. Some physiological and thermal parameters were also measured every 5 s during the experiment. The correlation between thermal sensation and skin temperature at 15 sites was found to be poor. The subjects felt much warmer during the rising phase of the air temperature (CN, NH) than during the descending phase (HN, NC) at a given mean skin temperature. However, thermal sensation at the same heat flux or at the same value of the difference between skin and air temperature (delta(Tsk - Ta)) was not so different among the four experimental conditions, and the correlation between thermal sensation and heat flux or delta(Tsk - Ta) was fairly good. The multiple regression equation of the thermal sensation (TS) on 15 sites of skin temperature (Tsk; degrees C) was calculated and the coefficient of determination (R*2) was found to be 0.656. Higher coefficients of determination were found in the equations of thermal sensation for the heat flux (H; kcal.m-2.h-1) at the right and left thighs of the subjects and on delta(Tsk - Ta) (degrees C) at 4 sites. They were as follows: TS = 2.04 - 0.016 Hright - 0.036 Hleft; R*2 = 0.717, TS = 1.649 + 0.013 delta(Tsk - Ta)UpperArm - 0.036 delta(Tsk - Ta)Chest - 0.223 delta(Tsk - Ta)Thigh-0.083 delta(Tsk - Ta)LowerLeg; R*2 = 0.752, respectively.

  14. Hearing is not necessarily believing in nocturnal anurans

    OpenAIRE

    Richardson, Christina; Gomez, Doris; Durieux, Romain; Théry, Marc; Joly, Pierre; Léna, Jean-Paul; Plénet, Sandrine; Lengagne, Thierry

    2010-01-01

    The recent discovery of the use of visual cues for mate choice by nocturnal acoustic species raises the important, and to date unaddressed, question of how these signals affect the outcome of mate choice predicted by female preference for male calls. In order to address this question, we presented female Hyla arborea tree frogs with a series of choices between combinations of acoustic and visual cues of varying quality in nocturnal conditions. While females exhibited the expected preference f...

  15. Inversion Build-Up and Cold-Air Outflow in a Small Alpine Sinkhole

    Science.gov (United States)

    Lehner, Manuela; Whiteman, C. David; Dorninger, Manfred

    2017-06-01

    Semi-idealized model simulations are made of the nocturnal cold-air pool development in the approximately 1-km wide and 100-200-m deep Grünloch basin, Austria. The simulations show qualitatively good agreement with vertical temperature and wind profiles and surface measurements collected during a meteorological field expedition. A two-layer stable atmosphere forms in the basin, with a very strong inversion in the lowest part, below the approximate height of the lowest gap in the surrounding orography. The upper part of the stable layer is less strongly stratified and extends to the approximate height of the second-lowest gap. The basin atmosphere cools most strongly during the first few hours of the night, after which temperatures decrease only slowly. An outflow of air forms through the lowest gap in the surrounding orography. The outflow connects with a weak inflow of air through a gap on the opposite sidewall, forming a vertically and horizontally confined jet over the basin. Basin cooling shows strong sensitivity to surface-layer characteristics, highlighting the large impact of variations in vegetation and soil cover on cold-air pool development, as well as the importance of surface-layer parametrization in numerical simulations of cold-air-pool development.

  16. Does the Age of Donor Kidneys Affect Nocturnal Polyuria in Patients With Successful Real Transplantation?

    Science.gov (United States)

    Mitsui, T; Morita, K; Iwami, D; Kitta, T; Kanno, Y; Moriya, K; Takeda, M; Shinohara, N

    We investigated whether the age of donor kidneys influences the incidence of nocturnal polyuria in patients with successful renal transplantation (RTX). Eighty-five patients (45 men and 40 women) undergoing RTX (median age, 47 years) were included in this study. Twenty-four-hour bladder diaries were kept for 3 days, and nocturnal polyuria was defined as a nocturnal polyuria index (nocturnal urine volume/24-hour urine volume) of >0.33. Risk factors for nocturnal polyuria were analyzed in patients with RTX by means of the Mann-Whitney U test, χ 2 test, and a logistic regression analysis. End-stage renal disease (ESRD) developed from diabetes mellitus in 16 patients (19%). Sixty-five patients (76%) received pre-transplant dialysis, with a median duration of 5 years. The median serum creatinine level and body mass index at the most recent visit were 1.2 mg/dL and 21.2 kg/m 2 , respectively. On the basis of the 24-hour bladder diaries, nocturnal polyuria was identified in 48 patients (56%). A logistic regression analysis revealed that diabetes mellitus as the original disease for ESRD was the only risk factor for nocturnal polyuria (odds ratio, 8.95; 95% confidence interval, 2.01-65.3; P = .0028). The age of donor kidneys at examination did not affect the incidence of nocturnal polyuria (P = .9402). Nocturnal polyuria was not uncommon in patients with successful RTX. Diabetes mellitus as the original disease for ESRD was the only risk factor for nocturnal polyuria, whereas the age of donor kidneys at examination did not affect the incidence of nocturnal polyuria. Thus, nocturnal polyuria is caused by recipient factors but not donor factors. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Comparing the effects of nocturnal sleep and daytime napping on declarative memory consolidation.

    Directory of Open Access Journals (Sweden)

    June C Lo

    Full Text Available Nocturnal sleep and daytime napping facilitate memory consolidation for semantically related and unrelated word pairs. We contrasted forgetting of both kinds of materials across a 12-hour interval involving either nocturnal sleep or daytime wakefulness (experiment 1 and a 2-hour interval involving either daytime napping or wakefulness (experiment 2. Beneficial effects of post-learning nocturnal sleep and daytime napping were greater for unrelated word pairs (Cohen's d=0.71 and 0.68 than for related ones (Cohen's d=0.58 and 0.15. While the size of nocturnal sleep and daytime napping effects was similar for unrelated word pairs, for related pairs, the effect of nocturnal sleep was more prominent. Together, these findings suggest that sleep preferentially facilitates offline memory processing of materials that are more susceptible to forgetting.

  18. Comparing the effects of nocturnal sleep and daytime napping on declarative memory consolidation.

    Science.gov (United States)

    Lo, June C; Dijk, Derk-Jan; Groeger, John A

    2014-01-01

    Nocturnal sleep and daytime napping facilitate memory consolidation for semantically related and unrelated word pairs. We contrasted forgetting of both kinds of materials across a 12-hour interval involving either nocturnal sleep or daytime wakefulness (experiment 1) and a 2-hour interval involving either daytime napping or wakefulness (experiment 2). Beneficial effects of post-learning nocturnal sleep and daytime napping were greater for unrelated word pairs (Cohen's d=0.71 and 0.68) than for related ones (Cohen's d=0.58 and 0.15). While the size of nocturnal sleep and daytime napping effects was similar for unrelated word pairs, for related pairs, the effect of nocturnal sleep was more prominent. Together, these findings suggest that sleep preferentially facilitates offline memory processing of materials that are more susceptible to forgetting.

  19. A physically based analytical spatial air temperature and humidity model

    Science.gov (United States)

    Yang, Yang; Endreny, Theodore A.; Nowak, David J.

    2013-09-01

    Spatial variation of urban surface air temperature and humidity influences human thermal comfort, the settling rate of atmospheric pollutants, and plant physiology and growth. Given the lack of observations, we developed a Physically based Analytical Spatial Air Temperature and Humidity (PASATH) model. The PASATH model calculates spatial solar radiation and heat storage based on semiempirical functions and generates spatially distributed estimates based on inputs of topography, land cover, and the weather data measured at a reference site. The model assumes that for all grids under the same mesoscale climate, grid air temperature and humidity are modified by local variation in absorbed solar radiation and the partitioning of sensible and latent heat. The model uses a reference grid site for time series meteorological data and the air temperature and humidity of any other grid can be obtained by solving the heat flux network equations. PASATH was coupled with the USDA iTree-Hydro water balance model to obtain evapotranspiration terms and run from 20 to 29 August 2010 at a 360 m by 360 m grid scale and hourly time step across a 285 km2 watershed including the urban area of Syracuse, NY. PASATH predictions were tested at nine urban weather stations representing variability in urban topography and land cover. The PASATH model predictive efficiency R2 ranged from 0.81 to 0.99 for air temperature and 0.77 to 0.97 for dew point temperature. PASATH is expected to have broad applications on environmental and ecological models.

  20. Interactive Effect of Air-Water Ratio and Temperature on the Air ...

    African Journals Online (AJOL)

    Windows User

    KEYWORDS: Interactive effect, air-water ratio, temperature, volatile organic compounds, removal efficiency. [Received ... The rate of mass transfer of a VOC from wastewater to the ... where ΔHo is heat of evaporation of 1 mole of component.

  1. Interaction between Soil Moisture and Air Temperature in the Mississippi River Basin

    Science.gov (United States)

    Increasing air temperatures are expected to continue in the future. The relation between soil moisture and near surface air temperature is significant for climate change and climate extremes. Evaluation of the relations between soil moisture and temperature was performed by devel...

  2. Can air temperature be used to project influences of climate change on stream temperature?

    Science.gov (United States)

    Ivan Arismendi; Mohammad Safeeq; Jason B Dunham; Sherri L Johnson

    2014-01-01

    Worldwide, lack of data on stream temperature has motivated the use of regression-based statistical models to predict stream temperatures based on more widely available data on air temperatures. Such models have been widely applied to project responses of stream temperatures under climate change, but the performance of these models has not been fully evaluated. To...

  3. Ocellar optics in nocturnal and diurnal bees and wasps.

    Science.gov (United States)

    Warrant, Eric J; Kelber, Almut; Wallén, Rita; Wcislo, William T

    2006-12-01

    Nocturnal bees, wasps and ants have considerably larger ocelli than their diurnal relatives, suggesting an active role in vision at night. In a first step to understanding what this role might be, the morphology and physiological optics of ocelli were investigated in three tropical rainforest species - the nocturnal sweat bee Megalopta genalis, the nocturnal paper wasp Apoica pallens and the diurnal paper wasp Polistes occidentalis - using hanging-drop techniques and standard histological methods. Ocellar image quality, in addition to lens focal length and back focal distance, was determined in all three species. During flight, the ocellar receptive fields of both nocturnal species are centred very dorsally, possibly in order to maximise sensitivity to the narrow dorsal field of light that enters through gaps in the rainforest canopy. Since all ocelli investigated had a slightly oval shape, images were found to be astigmatic: images formed by the major axis of the ocellus were located further from the proximal surface of the lens than images formed by the minor axis. Despite being astigmatic, images formed at either focal plane were reasonably sharp in all ocelli investigated. When compared to the position of the retina below the lens, measurements of back focal distance reveal that the ocelli of Megalopta are highly underfocused and unable to resolve spatial detail. This together with their very large and tightly packed rhabdoms suggests a role in making sensitive measurements of ambient light intensity. In contrast, the ocelli of the two wasps form images near the proximal boundary of the retina, suggesting the potential for modest resolving power. In light of these results, possible roles for ocelli in nocturnal bees and wasps are discussed, including the hypothesis that they might be involved in nocturnal homing and navigation, using two main cues: the spatial pattern of bright patches of daylight visible through the rainforest canopy, and compass information

  4. Ambient air pollution, temperature and out-of-hospital coronary deaths in Shanghai, China

    International Nuclear Information System (INIS)

    Dai, Jinping; Chen, Renjie; Meng, Xia; Yang, Changyuan; Zhao, Zhuohui; Kan, Haidong

    2015-01-01

    Few studies have evaluated the effects of ambient air pollution and temperature in triggering out-of-hospital coronary deaths (OHCDs) in China. We evaluated the associations of air pollution and temperature with daily OHCDs in Shanghai, China from 2006 to 2011. We applied an over-dispersed generalized additive model and a distributed lag nonlinear model to analyze the effects of air pollution and temperature, respectively. A 10 μg/m 3 increase in the present-day PM 10 , PM 2.5 , SO 2 , NO 2 and CO were associated with increases in OHCD mortality of 0.49%, 0.68%, 0.88%, 1.60% and 0.08%, respectively. A 1 °C decrease below the minimum-mortality temperature corresponded to a 3.81% increase in OHCD mortality on lags days 0–21, and a 1 °C increase above minimum-mortality temperature corresponded to a 4.61% increase over lag days 0–3. No effects were found for in-hospital coronary deaths. This analysis suggests that air pollution, low temperature and high temperature may increase the risk of OHCDs. - Highlights: • Few studies have evaluated the effects of air pollution and temperature on OHCDs in China. • The present-day concentrations of air pollution were associated with OHCDs. • The effect of high temperatures on OHCDs was more immediate than low temperatures. • No significant effects were found for in-hospital coronary deaths. - Ambient air pollution and temperature may trigger out-of-hospital coronary deaths but not in-hospital coronary deaths

  5. Adaptive strategies in nocturnally migrating insects and songbirds: contrasting responses to wind.

    Science.gov (United States)

    Chapman, Jason W; Nilsson, Cecilia; Lim, Ka S; Bäckman, Johan; Reynolds, Don R; Alerstam, Thomas

    2016-01-01

    Animals that use flight as their mode of transportation must cope with the fact that their migration and orientation performance is strongly affected by the flow of the medium they are moving in, that is by the winds. Different strategies can be used to mitigate the negative effects and benefit from the positive effects of a moving flow. The strategies an animal can use will be constrained by the relationship between the speed of the flow and the speed of the animal's own propulsion in relation to the surrounding air. Here we analyse entomological and ornithological radar data from north-western Europe to investigate how two different nocturnal migrant taxa, the noctuid moth Autographa gamma and songbirds, deal with wind by analysing variation in resulting flight directions in relation to the wind-dependent angle between the animal's heading and track direction. Our results, from fixed locations along the migratory journey, reveal different global strategies used by moths and songbirds during their migratory journeys. As expected, nocturnally migrating moths experienced a greater degree of wind drift than nocturnally migrating songbirds, but both groups were more affected by wind in autumn than in spring. The songbirds' strategies involve elements of both drift and compensation, providing some benefits from wind in combination with destination and time control. In contrast, moths expose themselves to a significantly higher degree of drift in order to obtain strong wind assistance, surpassing the songbirds in mean ground speed, at the cost of a comparatively lower spatiotemporal migratory precision. Moths and songbirds show contrasting but adaptive responses to migrating through a moving flow, which are fine-tuned to the respective flight capabilities of each group in relation to the wind currents they travel within. © 2015 The Authors. Journal of Animal Ecology © 2015 British Ecological Society.

  6. Temperature distribution in graphite during annealing in air cooled reactors

    International Nuclear Information System (INIS)

    Oliveira Avila, C.R. de.

    1989-01-01

    A model for the evaluation temperature distributions in graphite during annealing operation in graphite. Moderated an-cooled reactors, is presented. One single channel and one dimension for air and graphite were considered. A numerical method based on finite control volumes was used for partioning the mathematical equations. The problem solution involves the use of unsteady equations of mass, momentum and energy conservation for air, and energy conservation for graphite. The source term was considered as stored energy release during annealing for describing energy conservation in the graphite. The coupling of energy conservation equations in air and graphite is performed by the heat transfer term betwen air and graphite. The results agree with experimental data. A sensitivity analysis shown that the termal conductivity of graphite and the maximum inlet channel temperature have great effect on the maximum temperature reached in graphite during the annealing. (author)

  7. Nocturnal sleep pattern in native Brazilian Terena adults

    Directory of Open Access Journals (Sweden)

    REIMÃO RUBENS

    2000-01-01

    Full Text Available Social-economic factors influence sleep habits. This research analyzes characteristics of nocturnal sleep in Brazilian Native Terena adults. Sixty-four adults (31 M; 33 F from 18 to 75 years, with a mean age of 37.0, from the Indian Reservation village of Córrego do Meio, in the central region of Mato Grosso do Sul, an agriculturally oriented group were evaluated. Nocturnal sleep characteristics were evaluated by means of a standard questionnaire applied to each individual. It was observed that reported nocturnal sleep was longer, sleep onset was earlier and wake up time was also earlier than usually described in urban populations. The mean total time in bed was 8.5 h or more, in every age bracket. The seven-day prevalence rate of insomnia was 4.6%, while the seven-day prevalence rate of hypnotic use was 1.5%, both remarkably less than described in urban populations. These findings stress the need to consider ethnic influences on sleep patterns and disorders.

  8. Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria

    Science.gov (United States)

    Correia, Rodolfo Patussi; Bento, Laiz Cameirão; Bortolucci, Ana Carolina Apelle; Alexandre, Anderson Marega; Vaz, Andressa da Costa; Schimidell, Daniela; Pedro, Eduardo de Carvalho; Perin, Fabricio Simões; Nozawa, Sonia Tsukasa; Mendes, Cláudio Ernesto Albers; Barroso, Rodrigo de Souza; Bacal, Nydia Strachman

    2016-01-01

    ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones. PMID:27759825

  9. Single-footprint retrievals of temperature, water vapor and cloud properties from AIRS

    Science.gov (United States)

    Irion, Fredrick W.; Kahn, Brian H.; Schreier, Mathias M.; Fetzer, Eric J.; Fishbein, Evan; Fu, Dejian; Kalmus, Peter; Wilson, R. Chris; Wong, Sun; Yue, Qing

    2018-02-01

    Single-footprint Atmospheric Infrared Sounder spectra are used in an optimal estimation-based algorithm (AIRS-OE) for simultaneous retrieval of atmospheric temperature, water vapor, surface temperature, cloud-top temperature, effective cloud optical depth and effective cloud particle radius. In a departure from currently operational AIRS retrievals (AIRS V6), cloud scattering and absorption are in the radiative transfer forward model and AIRS single-footprint thermal infrared data are used directly rather than cloud-cleared spectra (which are calculated using nine adjacent AIRS infrared footprints). Coincident MODIS cloud data are used for cloud a priori data. Using single-footprint spectra improves the horizontal resolution of the AIRS retrieval from ˜ 45 to ˜ 13.5 km at nadir, but as microwave data are not used, the retrieval is not made at altitudes below thick clouds. An outline of the AIRS-OE retrieval procedure and information content analysis is presented. Initial comparisons of AIRS-OE to AIRS V6 results show increased horizontal detail in the water vapor and relative humidity fields in the free troposphere above the clouds. Initial comparisons of temperature, water vapor and relative humidity profiles with coincident radiosondes show good agreement. Future improvements to the retrieval algorithm, and to the forward model in particular, are discussed.

  10. Measuring centimeter-resolution air temperature profiles above land and water using fiber-optic Distributed Temperature Sensing

    Science.gov (United States)

    Sigmund, Armin; Pfister, Lena; Olesch, Johannes; Thomas, Christoph K.

    2016-04-01

    The precise determination of near-surface air temperature profiles is of special importance for the characterization of airflows (e.g. cold air) and the quantification of sensible heat fluxes according to the flux-gradient similarity approach. In contrast to conventional multi-sensor techniques, measuring temperature profiles using fiber-optic Distributed Temperature Sensing (DTS) provides thousands of measurements referenced to a single calibration standard at much reduced costs. The aim of this work was to enhance the vertical resolution of Raman scatter DTS measurements up to the centimeter-scale using a novel approach for atmospheric applications: the optical fiber was helically coiled around a meshed fabric. In addition to testing the new fiber geometry, we quantified the measurement uncertainty and demonstrated the benefits of the enhanced-resolution profiles. The fiber-optic cable was coiled around a hollow column consisting of white reinforcing fabric supported by plexiglass rings every meter. Data from two columns of this type were collected for 47 days to measure air temperature vertically over 3.0 and 5.1 m over a gently inclined meadow and over and in a small lake, respectively. Both profiles had a vertical resolution of 1 cm in the lower section near the surface and 5 cm in the upper section with an along-fiber instrument-specific averaging of 1.0 m and a temporal resolution of 30 s. Measurement uncertainties, especially from conduction between reinforcing fabric and fiber-optic cable, were estimated by modeling the fiber temperature via a detailed energy balance approach. Air temperature, wind velocity and radiation components were needed as input data and measured separately. The temperature profiles revealed valuable details, especially in the lowest 1 m above surface. This was best demonstrated for nighttime observations when artefacts due to solar heating did not occur. For example, the dynamics of a cold air layer was detected in a clear night

  11. The relationship between nocturnal polyuria and the distribution of body fluid: assessment by bioelectric impedance analysis.

    Science.gov (United States)

    Torimoto, Kazumasa; Hirayama, Akihide; Samma, Shoji; Yoshida, Katsunori; Fujimoto, Kiyohide; Hirao, Yoshihiko

    2009-01-01

    Increased nocturnal urinary volume is closely associated with nocturia. We investigated the relationship between nocturnal polyuria and the variation of body fluid distribution during the daytime using bioelectric impedance analysis. A total of 34 men older than 60 years were enrolled in this study. A frequency volume chart was recorded. Nocturnal polyuria was defined as a nocturnal urine volume per 24-hour production of greater than 0.35 (the nocturnal polyuria index). Bioelectric impedance analysis was performed 4 times daily at 8 and 11 a.m., and 5 and 9 p.m. using an InBody S20 body composition analyzer (BioSpace, Seoul, Korea). A significant difference was found in mean +/- SEM 24-hour urine production per fat-free mass between the groups with and without nocturnal polyuria (17.8 +/- 1.4 vs 7.7 +/- 0.9 ml/kg). The increase in fluid in the legs compared with the volume at 8 a.m. was significantly larger at 5 p.m., while there was no difference in the arms or trunk. Nocturnal urine volume significantly correlated with the difference in fluid volume in the legs (r = 0.527, p = 0.0019) and extracellular fluid volume (r = 0.3844, p = 0.0248) between the volumes at 8 a.m. and 9 p.m. Overproduction of urine per fat-free mass leads to nocturnal polyuria. Extracellular fluid accumulates as edema in the legs during the day in patients with nocturnal polyuria. The volume of accumulated extracellular fluid correlates with nocturnal urine volume. We suggest that leg edema is the source of nocturnal urine volume and decreasing edema may cure nocturnal polyuria.

  12. Pregnancy and paroxysmal nocturnal hemoglobinuria

    NARCIS (Netherlands)

    Bais, J.; Pel, M.; von dem Borne, A.; van der Lelie, H.

    1994-01-01

    A patient is described who developed symptoms of paroxysmal nocturnal hemoglobinuria (PNH) in her first pregnancy. This was uneventful except for a spontaneous preterm delivery. The second pregnancy was complicated by severe anemia and a hemolytic crisis with Budd-Chiari syndrome at 31 weeks'

  13. Observations of Air Quality at the Edge of Kathmandu, Nepal, and the Diurnal Cycle of Air Pollution In and Around the Kathmandu Valley

    Science.gov (United States)

    Panday, A. K.; Prinn, R. G.; Regmi, R. P.

    2006-12-01

    The Kathmandu Valley is a bowl-shaped basin in the Nepal Himalaya, with a rapidly growing city surrounded by rice fields and steep terraced and forested mountain slopes. The valley's air quality is influenced by urban and rural emissions, nocturnal pooling of cold air, slope winds, and a daily exchange of air through mountain passes. To understand these processes and to inform air pollution policy in Nepal, we have carried out the most comprehensive study of air pollution in Nepal to date. During the 9-month dry season of 2004-2005, we carried out continuous measurements every minute of carbon monoxide, ozone, PM10, wind speed, wind direction, solar radiation, temperature, and humidity on the eastern edge of Kathmandu city, at a site that daily received air from both the city and rural areas. We recorded the diurnal cycle of the vertical temperature structure and stability with temperature loggers on towers and mountains. A sodar measured the mixed layer height and upper-level winds. 24-hour simultaneous bag sampling campaigns on mountain peaks, passes, the rural valley, and within the city provided glimpses of the spatial patterns of the diurnal cycle of CO -- a useful tracer of anthropogenic emissions. We measured winds on mountain passes and ozone on mountain peaks. At our main measurement site we found a daily-recurring pattern of CO and PM10, with an afternoon low showing rural background levels, even though the arriving air had traversed the city. This was followed by an evening peak starting at sunset, a second low late at night, and a morning peak enhanced by re-circulation. Pollutants emitted in the valley only traveled out of the valley between the late morning and sunset. During winter months, rush hour was outside of this period, enhancing the morning and evening peaks. Within the city, ozone dropped to zero at night. At mid-day we observed an ozone peak enhanced by photochemical production when the air mass that had been stagnant over the city swept

  14. Mapping air temperature using time series analysis of LST : The SINTESI approach

    NARCIS (Netherlands)

    Alfieri, S.M.; De Lorenzi, F.; Menenti, M.

    2013-01-01

    This paper presents a new procedure to map time series of air temperature (Ta) at fine spatial resolution using time series analysis of satellite-derived land surface temperature (LST) observations. The method assumes that air temperature is known at a single (reference) location such as in gridded

  15. Impact of nocturnal heartburn on quality of life, sleep, and productivity: the SINERGE study.

    Science.gov (United States)

    Calleja, José Luis; Bixquert, M; Maldonado, J

    2007-10-01

    The aim of the SINERGE study was to assess the impact of nocturnal heartburn on quality of life, sleep, and productivity. Ambulatory patients >/=18 years old and classified as defined cases of nocturnal heartburn (n=337), nonnocturnal heartburn (n=139), uncontrolled hypertension (n=198), and symptomatic depression (n=104) were included in this cross-sectional study. Information on age, gender, body mass index, and comorbidity was collected and the following validated questionnaires were applied: SF-12, Pittsburgh Sleep Quality Index, and Work Productivity and Activity Impairment questionnaire. The prevalence of primary care consultation for heartburn and nocturnal heartburn was 4.7% and 1.9%, respectively. Health-related quality of life, sleep, and productivity were significantly impaired in patients with frequent nocturnal heartburn symptoms as compared with those of the patients without nocturnal symptoms or patients with hypertension. Nocturnal heartburn poses a considerable burden for the sufferer because of the impact on quality of life, sleep, and daily activities.

  16. An experimental study of thermal comfort at different combinations of air and mean radiant temperature

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.

    2009-01-01

    It is often discussed if a person prefers a low air temperature (ta) and a high mean radiant temperature (tr), vice-versa or it does not matter as long as the operative temperature is acceptable. One of the hypotheses is that it does not matter for thermal comfort but for perceived air quality......, a lower air temperature is preferred. This paper presents an experimental study with 30 human subjects exposed to three different combinations of air- and mean radiant temperature with an operative temperature around 23 °C. The subjects gave subjective evaluations of thermal comfort and perceived air...... quality during the experiments. The PMV-index gave a good estimation of thermal sensation vote (TSV) when the air and mean radiant temperature were the same. In the environment with different air- and mean radiant temperatures, a thermal comfort evaluation shows an error up to 1 scale unit on the 7-point...

  17. Sleep Apnea and Nocturnal Cardiac Arrhythmia: A Populational Study

    Directory of Open Access Journals (Sweden)

    Fatima Dumas Cintra

    2014-11-01

    Full Text Available Background: The mechanisms associated with the cardiovascular consequences of obstructive sleep apnea include abrupt changes in autonomic tone, which can trigger cardiac arrhythmias. The authors hypothesized that nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea. Objective: To analyze the relationship between obstructive sleep apnea and abnormal heart rhythm during sleep in a population sample. Methods: Cross-sectional study with 1,101 volunteers, who form a representative sample of the city of São Paulo. The overnight polysomnography was performed using an EMBLA® S7000 digital system during the regular sleep schedule of the individual. The electrocardiogram channel was extracted, duplicated, and then analyzed using a Holter (Cardio Smart® system. Results: A total of 767 participants (461 men with a mean age of 42.00 ± 0.53 years, were included in the analysis. At least one type of nocturnal cardiac rhythm disturbance (atrial/ventricular arrhythmia or beat was observed in 62.7% of the sample. The occurrence of nocturnal cardiac arrhythmias was more frequent with increased disease severity. Rhythm disturbance was observed in 53.3% of the sample without breathing sleep disorders, whereas 92.3% of patients with severe obstructive sleep apnea showed cardiac arrhythmia. Isolated atrial and ventricular ectopy was more frequent in patients with moderate/severe obstructive sleep apnea when compared to controls (p < 0.001. After controlling for potential confounding factors, age, sex and apnea-hypopnea index were associated with nocturnal cardiac arrhythmia. Conclusion: Nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea and the prevalence increases with disease severity. Age, sex, and the Apnea-hypopnea index were predictors of arrhythmia in this sample.

  18. The Effects of Air Pollution and Temperature on COPD.

    Science.gov (United States)

    Hansel, Nadia N; McCormack, Meredith C; Kim, Victor

    2016-06-01

    Chronic Obstructive Pulmonary Disease (COPD) affects 12-16 million people in the United States and is the third-leading cause of death. In developed countries, smoking is the greatest risk factor for the development of COPD, but other exposures also contribute to the development and progression of the disease. Several studies suggest, though are not definitive, that outdoor air pollution exposure is linked to the prevalence and incidence of COPD. Among individuals with COPD, outdoor air pollutants are associated with loss of lung function and increased respiratory symptoms. In addition, outdoor air pollutants are also associated with COPD exacerbations and mortality. There is much less evidence for the impact of indoor air on COPD, especially in developed countries in residences without biomass exposure. The limited existing data suggests that indoor particulate matter and nitrogen dioxide concentrations are linked to increased respiratory symptoms among patients with COPD. In addition, with the projected increases in temperature and extreme weather events in the context of climate change there has been increased attention to the effects of heat exposure. Extremes of temperature-both heat and cold-have been associated with increased respiratory morbidity in COPD. Some studies also suggest that temperature may modify the effect of pollution exposure and though results are not conclusive, understanding factors that may modify susceptibility to air pollution in patients with COPD is of utmost importance.

  19. The effect of air temperature on yield of Holstein dairy cattle

    Directory of Open Access Journals (Sweden)

    Anna Šimková

    2015-05-01

    Full Text Available The study was carried out in the agricultural company Petrovice during the summer and winter seasons. The experiment included Holstein dairy cattle. Air temperature was measured using a data logger with sensors (Datalogger COMET 3120 in the stable. Data on average yield were taken from farm records and then processed using Microsoft Excel. The aim of the study was to determine how the values of ambient temperature affect the welfare of the animals with regard to the average performance. The air temperature is very variable and its changes animals react immediately. Measured values of air temperature in the stable are important for optimal welfare. It affects the productivity of dairy cows, milk quality, reproduction and animal health.

  20. Running Club - Nocturne des Evaux

    CERN Multimedia

    Running club

    2017-01-01

    Les coureurs du CERN sont encore montés sur les plus hautes marches du podium lors de la course interentreprises. Cette course d’équipe qui se déroule de nuit et par équipe de 3 à 4 coureurs est unique dans la région de par son originalité : départ groupé toutes les 30 secondes, les 3 premiers coureurs doivent passer la ligne d’arrivée ensemble. Double victoire pour le running club a la nocturne !!!! 1ère place pour les filles et 22e au classement général; 1ère place pour l'équipe mixte et 4e au général, battant par la même occasion le record de l'épreuve en mixte d'environ 1 minute; 10e place pour l'équipe homme. Retrouvez tous les résultats sur http://www.chp-geneve.ch/web-cms/index.php/nocturne-des-evaux

  1. Diurnal and Nocturnal Pollination of Marginatocereus marginatus (Pachycereeae: Cactaceae) in Central Mexico

    Science.gov (United States)

    DAR, SALEEM; ARIZMENDI, Ma. del CORO; VALIENTE-BANUET, ALFONSO

    2006-01-01

    • Background and Aims Chiropterophillous and ornithophillous characteristics can form part of a single reproductive strategy in plants that have flowers with diurnal and nocturnal anthesis. This broader pollination strategy can ensure seed set when pollinators are scarce or unpredictable. This appears to be true of hummingbirds, which presumably pollinate Marginatocereus marginatus, a columnar cactus with red nocturnal and diurnal flowers growing as part of dense bat-pollinated columnar cacti forests in arid regions of central Mexico. The aim of this study was to study the floral biology of M. marginatus, and evaluate the effectiveness of nocturnal vs. diurnal pollinators and the contribution of each pollinator group to overall plant fitness. • Methods Individual flower buds were marked and followed to evaluate flower phenology and anthesis time. Flowers and nectar production were measured. An exclusion experiment was conducted to measure the relative contribution of nocturnal and diurnal pollinators to seed set. • Key Results Marginatocereus marginatus has red hermaphroditic flowers with nocturnal and diurnal anthesis. The plant cannot produce seeds by selfing and was pollinated during the day by hummingbirds and during the night by bats, demonstrating that both pollinator groups were important for plant reproduction. Strong pollen limitation was found in the absence of one of the pollinator guilds. • Conclusions Marginatocereus marginatus has an open pollination system in which both diurnal and nocturnal pollinators are needed to set seeds. This represents a fail-safe pollination system that can ensure both pollination, in a situation of low abundance of one of the pollinator groups (hummingbirds), and high competition for nocturnal pollinators with other columnar cacti that bloom synchronously with M. marginatus in the Tehuacan Valley, Mexico. PMID:16394025

  2. Passive radiative cooling below ambient air temperature under direct sunlight.

    Science.gov (United States)

    Raman, Aaswath P; Anoma, Marc Abou; Zhu, Linxiao; Rephaeli, Eden; Fan, Shanhui

    2014-11-27

    Cooling is a significant end-use of energy globally and a major driver of peak electricity demand. Air conditioning, for example, accounts for nearly fifteen per cent of the primary energy used by buildings in the United States. A passive cooling strategy that cools without any electricity input could therefore have a significant impact on global energy consumption. To achieve cooling one needs to be able to reach and maintain a temperature below that of the ambient air. At night, passive cooling below ambient air temperature has been demonstrated using a technique known as radiative cooling, in which a device exposed to the sky is used to radiate heat to outer space through a transparency window in the atmosphere between 8 and 13 micrometres. Peak cooling demand, however, occurs during the daytime. Daytime radiative cooling to a temperature below ambient of a surface under direct sunlight has not been achieved because sky access during the day results in heating of the radiative cooler by the Sun. Here, we experimentally demonstrate radiative cooling to nearly 5 degrees Celsius below the ambient air temperature under direct sunlight. Using a thermal photonic approach, we introduce an integrated photonic solar reflector and thermal emitter consisting of seven layers of HfO2 and SiO2 that reflects 97 per cent of incident sunlight while emitting strongly and selectively in the atmospheric transparency window. When exposed to direct sunlight exceeding 850 watts per square metre on a rooftop, the photonic radiative cooler cools to 4.9 degrees Celsius below ambient air temperature, and has a cooling power of 40.1 watts per square metre at ambient air temperature. These results demonstrate that a tailored, photonic approach can fundamentally enable new technological possibilities for energy efficiency. Further, the cold darkness of the Universe can be used as a renewable thermodynamic resource, even during the hottest hours of the day.

  3. Collecting performance of an evacuated tubular solar high-temperature air heater with concentric tube heat exchanger

    International Nuclear Information System (INIS)

    Wang, Ping-Yang; Li, Shuang-Fei; Liu, Zhen-Hua

    2015-01-01

    Highlights: • A novel evacuated tube solar high temperature air heater is designed. • The solar air heater system consists of 30 linked collecting units. • Every unit consisted of a evacuated tube, a simplified CPC and concentric tube. • The flow air is heated over temperature of 200 °C. - Abstract: A set of evacuated tube solar high temperature air heaters with simplified CPC (compound parabolic concentrator) and concentric tube heat exchanger is designed to provide flow air with a temperature of 150–230 °C for industrial production. The solar air heater system consists of 30 linked collecting units. Each unit includes a simplified CPC and an all-glass evacuated tube absorber with a concentric copper tube heat exchanger installed inside. A stainless steel mesh layer with high thermal conductivity is filled between the evacuated tube and the concentric copper tube. Air passes through each collecting unit, and its temperature increases progressively. An experimental investigation of the thermal performance of the air heater is performed, and the experimental results demonstrate the presented high-temperature solar air heater has excellent collecting performance and large output power, even in the winter. The measured thermal efficiency corresponding to the air temperature of 70 °C reaches 0.52. With the increase of air temperature, thermal efficiency reaches 0.35 at an air temperature of 150 °C, and 0.21 at an air temperature of 220 °C.

  4. Influence of air temperature on electric consumption in Moscow

    Science.gov (United States)

    Lokoshchenko, Mikhail A.; Nikolayeva, Nataliya A.

    2017-04-01

    For the first time for mid latitudes and with the use of long-term data of Moscow State University Meteorological observatory a dependence of electric power consumption E on the air temperature T has been studied for each separate day for the period from 1990 to 2015 (totally - 9496 values). As a result, it is shown that the relation is in general decreasing in conditions of cold Moscow region: energy consumption as a rule reduces with a rise of the temperature. However, in time of severe frosts the energy consumption increasing goes to nothing due to special measures for energy savings whereas during heat wave episodes of extremely hot weather (especially in summer of 2010) an opposite tendency appears to the energy consumption increase with the increase of the air temperature due to additional consumption for the air conditioning. This relation between E and T is statistically significant with extremely high confidence probability (more than 0.999). The optimum temperature for the energy saving is 18 ˚C. The air temperature limit values in Moscow during last decades have been discussed. Daily-averaged T varied from -28.0 ˚C in January of 2006 to +31.4 ˚C in August of 2010 so a range of this parameter is almost 60 ˚C. Catastrophic heat wave in 2010 appeared as a secondary summer maximum of the electric consumption annual course. The relation between E and T for separate years demonstrates strong weekly periodicity at the dynamics of E daily values. As a result statistical distribution of E daily values for separate years is bimodal. One its mode is connected with working-days and another one - with non-work days (Saturday, Sunday and holidays) when consumption is much less. In recent time weekly cycle at the electric consumption became weaker due to total fall of industry in Moscow. In recent years the dependence of energy consumption on the air temperature generally became stronger - probably due to changes of its structure (growth of non-industrial users

  5. Three Mile Island ambient-air-temperature sensor measurements

    International Nuclear Information System (INIS)

    Fryer, M.O.

    1983-01-01

    Data from the ambient-air-temperature sensors in Three Mile Island-Unit 2 (TMI-2) reactor containment building are analyzed. The data were for the period of the hydrogen burn that was part of the TMI-2 accident. From the temperature data, limits are placed on the duration of the hydrogen burn

  6. Air and ground temperatures along elevation and continentality gradients in Southern Norway

    Science.gov (United States)

    Farbrot, Herman; Hipp, Tobias; Etzelmüller, Bernd; Humlum, Ole; Isaksen, Ketil; Strand Ødegârd, Rune

    2010-05-01

    The modern southern boundary for Scandinavian permafrost is located in the mountains of Southern Norway. Permafrost and seasonal frost are considered key components of the cryosphere, and the climate-permafrost relation has acquired added importance with the increasing awareness and concern of rising air temperatures. The three-year research project CRYOLINK ("Permafrost and seasonal frost in southern Norway") aims at improving knowledge on past and present ground temperatures, seasonal frost, and distribution of mountain permafrost in Southern Norway by addressing the fundamental problem of heat transfer between the atmosphere and the ground surface. Hence, several shallow boreholes have been drilled, and a monitoring program to measure air and ground temperatures was started August 2008. The borehole areas (Juvvass, Jetta and Tron) are situated along a west-east transect and, hence, a continentality gradient, and each area provides boreholes at different elevations. Here we present the first year of air and ground temperatures from these sites and discuss the influence of air temperature and ground surface charcteristics (snow conditions, sediments/bedrock, vegetation) on ground temperatures.

  7. Targeting nocturnal hypertension in type 2 diabetes mellitus.

    Science.gov (United States)

    Rossen, Niklas Blach; Knudsen, Søren Tang; Fleischer, Jesper; Hvas, Anne-Mette; Ebbehøj, Eva; Poulsen, Per Løgstrup; Hansen, Klavs Würgler

    2014-11-01

    Several studies in different populations have suggested that nighttime blood pressure (BP) is a stronger predictor of cardiovascular events than daytime BP. Consequently, treatment strategies to target nighttime BP have come into focus. The aim of the present study was to investigate the effect of change of administration time of antihypertensive drugs. We included 41 patients with type 2 diabetes mellitus and nocturnal hypertension (nighttime systolic BP >120 mm Hg) in an open-label, crossover study. Patients were randomized to 8 weeks of either morning or bedtime administration of all of the individual's once-daily antihypertensive drugs, followed by 8 weeks of switched dosing regimen. Bedtime administration of antihypertensive drugs resulted in a significant reduction in nighttime (7.5 mm Hg; Pdiabetes mellitus and nocturnal hypertension, administration of once-daily antihypertensive drugs at bedtime may be favorable. The increased nocturnal natriuresis may reflect increased effect of bedtime-administered thiazides and renin-angiotensin system inhibitors, suggesting a potential mechanism of the observed effects on BP with chronotherapeutic intervention. © 2014 American Heart Association, Inc.

  8. Sensor-based evaluation and treatment of nocturnal hypokinesia in Parkinson's disease: An evidence-based review.

    Science.gov (United States)

    Bhidayasiri, Roongroj; Sringean, Jirada; Thanawattano, Chusak

    2016-01-01

    The manifestations of nocturnal movements in Parkinson's disease (PD) are protean, with major disabilities related to nocturnal hypokinesia. While it can be assessed by clinical interviews and screening instruments, these are often inaccurate and prone to recall bias. In light of advances in sensor technology, we explored the use of sensors in the study of nocturnal hypokinesia, by performing a systematic review of the professional literature on this topic. Evidence suggests that nocturnal hypokinesia exists even in patients in the early stages, and PD patients turned significantly less and with much slower speed and acceleration than controls, partly related to low nocturnal dopamine level. We conducted another systematic review to evaluate the evidence of the efficacy of dopaminergic agents in the treatment of nocturnal hypokinesia. Several lines of evidence support the use of long-acting drugs or by continuous administration of short-acting agents to control symptoms. Sensor parameters could be considered as one of the important objective outcomes in future clinical trials investigating potential drugs to treat nocturnal hypokinesia. Physicians should be aware of this technology as it can aid the clinical assessment of nocturnal hypokinesia and enhance the quality of patient care. In addition, the use of sensors currently is being considered for various aspects of research on early diagnosis, treatment, and rehabilitation of PD patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Temperature profile and producer gas composition of high temperature air gasification of oil palm fronds

    International Nuclear Information System (INIS)

    Guangul, F M; Sulaiman, S A; Ramli, A

    2013-01-01

    Environmental pollution and scarcity of reliable energy source are the current pressing global problems which need a sustainable solution. Conversion of biomass to a producer gas through gasification process is one option to alleviate the aforementioned problems. In the current research the temperature profile and composition of the producer gas obtained from the gasification of oil palm fronds by using high temperature air were investigated and compared with unheated air. By preheating the gasifying air at 500°C the process temperature were improved and as a result the concentration of combustible gases and performance of the process were improved. The volumetric percentage of CO, CH4 and H2 were improved from 22.49, 1.98, and 9.67% to 24.98, to 2.48% and 13.58%, respectively. In addition, HHV, carbon conversion efficiency and cold gas efficiency were improver from 4.88 MJ/Nm3, 83.8% and 56.1% to 5.90 MJ/Nm3, 87.3% and 62.4%, respectively.

  10. Body temperature change and outcomes in patients undergoing long-distance air medical transport.

    Science.gov (United States)

    Nakajima, Mikio; Aso, Shotaro; Yasunaga, Hideo; Shirokawa, Masamitsu; Nakano, Tomotsugu; Miyakuni, Yasuhiko; Goto, Hideaki; Yamaguchi, Yoshihiro

    2018-04-30

    Short-distance air medical transport for adult emergency patients does not significantly affect patients' body temperature and outcomes. This study aimed to examine the influence of long-distance air medical transport on patients' body temperatures and the relationship between body temperature change and mortality. We retrospectively enrolled consecutive patients transferred via helicopter or plane from isolated islands to an emergency medical center in Tokyo, Japan between April 2010 and December 2016. Patients' average body temperature was compared before and after air transport using a paired t-test, and corrections between body temperature change and flight duration were calculated using Pearson's correlation coefficient. Multivariable logistic regression models were then used to examine the association between body temperature change and in-hospital mortality. Of 1253 patients, the median age was 72 years (interquartile range, 60-82 years) and median flight duration was 71 min (interquartile range, 54-93 min). In-hospital mortality was 8.5%, and average body temperature was significantly different before and after air transport (36.7 °C versus 36.3 °C; difference: -0.36 °C; 95% confidence interval, -0.30 to -0.42; p 38.0 °C) or normothermia (36.0-37.9 °C) before air transport and hypothermia after air transport (odds ratio, 2.08; 95% confidence interval, 1.20-3.63; p = 0.009), and (ii) winter season (odds ratio, 2.15; 95% confidence interval, 1.08-4.27; p = 0.030). Physicians should consider body temperature change during long-distance air transport in patients with not only hypothermia but also normothermia or hyperthermia before air transport, especially in winter. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Allowable spent LWR fuel storage temperatures in inert gases, nitrogen, and air

    International Nuclear Information System (INIS)

    Gilbert, E.R.; Cunningham, M.E.; Simonen, E.P.; Thomas, L.E.; Campbell, T.K.; Barnhart, D.M.

    1990-01-01

    Spent fuel in inert dry storage is now a reality in the US; recommended maximum temperature-time conditions are specified in an IBM PC-compatible code. However, spent fuel cannot yet be stored in air because the data and theory needed for predicting allowable temperatures are still being developed. Tests to determine the behavior of spent UO 2 fragments and breached rod specimens in air are providing data that will be used to determine the temperatures that can be allowed for fuel stored in air. 13 refs., 5 figs

  12. Identifying anthropogenic anomalies in air, surface and groundwater temperatures in Germany.

    Science.gov (United States)

    Benz, Susanne A; Bayer, Peter; Blum, Philipp

    2017-04-15

    Human activity directly influences ambient air, surface and groundwater temperatures. The most prominent phenomenon is the urban heat island effect, which has been investigated particularly in large and densely populated cities. This study explores the anthropogenic impact on the thermal regime not only in selected urban areas, but on a countrywide scale for mean annual temperature datasets in Germany in three different compartments: measured surface air temperature, measured groundwater temperature, and satellite-derived land surface temperature. Taking nighttime lights as an indicator of rural areas, the anthropogenic heat intensity is introduced. It is applicable to each data set and provides the difference between measured local temperature and median rural background temperature. This concept is analogous to the well-established urban heat island intensity, but applicable to each measurement point or pixel of a large, even global, study area. For all three analyzed temperature datasets, anthropogenic heat intensity grows with increasing nighttime lights and declines with increasing vegetation, whereas population density has only minor effects. While surface anthropogenic heat intensity cannot be linked to specific land cover types in the studied resolution (1km×1km) and classification system, both air and groundwater show increased heat intensities for artificial surfaces. Overall, groundwater temperature appears most vulnerable to human activity, albeit the different compartments are partially influenced through unrelated processes; unlike land surface temperature and surface air temperature, groundwater temperatures are elevated in cultivated areas as well. At the surface of Germany, the highest anthropogenic heat intensity with 4.5K is found at an open-pit lignite mine near Jülich, followed by three large cities (Munich, Düsseldorf and Nuremberg) with annual mean anthropogenic heat intensities >4K. Overall, surface anthropogenic heat intensities >0K and

  13. Urban-Rural Temperature Differences in Lagos

    Directory of Open Access Journals (Sweden)

    Vincent N. Ojeh

    2016-05-01

    Full Text Available In this study, the hourly air temperature differences between City hall (urban and Okoafo (rural in Lagos, Nigeria, were calculated using one year of meteorological observations, from June 2014 to May 2015. The two sites considered for this work were carefully selected to represent their climate zones. The city core, City hall, is within the Local Climate Zone (LCZ 2 (Compact midrise while the rural location, Okoafo, falls within LCZ B (Scattered Trees in the south-western part on the outskirt of the city. This study is one of very few to investigate urban temperature conditions in Lagos, the largest city in Africa and one of the most rapidly urbanizing megacities in the world; findings show that maximum nocturnal UHI magnitudes in Lagos can exceed 7 °C during the dry season, and during the rainy season, wet soils in the rural environment supersede regional wind speed as the dominant control over UHI magnitude.

  14. Sleep Apnea and Circadian Extracellular Fluid Change as Independent Factors for Nocturnal Polyuria.

    Science.gov (United States)

    Niimi, Aya; Suzuki, Motofumi; Yamaguchi, Yasuhiro; Ishii, Masaki; Fujimura, Tetsuya; Nakagawa, Tohru; Fukuhara, Hiroshi; Kume, Haruki; Igawa, Yasuhiko; Akishita, Masahiro; Homma, Yukio

    2016-10-01

    We investigated the relationships among nocturnal polyuria, sleep apnea and body fluid volume to elucidate the pathophysiology of nocturia in sleep apnea syndrome. We enrolled 104 consecutive patients who underwent polysomnography for suspected sleep apnea syndrome. Self-assessed symptom questionnaires were administered to evaluate sleep disorder and lower urinary tract symptoms, including nocturia. Voiding frequency and voided volume were recorded using a 24-hour frequency-volume chart. Body fluid composition was estimated in the morning and at night using bioelectric impedance analysis. Frequency-volume chart data were analyzed in 22 patients after continuous positive airway pressure therapy. Patients with nocturnal polyuria showed a higher apnea-hypopnea index (33.9 vs 24.2, p = 0.03) and a larger circadian change in extracellular fluid adjusted to lean body mass (0.22 vs -0.19, p = 0.019) than those without nocturnal polyuria. These relations were more evident in patients 65 years old or older than in those 64 years or younger. A multivariate linear regression model showed an independent relationship of nocturnal polyuria with the apnea-hypopnea index and the circadian change in extracellular fluid adjusted to lean body mass (p = 0.0012 and 0.022, respectively). Continuous positive airway pressure therapy significantly improved nocturnal polyuria and nocturia only in patients with nocturnal polyuria. This study identified sleep apnea and the circadian change in extracellular fluid as independent factors for nocturnal polyuria. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Nocturnal thoracoabdominal asynchrony in house dust mite-sensitive nonhuman primates

    Directory of Open Access Journals (Sweden)

    XiaoJia Wang

    2010-07-01

    Full Text Available XiaoJia Wang, Shaun Reece, Stephen Olmstead, Robert L Wardle, Michael R Van ScottDepartment of Physiology, East Carolina University, Greenville, North Carolina, USAAbstract: Nocturnal bronchoconstriction is a common symptom of asthma in humans, but is poorly documented in animal models. Thoracoabdominal asynchrony (TAA is a noninvasive clinical indication of airway obstruction. In this study, respiratory inductive plethysmography (RIP was used to document nocturnal TAA in house dust mite (HDM-sensitive Cynomolgus macaques. Dynamic compliance (Cdyn and lung resistance (RL measured in anesthetized ­animals at rest and following exposure to HDM allergen, methacholine, and albuterol were highly ­correlated with three RIP parameters associated with TAA, ie, phase angle of the rib cage and abdomen waveforms (PhAng, baseline effort phase relation (eBPRL and effort phase relation (ePhRL. Twenty-one allergic subjects were challenged with HDM early in the morning, and eBPRL and ePhRL were monitored for 20 hours after provocation. Fifteen of the allergic subjects exhibited gradual increases in eBPRL and ePhRL between midnight and 6 am, with peak activity at 4 am. However, as in humans, this nocturnal response was highly variable both between subjects and within subjects over time. The results document that TAA in this nonhuman primate model of asthma is highly correlated with Cdyn and RL, and demonstrate that animals exhibiting acute responses to allergen exposure during the day also exhibit nocturnal TAA.Keywords: nocturnal asthma, late phase asthmatic response, respiratory inductive plethysmography

  16. Nocturnal sleep problems among university students from 26 countries.

    Science.gov (United States)

    Peltzer, Karl; Pengpid, Supa

    2015-05-01

    The aim of this study is to estimate the prevalence of nocturnal sleeping problems and its associated factors among university students in mainly low- and middle-income countries. A cross-sectional survey was conducted with 20,222 undergraduate university students (mean age, 20.8; SD = 2.8) from 27 universities in 26 countries across Asia, Africa and the Americas. Overall, 10.4% reported severe or extreme nocturnal sleeping problems (male, 10.2%; female, 10.5%) in the past month. Noctural sleeping problems differed by country, from 32.9% in Indonesia to 3.0 % in Thailand among Asian countries, from 13.7% in Mauritius to 7.5% in South Africa, and from 11.8% in Jamaica to 6.1% in Columbia in the Americas. In multivariate logistic regression analysis, coming from a poor family background, staying off campus (on their own or with parents or guardians), stress (history of child sexual abuse), poor mental health (depression and PTSD symptoms), health risk behaviour (tobacco use, heavy internet use, gambling, skipping breakfast and having sustained an injury), lack of social support and poor academic performance were associated with nocturnal sleeping problems. A significant prevalence of past-month nocturnal sleeping problems was found. Potential factors associated with the risk of reporting sleeping complaints were identified, which may assist in prevention strategies to promote a better quality of sleep.

  17. Low temperature catalytic combustion of natural gas - hydrogen - air mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Newson, E; Roth, F von; Hottinger, P; Truong, T B [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    The low temperature catalytic combustion of natural gas - air mixtures would allow the development of no-NO{sub x} burners for heating and power applications. Using commercially available catalysts, the room temperature ignition of methane-propane-air mixtures has been shown in laboratory reactors with combustion efficiencies over 95% and maximum temperatures less than 700{sup o}C. After a 500 hour stability test, severe deactivation of both methane and propane oxidation functions was observed. In cooperation with industrial partners, scaleup to 3 kW is being investigated together with startup dynamics and catalyst stability. (author) 3 figs., 3 refs.

  18. Numerical calculation of air velocity and temperature in ice rinks

    Energy Technology Data Exchange (ETDEWEB)

    Bellache, O.; Galanis, N. [Sherbrooke Univ., PQ (Canada); Ouzzane, M.; Sunye, R. [Natural Resources Canada, Varennes, PQ (Canada). CANMET Energy Diversification Laboratory

    2002-07-01

    A computational fluid dynamic (CFD) model was developed to predict the energy consumption at an ice rink. Ice rinks in Canada consume approximately 3500 GWh of electricity annually and generate about 300,000 tons of gases contributing to the greenhouse effect. This newly developed model also considers ice quality and comfort conditions in the arena. The typical 2D configuration includes refrigeration loads as well as heat transfer coefficients between the air and the ice. The effects of heat losses through the ice rink envelope are also determined. A comparison of prediction results from 4 different formulations confirms that there are important differences in air velocities near the walls and in the temperature gradient near the ice. The turbulent mixed convection model gives the best estimate of the refrigeration load. It was determined that a good ventilation should circulate air throughout the building to avoid stagnant areas. Air velocities must be low near the stands where the temperature should be around 20 degrees C. Air temperature near the ice should be low to preserve ice quality and to reduce the refrigeration load. The complexity of this geometry has been taken into account in a numerical simulation of the hydrodynamic and thermal fields in the ice rink. 9 refs., 2 tabs., 5 figs.

  19. Air pollution removal and temperature reduction by Gainesville's urban forest

    Science.gov (United States)

    Francisco Escobedo; Jennifer A. Seitz; Wayne Zipperer

    2009-01-01

    Poor air quality is a common problem in many urban areas. It can lead to human health problems and reduced visibility, and it can impair the health of plants and wildlife. The urban forest can help improve air quality by removing pollutants and by reducing air temperature through shading and transpiration. Trees also emit volatile...

  20. Daily Air Temperature and Electricity Load in Spain.

    Science.gov (United States)

    Valor, Enric; Meneu, Vicente; Caselles, Vicente

    2001-08-01

    Weather has a significant impact on different sectors of the economy. One of the most sensitive is the electricity market, because power demand is linked to several weather variables, mainly the air temperature. This work analyzes the relationship between electricity load and daily air temperature in Spain, using a population-weighted temperature index. The electricity demand shows a significant trend due to socioeconomic factors, in addition to daily and monthly seasonal effects that have been taken into account to isolate the weather influence on electricity load. The results indicate that the relationship is nonlinear, showing a `comfort interval' of ±3°C around 18°C and two saturation points beyond which the electricity load no longer increases. The analysis has also revealed that the sensitivity of electricity load to daily air temperature has increased along time, in a higher degree for summer than for winter, although the sensitivity in the cold season is always more significant than in the warm season. Two different temperature-derived variables that allow a better characterization of the observed relationship have been used: the heating and cooling degree-days. The regression of electricity data on them defines the heating and cooling demand functions, which show correlation coefficients of 0.79 and 0.87, and predicts electricity load with standard errors of estimate of ±4% and ±2%, respectively. The maximum elasticity of electricity demand is observed at 7 cooling degree-days and 9 heating degree-days, and the saturation points are reached at 11 cooling degree-days and 13 heating degree-days, respectively. These results are helpful in modeling electricity load behavior for predictive purposes.

  1. The Relationship Between Child Anxiety Related Disorders and Primary Nocturnal Enuresis.

    Science.gov (United States)

    Salehi, Bahman; Yousefichaijan, Parsa; Rafeei, Mohammad; Mostajeran, Mahssa

    2016-06-01

    Nocturnal enuresis, often called bedwetting or sleep wetting, is a common problem in children after the age of five and may lead to symptoms such as infection, incontinence and frequent urination. This problem refers to a state in which children after the age of five have no control of their urine for six continuous months and it cannot be attributed to any organic factors or drug use. In this study we aimed to study generalized anxiety disorder as one of the possible causes of primary nocturnal enuresis. In this case-control study 180 children with primary nocturnal enuresis and same number of healthy children with a mean age of 7 - 17 years old with the same demographic characteristics were selected. The study took place at Amir Kabir hospital of Arak, Iran during year 2014. After collecting the information, diagnosis was verified based on the diagnostic and statistical manual of mental disorders (DSM) IV-TR criteria. Results were analyzed using the SPSS software (IBM Corp. Released 2011. IBM SPSS Statistics for Windows, version 20.0. Armonk, NY: IBM Corp.). Frequency of generalized anxiety disorder, panic disorder, school phobia, social anxiety, separation anxiety, history of anxiety in mother, history of primary nocturnal enuresis in parent's family and body mass index had a significant difference between the two groups (P = 0.005). With the results obtained from this study we could say that there was a clear significant difference between the two control and patient groups for all subgroups of anxiety disorders such as generalized anxiety disorder and their relationship with primary nocturnal enuresis. Given the higher prevalence of generalized anxiety disorder, panic disorder, school phobia, social anxiety, separation anxiety and comparison with healthy children, it is recommended for all children with primary nocturnal enuresis to be investigated and treated for generalized anxiety disorder.

  2. The nocturnal bottleneck and the evolution of activity patterns in mammals

    Science.gov (United States)

    Gerkema, Menno P.; Davies, Wayne I. L.; Foster, Russell G.; Menaker, Michael; Hut, Roelof A.

    2013-01-01

    In 1942, Walls described the concept of a ‘nocturnal bottleneck’ in placental mammals, where these species could survive only by avoiding daytime activity during times in which dinosaurs were the dominant taxon. Walls based this concept of a longer episode of nocturnality in early eutherian mammals by comparing the visual systems of reptiles, birds and all three extant taxa of the mammalian lineage, namely the monotremes, marsupials (now included in the metatherians) and placentals (included in the eutherians). This review describes the status of what has become known as the nocturnal bottleneck hypothesis, giving an overview of the chronobiological patterns of activity. We review the ecological plausibility that the activity patterns of (early) eutherian mammals were restricted to the night, based on arguments relating to endothermia, energy balance, foraging and predation, taking into account recent palaeontological information. We also assess genes, relating to light detection (visual and non-visual systems) and the photolyase DNA protection system that were lost in the eutherian mammalian lineage. Our conclusion presently is that arguments in favour of the nocturnal bottleneck hypothesis in eutherians prevail. PMID:23825205

  3. Water infiltration in an aquifer recharge basin affected by temperature and air entrapment

    Directory of Open Access Journals (Sweden)

    Loizeau Sébastien

    2017-09-01

    Full Text Available Artificial basins are used to recharge groundwater and protect water pumping fields. In these basins, infiltration rates are monitored to detect any decrease in water infiltration in relation with clogging. However, miss-estimations of infiltration rate may result from neglecting the effects of water temperature change and air-entrapment. This study aims to investigate the effect of temperature and air entrapment on water infiltration at the basin scale by conducting successive infiltration cycles in an experimental basin of 11869 m2 in a pumping field at Crepieux-Charmy (Lyon, France. A first experiment, conducted in summer 2011, showed a strong increase in infiltration rate; which was linked to a potential increase in ground water temperature or a potential dissolution of air entrapped at the beginning of the infiltration. A second experiment was conducted in summer, to inject cold water instead of warm water, and also revealed an increase in infiltration rate. This increase was linked to air dissolution in the soil. A final experiment was conducted in spring with no temperature contrast and no entrapped air (soil initially water-saturated, revealing a constant infiltration rate. Modeling and analysis of experiments revealed that air entrapment and cold water temperature in the soil could substantially reduce infiltration rate over the first infiltration cycles, with respective effects of similar magnitude. Clearly, both water temperature change and air entrapment must be considered for an accurate assessment of the infiltration rate in basins.

  4. Neuro-models for discharge air temperature system

    International Nuclear Information System (INIS)

    Zaheer-uddin, M.; Tudoroiu, N.

    2004-01-01

    Nonlinear neuro-models for a discharge air temperature (DAT) system are developed. Experimental data gathered in a heating ventilating and air conditioning (HVAC) test facility is used to develop multi-input multi-output (MIMO) and single-input single-output (SISO) neuro-models. Several different network architectures were explored to build the models. Results show that a three layer second order neural network structure is necessary to achieve good accuracy of the predictions. Results from the developed models are compared, and some observations on sensitivity and standard deviation errors are presented

  5. Validation of AIRS V6 Surface Temperature over Greenland with GCN and NOAA Stations

    Science.gov (United States)

    Lee, Jae N.; Hearty, Thomas; Cullather, Richard; Nowicki, Sophie; Susskind, Joel

    2016-01-01

    This work compares the temporal and spatial characteristics of the AIRSAMSU (Atmospheric Infrared Sounder Advanced Microwave Sounding Unit A) Version 6 and MODIS (Moderate resolution Imaging Spectroradiometer) Collection 5 derived surface temperatures over Greenland. To estimate uncertainties in space-based surface temperature measurements, we re-projected the MODIS Ice Surface Temperature (IST) to 0.5 by 0.5 degree spatial resolution. We also re-gridded AIRS Skin Temperature (Ts) into the same grid but classified with different cloud conditions and surface types. These co-located data sets make intercomparison between the two instruments relatively straightforward. Using this approach, the spatial comparison between the monthly mean AIRS Ts and MODIS IST is in good agreement with RMS 2K for May 2012. This approach also allows the detection of any long-term calibration drift and the careful examination of calibration consistency in the MODIS and AIRS temperature data record. The temporal correlations between temperature data are also compared with those from in-situ measurements from GC-Net (GCN) and NOAA stations. The coherent time series of surface temperature evident in the correlation between AIRS Ts and GCN temperatures suggest that at monthly time scales both observations capture the same climate signal over Greenland. It is also suggested that AIRS surface air temperature (Ta) can be used to estimate the boundary layer inversion.

  6. Phytoclimatic assessment of air temperatures transition across important Bbundary values

    International Nuclear Information System (INIS)

    Kazandjiev, Valentin; Slavov, Nicola

    2004-01-01

    Thermal regime investigation in global and regional scale is the problem permanently in field of vision of climatologists in the world. Many of investigations abroad and in our country are devoted to discover long time variation, cycles and their periodicity and especially on the registration of air temperatures changes and averages per year, per six months, seasons and months. Great interest is assessment of change of terms for strong air temperatures transition across 0, 5, 10 and 15 o C during spring and autumn seasons, because they have important scientific and practical application i.e. they are the limit between cold and warm part of the year and trace out duration of the vegetative and non vegetative for different bio ecosystems such as phyto ecosystems and zoo ecosystems. For this reason, the interest on the investigation of agro climatic and forest climatic peculiarity of these indicators increase for last few years. This increase is connected with big importance part of nature season's dynamics connected with human economic activity. Increase of air temperature up to 0 o C an transition by this limit certify for change of cold with warm period and beginning of spring; Contrariwise, decrease the temperatures down the 0 o C shows the end of autumn and beginning of winter. In the moderate continental climatic regions, where is classified most big part of Bulgaria territory is observed for seasons - winter, spring, summer and autumn. Climatologists usually accept these seasons with equal duration - three months. This duration of the seasons, do not permit to provide clear assessment of meteorological conditions in connection with development of plant ecosystems and production in different country regions. By this reason, seasons differentiation by agro climatic and forest-climatic point of view is other use the annual course of the air temperatures. As a strong and most suitable way for beginning and end of seasons are air temperatures transitions up and down

  7. The Effect of Temperature and Air Velocity on Drying Kinetics of Pistachio Nuts during Roasting by using Hot Air Flow

    Directory of Open Access Journals (Sweden)

    A Dini

    2017-10-01

    Full Text Available Introduction Pistachio nut is one of the most delicious and nutritious nuts in the world and it is being used as a saltedand roasted product or as an ingredient in snacks, ice cream, desserts, etc. The purpose of roasting is to promote flavour and texture changes in nuts that ultimately increase the overall palatability of the product.Roasting involves a number of physico-chemical changes, including heat exchange, chemical reactions and drying. Knowledge of desorption kinetics is essential to predict the behavior of the material during roasting process and to design roaster equipment.The main aim of this research was to evaluate suitable models for predicting moisture ratio, the effect of air temperature and velocity on the drying kinetics of pistachio nuts and obtain the effective diffusivity coefficient and activation energy in the drying process during the roasting of pistachio nuts. Materials and Methods Dried Ahmadaghaei pistachio nuts were supplied from Kashefan Kavir company (Doraj co. in Rafsanjan. Pistachio nuts were soaked in 17% salt solution for 8 minute and roasting was investigated at air temperatures of 120,130, 145, 160 and 170 °C and air velocities of 0.6, 0.88, 1.3, 1.72 and 2 ms-1. Five semi-theoretical and two empirical kinetic models were fitted to drying experimental data using nonlinear regression analysis techniques in the Curve Expert 2.2 computer program. Results and Discussion Tow-way ANOVA indicated that temperature and hot air velocity significantly affected the drying process during roasting of shelled pistachio nuts. The higher roasting temperatures and air velocities resulted in the higher drying rates. During first 10 min of roasting at constant air velocity of 1.3 ms-1, 64.5%, 70.3%, 77.1%, 83.5%, 89.7% of the moisture were removed at roasting air temperatures of 120 °C, 130 °C, 145 °C, 160 °C, 170 °C, respectively. The high regression coefficients (R2>0.996 and low reduced chi-square (χ2, mean relative

  8. Detonation cell size measurements in high-temperature hydrogen-air-steam mixtures at the BNL high-temperature combustion facility

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsberg, T.; Boccio, J.L.

    1997-11-01

    The High-Temperature Combustion Facility (HTCF) was designed and constructed with the objective of studying detonation phenomena in mixtures of hydrogen-air-steam at initially high temperatures. The central element of the HTCF is a 27-cm inner-diameter, 21.3-m long cylindrical test vessel capable of being heating to 700K ± 14K. A unique feature of the HTCF is the 'diaphragmless' acetylene-oxygen gas driver which is used to initiate the detonation in the test gas. Cell size measurements have shown that for any hydrogen-air-steam mixture, increasing the initial mixture temperature, in the range of 300K to 650K, while maintaining the initial pressure of 0.1 MPa, decreases the cell size and thus makes the mixture more detonable. The effect of steam dilution on cell size was tested in stoichiometric and off-stoichiometric (e.g., equivalence ratio of 0.5) hydrogen-air mixtures. Increasing the steam dilution in hydrogen-air mixtures at 0.1 MPa initial pressure increases the cell size, irrespective of initial temperature. It is also observed that the desensitizing effect of steam diminished with increased initial temperature. A 1-dimensional, steady-state Zel'dovich, von Neumann, Doring (ZND) model, with full chemical kinetics, has been used to predict cell size for hydrogen-air-steam mixtures at different initial conditions. Qualitatively the model predicts the overall trends observed in the measured cell size versus mixture composition and initial temperature and pressure. It was found that the proportionality constant used to predict detonation cell size from the calculated ZND model reaction zone varies between 10 and 100 depending on the mixture composition and initial temperature. 32 refs., 35 figs

  9. Lowland rice yield estimates based on air temperature and solar radiation

    International Nuclear Information System (INIS)

    Pedro Júnior, M.J.; Sentelhas, P.C.; Moraes, A.V.C.; Villela, O.V.

    1995-01-01

    Two regression equations were developed to estimate lowland rice yield as a function of air temperature and incoming solar radiation, during the crop yield production period in Pindamonhangaba, SP, Brazil. The following rice cultivars were used: IAC-242, IAC-100, IAC-101 and IAC-102. The value of optimum air temperature obtained was 25.0°C and of optimum global solar radiation was 475 cal.cm -2 , day -1 . The best agrometeorological model was the one that related least deviation of air temperature and solar radiation in relation to the optimum value obtained through a multiple linear regression. The yield values estimated by the model showed good fit to actual yields of lowland rice (less than 10%). (author) [pt

  10. Effect of melatonin on nocturnal blood pressure: meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Laudon M

    2011-09-01

    Full Text Available Ehud Grossman1,4, Moshe Laudon2, Nava Zisapel2,31Department of Internal Medicine D and Hypertension Unit, The Chaim Sheba Medical Center, Tel-Hashomer, Israel; 2Neurim Pharmaceuticals Ltd, Tel Aviv, Israel and 3Department of Neurobiology, Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel; 4Sackler School of Medicine, Tel Aviv University, Tel Aviv, IsraelBackground: Patients with nocturnal hypertension are at higher risk for cardiovascular complications such as myocardial infarction and cerebrovascular insult. Published studies inconsistently reported decreases in nocturnal blood pressure with melatonin.Methods: A meta-analysis of the efficacy and safety of exogenous melatonin in ameliorating nocturnal blood pressure was performed using a random effects model of all studies fitting the inclusion criteria, with subgroup analysis of fast-release versus controlled-release preparations.Results: Seven trials (three of controlled-release and four of fast-release melatonin with 221 participants were included. Meta-analysis of all seven studies did not reveal significant effects of melatonin versus placebo on nocturnal blood pressure. However, subgroup analysis revealed that controlled-release melatonin significantly reduced nocturnal blood pressure whereas fast-release melatonin had no effect. Systolic blood pressure decreased significantly with controlled-release melatonin (-6.1 mmHg; 95% confidence interval [CI] -10.7 to -1.5; P = 0.009 but not fast-release melatonin (-0.3 mmHg; 95% CI -5.9 to 5.30; P = 0.92. Diastolic blood pressure also decreased significantly with controlled-release melatonin (-3.5 mmHg; 95% CI -6.1 to -0.9; P = 0.009 but not fast-release melatonin (-0.2 mmHg; 95% CI -3.8 to 3.3; P = 0.89. No safety concerns were raised.Conclusion: Add-on controlled-release melatonin to antihypertensive therapy is effective and safe in ameliorating nocturnal hypertension, whereas fast-release melatonin is ineffective. It is necessary

  11. Oxidation characteristics of MgF2 in air at high temperature

    Science.gov (United States)

    Chen, H. K.; Jie, Y. Y.; Chang, L.

    2017-02-01

    High temperature oxidation properties of MgF2 in air were studied. The changes of phase composition, macro surface morphology, weight and elemental composition of MgF2 samples with temperature were investigated by using XRD, EDS and gravimetric analyses. The results show that the oxidation reaction of MgF2 converted to MgO occurred at high temperature, and the reaction was accelerated by the increase of temperature and the presence of impurities. This result clarifies the understanding of the high temperature oxidation behavior of MgF2 in air, and provides a theoretical basis for the reasonable application of MgF2 in optical coating materials, electronic ceramic materials and magnesium melt protection.

  12. Temperature ranges of the application of air-to-air heat recovery ventilator in supermarkets in winter, China

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yanming; Wang, Youjun; Zhong, Ke [School of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China); Liu, Jiaping [School of Architecture, Xi' an University of Architecture and Technology, Xi' an 710055 (China)

    2010-12-15

    Energy consumption is an important issue in China. In heating, ventilation and air conditioning (HVAC) systems, more and more commercial buildings use air-to-air heat recovery ventilators as energy saving units for recovering heat from the exhaust air in ventilation systems in current years. In the present paper, critical temperatures of air-to-air heat recovery systems for supermarkets in winter are recommended and discussed for the four cities in different climate zones of China. The analysis shows that the temperature of fresh air in winter can be categorized into three regions, i.e., recovery region, transition region and impermissible recovery region. The results also indicate that the latent heat recovery is not suitable for ventilation energy savings in supermarkets in winter. Meanwhile, the applicability of sensible heat recovery in supermarkets depends on outdoor climate and fresh air flow rate. If a variable rotational speed fan is used to introduce fresh air into the building, heat recovery does always function as planned in winter for all the selected cities except Guangzhou, and most values of the COP are much higher than 2.5. Otherwise, there is the risk of negative impact on building energy savings in all cities except Harbin. (author)

  13. Detonation cell size measurements and predictions in hydrogen-air-steam mixtures at elevated temperatures

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsberg, T.; Boccio, J.; Economos, C.

    1994-01-01

    The present research reports on the effect of initial mixture temperature on the experimentally measured detonation cell size for hydrogen-air-steam mixtures. Experimental and theoretical research related to combustion phenomena in hydrogen-air-steam mixtures has been ongoing for many years. However, detonation cell size data currently exists or hydrogen-air-steam mixtures up to a temperature of only 400K. Sever accident scenarios have been identified for light water reactors (LWRs) where hydrogen-air mixture temperatures in excess of 400K could be generated within containment. The experiments in this report focus on extending the cell size data base for initial mixture temperatures in excess of 400K. The experiments were carried out in a 10-cm inner-diameter, 6.1-m long heated detonation tube with a maximum operating temperature of 700K and spatial temperature uniformity of ±14K. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air initial gas mixture temperature, in the range 300K--650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The hydrogen-air detonability limits for the 10-cm inside-diameter test vessel, based upon the onset of single-head spin, decreased from 15 percent by hydrogen at 300K down to about 9 percent hydrogen at 650K. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments

  14. Analysis of air temperature and relative humidity: study of microclimates

    OpenAIRE

    Elis Dener Lima Alves; Marcelo Sacardi Biudes

    2012-01-01

    Understanding the variability of climate elements in time and space is fundamental to the knowledge of the dynamics of microclimate. Thus, the objective was to analyze the variability of air temperature and relative humidity on the Cuiabá campus of the Federal University of Mato Grosso, and, through the clustering technique, to analyze the formation of groups to propose a zoning microclimate in the area study. To this end, collection data of air temperature and relative humidity at 15 points ...

  15. The association of air temperature with cardiac arrhythmias

    Science.gov (United States)

    Čulić, Viktor

    2017-11-01

    The body response to meteorological influences may activate pathophysiological mechanisms facilitating the occurrence of cardiac arrhythmias in susceptible patients. Putative underlying mechanisms include changes in systemic vascular resistance and blood pressure, as well as a network of proinflammatory and procoagulant processes. Such a chain reaction probably occurs within the time window of several hours, so use of daily average values of meteorological elements do not seem appropriate for investigation in this area. In addition, overall synoptic situation, and season-specific combinations of meteorological elements and air pollutant levels probably cause the overall effect rather than a single atmospheric element. Particularly strong interrelations have been described among wind speed, air pressure and temperature, relative air humidity, and suspended particulate matter. This may be the main reason why studies examining the association between temperature and ventricular arrhythmias have found linear positive, negative, J-shaped or no association. Further understanding of the pathophysiological adaptation to atmospheric environment may help in providing recommendations for protective measures during "bad" weather conditions in patients with cardiac arrhythmias.

  16. Phytotherapy for children's nocturnal enuresis | Ahmadipour ...

    African Journals Online (AJOL)

    Results have shown that Zingiber officinale, Valeriana officinalis, Alcea rosea, Elettaria cardamomum, Cinnamomum verum, Ribes uva-crispa, Cornus mas, Juglans regia, Vitis vinifera, Sinapis spp., Olea europaea, and Prunus cerasus are a number of important plants that are effective on nocturnal enuresis in traditional ...

  17. Capnography for assessing nocturnal hypoventilation and predicting compliance with subsequent noninvasive ventilation in patients with ALS.

    Directory of Open Access Journals (Sweden)

    Sung-Min Kim

    Full Text Available BACKGROUND: Patients with amyotrophic lateral sclerosis (ALS suffer from hypoventilation, which can easily worsen during sleep. This study evaluated the efficacy of capnography monitoring in patients with ALS for assessing nocturnal hypoventilation and predicting good compliance with subsequent noninvasive ventilation (NIV treatment. METHODS: Nocturnal monitoring and brief wake screening by capnography/pulse oximetry, functional scores, and other respiratory signs were assessed in 26 patients with ALS. Twenty-one of these patients were treated with NIV and had their treatment compliance evaluated. RESULTS: Nocturnal capnography values were reliable and strongly correlated with the patients' respiratory symptoms (R(2 = 0.211-0.305, p = 0.004-0.021. The duration of nocturnal hypercapnea obtained by capnography exhibited a significant predictive power for good compliance with subsequent NIV treatment, with an area-under-the-curve value of 0.846 (p = 0.018. In contrast, no significant predictive values for nocturnal pulse oximetry or functional scores for nocturnal hypoventilation were found. Brief waking supine capnography was also useful as a screening tool before routine nocturnal capnography monitoring. CONCLUSION: Capnography is an efficient tool for assessing nocturnal hypoventilation and predicting good compliance with subsequent NIV treatment of ALS patients, and may prove useful as an adjunctive tool for assessing the need for NIV treatment in these patients.

  18. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    and the horizontal distribution of containment concentration in the breathing zone were measured as the supply air temperature ranged from 15.0°C (59°F)to 19.0°C (66.2°F). The results showed that the vertical air temperature differences were less than 0.3°C (32.5°F) with FH+MV or CH+MV and between 1.9°C (35.4°F...

  19. Air-ground temperature coupling: analysis by means of Thermal Orbits

    Czech Academy of Sciences Publication Activity Database

    Čermák, Vladimír; Bodri, L.

    2016-01-01

    Roč. 6, č. 1 (2016), s. 112-122 ISSN 2160-0414 R&D Projects: GA ČR(CZ) GAP210/11/0183; GA MŠk(CZ) LG13040 Institutional support: RVO:67985530 Keywords : Thermal Orbits * temperature monitoring * air temperature vs ground temperature Subject RIV: DG - Athmosphere Sciences, Meteorology

  20. The impact of temperature and humidity on perception and emission of indoor air pollutants

    DEFF Research Database (Denmark)

    Fang, Lei; Clausen, Geo; Fanger, Povl Ole

    1996-01-01

    Sensory response to air polluted by five building materials under different combinations of temperature and humidity in the ranges 18°C-28°C and 30%-70% was studied in the laboratory. The experiments were designed to study separately the impact of temperature and humidity on the perception of air...... polluted by materials, and on the emission of pollutants from the materials. At all tested pollution levels of the five materials, the air was perceived significantly less acceptable with increasing temperature and humidity, and the impact of temperature and humidity on perception decreased with increasing...... pollution level. A significant linear correlation between acceptability and enthalpy of the air was found to describe the influence of temperature and humidity on perception. The impact of temperature and humidity on sensory emission was less significant than the impact on perception; however, the sensory...

  1. Skin sites to predict deep-body temperature while wearing firefighters' personal protective equipment during periodical changes in air temperature.

    Science.gov (United States)

    Kim, Siyeon; Lee, Joo-Young

    2016-04-01

    The aim of this study was to investigate stable and valid measurement sites of skin temperatures as a non-invasive variable to predict deep-body temperature while wearing firefighters' personal protective equipment (PPE) during air temperature changes. Eight male firefighters participated in an experiment which consisted of 60-min exercise and 10-min recovery while wearing PPE without self-contained breathing apparatus (7.75 kg in total PPE mass). Air temperature was periodically fluctuated from 29.5 to 35.5 °C with an amplitude of 6 °C. Rectal temperature was chosen as a deep-body temperature, and 12 skin temperatures were recorded. The results showed that the forehead and chest were identified as the most valid sites to predict rectal temperature (R(2) = 0.826 and 0.824, respectively) in an environment with periodically fluctuated air temperatures. This study suggests that particular skin temperatures are valid as a non-invasive variable when predicting rectal temperature of an individual wearing PPE in changing ambient temperatures. Practitioner Summary: This study should offer assistance for developing a more reliable indirect indicating system of individual heat strain for firefighters in real time, which can be used practically as a precaution of firefighters' heat-related illness and utilised along with physiological monitoring.

  2. Relative air temperature analysis external building on Gowa Campus

    Science.gov (United States)

    Mustamin, Tayeb; Rahim, Ramli; Baharuddin; Jamala, Nurul; Kusno, Asniawaty

    2018-03-01

    This study aims to data analyze the relative temperature and humidity of the air outside the building. Data retrieval taken from weather monitoring device (monitoring) Vaisala, RTU (Remote Terminal Unit), Which is part of the AWS (Automatic Weather Stations) Then Processing data processed and analyzed by using Microsoft Excel program in the form of graph / picture fluctuation Which shows the average value, standard deviation, maximum value, and minimum value. Results of data processing then grouped in the form: Daily, and monthly, based on time intervals every 30 minutes. The results showed Outside air temperatures in March, April, May and September 2016 Which entered in the thermal comfort zone according to SNI standard (Indonesian National Standard) only at 06.00-10.00. In late March to early April Thermal comfort zone also occurs at 15.30-18.00. The highest maximum air temperature occurred in September 2016 at 11.01-11.30 And the lowest minimum value in September 2016, time 6:00 to 6:30. The result of the next analysis shows the level of data conformity with thermal comfort zone based on SNI (Indonesian National Standard) every month.

  3. Anatomical specializations for nocturnality in a critically endangered parrot, the Kakapo (Strigops habroptilus.

    Directory of Open Access Journals (Sweden)

    Jeremy R Corfield

    Full Text Available The shift from a diurnal to nocturnal lifestyle in vertebrates is generally associated with either enhanced visual sensitivity or a decreased reliance on vision. Within birds, most studies have focused on differences in the visual system across all birds with respect to nocturnality-diurnality. The critically endangered Kakapo (Strigops habroptilus, a parrot endemic to New Zealand, is an example of a species that has evolved a nocturnal lifestyle in an otherwise diurnal lineage, but nothing is known about its' visual system. Here, we provide a detailed morphological analysis of the orbits, brain, eye, and retina of the Kakapo and comparisons with other birds. Morphometric analyses revealed that the Kakapo's orbits are significantly more convergent than other parrots, suggesting an increased binocular overlap in the visual field. The Kakapo exhibits an eye shape that is consistent with other nocturnal birds, including owls and nightjars, but is also within the range of the diurnal parrots. With respect to the brain, the Kakapo has a significantly smaller optic nerve and tectofugal visual pathway. Specifically, the optic tectum, nucleus rotundus and entopallium were significantly reduced in relative size compared to other parrots. There was no apparent reduction to the thalamofugal visual pathway. Finally, the retinal morphology of the Kakapo is similar to that of both diurnal and nocturnal birds, suggesting a retina that is specialised for a crepuscular niche. Overall, this suggests that the Kakapo has enhanced light sensitivity, poor visual acuity and a larger binocular field than other parrots. We conclude that the Kakapo possesses a visual system unlike that of either strictly nocturnal or diurnal birds and therefore does not adhere to the traditional view of the evolution of nocturnality in birds.

  4. A cutoff value based on analysis of a reference population decreases overestimation of the prevalence of nocturnal polyuria.

    Science.gov (United States)

    van Haarst, Ernst P; Bosch, J L H Ruud

    2012-09-01

    We sought criteria for nocturnal polyuria in asymptomatic, nonurological adults of all ages by reporting reference values of the ratio of daytime and nighttime urine volumes, and finding nocturia predictors. Data from a database of frequency-volume charts from a reference population of 894 nonurological, asymptomatic volunteers of all age groups were analyzed. The nocturnal polyuria index and the nocturia index were calculated and factors influencing these values were determined by multivariate analysis. The nocturnal polyuria index had wide variation but a normal distribution with a mean ± SD of 30% ± 12%. The 95th percentile of the values was 53%. Above this cutoff a patient had nocturnal polyuria. This value contrasts with the International Continence Society definition of 33% but agrees with several other reports. On multivariate regression analysis with the nocturnal polyuria index as the dependent variable sleeping time, maximum voided volume and age were the covariates. However, the increase in the nocturnal polyuria index by age was small. Excluding polyuria and nocturia from analysis did not alter the results in a relevant way. The nocturnal voiding frequency depended on sleeping time and maximum voided volume but most of all on the nocturia index. The prevalence of nocturnal polyuria is overestimated. We suggest a new cutoff value for the nocturnal polyuria index, that is nocturnal polyuria exists when the nocturnal polyuria index exceeds 53%. The nocturia index is the best predictor of nocturia. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Air conditioner operation behaviour based on students' skin temperature in a classroom.

    Science.gov (United States)

    Song, Gook-Sup; Lim, Jae-Han; Ahn, Tae-Kyung

    2012-01-01

    A total of 25 college students participated in a study to determine when they would use an air conditioner during a lecture in a university classroom. The ambient temperature and relative humidity were measured 75 cm above the floor every minute. Skin temperatures were measured every minute at seven points, according to the recommendation of Hardy and Dubois. The average clothing insulation value (CLO) of subjects was 0.53 ± 0.07 CLO. The mean air velocity in the classroom was 0.13 ± 0.028 m/s. When the subjects turned the air conditioner both on and off, the average ambient temperatures, relative humidity and mean skin temperatures were 27.4 and 23.7 °C (p = 0.000), 40.9 and 40.0% (p = 0.528) and 32.7 and 32.2 °C (p = 0.024), respectively. When the status of the air conditioner was changed, the differences of skin temperatures in core body parts (head, abdomen and thigh) were not statistically significant. However, in the extremities (mid-lower arm, hand, shin and instep), the differences were statistically significant. Subjects preferred a fluctuating environment to a constant temperature condition. We found that a changing environment does not affect classroom study. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  6. Evaluation of the Global Land Data Assimilation System (GLDAS) air temperature data products

    Science.gov (United States)

    Ji, Lei; Senay, Gabriel B.; Verdin, James P.

    2015-01-01

    There is a high demand for agrohydrologic models to use gridded near-surface air temperature data as the model input for estimating regional and global water budgets and cycles. The Global Land Data Assimilation System (GLDAS) developed by combining simulation models with observations provides a long-term gridded meteorological dataset at the global scale. However, the GLDAS air temperature products have not been comprehensively evaluated, although the accuracy of the products was assessed in limited areas. In this study, the daily 0.25° resolution GLDAS air temperature data are compared with two reference datasets: 1) 1-km-resolution gridded Daymet data (2002 and 2010) for the conterminous United States and 2) global meteorological observations (2000–11) archived from the Global Historical Climatology Network (GHCN). The comparison of the GLDAS datasets with the GHCN datasets, including 13 511 weather stations, indicates a fairly high accuracy of the GLDAS data for daily temperature. The quality of the GLDAS air temperature data, however, is not always consistent in different regions of the world; for example, some areas in Africa and South America show relatively low accuracy. Spatial and temporal analyses reveal a high agreement between GLDAS and Daymet daily air temperature datasets, although spatial details in high mountainous areas are not sufficiently estimated by the GLDAS data. The evaluation of the GLDAS data demonstrates that the air temperature estimates are generally accurate, but caution should be taken when the data are used in mountainous areas or places with sparse weather stations.

  7. Adaptive genomic evolution of opsins reveals that early mammals flourished in nocturnal environments.

    Science.gov (United States)

    Borges, Rui; Johnson, Warren E; O'Brien, Stephen J; Gomes, Cidália; Heesy, Christopher P; Antunes, Agostinho

    2018-02-05

    Based on evolutionary patterns of the vertebrate eye, Walls (1942) hypothesized that early placental mammals evolved primarily in nocturnal habitats. However, not only Eutheria, but all mammals show photic characteristics (i.e. dichromatic vision, rod-dominated retina) suggestive of a scotopic eye design. Here, we used integrative comparative genomic and phylogenetic methodologies employing the photoreceptive opsin gene family in 154 mammals to test the likelihood of a nocturnal period in the emergence of all mammals. We showed that mammals possess genomic patterns concordant with a nocturnal ancestry. The loss of the RH2, VA, PARA, PARIE and OPN4x opsins in all mammals led us to advance a probable and most-parsimonious hypothesis of a global nocturnal bottleneck that explains the loss of these genes in the emerging lineage (> > 215.5 million years ago). In addition, ancestral character reconstruction analyses provided strong evidence that ancestral mammals possessed a nocturnal lifestyle, ultra-violet-sensitive vision, low visual acuity and low orbit convergence (i.e. panoramic vision). Overall, this study provides insight into the evolutionary history of the mammalian eye while discussing important ecological aspects of the photic paleo-environments ancestral mammals have occupied.

  8. Childhood nocturnal enuresis in the Netherlands

    NARCIS (Netherlands)

    Spee-van der Wekke, J.; Hirasing, R.A.; Meulmeester, J.F.; Radder, J.J.

    1998-01-01

    Objectives. To assess the prevalence of nocturnal enuresis in school children aged 5 to 15 years, and to investigate the association of bedwetting with ethnicity, the educational level of the parents, and the type of education (mainstream or special) received by the child. Methods. Data were

  9. Investigation of Breakpoint and Trend of Daily Air Temperature Range for Mashhad, Iran

    Directory of Open Access Journals (Sweden)

    shideh shams

    2017-01-01

    Full Text Available Introduction: Air temperature as an important climatic factor can influence variability and distribution of other climatic parameters. Therefore, tracking the changes in air temperature is a popular procedure in climate change studies.. According to the national academy in the last decade, global temperature has raised 0.4 to 0.8⁰C. Instrumental records show that, with the exception of 1998, the 10 warmest year (during the last 150 years, occurred since 2000, and 2014 was the warmest year. Investigation of maximum and minimum air temperature temporal trend indicates that these two parameters behave differently over time. It has been shown that the minimum air temperature raises noticeably more than the maximum air temperature, which causes a reduction in the difference of maximum and minimum daily air temperature (daily temperature range, DTR. There are several factors that have an influence on reducing DTR such as: Urban development, farms’ irrigation and desertification. It has been shown that DTR reduction occurs mostly during winter and is less frequent during summer, which shows the season’s effect on the temperature trend. Considering the significant effects of the climatological factors on economic and agricultural management issues, the aim of this study is to investigate daily air temperature range for yearly, seasonal and monthly time scales, using available statistical methods. Materials and Methods: Daily maximum and minimum air temperature records (from 1950 to 2010 were obtained from Mashhad Meteorological Organization. In order to control the quality of daily Tmax and Tmin data, four different types of quality controls were applied. First of all, gross errors were checked. In this step maximum and minimum air temperature data exceeding unlikely air temperature values, were eliminated from data series. Second, data tolerance was checked by searching for periods longer than a certain number of consecutive days with exactly the

  10. High-temperature hydrogen-air-steam detonation experiments in the BNL small-scale development apparatus

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsburg, T.; Boccio, J.; Economos, C.; Finfrock, C.; Gerlach, L.; Sato, K.; Kinoshita, M.

    1994-08-01

    The Small-Scale Development Apparatus (SSDA) was constructed to provide a preliminary set of experimental data to characterize the effect of temperature on the ability of hydrogen-air-steam mixtures to undergo detonations and, equally important, to support design of the larger scale High-Temperature Combustion Facility (HTCF) by providing a test bed for solution of a number of high-temperature design and operational problems. The SSDA, the central element of which is a 10-cm inside diameter, 6.1-m long tubular test vessel designed to permit detonation experiments at temperatures up to 700K, was employed to study self-sustained detonations in gaseous mixtures of hydrogen, air, and steam at temperatures between 300K and 650K at a fixed initial pressure of 0.1 MPa. Hydrogen-air mixtures with hydrogen composition from 9 to 60 percent by volume and steam fractions up to 35 percent by volume were studied for stoichiometric hydrogen-air-steam mixtures. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air gas mixture temperature, in the range 300K-650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The hydrogen-air detonability limits for the 10-cm inside diameter SSDA test vessel, based upon the onset of single-head spin, decreased from 15 percent hydrogen at 300K down to between 9 and 10 percent hydrogen at 650K. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments

  11. Prognostic value of nocturnal pulse oximetry in patients with heart failure.

    Science.gov (United States)

    Rivera-López, Ricardo; Jordán-Martínez, Laura; López-Fernández, Silvia; Rivera-Fernandez, Ricardo; Tercedor, Luis; Sáez-Roca, Germán

    2018-05-23

    To analyze the prognostic value of nocturnal hypoxemia measured with portable nocturnal pulse-oximetry in patients hospitalized due to heart failure and its relation to mortality and hospital readmission. We included 38 patients who were admitted consecutively to our unit with the diagnosis of decompensated heart failure. Pulse-oximetry was considered positive for hypoxemia when more than 10 desaturations per hour were recorded during sleep. Follow-up was performed for 30.3 (standard deviation [SD] 14.2) months, the main objective being a combined endpoint of all-cause mortality and hospital readmission due to heart failure. The average age was 70.7 (SD 10.7) years, 63.3% were males. Pulse-oximetry was considered positive for hypoxemia in 27 (71%) patients. Patients with positive pulse-oximetry had the most frequent endpoint (9.1% [1] vs. 61.5% [16], P = 0.003). After multivariate analysis, continuous nocturnal hypoxemia was related to the combined endpoint (HR = 8.37, 1.19-68.4, P = 0.03). Patients hospitalized for heart failure and nocturnal hypoxemia measured with portable pulse-oximeter have an increased risk of hospital readmission and death. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  12. Prevalence of Nocturnal Enuresis and Its Associated Factors in Primary School and Preschool Children of Khorramabad in 2013

    Directory of Open Access Journals (Sweden)

    Katayoun Bakhtiar

    2014-01-01

    Full Text Available Background. Nocturnal enuresis refers to an inability to control urination during sleep. This study aimed to determine the prevalence of nocturnal enuresis and its associated factors in children in the city of Khorramabad. Materials and Methods. In this descriptive-analytic, cross-sectional study, 710 male and female children were divided into two groups with equal numbers. The samples were selected from the schools of Khorramabad using the multistage cluster and stratified random sampling methods based on the diagnostic criteria of DSM-IV. The data was analyzed using the logistic regression. Results. The results showed that 8% of the children had nocturnal enuresis, including 5.2% of primary nocturnal enuresis and 2.8% of secondary nocturnal enuresis. The prevalence of nocturnal enuresis in the boys (10.7% was higher compared with that in the girls (5.4% (P=0.009. There were statistically significant relationships between nocturnal enuresis and history of nocturnal enuresis in siblings (P=0.023, respiratory infections (P=0.036, deep sleep (P=0.007, corporal punishment at school (P=0.036, anal itching (P=0.043, and history of seizures (P=0.043. Conclusion. This study showed that the prevalence of nocturnal enuresis in the boys was higher compared with that in the girls.

  13. Prevalence of nocturnal enuresis and its associated factors in primary school and preschool children of khorramabad in 2013.

    Science.gov (United States)

    Bakhtiar, Katayoun; Pournia, Yadollah; Ebrahimzadeh, Farzad; Farhadi, Ali; Shafizadeh, Fathollah; Hosseinabadi, Reza

    2014-01-01

    Background. Nocturnal enuresis refers to an inability to control urination during sleep. This study aimed to determine the prevalence of nocturnal enuresis and its associated factors in children in the city of Khorramabad. Materials and Methods. In this descriptive-analytic, cross-sectional study, 710 male and female children were divided into two groups with equal numbers. The samples were selected from the schools of Khorramabad using the multistage cluster and stratified random sampling methods based on the diagnostic criteria of DSM-IV. The data was analyzed using the logistic regression. Results. The results showed that 8% of the children had nocturnal enuresis, including 5.2% of primary nocturnal enuresis and 2.8% of secondary nocturnal enuresis. The prevalence of nocturnal enuresis in the boys (10.7%) was higher compared with that in the girls (5.4%) (P = 0.009). There were statistically significant relationships between nocturnal enuresis and history of nocturnal enuresis in siblings (P = 0.023), respiratory infections (P = 0.036), deep sleep (P = 0.007), corporal punishment at school (P = 0.036), anal itching (P = 0.043), and history of seizures (P = 0.043). Conclusion. This study showed that the prevalence of nocturnal enuresis in the boys was higher compared with that in the girls.

  14. Temperature and concentration transients in the aluminum-air battery

    Science.gov (United States)

    Homsy, R. V.

    1981-08-01

    Coupled conservation equations of heat and mass transfer are solved that predict temperature and concentration of the electrolyte of an aluminum-air battery system upon start-up and shutdown. Results of laboratory studies investigating the crystallization kinetics and solubility of the caustic-aluminate electrolyte system are used in the predictions. Temperature and concentration start-up transients are short, while during standby conditions, temperature increases to maximum and decreases slowly.

  15. Innovative Visualizations Shed Light on Avian Nocturnal Migration.

    Directory of Open Access Journals (Sweden)

    Judy Shamoun-Baranes

    Full Text Available Globally, billions of flying animals undergo seasonal migrations, many of which occur at night. The temporal and spatial scales at which migrations occur and our inability to directly observe these nocturnal movements makes monitoring and characterizing this critical period in migratory animals' life cycles difficult. Remote sensing, therefore, has played an important role in our understanding of large-scale nocturnal bird migrations. Weather surveillance radar networks in Europe and North America have great potential for long-term low-cost monitoring of bird migration at scales that have previously been impossible to achieve. Such long-term monitoring, however, poses a number of challenges for the ornithological and ecological communities: how does one take advantage of this vast data resource, integrate information across multiple sensors and large spatial and temporal scales, and visually represent the data for interpretation and dissemination, considering the dynamic nature of migration? We assembled an interdisciplinary team of ecologists, meteorologists, computer scientists, and graphic designers to develop two different flow visualizations, which are interactive and open source, in order to create novel representations of broad-front nocturnal bird migration to address a primary impediment to long-term, large-scale nocturnal migration monitoring. We have applied these visualization techniques to mass bird migration events recorded by two different weather surveillance radar networks covering regions in Europe and North America. These applications show the flexibility and portability of such an approach. The visualizations provide an intuitive representation of the scale and dynamics of these complex systems, are easily accessible for a broad interest group, and are biologically insightful. Additionally, they facilitate fundamental ecological research, conservation, mitigation of human-wildlife conflicts, improvement of meteorological

  16. Nocturnal hypoxia in ALS is related to cognitive dysfunction and can occur as clusters of desaturations.

    Directory of Open Access Journals (Sweden)

    Su-Yeon Park

    Full Text Available Amyotrophic lateral sclerosis (ALS is a neurodegenerative disease that leads to progressive weakness of the respiratory and limb muscles. Consequently, most patients with ALS exhibit progressive hypoventilation, which worsens during sleep. The aim of this study was to evaluate the relationship between nocturnal hypoxia and cognitive dysfunction and to assess the pattern of nocturnal hypoxia in patients with ALS.Twenty-five patients with definite or probable ALS underwent neuropsychologic testing, nocturnal pulse oximetry, and capnography. Patients were grouped according to the presence of nocturnal hypoxia (SpO2<95% for ≥10% of the night and their clinical characteristics and cognitive function were compared.Compared to patients without nocturnal hypoxia, those with nocturnal hypoxia (n = 10, 40% had poor memory retention (p = 0.039 and retrieval efficiency (p = 0.045. A cluster-of-desaturation pattern was identified in 7 patients (70% in the Hypoxia Group.These results suggest that nocturnal hypoxia can be related to cognitive dysfunction in ALS. In addition, a considerable number of patients with ALS may be exposed to repeated episodes of deoxygenation-reoxygenation (a cluster-of-desaturation pattern during sleep, which could be associated with the generation of reactive oxygen species. Further studies are required to define the exact causal relationships between these phenomena, the exact manifestations of nocturnal cluster-of-desaturation patterns, and the effect of clusters of desaturation on ALS progression.

  17. Impact of ambient air temperature and heat load variation on the performance of air-cooled heat exchangers in propane cycles in LNG plants – Analytical approach

    International Nuclear Information System (INIS)

    Fahmy, M.F.M.; Nabih, H.I.

    2016-01-01

    Highlights: • An analytical method regulated the air flow rate in an air-cooled heat exchanger. • Performance of an ACHE in a propane cycle in an LNG plant was evaluated. • Summer inlet air temperature had higher impact on ACHE air flow rate requirement. - Abstract: An analytical method is presented to evaluate the air flow rate required in an air-cooled heat exchanger used in a propane pre-cooling cycle operating in an LNG (liquefied natural gas) plant. With variable ambient air inlet temperature, the air flow rate is to be increased or decreased so as to assure and maintain good performance of the operating air-cooled heat exchanger at the designed parameters and specifications. This analytical approach accounts for the variations in both heat load and ambient air inlet temperature. The ambient air inlet temperature is modeled analytically by simplified periodic relations. Thus, a complete analytical method is described so as to manage the problem of determining and accordingly regulate, either manually or automatically, the flow rate of air across the finned tubes of the air-cooled heat exchanger and thus, controls the process fluid outlet temperature required for the air-cooled heat exchangers for both cases of constant and varying heat loads and ambient air inlet temperatures. Numerical results are obtained showing the performance of the air-cooled heat exchanger of a propane cycle which cools both NG (natural gas) and MR (mixed refrigerant) streams in the LNG plant located at Damietta, Egypt. The inlet air temperature variation in the summer time has a considerable effect on the required air mass flow rate, while its influence becomes relatively less pronounced in winter.

  18. Nocturnal activity patterns of northern myotis (Myotis septentrionalis) during the maternity season in West Virginia (USA)

    Science.gov (United States)

    Johnson, J.B.; Edwards, J.W.; Ford, W.M.

    2011-01-01

    Nocturnal activity patterns of northern myotis (Myotis septentrionalis) at diurnal roost trees remain largely uninvestigated. For example, the influence of reproductive status, weather, and roost tree and surrounding habitat characteristics on timing of emergence, intra-night activity, and entrance at their roost trees is poorly known. We examined nocturnal activity patterns of northern myotis maternity colonies during pregnancy and lactation at diurnal roost trees situated in areas that were and were not subjected to recent prescribed fires at the Fernow Experimental Forest, West Virginia from 2007 to 2009. According to exit counts and acoustic data, northern myotis colony sizes were similar between reproductive periods and roost tree settings. However, intra-night activity patterns differed slightly between reproductive periods and roost trees in burned and non-burned areas. Weather variables poorly explained variation in activity patterns during pregnancy, but precipitation and temperature were negatively associated with activity patterns during lactation. ?? Museum and Institute of Zoology PAS.

  19. Nocturnal Polyuria in Older Women with Urge Urinary Incontinence: Role of Sleep Quality, Time in Bed and Medications Used.

    Science.gov (United States)

    Tyagi, Shachi; Perera, Subashan; Clarkson, Becky D; Tadic, Stasa D; Resnick, Neil M

    2017-03-01

    Nocturia is common and bothersome in older adults, especially those who are also incontinent. Since nocturnal polyuria is a major contributor, we examined factors associated with nocturnal polyuria in this population to identify those possibly amenable to intervention. We analyzed baseline data from 2 previously completed studies of urge urinary incontinence. The studies involved 284 women (mean age ± SD 72.9 ± 7.9 years) who also completed 3-day voiding diaries. Participants with a nocturnal polyuria index greater than 33% were categorized as having nocturnal polyuria (nocturnal polyuria index = nocturnal urinary volume per 24-hour urine volume). Associations between nocturnal polyuria and various demographic, clinical and sleep related parameters were determined. Overall 55% of the participants had nocturnal polyuria. Multivariable regression analysis revealed that age, body mass index, use of angiotensin converting enzyme inhibitor/angiotensin receptor blocker, time spent in bed and duration of first uninterrupted sleep were independent correlates of nocturnal polyuria. Participants with a larger nocturnal excretion reported a shorter duration of uninterrupted sleep before first awakening to void and worse sleep quality despite spending similar time in bed. Body mass index, use of angiotensin converting enzyme inhibitor/angiotensin receptor blockers, time in bed and duration of uninterrupted sleep before first awakening to void are independently associated with nocturnal polyuria in older women with urge urinary incontinence, and are potentially modifiable. These findings also confirm the association between sleep and nocturnal polyuria. Further studies should explore whether interventions to reduce nocturnal polyuria and/or increase the duration of uninterrupted sleep before first awakening to void would help to improve sleep quality in this population and thereby reduce or eliminate the need for sedative hypnotics. Copyright © 2017 American Urological

  20. The Effectiveness of Silodosin for Nocturnal Polyuria in Elderly Men With Benign Prostatic Hyperplasia: A Multicenter Study

    OpenAIRE

    Kim, Young Won; Park, Jinsung; Chung, Hong; Kim, Hong-Wook; Kim, Hyung Joon; Jung, Jae Hung; Kim, Won Tae

    2015-01-01

    Purpose: To investigate improvement in nocturia and nocturnal polyuria in nocturnal polyuria patients after silodosin administration by using a 3-day frequency volume chart. Methods: This was a prospective multicenter study. We enrolled nocturnal polyuria patients (nocturnal polyuria index [NPi]>0.33), aged ≥60 years, diagnosed with the 3-day frequency volume charts of patients with benign prostatic hyperplasia taking α-blockers. Of the 54 patients, 30 (55.6%) completed the study according to...

  1. The association between nocturia and nocturnal polyuria in clinical and epidemiological studies: a systematic review and meta-analyses.

    Science.gov (United States)

    Hofmeester, Ilse; Kollen, Boudewijn J; Steffens, Martijn G; Bosch, J L H Ruud; Drake, Marcus J; Weiss, Jeffrey P; Blanker, Marco H

    2014-04-01

    We determined the relationship between nocturia and nocturnal polyuria. The PubMed® and Embase® databases were searched for studies written in English, German, French or Dutch with original data on adult participants in an investigation of the relationship between nocturia and nocturnal polyuria. A meta-analysis of the difference in mean nocturnal voiding frequencies between patients with and without nocturnal polyuria was conducted. Nocturnal polyuria risk was compared between participants with and without nocturia, and the resulting odds ratio was subsequently converted to relative risk with 95% CIs. From 511 references identified we selected 78 publications of 66 studies, 15 of which met the inclusion criteria for this study. Quality scores of studies were generally high for internal validity but low for external validity. In 7 studies (1,416 participants) we estimated a standardized mean difference of 0.59 (95% CI 0.29-0.89) for nocturnal voids between nocturnal polyuria and nonnocturnal polyuria cases. In 8 other studies (with 2,320 participants) we calculated a pooled OR of 4.99 (3.92-6.37) for nocturnal polyuria in individuals with nocturia. The corresponding RR, based on a nocturnal polyuria risk in the pooled population of 63.8%, was 1.41 (1.37-1.44). The association between nocturia and nocturnal polyuria is apparent and robust. However, the clinical importance of the association appears to be less obvious than previously suggested based on single studies. The observed high prevalence of nocturnal polyuria, as a result of the applied International Continence Society definition, may be responsible for this discrepancy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. The relationship between radiant heat, air temperature and thermal comfort at rest and exercise.

    Science.gov (United States)

    Guéritée, Julien; Tipton, Michael J

    2015-02-01

    The aims of the present work were to investigate the relationships between radiant heat load, air velocity and body temperatures with or without coincidental exercise to determine the physiological mechanisms that drive thermal comfort and thermoregulatory behaviour. Seven male volunteers wearing swimming trunks in 18°C, 22°C or 26°C air were exposed to increasing air velocities up to 3 m s(-1) and self-adjusted the intensity of the direct radiant heat received on the front of the body to just maintain overall thermal comfort, at rest or when cycling (60 W, 60 rpm). During the 30 min of the experiments, skin and rectal temperatures were continuously recorded. We hypothesized that mean body temperature should be maintained stable and the intensity of the radiant heat and the mean skin temperatures would be lower when cycling. In all conditions, mean body temperature was lower when facing winds of 3 m s(-1) than during the first 5 min, without wind. When facing winds, in all but the 26°C air, the radiant heat was statistically higher at rest than when exercising. In 26°C air mean skin temperature was lower at rest than when exercising. No other significant difference was observed. In all air temperatures, high correlation coefficients were observed between the air velocity and the radiant heat load. Other factors that we did not measure may have contributed to the constant overall thermal comfort status despite dropping mean skin and body temperatures. It is suggested that the allowance to behaviourally adjust the thermal environment increases the tolerance of cold discomfort. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. ARIMA representation for daily solar irradiance and surface air temperature time series

    Science.gov (United States)

    Kärner, Olavi

    2009-06-01

    Autoregressive integrated moving average (ARIMA) models are used to compare long-range temporal variability of the total solar irradiance (TSI) at the top of the atmosphere (TOA) and surface air temperature series. The comparison shows that one and the same type of the model is applicable to represent the TSI and air temperature series. In terms of the model type surface air temperature imitates closely that for the TSI. This may mean that currently no other forcing to the climate system is capable to change the random walk type variability established by the varying activity of the rotating Sun. The result should inspire more detailed examination of the dependence of various climate series on short-range fluctuations of TSI.

  4. Local characteristics of the nocturnal boundary layer in response to external pressure forcing

    NARCIS (Netherlands)

    van der Linden, S.J.A.; Baas, P.; van Hooft, J.A.; van Hooijdonk, I.G.S.; Bosveld, F.C.; van de Wiel, B.J.H.

    2017-01-01

    Geostrophic wind speed data, derived from pressure observations, are used in combination with tower measurements to investigate the nocturnal stable boundary layer at Cabauw (The Netherlands). Since the geostrophic wind speed is not directly influenced by local nocturnal stability, it may be

  5. Interactive short-term effects of equivalent temperature and air pollution on human mortality in Berlin and Lisbon

    International Nuclear Information System (INIS)

    Burkart, Katrin; Canário, Paulo; Breitner, Susanne; Schneider, Alexandra; Scherber, Katharina; Andrade, Henrique; Alcoforado, Maria João; Endlicher, Wilfried

    2013-01-01

    There is substantial evidence that both temperature and air pollution are predictors of mortality. Thus far, few studies have focused on the potential interactive effects between the thermal environment and different measures of air pollution. Such interactions, however, are biologically plausible, as (extreme) temperature or increased air pollution might make individuals more susceptible to the effects of each respective predictor. This study investigated the interactive effects between equivalent temperature and air pollution (ozone and particulate matter) in Berlin (Germany) and Lisbon (Portugal) using different types of Poisson regression models. The findings suggest that interactive effects exist between air pollutants and equivalent temperature. Bivariate response surface models and generalised additive models (GAMs) including interaction terms showed an increased risk of mortality during periods of elevated equivalent temperatures and air pollution. Cold effects were mostly unaffected by air pollution. The study underscores the importance of air pollution control in mitigating heat effects. -- Highlights: • Interactive effects between air pollution and equivalent temperature result in augmented excess mortality. • High levels of ozone and particulate matter increase adverse heat effects on human mortality. • Cold effects are mostly unaffected by air pollution. • Findings underscore the importance of air pollution control in mitigating heat-related mortality. -- Interactive effects between air pollution and elevated (equivalent) temperatures underscore the importance of air pollution control in mitigating the adverse effects of heat

  6. Temperature Control of Heating Zone for Drying Process: Effect of Air Velocity Change

    Directory of Open Access Journals (Sweden)

    Wutthithanyawat Chananchai

    2016-01-01

    Full Text Available This paper proposes a temperature control technique to adjust air temperature in a heating zone for drying process. The controller design is achieved by using an internal model control (IMC approach. When the IMC controller parameters were designed by calculating from an actual process transfer function estimated through an open-loop step response with input step change from 50% to 60% at a reference condition at air velocity of 1.20 m/s, the performance of temperature controller was experimentally tested by varying an air velocity between 1.32 m/s and 1.57 m/s, respectively. The experimental results showed that IMC controller had a high competency for controlling the drying temperature.

  7. Surface Layer Processes And Nocturnal Low Level Jet Development--An Observational Study During Pecan

    Science.gov (United States)

    2016-12-01

    temperature was measured at -0.05m, -0.10m, and -0.25m and soil moisture at -0.10m and -0.25m. Shortwave solar irradiance and exitance measurements and...evolution, as found in the second column. This quantity is intended to serve as a measurement of the relative intensity of the LLJ wind maximum to a... measure of turbulence intensity relative to the ambient mean 6 m wind speed during the afternoon hours prior to the onset of the stable nocturnal

  8. NOAA NOS SOS, EXPERIMENTAL, 1853-present, Air Temperature

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA NOS SOS server is part of the IOOS DIF SOS Project. The stations in this dataset have air temperature data. *These services are for testing and evaluation...

  9. Symmetric scaling properties in global surface air temperature anomalies

    Science.gov (United States)

    Varotsos, Costas A.; Efstathiou, Maria N.

    2015-08-01

    We have recently suggested "long-term memory" or internal long-range correlation within the time-series of land-surface air temperature (LSAT) anomalies in both hemispheres. For example, an increasing trend in the LSAT anomalies is followed by another one at a different time in a power-law fashion. However, our previous research was mainly focused on the overall long-term persistence, while in the present study, the upward and downward scaling dynamics of the LSAT anomalies are analysed, separately. Our results show that no significant fluctuation differences were found between the increments and decrements in LSAT anomalies, over the whole Earth and over each hemisphere, individually. On the contrary, the combination of land-surface air and sea-surface water temperature anomalies seemed to cause a departure from symmetry and the increments in the land and sea surface temperature anomalies appear to be more persistent than the decrements.

  10. Perceiving nasal patency through mucosal cooling rather than air temperature or nasal resistance.

    Directory of Open Access Journals (Sweden)

    Kai Zhao

    Full Text Available Adequate perception of nasal airflow (i.e., nasal patency is an important consideration for patients with nasal sinus diseases. The perception of a lack of nasal patency becomes the primary symptom that drives these patients to seek medical treatment. However, clinical assessment of nasal patency remains a challenge because we lack objective measurements that correlate well with what patients perceive. The current study examined factors that may influence perceived patency, including air temperature, humidity, mucosal cooling, nasal resistance, and trigeminal sensitivity. Forty-four healthy subjects rated nasal patency while sampling air from three facial exposure boxes that were ventilated with untreated room air, cold air, and dry air, respectively. In all conditions, air temperature and relative humidity inside each box were recorded with sensors connected to a computer. Nasal resistance and minimum airway cross-sectional area (MCA were measured using rhinomanometry and acoustic rhinometry, respectively. General trigeminal sensitivity was assessed through lateralization thresholds to butanol. No significant correlation was found between perceived patency and nasal resistance or MCA. In contrast, air temperature, humidity, and butanol threshold combined significantly contributed to the ratings of patency, with mucosal cooling (heat loss being the most heavily weighted predictor. Air humidity significantly influences perceived patency, suggesting that mucosal cooling rather than air temperature alone provides the trigeminal sensation that results in perception of patency. The dynamic cooling between the airstream and the mucosal wall may be quantified experimentally or computationally and could potentially lead to a new clinical evaluation tool.

  11. Improving Forecast Skill by Assimilation of Quality Controlled AIRS Version 5 Temperature Soundings

    Science.gov (United States)

    Susskind, Joel; Reale, Oreste

    2009-01-01

    The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 micron CO2 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 micron CO2 observations are now used primarily in the generation of cloud cleared radiances R(sub i). This approach allows for the generation of accurate values of R(sub i) and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by-channel error estimates for R(sub i). These error estimates are used for Quality Control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of Quality Control using the NASA GEOS-5 data assimilation system. Assimilation of Quality Controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done operationally by ECMWF and NCEP. Forecast resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.

  12. Children with monosymptomatic primary nocturnal enuresis – the clinical profile of patients during the first nephrological consultation

    Directory of Open Access Journals (Sweden)

    Anna Krakowska

    2017-12-01

    Full Text Available Introduction: Nocturnal enuresis can be diagnosed in a child older than 5 years of age who involuntarily discharges urine in the wrong time, i.e. at night, and in the wrong place, i.e. in bed. Aim: The aim of the study was to analyse the profile of patients who consult the specialist physician with monosymptomatic primary nocturnal enuresis. Material and methods: The data were collected from a questionnaire completed by guardians of children during the first nephrological consultation. The questions concerned the following: family history of nocturnal enuresis, bedwetting intensity, other urinary tract symptoms, a voiding chart and fluid intake record, number of nocturnal enuresis incidents in 14 days, episodes of nocturia, nocturnal diuresis volume, urinary urgency volume and constipation. Moreover, basic anthropometric measurements were taken. The data were analysed and the following values were calculated: average voided volumes, maximum voided volumes, voided volumes before 5 p.m. and 24-hour diuresis. An analogous analysis was conducted with respect to fluid intake. Results: Most patients were males. The family history of nocturnal enuresis was positive in ⅓ of patients. Approximately ⅓ of patients tended to drink fluids directly before bedtime. The number of patients with sporadic nocturnal enuresis (23–45% was comparable to the number of patients with frequent nocturnal enuresis (28–55%. Nocturnal diuresis suggested nocturnal polyuria in 11 patients (21.6%. Decreased functional bladder capacity was found in almost ¼ of patients (12–23.5%. Conclusions: Monosymptomatic nocturnal enuresis is more common in boys. The family history was positive in ⅓ of patients. Patients and their guardians are not aware of fluid intake restrictions at bedtime. The frequency of nocturnal polyuria and decreased functional bladder capacity is comparable in the investigated patients.

  13. Notes on the ecology of Phyllodactylus reissi (Phyllodactylidae: Sauria in Parque Nacional Cerros de Amotape (Tumbes, Peru

    Directory of Open Access Journals (Sweden)

    Juan Carlos Jordán Arizmendi

    2012-02-01

    Full Text Available Some basics aspects on the ecology of the nocturnal gecko Phyllodactylus reissi from Parque Nacional Cerros de Amotape (Tumbes, Peru are described. This species used rock boulders (57,4% and trees (31,9% as microhabitats primarily, exhibiting a nocturnal activity pattern, with a peak between 2100-2200 hours, remaining active until midnight. Body temperature (mean 24,4 ºC was correlated with both air and substrate temperature, with the last variable affecting in higher degree (47% the body temperature of this species. The slightly high body temperature of Phyllodactylus reissi, compared to other Phyllodactylus geckos, could be related to nocturnal microhabitat use and diurnal retreat site selection. More studies on lizard ecology from this endangered ecosystem are needed.

  14. Modeling validation and control analysis for controlled temperature and humidity of air conditioning system.

    Science.gov (United States)

    Lee, Jing-Nang; Lin, Tsung-Min; Chen, Chien-Chih

    2014-01-01

    This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14 °C, 0006 kg(w)/kg(da) in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

  15. Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Jing-Nang Lee

    2014-01-01

    Full Text Available This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14°C, 0006 kgw/kgda in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

  16. Effect of Nocturnal Haemodialysis on Body Composition

    NARCIS (Netherlands)

    Ipema, K.J.R.; Westerhuis, R.; van der Schans, C.P.; de Jong, P.E.; Gaillard, C.A. J. M.; Krijnen, W.P.; Slart, R.H.J.A.; Franssen, C.F.M.

    2014-01-01

    Background: Haemodialysis patients have a high risk of malnutrition which is associated with increased mortality. Nocturnal haemodialysis (NHD) is associated with a significant increase in protein intake compared with conventional haemodialysis (CHD). It is unclear whether this leads to improved

  17. Modeling skin temperature to assess the effect of air velocity to mitigate heat stress among growing pigs

    DEFF Research Database (Denmark)

    Bjerg, Bjarne; Pedersen, Poul; Morsing, Svend

    2017-01-01

    It is generally accepted that increased air velocity can help to mitigate heat stress in livestock housing, however, it is not fully clear how much it helps and significant uncertainties exists when the air temperature approaches the animal body temperature. This study aims to develop a skin...... temperature model to generated data for determining the potential effect of air velocity to mitigate heat stress among growing pigs housed in warm environment. The model calculates the skin temperature as function of body temperature, air temperature and the resistances for heat transfer from the body...

  18. Temperature Anomalies from the AIRS Product in Giovanni for the Climate Community

    Science.gov (United States)

    Ding, Feng; Hearty, Thomas J.; Wei, Jennifer; Theobald, Michael; Vollmer, Bruce; Seiler, Edward; Meyer, David

    2018-01-01

    The Atmospheric Infrared Sounder (AIRS) mission began with the launch of Aqua in 2002. Over 15 years of AIRS products have been used by the climate research and application communities. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), in collaboration with NASA Sounder Team at JPL, provides processing, archiving, and distribution services for NASA sounders: the present Aqua AIRS mission and the succeeding Suomi National Polar-Orbiting Partnership (SNPP) Cross-track Infrared Sounder (CrIS) mission. We generated a Multi-year Monthly Mean and Anomaly product using 14 years of AIRS standard monthly product. The product includes Air Temperature at the Surface and Surface Skin Temperature, both in Ascending/Daytime and Descending/Nighttime mode. The temperature variables and their anomalies are deployed to Giovanni, a Web-based application developed by the GES DISC. Giovanni provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. It is also a powerful tool that stakeholders can use for decision support in planning and preparing for increased climate variability. In this presentation, we demonstrate the functions in Giovanni with use cases employing AIRS Multi-year Monthly Mean and Anomaly variables.

  19. Cardiorespiratory physiological phenotypic plasticity in developing air-breathing anabantid fishes (Betta splendens and Trichopodus trichopterus).

    Science.gov (United States)

    Mendez-Sanchez, Jose F; Burggren, Warren W

    2017-08-01

    Developmental plasticity of cardiorespiratory physiology in response to chronic hypoxia is poorly understood in larval fishes, especially larval air-breathing fishes, which eventually in their development can at least partially "escape" hypoxia through air breathing. Whether the development air breathing makes these larval fishes less or more developmentally plastic than strictly water breathing larval fishes remains unknown. Consequently, developmental plasticity of cardiorespiratory physiology was determined in two air-breathing anabantid fishes ( Betta splendens and Trichopodus trichopterus ). Larvae of both species experienced an hypoxic exposure that mimicked their natural environmental conditions, namely chronic nocturnal hypoxia (12 h at 17 kPa or 14 kPa), with a daily return to diurnal normoxia. Chronic hypoxic exposures were made from hatching through 35 days postfertilization, and opercular and heart rates measured as development progressed. Opercular and heart rates in normoxia were not affected by chronic nocturnal hypoxic. However, routine oxygen consumption M˙O2 (~4  μ mol·O 2 /g per hour in normoxia in larval Betta ) was significantly elevated by chronic nocturnal hypoxia at 17 kPa but not by more severe (14 kPa) nocturnal hypoxia. Routine M˙O2 in Trichopodus (6-7  μ mol·O 2 /g per hour), significantly higher than in Betta , was unaffected by either level of chronic hypoxia. P Crit , the PO 2 at which M˙O2 decreases as ambient PO 2 falls, was measured at 35 dpf, and decreased with increasing chronic hypoxia in Betta , indicating a large, relatively plastic hypoxic tolerance. However, in contrast, P Crit in Trichopodus increased as rearing conditions grew more hypoxic, suggesting that hypoxic acclimation led to lowered hypoxic resistance. Species-specific differences in larval physiological developmental plasticity thus emerge between the relatively closely related Betta and Trichopodus Hypoxic rearing increased hypoxic tolerance in

  20. Environmental enrichment for a mixed-species nocturnal mammal exhibit.

    Science.gov (United States)

    Clark, Fay E; Melfi, Vicky A

    2012-01-01

    Environmental enrichment (EE) is an integral aspect of modern zoo animal management but, empirical evaluation of it is biased toward species housed in single-species groups. Nocturnal houses, where several nocturnal species are housed together, are particularly overlooked. This study investigated whether three species (nine-banded armadillos, Dasypus novemcinctus; Senegal bush babies, Galago senegalensis; two-toed sloths, Choloepus didactylus) in the nocturnal house at Paignton Zoo Environmental Park, UK could be enriched using food-based and sensory EE. Subjects were an adult male and female of each species. EE was deemed effective if it promoted target species-typical behaviors, behavioral diversity, and increased use of enriched exhibit zones. Results from generalized linear mixed models demonstrated that food-based EE elicited the most positive behavioral effects across species. One set of food-based EEs (Kong®, termite mound and hanging food) presented together was associated with a significant increase in species-typical behaviors, increased behavioral diversity, and increased use of enriched exhibit zones in armadillos and bush babies. Although one type of sensory EE (scented pine cones) increased overall exhibit use in all species, the other (rainforest sounds) was linked to a significant decrease in species-typical behavior in bush babies and sloths. There were no intra or interspecies conflicts over EE, and commensalism occurred between armadillos and bush babies. Our data demonstrate that simple food-based and sensory EE can promote positive behavioral changes in a mixed-species nocturnal mammal exhibit. We suggest that both food and sensory EE presented concurrently will maximize opportunities for naturalistic activity in all species. © 2011 Wiley Periodicals, Inc.

  1. Lack of nocturnal blood pressure fall in elderly bedridden hypertensive patients with cerebrovascular disease.

    Science.gov (United States)

    Sasaki, Masato; Ando, Hitoshi; Fujimura, Akio

    2012-02-01

    To prevent recurrence of cerebrovascular disease (CVD), adequate control of blood pressure (BP) is extremely important for the treatment of hypertensive CVD patients. As absence of the nocturnal fall of BP by the expected 10-20% from daytime levels is reported to exaggerate target organ injury, 24-h ambulatory blood pressure monitoring (ABPM) was conducted, especially to obtain data during nighttime sleep. Forty-eight elderly bedridden chronic phase CVD hypertensive patients (assessed 1-3 mo after CVD accident) participated. As a group, nocturnal BP was higher than diurnal BP, whereas nocturnal pulse rate was lower than diurnal pulse rate. The nocturnal BP fall was blunted in most (∼90%) of the patients. These results suggest that to perform a rational drug treatment, it is essential to do 24-h ABPM before initiation of antihypertensive therapy in elderly bedridden hypertensive CVD patients.

  2. High-temperature hydrogen-air-steam detonation experiments in the BNL small-scale development apparatus

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsberg, T.; Boccio, J.; Economos, C.; Finfrock, C.; Gerlach, L.; Sato, K.

    1994-01-01

    The Small-Scale Development Apparatus (SSDA) was constructed to provide a preliminary set of experimental data to characterize the effect of temperature on the ability of hydrogen-air-steam-mixtures to undergo detonations and, equally important, to support design of the larger-scale High-Temperature Combustion Facility (HTCF) by providing a test bed for solution of a number of high-temperature design and operational problems. The SSDA, the central element of which is 10-cm inside diameter, 6.1-m long tubular test vessel designed to permit detonation experiments at temperatures up to 700K, was employed to study self-sustained detonations in gaseous mixtures of hydrogen, air, and steam at temperature between 300K and 650K at a fixed pressure of 0.1 MPa. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air gas mixture temperature, in the range 300K to 650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments. Experiments were conducted to measure the rate of hydrogen oxidation in the absence of ignition sources at temperatures of 500K and 650K, for hydrogen-air mixtures of 15% and 50%, and for a mixture of equimolar hydrogen-air and 30% steam at 650K. The rate of hydrogen oxidation was found to be significant at 650K. Reduction of hydrogen concentration by chemical reaction from 50 to 44% hydrogen, and from 15 to 11% hydrogen, were observed on a time frame of minutes. The DeSoete rate equation predicts the 50% experiment very well, but greatly underestimates the reaction rate of the lean mixtures

  3. Kinetic mechanism of molecular energy transfer and chemical reactions in low-temperature air-fuel plasmas.

    Science.gov (United States)

    Adamovich, Igor V; Li, Ting; Lempert, Walter R

    2015-08-13

    This work describes the kinetic mechanism of coupled molecular energy transfer and chemical reactions in low-temperature air, H2-air and hydrocarbon-air plasmas sustained by nanosecond pulse discharges (single-pulse or repetitive pulse burst). The model incorporates electron impact processes, state-specific N(2) vibrational energy transfer, reactions of excited electronic species of N(2), O(2), N and O, and 'conventional' chemical reactions (Konnov mechanism). Effects of diffusion and conduction heat transfer, energy coupled to the cathode layer and gasdynamic compression/expansion are incorporated as quasi-zero-dimensional corrections. The model is exercised using a combination of freeware (Bolsig+) and commercial software (ChemKin-Pro). The model predictions are validated using time-resolved measurements of temperature and N(2) vibrational level populations in nanosecond pulse discharges in air in plane-to-plane and sphere-to-sphere geometry; temperature and OH number density after nanosecond pulse burst discharges in lean H(2)-air, CH(4)-air and C(2)H(4)-air mixtures; and temperature after the nanosecond pulse discharge burst during plasma-assisted ignition of lean H2-mixtures, showing good agreement with the data. The model predictions for OH number density in lean C(3)H(8)-air mixtures differ from the experimental results, over-predicting its absolute value and failing to predict transient OH rise and decay after the discharge burst. The agreement with the data for C(3)H(8)-air is improved considerably if a different conventional hydrocarbon chemistry reaction set (LLNL methane-n-butane flame mechanism) is used. The results of mechanism validation demonstrate its applicability for analysis of plasma chemical oxidation and ignition of low-temperature H(2)-air, CH(4)-air and C(2)H(4)-air mixtures using nanosecond pulse discharges. Kinetic modelling of low-temperature plasma excited propane-air mixtures demonstrates the need for development of a more accurate

  4. Understanding nocturnal enuresis and its treatments.

    Science.gov (United States)

    Potter, D C; Wogoman, H A; Nietch, P

    1999-09-01

    Nocturnal enuresis is a condition that touches the lives of many children around the world. Affected children and their parents may experience feelings of guilt, frustration, and anxiety because of their lack of control over the situation. Nurses can play an important role in providing education to families in regards to the causes and treatment of enuresis. It is important for nurses to understand the problem of bedwetting thoroughly so they can assist the family in making an informed decision about the various options currently available. Nocturnal enuresis (bedwetting) is a common disorder that frequently results in frustration and stress on not only the children that experience it, but their parents as well. Scharf, Pravda, Jennings, Kauffman, and Ringel (1987) note that an estimated five to seven million children in America experience enuresis. Enuresis has family and psychosocial aspects, along with financial concerns. Therefore, it is important for nurses to be aware of the causes of enuresis, how it affects the family, and the current treatments that are available.

  5. Nocturnal eating predicts tooth loss among adults: results from the Danish MONICA study

    DEFF Research Database (Denmark)

    Lundgren, Jennifer D; Williams, Karen B; Heitmann, Berit L

    2010-01-01

    The relationship between nocturnal eating, such as that associated with night eating syndrome (NES), and oral health is unknown. This study sought to determine if nocturnal eating is related to tooth loss in a large, epidemiologic sample. Danes (N=2217; age range 30-60 years, M BMI [kg/m(2...

  6. Evaluation of the occurrence and diagnose definitions for Nocturnal Polyuria in Spinal Cord Injured patients during rehabilitation.

    Science.gov (United States)

    Viaene, Annick; Denys, Marie-Astrid; Goessaert, An-Sofie; Claeys, Jana; Raes, Ann; Roggeman, Saskia; Everaert, Karel

    2017-11-03

    Little is known about the occurrence of nocturnal polyuria in spinal cord injured (SCI) patients and the definitions which are preferable in this population. To determine the occurrence of nocturnal polyuria (NP) in spinal cord injured patients during in-patient rehabilitation in the Ghent University Hospital. To study the influence of different time periods (daytime, bed rest and sleep) on the accuracy of the existing diagnose definitions for NP specifically for this type of patients. Retrospective study using patient records. SCI patients during hospital based rehabilitation between 2011 and 2014. Seventy-four SCI patients were selected and their records of frequency-volume charts were examined, after exclusion of unreliable data, forty-seven patients were retained for the current study. Retrospective study using data from frequency-volume charts of either two or three days from patients with SCI. Nocturnal urine production (NUP) and nocturnal polyuria index (NPi) were calculated. There was a significant increase in diuresis, calculated as urine production, between day time and bed rest (p=0.008) and between day time and sleep (p=0.001). All patients showed nocturnal polyuria during a 12-hour night time period (including both bed rest and sleep) and 39 patients showed nocturnal polyuria during the 8 hour period of sleep. There was no significant difference in mean urine production between bed rest and sleep. Prevalence of NP did not significantly differ between the complete or incomplete SCI patients or between patients with higher and lower SCI levels. This study showed that the occurrence of nocturnal polyuria in patients with SCI is high and that it is important to consider which definitions of NP are used for diagnosis. Increase in diuresis is observed during bed rest and sleep and the diagnose is correctly estimated when nocturnal urine production definitions are used in both time periods. In accordance with what was expected, diagnose of NP was

  7. Crowdsourcing urban air temperatures through smartphone battery temperatures in São Paulo, Brazil

    NARCIS (Netherlands)

    Droste, A.M.; Pape, J.J.; Overeem, A.; Leijnse, H.; Steeneveld, G.J.; Delden, van A.J.; Uijlenhoet, R.

    2017-01-01

    Crowdsourcing as a method to obtain and apply vast datasets is rapidly becoming prominent in meteorology, especially for urban areas where routine weather observations are scarce. Previous studies showed that smartphone battery temperature readings can be used to estimate the daily and citywide air

  8. Changes in duration of dry and wet spells associated with air temperatures in Russia

    Science.gov (United States)

    Ye, Hengchun

    2018-03-01

    This study uses daily precipitation records from 517 Russian stations (1966-2010) to examine the relationships between continuous dry and wet day duration and surface air temperature for all four seasons. The study found that both mean and extreme durations of dry periods increase with air temperature at about 7.0% (0.24 day/°C) and 7.7% (0.86 day/°C) respectively, while those of wet periods decrease at about 1.3% (-0.02 day/°C) and 2.2% (-0.10 day/°C) respectively averaged over the entire study region during summer. An increase in the duration of dry periods with higher air temperature is also found in other seasons at locations with a mean seasonal air temperature of about -5 °C or higher. Opposite relationships of shorter durations of dry periods and longer wet periods associated with higher air temperature are observed over the northern part of the study region in winter. The changes in durations of both dry and wet periods have significant correlations with the changes in total dry and wet days but are about 2.5 times higher for dry periods and 0.5 times lower for wet periods. The study also found that locations with longer durations of dry periods experience faster rates of increase in air temperature, suggesting the likelihood of exacerbating drought severity in drier and/or warmer locations for all seasons.

  9. Nocturnal Polyuria and Hypertension in Patients with Lifestyle Related Diseases and Overactive Bladder.

    Science.gov (United States)

    Yokoyama, Osamu; Nishizawa, Osamu; Homma, Yukio; Takeda, Masayuki; Gotoh, Momokazu; Kakizaki, Hidehiro; Akino, Hironobu; Hayashi, Koichi; Yonemoto, Koji

    2017-02-01

    The objective of this multicenter cross-sectional study was to investigate the relationship of nocturnal polyuria in patients with common lifestyle related diseases and overactive bladder, with special attention to hypertension. After baseline assessment, patients recorded 24-hour urinary frequency/volume, blood pressure and heart rate for 3 days. They were stratified into 4 groups based on mean blood pressure, including no hypertension, and controllable, untreated and uncontrolled hypertension, respectively. The 2,353 eligible patients, who had urinary urgency once or more per week and 1 or more nocturnal toilet visits, were enrolled from 543 sites in Japan. Of these patients complete data, including the 24-hour frequency volume chart, were collected from 1,271. Multivariable analyses showed a statistically significant association of nocturnal polyuria with increasing age (OR 1.04, 95% CI 1.02-1.05, p polyuria in women alone (p = 0.01 and 0.03, respectively). Lower urinary tract symptoms suggestive of benign prostatic hyperplasia were significantly associated with nocturnal polyuria in men alone (p polyuria was significantly associated with age, male gender, and untreated hypertension in patients with lifestyle related diseases and overactive bladder. The association between hypertension and nocturnal polyuria was significant in women alone. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Interactive short-term effects of equivalent temperature and air pollution on human mortality in Berlin and Lisbon.

    Science.gov (United States)

    Burkart, Katrin; Canário, Paulo; Breitner, Susanne; Schneider, Alexandra; Scherber, Katharina; Andrade, Henrique; Alcoforado, Maria João; Endlicher, Wilfried

    2013-12-01

    There is substantial evidence that both temperature and air pollution are predictors of mortality. Thus far, few studies have focused on the potential interactive effects between the thermal environment and different measures of air pollution. Such interactions, however, are biologically plausible, as (extreme) temperature or increased air pollution might make individuals more susceptible to the effects of each respective predictor. This study investigated the interactive effects between equivalent temperature and air pollution (ozone and particulate matter) in Berlin (Germany) and Lisbon (Portugal) using different types of Poisson regression models. The findings suggest that interactive effects exist between air pollutants and equivalent temperature. Bivariate response surface models and generalised additive models (GAMs) including interaction terms showed an increased risk of mortality during periods of elevated equivalent temperatures and air pollution. Cold effects were mostly unaffected by air pollution. The study underscores the importance of air pollution control in mitigating heat effects. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Getting a good night sleep? The importance of recognizing and treating nocturnal hypokinesia in Parkinson's disease.

    Science.gov (United States)

    Bhidayasiri, Roongroj; Trenkwalder, Claudia

    2018-01-05

    When Parkinson's disease (PD) patients are asked about the quality of their sleep, their answers are dominated by difficulties associated with impaired mobility in bed, medically referred to as nocturnal hypokinesia. Nocturnal hypokinesia is symptomatic from the mid-stage of the disease, affecting up to 70% of PD patients, and contributes to poor sleep quality, and increased carer burden. Here we explore four areas of nocturnal hypokinesia that are relevant to clinical practice, namely: manifestations and definition; clinical assessment and objective monitoring; etiologies and contributing factors; and evidence-based therapeutic approaches. In addition, we provide an operational definition of what constitutes nocturnal hypokinesia and outline different methods of assessment, ranging from clinical interviews and rating scales to objective night-time monitoring with inertial sensors. Optimal management of nocturnal hypokinesia in PD begins with recognizing its manifestation by inquiring about cardinal symptoms and contributing factors from, not only patients, but also carers, followed by formal assessment, and the application of individualized evidence-based treatment. Night-time dopaminergic treatment is the primary therapy; however, careful clinical judgment is required to balance the benefits with the potential adverse events related to nocturnal dopaminergic stimulation. Future studies are needed to explore the practicality of home-based objective assessment of nocturnal hypokinesia, new therapeutic options not limited to dopaminergic medications, and non-pharmacologic approaches, including training on compensatory strategies and bedroom adaptations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. NOS CO-OPS Meteorological Data, Air Temperature, 6-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has Air Temperature data from NOAA NOS Center for Operational Oceanographic Products and Services (CO-OPS). WARNING: These preliminary data have not...

  13. Paroxysmal nocturnal hemoglobinuria and telomere length predicts response to immunosuppressive therapy in pediatric aplastic anemia.

    Science.gov (United States)

    Narita, Atsushi; Muramatsu, Hideki; Sekiya, Yuko; Okuno, Yusuke; Sakaguchi, Hirotoshi; Nishio, Nobuhiro; Yoshida, Nao; Wang, Xinan; Xu, Yinyan; Kawashima, Nozomu; Doisaki, Sayoko; Hama, Asahito; Takahashi, Yoshiyuki; Kudo, Kazuko; Moritake, Hiroshi; Kobayashi, Masao; Kobayashi, Ryoji; Ito, Etsuro; Yabe, Hiromasa; Ohga, Shouichi; Ohara, Akira; Kojima, Seiji

    2015-12-01

    Acquired aplastic anemia is an immune-mediated disease characterized by severe defects in stem cell number resulting in hypocellular marrow and peripheral blood cytopenias. Minor paroxysmal nocturnal hemoglobinuria populations and a short telomere length were identified as predictive biomarkers of immunosuppressive therapy responsiveness in aplastic anemia. We enrolled 113 aplastic anemia patients (63 boys and 50 girls) in this study to evaluate their response to immunosuppressive therapy. The paroxysmal nocturnal hemoglobinuria populations and telomere length were detected by flow cytometry. Forty-seven patients (42%) carried a minor paroxysmal nocturnal hemoglobinuria population. The median telomere length of aplastic anemia patients was -0.99 standard deviation (SD) (range -4.01-+3.01 SD). Overall, 60 patients (53%) responded to immunosuppressive therapy after six months. Multivariate logistic regression analysis identified the absence of a paroxysmal nocturnal hemoglobinuria population and a shorter telomere length as independent unfavorable predictors of immunosuppressive therapy response at six months. The cohort was stratified into a group of poor prognosis (paroxysmal nocturnal hemoglobinuria negative and shorter telomere length; 37 patients) and good prognosis (paroxysmal nocturnal hemoglobinuria positive and/or longer telomere length; 76 patients), respectively. The response rates of the poor prognosis and good prognosis groups at six months were 19% and 70%, respectively (P<0.001). The combined absence of a minor paroxysmal nocturnal hemoglobinuria population and a short telomere length is an efficient predictor of poor immunosuppressive therapy response, which should be considered while deciding treatment options: immunosuppressive therapy or first-line hematopoietic stem cell transplantation. The trial was registered in www.umin.ac.jp with number UMIN000017972. Copyright© Ferrata Storti Foundation.

  14. Numerical Simulation of Air Temperature and Velocity in a Naturally Ventilated Office

    Directory of Open Access Journals (Sweden)

    S. Shodiya

    2017-04-01

    Full Text Available This paper presents a numerical simulation of air velocity and air temperature distribution in an office room of Computer Engineering Department of University of Maiduguri which is naturally ventilated. The office room under investigation with the dimension 5 m × 5 m × 4 m has a door in the East direction, and two windows, one in the East direction and the other in the South direction. For cost effectiveness, numerical solutions of steady-state airflow and heat transfer were done using a complete two-dimensional model. The results showed that the windows and the door could not undertake indoor heat load that can make the occupants to be thermally comfortable. In activity area where people sit and stand, the air velocity is moderate, this is about 0.98 m/s on the average. In addition, the temperature in this area is relatively high of about 302 K (29 °C on the average. Based on the American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE standard for comfort environment in summer (air temperature: 293 – 299 K (20 – 26 °C; air velocity: 0.5 – 0.8 m/s, the natural ventilation for the office room cannot give a thermal comfort for the inhabitant of the room. However, a window, if installed opposite the door could improve the ventilation of the office.

  15. Retinal and optical adaptations for nocturnal vision in the halictid bee Megalopta genalis.

    Science.gov (United States)

    Greiner, Birgit; Ribi, Willi A; Warrant, Eric J

    2004-06-01

    The apposition compound eye of a nocturnal bee, the halictid Megalopta genalis, is described for the first time. Compared to the compound eye of the worker honeybee Apis mellifera and the diurnal halictid bee Lasioglossum leucozonium, the eye of M. genalis shows specific retinal and optical adaptations for vision in dim light. The major anatomical adaptations within the eye of the nocturnal bee are (1) nearly twofold larger ommatidial facets and (2) a 4-5 times wider rhabdom diameter than found in the diurnal bees studied. Optically, the apposition eye of M. genalis is 27 times more sensitive to light than the eyes of the diurnal bees. This increased optical sensitivity represents a clear optical adaptation to low light intensities. Although this unique nocturnal apposition eye has a greatly improved ability to catch light, a 27-fold increase in sensitivity alone cannot account for nocturnal vision at light intensities that are 8 log units dimmer than during daytime. New evidence suggests that additional neuronal spatial summation within the first optic ganglion, the lamina, is involved.

  16. Discrepancies between modeled and observed nocturnal isoprene in an urban environment and the possible causes: A case study in Houston

    Science.gov (United States)

    Diao, Lijun; Choi, Yunsoo; Czader, Beata; Li, Xiangshang; Pan, Shuai; Roy, Anirban; Souri, Amir Hossein; Estes, Mark; Jeon, Wonbae

    2016-11-01

    Air quality simulations were conducted using the Community Multiscale Air Quality (CMAQ) model for nocturnal isoprene in September 2013 using the United States Environmental Protection Agency's (EPA's) National Emissions Inventory of 2011 (NEI, 2011). The results were evaluated against measurements collected at eight Texas Commission on Environmental Quality (TCEQ) Automated Gas Chromatographs (AutoGCs) monitoring stations. The comparisons demonstrated two distinctive behaviors: overestimation before midnight (20:00-23:00 p.m. local time) versus underestimation after midnight (00:00-06:00 a.m.). Analyses identify the uncertainties in nitrate radical (NO3) concentration and vertical mixing as the possible minor factors contributing to the underestimation, and the underestimated wind speed as the major factor contributing to the overestimation. Further analysis links isoprene underestimation to the uncertainties in the nocturnal isoprene anthropogenic emissions in the NEI (2011) over industrial areas in Houston. This can be substantiated by the fact that the observed nighttime isoprene concentrations increased when the wind direction veered back from southeast to northeast, placing the stations downwind of industrial facilities. A sensitivity run with adjusted anthropogenic isoprene emissions in the later part of the night (i.e., the emissions were multiplied by the hourly underestimation factors ranging from 3.81 to 14.82) yielded closer isoprene predictions after midnight with slightly improved model mean (0.15 to 0.20 ppb), mean error (- 0.10 to - 0.04 ppb), mean absolute error (0.18 to 0.15 ppb), root mean squared error (RMSE, 0.27 to 0.25 ppb), and index of agreement (IOA, 0.66 to 0.68). The insignificant improvement was likely due to the uncertainties in the location of the high-peaked anthropogenic emissions. The impacts of the nighttime-adjusted isoprene emissions on the isoprene oxidation products, organic nitrate and ozone, were found to be minimal. This

  17. Air temperature sensors: dependence of radiative errors on sensor diameter in precision metrology and meteorology

    Science.gov (United States)

    de Podesta, Michael; Bell, Stephanie; Underwood, Robin

    2018-04-01

    In both meteorological and metrological applications, it is well known that air temperature sensors are susceptible to radiative errors. However, it is not widely known that the radiative error measured by an air temperature sensor in flowing air depends upon the sensor diameter, with smaller sensors reporting values closer to true air temperature. This is not a transient effect related to sensor heat capacity, but a fluid-dynamical effect arising from heat and mass flow in cylindrical geometries. This result has been known historically and is in meteorology text books. However, its significance does not appear to be widely appreciated and, as a consequence, air temperature can be—and probably is being—widely mis-estimated. In this paper, we first review prior descriptions of the ‘sensor size’ effect from the metrological and meteorological literature. We develop a heat transfer model to describe the process for cylindrical sensors, and evaluate the predicted temperature error for a range of sensor sizes and air speeds. We compare these predictions with published predictions and measurements. We report measurements demonstrating this effect in two laboratories at NPL in which the air flow and temperature are exceptionally closely controlled. The results are consistent with the heat-transfer model, and show that the air temperature error is proportional to the square root of the sensor diameter and that, even under good laboratory conditions, it can exceed 0.1 °C for a 6 mm diameter sensor. We then consider the implications of this result. In metrological applications, errors of the order of 0.1 °C are significant, representing limiting uncertainties in dimensional and mass measurements. In meteorological applications, radiative errors can easily be much larger. But in both cases, an understanding of the diameter dependence allows assessment and correction of the radiative error using a multi-sensor technique.

  18. Laminar Flame Velocity and Temperature Exponent of Diluted DME-Air Mixture

    Science.gov (United States)

    Naseer Mohammed, Abdul; Anwar, Muzammil; Juhany, Khalid A.; Mohammad, Akram

    2017-03-01

    In this paper, the laminar flame velocity and temperature exponent diluted dimethyl ether (DME) air mixtures are reported. Laminar premixed mixture of DME-air with volumetric dilutions of carbon dioxides (CO2) and nitrogen (N2) are considered. Experiments were conducted using a preheated mesoscale high aspect-ratio diverging channel with inlet dimensions of 25 mm × 2 mm. In this method, flame velocities are extracted from planar flames that were stabilized near adiabatic conditions inside the channel. The flame velocities are then plotted against the ratio of mixture temperature and the initial reference temperature. A non-linear power law regression is observed suitable. This regression analysis gives the laminar flame velocity at the initial reference temperature and temperature exponent. Decrease in the laminar flame velocity and increase in temperature exponent is observed for CO2 and N2 diluted mixtures. The addition of CO2 has profound influence when compared to N2 addition on both flame velocity and temperature exponent. Numerical prediction of the similar mixture using a detailed reaction mechanism is obtained. The computational mechanism predicts higher magnitudes for laminar flame velocity and smaller magnitudes of temperature exponent compared to experimental data.

  19. Notas sobre la ecología de Phyllodactylus reissi (Phyllodactylidae: Sauria) en el Parque Nacional Cerros de Amotape (Tumbes, Perú)

    OpenAIRE

    Jordán Arizmendi, Juan Carlos

    2012-01-01

    Some basics aspects on the ecology of the nocturnal gecko Phyllodactylus reissi from Parque Nacional Cerros de Amotape (Tumbes, Peru) are described. This species used rock boulders (57,4%) and trees (31,9%) as microhabitats primarily, exhibiting a nocturnal activity pattern, with a peak between 2100-2200 hours, remaining active until midnight. Body temperature (mean 24,4 ºC) was correlated with both air and substrate temperature, with the last variable affecting in higher degree (47%) the bod...

  20. A three-dimensional mathematical model to predict air-cooling flow and temperature distribution of wire loops in the Stelmor air-cooling system

    International Nuclear Information System (INIS)

    Hong, Lingxiang; Wang, Bo; Feng, Shuai; Yang, Zhiliang; Yu, Yaowei; Peng, Wangjun; Zhang, Jieyu

    2017-01-01

    Highlights: • A 3-dimentioanl mathematical models for complex wire loops was set up in Stelmor. • The air flow field in the cooling process was simulated. • The convective heat transfer coefficient was simulated coupled with air flow field. • The temperature distribution with distances was predicted. - Abstract: Controlling the forced air cooling conditions in the Stelmor conveyor line is important for improving the microstructure and mechanical properties of steel wire rods. A three-dimensional mathematical model incorporating the turbulent flow of the cooling air and heat transfer of the wire rods was developed to predict the cooling process in the Stelmor air-cooling line of wire rolling mills. The distribution of cooling air from the plenum chamber and the forced convective heat transfer coefficient for the wire loops were simulated at the different locations over the conveyor. The temperature profiles and cooling curves of the wire loops in Stelmor conveyor lines were also calculated by considering the convective heat transfer, radiative heat transfer as well as the latent heat during transformation. The calculated temperature results using this model agreed well with the available measured results in the industrial tests. Thus, it was demonstrated that this model can be useful for studying the air-cooling process and predicting the temperature profile and microstructure evolution of the wire rods.

  1. Impact of aspect ratio and solar heating on street canyon air temperature

    International Nuclear Information System (INIS)

    Memon, R.A.; Lal, K.

    2011-01-01

    The results obtained from RNG (Re-Normalization Group) version of k-and turbulence model are reported in this study. The model is adopted to elucidate the impact of different building aspect ratios (i.e., ratio of building-height-to-street-canyon-width) and solar heating on temperatures in street canyon. The validation of Navier-Stokes and energy an sport equations showed that the model prediction for air-temperature and ambient wind provides reasonable accuracy. The model was applied on AR (Aspect Ratios) one to eight and surface temperature difference (delta and theta/sub s-a/)) of 2 -8. Notably, air-temperatures were higher in high AR street canyons in particular on the leeward side of the street canyon. Further investigation showed that the difference between the air-temperature 'high and low AR street canyons (AR) was positive and high with higher delta and theta/sub s-a/) conversely, the AR become negative and low gradually with lower values of delta and theta(/sub s-a/). These results could be very beneficial for the city and regional planners, civil engineers Id HVAC experts who design street canyons and strive for human thermal comfort with minimum possible energy requirements. (author)

  2. Impact of Aspect Ratio and Solar Heating on Street Conyn Air Temperature

    Directory of Open Access Journals (Sweden)

    Rizwan Ahmed Memon

    2011-01-01

    Full Text Available The results obtained from RNG (Re-Normalization Group version of k-? turbulence model are reported in this study. The model is adopted to elucidate the impact of different building aspect ratios (i.e., ratio of building-height-to-street-canyon-width and solar heating on temperatures in street canyon. The validation of Navier-Stokes and energy transport equations showed that the model prediction for air-temperature and ambient wind provides reasonable accuracy. The model was applied on AR (Aspect Ratios one to eight and surface temperature difference (??s-a of 2 -8. Notably, air-temperatures were higher in high AR street canyons in particular on the leeward side of the street canyon. Further investigation showed that the difference between the air-temperature of high and low AR street canyons ( AR was positive and high with higher ??s-a. Conversely, the AR become negative and low gradually with lower values of ??s-a. These results could be very beneficial for the city and regional planners, civil engineers and HVAC experts who design street canyons and strive for human thermal comfort with minimum possible energy requirements.

  3. Air-Cooled Design of a Temperature-Swing Adsorption Compressor for Closed-Loop Air Revitalization Systems

    Science.gov (United States)

    Mulloth, Lila M.; Affleck, Dave L.; Rosen, Micha; LeVan, M. Douglas; Wang, Yuan; Cavalcante, Celio L.

    2004-01-01

    The air revitalization system of the International Space Station (ISS) operates in an open loop mode and relies on the resupply of oxygen and other consumables from earth for the life support of astronauts. A compressor is required for delivering the carbon dioxide from a removal assembly to a reduction unit to recover oxygen and thereby closing the air-loop. We have a developed a temperature-swing adsorption compressor (TSAC) for performing these tasks that is energy efficient, quiet, and has no rapidly moving parts. This paper discusses the mechanical design and the results of thermal model validation tests of a TSAC that uses air as the cooling medium.

  4. Nocturnal faecal soiling and anal masturbation.

    Science.gov (United States)

    Clark, A F; Tayler, P J; Bhate, S R

    1990-01-01

    Two cases of late onset faecal soiling as a result of anal masturbation in children who were neither mentally handicapped nor psychotic were studied. The role of soiling in aiding the young person and his family to avoid separating and maturing is highlighted. We suggest that the association of anal masturbation and resistant nocturnal soiling may be unrecognised. PMID:2270946

  5. Reproductive biology of Echinopsis terscheckii (Cactaceae): the role of nocturnal and diurnal pollinators.

    Science.gov (United States)

    Ortega-Baes, P; Saravia, M; Sühring, S; Godínez-Alvarez, H; Zamar, M

    2011-01-01

    The aim of this study was to analyse the reproductive biology of Echinopsis terscheckii, a species endemic to northwest Argentina that has nocturnal flowers. We expected that this species had a generalised pollination system, with moths and diurnal visitors as the primary pollinators. To test this, we studied the floral biology, breeding system and floral visitors of this species and the effectiveness of nocturnal and diurnal visitors. Floral biology was defined based on floral morphology, floral cycle and nectar production of the flowers. The breeding system and relative contributions of diurnal and nocturnal visitors to fruit and seed set were analysed through field experiments. E. terscheckii flowers opened at sunset and closed the following day. The peak of nectar production occurred at midnight. Flowers were determined to be self-incompatible. Moths, bees and birds were identified as floral visitors. Moths were the most frequent visitors at night, whereas bees were the most frequent visitors during the day. Fruit production by diurnal pollinators was less than that by nocturnal pollinators; among all floral visitors, moths were the most effective pollinators. We have demonstrated for the first time that moths are the primary pollinators of columnar cacti of the genus Echinopsis. Our results suggest that moths might be important pollinators of columnar cactus species with nocturnal flowers in the extra-tropical deserts of South America. © 2010 German Botanical Society and The Royal Botanical Society of the Netherlands.

  6. Theoretical and Experimental Investigations of Highly Uprated Diesel Engine with Temperature Regulator of Supercharging Air

    Directory of Open Access Journals (Sweden)

    G. A. Vershina

    2005-01-01

    Full Text Available Mathematical model of a highly uprated diesel engine with turbo-supercharging and intercooler of supercharging air is given in die paper. Theoretical study based on the model has made it possible to design and test an intercooler with a temperature regulator of supercharging air. Test results prove efficiency of temperature regulation of supercharging air in operation of an engine at low loads with excess air factor more than 3.2.

  7. Air-ground temperature coupling and subsurface propagation of annual temperature signals

    Czech Academy of Sciences Publication Activity Database

    Smerdon, J. E.; Pollack, H. N.; Čermák, Vladimír; Enz, J. W.; Krešl, Milan; Šafanda, Jan; Wehmiller, J. F.

    2004-01-01

    Roč. 109, D21 (2004), D21107/1-10 ISSN 0148-0227 R&D Projects: GA AV ČR KSK3046108; GA MŠk(CZ) 1P05ME778 Grant - others:NSF(US) ATM-0081864; NSF(US) EAR9315052; NASA (US) GWEC 0000 0132 Institutional research plan: CEZ:AV0Z3012916 Keywords : heat transport * air-ground temperature coupling * paleoclimate Subject RIV: DB - Geology ; Mineralogy Impact factor: 2.839, year: 2004

  8. An investigation of the impact of nocturnal enuresis on children's self-concept.

    Science.gov (United States)

    Collier, J; Butler, R J; Redsell, S A; Evans, J H C

    2002-01-01

    This study sought to evaluate the relationship between the self-esteem and the self-image of children with nocturnal enuresis and to examine these in relation to various aspects of clinical and demographic variables. Previous studies investigating the self-esteem of bedwetting children have had mixed findings. Some studies report that children with nocturnal enuresis have a lower self-esteem than their non-bedwetting peers, but other studies report that children with nocturnal enuresis perceive themselves similarly to non-bedwetting children. However, what have not been studied to date are the self-perceptions of bedwetting children treated in community clinics. A total of 114 bedwetting children treated in community clinics provided the sample. School nurses conducted a routine first-visit assessment, collected baseline demographic and social information and invited children to complete the Butler Self-Image Profile and the Coopersmith Self-Esteem Inventory. Age and extent of wetting were not significantly related to self-concept measures. Girls had significantly (p = 0.008) higher scores on positive self-image compared with boys. Children with secondary enuresis also scored higher on positive self-image compared with those with primary nocturnal enuresis (p = 0.02). The Butler self-image scores indicated a number of significant links between positive self-image and enuresis variables, whereas the Coopersmith self-esteem scores generally failed to distinguish between the enuresis variables and closely reflected those of the negative self-image scores. These findings suggest that amongst children with nocturnal enuresis, the most vulnerable in terms of self-image are male, those with primary enuresis and those with a greater number of wet nights a week.

  9. Light Ray Displacements due to Air Temperature Gradient

    CERN Document Server

    Teymurazyan, A; CERN. Geneva

    2000-01-01

    Abstract In the optical monitoring systems suggested to control the geometry of tracking spectrometers, light beams serve as reference frames for the measurement of the tracking chamber displacements and deformations. It is shown that air temperature gradients can induce systematic errors which considerably exceed the intrinsic resolution of the monitoring system.

  10. Effects of Outside Air Temperature on Movement of Phosphine Gas in Concrete Elevator Bins

    Science.gov (United States)

    Studies that measured the movement and concentration of phosphine gas in upright concrete bins over time indicated that fumigant movement was dictated by air currents, which in turn, were a function of the difference between the average grain temperature and the average outside air temperature durin...

  11. High-intensity endurance training increases nocturnal heart rate variability in sedentary participants

    Directory of Open Access Journals (Sweden)

    A Nummela

    2016-01-01

    Full Text Available The effects of endurance training on endurance performance characteristics and cardiac autonomic modulation during night sleep were investigated during two 4-week training periods. After the first 4-week training period (3 x 40 min per week, at 75% of HRR the subjects were divided into HIGH group (n = 7, who performed three high-intensity endurance training sessions per week; and CONTROL group (n = 8 who did not change their training. An incremental treadmill test was performed before and after the two 4-weektraining periods. Furthermore, nocturnal RR-intervals were recorded after each training day. In the second 4-weektraining period HIGH group increased their V0Zmax (P = 0.005 more than CONTROL group. At the same time, nocturnal HR decreased (P = 0.039 and high-frequency power (HFP increased (P = 0.003 in HIGH group while no changes were observed in CONTROL group. Furthermore, a correlation was observed between the changes in nocturnal HFP and changes in V0Zmax during the second 4-week training period (r = 0.90, P < 0.001. The present study showed that the increased HFP is related to improved VO2max in sedentary subjects suggesting that nocturnal HFP can provide a useful method in monitoring individual responses to endurance training.

  12. Spatio-temporal behavior of brightness temperature in Tel-Aviv and its application to air temperature monitoring

    International Nuclear Information System (INIS)

    Pelta, Ran; Chudnovsky, A. Alexandra; Schwartz, Joel

    2016-01-01

    This study applies remote sensing technology to assess and examine the spatial and temporal Brightness Temperature (BT) profile in the city of Tel-Aviv, Israel over the last 30 years using Landsat imagery. The location of warmest and coldest zones are constant over the studied period. Distinct diurnal and temporal BT behavior divide the city into four different segments. As an example of future application, we applied mixed regression models with daily random slopes to correlate Landsat BT data with monitored air temperature (Tair) measurements using 14 images for 1989–2014. Our preliminary results show a good model performance with R"2 = 0.81. Furthermore, based on the model's results, we analyzed the spatial profile of Tair within the study domain for representative days. - Highlights: • The location of warmest and coldest zones are constant over the last 30 years. • Distinct diurnal and temporal Brightness Temperature behavior divide the city into four segments. • We assess air temperature from satellite surface temperature (R"2 = 0.81). - The location of warmest and coldest zones are constant over the last 30 years. Distinct diurnal and temporal Surface Temperature behavior divide the city into four different segments.

  13. Computation and measurement of air temperature distribution of an industrial melt blowing die

    Directory of Open Access Journals (Sweden)

    Wu Li-Li

    2014-01-01

    Full Text Available The air flow field of the dual slot die on an HDF-6D melt blowing non-woven equipment is computed numerically. A temperature measurement system is built to measure air temperatures. The computation results tally with the measured results proving the correctness of the computation. The results have great valuable significance in the actual melt blowing production.

  14. System and method for air temperature control in an oxygen transport membrane based reactor

    Science.gov (United States)

    Kelly, Sean M

    2016-09-27

    A system and method for air temperature control in an oxygen transport membrane based reactor is provided. The system and method involves introducing a specific quantity of cooling air or trim air in between stages in a multistage oxygen transport membrane based reactor or furnace to maintain generally consistent surface temperatures of the oxygen transport membrane elements and associated reactors. The associated reactors may include reforming reactors, boilers or process gas heaters.

  15. The complement inhibitor eculizumab in paroxysmal nocturnal hemoglobinuria.

    NARCIS (Netherlands)

    Hillmen, P.; Young, N.S.; Schubert, J.; Brodsky, R.A.; Socie, G.; Muus, P.; Roth, A.; Szer, J.; Elebute, M.O.; Nakamura, R.; Browne, P.; Risitano, A.M.; Hill, A.; Schrezenmeier, H.; Fu, C.L.; Maciejewski, J; Rollins, S.A.; Mojcik, C.F.; Rother, R.P.; Luzzatto, L.

    2006-01-01

    BACKGROUND: We tested the safety and efficacy of eculizumab, a humanized monoclonal antibody against terminal complement protein C5 that inhibits terminal complement activation, in patients with paroxysmal nocturnal hemoglobinuria (PNH). METHODS: We conducted a double-blind, randomized,

  16. Association between nocturnal bruxism and gastroesophageal reflux.

    Science.gov (United States)

    Miyawaki, Shouichi; Tanimoto, Yuko; Araki, Yoshiko; Katayama, Akira; Fujii, Akihito; Takano-Yamamoto, Teruko

    2003-11-01

    To examine the relationship between nocturnal bruxism and gastroesophageal reflux. Controlled descriptive study and double-blind, placebo-controlled, clinical study. Portable pH monitoring, electromyography, and audio-video recordings were conducted during the night in the subjects' home. Ten patients with bruxism and 10 normal subjects were matched for height, weight, age, and sex. They did not have symptoms of gastroesophageal reflux disease. Medication with a proton pump inhibitor (ie, a gastric-acid-inhibiting drug). The bruxism group showed a significantly higher frequency of nocturnal rhythmic masticatory muscle activity (RMMA) episodes (mean +/- SD: 6.7 +/- 2.2 times per hour) and a higher frequency and percentage of time of gastroesophageal reflux episodes with a pH less than 4.0 and 5.0 (0.5 +/- 0.9 and 3.6 +/- 1.6 times per hour and 1.3% +/- 2.5% and 7.4% +/- 12.6%, respectively) than the control group (RMMA episodes: 2.4 +/- 0.9 times per hour; gastroesophageal reflux episodes: 0.0 +/- 0.0 and 0.1 +/- 0.3 times per hour and 0.0% +/- 0.0% and 0.0% +/- 0.0%, respectively). In the bruxism group, 100% of the gastroesophageal reflux episodes with a pH less than 3.0 and 4.0 included both an RMMA episode and an electromyographic burst, the duration of which was approximately 0.5 to 1.0 seconds, probably representing swallowing of saliva. The majority of gastroesophageal reflux episodes with a pH of 4.0 to 5.0 also included both an RMMA episode and an electromyographic burst in the control and bruxism groups (100% +/- 0.0% vs 70.7% +/- 16.5%), again probably due to swallowing of saliva. The remaining minority of gastroesophageal reflux episodes with a pH of 4.0 to 5.0 contained only an electromyographic burst (swallowing of saliva). The frequency of RMMA episodes after the release of the medication from the proton pump inhibitor, which increased the gastric and esophageal pH, was significantly lower than that after administration of the placebo in the control

  17. Chronic air pollution and social deprivation as modifiers of the association between high temperature and daily mortality.

    Science.gov (United States)

    Benmarhnia, Tarik; Oulhote, Youssef; Petit, Claire; Lapostolle, Annabelle; Chauvin, Pierre; Zmirou-Navier, Denis; Deguen, Séverine

    2014-06-18

    Heat and air pollution are both associated with increases in mortality. However, the interactive effect of temperature and air pollution on mortality remains unsettled. Similarly, the relationship between air pollution, air temperature, and social deprivation has never been explored. We used daily mortality data from 2004 to 2009, daily mean temperature variables and relative humidity, for Paris, France. Estimates of chronic exposure to air pollution and social deprivation at a small spatial scale were calculated and split into three strata. We developed a stratified Poisson regression models to assess daily temperature and mortality associations, and tested the heterogeneity of the regression coefficients of the different strata. Deaths due to ambient temperature were calculated from attributable fractions and mortality rates were estimated. We found that chronic air pollution exposure and social deprivation are effect modifiers of the association between daily temperature and mortality. We found a potential interactive effect between social deprivation and chronic exposure with regards to air pollution in the mortality-temperature relationship. Our results may have implications in considering chronically polluted areas as vulnerable in heat action plans and in the long-term measures to reduce the burden of heat stress especially in the context of climate change.

  18. Excessive daytime sleepiness, nocturnal sleep duration and ...

    African Journals Online (AJOL)

    Background and objectives. Short nocturnal sleep duration resulting in sleep debt may be a cause of excessive daytime sleepiness (EDS). Severity of depression (psychopathology) has been found to be directly related to EDS. There is an association between sleep duration and mental health, so there may therefore be an ...

  19. Prevalence and risk factors of monosymptomatic nocturnal enuresis in Turkish children

    Directory of Open Access Journals (Sweden)

    Secil Ozkan

    2010-01-01

    Full Text Available Objectives : To determine the prevalence of primary monosymptomatic nocturnal enuresis (PMNE and assess risk factors that can cause this disease. Methods : After the determination of 15 primary schools in the provincial center of Ankara, questionnaires were given to 15,150 students to be answered by their parents. Detailed urologic history was obtained and physical examination applied to the students whose parents answered the questionnaire. After excluding children with polysymptomatic NE, 14060 questionnaires of MNE patients were evaluated. Demographic features with social and medical history of students and their parents, general approach of family to the children, school success of the students and general behavioral attitudes, method of toilet training and the presence of nocturnal enuresis were questioned. Results : MNE was determined in 9.0% (n: 1266 of the students and nocturnal enuresis frequency was higher in boys than girls (P< 0.05. Univariate analysis revealed gender, method of toilet training, sleep problems, school success, and general approach of the family to children and general behavioral attitudes of the children as significant factors. In logistic regression analysis; age, male gender, toilette training with threatening method, deep sleeper, sleep walking, being introverted and shy, significantly increases the risk of nocturnal enuresis. Conclusions : The current study suggests that the methods of toilet training are extremely important to prevent bedwetting and behavioral disorders due to enuresis. Parents should be well-informed about the appropriate toilet training method.

  20. Air temperature measurements based on the speed of sound to compensate long distance interferometric measurements

    Directory of Open Access Journals (Sweden)

    Astrua Milena

    2014-01-01

    Full Text Available A method to measure the real time temperature distribution along an interferometer path based on the propagation of acoustic waves is presented. It exploits the high sensitivity of the speed of sound in air to the air temperature. In particular, it takes advantage of a special set-up where the generation of the acoustic waves is synchronous with the amplitude modulation of a laser source. A photodetector converts the laser light to an electronic signal considered as reference, while the incoming acoustic waves are focused on a microphone and generate a second signal. In this condition, the phase difference between the two signals substantially depends on the temperature of the air volume interposed between the sources and the receivers. The comparison with the traditional temperature sensors highlighted the limit of the latter in case of fast temperature variations and the advantage of a measurement integrated along the optical path instead of a sampling measurement. The capability of the acoustic method to compensate the interferometric distance measurements due to air temperature variations has been demonstrated for distances up to 27 m.

  1. Forced-Air Warming Provides Better Control of Body Temperature in Porcine Surgical Patients

    Directory of Open Access Journals (Sweden)

    Brian T. Dent

    2016-09-01

    Full Text Available Background: Maintaining normothermia during porcine surgery is critical in ensuring subject welfare and recovery, reducing the risk of immune system compromise and surgical-site infection that can result from hypothermia. In humans, various methods of patient heating have been demonstrated to be useful, but less evaluation has been performed in techniques to prevent hypothermia perioperatively in pigs. Methods: We compared body temperature regulation during surgery before and after modification of the ambient temperature of the operating laboratories. Three different methods of heating were then compared; a standard circulating water mattress, a resistive fabric blanket, and a forced hot air system. The primary measure was percentage of temperature readings outside a specification range of 36.7–40.0 °C. Results: Tighter control of the ambient temperature while using a circulating water mattress reduced the occurrence of out-of-specification body temperature readings from 20.8% to 5.0%, with most of these the result of hypothermia. Use of a resistive fabric blanket further reduced out-of-specification readings to 1.5%, with a slight increase in the occurrence of hyperthermia. Use of a forced air system reduced out-of-specification readings to less 0.1%. Conclusions: Maintenance of normothermia perioperatively in pig can be improved by tightly controlling ambient temperatures. Use of a resistive blanket or a forced air system can lead to better control than a circulating water mattress, with the forced air system providing a faster response to temperature variations and less chance of hyperthermia.

  2. A Lithium-Air Battery Stably Working at High Temperature with High Rate Performance.

    Science.gov (United States)

    Pan, Jian; Li, Houpu; Sun, Hao; Zhang, Ye; Wang, Lie; Liao, Meng; Sun, Xuemei; Peng, Huisheng

    2018-02-01

    Driven by the increasing requirements for energy supply in both modern life and the automobile industry, the lithium-air battery serves as a promising candidate due to its high energy density. However, organic solvents in electrolytes are likely to rapidly vaporize and form flammable gases under increasing temperatures. In this case, serious safety problems may occur and cause great harm to people. Therefore, a kind of lithium-air that can work stably under high temperature is desirable. Herein, through the use of an ionic liquid and aligned carbon nanotubes, and a fiber shaped design, a new type of lithium-air battery that can effectively work at high temperatures up to 140 °C is developed. Ionic liquids can offer wide electrochemical windows and low vapor pressures, as well as provide high thermal stability for lithium-air batteries. The aligned carbon nanotubes have good electric and heat conductivity. Meanwhile, the fiber format can offer both flexibility and weavability, and realize rapid heat conduction and uniform heat distribution of the battery. In addition, the high temperature has also largely improved the specific powers by increasing the ionic conductivity and catalytic activity of the cathode. Consequently, the lithium-air battery can work stably at 140 °C with a high specific current of 10 A g -1 for 380 cycles, indicating high stability and good rate performance at high temperatures. This work may provide an effective paradigm for the development of high-performance energy storage devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Analysis of surface air temperature variations and local urbanization effects on central Yunnan Plateau, SW China

    Science.gov (United States)

    He, Yunling; Wu, Zhijie; Liu, Xuelian; Deng, Fuying

    2018-01-01

    With the surface air temperature (SAT) data at 37 stations on Central Yunnan Plateau (CYP) for 1961-2010 and the Defense Meteorological Satellite Program/Operational Linescan System (DMSP/OLS) nighttime light data, the temporal-spatial patterns of the SAT trends are detected using Sen's Nonparametric Estimator of Slope approach and MK test, and the impact of urbanization on surface warming is analyzed by comparing the differences between the air temperature change trends of urban stations and their corresponding rural stations. Results indicated that annual mean air temperature showed a significant warming trend, which is equivalent to a rate of 0.17 °C/decade during the past 50 years. Seasonal mean air temperature presents a rising trend, and the trend was more significant in winter (0.31 °C/decade) than in other seasons. Annual/seasonal mean air temperature tends to increase in most areas, and higher warming trend appeared in urban areas, notably in Kunming city. The regional mean air temperature series was significantly impacted by urban warming, and the urbanization-induced warming contributed to approximately 32.3-62.9 % of the total regional warming during the past 50 years. Meantime, the urbanization-induced warming trend in winter and spring was more significant than that in summer and autumn. Since 1985, the urban heat island (UHI) intensity has gradually increased. And the urban temperatures always rise faster than rural temperatures on the CYP.

  4. The effect of grass transpiration on the air temperature

    Czech Academy of Sciences Publication Activity Database

    Šír, M.; Tesař, Miroslav; Lichner, Ľ.; Czachor, H.

    2014-01-01

    Roč. 69, č. 11 (2014), s. 1570-1576 ISSN 0006-3088 Institutional support: RVO:67985874 Keywords : air temperature oscillations * embolism * plant transpiration * soil water * tensiometric pressure * xylem tension Subject RIV: DA - Hydrology ; Limnology Impact factor: 0.827, year: 2014

  5. Mobile Disdrometer Observations of Nocturnal Mesoscale Convective Systems During PECAN

    Science.gov (United States)

    Bodine, D. J.; Rasmussen, K. L.

    2015-12-01

    Understanding microphysical processes in nocturnal mesoscale convective systems (MCSs) is an important objective of the Plains Elevated Convection At Night (PECAN) experiment, which occurred from 1 June - 15 July 2015 in the central Great Plains region of the United States. Observations of MCSs were collected using a large array of mobile and fixed instrumentation, including ground-based radars, soundings, PECAN Integrated Sounding Arrays (PISAs), and aircraft. In addition to these observations, three mobile Parsivel disdrometers were deployed to obtain drop-size distribution (DSD) measurements to further explore microphysical processes in convective and stratiform regions of nocturnal MCSs. Disdrometers were deployed within close range of a multiple frequency network of mobile and fixed dual-polarization radars (5 - 30 km range), and near mobile sounding units and PISAs. Using mobile disdrometer and multiple-wavelength, dual-polarization radar data, microphysical properties of convective and stratiform regions of MCSs are investigated. The analysis will also examine coordinated Range-Height Indicator (RHI) scans over the disdrometers to elucidate vertical DSD structure. Analysis of dense observations obtained during PECAN in combination with mobile disdrometer DSD measurements contributes to a greater understanding of the structural characteristics and evolution of nocturnal MCSs.

  6. Factors associated with nocturnal hypoglycemia in at-risk adolescents and young adults with type 1 diabetes.

    Science.gov (United States)

    Wilson, Darrell M; Calhoun, Peter M; Maahs, David M; Chase, H Peter; Messer, Laurel; Buckingham, Bruce A; Aye, Tandy; Clinton, Paula K; Hramiak, Irene; Kollman, Craig; Beck, Roy W

    2015-06-01

    Hypoglycemia remains an impediment to good glycemic control, with nocturnal hypoglycemia being particularly dangerous. Information on major contributors to nocturnal hypoglycemia remains critical for understanding and mitigating risk. Continuous glucose monitoring (CGM) data for 855 nights were studied, generated by 45 subjects 15-45 years of age with hemoglobin A1c (HbA1c) levels of ≤8.0% who participated in a larger randomized study. Factors assessed for potential association with nocturnal hypoglycemia (CGM measurement of <60 mg/dL for ≥30 min) included bedtime blood glucose (BG), exercise intensity, bedtime snack, insulin on board, day of the week, previous daytime hypoglycemia, age, gender, HbA1c level, diabetes duration, daily basal insulin, and daily insulin dose. Hypoglycemia occurred during 221 of 885 (25%) nights and was more frequent with younger age (P<0.001), lower HbA1c levels (P=0.006), medium/high-intensity exercise during the preceding day (P=0.003), and the occurrence of antecedent daytime hypoglycemia (P=0.001). There was a trend for lower bedtime BG levels to be associated with more frequent nocturnal hypoglycemia (P=0.10). Bedtime snack, before bedtime insulin bolus, weekend versus weekday, gender, and daily basal and bolus insulin were not associated with nocturnal hypoglycemia. Awareness that HbA1c level, exercise, bedtime BG level, and daytime hypoglycemia are all modifiable factors associated with nocturnal hypoglycemia may help patients and providers decrease the risk of hypoglycemia at night. Risk for nocturnal hypoglycemia increased in a linear fashion across the range of variables, with no clear-cut thresholds to guide clinicians or patients for any particular night.

  7. Applications of satellite data to the studies of agricultural meteorology, 2: Relationship between air temperature and surface temperature measured by infrared thermal radiometer

    International Nuclear Information System (INIS)

    Horiguchi, I.; Tani, H.; Morikawa, S.

    1985-01-01

    Experiments were performed in order to establish interpretation keys for estimation of air temperature from satellite IR data. Field measurements were carried out over four kinds of land surfaces including seven different field crops on the university campus at Sapporo. The air temperature was compared with the surface temperature measured by infrared thermal radiometer (National ER2007, 8.5-12.5μm) and, also with other meteorological parameters (solar radiation, humidity and wind speed). Also perpendicular vegetation index (PVI) was measured to know vegetation density of lands by ho radio-spectralmeter (Figs. 1 & 2). Table 1 summarizes the measurements taken in these experiments.The correlation coefficients between air temperature and other meteorological parameters for each area are shown in Table 2. The best correlation coefficient for total data was obtained with surface temperature, and it suggests the possibility that air temperature may be estimated by satellite IR data since they are related to earth surface temperatures.Further analyses were done between air temperature and surface temperature measured with thermal infrared radiometer.The following conclusions may be drawn:(1) Air temperature from meteorological site was well correlated to surface temperature of lands that were covered with dense plant and water, for example, grass land, paddy field and rye field (Table 2).(2) The correlation coefficients and the regression equations on grass land, paddy field and rye field were almost the same (Fig. 3). The mean correlation coefficient for these three lands was 0.88 and the regression equation is given in Eq. (2).(3) There was good correlation on bare soil land also, but had large variations (Fig. 3).(4) The correlations on crop fields depend on the density of plant cover. Good correlation is obtained on dense vegetative fields.(5) Small variations about correlation coefficients were obtained for the time of day (Table 3).(6) On the other hand, large

  8. [Urodynamic changes in patients with obstructive sleep apnea-hypopnea syndrome and nocturnal polyuria].

    Science.gov (United States)

    Hu, Ke; Tu, Zuo-sheng; Lü, Sheng-qi; Li, Qing-quan; Chen, Xue-qin

    2011-03-01

    To investigate the urodynamic changes in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) and nocturnal polyuria. From Sept. 2002 to Jun. 2008, 23 patients with nocturnal polyuria were diagnosed as having OSAHS by polysomnography (PSG). The number and output of nocturia, the osmotic pressure and the excretion of Na(+) were recorded during both the PSG night and CPAP titrating night. Plasma levels of brain natriuretic peptide (BNP) and atrial natriuretic peptides (ANP) were also measured at 11PM in the 2 nights and 7AM in the next mornings. Urodynamic studies including urine flow, bladder pressure during filling, pressure-flow study during voiding and urethral pressure were carried out in these patients. Urodynamic studies were performed again after treatment with CPAP for 3 months. PSG showed that the patients with nocturnal polyuria had moderate to severe OSAHS, in which the apnea-hypopnea index (AHI) being 48 ± 15 events per hour. The number of nocturnal voiding during the PSG night was more than that during the CPAP titrating night. During the PSG night, the output of nocturia, the nocturia excretion of Na(+), ANP levels (at 7am in the next morning after PSG night) increased and the osmotic pressure of nocturia decreased. CPAP therapy could reverse these abnormalities. The main characteristics of urodynamics in these patients included weak detrusor contraction, hypoesthesia in filling cystometry, and decreased bladder compliance, and detrusor external sphincter dyssynergia. After 3 months of CPAP treatment, both the motility of the detrusor of bladder and the bladder compliance improved. CPAP therapy can effectively reverse the nocturnal polyuria in OSAHS patients. In OSAHS patients, the features of nocturia, including the changes of output, osmotic pressure and the excretion of Na(+), may be related to the secretion of high-level of ANP. During the course of chronic progressively OSAHS pathophysiology, detrusor function of bladder may be damaged

  9. Self-construing in children with primary mono-symptomatic nocturnal enuresis--an investigation of three measures.

    Science.gov (United States)

    Robinson, Joanne C; Butler, Richard J; Holland, Philip; Doherty-Williams, Dianne

    2003-01-01

    This study aims to measure different aspects of self-construing in children with primary mono-symptomatic nocturnal enuresis. 25 children aged 7-14 years, with nocturnal enuresis were recruited from a paediatric outpatient's unit specialising in enuresis [mean age 10.6 [males], 9.39 [females

  10. Air and Ground Surface Temperature Relations in a Mountainous Basin, Wolf Creek, Yukon Territory

    Science.gov (United States)

    Roadhouse, Emily A.

    The links between climate and permafrost are well known, but the precise nature of the relationship between air and ground temperatures remains poorly understood, particularly in complex mountain environments. Although previous studies indicate that elevation and potential incoming solar radiation (PISR) are the two leading factors contributing to the existence of permafrost at a given location, additional factors may also contribute significantly to the existence of mountain permafrost, including vegetation cover, snow accumulation and the degree to which individual mountain landscapes are prone to air temperature inversions. Current mountain permafrost models consider only elevation and aspect, and have not been able to deal with inversion effects in a systematic fashion. This thesis explores the relationship between air and ground surface temperatures and the presence of surface-based inversions at 27 sites within the Wolf Creek basin and surrounding area between 2001 and 2006, as a first step in developing an improved permafrost distribution TTOP model. The TTOP model describes the relationship between the mean annual air temperature and the temperature at the top of permafrost in terms of the surface and thermal offsets (Smith and Riseborough, 2002). Key components of this model are n-factors which relate air and ground climate by establishing the ratio between air and surface freezing (winter) and thawing (summer) degree-days, thus summarizing the surface energy balance on a seasonal basis. Here we examine (1) surface offsets and (2) freezing and thawing n-factor variability at a number of sites through altitudinal treeline in the southern Yukon. Thawing n-factors (nt) measured at individual sites remained relatively constant from one year to the next and may be related to land cover. During the winter, the insulating effect of a thick snow cover results in higher surface temperatures, while thin snow cover results in low surface temperatures more closely

  11. Air temperature variability in a high-elevation Himalayan catchment

    NARCIS (Netherlands)

    Heynen, Martin; Miles, Evan; Ragettli, Silvan; Buri, Pascal; Immerzeel, Walter W.; Pellicciotti, Francesca

    2016-01-01

    Air temperature is a key control of processes affecting snow and glaciers in high-elevation catchments, including melt, snowfall and sublimation. It is therefore a key input variable to models of land-surface-atmosphere interaction. Despite this importance, its spatial variability is poorly

  12. Eculizumab in Pregnant Patients with Paroxysmal Nocturnal Hemoglobinuria

    NARCIS (Netherlands)

    Kelly, R.J.; Hochsmann, B.; Szer, J.; Kulasekararaj, A.; Guibert, S. de; Roth, A.; Weitz, I.C.; Armstrong, E.; Risitano, A.M.; Patriquin, C.J.; Terriou, L.; Muus, P.; Hill, A.; Turner, M.P.; Schrezenmeier, H.; Peffault de Latour, R.

    2015-01-01

    BACKGROUND: Eculizumab, a humanized monoclonal antibody against complement protein C5 that inhibits terminal complement activation, has been shown to prevent complications of paroxysmal nocturnal hemoglobinuria (PNH) and improve quality of life and overall survival, but data on the use of eculizumab

  13. Innovative Visualizations Shed Light on Avian Nocturnal Migration

    NARCIS (Netherlands)

    Shamoun-Baranes, J.; Farnsworth, A.; Aelterman, B.; Alves, J.A.; Azijn, K.; Bernstein, G.; Branco, S.; Desmet, P.; Dokter, A.M.; Horton, K.; Kelling, S.; Kelly, J.F.; Leijnse, H.; Rong, J.; Sheldon, D.; Van den Broeck, W.; Van Den Meersche, J.K.; Van Doren, B.M.; van Gasteren, H.

    2016-01-01

    Globally, billions of flying animals undergo seasonal migrations, many of which occur at night. The temporal and spatial scales at which migrations occur and our inability to directly observe these nocturnal movements makes monitoring and characterizing this critical period in migratory animals’

  14. Opportunities to Reduce Air-Conditioning Loads Through Lower Cabin Soak Temperatures

    International Nuclear Information System (INIS)

    Farrington, R.; Cuddy, M.; Keyser, M.; Rugh, J.

    1999-01-01

    Air-conditioning loads can significantly reduce electric vehicle (EV) range and hybrid electric vehicle (HEV) fuel economy. In addition, a new U. S. emissions procedure, called the Supplemental Federal Test Procedure (SFTP), has provided the motivation for reducing the size of vehicle air-conditioning systems in the United States. The SFTP will measure tailpipe emissions with the air-conditioning system operating. If the size of the air-conditioning system is reduced, the cabin soak temperature must also be reduced, with no penalty in terms of passenger thermal comfort. This paper presents the impact of air-conditioning on EV range and HEV fuel economy, and compares the effectiveness of advanced glazing and cabin ventilation. Experimental and modeled results are presented

  15. Association between morphometric variables and nocturnal desaturation in sickle-cell anemia.

    Science.gov (United States)

    Salles, Cristina; Bispo, Marcelo; Trindade-Ramos, Regina Terse

    2014-01-01

    to evaluate associations between morphometric variables, cervical circumference (CC), and abdominal circumference (AC) with the presence of nocturnal desaturation in children and adolescents with sickle-cell anemia. all patients were submitted to baseline polysomnography, oral cavity measurements (maxillary intermolar distance, mandibular intermolar distance, and overjet), and CC and AC measurements. a total of 85 patients were evaluated. A positive correlation was observed between the height/age Z-score and CC measurement (r = 0.233, p = 0.031). The presence of nocturnal desaturation was associated with CC (59.2± 9.3 vs. 67.5 ± 10.7, p = 0.006) and AC measurements (27.0 ± 2.0 vs. 29.0± 2.1, p = 0.028). There was a negative correlation between desaturation and maxillary intermolar distance (r = -0.365, p = 0.001) and mandibular intermolar distance (r = -0.233, p = 0.037). the morphometric variables of CC and AC may contribute to raise suspicion of nocturnal desaturation in children and adolescents with sickle-cell anemia. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. Association between morphometric variables and nocturnal desaturation in sickle-cell anemia

    Directory of Open Access Journals (Sweden)

    Cristina Salles

    2014-07-01

    Full Text Available OBJECTIVE: to evaluate associations between morphometric variables, cervical circumference (CC, and abdominal circumference (AC with the presence of nocturnal desaturation in children and adolescents with sickle-cell anemia. METHODS: all patients were submitted to baseline polysomnography, oral cavity measurements (maxillary intermolar distance, mandibular intermolar distance, and overjet, and CC and AC measurements. RESULTS: a total of 85 patients were evaluated. A positive correlation was observed between the height/age Z-score and CC measurement (r = 0.233, p = 0.031. The presence of nocturnal desaturation was associated with CC (59.2± 9.3 vs. 67.5 ± 10.7, p = 0.006 and AC measurements (27.0 ± 2.0 vs. 29.0± 2.1, p = 0.028. There was a negative correlation between desaturation and maxillary intermolar distance (r = -0.365, p = 0.001 and mandibular intermolar distance (r = -0.233, p = 0.037. CONCLUSIONS: the morphometric variables of CC and AC may contribute to raise suspicion of nocturnal desaturation in children and adolescents with sickle-cell anemia.

  17. Improving 7-Day Forecast Skill by Assimilation of Retrieved AIRS Temperature Profiles

    Science.gov (United States)

    Susskind, Joel; Rosenberg, Bob

    2016-01-01

    We conducted a new set of Data Assimilation Experiments covering the period January 1 to February 29, 2016 using the GEOS-5 DAS. Our experiments assimilate all data used operationally by GMAO (Control) with some modifications. Significant improvement in Global and Southern Hemisphere Extra-tropical 7-day forecast skill was obtained when: We assimilated AIRS Quality Controlled temperature profiles in place of observed AIRS radiances, and also did not assimilate CrISATMS radiances, nor did we assimilate radiosonde temperature profiles or aircraft temperatures. This new methodology did not improve or degrade 7-day Northern Hemispheric Extra-tropical forecast skill. We are conducting experiments aimed at further improving of Northern Hemisphere Extra-tropical forecast skill.

  18. Transport coefficients in high-temperature ionized air flows with electronic excitation

    Science.gov (United States)

    Istomin, V. A.; Oblapenko, G. P.

    2018-01-01

    Transport coefficients are studied in high-temperature ionized air mixtures using the modified Chapman-Enskog method. The 11-component mixture N2/N2+/N /N+/O2/O2+/O /O+/N O /N O+/e- , taking into account the rotational and vibrational degrees of freedom of molecules and electronic degrees of freedom of both atomic and molecular species, is considered. Using the PAINeT software package, developed by the authors of the paper, in wide temperature range calculations of the thermal conductivity, thermal diffusion, diffusion, and shear viscosity coefficients for an equilibrium ionized air mixture and non-equilibrium flow conditions for mixture compositions, characteristic of those in shock tube experiments and re-entry conditions, are performed. For the equilibrium air case, the computed transport coefficients are compared to those obtained using simplified kinetic theory algorithms. It is shown that neglecting electronic excitation leads to a significant underestimation of the thermal conductivity coefficient at temperatures higher than 25 000 K. For non-equilibrium test cases, it is shown that the thermal diffusion coefficients of neutral species and the self-diffusion coefficients of all species are strongly affected by the mixture composition, while the thermal conductivity coefficient is most strongly influenced by the degree of ionization of the flow. Neglecting electronic excitation causes noticeable underestimation of the thermal conductivity coefficient at temperatures higher than 20 000 K.

  19. Quantitative demonstration of the efficacy of night-time apomorphine infusion to treat nocturnal hypokinesia in Parkinson's disease using wearable sensors.

    Science.gov (United States)

    Bhidayasiri, Roongroj; Sringean, Jirada; Anan, Chanawat; Boonpang, Kamolwan; Thanawattano, Chusak; Ray Chaudhuri, K

    2016-12-01

    Nocturnal hypokinesia/akinesia is one of the common night-time symptoms in patients with Parkinson's disease (PD), negatively affecting quality of life of patients and caregivers. The recognition of this problem and treatment options are limited in clinical practice. To evaluate the efficacy of nocturnal apomorphine infusion, using a wearable sensor, in patients who are already on daytime continuous subcutaneous apomorphine infusion and still suffer from nocturnal hypokinesia. Nocturnal parameters in 10 PD patients before and during nocturnal infusion were assessed over two nights at their homes, using a wearable sensor (trunk). Nocturnal parameters included number, velocity, acceleration, degree, and duration of rolling over, and number of times they got out of bed. Correlations with validated clinical rating scales were performed. Following nocturnal apomorphine infusion (34.8 ± 6.5 mg per night), there were significant improvements in the number of turns in bed (p = 0.027), turning velocity (p = 0.046), and the degree of turning (p = 0.028) in PD patients. Significant improvements of Modified Parkinson's Disease Sleep Scale (p = 0.005), the axial score of Unified Parkinson's Disease Rating Scale (p = 0.013), and Nocturnal Akinesia Dystonia and Cramp Scale (p = 0.014) were also observed. Our study was able to demonstrate quantitatively the efficacy of nocturnal apomorphine infusion in PD patients with nocturnal hypokinesia and demonstrated the feasibility of using wearable sensors to yield objective and quantifiable outcomes in a clinical trial setting. More studies are needed to determine the long-term efficacy of this treatment in a large prospective cohort of PD patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Global Validation of MODIS Atmospheric Profile-Derived Near-Surface Air Temperature and Dew Point Estimates

    Science.gov (United States)

    Famiglietti, C.; Fisher, J.; Halverson, G. H.

    2017-12-01

    This study validates a method of remote sensing near-surface meteorology that vertically interpolates MODIS atmospheric profiles to surface pressure level. The extraction of air temperature and dew point observations at a two-meter reference height from 2001 to 2014 yields global moderate- to fine-resolution near-surface temperature distributions that are compared to geographically and temporally corresponding measurements from 114 ground meteorological stations distributed worldwide. This analysis is the first robust, large-scale validation of the MODIS-derived near-surface air temperature and dew point estimates, both of which serve as key inputs in models of energy, water, and carbon exchange between the land surface and the atmosphere. Results show strong linear correlations between remotely sensed and in-situ near-surface air temperature measurements (R2 = 0.89), as well as between dew point observations (R2 = 0.77). Performance is relatively uniform across climate zones. The extension of mean climate-wise percent errors to the entire remote sensing dataset allows for the determination of MODIS air temperature and dew point uncertainties on a global scale.

  1. Air injection low temperature oxidation process for enhanced oil recovery from light oil reservoirs

    International Nuclear Information System (INIS)

    Tunio, A.H.; Harijan, K.

    2010-01-01

    This paper represents EOR (Enhanced Oil Recovery) methods to recover unswept oil from depleted light oil reservoirs. The essential theme here is the removal of oxygen at LTO (Low Temperature Oxidation) from the injected air for a light oil reservoir by means of some chemical reactions occurring between oil and oxygen. In-situ combustion process, HTO (High Temperature Oxidation) is not suitable for deep light oil reservoirs. In case of light oil reservoirs LTO is more suitable to prevail as comparative to HTO. Few laboratory experimental results were obtained from air injection process, to study the LTO reactions. LTO process is suitable for air injection rate in which reservoir has sufficiently high temperature and spontaneous reaction takes place. Out comes of this study are the effect of LTO reactions in oxygen consumption and the recovery of oil. This air injection method is economic compared to other EOR methods i.e. miscible hydrocarbon gas, nitrogen, and carbon dioxide flooding etc. This LTO air injection process is suitable for secondary recovery methods where water flooding is not feasible due to technical problems. (author)

  2. Neuropsychological functioning related to specific characteristics of nocturnal enuresis.

    Science.gov (United States)

    Van Herzeele, C; Dhondt, K; Roels, S P; Raes, A; Groen, L-A; Hoebeke, P; Walle, J Vande

    2015-08-01

    There is a high comorbidity demonstrated in the literature between nocturnal enuresis and several neuropsychological dysfunctions, with special emphasis on attention deficit hyperactivity disorder (ADHD). However, the majority of the psychological studies did not include full non-invasive screening and failed to differentiate between monosymptomatic nocturnal enuresis (MNE) and non-MNE patients. The present study primarily aimed to investigate the association between nocturnal enuresis and (neuro)psychological functioning in a selective homogeneous patient group, namely: children with MNE and associated nocturnal polyuria (NP). Secondly, the study investigated the association between specific characteristics of nocturnal enuresis (maximum voided volume, number of wet nights and number of nights with NP) and ADHD-inattentive symptoms, executive functioning and quality of life. The psychological measurements were multi-informant (parents, children and teachers) and multi-method (questionnaires, clinical interviews and neuropsychological testing). Thirty children aged 6-16 years (mean 10.43 years, SD 3.08) were included. Of them, 80% had at least one psychological, motor or neurological difficulty. The comorbid diagnosis of ADHD, especially the predominantly inattentive presentation, was most common. According to the teachers, a low maximum voided volume (corrected for age) was associated with more attention problems, and a high number of nights with NP was associated with more behaviour-regulation problems. No significant correlations were found between specific characteristics of enuresis and quality of life. Details are demonstrated in Table. The children were recruited from a tertiary referral centre, which resulted in selection bias. Moreover, NP was defined as a urine output exceeding 100% of the expected bladder capacity for age (EBC), and not according to the expert-opinion-based International Children's Continence Society norm of 130% of EBC. The definition

  3. Performance evaluation of an air-breathing high-temperature proton exchange membrane fuel cell

    International Nuclear Information System (INIS)

    Wu, Qixing; Li, Haiyang; Yuan, Wenxiang; Luo, Zhongkuan; Wang, Fang; Sun, Hongyuan; Zhao, Xuxin; Fu, Huide

    2015-01-01

    Highlights: • An air-breathing HT-PEMFC was designed and evaluated experimentally. • The peak power density of the air-breathing HT-PEMFC was 220.5 mW cm"−"2 at 200 °C. • Break-in behavior and effects of temperature and anodic stoichiometry were studied. • The effect of cell orientations on the performance was investigated. • The degradation rate of the air-breathing HT-PEMFC was around 58.32 μV h"−"1. - Abstract: The air-breathing proton exchange membrane fuel cell (PEMFC) is of great interest in mobile power sources because of its simple system design and low parasitic power consumption. Different from previous low-temperature air-breathing PEMFCs, a high-temperature PEMFC with a phosphoric acid doped polybenzimidazole (PBI) membrane as the polymer electrolyte is designed and investigated under air-breathing conditions. The preliminary results show that a peak power density of 220.5 mW cm"−"2 at 200 °C can be achieved without employing any water managements, which is comparable to those with conventional Nafion® membranes operated at low temperatures. In addition, it is found that with the present cell design, the limiting current density arising from the oxygen transfer limitation is around 700 mA cm"−"2 even at 200 °C. The short-term durability test at 200 mA cm"−"2 and 180 °C reveals that all the cells exhibit a gradual decrease in the voltage along with a rise in the internal resistance. The degradation rate of continuous operation is around 58.32 μV h"−"1, which is much smaller than those of start/stop cycling operations.

  4. Water infiltration in an aquifer recharge basin affected by temperature and air entrapment

    OpenAIRE

    Loizeau Sébastien; Rossier Yvan; Gaudet Jean-Paul; Refloch Aurore; Besnard Katia; Angulo-Jaramillo Rafael; Lassabatere Laurent

    2017-01-01

    Artificial basins are used to recharge groundwater and protect water pumping fields. In these basins, infiltration rates are monitored to detect any decrease in water infiltration in relation with clogging. However, miss-estimations of infiltration rate may result from neglecting the effects of water temperature change and air-entrapment. This study aims to investigate the effect of temperature and air entrapment on water infiltration at the basin scale by conducting successive infiltration c...

  5. Genetics Home Reference: autosomal dominant nocturnal frontal lobe epilepsy

    Science.gov (United States)

    ... with ADNFLE have experienced psychiatric disorders (such as schizophrenia), behavioral problems, or intellectual disability. It is unclear ... Epilepsy Society Citizens United for Research in Epilepsy (CURE) GeneReviews (1 link) Autosomal Dominant Nocturnal Frontal Lobe ...

  6. Effects of exercise timing on sleep architecture and nocturnal blood pressure in prehypertensives

    Directory of Open Access Journals (Sweden)

    Fairbrother K

    2014-12-01

    Full Text Available Kimberly Fairbrother,1 Ben Cartner,1 Jessica R Alley,1 Chelsea D Curry,1, David L Dickinson,2 David M Morris,1 Scott R Collier1 1Vascular Biology and Autonomic Studies Laboratory, Department of Health and Exercise Science, 2Department of Economics, Appalachian State University, Boone, NC, USA Background: During nocturnal sleep, blood pressure (BP “dips” compared to diurnal BP, reducing stress on the cardiovascular system. Both the hypotensive response elicited by acute aerobic exercise and sleep quality can impact this dipping response. Purpose: The purpose of this study was to investigate the effects of aerobic exercise timing on circadian BP changes and sleep architecture. Materials and methods: Twenty prehypertensive subjects completed the study. During four test sessions, participants first completed a graded exercise test to exhaustion and then performed 30 minutes of treadmill exercise at 7 am (7A, 1 pm (1P, and 7 pm (7P in a random, counterbalanced order at 65% of the heart rate obtained at peak oxygen uptake. An ambulatory cuff was used to monitor BP responses during 24 hours following exercise, and an ambulatory sleep-monitoring headband was worn during sleep following each session. Results: Aerobic exercise at 7A invoked a greater dip in nocturnal systolic BP than exercise at 1P or 7P, although the greatest dip in nocturnal diastolic BP occurred following 7P. Compared to 1P, 7A also invoked greater time spent in deep sleep. Conclusion: These data indicate that early morning may be the most beneficial time to engage in aerobic exercise to enhance nocturnal BP changes and quality of sleep. Keywords: nocturnal dipping, prehypertension, aerobic exercise

  7. Neural organisation in the first optic ganglion of the nocturnal bee Megalopta genalis.

    Science.gov (United States)

    Greiner, Birgit; Ribi, Willi A; Wcislo, William T; Warrant, Eric J

    2004-11-01

    Each neural unit (cartridge) in the first optic ganglion (lamina) of the nocturnal bee Megalopta genalis contains nine receptor cell axons (6 short and 3 long visual fibres), and four different types of first-order interneurons, also known as L-fibres (L1 to L4) or lamina monopolar cells. The short visual fibres terminate within the lamina as three different types (svf 1, 2, 3). The three long visual fibres pass through the lamina without forming characteristic branching patterns and terminate in the second optic ganglion, the medulla. The lateral branching pattern of svf 2 into adjacent cartridges is unique for hymenopterans. In addition, all four types of L-fibres show dorso-ventrally arranged, wide, lateral branching in this nocturnal bee. This is in contrast to the diurnal bees Apis mellifera and Lasioglossum leucozonium, where only two out of four L-fibre types (L2 and L4) reach neighbouring cartridges. In M. genalis, L1 forms two sub-types, viz. L1-a and L1-b; L1-b in particular has the potential to contact several neighbouring cartridges. L2 and L4 in the nocturnal bee are similar to L2 and L4 in the diurnal bees but have dorso-ventral arborisations that are twice as wide. A new type of laterally spreading L3 has been discovered in the nocturnal bee. The extensive neural branching pattern of L-fibres in M. genalis indicates a potential role for these neurons in the spatial summation of photons from large groups of ommatidia. This specific adaptation in the nocturnal bee could significantly improve reliability of vision in dim light.

  8. Nocturnal herbivore-induced plant volatiles attract the generalist predatory earwig Doru luteipes Scudder

    Science.gov (United States)

    Naranjo-Guevara, Natalia; Peñaflor, Maria Fernanda G. V.; Cabezas-Guerrero, Milton F.; Bento, José Maurício S.

    2017-10-01

    Numerous studies have demonstrated that entomophagous arthropods use herbivore-induced plant volatile (HIPV) blends to search for their prey or host. However, no study has yet focused on the response of nocturnal predators to volatile blends emitted by prey damaged plants. We investigated the olfactory behavioral responses of the night-active generalist predatory earwig Doru luteipes Scudder (Dermaptera: Forficulidae) to diurnal and nocturnal volatile blends emitted by maize plants ( Zea mays) attacked by either a stem borer ( Diatraea saccharalis) or a leaf-chewing caterpillar ( Spodoptera frugiperda), both suitable lepidopteran prey. Additionally, we examined whether the earwig preferred odors emitted from short- or long-term damaged maize. We first determined the earwig diel foraging rhythm and confirmed that D. luteipes is a nocturnal predator. Olfactometer assays showed that during the day, although the earwigs were walking actively, they did not discriminate the volatiles of undamaged maize plants from those of herbivore damaged maize plants. In contrast, at night, earwigs preferred volatiles emitted by maize plants attacked by D. saccharalis or S. frugiperda over undamaged plants and short- over long-term damaged maize. Our GC-MS analysis revealed that short-term damaged nocturnal plant volatile blends were comprised mainly of fatty acid derivatives (i.e., green leaf volatiles), while the long-term damaged plant volatile blend contained mostly terpenoids. We also observed distinct volatile blend composition emitted by maize damaged by the different caterpillars. Our results showed that D. luteipes innately uses nocturnal herbivore-induced plant volatiles to search for prey. Moreover, the attraction of the earwig to short-term damaged plants is likely mediated by fatty acid derivatives.

  9. Nocturnality in synapsids predates the origin of mammals by over 100 million years.

    Science.gov (United States)

    Angielczyk, K D; Schmitz, L

    2014-10-22

    Nocturnality is widespread among extant mammals and often considered the ancestral behavioural pattern for all mammals. However, mammals are nested within a larger clade, Synapsida, and non-mammalian synapsids comprise a rich phylogenetic, morphological and ecological diversity. Even though non-mammalian synapsids potentially could elucidate the early evolution of diel activity patterns and enrich the understanding of synapsid palaeobiology, data on their diel activity are currently unavailable. Using scleral ring and orbit dimensions, we demonstrate that nocturnal activity was not an innovation unique to mammals but a character that appeared much earlier in synapsid history, possibly several times independently. The 24 Carboniferous to Jurassic non-mammalian synapsid species in our sample featured eye morphologies consistent with all major diel activity patterns, with examples of nocturnality as old as the Late Carboniferous (ca 300 Ma). Carnivores such as Sphenacodon ferox and Dimetrodon milleri, but also the herbivorous cynodont Tritylodon longaevus were likely nocturnal, whereas most of the anomodont herbivores are reconstructed as diurnal. Recognizing the complexity of diel activity patterns in non-mammalian synapsids is an important step towards a more nuanced picture of the evolutionary history of behaviour in the synapsid clade. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  10. Pure rotational CARS thermometry studies of low-temperature oxidation kinetics in air and ethene-air nanosecond pulse discharge plasmas

    International Nuclear Information System (INIS)

    Zuzeek, Yvette; Choi, Inchul; Uddi, Mruthunjaya; Adamovich, Igor V; Lempert, Walter R

    2010-01-01

    Pure rotational CARS thermometry is used to study low-temperature plasma assisted fuel oxidation kinetics in a repetitive nanosecond pulse discharge in ethene-air at stoichiometric and fuel lean conditions at 40 Torr pressure. Air and fuel-air mixtures are excited by a burst of high-voltage nanosecond pulses (peak voltage, 20 kV; pulse duration, ∼ 25 ns) at a 40 kHz pulse repetition rate and a burst repetition rate of 10 Hz. The number of pulses in the burst is varied from a few pulses to a few hundred pulses. The results are compared with the previously developed hydrocarbon-air plasma chemistry model, modified to incorporate non-empirical scaling of the nanosecond discharge pulse energy coupled to the plasma with number density, as well as one-dimensional conduction heat transfer. Experimental time-resolved temperature, determined as a function of the number of pulses in the burst, is found to agree well with the model predictions. The results demonstrate that the heating rate in fuel-air plasmas is much faster compared with air plasmas, primarily due to energy release in exothermic reactions of fuel with O atoms generated by the plasma. It is found that the initial heating rate in fuel-air plasmas is controlled by the rate of radical (primarily O atoms) generation and is nearly independent of the equivalence ratio. At long burst durations, the heating rate in lean fuel air-mixtures is significantly reduced when all fuel is oxidized.

  11. Observational Insights into N2O5 Heterogeneous Chemistry: Influencing Factors and Contribution to Wintertime Air Pollution

    Science.gov (United States)

    McDuffie, E. E.; Fibiger, D. L.; Womack, C.; Dube, W. P.; Lopez-Hilfiker, F.; Goldberger, L.; Thornton, J. A.; Shah, V.; Jaegle, L.; Guo, H.; Weber, R. J.; Schroder, J. C.; Campuzano Jost, P.; Jimenez, J. L.; Franchin, A.; Middlebrook, A. M.; Baasandorj, M.; Brown, S. S.

    2017-12-01

    Chemical mechanisms that underlie wintertime air pollution, including tropospheric ozone and aerosol nitrate, are poorly characterized. Due to colder temperatures and fewer hours of solar radiation, nocturnal heterogeneous uptake of N2O5 plays a relatively larger role during wintertime in controlling the oxidation of NOx (=NO+NO2) and its influence on ozone and soluble nitrate. After uptake to aerosol, N2O5 can act as both a nocturnal NOx reservoir and sink depending on the partitioning between its nitric acid and photo labile, ClNO2 reaction products. In addition, N2O5 itself can act as a NOx reservoir if the aerosol uptake coefficient is small. As a result, the nocturnal fate of N2O5 dictates the amount of NOx in an air parcel and the subsequent formation of aerosol nitrate and following-day ozone. Models of winter air pollution therefore require accurate parameterization of the N2O5 uptake coefficient, as well as factors that control its magnitude and N2O5 product partitioning. There are currently only a small number of ambient N2O5 and ClNO2 observations during the winter season concurrent with measurements of relevant variables such as aerosol size distributions and composition. The Wintertime INvestigation of Transport, Emissions, and Reactivity (WINTER) campaign conducted 10 nighttime research flights with the NCAR C-130 over the eastern U.S. during February and March, 2015. The more recent Utah Wintertime Fine Particulate Study (UWFPS) conducted over 20 research flights with the NOAA twin otter aircraft during January-February 2017 in three mountain basins near and including Salt Lake City, Utah. The two campaigns were similarly instrumented and have provided the first aircraft observations of N2O5, ClNO2, and aerosol composition in the wintertime boundary layer in these urban-influenced regions. Analysis of heterogeneous chemistry under a wide range of real environmental conditions provides insight into the factors controlling the N2O5 uptake coefficient

  12. Endurance performance and nocturnal HRV indices.

    Science.gov (United States)

    Nummela, A; Hynynen, E; Kaikkonen, P; Rusko, H

    2010-03-01

    The effects of endurance training on endurance performance characteristics and cardiac autonomic modulation during night sleep were investigated. Twenty-four sedentary subjects trained over four weeks two hours per week at an average running intensity of 76+/-4% of their heart rate reserve. The R to R ECG-intervals were recorded and heart rate variability indices including high frequency power (HFP) were calculated for the nights following the training days every week. The subjects were divided into responders and non-responders according to the improvements in the maximal velocity of the incremental treadmill test (v(max)). The responders improved their v(max) by 10.9+/-46 % (p < 0.001) while no changes were observed in the non-responders (1.6+/-3.0%), although there were no differences in any training load variables between the groups. In the responders nocturnal HFP was significantly higher during the fourth training week compared to the first training week (p=0.036). Furthermore, a significant correlation was observed between the change in v(max) and the change in nocturnal HFP (r=0.482, p=0.042). It was concluded that after similar training, an increase in cardiac vagal modulation was related to improved v(max) in the sedentary subjects. Georg Thieme Verlag KG Stuttgart.New York.

  13. The impact of temperature on mean local air age and thermal comfort in a stratum ventilated office

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Lin; Lin, Zhang; Yao, Ting [Building Energy and Environmental Technology Research Unit, School of Energy and Environment and Division of Building Science and Technology, City University of Hong Kong, Hong Kong SAR (China); Liu, Jing; Wang, Qiuwang [State Key Lab of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an, 710049 (China)

    2011-02-15

    The influence of the supply air temperature on the mean local air age and thermal comfort of a typical individual office under stratum ventilation is investigated by a numerical method, which is validated by an experiment carried out by the authors. The results show that for an office, when the supply air temperature is increased from 19 C to 21 C, the corresponding mean occupied zone temperature rises from 24.5 C to 26.5 C. The inhaled air quality for the occupant is improved when supply air temperature rises from 19 C to 21 C. Also, the thermal comfort indices (predicted mean vote or PMV, predicted percentage of dissatisfied or PPD and predicted dissatisfied or PD) fulfill the requirements of ISO 7730 and CR 175 1998. For summer cooling operation, stratum ventilation may offer a feasible solution to elevated indoor temperatures, which are recommended by several governments in East Asia. (author)

  14. Pattern of Primary Nocturnal Enuresis in Primary School Children ...

    African Journals Online (AJOL)

    Pattern of Primary Nocturnal Enuresis in Primary School Children (First Grade) in ... The control group consisting of 100 age-matched non-enuretic children ... was insignificantly associated with a positive family history, family size or birth rank.

  15. Pressure drop in packed beds of spherical particles at ambient and elevated air temperatures

    Directory of Open Access Journals (Sweden)

    Pešić Radojica

    2015-01-01

    Full Text Available The aim of this work was the experimental investigation of the particle friction factor for air flow through packed bed of particles at ambient and elevated temperatures. The experiments were performed by measuring the pressure drop across the packed bed, heated to the desired temperature by hot air. Glass spherical particles of seven different diameters were used. The temperature range of the air flowing through the packed bed was from 20ºC to 350ºC and the bed voidages were from 0.3574 to 0.4303. The obtained results were correlated using a number of available literature correlations. The overall best fit of all of the experimental data was obtained using Ergun [1] equation, with mean absolute deviation of 10.90%. Ergun`s equation gave somewhat better results in correlating the data at ambient temperature with mean absolute deviation of 9.77%, while correlation of the data at elevated temperatures gave mean absolute deviation of 12.38%. The vast majority of the correlations used gave better results when applied to ambient temperature data than to the data at elevated temperatures. Based on the results obtained, Ergun [1] equation is proposed for friction factor calculation both at ambient and at elevated temperatures. [Projekat Ministarstva nauke Republike Srbije, br. ON172022

  16. Artificial light pollution increases nocturnal vigilance in peahens.

    Science.gov (United States)

    Yorzinski, Jessica L; Chisholm, Sarah; Byerley, Sydney D; Coy, Jeanee R; Aziz, Aisyah; Wolf, Jamie A; Gnerlich, Amanda C

    2015-01-01

    Artificial light pollution is drastically changing the sensory environments of animals. Even though many animals are now living in these changed environments, the effect light pollution has on animal behavior is poorly understood. We investigated the effect of light pollution on nocturnal vigilance in peahens (Pavo cristatus). Captive peahens were exposed to either artificial lighting or natural lighting at night. We employed a novel method to record their vigilance behavior by attaching accelerometers to their heads and continuously monitoring their large head movements. We found that light pollution significantly increases nocturnal vigilance in peahens. Furthermore, the birds faced a trade-off between vigilance and sleep at night: peahens that were more vigilant spent less time sleeping. Given the choice, peahens preferred to roost away from high levels of artificial lighting but showed no preference for roosting without artificial lighting or with low levels of artificial lighting. Our study demonstrates that light pollution can have a substantial impact on animal behavior that can potentially result in fitness consequences.

  17. The multidimensional correlates associated with short nocturnal sleep duration and subjective insomnia among Taiwanese adolescents.

    Science.gov (United States)

    Yen, Cheng-Fang; Ko, Chih-Hung; Yen, Ju-Yu; Cheng, Chung-Ping

    2008-11-01

    The aim of this study was to examine the correlates associated with short nocturnal sleep duration and subjective insomnia, including individual factors, family factors, peer factors, school factors, and the problematic use of high-tech devices among a large-scale representative population of Taiwanese adolescents. Cross-sectional study. A total of 23 junior high and 29 senior high/vocational schools were randomly selected across southern Taiwan. Eight thousand four adolescent students. N/A. The multidimensional correlates associated with short nocturnal sleep duration and subjective insomnia were examined using chi2 automatic interaction detection analysis and logistic regression analysis models. The results indicated that an older age, self-reported depression, being in the third year of school, drinking coffee at night, and problematic Internet use were significantly associated with short nocturnal sleep duration in adolescents. Furthermore, self-reported depression, low school affinity, high family conflict, low connectedness to their peer group, and problematic Internet use were associated with subjective insomnia in adolescents. The results of this study indicate that a variety of individual, family, peer, and school factors were associated with short nocturnal sleep duration and subjective insomnia in adolescents. Furthermore, the correlates of short sleep duration were not identical to those of subjective insomnia. Parents and health professionals should be wary of sleep patterns among adolescents who have the identified correlates of short nocturnal sleep duration and subjective insomnia.

  18. Microalbuminuria in patients with non-insulin-dependent diabetes mellitus relates to nocturnal systolic blood pressure.

    LENUS (Irish Health Repository)

    Mitchell, T H

    2012-02-03

    PURPOSE: Microalbuminuria predicts early mortality in non-insulin-dependent-diabetes mellitus patients (NIDDM). Our objective in the present study was to compare and assess the relationship between 24-hour, day and nocturnal ambulatory blood pressure (BP) and urinary albumin excretion rate (UAE) in microalbuminuric and normoalbuminuric NIDDM and in normal control subjects. PATIENTS AND METHODS: In the present cross-sectional study, 24 hour ambulatory BP (daytime BP and nocturnal BP) and HbA1c were compared in microalbuminuric (n = 10) and nonmicroalbuminuric NIDDM patients (n = 10) and in nondiabetic controls (n = 9). None of the patients were taking antihypertensive agents. RESULTS: In the microlbuminuric group, whereas 24 hour and daytime systolic BP differed significantly from control values (P < 0.025 and P < 0.05 respectively), there was no difference between diabetic groups. However, nocturnal systolic BP in the microalbuminuric group was significantly higher than in the normoalbuminuric diabetic patients (139 vs. 125) (P < 0.05) and a significant difference was also found between the NIDDM patients and the control group (139, 125 vs. 114) (P < 0.025). In multiple regression analysis, only nocturnal systolic BP showed a significant relationship with UAE (P < 0.05). CONCLUSIONS: We suggest that the higher nocturnal systolic blood pressure seen in our microalbuminuric NIDDM patients may contribute to the increased morbidity in this group.

  19. The effect of fan speed control system on the inlet air temperature uniformity in a solar dryer

    Directory of Open Access Journals (Sweden)

    S. F Mousavi

    2015-09-01

    Full Text Available Introduction: Drying process of agricultural products, fruits and vegetables are highly energy demanding and hence are the most expensive postharvest operation. Nowadays, the application of control systems in different area of science and engineering plays a key role and is considered as the important and inseparable parts of any industrial process. The review of literature indicates that enormous efforts have been donefor the intelligent control of solar driers and in this regard some simulation models are used through computer programming. However, because of the effect of air velocity on the inlet air temperature in dryers, efforts have been made to control the fan speed based ont he temperature of the absorber plate in this study, and the behavior of this system was compared with an ordinary dryer without such a control system. Materials and methods: In this study, acabinet type solar dryer with forced convection and 5kg capacity of fresh herbs was used. The dryer was equipped with a fan in the outlet chamber (the chimney for creating air flow through the dryer. For the purpose of research methods and automatic control of fan speed and for adjusting the temperature of the drying inlet air, a control system consisting of a series of temperature and humidity sensors and a microcontroller was designed. To evaluatethe effect of the system with fan speed control on the uniformity of air temperature in the drying chamber and hence the trend of drying process in the solar dryer, the dryer has been used with two different modes: with and without the control of fan speed, each in twodays (to minimize the errors of almost the same ambient temperature. The ambient air temperature during the four days of experiments was obtained from the regional Meteorological Office. Some fresh mint plants (Mentha longifolia directly harvested from the farm in the morning of the experiment days were used as the drying materials. Each experimental run continued for 9

  20. Temporal Changes in the Observed Relationship between Cloud Cover and Surface Air Temperature.

    Science.gov (United States)

    Sun, Bomin; Groisman, Pavel Ya.; Bradley, Raymond S.; Keimig, Frank T.

    2000-12-01

    The relationship between cloud cover and near-surface air temperature and its decadal changes are examined using the hourly synoptic data for the past four to six decades from five regions of the Northern Hemisphere: Canada, the United States, the former Soviet Union, China, and tropical islands of the western Pacific. The authors define the normalized cloud cover-surface air temperature relationship, NOCET or dT/dCL, as a temperature anomaly with a unit (one-tenth) deviation of total cloud cover from its average value. Then mean monthly NOCET time series (night- and daytime, separately) are area-averaged and parameterized as functions of surface air humidity and snow cover. The day- and nighttime NOCET variations are strongly anticorrelated with changes in surface humidity. Furthermore, the daytime NOCET changes are positively correlated to changes in snow cover extent. The regionally averaged nighttime NOCET varies from 0.05 K tenth1 in the wet Tropics to 1.0 K tenth1 at midlatitudes in winter. The daytime regional NOCET ranges from 0.4 K tenth1 in the Tropics to 0.7 K tenth1 at midlatitudes in winter.The authors found a general strengthening of a daytime surface cooling during the post-World War II period associated with cloud cover over the United States and China, but a minor reduction of this cooling in higher latitudes. Furthermore, since the 1970s, a prominent increase in atmospheric humidity has significantly weakened the effectiveness of the surface warming (best seen at nighttime) associated with cloud cover.The authors apportion the spatiotemporal field of interactions between total cloud cover and surface air temperature into a bivariate relationship (described by two equations, one for daytime and one for nighttime) with surface air humidity and snow cover and two constant factors. These factors are invariant in space and time domains. It is speculated that they may represent empirical estimates of the overall cloud cover effect on the surface air

  1. Observational analysis of air-sea fluxes and sea water temperature offshore South China Sea

    Science.gov (United States)

    Bi, X.; Huang, J.; Gao, Z.; Liu, Y.

    2017-12-01

    This paper investigates the air-sea fluxes (momentum flux, sensible heat flux and latent heat flux) from eddy covariance method based on data collected at an offshore observation tower in the South China Sea from January 2009 to December 2016 and sea water temperature (SWT) on six different levels based on data collected from November 2011 to June 2013. The depth of water at the tower over the sea averages about 15 m. This study presents the in-situ measurements of continuous air-sea fluxes and SWT at different depths. Seasonal and diurnal variations in air-sea fluxes and SWT on different depths are examined. Results show that air-sea fluxes and all SWT changed seasonally; sea-land breeze circulation appears all the year round. Unlike winters where SWT on different depths are fairly consistent, the difference between sea surface temperature (SST) and sea temperature at 10 m water depth fluctuates dramatically and the maximum value reaches 7 °C during summer.

  2. Hypothetical air ingress scenarios in advanced modular high temperature gas cooled reactors

    International Nuclear Information System (INIS)

    Kroeger, P.G.

    1988-01-01

    Considering an extremely hypothetical scenario of complete cross duct failure and unlimited air supply into the reactor vessel of a modular high temperature gas cooled ractor, it is found that the potential air inflow remains limited due to the high friction pressure drop through the active core. All incoming air will be oxidized to CO and some local external burning would be temporarily possible in such a scenario. The accident would have to continue with unlimited air supply for hundreds of hours before the core structural integrity would be jeopardized

  3. Core temperature in super-Gaussian pumped air-clad photonic ...

    Indian Academy of Sciences (India)

    In this paper we investigate the core temperature of air-clad photonic crystal fiber (PCF) lasers pumped by a super-Gaussian (SG) source of order four. The results are compared with conventional double-clad fiber (DCF) lasers pumped by the same super-Gaussian and by top-hat pump profiles.

  4. Attribution of precipitation changes on ground-air temperature offset: Granger causality analysis

    Czech Academy of Sciences Publication Activity Database

    Čermák, Vladimír; Bodri, L.

    2018-01-01

    Roč. 107, č. 1 (2018), s. 145-152 ISSN 1437-3254 R&D Projects: GA ČR(CZ) GAP210/11/0183; GA MŠk(CZ) LG13040 Institutional support: RVO:67985530 Keywords : geothermics * climate change * ground-air temperature offset * soil temperature * temperature monitoring Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 2.283, year: 2016

  5. Univaried models in the series of temperature of the air

    International Nuclear Information System (INIS)

    Leon Aristizabal Gloria esperanza

    2000-01-01

    The theoretical framework for the study of the air's temperature time series is the theory of stochastic processes, particularly those known as ARIMA, that make it possible to carry out a univaried analysis. ARIMA models are built in order to explain the structure of the monthly temperatures corresponding to the mean, the absolute maximum, absolute minimum, maximum mean and minimum mean temperatures, for four stations in Colombia. By means of those models, the possible evolution of the latter variables is estimated with predictive aims in mind. The application and utility of the models is discussed

  6. Analysis of air temperature changes on blood pressure and heart rate and performance of undergraduate students.

    Science.gov (United States)

    Siqueira, Joseana C F; da Silva, Luiz Bueno; Coutinho, Antônio S; Rodrigues, Rafaela M

    2017-01-01

    The increase in air temperature has been associated with human deaths, some of which are related to cardiovascular dysfunctions, and with the reduction of physical and cognitive performance in humans. To analyze the relationship between blood pressure (BP) and heart rate (HR) and the cognitive performance of students who were submitted to temperature changes in classrooms. The university students answered a survey that was adapted from the Battery of Reasoning Tests over 3 consecutive days at different air temperatures while their thermal state and HR were measured. During those 3 days, BP and HR were evaluated before and after the cognitive test. The average and final HR increased at high temperatures; the tests execution time was reduced at high temperatures; and the cognitive tests was related to Mean BP at the beginning of the test, the maximum HR during the test and the air temperature. The cognitive performance of undergraduate students in the field of engineering and technology will increase while performing activities in a learning environment with an air temperature of approximately 23.3°C (according to their thermal perception), if students have an initial MBP of 93.33 mmHg and a 60 bpm HRmax.

  7. Influence of air temperature variations on incidence of epistaxis.

    Science.gov (United States)

    Comelli, Ivan; Vincenti, Vincenzo; Benatti, Mario; Macri, Gian Franco; Comelli, Denis; Lippi, Giuseppe; Cervellin, Gianfranco

    2015-01-01

    Epistaxis is the most common ear, nose, and throat emergency observed in the emergency department (ED). An increased frequency of this condition has been observed during cooler months, but the results of available studies are controversial. The aim of this study was to investigate the seasonality and association of epistaxis presentations to a large urban ED with variations of air temperature and humidity. This study was a retrospective case series. Information on all the patients who presented for epistaxis in the ED of the Academic Hospital of Parma during the years 2003-2012 and ages ≥ 14 years were retrieved from the hospital data base, excluding those attributable to trauma. The chronologic data of all visits were associated with climate data (air temperature and humidity) by univariate linear regression analysis. Among the 819,596 ED patients seen throughout the observational period, 5404 were admitted for epistaxis. Of these, 5220 were discharged from the ED, whereas 184 (3.4%) needed hospital admission. A strong seasonality of epistaxis was observed, with a peak during winter. A strong negative correlation was also found between the daily number of epistaxes and the mean daily temperature in the whole population as well as in patient subgroups (those undergoing anticoagulant or antiplatelet therapy, or those with hypertension, inherited bleeding disorders, liver cirrhosis, or advanced malignancy). A weaker correlation was also found between air humidity and epistaxis but only in certain subgroups. The results of this study provided a contribution to improve our understanding of the epidemiology of epistaxis and for specific health policies that should also be planned by considering the seasonality of nosebleed.

  8. A shorter snowfall season associated with higher air temperatures over northern Eurasia

    International Nuclear Information System (INIS)

    Ye Hengchun; Cohen, Judah

    2013-01-01

    The temperature sensitivity of the snowfall season (start, end, duration) over northern Eurasia (the former USSR) is analyzed from synoptic records of 547 stations from 1966 to 2000. The results find significant correlations between temperature and snowfall season at approximately 56% of stations (61% for the starting date and 56% for the ending date) with a mean snowfall season duration temperature sensitivity of −6.2 days °C −1 split over the start (2.8 days) and end periods (−3.4 days). Temperature sensitivity was observed to increase with stations’ mean seasonal air temperature, with the strongest relationships at locations of around 6 °C temperature. This implies that increasing air temperature in fall and spring will delay the onset and hasten the end of snowfall events, and reduces the snowfall season length by 6.2 days for each degree of increase. This study also clarifies that the increasing trend in snowfall season length during 1936/37–1994 over northern European Russia and central Siberia revealed in an earlier study is unlikely to be associated with warming in spring and fall seasons. (letter)

  9. The effect of dexlansoprazole MR on nocturnal heartburn and GERD-related sleep disturbances in patients with symptomatic GERD.

    Science.gov (United States)

    Fass, Ronnie; Johnson, David A; Orr, William C; Han, Cong; Mody, Reema; Stern, Kathleen N; Pilmer, Betsy L; Perez, M Claudia

    2011-03-01

    Nocturnal heartburn and related sleep disturbances are common among patients with gastroesophageal reflux disease (GERD). This study evaluated the efficacy of dexlansoprazole MR 30 mg in relieving nocturnal heartburn and GERD-related sleep disturbances, improving work productivity, and decreasing nocturnal symptom severity in patients with symptomatic GERD. Patients (N=305) with frequent, moderate-to-very severe nocturnal heartburn and associated sleep disturbances were randomized 1:1 in a double-blind fashion to receive dexlansoprazole MR or placebo once daily for 4 weeks. The primary end point was the percentage of nights without heartburn. Secondary end points were the percentage of patients with relief of nocturnal heartburn and of GERD-related sleep disturbances over the last 7 days of treatment. At baseline and week 4/final visit, patients completed questionnaires that assessed sleep quality, work productivity, and the severity and impact of nocturnal GERD symptoms. Dexlansoprazole MR 30 mg (n=152) was superior to placebo (n=153) in median percentage of nights without heartburn (73.1 vs. 35.7%, respectively; Pheartburn and GERD-related sleep disturbances (47.5 vs. 19.6%, 69.7 vs. 47.9%, respectively; Pheartburn, in reducing GERD-related sleep disturbances and the consequent impairments in work productivity, and in improving sleep quality/quality of life.

  10. Impacts of rising air temperatures on electric transmission ampacity and peak electricity load in the United States

    Science.gov (United States)

    Bartos, Matthew; Chester, Mikhail; Johnson, Nathan; Gorman, Brandon; Eisenberg, Daniel; Linkov, Igor; Bates, Matthew

    2016-11-01

    Climate change may constrain future electricity supply adequacy by reducing electric transmission capacity and increasing electricity demand. The carrying capacity of electric power cables decreases as ambient air temperatures rise; similarly, during the summer peak period, electricity loads typically increase with hotter air temperatures due to increased air conditioning usage. As atmospheric carbon concentrations increase, higher ambient air temperatures may strain power infrastructure by simultaneously reducing transmission capacity and increasing peak electricity load. We estimate the impacts of rising ambient air temperatures on electric transmission ampacity and peak per-capita electricity load for 121 planning areas in the United States using downscaled global climate model projections. Together, these planning areas account for roughly 80% of current peak summertime load. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with future temperature projections to determine the percent change in rated ampacity. Next, we assess the impact of climate change on electricity load by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We find that by mid-century (2040-2060), increases in ambient air temperature may reduce average summertime transmission capacity by 1.9%-5.8% relative to the 1990-2010 reference period. At the same time, peak per-capita summertime loads may rise by 4.2%-15% on average due to increases in ambient air temperature. In the absence of energy efficiency gains, demand-side management programs and transmission infrastructure upgrades, these load increases have the potential to upset current assumptions about future electricity supply adequacy.

  11. THE INFLUENCE OF EUROPEAN CLIMATE VARIABILITY MECHANISM ON AIR TEMPERATURE IN ROMANIA

    Directory of Open Access Journals (Sweden)

    M. MATEI

    2013-03-01

    Full Text Available The main objective of the present paper is to analyze the temporal and spatial variability of air-temperature in Romania, by using mean air-temperature values provided by the ECA&D project (http://eca.knmi.nl/. These data sets will be filtered by means of the EOF (Empirical Orthogonal Function analysis, which describes various modes of space variability and time coefficient series (PC series. The EOF analysis will also be used to identify the main way of action of the European climate variability mechanism, by using multiple variables in grid points, provided by the National Centre of Atmospheric Research (NCAR, USA. The variables considered here are: sea level pressure (SLP, geopotential height at 500 mb (H500 and air temperature at 850 mb (T850, for the summer and winter seasons. The linear trends and shift points of considered variables are then assessed by means of the Mann-Kendall and Pettitt non-parametric tests. By interpreting the results, we can infer that there is causal relationship between the large-scale analyzed parameters and temperature variability in Romania. These results are consistent with those presented by Busuioc et al., 2010, where the main variation trends of the principal European variables are shown.

  12. Research on Vehicle Temperature Regulation System Based on Air Convection Principle

    Science.gov (United States)

    Zhuge, Muzi; Li, Xiang; Liang, Caifeng

    2018-03-01

    The long time parking outdoors in the summer will lead to too high temperature in the car, and the harmful gas produced by the vehicle engine will stay in the confined space for a long time during the parking process, which will do great harm to the human body. If the air conditioning system is turned on before driving, the cooling rate is slow and the battery loss is large. To solve the above problems, we designed a temperature adjusting system based on the principle of air convection. We can choose the automatic mode or manual mode to achieve control of a convection window. In the automatic mode, the system will automatically detect the environmental temperature, through the sensor to complete the detection, and the signal is transmitted to the microcontroller to control the window open or close, in manual mode, the remote control of the window can be realized by Bluetooth. Therefore, the system has important practical significance to effectively regulate temperature, prolong battery life, and improve the safety and comfort of traffic vehicles.

  13. Nocturnal and Circadian Rhythm of Blood Pressure Is Associated with Renal Structure Damage and Function in Patients with IgAN.

    Science.gov (United States)

    Lin, Lirong; Zhang, Huhai; Yang, Jurong; Zhang, Jianguo; Li, Kailong; Huo, Bengang; Dai, Huanzi; Zhang, Weiwei; Yang, Jie; Tan, Wei; He, Yani

    2016-01-01

    Abnormal circadian rhythm of blood pressure (BP) is closely related to target organ damage in hypertension. However, the association between abnormal circadian rhythm of BP and renal injury is not clear. We investigated whether renal injury is associated with nocturnal BP and circadian rhythm of BP in Chinese IgAN patients. Clinic and 24 h ambulatory BP monitoring data were obtained from 330 Chinese IgAN patients with mean 24 h BP circadian BP, and 27% had nocturnal hypertension with a nondipping pattern. Compared with nocturnal normotensive patients, patients with nocturnal hypertension had significantly higher levels of blood cystatin C, blood uric acid, and lower estimated glomerular filtration rate (eGFR), and significantly a higher mean renal tissue injury score. The nondipping hypertensive group had significantly higher nocturnal diastolic and systolic BP, blood uric acid, and glomerulosclerosis rates, whereas eGFR was lower. In nondipping hypertensive patients, urinary sodium excretion and renal tissue injury scores were significantly higher than dipping patients. Nocturnal hypertension and abnormal circadian BP correlated with renal tissue injury, renal interstitial fibrosis, and aortic arch atherosclerosis. Abnormal circadian rhythm of BP and nocturnal hypertension are common clinical manifestations in Chinese IgAN patients with normal mean 24 h BP. Abnormal circadian BP and nocturnal hypertension may accelerate IgAN progression by inducing renal dysfunction and histopathological damage. Copyright © 2016 IMSS. Published by Elsevier Inc. All rights reserved.

  14. Climate Prediction Center (CPC) Global Land Surface Air Temperature Analysis

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A station observation-based global land monthly mean surface air temperature dataset at 0.5 0.5 latitude-longitude resolution for the period from 1948 to the present...

  15. Climate Prediction Center (CPC) Global Land Surface Air Temperature Analysis

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A station observation-based global land monthly mean surface air temperature dataset at 0.5 x 0.5 latitude-longitude resolution for the period from 1948 to the...

  16. From dusk till dawn: nocturnal and diurnal pollination in the epiphyte Tillandsia heterophylla (Bromeliaceae).

    Science.gov (United States)

    Aguilar-Rodríguez, P A; Krömer, T; García-Franco, J G; MacSwiney G, M C

    2016-01-01

    In order to compare the effectiveness of diurnal and nocturnal pollinators, we studied the reproductive biology and pollinators of Tillandsia heterophylla E. Morren, an epiphytic tank bromeliad endemic to southeastern Mexico. Since anthesis in T. heterophylla is predominantly nocturnal but lasts until the following day, we hypothesised that this bromeliad would receive visits from both diurnal and nocturnal visitors, but that nocturnal visitors would be the most effective pollinators, since they arrive first to the receptive flower, and that bats would be the most frequent nocturnal visitors, given the characteristics of the nectar. Flowering of T. heterophylla began in May and lasted until July. The species is fully self-compatible, with an anthesis that lasts for ca. 15-16 h. Mean volume of nectar produced per flower was 82.21 μl, with a mean sugar concentration of 6.33%. The highest volume and concentration of nectar were found at 20:00 h, with a subsequent decline in both to almost zero over the following 12-h period. T. heterophylla has a generalist pollination system, since at least four different morphospecies of visitors pollinate its flowers: bats, moths, hummingbirds and bees. Most of the pollinating visits corresponded to bats and took place in the early evening, when stigma receptivity had already begun; making bats the probable pollinator on most occasions. However, diurnal pollinators may be important as a 'fail-safe' system by which to guarantee the pollination of T. heterophylla. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  17. The vomeronasal complex of nocturnal strepsirhines and implications for the ancestral condition in primates.

    Science.gov (United States)

    Garrett, Eva C; Dennis, John C; Bhatnagar, Kunwar P; Durham, Emily L; Burrows, Anne M; Bonar, Christopher J; Steckler, Natalie K; Morrison, Edward E; Smith, Timothy D

    2013-12-01

    This study investigates the vomeronasal organ in extant nocturnal strepsirhines as a model for ancestral primates. Cadaveric samples from 10 strepsirhine species, ranging from fetal to adult ages, were studied histologically. Dimensions of structures in the vomeronasal complex, such as the vomeronasal neuroepithelium (VNNE) and vomeronasal cartilage (VNC) were measured in serial sections and selected specimens were studied immunohistochemically to determine physiological aspects of the vomeronasal sensory neurons (VSNs). Osteological features corresponding to vomeronasal structures were studied histologically and related to 3-D CT reconstructions. The VNC consistently rests in a depression on the palatal portion of the maxilla, which we refer to as the vomeronasal groove (VNG). Most age comparisons indicate that in adults VNNE is about twice the length compared with perinatal animals. In VNNE volume, adults are 2- to 3-fold larger compared with perinatal specimens. Across ages, a strong linear relationship exists between VNNE dimensions and body length, mass, and midfacial length. Results indicate that the VNNE of nocturnal strepsirhines is neurogenic postnatally based on GAP43 expression. In addition, based on Olfactory Marker Protein expression, terminally differentiated VSNs are present in the VNNE. Therefore, nocturnal strepsirhines have basic similarities to rodents in growth and maturational characteristics of VSNs. These results indicate that a functional vomeronasal system is likely present in all nocturnal strepsirhines. Finally, given that osteological features such as the VNG are visible on midfacial bones, primate fossils can be assessed to determine whether primate ancestors possessed a vomeronasal complex morphologically similar to that of modern nocturnal strepsirhines. Copyright © 2013 Wiley Periodicals, Inc.

  18. Experimental temperature analysis of simple & hybrid earth air tunnel heat exchanger in series connection at Bikaner Rajasthan India

    Science.gov (United States)

    Jakhar, O. P.; Sharma, Chandra Shekhar; Kukana, Rajendra

    2018-05-01

    The Earth Air Tunnel Heat Exchanger System is a passive air-conditioning system which has no side effect on earth climate and produces better cooling effect and heating effect comfortable to human body. It produces heating effect in winter and cooling effect in summer with the minimum power consumption of energy as compare to other air-conditioning devices. In this research paper Temperature Analysis was done on the two systems of Earth Air Tunnel Heat Exchanger experimentally for summer cooling purpose. Both the system was installed at Mechanical Engineering Department Government Engineering College Bikaner Rajasthan India. Experimental results concludes that the Average Air Temperature Difference was found as 11.00° C and 16.27° C for the Simple and Hybrid Earth Air Tunnel Heat Exchanger in Series Connection System respectively. The Maximum Air Temperature Difference was found as 18.10° C and 23.70° C for the Simple and Hybrid Earth Air Tunnel Heat Exchanger in Series Connection System respectively. The Minimum Air Temperature Difference was found as 5.20° C and 11.70° C for the Simple and Hybrid Earth Air Tunnel Heat Exchanger in Series Connection System respectively.

  19. The Australian Bogong Moth Agrotis infusa: A Long-Distance Nocturnal Navigator

    Directory of Open Access Journals (Sweden)

    Eric Warrant

    2016-04-01

    Full Text Available The nocturnal Bogong moth (Agrotis infusa is an iconic and well-known Australian insect that is also a remarkable nocturnal navigator. Like the Monarch butterflies of North America, Bogong moths make a yearly migration over enormous distances, from southern Queensland, western and northwestern New South Wales (NSW and western Victoria, to the alpine regions of NSW and Victoria. After emerging from their pupae in early spring, adult Bogong moths embark on a long nocturnal journey towards the Australian Alps, a journey that can take many days or even weeks and cover over 1000 km. Once in the Alps (from the end of September, Bogong moths seek out the shelter of selected and isolated high ridge-top caves and rock crevices (typically at elevations above 1800 m. In hundreds of thousands, moths line the interior walls of these cool alpine caves where they “hibernate” over the summer months (referred to as “estivation”. Towards the end of the summer (February and March, the same individuals that arrived months earlier leave the caves and begin their long return trip to their breeding grounds. Once there, moths mate, lay eggs and die. The moths that hatch in the following spring then repeat the migratory cycle afresh. Despite having had no previous experience of the migratory route, these moths find their way to the Alps and locate their estivation caves that are dotted along the high alpine ridges of southeastern Australia. How naïve moths manage this remarkable migratory feat still remains a mystery, although there are many potential sensory cues along the migratory route that moths might rely on during their journey, including visual, olfactory, mechanical and magnetic cues. Here we review our current knowledge of the Bogong moth, including its natural history, its ecology, its cultural importance to the Australian Aborigines and what we understand about the sensory basis of its long-distance nocturnal migration. From this analysis it becomes

  20. Separating selection by diurnal and nocturnal pollinators on floral display and spur length in Gymnadenia conopsea.

    Science.gov (United States)

    Sletvold, Nina; Trunschke, Judith; Wimmergren, Carolina; Agren, Jon

    2012-08-01

    Most plants attract multiple flower visitors that may vary widely in their effectiveness as pollinators. Floral evolution is expected to reflect interactions with the most important pollinators, but few studies have quantified the contribution of different pollinators to current selection on floral traits. To compare selection mediated by diurnal and nocturnal pollinators on floral display and spur length in the rewarding orchid Gymnadenia conopsea, we manipulated the environment by conducting supplemental hand-pollinations and selective pollinator exclusions in two populations in central Norway. In both populations, the exclusion of diurnal pollinators significantly reduced seed production compared to open pollination, whereas the exclusion of nocturnal pollinators did not. There was significant selection on traits expected to influence pollinator attraction and pollination efficiency in both the diurnal and nocturnal pollination treatment. The relative strength of selection among plants exposed to diurnal and nocturnal visitors varied among traits and populations, but the direction of selection was consistent. The results suggest that diurnal pollinators are more important than nocturnal pollinators for seed production in the study populations, but that both categories contribute to selection on floral morphology. The study illustrates how experimental manipulations can link specific categories of pollinators to observed selection on floral traits, and thus improve our understanding of how species interactions shape patterns of selection.

  1. Nocturia in men is a chaotic condition dominated by nocturnal polyuria.

    Science.gov (United States)

    Fujimura, Tetsuya; Yamada, Yuta; Sugihara, Toru; Azuma, Takeshi; Suzuki, Motofumi; Fukuhara, Hiroshi; Nakagawa, Tohru; Kume, Haruki; Igawa, Yasuhiko; Homma, Yukio

    2015-05-01

    To characterize nocturia in men based on frequency volume chart data and symptom profiles assessed using the Core Lower Urinary Tract Symptom Score and Athens Insomnia Scale questionnaires. The Core Lower Urinary Tract Symptom Score and Athens Insomnia Scale questionnaires were administered to 299 consecutive treatment naïve men with nocturia (≥one time per night). Frequency volume chart data were recorded for 2 days. Correlations between nocturia and clinical characteristics including symptom scores, clinical diagnosis, Charlson Comorbidity Index, estimated glomerular filtration rate, uroflowmetry and prostate volume were analyzed. Patients were divided into five groups: one time (n = 36), two times (n = 65), three times (n = 85), four times (n = 78) and five times (n = 34) of nocturia. Age, prevalence or severity of chronic kidney disease, hyperlipidemia, low bladder capacity, nocturnal polyuria, urgency, bladder pain and sleep disorders were significantly correlated with the severity of nocturia. The Spearman correlation analysis identified eight possible independent factors for nocturia: age, estimated glomerular filtration rate, urgency, bladder pain, sleep quality, sleepiness during the day, average voided volume and nocturnal volume divided by body weight. Logistic regression analysis showed that nocturnal volume divided by body weight was the strongest factor of nocturia, and ≥7, 9 and 9.7 mL/kg were practical cut-off values of three, four and five times per night of nocturia, respectively. Nocturia in men is a chaotic condition dominated by nocturnal polyuria, and related to multiple factors including age, renal function, urgency, bladder pain, insomnia and bladder volume. © 2015 The Japanese Urological Association.

  2. Computational fluid dynamic on the temperature simulation of air preheat effect combustion in propane turbulent flame

    Science.gov (United States)

    Elwina; Yunardi; Bindar, Yazid

    2018-04-01

    this paper presents results obtained from the application of a computational fluid dynamics (CFD) code Fluent 6.3 to modelling of temperature in propane flames with and without air preheat. The study focuses to investigate the effect of air preheat temperature on the temperature of the flame. A standard k-ε model and Eddy Dissipation model are utilized to represent the flow field and combustion of the flame being investigated, respectively. The results of calculations are compared with experimental data of propane flame taken from literature. The results of the study show that a combination of the standard k-ε turbulence model and eddy dissipation model is capable of producing reasonable predictions of temperature, particularly in axial profile of all three flames. Both experimental works and numerical simulation showed that increasing the temperature of the combustion air significantly increases the flame temperature.

  3. Translational, rotational and vibrational temperatures of a gliding arc discharge at atmospheric pressure air

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2014-01-01

    and vibrational temperatures of a gliding arc generated at atmospheric pressure air are investigated. Translational temperatures (about 1100 K) were measured by laser-induced Rayleigh scattering, and two-dimensional temperature imaging was performed. Rotational and vibrational temperatures (about 3600 K and 6700...

  4. Gas temperature of capacitance spark discharge in air

    International Nuclear Information System (INIS)

    Ono, Ryo; Nifuku, Masaharu; Fujiwara, Shuzo; Horiguchi, Sadashige; Oda, Tetsuji

    2005-01-01

    Capacitance spark discharge has been widely used for studying the ignition of flammable gas caused by electrostatic discharge. In the present study, the gas temperature of capacitance spark discharge is measured. The gas temperature is an important factor in understanding the electrostatic ignition process because it influences the reaction rate of ignition. Spark discharge is generated in air with a pulse duration shorter than 100 ns. The discharge energy is set to 0.03-1 mJ. The rotational and vibrational temperatures of the N 2 molecule are measured using the emission spectrum of the N 2 second positive system. The rotational and vibrational temperatures are estimated to be 500 and 5000 K, respectively, which are independent of the discharge energy. This result indicates that most of the electron energy is consumed in the excitation of vibrational levels of molecules rather than the heating of the gas. The gas temperature after discharge is also measured by laser-induced fluorescence of OH radicals. It is shown that the gas temperature increases after discharge and reaches approximately 1000 K at 3 μs after discharge. Then the temperature decreases at a rate in the range of 8-35 K/μs depending on the discharge energy

  5. Primary nocturnal enuresis is associated with lower intelligence quotient scores in boys from poorer socioeconomic status families.

    Science.gov (United States)

    Basiri, Abbas; Bahrainian, Seyed Abdolmajid; Khoshdel, Alireza; Jalaly, Niloofar; Golshan, Shabnam; Pakmanesh, Hamid

    2017-03-01

    To explore intelligence quotient in boys with primary nocturnal enuresis compared with normal boys considering their socioeconomic status. A total of 152 school-aged boys (including 55 boys with primary nocturnal enuresis and 97 matched normal controls) were assessed. Boys with a history of any neurological or urological disease were excluded. Two different districts of Tehran: Khani-Abad (a poor district) and Pirouzi (a middle class district) districts were enrolled according to socioeconomic status data reported by the World Health Organization. Intelligence tests were carried out using a validated Iranian translation of the Wechsler Intelligence Scale for Children Revised. Total, as well as performance intelligence quotient and verbal intelligence quotient scores and verbal-performance discrepancy (the difference between verbal and performance intelligence quotient scores for each individual) were compared using a t-test between boys with primary nocturnal enuresis in each district and their matched controls. Considering each district separately, the total intelligence quotient score was lower in primary nocturnal enuresis cases than controls only in the lower income district (90.7 ± 23.3 vs 104.8 ± 14.7, P = 0.002). Similarly, boys with primary nocturnal enuresis ranked lower in verbal intelligence quotient (P = 0.002) and performance intelligence quotient (P = 0.004) compared with their matched normal controls only in lower income district, whereas in the higher income district, boys with primary nocturnal enuresis ranked similar in total intelligence quotient to their matched controls. Boys with primary nocturnal enuresis had a lower intelligence quotient compared with the control participants only in low-income district. It seems important to adjust the results of the intelligence quotient assessment in these children according to their socioeconomic status. © 2017 The Japanese Urological Association.

  6. Glaucomatous Optic Neuropathy Associated with Nocturnal Dip in Blood Pressure: Findings from the Maracaibo Aging Study.

    Science.gov (United States)

    Melgarejo, Jesús D; Lee, Joseph H; Petitto, Michele; Yépez, Juan B; Murati, Felipe A; Jin, Zhezhen; Chávez, Carlos A; Pirela, Rosa V; Calmón, Gustavo E; Lee, Winston; Johnson, Matthew P; Mena, Luis J; Al-Aswad, Lama A; Terwilliger, Joseph D; Allikmets, Rando; Maestre, Gladys E; De Moraes, C Gustavo

    2018-01-05

    To determine which nocturnal blood pressure (BP) parameters (low levels or extreme dipper status) are associated with an increased risk of glaucomatous damage in Hispanics. Observational cross-sectional study. A subset (n = 93) of the participants from the Maracaibo Aging Study (MAS) who met the study eligibility criteria were included. These participants, who were at least 40 years of age, had measurements for optical tomography coherence, visual field (VF) tests, 24-hour BP, office BP, and intraocular pressure 20% compared with daytime BP) were significant risk factors for glaucomatous damage (odds ratio, 19.78 and 5.55, respectively). In this population, the link between nocturnal BP and GON is determined by extreme dipping effects rather than low nocturnal BP levels alone. Further studies considering extreme decreases in nocturnal BP in individuals at high risk of glaucoma are warranted. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Nocturnal polyuria and decreased serum testosterone: is there an association in men with lower urinary tract symptoms?

    Science.gov (United States)

    Kim, Jin Wook; Oh, Mi Mi; Yoon, Cheol Yong; Bae, Jae Hyun; Kim, Je Jong; Moon, Du Geon

    2014-05-01

    To investigate the putative association between nocturia and decreased serum testosterone in men with lower urinary tract symptoms. Frequency volume charts and serum testosterone levels of patients visiting the outpatient clinic for lower urinary tract symptoms were collected and analyzed. Age, prostate volume, body mass index and the presence of comorbidities were accounted for. Frequency volume charts were analyzed for pathophysiological components of nocturnal polyuria, global polyuria, decreased nocturnal bladder capacity and increased frequency to identify associated risks. Frequency volume charts were also used to chart 8-h changes of volume, frequency and capacity to identify time diurnal interactions with risk factors based on serum testosterone levels. A total of 2180 patients were enrolled in the study. Multivariate analysis showed testosterone decreased 0.142 ng/mL for every increase in nocturia, independent of other factors. Logistic regression analysis showed a significant difference between pathophysiological components. Decreased testosterone was shown to carry a significant independent risk for overall nocturia (odds ratio 1.60, 95% confidence interval 1.013-2.527, P = 0.044), and particularly nocturnal polyuria (odds ratio 1.934, 95% confidence interval 1.001-3.737, P = 0.027). Repeated measurement models showed patients with serum testosterone below 2.50 ng/mL to have a paradoxical increase in nocturnal urine volume at night. Nocturia, especially nocturnal polyuria, is associated with decreased serum testosterone. Patients with low serum testosterone show increased nocturnal urine output. © 2013 The Japanese Urological Association.

  8. Use of Quality Controlled AIRS Temperature Soundings to Improve Forecast Skill

    Science.gov (United States)

    Susskind, Joel; Reale, Oreste; Iredell, Lena

    2010-01-01

    AIRS was launched on EOS Aqua on May 4, 2002, together with AMSU-A and HSB, to form a next generation polar orbiting infrared and microwave atmospheric sounding system. The primary products of AIRS/AMSU-A are twice daily global fields of atmospheric temperature-humidity profiles, ozone profiles, sea/land surface skin temperature, and cloud related parameters including OLR. Also included are the clear column radiances used to derive these products which are representative of the radiances AIRS would have seen if there were no clouds in the field of view. All products also have error estimates. The sounding goals of AIRS are to produce 1 km tropospheric layer mean temperatures with an rms error of 1K, and layer precipitable water with an rms error of 20 percent, in cases with up to 90 percent effective cloud cover. The products are designed for data assimilation purposes for the improvement of numerical weather prediction, as well as for the study of climate and meteorological processes. With regard to data assimilation, one can use either the products themselves or the clear column radiances from which the products were derived. The AIRS Version 5 retrieval algorithm is now being used operationally at the Goddard DISC in the routine generation of geophysical parameters derived from AIRS/AMSU data. A major innovation in Version 5 is the ability to generate case-by-case level-by-level error estimates for retrieved quantities and clear column radiances, and the use of these error estimates for Quality Control. The temperature profile error estimates are used to determine a case-by-case characteristic pressure pbest, down to which the profile is considered acceptable for data assimilation purposes. The characteristic pressure p(sub best) is determined by comparing the case dependent error estimate (delta)T(p) to the threshold values (Delta)T(p). The AIRS Version 5 data set provides error estimates of T(p) at all levels, and also profile dependent values of pbest based

  9. Influence of Frequent Nocturnal Home Hemodialysis on Food Preference

    NARCIS (Netherlands)

    Ipema, Karin; Franssen, Casper; van der Schans, Cees; Smit, Lianne; Noordman, Sabine; Haisma, Hinke

    Objective: Dialysis patients frequently report a change of taste that is reversible after renal transplantation, suggesting that uremic toxins may negatively influence taste. Currently, frequent nocturnal home hemodialysis (NHHD) is the most effective method of hemodialysis, and is associated with

  10. Decadal-scale teleconnection between South Atlantic SST and southeast Australia surface air temperature in austral summer

    Science.gov (United States)

    Xue, Jiaqing; Li, Jianping; Sun, Cheng; Zhao, Sen; Mao, Jiangyu; Dong, Di; Li, Yanjie; Feng, Juan

    2018-04-01

    Austral summer (December-February) surface air temperature over southeast Australia (SEA) is found to be remotely influenced by sea surface temperature (SST) in the South Atlantic at decadal time scales. In austral summer, warm SST anomalies in the southwest South Atlantic induce concurrent above-normal surface air temperature over SEA. This decadal-scale teleconnection occurs through the eastward propagating South Atlantic-Australia (SAA) wave train triggered by SST anomalies in the southwest South Atlantic. The excitation of the SAA wave train is verified by forcing experiments based on both linear barotropic and baroclinic models, propagation pathway and spatial scale of the observed SAA wave train are further explained by the Rossby wave ray tracing analysis in non-uniform basic flow. The SAA wave train forced by southwest South Atlantic warming is characterized by an anomalous anticyclone off the eastern coast of the Australia. Temperature diagnostic analyses based on the thermodynamic equation suggest anomalous northerly flows on western flank of this anticyclone can induce low-level warm advection anomaly over SEA, which thus lead to the warming of surface air temperature there. Finally, SST-forced atmospheric general circulation model ensemble experiments also demonstrate that SST forcing in the South Atlantic is associated with the SAA teleconnection wave train in austral summer, this wave train then modulate surface air temperature over SEA on decadal timescales. Hence, observations combined with numerical simulations consistently demonstrate the decadal-scale teleconnection between South Atlantic SST and summertime surface air temperature over SEA.

  11. Air conditioning design temperature - a new proposal; Temperatura de projeto para condicionamento de ar - uma nova proposta

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Jose R.; Cardoso, Sebastiao [Universidade de Taubate, SP (Brazil). Dept. de Engenharia Mecanica]. E-mails: rui@engenh.mec.unitau.br; cardoso@prppg.unitau.br; Travelho, Jeronimo S. [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)]. E-mail: jeff@lac.inpe.br

    2000-07-01

    ABNT - Associacao Brasileira de Normas Tecnicas (Brazilian Association for Technical Standards) - establishes, in NBR-6401, Table 1 (Interior Design Conditions), the dry-bulb summer temperature and the relative humidity to be used in air conditioning design. In thermal comfort plant for residences, hotels, offices and schools these values are, respectively, 23 deg C to 25 deg C and 40% to 60% rh. These data are in accordance with what is recommended by ASHRAE, which was established as a model for North America. This paper presents a new proposal to air conditioning design temperature that takes into consideration Brazilian climatological conditions. The method, named 'effective temperature distribution', compares the maximum recommended effective temperature for each region with dry-bulb temperatures and effective temperatures plotted in a single diagram. This diagram may be used in energetic planning to minimize the use of electric energy for air conditioning. It concludes that the method allows an accuracy analysis about both the temperature levels and the periods of utilization of the air conditioning systems. (author)

  12. Productive and morphogenetic responses of buffel grass at different air temperatures and CO2 concentrations

    Directory of Open Access Journals (Sweden)

    Roberta Machado Santos

    2014-08-01

    Full Text Available The objective of the present trial was to evaluate the productive and morphogenetic characteristics of buffel grass subjected to different air temperatures and CO2 concentrations. Three cultivars of buffel grass (Biloela, Aridus and West Australian were compared. Cultivars were grown in growth chambers at three temperatures (day/night: 26/20, 29/23, and 32/26 °C, combined with two concentrations of CO2: 370 and 550 µmol mol-1. The experimental design was completely randomized, in a 3 × 3 × 2 factorial arrangement with three replications. There were interactions between buffel grass cultivars and air temperatures on leaf elongation rate (LER, leaf appearance rate (LAR, leaf lifespan (LL and senescence rate (SR, whereas cultivars vs. carbon dioxide concentration affected forage mass (FM, root mass (RM, shoot/root ratio, LL and SR. Leaf elongation rate and SR were higher as the air temperature was raised. Increasing air temperature also promoted an increase in LAR, except for West Australian. High CO2 concentration provided greater SR of plants, except for Biloela. Cultivar West Australian had higher FM in relation to Biloela and Aridus when the CO2 concentration was increased to 550 µmol mol-1. West Australian was the only cultivar that responded with more forage mass when it was exposed to higher carbon dioxide concentrations, whereas Aridus had depression in forage mass. The increase in air temperatures affects morphogenetic responses of buffel grass, accelerating its vegetative development without increasing forage mass. Elevated carbon dioxide concentration changes productive responses of buffel grass.

  13. The influence of atmospheric circulation on the air pollution concentration and temperature inversion in Sosnowiec. Case study

    Directory of Open Access Journals (Sweden)

    Widawski Artur

    2015-06-01

    Full Text Available Sosnowiec is located in the Katowice Region, which is the most urbanized and industrialized region in Poland. Urban areas of such character favor enhancement of pollution concentration in the atmosphere and the consequent emergence of smog. Local meteorological and circulation conditions significantly influence not only on the air pollution level but also change air temperature considerably in their centers and immediate vicinities. The synoptic situation also plays the major role in dispersal and concentration of air pollutants and changes in temperature profile. One of the most important are the near-ground (100 m inversions of temperature revealed their highest values on clear winter days and sometimes stay still for the whole day and night. Air temperature inversions in Sosnowiec occur mainly during anticyclone stagnation (Ca-anticyclone centre and Ka-anticyclonic ridge and in anticyclones with air advection from the south and southwest (Sa and SWa which cause significantly increase of air pollution values. The detailed evaluation of the influence of circulation types on the appearance of a particular concentration of pollutants carried out in this work has confirmed the predominant influence of individual circulation types on the development of air pollution levels at the Katowice region. This paper presents research case study results of the thermal structure of the near-ground atmospheric layer (100 m and air pollution parameters (PM10, SO2, NO, NO2 changes in selected days of 2005 year according to regional synoptic circulation types. The changes in urban environment must be taken into account in analyses of multiyear trends of air temperature and air conditions on the regional and global scales.

  14. Bias Correction for Assimilation of Retrieved AIRS Profiles of Temperature and Humidity

    Science.gov (United States)

    Blakenship, Clay; Zavodsky, Bradley; Blackwell, William

    2014-01-01

    The Atmospheric Infrared Sounder (AIRS) is a hyperspectral radiometer aboard NASA's Aqua satellite designed to measure atmospheric profiles of temperature and humidity. AIRS retrievals are assimilated into the Weather Research and Forecasting (WRF) model over the North Pacific for some cases involving "atmospheric rivers". These events bring a large flux of water vapor to the west coast of North America and often lead to extreme precipitation in the coastal mountain ranges. An advantage of assimilating retrievals rather than radiances is that information in partly cloudy fields of view can be used. Two different Level 2 AIRS retrieval products are compared: the Version 6 AIRS Science Team standard retrievals and a neural net retrieval from MIT. Before assimilation, a bias correction is applied to adjust each layer of retrieved temperature and humidity so the layer mean values agree with a short-term model climatology. WRF runs assimilating each of the products are compared against each other and against a control run with no assimilation. Forecasts are against ERA reanalyses.

  15. Hot Air Balloon Experiments to Measure the Break-up of the Nocturnal Drainage Flow in Complex Terrain.

    Science.gov (United States)

    Berman, N. S.; Fernando, H. J. S.; Colomer, J.; Levy, M.; Zieren, L.

    1997-11-01

    In order to extend our understanding of the thermally driven atmospheric winds and their influence on pollutant transport, a hot air balloon experiment was conducted over a four day period in June, 1997 near Nogales, Arizona. The focus was on the early morning break-up of the stable down-slope and down-valley flow and the establishment of a convective boundary layer near the surface in the absence of synoptic winds. Temperature, elevation, position and particulate matter concentration were measured aloft and temperature gradient and wind velocity were measured at ground level. The wind velocity within the stable layer was generally less than 1.5 m/s. Just above the stable layer (about 300 meters above the valley) the wind shifted leading to an erosion of the stable layer from above. Surface heating after sunrise created a convective layer which rose from the ground until the stable layer was destroyed. Examples of temperature fluctuation measurements at various elevations during the establishment of the convective flow will be presented. Implications of results for turbulence parameterizations needed for numerical models of wind fields in complex terrain will be discussed.

  16. Self-reported sleep bruxism and nocturnal gastroesophageal reflux disease in patients with obstructive sleep apnea: relationship to gender and ethnicity.

    Science.gov (United States)

    Hesselbacher, Sean; Subramanian, Shyam; Rao, Shweta; Casturi, Lata; Surani, Salim

    2014-01-01

    Nocturnal bruxism is associated with gastroesophageal reflux disease (GERD), and GERD is strongly associated with obstructive sleep apnea (OSA). Gender and ethnic differences in the prevalence and clinical presentation of these often overlapping sleep disorders have not been well documented. Our aim was to examine the associations between, and the symptoms associated with, nocturnal GERD and sleep bruxism in patients with OSA, and to examine the influence of gender and ethnicity. A retrospective chart review was performed of patients diagnosed with OSA at an academic sleep center. The patients completed a sleep questionnaire prior to undergoing polysomnography. Patients with confirmed OSA were evaluated based on gender and ethnicity. Associations were determined between sleep bruxism and nocturnal GERD, and daytime sleepiness, insomnia, restless legs symptoms, and markers of OSA severity in each group. In these patients with OSA, the prevalence of nocturnal GERD (35%) and sleep bruxism (26%) were higher than the general population. Sleep bruxism was more common in Caucasians than in African Americans or Hispanics; there was no gender difference. Nocturnal GERD was similar among all gender and ethnic groups. Bruxism was associated with nocturnal GERD in females, restless legs symptoms in all subjects and in males, sleepiness in African Americans, and insomnia in Hispanics. Nocturnal GERD was associated with sleepiness in males and African Americans, insomnia in females, and restless legs symptoms in females and in Caucasians. Patients with OSA commonly have comorbid sleep bruxism and nocturnal GERD, which may require separate treatment. Providers should be aware of differences in clinical presentation among different ethnic and gender groups.

  17. Annular air space effects on nuclear waste canister temperatures in a deep geologic waste repository

    International Nuclear Information System (INIS)

    Lowry, W.E.; Cheung, H.; Davis, B.W.

    1980-01-01

    Air spaces in a deep geologic repository for nuclear high level waste will have an important effect on the long-term performance of the waste package. The important temperature effects of an annular air gap surrounding a high level waste canister are determined through 3-D numerical modeling. Air gap properties and parameters specifically analyzed and presented are the air gap size, surfaces emissivity, presence of a sleeve, and initial thermal power generation rate; particular emphasis was placed on determining the effect of these variables have on the canister surface temperature. Finally a discussion based on modeling results is presented which specifically relates the results to NRC regulatory considerations

  18. Room air temperature affects occupants' physiology, perceptions and mental alertness

    Energy Technology Data Exchange (ETDEWEB)

    Tham, Kwok Wai; Willem, Henry Cahyadi [Department of Building, School of Design and Environment, National University of Singapore, 4 Architecture Drive, Singapore 117566 (Singapore)

    2010-01-15

    Thermal environment that causes thermal discomfort may affect office work performance. However, the mechanisms through which occupants are affected are not well understood. This study explores the plausible mechanism linking room air temperature and mental alertness through perceptual and physiological responses in the tropics. Ninety-six young adults participated as voluntary subjects in a series of experiment conducted in the simulated office settings. Three room air temperatures, i.e. 20.0, 23.0 and 26.0 C were selected as the experimental conditions. Both thermal comfort and thermal sensation changed significantly with time under all exposures (P < 0.0001). Longer exposure at 20.0 C led to cooling sensations due to lower skin temperatures (P < 0.0001) and was perceived as the least comfortable. Nevertheless, this moderate cold exposure induced nervous system activation as demonstrated by the increase of {alpha}-Amylase level (P < 0.0001) and the Tsai-partington test (P < 0.0001). A mechanism linking thermal environment, occupants' responses and performance is proposed. (author)

  19. STRATEGY WATER-BASED CONDENSER : An Experimental Scale Model for Hybrid Passive Cooling Systems to Improve Indoor Temperature and Hot Water Utilities in Surabaya-Indonesia

    Directory of Open Access Journals (Sweden)

    Danny Santoso Mintorogo

    2003-01-01

    Full Text Available This paper makes a case of energy saving research, to system water-based condenser for the use of energy efficient with involvement of forced fluid hybrid passive cooling and water heating in building systems. Our argument is based on the fact that series of water copper pipes are to be cooled enough by nocturnal radiant cooling of the night cool air to lower the indoor air temperature at the daytime. We describe the model of working to which we use and to which we believe that series of cool water copper pipes as evaporator allows effectively reducing the energy used for indoor cooling and for water heating utilization. We then measure the model indoor temperature, and water temperature inside the series of copper pipes. Kinds of water coolant used for cooling are an essential factor. Finally, we will discuss some of the achieving of the effective cooled water, setting up the pipes water-based condenser hybrid system on the top of the outside roof as well as setting up the evaporator coils at ceiling. Abstract in Bahasa Indonesia : Penulisan ini merupakan suatu penelitian pada golongan sistem penghematan energi yang berupakan kondensor dengan bahan media air dengan bantuan tenaga gerak pompa atau tanpa tenaga pompa air. Pipa-pipa yang berisi air yang diletakkan diatas atap terbuka untuk mendapatkan air yang dingin melalui proses konduksi, konveksi, dan radiasi dari udara alami sepanjang malam, dimana media air yang telah dingin tersebut untuk dimanfaatkan sebagai media pendingin ruangan dengan melalukan ke pipa-pipa dalam ruangan--diatas plafon, sebagai evapurator. Selain media air akan diteliti air pendingin radiator (water coolent apakah akan mendapatkan efek pendinginan yang melebihi media air. Juga akan diteliti cara proses mendapatkan media air dingin, yaitu proses dengan air tenang (still water dan air bergerak (forced fluid, sistim mana yang lebih efektif dalam mendapatkan media air dingin dan percepatan mendapatkan air dingin. Kata

  20. Using Machine learning method to estimate Air Temperature from MODIS over Berlin

    Science.gov (United States)

    Marzban, F.; Preusker, R.; Sodoudi, S.; Taheri, H.; Allahbakhshi, M.

    2015-12-01

    Land Surface Temperature (LST) is defined as the temperature of the interface between the Earth's surface and its atmosphere and thus it is a critical variable to understand land-atmosphere interactions and a key parameter in meteorological and hydrological studies, which is involved in energy fluxes. Air temperature (Tair) is one of the most important input variables in different spatially distributed hydrological, ecological models. The estimation of near surface air temperature is useful for a wide range of applications. Some applications from traffic or energy management, require Tair data in high spatial and temporal resolution at two meters height above the ground (T2m), sometimes in near-real-time. Thus, a parameterization based on boundary layer physical principles was developed that determines the air temperature from remote sensing data (MODIS). Tair is commonly obtained from synoptic measurements in weather stations. However, the derivation of near surface air temperature from the LST derived from satellite is far from straight forward. T2m is not driven directly by the sun, but indirectly by LST, thus T2m can be parameterized from the LST and other variables such as Albedo, NDVI, Water vapor and etc. Most of the previous studies have focused on estimating T2m based on simple and advanced statistical approaches, Temperature-Vegetation index and energy-balance approaches but the main objective of this research is to explore the relationships between T2m and LST in Berlin by using Artificial intelligence method with the aim of studying key variables to allow us establishing suitable techniques to obtain Tair from satellite Products and ground data. Secondly, an attempt was explored to identify an individual mix of attributes that reveals a particular pattern to better understanding variation of T2m during day and nighttime over the different area of Berlin. For this reason, a three layer Feedforward neural networks is considered with LMA algorithm

  1. Nocturnality constrains morphological and functional diversity in the eyes of reef fishes

    Directory of Open Access Journals (Sweden)

    Schmitz Lars

    2011-11-01

    Full Text Available Abstract Background Ambient light levels are often considered to drive the evolution of eye form and function. Diel activity pattern is the main mechanism controlling the visual environment of teleost reef fish, with day-active (diurnal fish active in well-illuminated conditions, whereas night-active (nocturnal fish cope with dim light. Physiological optics predicts several specific evolutionary responses to dim-light vision that should be reflected in visual performance features of the eye. Results We analyzed a large comparative dataset on morphological traits of the eyes in 265 species of teleost reef fish in 43 different families. The eye morphology of nocturnal reef teleosts is characterized by a syndrome that indicates better light sensitivity, including large relative eye size, high optical ratio and large, rounded pupils. Improved dim-light image formation comes at the cost of reduced depth of focus and reduction of potential accommodative lens movement. Diurnal teleost reef fish, released from the stringent functional requirements of dim-light vision have much higher morphological and optical diversity than nocturnal species, with large ranges of optical ratio, depth of focus, and lens accommodation. Conclusions Physical characteristics of the environment are an important factor in the evolution and diversification of the vertebrate eye. Both teleost reef fish and terrestrial amniotes meet the functional requirements of dim-light vision with a similar evolutionary response of morphological and optical modifications. The trade-off between improved dim-light vision and reduced optical diversity may be a key factor in explaining the lower trophic diversity of nocturnal reef teleosts.

  2. Quantifying the local influence at a tall tower site in nocturnal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Werth, David; Buckley, Robert; Zhang, Gengsheng; Kurzeja, Robert; Leclerc, Monique; Duarte, Henrique; Parker, Matthew; Watson, Thomas

    2015-10-17

    The influence of the local terrestrial environment on nocturnal atmospheric CO2 measurements at a 329-m television transmitter tower (and a component of a CO2 monitoring network) was estimated with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released on two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (~24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. The contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.

  3. Measuring Air Temperature in Glazed Ventilated Facades in the Presence of Direct Solar Radiation

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Zanghirella, Fabio; Heiselberg, Per

    2007-01-01

    A distinctive element of buildings with a double glazed façade is naturally or mechanically driven flow in a ventilated cavity. Accurate air temperature measurements in the cavity are crucial to evaluate the dynamic performance of the façade, to predict and control its behavior as a significant...... part of the complete ventilation system. Assessment of necessary cooling/heating loads and of the whole building energy performance will then depend on the accuracy of measured air temperature. The presence of direct solar radiation is an essential element for the façade operation, but it can heavily...... affect measurements of air temperature and may lead to errors of high magnitude using bare thermocouples and even adopting shielding devices. Two different research groups, from Aalborg University and Politecnico di Torino, tested separately various techniques to shield thermocouples from direct...

  4. MONITORING CANOPY AND AIR TEMPERATURE OF DOMINANT VEGETATION IN TROPICAL SEMI-ARID USING BIOCLIMATIC MODEL

    Directory of Open Access Journals (Sweden)

    Josiclêda Domiciano Galvíncio

    2016-10-01

    Full Text Available Typical vegetation of arid environments consist of few dominant species highly threatened by climate change. Jurema preta (Mimosa tenuiflora (Willd. Poiret is one of these successful species that now is dominant in extensive semiarid areas in the world. The development of a simple bioclimatic model using climate change scenarios based on optimistic and pessimistic predictions of the Intergovernmental Panel on Climate Change (IPCC shown as a simple tool to predict possible responses of dominant species under dry land conditions and low functional biodiversity. The simple bioclimatic model proved satisfactory in creating climate change scenarios and impacts on the canopy temperature of Jurema preta in semiarid Brazil. The bioclimatic model was efficient to obtain spatially relevant estimations of air temperature from determinations of the surface temperature using satellite images. The model determined that the average difference of 5oC between the air temperature and the leaf temperature for Jurema preta, and an increase of 3oC in air temperature, promote an increase of 2oC in leaf temperature. It lead to disturbances in vital physiological mechanisms in the leaf, mainly the photosynthesis and efficient use of water.

  5. Study and realization of a new humid air generator; towards the definition of a dew temperature reference; Etude et realisation d'un nouveau generateur d'air humide; vers la definition d'une reference en temperature de rosee

    Energy Technology Data Exchange (ETDEWEB)

    Blanquart, B.

    2001-03-01

    The air humidity is an important parameter for several biological and physico-chemical processes. The aim of this thesis is the direct determination of the dew temperature without any link with the gravimetric reference. This document presents the realization and adjusting of a new humid air generator for the -80 deg. C to +15 deg. C range and the uncertainty linked with the dew temperature of the humid air generated. The first chapter recalls the definitions of humid air related data and the principles of the apparatuses used for the measurement of air humidity. The second chapter deals with temperature measurements while chapter 3 describes the new humid air generator built around an 'ideal' cell based on the theoretical definition of the dew temperature. Technical constraints due to temperature measurement and to hygrometers calibration are progressively integrated and introduced and lead to the practical realization of the device. Differences between the ideal cell and the prototype are estimated using a theoretical approach of mass and heat exchanges coupled with experimental results obtained with a previous prototype. Chapter 4 presents a first status of the device uncertainties with some possibilities of reduction of these uncertainties. (J.S.)

  6. Creep of Sylramic-iBN Fiber Tows at Elevated Temperature in Air and in Silicic Acid-Saturated Steam

    Science.gov (United States)

    2015-06-01

    CREEP OF SYLRAMIC-iBN FIBER TOWS AT ELEVATED TEMPERATURE IN AIR AND IN SILICIC ACID-SATURATED STEAM ...protection in the United States. AFIT-ENY-15-J-46 CREEP OF SYLRAMIC-iBN FIBER TOWS AT ELEVATED TEMPERATURE IN AIR AND IN SILICIC ACID-SATURATED STEAM ...DISTRIBUTION UNLIMITED. AFIT-ENY-15-J-46 CREEP OF SYLRAMIC-iBN FIBER TOWS AT ELEVATED TEMPERATURE IN AIR AND IN SILICIC ACID-SATURATED STEAM

  7. [Is nocturnal polyuria more frequent among patients with Parkinson's disease?].

    Science.gov (United States)

    Romain, J; Torny, F; Dumas, J-P; Gamé, X; Descazeaud, A

    2015-05-01

    Nocturia is a frequent complaint in the population of idiopathic Parkinson's disease patients (IPD). The consequences of nocturia in the IPD population are at high importance as these patients have motor problems and therefore a risk of nocturnal fall. The aim of the study was to determine the mechanism of nocturia in patients with MPI, by determining the prevalence of nocturnal polyuria (NP) in this population. A prospective study by bladder diary was conducted on 70 consecutive IPD patients consulting for regular neurological follow-up at a non-severe stage. Nocturia was defined as 1 or more awakenings to urinate. Two definitions of NP were used: nocturnal diuresis 33% or higher of the total diuresis (NUV33), which is the ICS (International Continence Society) definition, and nocturnal diuresis 90 mL/h or higher (NUP90). The mean patient age was 71 years (45-86, sex ratio 33/30). On average, patients were diagnosed for IPD 6.76 years earlier. The prevalence of NP was 64.5% according to NUV33 definition, and 17.7% according to NUP90 definition. Among patients with nocturia, the prevalence of NP was 66% (NUV33) and 21.5% (NUP90). No association was observed between disease duration of the IPD and the prevalence of nocturia and NP. Patients 70 years and older were more likely to have NP as defined by NUV33 than those less than 70 years (72.7% versus 55.17%, P=0.015). Men had more frequently nocturia (33.3% versus 20.7%, P=0.027). The prevalence of NP and nocturia was analyzed in patients with IPD at a non-severe stage. This prevalence was not higher than in the general population of the same age. The mechanism of nocturia in patients with IPD is not unambiguous and therefore requires to be explored by a bladder diary. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  8. Prediction of air temperature for thermal comfort of people using sleeping bags: a review.

    Science.gov (United States)

    Huang, Jianhua

    2008-11-01

    Six models for determining air temperatures for thermal comfort of people using sleeping bags were reviewed. These models were based on distinctive metabolic rates and mean skin temperatures. All model predictions of air temperatures are low when the insulation values of the sleeping bag are high. Nevertheless, prediction variations are greatest for the sleeping bags with high insulation values, and there is a high risk of hypothermia if an inappropriate sleeping bag is chosen for the intended conditions of use. There is, therefore, a pressing need to validate the models by wear trial and determine which one best reflects ordinary consumer needs.

  9. Measurements of KrF laser-induced O2 fluorescence in high-temperature atmospheric air

    Science.gov (United States)

    Grinstead, Jay H.; Laufer, Gabriel; Mcdaniel, James C., Jr.

    1993-01-01

    Conditions for obtaining laser-induced O2 fluorescence using a tunable KrF laser has been determined theoretically and experimentally. With this laser source, O2 rotational temperature measurement is possible even in the absence of vibrational equilibrium. Temperature measurement using a two-line excitation scheme has been demonstrated in a high-temperature atmospheric-air furnace. A measurement uncertainty of 10.7 percent for the temperature range 1325-1725 K was realized. At atmospheric pressure, O2 LIF measurements are possible for air temperatures above 1250 K. Interference from OH fluorescence in reacting flows can be avoided by the proper selection of O2 transitions. Depletion of the ground state population by the incident laser is negligible for intensities below 7.5 x 10 to the 6th W/sq cm/per cm.

  10. Sibelius: Luonnotar. Chevauchee nocturne et lever du soleil / Pierre Gervasoni

    Index Scriptorium Estoniae

    Gervasoni, Pierre

    1996-01-01

    Uuest heliplaadist "Sibelius: Luonnotar. Chevauchee nocturne et lever du soleil. 4 Legendes. Orchestre Philharmonique Royal de Stockholm, Paavo Järvi. Virgin Classics 545 213-2 (CD:167F). 1996. TT: 1h 13'22"

  11. Design and evaluation of an inexpensive radiation shield for monitoring surface air temperatures

    Science.gov (United States)

    Zachary A. Holden; Anna E. Klene; Robert F. Keefe; Gretchen G. Moisen

    2013-01-01

    Inexpensive temperature sensors are widely used in agricultural and forestry research. This paper describes a low-cost (~3 USD) radiation shield (radshield) designed for monitoring surface air temperatures in harsh outdoor environments. We compared the performance of the radshield paired with low-cost temperature sensors at three sites in western Montana to several...

  12. Validation of farm-scale methane emissions using nocturnal boundary layer budgets

    Directory of Open Access Journals (Sweden)

    J. Stieger

    2015-12-01

    Full Text Available This study provides the first experimental validation of Swiss agricultural methane emission estimates at the farm scale. We measured CH4 concentrations at a Swiss farmstead during two intensive field campaigns in August 2011 and July 2012 to (1 quantify the source strength of livestock methane emissions using a tethered balloon system and (2 to validate inventory emission estimates via nocturnal boundary layer (NBL budgets. Field measurements were performed at a distance of 150 m from the nearest farm buildings with a tethered balloon system in combination with gradient measurements at eight heights on a 10 m tower to better resolve the near-surface concentrations. Vertical profiles of air temperature, relative humidity, CH4 concentration, wind speed, and wind direction showed that the NBL was strongly influenced by local transport processes and by the valley wind system. Methane concentrations showed a pronounced time course, with highest concentrations in the second half of the night. NBL budget flux estimates were obtained via a time–space kriging approach. Main uncertainties of NBL budget flux estimates were associated with nonstationary atmospheric conditions and the estimate of the inversion height zi (top of volume integration. The mean NBL budget fluxes of 1.60 ± 0.31 μg CH4 m-2 s-1 (1.40 ± 0.50 and 1.66 ± 0.20 μg CH4 m-2 s-1 in 2011 and 2012 respectively were in good agreement with local inventory estimates based on current livestock number and default emission factors, with 1.29 ± 0.47 and 1.74 ± 0.63 μg CH4 m-2 s-1 for 2011 and 2012 respectively. This indicates that emission factors used for the national inventory reports are adequate, and we conclude that the NBL budget approach is a useful tool to validate emission inventory estimates.

  13. Validation of farm-scale methane emissions using nocturnal boundary layer budgets

    Science.gov (United States)

    Stieger, J.; Bamberger, I.; Buchmann, N.; Eugster, W.

    2015-12-01

    This study provides the first experimental validation of Swiss agricultural methane emission estimates at the farm scale. We measured CH4 concentrations at a Swiss farmstead during two intensive field campaigns in August 2011 and July 2012 to (1) quantify the source strength of livestock methane emissions using a tethered balloon system and (2) to validate inventory emission estimates via nocturnal boundary layer (NBL) budgets. Field measurements were performed at a distance of 150 m from the nearest farm buildings with a tethered balloon system in combination with gradient measurements at eight heights on a 10 m tower to better resolve the near-surface concentrations. Vertical profiles of air temperature, relative humidity, CH4 concentration, wind speed, and wind direction showed that the NBL was strongly influenced by local transport processes and by the valley wind system. Methane concentrations showed a pronounced time course, with highest concentrations in the second half of the night. NBL budget flux estimates were obtained via a time-space kriging approach. Main uncertainties of NBL budget flux estimates were associated with nonstationary atmospheric conditions and the estimate of the inversion height zi (top of volume integration). The mean NBL budget fluxes of 1.60 ± 0.31 μg CH4 m-2 s-1 (1.40 ± 0.50 and 1.66 ± 0.20 μg CH4 m-2 s-1 in 2011 and 2012 respectively) were in good agreement with local inventory estimates based on current livestock number and default emission factors, with 1.29 ± 0.47 and 1.74 ± 0.63 μg CH4 m-2 s-1 for 2011 and 2012 respectively. This indicates that emission factors used for the national inventory reports are adequate, and we conclude that the NBL budget approach is a useful tool to validate emission inventory estimates.

  14. Temperature-related mortality estimates after accounting for the cumulative effects of air pollution in an urban area.

    Science.gov (United States)

    Stanišić Stojić, Svetlana; Stanišić, Nemanja; Stojić, Andreja

    2016-07-11

    To propose a new method for including the cumulative mid-term effects of air pollution in the traditional Poisson regression model and compare the temperature-related mortality risk estimates, before and after including air pollution data. The analysis comprised a total of 56,920 residents aged 65 years or older who died from circulatory and respiratory diseases in Belgrade, Serbia, and daily mean PM10, NO2, SO2 and soot concentrations obtained for the period 2009-2014. After accounting for the cumulative effects of air pollutants, the risk associated with cold temperatures was significantly lower and the overall temperature-attributable risk decreased from 8.80 to 3.00 %. Furthermore, the optimum range of temperature, within which no excess temperature-related mortality is expected to occur, was very broad, between -5 and 21 °C, which differs from the previous findings that most of the attributable deaths were associated with mild temperatures. These results suggest that, in polluted areas of developing countries, most of the mortality risk, previously attributed to cold temperatures, can be explained by the mid-term effects of air pollution. The results also showed that the estimated relative importance of PM10 was the smallest of four examined pollutant species, and thus, including PM10 data only is clearly not the most effective way to control for the effects of air pollution.

  15. Effects of desmopressin for the treatment of nocturnal polyuria in elderly women: impact on related sleep quality

    Science.gov (United States)

    Mun, Jong-Hyeon; Kim, Sun-Ouck; Yu, Ho Song; Chung, Ho Suck; Kwon, Dongdeuk

    2015-01-01

    Introduction: We investigated the efficacy, safety, and impact of desmopressin on quality of sleep in treating nocturnal polyuria in elderly women. Methods: We recruited 60 women over 60 years old with lower urinary tract symptoms (LUTS), including nocturia, and with nocturnal polyuria. Nocturnal polyuria was defined as nighttime urine production exceeding 33% of the 24-hour total urine volume determined by a frequency volume (FV) chart. All patients failed to respond to treatment of their underlying disease and evening fluid restriction. Desmopressin 0.1 mg was administered orally at bedtime for 12 weeks. The participants completed a series of questionnaires on the Medical Outcomes Study (MOS) sleep scale and FV chart before and after treatment. Results: The patient population had a mean age of 69.2 ± 9.4 years (range: 61–81). The mean duration of symptoms was 61.2 ± 45.1 months. Significant decreases were evident after desmopressin treatment in the number of nocturia episodes (3.63 ± 1.61 to 2.00 ± 1.13, p = 0.01), nocturnal urine volume (p = 0.01), nocturnal polyuria index (NPI) (p = 0.01), and nocturia index (NI) p = 0.01). Among the categories of the MOS sleep scale, sleep index (p = 0.003), sleep disturbance (p = 0.001), snoring (p = 0.028), and shortness of breath (p = 0.036) significantly changed, with a decreased number of nocturia episodes. Adverse events were mild. Conclusions: Desmopressin is an effective treatment for nocturnal polyuria in elderly women, where conservative treatment has failed. Sleep quality is also improved. PMID:26600882

  16. Correlation between δ18O in precipitation and surface air temperature on different time-scale in China

    International Nuclear Information System (INIS)

    Zhang Lin; Chen Zongyu; Nie Zhenlong; Liu Fuliang; Jia Yankun; Zhang Xiangyang

    2008-01-01

    The relation between isotopic compositions of precipitation and surface air temperature provides a unique tool for paleoclimate studies, among which the relation between long term changes in δ 18 O of precipitation and surface air temperature at different stations or in a given location seems to be the most appropriate to paleoclimatic reconstructions. Analysis was conducted on monthly and annual mean δ 18 O content of precipitation and surface air temperature at spatial and fixed locations by using the data of China (1985-2002) in Global Network of Isotopes in Precipitation (GNIP) Database. This study shows that there is a positive correlation between δ 18 O of precipitation and surface air temperature for stations located in north of 34 degree-36 degree N latitudes. The seasonal δ 18 O-temperature gradient derived from the monthly data of 12 stations in northern China is about 0.034% degree C -1 . The δ 18 O-temperature gradient, however, derived from the long term annual mean data of 13 stations, is about 0.052% degree C -1 , which is substantially larger than the seasonal gradient. (authors)

  17. Artificial light pollution increases nocturnal vigilance in peahens

    Directory of Open Access Journals (Sweden)

    Jessica L. Yorzinski

    2015-08-01

    Full Text Available Artificial light pollution is drastically changing the sensory environments of animals. Even though many animals are now living in these changed environments, the effect light pollution has on animal behavior is poorly understood. We investigated the effect of light pollution on nocturnal vigilance in peahens (Pavo cristatus. Captive peahens were exposed to either artificial lighting or natural lighting at night. We employed a novel method to record their vigilance behavior by attaching accelerometers to their heads and continuously monitoring their large head movements. We found that light pollution significantly increases nocturnal vigilance in peahens. Furthermore, the birds faced a trade-off between vigilance and sleep at night: peahens that were more vigilant spent less time sleeping. Given the choice, peahens preferred to roost away from high levels of artificial lighting but showed no preference for roosting without artificial lighting or with low levels of artificial lighting. Our study demonstrates that light pollution can have a substantial impact on animal behavior that can potentially result in fitness consequences.

  18. Bonding to dentin as a function of air-stream temperatures for solvent evaporation

    Directory of Open Access Journals (Sweden)

    Andréia Aquino Marsiglio

    2012-06-01

    Full Text Available This study evaluated the influence of solvent evaporation conditions of acid-etching adhesives. The medium dentin of thirty extracted human third molars was exposed and bonded to different types of etch-and-rinse adhesives: 1 Scotchbond Multi-Purpose (SBMP ; water-based; 2 Adper Single Bond 2 (SB ; ethanol/water-based, and 3 Prime & Bond 2.1 (PB ; acetone-based. Solvents were evaporated at air-drying temperatures of 21ºC or 38ºC. Composite buildups were incrementally constructed. After storage in water for 24 h at 37ºC, the specimens were prepared for bond strength testing. Data were analyzed by two-way ANOVA and Tukey's test (5%. SBMP performed better when the solvents were evaporated at a higher temperature (p < 0.05. Higher temperatures did not affect the performance of SB or PB. Bond strength at room temperature was material-dependent, and air-drying temperatures affected bonding of the water-based, acid-etching adhesive.

  19. Mean atmospheric temperature model estimation for GNSS meteorology using AIRS and AMSU data

    Directory of Open Access Journals (Sweden)

    Rata Suwantong

    2017-03-01

    Full Text Available In this paper, the problem of modeling the relationship between the mean atmospheric and air surface temperatures is addressed. Particularly, the major goal is to estimate the model parameters at a regional scale in Thailand. To formulate the relationship between the mean atmospheric and air surface temperatures, a triply modulated cosine function was adopted to model the surface temperature as a periodic function. The surface temperature was then converted to mean atmospheric temperature using a linear function. The parameters of the model were estimated using an extended Kalman filter. Traditionally, radiosonde data is used. In this paper, satellite data from an atmospheric infrared sounder, and advanced microwave sounding unit sensors was used because it is open source data and has global coverage with high temporal resolution. The performance of the proposed model was tested against that of a global model via an accuracy assessment of the computed GNSS-derived PWV.

  20. The Role of Auxiliary Variables in Deterministic and Deterministic-Stochastic Spatial Models of Air Temperature in Poland

    Science.gov (United States)

    Szymanowski, Mariusz; Kryza, Maciej

    2017-02-01

    Our study examines the role of auxiliary variables in the process of spatial modelling and mapping of climatological elements, with air temperature in Poland used as an example. The multivariable algorithms are the most frequently applied for spatialization of air temperature, and their results in many studies are proved to be better in comparison to those obtained by various one-dimensional techniques. In most of the previous studies, two main strategies were used to perform multidimensional spatial interpolation of air temperature. First, it was accepted that all variables significantly correlated with air temperature should be incorporated into the model. Second, it was assumed that the more spatial variation of air temperature was deterministically explained, the better was the quality of spatial interpolation. The main goal of the paper was to examine both above-mentioned assumptions. The analysis was performed using data from 250 meteorological stations and for 69 air temperature cases aggregated on different levels: from daily means to 10-year annual mean. Two cases were considered for detailed analysis. The set of potential auxiliary variables covered 11 environmental predictors of air temperature. Another purpose of the study was to compare the results of interpolation given by various multivariable methods using the same set of explanatory variables. Two regression models: multiple linear (MLR) and geographically weighted (GWR) method, as well as their extensions to the regression-kriging form, MLRK and GWRK, respectively, were examined. Stepwise regression was used to select variables for the individual models and the cross-validation method was used to validate the results with a special attention paid to statistically significant improvement of the model using the mean absolute error (MAE) criterion. The main results of this study led to rejection of both assumptions considered. Usually, including more than two or three of the most significantly

  1. The influence of periodic increases of human activity on crepuscular and nocturnal mammals: Testing the weekend effect.

    Science.gov (United States)

    Nix, Joshua H; Howell, Ryan G; Hall, Lucas K; McMillan, Brock R

    2018-01-01

    Human recreation can negatively affect wildlife, particularly on weekends when human activity is highest (i.e., the weekend effect). Much of what we understand about the weekend effect is based on research conducted on diurnal species, which have greater temporal overlap with humans. Because nocturnal species generally avoid times when humans are active, they are likely less affected by anthropogenic activity on weekends. Our objective was to test the weekend effect in relation to the degree of nocturnality of mammals in a recreational area. We predicted that as nocturnality increased, the effect of human activity would decrease. To address our objective, we placed 50 remote cameras along the Diamond Fork River in Utah from January to June 2015. We found that three out of the four focal species supported our predictions. Mule deer (crepuscular) reduced activity throughout our entire study area during weekends and avoided campgrounds. Beavers and mountain lions (both nocturnal) did not negatively respond to increased human activity. Raccoons (nocturnal) reduced activity during weekends, but only within campground areas. Our findings indicate that as the temporal overlap increases between wildlife and humans, so does the influence that humans have on wildlife. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Seasonal Variations of Indoor Microbial Exposures and Their Relation to Temperature, Relative Humidity, and Air Exchange Rate

    DEFF Research Database (Denmark)

    Frankel, Mika; Bekö, Gabriel; Timm, Michael

    2012-01-01

    with temperature, relative humidity, and air exchange rates in Danish homes. Airborne inhalable dust was sampled in five Danish homes throughout the four seasons of 1 year (indoors, n = 127; outdoors, n = 37). Measurements included culturable fungi and bacteria, endotoxin, N-acetyl-beta-d-glucosaminidase, total...... inflammatory potential, particles (0.75 to 15 μm), temperature, relative humidity, and air exchange rates. Significant seasonal variation was found for all indoor microbial exposures, excluding endotoxin. Indoor fungi peaked in summer (median, 235 CFU/m3) and were lowest in winter (median, 26 CFU/m3). Indoor...... of inhalable dust and number of particles. Temperature and air exchange rates were positively associated with fungi and N-acetyl-beta-d-glucosaminidase and negatively with bacteria and the total inflammatory potential. Although temperature, relative humidity, and air exchange rates were significantly...

  3. Navigational efficiency of nocturnal Myrmecia ants suffers at low light levels.

    Directory of Open Access Journals (Sweden)

    Ajay Narendra

    Full Text Available Insects face the challenge of navigating to specific goals in both bright sun-lit and dim-lit environments. Both diurnal and nocturnal insects use quite similar navigation strategies. This is despite the signal-to-noise ratio of the navigational cues being poor at low light conditions. To better understand the evolution of nocturnal life, we investigated the navigational efficiency of a nocturnal ant, Myrmecia pyriformis, at different light levels. Workers of M. pyriformis leave the nest individually in a narrow light-window in the evening twilight to forage on nest-specific Eucalyptus trees. The majority of foragers return to the nest in the morning twilight, while few attempt to return to the nest throughout the night. We found that as light levels dropped, ants paused for longer, walked more slowly, the success in finding the nest reduced and their paths became less straight. We found that in both bright and dark conditions ants relied predominantly on visual landmark information for navigation and that landmark guidance became less reliable at low light conditions. It is perhaps due to the poor navigational efficiency at low light levels that the majority of foragers restrict navigational tasks to the twilight periods, where sufficient navigational information is still available.

  4. USE OF THREE-COMPONENT LEVODOPA (LEVODOPA/CARBIDOPA/ENTACAPONE TO CORRECT NOCTURNAL SYMPTOMS OF PARKINSON,S DISEASE

    Directory of Open Access Journals (Sweden)

    T. K. Kulua

    2015-01-01

    Full Text Available Objective: to describe a clinical case of late-stage Parkinson’s disease (PD with nocturnal symptoms and fluctuations and to present successful experience in using the three-component drug Stalevo (levodopa/carbidopa/entacapone as a single dose prior to sleep. Patient V. aged 72 years took medical advice at the Department of Neurology, Russian Medical Academy of Postgraduate Education, for complaints of constrained movements, inability to turn in bed independently, painful muscle cramps, light sleep with nocturnal awakenings, and frequent (5–6 times urinations at night. The first symptoms of the disease appeared 12 years ago when the patient began to notice sluggishness, altered handwriting, and clumsiness during small movements of the right hand. By taking into account symptoms (obvious nocturnal akinesia, overactive bladder, sleep disorders, and cramps and the results of his examination, the patient was diagnosed with the akinetic-rigid form of PD (4 Hoehn-Yarh scores. Therapy was corrected as follows: the dose of amantadine remained the same (300 mg; its last administration is recommended to be at 16:00; the daily dose of levodopa was 700 mg; that of levodopa/benserazide was 550 mg/day (1 tablet × 3/4 tablet × 1 tablet. The evening intake of levodopa was changed for that of the three-component drug Stalevo (levodopa 150 mg/ carbidopa 37.5 mg/entacapone 200 mg. Results. After 3 months, the patient was observed to have significant health improvement: reduced nocturnal and morning akinesia, better gait, a considerably smaller number of nocturnal urinations (less than once per night, regression of painful calf muscle cramps, and improved sleep. Conclusion. The three-component drug Stalevo (levodopa/carbidopa/entacapone is effective in treating late-stage PD. Its use as a single dose before going to bed has led to regressive nocturnal symptoms, better sleep, and lower motor fluctuations. 

  5. Climate Prediction Center (CPC) U.S. Daily Minimum Air Temperature Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Observational reports of daily air temperature (1200 UTC to 1200 UTC) are made by members of the NWS Automated Surface Observing Systems (ASOS) network; NWS...

  6. Climate Prediction Center (CPC) U.S. Daily Maximum Air Temperature Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Observational reports of daily air temperature (1200 UTC to 1200 UTC) are made by members of the NWS Automated Surface Observing Systems (ASOS) network; NWS...

  7. Effect of Inlet-Air Temperature on Physico-Chemical and Sensory ...

    African Journals Online (AJOL)

    Preliminary investigation carried out on this study showed that samples produced at air inlet temperatures below 200oC exhibited wet and agglomerated particles. The recovered powdered samples were analyzed for proximate composition, pH, available lysine, total solids, pack bulk density, viscosity, solubility and ...

  8. Constraints of using thermostatic expansion valves to operate air-cooled chillers at lower condensing temperatures

    International Nuclear Information System (INIS)

    Yu, F.W.; Chan, K.T.; Chu, H.Y.

    2006-01-01

    Thermostatic expansion valves (TXVs) have long been used in air-cooled chillers to implement head pressure control under which the condensing temperature is kept high at around 50 o C by staging condenser fans as few as possible. This paper considers how TXVs prevent the chillers from operating with an increased COP at lower condensing temperatures when the chiller load or outdoor temperature drops. An analysis on an existing air-cooled reciprocating chiller showed that the range of differential pressures across TXVs restricts the maximum heat rejection airflow required to increase the chiller COP, though the set point of condensing temperature is reduced to 22 o C from a high level of 45 o C. It is possible to use electronic expansion valves to meet the differential pressure requirements for maximum chiller COP. There is a maximum of 28.7% increase in the chiller COP when the heat rejection airflow is able to be maximized in various operating conditions. The results of this paper emphasize criteria for lowering the condensing temperature to enhance the performance of air-cooled chillers

  9. Research on the impacts of air temperature on the evolution of nanosecond pulse discharge products

    International Nuclear Information System (INIS)

    Yu, Jin-lu; He, Li-ming; Ding, Wei; Zhao, Zi-chen; Zhang, Hua-lei

    2016-01-01

    Highlights: • Most of the O_2 particles become O_2(V1) in high temperature. • The O_3 molecules are produced mainly by decayed O atoms. • NO molecules are obtained by decayed N_2(A3), N(2D) and N(2P) at the first stage, NO molecules are obtained by decayed N atoms at last. - Abstract: Based on nonequilibrium plasma dynamics of air discharge, the kinetic model simulating plasma discharge products induced by nanosecond pulse discharge in air is presented in this work. Then the paper compares the calculation of model with experimental results of references, and verifies the accuracy of the model. The evolution characteristics of nanosecond pulse discharge plasma under different air temperatures are obtained. Because the O, O_3 and NO have close relationship with the combustion, their formation mechanisms are discussed especially. With increasing temperature, there is no significant addition in O atoms and O_3 molecules. It is found that most of the O_2 molecules become O_2(V1) in higher temperature. The decreasing time of the O atoms is in accordance with the increasing time of O_3 molecules. Thus, the O_3 molecules are produced mainly by decayed O atoms. Increased air temperature will not produce more active particles which could assist the combustion. With the increasing temperature, the particle number density of NO increases fast. At last, they have reached an equilibrium value of the same.

  10. Combined effects of air temperature, wind, and radiation on the resting metabolism of avian raptors

    International Nuclear Information System (INIS)

    Hayes, S.R.

    1978-01-01

    American kestrels, Falco sparverius; red-tailed hawks, Buteo jamaicensis; and golden eagles, Aquila chrysaetos, were perched in a wind tunnel and subjected to various combinations of air temperature, wind, and radiation. Oxygen consumption was measured under the various combinations of environmental variables, and multiple regression equations were developed to predict resting metabolism as a function of body mass, air temperature, wind speed, and radiation load

  11. Nocturnal raptors (owls: contributions to study of its popularity

    Directory of Open Access Journals (Sweden)

    Maria Lindelia Rincón Hernández

    2017-01-01

    Full Text Available This research characterizes the nocturnal birds of prey on the campus of Universidad Pedagógica y Tecnológica de Colombia (UPTC; in English, Pedagogical and Technological University of Colombia, in addition to the contribution to the study of its popularity, with students in fifth grade from two educational institutions, one, of the urban context, and other, of the rural context. The study involved the implementation of the didactic component to promote recognition of their biological significance in elementary school students. Among the findings two species of nocturnal birds of prey were identified: common currucutú owl (Tropical Screech Owl, Megascops choliba and the barn owl (Tyto alba, with a relative abundance of 12 individuals and 10 individuals, respectively. It also includes changes in perception from students regarding beliefs and superstitions about such species, which favors the recognition of the biological role in the ecosystem and the need for its conservation.

  12. Lower air temperature is associated with ambulance transports and death in Takamatsu area, Japan.

    Science.gov (United States)

    Mochimasu, Kazumi Dokai; Miyatake, Nobuyuki; Tanaka, Naoko; Kinoshita, Hiroshi

    2014-07-01

    The aim of this study was to investigate the linkage among ambulance transports, the number of death and air temperature in Takamatsu area, Japan. Monthly data of ambulance transports (total and acute disease) and the number of death from 2004 to 2012 were obtained from Fire Department Service in Takamatsu and Takamatsu city official website, Japan. Climate parameters for required period were also obtained from Japan Meteorological Agency. Population data in Takamatsu area were also used to adjust ambulance transports and the number of death. The linkage among ambulance transports, the number of death and climate parameters was evaluated by ecological analysis. Total ambulance transports (/a hundred thousand people/day) and ambulance transports due to acute disease (/a hundred thousand people/day) were 12.3 ± 0.9 and 6.8 ± 0.7, respectively. The number of death (/a hundred thousand people/day) was 2.5 ± 0.4. By quadratic curve, ambulance transports due to acute disease and the number of death were significantly correlated with the parameters of air temperature. However, the number of death was the highest in January and the lowest in August. Although higher air temperature was only associated with higher ambulance transports, lower air temperature was associated with both higher ambulance transports and the number death in Takamatsu area, Japan.

  13. Synchronous NDVI and Surface Air Temperature Trends in Newfoundland: 1982 to 2003

    Science.gov (United States)

    Neigh, C. S. R.; Tucker, C. J.; Townshend, J. R. G.

    2007-01-01

    The northern regions of the earth are currently experiencing rapid change in temperature and precipitation. This region contains -40% of carbon stored in the world's soil which has accumulated from the last ice age (over 10,000 years ago). The carbon has remained to this point due to reduced decomposition from the short growing seasons and subfreezing temperatures. The influence of climate upon plant growth can have significant consequences to the carbon cycle balance in this region and could potentially alter and release this long term store of carbon to the atmosphere, resulting in a negative feedback enhancing climate warming. These changes have the potential to alter ecosystems processes, which impact human well being. This paper investigated a global satellite record of increases in vegetation growth from 1982 to 2003 developed at GSFC. It was found that, Newfoundland's vegetation growth during the 1990s exceeded global measurements. A number of potential causes were investigated to understand the mechanistic environmental drivers that could alter the productivity of this ecosystem. Possible drivers of change included: human influence of land use change on vegetation cover; changes in precipitation; temperature; cloud cover; snow cover; and growing season length. We found that humans had a minimal influence on vegetation growth in Newfoundland. Less than 6% of the island was logged during the investigation. We found a strong correlation of vegetation growth to a lengthening of the growing season of -9 and -17 days from 1982-1990 and 1991-1999. A distinct drop in plant growth and air temperature was found in 1990 to 1991 from the volcanic eruption of Mt. Pinatubo that reduced global surface air temperatures. These results document the influences of air temperature upon northern forest plant growth and the cooling effects of major volcanic eruptions in this ecological system.

  14. Artificial light and nocturnal activity in gammarids

    Directory of Open Access Journals (Sweden)

    Elizabeth K. Perkin

    2014-03-01

    Full Text Available Artificial light is gaining attention as a potential stressor to aquatic ecosystems. Artificial lights located near streams increase light levels experienced by stream invertebrates and we hypothesized light would depress night drift rates. We also hypothesized that the effect of light on drift rates would decrease over time as the invertebrates acclimated to the new light level over the course of one month’s exposure. These hypotheses were tested by placing Gammarus spp. in eight, 75 m × 1 m artificial flumes. One flume was exposed to strong (416 lx artificial light at night. This strong light created a gradient between 4.19 and 0.04 lx over the neighboring six artificial flumes, while a control flume was completely covered with black plastic at night. Night-time light measurements taken in the Berlin area confirm that half the flumes were at light levels experienced by urban aquatic invertebrates. Surprisingly, no light treatment affected gammarid drift rates. In contrast, physical activity measurements of in situ individually caged G. roeseli showed they increased short-term activity levels in nights of complete darkness and decreased activity levels in brightly lit flumes. Both nocturnal and diurnal drift increased, and day drift rates were unexpectadly higher than nocturnal drift.

  15. The effect of lateral decubitus position on nocturnal intraocular pressure over a habitual 24-hour period in healthy adults.

    Science.gov (United States)

    Hao, Jie; Zhen, Yi; Wang, Hao; Yang, Diya; Wang, Ningli

    2014-01-01

    To investigate the effect of lateral decubitus position (LDP) on nocturnal intraocular pressure (IOP) and the effect of LDP on 24-hour habitual IOP pattern in healthy subjects. Intraocular pressure was measured every 2-hours using an Accupen Applanation Tonometer (Accutome, USA). During the diurnal period (7:30 am, 9:30 am, 11:30 am, 1:30 pm, 3:30 pm, 5:30 pm, 7:30 pm, and 9:30 pm), IOP was measured in the sitting position under bright light (500-1000 lux) after the subjects had been seated for 5 min. The nocturnal IOP was measured in the supine position, right LDP, and left LDP, with randomized sequences, under dim light (hour habitual IOP patterns were obtained according to the nocturnal position (supine, right LDP and left LDP) for either eye. Phour period, the effect of LDP on habitual IOP pattern was not statistically significant, although the mean nocturnal IOP and the diurnal-nocturnal IOP change for the right and the left eye in the LDP pattern was slightly higher than that in the sitting-supine pattern. Significant nocturnal IOP differences existed between the dependent eye and the supine, but did not occur consistently for all time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant in healthy subjects.

  16. Social support and nocturnal blood pressure dipping: a systematic review.

    Science.gov (United States)

    Fortmann, Addie L; Gallo, Linda C

    2013-03-01

    Attenuated nocturnal blood pressure (BP) dipping is a better predictor of cardiovascular disease (CVD) morbidity and mortality than resting BP measurements. Studies have reported associations between social support, variously defined, and BP dipping. A systematic review of the literature was conducted to investigate associations of functional and structural social support with nocturnal BP dipping assessed over a minimum of 24 hours. A total of 297 articles were identified. Of these, 11 met criteria for inclusion; all studies were cross-sectional in design and included adult participants only (mean age = 19 to 72 years). Evidence was most consistent for an association between functional support and BP dipping, such that 5 of 7 studies reported statistically (or marginally) significant positive associations with BP dipping. Statistically significant functional support-BP dipping associations were moderate (standardized effect size (d) = 0.41) to large (d = 2.01) in magnitude. Studies examining structural support were fewer and relatively less consistent; however, preliminary evidence was observed for associations of marital status and social contact frequency with BP dipping. Statistically significant structural support findings were medium (d = 0.53) to large (d = 1.13) in magnitude. Overall, findings suggest a link between higher levels of functional support and greater nocturnal BP dipping; preliminary evidence was also observed for the protective effects of marriage and social contact frequency. Nonetheless, the relatively small number of studies conducted to date and the heterogeneity of findings across meaningful subgroups suggest that additional research is needed to substantiate these conclusions.

  17. Slow nocturnal home hemodialysis (SNHHD)--one year later.

    Science.gov (United States)

    Ouwendyk, M; Pierratos, A; Francoeur, R; Wallace, L; Sit, W; Vas, S

    1996-01-01

    High costs and overcrowding of dialysis centres are leading to a global crisis in health care provision. We are developing slow nocturnal home hemodialysis (SNHHD) in which patients dialyze for eight to 10 hours during sleep five to seven nights per week. Vascular access is by means of the Cook silastic jugular catheter. Special precautions are taken to prevent accidental disconnection and air embolism. Dialysis functions are remotely monitored on computer via a modem by trained staff. Five patients have completed five to seven weeks of training and have been successfully performing SNHHD single-handedly (three out of five patients live alone) for 14, 14, 11, 10 and four months respectively. All have discontinued their phosphate binders and increased dietary phosphate intake. Compared with conventional hemodialysis (CHD) results, average pre-dialysis urea and creatinine levels are remarkably reduced to 9.6 mmol/l and 486 umol/l respectively. The average cumulative weekly Kt/V for CHD is 5.0 as compared to 7.7 while on SNHHD. Four out of five patients report sleeping soundly and experience greatly increased energy and stamina. Their days are entirely free. Repeated in-situ re-use of the dialyzer and blood lines will reduce the patient's work and make SNHHD a very inexpensive modality. SNHHD appears to be a widely applicable treatment with many advantages to both the patient and the health care system.

  18. Performance of the air2stream model that relates air and stream water temperatures depends on the calibration method

    Science.gov (United States)

    Piotrowski, Adam P.; Napiorkowski, Jaroslaw J.

    2018-06-01

    A number of physical or data-driven models have been proposed to evaluate stream water temperatures based on hydrological and meteorological observations. However, physical models require a large amount of information that is frequently unavailable, while data-based models ignore the physical processes. Recently the air2stream model has been proposed as an intermediate alternative that is based on physical heat budget processes, but it is so simplified that the model may be applied like data-driven ones. However, the price for simplicity is the need to calibrate eight parameters that, although have some physical meaning, cannot be measured or evaluated a priori. As a result, applicability and performance of the air2stream model for a particular stream relies on the efficiency of the calibration method. The original air2stream model uses an inefficient 20-year old approach called Particle Swarm Optimization with inertia weight. This study aims at finding an effective and robust calibration method for the air2stream model. Twelve different optimization algorithms are examined on six different streams from northern USA (states of Washington, Oregon and New York), Poland and Switzerland, located in both high mountains, hilly and lowland areas. It is found that the performance of the air2stream model depends significantly on the calibration method. Two algorithms lead to the best results for each considered stream. The air2stream model, calibrated with the chosen optimization methods, performs favorably against classical streamwater temperature models. The MATLAB code of the air2stream model and the chosen calibration procedure (CoBiDE) are available as Supplementary Material on the Journal of Hydrology web page.

  19. Treatment Options for Primary Nocturnal Enuresis by Parents in a ...

    African Journals Online (AJOL)

    femi oloka

    common treatment option was waking up child at intervals during the night to void by 103 (45.2 ... patient/family education, simple behavioral ... nocturnal enuresis were employing in managing ..... Dental and Medical Sciences 2014;13:41 – 4.

  20. A Climatology of Nocturnal Low-Level Jets at Cabauw

    NARCIS (Netherlands)

    Baas, P.; Bosveld, F.C.; Baltink, H.K.; Holtslag, A.A.M.

    2009-01-01

    A climatology of nocturnal low-level jets (LLJs) is presented for the topographically flat measurement site at Cabauw, the Netherlands. LLJ characteristics are derived from a 7-yr half-hourly database of wind speed profiles, obtained from the 200-m mast and a wind profiler. Many LLJs at Cabauw

  1. The effect of lateral decubitus position on nocturnal intraocular pressure over a habitual 24-hour period in healthy adults.

    Directory of Open Access Journals (Sweden)

    Jie Hao

    Full Text Available PURPOSE: To investigate the effect of lateral decubitus position (LDP on nocturnal intraocular pressure (IOP and the effect of LDP on 24-hour habitual IOP pattern in healthy subjects. METHODS: Intraocular pressure was measured every 2-hours using an Accupen Applanation Tonometer (Accutome, USA. During the diurnal period (7:30 am, 9:30 am, 11:30 am, 1:30 pm, 3:30 pm, 5:30 pm, 7:30 pm, and 9:30 pm, IOP was measured in the sitting position under bright light (500-1000 lux after the subjects had been seated for 5 min. The nocturnal IOP was measured in the supine position, right LDP, and left LDP, with randomized sequences, under dim light (<10 lux at 11:30 pm, 1:30 am, 3:30 am, and 5:30 am. The subjects were awakened and maintained each position for 5 min before the measurement. The 24-hour habitual IOP patterns were obtained according to the nocturnal position (supine, right LDP and left LDP for either eye. P<0.05 was considered to be significant. RESULTS: Nineteen healthy subjects were included with a mean age of 51.3±5.8 years. During the nocturnal period, a significant IOP difference was found between the dependent eye (the eye on the lower side of LDP and the supine position, but not for all the nocturnal time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant, although the mean nocturnal IOP and the diurnal-nocturnal IOP change for the right and the left eye in the LDP pattern was slightly higher than that in the sitting-supine pattern. CONCLUSION: Significant nocturnal IOP differences existed between the dependent eye and the supine, but did not occur consistently for all time points. Over a 24-hour period, the effect of LDP on habitual IOP pattern was not statistically significant in healthy subjects.

  2. Thermal performance of an open thermosyphon using nanofluid for evacuated tubular high temperature air solar collector

    International Nuclear Information System (INIS)

    Liu, Zhen-Hua; Hu, Ren-Lin; Lu, Lin; Zhao, Feng; Xiao, Hong-shen

    2013-01-01

    Highlights: • A novel solar air collector with simplified CPC and open thermosyphon is designed and tested. • Simplified CPC has a much lower cost at the expense of slight efficiency loss. • Nanofluid effectively improves thermal performance of the above solar air collector. • Solar air collector with open thermosyphon is better than that with concentric tube. - Abstract: A novel evacuated tubular solar air collector integrated with simplified CPC (compound parabolic concentrator) and special open thermosyphon using water based CuO nanofluid as the working fluid is designed to provide air with high and moderate temperature. The experimental system has two linked panels and each panel includes an evacuated tube, a simplified CPC and an open thermosyphon. Outdoor experimental study has been carried out to investigate the actual solar collecting performance of the designed system. Experimental results show that air outlet temperature and system collecting efficiency of the solar air collector using nanofluid as the open thermosyphon’s working fluid are both higher than that using water. Its maximum air outlet temperature exceeds 170 °C at the air volume rate of 7.6 m 3 /h in winter, even though the experimental system consists of only two collecting panels. The solar collecting performance of the solar collector integrated with open thermosyphon is also compared with that integrated with common concentric tube. Experimental results show that the solar collector integrated with open thermosyphon has a much better collecting performance

  3. Mathematical modelling of NO emissions from high-temperature air combustion with nitrous oxide mechanism

    International Nuclear Information System (INIS)

    Yang, Weihong; Blasiak, Wlodzimierz

    2005-01-01

    A study of the mathematical modelling of NO formation and emissions in a gas-fired regenerative furnace with high-preheated air was performed. The model of NO formation via N 2 O-intermediate mechanism was proposed because of the lower flame temperature in this case. The reaction rates of this new model were calculated basing on the eddy-dissipation-concept. This model accompanied with thermal-NO, prompt-NO and NO reburning models were used to predict NO emissions and formations. The sensitivity of the furnace temperature and the oxygen availability on NO generation rate has been investigated. The predicted results were compared with experimental values. The results show that NO emission formed by N 2 O-intermediate mechanism is of outstanding importance during the high-temperature air combustion (HiTAC) condition. Furthermore, it shows that NO models with N 2 O-route model can give more reasonable profile of NO formation. Additionally, increasing excess air ratio leads to increasing of NO emission in the regenerative furnace. (author)

  4. The Effectiveness of Silodosin for Nocturnal Polyuria in Elderly Men With Benign Prostatic Hyperplasia: A Multicenter Study.

    Science.gov (United States)

    Kim, Young Won; Park, Jinsung; Chung, Hong; Kim, Hong-Wook; Kim, Hyung Joon; Jung, Jae Hung; Kim, Won Tae

    2015-09-01

    To investigate improvement in nocturia and nocturnal polyuria in nocturnal polyuria patients after silodosin administration by using a 3-day frequency volume chart. This was a prospective multicenter study. We enrolled nocturnal polyuria patients (nocturnal polyuria index [NPi]>0.33), aged ≥60 years, diagnosed with the 3-day frequency volume charts of patients with benign prostatic hyperplasia taking α-blockers. Of the 54 patients, 30 (55.6%) completed the study according to the study protocol (per-protocol group), and 24 dropped out (dropout group). Of the 24 patients in the dropout group, 5 withdrew consent due to side effects or lack of efficacy, 7 were lost to follow-up at 4 weeks, 8 were lost to follow-up at 12 weeks, and 4 dropped out due to failure to complete 3-day frequency volume charts at 12 weeks. In the per-protocol group, there was significant improvement in the International Prostate Symptom Score (IPSS), especially question numbers 1, 3, 4, 5, 6, 7, and the quality of life question (P=0.001, P=0.007, Psilodosin monotherapy exhibits good efficacy in improving nocturia and nocturnal polyuria; however, the mean NPi was still >0.33. Considering the high dropout rate of our study due to no implementation of 3-day frequency volume charts, prospective and large-scale studies are needed to confirm our results.

  5. Comparison of different statistical modelling approaches for deriving spatial air temperature patterns in an urban environment

    Science.gov (United States)

    Straub, Annette; Beck, Christoph; Breitner, Susanne; Cyrys, Josef; Geruschkat, Uta; Jacobeit, Jucundus; Kühlbach, Benjamin; Kusch, Thomas; Richter, Katja; Schneider, Alexandra; Umminger, Robin; Wolf, Kathrin

    2017-04-01

    Frequently spatial variations of air temperature of considerable magnitude occur within urban areas. They correspond to varying land use/land cover characteristics and vary with season, time of day and synoptic conditions. These temperature differences have an impact on human health and comfort directly by inducing thermal stress as well as indirectly by means of affecting air quality. Therefore, knowledge of the spatial patterns of air temperature in cities and the factors causing them is of great importance, e.g. for urban planners. A multitude of studies have shown statistical modelling to be a suitable tool for generating spatial air temperature patterns. This contribution presents a comparison of different statistical modelling approaches for deriving spatial air temperature patterns in the urban environment of Augsburg, Southern Germany. In Augsburg there exists a measurement network for air temperature and humidity currently comprising 48 stations in the city and its rural surroundings (corporately operated by the Institute of Epidemiology II, Helmholtz Zentrum München, German Research Center for Environmental Health and the Institute of Geography, University of Augsburg). Using different datasets for land surface characteristics (Open Street Map, Urban Atlas) area percentages of different types of land cover were calculated for quadratic buffer zones of different size (25, 50, 100, 250, 500 m) around the stations as well for source regions of advective air flow and used as predictors together with additional variables such as sky view factor, ground level and distance from the city centre. Multiple Linear Regression and Random Forest models for different situations taking into account season, time of day and weather condition were applied utilizing selected subsets of these predictors in order to model spatial distributions of mean hourly and daily air temperature deviations from a rural reference station. Furthermore, the different model setups were

  6. Early dinner reduces nocturnal gastric acidity.

    OpenAIRE

    Duroux, P; Bauerfeind, P; Emde, C; Koelz, H R; Blum, A L

    1989-01-01

    This study examines whether eating food at different times has differential effects on intragastric pH. Experiments were done in 23 healthy volunteers (12 men). Intragastric acidity was monitored by ambulatory 22 hour pH-metry. Composition of meals was standardised: breakfast and lunch at 7 am and 12 noon respectively, and dinner at 6 or 9 pm, in random order. The time of going to bed and getting up was also standardised. With early dinner nocturnal pH was higher, than with late dinner (pH me...

  7. Self-Reported Sleep Bruxism and Nocturnal Gastroesophageal Reflux Disease in Patients with Obstructive Sleep Apnea: Relationship to Gender and Ethnicity§

    Science.gov (United States)

    Hesselbacher, Sean; Subramanian, Shyam; Rao, Shweta; Casturi, Lata; Surani, Salim

    2014-01-01

    Study Objectives : Nocturnal bruxism is associated with gastroesophageal reflux disease (GERD), and GERD is strongly associated with obstructive sleep apnea (OSA). Gender and ethnic differences in the prevalence and clinical presentation of these often overlapping sleep disorders have not been well documented. Our aim was to examine the associations between, and the symptoms associated with, nocturnal GERD and sleep bruxism in patients with OSA, and to examine the influence of gender and ethnicity. Methods : A retrospective chart review was performed of patients diagnosed with OSA at an academic sleep center. The patients completed a sleep questionnaire prior to undergoing polysomnography. Patients with confirmed OSA were evaluated based on gender and ethnicity. Associations were determined between sleep bruxism and nocturnal GERD, and daytime sleepiness, insomnia, restless legs symptoms, and markers of OSA severity in each group. Results : In these patients with OSA, the prevalence of nocturnal GERD (35%) and sleep bruxism (26%) were higher than the general population. Sleep bruxism was more common in Caucasians than in African Americans or Hispanics; there was no gender difference. Nocturnal GERD was similar among all gender and ethnic groups. Bruxism was associated with nocturnal GERD in females, restless legs symptoms in all subjects and in males, sleepiness in African Americans, and insomnia in Hispanics. Nocturnal GERD was associated with sleepiness in males and African Americans, insomnia in females, and restless legs symptoms in females and in Caucasians. Conclusion : Patients with OSA commonly have comorbid sleep bruxism and nocturnal GERD, which may require separate treatment. Providers should be aware of differences in clinical presentation among different ethnic and gender groups. PMID:25352924

  8. Differential arousal regulation by prokineticin 2 signaling in the nocturnal mouse and the diurnal monkey.

    Science.gov (United States)

    Zhou, Qun-Yong; Burton, Katherine J; Neal, Matthew L; Qiao, Yu; Kanthasamy, Anumantha G; Sun, Yanjun; Xu, Xiangmin; Ma, Yuanye; Li, Xiaohan

    2016-08-18

    The temporal organization of activity/rest or sleep/wake rhythms for mammals is regulated by the interaction of light/dark cycle and circadian clocks. The neural and molecular mechanisms that confine the active phase to either day or night period for the diurnal and the nocturnal mammals are unclear. Here we report that prokineticin 2, previously shown as a circadian clock output molecule, is expressed in the intrinsically photosensitive retinal ganglion cells, and the expression of prokineticin 2 in the intrinsically photosensitive retinal ganglion cells is oscillatory in a clock-dependent manner. We further show that the prokineticin 2 signaling is required for the activity and arousal suppression by light in the mouse. Between the nocturnal mouse and the diurnal monkey, a signaling receptor for prokineticin 2 is differentially expressed in the retinorecipient suprachiasmatic nucleus and the superior colliculus, brain projection targets of the intrinsically photosensitive retinal ganglion cells. Blockade with a selective antagonist reveals the respectively inhibitory and stimulatory effect of prokineticin 2 signaling on the arousal levels for the nocturnal mouse and the diurnal monkey. Thus, the mammalian diurnality or nocturnality is likely determined by the differential signaling of prokineticin 2 from the intrinsically photosensitive retinal ganglion cells onto their retinorecipient brain targets.

  9. Long-Term Trend Analysis of Precipitation and Air Temperature for Kentucky, United States

    Directory of Open Access Journals (Sweden)

    Somsubhra Chattopadhyay

    2016-02-01

    Full Text Available Variation in quantities such as precipitation and temperature is often assessed by detecting and characterizing trends in available meteorological data. The objective of this study was to determine the long-term trends in annual precipitation and mean annual air temperature for the state of Kentucky. Non-parametric statistical tests were applied to homogenized and (as needed pre-whitened annual series of precipitation and mean air temperature during 1950–2010. Significant trends in annual precipitation were detected (both positive, averaging 4.1 mm/year for only two of the 60 precipitation-homogenous weather stations (Calloway and Carlisle counties in rural western Kentucky. Only three of the 42 temperature-homogenous stations demonstrated trends (all positive, averaging 0.01 °C/year in mean annual temperature: Calloway County, Allen County in southern-central Kentucky, and urbanized Jefferson County in northern-central Kentucky. In view of the locations of the stations demonstrating positive trends, similar work in adjacent states will be required to better understand the processes responsible for those trends and to properly place them in their larger context, if any.

  10. Air temperature and relative humidity in Dome Fuji Station buildings, East Antarctic ice sheet, in 2003

    Directory of Open Access Journals (Sweden)

    Takao Kameda

    2008-06-01

    Full Text Available In order to clarify the living condition in Dome Fuji Station in 2003, air temperature and relative humidity in the station were measured. Thermocouples with data logger and a ventilated psychrometer were used for the measurements. Average air temperature from February 11, 2003 to January 14, 2004 (missing period: July 19 to August 17 in the Dome Fuji Station buildings were as follows: Generator room 24.7℃, Dining room 23.5℃, Observation room 21.1℃, Dormitory room 18.2℃, Corridor 18.2℃, Food storage 8.2℃ and Old ice coring site -51.3℃. Average outside air temperature (1.5m height from the snow surface during the period was -54.4℃. A remarkable increase of outside air temperature (+30℃ at maximum due to a blocking high event was observed from October 31, 2003 to November 10, 2003 at Dome Fuji, during which increase of air temperature from 5 to 8°C in the station buildings was recorded. Snow on the station buildings was partly melted and some of the melted water penetrated into the station. This was the only time snow melted during the wintering over party's stay at the station. Average relative humidity in the station buildings obtained using a small humidifier was about 25%; the relative humidity without using the humidifier ranged from 9.0 to 22.9%.

  11. Pathophysiology of nocturnal enuresis

    DEFF Research Database (Denmark)

    Rittig, Søren; Kamperis, Konstantinos

    2015-01-01

    The perception of the pathogenesis of enuresis has undergone marked changes over the past 30 years from a psychiatric/psychological background to a more somatic model where nighttime urine production and bladder capacity are main components together with an arousal dysfunction that prevents...... that dysfunction of the intrinsic circadian regulation located in the suprachiasmatic nucleus results in dysfunction of one or more of the brainstem centers involved in AVP secretion, arousal function, bladder control, and blood pressure regulation. Furthermore, nocturnal enuresis has a strong genetic influence...... that in some families present as autosomal dominant inheritance with high degree of penetrance. Linkage to several chromosomal areas have been confirmed in such families although a specific causative enuresis gene has not yet been identified. In conclusion, our understanding of enuresis pathophysiology has...

  12. Role of City Texture in Urban Heat Islands at Nighttime

    Science.gov (United States)

    Sobstyl, J. M.; Emig, T.; Qomi, M. J. Abdolhosseini; Ulm, F.-J.; Pellenq, R. J.-M.

    2018-03-01

    An urban heat island (UHI) is a climate phenomenon that results in an increased air temperature in cities when compared to their rural surroundings. In this Letter, the dependence of an UHI on urban geometry is studied. Multiyear urban-rural temperature differences and building footprints data combined with a heat radiation scaling model are used to demonstrate for more than 50 cities worldwide that city texture—measured by a building distribution function and the sky view factor—explains city-to-city variations in nocturnal UHIs. Our results show a strong correlation between nocturnal UHIs and the city texture.

  13. Seeing in the dark: vision and visual behaviour in nocturnal bees and wasps.

    Science.gov (United States)

    Warrant, Eric J

    2008-06-01

    In response to the pressures of predation, parasitism and competition for limited resources, several groups of (mainly) tropical bees and wasps have independently evolved a nocturnal lifestyle. Like their day-active (diurnal) relatives, these insects possess apposition compound eyes, a relatively light-insensitive eye design that is best suited to vision in bright light. Despite this, nocturnal bees and wasps are able to forage at night, with many species capable of flying through a dark and complex forest between the nest and a foraging site, a behaviour that relies heavily on vision and is limited by light intensity. In the two best-studied species - the Central American sweat bee Megalopta genalis (Halictidae) and the Indian carpenter bee Xylocopa tranquebarica (Apidae) - learned visual landmarks are used to guide foraging and homing. Their apposition eyes, however, have only around 30 times greater optical sensitivity than the eyes of their closest diurnal relatives, a fact that is apparently inconsistent with their remarkable nocturnal visual abilities. Moreover, signals generated in the photoreceptors, even though amplified by a high transduction gain, are too noisy and slow to transmit significant amounts of information in dim light. How have nocturnal bees and wasps resolved these paradoxes? Even though this question remains to be answered conclusively, a mounting body of theoretical and experimental evidence suggests that the slow and noisy visual signals generated by the photoreceptors are spatially summed by second-order monopolar cells in the lamina, a process that could dramatically improve visual reliability for the coarser and slower features of the visual world at night.

  14. Thermodynamic and Turbulence Characteristics of the Southern Great Plains Nocturnal Boundary Layer Under Differing Turbulent Regimes

    Science.gov (United States)

    Bonin, Timothy A.; Blumberg, William G.; Klein, Petra M.; Chilson, Phillip B.

    2015-12-01

    The nocturnal stable boundary layer (SBL) can generally be classified into the weakly stable boundary layer (wSBL) and very stable boundary layer (vSBL). Within the wSBL, turbulence is relatively continuous, whereas in the vSBL, turbulence is intermittent and not well characterized. Differentiating characteristics of each type of SBL are still unknown. Herein, thermodynamic and kinematic data collected by a suite of instruments in north central Oklahoma in autumn 2012 are analyzed to better understand both SBL regimes and their differentiating characteristics. Many low-level jets were observed during the experiment, as it took place near a climatological maximum. A threshold wind speed, above which bulk shear-generated turbulence develops, is found to exist up to 300 m. The threshold wind speed must also be exceeded at lower heights (down to the surface) in order for strong turbulence to develop. Composite profiles, which are normalized using low-level jet scaling, of potential temperature, wind speed, vertical velocity variance, and the third-order moment of vertical velocity (overline{w'^3}) are produced for weak and moderate/strong turbulence regimes, which exhibit features of the vSBL and wSBL, respectively. Within the wSBL, turbulence is generated at the surface and transported upward. In the vSBL, values of vertical velocity variance are small throughout the entire boundary layer, likely due to the fact that a strong surface inversion typically forms after sunset. The temperature profile tends to be approximately isothermal in the lowest portions of the wSBL, and it did not substantially change over the night. Within both types of SBL, stability in the residual layer tends to increase as the night progresses. It is thought that this stability increase is due to differential warm air advection, which frequently occurs in the southern Great Plains when southerly low-level jets and a typical north-south temperature gradient are present. Differential radiative

  15. The Burden of COPD Morbidity Attributable to the Interaction between Ambient Air Pollution and Temperature in Chengdu, China

    Directory of Open Access Journals (Sweden)

    Hang Qiu

    2018-03-01

    Full Text Available Evidence on the burden of chronic obstructive pulmonary disease (COPD morbidity attributable to the interaction between ambient air pollution and temperature has been limited. This study aimed to examine the modification effect of temperature on the association of ambient air pollutants (including particulate matter (PM with aerodynamic diameter <10 μm (PM10 and <2.5 μm (PM2.5, nitrogen dioxide (NO2, sulfur dioxide (SO2, carbon monoxide (CO and ozone (O3 with risk of hospital admissions (HAs for COPD, as well as the associated morbidity burden in urban areas of Chengdu, China, from 2015 to 2016. Based on the generalized additive model (GAM with quasi-Poisson link, bivariate response surface model and stratification parametric model were developed to investigate the potential interactions between ambient air pollution and temperature on COPD HAs. We found consistent interactions between ambient air pollutants (PM2.5, PM10 and SO2 and low temperature on COPD HAs, demonstrated by the stronger associations between ambient air pollutants and COPD HAs at low temperatures than at moderate temperatures. Subgroup analyses showed that the elderly (≥80 years and males were more vulnerable to this interaction. The joint effect of PM and low temperature had the greatest impact on COPD morbidity burden. Using WHO air quality guidelines as reference concentration, about 17.30% (95% CI: 12.39%, 22.19% and 14.72% (95% CI: 10.38%, 19.06% of COPD HAs were attributable to PM2.5 and PM10 exposures on low temperature days, respectively. Our findings suggested that low temperature significantly enhanced the effects of PM and SO2 on COPD HAs in urban Chengdu, resulting in increased morbidity burden. This evidence has important implications for developing interventions to reduce the risk effect of COPD morbidity.

  16. Influence of deposits quantity and air temperature on 137Cs accumulation by the higher mushrooms

    International Nuclear Information System (INIS)

    Zarubina, N.E.

    2012-01-01

    Researches of the influence of weather conditions (amount of precipitation, air temperature) on 137 Cs content magnitude in fruit bodies of mushrooms: Boletus edulis Bull.: Fr., Suillus luteus (L.: Fr.) S.F.Gray, Xerocomus badius (Fr.) Kuhn. ex Gilb., Tricholoma flavovirens (Pers.: Fr.) Lund., Cantharellus cibarius Fr. at the territory of Chernobyl alienation zone and 'southern trace are performed. Correlation factors, determination factors between specific activity 137 Cs at mushrooms and quantity of deposits (mm) and the maximum temperature of air ( o C) are calculated. At calculations the decrease of the content of 137 Cs in mushrooms at the expense of disintegration of this isotope has been considered. As a result of researches the authentic dependence of specific activity 137 Cs in fruit bodies of the studied kinds of mushrooms from quantity of deposits and from air temperature has not been established.

  17. Salmeterol versus slow-release theophylline combined with ketotifen in nocturnal asthma: a multicentre trial. French Multicentre Study Group.

    Science.gov (United States)

    Muir, J F; Bertin, L; Georges, D

    1992-11-01

    We wished to assess the efficacy of inhaled salmeterol (SML; 50 micrograms b.i.d.) compared to a combination of slow-release theophylline and ketotifen p.o. (TK; T 300 mg+K 1 mg b.i.d.) for the treatment of nocturnal asthma. Ninety six patients with nocturnal asthma, (forced expiratory volume in one second (FEV1) 60-90% of predicted value, reversibility > or = 15%, at least two nocturnal awakenings per week) were eligible for a multicentre, double-blind, double-dummy cross-over study (14-day run-in, two successive 28-day treatment periods). Efficacy was assessed as success/failure, success being defined as the complete disappearance of nocturnal symptoms/awakening during the last week of each treatment period. There was a statistically significant difference between SML and TK for this criterion: 46% and 39% success with SML during periods I (first 28-day period) and II (following the cross-over), compared to only 15% and 26% with TK, respectively (p < 0.01). SML was also significantly better for the other criteria (lung function, rescue salbutamol intake during day and night). Side-effects were five times less frequent in SML-treated patients (p < 0.004). Efficacy and tolerance of SML were obviously far better than those of TK in patients with nocturnal asthma.

  18. Research and Development of Information and Communication Technology-based Home Blood Pressure Monitoring from Morning to Nocturnal Hypertension.

    Science.gov (United States)

    Kario, Kazuomi; Tomitani, Naoko; Matsumoto, Yuri; Hamasaki, Haruna; Okawara, Yukie; Kondo, Maiko; Nozue, Ryoko; Yamagata, Hiromi; Okura, Ayako; Hoshide, Satoshi

    2016-01-01

    Asians have specific characteristics of hypertension (HTN) and its relationship with cardiovascular disease. The morning surge in blood pressure (BP) in Asians is more extended, and the association slope between higher BP and the risk for cardiovascular events is steeper in this population than in whites. Thus, 24-hour BP control including at night and in the morning is especially important for Asian patients with HTN. There are 3 components of "perfect 24-hour BP control": the 24-hour BP level, adequate dipping of nocturnal BP (dipper type), and adequate BP variability such as the morning BP surge. The morning BP-guided approach using home BP monitoring (HBPM) is the first step toward perfect 24-hour BP control. After controlling morning HTN, nocturnal HTN is the second target. We have been developing HBPM that can measure nocturnal BP. First, we developed a semiautomatic HBPM device with the function of automatic fixed-interval BP measurement during sleep. In the J-HOP (Japan Morning Surge Home Blood Pressure) study, the largest nationwide home BP cohort, we successfully measured nocturnal home BP using this device with data memory, 3 times during sleep (2, 3, and 4 am), and found that nocturnal home BP is significantly correlated with organ damage independently of office and morning BP values. The second advance was the development of trigger nocturnal BP (TNP) monitoring with an added trigger function that initiates BP measurements when oxygen desaturation falls below a variable threshold continuously monitored by pulse oximetry. TNP can detect the specific nocturnal BP surges triggered by hypoxic episodes in patients with sleep apnea syndrome. We also added the lowest heart rate-trigger function to TNP to detect the "basal nocturnal BP," which is determined by the circulating volume and structural cardiovascular system without any increase in sympathetic tonus. This double TNP is a novel concept for evaluating the pathogenic pressor mechanism of nocturnal BP

  19. High temperature oxidation characteristics of developed Ni-Cr-W superalloys in air

    International Nuclear Information System (INIS)

    Suzuki, Tomio; Shindo, Masami

    1996-11-01

    For expanding utilization of the Ni-Cr-W superalloy, which has been developed as one of new high temperature structural materials used in the advanced High Temperature Gas-cooled Reactors (HTGRs), in various engineering fields including the structural material for heat utilization system, the oxidation behavior of this alloy in air as one of high oxidizing environments becomes one of key factors. The oxidation tests for the industrial scale heat of Ni-Cr-W superalloy with the optimized chemical composition and five kinds of experimental Ni-Cr-W alloys with different Cr/W ratio were carried out at high temperatures in the air compared with Hastelloy XR. The conclusions were obtained as follows. (1) The oxidation resistance of the industrial scale heat of Ni-Cr-W superalloy with the optimized chemical composition was superior to that of Hastelloy XR. (2) The most excellent oxidation resistance was obtained in an alloy with 19% Cr of the industrial scale heat of Ni-Cr-W superalloy. (author)

  20. Estimation of daily maximum and minimum air temperatures in urban landscapes using MODIS time series satellite data

    Science.gov (United States)

    Yoo, Cheolhee; Im, Jungho; Park, Seonyoung; Quackenbush, Lindi J.

    2018-03-01

    Urban air temperature is considered a significant variable for a variety of urban issues, and analyzing the spatial patterns of air temperature is important for urban planning and management. However, insufficient weather stations limit accurate spatial representation of temperature within a heterogeneous city. This study used a random forest machine learning approach to estimate daily maximum and minimum air temperatures (Tmax and Tmin) for two megacities with different climate characteristics: Los Angeles, USA, and Seoul, South Korea. This study used eight time-series land surface temperature (LST) data from Moderate Resolution Imaging Spectroradiometer (MODIS), with seven auxiliary variables: elevation, solar radiation, normalized difference vegetation index, latitude, longitude, aspect, and the percentage of impervious area. We found different relationships between the eight time-series LSTs with Tmax/Tmin for the two cities, and designed eight schemes with different input LST variables. The schemes were evaluated using the coefficient of determination (R2) and Root Mean Square Error (RMSE) from 10-fold cross-validation. The best schemes produced R2 of 0.850 and 0.777 and RMSE of 1.7 °C and 1.2 °C for Tmax and Tmin in Los Angeles, and R2 of 0.728 and 0.767 and RMSE of 1.1 °C and 1.2 °C for Tmax and Tmin in Seoul, respectively. LSTs obtained the day before were crucial for estimating daily urban air temperature. Estimated air temperature patterns showed that Tmax was highly dependent on the geographic factors (e.g., sea breeze, mountains) of the two cities, while Tmin showed marginally distinct temperature differences between built-up and vegetated areas in the two cities.

  1. Nocturnal polyuria and saluresis in renal allograft recipients.

    Science.gov (United States)

    Chan, M K; Varghese, Z; Fernando, O N; Moorhead, J F

    1980-01-01

    The evolution of nocturnal polyuria and saluresis in renal allograft recipients was studied by comparing the day to night (D:N) ratios of urine volume and sodium excretion in 15 patients who had undergone transplantation less than one year previously (recent-transplant group) with those in 11 patients who had undergone transplantation at least one year previously. Eleven patients with chronic renal failure and 12 normal subjects served as controls. Patients in the recent-transplant group had significantly lower D:N ratios of urine volume and sodium excretion than the patients who had undergone transplantation at least a year before, while the ratios in this last group did not differ significantly from those in the normal subjects. Nocturnal polyuria and saluresis gradually subsided in five patients studied for three months. Chronic renal failure and uraemic autonomic neuropathy were unlikely causes of the nocturia. The patients in the recent-transplant group had significantly lower D:N ratios of urine volume than the controls with chronic renal failure, and the mean Valsalva ratio in eight of them was not significantly different from that in the normal subjects. An undue sensitivity of renal allografts to postural influences was proposed. PMID:6986946

  2. Nocturnal, every-other-day, online haemodiafiltration: an effective therapeutic alternative.

    Science.gov (United States)

    Maduell, Francisco; Arias, Marta; Durán, Carlos E; Vera, Manel; Fontseré, Néstor; Azqueta, Manel; Rico, Nayra; Pérez, Nuria; Sentis, Alexis; Elena, Montserrat; Rodriguez, Néstor; Arcal, Carola; Bergadá, Eduardo; Cases, Aleix; Bedini, Jose Luis; Campistol, Josep M

    2012-04-01

    Longer and more frequent dialysis sessions have demonstrated excellent survival and clinical advantages, while online haemodiafiltration (OL-HDF) provides the most efficient form of dialysis treatment. The aim of this study was to evaluate the beneficial effects of a longer (nocturnal) and more frequent (every-other-day) dialysis schedule with OL-HDF at the same or the highest convective volume. This prospective, in-centre crossover study was carried out in 26 patients, 18 males and 8 females, 49.2±14 years old, on 4-5 h thrice-weekly post-dilution OL-HDF, switched to nocturnal every-other-day OL-HDF. Patient inclusion criteria consisted of stable patients with good vascular access and with good prospects for improved occupational, psychological and social rehabilitation. Patients were randomly assigned into two groups: Group A received the same convective volume as previously for 6 months followed by a higher convective volume for a further 6 months, while Group B received the same schedule in reverse order. Nocturnal every-other-day OL-HDF was well tolerated and 56% of patients who were working during the baseline period continued to work throughout the study with practically no absenteeism. The convective volume was 26.7±2 L at baseline, 27.5±2 with the unchanged volume and 42.9±4 L with the higher volume. eKt/V increased from 1.75±0.4 to 3.37±0.9. Bicarbonate, blood urea nitrogen (BUN) and creatinine values decreased, while phosphate levels fell markedly with a 90% reduction in phosphate binders. Blood pressure and left ventricular hypertrophy (LVH) improved and the use of anti-hypertensive drugs decreased. In both groups, BUN, creatinine and β2-microglobulin reduction ratios improved. Different removal patterns were observed for myoglobin, prolactin and α1-acid glycoprotein. Nocturnal every-other-day OL-HDF could be an excellent therapeutic alternative since good tolerance and occupational rehabilitation, marked improvement in dialysis dose

  3. Trend analysis of air temperature and precipitation time series over Greece: 1955-2010

    Science.gov (United States)

    Marougianni, G.; Melas, D.; Kioutsioukis, I.; Feidas, H.; Zanis, P.; Anandranistakis, E.

    2012-04-01

    In this study, a database of air temperature and precipitation time series from the network of Hellenic National Meteorological Service has been developed in the framework of the project GEOCLIMA, co-financed by the European Union and Greek national funds through the Operational Program "Competitiveness and Entrepreneurship" of the Research Funding Program COOPERATION 2009. Initially, a quality test was applied to the raw data and then missing observations have been imputed with a regularized, spatial-temporal expectation - maximization algorithm to complete the climatic record. Next, a quantile - matching algorithm was applied in order to verify the homogeneity of the data. The processed time series were used for the calculation of temporal annual and seasonal trends of air temperature and precipitation. Monthly maximum and minimum surface air temperature and precipitation means at all available stations in Greece were analyzed for temporal trends and spatial variation patterns for the longest common time period of homogenous data (1955 - 2010), applying the Mann-Kendall test. The majority of the examined stations showed a significant increase in the summer maximum and minimum temperatures; this could be possibly physically linked to the Etesian winds, because of the less frequent expansion of the low over the southeastern Mediterranean. Summer minimum temperatures have been increasing at a faster rate than that of summer maximum temperatures, reflecting an asymmetric change of extreme temperature distributions. Total annual precipitation has been significantly decreased at the stations located in western Greece, as well as in the southeast, while the remaining areas exhibit a non-significant negative trend. This reduction is very likely linked to the positive phase of the NAO that resulted in an increase in the frequency and persistence of anticyclones over the Mediterranean.

  4. Signatures of functional constraint at aye-aye opsin genes: the potential of adaptive color vision in a nocturnal primate.

    Science.gov (United States)

    Perry, George H; Martin, Robert D; Verrelli, Brian C

    2007-09-01

    While color vision perception is thought to be adaptively correlated with foraging efficiency for diurnal mammals, those that forage exclusively at night may not need color vision nor have the capacity for it. Indeed, although the basic condition for mammals is dichromacy, diverse nocturnal mammals have only monochromatic vision, resulting from functional loss of the short-wavelength sensitive opsin gene. However, many nocturnal primates maintain intact two opsin genes and thus have dichromatic capacity. The evolutionary significance of this surprising observation has not yet been elucidated. We used a molecular population genetics approach to test evolutionary hypotheses for the two intact opsin genes of the fully nocturnal aye-aye (Daubentonia madagascariensis), a highly unusual and endangered Madagascar primate. No evidence of gene degradation in either opsin gene was observed for any of 8 aye-aye individuals examined. Furthermore, levels of nucleotide diversity for opsin gene functional sites were lower than those for 15 neutrally evolving intergenic regions (>25 kb in total), which is consistent with a history of purifying selection on aye-aye opsin genes. The most likely explanation for these findings is that dichromacy is advantageous for aye-ayes despite their nocturnal activity pattern. We speculate that dichromatic nocturnal primates may be able to perceive color while foraging under moonlight conditions, and suggest that behavioral and ecological comparisons among dichromatic and monochromatic nocturnal primates will help to elucidate the specific activities for which color vision perception is advantageous.

  5. Body position and late postoperative nocturnal hypoxaemia

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Stausholm, K; Edvardsen, L

    1997-01-01

    Thirteen patients were monitored for nocturnal body position (supine vs. side) and arterial oxygen saturation pre-operatively and on the second postoperative night after major abdominal surgery. The number of positional changes were significantly decreased after operation (p ... position than on the side (p movements....... towards more time spent in the supine position (p = 0.1). Individual mean arterial oxygen saturation decreased postoperatively (p positions (p = 0.9). Pre-operatively, episodic desaturations were significantly more frequent in the supine...

  6. NEDO project reports. High performance industrial furnace development project - High temperature air combustion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-21

    For the purpose of reducing energy consumption, a NEDO project 'Developmental research on high efficiency industrial furnaces' was carried out from FY 1993 to FY 1999 by The Japan Industrial Furnaces Manufacturers Association, and the paper outlined the details of the project. Industrial furnaces handled in this R and D can bring 30% reduction of the energy consumption and approximately 50% NOx reduction, and were given the 9th Nikkei global environmental technology prize. In the study of combustion phenomena of high temperature air combustion, the paper arranged characteristics of flame, the base of gaseous fuel flame, the base of liquid fuel flame, the base of solid fuel flame, etc. Concerning high temperature air combustion models for simulation, fluid dynamics and heat transfer models, and reaction and NOx models, etc. As to impacts of high temperature air combustion on performance of industrial furnaces, energy conservation, lowering of pollution, etc. In relation to a guide for the design of high efficiency industrial furnaces, flow charts, conceptual design, evaluation method for heat balance and efficiency using charts, combustion control system, applicability of high efficiency industrial furnaces, etc. (NEDO)

  7. NEDO project reports. High performance industrial furnace development project - High temperature air combustion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-21

    For the purpose of reducing energy consumption, a NEDO project 'Developmental research on high efficiency industrial furnaces' was carried out from FY 1993 to FY 1999 by The Japan Industrial Furnaces Manufacturers Association, and the paper outlined the details of the project. Industrial furnaces handled in this R and D can bring 30% reduction of the energy consumption and approximately 50% NOx reduction, and were given the 9th Nikkei global environmental technology prize. In the study of combustion phenomena of high temperature air combustion, the paper arranged characteristics of flame, the base of gaseous fuel flame, the base of liquid fuel flame, the base of solid fuel flame, etc. Concerning high temperature air combustion models for simulation, fluid dynamics and heat transfer models, and reaction and NOx models, etc. As to impacts of high temperature air combustion on performance of industrial furnaces, energy conservation, lowering of pollution, etc. In relation to a guide for the design of high efficiency industrial furnaces, flow charts, conceptual design, evaluation method for heat balance and efficiency using charts, combustion control system, applicability of high efficiency industrial furnaces, etc. (NEDO)

  8. Multiplatform inversion of the 2013 Rim Fire smoke emissions using regional-scale modeling: important nocturnal fire activity, air quality, and climate impacts

    Science.gov (United States)

    Saide, P. E.; Peterson, D. A.; da Silva, A. M., Jr.; Ziemba, L. D.; Anderson, B.; Diskin, G. S.; Sachse, G. W.; Hair, J. W.; Butler, C. F.; Fenn, M. A.; Jimenez, J. L.; Campuzano Jost, P.; Dibb, J. E.; Yokelson, R. J.; Toon, B.; Carmichael, G. R.

    2014-12-01

    Large wildfire events are increasingly recognized for their adverse effects on air quality and visibility, thus providing motivation for improving smoke emission estimates. The Rim Fire, one of the largest events in California's history, produced a large smoke plume that was sampled by the Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) DC-8 aircraft with a full suite of in-situ and remote sensing measurements on 26-27 August 2013. We developed an inversion methodology which uses the WRF-Chem modeling system to constrain hourly fire emissions, using as initial estimates the NASA Quick Fire Emissions Dataset (QFED). This method differs from the commonly performed top-down estimates that constrain daily (or longer time scale) emissions. The inversion method is able to simultaneously improve the model fit to various SEAC4RS airborne measurements (e.g., organic aerosol, carbon monoxide (CO), aerosol extinction), ground based measurements (e.g., AERONET aerosol optical depth (AOD), CO), and satellite data (MODIS AOD) by modifying fire emissions and utilizing the information content of all these measurements. Preliminary results show that constrained emissions for a 6 day period following the largest fire growth are a factor 2-4 higher than the initial top-down estimates. Moreover, there is a tendency to increase nocturnal emissions by factors sometimes larger than 20, indicating that vigorous fire activity continued during the night. This deviation from a typical diurnal cycle is confirmed using geostationary satellite data. The constrained emissions also have a larger day-to-day variability than the initial emissions and correlate better to daily area burned estimates as observed by airborne infrared measurements (NIROPS). Experiments with the assimilation system show that performing the inversion using only satellite AOD data produces much smaller correction factors than when using all available data

  9. The Effect of Solar Reflective Cover on Soak Air Temperature and Thermal Comfort of Car Parked under the Sun

    Directory of Open Access Journals (Sweden)

    Lahimer A.A.

    2017-01-01

    Full Text Available Parking a vehicle under the sun for a short period of time can rapidly increase the interior air cabin temperature no matter in clear sky days or even in partially cloudy days. These circumstances can be anxieties to car occupants upon entry. The aim of this paper is to evaluate experimentally the effect of solar reflective cover (SRC on vehicle air temperature and cabin thermal comfort. Experimental measurements of parked cars were conducted in UKM, Bangi city, Malaysia (latitude of 2.9° N and longitude of 101.78° E under partially cloudy day where average ambient temperature is 33°C. The experimental measurements cover the following cases: case (I: car with/ without SRC (at different measurement time; Case (II: using two identical cars concurrently (SRC versus baseline; Case (III: using two identical cars concurrently (solar reflective film (SRF versus baseline and Case (IV: using two identical cars concurrently (SRF versus SRC. Experimental results dedicated to case (I revealed that the maximum cabin air temperature with SRC (39.6°C is significantly lower than that of baseline case (57.3°C. This leads to temperature reduction improvement of 31% and the difference between the cabin and the ambient air temperature was minimized by approximately 73%. In addition, the results revealed that the air temperature at breath level of car with SRC dropped to comfort temperature (27°C after 7 min while baseline car reached comfort temperature after 14 min. Results of the other cases are discussed inside the paper. Overall, it is learned that SRC is found superior as an efficient thermal insulation system limits solar radiation transmission into the cabin through the glass; keeps cabin air temperature close to the ambient temperature; and provide acceptable thermal environment to the occupants as they settle into their parked car.

  10. The Effect of Solar Reflective Cover on Soak Air Temperature and Thermal Comfort of Car Parked under the Sun

    Science.gov (United States)

    Lahimer, A. A.; Alghoul, M. A.; Sopian, K.; Khrit, N. G.

    2017-11-01

    Parking a vehicle under the sun for a short period of time can rapidly increase the interior air cabin temperature no matter in clear sky days or even in partially cloudy days. These circumstances can be anxieties to car occupants upon entry. The aim of this paper is to evaluate experimentally the effect of solar reflective cover (SRC) on vehicle air temperature and cabin thermal comfort. Experimental measurements of parked cars were conducted in UKM, Bangi city, Malaysia (latitude of 2.9° N and longitude of 101.78° E) under partially cloudy day where average ambient temperature is 33°C. The experimental measurements cover the following cases: case (I): car with/ without SRC (at different measurement time); Case (II): using two identical cars concurrently (SRC versus baseline); Case (III): using two identical cars concurrently (solar reflective film (SRF) versus baseline) and Case (IV): using two identical cars concurrently (SRF versus SRC). Experimental results dedicated to case (I) revealed that the maximum cabin air temperature with SRC (39.6°C) is significantly lower than that of baseline case (57.3°C). This leads to temperature reduction improvement of 31% and the difference between the cabin and the ambient air temperature was minimized by approximately 73%. In addition, the results revealed that the air temperature at breath level of car with SRC dropped to comfort temperature (27°C) after 7 min while baseline car reached comfort temperature after 14 min. Results of the other cases are discussed inside the paper. Overall, it is learned that SRC is found superior as an efficient thermal insulation system limits solar radiation transmission into the cabin through the glass; keeps cabin air temperature close to the ambient temperature; and provide acceptable thermal environment to the occupants as they settle into their parked car.

  11. Depression of nocturnal pineal serotonin N-acetyltransferase activity in castrate male rats

    International Nuclear Information System (INIS)

    Rudeen, P.K.; Reiter, R.J.; Texas Univ., San Antonio

    1980-01-01

    Pineal serotonin N-acetyltransferase (NAT) activity was examined in intact rats, castrated rats, and in rats that had been castrated and had received testosterone proprionate. Castration resulted in significantly depressing nocturnal levels of pineal NAT (p<0.05) when compared to enzyme activity in intact rats. Testosterone proprionate administration restored plasma LH levels to normal values in castrate rats but did not induce nocturnal pineal enzyme activity to levels seen in the pineal glands of intact rats. The data substantiate the existence of a feedback control of pineal biosynthetic activity by the hypophyseal-gonadal system, but the identity of the hormone(s) responsible for regulation of pineal NAT activity is not known. (author)

  12. Air breathing in the Arctic: influence of temperature, hypoxia, activity and restricted air access on respiratory physiology of the Alaska blackfish Dallia pectoralis.

    Science.gov (United States)

    Lefevre, Sjannie; Damsgaard, Christian; Pascale, Desirae R; Nilsson, Göran E; Stecyk, Jonathan A W

    2014-12-15

    The Alaska blackfish (Dallia pectoralis) is an air-breathing fish native to Alaska and the Bering Sea islands, where it inhabits lakes that are ice-covered in the winter, but enters warm and hypoxic waters in the summer to forage and reproduce. To understand the respiratory physiology of this species under these conditions and the selective pressures that maintain the ability to breathe air, we acclimated fish to 5°C and 15°C and used respirometry to measure: standard oxygen uptake (Ṁ(O₂)) in normoxia (19.8 kPa P(O₂)) and hypoxia (2.5 kPa), with and without access to air; partitioning of standard Ṁ(O₂) in normoxia and hypoxia; maximum Ṁ(O₂) and partitioning after exercise; and critical oxygen tension (P(crit)). Additionally, the effects of temperature acclimation on haematocrit, haemoglobin oxygen affinity and gill morphology were assessed. Standard Ṁ(O₂) was higher, but air breathing was not increased, at 15°C or after exercise at both temperatures. Fish acclimated to 5°C or 15°C increased air breathing to compensate and fully maintain standard Ṁ(O₂) in hypoxia. Fish were able to maintain Ṁ(O₂) through aquatic respiration when air was denied in normoxia, but when air was denied in hypoxia, standard Ṁ(O₂) was reduced by ∼30-50%. P(crit) was relatively high (5 kPa) and there were no differences in P(crit), gill morphology, haematocrit or haemoglobin oxygen affinity at the two temperatures. Therefore, Alaska blackfish depends on air breathing in hypoxia and additional mechanisms must thus be utilised to survive hypoxic submergence during the winter, such as hypoxia-induced enhancement in the capacities for carrying and binding blood oxygen, behavioural avoidance of hypoxia and suppression of metabolic rate. © 2014. Published by The Company of Biologists Ltd.

  13. Analysis of Humid Air Turbine Cycle with Low- or Medium-Temperature Solar Energy

    International Nuclear Information System (INIS)

    Hongbin Zhao, H.; Yue, P.; Cao, L.

    2009-01-01

    A new humid air turbine cycle that uses low- or medium-temperature solar energy as assistant heat source was proposed for increasing the mass flow rate of humid air. Based on the combination of the first and second laws of thermodynamics, this paper described and compared the performances of the conventional and the solar HAT cycles. The effects of some parameters such as pressure ratio, turbine inlet temperature (TIT), and solar collector efficiency on humidity, specific work, cycle's exergy efficiency, and solar energy to electricity efficiency were discussed in detail. Compared with the conventional HAT cycle, because of the increased humid air mass flow rate in the new system, the humidity and the specific work of the new system were increased. Meanwhile, the solar energy to electricity efficiency was greatly improved. Additionally, the exergy losses of components in the system under the given conditions were also studied and analyzed.

  14. Choking at Night: A Case of Opercular Nocturnal Frontal Lobe Epilepsy

    Directory of Open Access Journals (Sweden)

    Geetanjali Rathore

    2013-01-01

    Full Text Available Frontal lobe seizures have a tendency to occur in sleep and in most cases occur exclusively insleep; these individuals are said to have nocturnal frontal lobe (NFLE. NFLE can be difficult to distinguish clinically from various other sleep disorders, particularly parasomnias, which also present with paroxysmal motor activity in sleep. Interictal and ictal EEG findings are frequently unremarkable or nonspecific in both parasomnias and NFLE making the diagnosis even more difficult. Nocturnal epilepsy should be suspected in patients with paroxysmal events at night characterized by high frequency, repetition, extrapyramidal features, and marked stereotypy of attacks. Here we present a 13-year-old female who was extensively worked up for choking episodes at night. On repeat video EEG she was found to have frontal opercular seizures. Once on Carbamazepine, her seizures completely resolved.

  15. Response of surface air temperature to small-scale land clearing across latitudes

    International Nuclear Information System (INIS)

    Zhang, Mi; Wang, Wei; Lee, Xuhui; Yu, Guirui; Wang, Huimin; Han, Shijie; Yan, Junhua; Zhang, Yiping; Li, Yide; Ohta, Takeshi; Hirano, Takashi; Kim, Joon; Yoshifuji, Natsuko

    2014-01-01

    Climate models simulating continental scale deforestation suggest a warming effect of land clearing on the surface air temperature in the tropical zone and a cooling effect in the boreal zone due to different control of biogeochemical and biophysical processes. Ongoing land-use/cover changes mostly occur at local scales (hectares), and it is not clear whether the local-scale deforestation will generate temperature patterns consistent with the climate model results. Here we paired 40 and 12 flux sites with nearby weather stations in North and South America and in Eastern Asia, respectively, and quantified the temperature difference between these paired sites. Our goal was to investigate the response of the surface air temperature to local-scale (hectares) land clearing across latitudes using the surface weather stations as proxies for localized land clearing. The results show that north of 10°N, the annual mean temperature difference (open land minus forest) decreases with increasing latitude, but the temperature difference shrinks with latitude at a faster rate in the Americas [−0.079 (±0.010) °C per degree] than in Asia [−0.046 (±0.011) °C per degree]. Regression of the combined data suggests a transitional latitude of about 35.5°N that demarks deforestation warming to the south and cooling to the north. The warming in latitudes south of 35°N is associated with increase in the daily maximum temperature, with little change in the daily minimum temperature while the reverse is true in the boreal latitudes. (paper)

  16. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  17. Effect of air preheat temperature on the MILD combustion of syngas

    International Nuclear Information System (INIS)

    Huang, Mingming; Zhang, Zhedian; Shao, Weiwei; Xiong, Yan; Liu, Yan; Lei, Fulin; Xiao, Yunhan

    2014-01-01

    Highlights: • MILD combustion is achieved with reaction zone covering the entire combustion chamber. • Critical equivalence ratio for the occurrence of MILD combustion is identified. • MILD regime can be established for syngas fuel under air preheating conditions. - Abstract: The effect of air preheat temperature on MILD (Moderate or Intense Low-oxygen Dilution) combustion of coal-derived syngas was examined in parallel jet forward flow combustor. The results were presented on flow field using numerical simulations and on global flame signatures, OH ∗ radicals distribution and exhaust emissions using experiments. The discrete and high speed air/fuel injections into the combustor is necessary for the establishment of MILD conditions, because they cause strong gas recirculation and form large mixing region between the air and fuel jets. The critical equivalence ratio above which MILD combustion occurred was identified. The MILD regime was established for syngas fuel under air preheating conditions with lean operational limit and suppressed NO x and CO emissions. In the MILD combustion regime, the air preheating resulted in higher NO x but lower CO emissions, while the increase of equivalence ratio led to the increase of NO x and the decrease of CO emissions

  18. An Integrated Approach to Estimate Instantaneous Near-Surface Air Temperature and Sensible Heat Flux Fields during the SEMAPHORE Experiment.

    Science.gov (United States)

    Bourras, Denis; Eymard, Laurence; Liu, W. Timothy; Dupuis, Hélène

    2002-03-01

    A new technique was developed to retrieve near-surface instantaneous air temperatures and turbulent sensible heat fluxes using satellite data during the Structure des Echanges Mer-Atmosphere, Proprietes des Heterogeneites Oceaniques: Recherche Experimentale (SEMAPHORE) experiment, which was conducted in 1993 under mainly anticyclonic conditions. The method is based on a regional, horizontal atmospheric temperature advection model whose inputs are wind vectors, sea surface temperature fields, air temperatures around the region under study, and several constants derived from in situ measurements. The intrinsic rms error of the method is 0.7°C in terms of air temperature and 9 W m2 for the fluxes, both at 0.16° × 0.16° and 1.125° × 1.125° resolution. The retrieved air temperature and flux horizontal structures are in good agreement with fields from two operational general circulation models. The application to SEMAPHORE data involves the First European Remote Sensing Satellite (ERS-1) wind fields, Advanced Very High Resolution Radiometer (AVHRR) SST fields, and European Centre for Medium-Range Weather Forecasts (ECMWF) air temperature boundary conditions. The rms errors obtained by comparing the estimations with research vessel measurements are 0.3°C and 5 W m2.

  19. Temperature, air pollution, and mortality from myocardial infarction in São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Sharovsky R.

    2004-01-01

    Full Text Available An increase in daily mortality from myocardial infarction has been observed in association with meteorological factors and air pollution in several cities in the world, mainly in the northern hemisphere. The objective of the present study was to analyze the independent effects of environmental variables on daily counts of death from myocardial infarction in a subtropical region in South America. We used the robust Poisson regression to investigate associations between weather (temperature, humidity and barometric pressure, air pollution (sulfur dioxide, carbon monoxide, and inhalable particulate, and the daily death counts attributed to myocardial infarction in the city of São Paulo in Brazil, where 12,007 fatal events were observed from 1996 to 1998. The model was adjusted in a linear fashion for relative humidity and day-of-week, while nonparametric smoothing factors were used for seasonal trend and temperature. We found a significant association of daily temperature with deaths due to myocardial infarction (P < 0.001, with the lowest mortality being observed at temperatures between 21.6 and 22.6ºC. Relative humidity appeared to exert a protective effect. Sulfur dioxide concentrations correlated linearly with myocardial infarction deaths, increasing the number of fatal events by 3.4% (relative risk of 1.03; 95% confidence interval = 1.02-1.05 for each 10 µg/m³ increase. In conclusion, this study provides evidence of important associations between daily temperature and air pollution and mortality from myocardial infarction in a subtropical region, even after a comprehensive control for confounding factors.

  20. Influence of deposits quantity and air temperature on 137Cs accumulation by the higher mushrooms

    Directory of Open Access Journals (Sweden)

    N. E. Zarubina

    2012-12-01

    Full Text Available Researches of the influence of weather conditions (amount of precipitation, air temperature on 137Cs content’s magnitude in fruit bodies of mushrooms: Boletus edulis Bull.: Fr., Suillus luteus (L.: Fr. S.F.Gray, Xerocomus badius (Fr. Kuhn. ex Gilb., Tricholoma flavovirens (Pers.: Fr. Lund., Cantharellus cibarius Fr. at the territory of Chernobyl alienation zone and «southern trace» are performed. Correlation factors, determination factors between specific activity 137Cs at mushrooms and quantity of deposits (mm and the maximum temperature of air (0С are calculated. At calculations the decrease of the content of 137Cs in mushrooms at the expense of disintegration of this isotope has been considered. As a result of researches the authentic dependence of specific activity 137Cs in fruit bodies of the studied kinds of mushrooms from quantity of deposits and from air temperature has not been established.

  1. Comparison of Simulated Stem Temperatures and Observed Air Temperatures with Observed Stem Growth in Forest Openings

    Science.gov (United States)

    Brian E. Potter; Terry Strong

    2002-01-01

    Phenology, the study of how plant or animal developmental stages relate to the organism's surrounding climate, is a well established discipline with roots dating back more than 2000 years (Hopp and Blair, 1973). For example, correlations are often noted between budbreak or first blossom and integrated air temperature (commonly referred to as heat sums.) The...

  2. A review of reaction rates in high temperature air

    Science.gov (United States)

    Park, Chul

    1989-01-01

    The existing experimental data on the rate coefficients for the chemical reactions in nonequilibrium high temperature air are reviewed and collated, and a selected set of such values is recommended for use in hypersonic flow calculations. For the reactions of neutral species, the recommended values are chosen from the experimental data that existed mostly prior to 1970, and are slightly different from those used previously. For the reactions involving ions, the recommended rate coefficients are newly chosen from the experimental data obtained more recently. The reacting environment is assumed to lack thermal equilibrium, and the rate coefficients are expressed as a function of the controlling temperature, incorporating the recent multitemperature reaction concept.

  3. A dynamic model and an experimental study for the internal air and soil temperatures in an innovative greenhouse

    International Nuclear Information System (INIS)

    Joudi, Khalid A.; Farhan, Ammar A.

    2015-01-01

    Highlights: • Simulation model for internal Greenhouse temperature including soil reflectance. • Greenhouse soil heat exchange affects internal temperature by approximately 12%. • Solar air heaters as greenhouse roof maintain better internal temperature year round. - Abstract: An innovative greenhouse which integrates a conventional greenhouse with roof mounted solar air heaters is used in this investigation. This design reduces the solar radiation incoming to the greenhouse in summer which reduced the load and cost of greenhouse cooling and provides a means of solar heating. Experimental measurements of the internal air and internal soil sub-layer temperatures in the greenhouse, without crops, were performed in Baghdad University, Baghdad, Iraq (33.3 °N, 44.4 °E). Measurements were recorded for clear and partly cloudy winter days. A dynamic model was developed to predict the all internal temperatures of the greenhouse. This model includes soil surface heat exchange with the greenhouse air which was found to give a more accurate prediction of the internal temperatures. Soil surface heat exchange has a positive contribution to the internal environment. The input parameters of the model were the measured meteorological conditions and the thermo-physical properties of the greenhouse components which include the cover, inside air, and soil. Comparisons between the predicted and measured results show good agreement. Also, results show that soil sub-layers inside the greenhouse at 50 cm depth are the best place for heat storage elements. The integrated system rendered maximum differences between ambient and internal air temperatures of 16 °C in February and 10 °C in June without operating any heating or cooling system

  4. The effect of compressed air massage on skin blood flow and temperature.

    Science.gov (United States)

    Mars, Maurice; Maharaj, Sunil S; Tufts, Mark

    2005-01-01

    Compressed air massage is a new treatment modality that uses air under pressure to massage skin and muscle. It is claimed to improve skin blood flow but this has not been verified. Several pilot studies were undertaken to determine the effects of compressed air massage on skin blood flow and temperature. Skin blood flow (SBF), measured using laser Doppler fluxmetry and skin temperature was recorded under several different situations: (i) treatment, at 1 Bar pressure using a single-hole (5-mm) applicator head, for 1 min at each of several sites on the right and left lower legs, with SBF measured on the dorsum of the left foot; (ii) at the same treatment pressure, SBF was measured over the left tibialis anterior when treatment was performed at different distances from the probe; (iii) SBF and skin temperature of the lower leg were measured with treatment at 0 or 1 Bar for 45 min, using two different applicator heads; (iv) SBF was measured on the dorsum of the foot of 10 subjects with treatment for 1 min at 0, 0.5, 1, 1.5 and 2 Bar using three different applicator heads. (i) SBF of the left foot was not altered by treatment of the right leg or chest, but was significantly increased during treatment of the left sole and first web, p Compressed air massage causes an immediate increase in SBF, and an immediate fall in SBF when treatment is stopped. The effect appears to be locally and not centrally mediated and is related to the pressure used. Treatment cools the skin for at least 15 min after a 45-min treatment.

  5. Smart Control of Air Climatization System in Function on the Values of Mean Local Radiant Temperature

    Directory of Open Access Journals (Sweden)

    Giuseppe Cannistraro

    2015-08-01

    Full Text Available The hygrothermal comfort indoor conditions are defined as: those environmental conditions in which an individual exposed, expresses a state of satisfaction. These conditions cannot always be achieved anywhere in an optimal way and economically; in some cases they can be obtained only in work environments specific areas. This could be explained because of air conditioning systems designing is generally performed both on the basis of the fundamental parameters’ average values, such as temperature, velocity and relative humidity (Ta, va e φa and derived parameters such as operating temperature and mean radiant one (Top eTmr. However, in some specific cases - large open-spaces or in case of radiating surfaces - the descriptors defining indoor comfort conditions, based on average values, do not provide the optimum values required during the air conditioning systems design phase. This is largely due to the variability of real environmental parameters values compared to the average ones taken as input in the calculation. The results obtained in previous scientific papers on the thermal comfort have been the driving element of this work. It offers a simple, original and clever way of thinking about the new domotic systems for air conditioning, based on the “local mean radiant temperature.” This is a very important parameter when one wants to analyze comfort in environments characterized by the presence of radiating surfaces, as will be seen hereinafter. In order to take into account the effects of radiative exchanges in the open-space workplace, where any occupant may find themselves in different temperature and humidity conditions, this paper proposes an action on the domotic climate control, with ducts and vents air distribution placed in different zones. Comparisons were performed between the parameters values representing the punctual thermal comfort, with the Predicted Mean Vote PMV, in an environment marked by radiating surfaces (i

  6. Evaluation of MODIS Land Surface Temperature with In Situ Snow Surface Temperature from CREST-SAFE

    Science.gov (United States)

    Perez Diaz, C. L.; Lakhankar, T.; Romanov, P.; Munoz, J.; Khanbilvardi, R.; Yu, Y.

    2016-12-01

    This paper presents the procedure and results of a temperature-based validation approach for the Moderate Resolution Imaging Spectroradiometer (MODIS) Land Surface Temperature (LST) product provided by the National Aeronautics and Space Administration (NASA) Terra and Aqua Earth Observing System satellites using in situ LST observations recorded at the Cooperative Remote Sensing Science and Technology Center - Snow Analysis and Field Experiment (CREST-SAFE) during the years of 2013 (January-April) and 2014 (February-April). A total of 314 day and night clear-sky thermal images, acquired by the Terra and Aqua satellites, were processed and compared to ground-truth data from CREST-SAFE with a frequency of one measurement every 3 min. Additionally, this investigation incorporated supplementary analyses using meteorological CREST-SAFE in situ variables (i.e. wind speed, cloud cover, incoming solar radiation) to study their effects on in situ snow surface temperature (T-skin) and T-air. Furthermore, a single pixel (1km2) and several spatially averaged pixels were used for satellite LST validation by increasing the MODIS window size to 5x5, 9x9, and 25x25 windows for comparison. Several trends in the MODIS LST data were observed, including the underestimation of daytime values and nighttime values. Results indicate that, although all the data sets (Terra and Aqua, diurnal and nocturnal) showed high correlation with ground measurements, day values yielded slightly higher accuracy ( 1°C), both suggesting that MODIS LST retrievals are reliable for similar land cover classes and atmospheric conditions. Results from the CREST-SAFE in situ variables' analyses indicate that T-air is commonly higher than T-skin, and that a lack of cloud cover results in: lower T-skin and higher T-air minus T-skin difference (T-diff). Additionally, the study revealed that T-diff is inversely proportional to cloud cover, wind speed, and incoming solar radiation. Increasing the MODIS window size

  7. Heat Exchange with Air and Temperature Profile of a Moving Oversize Tire

    Science.gov (United States)

    Grinchuk, P. S.; Fisenko, S. P.

    2016-11-01

    A one-dimensional mathematical model of heat transfer in a tire with account for the deformation energy dissipation and heat exchange of a moving tire with air has been developed. The mean temperature profiles are calculated and transition to a stationary thermal regime is considered. The influence of the rate of energy dissipation and of effective thermal conductivity of rubber on the temperature field is investigated quantitatively.

  8. The intraseasonal variability of winter semester surface air temperature in Antarctica

    Directory of Open Access Journals (Sweden)

    Lejiang Yu

    2011-02-01

    Full Text Available This study investigates systematically the intraseasonal variability of surface air temperature over Antarctica by applying empirical orthogonal function (EOF analysis to the National Centers for Environmental Prediction, US Department of Energy, Reanalysis 2 data set for the period of 1979 through 2007. The results reveal the existence of two major intraseasonal oscillations of surface temperature with periods of 26–30 days and 14 days during the Antarctic winter season in the region south of 60°S. The first EOF mode shows a nearly uniform spatial pattern in Antarctica and the Southern Ocean associated with the Antarctic Oscillation. The mode-1 intraseasonal variability of the surface temperature leads that of upper atmosphere by one day with the largest correlation at 300-hPa level geopotential heights. The intraseasonal variability of the mode-1 EOF is closely related to the variations of surface net longwave radiation the total cloud cover over Antarctica. The other major EOF modes reveal the existence of eastward propagating phases over the Southern Ocean and marginal region in Antarctica. The leading two propagating modes respond to Pacific–South American modes. Meridional winds induced by the wave train from the tropics have a direct influence on the surface air temperature over the Southern Ocean and the marginal region of the Antarctic continent.

  9. A transition to white LED increases ecological impacts of nocturnal illumination on aquatic primary producers in a lowland agricultural drainage ditch.

    Science.gov (United States)

    Grubisic, Maja; van Grunsven, Roy H A; Manfrin, Alessandro; Monaghan, Michael T; Hölker, Franz

    2018-05-14

    The increasing use of artificial light at night (ALAN) has led to exposure of freshwater ecosystems to light pollution worldwide. Simultaneously, the spectral composition of nocturnal illumination is changing, following the current shift in outdoor lighting technologies from traditional light sources to light emitting diodes (LED). LEDs emit broad-spectrum white light, with a significant amount of photosynthetically active radiation, and typically a high content of blue light that regulates circadian rhythms in many organisms. While effects of the shift to LED have been investigated in nocturnal animals, its impact on primary producers is unknown. We performed three field experiments in a lowland agricultural drainage ditch to assess the impacts of a transition from high-pressure sodium (HPS) to white LED illumination (color temperature 4000 K) on primary producers in periphyton. In all experiments, we compared biomass and pigment composition of periphyton grown under a natural light regime to that of periphyton exposed to nocturnal HPS or, consecutively, LED light of intensities commonly found in urban waters (approximately 20 lux). Periphyton was collected in time series (1-13 weeks). We found no effect of HPS light on periphyton biomass; however, following a shift to LED the biomass decreased up to 62%. Neither light source had a substantial effect on pigment composition. The contrasting effects of the two light sources on biomass may be explained by differences in their spectral composition, and in particular the blue content. Our results suggest that spectral composition of the light source plays a role in determining the impacts of ALAN on periphyton and that the ongoing transition to LED may increase the ecological impacts of artificial lighting on aquatic primary producers. Reduced biomass in the base of the food web can impact ecosystem functions such as productivity and food supply for higher trophic levels in nocturnally-lit ecosystems. Copyright

  10. Estimation of Daily Air Temperature Based on MODIS Land Surface Temperature Products over the Corn Belt in the US

    Directory of Open Access Journals (Sweden)

    Linglin Zeng

    2015-01-01

    Full Text Available Air temperature (Ta is a key input in a wide range of agroclimatic applications. Moderate Resolution Imaging Spectroradiometer (MODIS Ts (Land Surface Temperature (LST products are widely used to estimate daily Ta. However, only daytime LST (Ts-day or nighttime LST (Ts-night data have been used to estimate Tmax/Tmin (daily maximum or minimum air temperature, respectively. The relationship between Tmax and Ts-night, and the one between Tmin and Ts-day has not been studied. In this study, both the ability of Ts-night data to estimate Tmax and the ability of Ts-day data to estimate Tmin were tested and studied in the Corn Belt during the growing season (May–September from 2008 to 2012, using MODIS daily LST products from both Terra and Aqua. The results show that using Ts-night for estimating Tmax could result in a higher accuracy than using Ts-day for a similar estimate. Combining Ts-day and Ts-night, the estimation of Tmax was improved by 0.19–1.85, 0.37–1.12 and 0.26–0.93 °C for crops, deciduous forest and developed areas, respectively, when compared with using only Ts-day or Ts-night data. The main factors influencing the Ta estimation errors spatially and temporally were analyzed and discussed, such as satellite overpassing time, air masses, irrigation, etc.

  11. Mitigate Strategy of Very High Temperature Reactor Air-ingress Accident

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Tae Kyu [KHNP CRI, Daejeon (Korea, Republic of); Arcilesi, David J.; Sun, Xiaodong; Christensen, Richard N. [The Ohio State University, Columbus (United States); Oh, Chang H.; Kim, Eung S. [Idaho National Laboratory, Idaho (United States)

    2016-10-15

    A critical safety event of the Very High Temperature Reactor (VHTR) is a loss-of-coolant accident (LOCA). Since a VHTR uses graphite as a core structure, if there is a break on the pressure vessel, the air in the reactor cavity could ingress into the reactor core. The worst case scenario of the accident is initiated by a double-ended guillotine break of the cross vessel that connects the reactor vessel and the power conversion unit. The operating pressures in the vessel and containment are about 7 and 0.1 MPa, respectively. In the VHTR, the reactor pressure vessel is located within a reactor cavity which is filled with air during normal operation. Therefore, the air-helium mixture in the cavity may ingress into the reactor pressure vessel after the depressurization process. In this paper, a commercial computational fluid dynamics (CFD) tool, FLUENT, was used to figure out air-ingress mitigation strategies in the gas-turbine modular helium reactor (GT-MHR) designed by General Atomics, Inc. After depressurization, there is almost no air in the reactor cavity; however, the air could flow back to the reactor cavity since the reactor cavity is placed in the lowest place in the reactor building. The heavier air could flow to the reactor cavity through free surface areas in the reactor building. Therefore, Argon gas injection in the reactor cavity is introduced. The injected argon would prevent the flow by pressurizing the reactor cavity initially, and eventually it prevents the flow by making the gas a heavier density than air in the reactor cavity. The gate opens when the reactor cavity is pressurized during the depressurization and it closes by gravity when the depressurization is terminated so that it can slow down the air flow to the reactor cavity.

  12. Adaptation to Life in the High Andes: Nocturnal Oxyhemoglobin Saturation in Early Development.

    Science.gov (United States)

    Hill, Catherine Mary; Baya, Ana; Gavlak, Johanna; Carroll, Annette; Heathcote, Kate; Dimitriou, Dagmara; L'Esperance, Veline; Webster, Rebecca; Holloway, John; Virues-Ortega, Javier; Kirkham, Fenella Jane; Bucks, Romola Starr; Hogan, Alexandra Marie

    2016-05-01

    Physiological adaptation to high altitude hypoxia may be impaired in Andeans with significant European ancestry. The respiratory 'burden' of sleep may challenge adaptation, leading to relative nocturnal hypoxia. Developmental aspects of sleep-related breathing in high-altitude native children have not previously been reported. We aimed to determine the influence of development on diurnal-nocturnal oxyhemoglobin differences in children living at high altitude. This was a cross-sectional, observational study. Seventy-five healthy Bolivian children aged 6 mo to 17 y, native to low altitude (500 m), moderate high altitude (2,500 m), and high altitude (3,700 m) were recruited. Daytime resting pulse oximetry was compared to overnight recordings using Masimo radical oximeters. Genetic ancestry was determined from DNA samples. Children had mixed European/Amerindian ancestry, with no significant differences between altitudes. Sixty-two participants had ≥ 5 h of nocturnal, artifact-free data. As predicted, diurnal mean oxyhemoglobin saturation decreased across altitudes (infants and children, both P sleep-related hypoxia in early childhood has potential lifespan implications. Future studies should characterize the sleep- related respiratory physiology underpinning our observations. © 2016 Associated Professional Sleep Societies, LLC.

  13. Cavity Ring-Down Absorption of O2 in Air as a Temperature Sensor for an Open and a Cryogenic Optical Cavity.

    Science.gov (United States)

    Nyaupane, Parashu R; Perez-Delgado, Yasnahir; Camejo, David; Wright, Lesley M; Manzanares, Carlos E

    2017-05-01

    The A-band of oxygen has been measured at low resolution at temperatures between 90 K and 373 K using the phase shift cavity ring down (PS-CRD) technique. For temperatures between 90 K and 295 K, the PS-CRD technique presented here involves an optical cavity attached to a cryostat. The static cell and mirrors of the optical cavity are all inside a vacuum chamber at the same temperature of the cryostat. The temperature of the cell can be changed between 77 K and 295 K. For temperatures above 295 K, a hollow glass cylindrical tube without windows has been inserted inside an optical cavity to measure the temperature of air flowing through the tube. The cavity consists of two highly reflective mirrors which are mounted parallel to each other and separated by a distance of 93 cm. In this experiment, air is passed through a heated tube. The temperature of the air flowing through the tube is determined by measuring the intensity of the oxygen absorption as a function of the wavenumber. The A-band of oxygen is measured between 298 K and 373 K, with several air flow rates. To obtain the temperature, the energy of the lower rotational state for seven selected rotational transitions is linearly fitted to a logarithmic function that contains the relative intensity of the rotational transition, the initial and final rotational quantum numbers, and the energy of the transition. Accuracy of the temperature measurement is determined by comparing the calculated temperature from the spectra with the temperature obtained from a calibrated thermocouple inserted at the center of the tube. This flowing air temperature sensor will be used to measure the temperatures of cooling air at the input (cold air) and output (hot air) after cooling the blades of a laboratory gas turbine. The results could contribute to improvements in turbine blade cooling design.

  14. Oxidation of graphites for core support post in air at high temperatures

    International Nuclear Information System (INIS)

    Imai, Hisashi; Fujii, Kimio; Kurosawa, Takeshi

    1982-07-01

    Oxidation reactions of candidate graphites for core support post with atmospheric air were studied in a temperature range between 550 0 C and 1000 0 C. The reaction rates, temperature dependence of the rates and distribution of bulk density in the oxidized graphites were measured and the characters obtained were compared between the brand of graphites. On the basis of the experimental results, dimension and strength of the post after corrosion with air, which might be introduced in rupture accident of primary coolant tube, were discussed. In the case of IG-11 graphite, it was proved that the strength of post is still sufficient even 100 hours after the beginning of the accident and that, however, it is necessary to insert more deeply the post against graphite blocks. (author)

  15. Hybridized electromagnetic-triboelectric nanogenerator for scavenging air-flow energy to sustainably power temperature sensors.

    Science.gov (United States)

    Wang, Xue; Wang, Shuhua; Yang, Ya; Wang, Zhong Lin

    2015-04-28

    We report a hybridized nanogenerator with dimensions of 6.7 cm × 4.5 cm × 2 cm and a weight of 42.3 g that consists of two triboelectric nanogenerators (TENGs) and two electromagnetic generators (EMGs) for scavenging air-flow energy. Under an air-flow speed of about 18 m/s, the hybridized nanogenerator can deliver largest output powers of 3.5 mW for one TENG (in correspondence of power per unit mass/volume: 8.8 mW/g and 14.6 kW/m(3)) at a loading resistance of 3 MΩ and 1.8 mW for one EMG (in correspondence of power per unit mass/volume: 0.3 mW/g and 0.4 kW/m(3)) at a loading resistance of 2 kΩ, respectively. The hybridized nanogenerator can be utilized to charge a capacitor of 3300 μF to sustainably power four temperature sensors for realizing self-powered temperature sensor networks. Moreover, a wireless temperature sensor driven by a hybridized nanogenerator charged Li-ion battery can work well to send the temperature data to a receiver/computer at a distance of 1.5 m. This work takes a significant step toward air-flow energy harvesting and its potential applications in self-powered wireless sensor networks.

  16. Six years of ground–air temperature tracking at Malence (Slovenia): thermal diffusivity from subsurface temperature data

    Czech Academy of Sciences Publication Activity Database

    Dědeček, Petr; Rajver, D.; Čermák, Vladimír; Šafanda, Jan; Krešl, Milan

    2013-01-01

    Roč. 10, č. 2 (2013), 025012/1-025012/9 ISSN 1742-2132 R&D Projects: GA ČR(CZ) GAP210/11/0183; GA MŠk LM2010008 Institutional support: RVO:67985530 Keywords : ground-air temperature coupling * thermal diffusivity * conductive-convective heat transfer Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.895, year: 2013

  17. The effect of air temperature on yield of Holstein dairy cattle

    OpenAIRE

    Anna Šimková; Miloslav Šoch; Kateřina Švejdová; Kristýna Šimák-Líbalová; Luboš Smutný; Šárka Smutná; Bohuslav Čermák; Iveta Novotná

    2015-01-01

    The study was carried out in the agricultural company Petrovice during the summer and winter seasons. The experiment included Holstein dairy cattle. Air temperature was measured using a data logger with sensors (Datalogger COMET 3120) in the stable. Data on average yield were taken from farm records and then processed using Microsoft Excel. The aim of the study was to determine how the values of ambient temperature affect the welfare of the animals with regard to the average performance. The ...

  18. Temporal and spatial assessments of minimum air temperature using satellite surface temperature measurements in Massachusetts, USA.

    Science.gov (United States)

    Kloog, Itai; Chudnovsky, Alexandra; Koutrakis, Petros; Schwartz, Joel

    2012-08-15

    Although meteorological stations provide accurate air temperature observations, their spatial coverage is limited and thus often insufficient for epidemiological studies. Satellite data expand spatial coverage, enhancing our ability to estimate near surface air temperature (Ta). However, the derivation of Ta from surface temperature (Ts) measured by satellites is far from being straightforward. In this study, we present a novel approach that incorporates land use regression, meteorological variables and spatial smoothing to first calibrate between Ts and Ta on a daily basis and then predict Ta for days when satellite Ts data were not available. We applied mixed regression models with daily random slopes to calibrate Moderate Resolution Imaging Spectroradiometer (MODIS) Ts data with monitored Ta measurements for 2003. Then, we used a generalized additive mixed model with spatial smoothing to estimate Ta in days with missing Ts. Out-of-sample tenfold cross-validation was used to quantify the accuracy of our predictions. Our model performance was excellent for both days with available Ts and days without Ts observations (mean out-of-sample R(2)=0.946 and R(2)=0.941 respectively). Furthermore, based on the high quality predictions we investigated the spatial patterns of Ta within the study domain as they relate to urban vs. non-urban land uses. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Analysis of Humid Air Turbine Cycle with Low- or Medium-Temperature Solar Energy

    Directory of Open Access Journals (Sweden)

    Hongbin Zhao

    2009-01-01

    Full Text Available A new humid air turbine cycle that uses low- or medium-temperature solar energy as assistant heat source was proposed for increasing the mass flow rate of humid air. Based on the combination of the first and second laws of thermodynamics, this paper described and compared the performances of the conventional and the solar HAT cycles. The effects of some parameters such as pressure ratio, turbine inlet temperature (TIT, and sollar collector efficiency on humidity, specific work, cycle's exergy efficiency, and solar energy to electricity efficiency were discussed in detail. Compared with the conventional HAT cycle, because of the increased humid air mass flow rate in the new system, the humidity and the specific work of the new system were increased. Meanwhile, the solar energy to electricity efficiency was greatly improved. Additionally, the exergy losses of components in the system under the given conditions were also studied and analyzed.

  20. Air - water temperature relationships in the trout streams of southeastern Minnesota’s carbonate - sandstone landscape

    Science.gov (United States)

    Krider, Lori A.; Magner, Joseph A.; Perry, Jim; Vondracek, Bruce C.; Ferrington, Leonard C.

    2013-01-01

    Carbonate-sandstone geology in southeastern Minnesota creates a heterogeneous landscape of springs, seeps, and sinkholes that supply groundwater into streams. Air temperatures are effective predictors of water temperature in surface-water dominated streams. However, no published work investigates the relationship between air and water temperatures in groundwater-fed streams (GWFS) across watersheds. We used simple linear regressions to examine weekly air-water temperature relationships for 40 GWFS in southeastern Minnesota. A 40-stream, composite linear regression model has a slope of 0.38, an intercept of 6.63, and R2 of 0.83. The regression models for GWFS have lower slopes and higher intercepts in comparison to surface-water dominated streams. Regression models for streams with high R2 values offer promise for use as predictive tools for future climate conditions. Climate change is expected to alter the thermal regime of groundwater-fed systems, but will do so at a slower rate than surface-water dominated systems. A regression model of intercept vs. slope can be used to identify streams for which water temperatures are more meteorologically than groundwater controlled, and thus more vulnerable to climate change. Such relationships can be used to guide restoration vs. management strategies to protect trout streams.

  1. Experimental study of air-cooled water condensation in slightly inclined circular tube using infrared temperature measurement technique

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungdae [Nuclear Engineering Department, Kyung Hee University, Yongin (Korea, Republic of); Kwon, Tae-Soon [Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Kim, Dong Eok, E-mail: dekim@knu.ac.kr [Department of Precision Mechanical Engineering, Kyungpook National University, Sangju (Korea, Republic of)

    2016-11-15

    Highlights: • Air-cooled condensation experiments in an inclined Pyrex glass tube were performed. • High-resolution wall temperature data and flow regime formations could be obtained. • The local heat flux was strongly dependent on the air-side heat transfer. • A CFD analysis was conducted for calculating the local heat flux distribution. - Abstract: This study presents the results of an investigation of the air-cooled water condensation heat transfer characteristics inside a slightly inclined circular tube made of transparent Pyrex glass. The high-resolution wall temperature data and stratified film formations could be obtained with the assistance of an infrared (IR) thermometry technique and side-view visualization using a CCD camera. In all experimental cases, the condensation flow patterns were in the fully-stratified flow region. In addition, the experimentally measured void fraction corresponded well with the logarithmic mean void fraction model. The local temperature differences in the cooling air flow across the condenser tube and high-resolution temperature profiles on the tube’s outer wall were obtained in the experimental measurements. Under the experimental conditions of this study, the local heat flux distributions in the longitudinal direction of the test tube were strongly dependent on the cooling air velocity. And, with the help of IR thermometry, the tube outer wall temperature data at 45 local points could be measured. From the data, the asymmetry distribution of the local wall temperatures and the accurate location of the transition from two-phase mixture to single phase liquid inside the tube could be obtained. Also, the analysis of the thermal resistances by condensation, wall conduction and air convection showed that the air convective heat transfer behavior can play a dominant role to the local heat transfer characteristics. Finally, in order to obtain the local heat flux distribution along the tube’s outer wall, a two

  2. Plasma-catalytic reforming of ethanol: influence of air activation rate and reforming temperature

    International Nuclear Information System (INIS)

    Nedybaliuk, O.A.; Chernyak, V.Ya.; Fedirchuk, I.I.; Demchina, V.P.; Bortyshevsky, V.A.; Korzh, R.V.

    2016-01-01

    This paper presents the study of the influence that air activation rate and reforming temperature have on the gaseous products composition and conversion efficiency during the plasma-catalytic reforming of ethanol. The analysis of product composition showed that the conversion efficiency of ethanol has a maximum in the studied range of reforming temperatures. Researched system provided high reforming efficiency and high hydrogen energy yield at the lower temperatures than traditional conversion technologies

  3. Increased temperature tolerance of the air-breathing Asian swamp eel Monopterus albus after high-temperature acclimation is not explained by improved cardiorespiratory performance.

    Science.gov (United States)

    Lefevre, S; Findorf, I; Bayley, M; Huong, D T T; Wang, T

    2016-01-01

    This study investigated the hypothesis that in the Asian swamp eel Monopterus albus, an air-breathing fish from south-east Asia that uses the buccopharyngeal cavity for oxygen uptake, the upper critical temperature (TU) is increased by acclimation to higher temperature, and that the increased TU is associated with improved cardiovascular and respiratory function. Monopterus albus were therefore acclimated to 27° C (current average) and 32° C (current maximum temperature as well as projected average within 100-200 years), and both the effect of acclimation and acute temperature increments on cardiovascular and respiratory functions were investigated. Two weeks of heat acclimation increased upper tolerated temperature (TU ) by 2° C from 36·9 ± 0·1° C to 38·9 ± 0·1° C (mean ± s.e.). Oxygen uptake (M˙O2) increased with acclimation temperature, accommodated by increases in both aerial and aquatic respiration. Overall, M˙O2 from air (M˙O2a ) was predominant, representing 85% in 27° C acclimated fish and 80% in 32° C acclimated fish. M˙O2 increased with acute increments in temperature and this increase was entirely accommodated by an increase in air-breathing frequency and M˙O2a . Monopterus albus failed to upregulate stroke volume; rather, cardiac output was maintained through increased heart rate with rising temperature. Overall, acclimation of M. albus to 32° C did not improve its cardiovascular and respiratory performance at higher temperatures, and cardiovascular adaptations, therefore, do not appear to contribute to the observed increase in TU. © 2015 The Fisheries Society of the British Isles.

  4. Monosymptomatic nocturnal enuresis

    Directory of Open Access Journals (Sweden)

    Bertan Karaboğa

    2012-03-01

    Full Text Available Enuresis Nocturna is the most common urologic problemin childhood. There is not a consensus about terminology.Terminology identified by The International Children’sContinence Society (ICCS is recommended. Bed-wettingat night during sleep (incontinence in children above 5years of age who don’t have congenital or acquired centralnervous system defect is defined as enuresis nocturna.There are two groups monosymptomatic (simpleand non-monosymptomatic (complicated. Monosymptomaticenuresis nocturna (MNE has no symptoms otherthan bed-wetting at night during sleep. Various theoriesconcerning etiology of MNE has been suggested; one ormore of genetic, hormonal, bladder associated and sleepdisorders are stated to play a role. Self-improvement canbe achieved each year by 15% increasing maturity. Underpinning treatment and in addition to this unique treatmentmust be done by considering the factors in the pathophysiology.The success of the treatment and roadmapto be followed must be arrange with child and family. Thepurpose of this eclectic is; evaluation of correct diagnosis,differential diagnosis, patient follow-up and treatment optionsof the cases applicant with nocturnal enuresis basedon the current knowledge of ICCS and Turkey EnuresisTreatment Guide.

  5. The impact of elevated CO2 and temperature on grain quality of rice grown under open-air field conditions.

    Science.gov (United States)

    Jing, Liquan; Wang, Juan; Shen, Shibo; Wang, Yunxia; Zhu, Jianguo; Wang, Yulong; Yang, Lianxin

    2016-08-01

    Rising atmospheric CO2 is accompanied by global warming. However, interactive effects of elevated CO2 and temperature have not been well studied on grain quality of rice. A japonica cultivar was grown in the field using a free-air CO2 enrichment facility in combination with a canopy air temperature increase system in 2014. The gas fumigation (200 µmol mol(-1) above ambient CO2 ) and temperature increase (1 °C above ambient air temperature) were performed from tillering until maturity. Compared with the control (ambient CO2 and air temperature), elevated CO2 increased grain length and width as well as grain chalkiness but decreased protein concentrations. In contrast, the increase in canopy air temperature had less effect on these parameters except for grain chalkiness. The starch pasting properties of rice flour and taste analysis of cooked rice indicated that the palatability of rice was improved by CO2 and/or temperature elevation, with the combination of the two treatments showing the most significant changes compared with ambient rice. It is concluded that projected CO2 in 2050 may have larger effects on rice grain quality than the projected temperature increase. Although deterioration in milling suitability, grain appearance and nutritional quality can be expected, the taste of cooked rice might be better in the future environment. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  6. Alanine aminotransferase is associated with an adverse nocturnal blood glucose profile in individuals with normal glucose regulation.

    Directory of Open Access Journals (Sweden)

    Jian Zhou

    Full Text Available OBJECTIVE: Although the association between alanine aminotransferase (ALT levels and risk of type 2 diabetes is well-studied, the effects of slightly increased ALT levels within the normal range on the temporal normal glucose profile remains poorly understood. METHODS: A total of 322 Chinese subjects without impaired glucose tolerance or previous diagnoses of diabetes were recruited for study from 10 hospitals in urban areas across China. All subjects wore a continuous glucose monitoring (CGM system for three consecutive days. The diurnal (06∶00-20∶00 and nocturnal (20∶00-06∶00 mean blood glucose (MBG levels were calculated. Subjects were stratified by ALT quartile level and correlation analyses were performed. RESULTS: The median ALT level was 17 IU/L, and subjects with ALT ≥17 IU/L had higher nocturnal MBG level than those with ALT 0.05. Multivariate stepwise regression analysis of elevated nocturnal MBG identified increased HOMA-IR, elevated ALT levels, and decreased homeostatic model assessment of ß-cell function as independent factors (all, P<0.05. CONCLUSIONS: Mildly elevated ALT levels, within the normal range, are associated with unfavorable nocturnal glucose profiles in Chinese subjects with normal glucose regulation.

  7. Picosecond ballistic imaging of diesel injection in high-temperature and high-pressure air

    Science.gov (United States)

    Duran, Sean P.; Porter, Jason M.; Parker, Terence E.

    2015-04-01

    The first successful demonstration of picosecond ballistic imaging using a 15-ps-pulse-duration laser in diesel sprays at temperature and pressure is reported. This technique uses an optical Kerr effect shutter constructed from a CS2 liquid cell and a 15-ps pulse at 532 nm. The optical shutter can be adjusted to produce effective imaging pulses between 7 and 16 ps. This technique is used to image the near-orifice region (first 3 mm) of diesel sprays from a high-pressure single-hole fuel injector. Ballistic imaging of dodecane and methyl oleate sprays injected into ambient air and diesel injection at preignition engine-like conditions are reported. Dodecane was injected into air heated to 600 °C and pressurized to 20 atm. The resulting images of the near-orifice region at these conditions reveal dramatic shedding of the liquid near the nozzle, an effect that has been predicted, but to our knowledge never before imaged. These shedding structures have an approximate spatial frequency of 10 mm-1 with lengths from 50 to 200 μm. Several parameters are explored including injection pressure, liquid fuel temperature, air temperature and pressure, and fuel type. Resulting trends are summarized with accompanying images.

  8. Measurement of the temperature Gradient in air using Talbot effect and Moire technique

    International Nuclear Information System (INIS)

    Tavassoly, M.T.; Rasouli, S.

    2000-01-01

    In this paper we have exploited the self-imaging or Talbot effect and Moire technique to measure the temperature distribution in the air enclosed between two paral led plates of different temperatures. This study shows that for the plates width of 60 cm a change of 1 d egC in 1 cm can be easily detected

  9. [Nocturnal hypoxemia and arrhythmia in patients with chronic obstructive lung diseases (COLD)].

    Science.gov (United States)

    Skwarski, K

    1989-05-01

    A decrease in the arterial blood saturation by oxygen in patients with POChP is a frequent phenomenon. It is more serious in patients type blue boaters and less frequent among patients type pink puffers. The aim of the paper was to compare the arterial blood saturation by oxygen in the groups examined during two nights: during the first night the patients breathed atmospheric air whereas during the second night they were given oxygen. The author also studied the influence of oxygenation of an organism on the frequency of cardiac rhythm disorders (ZRS). The author examined a group of 20 patients with the predominance of chronic bronchitis--blue boaters (average VC was 1.95 l, FEV1--0.81 l, PaO2 while breathing atmospheric air 52 mm Hg and 68 mm Hg after giving oxygen, PaCO2 47 and 51 mm Hg respectively) and 20 patients with the predominance of emphysema--pink puffers (average VC--2.30 l, FEV1--0.86 l, PaO2 while breathing atmospheric air 60 mm Hg and 70 mm Hg after giving oxygen, PaCO2 39 and 40 mm respectively). It was found that the patients with heavy hypoxaemia and hypercapnia had worse arterial blood saturation by oxygen during the two nights of investigation in comparison with the other group. The author also found more frequent cardiac rhythm disorders in this group of patients. Giving oxygen improved blood oxygenation in the two groups and lowered the frequency of cardiac rhythm disorders. The results obtained indicate to the need of oxygen therapy in patients with advanced POChP, especially during the night so as to avoid nocturnal hypoxaemia of an organism.

  10. Nocturnal enuresis in school‑aged children with sickle‑cell anemia ...

    African Journals Online (AJOL)

    2016-05-09

    May 9, 2016 ... socioeconomic class, and sibling history of enuresis were not statistically ... and parental history of childhood enuresis are significant risk factors. .... adolescents with SCA may be at a higher risk of nocturnal ..... Thus, factors which contribute to ... in male children,[30] and more frequent developmental delays ...

  11. Working for Food Shifts Nocturnal Mouse Activity into the Day

    NARCIS (Netherlands)

    Hut, Roelof A.; Pilorz, Violetta; Boerema, Ate S.; Strijkstra, Arjen M.; Daan, Serge; Yamazaki, Shin

    2011-01-01

    Nocturnal rodents show diurnal food anticipatory activity when food access is restricted to a few hours in daytime. Timed food access also results in reduced food intake, but the role of food intake in circadian organization per se has not been described. By simulating natural food shortage in mice

  12. Comparing effects of insulin analogues and human insulin on nocturnal glycaemia in hypoglycaemia-prone people with Type 1 diabetes

    DEFF Research Database (Denmark)

    Kristensen, P. L.; Tarnow, L.; Bay, C.

    2017-01-01

    . Conclusions: Treatment with insulin analogue reduces the occurrence of nocturnal hypoglycaemia assessed by nocturnal glucose profiles in people with Type 1 diabetes prone to severe hypoglycaemia. Nocturnal glucose profiles provide a more comprehensive assessment of clinical benefit of insulin regimens......Aims: To assess the difference between analogue and human insulin with regard to nocturnal glucose profiles and risk of hypoglycaemia in people with recurrent severe hypoglycaemia. Methods: A total of 72 people [46 men, mean ± sd age 54 ± 12 years, mean ± sd HbA1c 65 ± 12 mmol/mol (8.1 ± 1.1......%), mean ± sd duration of diabetes 30 ± 14 years], who participated in a 2-year randomized, crossover trial of basal-bolus therapy with insulin detemir/insulin aspart or human NPH insulin/human regular insulin (the HypoAna trial) were studied for 2 nights during each treatment. Venous blood was drawn...

  13. Experimental Study of the Performance of Air Source Heat Pump Systems Assisted by Low-Temperature Solar-Heated Water

    Directory of Open Access Journals (Sweden)

    Jinshun Wu

    2013-01-01

    Full Text Available Due to the low temperatures, the heating efficiency of air source heat pump systems during the winter is very low. To address this problem, a low-temperature solar hot water system was added to a basic air source heat pump system. Several parameters were tested and analyzed. The heat collection efficiency of the solar collector was analyzed under low-temperature conditions. The factors that affect the performance of the heat pumps, such as the fluid temperature, pressure, and energy savings, were analyzed for cases where the solar energy auxiliary heat pump and the air source heat pump are used independently. The optimal heating temperature and the changes in the fluid temperature were determined. The influence of the compression ratio and the coefficient of performance (COP were investigated theoretically. The results revealed the parameters that are important to the performance of the system. Several measures for improving the COP of the heat pump units are provided for other applications and future research.

  14. The risk of hyponatremia with desmopressin use for nocturnal polyuria.

    Science.gov (United States)

    Choi, Eun Young; Park, Joon-Sung; Kim, Yong Tae; Park, Sung Yul; Kim, Gheun-Ho

    2015-01-01

    Desmopressin is used for treating nocturnal polyuria, but hyponatremia is an associated concern in the elderly due to impaired urinary dilution. This study was undertaken to characterize hyponatremia occurring in adults using desmopressin for nocturnal polyuria. Data from 172 patients who were prescribed desmopressin for nocturnal polyuria at a urology clinic from September 2010 through February 2013 were retrospectively analyzed. Demographic and laboratory parameters were investigated to examine the risk factors for desmopressin-associated hyponatremia. The average follow-up serum sodium measured 21 ± 22 days after using desmopressin was 138 ± 5 mmol/l. Hyponatremia (<135 mmol/l) was found in 24 patients (14%), and it was severe in 7 (<126 mmol/l). In the hyponatremic patients, serum sodium decreased by 11 ± 6 mmol/l. Patients with hyponatremia were older than those with normonatremia (78 ± 7 vs. 68 ± 9 years, p < 0.0001). The presence of either hyponatremia-predisposing comorbidities or concurrent medications was associated with hyponatremia. Patients with hyponatremia had lower basal hemoglobin (11 ± 2 vs. 13 ± 2 g/dl, p < 0.001) and serum sodium (139 ± 2 vs. 140 ± 2 mmol/l, p < 0.05) than those with normonatremia. Multivariate logistic regression after adjustment for basal serum sodium showed that advanced age (OR 1.15; 95% CI 1.03-1.27) and lower hemoglobin level (OR 0.64; 95% CI 0.43-0.94) were independently associated with hyponatremia. Hyponatremia is not infrequently associated with desmopressin use. Those with advanced age (≥65 years) and lower hemoglobin are at risk of desmopressin-associated hyponatremia and need to be carefully monitored. © 2015 S. Karger AG, Basel.

  15. Climate Change in Alpine Regions - Regional Characteristics of a Global Phenomenon by the Example of Air Temperature

    Science.gov (United States)

    Lang, Erich; Stary, Ulrike

    2017-04-01

    For nearly 50 years the Austrian Research Centre for Forests (BFW) has been engaged in research in the Alpine region recording measuring data at extreme sites. Data series of this duration provide already a good insight into the evolution of climate parameters. Extrapolations derived from it are suitable for comparison with results from climate change models or supplement them with regard to their informative value. This is useful because climate change models describe a simplified picture of reality based on the size of the data grid they use. Analysis of time series of two air temperature measuring stations in different torrent catchment areas indicate that 1) predictions of temperature rise for the Alpine region in Austria will have to be revised upwards, and 2) only looking at the data of seasons (or shorter time periods), reveals the real dramatic effect of climate change. Considering e.g. the annual average data of air temperature of the years 1969-2016 at the climate station "Fleissner" (altitude 1210m a.s.l; Upper Mölltal, Carinthia) a significant upward trend is visible. Using a linear smoothing function an increase of the average annual air temperature of about 2.2°C within 50 years emerges. The calculated temperature rise thus confirms the general fear of an increase of more than 2.0°C till the middle of the 21st century. Looking at the seasonal change of air temperature, significant positive trends are shown in all four seasons. But the level of the respective temperature increase varies considerably and indicates the highest increase in spring (+3.3°C), and the lowest one in autumn (+1.3°C, extrapolated for a time period of 50 years). The maximum increase of air temperature at the measuring station "Pumpenhaus" (altitude 980m a.s.l), which is situated in the "Karnische Alpen" in the south of Austria, is even stronger. From a time series of 28 years (with data recording starting in 1989) the maximum rise of temperature was 5.4°C detected for the

  16. Modeling Air Temperature/Water Temperature Relations Along a Small Mountain Stream Under Increasing Urban Influence

    Science.gov (United States)

    Fedders, E. R.; Anderson, W. P., Jr.; Hengst, A. M.; Gu, C.

    2017-12-01

    Boone Creek is a headwater stream of low to moderate gradient located in Boone, North Carolina, USA. Total impervious surface coverage in the 5.2 km2 catchment drained by the 1.9 km study reach increases from 13.4% in the upstream half of the reach to 24.3% in the downstream half. Other markers of urbanization, including culverting, lack of riparian shade vegetation, and bank armoring also increase downstream. Previous studies have shown the stream to be prone to temperature surges on short timescales (minutes to hours) caused by summer runoff from the urban hardscaping. This study investigates the effects of urbanization on the stream's thermal regime at daily to yearly timescales. To do this, we developed an analytical model of daily average stream temperatures based on daily average air temperatures. We utilized a two-part model comprising annual and biannual components and a daily component consisting of a 3rd-order Markov process in order to fit the thermal dynamics of our small, gaining stream. Optimizing this model at each of our study sites in each studied year (78 total site-years of data) yielded annual thermal exchange coefficients (K) for each site. These K values quantify the strength of the relationship between stream and air temperature, or inverse thermal stability. In a uniform, pristine catchment environment, K values are expected to decrease downstream as the stream gains discharge volume and, therefore, thermal inertia. Interannual average K values for our study reach, however, show an overall increase from 0.112 furthest upstream to 0.149 furthest downstream, despite a near doubling of stream discharge between these monitoring points. K values increase only slightly in the upstream, less urban, half of the reach. A line of best fit through these points on a plot of reach distance versus K value has a slope of 2E-6. But the K values of downstream, more urbanized sites increase at a rate of 2E-5 per meter of reach distance, an order of magnitude

  17. Generation of low-temperature air plasma for food processing

    Science.gov (United States)

    Stepanova, Olga; Demidova, Maria; Astafiev, Alexander; Pinchuk, Mikhail; Balkir, Pinar; Turantas, Fulya

    2015-11-01

    The project is aimed at developing a physical and technical foundation of generating plasma with low gas temperature at atmospheric pressure for food industry needs. As known, plasma has an antimicrobial effect on the numerous types of microorganisms, including those that cause food spoilage. In this work an original experimental setup has been developed for the treatment of different foods. It is based on initiating corona or dielectric-barrier discharge in a chamber filled with ambient air in combination with a certain helium admixture. The experimental setup provides various conditions of discharge generation (including discharge gap geometry, supply voltage, velocity of gas flow, content of helium admixture in air and working pressure) and allows for the measurement of the electrical discharge parameters. Some recommendations on choosing optimal conditions of discharge generation for experiments on plasma food processing are developed.

  18. Borehole temperatures, climate change and the pre-observational surface air temperature mean: allowance for hydraulic conditions

    Czech Academy of Sciences Publication Activity Database

    Bodri, L.; Čermák, Vladimír

    2005-01-01

    Roč. 45, č. 4 (2005), s. 265-276 ISSN 0921-8181 R&D Projects: GA AV ČR IAA3012005; GA ČR GA205/03/0998; GA AV ČR KSK3046108 Institutional research plan: CEZ:AV0Z3012916 Keywords : climate change * global warming * surface air temperature Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 2.223, year: 2005

  19. Treatment of paroxysmal nocturnal hemoglobinuria

    Directory of Open Access Journals (Sweden)

    I. A. Lisukov

    2014-07-01

    Full Text Available Paroxysmal nocturnal hemoglobinuria (PNH is a rare, life‑threatening clonal hematological disorder caused by an acquired mutation in the phosphatidylinositol glucan (PIG-A gene. PNH is characterized by chronic intravascular hemolysis, marrow failure, thrombophilia and other severe clinical syndromes. Until recently, the treatment of PNH has been symptomatic with blood transfusions, anticoagulation and supplementation with folic acid or iron. The only potentially curative treatment is allogeneic stem cell transplantation, but this has severe complications with high mortality rates. A new targeted treatment strategy is the inhibition of the terminal complement cascade with anti‑C5 monoclonal antibody (eculizumab. Eculizumab has shown significant efficacy in controlling of intravascular hemolysis resulting in improving quality of life and survival.

  20. Treatment of paroxysmal nocturnal hemoglobinuria

    Directory of Open Access Journals (Sweden)

    I. A. Lisukov

    2012-01-01

    Full Text Available Paroxysmal nocturnal hemoglobinuria (PNH is a rare, life‑threatening clonal hematological disorder caused by an acquired mutation in the phosphatidylinositol glucan (PIG-A gene. PNH is characterized by chronic intravascular hemolysis, marrow failure, thrombophilia and other severe clinical syndromes. Until recently, the treatment of PNH has been symptomatic with blood transfusions, anticoagulation and supplementation with folic acid or iron. The only potentially curative treatment is allogeneic stem cell transplantation, but this has severe complications with high mortality rates. A new targeted treatment strategy is the inhibition of the terminal complement cascade with anti‑C5 monoclonal antibody (eculizumab. Eculizumab has shown significant efficacy in controlling of intravascular hemolysis resulting in improving quality of life and survival.

  1. Corresponding Relation between Warm Season Precipitation Extremes and Surface Air Temperature in South China

    Institute of Scientific and Technical Information of China (English)

    SUN; Wei; LI; Jian; YU; Ru-Cong

    2013-01-01

    Hourly data of 42 rain gauges over South China during 1966–2005 were used to analyze the corresponding relation between precipitation extremes and surface air temperature in the warm season(May to October).The results show that below 25℃,both daily and hourly precipitation extremes in South China increase with rising temperature.More extreme events transit to the two-time Clausius-Clapeyron(CC)relationship at lower temperatures.Daily as well as hourly precipitation extremes have a decreasing tendency nearly above 25℃,among which the decrease of hourly extremes is much more significant.In order to investigate the efects of rainfall durations,hourly precipitation extremes are presented by short duration and long duration precipitation,respectively.Results show that the dramatic decrease of hourly rainfall intensities above 25℃ is mainly caused by short duration precipitation,and long duration precipitation extremes rarely occur in South China when surface air temperature surpasses 28℃.

  2. Mapping of Daily Mean Air Temperature in Agricultural Regions Using Daytime and Nighttime Land Surface Temperatures Derived from TERRA and AQUA MODIS Data

    Directory of Open Access Journals (Sweden)

    Ran Huang

    2015-07-01

    Full Text Available Air temperature is one of the most important factors in crop growth monitoring and simulation. In the present study, we estimated and mapped daily mean air temperature using daytime and nighttime land surface temperatures (LSTs derived from TERRA and AQUA MODIS data. Linear regression models were calibrated using LSTs from 2003 to 2011 and validated using LST data from 2012 to 2013, combined with meteorological station data. The results show that these models can provide a robust estimation of measured daily mean air temperature and that models that only accounted for meteorological data from rural regions performed best. Daily mean air temperature maps were generated from each of four MODIS LST products and merged using different strategies that combined the four MODIS products in different orders when data from one product was unavailable for a pixel. The annual average spatial coverage increased from 20.28% to 55.46% in 2012 and 28.31% to 44.92% in 2013.The root-mean-square and mean absolute errors (RMSE and MAE for the optimal image merging strategy were 2.41 and 1.84, respectively. Compared with the least-effective strategy, the RMSE and MAE decreased by 17.2% and 17.8%, respectively. The interpolation algorithm uses the available pixels from images with consecutive dates in a sliding-window mode. The most appropriate window size was selected based on the absolute spatial bias in the study area. With an optimal window size of 33 × 33 pixels, this approach increased data coverage by up to 76.99% in 2012 and 89.67% in 2013.

  3. Fire simulation in large compartments with a fire model 'CFAST'. Part 1. Survey of applicability for analyzing air-temperature profile in compartments

    International Nuclear Information System (INIS)

    Hattori, Yasuo; Suto, Hitoshi; Shirai, Koji; Eguchi, Yuzuru; Sano, Tadashi

    2012-01-01

    The basic performance of numerical analysis of air-temperature profiles in large-scale compartments by using a zone model, CFAST (Consolidated model of Fire growth And Smoke Transport), which has been widely applied for fire protection design of buildings is examined. Special attentions are paid to the dependence of the setting boundary conditions and the choosing model parameters. The simulations carried out under the denkyoken-test conditions, in which the air-temperature profiles in compartments and the heat-release rate of a fire have been precisely measured, indicate that the CFAST has a capability to appropriately represent the time-histories of air-temperature in the high air-temperature layer generated in the vicinity of ceiling of the compartment which includes the source of a fire, by applying the proper boundary conditions, i.e., time-histories of air-temperature in the upper (high temperature) layer given by the CFAST agree well with those of observations. The sensitivity analysis in the simulations also reveals that the appropriately setting of the boundary-conditions, especially for the heat-release ratio from a fire and the heat-transfer rate from walls of compartments to ambient air is vital. Contrary to this, the impacts of choosing numerical parameters on the air-temperature analysis are quite small. (author)

  4. [Temperature that modifies the effect of air pollution on emergency room visits for circulatory and respiratory diseases in Beijing, China].

    Science.gov (United States)

    Wang, L L; Zhang, Q; Bai, R H; Mi, B B; Yan, H

    2017-08-10

    Objective: To analyze the temperature modification effect on emergency room visits for circulatory and respiratory diseases caused by air pollution, in Beijing. Methods: Data on both circulatory and respiratory diseases in 2010 and 2011 were collected, Both meteorological and air pollutants related data were obtained from the National Scientific Data Sharing Platform for Population and Health. By using the stratified time-series models, we analyzed the effects of air pollution on emergency room visits for circulatory and respiratory diseases under different temperature zones, from 2010 to 2011, in Beijing. Results: Low temperature (daily average temperatureeffect of air pollution index (API) on emergency room visits for circulatory diseases, Under 10 units of API, the relative risks and confidence interval appeared as 1.067 (1.054-1.080). However, high (daily average temperature between 24.4 ℃ and 28.5 ℃) and extra-high temperature (daily average temperature >28.5 ℃) could enhance the effect of API on emergency room visits for respiratory diseases, Under 10 units of API, the relative risks and confidence interval were 1.021 (1.015-1.028) and 1.006 (1.003-1.008), respectively. Conclusion: Temperature seemed to have modified the association between air pollution and both circulatory and respiratory diseases.

  5. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria

    2013-01-01

    environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film......The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink...

  6. Improvement of resistant hypertension by nocturnal hemodialysis in a patient with end-stage kidney disease.

    Science.gov (United States)

    Tang, Xiaojing; Hu, Xiaohong; Mei, Changlin; Yu, Shengqiang

    2015-01-01

    Resistant hypertension is a common and refractory complication of hemodialysis (HD) patients and is associated with a higher risk of cardiovascular morbidity and mortality. Here we present a case of resistant hypertension treated successfully by nocturnal HD. A 63-year-old female with end-stage kidney disease was hospitalized for severe headache, objective vertigo and persistent vomiting for 1 month on February 6, 2012. She had been on intermittent HD for 3 months, and her blood pressure maintained 200-240/100-130 mm Hg even after using 7 kinds of antihypertensive drugs including olmesartan, benazepril, nitrendipine, arotinolol, terazosin, clonidine and torasemide. A CT of the abdomen revealed a mild hyperplasia of the left adrenal gland (fig. 1). However, plasma renin, angiotensin and aldosterone were all within the normal range. Nocturnal extended HD was initiated with a blood flow rate of 150 ml/min and a dialysis time of 7 h. After 3 months of nocturnal HD, all symptoms were relieved and her systolic blood pressure started to decrease by 10-20 mm Hg. Six months later, the predialysis blood pressure was decreased to 140-160/90-100 mm Hg and the antihypertensive drugs were reduced to 4 kinds. Meanwhile, the blood biochemical parameters including hemoglobin, serum calcium, phosphate and parathyroid hormone were all controlled well during 2 years of treatment. This case indicates that nocturnal extended HD is probably a promising and effective choice for resistant hypertension in HD patients.

  7. Extended driving impairs nocturnal driving performances.

    Directory of Open Access Journals (Sweden)

    Patricia Sagaspe

    Full Text Available Though fatigue and sleepiness at the wheel are well-known risk factors for traffic accidents, many drivers combine extended driving and sleep deprivation. Fatigue-related accidents occur mainly at night but there is no experimental data available to determine if the duration of prior driving affects driving performance at night. Participants drove in 3 nocturnal driving sessions (3-5 am, 1-5 am and 9 pm-5 am on open highway. Fourteen young healthy men (mean age [+/-SD] = 23.4 [+/-1.7] years participated Inappropriate line crossings (ILC in the last hour of driving of each session, sleep variables, self-perceived fatigue and sleepiness were measured. Compared to the short (3-5 am driving session, the incidence rate ratio of inappropriate line crossings increased by 2.6 (95% CI, 1.1 to 6.0; P<.05 for the intermediate (1-5 am driving session and by 4.0 (CI, 1.7 to 9.4; P<.001 for the long (9 pm-5 am driving session. Compared to the reference session (9-10 pm, the incidence rate ratio of inappropriate line crossings were 6.0 (95% CI, 2.3 to 15.5; P<.001, 15.4 (CI, 4.6 to 51.5; P<.001 and 24.3 (CI, 7.4 to 79.5; P<.001, respectively, for the three different durations of driving. Self-rated fatigue and sleepiness scores were both positively correlated to driving impairment in the intermediate and long duration sessions (P<.05 and increased significantly during the nocturnal driving sessions compared to the reference session (P<.01. At night, extended driving impairs driving performances and therefore should be limited.

  8. Integrated LTCC Pressure/Flow/Temperature Multisensor for Compressed Air Diagnostics†

    Directory of Open Access Journals (Sweden)

    Nicolas Craquelin

    2010-12-01

    Full Text Available We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues.

  9. Integrated LTCC pressure/flow/temperature multisensor for compressed air diagnostics.

    Science.gov (United States)

    Fournier, Yannick; Maeder, Thomas; Boutinard-Rouelle, Grégoire; Barras, Aurélie; Craquelin, Nicolas; Ryser, Peter

    2010-01-01

    We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues.

  10. Integrated LTCC Pressure/Flow/Temperature Multisensor for Compressed Air Diagnostics†

    Science.gov (United States)

    Fournier, Yannick; Maeder, Thomas; Boutinard-Rouelle, Grégoire; Barras, Aurélie; Craquelin, Nicolas; Ryser, Peter

    2010-01-01

    We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues. PMID:22163518

  11. Effects of work stress on work-related rumination, restful sleep, and nocturnal heart rate variability experienced on workdays and weekends.

    Science.gov (United States)

    Vahle-Hinz, Tim; Bamberg, Eva; Dettmers, Jan; Friedrich, Niklas; Keller, Monika

    2014-04-01

    The present study reports the lagged effects of work stress on work-related rumination, restful sleep, and nocturnal heart rate variability experienced during both workdays and weekends. Fifty employees participated in a diary study. Multilevel and regression analyses revealed a significant relationship between work stress measured at the end of a workday, work-related rumination measured during the evening, and restful sleep measured the following morning. Work stress, measured as the mean of 2 consecutive workdays, was substantially but not significantly related to restful sleep on weekends. Work stress was unrelated to nocturnal heart rate variability. Work-related rumination was related to restful sleep on weekends but not on workdays. Additionally, work-related rumination on weekends was positively related to nocturnal heart rate variability during the night between Saturday and Sunday. No mediation effects of work stress on restful sleep or nocturnal heart rate variability via work-related rumination were confirmed.

  12. The influence of air temperature and relative humidity on dynamics of water potential in Betula pendula (Betulaceae trees

    Directory of Open Access Journals (Sweden)

    G. P. Тikhova

    2017-02-01

    Full Text Available Linear multiple models were developed to describe diurnal and seasonal dynamics of water potential (Ψ of the foliated shoots in the plants of Betula genus related to air temperature and relative humidity in the middle taiga (southern Karelia. The results of the study revealed unidirectional changes, but different effect strength of air temperature and relative humidity on Ψ of the foliated shoots of common silver birch (Betula pendula Roth and curly (Karelian birch (Betula pendula Roth var. carelica. It was shown that increasing air temperature 1°С results in similar decreasing of Ψ value equal to 0.037–0.038 MPa in both of the birches (p > 0.05. Since the diurnal air temperature range achieves 10–15 °С, the contribution of this factor may be up to 0.57 MPa. On the contrary, the contribution of relative air humidity to Ψ value differs significantly in distinct birch forms (p < 0.05. In this case the change range of Ψ value in silver birch and curly birch may be up to 0.46 (0.015 MPa/1 % RH and 0.52 МПа (0.017 MPa/1 % RH, respectively. The results indicate that curly birch responds to the increase of relative air humidity with higher magnification of Ψ in comparison with common silver birch.

  13. BOREAS TE-6 1994 Soil and Air Temperatures in the NSA

    Science.gov (United States)

    Hall, Forrest G. (Editor); Curd, Shelaine (Editor); Norman, John; Wilson, Tim

    2000-01-01

    The BOREAS TE-6 team collected several data sets to examine the influence of vegetation, climate, and their interactions on the major carbon fluxes for boreal forest species. This data set contains measurements of the air temperature at a single height and soil temperature at several depths in the NSA from 25-May to 08-Oct- 1994. Chromel-Constantan thermocouple wires run by a miniprogrammable data logger (Model 21X, Campbell Scientific, Inc., Logan, UT) provided direct measurements of temperature. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distrobuted Activity Archive Center (DAAC).

  14. Effect of low air velocities on thermal homeostasis and comfort during exercise at space station operational temperature and humidity

    Science.gov (United States)

    Beumer, Ronald J.

    1989-01-01

    The effectiveness of different low air velocities in maintaining thermal comfort and homeostasis during exercise at space station operational temperature and humidity was investigated. Five male subjects exercised on a treadmill for successive ten minute periods at 60, 71, and 83 percent of maximum oxygen consumption at each of four air velocities, 30, 50, 80, and 120 ft/min, at 22 C and 62 percent relative humidity. No consistent trends or statistically significant differences between air velocities were found in body weight loss, sweat accumulation, or changes in rectal, skin, and body temperatures. Occurrence of the smallest body weight loss at 120 ft/min, the largest sweat accumulation at 30 ft/min, and the smallest rise in rectal temperature and the greatest drop in skin temperature at 120 ft/min all suggested more efficient evaporative cooling at the highest velocity. Heat storage at all velocities was evidenced by increased rectal and body temperatures; skin temperatures declined or increased only slightly. Body and rectal temperature increases corresponded with increased perception of warmth and slight thermal discomfort as exercise progressed. At all air velocities, mean thermal perception never exceeded warm and mean discomfort, greatest at 30 ft/min, was categorized at worst as uncomfortable; sensation of thermal neutrality and comfort returned rapidly after cessation of exercise. Suggestions for further elucidation of the effects of low air velocities on thermal comfort and homeostasis include larger numbers of subjects, more extensive skin temperature measurements and more rigorous analysis of the data from this study.

  15. A nocturnal decline of salivary pH associated with airway hyperresponsiveness in asthma.

    Science.gov (United States)

    Watanabe, Masanari; Sano, Hiroyuki; Tomita, Katsuyuki; Yamasaki, Akira; Kurai, Jun; Hasegawa, Yasuyuki; Igishi, Tadashi; Okazaki, Ryota; Tohda, Yuji; Burioka, Naoto; Shimizu, Eiji

    2010-08-01

    Salivary pH is associated with esophageal acid reflux and neutralization of esophageal acid. In this study, we assessed the association between nocturnal decline of salivary pH and airway hyperresponsiveness. Salivary pH was serially assessed in 9 patients with mild asthma (7 men and 2 women; mean age 33.3 years; mean %predicted FEV(1.0) 89.4%) and 10 healthy volunteers (6 men and 4 women; mean age 31.2 years) using a pH indicator tape. The buffering capacity of saliva was defined as the median effective dose (ED(50)) for acidification of saliva with 0.01 N HCl, and airway responsiveness was defined as the dose of methacholine producing a 35% fall in Grs (PD(35)-Grs). There was a significant correlation between the values obtained from the pH indicator tape and those obtained from the electrometric pH meter. Using the indicator tape for sequential monitoring, we observed a nocturnal fall (ΔpH) in salivary pH in all subjects. A significant correlation was found between airway hyperresponsiveness (PD(35)-Grs) and either ΔpH or ED(50) in mildly asthmatic patients. Vagal reflux dysfunction might contribute to nocturnal salivary pH as well as to airway hyperresponsiveness in mild asthmatics.

  16. Intermittent nocturnal hypoxia and metabolic risk in obese adolescents with obstructive sleep apnea.

    Science.gov (United States)

    Narang, Indra; McCrindle, Brian W; Manlhiot, Cedric; Lu, Zihang; Al-Saleh, Suhail; Birken, Catherine S; Hamilton, Jill

    2018-01-22

    There is conflicting data regarding the independent associations of obstructive sleep apnea (OSA) with metabolic risk in obese youth. Previous studies have not consistently addressed central adiposity, specifically elevated waist to height ratio (WHtR), which is associated with metabolic risk independent of body mass index. The objective of this study was to determine the independent effects of the obstructive apnea-hypopnea index (OAHI) and associated indices of nocturnal hypoxia on metabolic function in obese youth after adjusting for WHtR. Subjects had standardized anthropometric measurements. Fasting blood included insulin, glucose, glycated hemoglobin, alanine transferase, and aspartate transaminase. Insulin resistance was quantified with the homeostatic model assessment. Overnight polysomnography determined the OAHI and nocturnal oxygenation indices. Of the 75 recruited subjects, 23% were diagnosed with OSA. Adjusting for age, gender, and WHtR in multivariable linear regression models, a higher oxygen desaturation index was associated with a higher fasting insulin (coefficient [standard error] = 48.076 [11.255], p Intermittent nocturnal hypoxia rather than the OAHI was associated with metabolic risk in obese youth after adjusting for WHtR. Measures of abdominal adiposity such as WHtR should be considered in future studies that evaluate the impact of OSA on metabolic health.

  17. Low-temperature baseboard heaters with integrated air supply - An analytical and numerical investigation

    Energy Technology Data Exchange (ETDEWEB)

    Ploskic, Adnan; Holmberg, Sture [Fluid and Climate Technology, School of Architecture and Built Environment, KTH, Marinens vaeg 30, SE-13640 Handen, Stockholm (Sweden)

    2011-01-15

    The functioning of a hydronic baseboard heating system with integrated air supply was analyzed. The aim was to investigate thermal performance of the system when cold outdoor (ventilation) airflow was forced through the baseboard heater. The performance of the system was evaluated for different ventilation rates at typical outdoor temperatures during the Swedish winter season. Three different analytical models and Computational Fluid Dynamics (CFD) were used to predict the temperature rise of the airflow inside the baseboard heater. Good agreement between numerical (CFD) and analytical calculations was obtained. Calculations showed that it was fully possible to pre-heat the incoming airflow to the indoor temperature and to cover transmission losses, using 45 C supply water flow. The analytical calculations also showed that the airflow per supply opening in the baseboard heater needed to be limited to 7.0 l/s due to pressure losses inside the channel. At this ventilation rate, the integrated system with one air supply gave about 2.1 more heat output than a conventional baseboard heating system. CFD simulations also showed that the integrated system was capable of countering downdraught created by 2.0 m high glazed areas and a cold outdoor environment. Draught discomfort in the case with the conventional system was slightly above the recommended upper limit, but heat distribution across whole analyzed office space was uniform for both heating systems. It was concluded that low-temperature baseboard heating systems with integrated air supply can meet both international comfort requirements, and lead to energy savings in cold climates. (author)

  18. Nocturnal antihypertensive treatment in patients with type 1 diabetes with autonomic neuropathy and non-dipping of blood pressure during night time

    DEFF Research Database (Denmark)

    Hjortkær, Henrik; Jensen, Tonny; Kofoed, Klaus

    2014-01-01

    INTRODUCTION: Cardiac autonomic neuropathy (CAN) and elevated nocturnal blood pressure are independent risk factors for cardiovascular disease in patients with diabetes. Previously, associations between CAN, non-dipping of nocturnal blood pressure and coronary artery calcification have been...

  19. The Association of Pediatric Obesity With Nocturnal Non-Dipping on 24-Hour Ambulatory Blood Pressure Monitoring.

    Science.gov (United States)

    Macumber, Ian R; Weiss, Noel S; Halbach, Susan M; Hanevold, Coral D; Flynn, Joseph T

    2016-05-01

    Obesity has been linked with abnormal nocturnal dipping of blood pressure (BP) in adults, which in turn is associated with poor cardiovascular outcomes. There are few data regarding abnormal dipping status in the obese pediatric population. The goal of this study was to further describe the relationship between obesity and non-dipping status on ambulatory blood pressure monitor (ABPM) in children. We conducted a cross-sectional study using a database of patients aged 5-21 years who had undergone 24-hour ABPM at Seattle Children's Hospital from January 2008 through May 2014. Subjects were grouped by body mass index (BMI) into lean (BMI 15th-85th percentile) and obese (BMI >95th percentile) groups. Compared to lean subjects (n = 161), obese subjects (n = 247) had a prevalence ratio (PR) for non-dipping of 2.15, adjusted for race (95% confidence interval (CI) = 1.25-3.42). Increasing severity of obesity was not further associated with nocturnal non-dipping. Nocturnal non-dipping was not associated with left ventricular hypertrophy (PR = 1.01, 95% CI = 0.71-1.44). These results suggest that in children, just as in adults, obesity is related to a relatively decreased dipping in nocturnal BP. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Male broiler performance and nocturnal feeding under constant 8-h ...

    African Journals Online (AJOL)

    ... however, they still consumed more feed in the 8-h dark period than birds that had always been given 16 h illumination. Cobb and Ross genotypes responded similarly to all lighting treatments. Keywords: Photoperiod, broiler growth, nocturnal feeding. South African Journal of Animal Science Vol. 38 (3) 2008: pp. 159-165 ...