WorldWideScience

Sample records for neutron multisphere spectrometer

  1. Evaluation of response matrix of a multisphere neutron spectrometer ...

    Indian Academy of Sciences (India)

    For radiation protection, particularly inside nuclear facilities, the multisphere spectrometer is the most suitable instrument in the thermal and intermediate energy range [4]. In this work the water moderator in the aluminum sphere shell has been suggested, for the following reasons: (1) water is easily available, (2) easy to ...

  2. Some methods of neutron spectra reconstruction according to results of measurements by multispherical spectrometer

    International Nuclear Information System (INIS)

    Semenov, V.P.; Trykov, L.A.; Tyufyakov, N.D.

    1975-01-01

    MENAOT, MODSPECTRA, MODMESKO, REGUS programs designed to restore neutron spectra by results of measurements with the multi-sphere spectrometer are described. These programs are written in the ALGOL language (the TA-2M translator) for the M-220 computer. Directed selection, MODSPECTRA and regularization algorithms were used to develop these programs

  3. MAXED, a computer code for the deconvolution of multisphere neutron spectrometer data using the maximum entropy method

    International Nuclear Information System (INIS)

    Reginatto, M.; Goldhagen, P.

    1998-06-01

    The problem of analyzing data from a multisphere neutron spectrometer to infer the energy spectrum of the incident neutrons is discussed. The main features of the code MAXED, a computer program developed to apply the maximum entropy principle to the deconvolution (unfolding) of multisphere neutron spectrometer data, are described, and the use of the code is illustrated with an example. A user's guide for the code MAXED is included in an appendix. The code is available from the authors upon request

  4. Evaluation of response matrix of a multisphere neutron spectrometer ...

    Indian Academy of Sciences (India)

    Abstract. Neutron energy responses of water sphere spectrometers (WSS) to 30 MeV have been calculated by means of Monte Carlo calculations, using the computer code MCNP4C with ENDF/. B-VI.0 neutron cross-section. The calculations have been performed for 3He detector (typical SP9) placed inside 2, 3, 5, 8, ...

  5. Neutron background measurements at China Jinping underground laboratory with a Bonner multi-sphere spectrometer

    Science.gov (United States)

    Hu, Qingdong; Ma, Hao; Zeng, Zhi; Cheng, Jianping; Chen, Yunhua; He, Shengming; Li, Junli; Shen, Manbin; Wu, Shiyong; Yue, Qian; Yue, Jianfeng; Zhang, Hui

    2017-07-01

    The neutron background spectrum from thermal neutron to 20 MeV fast neutron was measured at the first experimental hall of China Jinping underground laboratory with a Bonner multi-sphere spectrometer. The measurement system was validated by a 252Cf source and inconformity was corrected. Due to micro charge discharge, the dataset was screened and background from the steel of the detectors was estimated by MC simulation. Based on genetic algorithm we obtained the energy distribution of the neutron and the total flux of neutron was (2.69±1.02) ×10-5 cm-2 s-1.

  6. Field neutron spectrometer using 3He, TEPC, and multisphere detectors

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1991-01-01

    Since the last DOE Neutron Dosimetry Workshop, there have been a number of changes in radiation protection standards proposed by national and international advisory bodies. These changes include: increasing quality factors for neutrons by a factor of two, defining quality factors as a function of lineal energy rather than linear energy transfer (see ACCRUE-40; Joint Task Group 1986), and adoption of effective dose equivalent methodologies. In order to determine the effects of these proposed changes, it is necessary to know the neutron energy spectrum in the work place. In response to the possible adoption of these proposals, the Department of Energy (DOE) initiated a program to develop practical neutron spectrometry systems for use by health physicists. One part of this program was the development of a truly portable, battery operated liquid scintillator spectrometer using proprietary electronics developed at Lawrence Livermore National Laboratory (LLNL); this instrument will be described in the following paper. The second part was the development at PNL of a simple transportable spectrometer based on commercially available electronics. This open-quotes field neutron spectrometerclose quotes described in this paper is intended to be used over a range of neutron energies extending from thermal to 20 MeV

  7. Investigation of neutron scattering for a multisphere spectrometer

    International Nuclear Information System (INIS)

    Sun, R.K.

    1990-01-01

    Count rates were measured as a function of distance from a planar concrete reflector for a set of eight Bonner-sphere detectors and four isotopic neutron sources. These data can be used to determine the contributions of scattered neutrons to the response of moderated detectors used in environments bounded by concrete. A model based on images of the original source can be developed to produce an equation that describes the data well, if the strengths of the image sources can be treated as variable parameters. Values of the parameters appearing in the equations are given based on least-squares analysis of the experimental results

  8. BUMS--Bonner sphere Unfolding Made Simple an HTML based multisphere neutron spectrometer unfolding package

    CERN Document Server

    Sweezy, J; Veinot, K

    2002-01-01

    A new multisphere neutron spectrometer unfolding package, Bonner sphere Unfolding Made Simple (BUMS) has been developed that uses an HTML interface to simplify data input and code execution for the novice and the advanced user. This new unfolding package combines the unfolding algorithms contained in other popular unfolding codes under one easy to use interface. The interface makes use of web browsing software to provide a graphical user interface to the unfolding algorithms. BUMS integrates the SPUNIT, BON, MAXIET, and SAND-II unfolding algorithms into a single package. This package also includes a library of 14 response matrices, 58 starting spectra, and 24 dose and detector responses. BUMS has several improvements beyond the addition of unfolding algorithms. It has the ability to search for the most appropriate starting spectra. Also, plots of the unfolded neutron spectra are automatically generated. The BUMS package runs via a web server and may be accessed by any computer with access to the Internet at h...

  9. Spectrometry using the PTB neutron multisphere spectrometer (NEMUS) at flight altitudes and at ground level

    CERN Document Server

    Wiegel, B; Matzke, M; Schrewe, U J; Wittstock, J

    2002-01-01

    Bonner sphere measurements are presented for flights at altitudes of up to 12 km and geomagnetic latitudes between 26 deg.N and 86 deg.N and compared with results obtained by several survey meters. As an example of the natural neutron background near sea level, results from a recent longterm measurement campaign performed at the PTB site using an extended spectrometer are presented. The dependence of neutron fluence and ambient dose equivalent on the atmospheric pressure is demonstrated.

  10. Response matrix of a multisphere neutron spectrometer with an 3 He proportional counter

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado S, G.A.

    2005-01-01

    The response matrix of a Bonner sphere spectrometer was calculated by use of the MCNP code. As thermal neutron counter, the spectrometer has a 3.2 cm-diameter 3 He-filled proportional counter which is located at the center of a set of polyethylene spheres. The response was calculated for 0, 3, 5, 6, 8, 10, 12, and 16 inches-diameter polyethylene spheres for neutrons whose energy goes from 10 -9 to 20 MeV. The response matrix was compared with a set of responses measured with several monoenergetic neutron sources. In this comparison the calculated matrix agrees with the experimental results. The matrix was also compared with the response matrix calculated for the PTB C spectrometer. Even though that calculation was carried out using a detailed model to describe the proportional counter; both matrices do agree, but small differences are observed in the bare case because of the difference in the model used during calculations. Other differences are in some spheres for 14.8 and 20 MeV neutrons, probably due to the differences in the cross sections used during both calculations. (Author) 28 refs., 1 tab., 6 figs

  11. Neutron reference spectra measurements with the Bonner multi-spheres spectrometer; Medidas de espectros de referencia de neutrons com o espectrometro de multiesferas de Bonner

    Energy Technology Data Exchange (ETDEWEB)

    Lemos Junior, Roberto Mendonca de

    2004-07-01

    This paper aims to define a procedure to use the Bonner Multisphere Spectrometer with a {sup 6}LiI(Eu) detector in order to determine of neutron spectra. It was measured {sup 238}PuBe spectra and same of reference ({sup 241}AmBe, {sup 252}Cf e {sup 252}Cf+D{sub 2}O) published in ISO 8529-1 (2001) Norm. The data were processed by a computer program (BUNKI), which presents the results in neutrons energy fluency. Each input parameter of the program was studied in order to establish their influence in the adjustment result. The environment dose equivalent rate obtained placing the detector 1 m from the {sup 241}AmBe source was 122 {+-} 4 {mu}Sv/h with 7% of uncertainty and 95% of confidence level. The procedure established in this work was tested with the {sup 238}PuBe spectrum, obtaining an environment dose equivalent rate of 286 {+-} 9 {mu}Sv/h, 8% lower than the value measured experimentally used as reference. Through this procedure will be possible to measure neutron spectra in different work places where neutrons sources are used. Knowing these spectra, it will be possible to evaluate which area monitors, are more suitable, as well as, to study better the response of individual neutron monitors, as for instance, to obtain a conversion coefficient more appropriate to the albedo dosimeter used in different work places. As the measurements need a long time to be accomplished, the work optimization is fundamental to reduce the exposing time of the Bonner spectrometer operator. For this reason, an important parameter examined in this paper was the possibility of reducing the number of spheres used during the measurement without changing the final result. Considering the radiation protection standards, this parameter has a huge importance when the measurements are performed in work places where the neutron fluency and gamma rate offer risks to the operator's health, as for instance, in nuclear centrals. Studying this parameter, it was possible to conclude that

  12. Calibration of a spectrometry multisphere system for neutron fields

    International Nuclear Information System (INIS)

    Carelli, Jorge L.; Cruzate, Juan A.; Papadopulos, Susana B.; Gregori, Beatriz N.; Ciocci Brazzano, Ligia

    2005-01-01

    In this work it is presented the calibration of the neutrons spectrometric system of the Nuclear Regulatory Authority (ARN) in the Institut de Protection et Sure te Nucleaires (Ipn), Labourite dadaist et de Recherche s en Dosimetric Extern e, Cadarache, France. The multisphere system is composed of 9 polyethylene spheres of high density, with a gaseous detector of 3 He and associate electronics. The matrix of energy response to the system neutrons was obtained applying the MCNPX code for the range of energies between thermal and 100 MeV with cross sections taken from library ENDF/B-VI. The neutron spectra of the multisphere system were obtained applying the deconvolution code LOUHI82. The relationship between the theoretical responses and the experiences obtained with the AmBe and 252 Cf sources are also presented in this work [es

  13. Multisphere system neutron spectrometry applied to dosimetry for the personnel

    International Nuclear Information System (INIS)

    Allinei, P.G.

    1992-01-01

    Neutron dosimetry is a necessity that must be dealt with in order to ensure efficient monitoring of all personnel regarding radiology safety. Dosimetric variables are difficult to measure for they are dependent on complex functions evolving with the energy of neutrons, which forces us to determine their energetic distribution. We have chosen to use the multisphere system associated to an unfolding code in order to perform neutron spectrometry, our purpose being to determine these dosimetric variables. The initial stage consists in modifying a research code, the code SOHO, in order to adapt it to our needs. The resulting new version was subsequently tested and proven successful by means of computerized simulations. Afterwards, we used reference dosimetric and spectral beams to confirm the position results previously obtained. At the time of this test, the code SOHO yielded results coherent with the theoretical values, and even allowed the quantity of radiation diffused by the laboratory structures to be estimated. The final part of this study consists in applying the previously perfected technique to authentic situations. The results thus obtained are compared to those obtained by conventional methods in order to reveal the interest of neutron spectrometry used for dosimetry of the personnel

  14. FRUIT: An operational tool for multisphere neutron spectrometry in workplaces

    Science.gov (United States)

    Bedogni, Roberto; Domingo, Carles; Esposito, Adolfo; Fernández, Francisco

    2007-10-01

    FRUIT (Frascati Unfolding Interactive Tool) is an unfolding code for Bonner sphere spectrometers (BSS) developed, under the Labview environment, at the INFN-Frascati National Laboratory. It models a generic neutron spectrum as the superposition of up to four components (thermal, epithermal, fast and high energy), fully defined by up to seven positive parameters. Different physical models are available to unfold the sphere counts, covering the majority of the neutron spectra encountered in workplaces. The iterative algorithm uses Monte Carlo methods to vary the parameters and derive the final spectrum as limit of a succession of spectra fulfilling the established convergence criteria. Uncertainties on the final results are evaluated taking into consideration the different sources of uncertainty affecting the input data. Relevant features of FRUIT are (1) a high level of interactivity, allowing the user to follow the convergence process, (2) the possibility to modify the convergence tolerances during the run, allowing a rapid achievement of meaningful solutions and (3) the reduced dependence of the results from the initial hypothesis. This provides a useful instrument for spectrometric measurements in workplaces, where detailed a priori information is usually unavailable. This paper describes the characteristics of the code and presents the results of performance tests over a significant variety of reference and workplace neutron spectra ranging from thermal up to hundreds MeV neutrons.

  15. FRUIT: An operational tool for multisphere neutron spectrometry in workplaces

    International Nuclear Information System (INIS)

    Bedogni, Roberto; Domingo, Carles; Esposito, Adolfo; Fernandez, Francisco

    2007-01-01

    FRUIT (Frascati Unfolding Interactive Tool) is an unfolding code for Bonner sphere spectrometers (BSS) developed, under the Labview environment, at the INFN-Frascati National Laboratory. It models a generic neutron spectrum as the superposition of up to four components (thermal, epithermal, fast and high energy), fully defined by up to seven positive parameters. Different physical models are available to unfold the sphere counts, covering the majority of the neutron spectra encountered in workplaces. The iterative algorithm uses Monte Carlo methods to vary the parameters and derive the final spectrum as limit of a succession of spectra fulfilling the established convergence criteria. Uncertainties on the final results are evaluated taking into consideration the different sources of uncertainty affecting the input data. Relevant features of FRUIT are (1) a high level of interactivity, allowing the user to follow the convergence process, (2) the possibility to modify the convergence tolerances during the run, allowing a rapid achievement of meaningful solutions and (3) the reduced dependence of the results from the initial hypothesis. This provides a useful instrument for spectrometric measurements in workplaces, where detailed a priori information is usually unavailable. This paper describes the characteristics of the code and presents the results of performance tests over a significant variety of reference and workplace neutron spectra ranging from thermal up to hundreds MeV neutrons

  16. Evaluation of response matrix of a multisphere neutron spectrometer ...

    Indian Academy of Sciences (India)

    The calculations have been performed for 3He detector (typical SP9) placed inside 2, 3, 5, 8, 12 and 18-inch diameter moderating spheres composed of water in aluminum shell. ... Hashem Miri Hakimabad1. Physics Department, School of Sciences, Ferdowsi University of Mashhad, Mashhad, Postal code: 91775-1436, Iran ...

  17. Measurement of the neutron spectrum in a room with an accelerator Varian 2300C/D Linac using the Bonner multisphere spectrometer; Medicao do espectro de neutrons em uma sala com um acelerador Varian 2300C/D Linav usando o espectrometro de multiesferas de Bonner

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcante, D.B.S., E-mail: cavalcante@ird.gov.b [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica; Fonseca, E.S. da, E-mail: evaldo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Lemos Junior, R.M. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil); Batista, D.V.S. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The generated neutron field varies considerably and depends on the beam energy, on the shielding of the accelerator, on the filters for beam homogeneity, and also on the mobile collimators and geometry of irradiation. The estimation of the component relative to the photoneutrons has practical interest for evaluation of the radiological risks for the workers and for the patient as well. Due to the high frequency magnetic field, and to the photon abundance resulting of the escape and scattering at treatment room, those measurements present some difficulties. Measurements of the neutron fields can be made with a Bonner spectrometer. Those system was calibrated with referred neutron standard sources and used for make measurements on a spot of the room where a Variant 2300C/D Linac is installed. The unfolding process used the BUNKI computer code for determination of the neutron spectra at the measurement spot

  18. Prototype Neutron Energy Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Mitchell, Sanjoy Mukhopadhyay, Richard Maurer, Ronald Wolff

    2010-06-16

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  19. Neutron range spectrometer

    Science.gov (United States)

    Manglos, Stephen H.

    1989-06-06

    A neutron range spectrometer and method for determining the neutron energy spectrum of a neutron emitting source are disclosed. Neutrons from the source are collimnated along a collimation axis and a position sensitive neutron counter is disposed in the path of the collimated neutron beam. The counter determines positions along the collimation axis of interactions between the neutrons in the neutron beam and a neutron-absorbing material in the counter. From the interaction positions, a computer analyzes the data and determines the neutron energy spectrum of the neutron beam. The counter is preferably shielded and a suitable neutron-absorbing material is He-3. The computer solves the following equation in the analysis: ##EQU1## where: N(x).DELTA.x=the number of neutron interactions measured between a position x and x+.DELTA.x, A.sub.i (E.sub.i).DELTA.E.sub.i =the number of incident neutrons with energy between E.sub.i and E.sub.i +.DELTA.E.sub.i, and C=C(E.sub.i)=N .sigma.(E.sub.i) where N=the number density of absorbing atoms in the position sensitive counter means and .sigma. (E.sub.i)=the average cross section of the absorbing interaction between E.sub.i and E.sub.i +.DELTA.E.sub.i.

  20. FAST NEUTRON SPECTROMETER

    Science.gov (United States)

    Davis, F.J.; Hurst, G.S.; Reinhardt, P.W.

    1959-08-18

    An improved proton recoil spectrometer for determining the energy spectrum of a fast neutron beam is described. Instead of discriminating against and thereby"throwing away" the many recoil protons other than those traveling parallel to the neutron beam axis as do conventional spectrometers, this device utilizes protons scattered over a very wide solid angle. An ovoidal gas-filled recoil chamber is coated on the inside with a scintillator. The ovoidal shape of the sensitive portion of the wall defining the chamber conforms to the envelope of the range of the proton recoils from the radiator disposed within the chamber. A photomultiplier monitors the output of the scintillator, and a counter counts the pulses caused by protons of energy just sufficient to reach the scintillator.

  1. Spectrometers for compact neutron sources

    Science.gov (United States)

    Voigt, J.; Böhm, S.; Dabruck, J. P.; Rücker, U.; Gutberlet, T.; Brückel, T.

    2018-03-01

    We discuss the potential for neutron spectrometers at novel accelerator driven compact neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear reactions, which enable cryogenic moderators in very close proximity to the target and neutron optics at comparably short distances from the moderator compared to existing sources. While the first effect aims at increasing the phase space density of a moderator, the second allows the extraction of a large phase space volume, which is typically requested for spectrometer applications. We find that competitive spectrometers can be realized if (a) the neutron production rate can be synchronized with the experiment repetition rate and (b) the emission characteristics of the moderator can be matched to the phase space requirements of the experiment. MCNP simulations for protons or deuterons on a Beryllium target with a suitable target/moderator design yield a source brightness, from which we calculate the sample fluxes by phase space considerations for different types of spectrometers. These match closely the figures of todays spectrometers at medium flux sources. Hence we conclude that compact neutron sources might be a viable option for next generation neutron sources.

  2. Portable neutron spectrometer and dosimeter

    Science.gov (United States)

    Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  3. Advanced Neutron Spectrometer

    Science.gov (United States)

    Christl, Mark; Dobson, Chris; Norwood, Joseph; Kayatin, Matthew; Apple, Jeff; Gibson, Brian; Dietz, Kurt; Benson, Carl; Smith, Dennis; Howard, David; hide

    2013-01-01

    Energetic neutron measurements remain a challenge for space science investigations and radiation monitoring for human exploration beyond LEO. We are investigating a new composite scintillator design that uses Li6 glass scintillator embedded in a PVT block. A comparison between Li6 and Boron 10 loaded scintillators are being studied to assess the advantages and shortcomings of these two techniques. We present the details of the new Li6 design and results from the comparison of the B10 and Li6 techniques during exposures in a mixed radiation field produced by high energy protons interacting in a target material.

  4. Superheated drop as a neutron spectrometer

    Science.gov (United States)

    Das, Mala; Chatterjee, B. K.; Roy, B.; Roy, S. C.

    2000-09-01

    Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. The application of superheated drops in neutron research especially in neutron dosimetry is a subject of intense research for quite sometime. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This property of superheated liquid makes it possible to use it as a neutron spectrometer. Neutron detection efficiency of superheated drops made of R12 exposed to Am-Be neutron source has been measured over a wide range of temperature -17-60°C and the results have been utilised to construct the energy spectrum of the neutron source. This paper demonstrates that a suitable neutron spectrometer may be constructed by using a single liquid and varying the temperature of the liquid suitably at a closer grid.

  5. Superheated drop as a neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Das, Mala; Chatterjee, B.K.; Roy, B. E-mail: biva@bosemain.boseinst.ernet.in; Roy, S.C

    2000-09-21

    Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. The application of superheated drops in neutron research especially in neutron dosimetry is a subject of intense research for quite sometime. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This property of superheated liquid makes it possible to use it as a neutron spectrometer. Neutron detection efficiency of superheated drops made of R12 exposed to Am-Be neutron source has been measured over a wide range of temperature -17-60 deg. C and the results have been utilised to construct the energy spectrum of the neutron source. This paper demonstrates that a suitable neutron spectrometer may be constructed by using a single liquid and varying the temperature of the liquid suitably at a closer grid.

  6. Study of neutron spectrometers for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  7. Neutron spectrometer for improved SNM search.

    Energy Technology Data Exchange (ETDEWEB)

    Vance, Andrew L.; Aigeldinger, Georg

    2007-03-01

    With the exception of large laboratory devices with very low sensitivities, a neutron spectrometer have not been built for fission neutrons such as those emitted by special nuclear materials (SNM). The goal of this work was to use a technique known as Capture Gated Neutron Spectrometry to develop a solid-state device with this functionality. This required modifications to trans-stilbene, a known solid-state scintillator. To provide a neutron capture signal we added lithium to this material. This unique triggering signal allowed identification of neutrons that lose all of their energy in the detector, eliminating uncertainties that arise due to partial energy depositions. We successfully implemented a capture gated neutron spectrometer and were able to distinguish an SNM like fission spectrum from a spectrum stemming from a benign neutron source.

  8. A digital control system for neutron spectrometers

    DEFF Research Database (Denmark)

    Hansen, Knud Bent; Skaarup, Per

    1968-01-01

    A description is given of the principles of a digital system used to control neutron spectrometers. The system is composed of independent functional units with the control programme stored on punched paper tape or in a computer.......A description is given of the principles of a digital system used to control neutron spectrometers. The system is composed of independent functional units with the control programme stored on punched paper tape or in a computer....

  9. Design of radial neutron spectrometer for ITER

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Kasai, Satoshi; Iguchi, Tetsuo; Ebisawa, Katsuyuki; Kita, Yoshio.

    1996-09-01

    We designed the radial neutron spectrometer using a new type DT neutron spectrometer base on a recoil proton counter-telescope technique aiming ion temperature measurement for ITER. The neutron spectrometer will be installed on the well-collimated neutron beam line. A large-area recoil proton emitter is placed in parallel to the incident neutron beam and a micro-channel collimating plates are inserted between the radiator and the recoil proton detectors away from the neutron beam in order to limit the scattering angle of protons to the proton detectors. Here a very thin polyethylene film and a silicon surface barrier detector are employed as the radiator and proton detector, respectively. The energy resolution and detection efficiency are estimated to be 2.5% and 1x10 -5 counts/(n/cm 2 ), respectively for DT neutron through Monte Carlo calculations. Five units of the spectrometers will be installed just out side the bio-shield and consist a fun array using penetrations inside the bio-shield and a pre-collimator in the horizontal port. The life time of the proton detectors is estimated to be about one year in the Basic Performance Phase of ITER by neutron transport calculations using MCNP Monte Carlo code. The necessary R and D items and the design work were identified. (author)

  10. An efficient gravitational spectrometer for ultracold neutrons

    International Nuclear Information System (INIS)

    Geltenbort, P.; Goeltl, L.; Henneck, R.; Horras, M.; Kirch, K.; Knecht, A.; Lauss, B.; Meier, M.; Straumann, U.; Zsigmond, G.

    2010-01-01

    We report on the design and construction of an efficient gravitational spectrometer for ultracold neutrons. The spectrometer is suited to experiments that can greatly profit from knowledge of the neutron energy spectrum without losing available statistics, such as many of the current precision experiments that use ultracold neutrons. The description of the apparatus is complemented by the results of the first test measurements which served as a proof of principle and showed its capability of discriminating between different UCN energy ranges. The measurements showed the expected behavior and are in qualitative agreement with Monte Carlo simulations.

  11. An efficient gravitational spectrometer for ultracold neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Geltenbort, P. [Institut Laue-Langevin, Grenoble (France); Goeltl, L. [Paul Scherrer Institut, PSI, Villigen (Switzerland); ETH Zuerich, Zuerich (Switzerland); Henneck, R. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Horras, M. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Excellence Cluster ' Universe' , Technische Universitaet Muenchen, Garching (Germany); Kirch, K., E-mail: klaus.kirch@psi.c [Paul Scherrer Institut, PSI, Villigen (Switzerland); ETH Zuerich, Zuerich (Switzerland); Knecht, A., E-mail: a.knecht@psi.c [Paul Scherrer Institut, PSI, Villigen (Switzerland); University of Zuerich, Zuerich (Switzerland); ETH Zuerich, Zuerich (Switzerland); Lauss, B.; Meier, M. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Straumann, U. [University of Zuerich, Zuerich (Switzerland); Zsigmond, G. [Paul Scherrer Institut, PSI, Villigen (Switzerland)

    2010-12-01

    We report on the design and construction of an efficient gravitational spectrometer for ultracold neutrons. The spectrometer is suited to experiments that can greatly profit from knowledge of the neutron energy spectrum without losing available statistics, such as many of the current precision experiments that use ultracold neutrons. The description of the apparatus is complemented by the results of the first test measurements which served as a proof of principle and showed its capability of discriminating between different UCN energy ranges. The measurements showed the expected behavior and are in qualitative agreement with Monte Carlo simulations.

  12. J-NSE: Neutron spin echo spectrometer

    Directory of Open Access Journals (Sweden)

    Olaf Holderer

    2015-08-01

    Full Text Available Neutron Spin-Echo (NSE spectroscopy is well known as the only neutron scattering technique that achieves energy resolution of several neV. By using the spin precession of polarized neutrons in magnetic field one can measure tiny velocity changes of the individual neutron during the scattering process. Contrary to other inelastic neutron scattering techniques, NSE measures the intermediate scattering function S(Q,t in reciprocal space and time directly. The Neutron Spin-Echo spectrometer J-NSE, operated by JCNS, Forschungszentrum Jülich at the Heinz Maier-Leibnitz Zentrum (MLZ in Garching, covers a time range (2 ps to 200 ns on length scales accessible by small angle scattering technique. Along with conventional NSE spectroscopy that allows bulk measurements in transmission mode, J-NSE offers a new possibility - gracing incidence spin echo spectroscopy (GINSENS, developed to be used as "push-button" option in order to resolve the depth dependent near surface dynamics.

  13. Some characteristics of a miniature neutron spectrometer

    International Nuclear Information System (INIS)

    Sekimoto, H.; Oishi, K.; Hojo, K.; Hojo, T.

    1984-01-01

    Some characteristics of an NE213 miniature spherical spectrometer for in-assembly fast-neutron spectrometry were measured. As the bubbling time changed, the pulse-height did not change appreciably, but the n-γ discrimination characteristics changed considerably. As the count rate changed, the pulse-height did not change appreciably, and the change of the n-γ discrimination characteristics was acceptable. The neutron response function was measured to be almost isotropic except for the backward direction. (orig.)

  14. Full-absorption scintillation spectrometer for neutrons

    International Nuclear Information System (INIS)

    Dzhelepov, V.P.; Filchenkov, V.V.; Konin, A.D.; Rudenko, A.I.; Solovieva, G.M.; Zinov, V.G.

    1988-01-01

    A full-absorption scintillation spectrometer for neutrons (volume of scintillator = 24 l) has been developed and employed in investigations of muon catalysed processes. Its application allows: (a) Considerably increasing the rate of accummulation of events; (b) efficiently using muon catalysis multiplicity for fuller and more reliable determination of its parameters; (c) significantly reducing uncertainty in the calculated and experimentally found values of neutron detection efficiency. The device combines good spectrometric properties for neutron energies E n = 1-6 MeV and reliable n-γ separation (the degree of separation for a Pu-Be source 3 starting from an electron energy of 50 keV). (orig.)

  15. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  16. Prismatic analyzer concept for neutron spectrometers

    DEFF Research Database (Denmark)

    Birk, Jonas O.; Marko, M.; Freeman, P.G.

    2014-01-01

    Developments in modern neutron spectroscopy have led to typical sample sizes decreasing from few cm to several mm in diameter samples. We demonstrate how small samples together with the right choice of analyser and detector components makes distance collimation an important concept in crystal...... analyser spectrometers. We further show that this opens new possibilities where neutrons with different energies are reflected by the same analyser but counted in different detectors, thus improving both energy resolution and total count rate compared to conventional spectrometers. The technique can...... inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor...

  17. New spectrometers for diffuse scattering of neutrons

    International Nuclear Information System (INIS)

    Just, W.; Schmatz, W.; Bauer, G.

    1975-01-01

    The study of defects in solids can be complemented in many cases by the diffuse scattering of X-rays, neutrons or electrons to draw information about size, symmetry and position of defects. Since defect concentrations are usually very low in order to avoid interactions, the intensity problem is of major concern as well as the distinction between the interesting signal and other sources of scattering. Two neutron spectrometers are described which were specially designed to tackle these problems, one of them operating in Juelich, the other one on the HFR in Grenoble. The second one, also offering the possibility of employing polarized neutrons, is specially suited to the study of diffuse magnetic scattering

  18. Neutron and gamma-ray spectra of 239PuBe and 241AmBe

    International Nuclear Information System (INIS)

    Vega-Carrillo, H.R.; Manzanares-Acuna, Eduardo; Becerra-Ferreiro, A.M.; Carrillo-Nunez, Aureliano

    2002-01-01

    Neutron and gamma-ray spectra of 239 PuBe and 241 AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a 6 LiI(Eu) scintillator. The 239 PuBe neutron spectrum was measured in an open environment, while the 241 AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the 241 AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity

  19. Fast neutron spectrometer with pulse shape discrimination

    International Nuclear Information System (INIS)

    Verbitsky, S.S.

    1978-01-01

    A fast neutron spectrometer with a stilbene single crystal designed to operate at high pulsed count rate has been described. Making use of identification and rejection of events, accompanied by pile-up, allowed to increase permissible count rates by an order of magnitude. The results of energy dependence of signal amplitude and shape relative anisotropy in stilbene in the range 4-10 and 2-8 MeV respectively have been presented. Taking into account anisotropy of the detector-scintillation properties allowed to improve particle discrimination. (Auth.)

  20. Microprocessor-controlled portable neutron spectrometer

    International Nuclear Information System (INIS)

    Hunt, G.F.; Kaifer, R.C.; Slaughter, D.R.; Strout, R.E. II; Rueppel, D.W.

    1979-01-01

    A neutron spectrometer that acquires and unfolds data in the field has been developed for use in the energy range from 1 to 20 MeV. The system includes an NE213 organic scintillation detector, automatic gain stabilization, automatically stabilized pulseshape discrimination, an LSl-11 microprocessor for control and data reduction, and a multichannel analyzer for data acquisition. The system, with the exception of the multichannel analyzer, is mounted in a suitcase 47 by 66 by 23.5 cm. The mass is 23.5 kg

  1. Measuring neutron spectra in radiotherapy using the nested neutron spectrometer.

    Science.gov (United States)

    Maglieri, Robert; Licea, Angel; Evans, Michael; Seuntjens, Jan; Kildea, John

    2015-11-01

    Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation-maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors' measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. The NNS may be used to reliably measure the neutron

  2. Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Maglieri, Robert, E-mail: robert.maglieri@mail.mcgill.ca; Evans, Michael; Seuntjens, Jan; Kildea, John [Medical Physics Unit, McGill University, Montreal, Quebec H4A 3J1 (Canada); Licea, Angel [Canadian Nuclear Safety Commission, Ottawa, Ontario K1P 5S9 (Canada)

    2015-11-15

    Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may

  3. Neutron guide shielding for the BIFROST spectrometer at ESS

    DEFF Research Database (Denmark)

    Mantulnikovs, K.; Bertelsen, M.; Cooper-Jensen, C.P.

    2016-01-01

    We report on the study of fast-neutron background for the BIFROST spectrometer at ESS. We investigate the effect of background radiation induced by the interaction of fast neutrons from the source with the material of the neutron guide and devise a reasonable fast, thermal/cold neutron shielding...

  4. Polarized neutron scattering on HYSPEC: the HYbrid SPECtrometer at SNS

    Energy Technology Data Exchange (ETDEWEB)

    Zaliznyak, Igor [Brookhaven National Laboratory (BNL); Savici, Andrei T [ORNL; Garlea, Vasile O [ORNL; Winn, Barry L [ORNL; Schneelock, John [Brookhaven National Laboratory (BNL); Tranquada, John M. [Brookhaven National Laboratory (BNL); Gu, G. D. [Brookhaven National Laboratory (BNL); Wang, Aifeng [Brookhaven National Laboratory (BNL); Petrovic, C [Brookhaven National Laboratory (BNL)

    2017-01-01

    We describe some of the first polarized neutron scattering measurements performed at HYSPEC spectrometer at the Spallation Neutron Source, Oak Ridge National Laboratory. We discuss details of the instrument setup and the experimental procedures in the mode with the full polarization analysis. Examples of the polarized neutron diffraction and the polarized inelastic neutron data obtained on single crystal samples are presented.

  5. MESSENGER E/V/H GRNS 4 NEUTRON SPECTROMETER DDR V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER Neutron Spectrometer (NS) 'derived' data records (DDRs). The NS experiment is a neutron spectrometer...

  6. MESSENGER E/V/H GRNS 4 NEUTRON SPECTROMETER DDR V2.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER Neutron Spectrometer (NS) 'derived' data records (DDRs). The NS experiment is a neutron spectrometer...

  7. MESSENGER E/V/H GRNS 3 NEUTRON SPECTROMETER CDR V2.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER Neutron Spectrometer (NS) calibrated data records (CDRs). The NS experiment is a neutron spectrometer...

  8. MESSENGER E/V/H GRNS 3 NEUTRON SPECTROMETER CDR V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER Neutron Spectrometer (NS) calibrated data records (CDRs). The NS experiment is a neutron spectrometer...

  9. Determination of the spectral neutron fluence rate onboard aircraft by means of a passive Bonner sphere spectrometer

    International Nuclear Information System (INIS)

    Hajek, M.; Berger, T.; Vana, N.

    2002-01-01

    Full text: Initiated by the recommendations of the International Commission on Radiological Protection (ICRP), the exposure of aircraft crew to cosmic radiation has been included as occupational exposure in the European Council directive 96/29/Euratom. Of the complex mixed radiation field at aviation altitudes the neutron component can contribute more than 50 % to the biologically relevant dose equivalent and is, therefore, of great importance. Applying the multi-sphere moderation technique, Bonner sphere spectrometers (BSS) are currently the only instruments providing a sufficient response over several orders of energy up to GeV. As could be demonstrated by extensive experiments in a variety of reference radiation fields, charged particles significantly contribute to the count rate of active detectors such as 6 LiI-scintillators or 3 He-proportional counters, which are commonly employed as thermal neutron detectors inside the spheres. This limitation can be overcome with a passive BSS, which uses different types of thermoluminescent dosemeters (TLDs): the thermal neutron-sensitive TLD-600 ( 6 LiF) and the thermal neutron-insensitive TLD-700 ( 7 LiF). Assuming identical responses of both types for the other radiation components, subtraction of the TLD-700 signal from the TLD-600 signal reveals a net signal from thermal neutrons. The passive BSS was calibrated in the CERN-EU High-Energy Reference Field (CERF), which provides a neutron spectrum in reasonable agreement with that occurring at aviation altitudes. Measurements onboard aircraft were performed during a series of eight north-bound flights originating from Cologne. The results are compared with calculations of the neutron spectrum by means of the well-established Monte Carlo code FLUKA. (author)

  10. Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

    Science.gov (United States)

    Gaganov, V. V.; Usenko, P. L.; Kryzhanovskaja, M. A.

    2017-12-01

    Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

  11. Development of triple axis neutron spectrometer (Paper No. 24)

    International Nuclear Information System (INIS)

    Pal, B.C.; Wadhwa, N.R.; Goveas, S.H.

    1987-02-01

    The triple axis neutron spectrometers are the basic instruments intended for use with neutron beams from reactors. Various types of spectrometers, each devoted to different kinds of measurement can be designed and manufactured, once a prototype having all the attributes of a versatile instrument is designed and developed. With the view to achieving self reliance in this field, Central Workshops of Bhabha Atomic Research Centre (BARC), Bombay designed and developed a prototype of triple axis spectrometer meeting the specifications prepared by Nuclear Physics Division of BARC . This spectrometer, with a moving wedge system was successfully manufactured and installed at 'DHRUVA'. Another version of this spectrometer, called the 'Polarised Neutron Spectrometer' was also built and exported to South Korea and installed at Korea Advanced Energy Research Institute, Seoul. This paper deals with basic concept, development of design, engineering of mechanical assemblies, the manufacturing approach and problems encountered during manufacture. (author). 3 figs

  12. A high performance neutron spectrometer for planetary hydrogen measurement

    Science.gov (United States)

    Naito, Masayuki; Hasebe, Nobuyuki; Nagaoka, Hiroshi; Ishii, Junya; Aoki, Daisuke; Shibamura, Eido; Kim, Kyeong J.; Matias-Lopes, José A.; Martínez-Frías, Jesús

    2017-08-01

    The elemental composition and its distribution on planetary surface provide important constraints on the origin and evolution of the planetary body. The nuclear spectrometer consisting of a neutron spectrometer and a gamma-ray spectrometer obtains elemental compositions by remote sensing. Especially, the neutron spectrometer is able to determine the hydrogen concentration, a piece of information that plays an important role in thermal history of the planets. In this work, numerical and experimental studies on the neutron spectrometer for micro-satellite application were conducted. It is found that background count rate of neutron produced from micro-satellite is very small, which enables to obtain successful results in short time observation. The neutron spectrometer combining a lithium-6 glass scintillator with a boron loaded plastic scintillator was used to be able to detect neutrons in different energy ranges. It was experimentally confirmed that the neutron signals from these scintillators were successfully discriminated by the difference of scintillation decay time between two detectors. The measurement of neutron count rates of two scintillators is found to determine hydrogen concentration on the planetary surfaces in the future missions.

  13. MONSTER: a TOF Spectrometer for β-delayed Neutron Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Martínez, T., E-mail: trino.martinez@ciemat.es [Centro de Investigaciones Energéticas, MedioAmbientales y Tecnológicas, CIEMAT, Madrid 28040 (Spain); Cano-Ott, D.; Castilla, J.; Garcia, A.R.; Marin, J.; Martinez, G.; Mendoza, E.; Santos, C.; Tera, F.J.; Villamarin, D. [Centro de Investigaciones Energéticas, MedioAmbientales y Tecnológicas, CIEMAT, Madrid 28040 (Spain); Agramunt, J.; Algora, A.; Domingo, C.; Jordan, M.D.; Rubio, B.; Taín, J.L. [Instituto de Física Corpuscular, CSIC-Universidad de Valencia (Spain); Bhattacharya, C.; Banerjee, K.; Bhattacharya, S.; Roy, P. [Variable Energy Cyclotron Centre (VECC), Kolkata (India); and others

    2014-06-15

    β-delayed neutron (DN) data, including emission probabilities, Pn, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

  14. MONSTER: a TOF Spectrometer for beta-delayed Neutron Spetroscopy

    CERN Document Server

    Martinez, T; Castilla, J; Garcia, A R; Marin, J; Martinez, G; Mendoza, E; Santos, C; Tera, F; Jordan, M D; Rubio, B; Tain, J L; Bhattacharya, C; Banerjee, K; Bhattacharya, S; Roy, P; Meena, J K; Kundu, S; Mukherjee, G; Ghosh, T K; Rana, T K; Pandey, R; Saxena, A; Behera, B; Penttila, H; Jokinen, A; Rinta-Antila, S; Guerrero, C; Ovejero, M C; Villamarin, D; Agramunt, J; Algora, A

    2014-01-01

    Beta-delayed neutron (DN) data, including emission probabilities, P-n, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

  15. LP MOON NEUTRON SPECTROMETER 3 RDR V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Neutron Spectrometer data acquired by Lunar Prospector have been reduced to four maps, which can be interpreted in terms of elemental composition of the lunar...

  16. An improved computer controlled triple-axis neutron spectrometer

    International Nuclear Information System (INIS)

    Cooper, M.J.; Hall, J.W.; Hutchings, M.T.

    1975-07-01

    A description is given of the computer-controlled triple-axis neutron spectrometer installed at the PLUTO reactor at Harwell. The reasons for an nature of recent major improvements are discussed. Following a general description of the spectrometer, details are then given of the new computerised control system, including the functions of the various programs which are now available to the user. (author)

  17. Design of a transportable high efficiency fast neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Roecker, C., E-mail: calebroecker@berkeley.edu [Department of Nuclear Engineering, University of California at Berkeley, CA 94720 (United States); Bernstein, A.; Bowden, N.S. [Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Cabrera-Palmer, B. [Radiation and Nuclear Detection Systems, Sandia National Laboratories, Livermore, CA 94550 (United States); Dazeley, S. [Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Gerling, M.; Marleau, P.; Sweany, M.D. [Radiation and Nuclear Detection Systems, Sandia National Laboratories, Livermore, CA 94550 (United States); Vetter, K. [Department of Nuclear Engineering, University of California at Berkeley, CA 94720 (United States); Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2016-08-01

    A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV and a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm{sup 2} rising to 5000 cm{sup 2}. For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm{sup 2} and 2500 cm{sup 2}. The multiplicity mode was found to be sensitive to the incident neutron angular distribution.

  18. The neutron spin-echo spectrometer: a new high resolution technique in neutron scattering

    International Nuclear Information System (INIS)

    Nicholson, L.K.

    1981-01-01

    The neutron spin-echo (NSE) spectrometer provides the highest energy resolution available in neutron scattering experiments. The article describes the principles behind the first NSE spectrometer (at the Institute Laue-Langevin, Grenoble, France) and, as an example of one of its applications, some recent results on polymer chain dynamics are presented. (author)

  19. 4D space access neutron spectrometer 4SEASONS (SIKI)

    International Nuclear Information System (INIS)

    Kajimoto, Ryoichi; Nakamura, Mitsutaka

    2010-01-01

    The 4D Space Access Neutron Spectrometer (4SEASONS) is a high-intensity Fermi-chopper spectrometer. It is intended to provide high counting rate for thermal neutrons with medium resolution (ΔE/E i -6% at E=0) to efficiently collect weak inelastic signals from novel spin and lattice dynamics especially in high-T c superconductors and related materials. To achieve this goal, the spectrometer equips advanced instrumental design such as an elliptic-shaped converging neutron guide coated with high-Q c (m=3-4) supermirror, and long-length (2.5 m) 3 He position sensitive detectors (PSDs) arranged cylindrically inside the vacuum scattering chamber. Furthermore, the spectrometer is ready for multi-incident-energy measurements by the repetition rate multiplication method, which greatly improves the measurement efficiency. (author)

  20. Superheated drop as a neutron spectrometer

    OpenAIRE

    Das, Mala; Chatterjee, B. K.; Roy, B.; Roy, S. C.

    2000-01-01

    Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This property of superheated liquids are being utilised to develope the neutron spectromer. A new principle of neutron spectrometry using Superheated liquid are developed and the developed principle has been tested by Am-Be neutron source.

  1. Time-of-flight neutron spectrometer for JT-60U

    International Nuclear Information System (INIS)

    Shibata, Y.; Iguchi, T.; Uritani, Akira; Kawarabayashi, Jun; Hoek, Magnus; Nishitani, T.; Morioka, A.

    2001-01-01

    We have developed a 2.45 MeV neutron Double Crystal Time-of-Flight (DC-TOF) spectrometer for Deuterium plasmas in JT-60U. The DC-TOF neutron spectrometer consists of two fast plastic scintillators (BC-408 made by Bicron, 50 cm 2 and 1800 cm 2 , thickness 2 cm), located on constant TOF spheres. The constant TOF spheres have a radius of 1 m which gives a neutron flight length of 1.64 m and a TOF of 92 ns for 2.45 MeV neutrons. The calculated spectrometer efficiency and resolution are 2.8x10 -2 cm 2 and 100 keV, respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer has been installed in the basement of JT-60U, 10 m away from the plasma center with vertical line-of-sight. Neutron energy spectra have been obtained when the neutron yield from the plasma is ∼10 15 neutrons/s. (author)

  2. A neutron spectrometer for studying giant resonances with (p,n) reactions in inverse kinematics

    NARCIS (Netherlands)

    Stuhl, L.; Krasznahorkay, A.; Csatlos, M.; Algora, A.; Gulyas, J.; Kalinka, G.; Timar, J.; Kalantar-Nayestanaki, N.; Rigollet, C.; Bagchi, S.; Najafi, M. A.

    2014-01-01

    A neutron spectrometer, the European Low-Energy Neutron Spectrometer (ELENS), has been constructed to study exotic nuclei in inverse-kinematics experiments. The spectrometer, which consists of plastic scintillator bars, can be operated in the neutron energy range of 100 keV-10 MeV. The neutron

  3. Three-axis neutron spectrometer on the IWW-2 reactor

    International Nuclear Information System (INIS)

    Bobrovskij, V.I.; Goshchitskij, B.N.; Mirmel'shtejn, A.V.; Mikha lov, Yu.N.; Ponosov, Yu.S.

    1977-01-01

    A three-axis neutron spectrometer providing for the possibility to change smoothly the neutron scattering angle in the course of measurement was manufactured for studying the dynamics (frequencies and life time of phonons) of a crystalline lattice. This permits to use methods of constant energy and momentum transfer at fixed incident wave length in the scattering angle range of up to 100 deg. Major attention was given to such a substantial characteristic of the three-axis spectrometer as the spectrometer resolution function, which was determined experimentally and theoretically. A knowledge of that function permitted to make a sufficiently exact account of focusing effects when measuring neutron resonance, and to determine the instrumental widths of the resonances observed. A crystal incorporating a helium and nitrogen vessel was made for measurements in the 300-20 K range. A system of protective copper shields surrounding the helium vessel and a sample permits to operate without refilling helium for about 30 hr

  4. Development of a double scintillator fast neutron spectrometer

    International Nuclear Information System (INIS)

    Shirakata, Keisho; Iijima, Tsutomu; Cho, Mann.

    1976-03-01

    A double scintillator fast neutron spectrometer based on the time-of-flight measurement between two plastic scintillators has been developed for spectrum measurement in FCA cores and other fast systems. Neutrons extracted from a fast system are scattered by the 1st scintillator and the 2nd scintillator detects the scattered neutrons. By measuring the time-of-flight between the two scintillators, the neutron spectrum is determined. The method is essentially differential, and a complicated unfolding process is not required. The results of its application indicate excellence of the method over other methods in the energy range above several hundreds keV. Design and characteristics of the spectrometer, application, analysis of the measured data are described in detail. (auth.)

  5. An Advanced Neutron Spectrometer for Future Manned Exploration Missions

    Science.gov (United States)

    Christl, Mark; Apple, Jeffrey A.; Cox, Mark D.; Dietz, Kurtis L.; Dobson, Christopher C.; Gibson, Brian F.; Howard, David E.; Jackson, Amanda C.; Kayatin, Mathew J.; Kuznetsov, Evgeny N.; hide

    2014-01-01

    An Advanced Neutron Spectrometer (ANS) is being developed to support future manned exploration missions. This new instrument uses a refined gate and capture technique that significantly improves the identification of neutrons in mixed radiation fields found in spacecraft, habitats and on planetary surfaces. The new instrument is a composite scintillator comprised of PVT loaded with litium-6 glass scintillators. We will describe the detection concept and show preliminary results from laboratory tests and exposures at particle accelerators

  6. Time recording unit for a neutron time of flight spectrometer

    International Nuclear Information System (INIS)

    Puranik, Praful; Ajit Kiran, S.; Chandak, R.M.; Poudel, S.K.; Mukhopadhyay, R.

    2011-01-01

    Here the architecture and design of Time Recording Unit for a Neutron Time of Flight Spectrometer have been described. The Spectrometer would have an array of 50 Nos. of one meter long linear Position Sensitive Detector (PSD) placed vertically around the sample at a distance of 2000 mm. The sample receives periodic pulsed neutron beam coming through a Fermi chopper. The time and zone of detection of a scattered neutron in a PSD gives information of its flight time and path length, which will be used to calculate its energy. A neutron event zone (position) and time detection module for each PSD provides a 2 bit position/zone code and an event timing pulse. The path length assigned to a neutron detected in a zone (Z1, Z2 etc) in the PSD is the mean path length seen by the neutrons detected in that zone of the PSD. A Time recording unit described here receives event zone code and timing pulse for all the 50 detectors, tags a proper time window code to it, before streaming it to computer for calculation of the energy distribution of neutrons scattered from the sample

  7. Data acquisition and instrument control system for neutron spectrometers

    International Nuclear Information System (INIS)

    Naik, S.S.; Kotwal, Ismat; Chandak, R.M.; Gaonkar, V.G.

    2004-01-01

    A personal computer (PC)-based data acquisition and instrument control system has been developed for neutron spectrometers in Dhruva reactor hall and Guide Tube laboratory. Efforts have been made to make the system versatile so that it can be used for controlling various neutron spectrometers using single end-on detector in step scan mode. Commercially available PC add-on cards have been used for input-output and timer-counter operations. An interface card and DC motor driver card have been developed indigenously. Software for the system has been written in Visual C++ language using MS Windows operating system. This data acquisition and instrument control system is successfully controlling four spectrometers at Dhruva reactor. (author)

  8. Beam-transport optimization for cold-neutron spectrometer

    Directory of Open Access Journals (Sweden)

    Nakajima Kenji

    2015-01-01

    Full Text Available We report the design of the beam-transport system (especially the vertical geometry for a cold-neutron disk-chopper spectrometer AMATERAS at J-PARC. Based on the elliptical shape, which is one of the most effective geometries for a ballistic mirror, the design was optimized to obtain, at the sample position, a neutron beam with high flux without serious degrading in divergence and spacial homogeneity within the boundary conditions required from actual spectrometer construction. The optimum focal point was examined. An ideal elliptical shape was modified to reduce its height without serious loss of transmission. The final result was adapted to the construction requirements of AMATERAS. Although the ideas studied in this paper are considered for the AMATERAS case, they can be useful also to other spectrometers in similar situations.

  9. Neutron diagnostics using compton suppression gamma-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hong, S. P.; Kang, B. S. [Lab. Of Radiation Convergence Science, Dept. of Radiological Science, College of Medical Science, Konyang University, Daejeon (Korea, Republic of); Kim, C. S.; Cheon, M. S.; Cho, S. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Various neutron diagnostic systems such as a fission chamber, stilbene spectrometers, and a neutron activation system (NAS) have been installed at KSTAR for more accurate detection of neutron flux. Among the systems, the NAS is the most reliable and robust tool, and the measurement data of it generally are to be used for calibration of other systems. The Compton suppression gamma-ray spectrometer which can suppress the expected background, noise signal and Compton scattering was used to measure the gamma-rays of neutron activated samples. In this study, the encapsulated indium samples which are installed and irradiated by the neutrons released from the nuclear fusion reactions in the Korea Superconducting Tokamak Advanced Research (KSTAR) was used and measured using Compton suppressed gamma-ray spectrometer to minimize the measurement error. From the experimental results, the statistical error was decreased by Compton suppression system. the statistical error of the measured sample activity in the Compton suppressed system is estimated to be about 2.3 %, and the statistical error of the measured sample activity in the non-suppressed system was estimated to be about 4.9 %. It was found that the system can reduce the measurement error effectively. It is confirmed that this system can be applied to ITER TBM and future nuclear fusion devices.

  10. Personnel neutron dose assessment upgrade: Volume 2, Field neutron spectrometer for health physics applications

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Reece, W.D.; Miller, S.D.

    1988-07-01

    Both the (ICRP) and the (NCPR) have recommended an increase in neutron quality factors and the adoption of effective dose equivalent methods. The series of reports entitled Personnel Neutron Dose Assessment Upgrade (PNL-6620) addresses these changes. Volume 1 in this series of reports (Personnel Neutron Dosimetry Assessment) provided guidance on the characteristics, use, and calibration of personnel neutron dosimeters in order to meet the new recommendations. This report, Volume 2: Field Neutron Spectrometer for Health Physics Applications describes the development of a portable field spectrometer which can be set up for use in a few minutes by a single person. The field spectrometer described herein represents a significant advance in improving the accuracy of neutron dose assessment. It permits an immediate analysis of the energy spectral distribution associated with the radiation from which neutron quality factor can be determined. It is now possible to depart from the use of maximum Q by determining and realistically applying a lower Q based on spectral data. The field spectrometer is made up of two modules: a detector module with built-in electronics and an analysis module with a IBM PC/reg sign/-compatible computer to control the data acquisition and analysis of data in the field. The unit is simple enough to allow the operator to perform spectral measurements with minimal training. The instrument is intended for use in steady-state radiation fields with neutrons energies covering the fission spectrum range. The prototype field spectrometer has been field tested in plutonium processing facilities, and has been proven to operate satisfactorily. The prototype field spectrometer uses a 3 He proportional counter to measure the neutron energy spectrum between 50 keV and 5 MeV and a tissue equivalent proportional counter (TEPC) to measure absorbed neutron dose

  11. A neutron spectrometer for neutron energies between 1 eV and 10 keV

    International Nuclear Information System (INIS)

    Wang, C.K.; Blue, T.E.

    1988-01-01

    In boron neutron capture therapy (BNCT), it is the consensus that epithermal neutron beams have advantages over thermal beams in treating deep-seated brain tumors, and large neutron fields have advantages over narrow beams, since whole-brain irradiations are thought to be necessary in many cases. Epithermal neutron sources for BNCT, which include filtered reactor neutron beams and moderated reactor neutron fields, are currently being developed at many institutions around the world. Neutrons with energies between 1 eV and 10 keV are most suitable for treating brain tumors. However, techniques for measuring neutron spectra in a vacuum in this energy range are not well developed. This paper describes a new type of neutron spectrometer that has a set of response functions that peak at equally spaced intervals on a logarithmic energy scale ranging from 1 eV to 10 keV; therefore, neutron spectra (or histograms) in this energy range can be obtained by properly applying spectrum unfolding techniques to the measured data. The spectrometer is applicable for measurements in a vacuum for both narrow neutron beams and wide neutron fields

  12. Performance of a Moderating Neutron Spectrometer That Uses Scintillating Fibers

    Energy Technology Data Exchange (ETDEWEB)

    Bliss, Mary; Craig, Richard A.; Barnett, Debra S.; Anderson, Dale N.; Smart, John E.; Knopf, Michael A.; Hartley, Stacey A.

    2001-08-03

    The Bonner sphere is the canonical example of instruments that provide a measure of neutron spectra by using moderating and absorbing materials together with thermal-neutron detectors. For such spectrometers, the instrument response reflects a statistical average of the energy spectrum. Pacific Northwest National Laboratory has developed neutron-sensitive cerium-activated scintillating fibers composed of lithium-silicate glass. These fibers present an enabling technology for efficient neutron spectroscopy. A moderating spectrometer was built as a testbed for materials identification. Based on the results of Monte Carlo experiments, six fiber layers are separated by polyethylene layers whose thickness has been chosen to maximize neutron spectral information. The completed, self-contained instrument, including electronics and data logging computer has a mass less than 35 kg, slightly more than half of which is polyethylene. Measurements have been performed by this instrument with various sources representing hard and soft neutron spectra. Because this instrument is a technology testbed, the data are recorded as pulse-height spectra. Results and future directions are presented.

  13. Development of the LunaH-Map miniature neutron spectrometer

    Science.gov (United States)

    Johnson, Erik B.; Hardgrove, Craig; Starr, Richard; Vogel, Sam; Frank, Rebecca; Stoddard, Graham; West, Stephen; Christian, James

    2017-08-01

    There is strong evidence that water-ice is relatively abundant within permanently shadowed lunar surface materials, particularly at the poles. Evidence for water-ice has been observed within the impact plume of the LCROSS mission and is supported by data gathered from the Lunar Exploration Neutron Detector (LEND) and the Lunar Prospector Neutron Spectrometer (LPNS). Albedo neutrons from the Moon are used for detection of hydrogen, where the epi-thermal neutron flux decreases as hydrogen content increases. The origin on the concentration of water within permanently shadowed regions is not completely understood, and the Lunar Polar Hydrogen Mapper (LunaH-Map) mission is designed to provide a high-resolution spatial distribution of the hydrogen content over the southern pole using a highly elliptical, low perilune orbit. The LunaH-Map spacecraft is a 6U cubesat consisting of the Miniature Neutron Spectrometer (Mini-NS). Mini-NS is not collimated, requiring a low altitude to achieve a higher spatial resolution compared to previous missions. To develop a compact neutron detector for epi-thermal neutrons, the Mini-NS comprises of 2-cm thick slabs of CLYC (Cs2LiYCl6), which provide a sensitivity similar to a 10-atm, 5.7-cm diameter He-3 tubes, as used in LPNS. The Mini-NS digital processing electronics can discriminate by shape and height to determine signal (albedo neutrons) from background (cosmic rays). The Mini-NS achieves a total active sensing area of 200 cm2 and is covered with a cadmium sheet to shield against thermal neutrons. The research and development on the detector modules show a robust design ready for space flight.

  14. An active pixels spectrometers for neutronic fields metrology

    International Nuclear Information System (INIS)

    Taforeau, Julien

    2013-01-01

    The fundamental metrology is responsible for the sustainability of the measurement systems and handles to supply the reference standards. Concerning the metrology of ionizing radiations and, in particular the neutron metrology, detectors standards are used to characterize reference fields, in terms of energy and fluence. The dosimeters or particle detectors are calibrated on these reference fields. This thesis presents the development of a neutron spectrometer neutron candidate to the status of primary standard for the characterization of neutron fields in the range from 5 to 20 MeV. The spectrometer uses the recoil proton telescope as detection principle; the CMOS technology, through three sensor positions, is taking advantage to realize the tracking of protons. A Si(Li) detector handles the measure of the residual proton energy. The device simulations, realized under MCNPX, allow to estimate its performances and to validate the neutron energy reconstruction. An essential step of characterization of the telescope elements and in particular of CMOS sensors is also proposed to guarantee the validity of posterior experimental measurements. The tests realized as well in mono-energy fields as in radionuclide source show the very good performances of the system. The quantification of uncertainties indicates an energy estimation with 1.5 % accuracy and a resolution of less than 6 %. The fluence measurement is performed with an uncertainty about 4 to 6%. (author)

  15. Time coder for slow neutron time-of-flight spectrometer

    International Nuclear Information System (INIS)

    Grashilin, V.A.; Ofengenden, R.G.

    1988-01-01

    Time coder for slow neutron time-of-flight spectrometer is described. The time coder is of modular structure, is performed in the CAMAC standard and operates on line with DVK-2 computer. The main coder units include supporting generator, timers, time-to-digital converter, memory unit and crate controller. Method for measuring background symmetrically to the effect is proposed for a more correct background accounting. 4 refs.; 1 fig

  16. Neutron dosimetry; Dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Fratin, Luciano

    1993-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is

  17. A high resolution, low background fast neutron spectrometer

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S; Adams, J M; Nico, J S; Thompson, A K

    2002-01-01

    We discuss the possibility to create a spectrometer of full absorption based on liquid scintillator doped with enriched sup 6 Li. Of specific interest, the spectrometer will have energy resolution estimated to lie in the range 5-10% for 14 MeV neutrons. It will be sensitive to fluxes from 10 sup - sup 4 to 10 sup 6 cm sup - sup 2 s sup - sup 1 above a threshold of 1 MeV in a gamma-background of up to 10 sup 4 s sup - sup 1. The detector's efficiency will be determined by the volume of the scintillator only (approx 3 l) and is estimated to be 0.2-10%. The main reason for the poor resolution of an organic scintillator based spectrometer of full absorption is a non-linear light-yield of the scintillator for recoil protons. The neutron energy is occasionally distributed among recoil protons, and due to non-linear light-yield the total amount of light from all recoil protons ambiguously determines the initial neutron energy. The high-energy resolution will be achieved by compensation of the non-linear light-yield ...

  18. Upgrade of the compact neutron spectrometer for high flux environments

    Science.gov (United States)

    Osipenko, M.; Bellucci, A.; Ceriale, V.; Corsini, D.; Gariano, G.; Gatti, F.; Girolami, M.; Minutoli, S.; Panza, F.; Pillon, M.; Ripani, M.; Trucchi, D. M.

    2018-03-01

    In this paper new version of the 6Li-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. New metal contacts approaching ohmic conditions were deposited on the diamonds suppressing build-up of space charge observed in the previous prototypes. New passive preamplification of the signal at detector side was implemented to improve its resolution. This preamplification is based on the RF transformer not sensitive to high neutron flux. The compact mechanical design allowed to reduce detector size to a tube of 1 cm diameter and 13 cm long. The spectrometer was tested in the thermal column of TRIGA reactor and at the DD neutron generator. The test results indicate an energy resolution of 300 keV (FWHM), reduced to 72 keV (RMS) excluding energy loss, and coincidence timing resolution of 160 ps (FWHM). The measured data are in agreement with Geant4 simulations except for larger energy loss tail presumably related to imperfections of metal contacts and glue expansion.

  19. Neutron Detection with a Cryogenic Spectrometer

    CERN Document Server

    Bell, Z W; Cristy, S S; Lamberti, V E

    2003-01-01

    Cryogenic calorimeters are used for x-ray detection because of their exquisite energy resolution and have found application in x-ray astronomy, and the search for dark matter. These devices operate by detecting the heat pulse produced by ionization in an absorber cooled to temperatures below 1 K. Such temperatures are needed to lower the absorber's heat capacity to the point that the deposition of even a few eV results in a measurable temperature excursion. Typical absorbers for dark matter measurements are massive Si or Ge crystals, and, with Ge, have achieved a resolution of 650 eV at 10 keV. Chow, et al., report the measurement of the 60 keV emission from sup 2 sup 4 sup 1 Am with 230 eV resolution using a superconducting tin absorber. Cunningham, et al., also using a superconducting tin absorber, have recently reported a four-fold improvement over Chow. With such results being reported from the x- and gamma-ray world it is natural to examine the possibilities for cryogenic neutron spectroscopy. Such a det...

  20. Handheld dual thermal neutron detector and gamma-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stowe, Ashley C.; Burger, Arnold; Bhattacharya, Pijush; Tupitsyn, Yevgeniy

    2017-05-02

    A combined thermal neutron detector and gamma-ray spectrometer system, including: a first detection medium including a lithium chalcopyrite crystal operable for detecting neutrons; a gamma ray shielding material disposed adjacent to the first detection medium; a second detection medium including one of a doped metal halide, an elpasolite, and a high Z semiconductor scintillator crystal operable for detecting gamma rays; a neutron shielding material disposed adjacent to the second detection medium; and a photodetector coupled to the second detection medium also operable for detecting the gamma rays; wherein the first detection medium and the second detection medium do not overlap in an orthogonal plane to a radiation flux. Optionally, the first detection medium includes a .sup.6LiInSe.sub.2 crystal. Optionally, the second detection medium includes a SrI.sub.2(Eu) scintillation crystal.

  1. FOCUS: neutron time-of-flight spectrometer at SINQ: recent progress

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, S.; Mesot, J.; Holitzner, L. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Hempelmann, R. [Saarbruecken Univ. (Germany)

    1997-09-01

    At the Swiss neutron spallation source SINQ a time-of-flight spectrometer for cold neutrons is under construction. The design foresees a Hybrid solution combining a Fermi chopper with a doubly focusing crystal monochromator. During 1996 important progress has been made concerning the main spectrometer components such as the spectrometer housing and the detector system. (author) 2 figs., 3 refs.

  2. RESPECT: Neutron resonance spin-echo spectrometer for extreme studies

    Energy Technology Data Exchange (ETDEWEB)

    Georgii, R., E-mail: Robert.Georgii@frm2.tum.de [Physik-Department, Technische Universität München, James-Franck-Str. 1, D-85748 Garching (Germany); Heinz Maier-Leibnitz Zentrum, Technische Universität München, Lichtenbergstr. 1, D-85748 Garching (Germany); Kindervater, J. [Physik-Department, Technische Universität München, James-Franck-Str. 1, D-85748 Garching (Germany); Institute for Quantum Matter and Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street Baltimore, MD 21218 (United States); Pfleiderer, C.; Böni, P. [Physik-Department, Technische Universität München, James-Franck-Str. 1, D-85748 Garching (Germany)

    2016-11-21

    We propose the design of a REsonance SPin-echo spECtrometer for exTreme studies, RESPECT, that is ideally suited for the exploration of non-dispersive processes such as diffusion, crystallization, slow dynamics, tunneling processes, crystal electric field excitations, and spin fluctuations. It is a variant of the conventional neutron spin-echo technique (NSE) by (i) replacing the long precession coils by pairs of longitudinal neutron spin-echo coils combined with RF-spin flippers and (ii) by stabilizing the neutron polarization with small longitudinal guide fields that can in addition be used as field subtraction coils thus allowing to adjust the field integrals over a range of 8 orders of magnitude. Therefore, the dynamic range of RESPECT can in principle be varied over 8 orders of magnitude in time, if neutrons with the required energy are made available. Similarly as for existing NSE-spectrometers, spin echo times of up to approximately 1 μs can be reached if the divergence and the correction elements are properly adjusted. Thanks to the optional use of neutron guides and the fact that the currents for the correction coils are much smaller than in standard NSE, intensity gains of at least one order of magnitude are expected, making the concept of RESPECT also competitive for operation at medium flux neutron sources. RESPECT can also be operated in a MIEZE configuration allowing the investigation of relaxation processes in depolarizing environments as they occur when magnetic fields are applied at the sample position, i.e. for the investigation of the dynamics of flux lines in superconductors, magnetic fluctuations in ferromagnetic materials, and samples containing hydrogen.

  3. A comparison of different neutron spectroscopy systems at the reactor facility VENUS

    CERN Document Server

    Vanhavere, F; Chartier, J L; Itie, C; Rosenstock, W; Koeble, T; D'Errico, F

    2002-01-01

    The VENUS facility is a zero-power research reactor mainly devoted to studies on LWR fuels. Localised high-neutron rates were found around the reactor, with a neutron/gamma dose equivalent rate ratio as high as three. Therefore, a study of the neutron dosimetry around the reactor was started some years ago. During this study, several methods of neutron spectroscopy were employed and a study of individual and ambient dosemeters was performed. A first spectrometric measurement was done with the IPSN multisphere spectrometer in three positions around the reactor. Secondly, the ROSPEC spectrometer from the Fraunhofer Institut was used. The spectra were also measured with the bubble interactive neutron spectrometer. These measurements were compared with a numerical simulation of the neutron field made with the code TRIPOLI-3. Dosimetric measurements were made with three types of personal neutron dosemeters: an albedo type, a track etch detector and a bubble detector.

  4. Development of inelastic neutron spectrometer (DC-TOF) and utilization

    International Nuclear Information System (INIS)

    Park, Je Geun; So, J. Y.; Moon, M. K.; Choi, Y. H.; Cho, S. J.; Lee, C. H.; Nam, U. W.; Kim, H. Y.; Kim, H. J.

    2010-08-01

    DC-TOF is an inelastic neutron spectrometer with potentially very wide applications to areas such as physics, chemistry, biology, and material engineering. And it is the most technically challenging and advanced instrument by using high speed choppers rotating up to 20,000 RPM and wide detector of steradian producing data in the order of a few hundred Mbyte. Through this project, we have successfully developed DC-TOF at KAERI with the development of the following key technologies : - Detector Electronics - Data acquisition software - Data reduction software. We believe that DC-TOF will become a workhorse instrument for the wide community of sciences in Korea

  5. Time-of-flight neutron-correlation spectrometers and their electronics

    International Nuclear Information System (INIS)

    Tsitovich, A.P.

    1976-01-01

    The review is made of the data published on neutron-correlation time-of-flight spectrometers. The operating principle of a correlation neutron time-of-flight spectrometer implies that the neutron beam serving as an input signal is modulated by an inadvertent law, and time spectrum is found by the way of measuring the mutually correlating function of the input signal and the output signal of the neutron detector. The correlation method is grounded in brief, and the specific features of the neutron-beam choppers, pulse analyzers and time encoders used in the correlation spectrometers are given. Also considered are the main functions of the computers operating in line with the spectrometers. As compared with the ordinary time-of-flight spectrometers, the neutron-correlation ones are more effective, which explains their wide application in nuclear spectrometry

  6. An acceptance diagram analysis of the contaminant pulse removal problem with direct geometry neutron chopper spectrometers

    International Nuclear Information System (INIS)

    Copley, J.R.D.

    2003-01-01

    Phased choppers are used to produce pulsed beams of monochromatic neutrons at research reactors and spallation neutron sources. Depending on the design of the instrument, it is very possible that the choppers will transmit neutrons with wavelengths other than those within the desired band of wavelengths. One or more additional choppers are typically needed to remove these contaminant pulses. We describe a method of determining the wavelength- and time-dependent transmission of a system of choppers using acceptance diagrams. The method is illustrated with calculations for the Disk Chopper Spectrometer at the NIST Center for Neutron Research and the proposed Cold Neutron Chopper Spectrometer at the Spallation Neutron Source (Oak Ridge, TN)

  7. Development of multi-moderator neutron spectrometer using a pair of 6Li and 7Li glass scintillators

    International Nuclear Information System (INIS)

    Taniguchi, Shingo; Takada, Masashi; Nakamura, Takashi

    2001-01-01

    A multi-moderator spectrometer using a pair of 6 Li and 7 Li glass scintillators has been developed. This new type of neutron spectrometer can measure the neutron spectrum in a mixed field of neutrons, charged particles and gamma-rays. The particle identification capability was investigated in neutron-gamma-ray and neutron-proton mixed fields and the neutron response functions of the spectrometer were obtained by calculations and experiments up to 200 MeV. This spectrometer has been applied to measure neutron spectrum in a neutron-proton mixed field, produced by bombarding a Be target by 70 MeV protons from the cyclotron

  8. Charged-particle magnetic-quadrupole spectrometer for neutron induced reactions

    International Nuclear Information System (INIS)

    Haight, R.C.; Grimes, S.M.; Tuckey, B.J.; Anderson, J.D.

    1975-01-01

    A spectrometer has been developed for measuring the charged particle production cross sections and spectra in neutron-induced reactions. The spectrometer consists of a magnetic quadrupole doublet which focuses the charged particles onto a silicon surface barrier detector telescope which is 2 meters or more from the irradiated sample. Collimators, shielding, and the large source-to-detector distance reduce the background enough to use the spectrometer with a 14-MeV neutron source producing 4 . 10 12 n/s. The spectrometer has been used in investigations of proton, deuteron, and alpha particle production by 14-MeV neutrons incident on various materials. Protons with energies as low as 1.1 MeV have been measured. The good resolution of the detectors has also made possible an improved measurement of the neutron- neutron scattering length from the 0 0 proton spectrum from deuteron breakup by 14-MeV neutrons

  9. A new/old type of neutron spectrometer

    International Nuclear Information System (INIS)

    Vylet, V.; Fasso, A.; Luckau, N.

    1998-01-01

    The proposed portable spectrometer is a large sphere made of a plastic scintillator loaded with boron, possibly enriched with boron 10. The sphere is divided into spherical shells coated with a reflective or opaque material. Each shell is made of two hemispherical shells or smaller segments. Each segment is connected by a light-guide to a photomultiplier or a photodiode. It might be possible to use miniature photomultipliers directly embedded in detector layers. Each shell measures the thermal fluence at a different moderator depth and the set of shell responses can be used to unfold the original neutron spectrum, covering the range of energies from thermal to 20 MeV. (M.D.)

  10. DESIGN IMPROVEMENT OF A LIQUID-MODERATOR-BASED NEUTRON SPECTROMETER FOR BNCT.

    Science.gov (United States)

    Tamaki, Shingo; Kusaka, Sachie; Sato, Fuminobu; Murata, Isao

    2017-10-27

    Boron neutron capture therapy is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to measure the neutron spectrum in the treatment field is not well established. Many researchers are making efforts to improve the spectrometers. To solve this problem, we are developing a liquid-moderator-based neutron spectrometer that is based on the same theory as that of the Bonner sphere spectrometer. The spectrometer uses a liquid moderator and absorber. In the present study, we performed a design study to improve the previously developed liquid-moderator-based neutron spectrometer. By carrying out a numerical simulation of the designed new spectrometer, we finally assessed and confirmed the validity of this spectrometer numerically. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. The TOFOR Neutron Spectrometer For High-Performance Measurements of D Plasma Fuel Ion Properties

    International Nuclear Information System (INIS)

    Johnson, M. Gatu; Giacomelli, L.; Hjalmarsson, A.; Weiszflog, M.; Sunden, E. Andersson; Conroy, S.; Ericsson, G.; Hellesen, C.; Ronchi, E.; Sjoestrand, H.; Kaellne, J.; Gorini, G.; Tardocch, M.

    2008-01-01

    The impact of scattered neutrons on the total flux reaching the TOFOR spectrometer at JET has been studied to allow for improvement of the data analysis. The scattered neutrons are demonstrated to contribute significantly to the flux. This will have implications for any neutron diagnostic on ITER

  12. The development of a spectrometer for 14 MeV neutrons from fusion

    International Nuclear Information System (INIS)

    Aronsson, D.

    1991-01-01

    A spectrometer for 14 MeV neutrons, to be used for fusion plasma diagnostics at JET, was developed. The spectrometer utilizes neutron scattering in a polyethylene foil with the detection of the scattered neutron and its associated recoil proton. For the detection of 12 MeV protons we have tested silicon surface barrier detectors, lithium-drifted silicon detectors and high purity germanium detectors. The lithium-drifted detectors were finally selected for use in the spectrometer. The lithium-drifted silicon diodes have also been used for direct spectrometry, utilizing the neutron induced charged particle reactions in silicon. The methods used for the energy calibration and the timing calibration of the diodes, both during the installation of the spectrometer and during operation, are described. The detection of 2 MeV neutrons is done by fast plastic scintillators. Since the neutron generator which was used to test the detectors supplies 14 MeV or 2.5 MeV neutrons only, a neutron energy converter has to be constructed to study the detectors at other neutron energies. In the actual spectrometer an array of scintillation neutron detectors is used. A method of calibrating such an array of detectors with a gamma source was elaborated and is also described here. The result of the calibration is a set of parameters than can be used to determine the high voltage settings and the discriminator levels that are needed to achieve homogeneous sensitivity for all the detectors of the array. The energy scale itself was then calibrated by using gamma sources of various energies. To test the spectrometer as a whole at a neutron generator, a test bed was constructed. A lithium-drifted silicon diode was used to measure the neutron flux and the neutron energy resolution in the test bed. (au)

  13. Neutron and gamma-ray spectra of {sup 239}PuBe and {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Vega-Carrillo, H.R. E-mail: rvega@cantera.reduaz.mx; Manzanares-Acuna, Eduardo; Becerra-Ferreiro, A.M.; Carrillo-Nunez, Aureliano

    2002-08-01

    Neutron and gamma-ray spectra of {sup 239}PuBe and {sup 241}AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a {sup 6}LiI(Eu) scintillator. The {sup 239}PuBe neutron spectrum was measured in an open environment, while the {sup 241}AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the {sup 241}AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity.

  14. Neutronic calculations in support of the design of the ITER High Resolution Neutron Spectrometer

    International Nuclear Information System (INIS)

    Moro, F.; Esposito, B.; Marocco, D.; Villari, R.; Petrizzi, L.; Sunden, E. Andersson; Conroy, S.; Ericsson, G.; Johnson, M. Gatu; Dapena, M.

    2011-01-01

    This paper presents the results of neutronic calculations performed to address important issues related to the optimization of the ITER HRNS (High resolution Neutron Spectrometer) design, in particular concerning the definition of the collimator and the choice of the detector system. The calculations have been carried out using the MCNP5 Monte Carlo code in a full 3-D geometry. The HRNS collimation system has been included in the latest MCNP ITER 40 o model (Alite-4). The ITER scenario 2 reference DT plasma fusion neutron source peaked at 14.1 MeV with Gaussian energy distribution has been used. Neutron fluxes and energy spectra (>1 MeV) have been evaluated at different positions along the HRNS collimator and at the detector location. The noise-to-signal ratio (i.e. the ratio of collided to uncollided neutrons), the breakdown of the collided spectrum into its components, the dependency on the first wall aperture and the gamma-ray spectra at the detector position have also been analyzed. The impact of the results on the design of the HRNS diagnostic system is discussed.

  15. Neutron Brillouin scattering experiments with pulsed neutrons on high resolution chopper spectrometer HRC

    International Nuclear Information System (INIS)

    Itoh, S; Yokoo, T; Endoh, Y; Kawana, D; Kaneko, Y; Tokura, Y; Fujita, M; Yoshida, K; Saito, K; Inami, N; Takeichi, Y; Ono, K

    2014-01-01

    We improved the High Resolution Chopper Spectrometer (HRC), which is installed at MLF in J-PARC, in order to perform neutron Brillouin scattering (NBS) experiments, and successfully demonstrated a feasibility of this method. Gapless spin-wave excitations were observed in La 0.8 Sr 0.2 MnO 3 , which were in good agreement with previous results using single crystals, on the other hand, a large energy gap in the ferromagnetic spin waves was found in SrRuO 3 . Spin-wave peaks in a permanent magnet Nd 2 Fe 14 B were on the dispersion curve determined previously using a single crystal. Excitations, so-called fast sound, in liquid D 2 O were in a good agreement with previous inelastic neutron scattering experiments and the dispersion curve were extended to the lower Q region.

  16. The polarized neutron spectrometer REMUR at the pulsed reactor IBR-2

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Zhernenkov, K.N.; Kozhevnikov, S.V.; Nikitenko, Yu.V.; Petrenko, A.V.; Lauter, H.J.; Lauter-Pasyuk, V.

    2004-01-01

    At the Laboratory of Neutron Physics (JINR, Dubna) the new polarized neutron spectrometer REMUR has been constructed and commissioned. The spectrometer REMUR is dedicated to investigations of multilayers and surfaces by polarized neutron reflection and of the inhomogeneous state of solids by diffuse small-angle polarized neutron scattering. The spectrometer operates in the neutron wavelength interval 1-10 Angstroem. In the reflectometry mode it allows one to complete polarization analysis and neutron position-sensitive detection within the solid angle of scattering 2.2·10 -4 rad. The spectrometer ensures good statistics of the reflectometric data in the scattering wave vector interval 3·10 -3 - 5·10 -1 Angstroem -1 . In the small-angle scattering mode the spectrometer allows the investigation of neutron scattering processes without spin-flip over the detector's neutron registration solid angle interval from 4·10 -3 to 10 -1 rad and the scattering wave vector interval from 0.006-0.15 to 0.03-0.7 Angstroem -1 , respectively

  17. A new small-angle neutron scattering spectrometer at China Mianyang research reactor

    Science.gov (United States)

    Peng, Mei; Sun, Liangwei; Chen, Liang; Sun, Guangai; Chen, Bo; Xie, Chaomei; Xia, Qingzhong; Yan, Guanyun; Tian, Qiang; Huang, Chaoqiang; Pang, Beibei; Zhang, Ying; Wang, Yun; Liu, Yaoguang; Kang, Wu; Gong, Jian

    2016-02-01

    A new pinhole small-angle neutron scattering (SANS) spectrometer, installed at the cold neutron source of the 20 MW China Mianyang Research Reactor (CMRR) in the Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, has been put into use since 2014. The spectrometer is equipped with a multi-blade mechanical velocity selector, a multi-beam collimation system, and a two-dimensional He-3 position sensitive neutron detector. The q-range of the spectrometer covers from 0.01 nm-1 to 5.0 nm-1. In this paper, the design and characteristics of the SANS spectrometer are described. The q-resolution calculations, together with calibration measurements of silver behenate and a dispersion of nearly monodisperse poly-methyl-methacrylate nanoparticles indicate that our SANS spectrometer has a good performance and is now in routine service.

  18. MESSENGER E/V/H GRNS 2 NEUTRON SPECTROMETER RAW DATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER NS uncalibrated observations, also known as EDRs. The NS experiment is a neutron spectrometer designed to...

  19. Proposal for a rotating analyser single crystal spectrometer at a pulsed neutron source

    International Nuclear Information System (INIS)

    Geick, R.; Tietze, H.

    1986-01-01

    We propose a new type of crystal analyser time-of-flight spectrometer for elastic and inelastic single crystal measurements at a pulsed neutron source. Using a nonuniformly rotating analyser, a flexibility of the spectrometer is achieved intermediate between that of the crystal analyser time-of-flight spectrometers like MAX and Constant-Q and the triple axis spectrometer. In detail, we discuss constant-(h/2π)ω and constant-(Q/vertical strokeQvertical stroke) scans for our spectrometer and the nonuniform rotation of the analyser necessary for these special scans. (orig.)

  20. Time-of-flight spectrometer for the measurement of gamma correlated neutron spectra

    International Nuclear Information System (INIS)

    Andriashin, A.V.; Devkin, B.V.; Lychagin, A.A.; Minko, J.V.; Mironov, A.N.; Nesterenko, V.S.; Sztaricskai, T.; Petoe, G.; Vasvary, L.

    1986-01-01

    A time-of-flight spectrometer for the measurement of gamma correlated neutron spectra from (n,xnγ) reactions is described. The operation and the main parameters are discussed. The resolution in the neutron channel is 2.2 ns/m at the 150 keV neutron energy threshold. A simultaneous measurement of the time-of-flight and amplitude distributions makes it possible to study gamma correlated neutron spectra as well as the prompt gamma spectra in coincidence with selected energy neutrons. In order to test the spectrometer, measurements of the neutron spectrum in coincidence with the 846 keV gamma line of 56 Fe were carried out at an incident neutron energy of 14.1 MeV. (Auth.)

  1. Time-of-flight spectrometer for the measurement of gamma correlated neutron spectra

    International Nuclear Information System (INIS)

    Andryashin, A.V.; Devlein, B.V.; Lychagin, A.A.; Minko, Y.V.; Mironov, A.N.; Nesterenko, V.S.

    1986-01-01

    A time-of-flight spectrometer for the measurement of gamma correlated neutron spectra form (n,xnγ) reactions is described. The operation and the main parameters are discussed. The resolution in the neutron channel is 2.2 ns/m at the 150 keV neutron energy threshold. A simultaneous measurement of the time-of-flight and amplitude distributions makes it possible to study gamma correlated neutron spectra as well as the prompt gamma spectra in coincidence with selected energy neutrons. In order to test the spectrometer, measurements of the neutron spectrum in coincidence with the 846 keV gamma line of 56 Fe were carried out at an incident neutron energy of 14.1 MeV. (author). 3 figs., 6 refs

  2. Designing an extended energy range single-sphere multi-detector neutron spectrometer

    International Nuclear Information System (INIS)

    Gómez-Ros, J.M.; Bedogni, R.; Moraleda, M.; Esposito, A.; Pola, A.; Introini, M.V.; Mazzitelli, G.; Quintieri, L.; Buonomo, B.

    2012-01-01

    This communication describes the design specifications for a neutron spectrometer consisting of 31 thermal neutron detectors, namely Dysprosium activation foils, embedded in a 25 cm diameter polyethylene sphere which includes a 1 cm thick lead shell insert that degrades the energy of neutrons through (n,xn) reactions, thus allowing to extension of the energy range of the response up to hundreds of MeV neutrons. The new spectrometer, called SP 2 (SPherical SPectrometer), relies on the same detection mechanism as that of the Bonner Sphere Spectrometer, but with the advantage of determining the whole neutron spectrum in a single exposure. The Monte Carlo transport code MCNPX was used to design the spectrometer in terms of sphere diameter, number and position of the detectors, position and thickness of the lead shell, as well as to obtain the response matrix for the final configuration. This work focuses on evaluating the spectrometric capabilities of the SP 2 design by simulating the exposure of SP 2 in neutron fields representing different irradiation conditions (test spectra). The simulated SP 2 readings were then unfolded with the FRUIT unfolding code, in the absence of detailed pre-information, and the unfolded spectra were compared with the known test spectra. The results are satisfactory and allowed approving the production of a prototypal spectrometer.

  3. The Polarized Neutron Spectrometer REMUR at the Pulsed Reactor IBR-2

    CERN Document Server

    Aksenov, V L; Kozhevnikov, S V; Lauter, H; Lauter-Pasyuk, V; Nikitenko, Yu V; Petrenko, A V

    2004-01-01

    A new polarized neutron spectrometer REMUR has been constructed and commissioned. The spectrometer REMUR is dedicated to investigations of multilayers and surfaces by polarized neutron reflection and of the inhomogeneous state of solids by diffuse small-angle polarized neutron scattering. The spectrometer operates in the neutron wavelength interval 1\\div 10 A. In the reflectometry mode it allows one to complete polarization analysis and neutron position-sensitive detection within the solid angle of scattering 2.2\\cdot 10^{-4} rad. The spectrometer ensures good statistics of the reflectometric data in the scattering wave vector interval 3\\cdot 10^{-3}\\div 5\\cdot 10^{-1} A^{-1}. In the small-angle scattering mode the spectrometer allows the investigation of neutron scattering processes without spin-flip over the detector's neutron registration solid angle interval from 4\\cdot 1-^{-3} to 10^{-1} rad and the scattering wave vector interval from 0.006\\div 0.15 to 0.03\\div 0.7 A^{-1}, respectively.

  4. Development of single-exposure, multidetector neutron spectrometers: the NESCOFI'at'BTF project

    International Nuclear Information System (INIS)

    Bedogni, R.; Esposito, A.; Gentile, A.; Mazzitelli, G.; Buonomo, B.; Gomez-Ros, J.M.; Bortot, D.; Pola, A.; Introini, M.V.

    2014-01-01

    NESCOFI'at'BTF is a 3-y project (2011-13) supported by the Scientific Commission 5 of INFN (Italy). The target is the development of neutron spectrometers similar to the Bonner spheres, in terms of response energy interval and accuracy, but able to determine the neutron spectrum in only one exposure. These devices embed multiple (10 to 30) thermal neutron detectors (TNDs) within a single moderator. Two prototypes, called Spherical Spectrometer (SP 2 ) and cylindrical spectrometer (CYSP), have been set up. Whilst SP 2 has spherical geometry and nearly isotropic response, the CYSP has cylindrical geometry and is intended to be used as a directional spectrometer. Suitable active TNDs will be embedded in the final version of the devices. The resulting instruments could be used as real-time neutron spectrometers in neutron-producing facilities. This communication describes the design criteria, numerical analysis, experimental issues, state-of-the-art and future developments connected with the development of these instruments. Two prototypal single-moderator neutron spectrometers, called SP 2 and CYSP, were designed in the framework of the INFN project NESCOFI'at'BTF. They are intended to be used as isotropic or directional spectrometers, respectively. At present, the SP 2 response matrix was tested with passive detectors, whilst the active version of the instrument is under fabrication. In contrast, the active CYSP is available and its response matrix was partially tested with an Am-Be source, obtaining a very satisfactory agreement. A full test of the CYSP response matrix, using reference neutron fields, is planned before the end of 2013. After the active version of both SP2 and CYSP will be set up and tested, these real-time on-line spectrometers could be replicated and distributed to third-party institutions under collaboration agreement. (authors)

  5. An NaI(Tl) spectrometer system for keV neutron radiative-capture reactions

    International Nuclear Information System (INIS)

    Ohsaki, T.; Nagai, Y.; Igashira, M.; Shima, T.; Suzuki, T.S.; Kikuchi, T.; Kobayashi, T.; Takaoka, T.; Kinoshita, M.; Nobuhara, Y.

    1999-01-01

    An NaI(Tl) spectrometer system has been installed to measure the cross section of a radiative neutron-capture reaction of a nucleus at an astrophysically relevant energy of between 10 and 500 keV. The system consists of two large anti-Compton NaI(Tl) spectrometers and a new data-taking system. The spectrometer can detect a discrete γ-ray emitted promptly from a neutron-capture state to its low-lying state, and the data-taking system can transfer events with much higher rates, about 30-times higher, compared to the existing system

  6. Design of the cold neutron triple-axis spectrometer at the China Advanced Research Reactor

    International Nuclear Information System (INIS)

    Cheng, P.; Zhang, Hongxia; Bao, W.; Schneidewind, A.; Link, P.; Grünwald, A.T.D.; Georgii, R.; Hao, L.J.; Liu, Y.T.

    2016-01-01

    The design of the first cold neutron triple-axis spectrometer at the China Advanced Research Reactor is presented. Based on the Monte Carlo simulations using neutron ray-tracing program McStas, the parameters of major neutron optics in this instrument are optimized. The neutron flux at sample position is estimated to be 5.6 ×10 7 n/cm 2 /s at neutron incident energy E i =5 meV when the reactor operates normally at the designed 60 MW power. The performances of several neutron supermirror polarizing devices are compared and their critical parameters are optimized for this spectrometer. The polarization analysis will be realized with a flexible switch from the unpolarized experimental mode.

  7. Direct mass measurements of light neutron-rich nuclei using fast recoil spectrometers

    International Nuclear Information System (INIS)

    Vieira, D.J.; Wouters, J.M.

    1987-01-01

    Extensive new mass measurement capabilities have evolved with the development of recoil spectrometers. In the Z = 3 to 9 neutron-rich region alone, 12 neutron-rich nuclei have been determined for the first time by the fast-recoil direct mass measurement method. A recent experiment using the TOFI spectrometer illustrates this technique. A systematic investigation of nuclei that lie along or near the neutron-drip line has provided a valuable first glimpse into the nuclear structure of such nuclei. No evidence for a large single-particle energy gap at N = 14 is observed; however, a change in the two-neutron separation model calculations, and is interpreted in terms of the smaller 1s/sub 1/2/ - 1s/sub 1/2/ interaction compared to that of the 0d/sub 5/2/ - 0d/sub 5/2/ neutron-neutron interaction. 18 refs., 7 figs., 1 tab

  8. Design of the cold neutron triple-axis spectrometer at the China Advanced Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, P.; Zhang, Hongxia; Bao, W. [Department of Physics, Beijing Key Laboratory of Opto-electronic Functional Materials & Micro-nano Devices, Renmin University of China, Beijing 100872 (China); Schneidewind, A. [Jülich Center for Neutron Science (JCNS), Forschungszentrum Jülich GmbH, Outstation at Heinz MaierCLeibnitz Zentrum (MLZ), D-85747 Garching (Germany); Link, P. [Heinz Maier-Leibnitz Zentrum, Technische Universität München, D-85748 Garching (Germany); Grünwald, A.T.D. [II. Physikalisches Institut, Universität zu Köln, D-50937 Köln (Germany); Georgii, R. [Heinz Maier-Leibnitz Zentrum, Technische Universität München, D-85748 Garching (Germany); Hao, L.J.; Liu, Y.T. [China Institute of Atomic Energy, PO Box-275-30, Beijing 102413 (China)

    2016-06-11

    The design of the first cold neutron triple-axis spectrometer at the China Advanced Research Reactor is presented. Based on the Monte Carlo simulations using neutron ray-tracing program McStas, the parameters of major neutron optics in this instrument are optimized. The neutron flux at sample position is estimated to be 5.6 ×10{sup 7} n/cm{sup 2}/s at neutron incident energy E{sub i}=5 meV when the reactor operates normally at the designed 60 MW power. The performances of several neutron supermirror polarizing devices are compared and their critical parameters are optimized for this spectrometer. The polarization analysis will be realized with a flexible switch from the unpolarized experimental mode.

  9. Characteristics of a new type of spectrometer for measuring intermediate neutrons

    International Nuclear Information System (INIS)

    Kudo, K.; Takeda, N.; Fukuda, A.

    1994-01-01

    A new type of spectrometer for measuring intermediate energy neutrons has been designed for exclude contributions by unwanted γ-rays. The detector assembly consists of a H 2 gas proportional counter surrounded by six 3 He gas proportional counters. The spectrometer is operated in principle by using successive double pulses produced by a proton recoil in the inner H 2 counter at first and then by a neutron capture in one of the outer counters. The response function, the energy distribution of scattered neutrons coming into the 3 He counters and the time distribution between the proton recoil and the neutron capture were calculated by using the modified NRESP Monte Carlo code. The results showed that the response has a characteristic peak corresponding to the incident neutron energy. The double pulse measuring technique will provide excellent features relevant to the measurement of intermediate neutrons existing together with γ-rays

  10. A portable 0.5- to 16-MeV neutron spectrometer using a liquid scintillator

    International Nuclear Information System (INIS)

    Clark, J.C.; Thorngate, J.H.

    1991-01-01

    We have been developing a portable neutron spectrometer based on a liquid scintillator detector that is capable of measuring fast neutron spectra in the range of 0.5 to 16 MeV. These spectral data are needed for the calibration of neutron dosimeters and calculation of fluence-to-dose conversion factors. Recent development of low-power integrated circuits and the availability of powerful low-cost computers combine to make possible the development of a truly portable instrument. The complete spectrometer will consist of the spectrometer head, which is described in this report, a separate battery pack, and a lap- top computer with the appropriate interface to the spectrometer head

  11. DN-12 time of flight neutron spectrometer for investigation of structure and dynamics of microsamples

    International Nuclear Information System (INIS)

    Savenko, B.N.; Aksenov, V.L.; Balagurov, A.M.; Kozlenko, D.P.; Sheptyakov, D.V.

    1999-01-01

    DN-12 time of flight neutron spectrometer operating at IBR-2 high flux pulsed reactor at FLNP JINR, Dubna, Russia is described. It is designed for experiments with microsamples in wide range of temperatures and pressures. DN-12 allows to perform neutron diffraction experiments at temperatures down to 15 K and pressures up to 7 Gpa and inelastic incoherent scattering experiments (with samples which have large incoherent neutron scattering cross section) at pressures up to 5 GPa with sapphire anvil high pressure cells. The parameters of the spectrometer, recent results and future prospects are reviewed. (author)

  12. A neutron time of flight spectrometer appropriate for D-T plasma diagnostics

    International Nuclear Information System (INIS)

    Elevant, T.

    1984-02-01

    A neutron time-of-flight spectrometer with 2 m flight path for diagnostics of deuterium plasmas in JET is presently under construction. An upgrade of this spectrometer to make it appropriate for 14-MeV neutron spectroscopy is presented here. It is suggested to use backscattering in a deuterium based scintillator. The flight path length is 1-2 m and the efficiency is of the order of 2.10 -5 cm -5 . Results from test of principle are presented with estimates for neutron and gamma backgrounds

  13. Development of a compact magnetic proton recoil spectrometer for measurement of deuterium-tritium neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jianfu, E-mail: zhangjfu@gmail.com; Ouyang, Xiaoping; Zhang, Xianpeng [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Northwest Institute of Nuclear Technology, Xi’an 710024 (China); Qiu, Suizheng, E-mail: szqiu@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Zhang, Guoguang [Applied Institute of Nuclear Technology, China Institute of Atomic Energy, Beijing 102413 (China); Ruan, Jinlu; Zhang, Xiaodong; Yang, Shaohua; Song, Jiwen; Liu, Linyue; Li, Hongyun [Northwest Institute of Nuclear Technology, Xi’an 710024 (China)

    2015-12-15

    A new compact magnetic proton recoil (MPR) neutron spectrometer has been designed for precise measurement of deuterium-tritium (DT) neutrons. This design is presented emphasizing the magnetic analyzing system, which is based on a compact quadrupole-dipole (QD) electromagnet. The focal plane detector (FPD) is also discussed with respect to application for the next step. The characteristics of the MPR spectrometer were calculated by using Monte Carlo simulation. A preliminary experiment was performed to test the magnetic analyzing system and the proton images of the FPD. Since the QD electromagnet design allows for a larger foil thickness and solid angle to be utilized, the MPR spectrometer defined in this paper can achieve neutron detection efficiency more than 5 × 10{sup −7} at an energy resolution of 1.5% for measuring DT neutrons.

  14. A compact neutron spectrometer for characterizing inertial confinement fusion implosions at OMEGA and the NIF.

    Science.gov (United States)

    Zylstra, A B; Gatu Johnson, M; Frenje, J A; Séguin, F H; Rinderknecht, H G; Rosenberg, M J; Sio, H W; Li, C K; Petrasso, R D; McCluskey, M; Mastrosimone, D; Glebov, V Yu; Forrest, C; Stoeckl, C; Sangster, T C

    2014-06-01

    A compact spectrometer for measurements of the primary deuterium-tritium neutron spectrum has been designed and implemented on the OMEGA laser facility [T. Boehly et al., Opt. Commun. 133, 495 (1997)]. This instrument uses the recoil spectrometry technique, where neutrons produced in an implosion elastically scatter protons in a plastic foil, which are subsequently detected by a proton spectrometer. This diagnostic is currently capable of measuring the yield to ~±10% accuracy, and mean neutron energy to ~±50 keV precision. As these compact spectrometers can be readily placed at several locations around an implosion, effects of residual fuel bulk flows during burn can be measured. Future improvements to reduce the neutron energy uncertainty to ±15-20 keV are discussed, which will enable measurements of fuel velocities to an accuracy of ~±25-40 km/s.

  15. The design of a constant wavelength ultra small angle neutron scattering spectrometer

    International Nuclear Information System (INIS)

    Peng Mei; Chen Liang; Chen Yanzhou; Sun Liangwei

    2012-01-01

    In order to carry out the research of constant wavelength ultra small angle neutron scattering spectrometer (USANS), the design principle is studied in this paper base on relevant information from international laboratories. The main components are designed and calculated by using the Simres and NOP codes, and analytic method. The channel-cut crystal for monochromator and analyzer, and the pre-monochromator are designed, and minimum Q of spectrometer is calculated. The results indicate that width of Darwin plat affects the minimum Q of spectrometer, the angle resolution of reflectivity planes selected in the design can ensure a Q resolution in 10 -5 order. After the monochromatic neutron guide, a vertical focus monochromator does not seem to increase neutron flux at the sample stage, to simplify the monochromator structure and its manufacturing process, we propose to use un-focus pre-monochromator after the monochromatic neutron guide. (authors)

  16. Fusion neutron energy spectra measured by time-of-flight spectrometers

    CERN Document Server

    Elevant, T

    2002-01-01

    Evaluation of measured neutron energy spectra provides information on the central ion velocity distribution; e.g. ion temperature and fast ions induced by NBI- or ICR-heating and on impurity content in fusion grade plasmas. Two self-contained high-energy resolution time-of-flight neutron spectrometers have been used at the JET- and JT-60U tokamaks during DD-operation. In the spectrometers, each neutron undergoes (n, p) elastic scattering in two sets of hydrogen based scintillators. Elapsed time between the two scatter events is measured and the energy of the neutron is evaluated. Interpretation of acquired data together with results obtained from other diagnostics yields information on central plasma parameters. Deduced ion temperatures, fast ion fractional contributions during auxiliary NBI- and ICR-heating and impurity content is presented. In general, good agreement is obtained between neutron data and data from other diagnostics.

  17. A fan analyzer of neutron beam polarization on the spectrometer REMUR at the pulsed reactor IBR-2

    International Nuclear Information System (INIS)

    Ul'yanov, V.A.; Pusenkov, V.M.; Pleshanov, N.K.

    2004-01-01

    The new spectrometer of polarized neutrons REMUR has been created and put in operation at the Frank Laboratory of Neutron Physics (JINR, Dubna). The spectrometer is dedicated to investigations of multilayer structures and surfaces by registering the reflection of polarized neutrons and of the inhomogeneous state of solid matter by measuring the small-angle scattering of polarized neutrons. The spectrometer's working range of neutron wavelengths is 1.5-10 Angstroem. The spectrometer is equipped with a linear position-sensitive detector and a focused supermirror polarization analyzer (the fan-like polarization analyzer) with a solid angle of polarized neutron detection of 2.2·10 -4 rad. This paper describes the design and the principle of operation of the fan analyzer of neutron polarization together with the results of the fan tests on a polarized neutron beam

  18. Systematic determination of the JET absolute neutron yield using the MPR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kronborg-Pettersson, N

    2003-04-01

    This thesis describes the first high-statistics systematic analysis of JET neutron yield and rate measurements obtained by using data acquired with the Magnetic Proton Recoil (MPR) neutron spectrometer. The neutron yield and rate were determined by using the count-rate from the MPR neutron spectrometer together with neutron profile information from other neutron diagnostic systems. This has previously been done manually for a few pulses. To be able to do this in a more systematic way a part of the neutron spectrum evaluation code was extracted and put into a separate custom-made program and modifications were done to extract sets of MPR data automatically. The codes have been used for analysis of a large set of pulses from the deuterium-tritium campaign at JET in 1997. Several results were obtained, the most significant of which was the clear improvement seen when neutron profile corrections were applied. Neutron yield-rates derived from MPR count-rate are shown to be in excellent agreement with other JET neutron diagnostic data.

  19. Superconducting Gamma/Neutron Spectrometer Task 1 Completion Report Evaluation of Candidate Neutron-Sensitive Materials

    CERN Document Server

    Bell, Z W

    2002-01-01

    A review of the scientific literature regarding boron- and lithium-containing compounds was completed. Information such as Debye temperature, heat capacity, superconductivity properties, physical and chemical characteristics, commercial availability, and recipes for synthesis was accumulated and evaluated to develop a list of neutron-sensitive materials likely to perform properly in the spectrometer. The best candidate borides appear to be MgB sub 2 (a superconductor with T sub c = 39 K), B sub 6 Si, B sub 4 C, and elemental boron; all are commercially available. Among the lithium compounds are LiH, LiAl, Li sub 1 sub 2 Si sub 7 , and Li sub 7 Sn sub 2. These materials have or are expected to have high Debye temperatures and sufficiently low heat capacities at 100 mK to produce a useful signal. The responses of sup 1 sup 0 B and sup 6 Li to a fission neutron spectrum were also estimated. These demonstrated that the contribution of scattering events is no more than 3% in a boron-based system and 1.5% in a lith...

  20. A new small-angle neutron scattering spectrometer at China Mianyang research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Mei, E-mail: pm740509@163.com; Sun, Liangwei; Chen, Liang; Sun, Guangai; Chen, Bo; Xie, Chaomei; Xia, Qingzhong; Yan, Guanyun; Tian, Qiang; Huang, Chaoqiang; Pang, Beibei; Zhang, Ying; Wang, Yun; Liu, Yaoguang; Kang, Wu; Gong, Jian

    2016-02-21

    A new pinhole small-angle neutron scattering (SANS) spectrometer, installed at the cold neutron source of the 20 MW China Mianyang Research Reactor (CMRR) in the Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, has been put into use since 2014. The spectrometer is equipped with a multi-blade mechanical velocity selector, a multi-beam collimation system, and a two-dimensional He-3 position sensitive neutron detector. The q-range of the spectrometer covers from 0.01 nm{sup −1} to 5.0 nm{sup −1}. In this paper, the design and characteristics of the SANS spectrometer are described. The q-resolution calculations, together with calibration measurements of silver behenate and a dispersion of nearly monodisperse poly-methyl-methacrylate nanoparticles indicate that our SANS spectrometer has a good performance and is now in routine service. - Highlights: • A new SANS spectrometer has been put into use since 2014 in China. • One MBR selector possesses a higher resolution compared with traditional selector is used. • The spectrometer has a good performance and is now in routinely service.

  1. A new small-angle neutron scattering spectrometer at China Mianyang research reactor

    International Nuclear Information System (INIS)

    Peng, Mei; Sun, Liangwei; Chen, Liang; Sun, Guangai; Chen, Bo; Xie, Chaomei; Xia, Qingzhong; Yan, Guanyun; Tian, Qiang; Huang, Chaoqiang; Pang, Beibei; Zhang, Ying; Wang, Yun; Liu, Yaoguang; Kang, Wu; Gong, Jian

    2016-01-01

    A new pinhole small-angle neutron scattering (SANS) spectrometer, installed at the cold neutron source of the 20 MW China Mianyang Research Reactor (CMRR) in the Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, has been put into use since 2014. The spectrometer is equipped with a multi-blade mechanical velocity selector, a multi-beam collimation system, and a two-dimensional He-3 position sensitive neutron detector. The q-range of the spectrometer covers from 0.01 nm −1 to 5.0 nm −1 . In this paper, the design and characteristics of the SANS spectrometer are described. The q-resolution calculations, together with calibration measurements of silver behenate and a dispersion of nearly monodisperse poly-methyl-methacrylate nanoparticles indicate that our SANS spectrometer has a good performance and is now in routine service. - Highlights: • A new SANS spectrometer has been put into use since 2014 in China. • One MBR selector possesses a higher resolution compared with traditional selector is used. • The spectrometer has a good performance and is now in routinely service.

  2. Neutron spectra produced by moderating an isotopic neutron source

    International Nuclear Information System (INIS)

    Carrillo Nunnez, Aureliano; Vega Carrillo, Hector Rene

    2001-01-01

    A Monte Carlo study has been carried out to determine the neutron spectra produced by an isotopic neutron source inserted in moderating media. Most devices used for radiation protection have a response strongly dependent on neutron energy. ISO recommends several neutron sources and monoenergetic neutron radiations, but actual working situations have broad spectral neutron distributions extending from thermal to MeV energies, for instance, near nuclear power plants, medical applications accelerators and cosmic neutrons. To improve the evaluation of the dosimetric quantities, is recommended to calibrate the radiation protection devices in neutron spectra which are nearly like those met in practice. In order to complete the range of neutron calibrating sources, it seems useful to develop several wide spectral distributions representative of typical spectra down to thermal energies. The aim of this investigation was to use an isotopic neutron source in different moderating media to reproduce some of the neutron fields found in practice. MCNP code has been used during calculations, in these a 239PuBe neutron source was inserted in H2O, D2O and polyethylene moderators. Moderators were modeled as spheres and cylinders of different sizes. In the case of cylindrical geometry the anisotropy of resulting neutron spectra was calculated from 0 to 2 . From neutron spectra dosimetric features were calculated. MCNP calculations were validated by measuring the neutron spectra of a 239PuBe neutron source inserted in a H2O cylindrical moderator. The measurements were carried out with a multisphere neutron spectrometer with a 6LiI(Eu) scintillator. From the measurements the neutron spectrum was unfolded using the BUNKIUT code and the UTA4 response matrix. Some of the moderators with the source produce a neutron spectrum close to spectra found in actual applications, then can be used during the calibration of radiation protection devices

  3. Double difference method in deep inelastic neutron scattering on the VESUVIO spectrometer

    International Nuclear Information System (INIS)

    Andreani, C.; Colognesi, D.; Degiorgi, E.; Filabozzi, A.; Nardone, M.; Pace, E.; Pietropaolo, A.; Senesi, R.

    2003-01-01

    The principles of the Double Difference (DD) method, applied to the neutron spectrometer VESUVIO, are discussed. VESUVIO, an inverse geometry spectrometer operating at the ISIS pulsed neutron source in the eV energy region, has been specifically designed to measure the single particle dynamical properties in condensed matter. The width of the nuclear resonance of the absorbing filter, used for the neutron energy analysis, provides the most important contribution to the energy resolution of the inverse geometry instruments. In this paper, the DD method, which is based on a linear combination of two measurements recorded with filter foils of the same resonance material but of different thickness, is shown to improve significantly the instrumental energy resolution, as compared with the Single Difference (SD) method. The asymptotic response functions, derived through Monte-Carlo simulations for polycrystalline Pb and ZrH 2 samples, are analysed in both DD and SD methods, and compared with the experimental ones for Pb sample. The response functions have been modelled for two distinct experimental configurations of the VESUVIO spectrometer, employing 6 Li-glass neutron detectors and NaI γ detectors revealing the γ-ray cascade from the (n,γ) reaction, respectively. The DD method appears to be an effective experimental procedure for Deep Inelastic Neutron Scattering measurements on VESUVIO spectrometer, since it reduces the experimental resolution of the instrument in both 6 Li-glass neutron detector and γ detector configurations

  4. 7Li neutron-induced elastic scattering cross section measurement using a slowing-down spectrometer

    Directory of Open Access Journals (Sweden)

    Heusch M.

    2010-10-01

    Full Text Available A new integral measurement of the 7Li neutron induced elastic scattering cross section was determined in a wide neutron energy range. The measurement was performed on the LPSC-PEREN experimental facility using a heterogeneous graphite-LiF slowing-down time spectrometer coupled with an intense pulsed neutron generator (GENEPI-2. This method allows the measurement of the integral elastic scattering cross section in a slowing-down neutron spectrum. A Bayesian approach coupled to Monte Carlo calculations was applied to extract naturalC, 19F and 7Li elastic scattering cross sections.

  5. The small angle neutron scattering spectrometer at the Budapest research reactor

    International Nuclear Information System (INIS)

    Retfalvi, E.; Almasy, L.; Toeroek, Gy.; Len, A.; Rosta, L.

    2001-01-01

    The reinstallation of the Small Angle Neutron Scattering spectrometer (named 'Yellow Submarine') at the Budapest Research Reactor has been finished in winter 2001. Parallel to the installation of a liquid hydrogen cold source, the guide system of the spectrometer was also rebuilt to a more optimized geometry. The old natural Ni-coated guide sections of 2.5x10 cm 2 after the velocity selector have been replaced by a new supermirror coated curved neutron guide with 4x4 cm 2 cross section. The neutron flux of the upgraded spectrometer is much higher. The beam is formed by a fixed length collimator tube and monitored by a fission chamber. (R.P.)

  6. Development and Characterization of a High Sensitivity Segmented Fast Neutron Spectrometer (FaNS-2).

    Science.gov (United States)

    Langford, T J; Beise, E J; Breuer, H; Heimbach, C R; Ji, G; Nico, J S

    2016-01-01

    We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and 3 He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a 3 He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron fluxes. A main goal of its design is to study comparatively low neutron fluxes, such as cosmogenic neutrons at the Earth's surface, in an underground environment, or from low-activity neutron sources. In this paper, we present details of its design and construction as well as its characterization with a calibrated 252 Cf source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected monoenergetic neutron spectra are unfolded using a Singular Value Decomposition method, demonstrating a 5% energy resolution at 14 MeV. Finally, we discuss plans for measuring the surface and underground cosmogenic neutron spectra with FaNS-2.

  7. HYSPEC : A CRYSTAL TIME OF FLIGHT HYBRID SPECTROMETER FOR THE SPALLATION NEUTRON SOURCE.

    Energy Technology Data Exchange (ETDEWEB)

    SHAPIRO,S.M.; ZALIZNYAK,I.A.

    2002-12-30

    This document lays out a proposal by the Instrument Development Team (IDT) composed of scientists from leading Universities and National Laboratories to design and build a conceptually new high-flux inelastic neutron spectrometer at the pulsed Spallation Neutron Source (SNS) at Oak Ridge. This instrument is intended to supply users of the SNS and scientific community, of which the IDT is an integral part, with a platform for ground-breaking investigations of the low-energy atomic-scale dynamical properties of crystalline solids. It is also planned that the proposed instrument will be equipped with a polarization analysis capability, therefore becoming the first polarized beam inelastic spectrometer in the SNS instrument suite, and the first successful polarized beam inelastic instrument at a pulsed spallation source worldwide. The proposed instrument is designed primarily for inelastic and elastic neutron spectroscopy of single crystals. In fact, the most informative neutron scattering studies of the dynamical properties of solids nearly always require single crystal samples, and they are almost invariably flux-limited. In addition, in measurements with polarization analysis the available flux is reduced through selection of the particular neutron polarization, which puts even more stringent limits on the feasibility of a particular experiment. To date, these investigations have mostly been carried out on crystal spectrometers at high-flux reactors, which usually employ focusing Bragg optics to concentrate the neutron beam on a typically small sample. Construction at Oak Ridge of the high-luminosity spallation neutron source, which will provide intense pulsed neutron beams with time-averaged fluxes equal to those at medium-flux reactors, opens entirely new opportunities for single crystal neutron spectroscopy. Drawing upon experience acquired during decades of studies with both crystal and time-of-flight (TOF) spectrometers, the IDT has developed a conceptual

  8. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  9. A Time of flight spectrometer for measurements of double differential neutron scattering cross sections

    International Nuclear Information System (INIS)

    Padron, I.; Dominguez, O.; Sarria, P. Sandin, C.

    1996-01-01

    The time -of-Flight neutron spectrometry technique by associated particle method was improved using a D-T neutron generator at Laboratory of Nuclear Analysis. This technique was implemented for double differential cross section measurements and supported by the IAEA Project CUB/01/005. An stilbene scintillation detector (dia=100 mm, length=50 mm) was used as principal neutron detector detector and was situated outside a hole in the concrete wall. This way the fligth path was extended and the scattered neutron cone accurate collimated throught the 2 m concrete wall. For the associated particle α detection a thin plastic NE-102 scint illator was used, as well as, two scintilation detectors and a long counter for the neutron flux monitoring. In this TOF neutron spectrometer (3.40 m flight path) a 1.7 nseg. temporal resolution was obtained

  10. The triple-axis neutron spectrometer KANDI III and measurement of phonons in copper

    International Nuclear Information System (INIS)

    Melamud, M.; Pinto, H.; Shaked, H.

    1976-12-01

    The acoustic phonon dispersion relations of copper were measured using the recently installed triple-axis neutron spectrometer KANDI III. A description of KANDI III and its peripherals is given in this work. The theory of dispersion relations and their measurement using neutron inelastic diffraction are briefly discussed. Raw data and results for copper are presented and compared with the data and results found in the literature

  11. The use of a Bonner sphere spectrometer for determining the spatial distribution of neutron fields

    CERN Document Server

    Varela, A; Jimenez, F; Calvillo, J

    1999-01-01

    The directional properties of a modified Bonner-type spectrometer, using spheres with a radial hole, are described in this report. It was found that spheres with these modifications are able to detect the spatial distribution of a neutron field. The neutrons were generated by the sup 9 Be(d,n) sup 1 sup 0 B reaction, produced by bombarding a thick Be target with 4 MeV deutrons provided by a tandem Van de Graaff accelerator.

  12. Thermal neutron spectra measurements in IEAR-1 Reactor, by using a crystal spectrometer

    International Nuclear Information System (INIS)

    Fulfaro, R.; Figueiredo Neto, A.M.; Stasiulevicius, E.; Vinhas, L.A.

    1975-01-01

    The thermal neutron spectrum of the IEN Argonauta reactor has been measured in the wavelength from 0.7 to 1.9A, using a neutron crystal spectrometer. An aluminium single crystal, in transmission, was used as monochromator. The aluminium crystal reflectivity employed in the analysis of the data was calculated for the first five permitted orders. An effective absorption coefficient of the crystal was used to perform the calculations instead of the macroscopic cross section of the element

  13. REFSANS: Reflectometer and evanescent wave small angle neutron spectrometer

    Directory of Open Access Journals (Sweden)

    Jean-François Moulin

    2015-08-01

    Full Text Available The horizontal reflectometer REFSANS, operated by GEMS, Helmholtz-Zentrum Geesthacht, was designed to enable specular reflectometry as well as grazing incidence neutron scattering studies of both solid samples and liquid-air interfaces.

  14. Fusion Power Measurement Using a Combined Neutron Spectrometer-Camera System at ITER

    International Nuclear Information System (INIS)

    Sjoestrand, Henrik; Sunden, E. Andersson; Conroy, S.; Ericsson, G.; Johnson, M. Gatu; Giacomelli, L.; Hellesen, C.; Hjalmarsson, A.; Ronchi, E.; Weiszflog, M.; Kaellne, J.

    2008-01-01

    A central task for fusion plasma diagnostics is to measure the 2.5 and 14 MeV neutron emission rate in order to determine the fusion power. A new method for determining the neutron yield has been developed at JET. It makes use of the magnetic proton recoil neutron spectrometer and a neutron camera and provides the neutron yield with small systematic errors. At ITER a similar system could operate if a high-resolution, high-performance neutron spectrometer similar to the MPR was installed. In this paper, we present how such system could be implemented and how well it would perform under different assumption of plasma scenarios and diagnostic capabilities. It is found that the systematic uncertainty for using such a system as an absolute calibration reference is as low as 3% and hence it would be an excellent candidate for the calibration of neutron monitors such as fission chambers. It is also shown that the system could provide a 1 ms time resolved estimation of the neutron rate with a total uncertainty of 5%

  15. Scintillation spectrometer system for measuring fast-neutron spectra in beam geometry

    International Nuclear Information System (INIS)

    Simons, G.G.; Larson, J.M.; Reynolds, R.S.

    1977-05-01

    A high-energy liquid-organic scintillation spectrometer system is described. This spectrometer was developed to measure neutron spectra in extracted beams from zero-power fast reactors. The highly efficient NE-213 scintillation solution was used as the neutron detection medium. Identification and removal of gamma-ray-induced events was accomplished using electronic pulse shape discrimination. Instrumentation used to process the discrete pulses stemming from neutron and gamma-ray interactions, within the scintillation solution, is described in detail. Evaluation of the system's performance is discussed for a gamma-ray discrimination ratio of nominally 1000:1, a total countrate of 3000 cps, and a dynamic range corresponding to neutron energies from 1 to 10 MeV. Operation above 10 MeV is certainly possible. However, since the neutron flux above 10 MeV was negligible in the radiation fields of interest in this work, the operating characteristics of the spectrometer were not evaluated above 10 MeV. Neutron spectra are reported for extracted beam measurements made on ZPPR assembly 4, phase 2

  16. Experimental characterization of a prototype secondary spectrometer for vertically scattering multiple energy analysis at cold-neutron triple axis spectrometers

    DEFF Research Database (Denmark)

    Toft-Petersen, Rasmus; Groitl, Felix; Kure, Mathias

    2016-01-01

    A thorough experimental characterization of a multiplexing backend with multiple energy analysis on a cold-neutron triple axis spectrometer (cTAS) is presented. The prototype employs two angular segments (2 theta-segments) each containing five vertically scattering analyzers (energy channels...... to the energy resolution of a standard cTAS. The dispersion relation of the antiferromagnetic excitations in MnF2 has been mapped out by performing constant energy transfer maps. These results show that the tested setup is virtually spurion free. In addition, focusing effects due to (mis...

  17. The spectrometer PERKEO III and the decay of free neutrons; Das Spektrometer PERKEO III und der Zerfall des freien Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Maerkisch, B.M.

    2006-10-18

    The Standard Model of particle physics describes neutron decay with three parameters. In contrast to that, a multitude of observables are accessible experimentally. With precision measurements sensitive tests of the Standard Model are thus possible. The neutron decay spectrometer PERKEO III was designed and built as part of this work. It will replace its predecessor PERKEO II, which has reached its systematical and statistical limits. With the new instrument measurements with continuous and pulsed neutron beams become feasible. This either provides an increase in statistics of up to two orders of magnitude, or eliminates the two major instrument specific sources of systematical corrections. In our first measurement in winter 2006/2007, the available event rate will be used to determine weak magnetism from the electron asymmetry A. Previously, this value was not statistically accessible in neutron decay. Systematics are analyzed with the help of our measurement with PERKEO II. For this measurement PERKEO III will be installed at the neutron guide H113 at the Institute Laue-Langevin, Grenoble. The neutron beam from this guide is characterized and a model is given, which allows the rapid calculation of beam profiles and absolute event rates from such a beam. In preparation of a future neutron decay instrument the reflective properties of two non-magnetic neutron mirrors were measured. (orig.)

  18. Computer-controlled neutron time-of-flight spectrometer. Part II

    Energy Technology Data Exchange (ETDEWEB)

    Merriman, S.H.

    1979-12-01

    A time-of-flight spectrometer for neutron inelastic scattering research has been interfaced to a PDP-15/30 computer. The computer is used for experimental data acquisition and analysis and for apparatus control. This report was prepared to summarize the functions of the computer and to act as a users' guide to the software system.

  19. Simulations of chopper jitter at the LET neutron spectrometer at the ISIS TS2

    DEFF Research Database (Denmark)

    Klenø, Kaspar Hewitt; Lefmann, Kim; Willendrup, Peter Kjær

    2014-01-01

    The effect of uncertainty in chopper phasing (jitter) has been investigated for the high-resolution time-of-flight spectrometer LET at the ISIS second target station. The investigation is carried out using virtual experiments, with the neutron simulation package McStas, where the chopper jitter i...

  20. The monochromatic imaging mode of a RITA-type neutron spectrometer

    DEFF Research Database (Denmark)

    Bahl, C.R.H.; Andersen, P.; Klausen, S.N.

    2004-01-01

    The imaging monochromatic mode of a neutron spectrometer with a multi-bladed RITA analyser system is so far unexplored. We present analytical calculations that define the mode. It is shown that the mode can be realised for PG (002) analyser crystals, from incident energies of about 3.2 meV and up...

  1. DNS: Diffuse scattering neutron time-of-flight spectrometer

    Directory of Open Access Journals (Sweden)

    Yixi Su

    2015-08-01

    Full Text Available DNS is a versatile diffuse scattering instrument with polarisation analysis operated by the Jülich Centre for Neutron Science (JCNS, Forschungszentrum Jülich GmbH, outstation at the Heinz Maier-Leibnitz Zentrum (MLZ. Compact design, a large double-focusing PG monochromator and a highly efficient supermirror-based polarizer provide a polarized neutron flux of about 107 n cm-2 s-1. DNS is used for the studies of highly frustrated spin systems, strongly correlated electrons, emergent functional materials and soft condensed matter.

  2. Simulation report for neutron guide and spectrometer layout at HANARO

    International Nuclear Information System (INIS)

    Cho, S. J.; Cho, Y. G.; Ryu, J. S.; Seong, B. S.; Lee, C. H.; Shin, J. W.

    2006-01-01

    A project called 'infrastructure construction for cold neutron research and utilization technique development' was launched in KAERI in July 2003, in order to raise a domestic basic science with an international level and elevate a international competitiveness for the bio-, nano- and informatics technology area. At the end of this project, 3 new instruments and 3 instruments to be moved will be installed in the guide hall. In order to accomplish this project until 2008, guide simulation should be performed for an effective use of expensive neutron to meet the requirements such as wavelengths and type of instruments, experimental space, interferences with other instruments

  3. Cold-neutron multi-chopper spectrometer for MLF, J-PARC

    International Nuclear Information System (INIS)

    Nakajima, Kenji; Kajimoto, Ryoich; Nakamura, Mistutaka; Arai, Masatoshi; Sato, Taku J.; Osakabe, Toyotaka; Matsuda, Masaaki; Metoki, Naoto; Kakurai, Kazuhisa; Itoh, Shinichi

    2005-01-01

    We are planning to construct a cold-neutron multi-chopper spectrometer for a new spallation neutron source at Materials and Life Science Facility (MLF) at J-PARC, which is dedicated to investigation of low energy excitations and quasi-elastic excitations in the field of solid state physics, chemistry, materials science, soft matter science and biomaterial science. The planned spectrometer will be installed at a H 2 -coupled moderator and will be equipped with a pulse-shaping disk-chopper in addition to a monochromating disk-chopper, and realizes both high-energy resolution (ΔE/E i ≥1%) and high-intensity (one order of magnitude higher than the present state-of-the-art chopper spectrometers)

  4. Comments on 'Design optimization of a small-angle neutron scattering spectrometer'

    International Nuclear Information System (INIS)

    Mildner, D.F.R.

    1990-01-01

    Margaca, Falcao, Salgado and Carvahlo have recently discussed the design parameters of a small-angle scattering spectrometer. They claim to have shown that the instrument can be optimized for constant angular resolution and a fixed neutron source area, such that the detector count rate is higher than that obtained with a spectrometer optimized for a fixed total length and having the same angular resolution. They also claim that the relative gain in intensity depends upon the size of the neutron emitting surface available to the spectrometer. The initial assumptions made by the authors are too constrained to be generally applicable and therefore misleading conclusions could be drawn, and in fact the equal path length arrangement is optimum. (orig.)

  5. Radiological Shielding Design for the Neutron High-Resolution Backscattering Spectrometer EMU at the OPAL Reactor

    Science.gov (United States)

    Ersez, Tunay; Esposto, Fernando; Souza, Nicolas R. de

    2017-09-01

    The shielding for the neutron high-resolution backscattering spectrometer (EMU) located at the OPAL reactor (ANSTO) was designed using the Monte Carlo code MCNP 5-1.60. The proposed shielding design has produced compact shielding assemblies, such as the neutron pre-monochromator bunker with sliding cylindrical block shields to accommodate a range of neutron take-off angles, and in the experimental area - shielding of neutron focusing guides, choppers, flight tube, backscattering monochromator, and additional shielding elements inside the Scattering Tank. These shielding assemblies meet safety and engineering requirements and cost constraints. The neutron dose rates around the EMU instrument were reduced to < 0.5 µSv/h and the gamma dose rates to a safe working level of ≤ 3 µSv/h.

  6. Design Principle of A Small Angle Neutron Scattering Spectrometer. Vol. 2

    International Nuclear Information System (INIS)

    Ashry, A.

    1996-01-01

    The design principle of a small angle neutron scattering (SANS) spectrometer is based on producing monochromatic neutron bursts using two phased rotors. The rotors have a number of slots to achieve the highly available intensity of monoenergetic neutrons at the required resolution. The design principle was applied to improve the performance of the pulsed monochromatic double rotor system at ET-RR-1 to operate as SANS spectrometer. It is shown that for rotors having 19 slots each with radius of curvature 96.8 cm, the intensity gain factor is 13. The proposed SANS spectrometer could cover the neutron wavelength range from 2 A ο up to 6 A ο through small angles of scattering from 5 x 10 -3 rad. to 0.1 rad. i.e, the scattering wavevector transfer between 0.6 A ο-1 and 0.01 A ο-1 . The maximum neutron flux density on the specimen is 5 x 10 5 n cm -2 s -1 . 8 figs

  7. Fast Neutron Detection Using Pixelated CdZnTe Spectrometers

    Science.gov (United States)

    Streicher, Michael; Goodman, David; Zhu, Yuefeng; Brown, Steven; Kiff, Scott; He, Zhong

    2017-07-01

    Fast neutrons are an important signature of special nuclear materials (SNMs). They have a low natural background rate and readily penetrate high atomic number materials that easily shield gamma-ray signatures. Therefore, they provide a complementary signal to gamma rays for detecting shielded SNM. Scattering kinematics dictate that a large nucleus (such as Cd or Te) will recoil with small kinetic energy after an elastic collision with a fast neutron. Charge carrier recombination and quenching further reduce the recorded energy deposited. Thus, the energy threshold of CdZnTe detectors must be very low in order to sense the small signals from these recoils. In this paper, the threshold was reduced to less than 5 keVee to demonstrate that the 5.9-keV X-ray line from 55Fe could be separated from electronic noise. Elastic scattering neutron interactions were observed as small energy depositions (less than 20 keVee) using digitally sampled pulse waveforms from pixelated CdZnTe detectors. Characteristic gamma-ray lines from inelastic neutron scattering were also observed.

  8. Tests of the space gamma spectrometer prototype at the JINR experimental facility with different types of neutron generators

    Science.gov (United States)

    Litvak, M. L.; Vostrukhin, A. A.; Golovin, D. V.; Dubasov, P. V.; Zontikov, A. O.; Kozyrev, A. S.; Krylov, A. R.; Krylov, V. A.; Mitrofanov, I. G.; Mokrousov, M. I.; Repkin, A. N.; Timoshenko, G. N.; Udovichenko, K. V.; Shvetsov, V. N.

    2017-07-01

    The results of the tests of the HPGe gamma spectrometer performed with a planetary soil model and different types of pulse neutron generators are presented. All measurements have been performed at the experimental nuclear planetary science facility (Joint Institute for Nuclear Research) for the physical calibration of active gamma and neutron spectrometers. The aim of the study is to model a space experiment on determining the elemental composition of Martian planetary matter by neutron-induced gamma spectroscopy. The advantages and disadvantages of a gas-filled neutron generator in comparison with a vacuum-tube neutron generator are examined.

  9. Upgrade of neutron energy spectrometer with single multilayer bonner sphere using onion-like structure

    International Nuclear Information System (INIS)

    Mizukpshi, Tomoaki; Watanabe, Kenichi; Yamazaki, Atsushi; Uritan, Akira; Iguchi, Tetsuo; Ogata, Tomohiro; Muramatsu, Takashi

    2016-01-01

    In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type LiCaAlF6 (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. The fabricated detector shows excellent directional uniformity of the neutron sensitivity

  10. Upgrade of neutron energy spectrometer with single multilayer bonner sphere using onion-like structure

    Energy Technology Data Exchange (ETDEWEB)

    Mizukpshi, Tomoaki; Watanabe, Kenichi; Yamazaki, Atsushi; Uritan, Akira [Nagoya University, Nagoya (Japan); Iguchi, Tetsuo; Ogata, Tomohiro; Muramatsu, Takashi [Mitsubishi Heavy Industries Ltd., Kobe(Japan)

    2016-09-15

    In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type LiCaAlF6 (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

  11. The thin-foil magnetic proton recoil neutron spectrometer MPRu at JET

    International Nuclear Information System (INIS)

    Andersson Sunden, E.; Sjoestrand, H.; Conroy, S.; Ericsson, G.; Gatu Johnson, M.; Giacomelli, L.; Hellesen, C.; Hjalmarsson, A.; Ronchi, E.; Weiszflog, M.; Kaellne, J.; Gorini, G.; Tardocchi, M.; Combo, A.; Cruz, N.; Batista, A.; Pereira, R.; Fortuna, R.; Sousa, J.; Popovichev, S.

    2009-01-01

    Neutrons are produced in fusion energy experiments with both deuterium (D) and deuterium-tritium (DT) plasmas. Neutron spectroscopy is a valuable tool in the study of the underlying fuel ion populations. The magnetic proton recoil neutron spectrometer, originally installed at JET in 1996 for 14-MeV neutron measurements, has been upgraded, with the main aim of improving its signal-to-background ratio (S/B), making measurements of the 2.5-MeV neutron emission in D plasmas possible. The upgrade includes a new focal-plane detector, based on the phoswich technique and consequently less sensitive to background, and a new custom-designed digital data acquisition system based on transient recorder cards. Results from JET show that the upgraded MPRu can measure 2.5-MeV neutrons with S/B=5, an improvement by a factor of 50 compared with the original MPR. S/B of 2.8x10 4 in future DT experiments is estimated. The performance of the MPRu is exemplified with results from recent D plasma operations at JET, concerning both measurements with Ohmic, ion cyclotron resonance (ICRH) and neutral beam injection (NBI) plasma heating, as well as measurements of tritium burn-up neutrons. The upgraded instrument allows for 2.5-MeV neutron emission and deuterium ion temperature measurements in plasmas with low levels of tritium, a feature necessary for the ITER experiment.

  12. Neutron spectrometer for DD/DT burning ratio measurement in fusion experimental reactor

    International Nuclear Information System (INIS)

    Asai, Keisuke; Naoi, Norihiro; Iguchi, Tetsuo; Watanabe, Kenichi; Kawarabayashi, Jun; Nishitani, Takeo

    2006-01-01

    The most feasible fuels for a fusion reactor are D (Deuterium) and T (Tritium). DD and/or DT fusion reaction or nuclear burning reaction provides two kinds of neutrons, DD neutron and DT neutron, respectively. DD/DT burning ratio, which can be estimated by DD/DT neutron ratio in the burning plasma, is essential for burn control, alpha particle emission rate monitoring and tritium fuel cycle estimation. Here we propose a new neutron spectrometer for the absolute DD/DT burning ratio measurement. The system consists of a Proton Recoil Telescope (PRT) and a Time-of-Flight (TOF) technique. We have conducted preliminary experiments with a prototype detector and a DT neutron beam (φ20 mm) at the Fusion Neutronics Source, Japan Atomic Energy Agency (JAEA), to assess its basic performance. The detection efficiency obtained by the experiment is consistent with the calculation results in PRT, and sufficient energy resolution for the DD/DT neutron discrimination has been achieved in PRT and TOF. The validity of the Monte Carlo calculation has also been confirmed by comparing the experimental results with the calculation results. The design consideration of this system for use in ITER (International Thermonuclear Experimental Reactor) has shown that this system is capable of monitoring the line-integrated DD/DT burning ratio for the plasma core line of sight with the required measurement accuracy of 20% in the upper 4 decades of the ITER operation (fusion power: 100 kW-700 MW). (author)

  13. Choppers to optimise the repetition rate multiplication technique on a direct geometry neutron chopper spectrometer

    DEFF Research Database (Denmark)

    Vickery, Anette; Deen, P. P.

    2014-01-01

    In recent years the use of repetition rate multiplication (RRM) on direct geometry neutron spectrometers has been established and is the common mode of operation on a growing number of instruments. However, the chopper configurations are not ideally optimised for RRM with a resultant 100 fold flux...... in time resolution probed for a single European Spallation Source (ESS) period, which is ideal to probe complex relaxational behaviour. These two chopper configurations have been simulated for the Versatile Optimal Resolution direct geometry spectrometer, VOR, that will be built at ESS....

  14. On the use of a toroidal mirror to focus neutrons at the ILL neutron spin echo spectrometer IN15

    International Nuclear Information System (INIS)

    Hayes, C.; Alefeld, B.; Copley, J.R.D.

    1997-01-01

    The IN15 neutron spin echo spectrometer at the Institut Laue-Langevin (Grenoble) has been designed to accomodate a toroidal focusing mirror. This mirror will be used to increase the intensity at the sample position for measurements at long neutron wavelengths and to perform measurements in the low q-range (10 -3 angstrom -1 ). This paper summarizes the results of ray-tracing simulations for the toroidal mirror system. These calculations were performed in order to assess the effects of the neutron wavelength, gravitational fall, wavelength resolution and spherical aberrations on the quality of the focused beam. The gain in flux that can be expected from the focusing geometry is estimated. The recent installation and characterisation of the mirror is also briefly described

  15. The multiple disk chopper neutron time-of-flight spectrometer at NIST

    International Nuclear Information System (INIS)

    Altorfer, F.B.; Cook, J.C.; Copley, J.R.D.

    1995-01-01

    A highly versatile multiple disk chopper neutron time-of-flight spectrometer is being installed at the Cold Neutron Research Facility of the National institute of Standards and Technology. This new instrument will fill an important gap in the portfolio of neutron inelastic scattering spectrometers in North America. It will be used for a wide variety of experiments such as studies of magnetic and vibrational excitations, tunneling spectroscopy, and quasielastic neutron scattering investigations of local and translational diffusion. The instrument uses disk choppers to monochromate and pulse the incident beam, and the energy changes of scattered neutrons are determined from their times-of-flight to a large array of detectors. The disks and the guide have been designed to make the instrument readily adaptable to the specific performance requirements of experimenters. The authors present important aspects of the design, as well as estimated values of the flux at the sample and the energy resolution for elastic scattering. The instrument should be operational in 1996

  16. A portable and wide energy range semiconductor-based neutron spectrometer

    International Nuclear Information System (INIS)

    Hoshor, C.B.; Oakes, T.M.; Myers, E.R.; Rogers, B.J.; Currie, J.E.; Young, S.M.; Crow, J.A.; Scott, P.R.; Miller, W.H.; Bellinger, S.L.; Sobering, T.J.; Fronk, R.G.; Shultis, J.K.; McGregor, D.S.; Caruso, A.N.

    2015-01-01

    Hand-held instruments that can be used to passively detect and identify sources of neutron radiation—either bare or obscured by neutron moderating and/or absorbing material(s)—in real time are of interest in a variety of nuclear non-proliferation and health physics applications. Such an instrument must provide a means to high intrinsic detection efficiency and energy-sensitive measurements of free neutron fields, for neutrons ranging from thermal energies to the top end of the evaporation spectrum. To address and overcome the challenges inherent to the aforementioned applications, four solid-state moderating-type neutron spectrometers of varying cost, weight, and complexity have been designed, fabricated, and tested. The motivation of this work is to introduce these novel human-portable instruments by discussing the fundamental theory of their operation, investigating and analyzing the principal considerations for optimal instrument design, and evaluating the capability of each of the four fabricated spectrometers to meet the application needs.

  17. A portable and wide energy range semiconductor-based neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hoshor, C.B. [Department of Physics, University of Missouri, Kansas City, MO (United States); Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Myers, E.R.; Rogers, B.J.; Currie, J.E.; Young, S.M.; Crow, J.A.; Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, Manhattan, KS (United States); Fronk, R.G.; Shultis, J.K.; McGregor, D.S. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2015-12-11

    Hand-held instruments that can be used to passively detect and identify sources of neutron radiation—either bare or obscured by neutron moderating and/or absorbing material(s)—in real time are of interest in a variety of nuclear non-proliferation and health physics applications. Such an instrument must provide a means to high intrinsic detection efficiency and energy-sensitive measurements of free neutron fields, for neutrons ranging from thermal energies to the top end of the evaporation spectrum. To address and overcome the challenges inherent to the aforementioned applications, four solid-state moderating-type neutron spectrometers of varying cost, weight, and complexity have been designed, fabricated, and tested. The motivation of this work is to introduce these novel human-portable instruments by discussing the fundamental theory of their operation, investigating and analyzing the principal considerations for optimal instrument design, and evaluating the capability of each of the four fabricated spectrometers to meet the application needs.

  18. A neutron spectrometer based on the combination of time-of-flight and Larmor modulation

    International Nuclear Information System (INIS)

    Mulder, F.M.; Kreuger, R.; Grigoriev, S.V.; Kraan, W.H.; Rekveldt, M.Th.; Van Well, A.A.

    1999-01-01

    A study on the feasibility of neutron beam instrumentation that applies Larmor modulation for incoming, and time-of-flight for scattered wavelength determination (or vice versa) is currently under way at IRI. The instrument resulting from this combination can in principle measure quasi elastic and inelastic scattering with a flexible resolution and dynamic range. An important difference with current spectrometers is that there is no selection of neutron wavelengths for either the incoming beam (direct geometry) or scattered beam (inverted geometry). Therefore much of the available flux is used and there is no a priory selection of the energy transfer range and resolution. This instrument will be mainly applicable for quasi-elastic scattering and complex line shapes that are extended over a broad range in energy transfer. Line shapes can be measured directly in Fourier space, which is often advantageous. Due to signal to noise considerations, this instrument will be less suitable for the determination of weak, discrete energy transfer signals. A requirement for the Larmor modulator is that it can work with a white neutron beam. This can be realised for neutrons having a wavelength above ∼ 0.1 nm by use of 'adiabatic resonance π flippers'. This type of instrument may be applied at the future ESS pulsed neutron source in order to complement current spectrometers. (author)

  19. Improved performances of 36 m small-angle neutron scattering spectrometer BATAN in Serpong Indonesia

    International Nuclear Information System (INIS)

    Putra, Edy Giri Rachman; Bharoto; Santoso, Eddy; Ikram, Abarrul

    2009-01-01

    SMARTer, a 36 m small-angle neutron scattering (SANS) spectrometer owned by the National Nuclear Energy Agency of Indonesia (BATAN) was installed at the Neutron Scattering Laboratory (NSL) in Serpong, Indonesia. Lots of works on replacing, upgrading and improving the control system, experimental methods, data collection and reduction in the last two years have been carried out to optimize the performance of SMARTer. Some standard samples such as silver behenate, monodisperse polystyrene nanoparticle, porous silica and block copolymer PS-PEP film were measured for the inter-laboratory comparison.

  20. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    DEFF Research Database (Denmark)

    Bahl, Christian Robert Haffenden; Lefmann, Kim; Abrahamsen, Asger Bech

    2006-01-01

    to perform real inelastic neutron scattering experiments. We present the results from inelastic powder, single crystal dispersion and single crystal constant energy mapping experiments. The advantages and complications of performing these experiments are discussed along with a comparison between the imaging......Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator...

  1. The monochromatic imaging mode of a RITA-type neutron spectrometer

    DEFF Research Database (Denmark)

    Bahl, C.R.H.; Andersen, P.; Klausen, S.N.

    2004-01-01

    The imaging monochromatic mode of a neutron spectrometer with a multi-bladed RITA analyser system is so far unexplored. We present analytical calculations that define the mode. It is shown that the mode can be realised for PG (002) analyser crystals, from incident energies of about 3.2 meV and up......, allowing the important cases of 3.7, 5.0 and 13.7 meV. Due to beam divergence, the neutron rays from neighbouring analyser blades are found to overlap slightly. Hence, the optimal use of the monochromatic imaging mode would be found by employing an adjustable radial collimator to limit the spread...

  2. The very low angle detector for high-energy inelastic neutron scattering on the VESUVIO spectrometer

    International Nuclear Information System (INIS)

    Perelli Cippo, E.; Gorini, G.; Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Rhodes, N.J.; Schooneveld, E.M.

    2008-01-01

    The Very Low Angle Detector (VLAD) bank has been installed on the VESUVIO spectrometer at the ISIS spallation neutron source. The new device allows for high-energy inelastic neutron scattering measurements, at energies above 1 eV, maintaining the wave vector transfer lower than 10A -1 . This opens a still unexplored region of the kinematical (q,ω) space, enabling new and challenging experimental investigations in condensed matter. This paper describes the main instrumental features of the VLAD device, including instrument design, detector response, and calibration procedure

  3. The very low angle detector for high-energy inelastic neutron scattering on the VESUVIO spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Perelli Cippo, E.; Gorini, G.; Tardocchi, M. [Dipartimento di Fisica ' G. Occhialini' , Universita degli Studi di Milano-Bicocca, Piazza della Scienza 3, 20126 Milano (Italy); Pietropaolo, A. [Dipartimento di Fisica ' G. Occhialini' , CNISM-Universita degli Studi di Milano-Bicocca, Piazza della Scienza 3, 20126 Milano (Italy); NAST Center - Nanoscienze-Nanotecnologie-Strumentazione, Universita degli Studi di Roma Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy)], E-mail: antonino.pietropaolo@mib.infn.it; Andreani, C.; Senesi, R. [Dipartimento di Fisica and Centro NAST - Nanoscienze-Nanotecnologie-Strumentazione, Universita degli Studi di Roma Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy); Rhodes, N.J.; Schooneveld, E.M. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire 0QX OX11 (United Kingdom)

    2008-05-01

    The Very Low Angle Detector (VLAD) bank has been installed on the VESUVIO spectrometer at the ISIS spallation neutron source. The new device allows for high-energy inelastic neutron scattering measurements, at energies above 1 eV, maintaining the wave vector transfer lower than 10A{sup -1}. This opens a still unexplored region of the kinematical (q,{omega}) space, enabling new and challenging experimental investigations in condensed matter. This paper describes the main instrumental features of the VLAD device, including instrument design, detector response, and calibration procedure.

  4. A time-of-flight spectrometer for neutron diffraction under high pressure or at high temperature

    International Nuclear Information System (INIS)

    Roult, G.; Buevoz, J.L.

    1975-01-01

    For high pressure neutron diffraction studies (40 kilobars) the sample is placed in a very thick cell. In order to allow the neutron beam to go through the cell loosing as little intensity as possible, the inner part is kept solid while the external part has some windows facing the incident and reflected beam. The window dimensions are small (a few millimeters wide and a few centimeters long). There are two alternatives: to have the window either in a perpendicular plane or in a plane parallel to the axis. In the first case a fixed wavelength spectrometer can be used but the sample is small and the contribution of the cell to the diffraction pattern is relatively great. In the second case samples can be something like ten times greater and the cell contribution can be eliminated but a fixed wavelength spectrometer cannot be used. Thus the time-of-flight method is very convenient. The second alternative was chosen

  5. Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator

    International Nuclear Information System (INIS)

    Cremer, J. T.; Williams, D. L.; Fuller, M. J.; Gary, C. K.; Piestrup, M. A.; Pantell, R. H.; Feinstein, J.; Flocchini, R. G.; Boussoufi, M.; Egbert, H. P.; Kloh, M. D.; Walker, R. B.

    2010-01-01

    A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern-Gerlach gradient devices and compound material and magnetic refractive prisms.

  6. Inelastic neutron scattering using a crystal spectrometer on a pulsed source

    International Nuclear Information System (INIS)

    Carlile, C.J.; Williams, W.G.

    1981-03-01

    The method of measuring inelastic neutron scattering processes by using a crystal spectrometer on a pulsed source is described and compared with the chopper method. Comparable intensities and resolutions are predicted at incident energies approximately 1eV, with a copper monochromator, which corresponds to the highest incident energy at which a resolution < 1% can be obtained with a chopper instrument. Good performances at higher incident energies (approximately 2.3eV) are predicted for a crystal spectrometer using a beryllium monochromator. The main advantage of a crystal spectrometer is however that, in contrast to the chopper instrument, it does not impose any stringent phasing requirements with the source pulse. (author)

  7. Synthetic neutron camera and spectrometer in JET based on AFSI-ASCOT simulations

    Science.gov (United States)

    Sirén, P.; Varje, J.; Weisen, H.; Koskela, T.; contributors, JET

    2017-09-01

    The ASCOT Fusion Source Integrator (AFSI) has been used to calculate neutron production rates and spectra corresponding to the JET 19-channel neutron camera (KN3) and the time-of-flight spectrometer (TOFOR) as ideal diagnostics, without detector-related effects. AFSI calculates fusion product distributions in 4D, based on Monte Carlo integration from arbitrary reactant distribution functions. The distribution functions were calculated by the ASCOT Monte Carlo particle orbit following code for thermal, NBI and ICRH particle reactions. Fusion cross-sections were defined based on the Bosch-Hale model and both DD and DT reactions have been included. Neutrons generated by AFSI-ASCOT simulations have already been applied as a neutron source of the Serpent neutron transport code in ITER studies. Additionally, AFSI has been selected to be a main tool as the fusion product generator in the complete analysis calculation chain: ASCOT - AFSI - SERPENT (neutron and gamma transport Monte Carlo code) - APROS (system and power plant modelling code), which encompasses the plasma as an energy source, heat deposition in plant structures as well as cooling and balance-of-plant in DEMO applications and other reactor relevant analyses. This conference paper presents the first results and validation of the AFSI DD fusion model for different auxiliary heating scenarios (NBI, ICRH) with very different fast particle distribution functions. Both calculated quantities (production rates and spectra) have been compared with experimental data from KN3 and synthetic spectrometer data from ControlRoom code. No unexplained differences have been observed. In future work, AFSI will be extended for synthetic gamma diagnostics and additionally, AFSI will be used as part of the neutron transport calculation chain to model real diagnostics instead of ideal synthetic diagnostics for quantitative benchmarking.

  8. Performance evaluation of beam emanation correction coil for neutron resonance spin echo spectrometer by simulation

    International Nuclear Information System (INIS)

    Maruyama, R.; Tasaki, S.; Hino, M.; Kawabata, Y.

    2004-01-01

    Neutron resonance spin echo (NRSE) method is a spectrometer which uses two RSF (resonance spin flipper) instead of the quietness magnetic field of Mezei type NSE spectrometer, and to measure the change in the speed of the neutron by using the phase difference accumulated in the section between a coupled of RSF in proportion to the resonance frequency of RSF. Having the feature that the magnetic field integration does not depend on the energy resolution by this substitution, and limiting the energy resolution of the NRSE spectrometer become only the beam emanations. The difference of the phase difference by the beam emanation can be corrected by introducing the magnetic field guide with the best magnetic field distribution for the emanation beam. In this research, the beam emanation correction coil for the high-resolution NRSE spectrometer is proposed, and the performance is evaluated by the simulation. As a result, the effectiveness of the correction method proposed by this research was shown. (T.Tanaka)

  9. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1988-01-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs

  10. An in-beam Compton-suppressed Ge spectrometer for nondestructive neutron activation analysis

    International Nuclear Information System (INIS)

    Zaghloul, R.; Abd El-Haleam, A.; Mostafa, M.; Gantner, E.; Ache, H.J.

    1993-04-01

    A high-efficiency compton background suppressed gamma-ray spectrometer by anti-coincidence counting with a NaI(Tl)-shield around a central HPGe-detector for in-beam prompt gamma-ray neutron activation analysis (AC-PGNAA) using a Cf-252 neutron source has been designed and built to provide simultaneous anti-coincidence spectrometry of natural, industrial and environmental samples. The spectrometer consists of a high-purity germanium detector as the main detector and a large volume cylindrical NaI(Tl) detector as a guard detector. The assembly has the ability to measure instantaneously, simultaneously and nondestructively bulk samples up to about 50 cm 3 . Major constituent elements in several rocks and minerals such as H, B, N, Na, Mg, Al, Si, Cl, K, Ca, P, S, Ti, Fe, Sm, Nd, Mn and Gd can be determined, while oxygen cannot be measured due to its small capture cross section (0.27 mb). Several important minor and trace elements such as B, Cd and Hg beside the low residual activity, rare earths and short-lived isotopes could be detected. The sensitivity of the AC-PGNAA technique is limited by the available neutron flux at the target matrix and the neutron absorption cross section of the elements of interest. PGNAA has the advantage to estimate the constituent elements which are difficult to be measured through the delayed gamm-ray measurements such as B, Bi, C, H, P, Tl, Be, Cl and S in industrial and reference materials and those elements which are transformed into other stable isotopes when undergoing neutron capture. The design of the spectrometer assembly, its properties and performance are described

  11. Prototype of the novel CAMEA concept—A backend for neutron spectrometers

    Science.gov (United States)

    Markó, Márton; Groitl, Felix; Birk, Jonas Okkels; Freeman, Paul Gregory; Lefmann, Kim; Christensen, Niels Bech; Niedermayer, Christof; Jurányi, Fanni; Lass, Jakob; Hansen, Allan; Rønnow, Henrik M.

    2018-01-01

    The continuous angle multiple energy analysis concept is a backend for both time-of-flight and analyzer-based neutron spectrometers optimized for neutron spectroscopy with highly efficient mapping in the horizontal scattering plane. The design employs a series of several upward scattering analyzer arcs placed behind each other, which are set to different final energies allowing a wide angular coverage with multiple energies recorded simultaneously. For validation of the concept and the model calculations, a prototype was installed at the Swiss neutron source SINQ, Paul Scherrer Institut. The design of the prototype, alignment and calibration procedures, experimental results of background measurements, and proof-of-concept inelastic measurements on LiHoF4 and h-YMnO3 are presented here.

  12. Development of an ion time-of-flight spectrometer for neutron depth profiling

    Science.gov (United States)

    Cetiner, Mustafa Sacit

    electric field accelerates and then decelerates the emitted secondary electron beam, the magnetic field steers the beam away from the source and focuses it onto the electron microchannel plate detector. The initial momentum distribution of the electron beam is observed to have profound effect on the electron transport time. Hence, the CEM field spectrometer measurements suffer more from spectral broadening at similar operating parameters. The CEM field spectrometer measurements were obtained with a 210Po alpha source at the Penn State Radiation Science and Engineering Center, University Park, PA. Although the PEM field spectrometer suffers less from electron transport time dispersion, the CEM field spectrometer is more suited for application to neutron depth profiling. The multiple small-diameter apertures used in the PEM field configuration considerably reduces the geometric efficiency of the spectrometer. Most of the neutron depth profiling measurements, where isotropic emission of charged particles is observed, have relatively low count rates; hence, high detection efficiency is essential.

  13. Elpasolite Planetary Ice and Composition Spectrometer (EPICS): A Low-Resource Combined Gamma-Ray and Neutron Spectrometer for Planetary Science

    Science.gov (United States)

    Stonehill, L. C.; Coupland, D. D. S.; Dallmann, N. A.; Feldman, W. C.; Mesick, K.; Nowicki, S.; Storms, S.

    2017-12-01

    The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) is an innovative, low-resource gamma-ray and neutron spectrometer for planetary science missions, enabled by new scintillator and photodetector technologies. Neutrons and gamma rays are produced by cosmic ray interactions with planetary bodies and their subsequent interactions with the near-surface materials produce distinctive energy spectra. Measuring these spectra reveals details of the planetary near-surface composition that are not accessible through any other phenomenology. EPICS will be the first planetary science instrument to fully integrate the neutron and gamma-ray spectrometers. This integration is enabled by the elpasolite family of scintillators that offer gamma-ray spectroscopy energy resolutions as good as 3% FWHM at 662 keV, thermal neutron sensitivity, and the ability to distinguish gamma-ray and neutron signals via pulse shape differences. This new detection technology will significantly reduce size, weight, and power (SWaP) while providing similar neutron performance and improved gamma energy resolution compared to previous scintillator instruments, and the ability to monitor the cosmic-ray source term. EPICS will detect scintillation light with silicon photomultipliers rather than traditional photomultiplier tubes, offering dramatic additional SWaP reduction. EPICS is under development with Los Alamos National Laboratory internal research and development funding. Here we report on the EPICS design, provide an update on the current status of the EPICS development, and discuss the expected sensitivity and performance of EPICS in several potential missions to airless bodies.

  14. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN-LNF (Frascati National Laboratories), Via E. Fermi n. 40-00044 Frascati (Italy); Gomez-Ros, J.M. [INFN-LNF (Frascati National Laboratories), Via E. Fermi n. 40-00044 Frascati (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Perez, L. [INFN-LNF (Frascati National Laboratories), Via E. Fermi n. 40-00044 Frascati (Italy); Angelone, M. [ENEA C.R. Frascati, C.P. 65, 00044 Frascati (Italy); Tana, L. [A.O. Universitaria Pisana-Ospedale S. Chiara, Via Bonanno Pisano, Pisa (Italy)

    2012-08-21

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  15. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    International Nuclear Information System (INIS)

    Bedogni, R.; Gómez-Ros, J.M.; Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Pérez, L.; Angelone, M.; Tana, L.

    2012-01-01

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  16. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    Science.gov (United States)

    Bedogni, R.; Gómez-Ros, J. M.; Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Pérez, L.; Angelone, M.; Tana, L.

    2012-08-01

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  17. Measurement of the energy spectrum of cosmic-ray induced neutrons aboard an ER-2 high-altitude airplane

    CERN Document Server

    Goldhagen, P E; Kniss, T; Reginatto, M; Singleterry, R C; Van Steveninck, W; Wilson, J W

    2002-01-01

    Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the atmospheric ionizing radiation (AIR) project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (t...

  18. Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

    Energy Technology Data Exchange (ETDEWEB)

    Chatzidimitriou-Dreismann, C.A., E-mail: dreismann@chem.tu-berlin.de [Institute of Chemistry (Sekr. C2), Technical University of Berlin, D-10623 Berlin (Germany); Gray, E. MacA., E-mail: e.gray@griffith.edu.au [Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane 4111 (Australia); Blach, T.P., E-mail: t.blach@griffith.edu.au [Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane 4111 (Australia)

    2012-06-01

    The 'standard' procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron-proton scattering results that together called into question the validity of the 'standard' calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron-deuteron scattering from D{sub 2} in the backscattering angular range ({theta}>90 Degree-Sign ) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the 'standard' calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present 'standard' calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H{sub 2} molecules. For Case (B), some suggestions as to how the 'standard' calibration could be considerably improved are made.

  19. Mounting and testing of a 'sandwich' type neutron spectrometer with semiconductor detectors and 6Li

    International Nuclear Information System (INIS)

    Fabro, M.A.

    1973-01-01

    Commercial surface barrier detectors (Si(Au)) were used to construct the spectrometer; the 6 LiF was evaporated by vacuum onto a film of Formvar and afterwards over the surface of one of the detectors, with a 6 LiF thickness of 0,2 μm (50 μg/cm 2 ) and 1,5 μm(400 μg/cm 2 ) respectively. Tests were made with slow neutrons and with neutrons from the reactions D(d,n) 3 He (2,65 MeV) and T(d,n) 4 He (14 MeV). The energy resolution for thermal neutrons was about 200 keV (FWHM) for the sum (E sub(t) + E sub(α)) and about 7 keV (FWHM) for the difference (E sub(t) - E sub(α)) with an evaluated efficiency of 5,5x10 -4 , for the sum. For the 2,65 MeV neutrons, the energy resolution was about 240 keV (FWHM) and an evaluated efficiency of 2,1 x 10 -7 . It was not possible to detect 14 MeV neutrons [pt

  20. Comparison of Americium-Beryllium neutron spectrum obtained using activation foil detectors and NE-213 spectrometer

    International Nuclear Information System (INIS)

    Sunny, Sunil; Subbaiah, K.V.; Selvakumaran, T.S.

    1999-01-01

    Neutron spectrum of Americium - Beryllium (α,n) source is measured with two different spectrometers vis-a-vis activation foils (foil detectors) and NE-213 organic scintillator. Activity induced in the foils is measured with 4π-β-γ sodium iodide detector by integrating counts under photo peak and the saturation activity is found by correcting to elapsed time before counting. The data on calculated activity is fed into the unfolding code, SAND-II to obtain neutron spectrum. In the case of organic scintillator, the pulse height spectrum is obtained using MCA and this is processed with unfolding code DUST in order to get neutron spectrum. The Americium - Beryllium (α,n) neutron spectrum thus obtained by two different methods is compared. It is inferred that the NE-213 scintillator spectrum is in excellent agreement with the values beyond 1MeV. Neutron spectrum obtained by activation foils depends on initial guess spectrum and is found to be in reasonable agreement with NE-213 spectrum. (author)

  1. Use of the BD-100R as a neutron spectrometer through applied pressure variation.

    Science.gov (United States)

    White, B; Ebert, D; Munno, F

    1991-05-01

    A study was undertaken to demonstrate the feasibility of using the well-characterized BD-100R neutron bubble dosimeter as a neutron spectrometer in low-level radiation fields. The BD-100R dosimeters used in this work consisted of a test tube containing an elastic polymer with interspersed droplets of two types of Freon: Freon-12 and Freon-114. Each superheated liquid droplet is a potential nucleation site, with the minimum energy needed to form a bubble at the nucleation site being inversely proportional to the square of the difference between the applied and the vapor pressure (i.e., Emin alpha(delta P)-2. For a given dose, the number of bubbles formed continually decreases with increasing applied pressure, until a pressure is reached where no bubbles are formed, since the energy transferred can no longer vaporize the Freon. This investigation is intended to demonstrate the feasibility of measuring an unknown spectrum utilizing the dosimeter response (number of bubbles formed) as a function of the neutron energy (applied pressure). A set of 12 dosimeters was exposed under various applied pressures in a well-characterized neutron energy spectrum at the East Beam Port (EBP) of the Maryland University Training Reactor (MUTR). The dosimeters were placed inside a pressure chamber that could accommodate up to 18 dosimeters. Energy response coefficients (cross-sections) were obtained by spectral unfolding techniques on the known spectrum. The same set of dosimeters were then irradiated using a paraffin-moderated Pu/Be source. Measured spectral estimates obtained using the response coefficients were compared with numerical computations generated using the ANISN computer code. The results indicate that further research using the BD-100R as a neutron spectrometer in low radiation fields is warranted.

  2. Optimized design of the chopper disks and the neutron guide in a disk chopper neutron time-of-flight spectrometer

    International Nuclear Information System (INIS)

    Copley, J.R.D.

    1990-01-01

    We consider important aspects of the performance of a disk chopper neutron time-of-flight spectrometer. The intensity at the sample position, and the contributions of the choppers to the resolution of the instrument, are evaluated as a function of the widths of the slots in the chopper disks and the width of the neutron guide between the disks. We find that there is an optimum choice of the ratios of these widths and that this choice depends on a single parameter which, for elastic scattering, is a simple ratio of distances. When pairs of counter-rotating disks are employed, the widths of the slots can be modified by grossly changing the phase relationship between the members of a chopper pair. If the slot widths are changed, the width of the guide should also be altered in order to maintain the spectrometer in an optimized state. This change in the guide width may be effectively achieved using an arrangement of nested guides. Resolution and intensity calculations demonstrate the important gains which may be realized using this approach. (orig.)

  3. PRISMA - a spectrometer for the measurement of coherent excitations on a pulsed spallation neutron source

    International Nuclear Information System (INIS)

    Andreani, C.; Cilloco, F.; Petrillo, C.; Sacchetti, F.; Windsor, C.G.

    1986-04-01

    The measurement of nuclear and magnetic excitation spectra from single crystal samples remains central to condensed matter physics. The requirements in terms of the range and resolution of the scattering vector Q and energy transfer h/2πω are reviewed and typical experiments with a well defined cross-section are chosen. The performance and limitations of existing instruments are reviewed. A design for a new spectrometer, PRISMA, to be installed on the UK spallation neutron source, ISIS, is presented. Its performance for chosen experiments is given in terms of the Q and h/2πω range covered in a single scan, the resolution and the count rate. (author)

  4. Response matrix calculation of a Bonner Sphere Spectrometer using ENDF/B-VII libraries

    Energy Technology Data Exchange (ETDEWEB)

    Morató, Sergio; Juste, Belén; Miró, Rafael; Verdú, Gumersindo [Instituto de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València (Spain); Guardia, Vicent, E-mail: bejusvi@iqn.upv.es [GD Energy Services, Valencia (Spain). Grupo dominguis

    2017-07-01

    The present work is focused on the reconstruction of a neutron spectra using a multisphere spectrometer also called Bonner Spheres System (BSS). To that, the determination of the response detector curves is necessary therefore we have obtained the response matrix of a neutron detector by Monte Carlo (MC) simulation with MCNP6 where the use of unstructured mesh geometries is introduced as a novelty. The aim of these curves was to study the theoretical response of a widespread neutron spectrometer exposed to neutron radiation. A neutron detector device has been used in this work which is formed by a multispheres spectrometer (BSS) that uses 6 high density polyethylene spheres with different diameters. The BSS consists of a set of 0.95 g/cm{sup 3} high density polyethylene spheres. The detector is composed of a lithium iodide 6LiI cylindrical scintillator crystal 4mm x 4mm size LUDLUM Model 42 coupled to a photomultiplier tube. Thermal tables are required to include polyethylene cross section in the simulation. These data are essential to get correct and accurate results in problems involving neutron thermalization. Nowadays available literature present the response matrix calculated with ENDF.B.V cross section libraries (V.Mares et al 1993) or with ENDF.B.VI (R.Vega Carrillo et al 2007). This work uses two novelties to calculate the response matrix. On the one hand the use of unstructured meshes to simulate the geometry of the detector and the Bonner Spheres and on the other hand the use of the updated ENDF.B.VII cross sections libraries. A set of simulations have been performed to obtain the detector response matrix. 29 mono energetic neutron beams between 10 KeV to 20 MeV were used as source for each moderator sphere up to a total of 174 simulations. Each mono energetic source was defined with the same diameter as the moderating sphere used in its corresponding simulation and the spheres were uniformly irradiated from the top of the photomultiplier tube. Some

  5. Total cross section measurement of radioactive isotopes with a thin beam neutron spectrometer

    International Nuclear Information System (INIS)

    Razbudej, V.F.; Vertebnyj, V.P.; Padun, G.S.; Muravitskij, A.V.

    1975-01-01

    The method for measuring the neutron total cross sections of radioactive isotopes by a time-of-flight spectrometer with a narrow (0.17 mm in diameter) beam of thermal neutrons is described. The distinguishing feature of this method is the use of capillary samples with a small amount of substance (0.05-1.0 mg). The energy range is 0.01-0.3 eV. The total cross sections of irradiated samples of sub(153)Eu and sub(151)Eu are measured. From them are obtained the cross sections of sub(152)Eu (Tsub(1/2)=12.4 g) and of sub(154)E (Tsub(1/2)=8.6 yr); they equal 11400+-1400 and 1530+-190 barn at E=0.0253 eV. The cross section of the sub(152)Eu absorption for the thermal spectrum (T=333 K) is determined by the activation method; it is 8900+-1200 barn

  6. Thermal neutron detector and gamma-ray spectrometer utilizing a single material

    Science.gov (United States)

    Stowe, Ashley; Burger, Arnold; Lukosi, Eric

    2017-05-02

    A combined thermal neutron detector and gamma-ray spectrometer system, including: a detection medium including a lithium chalcopyrite crystal operable for detecting thermal neutrons in a semiconductor mode and gamma-rays in a scintillator mode; and a photodetector coupled to the detection medium also operable for detecting the gamma rays. Optionally, the detection medium includes a .sup.6LiInSe.sub.2 crystal. Optionally, the detection medium comprises a compound formed by the process of: melting a Group III element; adding a Group I element to the melted Group III element at a rate that allows the Group I and Group III elements to react thereby providing a single phase I-III compound; and adding a Group VI element to the single phase I-III compound and heating; wherein the Group I element includes lithium.

  7. γ-Ray background sources in the VESUVIO spectrometer at ISIS spallation neutron source

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Perelli Cippo, E.; Gorini, G.; Tardocchi, M.; Schooneveld, E.M.; Andreani, C.; Senesi, R.

    2009-01-01

    An investigation of the gamma background was carried out in the VESUVIO spectrometer at the ISIS spallation neutron source. This study, performed with a yttrium-aluminum-perovskite (YAP) scintillator, follows high resolution pulse height measurements of the gamma background carried out on the same instrument with the use of a high-purity germanium detector. In this experimental work, a mapping of the gamma background was attempted, trying to find the spatial distribution and degree of directionality of the different contributions identified in the previous study. It is found that the gamma background at low times is highly directional and mostly due to the gamma rays generated in the moderator-decoupler system. The other contributions, consistently to the findings of a previous experiment, are identified as a nearly isotropic one due to neutron absorption in the walls of the experimental hall, and a directional one coming from the beam dump.

  8. {gamma}-Ray background sources in the VESUVIO spectrometer at ISIS spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Pietropaolo, A. [CNISM Milano-Bicocca, Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); NAST Center (Nanoscienze-Nanotecnologie-Strumentazione), Universita degli Studi di Roma Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy)], E-mail: antonino.pietropaolo@mib.infn.it; Perelli Cippo, E. [Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); Gorini, G. [CNISM Milano-Bicocca, Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); NAST Center (Nanoscienze-Nanotecnologie-Strumentazione), Universita degli Studi di Roma Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy); Tardocchi, M. [Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); Schooneveld, E.M. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire 0QX OX11 (United Kingdom); Andreani, C.; Senesi, R. [Universia degli Studi di Roma Tor Vergata, Dipartimento di Fisica and NAST Center (Nanoscienze-Nanotecnologie-Strumentazione), via della Ricerca Scientifica 1, 00133 Roma (Italy)

    2009-09-01

    An investigation of the gamma background was carried out in the VESUVIO spectrometer at the ISIS spallation neutron source. This study, performed with a yttrium-aluminum-perovskite (YAP) scintillator, follows high resolution pulse height measurements of the gamma background carried out on the same instrument with the use of a high-purity germanium detector. In this experimental work, a mapping of the gamma background was attempted, trying to find the spatial distribution and degree of directionality of the different contributions identified in the previous study. It is found that the gamma background at low times is highly directional and mostly due to the gamma rays generated in the moderator-decoupler system. The other contributions, consistently to the findings of a previous experiment, are identified as a nearly isotropic one due to neutron absorption in the walls of the experimental hall, and a directional one coming from the beam dump.

  9. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Johnson, M Gatu; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Magoon, J; Meyerhofer, D D; Sangster, T C; Shoup, M; Ulreich, J; Ashabranner, R C; Bionta, R M; Carpenter, A C; Felker, B; Khater, H Y; LePape, S; MacKinnon, A; McKernan, M A; Moran, M; Rygg, J R; Yeoman, M F; Zacharias, R; Leeper, R J; Fletcher, K; Farrell, M; Jasion, D; Kilkenny, J; Paguio, R

    2013-04-01

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  10. The Magnetic Recoil Spectrometer for time-resolved neutron measurements (MRSt) at the NIF

    Science.gov (United States)

    Parker, C. E.; Frenje, J. A.; Wink, C. W.; Gatu Johnson, M.; Lahmann, B.; Li, C. K.; Seguin, F. H.; Petrasso, R. D.; Hilsabeck, T. J.; Kilkenny, J. D.; Bionta, R.; Casey, D. T.; Khater, H. Y.; Forrest, C. J.; Glebov, V. Yu.; Sorce, C.; Hares, J. D.; Siegmund, O. H. W.

    2017-10-01

    The next-generation Magnetic Recoil Spectrometer, called MRSt, will provide time-resolved measurements of the DT-neutron spectrum. These measurements will provide critical information about the time evolution of the fuel assembly, hot-spot formation, and nuclear burn in Inertial Confinement Fusion (ICF) implosions at the National Ignition Facility (NIF). The neutron spectrum in the energy range 12-16 MeV will be measured with high accuracy ( 5%), unprecedented energy resolution ( 100 keV) and, for the first time ever, time resolution ( 20 ps). An overview of the physics motivation, conceptual design for meeting these performance requirements, and the status of the offline tests for critical components will be presented. This work was supported in part by the U.S. DOE, LLNL, and LLE.

  11. Study of the environmental neutron spectrum at Zacatecas city

    International Nuclear Information System (INIS)

    Vega C, H.R.

    2003-01-01

    The environmental neutron spectrum has been measured at Zacatecas City in Mexico. Neutron spectrum was unfolded from count rates obtained with a multisphere neutron spectrometer with a Li I(Eu) scintillator. With the spectrum information the ambient dose equivalent and the isotropic effective dose were calculated. A model based upon the geomagnetic latitude and the altitude above sea level, that allows to estimate the neutron fluence rate is proposed, the model results are compared with total neutron fluences measured at several locations worldwide. Environmental neutron spectrum shows peaks at 1 and 100 MeV as well as a relevant amount of low energy neutrons. The neutron fluence rate was 65 ± 3 cm -2 -h -1 , producing 13.7 ± 0.6 n Sv-h -1 due to ambient dose equivalent rate and an isotropic effective dose rate of 14.1 ± 0.6 n Sv-h -1 . Neutron fluence rates predicted with the model are in agreement with those reported in the literature. (Author)

  12. The performance of neutron scattering spectrometers at a long-pulse spallation source

    International Nuclear Information System (INIS)

    Pynn, R.

    1997-01-01

    In this document the author considers the performance of a long pulse spallation source for those neutron scattering experiments that are usually performed with a monochromatic beam at a continuous wave (CW) source such as a nuclear reactor. The first conclusion drawn is that comparison of the performance of neutron scattering spectrometers at CW and pulsed sources is simpler for long-pulsed sources than it is for the short-pulse variety. Even though detailed instrument design and assessment will require Monte Carlo simulations (which have already been performed at Los Alamos for SANS and reflectometry), simple arguments are sufficient to assess the approximate performance of spectrometers at an LPSS and to support the contention that a 1 MW long-pulse source can provide attractive performance, especially for instrumentation designed for soft-condensed-matter science. Because coupled moderators can be exploited at such a source, its time average cold flux is equivalent to that of a research reactor with a power of about 15 MW, so only a factor of 4 gain from source pulsing is necessary to obtain performance that is comparable with the ILL. In favorable cases, the gain from pulsing can be even more than this, approaching the limit set by the peak flux, giving about 4 times the performance of the ILL. Because of its low duty factor, an LPSS provides the greatest performance gains for relatively low resolution experiments with cold neutrons. It should thus be considered complementary to short pulse sources which are most effective for high resolution experiments using thermal or epithermal neutrons

  13. spectrometer

    Directory of Open Access Journals (Sweden)

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  14. First magnon of BATAN's neutron triple-axis spectrometer

    International Nuclear Information System (INIS)

    I Sumirat

    2016-01-01

    The National Nuclear Energy Agency of Indonesia (BATAN) has one dedicated spectrometer for inelastic neutron scattering experiments. The instrument is a thermal neutron triple-axis spectrometer known as SN1. SN1 was installed in 1992 in the experimental hall of G. A. Siwabessy Research Reactor, Serpong, Banten. Malfunctions of the hardware and software have prevented the instrument from performing inelastic scattering measurements since 1996. The 2011-2015 five years project has been initiated to revitalize and optimize the SN1. The project serves as a preparation for the utilization of SN1 for the investigation of lattice dynamics, spin wave and magnetic excitations in condensed matters that will be started in 2016. In 2013, SN1 has successfully been repaired and was able to measure phonon dispersion relation of available single crystals, i.e., Cu, pyrolytic graphite (PG), Ge, and Al. In 2015, the first experiment on magnetic excitation to investigate magnon dispersion relation of a known Fe single crystal has been carried out. Standard methods of inelastic scattering measurements, i.e., a constant-energy transfer hω with either fixed final neutron energy E f = 14.7 MeV or fixed incoming neutron energy E i = 30.59 MeV, and a constant momentum transfer Q with fixed incoming neutron energy E i = 30.59 MeV, were applied to measure the low-energy magnetic excitations. For fixed E f measurement, a 5-cm thick PG filter was set between the sample and the analyzer to eliminate λ/n harmonics. To limit the energy and momentum spreads of the beam, collimations of 40 minutes were applied before and after the sample. The spin waves were measured along the three principal symmetry directions of [00ζ], [ζζ0], and [ζζζ] . The measured magnons were compared to values in reference and were found to be in a good agreement with them. With such accomplishments, we are convinced that SN1 is now ready for its inelastic scattering application and will become one of BATAN

  15. Large solid-angle spectrometers for studies of double-differential charged-particle and neutron emission cross sections

    International Nuclear Information System (INIS)

    Baba, M.; Matsuyama, S.; Sanami, T.; Soda, D.; Matsuyama, I.; Ohkubo, T.; Iwasaki, S.; Hirakawa, N.

    1995-01-01

    The large solid-angle spectrometer developed for studies of double-differential cross sections of (n, charged particle) and (n, xn') reactions using a gas-filled gridded-ionization chamber and an 80-cm long liquid scintillator is described. The charged particle spectrometer is a twin gas-filled gridded-ionization chamber with solid angle close to 4 π designed to achieve high stopping power and background suppression. The neutron spectrometer is a long NE213 liquid scintillation detector having position sensitivity. It is used as a large single spectrometer or a position sensitive detector covering wide scattering angle. The facility design, performance and examples of application are discussed. The conclusion is made that the facility provides a useful mean for studies in particular for reactions with small cross sections and/or for neutron sources with low intensity. 15 refs., 15 figs

  16. BRISP, a new small-angle time-of-flight neutron spectrometer to study collective dynamics in disordered matter

    Directory of Open Access Journals (Sweden)

    A.Orecchini

    2008-03-01

    Full Text Available An outline is given of the new neutron Brillouin Spectrometer BRISP which was installed during the last years and recently became fully operational at the Institute Laue-Langevin in Grenoble (France. The main technical features are described and some of the first experimental results are presented, demonstrating the present capabilities of this new-type inelastic small-angle spectrometer. Future upgrades are foreseen and expected to further improve the instrument performances.

  17. Site-specific calibration of the Hanford personnel neutron dosimeter

    International Nuclear Information System (INIS)

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.; Rathbone, B.A.

    1994-10-01

    A new personnel dosimetry system, employing a standard Hanford thermoluminescent dosimeter (TLD) and a combination dosimeter with both CR-39 nuclear track and TLD-albedo elements, is being implemented at Hanford. Measurements were made in workplace environments in order to verify the accuracy of the system and establish site-specific factors to account for the differences in dosimeter response between the workplace and calibration laboratory. Neutron measurements were performed using sources at Hanford's Plutonium Finishing Plant under high-scatter conditions to calibrate the new neutron dosimeter design to site-specific neutron spectra. The dosimeter was also calibrated using bare and moderated 252 Cf sources under low-scatter conditions available in the Hanford Calibration Laboratory. Dose equivalent rates in the workplace were calculated from spectrometer measurements using tissue equivalent proportional counter (TEPC) and multisphere spectrometers. The accuracy of the spectrometers was verified by measurements on neutron sources with calibrations directly traceable to the National Institute of Standards and Technology (NIST)

  18. MACS—a new high intensity cold neutron spectrometer at NIST

    International Nuclear Information System (INIS)

    Rodriguez, J A; Adler, D M; Brand, P C; Cook, J C; Brocker, C; Huang, Z; Hundertmark, P; Lynn, J W; Maliszewskyj, N C; Moyer, J; Pierce, D; Pike, T D; Vilaseca, R; Broholm, C; Hammond, R; Orndorff, J; Scharfstein, G; Smee, S A

    2008-01-01

    We describe a novel cold neutron spectrometer under development at NIST optimized for wave vector resolved spectroscopy with incident energies between 2.1 meV and 20 meV and energy resolution from 0.05 meV (E i = 2.1 meV) to 3.0 meV (E i = 20 meV). By using a 1428 cm 2 double focusing PG (0 0 2) monochromator close to the National Institute of Standards and Technology (NIST) cold neutron source the instrument provides up to 5 × 10 8 neutrons cm −2 s −1 on a 8 cm 2 sample area. The measured performance is consistent with Monte Carlo simulations. The monochromating system, which includes radial collimators, three filters and a variable beam aperture, offers considerable flexibility in optimizing Q-resolution, energy resolution and intensity. The detector system will consist of an array of 20 channels which combined will subtend a solid angle of 0.2 sr. This is approximately a factor of 40 more than a conventional triple axis spectrometer. Each detector channel contains a vertically focusing double crystal analyzer system (DXAL) actuated by a single stepping motor. We find identical integrated reflectivity at approximately 10% coarser energy resolution for the 130' mosaic double bounce analyzer as compared to a conventional 25' analyzer at the same energy. The vertical focusing of the DXAL allows for smaller detectors for enhanced signal to noise with 8° vertical acceptance. Options for post sample collimators and filters provide flexibility in the choice of scattered beam energy and wavevector resolution

  19. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R

    2012-10-01

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  20. Design and Construction of the Control System for Batan Small Angle Neutron Scattering Spectrometer (SMARter

    Directory of Open Access Journals (Sweden)

    E. Santoso

    2008-07-01

    Full Text Available A 36 m Small Angle Neutron Scattering (SANS Spectrometer (SMARTer has been installed in Serpong, Indonesia in 1992. As time goes by, the original main computer was out of order and the instrument had not been operated since 2003. In order to activate the SMARTer, in the year 2005, a work on designing and constructing a new control system for SMARTer was carried out. The main component of this control system is a programmable peripheral I/O (IC PPI 8255 and was assembled as a plug-in board at an ISA slot of a personal computer. An IC PPI 8255 was programmed to control the mechanical movements of the instrument’s components: four neutron guide tubes, six pinholes collimator, a detector and a beam stopper. The test either with or without neutron beam has shown that this control system can be implemented for the mechanical movements of SMARTer. Error of moving the detector in the distance range of 1.5 m – 18 m is only 1 mm and the other movements have no error at all (precise.

  1. Concepts and Engineering Aspects of a Neutron Resonance Spin-Echo Spectrometer for the National Institute of Standards and Technology Center for Neutron Research

    Science.gov (United States)

    Cook, Jeremy C.

    2014-01-01

    Following a brief introduction, the Neutron Resonance Spin-Echo (NRSE) principle is discussed classically in Sec. 2. In Sec. 3, two idealized 4-coil NRSE spectrometers are discussed (one using single π-flipper coil units and one using paired “bootstrap” coils); some idealized (exact π-flip) expressions are given for the spin-echo signal and some theoretical limitations are discussed. A more quantum mechanical discussion of NRSE is presented in Sec. 4 and additional theory related to the spin-echo signal, including wavelength-dependence, is given is Sec. 5. Factors affecting the instrumental resolution are discussed in Sec. 6. In Sec. 7, a variety of engineering issues are assessed in the context of challenging performance goals for a NIST Center for Neutron Research (NCNR) NRSE spectrometer. In Sec. 8, some Monte Carlo simulations are presented that examine the combined influences of spectrometer imperfections on the NRSE signal. These are compared with analytical predictions developed in previous sections. In Sec. 9, possible alternatives for a NCNR NRSE spectrometer configuration are discussed together with a preliminary assessment of the spectrometer neutron guide requirements. A summary of some of the useful formulas is given in Appendix A. PMID:26601027

  2. High-sensitive spectrometer of fast neutrons and the results of fast neutron background flux measurements at the Gallium-Germanium Solar Neutrino Experiment

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S

    2002-01-01

    The principle of operation, design, registration system and main characteristics of a fast neutron spectrometer are described. The spectrometer is intended for direct measurements of ultra low fluxes of fast neutrons. It is sensitive to neutron fluxes of 10 sup - sup 7 cm sup - sup 2 s sup - sup 1 and lower. The detection efficiency of fast neutrons with simultaneous energy measurement was determined from Monte-Carlo simulation to be equal to 0.11+-0.01. The background counting rate in the detector corresponds to a neutron flux of (6.5+-2.1)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The natural neutron flux from the surrounding mine rock at the depth of 4600 m of water equivalent was measured to be (7.3+-2.4)x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in the range 1.0-11.0 MeV. The flux of fast neutrons in the SAGE main room was measured to be <2.3x10 sup - sup 7 cm sup - sup 2 s sup - sup 1 in 1.0-11.0 MeV energy range.

  3. A PCI time digitizer for the new JET time-of-flight neutron spectrometer

    International Nuclear Information System (INIS)

    Sousa, J.; Batista, A.J.N.; Combo, A.; Pereira, R.; Cruz, N.; Carvalho, P.; Varandas, C.A.F.; Conroy, S.; Ericsson, G.; Kaellne, J.

    2004-01-01

    A PCI time digitizer module with eight independent time-to-digital converter (TDC) channels is being developed for the new time-of-flight spectrometer designed for optimized rate (TOFOR) which diagnoses deuterium plasmas of the EFDA-JET tokamak. The module shall measure with high accuracy the flight-times of 2.5 MeV neutrons in the 100 ns range as given by two groups of scintillation detectors operating at average event rates from the expected 500 kHz up to 5 MHz. The module stores up to 64 million hit-times with a resolution of 0.4 ns and incorporates a digital signal processor and a system-on-chip device which performs the data transfer, the device control/monitoring and may perform statistical, data reduction or control algorithms in real-time

  4. Neutron-damaged GaAs detectors for use in a Compton spectrometer

    International Nuclear Information System (INIS)

    Kammeraad, J.E.; Sale, K.E.; Wang, C.L.; Baltrusaitis, R.M.

    1992-01-01

    Detectors made of GaAs are being studies for use on the focal plane of a Compton spectrometer which measures 1-MeV to 25-MeV gamma rays with high energy resolution (1% or 100 keV, whichever is greater) and 200-ps time resolution. The detectors are GaAs chips that have been neutron-damaged to improve the time response. The detectors will be used to measure fast transient signals in the current mode. The properties of various GaAs detector configurations are being studied by bombarding sample detectors with short pulses of 4-MeV to 16-MeV electrons at the Linac Facility at EG ampersand G Energy Measurements, Inc., Santa Barbara Operations. Measurements of detector sensitivity and impulse response versus detector bias, thickness, and electron beam energy and intensity have been performed and are presented. 5 refs

  5. The new high field photoexcitation muon spectrometer at the ISIS pulsed neutron and muon source.

    Science.gov (United States)

    Yokoyama, K; Lord, J S; Murahari, P; Wang, K; Dunstan, D J; Waller, S P; McPhail, D J; Hillier, A D; Henson, J; Harper, M R; Heathcote, P; Drew, A J

    2016-12-01

    A high power pulsed laser system has been installed on the high magnetic field muon spectrometer (HiFi) at the International Science Information Service pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high magnetic field, which opens new applications of muon spin spectroscopy. In this report we give an overview of the principle of the HiFi laser system and describe the newly developed techniques and devices that enable precisely controlled photoexcitation of samples in the muon instrument. A demonstration experiment illustrates the potential of this unique combination of the photoexcited system and avoided level crossing technique.

  6. Independent measuring station for the GNEJS neutron spectrometer information and measurement system

    International Nuclear Information System (INIS)

    Gorokhov, I.S.; Laptev, A.B.; Marchenkov, V.V.; Tubol'tsev, Yu.V.; Fokin, E.Yu.; Shcherbakov, O.A.

    1984-01-01

    An independent measuring station (IMS) being a part of the information and measuring system of the neutron time-of-flight spectrometer is described. IMS represents the time (time-to-amplitude or time-to-angular) module analyzer assembled on the base of one or several CAMAC crates. The station permits to perform time measurements as well as the time measurements with amplitude weighing in an independent mode with subseqUent data transmission the central PDP-11/05 computer. The station processor unit is an independent controller. The software consists of the programming langUage of the controller from local terminal and programs ensuring measuring and shaping the spectra with their output on TV display devic. communication with the computer and dialogue with the operator

  7. A real-time neutron-gamma discriminator based on the support vector machine method for the time-of-flight neutron spectrometer

    Science.gov (United States)

    Wei, ZHANG; Tongyu, WU; Bowen, ZHENG; Shiping, LI; Yipo, ZHANG; Zejie, YIN

    2018-04-01

    A new neutron-gamma discriminator based on the support vector machine (SVM) method is proposed to improve the performance of the time-of-flight neutron spectrometer. The neutron detector is an EJ-299-33 plastic scintillator with pulse-shape discrimination (PSD) property. The SVM algorithm is implemented in field programmable gate array (FPGA) to carry out the real-time sifting of neutrons in neutron-gamma mixed radiation fields. This study compares the ability of the pulse gradient analysis method and the SVM method. The results show that this SVM discriminator can provide a better discrimination accuracy of 99.1%. The accuracy and performance of the SVM discriminator based on FPGA have been evaluated in the experiments. It can get a figure of merit of 1.30.

  8. The time-of-flight small-angle scattering spectrometer SAN at the KENS pulsed cold neutron source

    International Nuclear Information System (INIS)

    Ishikawa, Y.; Furusaka, M.; Hasegawa, K.

    1986-01-01

    This paper describes the configuration and performance of a new time-of-flight (TOF) small-angle neutron scattering spectrometer SAN installed at the pulsed cold neutron source (KENS) at the National Laboratory for High Energy Physics (KEK). The spectrometer has advantages over conventional small-angle scattering apparatus: one is its capability for simultaneous measurements over a wide Q range (0.003≤Q≤4 A -1 ) and another is the new information that it provides by exploiting the wavelength dependence of the scattering. For example, the inelastic and elastic scattering can be separated without performing an energy analysis. The design principles of this type of spectrometer are also discussed. (orig.)

  9. Simulation for developing new pulse neutron spectrometers I. Creation of new McStas components of moderators of JSNS

    CERN Document Server

    Tamura, I; Arai, M; Harada, M; Maekawa, F; Shibata, K; Soyama, K

    2003-01-01

    Moderators components of the McStas code have been created for the design of JSNS instruments. Three cryogenic moderators are adopted in JSNS, one is coupled H sub 2 moderators for high intensity experiments and other two are decoupled H sub 2 with poisoned or unpoisoned for high resolution moderators. Since the characteristics of neutron beams generated from moderators make influence on the performance of pulse neutron spectrometers, it is important to perform the Monte Carlo simulation with neutron source component written precisely. The neutron spectrum and time structure were calculated using NMTC/JAERI97 and MCNP4a codes. The simulation parameters, which describe the pulse shape over entire spectrum as a function of time, are optimized. In this paper, the creation of neutron source components for port No.16 viewed to coupled H sub 2 moderator and for port No.11 viewed to decoupled H sub 2 moderator of JSNS are reported.

  10. The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF).

    Science.gov (United States)

    Frenje, J A; Hilsabeck, T J; Wink, C W; Bell, P; Bionta, R; Cerjan, C; Gatu Johnson, M; Kilkenny, J D; Li, C K; Séguin, F H; Petrasso, R D

    2016-11-01

    The next-generation magnetic recoil spectrometer for time-resolved measurements of the neutron spectrum has been conceptually designed for the National Ignition Facility. This spectrometer, called MRSt, represents a paradigm shift in our thinking about neutron spectrometry for inertial confinement fusion applications, as it will provide simultaneously information about the burn history and time evolution of areal density (ρR), apparent ion temperature (T i ), yield (Y n ), and macroscopic flows during burn. From this type of data, an assessment of the evolution of the fuel assembly, hotspot, and alpha heating can be made. According to simulations, the MRSt will provide accurate data with a time resolution of ∼20 ps and energy resolution of ∼100 keV for total neutron yields above ∼10 16 . At lower yields, the diagnostic will be operated at a higher-efficiency, lower-energy-resolution mode to provide a time resolution of ∼20 ps.

  11. Constant-q data representation in Neutron Compton scattering on the VESUVIO spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Senesi, R. [Dipartimento di Fisica, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy)], E-mail: roberto.senesi@roma2.infn.it; Pietropaolo, A.; Andreani, C. [Dipartimento di Fisica, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy)

    2008-09-01

    Standard data analysis on the VESUVIO spectrometer at ISIS is carried out within the Impulse Approximation framework, making use of the West scaling variable y. The experiments are performed using the time-of-flight technique with the detectors positioned at constant scattering angles. Line shape analysis is routinely performed in the y-scaling framework, using two different (and equivalent) approaches: (1) fitting the parameters of the recoil peaks directly to fixed-angle time-of-flight spectra; (2) transforming the time-of-flight spectra into fixed-angle y spectra, referred to as the Neutron Compton Profiles, and then fitting the line shape parameters. The present work shows that scattering signals from different fixed-angle detectors can be collected and rebinned to obtain Neutron Compton Profiles at constant wave vector transfer, q, allowing for a suitable interpretation of data in terms of the dynamical structure factor, S(q,{omega}). The current limits of applicability of such a procedure are discussed in terms of the available q-range and relative uncertainties for the VESUVIO experimental set up and of the main approximations involved.

  12. Constant-q data representation in Neutron Compton scattering on the VESUVIO spectrometer

    International Nuclear Information System (INIS)

    Senesi, R.; Pietropaolo, A.; Andreani, C.

    2008-01-01

    Standard data analysis on the VESUVIO spectrometer at ISIS is carried out within the Impulse Approximation framework, making use of the West scaling variable y. The experiments are performed using the time-of-flight technique with the detectors positioned at constant scattering angles. Line shape analysis is routinely performed in the y-scaling framework, using two different (and equivalent) approaches: (1) fitting the parameters of the recoil peaks directly to fixed-angle time-of-flight spectra; (2) transforming the time-of-flight spectra into fixed-angle y spectra, referred to as the Neutron Compton Profiles, and then fitting the line shape parameters. The present work shows that scattering signals from different fixed-angle detectors can be collected and rebinned to obtain Neutron Compton Profiles at constant wave vector transfer, q, allowing for a suitable interpretation of data in terms of the dynamical structure factor, S(q,ω). The current limits of applicability of such a procedure are discussed in terms of the available q-range and relative uncertainties for the VESUVIO experimental set up and of the main approximations involved

  13. Equatorial locations of water on Mars: Improved resolution maps based on Mars Odyssey Neutron Spectrometer data

    Science.gov (United States)

    Wilson, Jack T.; Eke, Vincent R.; Massey, Richard J.; Elphic, Richard C.; Feldman, William C.; Maurice, Sylvestre; Teodoro, Luís F. A.

    2018-01-01

    We present a map of the near subsurface hydrogen distribution on Mars, based on epithermal neutron data from the Mars Odyssey Neutron Spectrometer. The map's spatial resolution is approximately improved two-fold via a new form of the pixon image reconstruction technique. We discover hydrogen-rich mineralogy far from the poles, including ∼10 wt.% water equivalent hydrogen (WEH) on the flanks of the Tharsis Montes and >40 wt.% WEH at the Medusae Fossae Formation (MFF). The high WEH abundance at the MFF implies the presence of bulk water ice. This supports the hypothesis of recent periods of high orbital obliquity during which water ice was stable on the surface. We find the young undivided channel system material in southern Elysium Planitia to be distinct from its surroundings and exceptionally dry; there is no evidence of hydration at the location in Elysium Planitia suggested to contain a buried water ice sea. Finally, we find that the sites of recurring slope lineae (RSL) do not correlate with subsurface hydration. This implies that RSL are not fed by large, near-subsurface aquifers, but are instead the result of either small ( dry, granular flows.

  14. Measurement of {sup 241}Am-Be spectra (bare and Pb-covered) using TLD pairs in multi-spheres: Spectrum unfolding by different methods

    Energy Technology Data Exchange (ETDEWEB)

    Tripathy, S.P. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India)], E-mail: Sam.tripathy@gmail.com; Bakshi, A.K. [Radiological Physics and Advisory Division, BARC, Mumbai 400085 (India); Sathian, V.; Tripathi, S.M. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India); Vega-carrillo, H.R. [Unidad Academica de Estudios Nucleares de la, Universidad Autonoma de Zacatecas, Apdo. Postal 336, 98000 Zacatecas, Zac. (Mexico); Nandy, M. [Saha Institute of Nuclear Physics, 1/AF Bidhan Nagar, Kolkata 700064 (India); Sarkar, P.K. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India); Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700064 (India); Sharma, D.N. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India)

    2009-01-11

    The neutron spectra from a Pb-covered and a bare (without Pb-cover) {sup 241}Am-Be ({alpha},n) source were measured using thermoluminescent detector (TLD) pairs of {sup 6}LiF and {sup 7}LiF with high-density polyethylene (HDPE) multi-spheres of seven different diameters. A total of 8 distinct neutron response signals (including a bare mode exposure) were obtained from which the energy distribution for the entire energy range was generated with the help of different neutron spectrum unfolding methods, viz. BUNKI, BUNKIUT and Frascati unfolding interactive tool (FRUIT). Shape of these spectra are matching very well and is also comparable with the standard IAEA {sup 241}Am-Be spectrum, thus, validating the unfolding methods used in this work. The effect of Pb-cover on the spectrum and the unfolding details are reported in the paper.

  15. Measurement of 241Am-Be spectra (bare and Pb-covered) using TLD pairs in multi-spheres: Spectrum unfolding by different methods

    Science.gov (United States)

    Tripathy, S. P.; Bakshi, A. K.; Sathian, V.; Tripathi, S. M.; Vega-carrillo, H. R.; Nandy, M.; Sarkar, P. K.; Sharma, D. N.

    2009-01-01

    The neutron spectra from a Pb-covered and a bare (without Pb-cover) 241Am-Be (α,n) source were measured using thermoluminescent detector (TLD) pairs of 6LiF and 7LiF with high-density polyethylene (HDPE) multi-spheres of seven different diameters. A total of 8 distinct neutron response signals (including a bare mode exposure) were obtained from which the energy distribution for the entire energy range was generated with the help of different neutron spectrum unfolding methods, viz. BUNKI, BUNKIUT and Frascati unfolding interactive tool (FRUIT). Shape of these spectra are matching very well and is also comparable with the standard IAEA 241Am-Be spectrum, thus, validating the unfolding methods used in this work. The effect of Pb-cover on the spectrum and the unfolding details are reported in the paper.

  16. A proton-recoil neutron spectrometer for time-dependent ion temperatures on the National Ignition Facility

    International Nuclear Information System (INIS)

    Murphy, T.J.

    1995-01-01

    Ion temperatures from inertial confinement fusion targets are usually determined by measuring the Doppler broadening of the neutron spectrum using the time-of-flight method. Measurement systems are generally designed so that the contribution of the duration of neutron production (∼100 ps) to the width of the neutron signal is negligible. This precludes the possibility of time-dependent ion temperature. If, however, one could measure the neutron energy and arrival time at a detector independently, then time-dependent neutron spectra could be obtained, and ion temperature information deduced. A concept utilizing a proton-recoil neutron spectrometer has been developed in which recoil protons from a small plastic foil are measured. From the energy, arrival time, and recoil angle of the recoil proton, the birth time and energy of the incident neutron can be deduced. The sensitivity of the system is low, but the higher anticipated neutron yields from the proposed National Ignition Facility may make the technique feasible. Large scintillator arrays currently in use on the Nova facility for neutron spectral measurements consist of ∼1,000 channels and detect between 50 and 500 counts for typical time-integrated data. Time-dependent results would then require about an order of magnitude larger system. Key issues for making this system feasible will be keeping the cost per channel low while allowing adequately time (∼ 50 ps), energy (20 keV), and angular resolution (2 mrad) for each of the proton detectors

  17. Neutron Spectrometer Prospecting in the Mojave Volatiles Project Analog Field Test

    Science.gov (United States)

    Elphic, R. C.; Heldmann, J. L.; Colaprete, A.; Hunt, D. R.; Deans, M. C.; Lim, D. S.; Foil, G.; Fong, T.

    2015-01-01

    We know that volatiles are sequestered at the poles of the Moon. While we have evidence of water ice and a number of other compounds based on remote sensing, the detailed distribution, and physical and chemical form are largely unknown. Additional orbital studies of lunar polar volatiles may yield further insights, but the most important next step is to use landed assets to fully characterize the volatile composition and distribution at scales of tens to hundreds of meters. To achieve this range of scales, mobility is needed. Because of the proximity of the Moon, near real-time operation of the surface assets is possible, with an associated reduction in risk and cost. This concept of operations is very different from that of rovers on Mars, and new operational approaches are required to carry out such real-time robotic exploration. The Mojave Volatiles Project (MVP) was a Moon-Mars Analog Mission Activities (MMAMA) program project aimed at (1) determining effective approaches to operating a real-time but short-duration lunar surface robotic mission, and (2) performing prospecting science in a natural setting, as a test of these approaches. Here we describe some results from the first such test, carried out in the Mojave Desert between 16 and 24 October, 2014. The test site was an alluvial fan just E of the Soda Mountains, SW of Baker, California. This site contains desert pavements, ranging from the late Pleistocene to early-Holocene in age. These pavements are undergoing dissection by the ongoing development of washes. A principal objective was to determine the hydration state of different types of desert pavement and bare ground features. The mobility element of the test was provided by the KREX-2 rover, designed and operated by the Intelligent Robotics Group at NASA Ames Research Center. The rover-borne neutron spectrometer measured the neutron albedo at both thermal and epithermal energies. Assuming uniform geochemistry and material bulk density, hydrogen as

  18. Altitude variation of cosmic-ray neutrons

    International Nuclear Information System (INIS)

    Nakamura, T.; Uwamino, Y.; Ohkubo, T.; Hara, A.

    1987-01-01

    The altitude variation of the cosmic-ray neutron energy spectrum and the dose equivalent rate was measured at an average geomagnetic latitude of 24 degrees N by using the high-efficiency multi-sphere neutron spectrometer and neutron dose-equivalent counter developed by the authors. The data were obtained from a 2-h flight over Japan on 27 February 1985. The neutron energy spectra measured at sea level and at altitudes of 4880 m and at 11,280 m were compared with the calculated spectra of O'Brien and with other experimental spectra, and they are in moderately good agreement with them. The dose equivalent rate increases according to a quadratic curve up to about 6000 m and then increases linearly between 6000 m and 11,280 m. The dependence of dose equivalent rates at sea level and at an altitude of 12,500 m on geomagnetic latitude also is given by referring to other experimental results

  19. Design and commissioning of a high magnetic field muon spin relaxation spectrometer at the ISIS pulsed neutron and muon source.

    Science.gov (United States)

    Lord, J S; McKenzie, I; Baker, P J; Blundell, S J; Cottrell, S P; Giblin, S R; Good, J; Hillier, A D; Holsman, B H; King, P J C; Lancaster, T; Mitchell, R; Nightingale, J B; Owczarkowski, M; Poli, S; Pratt, F L; Rhodes, N J; Scheuermann, R; Salman, Z

    2011-07-01

    The high magnetic field (HiFi) muon instrument at the ISIS pulsed neutron and muon source is a state-of-the-art spectrometer designed to provide applied magnetic fields up to 5 T for muon studies of condensed matter and molecular systems. The spectrometer is optimised for time-differential muon spin relaxation studies at a pulsed muon source. We describe the challenges involved in its design and construction, detailing, in particular, the magnet and detector performance. Commissioning experiments have been conducted and the results are presented to demonstrate the scientific capabilities of the new instrument.

  20. 'aspect' - a new spectrometer for the measurement of the angular correlation coefficient a in neutron beta decay

    CERN Document Server

    Zimmer, O; Grinten, M G D; Heil, W; Glück, F

    2000-01-01

    The combination of the coefficient a of the antineutrino/electron angular correlation with the beta asymmetry of the neutron provides a sensitive test for scalar and tensor contributions to the electroweak Lagrangian, as well as for right-handed currents. A method is given for measuring a with high sensitivity from the proton recoil spectrum. The method is based on a magnetic spectrometer with electrostatic retardation potentials such as used for searches of the neutrino mass in tritium beta decay. The spectrometer can also be used for similar studies using radioactive nuclei.

  1. High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gatu Johnson, M., E-mail: gatu@psfc.mit.edu; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Séguin, F. H. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Bionta, R. M.; Casey, D. T.; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R.; Sayre, D. B.; Skulina, K.; Yeamans, C. B. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Farrell, M. P.; Hoppe, M.; Kilkenny, J. D.; Reynolds, H. G.; Schoff, M. E. [General Atomics, San Diego, California 92186 (United States)

    2016-11-15

    The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.

  2. Design and construction of a triple-axis crystal neutron spectrometer and performance testing by means of measurements of dispersion relations in copper

    International Nuclear Information System (INIS)

    Fuhrmann, C.

    1979-01-01

    The Triple-Axis Crystal Neutron Spectrometer is the best instrument for the study of lattice dynamics, when the neutron inelastic scattering technique is used. Design, construction and operation of a triple-axis crystal neutron spectrometer, whose construction was recently finished at IEA are described. The design principles employed are directed to mechanical simplicity, facility of construction and flexibility in operation, with no adapted components to industrial applications were used in the construction. The operational characteristics of the spectrometer, such as the neutron wavelenght of the incoming beam and the resolution have been determined. With the purpose to check the performance of IEA Triple-Axis Crystal Neutron Spectrometer, dispersion relation curves for copper, at room temperature, have been measured. The frequency of phonons propagating along three major symmetry directions have been determined. The measurements were carried out operating the Triple-Axis Spectrometer in the 'sup(→)Q-constant' mode. An excelent agreement could be observed between the results obtained in the present experiment and the data for copper presented in the literature. This comparison indicates that the IEA Triple-Axis Crystal Neutron Spectrometer is in good operational conditions and is able to perform original experiments. Details on the experimental procedures for the case of a Triple-Axis Spectrometer operating in 'sup(→)Q-constant' mode are also presented. (Author) [pt

  3. The 2.5-MeV neutron time-of-flight spectrometer TOFOR for experiments at JET

    International Nuclear Information System (INIS)

    Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A.; Kaellne, J.; Weiszflog, M.; Andersson Sunden, E.; Conroy, S.; Ericsson, G.; Hellesen, C.; Ronchi, E.; Sjoestrand, H.; Gorini, G.; Tardocchi, M.; Combo, A.; Cruz, N.; Sousa, J.; Popovichev, S.

    2008-01-01

    A time-of-flight (TOF) spectrometer for measurement of the 2.5-MeV neutron emission from fusion plasmas has been developed and put into use at the JET tokamak. It has been optimized for operation at high rates (TOFOR) for the purpose of performing advanced neutron emission spectroscopy (NES) diagnosis of deuterium plasmas with a focus on the fuel ion motional states for different auxiliary heating scenarios. This requires operation over a large dynamic range, including high rates of >100 kHz with a maximum value of 0.5 MHz for the TOFOR design. This paper describes the design principles and their technical realization. The performance is illustrated with recent neutron TOF spectra recorded for plasmas subjected to different heating scenarios. A true event count rate of 39 kHz has been achieved at about a tenth of the expected neutron yield limit of JET, giving a projected maximum of 400 kHz at peak JET plasma yield. This means that the count rate capability for NES diagnosis of D plasmas has been improved more than an order of magnitude. Another important performance factor is the spectrometer bandwidth, where data have been acquired and analyzed successfully with a response function for neutrons over the energy range 1 to >5 MeV. The implications of instrumental advancement represented by TOFOR are discussed

  4. The 2.5-MeV neutron time-of-flight spectrometer TOFOR for experiments at JET

    International Nuclear Information System (INIS)

    Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A.

    2007-08-01

    A time-of-flight (TOF) spectrometer for measurement of the 2.5-MeV neutron emission from fusion plasmas has been developed and put into use at the JET tokamak. It has been optimized for operation at high rates (TOFOR) for the purpose of performing advanced neutron emission spectroscopy (NES) diagnosis of deuterium plasmas with a focus on the fuel ion motional states for different auxiliary heating scenarios. This requires operation over a large dynamic range including high rates of >100 kHz with a maximum value of 0.5 MHz for the TOFOR design. This paper describes the design principles and their technical realization. The performance is illustrated with recent neutron time-of-flight spectra recorded for plasmas subjected to different heating scenarios. A data acquisition rate of 39 kHz has been achieved at about a tenth of the expected neutron yield limit of JET, giving a projected maximum of 400 kHz at peak JET plasma yield. This means that the count rate capability for NES diagnosis of D plasmas has been improved more than an order of magnitude. Another important performance factor is the spectrometer bandwidth where data have been acquired and analyzed successfully with a response function for neutrons over the energy range 1 to >5 MeV. The implications of instrumental advancement represented by TOFOR are discussed

  5. The 2.5-MeV neutron time-of-flight spectrometer TOFOR for experiments at JET

    Energy Technology Data Exchange (ETDEWEB)

    Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A. (and others)

    2007-08-15

    A time-of-flight (TOF) spectrometer for measurement of the 2.5-MeV neutron emission from fusion plasmas has been developed and put into use at the JET tokamak. It has been optimized for operation at high rates (TOFOR) for the purpose of performing advanced neutron emission spectroscopy (NES) diagnosis of deuterium plasmas with a focus on the fuel ion motional states for different auxiliary heating scenarios. This requires operation over a large dynamic range including high rates of >100 kHz with a maximum value of 0.5 MHz for the TOFOR design. This paper describes the design principles and their technical realization. The performance is illustrated with recent neutron time-of-flight spectra recorded for plasmas subjected to different heating scenarios. A data acquisition rate of 39 kHz has been achieved at about a tenth of the expected neutron yield limit of JET, giving a projected maximum of 400 kHz at peak JET plasma yield. This means that the count rate capability for NES diagnosis of D plasmas has been improved more than an order of magnitude. Another important performance factor is the spectrometer bandwidth where data have been acquired and analyzed successfully with a response function for neutrons over the energy range 1 to >5 MeV. The implications of instrumental advancement represented by TOFOR are discussed.

  6. Neutronics analysis for the ITER core imaging X-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Serikov, Arkady, E-mail: arkady.serikov@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Suarez, Alejandro; Barnsley, Robin; Bertalot, Luciano; O’Connor, Richard; Thenevin, Raphaël; Udintsev, Victor S. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Highlights: • Proposed substantial radiation shielding design improvements of the CIXS system. • Radiation protection of the CIXS Port Interspace (PI) to provide personnel access. • The SDDR at PI was reduced by 100× from 2 mSv/h to 20 microSv/h. • A screen plate as a temporary shield at the CIXS maintenance period has been proposed. • The shadow effect created by a screen plate reduces SDDR by 9×. - Abstract: This paper presents new results of the MCNP neutronics analysis for the core imaging X-ray spectrometer (CIXS) system of the ITER Equatorial Port Plug #17 (EPP#17). Substantial radiation shielding design improvements of the CIXS system have been suggested as the outcomes of this analysis. These suggested improvements allow reaching two major goals: (1) radiation protection of the CIXS Port Interspace (PI) to provide personnel access for maintenance of the vacuum extension flange; (2) reduction of the neutron and gamma loads on the detectors to reduce the need for maintenance itself. By implementing the improvements in our models such as filling void spaces around the CIXS beams with boron carbide and inserting the tungsten collimators in the narrowed beam channel, we were able to reduce the Shut-Down Dose Rate (SDDR) in the PI by 100× from 2 mSv/h in the original CIXS design to 20 microSv/h. In case of non-changed MCNP geometry, the D1S method was applied in calculations of SDDR. To allow the maintenance access to the flange, a part of shielding was removed, therefore the R2Smesh methodology was applied instead of D1S. During the maintenance access of CIXS from the PI side, a screen plate was proposed to introduce behind which a worker receives much less SDDR.

  7. New components for the neutron spectrometer SV5c at the 10H channel of the research reactor FRJ2

    International Nuclear Information System (INIS)

    Stockmeyer, R.

    1991-02-01

    The following new components have been installed at the neutron time-of-flight spectrometer SV5c: 1. Monochromator with devices for tilting and rotating 10 crystal. The fine-adjustment of the crystal orientation can be done with a computer program which maximizes the neutron intensity at the sample position. 2. 128 x 512 multi-channel time-of-flight electronic 3. Computerized equipment for measuring thermal properties of a sample (adsorption isotherm, sample transmission) 4. Data aquisition, data handling and experiment control software coded in ASYST. (orig.)

  8. Tandem analyzer crystals system doubles counting rate for Bonse Hart ultra-small-angle neutron-scattering spectrometer

    Science.gov (United States)

    Yamaguchi, Daisuke; Koizumi, Satoshi; Motokawa, Ryuhei; Kumada, Takayuki; Aizawa, Kazuya; Hashimoto, Takeji

    2006-11-01

    A new tandem analyzer crystals system was introduced on Bonse-Hart ultra-small-angle neutron-scattering spectrometer at research reactor JRR-3, Tokai, Japan. Conventional Bonse-Hart setup consumes a considerable time to measure a scattering profile of whole q range (2×10 -4 nm -1neutrons from the sample and having different q are measured step by step. To overcome this difficulty two analyzer channel-cut silicon perfect crystals were settled in tandem and each of them diffracted the scattering of different q. In consequence, a simultaneous detection at two different q positions was realized and the measurement time was reduced to half.

  9. Focusing and polarized neutron ultra-small-angle scattering spectrometer (SANS-J-II) at Research Reactor JRR3, Japan

    International Nuclear Information System (INIS)

    Koizumi, Satoshi; Iwase, Hiroki; Suzuki, Jun-ichi; Oku, Takayuki; Motokawa, Ryuhei; Sasao, Hajime; Tanaka, Hirokazu; Yamaguchi, Daisuke; Shimizu, Hirohiko M.; Hashimoto, Takeji

    2006-01-01

    By employing focusing lenses of sextupole permanent magnet and biconcave MgF 2 crystal, and high-resolution photomultiplier, SANS-J (pinhole small-angle neutron scattering spectrometer at research reactor JRR3, Tokai) was reconstructed to focusing and polarized neutron ultra-small-angle scattering spectrometer (SANS-J-II). Consequently, an accessible minimum wave number q min was improved from 3x10 -3 A -1 to 3x10 -4 A -1 . Furthermore, we added 3 He sub-detectors with an analyzer super mirror at a sample position. With this setup, we perform polarization analysis at high q (>0.2 A -1 ) in order to quantitatively discriminate spin incoherent scattering from hydrogen or to perform spin contrast variation, by a dynamic nuclear polarization method (>0.2 A -1 )

  10. Characterization of the neutron field at the ISIS-VESUVIO facility by means of a bonner sphere spectrometer

    Science.gov (United States)

    Bedogni, Roberto; Esposito, Adolfo; Andreani, Carla; Senesi, Roberto; De Pascale, Maria Pia; Picozza, Piergiorgio; Pietropaolo, Antonino; Gorini, Giuseppe; Frost, Christopher D.; Ansell, Stewart

    2009-12-01

    One of the more actual and promising fields of applied neutron physics is the investigation of the malfunctions induced by high-energy neutrons naturally present in the atmosphere in electronic devices, called single event effects (SEE). These studies are of primary importance for the design of devices that have to fulfill high reliability requirements and those that are likely to be exposed to enhanced levels of cosmic rays background, e.g. in aerospace and avionic applications. Particle accelerators-driven neutron sources constitute valuable irradiation facilities for these purposes as they provide an opportunity for accelerated testing of the effects of these naturally occurring neutrons, provided the neutron spectrum is comparable with the atmospheric one and the neutron fields are known with high accuracy. The latter can be achieved through the use of appropriate radiation transport codes and neutron spectrometry techniques. In view of the design and construction of CHIPIR, a dedicated beam line for SEE studies at the ISIS pulsed neutron source second target station (UK) [1] ( http://ts-2.isis.rl.ac.uk/instruments/phase2/index.htm), a spectrometric characterization was performed on the VESUVIO beamline [2] (Senesi et al.,2000). The spectrometric technique was the bonner sphere spectrometer (BSS), widely used to determine neutron spectra and dose quantities around high-energy accelerators. The experimental campaign provided a complete spectrometric investigation of the VESUVIO neutron beam, allowing the integral quantities (total fluence rate, fraction of fluence in given energy intervals) to be estimated with uncertainties lower than 10%.

  11. Design of a Ge-NaI(Tl) Compton suppression spectrometer and its use in neutron activation analysis

    International Nuclear Information System (INIS)

    Petra, M.; Swift, G.; Landsberger, S.

    1990-01-01

    A Compton suppression spectrometer consisting of a germanium detector surrounded by a NaI(Tl) shield and its performance are described. The system reduces the Compton continuum, thus making possible the identification of low-intensity peaks. This allows the determination of small amounts of various elements in biological and environmental materials following neutron activation. Representative results for arsenic in biological materials are presented. (orig.)

  12. The multianalyser system of the three axes neutron spectrometer PUMA: Pilot experiments with the innovative multiplex technique

    Science.gov (United States)

    Sobolev, Oleg; Hoffmann, Ron; Gibhardt, Holger; Jünke, Norbert; Knorr, Andreas; Meyer, Volker; Eckold, Götz

    2015-02-01

    A new type of multiplex technique for three axes neutron spectrometers has been realized and successfully commissioned at the PUMA spectrometer at FRM II. Consisting of eleven analyser-detector channels which can be configured individually, this technique is especially suitable for kinetic experiments where a single excitation spectrum is recorded as a function of time without the need to move the spectrometer. On a time-scale of seconds an entire spectrum can be recorded thus allowing users to monitor changes during fast kinetic processes in single shot experiments without the need for stroboscopic techniques. Moreover, the multianalyser system provides an efficient and rapid tool for mapping excitations in (Q,ω)-space. The results of pilot experiments demonstrate the performance of this new technique and a user-friendly software is presented which assists users during their experiments.

  13. Determination of workplace neutron spectra at a high energy hadron accelerator using active and passive Bonner sphere spectrometers

    International Nuclear Information System (INIS)

    Bedogni, R.; Esposito, A.; Chiti, M.

    2008-01-01

    In the framework of the 2006 experimental benchmark organized at the GSI (Darmstadt, Germany) by the EC CONRAD network, a neutron dosimetry intercomparison was performed in a workplace field around a carbon target hit by 400 MeV/u 12 C ions. The radiation protection group of the INFN-LNF participated to the intercomparison with a Bonner sphere spectrometer equipped with an active 6 LiI(Eu) scintillator and a set of passive detectors, namely MCP-6s (80mgcm -2 )/MCP-7 TLD pairs from TLD Poland. Both active and passive spectrometers, independently tested and calibrated, were used to determine the field and dosimetric quantities in the measurement point. The FRUIT unfolding code, developed at the INFN-LNF radiation protection group, was used to unfold the raw BSS data. This paper compares the results of the active or passive spectrometers, obtaining a satisfactory agreement in terms of both spectrum shape and value of the integral quantities, as the neutron fluence or the ambient dose equivalent. These results allow qualifying the BSS based on TLD pairs as a reliable passive method to be used around high energy particle accelerators even in low dose rate areas. This is particularly useful in those workplaces where the active instruments could be disturbed by the presence of pulsed fields, large photon fluence or electromagnetic noise

  14. Determination of phosphorous in cannabis by neutron activation analysis - measurement of 32P Cerenkov radiation by liquid scintillaton spectrometer

    International Nuclear Information System (INIS)

    Shinogi, M.; Mori, I.

    1977-05-01

    Thermal neutron activaton analysis with measurement of 32 P Cerenkov radiation by liquid scintillation spectrometer was used to determine phosphorus in cannabis. After irradiation of the sample, wet ashing was carried out with conc. nitric acid and 70% perchloric acid. The solution in l M perchloric acid transferred to an inorganic ion-exchange column containing acid aluminium oxide and phosphorus was quantitatively eluted with 1M hydrofluoric acid. The 32 P radioactivity of each fraction of the eluate was counted with Cerenkov radiation by a liquid scintillation spectrometer from 2 to 7 weeks after the irradiation. The activity curve decayed with 32 P half-life. The isotope channel ratio technique was applied for the quench correction. The optimal experimental conditions for chemical separation of phosphorus and for measuring the 32 P Cerenkov radiation were also examined. (Author)

  15. Neutron-activation determination of phosphorus and sulfur in molybdenum and tungsten with the help of a beta-spectrometer

    International Nuclear Information System (INIS)

    Usmanova, M.M.; Mukhamedshina, N.M.; Kim, R.D.; Kaganov, L.K.

    1987-01-01

    An instrumental variant of the neutron-activation determination of phosphorus and sulfur in molybdenum and tungsten was developed with the help of a β-spectrometer that makes it possible to discriminate the participation of the 99 Mo and 187 W radioisotopes in the overall activity of the sample. It was shown that simultaneous determination of P and S on the basis of the 32 P radioisotope is feasible if their contents are comparable or are not different by more than 1-1.5 orders of magnitude, and then the maximum relative standard deviation is 0.15

  16. Calibration of scintillation-light filters for neutron time-of-flight spectrometers at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sayre, D. B., E-mail: sayre4@llnl.gov; Barbosa, F.; Caggiano, J. A.; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); DiPuccio, V. N.; Weber, F. A. [National Security Technologies, Livermore, California 94551 (United States)

    2016-11-15

    Sixty-four neutral density filters constructed of metal plates with 88 apertures of varying diameter have been radiographed with a soft x-ray source and CCD camera at National Security Technologies, Livermore. An analysis of the radiographs fits the radial dependence of the apertures’ image intensities to sigmoid functions, which can describe the rapidly decreasing intensity towards the apertures’ edges. The fitted image intensities determine the relative attenuation value of each filter. Absolute attenuation values of several imaged filters, measured in situ during calibration experiments, normalize the relative quantities which are now used in analyses of neutron spectrometer data at the National Ignition Facility.

  17. Novel type of neutron polarization analysis using the multianalyzer-equipment of the three-axes spectrometer PUMA

    Science.gov (United States)

    Schwesig, Steffen; Maity, Avishek; Sobolev, Oleg; Ziegler, Fabian; Eckold, Götz

    2018-01-01

    The combination of polarization analysis and multianalyzer system available at the three axes spectrometer PUMA@FRM II allows the simultaneous determination of both spin states of the scattered neutrons and the absolute value of the polarization. The present paper describes the technical details along with the basic formalism used for the precise calibration. Moreover, the performance of this method is illustrated by several test experiments including first polarized inelastic studies of the magnetic excitations of CuO in the multiferroic and the uniaxial antiferromagnetic phases.

  18. Measurement of the electron antineutrino angular correlation coefficient a with the neutron decay spectrometer aSPECT

    International Nuclear Information System (INIS)

    Simson, Martin

    2010-01-01

    This thesis describes measurements with the retardation spectrometer aSPECT at the Institut Laue-Langevin in Grenoble. The goal of the measurement is to determine the angular correlation coefficient a from the form of the proton recoil spectrum in the decay of the free neutron in order to determine a precise value for the ratio of the weak axial vector and vector coupling constants of the nucleon. A big improvement was achieved with the use of a silicon drift detector which was used here for the first time to detect low energetic protons. A saturation effect of the electronics that was only discovered during the analysis of the data from neutron decay proved to be not correctable. The findings from analysis, simulations and test experiments gained in this work should allow a measurement of a with high precision in a future beamtime. (orig.)

  19. Measurement of the electron antineutrino angular correlation coefficient a with the neutron decay spectrometer aSPECT

    Energy Technology Data Exchange (ETDEWEB)

    Simson, Martin

    2010-09-21

    This thesis describes measurements with the retardation spectrometer aSPECT at the Institut Laue-Langevin in Grenoble. The goal of the measurement is to determine the angular correlation coefficient a from the form of the proton recoil spectrum in the decay of the free neutron in order to determine a precise value for the ratio of the weak axial vector and vector coupling constants of the nucleon. A big improvement was achieved with the use of a silicon drift detector which was used here for the first time to detect low energetic protons. A saturation effect of the electronics that was only discovered during the analysis of the data from neutron decay proved to be not correctable. The findings from analysis, simulations and test experiments gained in this work should allow a measurement of a with high precision in a future beamtime. (orig.)

  20. Tandem analyzer crystals system doubles counting rate for Bonse-Hart ultra-small-angle neutron-scattering spectrometer

    International Nuclear Information System (INIS)

    Yamaguchi, Daisuke; Koizumi, Satoshi; Motokawa, Ryuhei; Kumada, Takayuki; Aizawa, Kazuya; Hashimoto, Takeji

    2006-01-01

    A new tandem analyzer crystals system was introduced on Bonse-Hart ultra-small-angle neutron-scattering spectrometer at research reactor JRR-3, Tokai, Japan. Conventional Bonse-Hart setup consumes a considerable time to measure a scattering profile of whole q range (2x10 -4 nm -1 -2 nm -1 , where q denotes magnitude of scattering vector) due to the step scan system, in which the scattered neutrons from the sample and having different q are measured step by step. To overcome this difficulty two analyzer channel-cut silicon perfect crystals were settled in tandem and each of them diffracted the scattering of different q. In consequence, a simultaneous detection at two different q positions was realized and the measurement time was reduced to half

  1. Measurement of the electron-antineutrino angular correlation coefficient a in neutron beta decay with the spectrometer aSPECT

    International Nuclear Information System (INIS)

    Petzoldt, G.

    2007-01-01

    In the four beam times we performed at the FRM-II, we were able to show that the spectrometer works in principle and that a determination of a with it is possible. A set of routines has been written for decoding and analyzing the raw data. The routines are written in C using the ROOT libraries and can be easily adapted or expanded. We have found a reliable way to extract the proton count rates from the data by building pulseheight spectra for each measurement, subtracting background measurements from those and fitting the resulting peak with a Gaussian. The background of the measurements was studied in detail. The background caused by electrons from neutron decay is very well understood and conforms quantitatively to our expectation. Due to the spatial resolution of our detector and the time resolution provided by our DAQ electronics, we were able to study correlated electron-proton pairs from one neutron decay event. They form a clearly visible peak in a time- and channel-distance spectrum, which can be shifted in the channel-dimension by varying the voltages applied to the lower and upper E x B electrodes. Performing a pulseheight analysis for both involved particles allowed us to obtain a fairly clean energy spectrum of the background caused by electrons from neutron decay in our detector. Using these correlations for data analysis may be of interest for future neutron decay experiments which use segmented detectors. (orig.)

  2. Measurement of the electron-antineutrino angular correlation coefficient a in neutron beta decay with the spectrometer aSPECT

    Energy Technology Data Exchange (ETDEWEB)

    Petzoldt, G.

    2007-08-29

    In the four beam times we performed at the FRM-II, we were able to show that the spectrometer works in principle and that a determination of a with it is possible. A set of routines has been written for decoding and analyzing the raw data. The routines are written in C using the ROOT libraries and can be easily adapted or expanded. We have found a reliable way to extract the proton count rates from the data by building pulseheight spectra for each measurement, subtracting background measurements from those and fitting the resulting peak with a Gaussian. The background of the measurements was studied in detail. The background caused by electrons from neutron decay is very well understood and conforms quantitatively to our expectation. Due to the spatial resolution of our detector and the time resolution provided by our DAQ electronics, we were able to study correlated electron-proton pairs from one neutron decay event. They form a clearly visible peak in a time- and channel-distance spectrum, which can be shifted in the channel-dimension by varying the voltages applied to the lower and upper E x B electrodes. Performing a pulseheight analysis for both involved particles allowed us to obtain a fairly clean energy spectrum of the background caused by electrons from neutron decay in our detector. Using these correlations for data analysis may be of interest for future neutron decay experiments which use segmented detectors. (orig.)

  3. Installation of a triple axis spectrometer at Siloe for neutron inelastic scattering experiments

    International Nuclear Information System (INIS)

    Roudaut, E.; Rossat-Mignod, J.

    1975-01-01

    An old DN1 power spectrometer was converted to an inelastic spectrometer in order to widen the research possibilities of the laboratory, especially in the field of spin waves. The installation of the shielding-spectrometer unit was finished at the end of 1974 and the piloting programmes were established and tested. The performance and possibilities of the apparatus were checked by reproducing two kinds of experiment: determination of spin wave dispersion curves in magnetite; determination of crystal field levels in the compounds Ersub(0.2)Ysub(0.8)Cu and HoRh [fr

  4. First test of SP{sup 2}: A novel active neutron spectrometer condensing the functionality of Bonner spheres in a single moderator

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R. [INFN-LNF Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy); Bortot, D. [Politecnico di Milano—Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano (Italy); INFN—sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Buonomo, B.; Esposito, A. [INFN-LNF Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy); Gómez-Ros, J.M. [INFN-LNF Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Introini, M.V.; Lorenzoli, M.; Pola, A. [Politecnico di Milano—Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano (Italy); INFN—sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Sacco, D. [INFN-LNF Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy); INAIL—DPIA Via di Fontana Candida n.1, 00040 Monteporzio C. (Italy)

    2014-12-11

    The NESCOFI@BTF (2011–2013) international collaboration was established to develop realtime neutron spectrometers to simultaneously cover all energy components of neutron fields, from thermal up to hundreds MeV. This communication concerns a new spherical spectrometer, called SP^2, which condenses the functionality of an Extended Range Bonner Sphere Spectrometer (ERBSS) into a single moderator embedding multiple active thermal neutron detectors. The possibility of achieving the complete spectrometric information in a single exposure constitutes a great advantage compared to the ERBSS. The first experimental test of the instrument, performed with a reference 241Am–Be source in different irradiation geometries, is described. The agreement between observed and simulated response is satisfactory for all tested geometries.

  5. The upgraded cold neutron three-axis spectrometer FLEXX at BER II at HZB

    DEFF Research Database (Denmark)

    Duc Le, Manh; Skoulatos, Markos; Quintero-Castro, Diana Lucía

    2014-01-01

    Larmor labeling is seen as one of the key ingredients in the development of novel neutron instrumentation. FLEXX puts special emphasis on exploiting the neutron resonance spin echo (NRSE) technique for high-resolution spectroscopy on dispersive quasi-particle excitations. This enables unique...... capabilities for quantum magnetism, heavy-fermion systems and unconventional superconductivity. For example inelastic experiments in magnetic fields up to 17 T are now proven to be feasible. Energy research with inelastic neutron instruments will be strengthened through inhouse research, thereby fostering...

  6. Characterization of one-dimensional position sensitive detectors with improved efficiency and position resolution for neutron spectrometers.

    Science.gov (United States)

    Desai, S S; Shaikh, A M

    2007-02-01

    Development and characterization of one-dimentional (1D) position sensitive detectors (PSDs) with improved efficiency and position resolution for neutron scattering applications are reported. The PSDs are characterized for energy resolution, count rate capability, sensitivity, efficiency, position resolution, and uniformity of response over the sensitive length. The studies are carried out to verify the dependence of position resolution on detector geometry, electronic noise, and stopping power of the fill gas. One of the PSDs is mounted on the small angle neutron scattering spectrometer and spectra from CTAB micelle sample are recorded using 5.4 A neutrons. A gain of factors 1.1 and 1.2 is obtained compared to earlier in house made 1D PSD and LND-made 1D PSD, respectively. The diffraction patterns from standard vanadium, nickel, and silicon samples are recorded on a powder diffractometer using newly designed PSDs. Gain in efficiency obtained at shorter wavelength of 0.783 A is by a factor of 1.6. All high pressure PSDs show improvement in the position resolution by 2-3 mm. It is observed that 1D PSD filled with isobutane as stopping gas improves the gamma tolerance and position resolution at lower partial pressures as compared to Kr. It is advantageous to use two or more 36C-type PSDs stacked together. It is economic and gives better efficiency due to scanning more beam height.

  7. Automatic detection of recoil proton tracks and background rejection in liquid scintillator-micro-capillary-array fast neutron spectrometer

    Science.gov (United States)

    Mor, I.; Vartsky, D.; Dangendorf, V.; Tittelmeier, K.; Goldberg, M. B.; Bar, D.; Brandis, M.

    2017-12-01

    We describe results on automatic detection of fast-neutron induced recoil-proton tracks in micro-capillary bundles filled with organic liquid scintillator, viewed by an intensified CCD camera. This imaging neutron spectrometer was developed for high position-resolution (few tens of μ m) imaging and medium-quality energy spectroscopy of neutrons in the energy range 2–20 MeV. In addition to recoil proton events which display a continuous extended track structure, CCD images include also a multitude of isolated spots of varying intensity ("blobs") that originate from several different sources, such as fragmented proton tracks, electrons from gamma-rays, short heavy-ion tracks, as well as events and noise that occur in the image intensifier and CCD. In order to identify the extended-track recoil proton events and separate them from these background events, a computerized, rapid and automatic track-recognition procedure was developed. Based on the analysis of track parameters such as: track area, light intensity, track length and width, the method is capable of distinguishing few recoil protons from the surrounding numerous background events typically found in each CCD frame.

  8. Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by ≈1 MJ plasma focus

    Czech Academy of Sciences Publication Activity Database

    Králík, M.; Krása, Josef; Velyhan, Andriy; Scholz, M.; Ivanova-Stanik, I.M.; Bienkowska, B.; Miklaszewski, R.; Schmidt, H.; Řezáč, K.; Klír, D.; Kravárik, J.; Kubeš, P.

    2010-01-01

    Roč. 81, č. 11 (2010), 113503/1-113503/5 ISSN 0034-6748 R&D Projects: GA MŠk LA08024 Grant - others:FP-6 EU(XE) RITA-CT2006-26095 Institutional research plan: CEZ:AV0Z10100523 Keywords : plasma focus * fusion DD neutrons * Bonner sphere spectrometer * energy spectra of scattered neutrons * unfolded and calculated spectra Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.598, year: 2010

  9. The vTAS suite: A simulator for classical and multiplexed three-axis neutron spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, M., E-mail: boehm@ill.eu [Institut Laue-Langevin, BP 156, F-38042 Grenoble cedex 9 (France); Filhol, A. [Institut Laue-Langevin, BP 156, F-38042 Grenoble cedex 9 (France); Raoul, Y. [Institut Laue-Langevin, BP 156, F-38042 Grenoble cedex 9 (France); Juelich Centre for Neutron Science, Forschungszentrum Juelich, Outstation at Institut Laue-Langevin, 38042 Grenoble (France); Kulda, J. [Institut Laue-Langevin, BP 156, F-38042 Grenoble cedex 9 (France); Schmidt, W.; Schmalzl, K. [Juelich Centre for Neutron Science, Forschungszentrum Juelich, Outstation at Institut Laue-Langevin, 38042 Grenoble (France); Farhi, E. [Institut Laue-Langevin, BP 156, F-38042 Grenoble cedex 9 (France)

    2013-01-01

    The vTAS suite provides graphical assistance to prepare and perform inelastic neutron scattering experiments on a TAS instrument, including latest multiplexed instrumental configurations, such as FlatCone, IMPS and UFO. The interactive display allows for flexible translation between instrument positions in real space and neutron scattering conditions represented in reciprocal space. It is a platform independent public domain software tool, available for download from the website of the Institut Laue Langevin (ILL).

  10. FOCUS: time-of-flight spectrometer for cold neutrons at SINQ

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, S.; Mesot, J. [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland); Hempelmann, R. [Saarbruecken Univ., Physical Chemistry, Saarbruecken (Germany)

    1996-11-01

    The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.

  11. Development of Data Acquisition and Measurement Software for Neutron Triple Axis Spectrometer at BATAN-Serpong, Indonesia

    Directory of Open Access Journals (Sweden)

    B Bharoto

    2017-06-01

    Full Text Available The Neutron Scattering Laboratory at the National Nuclear Energy Agency of Indonesia (BATAN possesses several neutron beam instruments for materials science research. One of the instruments is a neutron triple-axis spectrometer (TAS. Due to the malfunction of the main computer, the original main control system had to be replaced with a new one. For this reason, a new data acquisition and measurement software program based on GNU C++ programming language was developed for restoring the spectrometer's functionality. However, using the resulting control system, triple-axis mode experiments were very difficult to perform and their types that can be performed were limited. In order to conduct the experiments more effectively and efficiently, several improvements in both hardware and software have been developed. The Visual Basic programming language was used in developing the data acquisition and measurement software that makes it possible for all motors to move simultaneously, so that the time spent for the experiments is reduced significantly. Also, programmable motor controller cards were used for driving all the 23 motors of the instrument. All the 23 axes can be controlled by clicking the appropriate buttons or inputting text command in the main window of the software's user interface. The software has also been used to perform an elastic experiment, as well as an inelastic experiment for investigating the phenomenon of phonon. The software developed is more user friendly than the older ones, since the spectrometer status and the experiment results can be displayed in real time at the windows, and it also makes experiments more effective and efficient since the experiments can be automated and run without any user intervention until the experiments finish. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso

  12. Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sungil

    2006-01-01

    The Cold Neutron Research Facility (CNRF) project carried out by Korea Atomic Energy Research Institute (KAERI) is an effort to bring cold neutron instrumentation to Korea's only large scale research reactor, HANARO, located in Daejeon. As part of the CNRF project, a cold neutron triple-axis spectrometer (Cold-TAS) is being developed along with other five: 40 m long and 12 m long small angle neutron scattering instruments (40m-SANS and 12m-SANS), disk-chopper time-of-flight spectrometer (DC-ToF), Bio- Reflectometer (Bio-REF) and the reflectometer with vertical sample geometry (REF-V). For those cold neutron instruments, the performance of an individual instrument depends not only on its design but also on the guide that feeds cold neutrons to the instrument. Therefore, the quality of the neutron flux at an instrument position has to be checked with the specification of the instrument. As for the Cold-TAS, since the instrument requires a tall beam and a high flux of short wavelength neutrons, it was tentatively decided that it would use the cold guide 4 (CG4). The detailed specification of the guide is listed. Checking the neutron flux of the guide at the instrument position is the obvious next step

  13. Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko; Eriksson, J.

    2014-01-01

    spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly...

  14. A position-sensitive neutron spectrometer/dosimeter based on pressurized superheated drop (bubble) detectors

    Energy Technology Data Exchange (ETDEWEB)

    D' Errico, F. E-mail: francesco.derrico@yale.edu; Nath, R.; Holland, S.K.; Lamba, M.; Patz, S.; Rivard, M.J

    2002-01-01

    A position-sensitive, superheated emulsion chamber (SEC) is introduced for three-dimensional (3D) spectrometry and dosimetry of fast neutrons. The detector is based on a fine suspension of octafluorocyclobutane droplets emulsified in a tissue-equivalent gel. This gel is highly viscous and immobilizes the bubbles at the location of their formation. At an operating temperature of 35 deg.C, the droplets are moderately superheated and their evaporation is nucleated by the densely ionizing products of fast neutron interactions, with no response to sparsely ionizing radiations. Thus, when a neutron emitter such as a {sup 252}Cf brachytherapy source is inserted in the SEC, a bubble distribution forms around the source and makes the neutron field visible. The SEC is operated at different externally applied pressures that correspond to different response thresholds. These responses form a virtually orthogonal matrix which is suitable for spectrometry and allows the use of effective few channel unfolding procedures, yielding the spatial dependence of absorbed dose and neutron energy spectra in-tissue. Bubble spatial distributions in the chamber can be determined through optical tomography or magnetic resonance imaging (MRI). A 3D, steady-state MRI method has proven particularly effective for this purpose. After the imaging, the SEC can be pressurized above the halocarbon vapor tension in order to recondense the bubbles to the liquid phase. Within a few minutes, the device is annealed and ready to be used again for repeated measurements improving the bubble counting statistics.

  15. A position-sensitive neutron spectrometer/dosimeter based on pressurized superheated drop (bubble) detectors

    Science.gov (United States)

    d'Errico, F.; Nath, R.; Holland, S. K.; Lamba, M.; Patz, S.; Rivard, M. J.

    2002-01-01

    A position-sensitive, superheated emulsion chamber (SEC) is introduced for three-dimensional (3D) spectrometry and dosimetry of fast neutrons. The detector is based on a fine suspension of octafluorocyclobutane droplets emulsified in a tissue-equivalent gel. This gel is highly viscous and immobilizes the bubbles at the location of their formation. At an operating temperature of 35°C, the droplets are moderately superheated and their evaporation is nucleated by the densely ionizing products of fast neutron interactions, with no response to sparsely ionizing radiations. Thus, when a neutron emitter such as a 252Cf brachytherapy source is inserted in the SEC, a bubble distribution forms around the source and makes the neutron field visible. The SEC is operated at different externally applied pressures that correspond to different response thresholds. These responses form a virtually orthogonal matrix which is suitable for spectrometry and allows the use of effective few channel unfolding procedures, yielding the spatial dependence of absorbed dose and neutron energy spectra in-tissue. Bubble spatial distributions in the chamber can be determined through optical tomography or magnetic resonance imaging (MRI). A 3D, steady-state MRI method has proven particularly effective for this purpose. After the imaging, the SEC can be pressurized above the halocarbon vapor tension in order to recondense the bubbles to the liquid phase. Within a few minutes, the device is annealed and ready to be used again for repeated measurements improving the bubble counting statistics.

  16. Measurement of the proton recoil spectrum in neutron beta decay with the spectrometer aSPECT. Study of systematic effects

    International Nuclear Information System (INIS)

    Konrad, Gertrud Emilie

    2012-01-01

    Free neutron decay, n→pe anti ν e , is the simplest nuclear beta decay, well described as a purely left-handed, vector minus axial-vector interaction within the framework of the Standard Model (SM) of elementary particles and fields. Due to its highly precise theoretical description, neutron beta decay data can be used to test certain extensions to the SM. Possible extensions require, e.g., new symmetry concepts like left-right symmetry, new particles, leptoquarks, supersymmetry, or the like. Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology, and are generally complementary to direct searches for new physics beyond the SM in high-energy physics. In this doctoral thesis, a measurement of the proton recoil spectrum with the neutron decay spectrometer aSPECT is described. From the proton spectrum the antineutrinoelectron angular correlation coefficient a can be derived. In our first beam time at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz in Munich, Germany (2005-2006), background instabilities due to particle trapping and the electronic noise level of the proton detector prevented us from presenting a new value for a. In the latest beam time at the Institut Laue-Langevin (ILL) in Grenoble, France (2007-2008), the trapped particle background has been reduced sufficiently and the electronic noise problem has essentially been solved. For the first time, a silicon drift detector was used. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The target figure of the latest beam time was a new value for a with a total relative error well below the present literature value of 4 %. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, which are too high to determine a meaningful result. The present doctoral

  17. Measurement of the proton recoil spectrum in neutron beta decay with the spectrometer aSPECT. Study of systematic effects

    Energy Technology Data Exchange (ETDEWEB)

    Konrad, Gertrud Emilie

    2012-01-24

    Free neutron decay, n{yields}pe anti {nu}{sub e}, is the simplest nuclear beta decay, well described as a purely left-handed, vector minus axial-vector interaction within the framework of the Standard Model (SM) of elementary particles and fields. Due to its highly precise theoretical description, neutron beta decay data can be used to test certain extensions to the SM. Possible extensions require, e.g., new symmetry concepts like left-right symmetry, new particles, leptoquarks, supersymmetry, or the like. Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology, and are generally complementary to direct searches for new physics beyond the SM in high-energy physics. In this doctoral thesis, a measurement of the proton recoil spectrum with the neutron decay spectrometer aSPECT is described. From the proton spectrum the antineutrinoelectron angular correlation coefficient a can be derived. In our first beam time at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz in Munich, Germany (2005-2006), background instabilities due to particle trapping and the electronic noise level of the proton detector prevented us from presenting a new value for a. In the latest beam time at the Institut Laue-Langevin (ILL) in Grenoble, France (2007-2008), the trapped particle background has been reduced sufficiently and the electronic noise problem has essentially been solved. For the first time, a silicon drift detector was used. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The target figure of the latest beam time was a new value for a with a total relative error well below the present literature value of 4 %. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, which are too high to determine a meaningful result. The present

  18. Deep inelastic neutron scattering on 207Pb and NaHF2 as a test of a detectors array on the VESUVIO spectrometer

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Senesi, R.

    2008-01-01

    A prototype array of resonance detectors for deep inelastic neutron scattering experiments has been installed on the VESUVIO spectrometer, at the ISIS spallation neutron source. Deep inelastic neutron scattering measurements on a reference lead sample and on NaHF 2 molecular system are presented. Despite on an explorative level, the results obtained for the values of mean kinetic energy k > are found in good agreement with the theoretical predictions, thus assessing the potential capability of the device for a routine use on the instrument

  19. Deep inelastic neutron scattering on {sup 207}Pb and NaHF{sub 2} as a test of a detectors array on the VESUVIO spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Pietropaolo, A. [Universita degli Studi di Roma Tor Vergata, Dipartimento di Fisica and Centro NAST - Nanoscienze and Nanotecnologie and Strumentazione, via della Ricerca Scientifica 1, 00133 Rome (Italy)], E-mail: antonino.pietropaolo@roma2.infn.it; Senesi, R. [Universita degli Studi di Roma Tor Vergata, Dipartimento di Fisica and Centro NAST - Nanoscienze and Nanotecnologie and Strumentazione, via della Ricerca Scientifica 1, 00133 Rome (Italy)

    2008-01-11

    A prototype array of resonance detectors for deep inelastic neutron scattering experiments has been installed on the VESUVIO spectrometer, at the ISIS spallation neutron source. Deep inelastic neutron scattering measurements on a reference lead sample and on NaHF{sub 2} molecular system are presented. Despite on an explorative level, the results obtained for the values of mean kinetic energy are found in good agreement with the theoretical predictions, thus assessing the potential capability of the device for a routine use on the instrument.

  20. Primary Data Treatment Software for Position-Sensitive Detector of Small-Angle Neutron Scattering Spectrometer in the Isotropic Pattern Scattering Case

    Science.gov (United States)

    Soloviev, Alexei; Kutuzov, Sergei; Ivankov, Olexander; Kuklin, Alexander

    2018-02-01

    A new data converter has been created for the new position-sensitive detector (PSD) of small-angle neutron scattering (SANS) spectrometer YuMO. In the isotropic pattern scattering case, it provides the possibility for processing PSD data with the SAS data processing program that has already been in use.

  1. Primary Data Treatment Software for Position-Sensitive Detector of Small-Angle Neutron Scattering Spectrometer in the Isotropic Pattern Scattering Case

    Directory of Open Access Journals (Sweden)

    Soloviev Alexei

    2018-01-01

    Full Text Available A new data converter has been created for the new position-sensitive detector (PSD of small-angle neutron scattering (SANS spectrometer YuMO. In the isotropic pattern scattering case, it provides the possibility for processing PSD data with the SAS data processing program that has already been in use.

  2. Bayesian and maximum entropy methods for fusion diagnostic measurements with compact neutron spectrometers

    International Nuclear Information System (INIS)

    Reginatto, Marcel; Zimbal, Andreas

    2008-01-01

    In applications of neutron spectrometry to fusion diagnostics, it is advantageous to use methods of data analysis which can extract information from the spectrum that is directly related to the parameters of interest that describe the plasma. We present here methods of data analysis which were developed with this goal in mind, and which were applied to spectrometric measurements made with an organic liquid scintillation detector (type NE213). In our approach, we combine Bayesian parameter estimation methods and unfolding methods based on the maximum entropy principle. This two-step method allows us to optimize the analysis of the data depending on the type of information that we want to extract from the measurements. To illustrate these methods, we analyze neutron measurements made at the PTB accelerator under controlled conditions, using accelerator-produced neutron beams. Although the methods have been chosen with a specific application in mind, they are general enough to be useful for many other types of measurements

  3. Neutron scattering studies of the dynamics of biopolymer-water systems using pulsed-source spectrometers

    International Nuclear Information System (INIS)

    Middendorf, H.D.; Miller, A.

    1994-01-01

    Energy-resolving neutron scattering techniques provide spatiotemporal data suitable for testing and refining analytical models or computer simulations of a variety of dynamical processes in biomolecular systems. This paper reviews experimental work on hydrated biopolymers at ISIS, the UK Pulsed Neutron Facility. Following an outline of basic concepts and a summary of the new instrumental capabilities, the progress made is illustrated by results from recent experiments in two areas: quasi- elastic scattering from highly hydrated polysaccharide gels (agarose and hyaluronate), and inelastic scattering from vibrational modes of slightly hydrated collagen fibers

  4. The performance of neutron spectrometers AR a long-pulse spallation source

    International Nuclear Information System (INIS)

    Pynn, R.; Daemen, L.L.

    1995-01-01

    At a recent workshop at Lawrence Berkeley National Laboratory members of the international neutron scattering community discussed the performance to be anticipated from neutron scattering instruments installed at a 1 MW long-pulse spallation source (LPSS). Although the report of this workshop is long, its principal conclusions can be easily summarised and almost as easily understood. This article presents such a synthesis for a 60 Hz LPSS with 1 msec proton pulses. We discuss some of the limitations of the workshop conclusions and suggest a simple analysis of the performance differences that might be expected between short- and long-pulse sources both of which exploit coupled moderators

  5. Time lens for high-resolution neutron time-of-flight spectrometers

    International Nuclear Information System (INIS)

    Baumann, K.; Gaehler, R.; Grigoriev, P.; Kats, E.I.

    2005-01-01

    We examine in analytic and numeric ways the imaging effects of temporal neutron lenses created by traveling magnetic fields. For fields of parabolic shape we derive the imaging equations, investigate the time magnification, the evolution of the phase-space element, the gain factor, and the effect of finite beam size. The main aberration effects are calculated numerically. The system is technologically feasible and should convert neutron time-of-flight instruments from pinhole to imaging configuration in time, thus enhancing intensity and/or time resolution. Further fields of application for high-resolution spectrometry may be opened

  6. Neutron spectrometry with Bonner spheres for area monitoring in particle accelerators

    International Nuclear Information System (INIS)

    Bedogni, R.

    2011-01-01

    Selecting the instruments to determine the operational quantities in the neutron fields produced by particle accelerators involves a combination of aspects, which is peculiar to these environments: the energy distribution of the neutron field, the continuous or pulsed time structure of the beam, the presence of other radiations to which the neutron instruments could have significant response and the large variability in the dose rate, which can be observed when moving from areas near the beam line to free-access areas. The use of spectrometric techniques in support of traditional instruments is highly recommended to improve the accuracy of dosimetric evaluations. The multi-sphere or Bonner Sphere Spectrometer (BSS) is certainly the most used device, due to characteristics such as the wide energy range, large variety of active and passive detectors suited for different workplaces, good photon discrimination and the simple signal management. Disadvantages are the poor energy resolution, weight and need to sequentially irradiate the spheres, leading to usually long measurement sessions. Moreover, complex unfolding analyses are needed to obtain the neutron spectra. This work is an overview of the BSS for area monitoring in particle accelerators. (authors)

  7. Beta strength distributions in neutron-deficient Kr and Sr isotopes using a total absorption spectrometer

    CERN Document Server

    Maréchal, F

    2003-01-01

    Far from the line of stability, beta -decay studies are often a primary source of information on nuclear structure. The measured beta -strength distribution for a given decay can be used to verify the accuracy of our theoretical description of the parent nucleus ground state and the states populated in the daughter nucleus. Total absorption spectrometers based on large NaI crystals are well suited tools to determine the beta -strength distribution over the whole Q /sub EC/ decay window. The newly built spectrometer TAgS, dedicated to such studies, is presented and its performances and possibilities are discussed in the light of experiments performed at the ISOLDE /CERN mass separator. The resulting information on ground state deformations for the /sup 74/Kr and /sup 76/Sr isotopes are discussed. (22 refs).

  8. Characterization of extended range Bonner Sphere Spectrometers in the CERF high-energy broad neutron field at CERN

    Science.gov (United States)

    Agosteo, S.; Bedogni, R.; Caresana, M.; Charitonidis, N.; Chiti, M.; Esposito, A.; Ferrarini, M.; Severino, C.; Silari, M.

    2012-12-01

    The accurate determination of the ambient dose equivalent in the mixed neutron-photon fields encountered around high-energy particle accelerators still represents a challenging task. The main complexity arises from the extreme variability of the neutron energy, which spans over 10 orders of magnitude or more. Operational survey instruments, which response function attempts to mimic the fluence-to-ambient dose equivalent conversion coefficient up to GeV neutrons, are available on the market, but their response is not fully reliable over the entire energy range. Extended range rem counters (ERRC) do not require the exact knowledge of the energy distribution of the neutron field and the calibration can be done with a source spectrum. If the actual neutron field has an energy distribution different from the calibration spectrum, the measurement is affected by an added uncertainty related to the partial overlap of the fluence-to-ambient dose equivalent conversion curve and the response function. For this reason their operational use should always be preceded by an "in-field" calibration, i.e. a calibration made against a reference instrument exposed in the same field where the survey-meter will be employed. In practice the extended-range Bonner Sphere Spectrometer (ERBSS) is the only device which can serve as reference instrument in these fields, because of its wide energy range and the possibility to assess the neutron fluence and the ambient dose equivalent (H*(10)) values with the appropriate accuracy. Nevertheless, the experience gained by a number of experimental groups suggests that mandatory conditions for obtaining accurate results in workplaces are: (1) the use of a well-established response matrix, thus implying validation campaigns in reference monochromatic neutrons fields, (2) the expert and critical use of suitable unfolding codes, and (3) the performance test of the whole system (experimental set-up, elaboration and unfolding procedures) in a well

  9. Coherent backscattering effect in spectra of icy satellites and its modeling using multi-sphere T-matrix (MSTM) code for layers of particles

    Science.gov (United States)

    Pitman, Karly M.; Kolokolova, Ludmilla; Verbiscer, Anne J.; Mackowski, Daniel W.; Joseph, Emily C. S.

    2017-12-01

    The coherent backscattering effect (CBE), the constructive interference of light scattering in particulate surfaces (e.g., regolith), manifests as a non-linear increase in reflectance, or opposition surge, and a narrow negative polarization feature at small solar phase angles. Due to a strong dependence of the amplitude and angular width of this opposition surge on the absorptive characteristics of the surface material, CBE also produces phase-angle-dependent variations in the near-infrared spectra. In this paper we present a survey of such variations in the spectra of icy satellites of Saturn obtained by the Cassini spacecraft's Visual and Infrared Mapping Spectrometer (VIMS) and in the ground-based spectra of Oberon, a satellite of Uranus, obtained with TripleSpec, a cross-dispersed near-infrared spectrometer on the Astrophysical Research Consortium 3.5-m telescope located at the Apache Point Observatory near Sunspot, New Mexico. The paper also presents computer modeling of the saturnian satellite spectra and their phase-angle variations using the most recent version of the Multi-Sphere T-Matrix (MSTM) code developed to simulate light scattering by layers of randomly distributed spherical particles. The modeling allowed us not only to reproduce the observed effects but also to estimate characteristics of the icy particles that cover the surfaces of Rhea, Dione, and Tethys.

  10. Simulations and measurements of the performance of a channeled neutron guide for a time-of-flight spectrometer at the NIST Center for Neutron Research

    International Nuclear Information System (INIS)

    Cook, Jeremy C.; Copley, John R.D.

    2004-01-01

    We describe the identification and analysis of the principal sources of intensity loss within the five-channeled neutron guide tube that was originally installed in the chopper section of the Disk Chopper Spectrometer at the National Institute of Standards and Technology Center for Neutron Research. (The purpose of the five channels was to optimize intensity and resolution in three different modes of operation known as ''resolution modes.'') By combining measurements, Monte Carlo simulations, and analytical calculations, we have developed a model that successfully explains performance losses in the original guide. We have used this model to quantify expected returns in performance using a replacement guide in which the principal contributions to the intensity loss are reduced to the minimum achievable with current technology. We have also estimated the intensity gains that would be achieved if one of the limited number of options were adopted for modifying the original guide in a manner likely to produce such gains. We describe factors that affect the performance of the original guide and compare the measured and predicted performance of the modified guide against predictions for the optimal replacement guide. The simulations indicate that the modified guide (which has three channels rather than the original five) produces greater intensity gains over a large incident wavelength band for the low and medium resolution modes, whereas a high quality replacement guide greatly improves performance in the high resolution mode of operation. Because the low and medium resolution modes are most heavily demanded, we opted to modify the guide rather than replace it. We describe the nature of this modification and present intensity measurements that meet or exceed predictions in all resolution modes with no detectable change in the energy resolution nor increase in the instrumental background

  11. The orphee versatile low-cost multiprocessor system for data acquisition and control of neutron spectrometers

    International Nuclear Information System (INIS)

    Koskas, G.

    1988-01-01

    This paper describes the new data acquisition and control system of the neutron scattering instruments at the ORPHEE research reactor. The existing system has undergone a complete change: the original CAMAC system and minicomputer controlling each experiment have given way to commercial CPU boards and microcomputers like the IBM-PC. The communication links between these two components are the IEEE 488 or RS232 standards. Emphasis is placed on the flexibility and modular nature of such a system which makes a maximum use of commercial products thus guaranteeing reliability and ease of use. A study of the requirements and evolutions, technical as well as philosophical, is detailed to demonstrate the motivation of the choice of the system architecture. A survey of the various hardware and software achievements and finally an overview of future improvements is given

  12. The Text of the Agreement for conducting under the Auspices of the Agency. A Regional Joint Training and Research Programme using a Neutron Crystal Spectrometer

    International Nuclear Information System (INIS)

    1964-01-01

    On 11 June 1964 the Board of Governors approved an Agreement for conducting, under the auspices of the Agency, a regional joint training and research programme using a neutron crystal spectrometer. The text of that Agreement is reproduced in this document for the information of all Members. The entry into force of the Agreement in accordance with Section 17 thereof, as well as later acceptances by additional Governments, will be notified to Members in addenda to this document

  13. Improvements in apparatus and procedures for using an organic liquid scintillator as a fast-neutron spectrometer for radiation protection applications

    Energy Technology Data Exchange (ETDEWEB)

    Thorngate, J.H.

    1987-05-15

    For use in radiation protection measurements, a neutron spectrometer must have a wide energy range, good sensitivity, medium resolution, and ease of taking and reducing data. No single spectrometer meets all of these requirements. Several experiments aimed at improving and characterizing the detector response to gamma rays and neutrons were conducted. A light pipe (25 mm) was needed between the scintillator cell and the photomultiplier tube to achieve the best resolution. The light output of the scintillator as a function of gamma-ray energy was measured. Three experiments were conducted to determine the light output as a function of neutron energy. Monte Carlo calculations were made to evaluate the effects of multiple neutron scattering and edge effects in the detector. The electronic systems associated with the detector were improved with a transistorized circuit providing the bias voltage for the photomultiplier tube dynodes. This circuit was needed to obtain pulse-height linearity over the wide range of signal sizes. A special live-time clock was built to compensate for the large amount of dead time generated by the pulse-shape discrimination circuit we chose to use. 64 refs., 58 figs., 9 tabs.

  14. Determination of the neutron and photon dose equivalent at work places in nuclear facilities of Sweden. An SSI - EURADOS comparison exercise. Part 2: Evaluation

    International Nuclear Information System (INIS)

    Bartlett, D.; Drake, P.; Lindborg, L.; Klein, H.; Schmitz, Th.; Tichy, M.

    1999-06-01

    Various mixed neutron-photon fields at workplaces in the containment of pressurised water reactors and in the vicinity of transport containers with spent fuel elements were investigated with spectrometers and dosimeters. The spectral neutron fluences evaluated from measurements with multisphere systems were recommended to be used for the calculation of dosimetric reference values for comparison with the readings of the dosemeters applied simultaneously. It turned out that most of the moderator based area dosemeters overestimated, while the TEPC systems generally underestimated the ambient dose equivalent (DE) values of the rather soft neutron fields encountered at these workplaces. The discrepancies can, however, be explained on the basis of energy dependent responses of the instruments used. The ambient DE values obtained with recently developed area dosemeters based on superheated drop detectors and with track etch based personal dosemeters on phantoms, however, were in satisfying agreement with the reference data. Sets of personal dosemeters simultaneously irradiated on a phantom allowed to roughly estimate the directional dependence of the neutron fluence. Hence, personal and limiting dose equivalent quantities could also be calculated. The personal and ambient DE values were always conservative estimates of the limiting quantities. Unexpectedly, discrepancies were observed for photon DE data measured with GM counters and TEPC systems. The up to 50 % higher readings of the GM counters may be explained by a considerable contribution of high energy photons to the total photon dose equivalent, but photon spectrometry is necessary for final clarification

  15. Determination of the neutron and photon dose equivalent at work places in nuclear facilities of Sweden. An SSI - EURADOS comparison exercise. Part 2: Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D. [National Radiological Protection Board, Chilton (United Kingdom); Drake, P. [Vattenfall AB, Vaeroebacka (Sweden); Lindborg, L. [Swedish Radiation Protection Inst., Stockholm (Sweden); Klein, H. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Schmitz, Th. [Forschungszentrum Juelich GmbH, Juelich (Germany); Tichy, M

    1999-06-01

    Various mixed neutron-photon fields at workplaces in the containment of pressurised water reactors and in the vicinity of transport containers with spent fuel elements were investigated with spectrometers and dosimeters. The spectral neutron fluences evaluated from measurements with multisphere systems were recommended to be used for the calculation of dosimetric reference values for comparison with the readings of the dosemeters applied simultaneously. It turned out that most of the moderator based area dosemeters overestimated, while the TEPC systems generally underestimated the ambient dose equivalent (DE) values of the rather soft neutron fields encountered at these workplaces. The discrepancies can, however, be explained on the basis of energy dependent responses of the instruments used. The ambient DE values obtained with recently developed area dosemeters based on superheated drop detectors and with track etch based personal dosemeters on phantoms, however, were in satisfying agreement with the reference data. Sets of personal dosemeters simultaneously irradiated on a phantom allowed to roughly estimate the directional dependence of the neutron fluence. Hence, personal and limiting dose equivalent quantities could also be calculated. The personal and ambient DE values were always conservative estimates of the limiting quantities. Unexpectedly, discrepancies were observed for photon DE data measured with GM counters and TEPC systems. The up to 50 % higher readings of the GM counters may be explained by a considerable contribution of high energy photons to the total photon dose equivalent, but photon spectrometry is necessary for final clarification.

  16. Experimental test of a newly developed single-moderator, multi-detector, directional neutron spectrometer in reference monochromatic fields from 144 keV to 16.5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Gómez-Ros, J.M. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Pola, A.; Bortot, D. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Gentile, A. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Introini, M.V. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Buonomo, B. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Mazzitelli, M. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Sacco, D. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); INAIL – DPIA, Via di Fontana Candida n.1, 00040 Monteporzio Catone (Italy)

    2015-05-11

    A new directional neutron spectrometer called CYSP (CYlindrical SPectrometer) was developed within the NESCOFI@BTF (2011–2013) collaboration. The device, composed by seven active thermal neutron detectors located along the axis of a cylindrical moderator, was designed to simultaneously respond from the thermal domain up to hundreds of MeV neutrons. The new spectrometer condenses the performance of the Bonner Sphere Spectrometer in a single moderator; thus requiring only one exposure to determine the whole spectrum. The CYSP response matrix, determined with MCNP, has been experimentally evaluated with monochromatic reference neutron fields from 144 keV to 16.5 MeV, plus a {sup 252}Cf source, available at NPL (Teddington, UK). The results of the experiment confirmed the correctness of the response matrix within an overall uncertainty of ±2.5%. The new active spectrometer CYSP offers an innovative option for real-time monitoring of directional neutron fields as those produced in neutron beam-lines.

  17. Experimental assessment of the performance of a proposed lead slowing-down spectrometer at WNR/PSR [Weapons Neutron Research/Proton Storage Ring

    International Nuclear Information System (INIS)

    Moore, M.S.; Koehler, P.E.; Michaudon, A.; Schelberg, A.; Danon, Y.; Block, R.C.; Slovacek, R.E.; Hoff, R.W.; Lougheed, R.W.

    1990-01-01

    In November 1989, we carried out a measurement of the fission cross section of 247 Cm, 250 Cf, and 254 Es on the Rensselaer Intense Neutron Source (RINS) at Rensselaer Polytechnic Institute (RPI). In July 1990, we carried out a second measurement, using the same fission chamber and electronics, in beam geometry at the Los Alamos Neutron Scattering Center (LANSCE) facility. Using the relative count rates observed in the two experiments, and the flux-enhancement factors determined by the RPI group for a lead slowing-down spectrometer compared to beam geometry, we can assess the performance of a spectrometer similar to RINS, driven by the Proton Storage Ring (PSR) at the Los Alamos National Laboratory. With such a spectrometer, we find that is is feasible to make measurements with samples of 1 ng for fission 1 μg for capture, and of isotopes with half-lives of tens of minutes. It is important to note that, while a significant amount of information can be obtained from the low resolution RINS measurement, a definitive determination of average properties, including the level density, requires that the resonance structure be resolved. 12 refs., 5 figs., 3 tabs

  18. Experimental assessment of the performance of a proposed lead slowing-down spectrometer at WNR/PSR (Weapons Neutron Research/Proton Storage Ring)

    Energy Technology Data Exchange (ETDEWEB)

    Moore, M.S.; Koehler, P.E.; Michaudon, A.; Schelberg, A. (Los Alamos National Lab., NM (USA)); Danon, Y.; Block, R.C.; Slovacek, R.E. (Rensselaer Polytechnic Inst., Troy, NY (USA)); Hoff, R.W.; Lougheed, R.W. (Lawrence Livermore National Lab., CA (USA))

    1990-01-01

    In November 1989, we carried out a measurement of the fission cross section of {sup 247}Cm, {sup 250}Cf, and {sup 254}Es on the Rensselaer Intense Neutron Source (RINS) at Rensselaer Polytechnic Institute (RPI). In July 1990, we carried out a second measurement, using the same fission chamber and electronics, in beam geometry at the Los Alamos Neutron Scattering Center (LANSCE) facility. Using the relative count rates observed in the two experiments, and the flux-enhancement factors determined by the RPI group for a lead slowing-down spectrometer compared to beam geometry, we can assess the performance of a spectrometer similar to RINS, driven by the Proton Storage Ring (PSR) at the Los Alamos National Laboratory. With such a spectrometer, we find that is is feasible to make measurements with samples of 1 ng for fission 1 {mu}g for capture, and of isotopes with half-lives of tens of minutes. It is important to note that, while a significant amount of information can be obtained from the low resolution RINS measurement, a definitive determination of average properties, including the level density, requires that the resonance structure be resolved. 12 refs., 5 figs., 3 tabs.

  19. Study of neutron spectra using sources of {sup 241}AmBE and {sup 238}PuBe moderated in water; Estudo de espectros neutrônicos com fontes de {sup 241}AmBE e {sup 238}PuBe moderados em água

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Angela S.; Silva, Fellipe S.; Patrão, Karla C.S.; Fonseca, Evaldo S. da; Pereira, Walsan W., E-mail: angela.souzagon@gmail.com [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Metrologia de Neutrons; Fundação Técnico-Educacional Souza Marques (FTESM), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    Recent works demonstrate the increasing importance of characterizing the spectrum of neutron sources for various energies. The main objective of this study is to make the understanding of the interaction of neutrons as close as possible to the reality in which the workers act, thus allowing to act directly in the area of radioprotection. In this way, neutron fluence determination of the {sup 241}AmBe source of 0.6 TBq (16 Ci) and {sup 238} PuBe 1.8 TBq (50 Ci) free in the air and inserted in aluminium spheres of 16 cm and 20.5 cm filled with distilled water. The measurements were carried out in the low scattering laboratory of the Laboratory of Neutron Metrology, in order to obtain a more realistic spectrum. Spectrum determination is based on measurement using the Bonner multisphere spectrometer containing readings with the ball-free detector and covered with polyethylene spheres having diameters of: 5,08 cm (2″), 7,62 cm (3″), 12,70 cm (5″), 20,32 cm (8″), 25,40 cm (10″) e 30,48 cm (12″). The aim is to characterize a new moderate spectrum in water using the sources of {sup 238}PuBe and {sup 241}AmBe that may represent realistic fields in the radioprotection area useful for testing, calibration and irradiation of individual and area monitors for neutrons.

  20. Neutron scattering. Experiment manuals

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2010-07-01

    The following topics are dealt with: The thermal triple axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, neutron polarization analysis with tht time-of-flight spectrometer DNS, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering with the KWS-1 and KWS-2 diffractometers, the very-small-angle neutron scattering diffractrometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  1. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2010-01-01

    The following topics are dealt with: The thermal triple axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, neutron polarization analysis with tht time-of-flight spectrometer DNS, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering with the KWS-1 and KWS-2 diffractometers, the very-small-angle neutron scattering diffractrometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  2. Measurements of double differential charged particle emission cross sections and development of a wide range charged particles spectrometer for ten`s MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Nauchi, Yasushi; Baba, Mamoru; Kiyosumi, Takehide [Tohoku Univ., Sendai (Japan). Faculty of Engineering] [and others

    1997-03-01

    We measured (n,xp), (n,xd) cross sections of C and Al for En=64.3 MeV neutrons at the {sup 7}Li(p,n) neutron sources facility at TIARA (Takasaki Establishment, JAERI) by using a conventional SSD-NaI telescope placed in the air. They show characteristic energy and angular dependence in high energy regions. In order to extend the measurements to low energy protons and {alpha} particles, a new spectrometer consisting of low pressure gas counters and BaF{sub 2} scintillators is now under development. A low threshold for low energy {alpha} particles will be achieved by using the gas counters. The particle identification over a wide energy range will be achieved by combining the {Delta}E-E method for low energy particles with the pulse shape discrimination (PSD) method of BaF{sub 2} for high energy particles. (author)

  3. Optimizing a neutron-beam focusing device for the direct geometry time-of-flight spectrometer TOFTOF at the FRM II reactor source

    DEFF Research Database (Denmark)

    Rasmussen, N. G.; Simeoni, G. G.; Lefmann, K.

    2016-01-01

    (adjustable supermirror curvature) and the compact size (only 0.5 m long). We have simulated the neutron transport across the entire guide system. We present a detailed computer characterization of the existing device, along with the study of the factors mostly influencing the future improvement. We have......, and the ability of a variable curvature to keep the focal point at the sample position. Our simulations are in excellent agreement with theoretical predictions and the experimentally measured beam profile. With respect to the possibility of a further upgrade, we find that supermirror coatings with m-values higher...... than 3.5 would have only marginal influence on the optimal behaviour, whereas comparable spectrometers could take advantage of longer focusing segments, with particular impact for the thermal region of the neutron spectrum....

  4. Optimisation of a collimator array for a multi-detector time-of-flight spectrometer for fast neutrons

    International Nuclear Information System (INIS)

    Schlegel-Bickmann, D.

    1979-01-01

    A Monte Carlo program has been developed which calculates the neutron background due to the interaction between incident neutrons and the collimator fan near the detector in dependence of geometry and material parameters. The position of the neutron source with regard to the collimators may be chosen at random. The program is also suitable for other three-dimensional transport problems of fast neutrons in the energy range between 0.5 and 20 MeV. The modular structure makes it easy to adapt it to highly specific problems. (orig.) 891 HP 892 MB [de

  5. First records of thermal neutrons with the spectrometer for time of flight (TOF) in the RP-10 Nuclear Reactor

    International Nuclear Information System (INIS)

    Munive, M.; Baltuano, O; Soto, C; Ravello, Y

    2002-01-01

    To obtain the first spectrum of an emergent beam of neutrons of a nuclear reactor is the main parameter of the characterization in the use of this reactor; one of ways to get this spectrum is for the technique of time of flight, TOF, which registers the time that a neutron need to cover a certain distance, associating this time then to the kinetic energy of the neutron. The kinetic study of the beam of neutrons is carried out on neutron pulses that are generated by a revolving choke called Chopper; and the analysis in the time of the detected pulses is carried out for a system MCS. Using this technique it is achieved the record of the spectra in energy, or in wavelength , of the irradiation facilities No 2 and 4, and of the exit N o 5 of the thermal column of the Nuclear Reactor RP-10 of the Nuclear Center Oscar de la Guerra RACSO, Peru (au)

  6. Structural studies of hard and soft matter using a 36-meter small-angle neutron scattering BATAN spectrometer (SMARTer) in Serpong, Indonesia

    International Nuclear Information System (INIS)

    Putra, Edy Giri Rachman; Patriati Arum

    2010-01-01

    A 36 meter small-angle neutron scattering (SANS) spectrometer in Serpong, Indonesia is the one of the largest SANS spectrometers nowadays in the Asia-Oceania region. The spectrometer has been revitalized, developed, and improved both on the instrumentation and experimental method, and then utilized for inter-laboratory comparison and basic research purposes. Liquid, gel, powder, solid-state thin film, metal plate and amorphous samples have been performed for structural and self-assembly mechanism studies. The morphological changes of micelles in micellar solutions were the most interesting research works in the last several years. Detailed structure studies on core-shell micelle were succeeded by applying a contrast variation method, i.e. H 2 O/D 2 O mixture solution. Diluted nanoparticle and ordered systems from solution, powder and solid-state samples which correspond to form and structure factors have been investigated. The fractals structures of disordered system from aggregation of ferrofluids nanoparticles and aerogels have been accomplished directly through a 'power-law' scattering approximation. Magnetic structure from metal-alloys, showing anisotropic magnetic scattering structure properties up to 1 tesla of external magnetic field was also accomplished confirming the crystalline and magnetic domain sizes. Recently, most of experiments on biological materials were performed for investigating the structure and dynamics of protein and virus in solutions. (author)

  7. Measurement of the neutron fields produced by a 62 MeV proton beam on a PMMA phantom using extended range Bonner sphere spectrometers

    Science.gov (United States)

    Amgarou, K.; Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; Carinci, G.; Russo, S.

    2011-10-01

    The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments. In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to Emeasurements at hadron therapy facilities, an ERBSS experiment was carried out at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of INFN—LNS (Laboratori Nazionali del Sud), where a proton beam routinely used for ophthalmic cancer treatments is available. The 62 MeV beam was directed towards a PMMA phantom, simulating the patient, and two neutron measurement points were established at 0° and 90° with respect to the beam-line. Here the ERBSS of UAB (Universidad Autónoma de Barcelona— Grup de Física de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Frascati) were exposed to characterize the "forward" and "sideward" proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and independently established and calibrated, is important for guaranteeing the robustness of the measured spectra and estimating their overall uncertainties.

  8. Development and Analysis of Volume Multi-Sphere Method Model Generation using Electric Field Fitting

    Science.gov (United States)

    Ingram, G. J.

    Electrostatic modeling of spacecraft has wide-reaching applications such as detumbling space debris in the Geosynchronous Earth Orbit regime before docking, servicing and tugging space debris to graveyard orbits, and Lorentz augmented orbits. The viability of electrostatic actuation control applications relies on faster-than-realtime characterization of the electrostatic interaction. The Volume Multi-Sphere Method (VMSM) seeks the optimal placement and radii of a small number of equipotential spheres to accurately model the electrostatic force and torque on a conducting space object. Current VMSM models tuned using force and torque comparisons with commercially available finite element software are subject to the modeled probe size and numerical errors of the software. This work first investigates fitting of VMSM models to Surface-MSM (SMSM) generated electrical field data, removing modeling dependence on probe geometry while significantly increasing performance and speed. A proposed electric field matching cost function is compared to a force and torque cost function, the inclusion of a self-capacitance constraint is explored and 4 degree-of-freedom VMSM models generated using electric field matching are investigated. The resulting E-field based VMSM development framework is illustrated on a box-shaped hub with a single solar panel, and convergence properties of select models are qualitatively analyzed. Despite the complex non-symmetric spacecraft geometry, elegantly simple 2-sphere VMSM solutions provide force and torque fits within a few percent.

  9. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2012-01-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot single-crystal diffractometer HEiDi for structure analysis with neutrons, the backscattering spectrometer SPHERES, the neutron polarization analyzer DNS, the neutron spin-echo spectrometer J-NSE, the small-angle neutron diffractometers KWS-1/-2, the very-small-angle neutron diffractometer with focusing mirror KWS-3, the resonance spin-echo spectrometer RESEDA, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  10. Measuring the energies and multiplicities of prompt gamma-ray emissions from neutron-induced fission of $^{235}$U using the STEFF spectrometer

    CERN Document Server

    AUTHOR|(CDS)2093036; Smith, Alastair Gavin; Wright, Tobias James

    Following a NEA high priority nuclear data request, an experimental campaign to measure the prompt $\\gamma$-ray emissions from $^{235}$U has been performed. This has used the STEFF spectrometer at the new Experimental Area 2 (EAR2) within the neutron timeof-flight facility (n_TOF), a white neutron source facility at CERN with energies from thermal to approximately 1 GeV. Prior to the experimental campaign, STEFF has been optimised for the environment of EAR2. The experimental hall features a high background $\\gamma$-ray rate, due to the nature of the spallation neutron source. Thus an investigation into reduction of the background $\\gamma$-ray rate, encountered by the NaI(Tl) detector array of STEFF, has been carried out. This has been via simulations using the simulation package FLUKA. Various materials and shielding geometries have been investigated but the effects determined to be insufficient in reducing the background rate by a meaningful amount. The NaI(Tl) detectors have been modified to improve their ...

  11. In-beam test of the Boron-10 Multi-Grid neutron detector at the IN6 time-of-flight spectrometer at the ILL

    Science.gov (United States)

    Birch, J.; Buffet, J.-C.; Clergeau, J.-F.; Correa, J.; van Esch, P.; Ferraton, M.; Guerard, B.; Halbwachs, J.; Hall-Wilton, R.; Hultman, L.; Höglund, C.; Khaplanov, A.; Koza, M.; Piscitelli, F.; Zbiri, M.

    2014-07-01

    A neutron detector concept based on solid layers of boron carbide enriched in 10B has been in development for the last few years as an alternative for 3He by collaboration between the ILL, ESS and Linköping University. This Multi-Grid detector uses layers of aluminum substrates coated with 10B4C on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the 3He detectors of IN6 at ILL. The 10B detector has an active area of 32 x 48cm2. It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional 3He detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background.

  12. Research with the high resolution spectrometer at LAMPF. [Differential cross sections, analyzing power, neutron density, 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-31

    Differential cross sections, analyzing power, neutron density parameters, and the differences between neutron and proton rms radii are studied for the reactions of 800-MeV polarized protons elastically scattered from /sup 12/,/sup 13/C, /sup 40/,/sup 42/,/sup 44/,/sup 48/Ca, /sup 46/,/sup 48/,/sup 50/Ti, /sup 58/,/sup 64/Ni, /sup 116/,/sup 124/Sn, /sup 54/Fe, and /sup 208/Pb. 18 references. (JFP)

  13. Measurements of neutron spectrum from uranium converter

    International Nuclear Information System (INIS)

    Ninkovic, M.; Sotic, O.; Marinkovic, S.

    1978-01-01

    The procedure for determination of energetic distribution of neutrons by the multisphere technique is given. The theoretical basis and features of the method are explained. The spectral distribution of neutrons emerging from the neutron converter constructed at the bare reactor assembly RB, has been determined applying the existing computer programme and literature data for the energetic dependence functions of spheres of various diameters. The obtained spectral distribution has a specific maximum in the domain of fast neutrons, justifying thus the reacton for the construction of the converter. The neutron spectrum data obtained and given in this report are very important for the use of the converter in neutron dosimetry and radiation protection, as well as in the radiobiology, shielding, reactor physics etc. (author)

  14. The electron antineutrino angular correlation coefficient a in free neutron decay. Testing the standard model with the aSPECT-spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Borg, Michael

    2011-02-04

    The {beta}-decay of free neutrons is a strongly over-determined process in the Standard Model (SM) of Particle Physics and is described by a multitude of observables. Some of those observables are sensitive to physics beyond the SM. For example, the correlation coefficients of the involved particles belong to them. The spectrometer aSPECT was designed to measure precisely the shape of the proton energy spectrum and to extract from it the electron anti-neutrino angular correlation coefficient a. A first test period (2005/2006) showed the ''proof-of-principles''. The limiting influence of uncontrollable background conditions in the spectrometer made it impossible to extract a reliable value for the coefficient a (published in 2008). A second measurement cycle (2007/2008) aimed to under-run the relative accuracy of previous experiments ({delta}a)/(a)=5%. I performed the analysis of the data taken there which is the emphasis of this doctoral thesis. A central point are background studies. The systematic impact of background on a was reduced to ({delta}a{sup (syst.)})/(a)=0.61 %. The statistical accuracy of the analyzed measurements is ({delta}a{sup (stat.)})/(a){approx}1.4 %. Besides, saturation effects of the detector electronics were investigated which were initially observed. These turned out not to be correctable on a sufficient level. An applicable idea how to avoid the saturation effects is discussed in the last chapter. (orig.)

  15. The electron antineutrino angular correlation coefficient a in free neutron decay. Testing the standard model with the aSPECT-spectrometer

    International Nuclear Information System (INIS)

    Borg, Michael

    2011-01-01

    The β-decay of free neutrons is a strongly over-determined process in the Standard Model (SM) of Particle Physics and is described by a multitude of observables. Some of those observables are sensitive to physics beyond the SM. For example, the correlation coefficients of the involved particles belong to them. The spectrometer aSPECT was designed to measure precisely the shape of the proton energy spectrum and to extract from it the electron anti-neutrino angular correlation coefficient a. A first test period (2005/2006) showed the ''proof-of-principles''. The limiting influence of uncontrollable background conditions in the spectrometer made it impossible to extract a reliable value for the coefficient a (published in 2008). A second measurement cycle (2007/2008) aimed to under-run the relative accuracy of previous experiments (δa)/(a)=5%. I performed the analysis of the data taken there which is the emphasis of this doctoral thesis. A central point are background studies. The systematic impact of background on a was reduced to (δa (syst.) )/(a)=0.61 %. The statistical accuracy of the analyzed measurements is (δa (stat.) )/(a)∼1.4 %. Besides, saturation effects of the detector electronics were investigated which were initially observed. These turned out not to be correctable on a sufficient level. An applicable idea how to avoid the saturation effects is discussed in the last chapter. (orig.)

  16. Neutron scattering. Experiment manuals

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2014-01-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot-single-crystal diffractometer HEiDi, the three-axis spectrometer PANDA, the backscattering spectrometer SPHERES, the DNS neutron-polarization analysis, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering at KWS-1 and KWS-2, a very-small-angle neutron scattering diffractometer with focusing mirror, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  17. Neutron scattering. Experiment manuals

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2014-07-01

    The following topics are dealt with: The thermal triple-axis spectrometer PUMA, the high-resolution powder diffractometer SPODI, the hot-single-crystal diffractometer HEiDi, the three-axis spectrometer PANDA, the backscattering spectrometer SPHERES, the DNS neutron-polarization analysis, the neutron spin-echo spectrometer J-NSE, small-angle neutron scattering at KWS-1 and KWS-2, a very-small-angle neutron scattering diffractometer with focusing mirror, the reflectometer TREFF, the time-of-flight spectrometer TOFTOF. (HSI)

  18. TRISP: Three axes spin echo spectrometer

    Directory of Open Access Journals (Sweden)

    Thomas Keller

    2015-12-01

    Full Text Available TRISP, operated by the Max-Planck-Institute for Solid State Research, is a high-resolution neutron spectrometer combining the three axes and neutron resonance spin echo (NRSE techniques.

  19. The PERC spectrometer for the study of the neutron beta decay; Das Spektrometer PERC zur Untersuchung des Neutron-Beta-Zerfalls

    Energy Technology Data Exchange (ETDEWEB)

    Ziener, Carmen Regina

    2014-12-17

    The precise investigation of the weak interaction in free neutron decay allows to intensively test the Standard Modell and find physics beyond. In this work, the magnet system of the bright and clean proton- and electron source PERC (Proton-Electron-Radiation-Channel) was developed. It will be installed in 2016 at the research reactor FRM II. Due to improvements in systematics and statistics in comparison to its predecessor PERKEO III, observables of free neutron decay can be determined with the worldwide best precision of 10{sup -4}. In this thesis, the technical and physical properties of the magnet system will be discussed. As a major part of this work, an efficient geometry for a back-scatter detector was developed. Undetected back-scatter events for electrons would disturb the spectra in the order of 10{sup -3} for a plastic scintillator. Here, the geometry will be introduced and back-scatter events will be analyzed by simulations. For the experimental part of the present work, titanium sublimation pumps and ion getter pumps were constructed and tested. As components of the over 12 m long ultra-high vacuum system of PERC they can effectively reduce the pressure to the order of 10{sup -9} mbar over the complete length. Therefore collisions of electrons and protons with gas particles will be strongly suppressed.

  20. Direct mass and lifetime measurements of neutron-rich nuclei up to A∼100 using the TOFI spectrometer at LAMPF

    International Nuclear Information System (INIS)

    Lind, V.G.

    1993-01-01

    This project was directed toward the study of neutron-rich nuclei using the experimental facilities at LAMPF, which is a part of LANL. The principal results of the investigation include the discovery of many new isotopes along with a measurement of their masses and in particular those nuclides in the Z = 7--19 and 14 --26 regions of the chart of the nuclides.Thirty-four new nuclides were detected and studied with their masses being measured with relatively high accuracy, and an additional twenty-six that were previously known and measured were remeasured to an improved accuracy. Besides providing new information about the mass surface in new and extended redons of the chart of the nuclides, this investigation enabled properties and previously unknown structure of some of the nuclei to be determined such as nuclear deformation among some of the nuclides. Also a study of the neutron pairing gaps and the proton pairing gaps among these nuclides was made. Other developments also achieved included instrument (TOFI) improvements and upgrades and theoretical investigations into the masses of the hadrons

  1. A powerful modular versatile and low cost multiprocessor system for data acquisition and control of neutron spectrometers

    International Nuclear Information System (INIS)

    Koskas, G.

    1987-04-01

    This paper describes the new data acquisition and control systems of the neutron scattering instruments at the ORPHEE research reactor. The existing system has undergone a complete change: the original CAMAC system and minicomputer controlling each experiment have given way to commercial CPU boards and microcomputers like the IBM PC. The communication links between these 2 components are the IEEE 488 or RS 232 standards. Emphasis is placed on flexibility and modular nature of such a system which makes a maximum use of commercial products thus guaranteeing reliability and ease of use. A study of the requirements and evolutions, technical as well as philosophical, is detailed in order to demonstrate the motivation of the choice of the system architecture. A survey of the various hardware and software achievements and finally an overview on the future improvements is given [fr

  2. Monolithic spectrometer

    Science.gov (United States)

    Rajic, Slobodan; Egert, Charles M.; Kahl, William K.; Snyder, Jr., William B.; Evans, III, Boyd M.; Marlar, Troy A.; Cunningham, Joseph P.

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  3. Contribution to the study of 14 MeV neutron scattering by {sup 12}C using a time-of-flight spectrometer (1963); Contribution a l'etude de la diffusion des neutrons de 14 MeV par {sup 12}C, a l'aide d'un spectrometre a temps de vol (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, P. [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-15

    Experimental measurements of 14 MeV fast neutrons scattering by {sup 12}C by time-flight spectrometer, with a 1.7 n. sec over-all resolution. The excitation of the 7.65 MeV level is observed. (author) [French] Etude experimentate de la diffusion par {sup 12}C des neutrons rapides de 14 MeV a l'aide d'un spectrometre de resolution totale de 17 n/s. Observation de l'excitation du niveau 0+ de 7,65 MeV. (auteur)

  4. Comparison of multi-sphere and superquadric particle representation for modelling shearing and flow characteristics of granular assemblies

    Directory of Open Access Journals (Sweden)

    Soltanbeigi Behzad

    2017-01-01

    Full Text Available In the current study, complex-shaped particles are simulated with the Discrete Element Method (DEM using two different approaches, namely Multi-spheres (MS and Superquadrics (SQ. Both methods have been used by researchers to represent the shape of real particles. However, despite the growing popularity of utilizing MS and SQ particles in DEM simulations, few insights have been given on the comparison of the macro scale characteristics arising from the two methods. In this respect, initially the characteristics of the two shape representation methods are evaluated in a direct shear test simulation. The results suggest that controlling the sharpness of the edges for SQ particles can lead to a good agreement with the results of MS particles. This way, a set of SQ and MS particles, which are numerically calibrated in the shear tester, are obtained. Furthermore, the macro-scale responses of the numerically calibrated particles are assessed during a slow shearing scenario, which is achieved through simulating quasi-static flow of the particles from a flat-bottom silo. The results for mass discharge, flow profile and wall pressure show a good quantitative agreement. These findings suggest that the numerically calibrated MS and SQ particles in the shear tester can provide similar bulk-scale flow properties. Moreover, the results highlight that surface bumpiness for MS particles and corner sharpness for SQ particles change the characteristics of particles and play a significant role in the shear strength of the material composed of these particles.

  5. Characterization of neutron supermirror V-bender

    Energy Technology Data Exchange (ETDEWEB)

    Shin, E. J.; Seong, B. S.; Lee, J. S.; Hong, K. P.; Choi, B. H.; Lee, C. H

    2004-05-15

    Neutron supermirror is used not only for neutron guide tubes that their make it possible to transmit neutrons for long distance with low losses in intensity but for neutron benders used as a beam splitter. These devices are of main components of advanced neutron diffractometer or spectrometer with cold neutrons. In this report, the basic principles and applications of neutron guide tube and neutron supermirror as well as the performance test results of neutron V-bender were introduced. These information will be used for the development of advance cold neutron spectrometers in the future.

  6. Characterization of neutron supermirror V-bender

    International Nuclear Information System (INIS)

    Shin, E. J.; Seong, B. S.; Lee, J. S.; Hong, K. P.; Choi, B. H.; Lee, C. H.

    2004-05-01

    Neutron supermirror is used not only for neutron guide tubes that their make it possible to transmit neutrons for long distance with low losses in intensity but for neutron benders used as a beam splitter. These devices are of main components of advanced neutron diffractometer or spectrometer with cold neutrons. In this report, the basic principles and applications of neutron guide tube and neutron supermirror as well as the performance test results of neutron V-bender were introduced. These information will be used for the development of advance cold neutron spectrometers in the future

  7. Correlation spectrometer

    Science.gov (United States)

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  8. UCN gravitational spectrometer

    International Nuclear Information System (INIS)

    Kawabata, Yuji

    1988-01-01

    Concept design is carried out of two types of ultra cold neutron scallering equipment using the fall-focusing principle. One of the systems comprises a vertical gravitational spectrometer and the other includes a horizontal gravitation analyzer. A study is made of their performance and the following results are obtained. Fall-focusing type ultra cold neutron scattering equipment can achieve a high accuracy for measurement of energy and momentum. Compared with conventional neutron scattering systems, this type of equipment can use neutron very efficiently because scattered neutrons within a larger solid angle can be used. The maximum solid angle is nearly 4π and 2π for the vertical and horizontal type, respectively. Another feature is that the size of equipment can be reduced. In the present concept design, the equipment is spherical with a diameter of about 1 m, as compared with NESSIE which is 6.7 m in length and 4.85 m in height with about the same accuracy. Two horizontal analyzers and a vertical spectroscope are proposed. They are suitable for angle-dependent non-elastic scattering in the neutron velocity range of 6∼15 m/s, pure elastic scattering in the range of 4∼7 m/s, or angle-integration non-elastic scattering in the range of 4∼15 m/s. (N.K.)

  9. Neutron wave optics studied with ultracold neutrons

    International Nuclear Information System (INIS)

    Steyerl, A.

    1984-01-01

    The author discusses experiments demonstrating or utilizing the wave properties of neutrons with wavelengths of about 100 nm. In particular the 'UCN gravity diffractometer' and the gravity spectrometer NESSIE (Neutronen-Schwerkraft-Spectrometrie) are illustrated. (Auth.)

  10. Multidimensional spectrometer

    Science.gov (United States)

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  11. Extension of the calibration of an NE-213 liquid scintillator based pulse height response spectrometer up to 18 MeV neutron energy and leakage spectrum measurements on bismuth at 8 MeV and 18 MeV neutron energies

    International Nuclear Information System (INIS)

    Fenyvesi, A.; Valastyan, I.; Olah, L.; Csikai, J.; Plompen, A.; Jaime, R.; Loevestam, G.; Semkova, V.

    2011-01-01

    Monoenergetic neutrons were produced at the Van de Graaff accelerator of the EC-JRC-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium). An air-jet cooled D 2 -gas target (1.2 bar, ΔE d = 448 keV) was bombarded with E d =4976 keV deuterons to produce neutrons up to E n = 8 MeV energy via the D(d,n) 3 He reaction. Higher energy neutrons up to E n = 18 MeV were produced via the T(d,n) 4 He reaction by bombarding a TiT target with E d =1968 keV deuterons. Pulse height spectra were measured at different neutron energies from E n = 8 MeV up to E n = 18 MeV with the NE-213 liquid scintillator based Pulse Height Response Spectrometer (PHRS) of UD-IEP. The energy calibration of the PHRS system has been extended up to E n = 18 MeV. Pulse height spectra induced by gamma photons have been simulated by the GRESP7 code. Neutron induced pulse height spectra have been simulated by the NRESP7 and MCNP-POLIMI codes. Comparison of the results of measurements and simulations enables the improvement of the parameter set of the function used by us to describe the light output dependence of the resolution of the PHRS system at light outputs of L > 2 light units. Also, it has been shown that the derivation method for unfolding neutron spectra from measured pulse height spectra performs well when relative measurements are done up to E n = 18 MeV neutron energy. For matrix unfolding purposes, the NRESP7 code has to be preferred to calculate the pulse height response matrix of the PHRS system. Leakage spectra of neutrons behind bismuth slabs of different thicknesses have been measured with the PHRS system by using monoenergetic neutrons. The maximum slab thickness was d = 14 cm. Simulations of the measurements have been carried out with the MCNP-4c code. The necessary nuclear cross-sections were taken from the from the ENDF/B-VII and JEFF.3.1 data libraries. For both libraries, the agreement of measured and simulated neutron spectra is good for the 5 MeV ≤ En ≤ 18

  12. Evaluation of the ROTAX spectrometer

    International Nuclear Information System (INIS)

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  13. Mass spectrometers

    International Nuclear Information System (INIS)

    Manojlov, V.E.; Nedelin, P.N.; Lukichev, A.N.; Sapozhkov, L.K.; Turubarov, V.I.

    1980-01-01

    Mass spectrometers of different types are suggested to use for qualitative and quantitative analyses of gas. The operation principles of static and dynamic mass spectrometer are studied. In static mass spectrometers mass separation of ions is performed by changing the value of accelerating voltage in the ion source when retaining the magnetic field intensity. Such devices are stationary. The device mass is conditioned by the magnet mass. Mass separation in dynamic mass spectrometers is dependent on the degree of energy increment of ions in HF-electric fields. Radio frequency mass spectrometers are used with advantage for studying upper layers of an atmosphere and are installed on radiosondes and satellites. The main technical characteristics of the MX-1330 mass spectrometer, the basis of which is the analyzer with 180 deg deviation of an ion beam in the field of permanent magnet, are presented. The device is intended for controlling the environment and permits to analyze gases with a molecular mass up to 450 using various systems of gas filling. The error of determination of molecular substance is not greater than +-3 %; the magnetic field intensity constitutes 4.8x10 5 A/m; the supply voltage is 380/220 V; the total power is 5.0 kVA [ru

  14. The Philippine spectrometer

    International Nuclear Information System (INIS)

    Juliano, J.O.

    1965-01-01

    A notable project for international collaboration, in which participants from Indonesia, Korea, Thailand, China and the Philippines are working together, has been launched in the Philippines with Indian assistance under the aegis of the Agency. This is a regional training and research programme using a neutron crystal spectrometer, which has been established since January 1965 at the Philippine Atomic Research Centre in Diliman, Quezon City, Philippines. It is called the IPA Project after the signatories to a five year trilateral agreement, namely, the Government of India,the Republic of the Philippines, and the International Atomic Energy Agency. The programme is administered by a Joint Committee composed of one representative each of the Philippines, India and the Agency. The objective of this cooperative venture is to establish a research centre on neutron diffraction in which scientists and technicians from any Member State of IAEA in South Asia, South-East Asia and Pacific, or Far East regions could come to participate in research and training. Studies in solid state physics, such a s the structure determination of alloys and organic crystals, studies on the orientation of magnetic moments in the lattice of magnetic substances, and other problems based on elastic and inelastic scattering of neutrons are undertaken. There are a number of research reactors in this region where neutron spectrometers can be utilized and the recent establishment of this cooperative international research and training programme has been a timely one for this area of the world. Indeed, a number of other countries have shown a strong growing interest in the development of the project

  15. Chopper spectrometers at J-PARC for dynamical studies on structural science

    International Nuclear Information System (INIS)

    Itoh, Shinichi

    2008-01-01

    The construction of the following three chopper spectrometers are in progress at Japan Proton Accelerator Research Complex (J-PARC); the High Resolution Chopper Spectrometer for high resolution experiments in wide energy range, the Cold Neutron Chopper Spectrometer for high resolution experiments at low energies and the 4d Space Access Neutron Spectrometer for investigations of high-Tc superconductors. Also, the proposal for the construction of the Versatile Inelastic Neutron Spectrometer for high flux experiments in wide energy range has been approved. The performance of these chopper spectrometers are described here. (author)

  16. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  17. Study of neutron inelastic scattering spectra of ceramics Y-Ba-Cu-O by means of the direct-geometry spectrometer DIN-2 PI

    International Nuclear Information System (INIS)

    Morozov, S.I.; Grigor'ev, Yu.V.; Lushchikov, V.I.

    1994-01-01

    The inelastic slow neutron scattering of YBa 2 Cu 3 O x compounds was investigated for superconduction (x = 6.95) and non-superconduction (x = 6.4) condition. The generalized function of density of states was received. The changes in vibration spectra depending on oxygen concentration were analyzed. Comparison with results have been received earlier was carried out. High frequency vibration at energy ε ≅ 176 MeV the nature of which is not clear was found

  18. Neutron scatter camera

    Science.gov (United States)

    Mascarenhas, Nicholas; Marleau, Peter; Brennan, James S.; Krenz, Kevin D.

    2010-06-22

    An instrument that will directly image the fast fission neutrons from a special nuclear material source has been described. This instrument can improve the signal to background compared to non imaging neutron detection techniques by a factor given by ratio of the angular resolution window to 4.pi.. In addition to being a neutron imager, this instrument will also be an excellent neutron spectrometer, and will be able to differentiate between different types of neutron sources (e.g. fission, alpha-n, cosmic ray, and D-D or D-T fusion). Moreover, the instrument is able to pinpoint the source location.

  19. The Spectrometer

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  20. ODY MARS GAMMA RAY SPECTROMETER 5 AND V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The ODY MARS GAMMA RAY SPECTROMETER 5 AND data set is a table of neutron data from the NS sub-system of the Mars Odyssey Gamma-Ray Spectrometer that have been...

  1. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Groitl, Felix, E-mail: felix.groitl@psi.ch [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bartkowiak, Marek [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bergmann, Ryan M. [Division Large Research Facilities, Paul Scherrer Institut, 5232 Villigen (Switzerland); Birk, Jonas Okkels [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Physics, Technical University of Denmark (DTU), 2800 Kgs. Lyngby (Denmark); Markó, Márton [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Wigner Research Centre for Physics, Neutron Spectroscopy Department, 1525 Budapest (Hungary); Bollhalder, Alex; Graf, Dieter [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Niedermayer, Christof [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Rüegg, Christian [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Quantum Matter Physics, University of Geneva, 1211 Geneva (Switzerland); Rønnow, Henrik M. [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Niels Bohr Institute, University of Copenhagen, 2100 Copenhagen (Denmark)

    2017-06-21

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  2. MASS SPECTROMETER

    Science.gov (United States)

    White, F.A.

    1960-08-23

    A mass spectrometer is designed with a first adjustable magnetic field for resolving an ion beam into beams of selected masses, a second adjustable magnetic field for further resolving the ion beam from the first field into beams of selected masses, a thin foil disposed in the path of the beam between the first and second magnets to dissociate molecular ions incident thereon, an electrostatic field for further resolving the ion beam from the second field into beams of selected masses, and a detector disposed adjacent to the electrostatic field to receive the ion beam.

  3. Geometric positioning of the LISE (Ligne d'Ions Super Epluches) spectrometer installed at the GANIL, associated with a modular assembly for neutron detection

    International Nuclear Information System (INIS)

    Beunard, Remy

    2000-01-01

    This report presents the geometric design, methodology and proposed solutions to perform topometry and metrology works on operational and experimental elements. After a recall of the main theoretical notions of the spectrometer function, the author presents the topographic and metrological instrumentation as well as the different solutions adopted for the treatment of specific problems. After a description of the characteristics of the geometric array, the author outlines the importance of the integration of magnetic field distribution map to magnet locations. Then, the author focuses on the positioning procedure for magnetic elements by using an analytical approach. Error sources are assessed with respect to beam trajectory incidence. A smoothing procedure is used to estimate corrections to be applied to magnets. Target tilt angles are scaled to optimize the thickness crossed by the beam. The interest of a metrological control of vacuum chamber is highlighted. On the experimental level, the approach is based on the use of tachometry. A method is proposed to simplify the experimental device adjustment. Equations are processed by using the Mathcad software [fr

  4. Mass measurements on neutron-deficient nuclides at SHIPTRAP and commissioning of a cryogenic narrow-band FT-ICR mass spectrometer

    International Nuclear Information System (INIS)

    Ferrer Garcia, R.

    2007-01-01

    The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of β-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A=90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-flight ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections (σ <1 μb), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported. (orig.)

  5. Mass measurements on neutron-deficient nuclides at SHIPTRAP and commissioning of a cryogenic narrow-band FT-ICR mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer Garcia, R.

    2007-07-01

    The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of {beta}-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A=90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-flight ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections ({sigma} <1 {mu}b), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported. (orig.)

  6. Development of a 'chronotron' for time of flight fast neutron spectrometer; Realisation d'un chronotron pour spectrometre a neutrons rapides par temps de vol

    Energy Technology Data Exchange (ETDEWEB)

    Duclos, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-10-15

    A chronotron using storage circuits of a 100 channels amplitude analyser has been developed in order to measure the time of flight of fast neutrons. A time dilatation is obtained by a distribution of 20 6BN6 tubes. The width at half maximum of prompt coincidences curve is 1,6.10{sup -9} s for {beta}-{gamma} coincidences from An{sup 198} and 2.10{sup -9} s for n-{alpha} coincidences from (d, t) reaction. (author) [French] En vue de realiser un spectrometre a neutrons rapides par temps de vol, un chronotron utilisant les circuits d'enregistrement d'un selecteur d'amplitude de 100 canaux a ete construit. Une dilatation du temps est obtenue a l'aide d'une distribution de 20 lampes 6BN6. La largeur a mi-hauteur de la courbe de resolution est 1,6.10{sup -9} s pour les coincidences {beta}-{gamma} de Au{sup 198} et 2.10{sup -9} s pour les coincidences n-{alpha} de la reaction (d, t). (auteur)

  7. Status of neutron complex of INR RAS

    International Nuclear Information System (INIS)

    Grachev, M.I.; Koptelov, E.A.; Kravchuk, L.V.; Matveev, V.A.; Perekrestenko, A.D.; Sidorkin, S.F.; Stavissky, Y.Y.

    2001-01-01

    The neutron complex of INR RAS consists of two sources of neutrons, beam stop, lead slowing down spectrometer and solid state spectrometers. The description of objects and their condition, the program of planned researches, co-operation with other institutes of the Moscow Region, progress reached for last two years are introduced in the article. (author)

  8. Instrumentation for PSD-based neutron diffractometers at Dhruva ...

    Indian Academy of Sciences (India)

    positions and data is acquired simultaneously from all the PSDs. Throughput is further improved by using multiple PSDs at each position. Various instruments like the powder diffractometer, high-Q diffractometer, polarized neutron reflectometer, quasi-elastic neutron spectrometer, small-angle neutron spectrometer all use ...

  9. Fourier Transform Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The Fourier Transform Spectrometer project demonstrates the efficacy of a miniaturized spectrometer for flight applications.A spectrometer is an instrument used to...

  10. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Dasannacharya, B.A.; Goyal, P.S.

    1997-01-01

    Small angle neutron scattering (SANS) is one of the most popular neutron scattering technique both for the basic research and as a tool in the hands of applied scientist. SANS is used for studying the structure of a material on a length scale of 10 - 1000 A. SANS is a diffraction experiment that involves scattering of a monocromatic beam of neutrons in order to obtain structural information about macromolecules and heterogeneities. This paper will discuss the design of SANS spectrometers with a special emphasis on the instruments which are better suited for medium flux reactors. The design of several different types of SANS spectrometers will be given. The optimization procedures and appropriate modifications to suit the budget and the space will be discussed. As an example, the design of a SANS spectrometer at CIRUS reactor Trombay will be given. (author)

  11. Smartphone Spectrometers

    Science.gov (United States)

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  12. Smartphone Spectrometers

    Directory of Open Access Journals (Sweden)

    Andrew J.S. McGonigle

    2018-01-01

    Full Text Available Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  13. Smartphone Spectrometers.

    Science.gov (United States)

    McGonigle, Andrew J S; Wilkes, Thomas C; Pering, Tom D; Willmott, Jon R; Cook, Joseph M; Mims, Forrest M; Parisi, Alfio V

    2018-01-14

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a 'lab in a phone' capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  14. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    DEFF Research Database (Denmark)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each ot...

  15. SMARTS - a spectrometer for strain measurement in engineering materials

    CERN Document Server

    Bourke, M A M; Ustundag, E

    2002-01-01

    A new spectrometer called SMARTS (Spectrometer for Materials Research at Temperature and Stress) has been commissioned at the Los Alamos neutron science center and entered the user program in August of 2002. Its design maximizes capability and throughput for measurements of (a) residual macrostrain in engineering components and (b) in situ loading. This paper describes some aspects of the instrument. (orig.)

  16. Triple-axis spectrometer DruechaL

    International Nuclear Information System (INIS)

    Buehrer, W.; Keller, P.

    1996-01-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs

  17. Triple-axis spectrometer DruechaL

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W.; Keller, P. [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs.

  18. Neutron scattering in Indonesia. Country report

    International Nuclear Information System (INIS)

    Ikram, Abarrul

    2000-01-01

    Neutron scattering in Indonesia is still alienated due to some reasons and conditions which are discussed. The reactor and its latest operation mode are also described. The neutron beam facilities which include one diffractometer for residual stress measurement, one diffractometer for single crystal structural determination and texture measurement, one high resolution powder diffractometer, one neutron radiography facility, one triple axis spectrometer, one small angle neutron scattering spectrometer and one high resolution small angle neutron scattering spectrometer were presented briefly together with improvements of neutron intensities at some spectrometers in connection with the setting of main beam shutter position. Special attention is given for four instruments mostly related to this workshop. Their performances and problems faced in the past 9 months are presented as well as the future plan for refurbishment and development. (author)

  19. Polarized triple-axis spectrometer TASP

    Energy Technology Data Exchange (ETDEWEB)

    Boeni, P.; Keller, P. [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

  20. Polarized triple-axis spectrometer TASP

    International Nuclear Information System (INIS)

    Boeni, P.; Keller, P.

    1996-01-01

    The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs

  1. Proceedings of the international workshop on new opportunities in single crystal spectroscopy with neutrons

    International Nuclear Information System (INIS)

    Fuezi, J.; Rosta, L.

    2001-08-01

    The Conference Proceedings contains 19 papers on neutron scattering research facilities, neutron sources, scattering spectrometers, detectors, and use of neutron scattering in solid state research. 14 papers were indexed and abstracted for the INIS database. (R.P.)

  2. The GRANIT spectrometer; Le spectrometre GRANIT

    Energy Technology Data Exchange (ETDEWEB)

    Baessler, St. [University of Virginia, Charlottesville, VA 22904 (United States); Oak Ridge Nat. Lab., Oak Ridge, TN 37831 (United States); Beau, M.; Kreuz, M.; Nesvizhevsky, V.V. [ILL, 6 rue Jules Horowitz, Grenoble, F-3804(France); Kurlov, V.N. [ISSP, 2 Institutskaia, Chernogolovka, RU-142432 (Russian Federation); Pignol, G.; Protasov, K.V.; Vezzu, F. [LPSC/IN2P3-UJF-INPG, 53 rue des Martyrs, Grenoble, F-38026 (France); Voronin, A.Y. [Lebedev Institute, 53 Leninskii pr., Moscow, RU-119991 (Russian Federation)

    2010-10-15

    The existence of quantum states of matter in a gravitational field was demonstrated recently in the Institut Laue-Langevin (ILL), Grenoble, in a series of experiments with ultra cold neutrons (UCN). UCN in low quantum states is an excellent probe for fundamental physics, in particular for constraining extra short-range forces; as well as a tool in quantum optics and surface physics. The GRANIT is a follow-up project based on a second-generation spectrometer with ultra-high energy resolution, permanently installed in ILL. It will become operational in 2011. The spectrometer consists of several neutron-optics elements and UCN detectors installed on a massive granite table in an aluminium vacuum chamber with a volume of about 1.5 m{sup 3}. 3 types of detectors will be used at the first stage of the GRANIT experiment: {sup 3}He gaseous proportional counters with extremely low background, position-sensitive nuclear-track UCN detectors will be used to study the spatial distribution in quantum states, and real-time position-sensitive detectors with a resolution of a few hundred microns to measure velocity distributions of neutrons in quantum states. The key elements of the GRANIT spectrometer is a set of mirrors to shape/analyze neutron spectra and to store neutrons in quantum states

  3. RITA-type triple axis spectrometers

    International Nuclear Information System (INIS)

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  4. Peculiarities of the modern neutron spectrometry

    Indian Academy of Sciences (India)

    Abstract. Neutron spectrometry provides many branches of science and technology with the necessary data. Usually the main part of the data is supplied by powerful neutron time-of-flight spectrometers. Nevertheless there are many other very effective but simpler and cheaper neutron spectroscopy methods on accelerators, ...

  5. Peculiarities of the modern neutron spectrometry

    Indian Academy of Sciences (India)

    Neutron spectrometry provides many branches of science and technology with the necessary data. Usually the main part of the data is supplied by powerful neutron time-of-flight spectrometers. Nevertheless there are many other very effective but simpler and cheaper neutron spectroscopy methods on accelerators, suitable ...

  6. Associated Particle Tagging (APT) in Magnetic Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Baciak, James E.; Stave, Sean C.; Chichester, David; Dale, Daniel; Kim, Yujong; Harmon, Frank

    2012-10-16

    Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI). The computational study considered two principle concepts: (1) the application of a solenoidal alpha-particle spectrometer to a next-generation, large-emittance neutron generator for use in the associated particle imaging technique, and (2) the application of tagged photon beams to the detection of fissile material via active interrogation. In both cases, a magnetic spectrometer momentum-analyzes charged particles (in the neutron case, alpha particles accompanying neutron generation in the D-T reaction; in the tagged photon case, post-bremsstrahlung electrons) to define kinematic properties of the relevant neutral interrogation probe particle (i.e. neutron or photon). The main conclusions of the study can be briefly summarized as follows: Neutron generator: • For the solenoidal spectrometer concept, magnetic field strengths of order 1 Tesla or greater are required to keep the transverse size of the spectrometer smaller than 1 meter. The notional magnetic spectrometer design evaluated in this feasibility study uses a 5-T magnetic field and a borehole radius of 18 cm. • The design shows a potential for 4.5 Sr tagged neutron solid angle, a factor of 4.5 larger than achievable with current API neutron-generator designs. • The potential angular resolution for such a tagged neutron beam can be less than 0.5o for modest Si-detector position resolution (3 mm). Further improvement in angular resolution can be made by using Si-detectors with better position resolution. • The report documents several features of a notional generator design incorporating the

  7. Inelastic neutron scattering facilities at the Budapest Neutron Center

    Energy Technology Data Exchange (ETDEWEB)

    Toeroek, Gy.; Nagy, A. [Research Institute for Solid State Physics and Optics, P.O.B.49, 1525 Budapest (Hungary); Lebedev, V.T.; Gordeev, G.P. [Petersburg Nuclear Physics Institute, 188300 Gatchina (Russian Federation); Zsigmond, G. [Hahn Meitner Institute, Glienicker str 100, 14109 Berlin (Germany)

    2004-11-01

    Two Triple Axis spectrometers are commissioned now at the Budapest Neutron Center. The Thermal Triple Axis Spectrometer (TAST) is installed on the 8-th beam (60 mm diameter) and supplied with a 120 mm-long sapphire crystal placed inside the channel (2 m far from monochromator) to filter fast neutrons. The Eulerian cradle can be placed at the sample position to carry out holographic measurements. Otherwise a normal goniometer (carrying up to 100 kg weight for orientation, e.g. Cryostat/magnet/heavy sample) is used. This spectrometer's resolution was modeled by VITESS program package. The second (cold) neutron spectrometer (ATHOS) on a curved (4200 m) neutron guide is mounted at the 19 m-position from the cold source. The neutron guide 1.5{theta}{sub c}, made of boron glass, is coated with NiTi multilayer. This instrument, developed into the RITA-type spectrometer, is supplied with a 190 x 190 mm{sup 2} position sensitive detector and a polarization option (stacked polarizer). In addition it has the optional COMPACT Neutron Spin Echo setup, based on Larmor precession, for energy analysis with the resolution of 10 {mu}eV. The test measurements are presented. (copyright 2004 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 77; Issue 4. Issue front cover thumbnail. Volume 77, Issue 4. October 2011, pages 599-764. pp 599-609 Research Articles. Evaluation of response matrix of a multisphere neutron spectrometer with water moderator · Rahim Khabaz Hashem Miri Hakimabad.

  9. Insight on agglomerates of gold nanoparticles in glass based on surface plasmon resonance spectrum: study by multi-spheres T-matrix method

    Science.gov (United States)

    Avakyan, L. A.; Heinz, M.; Skidanenko, A. V.; Yablunovski, K. A.; Ihlemann, J.; Meinertz, J.; Patzig, C.; Dubiel, M.; Bugaev, L. A.

    2018-01-01

    The formation of a localized surface plasmon resonance (SPR) spectrum of randomly distributed gold nanoparticles in the surface layer of silicate float glass, generated and implanted by UV ArF-excimer laser irradiation of a thin gold layer sputter-coated on the glass surface, was studied by the T-matrix method, which enables particle agglomeration to be taken into account. The experimental technique used is promising for the production of submicron patterns of plasmonic nanoparticles (given by laser masks or gratings) without damage to the glass surface. Analysis of the applicability of the multi-spheres T-matrix (MSTM) method to the studied material was performed through calculations of SPR characteristics for differently arranged and structured gold nanoparticles (gold nanoparticles in solution, particles pairs, and core–shell silver–gold nanoparticles) for which either experimental data or results of the modeling by other methods are available. For the studied gold nanoparticles in glass, it was revealed that the theoretical description of their SPR spectrum requires consideration of the plasmon coupling between particles, which can be done effectively by MSTM calculations. The obtained statistical distributions over particle sizes and over interparticle distances demonstrated the saturation behavior with respect to the number of particles under consideration, which enabled us to determine the effective aggregate of particles, sufficient to form the SPR spectrum. The suggested technique for the fitting of an experimental SPR spectrum of gold nanoparticles in glass by varying the geometrical parameters of the particles aggregate in the recurring calculations of spectrum by MSTM method enabled us to determine statistical characteristics of the aggregate: the average distance between particles, average size, and size distribution of the particles. The fitting strategy of the SPR spectrum presented here can be applied to nanoparticles of any nature and in

  10. A large angle cold neutron bender using sequential garland reflections for pulsed neutron source

    International Nuclear Information System (INIS)

    Ebisawa, T.; Tasaki, S.; Soyama, K.; Suzuki, J.

    2001-01-01

    We discuss a basic structure and performance of a new cold neutron bender using sequential garland reflections, in order to bend a neutron beam with large divergence by large angle. Using this bender for a pulsed neutron source we could not only avoid the frame overlap for cold neutrons but also install a plural spectrometers at a cold guide and obtain polarized neutron beams if necessary. (author)

  11. Current status of neutron scattering facilities in Serpong

    International Nuclear Information System (INIS)

    Ikram, Abarrul

    1999-01-01

    Brief explanation of the research reactor as a neutron source is presented together with its current operation mode. The neutron beam facilities include one diffractometer for residual stress measurement, one diffractometer for single crystal structural determination and texture measurement, one high resolution powder diffractometer, one neutron radiography facility, one triple axis spectrometer, one small angle neutron scattering spectrometer and one high resolution small angle neutron scattering spectrometer. Current status of three instruments mostly related to this workshop, their performances and problems faced in the last year are presented as well as the future plan for refurbishment and development. (author)

  12. VERITAS: Versatile Triple-Axis Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Il

    2006-04-15

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, {approx} 5 m Curved Guide, {approx} 26 m w/ R 1500 m Straight Guide before the Instrument, {approx} 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world.

  13. VERITAS: Versatile Triple-Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sung Il

    2006-04-01

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, ∼ 5 m Curved Guide, ∼ 26 m w/ R 1500 m Straight Guide before the Instrument, ∼ 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world

  14. Neutron beam instruments for neutron science at HANARO

    International Nuclear Information System (INIS)

    Kim, Y.K.

    2009-01-01

    HANARO (Highly Advanced Neutron Application Reactor) came on line as the first criticality achieved in 1995. Since then a lot of experimental facilities for various utilizations have been gradually installed over the years up until now. Neutron science actually began with the neutron radiography facility completed in 1997. Thereafter, a series of thermal neutron beam instruments have been added and opened for the users. Some of them are high resolution power diffractometer, four circle diffractometer, small angle neutron spectrometer, and vertical-type reflectometer. The cold neutron research facility project was initiated in 2003, which envisions installation of cold neutron source, related systems, 5 neutron guides, and 7 instruments to satisfy the needs of cold neutron beam as the indispensable tool in NT, BT and other emerging technologies. Cold neutron guide building had been completed in October, 2008. Cold neutrons are planned to be produced later this year. Installations of neutron guides and associated instruments are to be finalized by the middle of 2010, ready for use. A 20 m detector vacuum tank and 20 m pre-sample flight path for 40 m SANS are already in place at the guide hall. Currently, there are about 450 users working with thermal neutron instruments. Once cold neutron instruments are available, we expect the number of users will double within next 3 years. (author)

  15. Neutron physics

    International Nuclear Information System (INIS)

    Beckurts, K.H.; Wirtz, K.

    1974-01-01

    This textbook consists of four sections which deal with the following subjects: 1. Production of neutrons and their interactions with the nuclei; neutron sources; neutron detectors; cross-section measurements. 2. Theory of neutron interactions with macroscopic media; neutron slowing down; space distribution of moderated neutrons; neutron thermalization; neutron scattering. 3. Radioactive probe measurements of thermal neutron fluxes; activation by means of epithermal neutrons; threshold detectors of fast neutrons; neutron calibration. 4. Neutron energy; slowing down kernels; neutron age; diffusion length and absorption of neutrons

  16. Different spectra with the same neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Ortiz R, J. M.; Hernandez D, V. M.; Martinez B, M. R.; Hernandez A, B.; Ortiz H, A. A. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Mercado, G. A., E-mail: fermineutron@yahoo.co [Universidad Autonoma de Zacatecas, Unidad Academica de Matematicas, Jardin Juarez No. 147, 98000 Zacatecas (Mexico)

    2010-02-15

    Using as source term the spectrum of a {sup 239}Pu-Be source several neutron spectra have been calculated using Monte Carlo methods. The source term was located in the centre of spherical moderators made of light water, heavy water and polyethylene of different diameters. Also a {sup 239}Pu-Be source was used to measure its neutron spectrum, bare and moderated by water. The neutron spectra were measured at 100 cm with a Bonner spheres spectrometer. Monte Carlo calculations were used to calculate the neutron spectra of bare and water-moderated spectra that were compared with those measured with the spectrometer. Resulting spectra are similar to those found in power plants with PWR, BWR and Candu nuclear reactors. Beside the spectra the dosimetric features were determined. Using moderators and a single neutron source can be produced neutron spectra alike those found in workplaces, this neutron fields can be utilized to calibrate neutron dosimeters and area monitors. (Author)

  17. Different spectra with the same neutron source

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Hernandez D, V. M.; Martinez B, M. R.; Hernandez A, B.; Ortiz H, A. A.; Mercado, G. A.

    2010-01-01

    Using as source term the spectrum of a 239 Pu-Be source several neutron spectra have been calculated using Monte Carlo methods. The source term was located in the centre of spherical moderators made of light water, heavy water and polyethylene of different diameters. Also a 239 Pu-Be source was used to measure its neutron spectrum, bare and moderated by water. The neutron spectra were measured at 100 cm with a Bonner spheres spectrometer. Monte Carlo calculations were used to calculate the neutron spectra of bare and water-moderated spectra that were compared with those measured with the spectrometer. Resulting spectra are similar to those found in power plants with PWR, BWR and Candu nuclear reactors. Beside the spectra the dosimetric features were determined. Using moderators and a single neutron source can be produced neutron spectra alike those found in workplaces, this neutron fields can be utilized to calibrate neutron dosimeters and area monitors. (Author)

  18. Neutron spectrometry

    International Nuclear Information System (INIS)

    Grimm, H.

    1978-01-01

    The paper begins by explaining the relation between measured signal and scattering function. This relation is determined by the resolution function which is a characteristic feature of every spectrometer. This is followed by a description of the various spectrometer components, such as: collimator, crystal, mechanical velocity selectros, polarisation analysis. Special types of spectrometers are also discussed: Two-axis spectrometers, spectrometers with mean resolution (Three-axis spectrometers, time-of-flight spectrometers), spectrometers with high energy resolution (back-scattering spectrometer, spin-echo spectrometer. Finally, a task is given showing the measuring range of various spectrometer types. (orig.) [de

  19. UCN gravity spectrometry using neutron interference filters for fundamental investigations in neutron optics

    CERN Document Server

    Bondarenko, I V; Cimmino, A; Geltenbort, P; Frank, A I; Hoghoj, P; Klein, A G; Masalovich, S V; Nosov, V G

    2000-01-01

    A Gravity Spectrometer for ultra-cold neutrons (UCN) using neutron interference filters has been designed and tested. An energy resolution of the order of 6.5 neV was obtained which is good enough for performing a number of neutron-optical experiments proposed in an earlier paper. Experimental tests of the UCN dispersion law are currently in progress.

  20. Triple-axis spectrometer

    International Nuclear Information System (INIS)

    Toeroek, Gy.

    2001-01-01

    A triple-axis spectrometer has been designed for structural and dynamical studies of condensed matter. Because of the limited number of other operational equipment the triple axis spectrometer was used in a multi purpose regime, e.g. high resolution diffractometry, strain analysis, reflectometry, quasielastic and inelastic scattering. A polarization setup was also tested on this spectrometer. (R.P.)

  1. The Triple Axis and SPINS Spectrometers.

    Science.gov (United States)

    Trevino, S F

    1993-01-01

    In this paper are described the triple axis and spin polarized inelastic neutron scattering (SPINS) spectrometers which are installed at the NIST Cold Neutron Research Facility (CNRF). The general principle of operation of these two instruments is described in sufficient detail to allow the reader to make an informed decision as to their usefulness for his needs. However, it is the intention of the staff at the CNRF to provide the expert resources for their efficient use in any given situation. Thus, this work is not intended as a user manual but rather as a guide into the range of applicability of the two instruments.

  2. The triple axis and SPINS spectrometers

    International Nuclear Information System (INIS)

    Trevino, S.F.

    1993-01-01

    In this paper are described the triple axis and spin polarized inelastic neutron scattering (SPINS) spectrometers which are installed at the NIST Cold Neutron Research Facility (CNRF). The general principle of operation of these two instruments is described in sufficient detail to allow the reader to make an informed decision as to their usefulness for his needs. However, it is the intention of the staff at the CNRF to provide the expert resources for their efficient use in any given situation. Thus, this work is not intended as a user manual but rather as a guide into the range of applicability of the two instruments

  3. Applications of Bonner sphere detectors in neutron field dosimetry

    International Nuclear Information System (INIS)

    Awschalom, M.; Sanna, R.S.

    1983-09-01

    The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed

  4. Data acquisition and instrument control system for neutron ...

    Indian Academy of Sciences (India)

    A personal computer (PC)-based data acquisition and instrument control system has been developed for neutron spectrometers in Dhruva reactor hall and Guide Tube laboratory. Efforts have been made to make the system versatile so that it can be used for controlling various neutron spectrometers using single end-on ...

  5. Resolution of a triple axis spectrometer

    DEFF Research Database (Denmark)

    Nielsen, Mourits; Bjerrum Møller, Hans

    1969-01-01

    A new method for obtaining the resolution function for a triple-axis neutron spectrometer is described, involving a combination of direct measurement and analytical calculation. All factors which contribute to the finite resolution of the instrument may be taken into account, and Gaussian...... or experimentally determined probability distributions may be used. The application to the study of the dispersion relation for excitations in a crystal is outlined...

  6. PNG-300 a nanosecond pulsed neutron generator

    International Nuclear Information System (INIS)

    Sztaricskai, T.; Vasvary, L.; Petoe, G.C.; Devkin, B.V.

    1985-01-01

    The design and operation of a nanosecond-pulse neutron generator is reported. It was constructed for the measurement of prompt neutron and gamma radiation in experimental studies of fast neutron reactions by time of flight techniques. The acceleration voltage is 300 kV and the total resolution of the generator-neutron spectrometer system is 2 ns. The ion-optical system, the vacuum system and the control of the neutron generator is described in detail. The equipment was used for prompt neutron and gamma radiation induced in construction materials. (R.P.)

  7. Dynamic diffraction of neutrons on perfect crystals

    International Nuclear Information System (INIS)

    Abov, Yu.G.; Tyulyusov, A.N.; Elyutin, N.O.

    2002-01-01

    Theory and experimental results are presented for the phenomena observed in the interaction of a thermal neutron beam with a regular periodic system of nuclei, which constitutes a perfect crystal. Recent studies in this field resulted in the appearance of new trends in the neutron optics, such as neutron interferometry and topography. High angular- and energy-resolution neutron crystal spectrometers were designed and manufactured for the investigation of small-angle and diffractive scattering. Passable new theoretical description of neutron dynamic diffraction and new experiments with neutron beams are discussed [ru

  8. Dynamic diffraction of neutrons on perfect crystals

    CERN Document Server

    Abov, Y G; Elyutin, N O

    2002-01-01

    Theory and experimental results are presented for the phenomena observed in the interaction of a thermal neutron beam with a regular periodic system of nuclei, which constitutes a perfect crystal. Recent studies in this field resulted in the appearance of new trends in the neutron optics, such as neutron interferometry and topography. High angular- and energy-resolution neutron crystal spectrometers were designed and manufactured for the investigation of small-angle and diffractive scattering. Passable new theoretical description of neutron dynamic diffraction and new experiments with neutron beams are discussed

  9. Spherical grating spectrometers

    Science.gov (United States)

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  10. The VERDI fission fragment spectrometer

    International Nuclear Information System (INIS)

    Fregeau, M. O.; Brys, T.; Gamboni, T.; Geerts, W.; Oberstedt, S.; Oberstedt, A.; Borcea, R.

    2013-01-01

    The VERDI time-of-flight spectrometer is dedicated to measurements of fission product yields and of prompt neutron emission data. Pre-neutron fission-fragment masses will be determined by the double time-of-flight (TOF) technique. For this purpose an excellent time resolution is required. The time of flight of the fragments will be measured by electrostatic mirrors located near the target and the time signal coming from silicon detectors located at 50 cm on both sides of the target. This configuration, where the stop detector will provide us simultaneously with the kinetic energy of the fragment and timing information, significantly limits energy straggling in comparison to legacy experimental setup where a thin foil was usually used as a stop detector. In order to improve timing resolution, neutron transmutation doped silicon will be used. The high resistivity homogeneity of this material should significantly improve resolution in comparison to standard silicon detectors. Post-neutron fission fragment masses are obtained form the time-of-flight and the energy signal in the silicon detector. As an intermediary step a diamond detector will also be used as start detector located very close to the target. Previous tests have shown that poly-crystalline chemical vapour deposition (pCVD) diamonds provides a coincidence time resolution of 150 ps not allowing complete separation between very low-energy fission fragments, alpha particles and noise. New results from using artificial single-crystal diamonds (sCVD) show similar time resolution as from pCVD diamonds but also sufficiently good energy resolution. (authors)

  11. Development of An Epi-thermal Neutron Field for Fundamental Researches for BNCT with A DT Neutron Source

    Directory of Open Access Journals (Sweden)

    Osawa Yuta

    2017-01-01

    Full Text Available Boron Neutron Capture Therapy (BNCT is known to be a new promising cancer therapy suppressing influence against normal cells. In Japan, Accelerator Based Neutron Sources (ABNS are being developed for BNCT. For the spread of ABNS based BNCT, we should characterize the neutron field beforehand. For this purpose, we have been developing a low-energy neutron spectrometer based on 3He position sensitive proportional counter. In this study, a new intense epi-thermal neutron field was developed with a DT neutron source for verification of validity of the spectrometer. After the development, the neutron field characteristics were experimentally evaluated by using activation foils. As a result, we confirmed that an epi-thermal neutron field was successfully developed suppressing fast neutrons substantially. Thereafter, the neutron spectrometer was verified experimentally. In the verification, although a measured detection depth distribution agreed well with the calculated distribution by MCNP, the unfolded spectrum was significantly different from the calculated neutron spectrum due to contribution of the side neutron incidence. Therefore, we designed a new neutron collimator consisting of a polyethylene pre-collimator and boron carbide neutron absorber and confirmed numerically that it could suppress the side incident neutrons and shape the neutron flux to be like a pencil beam.

  12. The SPEDE spectrometer

    Science.gov (United States)

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  13. Precision neutron polarimetry for neutron beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Penttila, S. I. (Seppo I.); Bowman, J. D. (J. David)

    2004-01-01

    The abBA collaboration is developing a new type of field-expansion spectrometer for measurement of the three correlation coefficients a, A, and B and shape parameter b. The measurement of A and B requires precision neutron polarimetry. We will polarize a pulsed cold neutron beam from SNS using a {sup 3}He neutron spin filter. The well-known polarizing cross section for n-{sup 3}He has 1/v dependence, which is used to determine the absolute beam polarization through a time-of-flight (TOF) measurement. We show that measuring the TOF dependence of A and B, the coefficients and the neutron polarization can be determined with small loss of statistical precision and negligible systematic error. We conclude that it is possible to determine the neutron polarization averaged over a run in the neutron beta decay experiment to better than 10{sup -3}. We discuss various sources of systematic uncertainties in the measurement of A and B and conclude that they are less than 10{sup -4}.

  14. Precision neutron polarimetry for neutron beta decay

    International Nuclear Information System (INIS)

    Penttila, S.I.; Bowman, J.D.

    2004-01-01

    The abBA collaboration is developing a new type of field-expansion spectrometer for measurement of the three correlation coefficients a, A, and B and shape parameter b. The measurement of A and B requires precision neutron polarimetry. We will polarize a pulsed cold neutron beam from SNS using a 3 He neutron spin filter. The well-known polarizing cross section for n- 3 He has 1/v dependence, which is used to determine the absolute beam polarization through a time-of-flight (TOF) measurement. We show that measuring the TOF dependence of A and B, the coefficients and the neutron polarization can be determined with small loss of statistical precision and negligible systematic error. We conclude that it is possible to determine the neutron polarization averaged over a run in the neutron beta decay experiment to better than 10 -3 . We discuss various sources of systematic uncertainties in the measurement of A and B and conclude that they are less than 10 -4 .

  15. Experimental technique of small angle neutron scattering

    International Nuclear Information System (INIS)

    Xia Qingzhong; Chen Bo

    2006-03-01

    The main parts of Small Angle Neutron Scattering (SANS) spectrometer, and their function and different parameters are introduced from experimental aspect. Detailed information is also introduced for SANS spectrometer 'Membrana-2'. Based on practical experiments, the fundamental requirements and working condition for SANS experiments, including sample preparation, detector calibration, standard sample selection and data preliminary process are described. (authors)

  16. Time-of-flight isochronous spectrometer

    International Nuclear Information System (INIS)

    Wouters, J.M.; Vieira, D.J.; Wollnik, H.

    1985-01-01

    This report is the second in a series of progress reports describing the design and construction of the time-of-flight isochronous (TOFI) spectrometer and its associated secondary beam line. TOFI, which is being constructed jointly by INC and MP Divisions, is designed to measure in a systematic fashion the ground-state masses of the light neutron-rich nuclei with A<70 that lie far from the valley of β stability. In the past year the authors ordered all the long-lead items necessary for construction of the spectrometer and installed the first half of the secondary beam line. Furthermore, a major portion of the control system for both the spectrometer and beam line was designed and installed. This annual report briefly summarizes the current status of the spectrometer and describes in some detail the design and installation of the first half of the transport line. For a summary of the scientific goals and overall design of the TOFI spectrometer, see the 1983 Progress at LAMPF report

  17. Polarisation modulated crosscorrelation spectroscopy on a pulsed neutron source

    International Nuclear Information System (INIS)

    Cywinski, R.; Williams, W.G.

    1984-07-01

    A crosscorrelation technique is introduced by which a total scattering polarisation analysis spectrometer on a pulsed neutron source can be modified to give full neutron polarisation and energy analysis without changing the physical configuration of the instrument. Its implementation on the proposed POLARIS spectrometer at the Rutherford Appleton Laboratory Spallation Neutron Source is described, and the expected dynamic (Q, ω) range and resolution evaluated. (author)

  18. New Techniques in Neutron Scattering

    DEFF Research Database (Denmark)

    Birk, Jonas Okkels

    potential performance than any existing facility, however in order to use this pulse structure optimally many existing neutron scattering instruments will need to be redesigned. This defense will concentrate on the design and optimization of the inverse time-of-flight cold neutron spectrometer CAMEA......, simulations and prototyping to optimize the instrument and ensure that it will deliver the predicted performance when constructed. During the design a new prismatic analyser concept that can be of interest to many other neutron spectrometers was developed. The design work was compiled into an instrument......Neutron scattering is an important experimental technique in amongst others solid state physics, biophysics, and engineering. This year construction of European Spallation Source (ESS) was commenced in Lund, Sweeden. The facility will use a new long pulsed source principle to obtain higher...

  19. Opening the terahertz window on the OSIRIS spectrometer

    Directory of Open Access Journals (Sweden)

    Demmel F.

    2015-01-01

    Full Text Available A cooled and mechanically retractable beryllium filter has been installed and commissioned on the low-energy OSIRIS spectrometer at ISIS. This instrument development extends the energy-transfer range of the spectrometer up to ca. 20 meV (∼ 5 THz, leading to an excellent resolution at THz frequencies and substantial gains in detected flux relative to existing capabilities on the neighbouring IRIS spectrometer. Herein, we provide a concise account of this new capability for high-resolution neutron spectroscopy in the THz domain, as well as outline a number of ongoing and potential scientific opportunities in condensed-matter physics, chemistry, and materials science.

  20. Differential neutron spectrometry in the very low neutron energy range. Neutron cross sections for Zr, Al, polyethylene and liquid fluoropolymers

    International Nuclear Information System (INIS)

    Pokotilovskij, Yu.N.; Novopol'tsev, M.I.; Geltenbort, P.; Brenner, T.

    2003-01-01

    Some results of the test of the time-of-flight neutron spectrometers in the energy range (0.05-2.5)μeV are described. The measurements of total and differential cross sections were performed for several substances relevant to the experiments in the physics of ultracold neutrons: Zr, Al, polyethylene and liquid fluoropolymers

  1. The Omicron Spectrometer

    CERN Document Server

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  2. ODY MARS GAMMA RAY SPECTROMETER 5 AHD V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The Odyssey Gamma Ray Spectrometer (GRS) Averaged HEND Data (AHD) products are temporally and spatially binned neutron counting rates and fluxes that can be used to...

  3. Neutron scattering. Lectures of the JCNS laboratory course held at Forschungszentrum Juelich and the research reactor FRM II of TU Munich

    International Nuclear Information System (INIS)

    Brueckel, T.; Heger, G.; Richter, D.; Zorn, R.

    2007-01-01

    The following topics are dealt with: Fourier transform, basic assumptions of quantum mechanics and the Born approximation, symmtery in crystals, neutron sources, neutron elastic scattering and properties, polarized neutron scattering, correlation functions measured by scattering experiments, grazing incidence neutron scattering, neutron diffractometers, small-angle scattewring inelastic crystal spectrometers, time-of-flight spectrometers using NSE, structure determination, inelastic neutron scattering with phonon and magnon excitations, structure of complex fluids and macromolecules, polymer dynamics, magnetism. (HSI)

  4. Progress in neutron beam development at the HFR Petten (feasibility study for a BNCT facility)

    International Nuclear Information System (INIS)

    Constantine, G.; Moss, R.L.; Watkins, P.R.D.; Perks, C.A.; Delafield, H.J.; Ross, D.; Voorbraak, W.P.; Paardekooper, A.; Freudenreich, W.E.; Stecher-Rasmussen, F.

    1990-08-01

    Boron Neutron Capture Therapy, using intermediate energy neutrons to achieve the deep penetration essential for treating brain tumours, can be implemented with a filtered reactor neutron beam. This is designed to minimize the mean energy of the neutrons to keep proton recoil damage to the scalp within normal tissue tolerance limits whilst delivering the required thermal neutron fluence to the tumour over a reasonably short period. This can only be realized in conjunction with a high power density reactor. At the Joint Research Centre Petten an optimized neutron filter is currently being built for installation into the HB11 beam tube of the High Flux Reactor HFR. Part of the development leading to this design has been an extensive study of broad spectrum, filtered beam performance on the HB7 beam tube facility. A wide range of calculations was performed using the Monte Carlo code, MCPN, supported by validation experiments in which several filter configuration incorporating aluminium, sulphur, liquid argon, titanium and cadmium were installed for low power measurements of the neutron fluence rate, neutron spectra and beam gamma-ray contamination. The measurements were carried out within a successful European collaboration. Evaluations were made of the reactor core edge and unfiltered beam spectra, for comparison with MCNP calculations. Multi-foil activation methods and also gamma dose determination in the filtered beam using thermo-luminescent detectors were performed by the ECN. The Harwell/ Birmingham University collaborators undertook the neutron spectrum measurements in the filtered beam. proton recoil spectrometry was used above 30 keV, combined with a multi-sphere and BF 3 chamber response modification technique. Subsequent spectrum adjustment was carried out with the SENSAK code. The agreement between the calculated and measured spectra has given confidence in the reactor and filter modelling methods used to design the HB11 therapy facility. (author). 12 refs

  5. Interest of neutrons for material characterization

    International Nuclear Information System (INIS)

    Novion, C. de

    1996-01-01

    After a review of the characteristics of the neutron-matter interaction, the principles of a neutron spectrometer and the main applications of thermal neutrons in metallurgy, the advantages and inconvenients of neutrons and X rays are compared. Several examples of neutron diffraction applications when X rays are not well adapted are presented: separation of neighbouring atomic number elements, study of interstitial compounds, determination of crystalline structures through Bragg diffraction, precipitation studies by small angle scattering: precipitation in irradiated vessel steels, precipitation of copper rich clusters in iron based diluted alloys, thermal ageing of austenitic-ferritic steels

  6. Rotating crystal pulse shaper for use on a pulsed neutron source

    International Nuclear Information System (INIS)

    Carpenter, J.M.; Carlile, C.J.

    1983-01-01

    A pulse shortening device is described for use on pulsed thermal neutron sources. The device employs rotating single crystals and has applications in the design of high resolution cold neutron spectrometers

  7. The determination of neutron energy spectra of radioisotope sources

    International Nuclear Information System (INIS)

    Lutkin, J.E.

    1975-08-01

    The neutron energy spectrum of a 241 Am-Be radioisotope neutron source has been determined by use of a time of flight neutron spectrometer; this spectrometer not being subject to the same uncertainties as a scintillation spectrometer. Neutron spectra have been determined using a scintillation spectrometer with which the effects of instrumental uncertainties, particularly the pulse shape discrimination have been assessed. In the course of the development of the time flight spectrometer a zero crossover pulse shape discrimination system was developed in order to reduce the unwanted background. Using this system a quantitative survey of pulse shape discrimination with experimental and commercial liquid and plastic organic scintillators were carried out. In addition the pulse shape discrimination properties of inorganic scintillators were also examined. (author)

  8. Calibration of the IRD two-component TLD albedo neutron dosemeter in some moderated neutron fields

    International Nuclear Information System (INIS)

    Freitas, Bruno M.; Silva, Ademir X. da

    2015-01-01

    In some stray neutron fields, like those found in practices involving the handling of radionuclide sources, the neutron calibration factor for albedo neutron dosemeter can vary widely compared to the factor for bare sources. This is the case for well logging, which is the area with the largest number of workers exposed to neutrons in Brazil. The companies employ routinely 241 Am-Be neutron sources. The albedo response variation is mainly due to the presence of scattered and moderated neutrons. This paper studies the response variation of the two-component TLD albedo neutron dosemeter used in the neutron individual monitoring service of Instituto de Radioprotecao e Dosimetria, in different radionuclide neutron source beams. The neutron spectra were evaluated applying a Bonner sphere spectrometer with a 6 LiI(Eu) detector in the Brazilian National Metrology Neutron Laboratory. Standard neutron sources of 241 Am-Be and 252 Cf were employed, besides 238 Pu-Be. Measurements were also made with scattered and moderated neutron beams, including 252 Cf(D 2 O) reference spectrum, 241 Am-Be moderated with paraffin and silicone and a thermal neutron flux facility. New neutron calibration factors, as a function of the incident to albedo neutron ratio, were proposed for use in the albedo algorithm for occupational fields where the primary neutron beam is one of those studied sources. (author)

  9. Resolution and intensity in neutron spectrometry determined by Monte Carlo simulation

    DEFF Research Database (Denmark)

    Dietrich, O.W.

    1968-01-01

    The Monte Carlo simulation technique was applied to the propagation of Bragg-reflected neutrons in mosaic single crystals. The method proved to be very useful for the determination of resolution and intensity in neutron spectrometers.......The Monte Carlo simulation technique was applied to the propagation of Bragg-reflected neutrons in mosaic single crystals. The method proved to be very useful for the determination of resolution and intensity in neutron spectrometers....

  10. Development and calibration of large volume proton-recoil counters for neutron spectrometry in radiological protection

    International Nuclear Information System (INIS)

    Delafield, H.J.; Birch, R.

    1988-08-01

    A transportable neutron spectrometry system of high sensitivity, based on four cylindrical proton-recoil proportional counters, has been developed for the high-resolution measurement of neutron spectra in the working environment at dose-equivalent rates in the range 5-50 μSv h -1 . The system uses modern compact electronics to provide simultaneous data acquisition with a single multichannel analyser. This report describes in detail the research and development undertaken to produce a set of four cylindrical counters to cover the neutron energy-range from about 50 keV to 2 MeV. Counter studies were made to optimize the type and size of anode wire, the gas fillings and manufacturing procedure. The counters were calibrated at the National Physical Laboratory using monoenergetic neutrons, incident side-on and end-on, to provide measured response functions, energy and fluence calibrations. The system will generally be used together with a set of multispheres, to measure the dose-equivalent below 50 keV, and an α-recoil proportional counter to extend the spectral measurement up to 15 MeV. (author)

  11. TOFI: An isochronous time-of-flight mass spectrometer

    International Nuclear Information System (INIS)

    Wollnik, H.

    1987-01-01

    A time-of-flight mass spectrometer was constructed to measure the masses of neutron-rich recoils produced in proton-induced fragmentation reactions. This system consists of four sector magnets designed such that the overall flight time is independent of the velocity of the recoil ions and thus depends only on their mass-to-charge ratios. (orig.)

  12. Fourier Transform Spectrometer System

    Science.gov (United States)

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  13. Improved Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Improved Mass Spectrometer project will develop system requirements and analyze the path to space qualification.   The results of this project...

  14. Micro Plasma Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  15. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  16. Neutral Kaon Spectrometer 2

    Science.gov (United States)

    Kaneta, M.; Beckford, B.; Fujii, T.; Fujii, Y.; Futatsukawa, K.; Han, Y. C.; Hashimoto, O.; Hirose, K.; Ishikawa, T.; Kanda, H.; Kimura, C.; Maeda, K.; Nakamura, S. N.; Suzuki, K.; Tsukada, K.; Yamamoto, F.; Yamazaki, H.

    2018-04-01

    A large-acceptance spectrometer, Neutral Kaon Spectrometer 2 (NKS2), was newly constructed to explore various photoproduction reactions in the gigaelectronvolt region at the Laboratory of Nuclear Science (LNS, currently ELPH), Tohoku University. The spectrometer consisted of a dipole magnet, drift chambers, and plastic scintillation counters. NKS2 was designed to separate pions and protons in a momentum range of less than 1 GeV/ c, and was placed in a tagged photon beamline. A cryogenic H2/D2 target fitted to the spectrometer were designed. The design and performance of the detectors are described. The results of the NKS2 experiment on analyzing strangeness photoproduction data using a 0.8-1.1 GeV tagged photon beam are also presented.

  17. Volume 15. Neutron scattering

    International Nuclear Information System (INIS)

    Kostorz, G.

    1979-01-01

    This volume of the Treatise on Materials Science and Technology shows how neutron scattering methods can be used to obtain important information on materials, by guiding the reader through the principles and describing recent applications. Materials scientists, but also solid state physicists, physical chemists, and metallurgists interested in this field, will find a completely referenced survey of the ''classical topics'' of neutron scattering and a more detailed presentation of methods and techniques that are more specifically related to materials science. After a brief review of the general principles in the first chapter, subsequent chapters concentrate on particular methods and problems. The techniques used in neutron crystallography are presented, and selected applications of nuclear and magnetic scattering are discussed. The measurement of phonons, their role in phase transformations, and their behavior in the presence of crystal defects are considered, and quasi-elastic scattering is given detailed treatment. The methods of small-angle scattering and diffuse scattering have been developed to a considerable perfection in recent years and are presented in detail. The structure and dynamics of hydrogen dissolved in metals and the conformation and dynamics of polymers are two outstanding subjects to which neutron scattering has contributed so much in recent years that separate chapters are devoted to covering these fields. Finally, the choice of the appropriate materials is also becoming increasingly crucial in the design and construction of neutron spectrometers. Therefore, the last chapter deals with special materials problems in neutron devices

  18. Half-life and delayed neutron emission probabilities measurement of 44S,45-47Cl spectrometer: their implication in the 48Ca/46Ca ratio understanding in the solar system

    International Nuclear Information System (INIS)

    Sorlin, O.

    1991-06-01

    After a detailed description of the simulation program LISE, experimental measurements of the radioactive decay (half-lives and neutron delayed emission probabilities) of the neutron rich nuclei 44 S, 45 Cl, 47 Cl are presented. The comparison between these results and the theoretical predictions clearly shows that mass and deformation measurements of these nuclei are very important to determine precisely the radioactive decay parameters necessary to astrophysics. Effectively, these ones are used in star evolution models to understand the elements abundance curve of the solar system. Even if the shape of this curve is well reproduced, some anomalies subsist. The experimental results seem to show that, with the constraints they bring, a double r process in low-mass supernovae of type II can explain twice the isotopic anomalies and the shape of the elements abundance curve

  19. A study of resolution function on a MIEZE spectrometer

    International Nuclear Information System (INIS)

    Hayashida, H; Hino, M; Kitaguchi, M; Kawabata, Y; Achiwa, N

    2008-01-01

    We have installed a MIEZE (modulated intensity by zero effort) spectrometer in the C3-1-2-2(MINE1) port at JRR-3M. In the MIEZE spectrometer, a sample is placed after the analyzer. Thus the contrast of the MIEZE signal can be observed without reduction even in the case of magnetic scattering where the signal for NSE (neutron spin echo) and NRSE (neutron resonance spin echo) instruments is less than half. The MIEZE signal is sensitive to the dispersion of neutron trajectories from the sample to the detector. In other words, the MIEZE signal is reduced only due to the dispersion even without in- and quasi-elastic scattering. We studied the correlation between experimental configuration and its resolution function using the Monte Carlo simulation. We prepared a magnetite ferrofluid sample with a typical particle diameter of 84 Å, and examined the simulation model by experiments

  20. Radiative neutron capture as a counting technique at pulsed spallation neutron sources: a review of current progress

    Science.gov (United States)

    Schooneveld, E. M.; Pietropaolo, A.; Andreani, C.; Perelli Cippo, E.; Rhodes, N. J.; Senesi, R.; Tardocchi, M.; Gorini, G.

    2016-09-01

    Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

  1. Recent progress in the chopper spectrometer, INC

    International Nuclear Information System (INIS)

    Itoh, Shinichi; Arai, Masatoshi; Kawai, Masayoshi

    2001-01-01

    A guide tube comprising supermirrors, of which the critical wavenumber is three times as large as that of natural nickel, was installed in the primary flight path of the chopper spectrometer, INC, at KENS. Also, the characteristics of the ambient-temperature H 2 O moderator, which INC is facing, was changed by renewal construction of the neutron source at KENS. We discuss here an improvement in the performance of INC by a comparison with the previous performance. We also report on the development on a goniometer for single-crystal experiments at low temperatures. (author)

  2. MA nuclear data measurement with lead slowing-down spectrometers

    International Nuclear Information System (INIS)

    Kobayashi, Katsuhei

    2000-01-01

    This paper reviews the minor actinide (MA) nuclear data measured with lead slowing-down spectrometers. The Kyoto University Lead Slowing-down Spectrometer (KULS) at the Research Reactor Institute, Kyoto University has been applied to the measurements of (1) the fission cross sections of Np-237, Am-241, Am-242m and Am-243 in the energy range from 0.1 eV to 10 keV and (2) the capture cross section of Np-237 at energies between 0.01 eV and 1 keV. The results are compared with the existing experimental and the evaluated nuclear data (ENDF/B-VI, JENDL-3.2 and JEF-2.2). The recent MA nuclear data, which were measured with the Rensselaer Intense Neutron Spectrometer (RINS) at the Rensselaer Polytechnic Institute and the spectrometer at the Kurchatov Institute, are also introduced. (author)

  3. Compton backscattering axial spectrometer

    International Nuclear Information System (INIS)

    Rad'ko, V.E.; Mokrushin, A.D.; Razumovskaya, I.V.

    1981-01-01

    Compton gamma backscattering axial spectrometer of new design with the 200 time larger aperture as compared with the known spectrometers at the equal angular resolution (at E=159 keV) is described. Collimator unit, radiation source and gamma detector are located in the central part of the spectrometer. The investigated specimen (of cylindrical form) and the so called ''black body'' used for absorption of photons, passed through the specimen are placed in the peripheric part. Both these parts have an imaginary symmetry axis that is why the spectrometer is called axial. 57 Co is used as the gamma source. The 122 keV spectral line which corresponds to the 83 keV backscattered photon serves as working line. Germanium disk detector of 10 mm diameter and 4 mm height has energy resolution not worse than 900 eV. The analysis of results of test measurements of compton water profile and their comparison with data obtained earlier show that only finity of detector resolution can essentially affect the form of Compton profile. It is concluded that the suggested variant of the spectrometer would be useful for determination of Compton profiles of chemical compounds of heavy elements [ru

  4. Study of materials properties by neutron beam applications

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Kim, H. J.; Kim, B. C.; Jun, B. C.; Lee, J. S.; Seong, B. S.; Shim, H. S.; Choi, B. H.; Ho, J. W.; Kang, S. K.; Kim, J. Y.; Park, D. K.; Kim, C. K.; Kim, C. J.; Cho, Y. S.

    1997-10-01

    Horizontal and vertical beam ports related works for neutron beam experimental facilities in HANARO has been done. And the preparation works of neutron spectrometers, design, manufacture and installation of the high resolution powder diffractometer, the four circle diffractometer, the polarized neutron spectrometer, the small angle neutron spectrometer and the position sensitive detector unit for residual stress measurement have been done. The status for each spectrometer are described. The development of neutron spectroscopy technique for the crystal structure analysis on YBa 2 Cu 3 O 7-x , U 3 Si, Pb(Yb,Nb)O 3 by neutron diffraction, the anisotropic properties of textured orthorhombic polycrystalline materials and the low temperature sample environment facility has been performed and neutron reflectometry has been reviewed. After the design and manufacture of neutron radiography facility, it has been installed at NR beam tube and its' performance evaluation has been done. The image processing technique for real time testing is under development. As for neutron transmutation doping, design of irradiation tube, estimation on neutron flux distribution and flux quality, and study of irradiation damage recovery under annealing have been tried. (author). 11 refs., 40 tabs., 86 figs.

  5. LANSCE '90: the Manuel Lujan Jr. Neutron Scattering Center

    International Nuclear Information System (INIS)

    Pynn, Roger

    1991-01-01

    This paper describes progress that has been made at the Manuel Lujan Jr. Neutron Scattering Center (LANSCE) during the past two years. Presently, LANSCE provides a higher peak neutron flux than any other pulsed spallation neutron source. There are seven spectrometers for neutron scattering experiments that are operated for a national user program sponsored by the U.S. Department of Energy. Two more spectrometers are under construction. Plans have been made to raise the number of beam holes available for instrumentation and to improve the efficiency of the target/moderator system. (author)

  6. LANSCE '90: The Manuel Lujan Jr. Neutron Scattering Center

    International Nuclear Information System (INIS)

    Pynn, R.

    1990-01-01

    This paper describes progress that has been made at the Manuel Lujan Jr. Neutron Scattering Center (LANSCE) during the past two years. Presently, LANSCE provides a higher peak neutron flux than any other pulsed spallation neutron source. There are seven spectrometers for neutron scattering experiments that are operated for a national user program sponsored by the US Department of Energy. Two more spectrometers are under construction. Plans have been made to raise the number of beam holes available for instrumentation and to improve the efficiency of the target/moderator system. 9 refs., 4 figs

  7. The dilepton spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yegneswaran, A.; Claesson, G.; Fulton, R.; Hendrie, D.L.; Krebs, G.F.; Lallier, E.; Letessier-Selvon, A.; Matis, H.S.; Mulera, T.; Naudet, C.; Nesbitt, D.; Roche, G.; Schroeder, L.S.; Seidl, P.A. (Lawrence Berkeley Lab., CA (USA)); Beedoe, S.; Bystricky, J.; Carroll, J.; Gordon, J.; Igo, G.; Oillataguerre, P. (California Univ., Los Angeles (USA)); Christo, S.; Gilot, J.F.; Kirk, P.; Wang, Z.; Xu, I. (Louisiana State Univ., Baton Rouge (USA)); Force, P.; Landaud, G. (Clermont-Ferrand-2 Univ., 63 - Aubiere (France)); Hallman, T.; Madansky, L.; Welsh, R. (Johns Hopkins Univ., Baltimore, MD (USA)); Miller, D. (Northwestern Univ., Evanston, IL (USA))

    1990-05-01

    The dilepton spectrometer (DLS) at Lawrence Berkeley Laboratory's Bevalac has been designed and constructed to investigate the production of electron-positron pairs with low mass and low transverse momentum in proton-nucleus and nucleus-nucleus collisions for incident-beam kinetic energies of 5 A GeV and less. This article briefly recalls the physics objectives of the program, discusses the methodology of the measurement, presents details of the design of the spectrometer and the detector elements, and reports on their performance. Selected experimental results are given to illustrate the capability of the DLS and to demonstrate the level to which it is possible to realize the physics objectives with the spectrometer. (orig.).

  8. The Manuel Lujan, Jr. Neutron Scattering Center LANSCE experiment reports 1989 run cycle

    Energy Technology Data Exchange (ETDEWEB)

    Hyer, D.K.; DiStravolo, M.A. (comps.)

    1990-10-01

    This report contains a listing and description of experiments carried on at the LANSCE neutron scattering facility in the following areas: High Density Powder Diffraction; Neutron Powder Diffractometer, (NPD); Single Crystal Diffractometer, (SCD); Low-Q Diffractometer, (LQD); Surface Profile Analysis Reflectometer, (SPEAR); Filter Difference Spectrometer, (FDS); and Constant-Q Spectrometer.

  9. The Manuel Lujan, Jr. Neutron Scattering Center LANSCE experiment reports 1989 run cycle

    International Nuclear Information System (INIS)

    Hyer, D.K.; DiStravolo, M.A.

    1990-10-01

    This report contains a listing and description of experiments carried on at the LANSCE neutron scattering facility in the following areas: High Density Powder Diffraction; Neutron Powder Diffractometer, (NPD); Single Crystal Diffractometer, (SCD); Low-Q Diffractometer, (LQD); Surface Profile Analysis Reflectometer, (SPEAR); Filter Difference Spectrometer, (FDS); and Constant-Q Spectrometer

  10. Realization of two light particle correlation experiments: behaviour to very low relative momenta (measurement with a magnetic spectrometer) and influence of the violence of reaction on the emission sources (measured by the neutron detector ORION); Mise en oeuvre de deux experiences de correlations de particules legeres: comportement a tres faibles impulsions relatives (mesure avec un spectrometre magnetique) et influence de la violence de reaction sur les sources d`emission (mesuree avec le detecteur de neutrons ORION)

    Energy Technology Data Exchange (ETDEWEB)

    Sezac, L. [Grenoble-1 Univ., 38 (France)

    1993-01-20

    The correlation measurements between light particles emitted during heavy ion collisions allow to estimate the time-space extension of the emitting sources. This report about the preliminaries of two correlation experiments is split into two parts. The first one describes a test experiment, performed to study the feasibility of a correlation experiment at very low relative momenta with the help of a magnetic spectrometer. The results will allow to determine the still unknown relative effects from the final state interaction and the combination of both Coulomb interaction and quantum statistics. A correlation study without experimental selection of the impact parameter gives unclear answers about the sizes and the temporal characteristics of the emitting systems. The second part analyses the sources of the alpha particles detected in the reaction chamber of the multidetector ORION used as a violence of the reaction filter. The results show that it is possible to consider as a good filter a fast information called `prompt peak` (correlated to the neutron multiplicity detected with ORION). Under such conditions a study of two particle correlations from equilibrated systems with a reasonable statistics becomes thinkable. The results obtained allow to characterize the emitting sources (speed, intensity, temperature) as a function of the violence of the reaction for the system {sup 208} Pb + {sup 93} Nb at 29 MeV/u. (author) 85 refs.

  11. BIS-2 spectrometer for search and for investigation of narrow resonances

    International Nuclear Information System (INIS)

    Aleev, A.N.; Aref'ev, V.A.; Balandin, V.P.

    1991-01-01

    Configuration and main characteristics of the BIS-2 filmless spectrometer designed for search and study of charmed particles and narrow resonances generated in neutron-nuclear interactions are described. The spectrometer was arranged in neutral beam of the Serpukhov accelerator. Mean neutron energy is about 40 GeV. Main parts of the spectrometer are: spectrometric magnet, system of proportional chambers, system of charged particle identification, Cherenkov total-absorption spectrometer, system of scintillation counters, electronic equipment for event selection and data recording. The calculated and measured characteristics of separate parts and the system as a whole, as well as review of main results obtained by means of the BIS-2 spectrometer are given

  12. Ultracold and very cold neutron facility in KUR

    International Nuclear Information System (INIS)

    Kawabata, Yuji; Utsuro, Masahiko

    1992-01-01

    The present status of the ultracold and very cold neutron facility installed in the Kyoto University Reactor (KUR) is described in this presentation. It consists of a VCN (very cold neutrons) guide tube, a VCN bender and a supermirror neutron turbine. The guide tube extracts VCN from a liquid deuterium cold neutron source in a graphite thermal column and the neutron turbine converts VCN to UCN (ultracold neutrons). As for the utilization of the present facility, VCN radiography and an UCN gravity spectrometer are shown for the practical examples of the research with VCN and UCN. (author)

  13. Neutron scattering in ORNL's calibration facility

    International Nuclear Information System (INIS)

    Liu, J.C.; Sims, C.S.; Casson, W.H.; Murakami, H.

    1991-01-01

    Room scattering corrections for several common neutron detectors in a new neutron calibration facility at the Oak Ridge National Laboratory were measured. Results for three radioisotopic sources in ground scattering and enclosed room scattering situations are compared with two model calculations, and the agreement is good. A personnel neutron spectrometer was used to examine further the spectral variation inside the enclosed neutron room. Scattered fluence and scattered dose equivalent results from the spectral measurements indicate that the scattering predictions using models hold only for small-source-to-detector distances. Additional observations from this study are also presented. (author)

  14. The Omega spectrometer

    CERN Multimedia

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  15. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  16. MIRI spectrometer optical design

    NARCIS (Netherlands)

    Kruizinga, B.; Visser, H.; Pel, J.W.; Moddemeijer, K.; Smorenburg, C.

    2004-01-01

    MIRI (the Mid InfraRed Instrument) is one of the focal plane instruments of the James Webb Space Telescope. The instrument comprises a camera and a spectrometer module. The instrument plays the following key roles in the JWST science program. Discovery of the "first light". Assembly of galaxies:

  17. Magnetic spectrometer Grand Raiden

    International Nuclear Information System (INIS)

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  18. Heat of vaporization spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D. Jr.

    1979-03-01

    Multilayer desorption measurements of various substances adsorbed on a stainless-steel substrate are found to exhibit desorption profiles consistent with a zeroth-order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification.

  19. Heat of vaporization spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D. Jr.

    1978-01-01

    Multilayer desorption measurements of various substances adsorbed on a stainless steel substrate are found to exhibit desorption profiles consistent with a zeroth order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification.

  20. Contribution to construction and setup of a detection system for the focal plan of the BBS spectrometer. Application to study of the neutron emission decay of the resonant states populated by the reaction (4He,3He) at 42 MeV/u in nuclei 208Pb and 209Pb

    International Nuclear Information System (INIS)

    Plankl-Chabib, Elke

    1999-01-01

    In order to realize an experimental program dedicated to nuclear structure studies we have conceived and constructed at IPN Orsay a detection system for the focal plane of the magnetic spectrometer BBS, installed at the cryogenic cyclotron AGOR of the laboratory KVI (The Netherlands). Two detection units, consisting each of two localization plans of the Cathode Strip Chamber (CSC) type, measure the position and angle of particle trajectory. This information is used for the determination of the reaction parameters at the target by a backtracking procedure. The identification of the reaction products is done by the measurement of their time-of-flight and energy loss. For light ions this task is assumed by plastic scintillators, and for heavy ions by a parallel plan detector (PPAC) and an ionization chamber. This detection system is well adapted to the requirements given by the detection of a large range of ions (protons to 36 Ar at energies of several tenths of MeV/nucleon) as well as the big acceptance, the small dispersion and the aberration of the BBS. The results of the test show the good performances of the detection system. In a first experiment the focal plane detection system was coupled to the neutron multidetector EVEN in order to study the decay of resonant high spin states at high excitation energies by the ( 4 He, 3 He) reaction on 207 Pb and 208 Pb targets. The transfer spectra, inclusive and in coincidence, of the nuclei 208 Pb and 209 Pb show a striking resemblance except for an excitation energy shift which is due to the hole in the last neutron shell of 207 Pb. The resonances at l 8 and l = 9 are clearly populated, in agreement with the predictions of the Bonaccorso-Brink model. A sizeable fraction of the decay of the l = 8 resonance is direct, but at excitation energies higher than 15 MeV (in 208 Pb) the decay is mostly statistical. (author)

  1. Development of Cold Neutron Activation Station at HANARO Cold Neutron Source

    International Nuclear Information System (INIS)

    Sun, G. M.; Hoang, S. M. T.; Moon, J. H.; Chung, Y. S.; Cho, S. J.; Lee, K. H.; Park, B. G.; Choi, H. D.

    2012-01-01

    A new cold neutron source at the HANARO Research Reactor had been constructed in the framework of a five-year project, and ended in 2009. It has seven neutron guides, among which five guides were already allocated for a number of neutron scattering instruments. A new two-year project to develop a Cold Neutron Activation Station (CONAS) was carried out at the two neutron guides since May 2010, which was supported by the program of the Ministry of Education, Science and Technology, Korea. Fig. 1 shows the location of CONAS. CONAS is a complex facility including several radioanalytical instruments utilizing neutron capture reaction to analyze elements in a sample. It was designed to include three instruments like a CN-PGAA (Cold Neutron - Prompt Gamma Activation Analysis), a CN-NIPS (Cold Neutron - Neutron Induced Pair Spectrometer), and a CN-NDP (Cold Neutron - Neutron-induced prompt charged particle Depth Profiling). Fig. 2 shows the conceptual configuration of the CONAS concrete bioshield and the instruments. CN-PGAA and CN-NIPS measure the gamma-rays promptly emitted from the sample after neutron capture, whereas CN-NDP is a probe to measure the charged particles emitted from the sample surface after neutron capture. For this, we constructed two cold neutron guides called CG1 and CG2B guides from the CNS

  2. Users guide to the inelastic rotor spectrometer (IRS)

    International Nuclear Information System (INIS)

    Bunce, L.J.

    1987-11-01

    The paper is a users guide to the inelastic rotor spectrometer installed on the Harwell 136 Mev electron linear accelerator HELIOS. The spectrometer is designed to measure neutron inelastic scattering for energy transfers from 50 meV to 400 meV and covering a range of Q values from 1 to 15 A 0-1 . The guide contains a description of:- time-of-flight scales, run and sample changer control units, sample environment, detectors, rotor system, 600 Hz operation of rotor, a run, and data processing. (U.K.)

  3. A review on the study of polymer properties by Small Angle Neutron Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Baek Seok; Lee, Chang Hee; Sim, Hae Seop; Lee, Jung Sool [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of); Kim, Hong Doo [Kyunghee Univ., Seoul (Korea, Republic of); Kim, Eu Gene [Hongik Univ., Seoul (Korea, Republic of); Cha, Kuk Heon [Seoul National Univ., Seoul (Korea, Republic of)

    1998-05-01

    This report contains concept of small angle neutron scattering , various design features and considerations of the small angle neutron spectrometer at HANARO, and recent trends of polymer studies by using this SANS technique with the installation of the spectrometer in near future. We, therefore, wish to review feasibility of small angle studies for polymer field at this spectrometer and to help possible beam time users for their experimental consideration. (author). 23 refs., 7 tabs., 23 figs

  4. Neutron spectrum unfolding using neural networks

    International Nuclear Information System (INIS)

    Vega C, H.R.; Hernandez D, V.M.; Manzanares A, E.

    2004-01-01

    An artificial neural network has been designed to obtain the neutron spectra from the Bonner spheres spectrometer's count rates. The neural network was trained using a large set of neutron spectra compiled by the International Atomic Energy Agency. These include spectra from iso- topic neutron sources, reference and operational neutron spectra obtained from accelerators and nuclear reactors. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra and UTA4 matrix were used to calculate the expected count rates in Bonner spheres spectrometer. These count rates were used as input and correspondent spectrum was used as output during neural network training. The network has 7 input nodes, 56 neurons as hidden layer and 31 neurons in the output layer. After training the network was tested with the Bonner spheres count rates produced by twelve neutron spectra. The network allows unfolding the neutron spectrum from count rates measured with Bonner spheres. Good results are obtained when testing count rates belong to neutron spectra used during training, acceptable results are obtained for count rates obtained from actual neutron fields; however the network fails when count rates belong to monoenergetic neutron sources. (Author)

  5. In Situ Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The In Situ Mass Spectrometer projects focuses on a specific subsystem to leverage advanced research for laser-based in situ mass spectrometer development...

  6. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  7. Small-angle neutron-scattering experiments

    International Nuclear Information System (INIS)

    Hardy, A.D.; Thomas, M.W.; Rouse, K.D.

    1981-04-01

    A brief introduction to the technique of small-angle neutron scattering is given. The layout and operation of the small-angle scattering spectrometer, mounted on the AERE PLUTO reactor, is also described. Results obtained using the spectrometer are presented for three materials (doped uranium dioxide, Magnox cladding and nitrided steel) of interest to Springfields Nuclear Power Development Laboratories. The results obtained are discussed in relation to other known data for these materials. (author)

  8. Characterization of MEMS FTIR spectrometer

    Science.gov (United States)

    Khalil, Diaa; Sabry, Yasser; Omran, Haitham; Medhat, Mostafa; Hafez, Amr; Saadany, Bassam

    2011-03-01

    In this work we present the full characterization of an optical MEMS Fourier Transform Infra Red FTIR spectrometer fabricated by Deep Reactive Ion Etching DRIE Technology on Silicon substrate. Both electrical and optical properties of the spectrometer are measured. The presented techniques allows to build an engineering model for the spectrometer and to predict its main specifications taking into account the specificity of the MEMS technology used in the spectrometer fabrication.

  9. Small angle neutron scattering

    Directory of Open Access Journals (Sweden)

    Cousin Fabrice

    2015-01-01

    Full Text Available Small Angle Neutron Scattering (SANS is a technique that enables to probe the 3-D structure of materials on a typical size range lying from ∼ 1 nm up to ∼ a few 100 nm, the obtained information being statistically averaged on a sample whose volume is ∼ 1 cm3. This very rich technique enables to make a full structural characterization of a given object of nanometric dimensions (radius of gyration, shape, volume or mass, fractal dimension, specific area… through the determination of the form factor as well as the determination of the way objects are organized within in a continuous media, and therefore to describe interactions between them, through the determination of the structure factor. The specific properties of neutrons (possibility of tuning the scattering intensity by using the isotopic substitution, sensitivity to magnetism, negligible absorption, low energy of the incident neutrons make it particularly interesting in the fields of soft matter, biophysics, magnetic materials and metallurgy. In particular, the contrast variation methods allow to extract some informations that cannot be obtained by any other experimental techniques. This course is divided in two parts. The first one is devoted to the description of the principle of SANS: basics (formalism, coherent scattering/incoherent scattering, notion of elementary scatterer, form factor analysis (I(q→0, Guinier regime, intermediate regime, Porod regime, polydisperse system, structure factor analysis (2nd Virial coefficient, integral equations, characterization of aggregates, and contrast variation methods (how to create contrast in an homogeneous system, matching in ternary systems, extrapolation to zero concentration, Zero Averaged Contrast. It is illustrated by some representative examples. The second one describes the experimental aspects of SANS to guide user in its future experiments: description of SANS spectrometer, resolution of the spectrometer, optimization of

  10. Inelastic neutron scattering for electronic properties at MLF/J-PARC

    International Nuclear Information System (INIS)

    Nakajima, K.

    2016-01-01

    At our spallation neutron source of Materials and Life Science Experimental Facility in JPARC, six inelastic instruments are working or under construction. These are four chopper spectrometers, a high-intensity Fermi-chopper spectrometer 4EASONS (BL01), a high-resolution Fermi-chopper spectrometer HRC (BL12), a cold-neutron disk-chopper spectrometer AMATERAS (BL14) and a polarized neutron dedicated chopper spectrometer POLANO (BL23, under construction), one near-back scattering crystal analyzer spectrometer DNA (BL02) and one spin-echo suite (a combination of MIEZE and NRSE spin-echo instruments), VIN ROSE (BL06). All of these instruments are world-leading neutron spectrometers at a pulsed neutron source, in which we have devoted state-of-art techniques and devices to enhance research out-puts from them. Our spectrometers have been providing unique research opportunities in the broad range of scientific fields including studying dynamics of magnetic and structural properties in solids. In this presentation, with brief overview of our spectrometers and possible scientific opportunities given by them, I will review out comes recently obtained from our inelastic neutron scattering studies investigating electronic properties in materials. (author)

  11. Neutron spectrometry with organic scintillation detector

    International Nuclear Information System (INIS)

    Butragueno Casado, J. L.

    1972-01-01

    This work describes a fast neutron spectrometer using a stilbene crystal as head detector with pulse shape discrimination (P.S.D.) to reject gamma background. Tre experimental procedure involves the P.S.D., the measurements to calibrate the spectrometer and the corrections for several factors, mainly the non-linear response of the stilbene. Results of the measurements with the reaction D 2 (d,n)He 3 , and with an Am-Be neutron source are presented. It is also presented the measurement of the spectrum of the fast reactor CCRAl-1. (Author) 17 refs

  12. HELIOS: A high intensity chopper spectrometer at LANSCE

    Energy Technology Data Exchange (ETDEWEB)

    Mason, T.E. [Oak Ridge National Lab., TN (United States); Broholm, C. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Physics and Astronomy; Fultz, B. [California Inst. of Tech., Pasadena, CA (United States). Dept. of Materials Science] [and others

    1998-12-31

    A proposal to construct a high intensity chopper spectrometer at LANSCE as part of the SPSS upgrade project is discussed. HELIOS will be optimized for science requiring high sensitivity neutron spectroscopy. This includes studies of phonon density of states in small polycrystalline samples, magnetic excitations in quantum magnets and highly correlated electron systems, as well as parametric studies (as a function of pressure, temperature, or magnetic field) of S(Q,{omega}). By employing a compact design together with the use of supermirror guide in the incident flight path the neutron flux at HELIOS will be significantly higher than any other comparable instrument now operating.

  13. HELIOS: A high intensity chopper spectrometer at LANSCE

    International Nuclear Information System (INIS)

    Mason, T.E.; Broholm, C.; Fultz, B.

    1998-01-01

    A proposal to construct a high intensity chopper spectrometer at LANSCE as part of the SPSS upgrade project is discussed. HELIOS will be optimized for science requiring high sensitivity neutron spectroscopy. This includes studies of phonon density of states in small polycrystalline samples, magnetic excitations in quantum magnets and highly correlated electron systems, as well as parametric studies (as a function of pressure, temperature, or magnetic field) of S(Q,ω). By employing a compact design together with the use of supermirror guide in the incident flight path the neutron flux at HELIOS will be significantly higher than any other comparable instrument now operating

  14. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  15. Mark III spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.; Bernstein, J.; Bunnell, K.; Burgueno, G.; Cassell, R.; Collins, B.; Coward, D.; Einsweiler, K.; Eisele, R.; Haber, B.

    1984-10-01

    This paper describes the design, construction and performance of the Mark III, a new general purpose large solid angle spectrometer at SPEAR, the SLAC 2-8 GeV e/sup +/e storage ring. The detector has been designed for the study of exclusive final states in e/sup +/e annihilation, which requires large solid angle coverage combined with charged particle momentum resolution, particle identification, and photon detection efficiency at low energies. (orig.).

  16. Mark III spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.; Bernstein, J.; Bunnell, K.; Burgueno, G.; Cassell, R.; Collins, B.; Coward, D.; Einsweiler, K.; Eisele, R.; Haber, B. (Stanford Linear Accelerator Center, CA (USA))

    1984-10-01

    This paper describes the design, construction and performance of the Mark III, a new general purpose large solid angle spectrometer at SPEAR, the SLAC 2-8 GeV e/sup +/e/sup -/ storage ring. The detector has been designed for the study of exclusive final states in e/sup +/e/sup -/ annihilation, which requires large solid angle coverage combined with charged particle momentum resolution, particle identification, and photon detection efficiency at low energies.

  17. Magnetic spectrometer control system

    International Nuclear Information System (INIS)

    Lecca, L.A.; Di Paolo, Hugo; Fernandez Niello, Jorge O.; Marti, Guillermo V; Pacheco, Alberto J.; Ramirez, Marcelo

    2003-01-01

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  18. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  19. Miniaturized Ion Mobility Spectrometer

    Science.gov (United States)

    Kaye, William J (Inventor); Stimac, Robert M. (Inventor)

    2017-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer (IMS) achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250 degrees Centigrade, and is uniquely sensitive, particularly to explosive chemicals.

  20. Theory and optical design of x-ray echo spectrometers

    Science.gov (United States)

    Shvyd'ko, Yuri

    2017-08-01

    X-ray echo spectroscopy, a space-domain counterpart of neutron spin echo, is a recently proposed inelastic x-ray scattering (IXS) technique. X-ray echo spectroscopy relies on imaging IXS spectra and does not require x-ray monochromatization. Due to this, the echo-type IXS spectrometers are broadband, and thus have a potential to simultaneously provide dramatically increased signal strength, reduced measurement times, and higher resolution compared to the traditional narrow-band scanning-type IXS spectrometers. The theory of x-ray echo spectrometers presented earlier [Yu. Shvyd'ko, Phys. Rev. Lett. 116, 080801 (2016), 10.1103/PhysRevLett.116.080801] is developed here further with a focus on questions of practical importance, which could facilitate optical design and assessment of the feasibility and performance of the echo spectrometers. Among others, the following questions are addressed: spectral resolution, refocusing condition, echo spectrometer tolerances, refocusing condition adjustment, effective beam size on the sample, spectral window of imaging and scanning range, impact of the secondary source size on the spectral resolution, angular dispersive optics, focusing and collimating optics, and detector's spatial resolution. Examples of optical designs and characteristics of echo spectrometers with 1-meV and 0.1-meV resolutions are presented.

  1. Construction of Ge(Li)-NaI(Tl) pair spectrometer

    International Nuclear Information System (INIS)

    Hassan, A.M.; El-Kady, A.A.; Eissa, E.A.; Rofail, N.B.; Abu-Zeid, H.M.; Hamouda, I.

    1978-01-01

    The details of the construction and tests of the Ge (li)-NaI (Tl) pair spectrometer has been presented. The spectrometer was set up at one of the horizontal channels of the ET-RR-1 research reactor using a true coaxial Ge (li) detector of sensitive volume 30 cm 3 surrounded by an 8''L. x8''0annulus NaI (Tl) crystal. The coincidence technique is carried out between the central Ge (Li) detector and the surrounding NaI (Tl) detector to detect the annihilation quanta. The operating conditions and the preliminary experimental results were obtained using the gamma-ray spectra of 24 Na and ThC'' as radioactive sources. The high energy part of the gamma-ray spectrum following the thermal neutron capture in 35 Cl is taken, as check for the validity of the spectrometer. By the method used at energies above 2 Mev, the Compton background of Ge (Li) detector system is reduced, and the gamma ray energy gives only one peak in the pulse height distribution curve. The spectrometer gives slightly superior resolution compared to the single spectrometer and is capable of determining the energies of capture gamma rays (with well defined spectral peaks) to an accuracy of 1 kev. The spectrometer is very useful for resolving closely spaced lines and for observation of weak lines near the high energy and of gamma-ray spectrum and many weak intensity gamma-ray can be studied

  2. Development of a bandwidth limiting neutron chopper for CSNS

    Science.gov (United States)

    Wang, P.; Yang, B.; Cai, W. L.

    2015-08-01

    Bandwidth limiting neutron choppers are indispensable key equipments for the time-of-flight neutron scattering spectrometers of China Spallation Neutron Source (CSNS). The main principle is to chop the neutron beam to limit the neutron wavelength bandwidth at the neutron detector. We have successfully developed a bandwidth limiting neutron chopper for CSNS in the CSNS advance research project II. The transmission rate of the neutron absorbing coating is less than 1×10-4 (for 1 angstrom neutron). The phase control accuracy is ±0.084° (±9.4 μs at 25 Hz). The dynamic balance grade is G1.0. Various experimental technical features have met the design requirements, and it also runs stably and reliably during the long-term tests.

  3. Development of a bandwidth limiting neutron chopper for CSNS

    International Nuclear Information System (INIS)

    Wang, P.; Yang, B.; Cai, W.L.

    2015-01-01

    Bandwidth limiting neutron choppers are indispensable key equipments for the time-of-flight neutron scattering spectrometers of China Spallation Neutron Source (CSNS). The main principle is to chop the neutron beam to limit the neutron wavelength bandwidth at the neutron detector. We have successfully developed a bandwidth limiting neutron chopper for CSNS in the CSNS advance research project II. The transmission rate of the neutron absorbing coating is less than 1×10 −4 (for 1 angstrom neutron). The phase control accuracy is ±0.084° (±9.4 μs at 25 Hz). The dynamic balance grade is G1.0. Various experimental technical features have met the design requirements, and it also runs stably and reliably during the long-term tests

  4. Neutron activation system for spectral measurements of pulsed ion diode neutron production

    International Nuclear Information System (INIS)

    Hanson, D.L.; Kruse, L.W.

    1980-02-01

    A neutron energy spectrometer has been developed to study intense ion beam-target interactions in the harsh radiation environment of a relativistic electron beam source. The main component is a neutron threshold activation system employing two multiplexed high efficiency Ge(Li) detectors, an annihilation gamma coincidence system, and a pneumatic sample transport. Additional constraints on the neutron spectrum are provided by total neutron yield and time-of-flight measurements. A practical lower limit on the total neutron yield into 4π required for a spectral measurement with this system is approx. 10 10 n where the neutron yield is predominantly below 4 MeV and approx. 10 8 n when a significant fraction of the yield is above 4 MeV. Applications of this system to pulsed ion diode neutron production experiments on Hermes II are described

  5. A spectrometer for the NSF

    International Nuclear Information System (INIS)

    Sanderson, N.E.

    1979-01-01

    It is shown that the capabilities of a magnetic spectrometer are needed to fully exploit the research programme involving charged particle detection to be carried out on the Nuclear Structure Facility (NSF) presently under construction at Daresbury. Performance requirements for such a spectrometer are examined indicating that the QMG/2 spectrometer of the Groningen type is very well suited to the high resolution work which will be possible using beams of light - heavy ions (A < 40). Consequently, and following the recommendations of the Magnetic Spectrometer Working Party, this spectrometer is to be installed at the NSF. (U.K.)

  6. aCORN Beta Spectrometer and Electrostatic Mirror

    Science.gov (United States)

    Hassan, Md; aCORN Collaboration

    2013-10-01

    aCORN uses a high efficiency backscatter suppressed beta spectrometer to measure the electron-antineutrino correlation in neutron beta decay. We measure the correlation by counting protons and beta electrons in coincidence with precisely determined electron energy. There are 19 photomultiplier tubes arranged in a hexagonal array coupled to a single phosphor doped polystyrene scintillator. The magnetic field is shaped so that electrons that backscatter without depositing their full energy strike a tulip-shaped array of scintillator paddles and these events are vetoed. The detailed construction, performance and calibration of this beta spectrometer will be presented. I will also present the simulation, construction, and features of our novel electrostatic mirror. This work was supported by the National Science Foundation and the NIST Center for Neutron Research.

  7. Neutron fluence spectrometry using disk activation

    International Nuclear Information System (INIS)

    Loevestam, Goeran; Hult, Mikael; Fessler, Andreas; Gasparro, Joel; Kockerols, Pierre; Okkinga, Klaas; Tagziria, Hamid; Vanhavere, Filip; Wieslander, J.S. Elisabeth

    2009-01-01

    A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000-10000 cm -2 s -1 , where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also been tested using an AmBe source and at a neutron fluence rate of about 40 cm -2 s -1 , again, a good agreement with the assumed spectrum was achieved

  8. Neutron fluence spectrometry using disk activation

    Energy Technology Data Exchange (ETDEWEB)

    Loevestam, Goeran [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium)], E-mail: goeran.loevestam@ec.europa.eu; Hult, Mikael; Fessler, Andreas; Gasparro, Joel; Kockerols, Pierre; Okkinga, Klaas [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Tagziria, Hamid [EC-JRC-Institute for the Protection and the Security of the Citizen (IPSC), Via E. Fermi 1, I-21020 Ispra (Vatican City State, Holy See,) (Italy); Vanhavere, Filip [SCK-CEN, Boeretang, 2400 Mol (Belgium); Wieslander, J.S. Elisabeth [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Department of Physics, P.O. Box 35 (YFL), FIN-40014, University of Jyvaeskylae (Finland)

    2009-01-15

    A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000-10000 cm{sup -2} s{sup -1}, where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also been tested using an AmBe source and at a neutron fluence rate of about 40 cm{sup -2} s{sup -1}, again, a good agreement with the assumed spectrum was achieved.

  9. Neutron spectrometry measurements in iron

    International Nuclear Information System (INIS)

    Perlini, G.; Acerbis, S.; Carter, M.

    1988-01-01

    A compact structure was prepared for use in making measurements of neutron penetration in iron which could serve as reference data and as a check for computer codes. About 30 iron plates were put together giving a useful overall length of 130 cm. At various depths along the central axis of the iron block, measurements were made with liquid scintillator spectrometers and proton recoil proportional counters. The energy band explored was between 14 KeV and 10 MeV. Here we report the original spectra of the impulses and the neutron spectra found by the NE213 code based on the differential method and by unfolding with the SPEC4 code for liquid scintillation counters and proton recoil spectrometers, respectively. 12 figs., 60 tabs., 6 refs

  10. Technical description of the Tansy Spectrometer, TANSY-KM5

    International Nuclear Information System (INIS)

    Grosshoeg, G.; Aronsson, D.; Hoek, M.; Rydz, R.; Norberg, L.; Urholm, L.

    1991-07-01

    The TANSY-KM5 neutron spectrometer is a system containing a lot of advanced electronic and mechanical components. The design of the system has been reported in two documents (CTH-RF--54 (INIS 17:10206) and CTH-RF--43 (INIS 14:797424)). The purpose of this documentation is to give a brief overview of the system as it is defined at the time of delivery

  11. Neutron scattering. Annual progress report 1997

    International Nuclear Information System (INIS)

    Allenspach, P.; Boeni, B.; Fischer, P.; Furrer, A.

    1998-02-01

    The present progress report describes the scientific and technical activities obtained by LNS staff members in 1997. It also includes the work performed by external groups at our CRG instruments D1A and IN3 at the ILL Grenoble. Due to the outstanding properties of neutrons and x-rays the research work covered many areas of science and materials research. The highlight of the year 1997 was certainly the production of neutrons at the new spallation neutron source SINQ. From July to November, SINQ was operating for typically two days/week and allowed the commissioning of four instruments at the neutron guide system: - the triple-axis spectrometer Druechal, - the powder diffractometer DMC, - the double-axis diffractometer TOPSI, the polarised triple-axis spectrometer TASP. These instruments are now fully operational and have already been used for condensed matter studies, partly in cooperation with external groups. Five further instruments are in an advanced state, and their commissioning is expected to occur between June and October 1998: - the high-resolution powder diffractometer HRPT, - the single-crystal diffractometer TriCS, - the time-of-flight spectrometer FOCUS, - the reflectometer AMOR, - the neutron optical bench NOB. Together with the small angle neutron scattering facility SANS operated by the spallation source department, all these instruments will be made available to external user groups in the future. (author) figs., tabs., refs

  12. BATS - Backscattering And Time-of-flight Spectrometer

    International Nuclear Information System (INIS)

    Van Eijck, L.; Seydel, T.; Frick, B.; Schober, H.

    2011-01-01

    The new backscattering spectrometer IN16b will go into commissioning end 2011, providing in its final state about ten times higher count rate than its predecessor, IN16. Here we propose to increase its dynamic range by a factor of 7 with the TOF mode extension, BATS. This will make IN16b the leading high resolution backscattering spectrometer for incoherent quasi-elastic and inelastic neutron scattering; it will be competitive to the coarser resolution inverted geometry backscattering spectrometers that are being brought online at spallation sources. The increased dynamic range will extend the scope of science addressed on IN16b, generating considerable potential in fields such as the hydrogen economy (proton conduction, fuel cells, hydrogen storage), soft matter, biology and nano-science (nano-scale confinement, functionalized polymers). Such a large impact can be achieved using only a moderate investment. (authors)

  13. Design of magnetic analysis system for magnetic proton recoil spectrometer

    International Nuclear Information System (INIS)

    Qi Jianmin; Jiang Shilun; Zhou Lin; Peng Taiping

    2010-01-01

    Magnetic proton recoil (MPR) spectrometer is a novel diagnostic instrument with high performance for measurements of the neutron spectra from inertial confinement fusion (ICF) experiments and high power fusion devices. The design of the magnetic analysis system, which is a key part of the compact MPR-type spectrometer, has been completed through two-dimensional beam transport simulations and three-dimensional particle transport simulation. The analysis of the system's parameters and performances was performed, as well as system designs based on preferential principles of energy resolution, detection efficiency, and count rate, respectively. The results indicate that the magnetic analysis system can achieve a detection efficiency of 10 -5 ∼ 10 -4 level at the resolution range of 1.5% to 3.0% and fulfill the design goals of the compact MPR spectrometer. (authors)

  14. Calibration issues for neutron diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sadler, G.J. [JET Joint Undertaking, Abingdon (United Kingdom); Adams, J.M. [AEA Technology, Harwell (United Kingdom); Barnes, C.W. [Los Alamos National Lab., NM (United States)] [and others

    1997-12-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next.

  15. Prospects for the use of the pulsed fields in neutron research of condensed matter

    CERN Document Server

    Nietz, V

    2003-01-01

    The peculiarities of the pulsed magnetic field usage in the research of magnetic properties of crystal substances with different pulsed and steady-state sources of neutrons are considered. The comparative characteristics of existing and some projected spectrometers intended for neutron researches are evaluated. The comparison of the efficiency of experiments on the most intensive neutron sources is discussed.

  16. Neutron-scattering study of the vibrational behavior of trehalose aqueous solutions

    CERN Document Server

    Branca, C; Migliardo, F; Romeo, G; Villari, V; Wanderlingh, U; Colognesi, D

    2002-01-01

    Neutron spectra for hydrated trehalose samples have been obtained by using the time-of-flight spectrometer TOSCA at the ISIS Pulse Neutron Facility (Rutherford Appleton Laboratory, Chilton, UK). Neutron spectra have been compared to the absorbance spectra obtained by Fourier-transform infrared spectroscopy. Finally, a comparison with findings obtained by density functional theory has been performed. 3 Refs.

  17. Global Maps of Lunar Neutron Fluxes from the LEND Instrument

    Science.gov (United States)

    Litvak, M. L.; Mitrofanov, I. G.; Sanin, A.; Malakhov, A.; Boynton, W. V.; Chin, G.; Droege, G.; Evans, L. G.; Garvin, J.; Golovin, D. V.; hide

    2012-01-01

    The latest neutron spectrometer measurements with the Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) are presented. It covers more than 1 year of mapping phase starting on 15 September 2009. In our analyses we have created global maps showing regional variations in the flux of thermal (energy range neutrons (>0.5 MeV), and compared these fluxes to variances in soil elemental composition, and with previous results obtained by the Lunar Prospector Neutron Spectrometer (LPNS). We also processed data from LEND collimated detectors and derived a value for the collimated signal of epithermal neutrons based on the comparative analysis with the LEND omnidirectional detectors. Finally, we have compared our final (after the data reduction) global epithermal neutron map with LPNS data.

  18. On the use of the cold time-of-flight spectrometer in Studsvik for liquid 3He measurements

    International Nuclear Information System (INIS)

    Faak, Bjoern.

    1989-01-01

    The time-of-flight spectrometer for cold neutrons at the R2 reactor in Studsvik has been reconstructed. The design and the performance of the instrument are briefly described. Improvements required for measurement of the neutron scattering function of liquid 3 He are discussed. (author)

  19. Characterisation of the IPNE Bonner sphere spectrometer by comparison with the PTB system

    CERN Document Server

    Alevra, A V

    2002-01-01

    An existing set of Bonner spheres of the Institute for Physics and Nuclear Engineering in Bucharest has been modified following the PTB design for application of an sup 3 He-filled SP9 counter. By simple interpolations of the fluence responses of the PTB spheres, a preliminary fluence response matrix could be established for the IPNE Bonner sphere set. For further adjustments of the preliminary responses and for validation of the final fluence response matrix of the Romanian Bonner sphere spectrometer, calibration measurements with a reference sup 2 sup 5 sup 2 Cf neutron source and joint measurements, including the PTB Bonner sphere spectrometer, were performed in a few neutron fields differing substantially in their spectral distributions. It is estimated that the integral neutron fluences and dose-equivalent values can now be determined with the Romanian spectrometer with uncertainties of about +-4% and +-8%, respectively.

  20. Neutron guide

    Science.gov (United States)

    Greene, Geoffrey L.

    1999-01-01

    A neutron guide in which lengths of cylindrical glass tubing have rectangular glass plates properly dimensioned to allow insertion into the cylindrical glass tubing so that a sealed geometrically precise polygonal cross-section is formed in the cylindrical glass tubing. The neutron guide provides easier alignment between adjacent sections than do the neutron guides of the prior art.

  1. Effect of the size of experimental channels of the lead slowing-down spectrometer SVZ-100 (Institute for Nuclear Research, Moscow) on the moderation constant

    International Nuclear Information System (INIS)

    Latysheva, L. N.; Bergman, A. A.; Sobolevsky, N. M.; Ilić, R. D.

    2013-01-01

    Lead slowing-down (LSD) spectrometers have a low energy resolution (about 30%), but their luminosity is 10 3 to 10 4 times higher than that of time-of-flight (TOF) spectrometers. A high luminosity of LSD spectrometers makes it possible to use them to measure neutron cross section for samples of mass about several micrograms. These features specify a niche for the application of LSD spectrometers in measuring neutron cross sections for elements hardly available in macroscopic amounts—in particular, for actinides. A mathematical simulation of the parameters of SVZ-100 LSD spectrometer of the Institute for Nuclear Research (INR, Moscow) is performed in the present study on the basis of the MCNPX code. It is found that the moderation constant, which is the main parameter of LSD spectrometers, is highly sensitive to the size and shape of detecting volumes in calculations and, hence, to the real size of experimental channels of the LSD spectrometer.

  2. Current Status and Future Works of Neutron Scattering Laboratory at BATAN in Serpong

    International Nuclear Information System (INIS)

    Ikram, A.

    2008-01-01

    Current status of neutron beam instruments using neutrons produced by the Multi Purpose Research Reactor--30MWth (MPR 30, RSG GA Siwabessy) located in Serpong is presented. Description of the reactor as the neutron source is mentioned briefly. There are six neutron beam tubes coming from the beryllium reflector surrounding half of the reactor core providing neutrons in the experimental hall of the reactor (XHR). Four of them are dedicated to R and D in materials science using neutron scattering techniques. Neutron Radiography Facility (NRF), Triple Axis Spectrometer (TAS) and Residual Stress Measurement (RSM) Diffractometer are installed respectively at beam tubes S2, S4 and S6. The largest neutron beam tube (S5) is exploited to accommodate two neutron guide tubes that transfer the neutrons to a neighbouring building called neutron guide hall (NGH). There are three other neutron beam instruments installed in this building, namely Small Angle Neutron Scattering (SANS) Spectrometer (SMARTer), High Resolution SANS (HRSANS) Spectrometer and High Resolution Powder Diffractometer (HRPD). In the XHR, a Four Circle and Texture Diffractometer (FCD/TD) is attached to one of the neutron guide tubes. These seven instruments were installed to utilize the neutrons for materials science research, and recently the RSM diffractometer has shown its capabilities in identifying different amount of stress left due to different treatments of welding in fuel cladding, while the SANS spectrometer is now gaining capabilities in identifying different sizes and shapes of macromolecules in polymers as well as investigations of magnetic samples. In the mean time, non-destructive tests using the NRF is gathering more confidence from some latest real time measurements eventhough there are still some shortcomings in the components and their alignments. Future works including improvement of each facility and its components, even replacement of some parts are necessary and have to be carried out

  3. MASS SPECTROMETER LEAK

    Science.gov (United States)

    Shields, W.R.

    1960-10-18

    An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.

  4. Neutron spectrometry and dosimetry in the environment and at workplaces

    International Nuclear Information System (INIS)

    Alevra, A.V.; Klein, H.; Knauf, K.; Wittstock, J.; Wolber, G.

    1998-01-01

    Results obtained in diverse environments (including workplaces) using both spectrometric and dosimetric instrumentation were compared. The following topics are included: PTB Bonner sphere spectrometers; natural cosmic ray-induced neutron background; neutron fields at the Dukovany nuclear power plant (Czech Republic); neutron fields at the isochronous cyclotron of the German Cancer Research center in Heidelberg; and accuracy of the integral results obtained with Bonner spheres. (P.A.)

  5. Current status of some neutron instruments in Serpong

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, A.; Hardi, T.; Maulana, A. [Neutron Scattering Lab., Materials Science Research Center, BATAN-Serpong, Jakarta (Indonesia)

    1998-10-01

    Performances of the Small Angle Neutron Scattering Spectrometer, the High Resolution Small Angle Neutron Scattering Spectrometer and the High Resolution Neutron Powder Diffractometer in the last full one year are presented as well as problems, difficulties and limitations faced by each instrument. Efforts that have been done to overcome those shortcomings are also mentioned. Proposed collaboration in order to bring those instruments back to a state that can perform scientifically acceptable is described to a level that can be agreed in this workshop. (author)

  6. The SPEDE electron spectrometer

    CERN Document Server

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  7. Polarisation analysis on the LET time-of-flight spectrometer

    Science.gov (United States)

    Nilsen, G. J.; Košata, J.; Devonport, M.; Galsworthy, P.; Bewley, R. I.; Voneshen, D. J.; Dalgliesh, R.; Stewart, J. R.

    2017-06-01

    We present a design for implementing uniaxial polarisation analysis on the LET cold neutron time-of-flight spectrometer, installed on the second target station at ISIS. The polarised neutron beam is to be produced by a transmission-based supermirror polariser with the polarising mirrors arranged in a “double-V” formation. This will be followed by a Mezei-type precession coil spin flipper, selected for its small spatial requirements, as well as a permanent magnet guide field to transport the beam polarisation to the sample position. The sample area will contain a set of holding field coils, whose purpose is to produce a highly homogenous magnetic field for the wide-angle 3He analyser cell. To facilitate fast cell changes and reduce the risk of cell failure, we intend to separate the cell and cryostat from the vacuum of the sample tank by installing both in a vessel at atmospheric pressure. When the instrument upgrade is complete, the performance of LET is expected to be commensurate with existing and planned polarised cold neutron spectrometers at other sources. Finally, we discuss the implications of performing uniaxial polarisation analysis only, and identify quasi-elastic neutron scattering (QENS) on ionic conducting materials as an interesting area to apply the technique.

  8. Neutron physics

    CERN Document Server

    Reuss, Paul

    2008-01-01

    Originally just an offshoot of nuclear physics, neutron physics soon became a branch of physics in its own right. It deals with the movement of neutrons in nuclear reactors and ail the nuclear reactions they trigger there, particularly the fission of heavy nuclei which starts a chain reaction to produce energy. Neutron Physics covers the whole range of knowledge of this complex science, discussing the basics of neutron physics and some principles of neutron physics calculations. Because neutron physics is the essential part of reactor physics, it is the main subject taught to students of Nuclear Engineering. This book takes an instructional approach for that purpose. Neutron Physics is also intended for ail physicists and engineers involved in development or operational aspects of nuclear power.

  9. LADEE Neutral Mass Spectrometer Data

    Data.gov (United States)

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  10. Conceptual design of neutron diagnostic systems for fusion experimental reactor

    International Nuclear Information System (INIS)

    Iguchi, T.; Kaneko, J.; Nakazawa, M.

    1994-01-01

    Neutron measurement in fusion experimental reactors is very important for burning plasma diagnostics and control, monitoring of irradiation effects on device components, neutron source characterization for in-situ engineering tests, etc. A conceptual design of neutron diagnostic systems for an ITER-like fusion experimental reactor has been made, which consists of a neutron yield monitor, a neutron emission profile monitor and a 14-MeV spectrometer. Each of them is based on a unique idea to meet the required performances for full power conditions assumed at ITER operation. Micro-fission chambers of 235 U (and 238 U) placed at several poloidal angles near the first wall are adopted as a promising neutron yield monitor. A collimated long counter system using a 235 U fission chamber and graphite neutron moderators is also proposed to improve the calibration accuracy of absolute neutron yield determination

  11. Experiments with neutron-rich isomeric beams

    International Nuclear Information System (INIS)

    Rykaczewski, K.; Lewitowicz, M.; Pfuetzner, M.

    1998-01-01

    A review of experimental results obtained on microsecond-isomeric states in neutron-rich nuclei produced in fragmentation reactions and studied with SISSI-Alpha-LISE3 spectrometer system at GANIL Caen is given. The perspectives of experiments based on secondary reactions with isomeric beams are presented

  12. Use of cold neutrons for condensed matter research at the neutron guide laboratory ELLA in Juelich

    International Nuclear Information System (INIS)

    Schaetzler, R.; Monkenbusch, M.

    1998-01-01

    Cold neutrons produced in the FRJ-2 DIDO reactor are guided into the external hall ELLA. It hosts 10 instruments that are red by three major neutron guides. Cold neutrons allow for diffraction and small angle scattering experiments resolving mesoscopic structures (1 to 100 nm). Contrast variation by isotopic substitution in chemically identical species yields information uniquely accessible bi neutrons. Inelastic scattering of cold neutrons allows investigating slow molecular motions because the low neutron velocity results in large relative velocity changes even at small energy transfers. The SANS machines and the HADAS reflectometer serve as structure probes and the backscattering BSS1 and spin-echo spectrometers NSE as main dynamics probes. Besides this the diffuse scattering instrument DNS and the lattice parameter determination instrument LAP deal mainly with crystals and their defects. Finally the beta-NMR and the EKN position allow for methods other than scattering employing nuclear reactions for solid state physics, chemistry and biology/medicine. (author)

  13. Local tracking in the ATLAS muon spectrometer

    CERN Document Server

    Primor, David; Mikenberg, Giora

    2007-01-01

    The LHC, the largest hadron collider accelerator ever built, presents new challenges for scientists and engineers. With the anticipated luminosity of the LHC, it is expected to have as many as one billion total collisions per second, of which at most 10 to 100 per second might be of potential scientific interest. One of the two major, general-purpose experiments at LHC is called ATLAS. Since muons are one of the important signs of new physics, the need of their detection has lead to the construction of a stand- alone Muon Spectrometer. This system is located in a high radiation background environment (mostly neutrons and photons) which makes the muon tracking a very challenging task. The Muon Spectrometer consists of two types of precision chambers, the Monitor Drift Tube (MDT) chambers, and the Cathode Strip Chambers (CSC). In order to detect the muon and estimate its track parameters, it is very important to detect and precisely estimate its local tracks within the CSC and MDT chambers. Using advanced signa...

  14. The secondary neutrons spectra of 235U, 238U for incident energy range 1-2.5 MeV

    International Nuclear Information System (INIS)

    Kornilov, N.V.; Kagalenko, A.B.; Balitsky, A.V.; Baryba, V.Ja.; Androsenko, P.A.; Androsenko, A.A.

    1993-01-01

    Spectra of inelastic scattered neutrons and fission neutrons were measured with neutron time of flight spectrometer. The solid tritium target was used as a neutron source. The energy distribution of neutrons on the sample was calculated with Monte-Carlo code, taking into account interaction income protons inside target and reaction kinematics. The detector efficiency was determined with 252 Cf source. The multiple scattering and absorption corrections were calculated with codes packet BRAND. Our results confirm ENDF/B-6 data library. (author)

  15. Neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi

    1988-01-01

    The thermal neutron absorption coefficient is essentially different from the X-ray absorption coefficient. Each substance has a characteristic absorption coefficient regardless of its density. Neutron deams have the following features: (1) neutrons are not transmitted efficiently by low molecular weight substances, (2) they are transmitted efficiently by heavy metals, and (3) the transmittance differs among isotopes. Thus, neutron beams are suitable for cheking for foreign matters in heavy metals and testing of composites consisting of both heavy and light materials. A neutron source generates fast neutrons, which should be converted into thermal neutrons by reducing their energy. Major neutron souces include nuclear reactors, radioisotopes and particle accelerators. Photographic films and television systems are mainly used to observe neutron transmission images. Computers are employed for image processing, computerized tomography and three-dimensional analysis. The major applications of neutron radiography include inspection of neclear fuel; evaluation of material for airplane; observation of fuel in the engine and oil in the hydraulic systems in airplanes; testing of composite materials; etc. (Nogami, K.)

  16. The nanopore mass spectrometer

    Science.gov (United States)

    Bush, Joseph; Maulbetsch, William; Lepoitevin, Mathilde; Wiener, Benjamin; Mihovilovic Skanata, Mirna; Moon, Wooyoung; Pruitt, Cole; Stein, Derek

    2017-11-01

    We report the design of a mass spectrometer featuring an ion source that delivers ions directly into high vacuum from liquid inside a capillary with a sub-micrometer-diameter tip. The surface tension of water and formamide is sufficient to maintain a stable interface with high vacuum at the tip, and the gas load from the interface is negligible, even during electrospray. These conditions lifted the usual requirement of a differentially pumped system. The absence of a background gas also opened up the possibility of designing ion optics to collect and focus ions in order to achieve high overall transmission and detection efficiencies. We describe the operation and performance of the instrument and present mass spectra from solutions of salt ions and DNA bases in formamide and salt ions in water. The spectra show singly charged solute ions clustered with a small number of solvent molecules.

  17. BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    Saulys, A.C.

    1984-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  18. A Moessbauer effect spectrometer

    International Nuclear Information System (INIS)

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  19. Photo ion spectrometer

    Science.gov (United States)

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A charged particle spectrometer for performing ultrasensitive quantitative analysis of selected atomic components removed from a sample. Significant improvements in performing energy and angular refocusing spectroscopy are accomplished by means of a two dimensional structure for generating predetermined electromagnetic field boundary conditions. Both resonance and non-resonance ionization of selected neutral atomic components allow accumulation of increased chemical information. A multiplexed operation between a SIMS mode and a neutral atomic component ionization mode with EARTOF analysis enables comparison of chemical information from secondary ions and neutral atomic components removed from the sample. An electronic system is described for switching high level signals, such as SIMS signals, directly to a transient recorder and through a charge amplifier to the transient recorder for a low level signal pulse counting mode, such as for a neutral atomic component ionization mode.

  20. Monte-Carlo simulation of a high-resolution inverse geometry spectrometer on the SNS. Long Wavelength Target Station

    International Nuclear Information System (INIS)

    Bordallo, H.N.; Herwig, K.W.

    2001-01-01

    Using the Monte-Carlo simulation program McStas, we present the design principles of the proposed high-resolution inverse geometry spectrometer on the SNS-Long Wavelength Target Station (LWTS). The LWTS will provide the high flux of long wavelength neutrons at the requisite pulse rate required by the spectrometer design. The resolution of this spectrometer lies between that routinely achieved by spin echo techniques and the design goal of the high power target station backscattering spectrometer. Covering this niche in energy resolution will allow systematic studies over the large dynamic range required by many disciplines, such as protein dynamics. (author)

  1. Eleventh DOE workshop on personnel neutron dosimetry

    International Nuclear Information System (INIS)

    1991-01-01

    Since its formation, the Office of Health (EH-40) has stressed the importance of the exchange of information related to and improvements in neutron dosimetry. This Workshop was the eleventh in the series sponsored by the Department of Energy (DOE). It provided a forum for operational personnel at DOE facilities to discuss current issues related to neutron dosimetry and for leading investigators in the field to discuss promising approaches for future research. A total of 26 papers were presented including the keynote address by Dr. Warren K. Sinclair, who spoke on, ''The 1990 Recommendations of the ICRP and their Biological Background.'' The first several papers discussed difficulties in measuring neutrons of different energies and ways of compensating or deriving correction factors at individual facilities. Presentations were also given by the US Navy and Air Force. Current research in neutron dosimeter development was the subject of the largest number of papers. These included a number on the development of neutron spectrometers

  2. The time-of-flight isochronous (TOFI) spectrometer for direct mass measurements of exotic light nuclei

    International Nuclear Information System (INIS)

    Wouters, J.M.; Vieira, D.J.; Butler, G.W.; Wollnik, H.; Kraus, R.H. Jr.; Vaziri, K.

    1987-01-01

    A new type of time-of-flight recoil spectrometer designed to measure the masses of neutron-rich light nuclei has recently been completed at LAMPF. The spectrometer relies on an isochronous design that directly correlates an ion's time-of-flight through the spectrometer with its mass-to-charge ratio. Additional measurements of the ion's velocity and energy enable the charge state of the recoil to be uniquely defined and thus permit precision mass measurements given sufficient statistics. The performance of the spectrometer has been investigated in both-off line (using alpha sources) and on-line tests. The design resolution of ΔM/M=1/2000 (fwhm) has been achieved. Initial performance results of the spectrometer are described with emphasis placed on the techniques used to achieve the overall high mass resolution and large solid angle/momentum acceptance. (orig.)

  3. Development of advanced neutron beam technology

    Energy Technology Data Exchange (ETDEWEB)

    Seong, B. S.; Lee, J. S.; Sim, C. M. (and others)

    2007-06-15

    The purpose of this work is to timely support the national science and technology policy through development of the advanced application techniques for neutron spectrometers, built in the previous project, in order to improve the neutron spectrometer techniques up to the world-class level in both quantity and quality and to reinforce industrial competitiveness. The importance of the research and development (R and D) is as follows: 1. Technological aspects - Development of a high value-added technology through performing the advanced R and D in the broad research areas from basic to applied science and from hard to soft condensed matter using neutron scattering technique. - Achievement of an important role in development of the new technology for the following industries aerospace, defense industry, atomic energy, hydrogen fuel cell etc. by the non-destructive inspection and analysis using neutron radiography. - Development of a system supporting the academic-industry users for the HANARO facility 2. Economical and Industrial Aspects - Essential technology in the industrial application of neutron spectrometer, in the basic and applied research of the diverse materials sciences, and in NT, BT, and IT areas - Broad impact on the economics and the domestic and international collaborative research by using the neutron instruments in the mega-scale research facility, HANARO, that is a unique source of neutron in Korea. 3. Social Aspects - Creating the scientific knowledge and contributing to the advanced industrial society through the neutron beam application - Improving quality of life and building a national consensus on the application of nuclear power by developing the RT fusion technology using the HANARO facility. - Widening the national research area and strengthening the national R and D capability by performing advanced R and D using the HANARO facility.

  4. Development of advanced neutron beam technology

    International Nuclear Information System (INIS)

    Seong, B. S.; Lee, J. S.; Sim, C. M.

    2007-06-01

    The purpose of this work is to timely support the national science and technology policy through development of the advanced application techniques for neutron spectrometers, built in the previous project, in order to improve the neutron spectrometer techniques up to the world-class level in both quantity and quality and to reinforce industrial competitiveness. The importance of the research and development (R and D) is as follows: 1. Technological aspects - Development of a high value-added technology through performing the advanced R and D in the broad research areas from basic to applied science and from hard to soft condensed matter using neutron scattering technique. - Achievement of an important role in development of the new technology for the following industries aerospace, defense industry, atomic energy, hydrogen fuel cell etc. by the non-destructive inspection and analysis using neutron radiography. - Development of a system supporting the academic-industry users for the HANARO facility 2. Economical and Industrial Aspects - Essential technology in the industrial application of neutron spectrometer, in the basic and applied research of the diverse materials sciences, and in NT, BT, and IT areas - Broad impact on the economics and the domestic and international collaborative research by using the neutron instruments in the mega-scale research facility, HANARO, that is a unique source of neutron in Korea. 3. Social Aspects - Creating the scientific knowledge and contributing to the advanced industrial society through the neutron beam application - Improving quality of life and building a national consensus on the application of nuclear power by developing the RT fusion technology using the HANARO facility. - Widening the national research area and strengthening the national R and D capability by performing advanced R and D using the HANARO facility

  5. Magnetic quadrupole and solenoidal spectrometers

    International Nuclear Information System (INIS)

    Laurent, H.; Schapira, J.P.

    1979-01-01

    General optical properties of magnetic quadrupole spectrometers are reviewed, together with experimental purposes for nuclear physics: background reduction, magnetic rigidity filtering for extreme forward angles measurements, light charged particle discrimination, ionic charge state separation, time of flight mass spectrometry and fast collection of radioactive nuclear reaction products. Possibility of alternative devices such as superconducting quadrupoles or solenoid spectrometers are discussed. (Auth.)

  6. The ALICE forward muon spectrometer

    Indian Academy of Sciences (India)

    ICE detector will allow to identify the quarkonium states through both the dielectron and the dimuon channels. For this purpose the apparatus is equipped with a transition radiation detector in its central part and with a forward muon spectrometer at small angles. After a brief description of the forward muon spectrometer, ...

  7. ATF beamline 1 analysis spectrometer

    International Nuclear Information System (INIS)

    Fernow, R.C.; Kirk, H.G.; Ulc, S.

    1993-01-01

    We describe the design parameters and expected performance of the analysis spectrometer for beamline 1 at the BNL Accelerator Test Facility. The spectrometer should be well suited for measuring the change in energy caused by the first generation laser acceleration experiments

  8. Neutron detector

    Science.gov (United States)

    Stephan, Andrew C [Knoxville, TN; Jardret,; Vincent, D [Powell, TN

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  9. Fusion neutronics

    CERN Document Server

    Wu, Yican

    2017-01-01

    This book provides a systematic and comprehensive introduction to fusion neutronics, covering all key topics from the fundamental theories and methodologies, as well as a wide range of fusion system designs and experiments. It is the first-ever book focusing on the subject of fusion neutronics research. Compared with other nuclear devices such as fission reactors and accelerators, fusion systems are normally characterized by their complex geometry and nuclear physics, which entail new challenges for neutronics such as complicated modeling, deep penetration, low simulation efficiency, multi-physics coupling, etc. The book focuses on the neutronics characteristics of fusion systems and introduces a series of theories and methodologies that were developed to address the challenges of fusion neutronics, and which have since been widely applied all over the world. Further, it introduces readers to neutronics design’s unique principles and procedures, experimental methodologies and technologies for fusion systems...

  10. The neutron

    International Nuclear Information System (INIS)

    Cheetham, A.K.

    1990-01-01

    In 1932, when Chadwick obtained the first unambiguous evidence for the existence of the neutron, his discovery confirmed the widely held belief that there existed a particle with zero charge and a mass similar to that of the proton. Indeed, as early as 1920, Lord Rutherford had suggested such a possibility in a lecture to the Royal Society. The discovery of the neutron had an immediate and dramatic impact in several areas. The nucleus, which had hitherto been regarded, somewhat unsatisfactorily, as a combination of protons and electrons, was now seen as comprising of protons and neutrons. This in turn lead to a proper understanding of the nature of isotopes and provided a fresh basis for nuclear theories. This paper examines the nature and properties of the neutron, and describes some facets of its remarkable role in contemporary science and technology. The aspects covered are its properties, the production and detection of neutrons, the reactions between neutrons and nuclei, fission reactions, neutron scattering, pulsed neutron scattering and neutron spectroscopy. (author)

  11. Atmospheric neutrons

    International Nuclear Information System (INIS)

    Preszler, A.M.; Moon, S.; White, R.S.

    1976-01-01

    Additional calibrations of the University of California double-scatter neutron and additional analysis corrections lead to the slightly changed neutron fluxes reported here. The theoretical angular distributions of Merker (1975) are in general agreement with our experimental fluxes but do not give the peaks for vertical upward and downward moving neutrons. The theoretical neutron escape current J 2 /sub pi/ (Merker, 1972; Armstrong et al., 1973) is in agreement with the experimental values from 10 to 100 MeV. Our experimental fluxes agree with those of the Kanbach et al. (1974) in the overlap region from 70 to 100 MeV

  12. Status of neutron diagnostics on the experimental advanced superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, G. Q.; Hu, L. Q., E-mail: lqhu@ipp.ac.cn; Pu, N.; Zhou, R. J.; Xiao, M.; Cao, H. R.; Li, K.; Huang, J.; Xu, G. S.; Wan, B. N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Zhu, Y. B. [Department of Physics and Astronomy, University of California, Irvine, California 92697-4575 (United States); Fan, T. S.; Peng, X. Y.; Du, T. F.; Ge, L. J. [School of Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, Chengfu Road 201, 100871 Beijing (China)

    2016-11-15

    Neutron diagnostics have become a significant means to study energetic particles in high power auxiliary heating plasmas on the Experimental Advanced Superconducting Tokamak (EAST). Several kinds of neutron diagnostic systems have been implemented for time-resolved measurements of D-D neutron flux, fluctuation, emission profile, and spectrum. All detectors have been calibrated in laboratory, and in situ calibration using {sup 252}Cf neutron source in EAST is in preparation. A new technology of digitized pulse signal processing is adopted in a wide dynamic range neutron flux monitor, compact recoil proton spectrometer, and time of flight spectrometer. Improvements will be made continuously to the system to achieve better adaptation to the EAST’s harsh γ-ray and electro-magnetic radiation environment.

  13. Polarized neutrons for Australian scientific research

    International Nuclear Information System (INIS)

    Kennedy, Shane J.

    2005-01-01

    Polarized neutron scattering has been a feature at ANSTO's HIFAR research reactor since the first polarization analysis (PA) spectrometer Longpol began operation over 30 years ago. Since that time, we have improved performance of Longpol and added new capabilities in several reincarnations of the instrument. Most of the polarized neutron experiments have been in the fields of magnetism and superconductivity, and most of that research has involved PA. Now as we plan our next generation neutron beam facility, at the Replacement Research Reactor (RRR), we intend to continue the tradition of PA but with a far broader scope in mind. Our new capabilities will combine PA and energy analysis with both cold and thermal neutron source spectra. We will also provide capabilities for research with polarized neutrons in small-angle neutron scattering and in neutron reflectometry. The discussion includes a brief historical account of the technical developments with a summary of past and present applications of polarized neutrons at HIFAR, and an outline of the polarized neutron capabilities that will be included in the first suite of instruments, which will begin operation at the new reactor in 2006

  14. Calibration of activation detectors in a monoenergetic neutron beam. Contribution to criticality dosimetry

    International Nuclear Information System (INIS)

    Massoutie, Martine.

    1981-05-01

    Activation detectors have been calibrated for critical dosimetry applications. Measurements are made using a monoenergetic neutron flux. 14 MeV neutrons obtained par (D-T) reaction are produced by 150 kV accelerator. Neutron flux determined by different methods leads us to obtain an accuracy better than 6%. The present dosimetric system (Activation Neutron Spectrometer - SNAC) gives few informations in the (10 keV - 2 MeV) energetic range. The system has been improved and modified so that SNAC detectors must be read out by gamma spectrometer [fr

  15. Electron-volt spectroscopy at a pulsed neutron source using a resonance detector technique

    CERN Document Server

    Andreani, C; Senesi, R; Gorini, G; Tardocchi, M; Bracco, A; Rhodes, N; Schooneveld, E M

    2002-01-01

    The effectiveness of the neutron resonance detector spectrometer for deep inelastic neutron scattering measurements has been assessed by measuring the Pb scattering on the eVS spectrometer at ISIS pulsed neutron source and natural U foils as (n,gamma) resonance converters. A conventional NaI scintillator with massive shielding has been used as gamma detector. A neutron energy window up to 90 eV, including four distinct resonance peaks, has been assessed. A net decrease of the intrinsic width of the 6.6 eV resonance peak has also been demonstrated employing the double difference spectrum technique, with two uranium foils of different thickness.

  16. Respiratory mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  17. Neutronic reactor

    International Nuclear Information System (INIS)

    Wende, C.W.J.

    1976-01-01

    A safety rod for a nuclear reactor has an inner end portion having a gamma absorption coefficient and neutron capture cross section approximately equal to those of the adjacent shield, a central portion containing materials of high neutron capture cross section and an outer end portion having a gamma absorption coefficient at least equal to that of the adjacent shield

  18. Neutron diffraction

    International Nuclear Information System (INIS)

    Bacon, G.E.

    1983-01-01

    The paper reviews neutron diffraction work from the early studies to the present-day development of the subject. Direct structural investigations were described, including chemical applications associated with single crystal techniques, and magnetic applications identified with powder techniques. The properties of the neutron beams are discussed, as well as the use of polarised beams. (UK)

  19. Neutron holography

    International Nuclear Information System (INIS)

    Beynon, T.D.

    1986-01-01

    the paper concerns neutron holography, which allows an image to be constructed of the surfaces, as well as the interiors, of objects. The technique of neutron holography and its applications are described. Present and future use of the method is briefly outlined. (U.K.)

  20. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...