WorldWideScience

Sample records for networks radon evaluation

  1. Monitoring network for radon in soil and water

    International Nuclear Information System (INIS)

    Tamez, E.; Pena, P.; Segovia, N.; Salazar, S.

    1996-01-01

    With the purpose to analyze the radon fluctuations on soil and ground waters that may be presented in seismic zones, it was installed a radon detection network that is localized as in the Pacific coasts, as in the Gulf of Mexico some of them localized near Laguna Verde power plant. The radon is detected systematically with solid state track detectors, LR115 Type II, which register the alpha particles of their radioactive decay. The evaluation of the alpha particles tracks was made with a counting system of spark type. Additionally, recently some automatic detection systems (silicide photodiodes) have been installed which register continuously the alpha particles, obtaining radon flux variations starting from registers got during short periods which are programmable between some hours and some tenths of days. Here are presented some results obtained with these systems. (Author)

  2. Radon levels in a water distribution network

    International Nuclear Information System (INIS)

    Alabdula'aly, A.I.

    1997-01-01

    The capital city of Saudi Arabia, Riyadh, relies on both desalinated sea water as well as treated groundwater to meet all its water requirements. About 66% of the water demand is met by desalinated sea water, and the remaining is supplied by six groundwater treatment plants located in the vicinity of the city and supplied with water from 161 wells. The desalinated sea water is blended with only one plant product water and pumped to the distribution network, whereas the other five plants product water is pumped directly to the network. A study of 222 Rn levels in the city distribution network was carried out in which 89 samples were collected from different locations representing the city districts. All samples have shown low radon levels with an average concentration of 0.2 Bq l -1 and a range values of 0.1-1.0 Bq l -1 . The level of radon in different parts of the network was found to be influenced by the water sources to which they are supplied. The lowest radon levels were observed in districts supplied mostly by desalinated sea water. (Author)

  3. Probabilistic neural network algorithm for using radon emanations as an earthquake precursor

    International Nuclear Information System (INIS)

    Gupta, Dhawal; Shahani, D.T.

    2014-01-01

    The investigation throughout the world in past two decades provides evidence which indicate that significance variation of radon and other soil gases occur in association with major geophysical events such as earthquake. The traditional statistical algorithm includes regression to remove the effect of the meteorological parameters from the raw radon and anomalies are calculated either taking the periodicity in seasonal variations or periodicity computed using Fast Fourier Transform. In case of neural networks the regression step is avoided. A neural network model can be found which can learn the behavior of radon with respect to meteorological parameter in order that changing emission patterns may be adapted to by the model on its own. The output of this neural model is the estimated radon values. This estimated radon value is used to decide whether anomalous behavior of radon has occurred and a valid precursor may be identified. The neural network model developed using Radial Basis function network gave a prediction rate of 87.7%. The same was accompanied by huge false alarms. The present paper deals with improved neural network algorithm using Probabilistic Neural Networks that requires neither an explicit step of regression nor use of any specific period. This neural network model reduces the false alarms to zero and gave same prediction rate as RBF networks. (author)

  4. The application of artificial neural network in radon disaster model of uranium mining

    International Nuclear Information System (INIS)

    Zhu Yufeng; Zhu Guogen; Zhou Shijian

    2012-01-01

    The structural features, data analysis and learning process of feed-forward neural network (BP ANN) were analyzed at first. Rodon sample from Fuzhou Jinan Uranium Industry Limited Company were used to training the network and make the forecast then, and a forecasting model was established for the radon disaster in uranium mines. The method and effectiveness of BP neural network in predicting radon disaster was discussed. The test of training samples showed that the BP network had gotten fairly satisfied result in predicting mine radon disaster. (authors)

  5. Evolution of radon dose evaluation

    Directory of Open Access Journals (Sweden)

    Fujimoto Kenzo

    2004-01-01

    Full Text Available The historical change of radon dose evaluation is reviewed based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR reports. Since 1955, radon has been recognized as one of the important sources of exposure of the general public. However, it was not really understood that radon is the largest dose contributor until 1977 when a new concept of effective dose equivalent was introduced by International Commission on Radiological Protection. In 1982, the dose concept was also adapted by UNSCEAR and evaluated per caput dose from natural radiation. Many researches have been carried out since then. However, lots of questions have remained open in radon problems, such as the radiation weighting factor of 20 for alpha rays and the large discrepancy of risk estimation among dosimetric and epidemiological approaches.

  6. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  7. Identification of radon anomalies in soil gas using decision trees and neural networks

    International Nuclear Information System (INIS)

    Zmazek, B.; Dzeroski, S.; Torkar, D.; Vaupotic, J.; Kobal, I.

    2010-01-01

    The time series of radon ( 222 Rn) concentration in soil gas at a fault, together with the environmental parameters, have been analysed applying two machine learning techniques: (I) decision trees and (II) neural networks, with the aim at identifying radon anomalies caused by seismic events and not simply ascribed to the effect of the environmental parameters. By applying neural networks, 10 radon anomalies were observed for 12 earthquakes, while with decision trees, the anomaly was found for every earthquake, but, undesirably, some anomalies appeared also during periods without earthquakes. (authors)

  8. Evaluation method of radon preventing effect in underground construction

    International Nuclear Information System (INIS)

    Luo Shaodong; Deng Yuequan; Dong Faqin; Qu Ruixue; Xie Zhonglei

    2014-01-01

    Background: It's difficult to evaluate the radon prevention effect because of the short operating time of measuring instrument under the circumstances of high humidity in underground construction. Purpose: A new rapid method to evaluate the radon prevention efficiency of underground construction was introduced. Methods: The radon concentrations before and after shielding operation were determined, and according to the regularity of radon decay, the shielding rate can be calculated. Results: The results showed that radon shielding rate in underground construction remains generally stable with variation of time, and the actual relatively standard deviation was 3.95%. So the rapid determination and evaluation of radon preventing effect under special conditions in underground construction can be realized by taking shielding rate in a short time for the final shielding rate. Compared with those by the local static method in ground lab, the results were similar. Conclusion: This paper provided a prompt, accurate and practicable way for the evaluation of radon prevention in underground construction, having a certain reference value. (authors)

  9. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  10. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  11. Indigenous development and networking of online radon monitors in the underground uranium mine

    International Nuclear Information System (INIS)

    Gaware, J.J.; Sahoo, B.K.; Sapra, B.K.; Mayya, Y.S.

    2011-01-01

    There has been a long standing demand for online monitoring of radon level in various locations of underground Uranium mine for taking care of radiological protection to workers. Nowadays, radon ( 222 Rn) monitors, based on electrostatic collection of charged progeny and subsequent detection by semiconductor detector are increasingly employed for radon monitoring in environment. However, such instruments have some limitations such as (i) requirement of additional dryer since sensitivity is dependent on the humidity (ii) cannot be connected to a network and (iii) not cost effective etc. Hence use of such instruments in underground uranium mine (humidity level >90), may not be reliable. Towards this end, we have indigenously developed radon monitor based on electrostatic collection and scintillation technology for the online monitoring in uranium mine. This instrument overcomes the above mentioned limitation of commercial radon monitors and based on custom made features. Different tests and measurements were carried out and compared with commercial instruments. It was found to be in an excellent agreement with the commercial instruments. A few such instruments have been installed in different locations of uranium mine at Turamdih and connected to a network system for online monitoring and display. (author)

  12. Communicating radon risk effectively: a mid-course evaluation. Interim report

    International Nuclear Information System (INIS)

    Smith, V.K.; Desvousges, W.H.; Fisher, A.; Johnson, F.R.

    1987-07-01

    A panel of 2300 homeowners was divided into subgroups to test the effectiveness of six alternative ways of explaining the risk from naturally occurring radon gas. The research design focused on two dimensions: qualitative vs. quantitative and directive vs. evaluative. These characteristics led to 4 experimental booklets, which were compared with EPA's Citizen's Guide and a one-page fact sheet. The evaluation examined how much people learned about radon; whether they could form risk perceptions consistent with their home's measured radon level; and whether they felt they had enough information to make a decision about mitigation. The fact sheet did not perform well on any of these evaluation criteria. None of the five booklets clearly was best for all 3 evaluation criteria; the report discusses the implications for designing an effective radon-risk communication program

  13. Evaluation of Radon Pollution in Underground Parking Lots by Discomfort Index

    Directory of Open Access Journals (Sweden)

    AH Bu-Olayan

    2016-06-01

    Full Text Available Introduction Recent studies of public underground parking lots showed the influence of radon concentration and the probable discomfort caused by parking cars. Materials and Methods Radon concentration was measured in semi-closed public parking lots in the six governorates of Kuwait, using Durridge RAD7radon detector (USA. Results The peak radon concentration in the parking lots of Kuwait governorates was relatively higher during winter (63.15Bq/m3 compared to summer (41.73 Bq/m3. Radon in the evaluated parking lots revealed a mean annual absorbed dose (DRn: 0.02mSv/y and annual effective dose (HE: 0.06mSv/y.  Conclusion This study validated the influence of relative humidity and temperature as the major components of discomfort index (DI. The mean annual absorbed and effective dose  of radon in the evaluated parking lots were found below the permissible limits. However, high radon DRn and HE were reported when the assessment included the parking lots, the surrounding residential apartments, and office premises. Furthermore, the time-series analysis indicated significant variations of the seasonal and site-wise distribution of radon concentrations in the indoor evaluated parking lots of the six Kuwait governorates

  14. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  15. The radon: evaluation and risk management; Le radon: evaluation et gestion du risque

    Energy Technology Data Exchange (ETDEWEB)

    Lacoste, A.C. [Direction Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Masse, R. [Academie des Technologies, 75 - Paris (France); Aurengo, A. [Hopital Pitie-Salpetriere, Service de Medecine Nucleaire, 75 - Paris (France); Erich Wichmann, H. [Neuberberg Munich Univ. (Germany); Timarche, M.; Laurier, D.; Robe, M.Ch. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92 - Clamart (France); Baubron, J.C.; Bonijoly, D. [BRGM, 75 - Paris (France); Collignan, B. [Centre Scientifique et Technique du Batiment, (CSTB), 75 - Paris (France); Berrier, H. [Direction Gle de l' Urbanisme de l' Habitat et de la Construction, 75 - Paris (France); Jaouen, J. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Vienne (France); Caamano, D. [Direction Departementale des Affaires Sanitaires et Sociales de l' Essonne, 91 (France); Guiot, F. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Marne (France); Grall, B. [Direction Departementale des Affaires Sanitaires et Sociales de Bretagne (France); Frutos Vasquez, B.; Olaya Adan, M. [Istituto de Ciencias de la Construction (Italy); Garcia Cadierno, J.P.; Martin Matarranz, J.L.; Serrano Renedo, J.; Suarez Mahou, E. [Consejo de Seguridad Nuclear, Madrid (Spain); Fernandez, J.A. [ENUSA Industrias Avanzadas (Spain); Mjones, L.; Pirard, P. [Institut de veille sanitaire, 94415 - Saint-Maurice (France); Godet, J.L.; Rougy, Ch. [Direction Gle de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France)

    2003-06-15

    The radon exposure constitutes for the French population the first cause of natural irradiation among the different natural sources of irradiation. It is possible to have a significant action on it, either by making draught proof in order to avoid to radon to get inside houses, either by ventilating in order to dispel the radon and improve air quality. (N.C.)

  16. The radon in Corsica: evaluation of exposure and associated risks; Le radon en Corse: evaluation de l'exposition et des risques associes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    The average level found in Corsica is superior to that one found in France. On the basis of the results of it campaign I.R.S.N.-D.G.S., the French average is of 90 Bq.m{sup 3} against 197 Bq.m{sup 3} for Corsica. The risk of dying from a lung cancer attributable to the radon was estimated at 13 % in France. The evaluation of risk led on Corsica shows a risk attributable to the radon included between 21.5 and 28 %.This evaluation of risk is only a stage. It is important to arrest better the exposure to the radon of the Corsican population. For a good estimation of the levels of radon and thus the impact of this one, additional measures are necessary. The results of the data analysis of exposure allow to guide the choice of the new measures: a campaign on the season effect in Corsica and a completion of the measures in housing are two main axes.Seen the importance of the interaction between the tobacco and the radon, a good estimation of the tobacco customs in Corsica and its evolution in the time seems essential to estimate indeed the impact of the radon in this region. (N.C.)

  17. Indigenous development and networking of online radon monitors in the underground uranium mine

    International Nuclear Information System (INIS)

    Gaware, J.J.; Sahoo, B.K.; Sapra, B.K.; Mayya, Y.S.

    2010-01-01

    Full text: There has been a long standing demand for online monitoring of radon level in various locations of underground uranium mine for taking care of radiological protection to workers. Nowadays, radon ( 222 Rn) monitors, based on semiconductor detector are increasingly employed for radon monitoring in environment. However, such instruments have some limitations such as (i) requirement of additional dryer in the sampling path, (ii) cannot be connected to a online data logging and monitoring network, (iii) not cost effective for large number of installations. Due to need for dryer, unattended continuous operation of such instruments is not possible particularly in underground uranium mine with humidity in the range of 80 to 98 %. So it is required to develop radon monitors which overcome the above limitations so that large number of monitors can be deployed in the uranium mine. Often radon progeny is electrostatically collected on the detector surface to increase the sensitivity. However, the collection efficiency is highly dependent upon the humidity and trace gas concentration in the sample gas due to charge neutralization effect. This effect can be minimized by applying a high electric field throughout the detector's chamber volume. This cannot be achieved using planner silicon PIN diode (area ∼ 4 cm 2 ) due to its inherent size limitations. This is because the electric field, in case of small inner electrode, falls off rapidly towards the outer electrode. Hence, an instrument has been indigenously developed by designing an annular cylindrical chamber with larger inner cathode (area = 140 cm 2 ) by employing flexible ZnS:Ag sheet (scintillation detector). With this design, the high sensitivity of 2.8 cph/Bqm -3 has been accomplished with the nominal deviation within 15% for vast change in humidity of 5% to 95%. In this instrument, although the alpha spectroscopy is not possible, the high sensitivity of the instruments makes it possible to achieve the MDL as

  18. Large-scale radon hazard evaluation in the Oslofjord region of Norway utilizing indoor radon concentrations, airborne gamma ray spectrometry and geological mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark Andrew; Strand, Terje; Sundal, Aud Venke; Rudjord, Anne Liv

    2008-01-01

    We test whether airborne gamma ray spectrometer measurements can be used to estimate levels of radon hazard in the Oslofjord region of Norway. We compile 43,000 line kilometres of gamma ray spectrometer data from 8 airborne surveys covering 10,000 km 2 and compare them with 6326 indoor radon measurements. We find a clear spatial correlation between areas with elevated concentrations of uranium daughters in the near surface of the ground and regions with high incidence of elevated radon concentrations in dwellings. This correlation permits cautious use of the airborne data in radon hazard evaluation where direct measurements of indoor radon concentrations are few or absent. In radon hazard evaluation there is a natural synergy between the mapping of radon in indoor air, bedrock and drift geology mapping and airborne gamma ray surveying. We produce radon hazard forecast maps for the Oslofjord region based on a spatial union of hazard indicators from all four of these data sources. Indication of elevated radon hazard in any one of the data sets leads to the classification of a region as having an elevated radon hazard potential. This approach is inclusive in nature and we find that the majority of actual radon hazards lie in the assumed elevated risk regions

  19. Evaluation of radon progeny from Mount St. Helens eruptions. Final report

    International Nuclear Information System (INIS)

    Lepel, E.A.; Olsen, K.B.; Thomas, V.W.; Eichner, F.N.

    1982-09-01

    A network of twelve monitoring sites around Mount St. Helens was established to evaluate possible short-lived radioactivity in the fallen ash. Seven sites were located near major population centers of Washington and Oregon, and five sites were located within 80 km of the volcano. Each site monitored the radioactivity present by the use of thermoluminescent dosimeters which recorded the total exposure to radioactivity over the exposure period. Eruptions occurring on July 22, August 7, and October 16 to 18, 1980 were monitored. No statistically significant quantities of measurable radon daughters were observed

  20. The radon in Corsica: evaluation of exposure and associated risks

    International Nuclear Information System (INIS)

    2006-02-01

    The average level found in Corsica is superior to that one found in France. On the basis of the results of it campaign I.R.S.N.-D.G.S., the French average is of 90 Bq.m 3 against 197 Bq.m 3 for Corsica. The risk of dying from a lung cancer attributable to the radon was estimated at 13 % in France. The evaluation of risk led on Corsica shows a risk attributable to the radon included between 21.5 and 28 %.This evaluation of risk is only a stage. It is important to arrest better the exposure to the radon of the Corsican population. For a good estimation of the levels of radon and thus the impact of this one, additional measures are necessary. The results of the data analysis of exposure allow to guide the choice of the new measures: a campaign on the season effect in Corsica and a completion of the measures in housing are two main axes.Seen the importance of the interaction between the tobacco and the radon, a good estimation of the tobacco customs in Corsica and its evolution in the time seems essential to estimate indeed the impact of the radon in this region. (N.C.)

  1. Evaluation and control of radon daughter hazards in uranium mines

    International Nuclear Information System (INIS)

    Holaday, D.A.

    1974-11-01

    This monograph discusses primarily those health hazards to uranium miners which are produced by exposure to ionizing radiation. Emphasis is placed on the areas of evaluation of exposures to the radioactive gas radon-222 and its short-lived transformation products, and methods of controlling such exposures. A limited discussion of the biological effects of radon and radon daughters is undertaken, and some procedures are given for evaluating hazards created by other common contaminants of mine atmospheres. A large amount of information exists on these topics, some of which is unpublished or is not readily available. While efforts were made to obtain data from all sources, undoubtedly some valuable work was overlooked. The monograph is an endeavor to assemble pertinent information and make it available to those who are concerned with producing uranium at minimal risks. Where they were available, a variety of procedures for evaluating hazards are given, and examples of systems for controlling hazards are included. 154 references

  2. Risk evaluation and control strategies for indoor radon: a brief discussion

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1994-01-01

    Average risks of death estimated for radon are larger than those for many exposures in the outdoor environment, but similar to some in industrial settings. However, the indoor environment differs in regard to cost, benefit, responsibility, and distribution of risks from the outdoor and occupational settings, where frameworks for setting risk-limiting objectives and strategies have already been developed substantially. This indicates the need to develop a conceptual framework for evaluating risks in the indoor environment, within which the objectives of radon control strategies can be sensibly chosen. Nevertheless, the range of estimated radon risks and of recent radon control strategies suggest near-term elements of any strategy, i.e. accurate and effective public information, as well as reliable monitoring and control capabilities, and a focus on areas where most high residential levels occur. Developing a conceptual framework for evaluating indoor risks will permit the formulation of suitable aims on average indoor exposures and lower exposure situations. (author)

  3. The radon: evaluation and risk management

    International Nuclear Information System (INIS)

    Lacoste, A.C.; Masse, R.; Aurengo, A.; Erich Wichmann, H.; Timarche, M.; Laurier, D.; Robe, M.Ch.; Baubron, J.C.; Bonijoly, D.; Collignan, B.; Berrier, H.; Jaouen, J.; Caamano, D.; Guiot, F.; Grall, B.; Frutos Vasquez, B.; Olaya Adan, M.; Garcia Cadierno, J.P.; Martin Matarranz, J.L.; Serrano Renedo, J.; Suarez Mahou, E.; Fernandez, J.A.; Mjones, L.; Pirard, P.; Godet, J.L.; Rougy, Ch.

    2003-01-01

    The radon exposure constitutes for the French population the first cause of natural irradiation among the different natural sources of irradiation. It is possible to have a significant action on it, either by making draught proof in order to avoid to radon to get inside houses, either by ventilating in order to dispel the radon and improve air quality. (N.C.)

  4. First year evaluation of EPA's radon contractor proficiency (RCP) program

    International Nuclear Information System (INIS)

    Salmon, G.L.

    1990-01-01

    This paper reports that the Environmental Protection Agency (EPA) has developed a voluntary program to evaluate radon reduction contractors and provide this information to the public, as part of activities mandated by the Indoor Radon Abatement Act (IRAA) of 1988. The Radon Contractor Proficiency Program consists of several elements that collectively help to ensure the proficiency of radon mitigators and give the public greater confidence in their capability. Contractors who participate in the program must pass a written examination, adhere to mitigation guidelines, keep records of work, meet continuing education requirements and pass a re-examination every two years. Upon meeting the program's requirements, mitigators are listed in EPA's National RCP Proficiency Report. The first Report released on May 15, 1990 listed 636 contractors. The second Report, to be release in August, will list 895 contractors, representing an increase of 40 per cent

  5. Determination of radon concentration in drinking water resources of villages nearby Lalehzar fault and evaluation the annual effective dose

    International Nuclear Information System (INIS)

    Mohammad Malakootian; Zahra Darabi Fard; Mojtaba Rahimi

    2015-01-01

    The radon concentration has been measured in 44 drinking water resources, in villages nearby Lalehzar fault in winter 2014. Some samples showed a higher concentration of radon surpassing limit set by EPA. Further, a sample was taken from water distribution networks for these sources of water. Soluble radon concentration was measured by RAD7 device. Range radon concentration was 26.88 and 0.74 BqL -1 respectively. The maximum and minimum annual effective dose for adults was estimated at 52.7 and 2.29 µSvY -1 , respectively. Reducing radon from water before use is recommended to improve public health. (author)

  6. Lessons from radon

    International Nuclear Information System (INIS)

    Nichols, M.

    1993-01-01

    At EPA there is a public outreach program that the Office of Air and Radiation (OAR) has developed for radon. To meet the difficult challenge radon presented, OAR's Radon Division developed working relationships with national nonprofit groups who share a mission. These groups have well-established communication networks with their memberships for advancing their goals. Such diverse groups as the American Lung Association, the Advertising Council, the National Association of Counties (NACo), the Consumer Federation of America, the National Association of Homebuilders, and the National Safety Council have joined with EPA to reduce radon health risks. Through this alliance, EPA has been able to take advantage of communication channels that it could never replicate on tis own. Every group working with EPA disseminates the radon message through its own established channels to reach its constituency. These partners wield authority in their fields and are ideal for addressing the concerns of their audiences

  7. Determination of Radon Level in Drinking Water in Mehriz Villages and Evaluation the Annual Effective Absorbed Dose

    OpenAIRE

    Mohammad Malakootian; Hasan Salmani Marvast

    2015-01-01

    Introduction: Radon is one of the most radioactive elements that may be found in soil, air and water naturally. Presence of fault and also granitic rocks near the water sources can cause high radon levels in these water resources. Radon concentration of various drinking water sources And network In Mehriz Villages was measured from Anar- Mehriz fault and granite stone of Shirkooh area. Material and Methods: This was a cross sectional research that was conducted in fall of 2013 on the sourc...

  8. Transport studies of radon in limestone underlying houses

    International Nuclear Information System (INIS)

    Gammage, R.B.; Dudney, C.S.; Wilson, D.L.; Saultz, R.J.

    1990-01-01

    In hilly limestone terrains of the southern Appalachians, subterranean networks of solution cavities and fissures present circulatory systems facilitating convective and advective transport of radon-bearing gas. Evidence suggests that the primary driving forces for transport are aerostatic pressure differentials created by the difference between the underground and the outside air temperatures. Examples are presented of houses experiencing elevated indoor radon levels as a consequence of communicating with such subsurface transportation systems. The location of a house near the upper or lower end of a subterranean-circulatory system seems to produce amplification of indoor radon levels in winter or summer, respectively. The transport mechanism for radon-bearing air in karst and its impact on indoor radon need better understanding, both in regard to evaluating the geographical prevalence of the phenomenon and the induced spatial and temporal effects that are possible. This paper reports field studies made at houses in karst regions at Oak Ridge, Tennessee, and Huntsville, Alabama. A primary radon-transport mechanism is advocated of ascending or descending subsurface columns of air whose flows are largely driven by aerostatic pressure gradients created by the inground-outdoor air temperature differentials. 5 refs., 5 figs., 1 tab

  9. Development of apparatus and procedures for evaluating radon-resistant construction materials

    International Nuclear Information System (INIS)

    Pugh, T.D.; Greenfield, M.B.; MacKenzie, J.; Meijer, R.J. de

    1992-01-01

    Laboratory facilities and apparatus have been constructed to measure radon exhalation from, and radon permeability through, various construction materials. This phase of the project has focused on development of test apparatus and evaluation of instrumentation. Results indicate significant spatial variability in the radon permeability of polyethylene, even when all test samples were selected from the same roll of material, and when no visible differentiation could be made regarding sample quality. Implications for code enforcement are described, and recommendations are offered for refinement of equipment and the measurement process, prioritization of future materials testing, and specific building code provisions, based on our results

  10. Preliminary evaluation of the control of indoor radon daughter levels in new structures

    International Nuclear Information System (INIS)

    Fitzgerald, J.E. Jr.; Guimond, R.J.

    1976-01-01

    As part of its assessment of the radiological impact of the phosphate industry in Florida, the US Environmental Protection Agency has surveyed residences built atop uraniferous reclaimed phosphate mining land. These surveys have shown elevated radon daughter levels to exist in structures built on this land. In order to allow safer use of this land for residential construction, various state-of-the-art radon daughter control technologies were evaluated by the Agency. These included forced ventilation, polymeric sealants, excavation, crawl space construction, and improved slab quality. From a cost-effectiveness evaluation, improved slab quality and crawl space construction were determined to best satisfy the criteria for optimal radon daughter control

  11. A numerical study on the performance evaluation of ventilation systems for indoor radon reduction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Eun; Park, Hoon Chae; Choi, Hang Seok; Cho, Seung Yeon; Jeong, Tae Young; Roh, Sung Cheoul [Yonsei University, Wonju (Korea, Republic of)

    2016-03-15

    Numerical simulations were conducted using computational fluid dynamics to evaluate the effect of ventilation conditions on radon ({sup 222}Rn) reduction performance in a residential building. The results indicate that at the same ventilation rate, a mechanical ventilation system is more effective in reducing indoor radon than a natural ventilation system. For the same ventilation type, the indoor radon concentration decreases as the ventilation rate increases. When the air change per hour (ACH) was 1, the indoor radon concentration was maintained at less than 100 Bq/m{sup 3}. However, when the ACH was lowered to 0.01, the average indoor radon concentration in several rooms exceeded 148 Bq/ m{sup 3}. The angle of the inflow air was found to affect the indoor air stream and consequently the distribution of the radon concentration. Even when the ACH was 1, the radon concentrations of some areas were higher than 100 Bq/m{sup 3} for inflow air angles of 5 .deg. and 175 .deg.

  12. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offermann, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. Of the devices we examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. Furthermore, at the low particle concentrations, plateout of the unattached radon progeny was found to be a significant removal mechanism. The overall removal rates due to deposition of attached and unattached progeny have been estimated from these data, and the equilibrium factors for total and unattached progeny concentrations have been calculated as a function of particle concentration. 7 references, 2 figures

  13. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offerman, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.; Yater, J.

    1984-01-01

    Eleven portable air cleaing devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. Of the devices we examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. Futhermore, at the low particle concentrations, plateout of the unattached radon progeny was found to be a significant removal mechanism. The overall removal rates due to deposition of attached and unattached progeny have been estimated from these data, and the equilibrium factors for total and unattached progeny concentrations have been calculated as a function of particle concentration. (Author)

  14. Radon and its hazards

    International Nuclear Information System (INIS)

    Chang Guilan

    2002-01-01

    The author describes basic physical and chemical properties of radon and the emanation, introduces methods of radon measurement, expounds the hazards of non-mine radon accumulation to the health of human being and the protection, as well as the history how the human being recognizes the hazards of radon through the specific data and examples, and finally proposes protecting measures to avoid the hazards of radon to the health of human being, and to do ecologic evaluation of environments

  15. An evaluation of passive methods for measurement of radon in dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Lind, B.; Kolstad, A.K.

    1989-01-01

    During the last ten years, different methods have been developed for the measurement of radon in indoor air. In this report the different methods in use by private firms in Norway have been compared. The results of the study show that the methods are quite different in regard to integration time, detection limit and reliability in measurements of radon in indoor air. In 1988 the National Institute of Radiation Hygiene gave directives on the performance of such measurements. In these directives, minimum limits have been set for integration time (7 days) for methods to be used in evaluations of remedial actions. In this report the results from a simple, anonymeous reliability test are reported. The test covered the private firms offering radon meassurement services in Norway. The frequently reported weaknesses by the charcoal method were confirmed in the study. The directives on radon measurements in dwellings are presented. 73 refs.; 11 figs.; 5 tabs

  16. A European Commission software tool for radon risk calculation and evaluation of countermeasures

    Energy Technology Data Exchange (ETDEWEB)

    Degrange, J.P.; Levy, F.P. [CEPN, Fontenay-aux-Roses Cedex (France); Birchall, A.; Haylock, R.; Marsh, J.; Muirhead, C. [National Radiological Protection Board, Chilton (United Kingdom); Janssens, A. [European Commission, DG XI (Luxembourg)

    2000-05-01

    The effects of exposure to radon on workers and members of the public have been examined for many years. Recent advances have been made in evaluating the risk associated with radon exposure and in implementing remediation programmes in dwellings. However, decisions about whether to implement countermeasures to reduce radon exposures may benefit from an enhanced capability to evaluate and understand the associated health risk. In this context, the European Commission has launched a project to develop a user friendly software package based upon current information on radon epidemiology, radon dosimetry, demography, and countermeasure efficiency. The software has been designed to perform lung cancer risk calculations specific to European populations for various exposure profiles and to evaluate, in terms of risk reduction, the efficiency of various countermeasures in dwellings. This paper presents an overview of the general structure of the software and outlines its most important modelling approaches. The software is able to evaluate the risk of fatal lung cancer associated with individual or collective exposure to radon. The individual risk calculation module determines, for an individual of given age, sex and tobacco consumption, the excess risk for a given exposure (past or future exposure) time-profile, on the basis of demographic data (WHO, 1996 and 1998) specific to the selected population. The collective risk calculation module determines the excess risk for each occupant of a dwelling, for an exposure time-profile derived from data describing the dwelling, its occupancy, and the chosen countermeasures. These calculations may be done using one of two classical approaches: 1) The epidemiological approach in which the risk is obtained directly from the radon exposure data using a risk model (BEIR IV, 1988; BEIR VI, 1999) derived from epidemiological studies of uranium miners; 2) The dosimetric approach in which the risk is derived from the radon exposure data

  17. A European Commission software tool for radon risk calculation and evaluation of countermeasures

    International Nuclear Information System (INIS)

    Degrange, J.P.; Levy, F.P.; Birchall, A.; Haylock, R.; Marsh, J.; Muirhead, C.; Janssens, A.

    2000-01-01

    The effects of exposure to radon on workers and members of the public have been examined for many years. Recent advances have been made in evaluating the risk associated with radon exposure and in implementing remediation programmes in dwellings. However, decisions about whether to implement countermeasures to reduce radon exposures may benefit from an enhanced capability to evaluate and understand the associated health risk. In this context, the European Commission has launched a project to develop a user friendly software package based upon current information on radon epidemiology, radon dosimetry, demography, and countermeasure efficiency. The software has been designed to perform lung cancer risk calculations specific to European populations for various exposure profiles and to evaluate, in terms of risk reduction, the efficiency of various countermeasures in dwellings. This paper presents an overview of the general structure of the software and outlines its most important modelling approaches. The software is able to evaluate the risk of fatal lung cancer associated with individual or collective exposure to radon. The individual risk calculation module determines, for an individual of given age, sex and tobacco consumption, the excess risk for a given exposure (past or future exposure) time-profile, on the basis of demographic data (WHO, 1996 and 1998) specific to the selected population. The collective risk calculation module determines the excess risk for each occupant of a dwelling, for an exposure time-profile derived from data describing the dwelling, its occupancy, and the chosen countermeasures. These calculations may be done using one of two classical approaches: 1) The epidemiological approach in which the risk is obtained directly from the radon exposure data using a risk model (BEIR IV, 1988; BEIR VI, 1999) derived from epidemiological studies of uranium miners; 2) The dosimetric approach in which the risk is derived from the radon exposure data

  18. A statistical evaluation of the geogenic controls on indoor radon concentrations and radon risk

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D., E-mail: jda@bgs.ac.u [British Geological Survey, Kingsley Dunham Centre, Nicker Hill, Keyworth, Nottingham, NG12 5GG (United Kingdom); Miles, J.C.H. [Health Protection Agency (HPA), Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2010-10-15

    ANOVA is used to show that approximately 25% of the total variation of indoor radon concentrations in England and Wales can be explained by the mapped bedrock and superficial geology. The proportion of the total variation explained by geology is higher (up to 37%) in areas where there is strong contrast between the radon potential of sedimentary geological units and lower (14%) where the influence of confounding geological controls, such as uranium mineralisation, cut across mapped geological boundaries. When indoor radon measurements are grouped by geology and 1-km squares of the national grid, the cumulative percentage of the variation between and within mapped geological units is shown to be 34-40%. The proportion of the variation that can be attributed to mapped geological units increases with the level of detail of the digital geological data. This study confirms the importance of radon maps that show the variation of indoor radon concentrations both between and within mapped geological boundaries.

  19. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations. Revision

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offermann, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-11-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. The experiments were conducted in a room-size chamber using cigarette smoke and radon injection from an external source. Of the devices examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be essentially negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. At the low particle concentrations, deposition of the unattached radon progeny on room surfaces was found to be a significant removal mechanism. Deposition rates of attached and unattached progeny have been estimated from these data, and were used to calculate the equilibrium factors for total and unattached progeny concentrations as a function of particle concentration. While particle removal reduces total airborne radon progeny concentrations, the relative alpha decay dose to the lungs appears to change very little as the particle concentration decreases due to the greater radiological importance of unattached progeny

  20. Radon in uranium mining industry and application of SSNTD in monitoring and dose evaluation

    International Nuclear Information System (INIS)

    Khan, A.H.

    2006-01-01

    Radon is present everywhere and accounts for a globally major share of natural radiation exposure of the population. Though it is present in most of the underground workings it is a source of concern in uranium mining and ore processing industry as well as in many other operations carried out in confined spaces below the ground, like railway tunnels and non-uranium underground mines. Many monitoring techniques are available for evaluation of radon and its short-lived progeny concentrations. Scintillation cell techniques, also called Lucas cell, is one of the earliest developed methods of radon monitoring still widely used in mines where appreciable concentrations of radon above about 40-50 Bq.m -3 are expected. For low concentration of radon as observed in the atmosphere, dwellings and other workplaces, the radon absorption in charcoal followed by gamma counting, two filter method and electrostatic techniques are available. Solid state nuclear track detectors (SSNTD) are now widely used for a variety of situations for monitoring of low level of radon over an extended period of time. It is now extensively used in radon monitoring in dwellings and also in radon dosimetry in mines. Radon daughters being the more important contributors to the internal radiation exposure are also being monitored using conventional techniques as well as SSNTD. Various monitoring techniques for radon and its progeny and the concentrations observed at different stages of uranium mining, ore processing and tailings management are discussed in this presentation. (author)

  1. Evaluation of strategies for promoting effective radon mitigation. Risk communication and economic research series. Final report

    International Nuclear Information System (INIS)

    Doyle, J.K.; McClelland, G.H.; Schulze, W.D.; Locke, P.A.; Elliott, S.R.

    1990-03-01

    The Environmental Protection Agency has estimated that as many as 20,000 lung cancer deaths per year in the United States can be attributed to exposure to radon gas. The report evaluates alternative strategies for motivating people to test for radon gas in their homes and to mitigate if necessary. Specifically, two separate radon information and awareness programs were evaluated, one targeted to the general population in the Washington, D.C. area and the other to home buyers in the Boulder, Colorado area. The results suggest that a home buyer program is likely to be far more effective in terms of effective remediation to reduce home radon levels than a program aimed at the general population. The report discusses the empirical findings and develops a recommendation for increasing the effectiveness of radon awareness and mitigation programs

  2. Radon Moscow: internationalisation of experience

    International Nuclear Information System (INIS)

    Nevejkin, P.P.; Grishin, O.E.; Rakov, S.M.

    2011-01-01

    Since the early 1990s, SIA Radon Moscow has been an active participant in the international technical cooperation to resolve the current issues of radiation safety and radwaste management. The article presents the experience of such cooperation. Examples of Radon's participation in the international projects on the assessment of safety, the international education network DISPONET and implementation of TACIS projects are given [ru

  3. Human perception of radon risk and radon mitigation: Some remarks

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.

    2008-01-01

    The Radon program in the Czech Republic has a relatively long and rich history. Procedures, which enable to evaluate the risk of radon penetration from the ground, to protect new buildings, to find existing buildings with elevated indoor radon levels and to realise remedial measures in such buildings, have been developed, published and tested. In some cases, the whole system may fail due to psychological or sociological reasons. Three types of problems (conflicts) will be presented: human behaviour affecting measurement results, conflict between individual and 'all-society' points of view, interpretation of radon risk itself. (authors)

  4. Development and evaluation of radon sealants for uranium mines

    International Nuclear Information System (INIS)

    Hammon, H.G.; Ernst, K.; Gaskill, J.R.; Newton, J.C.; Morris, C.J.

    1975-01-01

    Coatings for use as radon barriers were evaluated. Coating materials evaluated included epoxy resins, furfuryl alcohol polymers, styrenated polyesters, polyvinyl acetate, and acrylic emulsions. It was calculated that virtually all coatings with permeation constants lower than 10 -10 cm 3 /sub STP/ . cm/s . cm 2 .cm Hg and thicknesses between 5 and 10 mil will provide nearly 100 percent effectiveness. The selection of a suitable coating then ought to be based on other factors such as cost/m 2 , vapor toxicity during application, ability to bind to the uranium ore in continuous films free of pin-holes etc. Obviously, any openings in the mine shafts and tunnels which are not covered with a film or any discontinuities of the film will act like the spillway on a water dam, i.e., the radon contained behind the barrier will flow out into the tunnel. (U.S.)

  5. In-situ performance evaluation of radon measurement techniques in Uranium mine exhausts of Jaduguda

    International Nuclear Information System (INIS)

    Patnaik, R.L.; Jha, V.N.; Singh, M.K.; Meena, J.S.; Rajesh Kumar; Srivastava, V.S.; Sethy, N.K.; Ravi, P.M.; Tripathi, R.M.

    2014-01-01

    Several techniques are used for the measurement of the activity concentration of radon in the work place and the environment. Devices like Scintillation cell, Alpha guard and Low Level Radon Detection System (LLRDS) are widely used for the estimation of radon. Some of the devices like scintillation cell is normally used in high activity concentration, whereas, device like LLRDS is used in low activity concentration range. All these above devices are used in ambient mode in which air sample is either collected in a cell or in a chamber and the alpha counts are recorded after a definite delay. In some device, air is allowed to be diffused through a filter and alpha activity is estimated using proper detection system. Passive radon dosimeters can effectively be used both in low and high activity concentration range. The cumulative radon exposure can be assessed using passive radon dosimeters. For in situ performance evaluation an area is required where both high and low level activity concentration of radon is anticipated. Uranium mines exhaust area is presumed to be an area where both these conditions can be found by mere variation in the placement of the device. Inter comparison exercise can also be done effectively at this location using various devices of radon estimation

  6. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation

    International Nuclear Information System (INIS)

    Berico, M.; Castellani, C. M.; Formignani, M.; Mariotti, F.

    2001-01-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F e q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F e q, f p ) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented [it

  7. Evaluating radon loss from water during storage in standard PET, bio-based PET, and PLA bottles

    International Nuclear Information System (INIS)

    Lucchetti, Carlo; De Simone, Gabriele; Galli, Gianfranco; Tuccimei, Paola

    2016-01-01

    Polyethylene terephthalate (PET) and polylactic acid (PLA) bottles were tested to evaluate radon loss from water during 15 days of storage. PET bottles (lower surface/volume-ratio vials) lost 0.4–7.1% of initial radon, whereas PLA bottles lost 3.7% of it. PET bottles with volume of 0.5 L, lower surface/weight ratio, and hence higher thickness display proportionally reduced radon loss. Corrections for dissolved radium are needed during analyses. Formulas for calculating degassing efficiency and water interference on electrostatic collections are developed. - Highlights: • Radon loss from water during storage in polyethylene terephthalate (PET) and polylactic acid (PLA) bottles was evaluated. • Surface/volume ratio and thickness of plastic materials were studied. • A correction for dissolved radium concentration was applied to estimate gas loss. • Proper corrections for degassing efficiency of aerators were developed. • The interference of H 2 O on radon daughter electrostatic collection was quantified.

  8. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  9. Radon in balneology - measurement of radon retention by patients and radiation protection for personell

    International Nuclear Information System (INIS)

    Just, G.; Falkenbach, A.; Grunewald, W.A.; Philipsborn, H. von

    2001-01-01

    In radon balneology patients are exposed to radon either from water or air through the skin or through inhalation. Drinking radon water was not included in the study. Previously, the radon transfer has been determined for an estimate of the medically active amount of radon retained in the patient. A simpler approach of measuring radon in expiration under and after exposure has now been standardised and applied to probands under different conditions of exposure. In addition, radon decay products were measured in sweat, saliva and in the skin. Experimental parameters were evaluated for a comparison of different concentrations observed under different conditions. Results are likely to improve both therapy for patients and radiation protection for members of the personnel. (orig.) [de

  10. Contribution to the improvement of radon risk evaluation in Spain

    International Nuclear Information System (INIS)

    Ortega, X.; Vargas, A.

    2002-01-01

    The 96/29/Euratom Directive aims to introduce radon regulation at working places in European Countries. Within the framework, the Spanish Nuclear Regulatory Body, the Nuclear Safety Council (CSN), is interested in obtaining a reliable level of quality for radon measurements in Spain. The radon laboratory group at the Institute of Energetic Techniques of the Technical University of Catalonia in Barcelona (INTE) has been commissioned to adequate its radon chamber for testing radon instruments using standards as IEC 61577 and ISO 13466

  11. Evaluation of the open vial method in the radon measurement

    International Nuclear Information System (INIS)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.

    2014-10-01

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  12. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  13. Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    Science.gov (United States)

    Gross, Eliza L.

    2017-05-11

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont

  14. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  15. Ground-truthing predicted indoor radon concentrations by using soil-gas radon measurements

    International Nuclear Information System (INIS)

    Reimer, G.M.

    2001-01-01

    Predicting indoor radon potential has gained in importance even as the national radon programs began to wane. A cooperative study to produce radon potential maps was conducted by the Environmental Protection Agency (EPA), U.S. Geological Survey (USGS), Department of Energy (DOE), and Lawrence Berkeley Laboratory (LBL) with the latter taking the lead role. A county-wide predictive model based dominantly on the National Uranium Resource Evaluation (NURE) aerorad data and secondly on geology, both small-scale data bases was developed. However, that model breaks down in counties of complex geology and does not provide a means to evaluate the potential of an individual home or building site. Soil-gas radon measurements on a large scale are currently shown to provide information for estimating radon potential at individual sites sort out the complex geology so that the small-scale prediction index can be validated. An example from Frederick County, Maryland indicates a positive correlation between indoor measurements and soil-gas data. The method does not rely on a single measurement, but a series that incorporate seasonal and meteorological considerations. (author)

  16. Certain problems about radon. Pt.1

    International Nuclear Information System (INIS)

    Wu Huishan

    2005-01-01

    Discussion has been made on certain pointed out problems which presently influence the work and development of radon survey, and certain specific problems have been put forward which should be paid much attention and taken measures. Among the problems, some come from cognition, i.e. two kinds of balance and examination about radon, chief culprit of radon's daughter, multiply control and migration, the significance of radon in the water and soil, important standards for designing and evaluating the sites of construction projects, thoughts on the mechanism of the harm of radon and its daughters, diseases causing of both high and low radon, difficulty of emanation of indoor radon, normal low radon from natural marble; and others must be resolved specifically, i.e. establishment of national radon standards as quickly as possible, improvement of on-the-spot examination technique, national-wide radon survey with multiple disciplines and technology, the research on the mechanism of radon's harm and the establishment national radon study center. (authors)

  17. Technical evaluation of a radon daughter continuous monitor in an underground uranium mine

    International Nuclear Information System (INIS)

    Bigu, J.; Grenier, M.

    1982-07-01

    An evaluation of a radon daughter monitor was carried out in an underground uranium mine. The monitor operates on continuous sampling and time integrating principles. Experimental and theoretical data were compared. Experimental results show that the monitor underestimates the Working Level, a fact which is partly attributed to plate-out of decay products in the monitor sampling head. However, a correction factor experimentally determined by standard calibration procedures can be programmed into the monitor to take into account losses by plate-out and other losses. Although the monitor was originally designed for radon daughters, it can equally be used in thoron daughter atmospheres and radon daughter/thoron daughter mixtures such as those encountered in some Canadian uranium mines. An analytical procedure is outlined to allow the calculation of Working Levels in radon daughter/thoron daughter atmospheres from the monitor α-count rate. The memory capability of the monitor should make it quite useful and flexible in underground and surface environments in the uranium mining industry

  18. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  19. Evaluation of genetic alteration induced by radon gas using the micronucleus test (Tradescantia sp. clone KU-20)

    International Nuclear Information System (INIS)

    Bruschi, Armando L.; Azevedo, Heliana de; Macacini, Jose F.; Roque, Claudio V.

    2011-01-01

    The first observations over the existence of radon gas (Rn), initially known as 'thorium emanation', were carried out between the end of 19 th and beginning of 20 th centuries. A result of uranium-238 (U 238 ) radioactive decay, radon is a tasteless, odorless and colorless gas under room temperature, with a 3.825-day half life and particle α emission in its decay, and as final product of its disintegration, the stable lead-206 isotope (Pb 206 ). Being it is the gas with the highest density known, closed and poor ventilated environments are favorable to its accumulation, with its inhalation being the highest health risk. The use of vegetal bioindicators has shown to be excellent on the monitoring of air quality and on mutagenic potential of various pollutants contained in the atmosphere. Within this context, the objective of this study was to evaluate the micronucleus test application potential utilizing the Tradescantia sp. clone KU-20, in order to evaluate genetic alterations induced by radon gas. Stems of Tradescantia sp. clone KU-20, previously immerse in Hoagland solution, were introduced in a radon detection equipment's calibration chamber (Alphaguard), containing radium salt. Afterwards, the accommodated stems were exposed to radon gas (the average radon concentration was 7.639 KBq/m3) for 24 hours. The results demonstrated an increase on micronucleus formation (39.23 + 2.143 MCN/100 tetrads) in stems exposed in relation to the negative control (18.00 + 1.396 MCN/100 tetrads). The difference between the values indicated a significant increase on micronucleus frequency in the inflorescences subjected to radon gas. The presented results demonstrated the micronucleus test application potential using Tradescantia clone KU-20 to evaluate genetic effects induced by radon gas. (author)

  20. Continuous measurements of soil radon under regular field conditions

    International Nuclear Information System (INIS)

    Font, LL

    1999-01-01

    Continuous soil radon measurements were performed in the frame of an European Community-radon network using the Clipperton II detector. It has been found that in some periods, soil radon levels obtained with one Clipperton II probe are very different from those obtained with another probe placed at the same depth but a short distance apart. It has been also found that the response of the probes to a sudden change of radon concentration is controlled by the diffusion process along the bottom tube of the probe. Therefore, this study shows that the experimental data can be attributed to the natural behaviour of soil radon

  1. RADON AND CARCINOGENIC RISK IN MOSCOW

    Directory of Open Access Journals (Sweden)

    S. M. Golovanev

    2015-01-01

    Full Text Available Objective: comparative evaluation of carcinogenic risk inMoscowfrom radon in indoor and atmospheric pollutants.Materials and methods: the lung cancer incidence in Moscow; radiation-hygienic passport of the territory; .U.S. EPA estimated average age at all and radon induced deaths, years of life lost; Report of UNSCEAR 2006 and WHO handbook on indoor radon, 2009. Trend analysis of incidence; evaluation of the excess relative risk; assessment of ratio radon-induced population risk and published values оf total population carcinogenic risk from chemical carcinogens.Results: it is shown that the 304 cases of lung cancer per year (1. 85 10-3 on average from 2006 to 2011 (21280diseases for 70 years in addition to background level induced by radon; the differences in average trends of all lungcancer incidence in the districts can exceed 25%.Conclusion. The potential of risk reduction by measures of mitigation radon concentration exceeds 5 times the cost efficiency to reduce emissions from vehicles and can reduce cancer incidence, on average 236 cases per year; population risk 16520 cases over 70 years or save not less than 2832 person-years of life per year. The annual effect of reducing losses from not-survival of 12 years as a result of radon-induced lung cancer deaths exceeds 14160000 dollars. The evaluating of the carcinogenic risk from radon in accordance with the definition of population risk increases the predictive evaluation of the effectiveness of preventive measures more than twice.

  2. Evaluation of tectonic impact on radon level of lithological units

    International Nuclear Information System (INIS)

    Wolkowicz, S.; Strzelecki, R.

    2000-01-01

    The radon potential maps of the Sudetes Mountains and Upper Silesian Coal Basin have been prepared on a base of arithmetic mean value of radon concentration in soil air in distinguished lithological/stratigraphic units. Both zones of shallow position of ground table and the fault zones influence value of this parameter: the first one affects in specific conditions lowering of background values, the second ones - origin of values several and teen times higher than rock background values. Estimation of power of tectonic influence on general radon potential of the lithological units has been made on a base of examination of histograms of distribution of radon concentration in soil air. In the Sudetes area, 0 % to about 30 % of the measurements is related to fault zones. Higher tectonic engagement (about 30 %) characterizes the Karkonosze Granites, Izera Gneisses and Strzegom Granites. In the cases of Karkonosze Granites and the Strzegom Granites, rock background values concentrations in soil air are a little than 50 kBq/m 3 , what is the value defined for lower threshold of high radon risk areas. In conclusion, presence of numerous fault zones and fissures increases radon risk category with one class. Background modal values of radon emanations, defined for the studied units, in the 5 cases fulfill criteria for medium radon risk areas, and in other cases do not exceed of the threshold 10 kBq/m 3 . It displays, that in the case of low radon potential rocks only a few-percent rich population of measurements related to tectonic zones, is sufficient to substantially deform of the image of the studied unit radon potential. For instance, medium radon potential characterizes the Klodzko - Zloty Stok Granites (the arithmetic mean value of this class is 36.15 kBq/m 3 , n=104) and small tectonic engagement (about 3.8 %). In the result the modal value belongs to the class 20-30 kBq/m 3 . The Poreba Beds in the Upper Silesian Coal Basin are characterised by almost the same radon

  3. Characteristic behavior of water radon associated with Wenchuan and Lushan earthquakes along Longmenshan fault

    International Nuclear Information System (INIS)

    Ye, Qing; Singh, Ramesh P.; He, Anhua; Ji, Shouwen; Liu, Chunguo

    2015-01-01

    In China, numerous subsurface, surface water well and spring parameters are being monitored through a large network of stations distributed in China sponsored by China Earthquake Administration (CEA). All the data from these network is managed by China Earthquake Network Center (CENC). In this paper, we have used numerous data (water radon, gas radon, water level, water temperature) available through CENC for the period 2002–2014 and studied the behavior and characteristics of water 222 radon [Rn(w)]. The observed parameters were also complemented by rainfall data retrieved from Tropical Rainfall Measuring Mission (TRMM) satellite. Our detailed analysis shows pronounced changes in the observed parameters (especially water and gas radon) prior to the earthquake. The changes in water radon, ground water level and rainfall showing characteristics behavior for Wenchuan and Lushan earthquakes. The long term data analysis of water radon and water level at various locations around epicenters of two major earthquakes along Longmenshan fault show a positive and negative relation of water radon and water level prior to these earthquakes. It is difficult to find any trend of water radon and changes in water radon pattern with these two earthquakes that could prove as a reliable precursor of earthquakes. Changes in the water radon concentrations from one location to other may be associated with the changes in ground water regime and geological settings in the epicentral and surrounding regions. - Highlights: • Long trend of water radon measured in China during 2003–2014 at six stations round Longmenshan fault. • Water radon shows characteristics behavior associated with Wenchuan and Lushan earthquakes. • Water radon shows one to one relation with rainfall and ground water level variations. • Sharp increase or decrease in water radon concentrations are found few days prior to the earthquake

  4. A calibration facility for radon fluxmeter

    International Nuclear Information System (INIS)

    Li Xianjie; Qiu Shoukang; Zhou Jianliang; Liu Chunkui; Pan Jialin; Yang Mingli

    1998-01-01

    Calibration facilities for radon fluxmeter with three kinds of different emanation medium have been developed. The stability of radon flux is 5%, 9% (RSD) respectively. The uniformity of radon flux is 4.5%, 8.5% (RSD) respectively. These specifications fulfill the calibration requirement for radon fluxmeter. The determination of radon flux of facility takes full account of eliminating the main error source-attenuation effect (including leakage and back diffusion etc.): not only prevent attenuation and make a relevant correction. Therefore the accuracy of determination is assured. The calibration, intercomparison of radon flux meter and the quantitatively evaluation on the measurement method of radon flux are made to be possible by the successful establishment of this facility. (author)

  5. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  6. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  7. Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose

    Science.gov (United States)

    Rabi, R.; Oufni, L.

    2018-04-01

    The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.

  8. Field evaluation and health assessment of air cleaners in removing radon decay products in domestic environments

    International Nuclear Information System (INIS)

    Li, Chih-Shan.

    1990-01-01

    In this study, field evaluations of two types of air cleaners were conducted in three single-family houses. The measurements included radon concentration, particle number concentration, and concentration and size distribution of radon decay products. The influence on the behavior of radon decay products by various indoor particles both with and without the air cleaning systems was investigated. A room model was used to calculate the changes in the aerosol parameters caused by the operation of the air cleaners. Using the James dosimetric models (1989 and 1990), the changes in the hourly bronchial dose rate per Bq m -3 radon for men, women, and children can be estimated for various domestic environments. 94 refs., 60 figs., 28 tabs

  9. Radon in large buildings

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the U.S. Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed. (orig.). (5 refs., 3 figs.)

  10. Radon concentration and natural radioactivity evaluation in the Vysehrad casemates

    International Nuclear Information System (INIS)

    Berka, Z.; Thinova, L.; Stepan, M.

    2004-01-01

    The Vysehrad casemates formed a part of Prague's defense system in the middle ages. The casemates consist of a large system of underground corridors (which are in direct contact with subsoils) that run around the whole Vysehrad hill. The corridors are covered by an artificially made-up ground. Although there are many vents and embrasures in the casemates, investigation of radon accumulation in the casemates is of interest. A comprehensive radon and natural radioactivity survey has been carried out on the Vysehrad hill as part of special scientific programme for secondary school students. No extreme radon concentration or extremely high natural radioactivity has been observed. The highest radon concentration were measured in the blind parts of corridors that are normally unused. The radon concentrations found can be described as health-safe

  11. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  12. Radon thematic days - Conference proceedings

    International Nuclear Information System (INIS)

    2011-03-01

    This document brings together the available presentations given at the Radon thematic days organized by the French society of radiation protection (SFRP). Twenty five presentations (slides) are compiled in the document and deal with: 1 - General introduction about radon (Sebastien Baechler, IRA); 2 - Survey of epidemiological studies (Dominique Laurier, IRSN); 3 - Dosimetric model (Eric Blanchardon, Estelle Davesne, IRSN); 4 - Radon issue in Franche-Comte: measurement of the domestic exposure and evaluation of the associated health impact (Francois Clinard, InVS); 5 - WHO's (World Health Organization) viewpoint in limiting radon exposure in homes (Ferid Shannoun, OMS); 6 - Radon measurement techniques (Roselyne Ameon, IRSN); 7 - Quality of radon measurements (Francois Bochud, IRA); 8 - International recommendations (Jean-Francois Lecomte, IRSN); 9 - Radon management strategy in Switzerland - 1994-2014 (Christophe Murith, OFSP); 10 - 2011-2015 action plan for radon risk management (Jean-Luc Godet, Eric Dechaux, ASN); 11 - Radon at work place in Switzerland (Lisa Pedrazzi, SUVA); 12 - Strategies of radiation protection optimization in radon exposure situations (Cynthia Reaud, CEPN); 13 - Mapping of the radon potential of geologic formations in France (Geraldine Ielsch, IRSN); 14 - Radon database in Switzerland (Martha Gruson, OFSP); 15 - Radon 222 in taps water (Jeanne Loyen, IRSN); 16 - Buildings protection methods (Bernard Collignan, CSTB, Roselyne Ameon, IRSN); 17 - Preventive and sanitation measures in Switzerland (Claudio Valsangiacomo, SUPSI); 18 - Training and support approach for building specialists (Joelle Goyette-Pernot, Fribourg engineers and architects' school); 19 - Status of radon bulk activity measurements performed between 2005-2010 in public areas (Cyril Pineau, ASN); 20 - Neuchatel Canton experiments (Didier Racine, SENE); 21 - Montbeliard region experience in the radon risk management (Isabelle Netillard, Pays de Montbeliard Agglomeration); 22

  13. Radon in workplaces: First results of an extensive survey and comparison with radon in homes

    International Nuclear Information System (INIS)

    Bucci, S.; Pratesi, G.; Viti, M. L.; Pantani, M.; Bochicchio, F.; Venoso, G.

    2011-01-01

    Extensive radon surveys have been carried out in many countries only in dwellings, whereas surveys in workplaces are rather sparse and generally restricted to specific workplaces/activities, e.g. schools, spas and caves. Moreover, radon-prone areas are generally defined on the basis of radon surveys in dwellings, while radon regulations use this concept to introduce specific requirements in workplaces in such areas. This approach does not take into account that work activities and workplace characteristics can significantly affect radon concentration. Therefore, an extensive survey on radon in different workplaces have been carried out in a large region of Italy (Tuscany), in order to evaluate radon distribution in workplaces over the whole territory and to identify activities and workplace characteristics affecting radon concentration. The results of this extensive survey are compared with the results of the survey carried out in dwellings in the same period. The workplaces monitored were randomly selected among the main work activities in the region, including both public and industrial buildings. The survey monitored over 3500 rooms in more than 1200 buildings for two consecutive periods of ∼6 months. Radon concentration was measured by means of passive nuclear track detectors. (authors)

  14. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  15. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  16. Communicating radon risk effectively: Radon testing in Maryland. Final report

    International Nuclear Information System (INIS)

    Desvousges, W.H.; Smith, V.K.; Rink, H.H.

    1988-10-01

    Two sets of materials and corresponding delivery strategies for communicating radon risk were evaluated, compared with a 'no-special-treatment' strategy in a comparison community. One community received radio public-service announcements and utility bill inserts. The second received these plus posters, local government sponsorship of a radon awareness week, and local slide presentations. The most-intensive efforts (multiple channels, multiple hits) were more effective than the less intensive effort, which had little impact compared with no special treatment. From a marketing perspective, the effort was very successful, increasing the share of homeowners who tested for radon from 5% to 15%. This may not be viewed as sufficiently effective from a public-health perspective, however

  17. Evaluation of the open vial method in the radon measurement; Evaluacion del metodo del vial abierto en la medicion de radon

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  18. Cost effectiveness of radon mitigation in Canada

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Krewski, D.; Zielinski, J.M.; McGregor, R.G.

    1992-01-01

    This paper examines the cost effectiveness of comprehensive strategies for reducing exposure to radon gas in indoor air in Canadian homes. The analysis is conducted within the context of a general framework for risk management programme evaluation which includes well-known evaluation techniques such as cost effectiveness and cost-benefit analyses as special cases. Based on this analysis, it is clear that any comprehensive programme to reduce exposure to environmental radon will be extremely expensive, and may not be justifiable in terms of health impact, particularly when considered in relation to other public health programmes. Testing of homes at the point of sale and installing sub-slab suction equipment to reduce exposure to indoor radon where necessary appears to be a relatively cost-effective radon mitigation strategy. In general, radon mitigation was found to be most cost effective in cities with relatively high levels of radon. (author)

  19. Indoor radon risk potential of Hawaii

    International Nuclear Information System (INIS)

    Reimer, G.M.; Szarzi, S.L.

    2005-01-01

    A comprehensive evaluation of radon risk potential in the State of Hawaii indicates that the potential for Hawaii is low. Using a combination of factors including geology, soils, source-rock type, soil-gas radon concentrations, and indoor measurements throughout the state, a general model was developed that permits prediction for various regions in Hawaii. For the nearly 3,100 counties in the coterminous U.S., National Uranium Resource Evaluation (NURE) aerorad data was the primary input factor. However, NURE aerorad data was not collected in Hawaii, therefore, this study used geology and soil type as the primary and secondary components of potential prediction. Although the radon potential of some Hawaiian soils suggests moderate risk, most houses are built above ground level and the radon soil potential is effectively decoupled from the house. Only underground facilities or those with closed or recirculating ventilation systems might have elevated radon potential. (author)

  20. Radon

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Anorganische Chemie

    1978-09-01

    The noble gas radon, formerly called emanation, was discovered a few years after radium. /sup 222/Rn, the longest-lived isotope, has a half-life of 3,82 days. This half life is so short that the experimental techniques available at present (1978) are not sufficient for a characterization of defined radon compounds, even though there are definite indications for the existence of such compounds, and one may expect such radon compounds to be even more stable than the numerous known xenon compounds. - The radon isotopes /sup 219/Rn (Actinon), /sup 220/Rn (Thoron), and /sup 222/Rn (Radon) occur in nature despite their rather short half-lives, because they are continously generated from their mothers /sup 223/Ra, /sup 224/Ra, and /sup 226/Ra, which are in secular equilibrium with long-lived isotopes /sup 235/U, /sup 238/U, and /sup 232/Th, and are in turn continously formed from these long-lived isotopes. Since the radon isotopes are gases, they enter the atmosphere and are carried for long distances with air currents. - Because radon is so short-lived, its practical applications are rather limited. For medical applications, small sealed glass tubes filled with radon are used as radiation sources after the radon has decayed, because the whole series of Po-, Bi-, and Pb-isotopes of the radium decay chain are formed, whose penetrating radiation is useful for therapy. When solids are spiked with Ra isotopes, radon is evolved at a constant rate. On heating such solids, phase transitions show up by sudden increased radon evolution (Hahn's emanation method). - On the basis of nuclear theoretical calculations, there is hardly a chance for the discovery of a long-lived radon species. Therefore, major progress in radon chemistry is hardly to be expected in the near future.

  1. Quantitative evaluation of the lung cancer deaths attributable to residential radon: A simple method and results for all the 21 Italian Regions

    International Nuclear Information System (INIS)

    Bochicchio, F.; Antignani, S.; Venoso, G.; Forastiere, F.

    2013-01-01

    Pooled analyses of epidemiological case-control studies on lung cancer and residential radon have shown that radon exposure in dwellings increases lung cancer risk, and that the increase is statistically significant also for prolonged exposures to low-medium level of radon concentration, i.e. levels commonly found in many dwellings. In this paper, a simple method to evaluate the health burden due to the presence of radon in homes (i.e. the number of lung cancer deaths attributable to radon exposure in dwellings) was presented. This method is based on the following parameters: i) the excess relative risk per unit of exposure evaluated in case-control studies; ii) the average radon concentration that can be considered representative of population exposure in dwellings; iii) the total number of lung cancer deaths occurring each year. Moreover, the interaction between radon and cigarette smoking is needed to be taken into account: in fact, although most of the persons are non-smokers, most of the lung cancer deaths attributed to radon are actually due to the multiplicative effect of radon and cigarette smoking. To show this effect, the number of radon related lung cancer deaths estimated to occur among current, former and never smokers was calculated separately for males and females, taking into account the relative risk of lung cancer for the different smoking categories and the prevalence of smoking habits. The methodology described in this work was applied to all the 21 Italian Regions in order to illustrate it. The overall fraction of lung cancer deaths attributable to radon in Italy is about 10%, with values in individual Regions ranging from 4% to 16%. The greater part of the lung cancers attributable to radon is estimated to occur among current smokers for both males and females (72% and 60%, respectively, at national level). This is due to the synergistic effects of radon and cigarette smoking, which should therefore be taken into account in policies aimed to

  2. Radon availability in New Mexico

    International Nuclear Information System (INIS)

    McLemore, V.T.

    1995-01-01

    The New Mexico Bureau of Mines and Mineral Resources (NMBMMR) in cooperation with the Radiation Licensing and Registration Section of the New Mexico Environment Department (NMED) and the US Environmental Protection Agency (EPA) have been evaluating geologic and soil conditions that may contribute to elevated levels of indoor radon throughout New Mexico. Various data have been integrated and interpreted in order to determine areas of high radon availability. The purpose of this paper is to summarize some of these data for New Mexico and to discuss geologic controls on the distribution of radon. Areas in New Mexico have been identified from these data as having a high radon availability. It is not the intent of this report to alarm the public, but to provide data on the distribution of radon throughout New Mexico

  3. Radon flux measurement methodologies

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.

    1984-01-01

    Five methods for measuring radon fluxes are evaluated: the accumulator can, a small charcoal sampler, a large-area charcoal sampler, the ''Big Louie'' charcoal sampler, and the charcoal tent sampler. An experimental comparison of the five flux measurement techniques was also conducted. Excellent agreement was obtained between the measured radon fluxes and fluxes predicted from radium and emanation measurements

  4. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  5. Biological effects of radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A E; Tavera D, L; Cruces M, M P; Arceo M, C; Rosa D, M.E. de la

    1992-04-15

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  6. Biological effects of radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A.E.; Tavera D, L.; Cruces M, M.P.; Arceo M, C.; Rosa D, M.E. de la

    1992-04-15

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  7. Health effects of radon

    International Nuclear Information System (INIS)

    Easterly, C.

    1994-01-01

    Exposure of people to radon has taken on increased interest during the last decade because of the understanding that buildings can serve to trap radon and its daughters, and thereby build up undesirable concentrations of these radioactive elements. Numerous studies of underground miners (often uranium miners) have shown an increased risk of lung cancer in comparison with nonexposed populations. Laboratory animals exposed to radon daughters also develop lung cancer. The abundant epidemiological and experimental data have established the carcinogenicity of radon progeny. Those observations are of considerable importance, because uranium, from which radon and its progeny arise, is ubiquitous in the earth's crust, including coal mines. Risk estimates of the health effects of long-term exposures at relatively low levels require continued development, especially to address the potential health effects of radon and radon daughters in homes and occupational settings where the exposure levels are less than levels in underground uranium and other metal mines that have been the subject of epidemiological studies. Two approaches can be used to characterize the lung-cancer risks associated with radon-daughter exposure: mathematical representations of the respiratory tract that model radiation doses to target cells and epidemiological investigation of exposed populations, mainly underground uranium miners. The mathematically-based dosimetric approach provides an estimate of lung cancer risk related to radon-daughter exposure based specifically on modeling of the dose to target cells. The various dosimetric models all require assumptions, some of which are not subject to direct verification, as to breathing rates; the deposition of radon daughters in the respiratory tract; and the type, nature, and location of the target cells for cancer induction. The most recent large committee effort drawn together to evaluate this issue was sponsored by the National Research Council

  8. Locating and limiting radon in dwellings

    International Nuclear Information System (INIS)

    Hildingson, O.; Gustafsson, J.; Nilsson, I.

    1984-01-01

    More than 3,300 Swedish dwellings have an indoor radon daughter concentration above 400 Bq.m -3 (or 0.108 WL). It is considered to be unsafe to live in any of these dwellings and the radon daughter concentration has to be reduced. Before deciding what measures to take, it is important to determine the radon sources. Possible sources are exhalation from building materials and/or radon transport from the ground into the building through cracks and joints in the slab. Different methods of locating the sources have been developed. To locate cracks and joints in slabs the ventilation rate and the air pressure difference relative to the ground are changed while monitoring radon/radon daughter concentration. The effect of five different measures to reduce the indoor radon daughter concentration have also been evaluated: increased ventilation rate by mechanical ventilation, ventilation of the small spaces between the floor and the slab, sealing the surface of radon exhaling walls, sealing joints and cracks in the slab, and ventilation of the drainage under the slab. (author)

  9. Comparative study of radon in Sudan

    International Nuclear Information System (INIS)

    Gharbi, Shaza Ismail Mohammed

    2014-07-01

    This study was conducted primarily to contribute radon data for radon map in Sudan and identify regions with elevated radon levels and improve data collection and analysis for the future radon levels evaluation. This study partially covered three states of Sudan ( Red Sea - Khartoum - South Khordofan). Previous work done has been considered in this study which focused and investigated the levels of radon concentration in ( indoor radon gas and water) by using gamma spectrometry equipped with ( HPGe detector) or (Na1 (T1) detector). The results obtained are within the acceptable levels and dose not poses any risk from radiation protection point of view. Red Sea state ( port-sudan): (124.39±6.21) Bq/m 3 . Khartoum state ( Suba): (151.52) Bq/m 3 . (Omdurman): ( 127±23) Bq/m 3 . Radon in water: (59) Bq/L. South Kordofan State: (102.8) Bq/m 3 . In water (Kadugli): (3 1 39)) Bq/L.(Author)

  10. Radon anomalies and their correlation with microseismicity in N-W Himalaya

    International Nuclear Information System (INIS)

    Virk, H.S.; Walia, Vivek; Sharma, Anand Kumar; Kumar, Naresh; Kumar, Rajiv

    2000-01-01

    Evidence for radon anomalies in soil-gas and groundwater as earthquake precursor phenomenon is recorded in Kangra and Chamba valleys of Himachal Pradesh, India based on micro-seismicity trends in N-W Himalaya. Radon monitoring is being carried out at Palampur, Jawalamukhi, Dalhousie and Chamba stations using emanometry for discrete measurements and alpha-logger technique for continuous recording of time-series radon data from June 1996 to September 1997. Radon anomalies in both type of data are correlated with some of the micro-earthquakes recorded during the time-window by the seismographic network of Indian Meteorological Department (IMD). A critical analysis is made of radon data to find confidence level and sensitivity of each recording station

  11. Final report of evaluation of dose and measurement of radon concentration

    International Nuclear Information System (INIS)

    1998-03-01

    A mean annual exposure to radon daughters in indoor air was estimated on the basis of measurement of radon concentration in indoor air in Japan from fiscal 1992 to 1996. Doses were estimated by UNSCEAR method. The representative values in this report show the mean values in whole Japan. Each dose in the local area was different reflecting the different concentration of radon daughters. However, the same parameters were used in each area. When mean annual dose of radon daughters was estimated, we used 15.5 Bq m -3 mean annual exposure to radon daughters in indoor air, 5 Bq m -3 that in outdoor air, 0.4 the equilibrium factor indoor, 0.6 the equilibrium factor outdoor and 0.9 of P. The model of UNSCEAR based on these above values gave 0.46 mSv y -1 mean annual dose of radon daughters which were consisted of from 0.38 mSv y -1 in Kanto district to 0.52 mSv y -1 Kyushu, Okinawa district. (S.Y.)

  12. Final report of evaluation of dose and measurement of radon concentration

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    A mean annual exposure to radon daughters in indoor air was estimated on the basis of measurement of radon concentration in indoor air in Japan from fiscal 1992 to 1996. Doses were estimated by UNSCEAR method. The representative values in this report show the mean values in whole Japan. Each dose in the local area was different reflecting the different concentration of radon daughters. However, the same parameters were used in each area. When mean annual dose of radon daughters was estimated, we used 15.5 Bq m{sup -3} mean annual exposure to radon daughters in indoor air, 5 Bq m{sup -3} that in outdoor air, 0.4 the equilibrium factor indoor, 0.6 the equilibrium factor outdoor and 0.9 of P. The model of UNSCEAR based on these above values gave 0.46 mSv y{sup -1} mean annual dose of radon daughters which were consisted of from 0.38 mSv y{sup -1} in Kanto district to 0.52 mSv y{sup -1} Kyushu, Okinawa district. (S.Y.)

  13. Radon

    Science.gov (United States)

    ... radon-resistant features. These features include gravel and plastic sheeting below the foundation, along with proper sealing ... lower the radon level. Detailed information about radon reduction in your home or building can be found ...

  14. Earthquake forecasting studies using radon time series data in Taiwan

    Science.gov (United States)

    Walia, Vivek; Kumar, Arvind; Fu, Ching-Chou; Lin, Shih-Jung; Chou, Kuang-Wu; Wen, Kuo-Liang; Chen, Cheng-Hong

    2017-04-01

    For few decades, growing number of studies have shown usefulness of data in the field of seismogeochemistry interpreted as geochemical precursory signals for impending earthquakes and radon is idendified to be as one of the most reliable geochemical precursor. Radon is recognized as short-term precursor and is being monitored in many countries. This study is aimed at developing an effective earthquake forecasting system by inspecting long term radon time series data. The data is obtained from a network of radon monitoring stations eastblished along different faults of Taiwan. The continuous time series radon data for earthquake studies have been recorded and some significant variations associated with strong earthquakes have been observed. The data is also examined to evaluate earthquake precursory signals against environmental factors. An automated real-time database operating system has been developed recently to improve the data processing for earthquake precursory studies. In addition, the study is aimed at the appraisal and filtrations of these environmental parameters, in order to create a real-time database that helps our earthquake precursory study. In recent years, automatic operating real-time database has been developed using R, an open source programming language, to carry out statistical computation on the data. To integrate our data with our working procedure, we use the popular and famous open source web application solution, AMP (Apache, MySQL, and PHP), creating a website that could effectively show and help us manage the real-time database.

  15. Standardised Radon Index (SRI: a normalisation of radon data-sets in terms of standard normal variables

    Directory of Open Access Journals (Sweden)

    R. G. M. Crockett

    2011-07-01

    Full Text Available During the second half of 2002, from late June to mid December, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in the English East Midlands. This period included the Dudley earthquake (ML = 5, 22 September 2002 and also a smaller earthquake in the English Channel (ML = 3, 26 August 2002. Rolling/sliding windowed cross-correlation of the paired radon time-series revealed periods of simultaneous similar radon anomalies which occurred at the time of these earthquakes but at no other times during the overall radon monitoring period. Standardising the radon data in terms of probability of magnitude, analogous to the Standardised Precipitation Indices (SPIs used in drought modelling, which effectively equalises different non-linear responses, reveals that the dissimilar relative magnitudes of the anomalies are in fact closely equiprobabilistic. Such methods could help in identifying anomalous signals in radon – and other – time-series and in evaluating their statistical significance in terms of earthquake precursory behaviour.

  16. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  17. Indoor Air '93. Particles, microbes, radon

    International Nuclear Information System (INIS)

    Kalliokoski, P.; Jantunen, M.; Seppaenen, O.

    1993-01-01

    The conference was held in Helsinki, Finland, July 4-8, 1993. The proceedings of the conference were published in 6 volumes. The main topics of the volume 5 are: (1) particles, fibers and dust - their concentrations and sources in buildings, (2) Health effects of particles, (3) Need of asbestos replacement and encapsulation, (4) Seasonal and temporal variation of fungal and bacterial concentration, (5) The evaluation of microbial contamination of buildings, (6) New methods and comparison of different methods for microbial sampling and evaluation, (7) Microbes in building materials and HVAC-systems, (8) Prevention of microbial contamination in buildings, (9) Dealing with house dust mites, (10) Radon measurements and surveys in different countries, (11) The identification of homes with high radon levels, (12) The measurement methods and prediction of radon levels in buildings, and (13) Prevention of radon penetration from the soil

  18. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  19. Radon in Schools

    Science.gov (United States)

    ... Search Search Radon Contact Us Share Radon in Schools Related Information Managing Radon in Schools Radon Measurement ... Radon Could Be a Serious Threat to Your School Chances are you've already heard of radon - ...

  20. Theoretical evaluation of indoor radon control using a carbon adsorption system

    International Nuclear Information System (INIS)

    Bocanegra, R.; Hopke, P.K.

    1989-01-01

    The conceptual framework for a carbon-based adsorption system for the control of indoor radon is presented. Based on the adsorptivity of typically available activated carbons, it is shown theoretically that carbon bed adsorbers can be effective in lowering indoor radon levels particularly when the area of radon ingress (the basement) has a relatively low exchange rate with the rest of the house

  1. Measurements of radon and chemical elements: Popocatepetl volcano; Mediciones de radon y elementos quimicos: Volcan Popocatepetl

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Armienta, M.A.; Valdes, C.; Mena, M. [IGFUNAM, Ciudad Universitaria, 04510 Mexico D.F. (Mexico); Seidel, J.L.; Monnin, M. [UMR 5569 CNRS Hydrosciences, Montpellier (France)

    2002-07-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  2. Radon-technical design methods based on radon classification of the soil

    International Nuclear Information System (INIS)

    Kettunen, A.V.

    1993-01-01

    Radon-technical classification of the foundation soil divides the foundation soil into four classes: negligible, normal, high and very high. Separate radon-technical designing methods and radon-technical solutions have been developed for each class. On regions of negligible class, no specific radon-technical designing methods are needed. On regions of normal radon class, there is no need for actual radon-technical designing based on calculations, whereas existing radon-technical solutions can be used. On regions of high and very high radon class, a separate radon-technical designing should be performed in each case, where radon-technical solutions are designed so that expected value for indoor radon content is lower than the maximum allowable radon content. (orig.). (3 refs., 2 figs., 2 tabs.)

  3. Sign of Radon for locate geothermic sources

    International Nuclear Information System (INIS)

    Gonzalez Teran, D.

    1991-01-01

    Evaluation of a geothermic field is based upon geological, geophysical and geochemical studies that enable the evaluation of the deposit potential, that is to say, the amount of energy per unit mass, the volume of the trapped fluid, vapor fraction and fluid chemistry. This thesis has as its objective the evaluation of radon gas emanation in high potential geothermic zones in order to utilize the results as a low cost and easy to manage complimentary tool in geothermic source prospection. In chapter I the importance and evaluation of a geothermic deposit is discussed. In chapter II the general characteristics of radon are discussed: its radioactivity and behavior upon diffusion over the earth's surface> Chapter III establishes the approach used in the geothermic field of Los Azufres, Michoacan, to carry out samplings of radon and the laboratory techniques that were used to evaluate the concentration of radon in the subsoil. Finally in chapter IV measurements of radon in the field are compared to geological faults in the area under study. The sampling zones were: low geothermic potential zone of the northern and the southern zone having a greater geothermic potential than that in the north. The study was carried out at different sampling times using plastics detectors of from 30 to 46 days from February to July. From the results obtained we concluded that the emission of radon was greater in the zones of greatest geothermic potential than in the low geothermic potential zones it was also affected by the fault structure and the time of year in which sampling was done. (Author)

  4. Blower door method in radon diagnostics

    International Nuclear Information System (INIS)

    Fronka, A.; Moucka, L.

    2004-01-01

    The idea of the radon transfer factor is commonly presented as the ratio of the building indoor radon concentration to the subsoil radon concentration. Ventilation and the pressure field over the whole building envelope, which varies in a time over a very wide range even in the same building, poses a major problem. Therefore a new approach based on the controlled conditions determining the soil air infiltration was developed. Radon in soil gas infiltrates into the building indoor environment particularly through cracks and other leakages in the structure providing the building contact with its subsoil. The infiltration is driven by the air pressure difference on the two sides of the structure. The pressure difference is caused by the stack effect and its value ranges from 1-2 Pa in family houses to some tens of Pa in higher buildings. Unfortunately, the pressure difference is very unstable under normal conditions, being affected by a host of parameters such as the height of the building, distribution and geometry of leakages, outdoor-indoor temperature difference, etc. Wind direction and velocity of the wind plays a major role. In our research the blower door method was applied in combination with a monitoring of the indoor radon concentration. The indoor-outdoor pressure difference and the pressure difference at the two sides of the screen shutter of the blower door fan are also measured. The blower door ensures a constant, evaluable air exchange rate. The fan power is regulated to provide a stable pressure difference within the range of roughly 5-100 Pa. This approach provides very well defined conditions allowing us to apply a constant ventilation-constant radon supply model. In such circumstances the dynamical changes of radon concentrations are very fast, and therefore a unique continual radon monitor was applied. The radon supply rate is evaluated from the radon steady state of the time course of radon concentration. The dependence of the radon supply rate on

  5. A study on the risk from indoor radon 220 and radon 222 exposures

    International Nuclear Information System (INIS)

    Rannou, A.

    1986-12-01

    The hazards from radon (radon 220 and 222) in dwelling atmospheres have been studied. In the first part devoted to the present state of the problem, an analysis is made of the formation mechanisms and the evolution of radon and its daughters indoors. The main physical and dosimetric quantities required for the risk evaluation are defined. The theoretical and experimental analysis of the methods of measurements of radon and its daughters used in the measurement campaign are considered in the second part. The progress and the result of the national survey are developed in the third part. The effects of several factors on indoor levels are discussed. The conclusions of a particular study in the Finistere ''department'' are presented. The data collected make it possible to assess the mean exposure of man to natural radiation [fr

  6. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  7. The radon influence of SAGE results

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.; Mirmov, I.N.

    2002-01-01

    The method for evaluating systematic errors, connected with radon, is described in the experiment on determining the SAGE solar neutrino flux. The systematic error by the measured neutrino capture rate in the gallium 75 SNU target does not exceed 0.3 SNU. The obtained value (0.3 SNU) is the upper limit of the radon systematic error. Its low value means, that radon does not contribute significantly to the SAGE result [ru

  8. Realization of radioactive equilibrium in the KRISS radon chamber

    International Nuclear Information System (INIS)

    Lee, Mo Sung; Park, Tae Soon; Lee, Jong Man

    2013-01-01

    The maintenance of radioactive equilibrium between radon and its decay products in a radon chamber is necessary to calibrate radon decay product monitors. In this study, the activity concentrations of radon decay products have been measured, and mosquito-repellent incense has been used to produce aerosol particles in the chamber. Filter papers with 8 μm pore size were used to collect aerosol in the chamber. The activity concentrations of radon decay products have been evaluated by the Modified Tsivoglou Method. The correction factors due to the differences in counting time requirements of the Modified Tsivoglou Method and the time delay between consecutive measurements have been determined. Finally, the radioactive equilibrium has been confirmed by applying the Bateman equation. - Highlights: • The activity concentrations of radon decay products are evaluated by the Modified Tsivoglou Method. • Mosquito-repellent incense is used to produce aerosol particles in the radon chamber. • The radioactive equilibrium in the chamber was achieved within 2 days and confirmed by the Bateman equation

  9. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  10. A remote controlled system for continuous radon measurements to realize a monitoring network

    International Nuclear Information System (INIS)

    Roca, V.; Pugliese, M.; Venoso, G.; Roca, V.; Boiano, A.; D'Onofrio, A.; Pugliese, M.; Sabbarese, C.; Venoso, G.; D'Onofrio, A.; Sabbarese, C.

    2006-01-01

    R.A.M.O.N.A. (radon monitoring and acquisition) is a compact system for radon and climatic parameters monitoring. The instrument can perform alpha particles spectrometry with a resolution better than .5 %, so it is possible the discrimination of radon and thoron daughters. The development of battery operated electronics with integrated amplifier and micro controller makes the device applicable for in-lab and in-field measurements. Moreover, an ethernet interface allows to remotely drive the system and the download of acquired data. After a wide use of the prototype in laboratory, a lot of systems has been built and installed in some sites to carry out radon monitoring in soil. (authors)

  11. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  12. THE REPUBLIC OF BELARUS RADON DANGER MAP

    Directory of Open Access Journals (Sweden)

    L. A. Chunikhin

    2016-01-01

    Full Text Available Radon is the major contributor to the background exposure of the population. In the world practice, the radon risk or radon potential mapping are used for the radon dose assessment.The aim of this work was a radon danger mapping of the Republic of Belarus to assess the radiation situation and determine the radon hazard critical areas.Materials and methods: The mapping is based on measured values of radon volume activity in the living rooms of different buildings on the territory of the six regions of the Republic of Belarus. We have performed more than 4000 measurements. Integral track radon radiometers based on the polymer Kodak LR-115 film were used to evaluate radon volume activity. Exposure time ranged from 90 to 120 days. The cartogram was built with using the MAPINFO software package.Results: The low levels of radon concentrations were determined in the Brest and Gomel regions, as well as in the southern districts of Minsk and south-western districts of the Mogilev region. The high levels radon concentrations were determined in some districts of the Vitebsk and Grodno regions, as well as in the north-eastern districts of the Mogilev region. About 2–5 times nonuniformity of radon distribution in settlements of the Republic was observed. The radon hazard critical areas with radon concentrations in the range of 200–400 Bq/m3 were found in some districts of the Vitebsk, Grodno and Mogilev regions.Conclusions: The radon risk map of the Republic of Belarus gives the possibility to estimate the existing radiation risk. Taking into account the low efficiency of countermeasures long after the Chernobyl accident, it is necessary to increase the level of radiation protection through the radon mitigation activities or to change the radon normative documents.

  13. Czech studies of lung cancer and radon

    International Nuclear Information System (INIS)

    Tomasek, L.

    2002-01-01

    According to the International Agency for Research on Cancer, there is a significant evidence to classify radon as a carcinogen. Using extrapolations from occupational studies, it can be shown that for some countries environmental exposure to radon is the second most important cause of lung cancer in the general population after cigarette smoking. Czech studies among uranium miners, established in 1970 by Josef Sevc, and in the general population aim to contribute to knowledge on the risk from radon, particularly by evaluating temporal factors and interaction of radon exposure and smoking

  14. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  15. Effects of radon in indoor air studied

    International Nuclear Information System (INIS)

    Auvinen, A.

    1994-01-01

    Radon is an odorless, tasteless and colourless radioactive noble gas that enters indoor air from the ground. Radon causes lung cancer. A committee set up to evaluate the health risks of chemical substances has been drafting a report on radon, which will compile the major research findings on the lung cancer risk posed by radon. Animal tests have shown that even small doses of radon can cause lung cancer. Smokers seem to contract radon-induced lung cancer more readily than non-smokers. Because research findings have been conflicting, however, it is not known exactly how high the risk of lung cancer caused by indoor radon exposure really is. Several major research projects are under way to obtain increasingly accurate risk assessments. An on-going European joint project brings together several studies - some already finished, some still being worked on. In this way it will be possible to get more accurate risk assessments than from individual studies. In order to prevent lung cancer, it is important to continue the work of determining and reducing radon connects and to combat smoking. (orig.)

  16. How well do radon mitigation strategies work?

    International Nuclear Information System (INIS)

    Matson, N.

    1992-01-01

    Naturally occurring radon in homes can't be completely avoided, but it can be minimized. Indoor air quality researchers compared results of six popular ways to mitigate radon in houses in the Spokane River Valley and New Jersey. Over the course of the past decade, Americans have become aware of the health hazards from radon, a naturally occurring gas that can enter a home through a variety of pathways from the surrounding terrain. Recent research carried out at Lawrence Berkeley Laboratory (LBL) and elsewhere suggests that radon mitigation is feasible but requires long-term monitoring to ensure lasting effectiveness. These studies compare the selection, installation, and performance evaluations of several common radon mitigation strategies

  17. Radon in soils: intercomparative studies

    International Nuclear Information System (INIS)

    Segovia, N.; Galle, C.; Seidel, J.-L.; Monnin, M.

    1988-01-01

    Two kinds of experiments were designed to evaluate some of the variations that can be expected from radon in soil concentrations as monitored by closely spaced solid state nuclear track detectors (SSNTDs). Measurements were performed by the Insituto Nacional de Investigations Nucleares in Mexico and the Laboratoire de Physique Corpusculaire in France. The first experimental design consisted of a series of 15 day exposures of twenty monitoring devices placed inside a single bore hole. Fluctuations obtained in the radon levels at the twenty closely spaced monitoring sites ranged from 9% to 33%. The second experiment was performed with 4 pairs of radon monitoring devices located at 4 different sites at the summit of the Nevado de Toluca volcano. Results show that the SSNTD technique is well suited for radon measurements intended for geophysical studies. (author)

  18. Radon in soils: intercomparative studies

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Galle, C. (Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico)); Seidel, J.-L.; Monnin, M. (Clermont-Ferrand-2 Univ., 63 - Aubiere (France). Lab. de Physique Corpusculaire)

    1988-01-01

    Two kinds of experiments were designed to evaluate some of the variations that can be expected from radon in soil concentrations as monitored by closely spaced solid state nuclear track detectors (SSNTDs). Measurements were performed by the Insituto Nacional de Investigations Nucleares in Mexico and the Laboratoire de Physique Corpusculaire in France. The first experimental design consisted of a series of 15 day exposures of twenty monitoring devices placed inside a single bore hole. Fluctuations obtained in the radon levels at the twenty closely spaced monitoring sites ranged from 9% to 33%. The second experiment was performed with 4 pairs of radon monitoring devices located at 4 different sites at the summit of the Nevado de Toluca volcano. Results show that the SSNTD technique is well suited for radon measurements intended for geophysical studies. (author).

  19. Evaluation of radon-222 concentrations levels at workplaces of Curitiba, PR, Brazil

    International Nuclear Information System (INIS)

    Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Perna, Allan F.N.; Reque, Marilson; Martins Neto, Manoel R.; Denyak, Valeriy

    2013-01-01

    The radon is noble radioactive gas, which when inhaled and undergoing spontaneous decay emits alpha particles that interacting with the cells of biological tissue stimulates the development of lung cancer. The isotope 222 Rn is responsible for approximately half of the effective dose received by the population from natural radiation sources. Current work is focused at the evaluation of the radon concentration levels in air of different workplaces at Curitiba-PR. For this purpose 126 track-etched detectors CR-39 were mounted inside the diffusion chambers that were distributed at workplaces of three enterprises environments for a period of three months approximately. The diffusion chambers were protected by a borosilicate glass fiber filters. After the exposition in air the detectors were submitted to chemical etching using a solution of 6.25M NaOH at 70°C during 14 hours. Such chemical treatment enables to count alpha particle track using an optical microscope with 100x objective magnification. The density of alpha particle tracks in CR-39 was converted to the radon activity concentration in air using the results of previous calibration performed at the National Institute of Radiological Sciences (NIRS) in Japan. Obtained results show that the concentration of 222 Rn in air at studied workplaces varied from 16±2 Bq/m³ to 78±9 Bq/m³. These values are considered within the limits established by international regulatory agencies such as EPA and ICRP, which consider as normal the radon activity up to 200 Bq/m³ and 148 Bq/m³, respectively. (author)

  20. Evaluation of radon-222 concentrations levels at workplaces of Curitiba, PR, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Perna, Allan F.N.; Reque, Marilson; Martins Neto, Manoel R., E-mail: flavia_delclaro@yahoo.com.br, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba - PR (Brazil); Denyak, Valeriy, E-mail: denyak@gmail.com [Instituto de Pesquisa Pele Pequeno Principe (FPP), Curitiba - PR (Brazil)

    2013-07-01

    The radon is noble radioactive gas, which when inhaled and undergoing spontaneous decay emits alpha particles that interacting with the cells of biological tissue stimulates the development of lung cancer. The isotope {sup 222}Rn is responsible for approximately half of the effective dose received by the population from natural radiation sources. Current work is focused at the evaluation of the radon concentration levels in air of different workplaces at Curitiba-PR. For this purpose 126 track-etched detectors CR-39 were mounted inside the diffusion chambers that were distributed at workplaces of three enterprises environments for a period of three months approximately. The diffusion chambers were protected by a borosilicate glass fiber filters. After the exposition in air the detectors were submitted to chemical etching using a solution of 6.25M NaOH at 70°C during 14 hours. Such chemical treatment enables to count alpha particle track using an optical microscope with 100x objective magnification. The density of alpha particle tracks in CR-39 was converted to the radon activity concentration in air using the results of previous calibration performed at the National Institute of Radiological Sciences (NIRS) in Japan. Obtained results show that the concentration of {sup 222}Rn in air at studied workplaces varied from 16±2 Bq/m³ to 78±9 Bq/m³. These values are considered within the limits established by international regulatory agencies such as EPA and ICRP, which consider as normal the radon activity up to 200 Bq/m³ and 148 Bq/m³, respectively. (author)

  1. Radon in homes of the Portland, Oregon Area: Radon data from local radon testing companies collected by CRM (Continuous Radon Measurement) machines

    Science.gov (United States)

    Whitney, H.; Lindsey, K.; Linde, T.; Burns, S. F.

    2013-12-01

    Students from the Department of Geology at Portland State University paired up with the Oregon Health Authority to better understand radon gas values in homes of the Portland metropolitan area. This study focuses on radon values collected by continuous radon measurement (CRM) machines, taken by local radon testing companies. The local companies participating in this study include Alpha Environmental Services, Inc., Cascade Radon, Environmental Works, The House Detectives, LLC, and Soil Solutions Environmental Services, Inc. In total, 2491 radon readings spanning across 77 zip codes were collected from local companies in the Portland metropolitan area. The maximum value, average value, percentage of homes greater than 4 pCi/L and total rank sum was calculated and used to determine the overall radon potential for each zip code (Burns et al., 1998). A list and four maps were produced showing the results from each category. Out of the total records, 24 zip codes resulted in high radon potential and the average reading for the entire Portland Metropolitan area was 3.7 pCi/L. High potential zip codes are thought to be a result of sand and gravel (Missoula Flood deposits) and faults present in the subsurface. The CRM data was compared with both long-term and short-term data provided by the Oregon Health Authority to validate radon potentials in each zip code. If a home is located in a zip code with high or moderate radon potential across two types of data sets, it is recommended that those homes be tested for radon gas.

  2. Research on groundwater radon as a fluid phase precursor to earthquakes

    International Nuclear Information System (INIS)

    Teng, T.; Sun, L.

    1986-01-01

    Groundwater radon monitoring work carried out in southern California by the University of Southern California since 1974 is summarized here. This effort began with a sampling network over a locked segment of the San Andreas fault from Tejon to Cajon and was later expanded to cover part of the southern Transverse Mountain ranges. Groundwater samples were brought back weekly to the laboratory for high precision scintillation counting. Needs for more frequent sampling and less labor prompted the development of an economical and field worthy instrument known as the continuous radon monitor. About 10 have been installed in the network since early 1980. The groundwater radon content was found to show anomalous increases (mostly at a single station) before a number of moderate and nearby earthquakes. Our work is hampered by a lack of large earthquakes that may have a regional impact on radon anomalies and by the complexity of the underground hydrological regime. To circumvent this difficulty, we have chosen to monitor only deep artesian wells or hot spring wells

  3. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  4. Radon flux maps for the Netherlands and Europe using terrestrial gamma radiation derived from soil radionuclides

    Science.gov (United States)

    Manohar, S. N.; Meijer, H. A. J.; Herber, M. A.

    2013-12-01

    Naturally occurring radioactive noble gas, radon (222Rn) is a valuable tracer to study atmospheric processes and to validate global chemical transport models. However, the use of radon as a proxy in atmospheric and climate research is limited by the uncertainties in the magnitude and distribution of the radon flux density over the Earth's surface. Terrestrial gamma radiation is a useful proxy for generating radon flux maps. A previously reported radon flux map of Europe used terrestrial gamma radiation extracted from automated radiation monitoring networks. This approach failed to account for the influence of local artificial radiation sources around the detector, leading to under/over estimation of the reported radon flux values at different locations. We present an alternative approach based on soil radionuclides which enables us to generate accurate radon flux maps with good confidence. Firstly, we present a detailed comparison between the terrestrial gamma radiation obtained from the National Radiation Monitoring network of the Netherlands and the terrestrial gamma radiation calculated from soil radionuclides. Extending further, we generated radon flux maps of the Netherlands and Europe using our proposed approach. The modelled flux values for the Netherlands agree reasonably well with the two observed direct radon flux measurements (within 2σ level). On the European scale, we find that the observed radon flux values are higher than our modelled values and we introduce a correction factor to account for this difference. Our approach discussed in this paper enables us to develop reliable and accurate radon flux maps in countries with little or no information on radon flux values.

  5. Radon analyser

    International Nuclear Information System (INIS)

    1981-01-01

    The process claimed includes the steps of transferring radon gas produced by a sample to a charcoal trap, cooled to a temperature whereby the radon is absorbed by the charcoal, heating the charcoal trap to a sufficient temperature to release the radon, and transferring the radon to a counting device where the gas particles are counted

  6. Evaluation of annual effective dose from indoor radon concentration in Eastern Province, Dammam, Saudi Arabia

    Science.gov (United States)

    Abuelhia, E.

    2017-11-01

    The aim of this study is to determine the indoor radon concentration and to evaluate the annual effective dose received by the inhabitants in Dammam, Al-Khobar, and compare it with new premises built at university of dammam. The research has been carried out by using active detection method; Electronic Radon Detector (RAD-7) a solid state α-detector with its special accessories. The indoor radon concentration measured varies from 10.2 Bqm-3 to 25.8 Bqm-3 with an average value of 18.8 Bqm-3 and 19.7 Bqm-3 to 23.5 Bqm-3 with an average value of 21.7 Bqm-3, in Dammam and Al-khobar dwellings, respectively. In university of dammam the radon concentration varies from 7.4 Bqm-3 to 15.8 Bqm-3 with an average value of 9.02 Bqm-3. The values of annual effective doses were found to be 0.47mSv/y, 0.55mSv/y, and 0.23mSv/y, in Dammam, Al-khobar and university new premises, respectively. The average radon concentration in the old dwellings was two times compared to that in the new premises and it was 25.4 Bqm-3 lower than the world average value of 40 Bqm-3 reported by the UNSCEAR. The annual effective doses in the old dwellings was found to be (0.55mSv/y) two times the doses received at the new premises, and below the world wide average of 1.15mSv/y reported by ICRP (2010). The indoor radon concentration in the study region is safe as far as health hazard is concerned.

  7. Radon measurements along active faults in the Langadas Basin, northern Greece

    Directory of Open Access Journals (Sweden)

    C. Papastefanou

    2001-01-01

    Full Text Available A network of three radon stations has been established in the Langadas Basin, northern Greece for radon monitoring by various techniques in earthquake prediction studies. Specially made devices with plastic tubes including Alpha Tracketch Detectors (ATD were installed for registering alpha particles from radon and radon decay products exhaled from the ground, every 2 weeks, by using LR-115, type II, non-strippable Kodak films, starting from December 1996. Simultaneous measurements started using Lucas cells alpha spectrometer for instantaneous radon measurements in soil gas, before and after setting ATDs at the radon stations. Continuous monitoring of radon gas exhaling from the ground started from the middle of August 1999 by using silicon diode detectors, which simultaneously register meteorological parameters, such as rainfall, temperature and barometric pressure. The obtained data were studied together with the data of seismic events, such as the magnitude, ML, of earthquakes that occurred at the Langadas Basin during the period of measurements, as registered by the Laboratory of Geophysics, Aristotle University of Thessaloniki, in order to find out any association between them.

  8. Design and evaluation of representative indoor radon surveys

    International Nuclear Information System (INIS)

    Csige, I.; Csegzi, S.

    2004-01-01

    We have developed a procedure to design and evaluate representative indoor radon surveys. The procedure is based on random sampling of a population of houses and careful statistical analysis of measured indoor radon concentrations. The method is designed to estimate the fraction of houses in which annual average 222 Rn activity concentration may exceed a certain reference level. Measurements of annual average indoor 222 Rn activity concentration were done in sleeping rooms at pillow level using etched track type radon detectors. We applied the above procedure in an old fashioned village and in a fast developing small city in Transylvania, Romania. In the village almost all houses were single floor wooden made houses without cellar built with traditional technology on a geologically uniform area. The distribution of indoor 222 Rn activity concentration in a sample of 115 houses can almost perfectly be fitted with log-normal probability density function. The correlation coefficient of linear fitting on linearized scales was k = -0.9980. The percentages of houses expected to have annual average 222 Rn activity concentration higher than 400 Bq m -3 is less than 1 %, and of those higher than 600 Bq m -3 can be estimated to be around 0.1 %. The small city, on the other hand lies on a geologically inhomogeneous area, and house construction technology has also changed dramatically in past decades. The resulting distribution of measured indoor 222 Rn activity concentration in a sample of 116 houses cannot be fitted with any simple probability density function. Therefore the prediction of the fraction of houses in which the annual average 222 Rn activity concentration may exceed a certain reference level could not be done adequately. With certain assumptions we estimated that the percentages of houses expected to have annual average 222 Rn activity concentration higher than 400 Bq m -3 is between 3 and 7 %, and of those higher than 600 Bq m -3 can be estimated to be between

  9. Outdoor radon variation in Romania

    International Nuclear Information System (INIS)

    Simion, Elena; Simion, Florin

    2008-01-01

    Full text: The results of a long-term survey (1992 - 2006) of the variations of outdoor radon concentrations in semi-natural location from Romania are reported in the present paper. Measurements, covering between two and four sessions of the day (morning, afternoon, evening and night), were performed on a daily bases by 37 Environmental Radioactivity Monitoring Stations from National Environmental Radioactivity Survey Network. The method used was based on indirect determination of outdoor radon from aerosol samples collected on glass micro-fibre filters by drawing the air through the filters. The sampling was performed in a fixed place at a height of 2 m above the ground surface. Total beta counting of aerosol samples collected was performed immediately and after 20 hours. Values recorded during the years of continuous measurement indicated the presence of several patterns in the long-term variation of outdoor radon concentration: diurnal, seasonal and annual variation. For diurnal variation, outdoor radon concentration shows a maximum values in the night (early hours) and minimum values by day (in the afternoon). On average, this maximum is a factor of 2 higher than the minimum. Late autumn - beginning of winter maximum and an early spring minimum are characteristic for seasonal patterns. In the long term a seasonal pattern was observed for diurnal variation, with an average diurnal maximum to minimum ratio of 1.33 in winter compared with 3.0 in the summer months. The variations of outdoor radon levels showed little correlation with the uranium concentration of the ground and were attributed to changes in soil moisture content. In dry seasons, because of the low precipitation, the soil was drying out in the summer allowing fractures to develop and radon to migrate easily through the ground. Depending on micro-climatic and geological conditions, outdoor radon average concentrations in different regions of Romania are from 1200 mBq/mc to 13065 mBq/mc. The smallest

  10. Rapid determination of radon daughter concentrations

    International Nuclear Information System (INIS)

    Bigu, J.

    1990-08-01

    A technical evaluation of four radon 222 progeny measuring instruments has been conducted. The evaluation has been carried out under laboratory controlled conditions and at several locations in an underground uranium mine. The laboratory evaluation consisted of a thorough study of the behaviour and performance of the instruments under a wide variety of environmental conditions such as radon 222 gas concentration, radon 222 progeny concentration, temperature, relative humidity, aerosol concentration, and gamma-field exposure. The four instruments tested were: the Pylon WL-1000C, the MDA IWLM-811, the MIMIL IIM, and the EDA WLM-30. The readings of the instruments were compared with a widely accepted radon 222 progeny concentration measuring method, namely, the Thomas-Tsivoglou method. Two variables affected two instruments significantly, namely, under high aerosol concentration conditions, one of the instruments (EDA WLM-30) ceased to operate because of filter loading. The other variable was gamma-field exposure which affected another instrument (MDA-811) adversely. The instruments were rated according to several criteria. The overall best performer was the MIMIL IIM, although other instruments also fared quite well under a variety of experimental conditions

  11. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  12. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  13. Solar eruptions - soil radon - earthquakes

    International Nuclear Information System (INIS)

    Saghatelyan, E.; Petrosyan, L.; Aghbalyan, Yu.; Baburyan, M.; Araratyan, L.

    2004-01-01

    For the first time a new natural phenomenon was established: a contrasting increase in the soil radon level under the influence of solar flares. Such an increase is one of geochemical indicators of earthquakes. Most researchers consider this a phenomenon of exclusively terrestrial processes. Investigations regarding the link of earthquakes to solar activity carried out during the last decade in different countries are based on the analysis of statistical data ΣΕ (t) and W (t). As established, the overall seismicity of the Earth and its separate regions depends of an 11-year long cycle of solar activity. Data provided in the paper based on experimental studies serve the first step on the way of experimental data on revealing cause-and-reason solar-terrestrials bonds in a series s olar eruption-lithosphere radon-earthquakes . They need further collection of experimental data. For the first time, through radon constituent of terrestrial radiation objectification has been made of elementary lattice of the Hartmann's network contoured out by bio location method. As found out, radon concentration variations in Hartmann's network nodes determine the dynamics of solar-terrestrial relationships. Of the three types of rapidly running processes conditioned by solar-terrestrial bonds earthquakes are attributed to rapidly running destructive processes that occur in the most intense way at the juncture of tectonic massifs, along transformed and deep failures. The basic factors provoking the earthquakes are both magnetic-structural effects and a long-term (over 5 months) bombing of the surface of lithosphere by highly energetic particles of corpuscular solar flows, this being approved by photometry. As a result of solar flares that occurred from 29 October to 4 November 2003, a sharply contrasting increase in soil radon was established which is an earthquake indicator on the territory of Yerevan City. A month and a half later, earthquakes occurred in San-Francisco, Iran, Turkey

  14. Measurements of radon levels inside Mexican caves

    International Nuclear Information System (INIS)

    Borau, J.; Gonzalez, A.; Espinosa, G.; Golzarri, J.I.

    1993-01-01

    Living animal species on earth have been exposed to environmental radon from the very beginning of time. The effects of radiation, combined with other natural parameters such as temperature, humidity, salt contents, etc., have most likely influenced the evaluation of different species. Thus, it is important to know and to evaluate the radon levels, among other radioactive elements present in enclosed environments such as caves, especially since those caves were also the dwellings and refuge of the predecessor of man. In this work we present radon level measurements inside some caves with vestiges of ancient inhabitats and some recently discovered natural caves, using Nuclear Track Detectors. (author)

  15. Radon exposure of passengers in the Prague metro

    International Nuclear Information System (INIS)

    Sabol, J.

    1996-01-01

    This paper summarises the results of radon concentration monitoring in the carriages and at some stations of the Prague Metro network. The measurements revealed that radon levels in the Metro are relatively low in comparison to those normally encountered in dwellings in the Prague region. On average, the radon concentrations in the air inside the carriages have been found to be about 11 - 12 Bq m -3 while the levels at most stations reached values between 10 and 15 Bq m -3 . The Metro is intensively ventilated by means of powerful blowers and fans; the piston effect of the moving trains also contributes to air exchange. The ventilation rate is typically 3-4 h -1 . The highest rate is in line C, where the air in all underground areas is completely exchanged 6 times within each hour. These results demonstrate that Metro passengers receive about the same effective dose as passengers using surface transport. The doses from radon in the metro are only slightly higher than radon-related doses in the open air, while exposure due to external photon radiation seems to be a few percent lower than dose rates common in typical Czech houses. (author)

  16. Evaluating for a geospatial relationship between radon levels and thyroid cancer in Pennsylvania.

    Science.gov (United States)

    Goyal, Neerav; Camacho, Fabian; Mangano, Joseph; Goldenberg, David

    2015-01-01

    To determine whether there is an association between radon levels and the rise in incidence of thyroid cancer in Pennsylvania. Epidemiological study of the state of Pennsylvania. We used information from the Pennsylvania Cancer Registry and the Pennsylvania Department of Energy. From the registry, information regarding thyroid incidence by county and zip code was recorded. Information regarding radon levels per county was recorded from the state. Poisson regression models were fit predicting county-level thyroid incidence and change as a function of radon/lagged radon levels. To account for measurement error in the radon levels, a Bayesian Model extending the Poisson models was fit. Geospatial clustering analysis was also performed. No association was noted between cumulative radon levels and thyroid incidence. In the Poisson modeling, no significant association was noted between county radon level and thyroid cancer incidence (P = .23). Looking for a lag between the radon level and its effect, no significant effect was seen with a lag of 0 to 6 years between exposure and effect (P = .063 to P = .59). The Bayesian models also failed to show a statistically significant association. A cluster of high thyroid cancer incidence was found in western Pennsylvania. Through a variety of models, no association was elicited between annual radon levels recorded in Pennsylvania and the rising incidence of thyroid cancer. However, a cluster of thyroid cancer incidence was found in western Pennsylvania. Further studies may be helpful in looking for other exposures or associations. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  18. A technical evaluation of the EDA radon gas continuous monitoring system

    International Nuclear Information System (INIS)

    Bigu, J.

    1979-04-01

    Extensive laboratory and underground tests were conducted with a radon gas continuous monitoring system built by EDA Instruments Inc. The system consists of several remote radon gas sensors linked via signal cables to a central control unit that fully controls the operation of the radon monitors. The system enables four operations to be performed: sampling, background, flush and bypass. The sequence and duration of these functions is programmable. Up to 20 functions in any desired pattern each lasting from 1 min to 23 hr 59 min can be programmed. Several programs were used during the experiments in order to obtain radon and thoron gas levels. The performance of the EDA system was quite satisfactory. It is suggested that ruggedization as well as some other modifications be introdouced into the system to: a) better withstand the harsh underground environment; and b) improve its performance

  19. Analysis of digital fluxgate magnetometer and radon data of MPGO network in Kachchh

    International Nuclear Information System (INIS)

    Prasad, M.S.B.S.; Gupta, Arun; Pradhan, Rashmi; Rastogi, B.K.; Rawat, Gautam

    2010-01-01

    Institute of Seismological Research (ISR) has established a network of four Multi-parametric Geophysical Observatories (MPGO) at Bhachau, Vamka, Desalpar and Badargadh in Kachchh which fall in the aftershock zone of 2001 Bhuj earthquake (Mw 7.7) for earthquake prediction research. Two Magson digital fluxgate magnetometers (DFM) have been installed on February 07, 2009 to observe magnetic precursors, if any, at Desalpar and Vamka in Kachchh. The daily variations of geomagnetic horizontal and vertical components are being continuously observed at a sampling interval of 1 Hz. Variations of about 2-9 nT in vertical component have been observed during earthquakes of Mw = 4 occurring within a radius of 65 km from Vamka and 80 km from Desalpar. Conventional polarization analysis of DFM data is implemented to check lithospheric origin of electromagnetic signals. Geomagnetic transfer function is calculated to observe any subsurface conductivity variation beneath the measuring sites. Further a strong radon anomaly at Vamka and Chobari sites has been observed 7 days before Mw 4.1 earthquake of 12 April 2009 which is at a distance of 29 km W from Vamka and 23 Km SW from Chobari. DFM and Radon sensors were installed as a part of MPGO instruments and these data will be supplemented by several other parameters. Preliminary results will be presented and discussed in the meetings. (author)

  20. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  1. Airflow measurement techniques applied to radon mitigation problems

    International Nuclear Information System (INIS)

    Harrje, D.T.; Gadsby, K.J.

    1989-01-01

    During the past decade a multitude of diagnostic procedures associated with the evaluation of air infiltration and air leakage sites have been developed. The spirit of international cooperation and exchange of ideas within the AIC-AIVC conferences has greatly facilitated the adoption and use of these measurement techniques in the countries participating in Annex V. But wide application of such diagnostic methods are not limited to air infiltration alone. The subject of this paper concerns the ways to evaluate and improve radon reduction in buildings using diagnostic methods directly related to developments familiar to the AIVC. Radon problems are certainly not unique to the United States, and the methods described here have to a degree been applied by researchers of other countries faced with similar problems. The radon problem involves more than a harmful pollutant of the living spaces of our buildings -- it also involves energy to operate radon removal equipment and the loss of interior conditioned air as a direct result. The techniques used for air infiltration evaluation will be shown to be very useful in dealing with the radon mitigation challenge. 10 refs., 7 figs., 1 tab

  2. Radon remediation in irish schools

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    average an approximate 50% reduction in radon concentrations. Active systems require the use of electric fans for their continued successful long-term operation. The performance of a number of fan assisted sub-slab de pressurization systems and fan assisted under floor ventilation systems were evaluated after a minimum of three years operation. It was found that all systems were still operating satisfactorily. It is recommended however that periodic retesting of rooms where active systems are installed should be carried out to ensure the continued successful long-term operation of these systems. (author)

  3. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  4. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  5. Radon and radon daughters in South African underground mines

    International Nuclear Information System (INIS)

    Rolle, R.

    1980-01-01

    Radon and the radon daughters are the radionuclides which primarily determine the level of the radiation hazard in underground uranium mines and to a smaller extent in non-uranium mines. Radon is a gas, and its daughters adsorb on aerosol particles which are of respirable size. The hazard thus arises from the alpha decay of radon and its daughters in contact with lung tissue. Radon is itself part of the uranium decay chain. The major radionuclide, 238 U, decays successively through thirteen shorter-lived radionuclides to 206 Pb. Radon is the only gaseous decay product at room temperature; the other twelve are solids. The main hazard presented by the uranium decay chain is normally determined by the radon concentration because gaseous transport can bring alpha emitters close to sensitive tissue. There is no such transport route for the other alpha emitters, and the level of beta and gamma radiation caused by the uranium decay chain generally presents a far lower external radiation hazard. Radon itself is the heaviest of the noble gases, which are He, Ne, Ar, Kr, Xe and Rn. Its chemical reactions are of no concern in regard to its potential hazard in mines as it may be considered inert. It does, however, have a solubility ten times higher than oxygen in water, and this can play a significant part in assisting the movement of the gas from the rock into airways. Radon continuously emanates into mine workings from uranium ores and from the uranium present at low concentrations in practically any rock. It has been found that the control of the exposure level is most effectively achieved by sound ventilation practices. In South African mines the standard of ventilation is generally high and exposure to radon and radon daughters is at acceptably low levels

  6. Personal radon daughter dosimetry

    International Nuclear Information System (INIS)

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  7. Detection of radon products in atmosphere and its concentration

    International Nuclear Information System (INIS)

    Al-Naemi, H.M.

    1993-01-01

    The climate of the State of Qatar is very warm during the summer and also for considerable parts of the spring and autumn. Energy-tight houses and buildings with air conditioning working day and night for several months are very common. Consequently, the problem of accumulation of indoor radon may exist. No measurements of radon concentration in Qatar have been performed before. The aim of the present work is to implement a suitable technique to measure radon concentration in Qatari houses and buildings. As a first stage, it was found reasonable to start with a technique to evaluate the short-term average indoor radon concentration. The activated charcoal method was chosen to perform this evaluation

  8. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  9. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  10. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  11. Mechanisms of radon injury

    International Nuclear Information System (INIS)

    Cross, F.T.

    1988-01-01

    In this new project, they conduct molecular, cellular and whole-animal research relevant to understanding the inhalation toxicology of radon and radon-daughter exposures. The work specifically addresses the exposure-rate effect in radon-daughter carcinogenesis; the induction-promotion relationships associated with exposure to radon and cigarette-smoke mixtures; the role of oncogenes in radon-induced cancers; the effects of radon on DNA as well as on DNA repair processes; and the involvement of growth factors and their receptors in radon-induced carcinogenesis. Preliminary experiments showed that oncogenes are activated in radon-induced lung tumors. They have therefore begun further exposures pertinent to the oncogene and growth-factor studies. An in vitro radon cellular-exposure system was designed, and cell exposures were initiated. Initiation-promotion-initiation studies with radon and cigarette-smoke mixtures have also begun; and they are compiling a radon health-effects bibliography

  12. Numerical and analytical assessment of radon diffusion in various media and potential of charcoal as radon detector

    Science.gov (United States)

    Rybalkin, Andrey

    Numerical assessments of radon diffusion together with analytical estimates for short-time and long-time exposure were the first objective of this thesis with the goal to demonstrate how radon propagates in various media. Theoretical predictions were compared to numerical simulations, and obtained values of total radon activities inside each material match quite well with the analytical estimates. These estimates, for activated and nonactivated charcoal, were then used to evaluate the possibility of designing a charcoal system to be used as a radon detector. Another objective was to use nonactivated charcoal samples and measure the level of radon accumulation, and use these data to estimate radon diffusion and adsorption coefficients. The analytical approach was developed to estimate these values. Radon adsorption coefficient in nonactivated charcoal was found to be from 0.2 to 0.4 m3/kg. Radon diffusion coefficient for nonactivated charcoal is in the range of 1.2×10-11 to 5.1×10-10 m2/s in comparison to activated charcoal with adsorption coefficient of 4 m3/kg and diffusion coefficient of 1.43×10-9 m2/s. The third objective was to use GEANT4 numerical code to simulate decay of 238U series and 222Rn in an arbitrary soil sample. Based on that model, the goal was to provide a guideline for merging GEANT4 radioactive decay modeling with the diffusion of radon in a soil sample. It is known that radon can be used as an earthquake predictor by measuring its concentration in groundwater, or if possible, along the faults. Numerical simulations of radon migration by diffusion only were made to estimate how fast and how far radon can move along the fault strands. Among the known cases of successful correlations between radon concentration anomalies and earthquake are the 1966 Tashkent and 1976 Songpan-Pingwu earthquakes. Thus, an idea of radon monitoring along the Wasatch Fault, using system of activated/nonactivated charcoals together with solid state radon detectors is

  13. National Radon Contractor Proficiency (RCP) Program. Proficiency report, June 1991

    International Nuclear Information System (INIS)

    1991-06-01

    The primary objective of the U.S. Environmental Protection Agency's (EPA) efforts to address the indoor radon problem is to reduce radon levels in buildings throughout the country. Achieving the objective requires a nationwide supply of capable radon mitigation contractors. In the Indoor Radon Abatement Act of 1988, Congress authorized EPA to establish a program to evaluate radon mitigation contractors and to provide the information to the public in cooperation with the States. The Radon Contractor Proficiency (RCP) Program was developed to assist States, EPA Regions, local government officials, and the public in selecting contractors who have demonstrated their proficiency in reducing indoor radon levels. The program is managed by the EPA Office of Radiation Programs' Radon Division. Under the voluntary program, radon contractors demonstrate their proficiency by meeting specific Program requirements. Individual contractors who meet these requirements are then listed in periodic RCP Proficiency Reports

  14. National Radon Contractor Proficiency (RCP) program. Proficiency report, September 1991

    International Nuclear Information System (INIS)

    1991-09-01

    The primary objective of the U.S. Environmental Protection Agency's (EPA) efforts to address the indoor radon problem is to reduce radon levels in buildings throughout the country. Achieving this objective requires a nationwide supply of capable radon mitigation contractors. In the Indoor Radon Abatement Act of 1988, Congress authorized EPA to establish a program to evaluate radon mitigation contractors and to provide this information to the public in cooperation with the States. The Radon Contractor Proficiency (RCP) Program was developed to assist States, EPA Regions, local government officials, and the public in selecting contractors who have demonstrated their proficiency in reducing indoor radon levels. The program is managed by the EPA Office of Radiation Programs' Radon Division. Under this voluntary program, radon contractors demonstrate their proficiency by meeting specific Program requirements. Individual contractors who meet these requirements are then listed in the Report

  15. National Radon Contractor Proficiency (RCP) Program. Proficiency report, January 1992

    International Nuclear Information System (INIS)

    1992-01-01

    The primary objective of the U.S. Environmental Protection Agency's (EPA) efforts to address the indoor radon problem is to reduce radon levels in buildings throughout the country. Achieving the objective requires a nationwide supply of capable radon mitigation contractors. In the Indoor Radon Abatement Act of 1988, Congress authorized EPA to establish a program to evaluate radon mitigation contractors and to provide the information to the public in cooperation with the States. The Radon Contractor Proficiency (RCP) Program was developed to assist States, EPA Regions, local government officials, and the public in selecting contractors who have demonstrated their proficiency in reducing indoor radon levels. The program is managed by the EPA Office of Radiation Programs' Radon Division. Under the voluntary program, radon contractors demonstrate their proficiency by meeting specific Program requirements. Individual contractors who meet these requirements are then listed in the Report

  16. Radon-hazard potential the Beaver basin, Utah

    International Nuclear Information System (INIS)

    Bishop, C.E.

    1995-01-01

    Indoor-radon levels in the Beaver basin of southwestern Utah are the highest recorded to date in Utah, ranging from 17.5 to 495 picocuries per liter (pCi/L). Because the U.S. Environment Protection Agency considers indoor-radon levels above 4 pCi/L to represent a risk of lung cancer from long-term exposure, the Utah Geological Survey is preparing a radon-hazard-potential map for the area to help prioritize indoor testing and evaluate the need for radon-resistant construction. Radon is a chemically inert radioactive gas derived from the decay of uranium-238, which is commonly found in rocks and soils. Soil permeability, depth to ground water, and uranium/thorium content of source materials control the mobility and concentration of radon in the soil. Once formed, radon diffuses into the pore space of the soil and then to the atmosphere or into buildings by pressure-driven flow of air or additional diffusion. The Beaver basin has been a topographic and structural depression since late Miocene time. Paleocene to Miocene volcanic and igneous rocks border the basin. Uraniferous alluvial-fan, piedmont-slope, flood-plain, and lacustrine sediments derived from the surrounding volcanic rocks fill the basin. A soil-gas radon and ground radioactivity survey in the Beaver basin shows that soils have high levels of radon gas. In this survey, uranium concentrations range from 3 to 13 parts per million (ppm) and thorium concentrations range from 10 to 48 ppm. Radon concentrations in the soil gas ranged from 85 to 3,500 pCi/L. The highest concentrations of uranium, thorium, and radon gas and the highest radon-hazard-potential are in the well-drained permeable soils in the lower flood- plain deposits that underlie the city of Beaver

  17. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  18. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  19. Compact detector for radon and radon daughter products

    International Nuclear Information System (INIS)

    Alter, H.W.; Oswald, R.A.

    1986-01-01

    This invention provides an improved compact track registration detector for radon gas. The detector comprises a housing having an open mouth, a bottom, and side walls; track registration means, supported inside the housing, which forms damage tracks along paths traversed by alpha particles; a microporous filter positioned across the mouth of the housing to prevent entry of radon daughters and particulate matter; and a cap that may be placed on the mouth of the housing to retain the filter. The housing has internal wall surfaces dimensioned to optimize the registration of alpha particles from radon and radon daughters present in the housing

  20. The use of soil gas as radon source in radon chambers

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2009-01-01

    A procedure is described in which soil gas is utilized as an alternative to the 226 Ra source for the supply of the radon gas required to fill a radon chamber where radon-measuring devices are calibrated. The procedure offers opportunities to vary the radon concentration within the chamber around an average value of about 500 Bq/m 3 , which is considered to be sufficient for calibrating indoor radon detectors. The procedure is simple and the radon source does not require radiation protection certification (for import and/or use), unlike the commercially produced standard radioactive ( 226 Ra) sources.

  1. Radon in Antarctica

    International Nuclear Information System (INIS)

    Ilic, R.; Rusov, V.D.; Pavlovych, V.N.; Vaschenko, V.M.; Hanzic, L.; Bondarchuk, Y.A.

    2005-01-01

    The paper reviews results of radon measurements obtained in Antarctic research stations in the last 40 years by both active and passive radon monitors. A brief description of the radon laboratory set-up in the Ukrainian Academician Vernadsky station on the Antarctic Peninsula (W 64 o 16 ' , S 65 o 15 ' ), where radon is measured by two types of etched track Rn dosimeter and 4 types of continuous radon monitoring devices is presented. Some selected results of research work are described related to: (i) analysis of radon storms, defined as an abrupt increase of 222 Rn during the occurrence of a cyclone, and its applicability for the study of the transport of air masses of continental origin to Antarctica; (ii) a study of the correlation of changes of radon concentration and geomagnetic field induced by tectonic activity and its application to predicting tectonomagnetic anomalies, and (iii) verification of a newly developed theoretical model based on noise analysis of the measured radon signal for earthquake prediction. Suggestions for future utilization of radon for basic research in Antarctica (and not only in Antarctica) conclude the contribution. conclude the contribution

  2. Temperature calibration formula for activated charcoal radon collectors

    International Nuclear Information System (INIS)

    Cooper, Alexandre; Le, Thiem Ngoc; Iimoto, Takeshi; Kosako, Toshiso

    2011-01-01

    Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m 3 radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces. - Research highlights: → The temperature effect on radon adsorption is proportional to αe β/T . → The calibration formula is CF(T,t)=3.1x10 -5 e (2887)/((T+273)) [1-e -0.080t ]. → The radon adsorption efficiency varies up to a factor of two for T = 8.5-31 o C. → The average temperature is suitable for estimating CF(T,t) in a fluctuating environment.

  3. Temperature calibration formula for activated charcoal radon collectors

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Alexandre, E-mail: alexandre.cooper@gmail.co [Graduate School of Engineering, University of Tokyo, 2-11-16 Yayoi, Bunkyo-ku, Tokyo 113-0032 (Japan); Le, Thiem Ngoc [Institute of Nuclear Science and Technology, Vietnam Atomic Energy Commission, 59 Ly Thuong Kiet, Hanoi (Viet Nam); Iimoto, Takeshi; Kosako, Toshiso [Graduate School of Engineering, University of Tokyo, 2-11-16 Yayoi, Bunkyo-ku, Tokyo 113-0032 (Japan)

    2011-01-15

    Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m{sup 3} radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces. - Research highlights: {yields} The temperature effect on radon adsorption is proportional to {alpha}e{sup {beta}/T}. {yields} The calibration formula is CF(T,t)=3.1x10{sup -5}e{sup (2887)/((T+273))} [1-e{sup -0.080t}]. {yields} The radon adsorption efficiency varies up to a factor of two for T = 8.5-31 {sup o}C. {yields} The average temperature is suitable for estimating CF(T,t) in a fluctuating environment.

  4. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  5. Formulation of the fundamental basis for the evaluation of the comparability of different measuring method for the determination of ground air radon concentration. Vol. 2. Report on ground air radon measurements - influence factors, measuring methods, evaluation; Erarbeitung fachlicher Grundlagen zur Beurteilung der Vergleichbarkeit unterschiedlicher Messmethoden zur Bestimmung der Radonbodenluftkonzentration. Bd. 2. Sachstandsbericht ''Radonmessungen in der Bodenluft - Einflussfaktoren, Messverfahren, Bewertung''

    Energy Technology Data Exchange (ETDEWEB)

    Kemski, J.; Klingel, R.; Siehl, A.; Neznal, M.; Matolin, M.

    2012-03-15

    The report on ground air radon measurements covers the following issues: Introduction; Radon in the geogenic underground: emanation, migration, exhalation; Influencing factors: geochemical parameters, structural situation, geomorphology, exogenic effects; Ground air measurements: site exploration, tectonics, earth quake prognosis, radon in ground air and buildings; Radon measurement: sampling and measuring methods, error consideration, comparative measurements, practical examples; measuring regulations and recommendations; Variability of the radon concentration: temporal variation, sampling depth, spatial variations; Evaluation and conclusions.

  6. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  7. Time Series Analysis of Soil Radon Data Using Multiple Linear Regression and Artificial Neural Network in Seismic Precursory Studies

    Science.gov (United States)

    Singh, S.; Jaishi, H. P.; Tiwari, R. P.; Tiwari, R. C.

    2017-07-01

    This paper reports the analysis of soil radon data recorded in the seismic zone-V, located in the northeastern part of India (latitude 23.73N, longitude 92.73E). Continuous measurements of soil-gas emission along Chite fault in Mizoram (India) were carried out with the replacement of solid-state nuclear track detectors at weekly interval. The present study was done for the period from March 2013 to May 2015 using LR-115 Type II detectors, manufactured by Kodak Pathe, France. In order to reduce the influence of meteorological parameters, statistical analysis tools such as multiple linear regression and artificial neural network have been used. Decrease in radon concentration was recorded prior to some earthquakes that occurred during the observation period. Some false anomalies were also recorded which may be attributed to the ongoing crustal deformation which was not major enough to produce an earthquake.

  8. Cornerstones of the Austrian radon risk communication strategy

    International Nuclear Information System (INIS)

    Kunte, A.; Ringer, W.

    2015-01-01

    On behalf of the Federal Ministry of Agriculture, Forestry, Environment and Water Management (BMLFUW), the National Radon Centre of Austria developed the National Radon Risk Communication Strategy. The superior goal is the reduction of the radon exposure of Austrian citizens as well as the reduction of radon-related lung cancer deaths. Austria, like many other countries, follows the approach to raise awareness and to inform the public to achieve this goal. The presented strategy deals with the question of how radon protection issues can be communicated to the public, existing fears can be reduced and affected people can be motivated to take action (perform a radon test, if necessary, mitigate or install preventive measures in new buildings). The cornerstones of the National Radon Risk Communication Strategy can be summarized as follows: - Definition of communication goals - Identification and categorization of target groups - Development of specific key messages for each of the target groups - Determination of communication channels and assessment of their efficiency - Integration of the radon issue in education and training - Cooperation with relevant organizations and platforms. The communication objectives, target groups and communication paths (and their evaluation) will be discussed during the presentation in detail.

  9. Radon as a groundwater tracer in Forsmark and Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Grolander, Sara

    2009-10-15

    caused by the homogenous radon concentrations measured in the Laxemar area. The radon concentrations in near surface water measured in Forsmark showed large variability with both low and high radon concentrations. This large variability in radon concentration could not be explained by the flow pattern of the groundwater since no clear correlation between radon concentration and recharge/discharge classification was found. The radon concentration was also measured at different depths in the soil profile at three locations in the Forsmark area. The results showed large differences with increasing radon concentration with increasing depth. This gradient of radon concentration can be explained largely by the radon emanation potential of the local soil type at different depths. High radon concentrations were found in wells with higher radon emanation potential like till and bedrock. These observations showed the importance of the radon emanation potential of the local soil for the radon concentration in groundwater. The main purpose of this study has been to evaluate the use of radon as a tracer for groundwater flow patterns. The method is based on the ingrowth of radon from its progenitor radium according to the law of radioactive decay. According to this law the radon concentration in groundwater will reach equilibrium conditions after approximately 30 days in contact with the surrounding soil. The equilibrium radon concentration of the near surface groundwater was measured at several location in the Forsmark area and a range of the steady state radon concentration was calculated. The measured steady state radon concentration was then used to evaluate the radon concentrations measured in near surface groundwater in the area. A recharge/discharge classification of the wells was done based on the range of steady state radon concentration and the measured radon concentrations in groundwater. All wells with radon concentration below the steady state radon concentration were

  10. Radon diffusion coefficients for soils. Previous studies and their application to uranium-bearing wastes

    International Nuclear Information System (INIS)

    Sasaki, Tomozo; Gunji, Yasuyoshi; Iida, Takao

    2008-01-01

    Radon diffusion in soils has been studied over the years by many researchers. The application of such studies to the evaluation of radiation exposure caused by radon from uranium-bearing wastes disposed in a shallow land site is very important. The present paper surveyed closely relevant studies and elucidated the inherent nature of radon diffusion in terms of the definition of radon diffusion coefficients. Then, basic features of measurement methods for determining radon diffusion coefficients in soils were explained. Furthermore, theoretical aspects of radon diffusion in soils were discussed in terms of microscopic radon diffusion in soils and large-scale radon diffusion through cover soil defects for uranium mill tailings. Finally, in order to apply the radon diffusion studies to uranium-bearing waste disposal in shallow land sites, new challenges were presented: elucidation of radon diffusion in uranium-bearing wastes and cover-soil cracks, and demonstration of the validity of applying only radon diffusion in the evaluation of radiation exposure caused by radon, which would come through Japanese cover soils for uranium-bearing waste disposal. (author)

  11. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  12. Evaluation of radon in hot spring waters in Zacatecas State, Mexico

    International Nuclear Information System (INIS)

    Favila R, E.; Lopez del Rio, H.; Davila R, I.; Mireles G, F.

    2010-10-01

    It is well know that radon is a potent human carcinogen. Because of the health concern of radon exposure, concentrations of 222 Rn were determined in ten hot spring water samples from the Mexican state of Zacatecas. The thermal water is collected in pools and used mainly for recreational purposes. In addition to radon level, the water samples were characterized for temperature, conductivity, and ph. Liquid scintillation spectrometry was used to measure 222 Rn and its decay products by mixing directly an aliquot of water with a commercial liquid scintillation. All measurements were carried out using a liquid scintillation counter (Wallac 1411). The water temperature ranged from 28 to 59 C, while the ph varied from 7.2 to 9.0, and the water conductivity was between 202.4 and 1072 μS/cm. The 222 Rn concentration varied in the range 3.9-32.6 Bq/L. In addition, the risk to radon exposure was assessed by considering three -real and possible- radon exposure scenarios: 1) ingestion of bottled thermal water, 2) direct ingestion of thermal water; and 3) vapor inhalation. The annual effective dose calculated for ingestion of bottled thermal water was 0.010-0.083 mSv/yr; for ingestion of water was 0.65-5.47 mSv/yr; and for inhalation was 0.28-2.81 mSv/yr. (Author)

  13. Evaluation of radon concentration in dwellings and well water of Parana State-Brazil

    International Nuclear Information System (INIS)

    Correa, Janine Nicolosi

    2011-01-01

    Considering the growing interest of International Agencies and national Governmental organs in studies and measurements of radon activity in air, soil gas and ground water (mainly from artesian wells) as well as scarceness of such measurements at Brazilian territory, present studies were initiated by the Laboratory of Applied Nuclear Physics of Federal University of Technology - Parana (UTFPR) in collaboration with the Institute of Radiation Protection and Dosimetry (IRD) and the Center of Nuclear Technology Development (CDTN) of Brazilian Commission on Nuclear Energy (CNEN). This Collaboration started in 2003. Radon monitoring program is based mainly on use of Solid State Nuclear Track Detectors for radon activity measurements in air. Continuous electronic radon detectors are used for radon measurements in soil gas and water. Current work presents the results of indoor 222 Rn activity of dwellings and working places of Curitiba-PR and radon concentration in ground water samples from artesian wells from aquifers of the same area. The indoor measurements of radon activity were performed using Solid State Nuclear Track Detectors CR-39. After the exposition, CR-39 detectors were submitted to chemical development which permitted to make alpha particle tracks counting. The results of calibration of CR-39 together with efficiency of used exhalation chambers as well as alpha particle tracks chemical development procedure were performed in cooperation with CDTN and collaboration with the National Institute of Radiological Sciences (NIRS). The major part of indoor 222 Rn concentration in residences was found below 100 Bq/m3. In the case of working places, all measurements present 222 Rn concentration bellow 100 Bq/m3. The studies of radon activity in water were performed using the samples of water from artesian wells submitted to recursive measurements by instant radon detector AlphaGUARD PQ2000 PRO during few weeks with intervals of about 4 days between each measurement

  14. Mapping of groundwater radon potential

    International Nuclear Information System (INIS)

    Aekerblom, G.; Lindgren, J.

    1997-01-01

    The domestic use of water with elevated radon concentration may represent a public health hazard, partly due to the release of radon to the indoor air. While only a limited number of countries have implemented regulations with respect to radon in water, many more are considering doing so. The compulsory limits proposed by Swedish authorities are 100 Bq/1 for public water, while water from private wells is not to exceed 1000 Bq/1. Furthermore, it is recommended that water with a radon content above 500 Bq/1 should not be given to children under five years of age. In Sweden, the estimated number of wells with radon levels above 1000 Bq/1 exceeds 10,000, with a considerable amount in excess of 10,000 Bq/1. The highest radon concentration in a well supplying drinking water encountered so far is 57,000 Bq/1. Radon levels exceeding 500 Bq/1 are almost exclusively found in wells drilled into bedrock and in springs with intramontaneous water. Elevated ground water radon levels require that the water has passed through bedrock with elevated concentration of uranium, or through fractures with coatings of minerals containing enhanced concentrations of radium-226. Intramontaneous water from areas with uranium-bearing rock types (e.g. uranium-rich granites, pegmatites and vulcanites) often manifests elevated radon levels. Routines for the establishment of risk maps focusing on water are currently under development. The backbone of the process is the access to high spatial resolution radiometric information together with bedrock and soil information on a detailed scale (1:50,000). This information is available from the Geological Survey of Sweden, which is routinely carrying out airborne measurements at an altitude of 30 m and a line spacing of 200 m. While some 60% of Sweden is covered up to now, 75 % is expected to be covered within the next ten years. Other available databases utilized in the risk mapping process include radon measurements in wells, geochemical data from

  15. Geology and occurrence of radon precursors

    International Nuclear Information System (INIS)

    Schmalz, R.F.

    1990-01-01

    The discovery that radioactive radon gas may occur as a significant indoor contaminant in houses and in the workplace has had far-reaching consequences in public health, real estate marketing, the construction industry, health and liability insurance underwriting, and in legislation at the federal and state levels. Many factors are known to affect radon level inside a building - its location, construction, ventilation, and substructure; the climate of the region in which it is located and the life styles of it occupants, for example. Despite the importance of assessing the hazard radon contamination may represent, the economic cost and the time required to screen hundreds of millions of individual buildings make such an effort impracticable. The effectiveness of large-scale regional screening to evaluate radon potential depends on an understanding of the chemical and physical properties of the gas, and of the geological and geochemical factors which control the distribution of its radioactive progenitors, radium, uranium and thorium. It is the purpose of this paper to review and summarize our present knowledge of these large-scale controls on radon occurrence

  16. Biological effects of radon in Drosophila

    International Nuclear Information System (INIS)

    Pimentel P, A.E.; Tavera D, L.; Cruces M, M.P.; Arceo M, C.; Rosa D, M.E. de la

    1992-04-01

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  17. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  18. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  19. Radon programme: presence and future

    International Nuclear Information System (INIS)

    Hulka, J.

    2009-01-01

    In this presentation an overview of radon programme experiences is presented. The paper summarises national radon policy, national programmes, legislation, the role of preventive measures and interventions with respect to existing and future exposure and knowledge of radon risk, problems of remediation strategies, practical protection in dwellings, radon measurements strategies, progress in radon measurement of an individual house (radon diagnosis), radon mapping process and sense of delineation of radon prone areas, natural radioactivity of building materials and radioactivity in public water and their role in the radon programme, public awareness on radon issue and publicity campaign. Some research activities are proposed aiming at effective solutions of radon issues in future

  20. Sampling strategies for indoor radon investigations

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1983-01-01

    Recent investigations prompted by concern about the environmental effects of residential energy conservation have produced many accounts of indoor radon concentrations far above background levels. In many instances time-normalized annual exposures exceeded the 4 WLM per year standard currently used for uranium mining. Further investigations of indoor radon exposures are necessary to judge the extent of the problem and to estimate the practicality of health effects studies. A number of trends can be discerned as more indoor surveys are reported. It is becoming increasingly clear that local geological factors play a major, if not dominant role in determining the distribution of indoor radon concentrations in a given area. Within a giving locale, indoor radon concentrations tend to be log-normally distributed, and sample means differ markedly from one region to another. The appreciation of geological factors and the general log-normality of radon distributions will improve the accuracy of population dose estimates and facilitate the design of preliminary health effects studies. The relative merits of grab samples, short and long term integrated samples, and more complicated dose assessment strategies are discussed in the context of several types of epidemiological investigations. A new passive radon sampler with a 24 hour integration time is described and evaluated as a tool for pilot investigations

  1. Radon

    International Nuclear Information System (INIS)

    1990-01-01

    This leaflet in the At-a-Glance Series, describes what radon is, where it is found, why it presents a risk to health, the official advice, and the remedies that are available to reduce radon levels. (author)

  2. An assessment of the health benefits of radon mitigation of buildings in radon affected areas

    International Nuclear Information System (INIS)

    Denman, A.R.

    1999-06-01

    and unique contribution to the evaluation of the risks of radon and the benefits of remediation programmes, which has been recognised by the acceptance of papers for presentation at two international conferences in 1999. The research provides a framework which permits evaluation of future radon remediation policy and of the value of remediation programmes elsewhere. For example, it may be appropriate to consider remediation of only the schools in a mildly affected area, and only initiate a programme for houses if a high uptake was guaranteed. (author)

  3. Cleaners in reducing the hazards of indoor radon decay products

    International Nuclear Information System (INIS)

    Montassier, N.; Hopke, P.K.; Shi, Y.; Wasiolek, P.; McCallum, B.

    1992-01-01

    The objective of this study was to evaluate the influence of three types of air cleaners on the concentration and size distribution of radon progeny in a normally occupied house. Using an automated, semi-continuous, graded-screen array system and a radon monitor, the activity size distribution and radon concentration was measured and the exposure of the occupants of the home to radon could be assessed. The dose model developed as part of the recently released U.S. National Academy of Sciences report was used to related the exposure to deposited dose in the tissue of the bronchial epithelium. Thus, the effectiveness of the air cleaners in reducing both exposure and dose were evaluated. (author)

  4. Evaluation of radon and radioactivity level in phosphorite area in Guizhou

    International Nuclear Information System (INIS)

    Li Zhou; Yang Zhong; Wei Tao; Zhang Xiaole; Yu Lixin; Tian Zhujuan

    2006-01-01

    Objective: To study and assess atmospheric radon and radioactive levels in one of phosphorite area in Guizhou province. Methods: To monitor and analyze the external irradiation level, atmospheric radon, nuclide levels, and water total radioactivity on the spot and in the laboratory. Results: External irradiation level is 7-18 x 10 -8 Gy/h, the mean value is 12 x 10 -8 Gy/h, atmospheric radon concentration is 105-246 Bq/m 3 , ore 226 Ra nuclide levels are between 156.7-372.3 Bq/kg, the mean value is 222.6 Bq/kg, the maximum total radioactivity levels of mine water are total α=0.175 Bq/L and total β=0.374 Bq/L, the total radioactivity levels of drinking water is not more than total α=0.0327 Bq/L, total β=0.174 Bq/L. Conclusion: Radioactivity levels accord with the relevant national standards. There were remarkable correlation in the total radioactivity levels of mine water and drinking water. The radon concentration in well air is not up to the point of reach intervention level. (authors)

  5. Measurements of radon and chemical elements: Popocatepetl volcano

    International Nuclear Information System (INIS)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V.; Armienta, M.A.; Valdes, C.; Mena, M.; Seidel, J.L.; Monnin, M.

    2002-01-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  6. Effect of humidity on radon exhalation rate from concrete

    International Nuclear Information System (INIS)

    Yamanishi, Hirokuni; Obayashi, Haruo; Tsuji, Naruhito; Nakayoshi, Hisao

    1998-01-01

    The objective of the present study is evaluation of seasonal humidity effect on radon exhalation rate from concrete. Three concrete pieces have been placed in three different fixed humidity circumstances for about a year. The three fixed humidities are selected 3, 10, 25 g m -3 in absolute humidity, those correspond to dry condition as control, winter and summer, respectively. Radon exhalation rate from each concrete piece is measured every one month during humidity exposure. Under the lower humidity, radon exhalation rate from concrete is small. On the contrary, radon exhalation rate is large in the higher humidity circumstance. This trend is consistent with the seasonal variation of indoor air radon concentration in low air-exchange-rate room. (author)

  7. Radon emanation from soils

    International Nuclear Information System (INIS)

    Markkanen, M.; Arvela, H.

    1992-01-01

    The results of gamma spectrometric sample measurements of radon ( 222 Rn) emanation coefficients and radium concentrations ( 226 Ra) from about 800 Finnish soil samples are presented. The radon emanation rate was measured in about 400 soil samples, using radon-tight cans and Lucas cells. The effects of water content and temperature on radon emanation were investigated, using various samples of different soil types. Radon emanation and the effect of water content on radon emanation were investigated separately for different grain sizes (samples of till). The results provide some information on radon emanation in different soil types and relate emanation in laboratory conditions to conditions in ground soil. In routine measurements of radon emanation from soil samples, use of a 5% water content was considered advisable. The correction coefficients of radon emanation varied between 0.3 and 1.5, depending on the water content and soil type. At 5% water content, hardly any difference was found between radon emanation at temperatures of 20 and 1 o C. Radon emanation was found to be an inverse function of grain sizes larger than 0.5 mm in diameter. (author)

  8. Evaluation of the risk of exposure to radon

    International Nuclear Information System (INIS)

    Monchaux, G.

    2001-01-01

    The aim of this project was to assess the risk due to inhalation of radon and its decay products using a horizontal approach across a large-scale research programme. The central objective was the assessment of human risk, a task that required a combination of several programmes and involved a multidisciplinary approach. Five main topics were addressed: radioactive aerosol studies, modelling, human studies, animal studies and retrospective assessment of radon exposure. The five studies were distributed between working groups. The rationale of this project was to pool the expertise from laboratories working in different fields of radiation protection. This paper summarises the main achievements made through this multidisciplinary research programme and the synergies that occurred between the different groups. (author)

  9. Indoor radon measurements and methodologies in Latin American countries

    International Nuclear Information System (INIS)

    Canoba, A.; Lopez, F.O.; Arnaud, M.I.; Oliveira, A.A.; Neman, R.S.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R.; Osorio, A.M.; Aparecido, R.; Rodriguez, C.; Moreno, V.; Vasquez, R.; Espinosa, G.; Golzarri, J.I.; Martinez, T.; Navarrete, M.; Cabrera, I.; Segovia, N.; Pena, P.; Tamez, E.; Pereyra, P.; Lopez-Herrera, M.E.; Sajo-Bohus, L.

    2001-01-01

    According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution

  10. Radon in geological medium

    Energy Technology Data Exchange (ETDEWEB)

    Hricko, J [GEOCOMPLEX, a.s., Bratislava (Slovakia)

    1996-12-31

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a{sub v} has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km{sup 2}. The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a{sub v} > 50 kBq/m{sup 3}). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs.

  11. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  12. Radiation exposure due to radon and radon daughters

    International Nuclear Information System (INIS)

    Ullmann, W.

    1976-01-01

    Underground miners working over long periods of time in mines with a high content of radon and radon daughters belong to that group of occupationally exposed persons who are subject to the greatest somatic risk, with values especially high if the permissible dose limits are exceeded. Follwing an overview of the permissible limits currently in use for radon and radon daughters as well as the results of examinations performed in nationally-owned underground mining of the G.D.R., considerations are presented on the measuring quantities requisite for statistical, control and safety measurements in this field. Finally, conclusions are drawn concerning the measuring procedures and instruments to be employed for practical work. (author)

  13. Activity measurements of radon from construction materials

    Energy Technology Data Exchange (ETDEWEB)

    Fior, L.; Nicolosi Correa, J. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Paschuk, S.A., E-mail: spaschuk@gmail.com [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Denyak, V.V. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Schelin, H.R. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Pele Pequeno Principe Research Institute, Av. Silva Jardim, 1632, Curitiba, PR 80250-200 (Brazil); Soreanu Pecequilo, B.R. [Institute of Nuclear and Energetic Researches, IPEN, Av. Prof. Lineu Prestes, 2242-/05508-000 Sao Paulo (Brazil); Kappke, J. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil)

    2012-07-15

    This work presents the results of radon concentration measurements of construction materials used in the Brazilian industry, such as clay (red) bricks and concrete blocks. The measurements focused on the detection of indoor radon activity during different construction stages and the analysis of radionuclides present in the construction materials. For this purpose, sealed chambers with internal dimensions of approximately 60 Multiplication-Sign 60 Multiplication-Sign 60 cm{sup 3} were built within a protected and isolated laboratory environment, and stable air humidity and temperature levels were maintained. These chambers were also used for radon emanation reduction tests. The chambers were built in four major stages: (1) assembly of the walls using clay (red) bricks, concrete blocks, and mortar; (2) installation of plaster; (3) finishing of wall surface using lime; and (4) insulation of wall surface and finishing using paint. Radon measurements were performed using polycarbonate etched track detectors. By comparing the three layers applied to the masonry walls, it was concluded that only the last step (wall painting using acrylic varnish) reduced the radon emanation, by a factor of approximately 2. Samples of the construction materials (clay bricks and concrete blocks) were ground, homogenized, and subjected to gamma-ray spectrometry analysis to evaluate the activity concentrations of {sup 226}Ra, {sup 232}Th and {sup 40}K. The values for the index of the activity concentration (I), radium equivalent activity (Ra{sub eq}), and external hazard index (H{sub ext}) showed that these construction materials could be used without restrictions or concern about the equivalent dose limit (1 mSv/year). - Highlights: Black-Right-Pointing-Pointer Radon activity in air related to building materials was measured. Black-Right-Pointing-Pointer The index of activity concentration of building materials was evaluated. Black-Right-Pointing-Pointer The radium equivalent activity of

  14. BGS Radon Protective Measures GIS

    International Nuclear Information System (INIS)

    Appleton, D.; Adlam, K.

    2000-01-01

    The British Geological Survey Radon Protective Measures Geographical Information System is described. The following issues are highlighted: Identification of development sites where radon protection is required in new dwellings; Mapping radon potential on the basis of house radon and geology; Radon Protective Measures GIS; Radon site reports; and Follow-up radon protective measures sire reports

  15. Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia

    Energy Technology Data Exchange (ETDEWEB)

    Bartolo, D. de; Alberici, A.; Gallini, R.; Maggioni, T.; Mondini, A.; Zini, E. [A.R.P.A. della Lombardia, Milano (Italy); Arrigoni, S.; Cazzaniga, P.; Cugini, A.; Gallinari, G.; Olivieri, F.; Romanelli, M. [A.R.P.A. della Lombardia, Dipt. di Bergamo, Bergamo (Italy)

    2006-07-01

    Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The measurements were carried out using C.R. 39 trace detector technique. The detectors were contained in closed plastic canisters and they were positioned in situ for one year and measured each semester. The detectors were chemically treated and the traces counted using the automated optical system installed at the Radiometric Laboratory of the A.R.P.A. Department in Bergamo. The instrument accuracy and precision were evaluated using data obtained with different methods: using detectors exposed to radon known concentrations, participating to an international intercomparison as well as exposing the detector in a national calibration centre. Due to the large amount of detectors involved, a particular attention was taken for the detector homogeneity response and for the optimization of the analysis parameters. For further investigating the reliability of the measurements, two detectors were used in parallel in 10% of the tests. The results show higher values in the areas of Bergamo, Brescia

  16. World Health Organization's International Radon Project 2005-2008

    International Nuclear Information System (INIS)

    Carr, Zhanat; Shannoun, Ferid; Zielinski, Jan M.

    2008-01-01

    Recent epidemiological studies of people exposed to indoor radon have confirmed that radon in homes is a serious health hazard that can be easily mitigated. To address the issue at an international level, the World Health Organization (WHO) established the International Radon Project (IRP). The project was launched in January 2005 with its first meeting attended by 36 experts representing 17 countries. The project's scope and the key objectives were outlined at this meeting and later refined: 1-) To identify effective strategies for reducing the health impact of radon; 2-) To promote sound policy options, prevention and mitigation programs (including monitoring and evaluation of programs; 3-) To raise public, political and economical awareness about the consequences of exposure to radon (including financial institutions as target group); 4-) To estimate the global health impact of exposure to residential radon using available data on radon worldwide. WHO and its member states strive through the WHO-IRP to succeed in putting indoor radon on the environmental health agenda in countries with lower awareness of radon as a health problem and in strengthening local and national radon-related activities in countries with ongoing radon programs. Two subsequent working meetings were held: in March, 2006 in Geneva with 63 participants from 25 countries, along with representatives of the International Atomic Energy Agency (IAEA), the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP), and European Commission (EC); and in March 2007 in Munich with 61 participants from 27 countries. Both meetings reviewed the IRP progress and focused on the two main outputs: 'The WHO Report on the Global Burden of Disease (GBD) due to Radon' and 'The WHO Radon Handbook'. The former applies the WHO methodology for GBD assessment and considers ways to graphically map residential radon concentrations

  17. Molecular dynamics simulations of radon accumulation in water and oil

    Energy Technology Data Exchange (ETDEWEB)

    Pafong, Elvira; Drossel, Barbara [Institut fuer Festkoerperphysik, Technische Universitaet Darmstadt (Germany)

    2016-07-01

    Radon is a radioactive gas that can enter the human body from air or from ground water. Radon can accumulate to levels that considerably rise the risk of lung cancer while it is also known as a a treatment of various ailments, most notably rheumatoid arthritis. The accumulation of radon differs between tissues, with particularly high concentrations in fatty cells. In order to understand the mechanisms responsible for the different solubility of radon in water and fat, we perform molecular dynamics simulations of radon gas at ambient conditions in contact with a bulk material consisting either of water or oil. We evaluate the diffusion coefficient of radon in both media as well as the equilibrium concentration. The crucial point here is to understand the hydrophobic interaction between water and radon as compared to the dispersive interaction between radon and oil. Therefore, we artificially vary the water charges (i.e., the hydrophobicity) as well as the parameters of the van-der-Waals interaction.

  18. Radon Measurements in Vojvodina

    International Nuclear Information System (INIS)

    Bikit, I.; Bikit, K.; Forkapic, S.; Mrda, D.; Nikolov, J.; Todorovic, N.; Veskovic, M.

    2013-01-01

    Recent analyses of epidemiological studies of lung cancer risk from residential exposures demonstrate a statistically significant increase per unit of exposure below average annual concentrations of about 200 Bq/m 3 . Indoor radon measurements performed in Novi Sad in about 400 houses and flats are presented and discussed in this paper. By measuring gamma-activity of radon daughters, radon activity concentration was determined to be 50 Bq/m 3 . In Vojvodina region indoor radon levels were measured by alpha track detectors CR-39 on about 3000 locations during the winter seasons in the period of three years (2003-2005). The main aim of the present study was to explore the critical group of population for radon exposure and to estimate maximal annual doses. Existing radon maps which identify regions with elevated radon levels will improve data collection and analysis for the future radon campaigns. Collaboration on the JRC program of European indoor radon map and implementation of grid system are also discussed.(author)

  19. Radon and cancer

    International Nuclear Information System (INIS)

    2011-01-01

    This publication proposes an overview on what is known about the carcinogenic effect of radon. It recalls the origin of radon, its presence in the environment, and its radioactivity. It comments data on the relationship between exposure to radon and lung cancer, and with other forms of cancer. It discusses the role of the exposure level, and the cases of professional and domestic exposure with respect to these risks. It indicates the hazardous areas in France which are well identified, outlines that smokers are more likely victims of risks related to radon, that this risk is still underrated and underestimated (notably by the public). It gives an overview of existing regulations regarding exposure to radon, of public health policies and national plans concerning radon, and recalls some WHO recommendations

  20. Evaluation of lung cancer risk from radon in homes. Smoking plays the important part; Bewertung des Lungenkrebsrisikos durch Wohnungsradon. Lungenkrebsrisiko ausschliesslich durch Rauchen verursacht

    Energy Technology Data Exchange (ETDEWEB)

    Schuettmann, W.

    1999-07-01

    Studies of lung cancer risk from the beginning of the century until today are investigated and evaluated. The result shows that the risk in homes with Radon exposure is determined exclusively by the amount of smoking. Further studies of the lung cancer risk from Radon therefore should exclusively treat with non-smokers. (orig.) [German] Studien zum Lungenkrebsrisiko durch Radon vom Anfang dieses Jahrhunderts bis heute werden untersucht und bewertet. Das Ergebnis zeigt, dass das Lungenkrebsrisiko in Wohnungen mit Radonexpositionen ausschliesslich durch den Umfang des Zigarettenrauchens bestimmt wird. Untersuchungen zur Bewertung des Lungenkrebsrisikos durch Radon sollten daher ausschliesslich bei Nichtrauchern durchgefuehrt werden. (orig.)

  1. Radon as a groundwater tracer in Forsmark and Laxemar

    International Nuclear Information System (INIS)

    Grolander, Sara

    2009-10-01

    caused by the homogenous radon concentrations measured in the Laxemar area. The radon concentrations in near surface water measured in Forsmark showed large variability with both low and high radon concentrations. This large variability in radon concentration could not be explained by the flow pattern of the groundwater since no clear correlation between radon concentration and recharge/discharge classification was found. The radon concentration was also measured at different depths in the soil profile at three locations in the Forsmark area. The results showed large differences with increasing radon concentration with increasing depth. This gradient of radon concentration can be explained largely by the radon emanation potential of the local soil type at different depths. High radon concentrations were found in wells with higher radon emanation potential like till and bedrock. These observations showed the importance of the radon emanation potential of the local soil for the radon concentration in groundwater. The main purpose of this study has been to evaluate the use of radon as a tracer for groundwater flow patterns. The method is based on the ingrowth of radon from its progenitor radium according to the law of radioactive decay. According to this law the radon concentration in groundwater will reach equilibrium conditions after approximately 30 days in contact with the surrounding soil. The equilibrium radon concentration of the near surface groundwater was measured at several location in the Forsmark area and a range of the steady state radon concentration was calculated. The measured steady state radon concentration was then used to evaluate the radon concentrations measured in near surface groundwater in the area. A recharge/discharge classification of the wells was done based on the range of steady state radon concentration and the measured radon concentrations in groundwater. All wells with radon concentration below the steady state radon concentration were

  2. Soil radon monitoring in the NE flank of Mt. Etna (Sicily)

    International Nuclear Information System (INIS)

    Imme, G.; La Delfa, S.; Lo Nigro, S.; Morelli, D.; Patane, G.

    2006-01-01

    Soil radon has been monitored at a fixed location on the northeastern flank of Mt. Etna, a high-risk volcano in Sicily. The aim of this study was to evaluate the effects of the recent volcanic activity on soil radon concentration. Continuous radon measurements have been performed since July 2001. While comparison between the trend in in-soil radon concentration and the acquired meteorological series (temperature, humidity and pressure) appear to confirm a general seasonal correlation, nevertheless particular anomalies suggest a possible dependence of the radon concentration on volcanic dynamics

  3. Radon awareness in Ireland: a assessment of the effectiveness of radon road shows

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: In late 2004 the Radiological Protection Institute of Ireland (R.P.I.I.) initiated a series of radon road shows in areas designated as High Radon Areas 1 in the R.P.I.I. s national radon survey of homes. The main objective of these road shows was to provide information to a local audience on the risks of exposure to radon. These road shows target both employers and householders. Each road show has the same general format. A presentation and/or meeting with a major employer representative group within the area. The purpose is to make employers aware of the risks associated with exposure to radon in the workplace and to highlight their obligations under current Irish health and safety legislation regarding radon in the workplace. An information stand on radon manned by R.P.I.I. staff members in a local shopping centre or other similar area. This provides those concerned about radon with accessible information on radon exposure risks, how to measure radon and the steps a home owner could take to reduce radon concentrations where necessary. Where possible R.P.I.I. staff members visit one or more schools in the general area. A short presentation on radon was given to students and students were given an opportunity to asks questions Maximizing media exposure to publicize our visits is vital to the success of these visits. Each visit is preceded by a Press Release whose main aim is to brief local and national media on the radon issue so as to achieve maximum publicity mainly through radio and television coverage. In general the media are very interested in the whole radon area and R.P.I.I. staff members have given 57 radio and 10 television interviews to date since the commencement of this initiative. The four road shows carried out to date have been successful in encouraging householders to carry out radon measurements. Since the start of the road shows to the present, the R.P.I.I. has seen a 44% increase in the number of householders requesting radon

  4. Relationships between radon anomalies and seismic parameters in N-W Himalaya, India

    International Nuclear Information System (INIS)

    Walia, Vivek; Virk, H.S.; Bajwa, B.S.; Sharma, Navjeet

    2003-01-01

    Radon data accumulated during 1992-1999 in the grid (30-34 deg. N, 74-78 deg. E) in N-W Himalaya have been anlaysed vis a vis seismic data recorded in the same area, supplied by Indian Meteorological Department (IMD) network. In general, there is a positive correlation between the total radon emission and the microseismicity in the area under investigation. The earthquake magnitude has moderate positive correlation with epicentral distance and low positive correlation with amplitude of radon precursory signal, whereas both show low negative correlation between them. Empirical scaling relations are proposed using the best fit straight line from the log-linear graphs between magnitude of the events and log of the product of amplitude of radon anomaly and epicentral distance. The error between the recorded and calculated magnitude is also taken into account. The error range is higher at lower epicentral distances and magnitudes, showing that the local geology and tectonics have predominant influence on radon signals

  5. Recommended action levels for radon in dwellings

    International Nuclear Information System (INIS)

    1988-01-01

    The recommendation made by a group appointed by the Directorate of Public Health, arrives at the conclusion that radon in Norwegian dwellings implies a substantial health problem for the country. For this reason it is recommended that actions should be taken to reduce the radiation exposure from radon in Norway. Upper levels for such actions are set to 200 Bq/m 3 (radon in air of dwellings) for new contructions. For existing dwellings having concentrations of 200 - 800 Bq/m 3 , simple and unexpensive remedial actions to reduce levels are sufficient. When levels exceed 800 Bq/m 3 , more elaborate and costly actions are necessary. An evaluation of the extent of the radon problem in Norway is included, together with a survey of the cost and benefit involved in choosing various levels for remedial actions

  6. Project Radon

    International Nuclear Information System (INIS)

    Ekholm, S.

    1988-01-01

    The project started in March 1987. The objective is to perform radon monitoring in 2000 dwellings occupied by people employed by State Power Board and to continue to contribute to the development of radon filters. The project participates in developing methods for radon measurement and decontamination and in adapting the methods to large scale application. About 400 so called radon trace measurements (coarse measurement) and about 10 action measurements (decontamination measurement) have been made so far. Experience shows that methods are fully applicable and that the decontamination measures recommended give perfectly satisfactory results. It is also established that most of the houses with high radon levels have poor ventilation Many of them suffer from moisture and mould problems. The work planned for 1988 and 1989 will in addition to measurements be directed towards improvement of the measuring methods. An activity catalogue will be prepared in cooperation with ventilation enterprises. (O.S.)

  7. Development and evaluation of global radon transport model

    International Nuclear Information System (INIS)

    Kojima, H.; Nagano, K.

    2003-01-01

    The radioactive noble gas Radon-222 ( 222 Rn) is chemically inert and is removed only by radioactive decay (T1/2=3.8 d). Its primary source is uniformly distributed over the continents and the ocean represents a secondary source of atmospheric 222 Rn. The strong contrast in source strength between continents and the ocean makes 222 Rn an ideal marker of continental air masses. Because of its simple properties, the temporal and spatial distribution of 222 Rn in the troposphere is straightforward to simulate by means of atmospheric transport models. The simulation provides an intuitive visualization of the complex transport characteristics and more definite proof of phenomenon. In this paper, we present the results of an exploratory study, in which we investigated the performance of a three-dimensional transport model of the global troposphere in simulating the long range transport of 222 Rn. The transport equation has been solved by a numerical procedure based on some boundary conditions. The model structure which we have originally developed, has a horizontal resolution of 2.5deg in latitude and 2.5deg in longitude, and 10 layers in the vertical dimension. The basic computational time step used in the model runs was set to 5 min. The simulations described in this article were performed by means of a transport model driven by global objective analytical data of a time resolution of 6 h, supplied by the Japan Meteorological Agency. We focus on the west of North Pacific Ocean, were the influence of air pollution from an Asian Continent and the Japan Islands was received. For simulation experiments, radon data from some shipboard measurements on the North Pacific Ocean have been used in the present study. Figure shows time series of model prediction with different latitude distributions of radon exhalation rate and measured radon data. We find that our model consistently produce the observation. We will discuss the characteristics of the temporal and special

  8. Radon in large buildings: The development of a protocol

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the US Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed

  9. Multidimensional simulation of radon diffusion through earthen covers

    International Nuclear Information System (INIS)

    Mayer, D.W.; Gee, G.W.

    1983-01-01

    The purpose of this report is to document applications of the RADMD model used at PNL to perform analyses of radon diffusion through uranium mill tailings cover systems. The accuracy of the numerical formulation of the RADMD model was demonstrated through a comparison with a two-dimensional analytic solution to the radon diffusion equation. Excellent agreement was obtained between two-dimensional radon concentration profiles predicted by RADMD and those obtained with the analytic solution. A simulation was made of radon diffusion into a test canister using the two dimensional capabilities of RADMD. The radon flux profile was computed and illustrates the effects of the canister on the surface radon flux. The influence of the canister on the radon flux was shown to be significant under certain circumstances. Defects in earthen cover systems were evaluated using the three dimensional capabilities of RADMD. The results support the expectation that defective covers can increase the surface flux from a covered talings pile. Compared to a cover with no defects, radon flux could be elevated by as much as a factor of three when 20% of the radon control layer area contained pockets of reduced moisture. The effects of temporal and spatial variations in moisture content have been modeled by coupling RADMD with a variable saturated flow model. Two dimensional simulations were made of the time dependence of radon flux from a tailings site before and after cover placement. The results demonstrated the expected flux reduction produced by a thick earthen cover. Time dependence of the radon flux after cover placement was attributed to slight changes in moisture content of the cover material with time. The particular cover studied had a compacted clay layer that effectively attenuated the radon

  10. Developmental toxicology of radon exposures

    International Nuclear Information System (INIS)

    Sikov, M.R.; Cross, F.T.; Mast, T.J.; Palmer, H.E.; James, A.C.; Thrall, K.D.

    1992-01-01

    Concerns about hazards associated with radon exposure in dwellings may be especially relevant to pregnant women, many of whom spend substantial amounts of time in their homes. There are few data concerning the placental transfer and fetoplacental distribution of inhaled radon and decay products or their effects on the conceptus. We performed a study in rats to determine if prenatal effects could be produced by prolonged inhalation exposures to high concentrations of radon throughout gestation. A group of 43 pregnant rats was exposed 18 h d -1 , at a rate of 124 working level months (WLM) per day, from 6 to 19 days of gestation (dg), of radon and daughters adsorbed onto ore dust. A group of 26 pregnant rats from the same shipment was exposed to a filtered-air atmosphere as controls. At 20 dg, the rats were removed from the chambers, killed, and necropsied. The fetuses were evaluated for the presence of toxic effects, which included detailed teratology protocols. These exposures did not produce detectable reproductive toxicity nor teratogenic change. Two other rats were removed from the radon chambers during the last day of exposure, and their tissues were analyzed to determine the distribution of radioactivity and for dosimetry. Samples from these rats suggested that the dose rates to the placenta were roughly threefold those to the fetus but were similar to those to the liver and femur of the pregnant rats. These data indicate that the dose to the conceptus from the decay of placentally transferred radon and its progeny is more important than the contribution of translocated decay products. Translocated radon decay products are an important source of radiation doses to placental structures, however, and may have most of the radioactivity content at birth

  11. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  12. Radon reduction in waterworks

    International Nuclear Information System (INIS)

    Raff, O.; Haberer, K.; Wilken, R.D.; Funk, H.; Stueber, J.; Wanitschek, J.; Akkermann-Kubillus, A.; Stauder, S.

    2000-01-01

    The removal of radon from water using water aeration is one of the most effective methods for reducing radon in waterworks. Therefore, this report describes investigations on packed tower columns and shallow aeration devices and a method for mathematical modelling of gas exchange processes for dimensioning packed tower columns for radon removal. Moreover, possibilities for removing radon using active carbon filtration under waterworks typical conditions and for reducing indoor radon levels in waterworks are discussed. Finally, conclusions on the necessity of radon removal in German waterworks are drawn. (orig.) [de

  13. Psychosocial aspects of Czech Radon Programme

    International Nuclear Information System (INIS)

    Fojtikova, I.; Neznal, M.; Hrdy, L.

    2004-01-01

    In November 1999 a radon awareness survey was conducted among Czech republic residents to evaluate their general awareness and the factual knowledge about radon, radon measurements and radon mitigation. This survey, however, did not provide any detailed information on whether the respondents' knowledge is deep and structured or it is just a chaotic mixture of impressions. Therefore, a new survey was conducted from May to November 2001. About 20 respondents, in whose houses the long term testing for radon levels had just been finished, were interviewed. The in-depth interviews had several main aims: a) to obtain a more detailed understanding of their general awareness and factual knowledge about radon; b) to learn more about the sources of their knowledge and of their perception of the radon risk; c) to get information as to whether householders accept radon remediation, and to identify any personal, attitudinal or other variables that can influence the householder's decision; and d) to experience the direct risk communication and conceive its effectiveness. The interviews confirmed some results of the former quantitative study, e.g. increasing knowledge correlating with increasing education level. They showed that the public, overloaded with information, is not disposed to search actively for other information sources (e.g. on the Internet). People perceive their knowledge as adequate and sufficient. Their approach to gathering information is very passive. Therefore, to enhance public understanding of radiation phenomena it is necessary to make efforts, including the use of public media, otherwise radioactivity will remain shrouded in myths. These myths often lead to underestimation of the radon risk. A typical example of such underestimation is a contention that there exist long-aged healthy people who live in extreme radon concentrations. Together with the interviews, a questionnaire describing 11 presumably risky situations or practices was used. Among other

  14. Air pollution. Actions to promote radon testing

    International Nuclear Information System (INIS)

    Guerrero, Peter F.; Adams, Charles M.; McGee, William F.; Goldsmith, Larry A.; Feldesman, Alice G.; Grissinger, Charles R.; Updegraff, William D.; Langdon, Robin S.; Bartholomew, Philip L.

    1992-12-01

    To promote radon testing, EPA initiated public information and awareness programs and provided grants to states to develop programs aimed at encouraging homeowners to test for radon. Nationwide telephone surveys, according to EPA, indicate that these efforts have raised the public awareness of radon to as high as 78 percent but that about only 9 percent of those surveyed have tested their homes for radon. Concerned about improving risk reduction through its radon program, EPA convened a review panel. The panel not only recommended in May 1992 that the current voluntary approach be continued but also called for program changes to encourage more testing. These changes include targeting public information and other resources to areas where radon levels are predicted to be high and promoting testing and mitigation at the time of real estate transactions. To support state radon efforts, the Congress authorized a grant program for yearly grants of $10 million for 3 years. Funds for this program were recently extended for a fourth year through fiscal year 1993. Information to measure states' success in promoting testing by homeowners was generally not available because (1) much of the grant funding has been used to identify the extent of the radon problem; (2) federally funded public information projects were often directed to large audiences, making it difficult to measure testing rates; and (3) EPA's evaluation process for the grant program did not contain a component to measure increases in testing. We did, however, identify some state projects that have increased radon testing by targeting program efforts to homes in areas with potentially high levels of radon. The results of the state projects would seem to support the EPA review panel's recommendations on promoting radon testing through targeting program resources. In two states we surveyed, the voluntary use of disclosure statements as part of a real estate sales contract was a frequent occurrence, and in one state

  15. Radon in soil gas

    International Nuclear Information System (INIS)

    Rector, H.E.

    1990-01-01

    This paper presents the results of a technology review conducted to identify and organize the range of options for measuring radon in soil gas as a means to evaluate radon exposure potential in buildings. The main focus of the review includes identifying the following: Measurement of objectives - the specific parameter(s) that each technology is designed to measure( e.g., soil gas concentration, flux density, etc.); Equipment needs -commercial availability of systems and/or components, specifications for fabricated components; Procedural information - documented elements of field and laboratory methodology and quality assurance; Underlying assumptions - conceptual and mathematical models utilized to convert analytical outcomes to estimators of radon. Basic technologies and field data were examined from a generic perspective (e.g., the common denominators of passive detectors, hollow sampling probes, flux monitors)( as well as specific configurations developed by individual investigators (e.g., sample volume, depth) to develop the basis for separating analytical uncertainties form sampling uncertainties

  16. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  17. American Lung Association's radon public information program

    International Nuclear Information System (INIS)

    McCurdy, L.E.

    1992-01-01

    The American Lung Association (ALA), the nation's oldest voluntary health organization, is dedicated to the conquest of lung disease and the promotion of lung health. The objective of the ALA Radon Public Information Program is to reduce public exposure to elevated indoor radon levels through implementing grassroots-based radon public awareness campaigns by 22 local ALA groups. The program, which is funded by a grant from the US Environmental Protection Agency (EPA), was initiated in December 1989; the first phase will continue until May, 1991. Activities of local Lung Associations include distribution of free or reduced-cost radon kits; presenting programs in elementary and secondary schools; presenting information on TV news series and talk shows, and on radio Public Service Announcements and talk shows; presenting articles and feature stories in the print media; holding conferences, workshops, and displays at fairs and other exhibitions; distributing radon fact sheets through libraries and utility company mailings; and distributing videos through video chains and libraries. The local Lung Associations also serve as promoters for the EPA/Advertising Council Radon Public Service Announcement Campaign. We will highlight the activities of the groups in communicating radon health risks to the public; we will describe the results obtained and will attempt to evaluate the merits of the various approaches on the basis of the initial results

  18. Orphan radon daughters at Denver Radium site

    International Nuclear Information System (INIS)

    Holub, R.F.; Droullard, R.F.; Davis, T.H.

    1992-01-01

    During 18 mo of sampling airborne radioactively at a National Priority List (open-quotes Superfundclose quotes) site in metroPOlitan Denver, Bureau of mines personnel discovered radon daughters that are not supported by the parent radon gas. We refer to them as open-quotes orphanclose quotes daughters because the parent, radon, is not present in sufficient concentration to support the measured daughter products. Measurements of the open-quotes orphanclose quotes daughters were made continuously, using the Bureau-developed radon and working-level (radon-daughter) monitors. The data showed high equilibrium ratios, ranging from 0.7 to 3.5, for long periods of time. Repeated, high-volume, 15-min grab samples were made, using the modified Tsivoglou method, to measure radon daughters, to which thoron daughters contributed 26 ± 12%. On average 28 ± 6% of the particulate activity was contributed by thoron daughters. Most samples were mixtures in which the 218 Po concentration was lower than that of 214 Pb and 214 Bi, in agreement with the high-equilibrium factors obtained from the continuous sampling data. In view of the short half-life of radon progeny, we conclude that the source of the orphan daughters is not far from the Superfund sites. The mechanism of this phenomenon is not understood at this time, but we will discuss its possible significance in evaluating population doses

  19. Aerosol particle size distribution in building and caves: impact to the radon-related dose evaluation

    International Nuclear Information System (INIS)

    Berka, Z.; Thinova, L.; Brandejsova, E.; Zdimal, V.; Fronka, A.; Milka, D.

    2004-01-01

    The results of evaluation of the aerosol particle size spectra observed in the Bozkov cave are presented and compared with the spectra observed in residential areas. The radon-to-dose conversion factor is discussed, as is the correction factor referred to as the cave factor. (P.A.)

  20. Background radon levels in Germany and how to take them into account in radiological evaluations

    International Nuclear Information System (INIS)

    Gehrcke, K.; Kuemmel, M.; Dushe, C.

    2008-01-01

    A mean background radon level of 9 ±, 1 Bq/m 3 was determined for Germany as a whole. This value is lower by about 5 Bq/m3 compared to previous, less representative measurements. For 17 former mining areas in the east of Germany representative regional background levels were derived. Characteristic limits (decision thresholds and detection limits) were determined for these areas to facilitate statistically sound decisions in the radiological evaluation of mining legacies. The detection limits for the anthropogenic contribution to the radon concentration vary from 10 to more than 20 Bq/m 3 in the different mining areas. Especially the higher values are governed by the spatial and temporal variability of the background concentrations rather than measurement uncertainties. The fact that man-made contributions of partly more than 20 Bq/m3 cannot be detected with sufficient statistical accuracy has to be taken into account in radiological investigations and evaluations of mining legacies. (author)(tk)

  1. Indoor radon measurements and radon prognosis for the province of Kymi, southeastern Finland

    International Nuclear Information System (INIS)

    Pennanen, M.; Maekelaeinen, I.; Voutilainen, A.

    1996-12-01

    The purpose of the regional radon prognosis is to classify areas with different levels of radon risk. The radon prognosis gives the percentages of future homes expected to have indoor radon concentrations exceeding the levels of 200 and 400 Bq/m 3 . It is assumed that no protection against the entry of radon is used in construction. In this study about 5900 indoor radon measurements made in single family houses, semi-detached houses and row houses were used. Data on the location, geology and construction of buildings were determined from maps and questionnaires. An empirical statistical model, the adjusted indoor radon measurements and geological data were used to assess the radon risk from soil and bedrock in different areas. The building sites of the province of Kymi were divided into thirteen sub-areas. The radon prognosis are calculated for the most radon-prone foundation types including 1) houses with a slab-on-grade and 2) houses with a basement or hillside houses with open stairwells between basement and first floor. The radon levels are generally greater in the western part of the area. The radon risk is highest in gravel-dominated esker areas in southwestern, western (in Pyhtaa, Kotka, Anjalankoski, litti, Valkeala) and central (Taipalsaari) parts of the area. The radon risk is also high in some bedrock and till areas, also in southwestern and western parts of the area. In these areas the level of 200 Bq/m 3 will be exceeded in 80 % of new houses. About half of the future houses in these areas will have indoor radon concentrations exceeding 400 Bq/m 3 . The radon risk is lowest in the eastern part of the province of Kymi in every soil type. In this area the level of 200 Bq/m 3 will be exceeded in 30 % of new houses. Below 10 % will exceed 400 Bq/m 3 . (orig.) (14 refs.)

  2. Indoor radon levels in schools of South-East Italy

    International Nuclear Information System (INIS)

    Trevisi, Rosabianca; Leonardi, Federica; Simeoni, Carla; Tonnarini, Sabrina; Veschetti, Miriam

    2012-01-01

    A survey was conducted to evaluate average levels of indoor radon and gamma doses in all educational buildings (506 schools) located in South-East Italy (the Salento peninsula, province of Lecce). In this paper the final findings relating to measurements performed with SSNTD dosemeters in 438 schools (86% of the sample) are reported. The average annual activity concentration of radon in schools located in the province of Lecce is 209 ± 9 Bq/m 3 . Radon values actually ranged from 21 Bq/m 3 to 1608 Bq/m 3 . About 7% of schools showed radon concentration values above 500 Bq/m 3 , the Italian action level for workplaces. - Highlights: ► The annual radon concentration in schools of the province of Lecce is 209 ± 9 Bq/m 3 . ► Schools radon values (209 ± 9 Bq/m 3 ) are higher than the regional average (52 ± 2 Bq/m 3 ). ► Nursery schools showed higher radon values. ► Nursery schools had the highest percentage of schools (12%) over 500 Bq/m 3 .

  3. High radon exposure in a Brazilian underground coal mine

    International Nuclear Information System (INIS)

    Veiga, L H S; Melo, V; Koifman, S; Amaral, E C S

    2004-01-01

    The main source of radiation exposure in most underground mining operations is radon and radon decay products. The situation of radon exposure in underground mining in Brazil is still unknown, since there has been no national regulation regarding this exposure. A preliminary radiological survey in non-uranium mines in Brazil indicated that an underground coal mine in the south of Brazil had high radon concentration and needed to be better evaluated. This paper intends to present an assessment of radon and radon decay product exposure in the underground environment of this coal mining industry and to estimate the annual exposure to the workers. As a product of this assessment, it was found that average radon concentrations at all sampling campaign and excavation sites were above the action level range for workplaces of 500-1500 Bq m -3 recommended by the International Commission on Radiological Protection-ICRP 65. The average effective dose estimated for the workers was almost 30 times higher than the world average dose for coal miners

  4. Radon contents in groundwater and the uncertainty related to risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Masami [Kyoto Univ. (Japan)

    1997-02-01

    The United States has proposed 11 Bq/l (300 pCi/l) as the maximum contaminant levels (MCLs) of radon. Japan has not set up the standards for drinking water. The problems about evaluation of effects of radon on organism and MCLs of radon in groundwater and drinking water in 12 countries were reported. The local area content the high concentrations of radon, but generally it`s low levels were observed in Nigeria, China and Mexico. The countries which content high concentration of radon were Greek, Slovakia, Bornholm Island and Scotland. There are high and low concentration area in US and Japan. I proposed an uncertainty scheme on risk assessment for the exposure by radon. (S.Y.)

  5. Radon in workplaces

    International Nuclear Information System (INIS)

    Reichelt, A.; Lehmann, K.-H.; Reineking, A.; Porstendoerfer, J.; Schwedt, J.; Streil, T.

    2000-01-01

    The radiological assessment of the results of radon measurements in dwellings is not automatically applicable to workplaces due to different forms of utilization, constructional conditions, time of exposure, heating and ventilation conditions, additional aerosol sources, aerosol parameters, chemical substances, etc. In order to investigate the peculiarities of the radon situation in workplaces located inside buildings compared with that in dwellings, long-time recordings of radon, attached radon progeny and unattached radon progeny concentrations ( 218 Po, 214 Pb, 214 Bi) are carried out at several categories of workplaces (e.g. offices, social establishments, schools, production rooms, workshops, kitchens, agricultural facilities). 36 workplaces have been investigated. There have been carried out at least 2-3 long-time recordings for each workplace during different seasons. At the same time the gamma dose rate, meteorological conditions, aerosol particle concentrations have been registered. Many special dates from the workplaces and the buildings have been recorded. Activity size distribution of the aerosol-attached and unattached fraction of short-lived radon decay products have been determinated in 20 workplaces. Mainly the following measurement systems were used: Radon- and Radon Progeny Monitor EQF 3020, SARAD GmbH, Germany. Alpha-Track Radon Detectors, BfS Berlin, Germany. Screen Diffusion Batteries with Different Screens, University of Goettingen, Germany. Low-Pressure Cascade Impactor, Type BERNER. Condensation Nuclei Counter, General Electric, USA. PAEC-f p -Rn-Monitor, University of Goettingen, Germany. Through the measurements, many peculiarities in the course of the radon-concentration, the equilibrium factor F, the unattached fraction f p and the activity size distribution have been determined. These amounts are influenced mainly by the working conditions and the working intervals. The influence of these peculiarities in workplaces on the dose have

  6. Public perceptions of radon risk

    International Nuclear Information System (INIS)

    Mainous, A.G. III; Hagen, M.D.

    1993-01-01

    Since 1984, a significant amount of media attention has focused on health threats from radon gas exposure. Using a probability telephone survey of adults (n = 685), we studied public perceptions of risk from radon exposure versus other environmental health risks. The results indicated that 92% of those individuals who had heard of radon believe radon to be a health risk, although only 4% believe they are currently exposed to high levels of radon gas. Perception of risk from radon was positively related to other perceptions of environmental risks. Younger and less educated individuals were more likely to perceive radon as a health risk. Women were three-and-one-half times as likely as men to perceive risk from radon. However, there was no significant relationship between perceived risk from radon and cigarette smoking. Media attention has apparently led to public awareness of radon hazards, but further attention is needed to improve smokers' awareness of their special risks from radon

  7. Radon Research Program, FY 1991

    International Nuclear Information System (INIS)

    1992-03-01

    The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny as well as to provide information useful in radon control strategies. Results generated under the Program were highlighted in a National Research Council report on radon dosimetry. The study concluded that the risk of radon exposure is 30% less in homes than in mines. This program summary of book describes the OHER FY-1991 Radon Research Program. It is the fifth in an annual series of program books designed to provide scientific and research information to the public and to other government agencies on the DOE Radon Research Program

  8. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  9. Environmental radon

    International Nuclear Information System (INIS)

    Majumdar, S.K.; Schmalz, R.F.; Miller, E.W.

    1990-01-01

    This book covers many aspects of environmental radon, including: historical perspectives; occurrence and properties; detection, measurement, and mitigation, radon and health; and political, economic, and legislative impacts

  10. Predictors of Indoor Radon Concentrations in Pennsylvania, 1989-2013.

    Science.gov (United States)

    Casey, Joan A; Ogburn, Elizabeth L; Rasmussen, Sara G; Irving, Jennifer K; Pollak, Jonathan; Locke, Paul A; Schwartz, Brian S

    2015-11-01

    Radon is the second-leading cause of lung cancer worldwide. Most indoor exposure occurs by diffusion of soil gas. Radon is also found in well water, natural gas, and ambient air. Pennsylvania has high indoor radon concentrations; buildings are often tested during real estate transactions, with results reported to the Department of Environmental Protection (PADEP). We evaluated predictors of indoor radon concentrations. Using first-floor and basement indoor radon results reported to the PADEP between 1987 and 2013, we evaluated associations of radon concentrations (natural log transformed) with geology, water source, building characteristics, season, weather, community socioeconomic status, community type, and unconventional natural gas development measures based on drilled and producing wells. Primary analysis included 866,735 first measurements by building, with the large majority from homes. The geologic rock layer on which the building sat was strongly associated with radon concentration (e.g., Axemann Formation, median = 365 Bq/m3, IQR = 167-679 vs. Stockton Formation, median = 93 Bq/m3, IQR = 52-178). In adjusted analysis, buildings using well water had 21% higher concentrations (β = 0.191, 95% CI: 0.184, 0.198). Buildings in cities (vs. townships) had lower concentrations (β = -0.323, 95% CI: -0.333, -0.314). When we included multiple tests per building, concentrations declined with repeated measurements over time. Between 2005 and 2013, 7,469 unconventional wells were drilled in Pennsylvania. Basement radon concentrations fluctuated between 1987 and 2003, but began an upward trend from 2004 to 2012 in all county categories (p Pennsylvania, 1989-2013. Environ Health Perspect 123:1130-1137; http://dx.doi.org/10.1289/ehp.1409014.

  11. Distribution of indoor radon levels in Mexico

    CERN Document Server

    Espinosa, G; Rickards, J; Gammage, R B

    1999-01-01

    Our laboratory has carried out a systematic monitoring and evaluation of indoor radon concentration levels in Mexico for ten years. The results of the distribution of indoor radon levels for practically the entire country are presented, together with information on geological characteristics, population density, socioeconomic levels of the population, and architectural styles of housing. The measurements of the radon levels were made using the passive method of nuclear tracks in solids with the end-cup system. CR-39 was used as the detector material in combination with a one-step chemical etching procedure and an automatic digital- image counting system. Wherever a high level was measured, a confirming measurement was made using a dynamic method. The results are important for future health studies, including the eventual establishment of patterns for indoor radon concentration, as it has been done in the USA and Europe.

  12. EPA'S strategy to reduce risk of radon

    International Nuclear Information System (INIS)

    Page, S.

    1993-01-01

    The Indoor Radon Abatement Act of 1988 (IRAA) directed EPA to undertake a variety of activities to address the growing public concern over dangers posed by exposure to indoor radon. Among other requirements, the law directed the Agency to study radon levels, evaluate mitigation methods, establish proficiency programs, assist states with program development, develop training centers, and provide public information. EPA has developed and implemented programs to address each of the key provisions of this statute. This paper presents EPA's broad national strategy to reduce radon risks. It combines and reinforces EPA's basic foundation, including its guiding policies and cooperative partnerships, with an overall management approach and focus for the future. The paper starts with an overview that introduces the strategy's four key elements: underlying policies and scientific principles, a decentralized system of states and other partners for targeting the public, multiple strategies for achieving radon risk reduction, and a strong focus on five key program priorities. This paper then discusses each of these elements in more detail and describes how they interact to guide future efforts and directions of the Agency

  13. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  14. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  15. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  16. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  17. Design and investigation of a continuous radon monitoring network for earthquake precursory process in Great Tehran

    International Nuclear Information System (INIS)

    Negarestani, A.; Namvaran, M.; Hashemi, S.M.; Shahpasandzadeh, M.; Fatemi, S.J.; Alavi, S.A.; Mokhtari, M.

    2014-01-01

    Earthquakes usually occur after some preliminary anomalies in the physical and chemical characteristics of environment and earth interior. Construction of the models which can explain these anomalies, prompt scientists to monitor geophysical and geochemical characteristics in the seismic areas for earthquake prediction. A review of studies has been done so far, denoted that radon gas shows more sensitivity than other geo-gas as a precursor. Based on previous researches, radon is a short-term precursor of earthquake from time point of view. There are equal experimental equations about the relation between earthquake magnitude and its effective distance on radon concentration variations. In this work, an algorithm based on Dobrovolsky equation (D=10 0.43M ) with defining the Expectation and Investigation circles for great Tehran has been used. Radon concentration was measured with RAD7 detector in the more than 40 springs. Concentration of radon in spring, spring discharge, water temperature and the closeness of spring location to active faults, have been considered as the significant factors to select the best spring for a radon continuous monitoring site implementation. According to these factors, thirteen springs have been selected as follow: Bayjan, Mahallat-Hotel, Avaj, Aala, Larijan, Delir, Lavij, Ramsar, Semnan, Lavieh, Legahi, Kooteh-Koomeh and Sarein. (author)

  18. Radon concentration levels in Fatima Jinnah women university Pakistan

    International Nuclear Information System (INIS)

    Khan, S.A.; Ali, S.; Tufail, A.; Qureshi, A.A.

    2005-01-01

    Public exposure to radioactive gas radon and its progeny present in the air results in the largest contribution to total effective dose received by human beings. It is therefore of great concern to monitor radon concentration in energy conserved air tight buildings. Measurements of radon in the Fatima Jinnah Women University (FJWU) have been carried out for investigation and comparison of radon concentration in the new and old buildings of the campus at Rawalpindi, Pakistan. The study was done because according to the international guidelines concerning environmental problems, it is necessary to evaluate and know the radon levels, especially since most of the natural radiation dose to human beings comes from radon gas and its progeny. Solid State Nuclear Track Detectors (SSNTDs) being efficient, therefore, the measurements were carried out by passive, time integrated method, using CR-39 detector in polythene bags. The detectors were exposed for more than six month in various locations indoors and outdoors. The detectors were etched using NaOH, the tracks were counted manually, and the track density was converted to radon concentration. Radon concentration varied from 31 to 213 Bq.m -3 in old building and from 27 to 143 Bq.m -3 in new buildings, showing slight elevated values in the old buildings. Radon concentration values were found to be less than the values quoted by radiation protection agencies. Radiation dose due to radon varied in the university campus depending on occupancy factor. (author)

  19. Radon exposure at specific workplaces in Austria experiences and future challenges

    International Nuclear Information System (INIS)

    Gruber, V.; Ringer, W.

    2017-01-01

    Radon exposure at specific workplaces like water works, radon spas, tourist mines and show caves were evaluated in Austria within pilot studies (2004-10) and have been regulated in an ordinance since 2008. In this article, the major results and experiences in radon measurements and dose assessments at those workplaces by the accredited AGES laboratory are presented. (authors)

  20. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation; Misure di esposizione ai prodotti di decadimento del radon a breve vita tramite uno spettrometro alfa per la misura dell'attivita' del particolato atmosferico indoor e valutazioni dosimetriche

    Energy Technology Data Exchange (ETDEWEB)

    Berico, M.; Castellani, C.M.; Formignani, M. [ENEA, Divisione Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche Ezio Clementel, Bologna (Italy); Mariotti, F. [Bologna Univ., Bologna (Italy). Dipt. di Fisica

    2001-07-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F{sub e}q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F{sub e}q, f{sub p}) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented. [Italian] L'esposizione a radon in ambiente lavorativo e la conseguente inalazione dei suoi prodotti di decadimento in forma particolata e' oggetto di una recente normativa italiana in materia di protezione dalle radiazioni ionizzanti. Per rispondere a questa necessita', presso l'Istituto per la Radioprotezione dell'ENEA di Bologna e' stato progettato e realizzato uno spettrometro alfa per la misura della progenie del radon con la finalita' di valutare, su brevi periodi di tempo, la concentrazione individuale dei suoi prodotti di decadimento e, con l'impiego di batterie a diffusione a reti, consentire inoltre la discriminazione della concentrazione della frazione attaccata e non

  1. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  2. Radon/radon-daughter measurement methods and instrumentation

    International Nuclear Information System (INIS)

    Rock, R.L.

    1977-01-01

    Radon-daughter measurement equipment and techniques have been continuously improved over the last 25 years. Improvements have been in the areas of accuracy, time and convenience. We now have miniaturized scalers and detectors available for measuring the alpha particle count rates from aerosol samples collected on filter papers. We also have small lightweight efficient pumps for conveniently collecting samples and we have various counting methods which allow us to choose between making very precise measurements or nominal measurements. Radon-daughter measurement methods used in uranium mines and mills are discussed including a personal radon-daughter-exposure integrating device which can be worn by miners

  3. Radon levels in underground workplaces: a map of the Italian regions

    International Nuclear Information System (INIS)

    Rossetti, Marta; Esposito, Massimo

    2015-01-01

    The indoor radon exposition is a widely recognised health hazard, so specific laws and regulations have been produced in many countries and so-called radon-risk maps have consequently been produced. In Italy the regulation applies to general workplaces and a national survey was carried out in the 1990's to evaluate the exposure to radon in dwellings. Failing a national coordinated mapping programme, some Italian regions performed a survey to identify radon-prone areas, nevertheless with different methodologies. In this work a national map of the average annual radon concentration levels in underground workplaces, obtained from the results of 8695 annual indoor radon measurements carried out by U-Series laboratory between 2003 and 2010, was presented. Due to underground locations, the mean radon concentration is higher than that from previous map elaborated for dwellings and a significant radon concentration was also found in Regions traditionally considered as low-risk areas. (authors)

  4. Building and environmental factors associated with elevated radon levels in rural Iowa homes

    International Nuclear Information System (INIS)

    Weih, L.M.B.

    1993-01-01

    This work examined the relationships between home construction, soil, and climatic factors with radon concentration in 585 rural Iowa homes, screened in winter of 1989. The specific goals of this work were to evaluate the utility of Soil Conservation data in describing radon occurrence in Iowa, and to assess the joint influence of construction and environmental characteristics on predicting radon concentration in homes. A follow-up study in a subset of homes evaluated the variability of radon screening measurements over time. The first part found that the relationship between radon concentration and home construction factors was dependent on location of the radon test in homes. In basements, wall construction and degree of energy efficiency predominated in predicting radon concentration. On upper floors, age of home predominated in predicting radon concentration, with a general decrease in radon concentration with age of home. The second part found that texture of the soil on which the home is located was the most important predictor of radon concentration for homes tested in basements, but the explanatory power was low. Precipitation in the year preceding screening was negatively correlated with radon concentration in homes, but the relationship was only apparent when basement wall type and soil texture were accounted for. Regional trends were not apparent except in describing the relative distribution of soil texture classes across the state. Radon concentration on upper floors of homes was not well described by either soil factors or precipitation. In 1992 a decrease of 36% and 51% from 1989 radon screening levels was found for homes tested in basements and upper floors, respectively. This data set included pair measurements of the same testing location in homes tested in winter 1989. Temperature differences were positively correlated with radon concentration and precipitation differences were not significantly associated with change in radon concentration

  5. Radon level and radon effective dose rate determination in Moroccan dwellings using SSNTDs

    International Nuclear Information System (INIS)

    Oufni, L.; Misdaq, M.A.; Amrane, M.

    2005-01-01

    Inhalation of radon ( 222 Rn) and its daughter product are a major source of natural radiation exposure. The measurement of radon activity in dwelling is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Keeping this in view, the indoor radon activity level and radon effective dose rate were carried out in the dwellings of Beni-Mellal, Khouribgra and Ben Guerir cities, Morocco, using the solid state nuclear track detectors (SSNTD) technique. Assuming an indoor occupancy factor of 0.8 and 0.4 for the equilibrium factor of radon indoors, we found that the 222 Rn effective dose rate in the studied dwellings ranges from 1.01 to 7.90mSvy -1 . The radon activity in the corresponding dwellings was found to vary from 40 to 532Bqm -3 . The radon activity has not only been found to vary with seasonal changes, but also with the age, the construction mode of houses, the ventilation conditions and with specific sites and geological materials

  6. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  7. Evaluation of radon concentration in well and tap waters in Bursa (Turkey)

    International Nuclear Information System (INIS)

    Akar Tarim, U.; Gurler, O.; Akkaya, G.; Kilic, N.; Yalcin, S.; Kaynak, G.; Gundogdu, O.

    2012-01-01

    222 Rn measurements in water samples collected from 27 wells and 19 taps that were supplied from the investigated wells were conducted using the AlphaGUARD PQ 2000PRO radon gas analyser at sites across several geologic formations within the city of Bursa (Turkey). The measured radon concentrations ranged from 1.46 to 53.64 Bq l -1 for well water and from 0.91 to 12.58 Bq l -1 for tap water. Of the 27 sites sampled, only 7 had radon levels above the safe limit of 11.1 Bq l -1 recommended by the USEPA. In general, all determined concentrations were well below the 100 Bq l -1 revised reference level proposed by the European Union. These values of radon concentrations in water samples are compared with those reported from other countries. Doses resulting from the consumption of these waters were calculated. The minimum and the maximum annual mean effective doses due to 222 Rn intake through water consumption were 0.02 μSv a -1 and 1.11 μSv a -1 , respectively. (authors)

  8. Generation and mobility of radon in soil

    International Nuclear Information System (INIS)

    1992-01-01

    Objectives of this research include: (1) To determine the processes that cause large seasonal and short-term changes in the radon (Rn) content of soil gases, and to develop methods of predicting and modeling these variations; (2) to evaluate the relation of Rn emanation coefficients to form of radium (Ra) and other U-series decay products, particularly the role of Ra in organic matter and Fe-oxides; (3) to evaluate the conditions in which convection of gas in soil and bedrock may affect soil gas radon availability in houses; and, (4) to collaborate with other DOE researchers on evaluation of Rn flux into houses, using our well characterized soil sites

  9. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  10. Radon emanation coefficients in sandy soils

    International Nuclear Information System (INIS)

    Holy, K.; Polaskova, A.; Baranova, A.; Sykora, I.; Hola, O.

    1998-01-01

    In this contribution the results of the study of an influence of the water content on the emanation coefficient for two sandy soil samples are reported. These samples were chosen on the because of the long-term continual monitoring of the 222 Rn concentration just in such types of soils and this radon concentration showed the significant variations during a year. These variations are chiefly given in connection with the soil moisture. Therefore, the determination of the dependence of the emanation coefficient of radon on the water content can help to evaluate the influence of the soil moisture variations of radon concentrations in the soil air. The presented results show that the emanation coefficient reaches the constant value in the wide interval of the water content for both sandy soil samples. Therefore, in the common range of the soil moisture (5 - 20 %) it is impossible to expect the variations of the radon concentration in the soil air due to the change of the emanation coefficient. The expressive changes of the radon concentration in the soil air can be observed in case of the significant decrease of the emanation coefficient during the soil drying when the water content decreases under 5 % or during the complete filling of the soil pores by the water. (authors)

  11. Analysis of radon protection cover on uranium tailings pile

    International Nuclear Information System (INIS)

    Zhang Zhe

    1993-01-01

    The average radon emanation rate of the whole surface over one year was used for evaluating the radon release of uranium tailings pile. The effective of radon protection cover depends on the shape and property of the tailings pile, the properties of covering and the control of air vadose in the pile. It was indicated that the covering with low diffusion coefficient, small porosity and bad permeability was suitable to cover the pile. The analytical formula of the covering layer thickness was given

  12. Tempts to determine radon entry rate and air exchange rate variable in time from the time course of indoor radon concentration

    International Nuclear Information System (INIS)

    Thomas, J.

    1996-01-01

    For the study and explanation of the diurnal variability of the indoor radon concentration a(t) [Bq/m 3 ], which is proportional to the ratio of the radon entry rate A [Bq/h] and the air exchange rate k [1/h], it would be of advantage to know separately the diurnal variability of both determining quantities A(t) and k(t). To measure directly and continuously the radon entry rate A(t) is possible only in special studies (mostly in experimental rooms) and also continuous measuring of the air exchange rate k(t) is possible also only in special studies for a short time. But continuously measuring radon meters are now common, do not trouble people in normal living regime during day and night. The goal of this endeavour would be the evaluation of the time courses of both determining quantities from the time courses of the indoor radon concentration directly without additional experimental work and so a better utilisation of such measurements. (author)

  13. Gamma, radon, natural radioactivity measurements in Chile

    International Nuclear Information System (INIS)

    Stuardo, E.

    1997-01-01

    Different natural radiation measurements, performed since 1983, are analysed and discussed regarding the average effective population dose. A decade of absorbed gamma dose measurements in air (1983-93), were carried out using compensated TLD detectors, during long periods of integration time and with a network of 11 stations, along the country, from Arica to the Antarctic territory. An indoor Rn -222 and gamma survey dwellings, in high background zones, underground mines and drinking water was started in 1988 using different kind of detectors, including electret radon chambers. The methods, dose assessments and results are presented and discussed in the frame of worldwide average effective population doses. None of the average effective doses found over the evaluated areas, exceed the comparison levels. (author)

  14. Radon atlas of Finland

    International Nuclear Information System (INIS)

    Voutilainen, A.; Maekelaeinen, I.; Pennanen, M.; Reisbacka, H.; Castren, O.

    1997-11-01

    The most efficient means of reducing indoor radon exposure is to locate and mitigate dwellings with radon concentration exceeding the action level of 400 Bq/m 3 and to build new houses so that radon concentrations do not exceed 200 Bq/m 3 . The maps and tables in this report are useful tools for those who plan and decide what kind of radon mitigation measures are needed in municipalities. STUK (The Radiation and Nuclear Safety Authority) has an indoor radon database of 52 000 dwellings, for which the indoor radon concentration and construction details are known. The building site soil type of about 38 000 dwellings is known. This atlas is a summary of all indoor radon measurements made by STUK in lowrise dwellings and in first-floor flats. The results are shown as arithmetic means of 5- or 10-km squares on maps of the provinces. Three radon maps have been made for each province. On one map the data consist of all measurements the position coordinates of which are known. On the two other maps the building sites of houses are classified into permeable and low-permeable soil types. The tables show statistics for all indoor radon measurements by municipality and building site soil type. (orig.)

  15. Scopingreport radon

    International Nuclear Information System (INIS)

    Blaauboer, R.O.; Vaas, L.H.; Hesse, J.M.; Slooff, W.

    1989-09-01

    This report contains general information on radon concerning the existing standards, sources and emissions, the exposure levels and effect levels. lt serves as a basis for the discussion during the exploratory melting to be held in November/December 1989, aimed at determining the contents of the Integrated Criteria Document Radon. Attention is focussd on Rn-222 (radon) and Rn-220 (thoron), presently of public interest because of radon gas pollution in private homes. In the Netherlands air quality standards nor product standards for the exhalation rate of building materials have been recommended. The major source of radon in the Netherlands is the soil gas (> 97%), minor sources are phosphate residues and building materials (> 2% in total). Hence, the major concern is the transfer through the inhalation of air, the lung being the most critical organ at risk to develop cancer. Compared to risks for humans, the risks of radon and its daughters for aquatic and terrestric organisms, as well as for agricultural crops and livestock, are assumed to be limited. In the Netherlands the average dose for man due to radon and thoron progeny is appr. 1.2 mSv per year, the estimated dose range being 0.1-3.5 mSv per year. This dose contributes for about 50% to rhe total exposure due to all sources of ionizing radiation. Of this dose respectively 80% is caused by radon and about 90% is received indoor. The estimated dose for the general population corresponds to a risk for inducing fatal cancers of about 15 x 10-6 per year, ranging from 1.2 x 10-6 to 44 x 10-6 which exceeds the risk limit of 1 x 10-6 per year -as defined in the standardization policy in the Netherlands for a single source of ionizing radiation-with a factor 15 (1- 44). Reduction of exposure is only possible in the indoor environment. Several techniques have been described to reduce the indoor dose, resulting from exhalation of the soil and building materials. )aut- hor). 37 refs.; 3 figs.; 8 tabs

  16. Radon - from knowledge to action: an all-around cleared issue of radiation protection?

    Energy Technology Data Exchange (ETDEWEB)

    Maringer, F.J. [Vienna Univ. of Natural Resources and Applied Life Science, BEV - Federal Office of Metrology and Surveying (Austria); Vienna Univ. of Technology, Low-Level Counting Laboratory Arsenal, Wien (Austria)

    2006-07-01

    The knowledge about radon is well established in the radiation protection world. After many decades of research work done worldwide by many radiation protection scientists and research teams, the sources and origin, the transport through the soil and into the buildings, and the radiobiological effects of radon progenies in the human respiratory tract are well known. When typing 'radon' in web search engines e.g. www.google.at about 5.1 Million hits are appearing. A countless number of papers have been published in the field of radon research and the ICRP has established radiation protection principles for radon exposure at home and at workplaces. So far, the radon issue seemed well ticked off in the scientific world of radiation protection and the scientists could give more attention to other and more newsworthy problems and questions. But this is only half the truth. The implementation of radon mitigation and precaution standards needs continuously scientific attendance and research networking on an international level. Otherwise the radon issue could degrade easily to a simplified technical and economical exercise without sustainable results in public health. In this paper the radon investigations in Austria which have been carried out in the last 20 years and the applied methods and derived standards for mitigation and precaution in the home and workplace sectors are given. The future strategy and scientific and social necessities in the radon issue are outlined comprehensively. The agreed and proposed research objectives and cooperation which seems necessary are discussed in consideration of the medium-term European radiation protection context. (authors)

  17. Radon - from knowledge to action: an all-around cleared issue of radiation protection?

    International Nuclear Information System (INIS)

    Maringer, F.J.

    2006-01-01

    The knowledge about radon is well established in the radiation protection world. After many decades of research work done worldwide by many radiation protection scientists and research teams, the sources and origin, the transport through the soil and into the buildings, and the radiobiological effects of radon progenies in the human respiratory tract are well known. When typing 'radon' in web search engines e.g. www.google.at about 5.1 Million hits are appearing. A countless number of papers have been published in the field of radon research and the ICRP has established radiation protection principles for radon exposure at home and at workplaces. So far, the radon issue seemed well ticked off in the scientific world of radiation protection and the scientists could give more attention to other and more newsworthy problems and questions. But this is only half the truth. The implementation of radon mitigation and precaution standards needs continuously scientific attendance and research networking on an international level. Otherwise the radon issue could degrade easily to a simplified technical and economical exercise without sustainable results in public health. In this paper the radon investigations in Austria which have been carried out in the last 20 years and the applied methods and derived standards for mitigation and precaution in the home and workplace sectors are given. The future strategy and scientific and social necessities in the radon issue are outlined comprehensively. The agreed and proposed research objectives and cooperation which seems necessary are discussed in consideration of the medium-term European radiation protection context. (authors)

  18. Control of respirable particles and radon progeny with portable air cleaners

    International Nuclear Information System (INIS)

    Offermann, F.J.; Sextro, R.G.; Fisk, W.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles and radon progeny. Following injection of cigarette smoke and radon in a room-size chamber, decay rates for particles and radon progeny concentrations were measured with and without air cleaner operation. Particle concentrations were obtained for total number concentration and for number concentration by particle size. In tests with no air cleaner the natural decay rate for cigarette smoke was observed to be 0.2 hr -1 . Air cleaning rates for particles were found to be negligible for several small panel-filters, a residential ion-generator, and a pair of mixing fans. The electrostatic precipitators and extended surface filters tested had significant particle removal rates, and a HEPA-type filter was the most efficient air cleaner. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in removing radon progeny. At low particle concentrations plateout of the unattached radon progeny is an important removal mechanism. Based on data from these tests, the plateout rate for unattached progeny was found to be 15 hr -1 . The unattached fraction and the overall removal rate due to deposition of attached and unattached nuclides have been estimated for each radon decay product as a function of particle concentration. While air cleaning can be effective in reducing total radon progeny, concentrations of unattached radon progeny can increase with increasing air cleaning. 39 references, 26 figures, 9 tables

  19. Low-level radon measurements by nuclear track detectors

    International Nuclear Information System (INIS)

    Koksal, E. M.; Goksel, S. A.; Alkan, H.

    1985-01-01

    In the work to be described here we have developed a passive nuclear track dosimeter to measure the integrated value of indoor radon (Rn-222) over a long period of time. Passive radon dosimeter which we have developed in our laboratories makes use of two small pieces of CR-39 plastic (Allyl diglycol carbonate) as detectors for registering tracks of alpha particles emitted by radon. These CR-39 plastic detectors are fixed on the inside bottom of a cup-shaped polystrene enclosure which is closed at the top by a tissue permeable for gases only. CR-39 detectors exposed to radon gas in the indoor air for a period of six months then are removed and chemically etched to make the alpha particle tracks visible under the microscope. The counts of tracks are evaluated to determine the radon concentration in the air in comparison with the number of tracks produced by a known concentration of radon gas. By using the passive dosimeters developed and the chemical etching procedure descriped here, measurements of indoor radon concentrations were carried out in 45 houses in different districts of the city of Istanbul. In this pilot experiment mean radon concentrations between 0.7 and 3.5 pCi/l have been found in these houses. In order to improve the counting of alpha tracks produced on the detectors a prototype electrochemical etching system in addition to chemical etching, is being developed. (author)

  20. Measurements of thoron and radon progeny concentrations in Beijing, China

    International Nuclear Information System (INIS)

    Zhang Lei; Liu Cuihong; Guo Qiuju

    2008-01-01

    It has been reported that thoron levels in China are above the world average and may therefore make a significant contribution to the natural background radiation dose. We therefore conducted a pilot study of concentrations of both thoron and radon progeny during the spring of 2006 in the Beijing area, China. A new type of portable 24 h integrating monitor with a CR-39 detector was used during the survey. Seventy dwellings and eight outdoor sites were measured during the survey. For country houses built of red bricks and slurry, the average equilibrium equivalent concentrations (EEC) of thoron and radon were 1.02 ± 0.48 and 16.41 ± 9.02 Bq m -3 , respectively, whereas for city dwellings built of cement blocks and floor slabs, the results were 0.48 ± 0.47 and 11.50 ± 6.99 Bq m -3 for thoron and radon, respectively. For outdoor air, concentrations of thoron and radon progeny were 0.29 ± 0.28 and 7.05 ± 2.68 Bq m -3 , respectively. Radiation exposures from thoron and radon progeny were also evaluated; the ratio of dose contribution from thoron progeny to that of radon progeny was evaluated to be 28% and 17% in country houses and city dwellings, respectively. (note)

  1. The effect of natural ventilation on radon and radon progeny levels in houses

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1992-01-01

    In contradiction to the widely held assumption that ventilation is ineffective as a means of reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5-10 using only natural ventilation. Measurements of the outdoor-basement pressure differential and the radon entry rate show that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes. The first mechanism is the obvious one: dilution. Radon concentrations are lowered by the addition of uncontaminated outdoor air. The second mechanism is less evident: an open basement window reduces basement depressurisation. This decreases the rate at which radon-laden soil gas is drawn into the house. It was also found that the radon entry rate is a linear function of basement depressurisation up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubles the building air exchange rate and reduces the radon entry rate by up to a factor of 5. (author)

  2. Does the new EU-BSS improve radon protection in Austria?

    International Nuclear Information System (INIS)

    Ringer, W.; Haider, W.

    2015-01-01

    The new Council Directive 2013/59/EURATOM regarding radiation protection (EU-BSS) contains comprehensive regulations regarding radon protection in dwellings, in public buildings, and at workplaces for the first time. Key elements are the specification of a reference level of maximum 300 Bq/m 3 , the establishment of a national radon action plan, and a more comprehensive regulation of radon protection at workplaces and public buildings. The radon action plan shall contain strategies and measures regarding for example the estimation of the distribution of indoor radon concentrations, the mapping of radon, the radon risk communication strategy, the assignment of responsibilities, and regular reviews of the action plan. The new EU-BSS often requires only the establishment of strategies and the specification of measures, leaving the precise content of the strategies and measures to the member states. This gives the member states flexibility for the implementation of the EU-BSS into national legislation and allows to account for specific national experiences and circumstances. This contribution discusses and evaluates - based on the existing regulations concerning radon protection in Austria - the effectiveness of different new measures and regulations with respect to reducing the radon risk in Austria. Furthermore, their feasibility and practicability in terms of administrative and financial effort will be discussed. Thus, efficient new measures which lead to an improvement of the current radon control system will be identified.

  3. Radon: A health problem and a communication problem

    International Nuclear Information System (INIS)

    Johnson, R.H.

    1992-01-01

    The US Environmental Protection Agency (USEPA) is making great efforts to alert the American public to the potential health risks of radon in homes. The news media have widely publicized radon as a problem; state and local governments are responding to public alarms; and hundreds of radon open-quotes expertsclose quotes are now offering radon detection and mitigation services. Apparently, USEPA's communication program is working, and the public is becoming increasingly concerned with radon. But are they concerned with radon as a open-quotes healthclose quotes problem in the way USEPA intended? The answer is yes, partly. More and more, however, the concerns are about home resale values. Many homebuyers are now deciding whether to buy on the basis of a single radon screening measurement, comparing it with USEPA's action guide of 4 pCi L -1 . They often conclude that 3.9 is OK, but 4.1 is not. Here is where the communication problems begin. The public largely misunderstands the significance of USEPA's guidelines and the meaning of screening measurements. Seldom does anyone inquire about the quality of the measurements, or the results of USEPA performance testing? Who asks about the uncertainty of lifetime exposure assessments based on a 1-hour, 1-day, 3-day, or even 30-day measurement? Who asks about the uncertainty of USEPA's risk estimates? Fortunately, an increasing number of radiation protection professions are asking such questions. They find that USEPA's risk projections are based on many assumptions which warrant further evaluation, particularly with regard to the combined risks of radon and cigarette-smoking. This is the next communication problem. What are these radiation professions doing to understand the bases for radon health-risk projections? Who is willing to communicate a balanced perspective to the public? Who is willing to communicate the uncertainty and conservatism in radon measurements and risk estimates?

  4. Radon og boligen

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    Radon er en radioaktiv og sundhedsskadelig luftart, som ved indånding øger risikoen for lungekræft. Der er ingen dokumenteret nedre grænse for, hvornår radon er ufarligt. Derfor anbefales det, at man tilstræber et så lavt radonindhold i indeluften som muligt. Man kan hverken lugte, se, høre eller...... smage radon, så vil du vide, om du har radon i din bolig, må du måle radonindholdet i indeluften. Radon forekommer naturligt i jorden og kan suges ind sammen med jordluft, hvis der inde er et undertryk, og hvis konstruktionerne mod jord er utætte. Jordluft trænger ind gennem revner og utætte samlinger......, fx omkring rør til kloak, vand og varmeforsyning. Koncentrationen af radon i jorden varierer meget fra sted til sted, også lokalt og gennem året. Tidligere undersøgelser har vist, at der kan forekomme høje koncentrationer i Sydgrønland, specielt i området syd for Narsalik ved Paamiut, 61°30’N....

  5. Radon campaigns. Status report 2008

    International Nuclear Information System (INIS)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-01

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m 3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m 3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m 3 was exceeded during the two first campaign seasons. Among the households that replied

  6. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. Movement of the subject to an environment with a lower radon concentration from an environment with a higher level of radon would result in an exhalation of radon, and the initial exhalation rate of radon should depend on the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. We report a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. (author).

  7. Preliminary Study for 3D Radon Distribution Modelling in the Room

    Energy Technology Data Exchange (ETDEWEB)

    Lee, ChoongWie; Kim, HeeReyoung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Radon exists in the form of noble gas, which comes from decay of {sup 238}U, becoming stable {sup 206}Pb going through 4 alpha and 4 beta decays. If this process occurred in human body after inhalation, lung could be damaged by interaction with these radiations causing lung cancer. Most radon in indoor air comes from soil (85 - 97%) through crack of the wall but it also came from wall (2 - 5%) itself in home. Due to its hazardous and unpredictable characteristic, radon became one of the concerning nuclides in indoor air. Hence, the number of survey and research about radon has been increased. Although accurate radon measurement is important to evaluate health risk, it is hard to actually achieve because radon is affected by many conditions, where its concentration can vary easily. Moreover, radon concentration can vary according to the height because of density of radon in the spatial aspect. 3D distribution modelling in the room of radon with aerodynamic features and sources variations was carried out to find average and maximum radon concentration. 3D radon distribution in the room would be find through this computational analysis and it is thought to be possible to correct measured radon concentration with spatial variation to fit the height of nose where inhalation occur. The methodological concept for 3D modelling was set up to solve transport equation for radon behavior by using computational fluid dynamics (CFD) software such as FLUENT.

  8. Radon in Africa: South African Lessons Learnt

    International Nuclear Information System (INIS)

    Simanga, A.T.

    2010-01-01

    Processing (MIMP) facilities Workers are exposed in mining to:- Radon and its progeny External Exposure (gamma) Radioactive dust Water ingestion (inadvertently) Radon: Technical Considerations Monitoring is performed to detect, quantify and compare with goals. It must be fit for purpose and monitoring plan must be developed, implemented and evaluated. Monitoring Plan A radon monitoring plan is site specific, but the basic steps are common. Basic Steps in the Plan Purpose of monitoring Monitoring strategy Survey Data Handling Quality control Concluding Remarks In radiological protection- NORM industries in particular Mining and Mineral Processing Facilities- Rn is a major contributor to exposure In Africa as more regulatory infrastructure gets set up- Radon will become a prominent issue- because mining is major. Challenge is how do we ensure that the decisions we make are: - Based on credible data to enable incredible impact - Based on credible legislative framework - Made by technically competent people

  9. Radon generation and transport. A journey though matter

    Energy Technology Data Exchange (ETDEWEB)

    Cozmuta, I. [Beckman Institute 139-74 Caltech, Pasadena, CA 91125 (United States)

    2001-12-07

    The transport of radon in concrete takes place through the complicated network of interconnected pores that is, at any time, the result of the process of hydration of cement and of moisture distribution and transport. Initially the microstructure of concrete depends on the mix proportions and curing conditions, its time-evolution being conditioned by its surrounding environment. Radon transport will be consequently a function of time, as it is influenced by the changing microstructure (total porosity and its distribution) and by the amount and distribution of the moisture contained in the pore system. A selection of information from the large amount of literature available on concrete is presented in chapter 2. A model that describes the process of hydration, of microstructure development and of moisture transport is presented in chapter 3. The physics of radon diffusion in homogeneous porous materials is outlined in chapter 4. The coupling of the numerical implementation of the hydration and radon transport (chapter 6) offers the possibility to achieve calculated values for porosity and moisture content thus, reducing the number of material parameters in the radon-transport equation that have to be determined experimentally. Chapter 7 covers the experimental methods and techniques. Chapter 5 presents a survey of the information available in literature on radon release from concrete and on radon barriers. This chapter also summarises results of several experimental studies investigating the radon reduction efficiency and also the permeability of various covers. On basis of this information, a selection was made for the covering materials to be assessed in this thesis. Radon-release rates of uncovered and completely covered concrete samples were measured. From these measurements the reduction efficiencies of various sealants (epoxy glue, double-sided aluminised polyethylene foil, soluble glass) were calculated (chapter 12). Also, as a result of the collaboration

  10. Radon generation and transport. A journey though matter

    International Nuclear Information System (INIS)

    Cozmuta, I.

    2001-01-01

    The transport of radon in concrete takes place through the complicated network of interconnected pores that is, at any time, the result of the process of hydration of cement and of moisture distribution and transport. Initially the microstructure of concrete depends on the mix proportions and curing conditions, its time-evolution being conditioned by its surrounding environment. Radon transport will be consequently a function of time, as it is influenced by the changing microstructure (total porosity and its distribution) and by the amount and distribution of the moisture contained in the pore system. A selection of information from the large amount of literature available on concrete is presented in chapter 2. A model that describes the process of hydration, of microstructure development and of moisture transport is presented in chapter 3. The physics of radon diffusion in homogeneous porous materials is outlined in chapter 4. The coupling of the numerical implementation of the hydration and radon transport (chapter 6) offers the possibility to achieve calculated values for porosity and moisture content thus, reducing the number of material parameters in the radon-transport equation that have to be determined experimentally. Chapter 7 covers the experimental methods and techniques. Chapter 5 presents a survey of the information available in literature on radon release from concrete and on radon barriers. This chapter also summarises results of several experimental studies investigating the radon reduction efficiency and also the permeability of various covers. On basis of this information, a selection was made for the covering materials to be assessed in this thesis. Radon-release rates of uncovered and completely covered concrete samples were measured. From these measurements the reduction efficiencies of various sealants (epoxy glue, double-sided aluminised polyethylene foil, soluble glass) were calculated (chapter 12). Also, as a result of the collaboration

  11. Radon Mapping of the Osijek Town

    International Nuclear Information System (INIS)

    Radolic, V.; Faj, Z.; Smit, G.; Culo, D.; Planinic, J.

    1998-01-01

    After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m -3 , standard deviation of 44.0 Bq m -3 and geometric mean of 60.1 Bq m -3 , for the radon concentration range from 23 to 186 Bq m -3 . The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m -3 , was in accordance with the theoretical log-normal distribution which was shown with χ 2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that showed the positive correlation between radon concentrations in the soil and indoors. Radon measurements in Osijeks primary schools pointed out a school that had the highest radon concentration (300 Bq m -3 ) considering all the former indoor radon measurements. The radon distribution in the school building was investigated afterwards radon mitigation procedures were undertaken. (author)

  12. The effect and the amendment of thermoregulation to the stability of radon concentration in radon chamber

    International Nuclear Information System (INIS)

    Zhang Xiongjie; Wang Renbo; Qu Jinhui; Tang Bin; Zhu Zhifu; Man Zaigang

    2010-01-01

    When the temperature in the airtight radon chamber was adjusted, it would induce the frequent changes of the air pressure in chamber, then the radon concentration in the radon chamber would continuously reduce, which could seriously destroy the stability of the radon concentration in radon chamber. In this paper, on the study of the effect reasons to the stability of radon concentration in airtight radon chamber due to the thermoregulation, a new amendment scheme was put forward, and the solutions of the relevant parameters were discussed. The amendment scheme had been successfully applied to HD-6 radon chamber, and achieved good results. (authors)

  13. Application of a radon model to explain indoor radon levels in a Swedish house

    International Nuclear Information System (INIS)

    Font, LL.; Baixeras, C.; Joensson, G.; Enge, W.; Ghose, R.

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75±30 and 200±80 Bq m -3 . Results of the model adaptation to the house indicate that soil constitutes the most relevant radon source in both parts of the house. The radon concentration values predicted by the model indoors fall into the same range as the experimental results

  14. CONTRIBUTION OF RADON FLOWS AND RADON SOURCES TO THE RADON CONCENTRATION IN A DWELLING

    NARCIS (Netherlands)

    DEMEIJER, RJ; STOOP, P; PUT, LW

    1992-01-01

    In this paper a model is presented for analysis of the radon concentrations in a compartment in terms of contributions from transport by flows of air between compartments and from radon sources in the compartment. Measurements were made to study the effect of increased natural ventilation of the

  15. Evidence of soil radon as tracer of magma uprising in Mt. Etna

    International Nuclear Information System (INIS)

    Morelli, D.; Martino, S. Di; Imme, G.; La Delfa, S.; Lo Nigro, S.; Patane, G.

    2006-01-01

    Soil radon has been monitored at one fixed site located in the northeastern flank of Mt. Etna, high-risk volcano in Sicily. The aim of this study was the evaluation of a possible link between magma uprising and soil radon concentration. Continuous radon measurements were performed since July 2001. Comparison between the in-soil radon trend and the acquired meteorological series (Temperature, Humidity and Pressure) seems to confirm a general seasonal correlation; nevertheless some anomalies suggest a possible dependence of the radon concentration on volcanic dynamics, as confirmed by the volcanic tremor and strain-release analysis

  16. Radon and its decay products in housing

    International Nuclear Information System (INIS)

    Swedjemark, G.A.

    1985-01-01

    Methods have been worked out for evaluation of the uncertainties due to temporal variations in the annual averages for the concentrations of radon-222 (radon) and radon daughters (RnD) indoors. These methods have been applied to the results from long-term measurements of radon in a few houses. The possible use of correction factors in order to get a more adequate annual average have also been studied and some examples have been given. On the basis of country-wide investigations carried out during 1955-56 and during 1972-75 averages of the radon concentrations in housing existing in 1950 and 1975 were calculated six years ago to be 29 and 71 Bq m -3 respectively. A new country-wide investigation with the aim of obtaining values representative for the country was carried out during 1980-82. On the basis of these results a new calculation was made of the concentrations in dwelllings existing in 1975 to 101 Bq m -3 and also for the 1980 housing stock to 98 Bq m -3 . These results are discussed and the collective dose equivalents in the Swedish population have been calculated. (author)

  17. Radon and radon daughter monitoring (including thoron daughter monitoring)

    International Nuclear Information System (INIS)

    Leach, V.A.; Grealy, G.; Gan, W.

    1982-01-01

    Radon/radon daughter and thoron daughter measurement techniques are outlined. The necessary precautions and critical assessments of each method are also presented with a view to providing a better understanding of the various measurement methods

  18. Uranium prospecting through radon detection; La prospection de l'uranium par le radon

    Energy Technology Data Exchange (ETDEWEB)

    Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    Prospecting rests on the determination of the concentration of ground air in radon. Radon diffusing from deep uranium bearing layers is detected in upper ground layers. (author) [French] La prospection est basee sur l'etude de la concentration en radon dans l'air du sol. Dans les terrains superficiels, on decele le radon qui diffuse a partir des couches profondes uraniferes. (auteur)

  19. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. If the subject moved to an environment with a lower radon concentration from an environment with a higher level of radon, the result would be an exhalation of radon, and the initial exhalation rate of radon should depend of the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. The author reports a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. 8 figures.

  20. Measurement of exhalation rate of radon and radon concentration in air using open vial method

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi.

    1991-01-01

    It was recognized that more than half of total exposure dose on human subject is caused by radon and its decay products which originate from naturally occurring radioactive substances (1988 UNSCEAR). Since then the exhalation of radon from the ground surface has received increasing attention. The authors have developed a new method for the determination of radon in natural water using toluene extraction of radon and applying a liquid scintillation counter of an integral counting technique which is able to get the absolute counting of radon. During these studies, the authors found out that when a counting vial containing of Liquid scintillator (LS)-toluene solution, without a lid, is exposed to the atmosphere for a while, dissolution of radon clearly occurs due to high solubility of radon into toluene layer. To extend this finding for the determination of radon in the atmosphere, the authors devised a new method to actively collect the atmosphere containing radon in a glass bottle by discharging a definite amount of water in it, which is named as open-vial dynamic method. The radon concentration can be easily calculated after the necessary corrections such as the partition coefficient and others. Applying proposed method to measure the radon exhalation rate from the ground surface and radon concentration in air of the dwelling environment, radioactive mineral spring zone and various geological formation such as granitic or sedimentary rocks. (author)

  1. The CEC radon research programme

    International Nuclear Information System (INIS)

    Olast, M.

    1990-01-01

    Following a council decision of 20 June 1989, a CEC research and training programme in the field of radiation protection has been adopted for the period 1990-1991. The european research programme is divided into three main areas, one being 'Risks and Management of Radiation Exposure': this includes a section on 'Exposure to natural radioactivity and evaluation of parameters influencing these risks'. The importance given to this field led to an impressive number of research proposals. The proposals accepted are grouped in three large multinational contracts covering radon exposure, and in one multinational contract dealing with environmental radon epidemiology. (author)

  2. Risks from radon

    International Nuclear Information System (INIS)

    Doll, Richard

    1992-01-01

    The best estimate of risk to which everyone is exposed from natural radon in buildings is now obtained by extrapolation from observations on men exposed to radon in mines. The relationship between dose and effect derived by the US National Research Council implies that about 6% of the current life-time risk of developing the disease in the UK is attributable to radon, but for residents of some houses it will be much greater. This estimate is dependent on many assumptions, some of which are certainly wrong, and reliable estimates can be obtained only by direct observations on people living in different houses. It is possible that radon may also cause some risk of other cancers, notably leukaemia, but such risks, if real, are certainly small. Studies in progress should provide reliable estimates of all radon induced risks within a few years. (author)

  3. Radon: Detection and treatment

    International Nuclear Information System (INIS)

    Loken, S.; Loken, T.

    1989-01-01

    Within the last few years, natural radon exposure in non-industrial settings, primarily homes, has become a health concern. Research has demonstrated that many homes throughout the United States have radon concentrations much higher than the legal federal limits set for miners. Thousands of unsuspecting people are being exposed to high levels of radiation. It is estimated that up to 15 percent of lung cancers are caused from radon. This is a significant health risk. With basic knowledge of the current information on radon, a primary health care provider can address patients' radon concerns and make appropriate referrals

  4. Radon-removal techniques for small community public water supplies

    International Nuclear Information System (INIS)

    Kinner, N.E.; Malley, J.P.; Clement, J.A.; Quern, P.A.; Schell, G.S.

    1990-08-01

    The report presents the results of an evaluation, performed by the University of New Hampshire--Environmental Research Group (ERG), of radon removal in small community water supplies using full-scale granular activated carbon adsorption, diffused bubble aeration and packed tower aeration. Various low technology alternatives, such as loss in a distribution system and addition of coarse bubble aeration to a pilot-scale atmospheric storage tank were also evaluated. The report discusses each of the treatment alternatives with respect to their radon removal efficiency, potential problems (i.e., waste disposal, radiation exposure and intermedia pollution), and economics in small community applications. In addition, several sampling methods, storage times, scintillation cocktails and extraction procedures currently used in the liquid scintillation technique for analysis of radon in water were compared

  5. The influence of thoron on measurement results of radon exhalation rate

    CERN Document Server

    Xiao De Tao; Ling Qiu; Leung, J K C

    2002-01-01

    Because of thoron exhalation, the measurement results of radon exhalation rate using a local still method is usually larger than the true value of radon flux rate of the monitored material surface. The influence of sup 2 sup 1 sup 6 Po(ThA) on radon exhalation rate can be eliminated for sensitive radon monitors. Theoretical evaluations of the influence of sup 2 sup 1 sup 2 Bi(ThC) and sup 2 sup 1 sup 2 Po(ThC')on radon exhalation rate are carried out in a sampler with diameter of 188 mm, and height of 125 mm, and supplied electrostatic field inside (generated by high voltage and electret) under following conditions: the sampling time are 1, 2, 3 h, respectively, thoron exhalation rate is 100 times of radon's. The calculation results indicate that the measurement results of radon flux rate are possibly 35.5% larger than true value due to the influence of thoron for fast and multifunctional radon monitors with electret, high voltage, respectively and using CR-39 SSNTD as detector, but this influence is negligib...

  6. Managing Radon in Schools

    Science.gov (United States)

    EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.

  7. Radon in workplaces

    International Nuclear Information System (INIS)

    Gooding, Tracy

    1995-01-01

    The naturally occurring radioactive gas radon has been found at excessive levels in many workplaces other than mines throughout the country. Prolonged exposure to radon and its decay products increases the risk of developing lung cancer, and controls to protect employees from excessive exposure are included in the Ionising Radiations Regulations 1985. The control of occupational exposure to radon is discussed here. (author)

  8. Radon and thoron emanation from various marble materials: impact on the workers

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Amghar, A.

    2005-01-01

    Uranium ( 238 U) and thorium ( 232 Th) concentrations were measured inside different pulverized marble material samples by using a method based on determining detection efficiencies of the CR-39 and LR-115 II solid state nuclear track detectors for the emitted alpha particles. Radon ( 222 Rn) and thoron ( 220 Rn) alpha-activities per unit volume were evaluated inside and outside the marble samples studied. Radon emanation coefficient was determined for the considered marble samples. Alpha- and beta-activities per unit volume of air due to radon, thoron and their progenies were measured in the atmosphere of a marble factory. Equilibrium factors between radon and its progeny and thoron and its decay products were evaluated in the air of the studied marble factory. The committed equivalent doses due to short-lived radon decay products were determined in different regions of the respiratory tract of workers in the considered marble factory

  9. Radon levels in drinking water of Fatehabad district of Haryana, India

    International Nuclear Information System (INIS)

    Duggal, Vikas; Sharma, Samriti; Mehra, Rohit

    2017-01-01

    Radon concentrations were measured in 59 groundwater samples collected from Fatehabad district of Haryana, India. The measurements were performed by RAD7 an electronic radon detector manufactured by Durridge Company Inc. The measured radon concentration ranged from 1.4 to 22.6 Bq l −1 . 14% of the groundwater samples were above the United States Environmental Protection Agency recommended value for radon in water. The annual effective dose for ingestion and inhalation was also evaluated in this research. The total annual effective dose due to ingestion and inhalation of radon in drinking water varied from 14.1 to 221.8 µSv y −1 . - Highlights: • We report the radon concentration in 59 groundwater samples from Haryana. • The water samples were characterized by RAD7 radon detector. • A 14% of the groundwater samples were above the USEPA recommended value. • Total annual effective dose from 12 locations was above EU Council recommendations.

  10. A Realistic Human Exposure Assessment of Indoor Radon released from Groundwater

    International Nuclear Information System (INIS)

    Yu, Dong Han; Han, Moon Hee

    2002-01-01

    The work presents a realistic human exposure assessment of indoor radon released from groundwater in a house. At first, a two-compartment model is developed to describe the generation and transfer of radon in indoor air from groundwater. The model is used to estimate radon concentrations profile of indoor air in a house using by showering, washing clothes, and flushing toilets. Then, the study performs an uncertainty analysis of model input parameters to quantify the uncertainty in radon concentration profile. In order to estimate a daily internal dose of a specific tissue group in an adult through the inhalation of such indoor radon, a PBPK(Physiologically-Based Pharmaco-Kinetic) model is developed. Combining indoor radon profile and PBPK model is used to a realistic human assessment for such exposure. The results obtained from this study would be used to the evaluation of human risk by inhalation associated with the indoor radon released from groundwater

  11. Monitoring of radon variation in both ground water and soil gas along Al-Ghab fault from 15 February to 23 June 1992

    International Nuclear Information System (INIS)

    Al-Hilal, M..; Al-Hent, R.

    1992-11-01

    The purpose of this report is to check the possibility of using radon monitoring technique which has been established as an additional aid for earthquake prediction elsewhere in the world, and to indicate whether radon measurements will frequently be useful in allowing the prediction of earthquakes along the seismically active Al-Ghab fault, in the western side of Syria. A network of ten sampling stations were setup along Al-Ghab fault segment for monitoring radon variations in both groundwater and soil gas. Sampling frequency was about once every three weeks. The overall results of this scientific study suggest the possibility of employing radon technique as a fairly good precursor in the Syrian earthquake prediction programme. To achieve this, however, a continuous monitoring of radon changes is required in groundwater and soil gas as well as other environmental variable especially air temperature, barometric pressure and wind velocity. Suitable grid patterns over the major seismic zones in Syria are necessary for obtaining the most reliable radon data. The establishment of seismic network in the region is extremely important for correlating radon data with the seismic activity records. (author). 4 refs., 7 figs., 3 tabs

  12. Radon and radon daughter measurements at and near the former Middlesex Sampling Plant, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    Haywood, F.F.; Perdue, P.T.; Christian, D.J.; Leggett, R.W.; Dickson, H.W.; Myrick, T.E.

    1980-03-01

    The results of the radon and radon daughter measurements made to date (1978) at the Middlesex Sampling Plant in Middlesex, New Jersey, are presented in this report. These measurements were one portion of a more comprehensive radiological survey conducted at this site and the surrounding area from 1976 to 1978. The surveyed property served as a uranium ore sampling plant during the 1940's and early 1950's and as a result contains elevated levels of surface an subsurface contamination. On-site indoor radon daughter and radon concentrations exceeded both the US Surgeon General Guidelines and the Nuclear Regulatory Commission's maximum permissible concentration limits for radon (10 CFR Part 20) in all structures surveyed. Off-site structures showed concentrations of radon and radon daughters at or only slightly above background levels, except for one site where the radon levels were found to be above the 10 CFR Part 20 guidelines. Outdoor radon ad radon daughter concentrations, measured both on and off the site, were well below the guidelines, and the data give no indication of significant radon transport from the site

  13. Geographical associations between radon and cancer: is domestic radon level a marker of socioeconomic status?

    International Nuclear Information System (INIS)

    Wolff, S.P.; Stern, G.

    1991-01-01

    Previous studies showing a geographical association between radon and various cancers, particularly the leukaemias and lymphomas, appear to be confounded by the role of radon levels as a surrogate for socioeconomic status. Higher socioeconomic status (at least at the UK county level) is correlated with higher levels of domestic radon. Controlling for the relationship between socioeconomic status and radon removes the correlation between radon exposure and lymphoproliferative disease. Reported associations between radon and lymphoproliferative disease (and possibly other cancers) may be secondary to socioeconomic variables. (author)

  14. Inverse method for determining radon diffusion coefficient and free radon production rate of fragmented uranium ore

    International Nuclear Information System (INIS)

    Ye, Yong-jun; Wang, Li-heng; Ding, De-xin; Zhao, Ya-li; Fan, Nan-bin

    2014-01-01

    The radon diffusion coefficient and the free radon production rate are important parameters for describing radon migration in the fragmented uranium ore. In order to determine the two parameters, the pure diffusion migration equation for radon was firstly established and its analytic solution with the two parameters to be determined was derived. Then, a self manufactured experimental column was used to simulate the pure diffusion of the radon, the improved scintillation cell method was used to measure the pore radon concentrations at different depths of the column loaded with the fragmented uranium ore, and the nonlinear least square algorithm was used to inversely determine the radon diffusion coefficient and the free radon production rate. Finally, the solution with the two inversely determined parameters was used to predict the pore radon concentrations at some depths of the column, and the predicted results were compared with the measured results. The results show that the predicted results are in good agreement with the measured results and the numerical inverse method is applicable to the determination of the radon diffusion coefficient and the free radon production rate for the fragmented uranium ore. - Highlights: • Inverse method for determining two transport parameters of radon is proposed. • A self-made experimental apparatus is used to simulate radon diffusion process. • Sampling volume and position for measuring radon concentration are optimized. • The inverse results of an experimental sample are verified

  15. Is environmental radon gas associated with the incidence of neurodegenerative conditions? A retrospective study of multiple sclerosis in radon affected areas in England and Wales

    International Nuclear Information System (INIS)

    Groves-Kirkby, Christopher J.; Denman, Antony R.; Campbell, Jackie; Crockett, Robin G.M.; Phillips, Paul S.; Rogers, Stephen

    2016-01-01

    To test whether an association exists between radon gas concentration in the home and increased multiple sclerosis (MS) incidence, a retrospective study was undertaken of MS incidence in known areas of raised domestic radon concentration in England and Wales, using The Health Improvement Network (THIN) clinical research database. The study population comprised 20,140,498 person-years of clinical monitoring (males: 10,056,628: 49.93%; females: 10,083,870: 50.07%), representing a mean annual population of 2.5 million individuals. To allow for the possible latency of MS initiation following exposure, data extraction was limited to patients with at least five years registration history with the same GP practice before first diagnosis. Patient records were allocated to one of nine radon concentration bands depending on the average radon level in their postcode sector. MS incidence was analysed by searching for patients with first MS diagnosis over the eight calendar years 2005–2012 inclusive. 1512 new MS cases were diagnosed, 1070 females, 442 males, equivalent to raw incidence rates of 7.51, 10.61 and 4.40 per 10 5 person-years respectively, comparable to previously reported results. Of these new cases, 115 could be allocated to one of the radon bands representing high radon areas. Standardising to the UK 2010 population, excess relative risk (ERR) figures for MS were calculated for each radon band. Linear regression of ERR against mean band radon concentration shows a positive gradient of 0.22 per 100 Bq·m −3 (R 2  = 0.25, p = 0.0961) when forced through the origin to represent a linear-no-threshold response. The null hypothesis falls inside the 95% confidence interval for the linear fit and therefore this fit is not statistically significant. We conclude that, despite THIN sampling around 5% of the population, insufficient data was available to confirm or refute the hypothesised association between MS incidence and radon concentration. - Highlights:

  16. Surface-deposition and distribution of the radon-decay products indoors

    International Nuclear Information System (INIS)

    Espinosa, G.; Tommasino, L.

    2015-01-01

    The exposure to radon-decay products is of great concern both in dwellings and workplaces. The model to estimate the lung dose refers to the deposition mechanisms and particle sizes. Unfortunately, most of the dose data available are based on the measurement of radon concentration and the concentration of radon decay products. These combined measurements are widely used in spite of the fact that accurate dose assessments require information on the particle deposition mechanisms and the spatial distribution of radon decay products indoors. Most of the airborne particles and/or radon decay products are deposited onto indoor surfaces, which deposition makes the radon decay products unavailable for inhalation. These deposition processes, if properly known, could be successfully exploited to reduce the exposure to radon decay products. In spite of the importance of the surface deposition of the radon decay products, both for the correct evaluation of the dose and for reducing the exposure; little or no efforts have been made to investigate these deposition processes. Recently, two parallel investigations have been carried out in Rome and at Universidad Nacional Autónoma de México (UNAM) in Mexico City respectively, which address the issue of the surface-deposited radon decay products. Even though these investigations have been carried independently, they complement one another. It is with these considerations in mind that it was decided to report both investigations in the same paper. - Highlights: • Distribution of Radon and Thoron decay indoor products. • Indoor radon measurements complexity. • Short and long term measurements of surface deposit of Radon and Thoron decay products. • Microclimate controlled conditions room. • Nuclear Tracks Detectors

  17. Studies of Radon and Radon Progeny in Air Conditioned Rooms in Hospitals

    International Nuclear Information System (INIS)

    Marley, F.; Denman, A.R.; Phillips, P.S.

    1998-01-01

    A series of continuous real-time radon and radon progeny measurements together with passive etched track detector measurements were performed in hospital premises during 1996. In one small room, detailed measurements over several weeks showed that both the radon concentration and the Equilibrium Factor depended on the intermittent operation of a filtered positive pressure displacement air-conditioning system, which was designed to conform to operating theatre standards. The average radon level measured while the air-conditioning was off was almost four times higher than that recorded whilst it was on. The progeny level was over five times higher than that whilst it was on. Thus, the Equilibrium Factor (F), was significantly lower when the air-conditioning was on. Measurements in similar rooms in two hospitals, confirmed that the reduction in radon level was a general finding. Thus staff working in such environments receive significantly lower radiation dose from radon than staff working in nearby normally ventilated rooms. (author)

  18. A comparison of contemporary and retrospective radon gas measurements in high radon dwellings in Ireland

    International Nuclear Information System (INIS)

    Kelleher, K.; McLaughlin, J.P.; Fenton, D.; Colgan, P.A.

    2006-01-01

    Little correlations has been found between contemporary radon gas measurements made in the past and retrospective radon gas measurements in Irish dwellings. This would suggest that these two techniques would result in two significantly different cumulative radon exposure estimates. Contemporary radon gas measurements made a few years apart in the same room of a dwelling were found to be significantly different. None of these differences could be explained by known changes to the rooms themselves., such ventilation or structural alterations to the room. This highlights the limitations of the contemporary radon gas measurements as a surrogate measurement for use in residential radon epidemiology. The contemporary radon gas measurements made by the Radiological Protection Institute of Ireland (R.P.I.I.) and University College of Dublin (U.C.D.) do not cover the same exposure period as the retrospective estimates and so the accuracy of the retrospective measurements cannot be demonstrated. A weak correlation can be seen between the retrospective radon gas estimates and a combination of the two contemporary radon gas estimates. It is not unreasonable to expect improvement in the correlation if further contemporary radon gas measurements were made in these rooms. (N.C.)

  19. Radon in workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.; Annanmaeki, M.; Oksanen, E.

    2000-01-01

    The EU Member States have to implement the new Basic Safety Standards Directive (BSS) by May 2000. The Title VII of the Directive applies in particular to radon in workplaces. The Member States are required to identify workplaces which may be of concern, to set up appropriate means for monitoring radon exposures in the identified workplaces and, as necessary, to apply all or part of the system of radiological protection for practices or interventions. The BSS provisions on natural radiation are based on the ICRP 1990 recommendations. These recommendations were considered in the Finnish radiation legislation already in 1992, which resulted in establishing controls on radon in all types of workplaces. In this paper issues are discussed on the practical implementation of the BSS concerning occupational exposures to radon basing on the Finnish experiences in monitoring radon in workplaces during the past seven years. (orig.) [de

  20. Radon Research Program, FY 1992

    International Nuclear Information System (INIS)

    1993-04-01

    The United States Department of Energy, Office of Health and Environmental Research (DOE/OHER) is the principal federal agency conducting basic research related to indoor radon. The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. There still remains a significant number of uncertainties in the currently available knowledge that is used to estimate lung cancer risk from exposure to environmental levels of radon and its progeny. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny and to identify and understand biological mechanisms of lung cancer development and required copollutants at low levels of exposure. Information useful in radon control strategies is also provided by the basic science undertaken in this program

  1. Modeling of indoor radon

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    1990-01-01

    This paper reports on models for radon, which are developed not only to describe the behavior of radon and daughters since the moment that radon is created in natural sources by the alpha decay of 226 Ra up to the point that doses to humans are estimated based on the inhalation of radon and its progeny. The objective of a model should be determinant in defining the model structure and boundaries. Modeling indoors radon is particularly useful when the 226 Ra concentration in building materials and soils can be known before a house will be built with such 226 Ra bearing materials and over 226 Ra rich soils. The reported concentrations of 226 Ra in building materials range from 0.3 Bq · kg -1 in wood to about 2.6 x 10 3 Bq · kg -1 in aerated concrete based on alum shale. 30 In addition, when a house is built on a soil containing a high 226 Ra concentration, radon exhalation from the soil contributes to increase radon concentration indoors. The reported radon exhalation from soils range from 3.4 Bq · m -2 · s -1 in latosolic soil from Osaka, Japan to about 53 mBq · m -2 · s -1 in chernozemic soil from Illinois

  2. Scopingsreport Radon

    NARCIS (Netherlands)

    Blaauboer RO; Vaas LH; Hesse JM; Slooff W

    1989-01-01

    Dit scopingsrapport vormt een onderdeel van de voorbereiding tot het opstellen van het basisdocument radon. Het doel van dit rapport is het algemene kennisniveau van de deelnemers aan de scopingsbijeenkomst aangaande radon op eenzelfde peil te brengen en discussie- en beslispunten inzake de

  3. Radon in dwellings

    International Nuclear Information System (INIS)

    Erikson, B.E.; Boman, C.A.; Nyblom, L.; Swedjemark, G.A.

    1980-06-01

    The report presents the function of the ventilation by natural draught in three-storey houses. In some cases also the measurement of gamma radiation, radon and radon daughters was made. The investigation took place in Uppsala. The houses were built of light weight concrete made of alum-shale. The measurements showed that the contents of radon daughters were far below the provisional limits. (G.B.)

  4. Comparison of field-measured radon diffusion coefficients with laboratory-measured coefficients

    International Nuclear Information System (INIS)

    Lepel, E.A.; Silker, W.B.; Thomas, V.W.; Kalkwarf, D.R.

    1983-04-01

    Experiments were conducted to compare radon diffusion coefficients determined for 0.1-m depths of soils by a steady-state method in the laboratory and diffusion coefficients evaluated from radon fluxes through several-fold greater depths of the same soils covering uranium-mill tailings. The coefficients referred to diffusion in the total pore volume of the soils and are equivalent to values for the quantity, D/P, in the Generic Environmental Impact Statement on Uranium Milling prepared by the US Nuclear Regulatory Commission. Two soils were tested: a well-graded sand and an inorganic clay of low plasticity. For the flux evaluations, radon was collected by adsorption on charcoal following passive diffusion from the soil surface and also from air recirculating through an aluminum tent over the soil surface. An analysis of variance in the flux evaluations showed no significant difference between these two collection methods. Radon diffusion coefficients evaluated from field data were statistically indistinguishable, at the 95% confidence level, from those measured in the laboratory; however, the low precision of the field data prevented a sensitive validation of the laboratory measurements. From the field data, the coefficients were calculated to be 0.03 +- 0.03 cm 2 /s for the sand cover and 0.0036 +- 0.0004 cm 2 /s for the clay cover. The low precision in the coefficients evaluated from field data was attributed to high variation in radon flux with time and surface location at the field site

  5. Application of a radon model to explain indoor radon levels in a Swedish house

    CERN Document Server

    Font, L; Jönsson, G; Enge, W; Ghose, R

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75+-30 and 200+-80 Bq m sup - sup 3...

  6. Comparing summer and winter indoor radon and radon daughters activity in Campinas, Brazil

    International Nuclear Information System (INIS)

    Guedes, O.S.; Hadler, N.J.C.; Iunes, P.J.; Neman, R.S.; Souza, W.F.; Tello, S.C.A.; Paulo, S.R.

    2002-01-01

    We developed a technique - based on alpha particle track detection using CR-39 - where the activity originated from indoor radon can be potentially separated into three fraction: (i) radon in the air, (ii) radon daughters (RD), 218 Po and 214 Po, in the air and (iii) RD plated-out on the detector surface during exposure. In this work only a partial separation was carried out, then our results are limited to radon plus RD in the air and RD attached to detector surface. These activities can be separated if size and gray level of the round tracks are measured using an automatic optical microscopy system.Our group carried out an indoor radon and radon daughters (RD) survey in Campinas made up by a summer (November, 96 to May, 97) and a winter (May, 97 to November, 97) exposure, where the detectors were placed in the same rooms of the same dwellings (approximately 100) in both cases. Comparing winter and summer alpha activity for the detectors analyzed up to now, approximately 45 dwellings, we observed that: i) it seems that the source of radon is the material (brick and concrete mainly) making up walls, floor and ceiling of the dwellings, ii) there is no clear relationship between intensity of aeration and the activities measured in this work, and iii) the average ratio between winter and summer activity in the air (radon plus RD) is approximately equal to similar ratios observed in other countries, but for radon only. (author)

  7. Application of the can technique and radon gas analyzer for radon exhalation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I.; Musazay, M.S.; Abu-Jarad, F

    2003-12-01

    A passive 'can technique' and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bq m{sup -2} h{sup -1} with an average of 1.35{+-}1.40 Bq m{sup -2} h{sup -1}. The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  8. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    International Nuclear Information System (INIS)

    Guedes, S.; Hadler, J.C.N.; Iunes, P.J.; Navia, L.M.S.; Neman, R.S.; Paulo, S.R.; Rodrigues, V.C.; Souza, W.F.; Tello, C.A.S.; Zuniga, A.

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied

  9. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    CERN Document Server

    Guedes, S; Iunes, P J; Navia, L M S; Neman, R S; Paulo, S R; Rodrigues, V C; Souza, W F; Tello, C A S; Zúñiga, A G

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied.

  10. Radon as a hydrological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Komae, Takami [National Research Inst. of Agricultural Engineering, Tsukuba, Ibaraki (Japan)

    1997-02-01

    The radon concentration in water is measured by a liquid scintillation method. After the radioactive equilibrium between radon and the daughter nuclides was attained, the radon concentration was determined by the liquid scintillation analyzer. {alpha}-ray from radon, then two {beta}- and two {alpha}-ray from the daughter nuclei group were released, so that 500% of the apparent counting efficiency was obtained. The detector limit is about 0.03 Bq/l, the low value, which corresponds to about 5.4x10{sup -15} ppm. By determining the radon concentration in groundwater, behavior of radon in hydrological process, the groundwater exchange caused by pumping and exchange between river water and groundwater were investigated. The water circulation analysis by means of radon indicator in the environment was shown. By using the large difference of radon concentration between in river water and in groundwater, arrival of injected water to the sampling point of groundwater was detected. (S.Y.)

  11. Control of radon in Finnish workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.

    2002-01-01

    Natural radiation in Finland is regulated in the Finnish Radiation Act from 1992. Occupational exposure to natural radiation is regulated by an amendment of the Radiation Decree in 1998. The most important issues in Finland are radon in workplaces, radioactivity in drinking water and in building materials, and mining and industrial processes. Radon levels in mines have been measured regularly since 1972. Finland has an action level for radon in workplaces of 400 Bq/m 3 . Radon prone areas have been identified primarily from measurements of radon in dwellings. Radon measurements are compulsory in workplaces in radon prone areas unless it can be shown by other means that radon levels are low. A programme focusing on radon in workplaces was initiated in 1992. To date, radon measurements have been carried out in 10,000 workplaces and remedial actions have been taken in 200 of these. The average reduction in radon concentration in remediated buildings is about 1,500 Bq/m 3 . Identification of NORM industries is based on the radionuclide content of the materials used (>1.4 Bq/g U and >0.4 Bq/g Th). The occupational exposure should not exceed 1 mSv/y (excluding radon)

  12. Radon mitigation in schools

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Saum, D.W.

    1990-01-01

    This article reports on radon mitigation in school buildings. Subslab depressurization (SSD) has been the most successful and widely used radon reduction method in houses. Thus far, it has also substantially reduced radon levels in a number of schools. Schools often have interior footings or thickened slabs that may create barriers for subslab air flow if a SSD system is the mitigation option. Review of foundation plans and subslab air flow testing will help to determine the presence and effect of such barriers. HVAC systems in schools vary considerable and tend to have a greater influence on pressure differentials (and consequently radon levels) than do heating and air-conditioning systems encountered in the radon mitigation of houses. As part of any radon mitigation method, ASHRAE Standard 62-1989 should be consulted to determine if the installed HVAC system is designed and operated to achieve minimum ventilation standards for indoor air quality

  13. Radon risk in the house; Il rischio radon nelle abitazioni

    Energy Technology Data Exchange (ETDEWEB)

    Bressa, G. [Padua Univ., Padua (Italy). Dipt. di Farmacologia e Anestesiologia, Lab. di Tossicologia

    2001-04-01

    Radon was discovered in 1900, but its potential dangerousness for man was fully understood only in 1950. Being a radioactive natural gas - and therefore particularly dangerous - radon results from the long decay chain of radionuclides, such as thorium and radium. Some igneous rocks (granite, tufa and lava) as well as coal are considered to be the main sources of this radionuclide. A number of epidemiologic studies have shown the carcinogenicity of this element, particularly among miners and workers subjected to high level exposure in confined spaces such as basements, garages, cellars, etc. There are, however, some techniques to remove radon in order to reduce exposure to minimum values. [Italian] Il radon fu scoperto nel 1900, ma solo nel 1950 si comprese la sua potenziale pericolosita' per l'uomo. Il radon e' particolarmente pericoloso essendo un gas naturale radioattivo. Esso proviene dalla lunga catena di decadimento di radionuclidi come il torio e di radio. Sorgenti di tale radionuclide sono da considerarsi principalmente alcune rocce ignee (graniti, tufi e lave) e il carbone. Diversi studi epidemiologici hanno evidenziato la cancerogenicita' di tale elemento, specie tra i minatori e soggetti esposti ad alti livelli in ambienti confinati quali scantinati, garage sotterranei, ecc.. Esistono comunque tecniche di intervento per la rimozione del gas radon in modo tale da ridurre l'esposizione a valori minimi.

  14. Radon concentration: A tool for assessing the fracture network at ...

    African Journals Online (AJOL)

    drinie

    2003-01-01

    Jan 1, 2003 ... This work has positive implications for the location of groundwater resources in fractured-rock aquifers such as in South Africa, where most ... tool in groundwater exploration in South Africa, where the passive Radon Gas Monitor ..... rainfall infiltration, the main infiltration area can be identified;. • The method ...

  15. Predictors of Indoor Radon Concentrations in Pennsylvania, 1989–2013

    Science.gov (United States)

    Casey, Joan A.; Ogburn, Elizabeth L.; Rasmussen, Sara G.; Irving, Jennifer K.; Pollak, Jonathan; Locke, Paul A.

    2015-01-01

    Background Radon is the second-leading cause of lung cancer worldwide. Most indoor exposure occurs by diffusion of soil gas. Radon is also found in well water, natural gas, and ambient air. Pennsylvania has high indoor radon concentrations; buildings are often tested during real estate transactions, with results reported to the Department of Environmental Protection (PADEP). Objectives We evaluated predictors of indoor radon concentrations. Methods Using first-floor and basement indoor radon results reported to the PADEP between 1987 and 2013, we evaluated associations of radon concentrations (natural log transformed) with geology, water source, building characteristics, season, weather, community socioeconomic status, community type, and unconventional natural gas development measures based on drilled and producing wells. Results Primary analysis included 866,735 first measurements by building, with the large majority from homes. The geologic rock layer on which the building sat was strongly associated with radon concentration (e.g., Axemann Formation, median = 365 Bq/m3, IQR = 167–679 vs. Stockton Formation, median = 93 Bq/m3, IQR = 52–178). In adjusted analysis, buildings using well water had 21% higher concentrations (β = 0.191, 95% CI: 0.184, 0.198). Buildings in cities (vs. townships) had lower concentrations (β = –0.323, 95% CI: –0.333, –0.314). When we included multiple tests per building, concentrations declined with repeated measurements over time. Between 2005 and 2013, 7,469 unconventional wells were drilled in Pennsylvania. Basement radon concentrations fluctuated between 1987 and 2003, but began an upward trend from 2004 to 2012 in all county categories (p Pennsylvania, 1989–2013. Environ Health Perspect 123:1130–1137; http://dx.doi.org/10.1289/ehp.1409014 PMID:25856050

  16. Soil and gas and radon entry potentials for substructure surfaces

    International Nuclear Information System (INIS)

    Harrison, J.; Sextro, R.G.

    1990-01-01

    This paper reports on measurement techniques and parameters that describe the potential for areas of a building substructure to have high soil gas and radon entry rates which have been developed. Flows and pressures measured at test holes in substructure surfaces while the substructure was intentionally depressurized were used in a highly simplified electrical circuit to model the substructure/soil network. Data from four New Jersey houses indicate that the soil was a factor of two to six times more resistant to soil gas flow than substructure surfaces, concrete slab floors, including perimeter gaps, cracks, and other penetrations, were approximately five times more resistant to soil gas movement than hollow block walls, and radon entry potentials were highest for slab floors. These indices of entry potential may be useful for characterizing the relative leakiness of below-grade substructure surfaces and for determining the selection and placement of radon control systems

  17. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)

  18. Radon-daughter exposures in energy-efficient buildings

    International Nuclear Information System (INIS)

    Nero, A.V.; Berk, J.V.; Boegel, M.L.; Hollowell, C.D.; Ingersoll, J.G.; Nazaroff, W.W.

    1981-10-01

    A radon concentration of 1 pCi/1 (37 Bq/m 3 ) appears to lie in the range that is typical for air inside US residential buildings. Moreover, some US residences have concentrations higher than 1 pCi/1, sometimes by an order of magnitude, implying significant individual risk to occupants. For typical radon daughter equilibrium ratios, this concentration corresponds to a radon daughter exposure rate of 0.2 working level months (WLM) per year. This exposure rate may account for a significant lung cancer incidence if data on lung cancers per unit exposure in miners are applicable to such low exposures. Reductions in air exchange rates may rise the typical exposure rate and even increase it to unacceptable levels in some cases. Measures that reduce energy use by reducing natural infiltration or mechanical ventilation in new or retrofit buildings are therefore undergoing severe scrutiny. Lawrence Berkeley Laboratory has performed measurements in buildings specifically designed to use energy efficiently or utilize solar heating. In many of these buildings radon concentrations appear to arise primarily from soil underlying the buildings. Measures to control higher levels, e.g., by mechanical ventilation with heat recuperation, appear to be economical. However, to evaluate energy-saving programs adequately requires a much more comprehensive characterization of radon sources (for example, by geographical area) and a much fuller understanding of the dynamics of radon and its daughters indoors than now exist

  19. What did we learn from the Austrian radon project?

    International Nuclear Information System (INIS)

    Friedmann, H.

    2004-01-01

    Approximately 40000 measurements of indoor radon concentrations were performed in randomly selected homes during the Austrian Radon Project. These measurements were carried out by using long-term measuring devices (SSNTD and Electret detectors) and short-term charcoal detectors with liquid scintillation counting as the method of analysis. In addition to the equilibrium factor, soil gas measurements and quasi-continuous indoor measurements, parallel-measurements with different detector systems in randomly selected homes were also performed. Very different results were occasionally obtained for one and the same room at the same time. This was so not only when comparing the long-term and short-term measuring devices; actually, different long-term detector systems also often showed significant discrepancies in results, although all detector systems had been carefully calibrated and tested in laboratories. The essential conclusion was that during a longer exposure in randomly selected homes, the detectors may be moved, opened, or handled in other unfavourable ways which introduce additional uncertainties in the measuring results. The aim of the Austrian Radon Project was to estimate the radon risk for geographic areas (municipalities). This task is different from the evaluation of the mean radon concentration in a single home. Generally, while long-term measurements (a year or even longer) are necessary to get reliable results for a particular house, this is not so where only the mean indoor radon concentrations for an area are of interest. Observed indoor radon concentrations give information about the actual radon exposures of the inhabitants but not about the radon risk from the ground. The house type, the way the house is constructed, the storey where people live, and some living patterns (ventilation rate etc.) modify the geological risk significantly, although it is the geological situation that has to be primarily taken into account when planning and constructing

  20. The therapeutic use of radon; Radon als Heilmittel

    Energy Technology Data Exchange (ETDEWEB)

    Deetjen, P [Innsbruck Univ. (Austria). Inst. fuer Physiologie und Balneologie

    1995-09-01

    Spas with a somewhat elevated concentration of Radon{sup 222} (between 300 and 3000 Bq/l) are described to achieve good clinical results in the treatment of chronic rheumatic diseases. Recently a prospective randomized doubel-blind-study proved the pain reducing efficacy of Radon therapy in patients with cervical pain. Studies in experimental animal models have accumulated remarkable data in tissues and organs that provide a rationale to explain the observed effects of Radon therapy in patients. (orig.) [Deutsch] In verschiedenen europaeischen und asiatischen Laendern werden oft schon seit vielen Jahrhunderten Quellen als besonders heilkraeftig beschrieben, die eine etwas erhoehte Aktivitaet an Radon{sup 222} aufweisen (etwas zwischen 300 und 3000 Bq/l). Neuerdings liegt auch eine prospektive randomisierte Doppelblind-Studie vor, die den klinischen Nachweis der Schmerzlinderung durch eine Radonkur erbringt. In tierexperimentellen Untersuchungen wurden unter Radonexposition zahlreiche stimulierende Effekte auf Zellstoffwechsel, Immunabwehr, Abbau toxischer Radikale, DNA-Reparatur-Systeme oder Synthese von Mediatorsubstanzen gemessen, die rationale Ansaetze fuer das Verstaendnis der Wirkung einer Radonexposition im niedrigen Dosisbereich ergeben. (orig.)

  1. Radon and its measurement

    International Nuclear Information System (INIS)

    Penzo, Silvia

    2006-03-01

    The work reviews the topics concerning the problem of the indoor radon and its measurement. The initial stage deals with the general features of radon, from the historical remarks about its discovery to the formation mechanisms in the soil, then passing to describe the transport processes that lead the radon to enter into the buildings. The mean radon concentration distribution among the Italian regions is reported and compared with the situation in the other countries of the world. A particular importance is given to present the national law concerning the radioprotection from the natural sources of ionizing radiations; a paragraph is completely devoted to this argument and to discuss the differences between the Italian approach and the regulations applied in the Test of Europe for both workplaces and dwellings. Chapter 3 describes the different detectors and methods to measure the radon and its short mean live decay products concentrations, together with the operative procedures and guides provided by the Italian law and by the international bodies. As an example of typical radon passive measurement device. the new ENEA detector developed at the Institute of Radioprotection is presented and discussed. Appendix 1 is entirely devoted to discuss the main remedial actions for decreasing the radon indoor concentration both for old and new buildings; appendix 2 reports the main quantities related to radon and radioprotection [it

  2. Radon in public buildings

    International Nuclear Information System (INIS)

    Schulz, H.; Flesch, K.; Hermann, E.; Loebner, W.; Leissring, B.

    2009-01-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  3. Improved thomas formula for radon measurement

    International Nuclear Information System (INIS)

    Ji Changsong

    1991-06-01

    The FT 648 type portable absolute radon meter has been developed and the designing principle of this instrument is introduced. The absolute radon meter differs from relative radon meter. By using structure parameters, operating parameters and readout of this instrument, the radon content of measured gas is obtained directly without calibration in advance. Normally, the calibration is done by a standard radioactive gaseous source of which the radon concentration is known. The systematic error is removed by adding filter-efficiency Σ, α self-absorption correction β, energy spectrum correction S, geometric factor Ω of probe and gravity dropping correction factor G to the Thomas formula for radon measurement of two-filter method. The atmosphere radon content, which is given in hour-average, in Beijing area was measured by FT 648 type absolute radon meter. The measurement lasted continuously for several days and nights and a 'saddle shape' of radon content-time curve was observed. The day's average radon content was 8.5 Bq·m -3

  4. Technique and equipment for measuring volume activity of radon in the air of radon laboratories and clinics

    International Nuclear Information System (INIS)

    Vorob'ev, I.B.; Krivokhatskij, A.S.; Nekrasov, E.V.; Nikolaev, V.A.; Potapov, V.G.; Terent'ev, M.V.

    1990-01-01

    Usability of a new equipment-technique combination for measuring radon activity in the air of radon laboratories and balneological clinics is studied. The complex includes nitrate-cellulose detector, radon chamber, Aist, Istra type spark counters and technique of spark counting. The method sensitivity is 50 Bqxm 3 , the error is 30%. Usability and advisability of track method in radon laboratories and balneological clinics for simultaneous measurement in several points of integral volumetric radon activities are confirmred. The method permits to carry out rapid and accurate bulk investigations. The results of determining mean volumetric radon activity in the air in different points of radon laboratory and radon clinics are presented

  5. Radon in dwellings the national radon survey Cork and Kerry

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.

    1998-07-01

    This report presents the results of the third phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Cork and Kerry. The average radon concentrations for the houses measured in these counties were 76 Bq/m 3 and 70 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  6. Human Lung Cancer Risks from Radon – Part III - Evidence of Influence of Combined Bystander and Adaptive Response Effects on Radon Case-Control Studies - A Microdose Analysis

    Science.gov (United States)

    Leonard, Bobby E.; Thompson, Richard E.; Beecher, Georgia C.

    2012-01-01

    Since the publication of the BEIR VI (1999) report on health risks from radon, a significant amount of new data has been published showing various mechanisms that may affect the ultimate assessment of radon as a carcinogen, in particular the potentially deleterious Bystander Effect (BE) and the potentially beneficial Adaptive Response radio-protection (AR). The case-control radon lung cancer risk data of the pooled 13 European countries radon study (Darby et al 2005, 2006) and the 8 North American pooled study (Krewski et al 2005, 2006) have been evaluated. The large variation in the odds ratios of lung cancer from radon risk is reconciled, based on the large variation in geological and ecological conditions and variation in the degree of adaptive response radio-protection against the bystander effect induced lung damage. The analysis clearly shows Bystander Effect radon lung cancer induction and Adaptive Response reduction in lung cancer in some geographical regions. It is estimated that for radon levels up to about 400 Bq m−3 there is about a 30% probability that no human lung cancer risk from radon will be experienced and a 20% probability that the risk is below the zero-radon, endogenic spontaneous or perhaps even genetically inheritable lung cancer risk rate. The BEIR VI (1999) and EPA (2003) estimates of human lung cancer deaths from radon are most likely significantly excessive. The assumption of linearity of risk, by the Linear No-Threshold Model, with increasing radon exposure is invalid. PMID:22942874

  7. Radon programmes and health marketing.

    Science.gov (United States)

    Fojtikova, Ivana; Rovenska, Katerina

    2011-05-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed.

  8. Leukaemia risks and radon

    International Nuclear Information System (INIS)

    Wolff, S.P.

    1991-01-01

    A correlation has been established between domestic radon exposure and mutation in peripheral T lymphocytes. Some caution must be exercised, however, in interpreting this result as evidence that levels of domestically encountered radon are sufficient to cause leukaemogenic chromosomal alterations. Radon may simply be acting as a surrogate for some other mutagenic factor. Correlations with Local Authority statistics collected in the United Kingdom 1981 Census appear to show that lower domestic radon levels reflect relatively greater socioeconomic deprivation whereas higher levels reflect greater prosperity. The relative risk of lymphoproliferative disease correlates with the same factors that determine domestic radon levels at the county level. Putative relationships between domestic radon exposure and cancer thus need to be controlled for socioeconomic status and associated factors, at least at the county level. (The correlations may not apply to smaller areas.) Similarly, the causative factors underlying the relationships between higher regional socioeconomic status and leukaemia require closer examination. (author)

  9. The significance of radon in radioactive pollution of environment. Pt. 2. Radon effect on living organism

    International Nuclear Information System (INIS)

    Kossakowski, S.; Dziura, A.; Kossakowski, A.

    1998-01-01

    Authors review the history of radon monitoring. Epidemiological studies of lung cancer and its correlation to radon concentration in mines and buildings are described. The influence of radon on animals living in the buildings built from waste materials is described. Authors review plans concerning creation of radon monitoring system in Poland. The necessity of monitoring influence of radon on animals is described

  10. Preliminary results of NAPL contamination in a disused industry in the city of Sao Paulo, Brazil, by radon evaluation with CR-39 detectors

    International Nuclear Information System (INIS)

    Mateus, Crislene; Pecequilo, Brigitte Roxana Soreanu

    2015-01-01

    Contaminated sites by NAPL (Non-Aqueous Phase-Liquids) may lead to safety risks to human health and to ecosystems, restrictions to urban development and decrease of real estate value. This work used the radon gas as an indicator for the analysis of subsurface soil gas, once this noble gas presents good solubility in a wide range of NAPL, being partially retained in the NAPL contamination. Therefore, a decrease of the activity of radon in the contaminated soil gas can be expected, due to the high capacity of partitioning of radon in NAPL, which allows that the NAPL retain part of the radon previously available in the soil pores. The survey was carried out at a disused industry, contaminated by low volatile NAPL, located at east of Sao Paulo city, in March/2015. Radon was evaluated by passive detection methodology with CR-39 solid state nuclear track detectors (SSNTD). Radon concentrations for the eight monitoring stations at non-contaminated locations in March/2015 varied from 16.4 ± 1.2 kBq.m -3 to 55 ± 4 kBq.m -3 . For the two monitoring stations assumed as contaminated locations in March/2015, radon concentrations were 1.17 ± 0.08 kBq.m -3 and 4.2 ± 0.3 kBq.m -3 , diminished in a range from 92% to 98% when compared with the results for the non-contaminated areas. (author)

  11. Preliminary results of NAPL contamination in a disused industry in the city of Sao Paulo, Brazil, by radon evaluation with CR-39 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mateus, Crislene; Pecequilo, Brigitte Roxana Soreanu, E-mail: crislene@ipen.br, E-mail: brigitte@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Contaminated sites by NAPL (Non-Aqueous Phase-Liquids) may lead to safety risks to human health and to ecosystems, restrictions to urban development and decrease of real estate value. This work used the radon gas as an indicator for the analysis of subsurface soil gas, once this noble gas presents good solubility in a wide range of NAPL, being partially retained in the NAPL contamination. Therefore, a decrease of the activity of radon in the contaminated soil gas can be expected, due to the high capacity of partitioning of radon in NAPL, which allows that the NAPL retain part of the radon previously available in the soil pores. The survey was carried out at a disused industry, contaminated by low volatile NAPL, located at east of Sao Paulo city, in March/2015. Radon was evaluated by passive detection methodology with CR-39 solid state nuclear track detectors (SSNTD). Radon concentrations for the eight monitoring stations at non-contaminated locations in March/2015 varied from 16.4 ± 1.2 kBq.m{sup -3} to 55 ± 4 kBq.m{sup -3}. For the two monitoring stations assumed as contaminated locations in March/2015, radon concentrations were 1.17 ± 0.08 kBq.m{sup -3} and 4.2 ± 0.3 kBq.m{sup -3}, diminished in a range from 92% to 98% when compared with the results for the non-contaminated areas. (author)

  12. Monitoring of radon concentration in dwellings

    International Nuclear Information System (INIS)

    Kurosawa, Ryuhei

    1991-01-01

    Radon problems in dwellings have recently received much attention. Radon concentration in dwellings, as well as in the general environment, varies with various factors such as meteorological conditions and soil components. Therefore, a long term monitoring of radon concentration is required to obtain an average concentration. This paper reviews a passive type radon monitor that is handy and allows a long term radon monitoring. It provides the structure and principle of the radon monitor, covering the type, filter function, sensitivity of diffusion collecting type (cup type), electrostatic collecting type, adsorption collecting type, and detector of radon monitor. Actual examples of the radon monitor are also given. Radon daughter nuclides will have become major foci of exposure countermeasures. In the future, the development of a passive type monitor for determining potential alpha energy concentration is required. (N.K.)

  13. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  14. Radon risk in Alpine regions in Austria: Risk assessment as a settlement planning strategy

    International Nuclear Information System (INIS)

    Gruber, V.; Baumgartner, A.; Seidel, C.; Maringer, F. J.

    2008-01-01

    Soil gas radon measurements complement indispensable and well-established radon indoor measurements in Austria. Radon in soil gas is a result of geochemical conditions as well as of geology, mineralogy, geophysics and meteorology. Therefore, geological factors can help to predict potential indoor radon concentrations via soil gas. Soil gas radon measurements in well-defined geological units give an estimate of local and regional radon hazards and build the basis for radon risk maps, which could be used for land-use planning and urban development. The creation of maps makes an important contribution to health care. For this purpose, several research projects were carried out in Austria. On the one hand, a study was already conducted in Lower Austria to determine the influence of meteorological and soil physical parameters on radon concentrations in soil gas and to evaluate soil gas radon concentrations with a radon emanation and migration model. On the other hand, radon measurements on different geomorphologic formations in the Austrian Alps, which are potential settlement areas, are of special interest. (authors)

  15. The Pennsylvania radon story

    International Nuclear Information System (INIS)

    Gerusky, T.M.

    1987-01-01

    In December 1984, the Pennsylvania Bureau of Radiation Protection found itself confronted with the discovery of a home in eastern Pennsylvania having the highest level of radon daughters ever reported. The Bureau responded with a massive radon monitoring, educational, and remediation effort. As of November, 1986, over 18,000 homes had been screen for radon daughters, of which approximately 59% were found to have levels in excess of the 0.020 Working Level guideline. Pennsylvania's response to the indoor radon problem is detailed in this article

  16. Radon problems

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1985-01-01

    This chapter examines the health hazards resulting from the release of naturally occurring radioactive gas derived from the decay of uranium. It is estimated that random inhalation is now causing about 10,000 fatal lung cancers per year in the US. Radon is constantly being generated in rocks and soils (in which uranium is naturally present) and in materials produced from them (e.g., brick, stone, cement, plaster). It is emphasized that radon levels in buildings are typically 5 times higher than outdoors because radon diffusing up from the ground below or out of bricks, stone, cement, or plaster is trapped inside for a relatively long time

  17. Radon content in schools of Cluj and Onesti cities

    International Nuclear Information System (INIS)

    Cosma, C.; Rudei, Corina; Ciubotariu, Irina; Hening, Kinga

    2003-01-01

    Cluj-Napoca city is the most important city in the north-western part of Romania located in the hydrographic basin of the Somes River. The geologic structure of this hydrographic basin is characterized by a magmatic and metamorphic basement, visible on the north-eastern edge of Apuseni Mountains. The sedimentary layer, of Palaeocene to Middle Miocene age, comprises an alternation of red clays, marls and limestone evaporites and clastic rocks. The alluvial deposits of the Somes Valley mainly consist of magmatic and metamorphic material from Apuseni Mountains. Before reaching this city, the Somes River crosses a granitic massive called Maguri-Racatau, located at 35 km on the upper part of this water course. The first indications of a possible radon prone area for Cluj-Napoca city was the relatively high radon concentration (1 nCi/l) in the old water supply plant. This water supply plant has a network of about 100 wells drilled near riverbed of Somes River between Floresti and Cluj-Napoca at 4 km upstream of Cluj-Napoca. The water of these drillings is still used for water supply of Cluj-Napoca drinking water network together with the new Tarnita lake accumulation 20 km from Cluj-Napoca which collects the surface water from Apuseni Mountains. At present, the Cluj-Napoca city has about 350,000 inhabitants. A percentage of 25-30% live in detached houses with one or two levels built, as a rule, in red bricks. The major part of the population lives in blocks of flats with four or ten floors, the most important part being built of concrete, beginning with 1960. Indoor radon measurement was made using an integrating method of Karlsruhe type. After exposure the detectors were electrochemically etched at the Nuclear Physics Laboratory in Gent (Belgium). Indoor radon concentrations at ground floor have been measured in 46 detached houses, as well as radon concentrations in 35 flats in blocks. The average values found in Cluj city, of 183±75 Bq/m 3 for houses and of 69±23 Bq

  18. Unattached radon daughter atoms and radon daughter equilibrium ratios in uranium mines. Final report

    International Nuclear Information System (INIS)

    Holaday, D.A.

    1972-01-01

    Uranium mines in Colorado and New Mexico were surveyed for airborne concentrations of radon (10043922) and radon daughters. A procedure for measuring individual daughters and the fraction of each existing as free atoms was developed and used for field monitoring. Samples were taken in working areas and particle counts were made. The data was analyzed to determine the ratio of radon to radon daughters as well as the ratios among the radon daughters. The author concludes that since the radon to working level ratios have not changed much in 20 years, using the ratio as the basis for estimating relative biological hazard is just as uncertain now as then. The large number of daughters present as free atoms indicate that the lung radiation doses calculated using any of the lung models need reexamination

  19. Analysis of queuing mine-cars affecting shaft station radon concentrations in Quzhou uranium mine, eastern China

    Directory of Open Access Journals (Sweden)

    Changshou Hong

    2018-04-01

    Full Text Available Shaft stations of underground uranium mines in China are not only utilized as waiting space for loaded mine-cars queuing to be hoisted but also as the principal channel for fresh air taken to working places. Therefore, assessment of how mine-car queuing processes affect shaft station radon concentration was carried out. Queuing network of mine-cars has been analyzed in an underground uranium mine, located in Quzhou, Zhejiang province of Eastern China. On the basis of mathematical analysis of the queue network, a MATLAB-based quasi-random number generating program utilizing Monte-Carlo methods was worked out. Extensive simulations were then implemented via MATALB operating on a DELL PC. Thereafter, theoretical calculations and field measurements of shaft station radon concentrations for several working conditions were performed. The queuing performance measures of interest, like average queuing length and waiting time, were found to be significantly affected by the utilization rate (positively correlated. However, even with respect to the “worst case”, the shaft station radon concentration was always lower than 200 Bq/m3. The model predictions were compared with the measuring results, and a satisfactory agreement was noted. Under current working conditions, queuing-induced variations of shaft station radon concentration of the study mine are not remarkable. Keywords: Hoist and Transport Systems, Mine-cars, Queuing Simulation, Radon Concentration, Underground Uranium Mine

  20. Radon Research Program, FY-1990

    International Nuclear Information System (INIS)

    1991-03-01

    The Department of Energy (DOE) Office of Health and Environmental Research (OHER) has established a Radon Research Program with the primary objectives of acquiring knowledge necessary to improve estimates of health risks associated with radon exposure and also to improve radon control. Through the Radon Research Program, OHER supports and coordinates the research activities of investigators at facilities all across the nation. From this research, significant advances are being made in our understanding of the health effects of radon. OHER publishes this annual report to provide information to interested researchers and the public about its research activities. This edition of the report summarizes the activities of program researchers during FY90. Chapter 2 of this report describes how risks associated with radon exposure are estimated, what assumptions are made in estimating radon risks for the general public, and how the uncertainties in these assumptions affect the risk estimates. Chapter 3 examines how OHER, through the Radon Research Program, is working to gather information for reducing the uncertainties and improving the risk estimates. Chapter 4 highlights some of the major findings of investigators participating in the Radon Research Program in the past year. And, finally, Chapter 5 discusses the direction in which the program is headed in the future. 20 figs

  1. Radon - The management of the risk related to radon

    International Nuclear Information System (INIS)

    2010-01-01

    This leaflet briefly explains what radon is, where it comes from, and what it becomes. It indicates and briefly comments its concentrations in French departments, describes how radon can affect our health (lung cancer), describes how the risk can be reduced in buildings, and indicates the existing regulatory provisions

  2. Radon programmes and health marketing

    International Nuclear Information System (INIS)

    Fojtikova, I.; Rovenska, K.

    2011-01-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed. (authors)

  3. Radon in buildings

    International Nuclear Information System (INIS)

    Ryan, N.M.; Finn, M.

    1995-01-01

    This guide is intended to inform designers, contractors, householders and other building owners about radon in buildings and to provide guidance where it has been decided to take action to reduce radon levels. It gives some pointers to good practice insofar as it relates to non complex buildings of normal design and construction. Reference is made to the usual ways of reducing l;levels of radon and guidance is given on sources of further information. I

  4. Radon and thoron monitoring in the environment of Kumaun Himalayas: survey and outcomes

    International Nuclear Information System (INIS)

    Ramola, R.C.; Negi, M.S.; Choubey, V.M.

    2005-01-01

    Monitoring of radon, thoron and their daughter products was carried out in houses of Kumaun Himalaya, India using LR-115 plastic track detectors. The measurements were made in residential houses from June 1999 to May 2000 at a height of 2.5 m from ground level using a twin chamber radon dosimeter. The twin chamber radon dosimeter can record the values of radon, thoron and their decay products separately. Maximum and minimum indoor radon and thoron concentrations were evaluated and activity concentrations of radon and thoron daughters were estimated. The resulting dose rates due to radon, thoron and their decay products varied from 0.04 to 1.89 μSv/h. A detailed analysis of the distribution of radon, thoron and their decay products inside the house is also reported. The observed dose rates inside the houses of Kumaun Himalaya were found to be lower than the ICRP recommended value of 200 Bq/m 3 and thus are within safe limits

  5. Radon measurements in the interior of the great pyramid

    Energy Technology Data Exchange (ETDEWEB)

    Kenawy, M A; Morsy, A A [Ain Shams Univ., Cairo (Egypt). College for Girls

    1991-01-01

    Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).

  6. Radon measurements in the interior of the great pyramid

    International Nuclear Information System (INIS)

    Kenawy, M.A.; Morsy, A.A.

    1991-01-01

    Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author)

  7. Radon in dwellings the national radon survey Galway and Mayo

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.; O'Colmain, M.

    1999-07-01

    This report presents the results of the final phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Galway and Mayo. The average radon concentrations for the houses measured in these counties were 112 Bq/m 3 and 100 Bq/m 3 , respectively. The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  8. The use of mechanical ventilation with heat recovery for controlling radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Hollowell, C.D.; Roseme, G.D.

    1980-01-01

    An energy research house in Maryland was found to have radon concentrations far in excess of recommended guidelines. A mechanical ventilation system with heat recovery was installed in this house to test its effectiveness as an energy-efficient control technique for indoor radon. Radon concentration was monitored continuously for two weeks under varying ventilation conditions (0.07 to 0.8 air changes per hour (ach)) and radon daughter concentrations were measured by grab-sample techniques about nine times daily during this period. At ventilation rates of 0.6 ach and higher radon and radon daughter levels dropped below guidelines for indoor concentrations. Comparison with other studies indicates that indoor radon buildup may be a problem in a considerable portion of houses characterized by their low infiltration rates. The use of mechanical ventilation systems with air-to-air heat exchangers may offer a practical, cost-effective, and energy-efficient means of alleviating not only the radon problem specifically but also the general deterioration of indoor air quality in houses designed or retrofitted to achieve low infiltration

  9. Distribution of indoor radon concentrations and uranium-bearing rocks in Texas

    International Nuclear Information System (INIS)

    Hudak, P.F.

    1996-01-01

    The purpose of this study was to compare regional patterns of indoor radon concentration with uranium-bearing rock zones and county populations in Texas. Zones yielding radon concentrations that are relatively high for Texas include shale and sandstone in northwest Texas; red beds in north-central Texas; felsic volcanic rocks in west Texas; and sandstone, limestone, and igneous rocks in central Texas. Located in northwest Tecas, only five of the 202 counties evaluated have mean indoor radon concentrations above 4.0 pCi l -1 . Two of those counties have populations above the state median of 20115. The highest county mean concentration is 8.8 pCi l -1 . Results of the study suggest that (1) regional geology influences indoor radon concentrations in Texas, (2) statewide, the radon concentrations are relatively low, (3) highly populated counties do not coincide with regions of high indoor radon concentration, and (4) regions that may warrant further monitoring include northwest Texas and, to a lesser degree, west and central Texas. (orig.)

  10. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  11. The survey of dwellings with increased radon levels in Slovakia

    International Nuclear Information System (INIS)

    Vicanova, M.

    1998-01-01

    This national survey of indoor radon measurements in a sample of dwellings in Slovakia was organised by the Institute of Preventive and Clinical Medicine in Bratislava. The aim was to find districts and type of dwellings with the highest indoor radon concentrations and to estimate the radiation load of the Slovak population owing the indoor radon exposure. Passive solid state nuclear track detectors were used to measure indoor radon concentrations. The detectors were polyallyldiglycolcarbonate CR-39 which were placed in about 6,000 selected houses (minimum two detectors for every residence). After six months exposed detectors and questionnaires were returned to for analysis. Electrochemical etching combined with a chemical pre-etching process was used for evaluating detectors. Present results are from 3,657 residents (0.2% of total dwellings in Slovakia). It was found that the arithmetic mean of equilibrium equivalent concentration (EEC) was 86 ± 119 Bq m -3 , the geometric mean was about 41 ± 2.22 Bq m -3 and 11% of dwellings (N = 409) have a greater EEC of radon than the action level (200 Bq m -3 ). The national survey results suggest that Slovakia may be among the countries with high radon risk in Central Europe. The population-weighted arithmetic mean is 48 Bq m -3 , the maximum value found was 1500 Bq m -3 and the average annual effective dose from indoor radon exposure is 2.1 mSv. The district with the highest indoor radon concentrations correlate with known presence of uranium in the soil, therefore the soil is probably the main source of radon in Slovak dwellings. This survey of dwellings with increased radon levels supported this conclusion, because the highest radon levels were found in older family houses without cellars. (author)

  12. Development and management of a radon assessment strategy suitable for underground railway tunnelling projects

    International Nuclear Information System (INIS)

    Purnell, C. J.; Frommer, G.; Chan, K.; Auch, A. A.

    2004-01-01

    The construction of underground tunnels through radon-bearing rock poses a radiation health risk to tunnelling workers from exposure to radon gas and its radioactive decay products. This paper presents the development and practical application of a radon assessment strategy suitable for the measurement of radon in tunnelling work environments in Hong Kong. The assessment strategy was successfully evaluated on a number of underground railway tunnelling projects over a 3 y period. Radon measurements were undertaken using a combination of portable radon measurement equipment and track etch detectors (TEDs) deployed throughout the tunnels. The radon gas monitoring results were used to confirm that ventilation rates were adequate or identified, at an early stage, when further action to reduce radon levels was required. Exposure dose estimates based on the TED results showed that the exposure of tunnel workers to radon did not exceed 3 mSv per annum for the duration of each project. (authors)

  13. Radon and radiation biology of the lung

    International Nuclear Information System (INIS)

    Crameri, R.; Burkart, W.

    1989-01-01

    The main papers presented at the meeting dealt with the behaviour of radon and the indoor environment, radiation biology of the lung, lung dosis and the possible cancer risk caused by radon in homes, contamination of the room air. A series of special papers treated the radon problem in detail: sources and transport mechanisms of radon, geological aspects of the radon radiation burden in Switzerland, radon in homes, search for radon sources, and the Swiss radon-programme RAPROS. 67 figs., 13 tabs., 75 refs

  14. Multivariate signal processing in measurements of radon and radon daughters in air

    International Nuclear Information System (INIS)

    Urbanski, P.; Machaj, B.

    2000-01-01

    Extensive measurements of radon and radon daughters concentration gauge in a radon chamber were carried out. Count rate 'spectra' against time at the output of radiation detectors were measured and registered. The count rate spectra were then processed employing Principal Component Regression (PCR). A root mean square error of the count rate was estimated. It was found that PCR processing removes a great part of count rate random fluctuations originating from the radiation statistics that results in a decrease of count rate random error. The root mean square error of count rate in a radon daughter monitor is about 3 times lower, which is equivalent to the error of the gauge with a 9 times higher air flow rate if no PCR processing is used. In case of the radon concentration gauge the increase of sensitivity is even higher and amounts to 5 times. (author)

  15. Radon in water - fast, simple and sensitive measurement

    International Nuclear Information System (INIS)

    Philipsborn, H. von

    1996-01-01

    Glass fiber filters of a certain brand were found to be very efficient (retention >95%) for adsorption of short-lived radon decay products during filtration of water. Limit of detection is 2 Bq/L in 10 min total time if the dried filters are evaluated in the Living Level Monitor mab LLM 500. Locally high radon concentrations in drinking water have activated country-wide surveys and proposals for compulsory action levels. (orig.) [de

  16. Radon measurements in indoor workplaces

    International Nuclear Information System (INIS)

    Tokonami, S.; Matsumoto, M.; Furukawa, M.; Fujimoto, K.; Fujitaka, K.; Pan, J.; Kurosawa, R.

    1996-01-01

    Radon measurements in several office buildings located in Tokyo were carried out with two types of device to study the time-dependent radon concentration in indoor workplaces. Both types of device use the electrostatic field for the collection of 218 Po onto the electrode of the detector. One provides an average radon concentration throughout the day. The other, in which a weekly timer is installed in the circuit of the electrode of the device, provides an average radon concentration during working hours (9:00-17:00, Monday-Friday). Although radon concentrations in Japanese dwellings have been found to be generally low, relatively high concentrations were observed in the office buildings. No consistent seasonal variation was recognised in this study. Little difference of average radon concentrations between working hours and the whole day was found throughout the year in two offices. On the other hand, a significant difference was observed in other offices. The operation of an air conditioner might change the radon concentration during working hours. From the results of radon measurements the average effective dose in the workplace was estimated to be 0.23 mSv for 2000 working hours in a year. (Author)

  17. Radon studies in Indian dwellings

    International Nuclear Information System (INIS)

    Khan, A.J.

    2000-01-01

    The indoor radon ( 222 Rn) concentration has been measured by Solid State Nuclear Track Detectors (SSNTDs) in large number of Indian dwellings. Radon concentrations were measured in different parts of the country. In the first study, radon concentrations were measured in 143 dwellings of Udaipur, Bikaner and Banswara towns of Rajasthan province. The distributions of the time-averaged indoor radon concentration in these three towns of the Rajasthan fit an approximately log normal distribution. The geometric mean (GM) values of radon concentrations in these three places were found to be 74 Bq m -3 , 46 Bq m -3 and 66 Bq m -3 with a geometric standard deviation (GSD) of 2.2, 2.2 and 2.5 respectively. In another study, radon concentrations were measured in about 150 dwellings of hilly regions of the country. The measurements were carried out in Kohima (Nagaland), Baijnath and Palampur (Himachal Pradesh). The distribution of radon concentration in Kohima dwellings was found to be approximately log normal, however, the radon distribution in Baijnath and Palampur dwellings seems to be bimodal. The GM values of the radon concentrations for 65 dwellings in Kohima and 43 dwellings in Baijnath and Palampur were 88 Bq m -3 and 134 Bq m -3 with GSD of 1.7 and 2.5 respectively. The results are discussed in detail. (author)

  18. Radon prevention coating in hot and humid environment

    International Nuclear Information System (INIS)

    Yang Yushan; Dong Faqin; Deng Yuequan; Qu Ruixue

    2013-01-01

    The radon prevention performance of a new self-made radon prevention coating was researched in the radon contamination provided by the releasing radon modules. With coating thickness of 0.8 mm, the radon mitigation efficiency in 1 # radon module concentration is optimal when the addition of defoaming agent is 0.3% (mass fraction). The radon mitigation efficiency increases with the coating thickness when the defoaming agent of 0.3% is added, but the radon mitigation efficiency tends to be stable as the coating thickness is more than 2.0 mm. The radon mitigation efficiency of radon prevention coating appended precipitated barium sulphate decreases obviously, and the addition of ash calcium, white cement and gesso don't decrease radon mitigation efficiency. The addition of white cement and gesso addition affects the radon prevention stability, while radon mitigation efficiency of radon prevention coating with ash calcium keeps a good performance. Under the hot and humid environment, the radon prevention coating still has good radon mitigation efficiency in 2 # radon module concentration. (authors)

  19. Cost-effectiveness analysis of radon remediation in schools

    International Nuclear Information System (INIS)

    Kennedy, C.A.; Gray, A.M.

    2000-01-01

    Indoor radon is an important source of radiation dosage in the general population and has been recognised as a world-wide environmental and public health challenge. Governments in many Western and Eastern European and North American countries are undertaking active radon-risk reduction policies, including the remediation of existing residential and work place building stocks (1). These endeavours include a priority of remediating school buildings. Epidemiological and technical radon research has produced information which has enabled attention to be turned to specific effectiveness and optimisation questions regarding radon identification and remediation programmes in buildings, including schools. Decision making about policy implementation has been an integral part of these programmes and questions have been raised about the economic implications of the regulations and optimisation strategies for workplace action level policy (2,3). (the action level applied to schools is 400 Bq m -3 ). No previous study has estimated the cost-effectiveness of a radon remediation programme for schools using the methodological framework now considered appropriate in the economic evaluation of health interventions. It is imperative that this should be done, in order that the resources required to obtain health gain from radon remediation in schools can be systematically compared with equivalent data for other health interventions and radon remediation programmes. In this study a cost-effectiveness analysis of radon remediation in schools was undertaken, using the best available national data and information from Northamptonshire on the costs and effectiveness of radon identification and remediation in schools, and the costs and health impact of lung cancer cases. A model based on data from Northamptonshire is presented (where 6.3% of residential stock is over 200 Bq m -3 ). The resultant cost-effectiveness ratio was pound 7,550 per life year gained in pound 1997. Results from the

  20. Radon in homes: The Alaskan experience

    International Nuclear Information System (INIS)

    Seifert, R.D.

    1990-01-01

    For the past four years, since radon was first found to be a concern in Alaska in 1986, the interest and awareness of radon as a special housing and health concern has continued to grow. This paper will discuss the features of a house in Alaska which would characterize it as at risk for radon, and also those efforts at mitigation which have been most effective in reducing radon under Alaskan conditions. Clearly radon must be able to enter a home in order to be a problem. Riefenstuhl and Kline (personal communication, 1988) have analyzed the conditions for radon transport from soils to home interiors very lucidly through the following scheme: four factors must exist in a house locale for it to be a radon at risk house. Two of the factors are geological in nature: (1) there must be adequate uranium and therefore ample radon to provide a source for transport; (2) there must be enough permeability in the soil to allow rapid soil gas movement to carry radon from its origin to the interior of the home within two half-lives of time (six days) or so. The other two factors are determined by the structure of the house itself and the way in which it is operated: (3) the house must have soil contact and imperfections, holes, cracks, intentional perforations which allow movement of soil gas with radon through the envelope of the basement or crawlspace; (4) there must be a lower pressure inside the house than in the soil so that soil gas flows into the house. All four of these characteristics are required to have radon be a problem. The absence of any single characteristic will eliminate radon (in general). This presents a series of options for mitigation of radon then, since elimination of any of the four characteristics will mitigate radon

  1. Efficient measurement of radon daughters

    International Nuclear Information System (INIS)

    Rolle, R.

    1992-01-01

    In environmental control there is an increasing need for efficient measurement of radon and thoron daughters in air. Measuring instruments should be rugged and portable for field use, while also permitting unattended operation for several days. Simple operating procedures should permit evaluation of rapidly changing concentrations over extended periods. These requirements demand careful balance in the design of hardware and measuring procedures. The design principles for a continuous flow-through spectrometer, that has been developed for precision sequential measurement of radon and thoron daughters, are described. Because of the high precision of measurement, this type of instrument should find application in environments from technologically enhanced natural radiation to the very lowest natural background situations. (author)

  2. Radon measurements of groundwater in Mexico

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J.I.; Cortes, A.

    1991-01-01

    Radon measurement has important applications in hydrogeological studies. Specifically, radon measurement is used to determine the fluctuations of the piezometric levels in groundwater and, in some cases, the path of the water, which is one of the key parameters for evaluating hydrogeological resources. Water from springs and deep wells in the Basin of Mexico and the valley of San Luis Potosi were sampled, measured and analyzed by previous authors. In this work, a method for measuring 222 Rn in groundwater by using a passive detector is presented and the results are compared with a similar experiment performed at the same time, using a dynamic method. The aim of the work is to develop a method for detecting, evaluating and measuring the 222 Rn in groundwater by using SSNTD technology. (author)

  3. Automatically processed alpha-track radon monitor

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1993-01-01

    An automatically processed alpha-track radon monitor is provided which includes a housing having an aperture allowing radon entry, and a filter that excludes the entry of radon daughters into the housing. A flexible track registration material is located within the housing that records alpha-particle emissions from the decay of radon and radon daughters inside the housing. The flexible track registration material is capable of being spliced such that the registration material from a plurality of monitors can be spliced into a single strip to facilitate automatic processing of the registration material from the plurality of monitors. A process for the automatic counting of radon registered by a radon monitor is also provided

  4. The householders' guide to radon

    International Nuclear Information System (INIS)

    1988-06-01

    This guide is a follow-up to the leaflet Radon in Houses which was issued previously by the Department of the Environment. It is intended for people who live in areas with high levels of radon. It is written particularly for householders whose homes have already been tested and found to have an appreciable level of radon. It explains what radon is, how it gets into houses and what the effects on health may be. It also outlines some of the ways of reducing the level of radon and gives guidance both on how to get the work done and likely costs. (author)

  5. Radon surveys and their implications

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Cliff, K.D.; Dixon, D.W.; Green, B.M.R.; Strong, J.C.

    1989-01-01

    In the UK, as in other countries, radon daughter inhalation is the most significant cause of human exposure to ionising radiation either at home or at work whether one considers the mean or the maximum dose. Substantial studies of radon are under way in the UK, and the importance of radon is recognised in several spheres. NRPB investigations of the radon levels in buildings and mines are reported, the distributions of doses presented and risk factors calculated. The bases of radon limitation for workers and members of the public are given and the means of compliance discussed. (author)

  6. Study of radon emanation from uranium mill tailings. Relations between radon emanating power and physicochemical properties of the material

    International Nuclear Information System (INIS)

    Pellegrini, D.

    1999-01-01

    The uranium extraction from ores leads to large amounts of mill tailings still containing radionuclides, such as thorium-230 and radium-226, which generate radon-222. Without protective action, radon exposition may be high enough to cause concern for health of populations living in the vicinity of an uranium mill tailings disposal. This exposition pathway has therefore to be taken into account in the radiological impact studies. The emanating power, i.e. the part of radon atoms which escape from the solid particles, is directly involved in the radon source term evaluation. It may be determined for a given material by laboratory measurements. Emanating powers from 0.08 to 0.33 have been obtained for mill tailings from Jouac (Limousin, France), at various moisture contents. In order to reduce the relations of dependence between some of the emanation parameters, more simple phases, kaolinite and polymeric resins, have been studied. Those experiments have led us to the selection of the mechanisms and the parameters to consider for the development of an emanation modelling. The whole of the results obtained point out the radon sorption, in various proportions depending on the materials. The moisture content influence on the emanation from materials containing fine particles have been confirmed: the emanation increases with this parameter until a continuous water film surrounding the particles have been formed, and then become constant. This 'water effect' occurs in a moisture content range, which depends on the material porosity. Elsewhere, the presence of amorphous phases may led to a high radon emanation. (author)

  7. Radon exposure and lung cancer

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Faj, Z.; Radolic, V.; Suveljak, B.

    2003-01-01

    Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km 2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample. (author)

  8. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    International Nuclear Information System (INIS)

    Momeni, M.H.; Lindstrom, J.B.; Dungey, C.E.; Kisieleski, W.E.

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m 3 on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m 3 . Average working-level background is 3.6 x 10 -3

  9. Exposure to radon Rn-222 of inhabitants of buildings in Olsztyn

    International Nuclear Information System (INIS)

    Gorzkowski, B.; Pachocki, K.; Rozycki, Z.; Majle, T.; Pensko, J.; Krzeslak, A.

    1998-01-01

    The concentrations of radon-222 in the air of some buildings in Olsztyn were measured. The main source of radon in buildings is in general the ground under building and the materials used for building structure. In this work the results of radon-222 concentration measurements in the air of some buildings constructed before the 1939 year, in the buildings constructed after 1945 year with the traditional use of the bricks and in the buildings constructed with the use of great prefabricated plates are presented. The relations between radon-222 concentrations in the basements and in the first floor flats situated above the basement were evaluated. Based on the mean radon concentrations in the air of the various types of buildings investigated the effective doses for the inhabitants of each type of buildings were estimated. (author)

  10. Consumer's Guide to Radon Reduction

    Science.gov (United States)

    ... Labs and Research Centers Radon Contact Us Share Consumer's Guide to Radon Reduction: How to Fix Your ... See EPA’s About PDF page to learn more. Consumer's Guide to Radon Reduction: How to Fix Your ...

  11. Canadian individual risks of radon-induced lung cancer for different exposure profiles.

    Science.gov (United States)

    Chen, Jing

    2005-01-01

    Indoor radon has been determined to be the second leading cause of lung cancer after tobacco smoking. There is an increasing need among radiation practitioners to have numerical values of lung cancer risks for men and women, ever-smokers and never-smokers exposed to radon in homes. This study evaluates individual risks for the Canadian population exposed to radon in homes at different radon concentrations and for different periods of their lives. Based on the risk model developed recently by U.S. Environmental Protection Agency (EPA), individual risks of radon-induced lung cancers are calculated with Canadian age-specific rates for overall and lung cancer mortalities (1996-2000) as well as the Canadian smoking prevalence data in 2002. Convenient tables of lifetime relative risks are constructed for lifetime exposures and short exposures between any two age intervals from 0 to 110, and for various radon concentrations found in homes from 50 to 1000 Bq/m3. The risk of developing lung cancer from residential radon exposure increases with radon concentration and exposure duration. For short exposure periods, such as 10 or 20 years, risks are higher in middle age groups (30-50) compared especially to the later years. Individuals could lower their risks significantly by reducing radon levels earlier in life. The tables could help radiation protection practitioners to better communicate indoor radon risk to members of the public.

  12. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  13. Radon programme in the Czech Republic

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    2003-01-01

    The framework of the Radon programme in the Czech republic includes both precautionary measures and interventions. The programme informally started in early eighties has been now incorporated in national legislation (Atomic Act, Radiation Protection Decree, etc.). Aim of precautionary measures is to avert construction of building above natural radiation guidance levels (200 Bq/m 3 for indoor radon concentration and 0.5 Sv/h for gamma dose rate) by protection of new buildings against soil radon ingress, by regulation of natural radioactivity in building materials and supplied water. Aim of interventions is to identify buildings affected by enhanced natural radioactivity and help owners to put into effect reasonable remedial measures. Two sets of intervention levels for indoor natural exposure were established: guidance intervention levels 400 Bq/m 3 (indoor radon), 1.0 Sv/h (indoor gamma dose rate) and limit values 4000 Bq/m 3 and 10 Sv/h. The radon programme is based both on governmental and private activities. The governmental activities include representative and targeted indoor radon survey, subsidy for radon mitigation, mitigation test measurements and public information on radon issue. The private activities include radon measurement (radon index of building site, indoor measurements, radon diagnosis) and remedial measures. More than 100 commercial companies were authorised by Radiation Protection Authority (SUJB) to provide these measurements

  14. Radon in dwellings in selected areas of Ireland

    International Nuclear Information System (INIS)

    Madden, J.S.; Duffy, J.T.; Mackin, G.A.; Colgan, P.A.; McGarry, A.T.

    1994-10-01

    This report presents and interprets the results of surveys of domestic radon concentrations carried out by the Radiological Protection Institute of Ireland between 1989 and 1992. Data from low-density monitoring surveys in counties Mayo, Galway (including the Aran Island of Inis Mor) and Clare and in north Kerry, in addition to more detailed surveys in Moycullen and Salthill in Co. Galway and south Cork city are presented. The highest seasonally-corrected radon level found in any of the 1755 dwellings surveyed was 2399 Bq/m 3 . This is twelve times the national Reference Level of 200 Bq/m 3 , and corresponds to an annual radiation dose to occupants of the house of 60 mSv, three times the maximum dose which radiation workers are allowed to receive under internationally-accepted standards. Statistical evaluation of the data has allowed classification of 10 km grid square areas on the basis of the predicted proportion of houses in each grid square with radon levels in excess of the national Reference Level, 200 Bq/m 3 . The most affected areas occur in counties Mayo and Galway, and to a lesser extent in south-east Cork city. In county Galway six grid squares are predicted to have more than 20% of houses with radon concentrations in excess of 200 Bq/m 3 . In the most affected grid square 30% of houses are predicted to have radon concentrations in excess of this level. It is important that householders in these areas be strongly encouraged to have the radon levels in their houses measured in order to identify the individual houses in which remedial measures are required. The risk associated with longterm exposure to radon has been calculated using the latest risk factor recommended by the International Commission on Radiological Protection. For average residents exposed to indoor radon concentrations of 200 Bq/m 3 the estimated lifetime risk of premature death from lung cancer, due to radon, is about 2%. This risk is a significant addition to the prevailing lifetime

  15. Radon survey techniques

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The report reviews radon measurement surveys in soils and in water. Special applications, and advantages and limitations of the radon measurement techniques are considered. The working group also gives some directions for further research in this field

  16. Comparison of retrospective and contemporary indoor radon measurements in a high-radon area of Serbia

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Yarmoshenko, I.V.; Kelleher, K.; Paridaens, J.; Mc Laughlin, J.P.; Celikovic, I.; Ujic, P.; Onischenko, A.D.; Jovanovic, S.; Demajo, A.; Birovljev, A.; Bochicchio, F.

    2007-01-01

    In Niska Banja, Serbia, which is a high-radon area, a comparison was made between two retrospective radon measuring methods and contemporary radon measurements. The two retrospective methods derive the radon concentrations that occurred in dwellings over longer periods in the past, based on the amount of trapped 210 Po on the surface of glass objects (surface traps, ST) or in the bulk of porous materials (volume traps, VT). Both surface implanted 210 Po in glass objects and contemporary radon in air were measured in 46 rooms, distributed in 32 houses of this radon spa-town, using a dual alpha track detector configuration (CR-39 and LR115) and CR-39 track etched detectors, respectively. In addition to the use of surface trap measurements, in 18 rooms (distributed in 15 houses) VT samples of suitable material were also collected, allowing to compare ST and VT retrospective radon concentration estimates. For each room, contemporary annual radon concentrations (CONT) were measured or estimated using seasonal correction factors. The distribution of the radon concentration in all data sets was found to be close to lognormal (Chi-square test > 0.05). Geometric means (GM) are similar, ranging from 1040 to 1380 Bq m -3 , whereas geometric standard deviations (GSD) for both the retrospective methods are greater than for the CONT method, showing reasonable agreement between VT, ST and CONT measurements. A regression analysis, with respect to the lognormal distribution of each data set, shows that for VT-ST the correlation coefficient r is 0.85, for VT-CONT r is 0.82 and for ST-CONT r is 0.73. Comparison of retrospective and contemporary radon concentrations with regard to supposed long-term indoor radon changes further supports the principal agreement between the retrospective and conventional methods

  17. The use of track registration detectors to reconstruct contemporary and historical airborne radon ( sup 2 sup 2 sup 2 Rn) and radon progeny concentrations for a radon-lung cancer epidemiologic study

    CERN Document Server

    Steck, D J

    1999-01-01

    Epidemiologic studies that investigate the relationship between radon and lung cancer require accurate estimates for the long-term average concentrations of radon progeny in dwellings. Year-to-year and home-to-home variations of radon in domestic environments pose serious difficulties for reconstructing an individual's long-term radon-related exposure. The use of contemporary radon gas concentrations as a surrogate for radon-related dose introduces additional uncertainty in dose assessment. Studies of glass exposed in radon chambers and in a home show that radon progeny deposited on, and implanted in, glass hold promise for reconstructing past radon concentrations in a variety of atmospheres. We developed an inexpensive track registration detector for the Iowa Radon Lung Cancer Study (IRLCS) that simultaneously measures contemporary airborne radon concentrations, surface deposited alpha activity density, and implanted sup 2 sup 1 sup 0 Po activity density. The implanted activity is used to reconstruct the cum...

  18. E-perm radon monitors for determining waterborne concentrations of dissolved in radon 222Rn

    International Nuclear Information System (INIS)

    Jester, W.A.; Kotrappa, P.

    1989-01-01

    This paper describes a simple and relatively inexpensive method in which E-Perm radon monitors are used to determine the concentration of dissolved 222 Rn in drinking water. This procedure takes advantage of E-Perm's ability to accurately measure the integral radon exposure under conditions of high humidity. The method was evaluated against the liquid scintillation procedure recommended by the U.S. Environmental Protection Agency (EPA) and was found to give excellent agreement. An E-perm is an electret ion chamber that consists of a small chamber constructed from a conducting plastic and having an electret at its base and a filtered air inlet at the top. The technique described in this paper takes advantages of E-Perm's insensitivity to high humidity

  19. Residential radon in Kansas City-black shales aren't the prime suspect

    International Nuclear Information System (INIS)

    Spencer, C.G.

    1993-01-01

    The US EPA preliminary assessment of potential radon risk (EPA, 1986) depicted a large area of the mid-continent in which radon levels might be elevated due to the presence of uranium-rich black shales. A preliminary study (Hilpman, Coveney ampersand Spencer, 1988) indicated that a significant percentage of homes in the greater Kansas City area had radon screening levels above 4 pCi/L. However, their lab tests with crushed black shale, and radon tests in limestone mines with black shale floors showed that the shale did not yield extremely high radon levels. This expanded study presents additional results of screening tests in homes, and correlates those results to bedrock geology and soil type. High radon levels in the Kansas city area are not due primarily to black shale sources. The highest readings are associated with limestone and non-organic shale. Mean radon level is higher in younger cyclothemic deposits, and a loessial soil. The EPA initial assessment overstated the radon risk attributable to black uraniferous shale sources. Assessment of the overall potential risk for the greater Kansas City area requires further evaluation of other sources

  20. An Alpha spectrometer for measuring radon daughter individual activity concentration

    International Nuclear Information System (INIS)

    Berico, M.; Formignani, M.; Mariotti, F.

    2001-01-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of 218 Po, 214 Pb and 214 Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated [it

  1. Diurnal Variation of Radon Concentration in the Postojna Cave

    International Nuclear Information System (INIS)

    Gregoric, A.; Vaupotic, J.

    2011-01-01

    Postojna Cave, with 20 km of galleries, is the longest known cave system and also the largest of about 20 show caves in Slovenia and one of the most visited show caves in the world. It is well known that high concentrations of radon are common in karstic caves, although quantities of uranium (238U) in limestone are rather low. The reason for this is low natural ventilation of the underground cavities. Tectonic faults constitute an additional source of radon. Variations of radon concentration in cave air arise from a balance of the emission from cave surfaces and drip waters, decay in cave air, and exchange with the outside atmosphere. Because of its elevated radon concentrations, Postojna Cave has been under permanent radon survey since 1995. The influence of meteorological conditions on the radon levels and their temporal variations depends mostly on the shape of the cave, and the number and directions of cracks, corridors and fissures connecting the cave rooms with the outside atmosphere. The driving force for air movement in horizontal caves, and thus the inflow of fresh air and release of the cave air to the atmosphere, is the temperature difference between the cave air and outdoors, which causes seasonal pattern of radon concentration in the cave with high levels in summer and low in winter. However, on a daily scale different behaviour of radon can be observed at different locations in the cave. In this paper diurnal variation of radon concentration at two locations is presented and discussed. Postojna Cave is a horizontal cave with a stable yearly temperature around 10 degrees of @C. Continuous measurements of radon concentration were carried out from 2005 to 2010 at two locations along the guided tourist trail. Radon concentration was measured with Radim 5 WP monitors (SMM Company, Prague, Czech Republic) with sampling frequency once an hour. The evaluation of five-year radon monitoring at two sites in the Postojna Cave reveals significant diurnal and

  2. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  3. Metrology of the radon in air volume activity at the italian radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M. [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia Roma (Italy)

    2006-07-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of {sup 222}Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m{sup 3}. The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  4. Metrology of the radon in air volume activity at the italian radon reference chamber

    International Nuclear Information System (INIS)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M.

    2006-01-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of 222 Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m 3 . The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  5. Social marketing and the reduction of indoor radon

    International Nuclear Information System (INIS)

    Bierma, T.J.; Swartzman, D.

    1990-01-01

    Indoor radon monitoring and mitigation has apparently been conducted by only a small percentage of private homeowners despite extensive media coverage of the radon issue and public information programs at the federal, state, and local levels. Whether public education programs should be informative or persuasive is an ethical decision. Arguments on each side of the issue are presented. A framework for the development of a persuasive campaign is then presented, suing the concepts of social marketing and the limited empirical evidence available on radon-related behavior. In this paper a four-step process is proposed: identify problem dimensions using focus groups and other methods, confirm dimension for market segmentation using probability samples and factor analysis, implement program and evaluate and revise

  6. Radon survey in Metropolitan Toronto schools

    International Nuclear Information System (INIS)

    Becker, E.; Moridi, R.

    1992-01-01

    The radon testing survey in Metropolitan Toronto public schools was the most intensive project of its kind ever undertaken in Canadian schools. It also included an extensive public education program on radiation and radon-in-schools. The radon levels at 632 schools were measured using the CAIRS Radon Monitors. Ninety percent of the locations measured were found to have a radon level equal to or less than 2 mWL. Two locations in two different schools were found to have a radon level at or above the Action Level (20 mWL). The remaining results were between the two extremes. Follow-up testing in those schools where more than 10 mWL of radon was found is in progress. (author)

  7. Radon Survey in Hospitals in Slovenia

    International Nuclear Information System (INIS)

    Vaupotic, J.

    2003-01-01

    In Slovenia, several radon studies at workplaces have been carried out in last years, supported by the Ministry of Education, Science and Sport, and the Ministry of Health. After radon surveys in kindergartens, schools and homes, within which about 2600 buildings were checked for radon and which provided the level of radon problem in the country, next investigations were focused on the workplaces with potentially higher radon risk. Hence, in the Postojna Cave permanent radon monitoring was introduced in 1995 and comprehensive radon studies were performed: in 5 bigger spas during 1996-1998, in major waterworks and wine cellars in 2001, and in major Slovene hospitals in 2002. This paper reports the results of radon study in 26 major Slovene hospitals, comprising radon concentrations in 201 rooms and dose estimates for 1025 persons working in these rooms. Radon survey in 201 rooms of 26 major hospitals in Slovenia revealed only 7 rooms in which monthly average radon concentration in the indoor air exceeded 400 Bqm -3 . Generally, concentrations in basement were on average for about 30% higher than in ground floor, although exceptionally high values have also been found in the ground floor. For 966 persons (94.2%) of the total of 1025 persons working in the rooms surveyed, the annual effective dose, estimated according to the Basic Safety Standards was below 1 mSv, while for 59 it exceeded 1 mSv. In 7 rooms with more than 400 Bqm -3 in which 16 persons receive between 2.1 and 7.3 mSv per year radon monitoring is continued. (author)

  8. Radon: Residential attitudes toward the risk

    International Nuclear Information System (INIS)

    Fort, R.; Hinman, G.; Rosenman, R.; Wandschneider, P.

    1990-01-01

    Veradale, Washington (east of Spokane) is a region of high residential radon concentrations. Three hundred eighty residents of Veradale recently responded to a mail survey designed to elicit (1) their knowledge of and attitudes toward the risks of radon in their homes, (2) the actions they have taken or intend to take to identify and reduce those risks, and (3) policy preferences toward radon. Results reveal that these residents know that they live in an area with high radon levels, that radon causes lung cancer, and that radon will affect their health. However only 11% of respondents have had their homes tested for radon. This especially is puzzling because a large number of respondents claimed that (1) radon was important in home buying decisions, (2) they would test their own homes, (3) they would take action if such tests revealed problems, and (4) their willingness to pay for tests and improvements was well within the current costs of these actions. It remains a mystery why testing is at such a low level. Three other results are of note. First, subsidies for radon tests and home improvements may be having the unintended consequences of unneeded improvements and (potentially) moves without improvements. Second, individuals want radon testing required and results made known during home purchase decisions. Third, at present, weatherization programs that concentrate radon are acceptable to individuals. Of course, the future may hold different results. Administrators of weatherization programs, who are trusted by respondents according to this survey, would do well to institute weatherization programs with reduced radon concentrations in mind

  9. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  10. Indoor radon concentration in Poland

    International Nuclear Information System (INIS)

    Mamont-Ciesla, K.; Jagielak, J.; Rosinski, S.W.; Sosinka, A.; Bysiek, M.; Henschke, J.

    1996-01-01

    Preliminary survey of Rn concentration indoors by means of track detectors and y-ray dose rate with the use of TLD in almost 500 homes in selected areas of Poland was performed in the late 1980s. It was concluded that radon contributes 1.16 mSv i.e. about 46 per cent of the total natural environment ionizing radiation dose to the Polish population. Comparison of the average radon concentrations in 4 seasons of a year and in 3 groups of buildings: masonry, concrete and wood, revealed that the ground beneath the building structure is likely the dominant source of radon indoors. Since the National Atomic Energy Agency in its regulations of 1988-03-31 set up the permissible limit of the equilibrium equivalent concentration of radon in new buildings (equal 100 Bq/m3), the nation-scale survey project for radon in buildings has been undertaken. These regulations were supposed to take effect in 1995-01-01. The project has 3 objectives: to estimate the radiation exposure due to radon daughters received by Polish population to identify radon-prone areas in Poland to investigate dependence of the indoor radon concentrations on such parameters as: type of construction material, presence (or absence) of cellar under the building, number of floor

  11. Airborne geophysical radon hazard mapping

    International Nuclear Information System (INIS)

    Walker, P.

    1993-01-01

    Shales containing uranium pose a radon health hazard even when covered by several meters of overburden. Such an alum shale in southern Norway has been mapped with a joint helicopter borne electromagnetic (HEM) and radiometric survey. Results are compared with ground spectrometer, radon emanometer and radon gas measurements in dwellings, and a model to predict radon gas concentrations from the airborne data is developed. Since the shale is conductive, combining the HEM data with the radiometric channel allows the shale to be mapped with greater reliability than if the radiometric channel were used alone. Radiometrically more active areas which do not pose a radon gas hazard can thus be separated from the shales which do. The ground follow-up work consisted of spectrometer and radon emanometer measurements over a uranium anomaly coinciding with a conductor. The correlation between the airborne uranium channel, the ground uranium channel and emanometry is extremely good, indicating that airborne geophysics can, in this case, be used to predict areas having a high radon potential. Contingency tables comparing both radon exhalation and concentration in dwellings with the airborne uranium data show a strong relationship exists between exhalation and the airborne data and while a relationship between concentration and the airborne data is present, but weaker

  12. Instrumentation for a radon research house

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Revzan, K.L.; Robb, A.W.

    1981-07-01

    A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations

  13. Contribution of waterborne radon to home air quality

    International Nuclear Information System (INIS)

    Deb, A.K.

    1994-01-01

    Radon-222 is a member of the uranium decay chain and is formed from the decay of radium-226. Radon and its decay products emit alpha particles during the decay process. If radon is inhaled, alpha particles emitted from inhaled radon and its daughters increase the risk of lung cancer. Radon is soluble in water; thus when radon comes in contact with groundwater it dissolves. The radon concentration in groundwater may range from 100 pCi/L to 1,000,000 pCi/L. When water with a high radon level is used in the home, radon is released from the water to the air and thus can increase indoor air radon concentration. Considering the estimated health risk from radon in public water supply systems, EPA has proposed a maximum contaminant level (MCL) of 300 pCi/L for radon in public drinking water supplies. To address the health risks of radon in water and the proposed regulations, the American Water Works Association Research Foundation (AWWARF) initiated a study to determine the contribution of waterborne radon to radon levels in indoor household air

  14. An Alpha spectrometer for measuring radon daughter individual activity concentration; Spettrometro Alfa per la misura delle concentrazioni individuali in attivita' della progenie del radon

    Energy Technology Data Exchange (ETDEWEB)

    Berico, M.; Formignani, M. [ENEA, Div. Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche E. Clementel, Bologna (Italy); Mariotti, F. [Bologna Univ., Bologna (Italy). Dipt. di Fisica

    2001-07-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of {sup 218}Po, {sup 214}Pb and {sup 214}Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated. [Italian] Presso l'Istituto per la Radioprotezione, nell'ambito del programma di valutazione di dose da radon e' stato progettato e realizzato uno spettrometro alfa per il monitoraggio continuo in aria (CAM) della progenie del radon e del toron. Le caratteristiche costruttive dello strumento permettono, tramite l'utilizzo di batterie a diffusione a reti, di determinare l'attivita' individuale della progenie per diverse dimensioni granulometriche in particolare per la frazione attaccata e non al particolato amosferico con un taglio granulometrico di qualche nanometro. E' stato inoltre applicato un metodo spettrometrico a tre conteggi per il calcolo delle concentrazioni individuali della progenie del radon, {sup 218}Po, {sup 214}Pb and {sup 214}Bi, effettuando un conteggio alfa di {sup 218}Po e due conteggi alfa di {sup 214}Po. Tale informazione consentira' una valutazione della dose di radon utilizzando il modello dosimetrico in alternativa a quello epidemiologico.

  15. Effectiveness of radon control techniques in fifteen homes

    International Nuclear Information System (INIS)

    Turk, B.H.; Prill, R.J.; Fisk, W.J.; Grimsrud, D.T.; Sextro, R.G.

    1991-01-01

    Radon control systems were installed and evaluated in fourteen homes in the Spokane River Valley/Rathdrum Prairie and in one home in Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurization was always more effective in these houses than SSV by depressurization in reducing indoor radon levels to below guidelines. Basement overpressurization was successfully applied in five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace isolation in reducing radon entry from the crawlspace, but had to be used in conjunction with other mitigation techniques, from the crawlspace, but had to be used in conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations in two houses with air-to-air heat exchangers (AAHX) were reduced to levels inversely dependent on the new total ventilation rates and were lowered even further in one house where the air distribution system was modified. Sealing penetrations in the below-grade surfaces of substructures was relatively ineffective in controlling radon. Operation of the radon control systems (except for the AAHX's) made no measurable change in ventilation rates or indoor concentrations of other measured pollutants. Installation costs ranged from approximately $4/m 2 for sealing to $28/m 2 for the AAHXs. Annual operating costs for the active systems were estimated to be approximately $60 to $170

  16. Detailed analysis of radon flux studies at Australian uranium projects

    International Nuclear Information System (INIS)

    Mudd, Gavin M.

    2005-01-01

    The release of radon gas and radon progeny from uranium projects is a major issue during operation as well as for the design of rehabilitation works. In Australia, there have been a number of premining radon flux studies as part of the environmental investigation and potential development of recent uranium projects. There is also an increasing amount of operational data on radon fluxes and loads from various aspects of projects, such as tailings, waste rock and mills. Thus there exists much useful measured data which can be used to assess the design radon flux and load targets for rehabilitation. The main projects for which radon data exists includes Ranger, Olympic Dam, Beverley, Honeymoon, Jabiluka, Yeelirrie, Lake Way, Koongarra, Moline, Coronation Hill, Rockhole, Nabarlek, Rum Jungle, Port Pirie and Ben Lomond. To date, much of this data has not been systematically evaluated. The need to compile and assess this data is twofold. Firstly, to assess the loads released from uranium production as an input into life-cycle analyses of the nuclear fuel cycle, such as those undertaken by UNSCEAR and industry groups. Secondly, there is a need to set suitable design standards for radon flux for the rehabilitation of former and current uranium projects. This paper will present such a detailed compilation of radon fluxes and loads which can then be used as the basis for both life-cycle analyses as well as setting appropriate site-specific rehabilitation criteria for radon. The implications for former and current projects is then discussed as well as future data needs. Ultimately, there is a critical need for thorough baseline surveys prior to mining to ensure accurate assessments of changes to radon fluxes and loads. The data and analysis presented is considered applicable to all uranium projects in Australia, as well as being a useful model for considering such issues internationally

  17. Radon in Croatian spas

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Planinic, J.

    2004-01-01

    There are ten thermal spas in Croatia and all of them provide health services for patients and visitors. Radon measurements were performed since there is a lack of data concerning natural radioactivity originated from radon and its short-lived progenies in such environments. The thermal water at two different sites (the indoor swimming pool with geothermal water and the spring) in each spa was sampled and radon concentrations were measured by AlphaGUARD radon measuring system. The obtained values were in the range of 0.7 to 19 Bq.dm -3 and 2 to 94 Bq.dm -3 for indoor swimming pools and springs, respectively. Integrated measurements of radon concentration in air were performed by two solid state nuclear track detectors LR-115 II (open and diffusion one) thus enabling estimation of equilibrium factor between radon and its daughters. The annual effective doses received by spa workers were found to be about 1 mSv/y (below the lower limit value of 3 mSv/y recommended by ICRP 65). The doses of patients and visitors were one or two order of magnitude lower than that of the personnel. (author)

  18. Lung cancer risk from radon and smoking - additive or multiplicative effect?

    International Nuclear Information System (INIS)

    Tomasek, L.

    2016-01-01

    The aim of the work is to evaluate the risk of lung cancer when combined radon and smoking exposure. Methodologically the evaluation is based on case and control study nested in two cohort studies, including 11,000 miners and 12,000 residents exposed to high concentrations of radon in homes. Radon exposure in individuals is complemented by information on smoking gained personally from them or from their relatives. The study is based on 1,073 cases of lung cancer among miners and 372 cases in population study. Control subjects were randomly selected in each study based on gender, year of birth and age achieved. The combined effect of smoking and radon is evaluated using the so-called geometric mixed models, whose special case is an additive or multiplicative model. The resulting model of the risk is closer to additive interaction (parameter of mixed model 0.2). The consequences of the model in the study of population are illustrated by estimates of lifetime risk in a hypothetical population of smokers and nonsmokers. Compared to the multiplicative risk model, the lifetime risk significantly increased according to the best geometric mixed model, especially in the population of non-smokers. (author)

  19. Chemical properties of radon

    International Nuclear Information System (INIS)

    Stein, L.

    1986-01-01

    Radon is frequently regarded as a totally inert element. It is, however, a ''metalloid'' - an element which lies on the diagonal of the Periodic Table between the true metals and nonmetals and which exhibits some of the characteristics of both. It reacts with fluorine, halogen fluorides, dioxygenyl salts, fluoro-nitrogen salts, and halogen fluoride-metal fluoride complexes to form ionic compounds. Several of the solid reagents can be used to collect radon from air but must be protected from moisture, since they hydrolyze readily. Recently, solutions of nonvolatile, cationic radon have been produced in nonaqueous solvents. Ion-exchange studies have shown that the radon can be quantitatively collected on columns packed with either Nafion resins or complex salts. In its ionic state, radon is able to displace H + , Na + , K + , Cs + , Ca 2+ , and Ba 2+ ions from a number of solid materials. 27 refs., 6 figs

  20. Analysis of infiltration through a clay radon barrier at an UMTRA disposal cell

    International Nuclear Information System (INIS)

    1991-01-01

    An infiltration study was initiated in January 1988 to assess the percent saturation in, and infiltration through, clay radon barriers of typical Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cells. Predicting infiltration through the radon barrier is necessary to evaluate whether the disposal cell will comply with the proposed US Environmental Protection Agency (EPA) groundwater protection standards (40 CFR 192). The groundwater standards require demonstrating that tailings seepage will not cause background concentrations or maximum concentration limits (MCLs) to be exceeded at the downgradient edge of the disposal facility (the point of compliance, or POC). This demonstration generally consists of incorporating the predicted seepage flux and the concentration of the specific hazardous constituents into a contaminant transport model, and predicting the resultant concentrations at the POC. The infiltration study consisted of a field investigation to evaluate moisture conditions in the radon barrier of the completed Shiprock, New Mexico, UMTRA Project disposal cell and previously completed UMTRA Project disposal cells at Clive, Utah, and Burrell, Pennsylvania. Coring was conducted to measure percent saturation profiles in the radon barriers at these disposal cells. In addition, a detailed investigation of the Shiprock radon barrier was conducted to establish the effects of meteorological stresses on moisture conditions in the filter layer and radon barrier. The Shiprock infiltration study was also intended to characterize hydraulic gradients and operational unsaturated hydraulic conductivities in the radon barrier

  1. Residential Radon Exposure and Incidence of Childhood Lymphoma in Texas, 1995–2011

    Directory of Open Access Journals (Sweden)

    Erin C. Peckham

    2015-09-01

    Full Text Available There is warranted interest in assessing the association between residential radon exposure and the risk of childhood cancer. We sought to evaluate the association between residential radon exposure and the incidence of childhood lymphoma in Texas. The Texas Cancer Registry (n = 2147 provided case information for the period 1995–2011. Denominator data were obtained from the United States Census. Regional arithmetic mean radon concentrations were obtained from the Texas Indoor Radon Survey and linked to residence at diagnosis. Exposure was assessed categorically: ≤25th percentile (reference, >25th to ≤50th percentile, >50th to ≤75th percentile, and >75th percentile. Negative binomial regression generated adjusted incidence rate ratios (aIRR and 95% confidence intervals (CI. We evaluated lymphoma overall and by subtype: Hodgkin (HL; n = 1248, Non-Hodgkin excluding Burkitt (non-BL NHL; n = 658, Burkitt (BL; n = 241, and Diffuse Large B-cell (DLBCL; n = 315. There was no evidence that residential radon exposure was positively associated with lymphoma overall, HL, or BL. Areas with radon concentrations >75th percentile had a marginal increase in DLBCL incidence (aIRR = 1.73, 95% CI: 1.03–2.91. In one of the largest studies of residential radon exposure and the incidence of childhood lymphoma, we found little evidence to suggest a positive or negative association; an observation consistent with previous studies.

  2. Radon dose and aerosols

    International Nuclear Information System (INIS)

    Planinic, J.; Radolic, V.; Faj, Z.; Vukovic, B.

    2000-01-01

    The equilibrium factor value (F) was measured in the NRPB radon chamber and the corresponding track density ratio (r = D/D 0 ) of bare (D) and diffusion (D 0 ) LR-115 nuclear track detectors was determined, as well as the regression equation F(r). Experiments with LR-115 nuclear track detectors and aerosol sources (burning candle and cigarette) were carried out in the Osijek University radon chamber and afterwards an empirical relationship between the equilibrium factor and aerosol concentration was derived. For the purpose of radon dose equivalent assessment, procedures for determining the unattached fraction of radon progeny were introduced using two nuclear track detectors. (author)

  3. Radon remediation of a two-storey UK dwelling by active sub-slab depressurization: observations on hourly Radon concentration variations

    International Nuclear Information System (INIS)

    Denman, A.R.

    2008-01-01

    Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored at hourly intervals throughout a 5-week period during which sub-slab depressurization remediation measures, including an active sump system, were installed. Remediation of the property was accomplished successfully, with the mean radon levels upstairs and downstairs greatly reduced and the prominent diurnal variability in radon levels present prior to remediation almost completely removed. Following remediation, upstairs and downstairs radon concentrations were 32% and 16% of their pre-remediation values respectively. The mean downstairs radon concentration was lower than that upstairs, with pre-and post-remediation values of the upstairs/downstairs concentration ratio, R U/D , of 0.93 and 1.76 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 hour or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure-difference prior to remediation. This correlation disappears following remediation, confirming the effectiveness of the remediation procedure in mitigating radon ingress from the ground via the stack-effect. Overall, these observations provide further evidence that radon emanation from building materials makes a not insignificant contribution to radon concentration levels within the building. Furthermore, since this component remains essentially unaffected by sub-slab depressurization, its proportional contribution to the total radon levels in the home increases following remediation, leading to the conclusion that where

  4. Surface-water radon-222 distribution along the west-central Florida shelf

    Science.gov (United States)

    Smith, C.G.; Robbins, L.L.

    2012-01-01

    In February 2009 and August 2009, the spatial distribution of radon-222 in surface water was mapped along the west-central Florida shelf as collaboration between the Response of Florida Shelf Ecosystems to Climate Change project and a U.S. Geological Survey Mendenhall Research Fellowship project. This report summarizes the surface distribution of radon-222 from two cruises and evaluates potential physical controls on radon-222 fluxes. Radon-222 is an inert gas produced overwhelmingly in sediment and has a short half-life of 3.8 days; activities in surface water ranged between 30 and 170 becquerels per cubic meter. Overall, radon-222 activities were enriched in nearshore surface waters relative to offshore waters. Dilution in offshore waters is expected to be the cause of the low offshore activities. While thermal stratification of the water column during the August survey may explain higher radon-222 activities relative to the February survey, radon-222 activity and integrated surface-water inventories decreased exponentially from the shoreline during both cruises. By estimating radon-222 evasion by wind from nearby buoy data and accounting for internal production from dissolved radium-226, its radiogenic long-lived parent, a simple one-dimensional model was implemented to determine the role that offshore mixing, benthic influx, and decay have on the distribution of excess radon-222 inventories along the west Florida shelf. For multiple statistically based boundary condition scenarios (first quartile, median, third quartile, and maximum radon-222 inshore of 5 kilometers), the cross-shelf mixing rates and average nearshore submarine groundwater discharge (SGD) rates varied from 100.38 to 10-3.4 square kilometers per day and 0.00 to 1.70 centimeters per day, respectively. This dataset and modeling provide the first attempt to assess cross-shelf mixing and SGD on such a large spatial scale. Such estimates help scale up SGD rates that are often made at 1- to 10-meter

  5. Contribution of radon in natural gas to the dose from aiborne radon-daughters in homes

    International Nuclear Information System (INIS)

    Barton, C.J.; Moore, R.E.; Rohwer, P.S.

    1973-01-01

    Data have been obtained on the radon concentration in natural gas supplied to several metropolitan areas in the United States. The average value of 20 pCi/l was selected to estimate the contribution of this source of natural radioactivity to doses from radon-daughters received by individuals in homes. Radon-daughter concentrations in the home atmosphere were calculated by use of computer programs for an 8000 ft 3 house in which 27 ft 3 of gas per day was used for cooking in an unvented kitchen range. The total estimated dose to the bronchial epithelium included contributions from radon plus daughters in the outside ventilation air, each of which was assumed to be present at a concentration of 0.13 pCi/l, and from the radon plus daughters in the natural gas. The latter contribution averaged approximately 3 percent of the total dose. There was a 3.5 percent decrease in the estimated total dose when the air change rate increased from 0.25 to 2.0 per hour. We conclude that radon and radon-daughters entering the home with natural gas produce a negligible fraction of the total dose to the respiratory system of home occupants from airborne radon-daughters

  6. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    Energy Technology Data Exchange (ETDEWEB)

    Momeni, M H; Lindstrom, J B; Dungey, C E; Kisieleski, W E

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m/sup 3/ on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m/sup 3/. Average working-level background is 3.6 x 10/sup -3/.

  7. An investigation into the knowledge and attitudes towards radon testing among residents in a high radon area

    International Nuclear Information System (INIS)

    Clifford, Susan; Menezes, Gerard; Hevey, David

    2012-01-01

    The aim of this study was to investigate the knowledge and attitudes of residents in the Castleisland area to radon. Castleisland in Co. Kerry was described as a high radon area following the discovery of a house in the area with radon levels 245 times that of the national reference level. Residents in this area were then asked to measure their homes for radon in the Castleisland radon survey. The uptake of this measurement was 17%. In order to investigate this response rate further, a questionnaire was designed and distributed to residents in the Castleisland area. This questionnaire measured the testing history of the participants, the reasons for testing/not testing, the factors important to them when considering having their home tested, radon knowledge and finally intentions to measure their home for radon. It was found that the main reason people do not test their home for radon is that they believe their home does not have a problem. Optimistic bias was thought to play a role here. The subjective norm component of the theory of planned behaviour was found to have a significant independent contribution in the variation in intentions to measure one’s home for radon and this in turn could be targeted to increase uptake of radon measurement in the future. (note)

  8. Radon in dwellings the national radon survey Clare, Limerick and Tipperary

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.; O'Colmain, M.

    1998-12-01

    This report presents the results of the fourth phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Clare, Limerick and Tipperary. The average radon concentrations for the houses measured in these counties were 88 Bq/m 3 , 77 Bq/m 3 and 79 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  9. Environmental Concentration of Radon and Radon Progeny in a Nuclear Facility in a Decommissioning Stage

    International Nuclear Information System (INIS)

    Ramirez, M. P.; Correa, E.; Sancho, C.

    1999-01-01

    According to the new European Directive 96/29/EURATOM the radiological risk due to natural radionuclides must be consider and the pertinent periodic control must be realized. During the works performed at CIEMAT an estimation of the effective average doses due to Radon inhalation in work places of the installation have been performed. Radon and Radon progeny concentration has been measured in continuous joint whit the meteorological conditions as temperature, pressure and relative humidity. Two different equipment has been used: Alpha-guard whit ionization chamber detector and Eda-wlm-300 whit a semiconductor detector. A passive Radon detector, E-perm has been simultaneously used in the monitoring system. The results obtained during the measuring of Radon and Radon progeny concentrations indoors and estimation of doses have been analyzed and are presented in the paper. (Author) 11 refs

  10. Pilot study of the application of Tellus airborne radiometric and soil geochemical data for radon mapping

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D. [British Geological Survey, Kingsley Dunham Centre, Keyworth, Nottingham NG12 5GG (United Kingdom)], E-mail: jda@bgs.ac.uk; Miles, J.C.H.; Green, B.M.R. [Health Protection Agency (HPA) - Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Larmour, R. [Environment and Heritage Service, Department of the Environment, Belfast BT7 2JA (United Kingdom)

    2008-10-15

    The scope for using Tellus Project airborne gamma-ray spectrometer and soil geochemical data to predict the probability of houses in Northern Ireland having high indoor radon concentrations is evaluated, in a pilot study in the southeast of the province, by comparing these data statistically with in-house radon measurements. There is generally good agreement between radon maps modelled from the airborne radiometric and soil geochemical data using multivariate linear regression analysis and conventional radon maps which depend solely on geological and indoor radon data. The radon maps based on the Tellus Project data identify some additional areas where the radon risk appears to be relatively high compared with the conventional radon maps. One of the ways of validating radon maps modelled on the Tellus Project data will be to carry out additional indoor measurements in these areas.

  11. Radon mitigation in schools utilising heating, ventilating and air conditioning systems

    International Nuclear Information System (INIS)

    Fisher, G.; Ligman, B.; Brennan, T.; Shaughnessy, R.; Turk, B.H.; Snead, B.

    1994-01-01

    As part of a continuing radon in schools technology development effort, EPA's School Evaluation Team has performed radon mitigation in schools by the method of ventilation/pressurisation control technology. Ventilation rates were increased, at a minimum, to meet the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) standard, Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1989). This paper presents the results and the preliminary evaluations which led to the team's decision to implement this technology. Factors considered include energy penalties, comfort, indoor air quality (IAQ), building shell tightness, and equipment costs. Cost benefit of heat recovery ventilation was also considered. Earlier results of the SEP team's efforts have indicated a severe ventilation problem within the schools of the United States. Two case studies are presented where HVAC technology was implemented for controlling radon concentrations. One involved the installation of a heat recovery ventilator to depressurise a crawl space and provide ventilation to the classrooms which previously had no mechanical ventilation. The other involved the restoration of a variable air volume system in a two-storey building. The HVAC system's controls were restored and modified to provide a constant building pressure differential to control the entry of radon. Pre-mitigation and post-mitigation indoor air pollutant measurements were taken, including radon, carbon dioxide (CO 2 ), particulates, and bio-aerosols. Long-term monitoring of radon, CO 2 , building pressure differentials, and indoor/outdoor temperature and relative humidity is presented. (author)

  12. Logistic regression model for detecting radon prone areas in Ireland.

    Science.gov (United States)

    Elío, J; Crowley, Q; Scanlon, R; Hodgson, J; Long, S

    2017-12-01

    A new high spatial resolution radon risk map of Ireland has been developed, based on a combination of indoor radon measurements (n=31,910) and relevant geological information (i.e. Bedrock Geology, Quaternary Geology, soil permeability and aquifer type). Logistic regression was used to predict the probability of having an indoor radon concentration above the national reference level of 200Bqm -3 in Ireland. The four geological datasets evaluated were found to be statistically significant, and, based on combinations of these four variables, the predicted probabilities ranged from 0.57% to 75.5%. Results show that the Republic of Ireland may be divided in three main radon risk categories: High (HR), Medium (MR) and Low (LR). The probability of having an indoor radon concentration above 200Bqm -3 in each area was found to be 19%, 8% and 3%; respectively. In the Republic of Ireland, the population affected by radon concentrations above 200Bqm -3 is estimated at ca. 460k (about 10% of the total population). Of these, 57% (265k), 35% (160k) and 8% (35k) are in High, Medium and Low Risk Areas, respectively. Our results provide a high spatial resolution utility which permit customised radon-awareness information to be targeted at specific geographic areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Radon risk communication research: Practical lessons

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. There are now a number of completed studies that have examined how well alternative ways of communicating about radon risk have accomplished the goals of motivating appropriate testing and mitigation. This paper summarizes the research results that are most crucial for planning and implementing effective radon risk communication programs. We identify six reasons why people do not respond to radon as a serious threat and provide some remedies suggested by radon studies

  14. Radon classification of building ground

    International Nuclear Information System (INIS)

    Slunga, E.

    1988-01-01

    The Laboratories of Building Technology and Soil Mechanics and Foundation Engineering at the Helsinki University of Technology in cooperation with The Ministry of the Environment have proposed a radon classification for building ground. The proposed classification is based on the radon concentration in soil pores and on the permeability of the foundation soil. The classification includes four radon classes: negligible, normal, high and very high. Depending on the radon class the radon-technical solution for structures is chosen. It is proposed that the classification be done in general terms in connection with the site investigations for the planning of land use and in more detail in connection with the site investigations for an individual house. (author)

  15. The radon issue: Considerations on regulatory approaches and exposure evaluations on the basis of recent epidemiological results

    International Nuclear Information System (INIS)

    Bochicchio, Francesco

    2008-01-01

    Recent epidemiological results have shown consistent statistically significant increases of lung cancer risk due to exposure to radon in dwellings at moderate levels of exposure, and a strong synergism with cigarette smoking. These results are summarized and discussed in relation to their possible implications for the regulatory control of radon and for future policies for the control of radon risk

  16. Application of soil radon survey to searching for sandstone-type uranium deposit at western margin of Ordos basin

    International Nuclear Information System (INIS)

    Liu Hanbin; Yin Jinshuang; Cui Yonghui

    2006-01-01

    On the basis of condition tests of soil radon survey at certain uranium deposit in Ordos basin, regional soil radon survey was carried but in a study area of western margin of Ordos basin. By processing of soil radon survey data, five anomalous areas with certain metallogenic potential have been delineated. Then, discovered anomalies have been interpreted and evaluated for providing important reference for further drilling work. Research results indicate that by soil radon survey, anomalies may be distinguished in a basin, and soil radon survey could be an important geochemical prospecting method for rapid evaluation of sandstone-type uranium deposit in basin areas. (authors)

  17. Investigation of radon level in Chongqing

    International Nuclear Information System (INIS)

    Pan Chunzhen; Liu Jialie; Du Hengyan; Wang Ling; Li Yiwei

    2009-01-01

    Contents of radon in air in the urban district, building fields,diggings and hotel in Chongqing were investigated. Result shows that the mean concentration of radon is 10.8 Bq/m 3 in air in the urban district, and the mean concentration of radon is 1193 Bq/m 3 in soils on building fields. Radon level is obviously different in each of diggings, with the highest being in fluorite mine and the second in plumbum and zinc mine. The statistical mean value of radon concentration of 10 typles of diggings investigated is 65.2 Bq/m 3 , while the mean concentration of radon in fluorite mine is 369 Bq/m 3 , which is 35 times higher than in the urban area. The mean concentration of radon is 32.9 Bq/m 3 in eight hotels. (authors)

  18. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    International Nuclear Information System (INIS)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V.

    2003-01-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO 2 ). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer, a

  19. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    Energy Technology Data Exchange (ETDEWEB)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V

    2003-07-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO{sub 2}). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer

  20. Radon Concentration in Caves of Croatia - Assesing Effective Radon Doses for Occupational Workers and Visitors

    International Nuclear Information System (INIS)

    Radolic, V.; Miklavcic, I.; Poje, M.; Stanic, D.; Vukovic, B.; Paar, D.

    2011-01-01

    Radon monitoring at potentially highly radioactive location such as caves is important to assess the radiological hazards to occupational workers and occasional visitors. In its Publication 65 the ICRP has produced recommendations dealing with exposure to elevated background radiation, in particular, the risk associated with the inhalation of radon and radon progeny. Recommended annual effective dose from radon 222Rn and its short-lived progeny for workers should not exceed 20 mSv and for occasional users (visitors) the same recommendation is 1 mSv. Measurements were performed with series of track etched detectors (LR115 - type II) in several caves in Croatia. The obtained values for the radon concentration ranged from ambient values up to several thousand Bq m -3 . Radon concentration was measured in about 20 caves of Velebit and Zumberak mountains and the highest radon concentration was in Lubuska jama (3.8 kBq m -3 ) and cave Dolaca (21.8 kBq m -3 ), respectively. Djurovica cave is especially interesting because of its huge tourist potential due to its location bellow Dubrovnik airport. Its mean annual radon concentration of 17.6 kBq m -3 classifies Djurovica cave among caves with high radon concentration. A visitor during half an hour visit at summer time would receive an effective dose of 30.6 μSv. Calculated mean dose rate of 44 μSv/h means that workers (mainly tourist guides) should limit their time inside cave to 454 hours per year. Manita pec is the only cave open for tourists on the territory of Paklenica National Park. The preliminary radon measurements performed during summer 2010, gave an average radon concentration of 1.1 kBq m -3 . An exposure to average dose rate of 3.7 μSv/h means that the tourist guides would receive an effective dose of 0.42 mSv during summer period according to their working schedule. A visitor during half an hour visits would receive an effective dose of 1.86 μSv. (author)

  1. Cost effectiveness of reducing radon exposure in Spanish dwellings

    International Nuclear Information System (INIS)

    Colgan, P.A.; Gutierrez, J.

    1996-01-01

    Published information on the distribution of radon levels in Spanish single family dwellings is used to evaluate the cost-effectiveness of three different intervention scenarios: remediation of existing dwellings, radon proofing of all future dwellings and the targetting of areas with higher than average indoor radon concentrations. Analysis is carried out on the basis of a Reference Level of 400 Bq m -3 for the existing housing stock and 200 Bq m -3 for new dwellings. Certain assumptions are made about the effectiveness and durability of the measures applied and annualised costs are used to calculate the costs per lung cancer death averted. The results reveal that targetting future housing is a more cost-effective option than remediation of existing dwellings with radon concentrations above the Reference Level -the costs per lung cancer death averted are typically $145000. In high-risk areas, these costs can be considerably less, depending on the percentage of dwellings expected to exceed the Reference Level and the average savings in exposure as a result of the intervention. The costs of intervention to reduce lung cancer deaths following exposure to radon compare favourably with those of other health programmes in other countries. (Author)

  2. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  3. Radon emanometry in active volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, J.L.; Monnin, M. (CNRS, IN2P3, BP45/F63170 Aubiere (France)); Cejudo, J. (Instituto Nacional de Investigaciones Nucleares, Mexico City)

    1984-01-01

    Radon emission measurements from active volcanoes has, since 1981, been continuously measured at monitoring stations in Mexico and in Costa Rica. Counting of etched alpha tracks on cellulose nitrate LR-115 detectors give varying results at the several stations. Radon emanation at Chichon, where an explosive eruption occurred in 1982, fell down. Radon detection at the active volcano in Colima shows a pattern of very low emission. At the Costa Rica stations located at Poas, Arenal and Irazu, the radon emanation shows regularity.

  4. Radon risk in residential buildings

    International Nuclear Information System (INIS)

    Niewiadomski, T.

    1996-01-01

    The author discusses the risk related to the inhalation of radon decay products. This products are the cause of almost the half of the doses absorbed by the people. The concentration of radon in buildings is much higher than in the open areas and its country average in Poland is 50 Bq/m 3 . It is difficult to predict the concentration of radon in the building without measurement. Author concludes that there are technical means to decrease radon concentration in buildings

  5. Mapping of residential radon in the world

    International Nuclear Information System (INIS)

    Zielinskia, Jan M.; Chambers, Douglas B.

    2008-01-01

    We have created a database of national radon levels around the world building on initial information from the surveys conducted by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) from 2001 through 2007 for its 2006 Annex E on radon. We have conducted a systematic review of all original documents contributing information to the database, and of have collected all other relevant documents to enhance this database. Among the sources of data, in addition to the recent UNSCEAR surveys, the UNSCEAR 2000 Report, and 'An overview of radon surveys in Europe', the following sources were searched for keywords (indoor and radon): Medline, tables of content of Radiation Protection Dosimetry, tables of content of Radiation Measurements, and the Web. Initially for the purpose of data quality objectives (DQO) we used following valuation order to classify the reliability of the references: journal publication, conference proceedings, internal report, UNSCEAR Surveys, Who 2006 Survey, Personal communication. However, we realized that for the purpose of assessing the reliability of the national indoor radon levels the above classification did not work well given that most of the information had been published in 'gray literature' and that some of this literature was of very high quality. Therefore we treated journal publications, conference proceedings, and internal reports equally as long as they were publicly and relatively easily available (on the web for example). We evaluated each reference in terms of level of evidence for using national Average Radon Level reported in the reference (sufficient evidence, limited evidence, and inadequate evidence). Currently the database contains information on national indoor levels from 67 countries (out of 193 recognized by Who). These 67 countries represent 76% of the world's population and 71% of its land mass. Radon information varies by continent with only three African countries (out of 53) and 34

  6. An investigation of radon mitigation in Pennsylvania

    International Nuclear Information System (INIS)

    Belanger, W.E.

    1990-01-01

    This paper reports that Radon mitigation contractors were contacted to obtain information on the progress of radon mitigation in Pennsylvania. Information was obtained on the beginning and ending radon concentrations, the cost of the job, the mitigation method used, and the location by zip code. Most radon mitigations achieved reductions below 90 percent, and most achieved 4 pCi/1. 65 percent achieved 2 pCi/1. There was little relationship between the cost of the job and either the percent reduction or the beginning radon. Percent reduction was strongly related to beginning radon, with lower percent reductions associated with low starting radon

  7. Episodic radon changes in subsurface soil gas along active faults and possible relation to earthquakes

    International Nuclear Information System (INIS)

    King, C.

    1980-01-01

    Subsurface soil gas along active faults in central California has been continuously monitored by the Track Etch method to test whether its radon-isotope content may show any premonitory changes useful for earthquake prediction. The monitoring network was installed in May 1975 and has since been gradually expanded to consist of more than 60 stations along a 380-km section of the San Andreas fault system between Santa Rosa and Cholame. This network has recorded several episodes, each lasting several weeks to several months, during which the radon concentration increased by a factor of approximately 2 above average along some long, but limited, fault segments (approx.100 km). These episodes occurred in different seasons and do not appear to be systematically related to changes in meteorological conditions. However, they coincided reasonably well in time and space with larger local earthquakes above a threshold magnitude of about 4.0. These episodic radon changes may be caused by a changing outgassing rate in the fault zones in response to some episodic strain changes, which incidentally caused the earthquakes

  8. Effect of natural ventilation on radon and radon progeny levels in houses. Rept. for Apr 90-Sep 91

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1991-01-01

    The paper discusses the effect of natural ventilation on radon and radon progeny levels in houses. Contradicting the widely held assumption that ventilation is ineffective in reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5 to 10 using only natural ventilation. Measurement of the outdoor-basement pressure differential and the radon entry rate shows that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes: (1) the obvious one, dilution, which lowers radon concentrations by adding uncontaminated outdoor air; and (2) although less evident, introducing a pressure break in the system through an open basement window which, in turn, reduces the outdoor-basement pressure differential and the rate at which radon-laden soil gas is drawn into the house. The radon entry rate was found to be a linear function of basement depressurization up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubled the building air exchange rate and reduced the radon entry rate by up to a factor of 5

  9. Navy Radon Assessment and Mitigation Program: Work/quality assurance project plan screening phase

    International Nuclear Information System (INIS)

    1991-03-01

    In 1987, the military services of the United States were tasked to take appropriate action to establish an indoor radon assessment and mitigation program. As a result, the Naval Facilities Engineering Command (NAVFACENGCOM) was assigned the responsibility of identifying potential hazards to personnel from exposure to naturally occurring radon gas and prioritizing corrective actions and to coordinating these actions with the major claimants. NAVRAMP is based upon current US Environmental Protection Agency (EPA) guidelines. The program has been separated into four phases. The screening phase will concentrate on evaluating radon levels, based on statistical samples, in those buildings that have been determined to be at most at risk to elevated levels of radon, such as base housing, schools, day-care centers, hospitals, brigs, Base Officer Quarters, and Base Enlisted Quarters. During the assessment phase, every building that contains personnel for over 4 h/day will be evaluated. Mitigation work will be accomplished by Navy or Navy-contracted personnel. HAZWRAP services during the mitigation phase will consist of determining the extent of reduction in radon levels after the mitigation effort. 7 refs., 11 figs

  10. Radon measurements in underground and ground constructions in Tashkent city

    International Nuclear Information System (INIS)

    Akimov, V.A.; Yafasov, A.Y.; Vasidov, A.; En, Z.; Tillaev, T.; Tsipin, V.Z.

    2002-01-01

    More than half of the dose of the natural radioactivity received by population is related to radon and its progeny. Investigations of scientists all over the world have shown that excessive radon and its progeny exposure dose is associated with a risk of lung cancer. Short-lived radon daughters (Po-218 and Po-214) are considered to be of the most dangers. At a relaxation process resulting from an earthquake, the radon gas can release from the accumulators and get indoors, that enhances greatly the radon level there. According to seismologists data, as a result of the strong Tashkent earthquake in 1966, extensive breaks and faults have been formed along the city and its neighborhoods. The aim of our work was evaluation of radon concentration level and its variation in Tashkent subway stations and related underground offices and also in apartments of multi story buildings and detached houses. The measurements were conducted by two different techniques-with ionization chamber radiometer 'Alpha GUARD' and with solid state nuclear track detectors. The Alpha GUARD radiometer operates either in the mode of passive sampling, or by pumping air through the ionization camera being of 0.6 l in volume. The radiometer is capable of measuring a volumetric activity of radon-222 in air (Bq/m3), and it is equipped with the devices that measure some environmental parameters such as temperature, relative humidity and air pressure. The range of V A of 222 Rn in air the device is able to measure is 10 to 2x10 6 Bq/m 3 , sensitivity is 1 pulse/min for 20 Bq/m 3 , and its self-background is less than 1 Bq/m 3 . The radon measurements in Tashkent subway stations and underground offices have shown that daily mean radon values were in the range of 14-65 Bq/m 3 , except for the Pushkin Station, where the daily mean V A was 137 Bq/m3. Such a high radon level is connected with availability near the station of one of the numerous faults and fractures of the terrestrial crust responsible for the

  11. A perspective on risks from radon

    International Nuclear Information System (INIS)

    Higson, D. J.

    2010-10-01

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m -3 . The recommended level for workplaces is 1000 Bq m -3 . A risk coefficient of 8 x 10 -10 per Bq h m -3 is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m -3 . Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m -3 . 2) The estimation of risks at levels below 200 Bq m -3 depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  12. A perspective on risks from radon

    International Nuclear Information System (INIS)

    Higson, D.J.

    2011-01-01

    In its Statement on Radon (November 2009), the ICRP has reduced the upper reference level for radon gas in dwellings to 300 Bq m -3 . The recommended level for workplaces is 1000 Bq m -3 . A risk coefficient of 8x10 -10 per Bq h m is recommended without reference to smoking habits. On the basis of these figures,the estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. Also the estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m -3 . Evidence available from other countries shows that: effects on the incidences of lung cancer are uncertain at radon levels below 100 Bq m -3 ; the estimation of risks at levels below 200 Bq m -3 depends on extrapolation from risks observed at higher levels, and risks to non-smokers from radon are 25 times less than risks to smokers. It is concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon.

  13. A perspective on risks from radon

    Energy Technology Data Exchange (ETDEWEB)

    Higson, D. J., E-mail: higsond@bigpond.net.a [Australasian Radiation Protection Society, PO Box 7108, Upper Ferntree Gully, Victoria 3156 (Australia)

    2010-10-15

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m{sup -3}. The recommended level for workplaces is 1000 Bq m{sup -3}. A risk coefficient of 8 x 10{sup -10} per Bq h m{sup -3} is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m{sup -3}. Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m{sup -3}. 2) The estimation of risks at levels below 200 Bq m{sup -3} depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  14. Colloquium:exposure to radon in houses: evaluation and risk management

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    In this article, one intends to develop elements describing the behaviour of radon and its daughters in atmosphere, while pointing out the physical parameters allowing to characterize the personal natural exposure ( alpha potential energy, equilibrium fraction). (N.C.)

  15. Discussion on the source of radon in uranium exploration method using radon-released thermal effect in minerals

    International Nuclear Information System (INIS)

    Su Shoutian.

    1985-01-01

    This paper considers the problem of the source of radon in uranium exploration method using radon-released thermal effect. In minerals by means of scintillation emanometry, we have carried out the measurement on radon content in minerals at various temperature in barren and ore-bearing granites of the granite-type uranium deposit No. 752, and inclusion decrepitation method has also been used to determine the temperature of decrepitation and its relative frequency. It was found from experiments that heated samples may release most of radon prior to inclusion decrepitation, radon released from thermal effect was, on the contrary, very little at temperature intervals of inclusion decrepitation on a large scale basis. When inclusions were ground after radon releasing, it would still release from inclusions after reheating. The radon content calculated from uranium content in inclusions is lower than the sensitivity of the determination method, so it is too difficult to be determined, indicating that the radon content released is not related to inclusions. Samples were determined by uranium chemical analysis and radium radiochemical analysis and it is obvious to note that the radon content released from thermal effect in minerals is positively correlated to the uranium and radium content. Various kinds of experiments suggest that radon is not derived from inclusions but from the whole mineral

  16. Second workshop on radon and radon daughters in urban communities associated with uranium mining and processing

    International Nuclear Information System (INIS)

    1979-01-01

    A second meeting of Atomic Energy Control Board staff, federal and provincial government representatives, and consultants was held to discuss progress in reducing the concentrations of radon and its daughter products in houses in communities like Bancroft, Elliot Lake, Port Hope, and Uranium City. Participants discussed successful and unsuccessful remedial techniques, possible sources of radon, and methods of measuring radon and radon daughters in buildings

  17. Legal issues in radon affairs

    International Nuclear Information System (INIS)

    Massuelle, M.H.

    1999-01-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of experts and the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise

  18. Legal issues in radon affairs

    Energy Technology Data Exchange (ETDEWEB)

    Massuelle, M.H. [Inst. de Protection et de Surete Nucleaire, Fontenay aux Roses (France)

    1999-12-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of expertsand the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise.

  19. Radon permeability of foils measured by SSNTD technique (non-equilibrium approach)

    Energy Technology Data Exchange (ETDEWEB)

    Hakl, J.; Hunyadi, I.; Toth-Szilagyi, M. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete)

    1991-01-01

    Alpha sensitive solid state nuclear track detectors find wide application in the measurement of indoor radon and in field surveys. These detectors are sensitive both to radon and thoron. A separate estimation of concentrations of the two radon isotopes is an everyday problem. One possible way to solve this problem is based on the great difference between the radon and thoron decay constants. This means that thoron can be excluded from the sensitive volume of the radon measuring device by placing a proper gas permeable polymeric membrane over its opening window. The most important parameter determining the suitability of a given membrane for this task is its permeability constant. There are two possible ways to estimate this constant. One is to use long exposure times (>30 days) allowing steady state conditions for the radon concentration to form in the irradiation chamber. The other is to use a more complicated mathematical evaluation. An exact mathematical method has been developed to describe the radon concentration levels inside the irradiation chamber as a function of time. In this case the measurement can be done far from steady-state condition and the required exposure times range from some hours to a few days only. (author).

  20. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  1. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  2. Radon anomalies prior to earthquakes (2). Atmospheric radon anomaly observed before the Hyogoken-Nanbu earthquake

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Tokonami, Shinji; Yasuoka, Yumi; Shinogi, Masaki; Nagahama, Hiroyuki; Omori, Yasutaka; Kawada, Yusuke

    2008-01-01

    Before the 1995 Hyogoken-Nanbu earthquake, various geochemical precursors were observed in the aftershock area: chloride ion concentration, groundwater discharge rate, groundwater radon concentration and so on. Kobe Pharmaceutical University (KPU) is located about 25 km northeast from the epicenter and within the aftershock area. Atmospheric radon concentration had been continuously measured from 1984 at KPU, using a flow-type ionization chamber. The radon concentration data were analyzed using the smoothed residual values which represent the daily minimum of radon concentration with the exclusion of normalized seasonal variation. The radon concentration (smoothed residual values) demonstrated an upward trend about two months before the Hyogoken-Nanbu earthquake. The trend can be well fitted to a log-periodic model related to earthquake fault dynamics. As a result of model fitting, a critical point was calculated to be between 13 and 27 January 1995, which was in good agreement with the occurrence date of earthquake (17 January 1995). The mechanism of radon anomaly before earthquakes is not fully understood. However, it might be possible to detect atmospheric radon anomaly as a precursor before a large earthquake, if (1) the measurement is conducted near the earthquake fault, (2) the monitoring station is located on granite (radon-rich) areas, and (3) the measurement is conducted for more than several years before the earthquake to obtain background data. (author)

  3. Radon at the Mauna Loa Observatory: transport from distant continents

    International Nuclear Information System (INIS)

    Whittlestone, S.; Robinson, E.; Ryan, S.

    1992-01-01

    Continuous measurements of radon have been made at an altitude of 3400m at the Mauna Loa Observatory, Hawaii. Concentrations ranged from about 20 to more than 700mBq m -3 . These were similar to values at remote Macquarie I., some 2000 km south of Australia in the Southern Ocean. At Mauna Loa, the radon concentrations could usually be separated into free tropospheric and island influenced categories on the basis of local meteorological observations. On one occasion a long range transport event from Asia brought relatively high radon concentrations to Mauna Loa and persisted for several days. The Asian origin of this event was supported by wind trajectories. This measurement program demonstrates the value of radon data in evaluating air transport models and the influence of transport from distant continents on baseline atmospheric measurements. (author)

  4. Radon legislation and national guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Aakerblom, G

    1999-07-01

    The International Commission on Radiological Protection (ICRP) and The Council of the European Union have recommended the Member States to take action against radon in homes and at workplaces. Within the EU project European Research into Radon in Construction Concerted Action, ERRICCA, the Topic Group on Legal and Building Code Impact was designated to study the current radon legislation and give advice regarding future enactment of laws and recommendations. On behalf of the Group, a questionnaire on radon legislation was sent out to nearly all European states and a selection of non-European states. Questions were asked regarding reference levels for dwellings, workplaces and drinking water, and about regulations or recommendations for building materials and city planning. All 15 EU Member States, 17 non-EU European countries and 10 non-European countries responded to the questionnaire. Their answers are considered current as of the end of 1998. Most European States and many non-European countries have recommended reference levels for dwellings and workplaces, and some have guidelines for measures against radon incorporated in their building codes and guidelines for construction techniques. However, only a few countries have enforced reference levels or regulations for planning and construction. The reference levels for indoor radon concentration in existing and new dwellings or workplaces are within the range 150-1000 Bq/m{sup 3}. Sweden is the only country (Out of 15 EU member states) which has enforced limits for existing dwellings. Sweden and the UK have both enforced levels for new dwellings. 7 non-European countries (Out of 17 responding countries) have enforced levels for existing dwellings and 9 have them for new dwellings. At the end of 1998, only Finland, Sweden, the Czech Republic, Romania, Russia and the Slovak Republic had limits for radon in water, although 8 countries were planning to introduce such limits. The present limits are within the range for

  5. Radon legislation and national guidelines

    International Nuclear Information System (INIS)

    Aakerblom, G.

    1999-07-01

    The International Commission on Radiological Protection (ICRP) and The Council of the European Union have recommended the Member States to take action against radon in homes and at workplaces. Within the EU project European Research into Radon in Construction Concerted Action, ERRICCA, the Topic Group on Legal and Building Code Impact was designated to study the current radon legislation and give advice regarding future enactment of laws and recommendations. On behalf of the Group, a questionnaire on radon legislation was sent out to nearly all European states and a selection of non-European states. Questions were asked regarding reference levels for dwellings, workplaces and drinking water, and about regulations or recommendations for building materials and city planning. All 15 EU Member States, 17 non-EU European countries and 10 non-European countries responded to the questionnaire. Their answers are considered current as of the end of 1998. Most European States and many non-European countries have recommended reference levels for dwellings and workplaces, and some have guidelines for measures against radon incorporated in their building codes and guidelines for construction techniques. However, only a few countries have enforced reference levels or regulations for planning and construction. The reference levels for indoor radon concentration in existing and new dwellings or workplaces are within the range 150-1000 Bq/m 3 . Sweden is the only country (Out of 15 EU member states) which has enforced limits for existing dwellings. Sweden and the UK have both enforced levels for new dwellings. 7 non-European countries (Out of 17 responding countries) have enforced levels for existing dwellings and 9 have them for new dwellings. At the end of 1998, only Finland, Sweden, the Czech Republic, Romania, Russia and the Slovak Republic had limits for radon in water, although 8 countries were planning to introduce such limits. The present limits are within the range for 50

  6. Radon in Dwellings in the Republic of Kalmykia. Results from the National Radon Survey 2006-2007

    International Nuclear Information System (INIS)

    Aakerblom, Gustav; German, Olga; Soederman, Ann-Louise; Stamat, Ivan; Venkov, Vladimir

    2009-02-01

    The National Radon Survey in the Republic of Kalmykia, Russian Federation during 2006-2007 was carried out in a cooperation project between the Swedish Radiation Protection Authority (SSI) and the Russian Institute of Radiation Hygiene (RIRH). In August 2006 SSI, RIRH, federal and local authorities carried out a field study in Kalmykia when radon daughter measurements (equilibrium equivalent radon concentrations in the air) and gamma radiation measurements were made in 103 buildings. Gamma spectrometry measurements were made at several sites. During the visit the cooperating parties devoted some time to the education of local authorities on radon related issues. During three months in the winter season 2006-2007, long term radon trace measurements were made in 525 randomly chosen dwellings in the Republic of Kalmykia. The radon gas activity varied between 3 and 973 Bq/m 3 , with a mean value of 122 Bq/m 3 . In 19 of a total of 835 measurement points, the radon activity exceeded the maximum permitted value in Russia of 200 Bq/m 3 of EERC. The year-round radon trace measurement were made in 20 houses in Elista, the capital of the Republic of Kalmykia, for comparison with the three-month measurements. The year-round measurements showed some higher values for the radon activity, and a correction factor of 0.85 was applied. Using data on the number of people living in detached houses and apartments, and applying the radon activities measured, the number of new lung cancer cases caused by radon was calculated to be 20 to 40 of the 100 new cases reported annually. The methods of construction of the dwellings in Kalmykia is greatly influenced by the history and culture. Most of them were built after World War II and there are only a few that are newly built because of the poor economic situation and the low population growth rate in the Republic. Most people live in detached houses, one-storied with 3-5 rooms, built directly on the ground or on coquina blocks or on a cast

  7. Remedial measures in Swedish and Norwegian houses - application of radon and radon decay product measurements

    International Nuclear Information System (INIS)

    Just, G.; Philipsborn, H. von; Matolin, M.; Molzahn, D.

    1998-01-01

    Houses and apartments in Sweden and Norway with excessive indoor radon concentrations were studied in detail with a variety of methods, standard and novel ones recently developed. For suitable remediation it is necessary to distinguish soil radon and exhalation from blue (porous) concrete. Our CARBOTEST-S is a simple, sensitive, in-situ method to quantify radon exhalation from existing walls, as well as radon permeability of different protective foils and final quality control of foils applied to existing walls. (orig.) [de

  8. Radon levels in Oslo schools

    International Nuclear Information System (INIS)

    Birovlev, A.

    2004-01-01

    Radon measurements using passive CR-39 detectors have been conducted in all schools in Oslo municipality during winter 2003/2004. Results are presented and discussed in the light of qualitative and quantitative factors, some of which are specific for schools as workplaces. Analysis is conducted with respect to factors relating to building construction type, ventilation principle, age of building, building size etc. The influence of ventilation type on radon levels is studied, and problems of investigations based purely on conventional passive radon detectors are noted. Over-estimation of radon concentration by passive detectors and day-night variations of indoor radon levels in buildings with mechanical ventilation systems are discussed. Several guiding principles for planning similar investigations based on above discussions are outlined. (author)

  9. Radon measurements in hispaniola dwellings

    International Nuclear Information System (INIS)

    Gutierrez, J.; Colgan, P.A.; Cancio, D.

    1996-01-01

    The results of a national radon survey and a number of regional surveys of radon in spanish dwelling are reviewed. The best estimate of the geometric mean of indoor radon concentrations is 41.1. Bq/m -3 and single-family dwellings have been shown to be more at risk than apartments. Results need to be interpreted with some caution due to differences in survey methodologies and measurement procedures. The risks from radon exposure are put in perspective by comparison with other voluntary risks. Finally, although a number of 'high risk' areas have already been identified, it is concluded that implementation of a national programme to reduce radon exposure may await a better definition of the problem extent. (authors). 20 refs., 1 tab

  10. Ion climate and radon concentration

    International Nuclear Information System (INIS)

    Busbarna, L.

    1981-01-01

    Characteristic values of radon concentration in natural ion climate and in open air were compared and the effect of artificially produced negative ion excess on the radon concentration of air was studied. The results show that the radon concentration measurable at the rise of negative ion excess is smaller than that in the case of natural equilibrium. This effect can be utilized lowering the background of the scintillation chambers, thus increasing their sensitivity. The negative ions of the artificial ion climate lower radon concentration in closed space. The question arises whether only the ion climate is responsible for the effects on the organism and on the nervous system or the radon concentration of the air also contributes to them. (author)

  11. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  12. Use of the radon gas as a natural geophysical tracer; Utilizacion del gas radon como un trazador geofisico natural

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Balcazar, M.; Flores R, J.H.; Lopez M, A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2006-07-01

    In this work it is denoted the applications of the radon gas like a natural geophysical radiotracer in the different branches of the Earth Sciences (Geology, geophysics and geochemistry). It importance resides in its employment like one additional tool to register the possible occurrence of seismic events by means of radon anomalies that are presented in land movements (volcanic eruptions and presence of geothermal areas), as well as its potential in environmental works whose purpose is the evaluation of the feather of contamination in the underground water and the porous media for spills of hydrocarbons. The measurement techniques to determine the concentration of radon was carried out by means of Solid Detectors of Nuclear tracks, as well as by Liquid scintillation, Clipperton, Honeywell, AlphaGUARD. The towns where these techniques its were applied were: Mexico City, Estado de Mexico (Toluca, ININ), Jalisco (The Spring), Guerrero coast. (Author)

  13. Radon mapping - Santa Barbara and Ventura counties

    International Nuclear Information System (INIS)

    Churchill, R.

    1997-01-01

    Since 1990, the Department of Conservation''s Division of Mines and Geology (DMG) has provided geologic information and conducted several research projects on geology and radon for the California Department of Health Services (DHS) Radon Program. This article provides a brief overview of radon''s occurrence and impact on human health, and summarizes a recent DMG project for DHS that used geologic, geochemical, and indoor radon measurement data to produce detailed radon potential zone maps for Santa Barbara and Ventura counties

  14. Radon concentration variations between and within buildings of a research institute

    International Nuclear Information System (INIS)

    Antignani, S.; Bochicchio, F.; Ampollini, M.; Venoso, G.; Bruni, B.; Innamorati, S.; Malaguti, L.; Stefano, A.

    2009-01-01

    Radon concentration in indoor air has been measured in many countries in a large number of buildings - mainly in houses but also in apartments and workplaces - mostly as a result of the application of radon policies and regulation requirements. However, few systematic analyses are available on radon concentration variations within buildings and between close buildings, especially as regards workplaces; such variations can have a significant impact on indoor radon exposure evaluation, and ultimately on the assessment of the dose from radon received by workers. Therefore, a project was started in 2006 aimed to study the spatial variation of radon concentration among and within about 40 buildings of the Istituto Superiore di Sanita (ISS), a research institute of public health located in Rome over a small area of less than 1 km 2 . Nuclear track detectors (CR-39) were used to measure radon concentration for two consecutive six-month periods, in more than 700 rooms of the surveyed buildings. The paper describes the project in detail and preliminary results regarding 558 rooms in 29 buildings. Coefficient of variation (CV) was calculated as a measure of relative variation of radon concentration between buildings, between floors, and between rooms on the same floor. The CV between buildings resulted quite high (88%), a lower CV (42%) was found for variation between floors, whereas room-to-room CV on the same floor ranged from 25% at first floor level to 48% at basement level. Floor mean ratios, with ground floor as the reference level, were calculated for each building in order to study the correlation between radon concentration and floor levels. Although no clear trend was observed, the average basement/ground floor ratio of radon concentrations resulted about 2.0, whereas the average sixth floor/ground floor ratio of radon concentrations was 0.5. Some discussion on the potential impact of the results of this study on policies and radon regulations are also included in

  15. Problems and precision of the alpha scintillation radon counting system

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markuu, F.

    1985-01-01

    Variations in efficiency as large as 3% have been found for radon scintillation counting systems in which the photomultiplier tubes are sensitive to the thermoluminescent photons emitted by the scintillator after exposure to light or for which the resolution has deteriorated. The additional standard deviation caused by counting a radon chamber on multiple counting systems has been evaluated and the effect, if present, did not exceed about 0.1%. The chambers have been calibrated for the measurement of radon in air, and the standard deviation was equal to statistical counting error combined with a systematic error of 1.1%. 3 references, 2 figures, 2 tables

  16. Radon as a remedy - radiobiological and medical aspects, risk; Radon als Heilmittel - strahlenbiologische und medizinische Aspekte, Risiko

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, E.R.; Nuernberger, E.; Martignoni, K. [Inst. fuer Strahlenhygiene des Bundesamtes fuer Strahlenschutz, Oberschleissheim/Neuherberg (Germany)

    1995-09-01

    For years there have been controversial discussions about the benefit and risk of radon-balneo-therapy. This is particularly true where the inhalation of radon and its daughter products in curative galleries is concerned. Animal experiments and studies on uranium miners have clearly shown that the exposure with radon and its daughter products is connected with an additional risk for lung cancer. Findings on balneo-therapeutic mechanisms are, at best, incomplete and the topic of controversial discussions in radiobiology. This applies specifically to `hormesis` or `adaptive response`, as indicated in this context. Given the numerous reports of therapeutic results, there appear to be curative effects from radon-balneotherapy for special indications. (orig.) [Deutsch] Nutzen und Risiko der Radon-Balneotherapie werden seit Jahren widerspruechlich diskutiert. Dies gilt insbesondere fuer die Inhalation des Radons und seiner Folgeprodukte in Heilstollen. Tierversuche und Untersuchungen bei Uranbergleuten haben eindeutig gezeigt, dass mit der Exposition durch Radon und seinen Folgeprodukten ein zusaetzliches Lungenkrebsrisiko verbunden ist. Erkenntnisse zum Wirkungsmechanismus der Radon-Balneotherapie liegen allenfalls in Ansaetzen vor und werden in der Strahlenbiologie kontrovers diskutiert. Dies gilt insbesondere fuer die in diesem Zusammenhang angefuehrte `Hormesis` bzw. `Adaptive Response`. Geht man von den zahlreich berichteten therapeutischen Erfahrungen aus, so scheint es Hinweise auf Heileffekte der Radon-Balneotherapie fuer spezielle Indikationen zu geben. (orig.)

  17. Radon mitigation in crawl-space houses in Nashville, Tennessee. Report for October 1987-July 1988

    International Nuclear Information System (INIS)

    Pyle, B.E.; Williamson, A.D.; Fowler, C.S.; Belzer, F.E.; Osborne, M.C.

    1988-05-01

    Approximately 15% of existing U.S. houses are built over dirt crawl spaces, and little or no data exist relative to radon mitigation techniques for this style of house construction. This paper discusses and Environmental Protection Agency radon mitigation demonstration. A variety of techniques were evaluated to determine the most-effective and least-costly method of radon mitigation

  18. Radon and its daughters in vivo

    International Nuclear Information System (INIS)

    Rundo, J.

    1983-01-01

    Some aspects of the behavior of radon and its short-lived daughters in vivo are described and a relationship between the radon exhalation rate and time after a meal is demonstrated. A major but short-lived postprandial increase in the exhalation rate of radon produced from skeletally-deposited radium was observed and a similar effect in exhalation rate of environmental radon by persons containing no radium was noted. Persons living in houses with elevated concentrations of radon may contain sufficient activity for its detection by external gamma-ray counting. Some of the activity observed is due to inhaled daughter-products in the chest, and some to daughter-products associated with and produced by the decay of radon throughout the body. 3 references, 8 figures. (MF)

  19. ERRICCA radon model intercomparison exercise

    DEFF Research Database (Denmark)

    Andersen, C.E.; Albarracín, D.; Csige, I.

    1999-01-01

    -state diffusive radon profiles in dry and wet soils, (2) steady-state entry of soil gas and radon into a house, (3) time-dependent radon exhalation from abuilding-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive......, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommendedthat additional exercises are carried out....

  20. Quantification of the lung cancer risk from radon daughter exposure in dwellings - an epidemiological approach

    International Nuclear Information System (INIS)

    Edling, C.; Wingren, G.; Axelson, O.

    1986-01-01

    Some epidemiological studies have suggested a relationship between the concentration of decay products from radon, i.e., radon daughter exposure, in dwellings and lung cancer. Further experiences made from radon measurements have indicated that both building material and particularly the radioactivity in the ground is of importance for the leakage of radon into the houses. In Sweden, a survey is now ongoing in 15 municipalities with alum shale deposits, and in one area a case-referent evaluation has been made, considering building materials, ground conditions and smoking habits. The size of the study is small, but the results suggest that a risk is at hand and that there is a multiplicative effect from smoking and radon daughter exposure. About 30% of the lung cancers in the studied population might be attributable to elevated and potentially avoidable exposure to radon and radon daughters. (author)

  1. Radon i danske lejeboliger

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Skytte Clausen, Louise

    I denne undersøgelse kortlægges radonindholdet i indeluften og det undersøges, hvordan indholdet af radon i indeluften er fordelt og spredes i en ejendom, og om det er muligt at pege på en bygningsdel eller en bygningskomponent som en spredningsvej for radon i boliger. Boligerne er lejeboliger og...... ligger i etageejendomme, kæde- og rækkehuse tilhørende bygningstyper opført fra 1850 og frem. De udvalgte ejendomme ligger i områder af landet, hvor der ved tidligere undersøgelser har vist sig at være en stor andel af huse med et højt indhold af radon i indeluften. Koncentrationen af radon er målt over...

  2. Radon problem in uranium industry

    International Nuclear Information System (INIS)

    Khan, A.H.; Raghavayya, M.

    1991-01-01

    Radon emission is invariably associated with the mining and processing of uranium ores. Radon (sup(222)Rn) enters mine atmosphere through diffusion from exposed ore body, fractures and fissures in the rocks and is also brought in by ground water. Being the progenitor of a series of short lived radioisotopes it contributes over 70% of the radiation dose to mine workers and thus accounts for nearly 30% of the total radiation doses received by workers in the whole nuclear industry. This paper summarises the data on radon emanation from the ore body, backfilled sands and mine water. Radon and its progeny concentrations in different haulage levels and stopes of the Jaduguda uranium mine are presented to emphasise the need for a well planned ventilation system to control radiation exposure of miners. Results of radon monitoring from a few exploratory uranium mines are included to indicate the need for a good ventilation system from inception of the mining operations. Relative contribution of mine exhaust and tailings surfaces to the environmental radon are also given. Some instruments developed locally for monitoring of radon and its progeny in mines and in the environment are briefly described to indicate the progress made in this field. (author). 17 refs., 2 figs., 6 tabs

  3. Radon and energy efficient homes

    International Nuclear Information System (INIS)

    Burkart, W.

    1981-09-01

    Radon and its daughters in indoor air are presently responsible for dose equivalents of about 31 mSv/year (3 rem/year) to parts of the respiratory tract. Linear extrapolation from the dose response values of uranium miners heavily exposed to radon and its decay products would suggest that almost all lung cancers in the non-smoking population are caused by environmental 222 Rn. Using epidemiological data on the types of lung cancer found in non-smokers of the general public as compared to the miners, a smaller effect of low level radon exposure is assumed, which would result in a lung cancer mortality rate due to radon of about 10 deaths per year and million or 25% of the non-smoker rate. Higher indoor radon concentrations in energy efficient homes mostly caused by reduced air exchange rates will lead to a several fold increase of the lung cancer incidence from radon. Based on the above assumption, about 100 additional lung cancer deaths/year-million will result both from an increase in radionuclide concentrations in indoor air and a concomitant rise in effectiveness of radiation to cause cancer with higher exposure levels. Possibilities to reduce indoor radon levels in existing buildings and costs involved are discussed. (Auth.)

  4. Radon monitoring technique with electret collecting

    International Nuclear Information System (INIS)

    Tian Zhiheng; Zuo Fuqi; Xiao Detao; Zhao Xkiuliang

    1991-12-01

    The integrating radon monitoring technique with electret collecting is a method which collects the 218 Po + positive ions by electrostatic field produced by electret. It has greatly improved the sensitivity of radon measurement. The response factor of this method reaches to 4.7 cm -2 Bq -1 m 3 h -1 , 1000 times larger than that of common passive sampling method. The monitoring device and its principle are introduced. The measuring results of radon concentration and radon flux rate and quality assurance system by using this method in the Qinshan Nuclear Power Plant, Human Environmental Monitoring Central Station and some uranium mines are also presented. The analytical results show that the radon concentration in the Qinshan Nuclear Power Plant is affected by wind direction. When wind directs toward sea, the radon concentration is high. If the wind is to the contrary, it is low. The radon concentration ratio of both is about 2

  5. Characterizing the source of radon indoors

    International Nuclear Information System (INIS)

    Nero, A.V.; Nazaroff, W.W.

    1983-09-01

    Average indoor radon concentrations range over more than two orders of magnitude, largely because of variability in the rate at which radon enters from building materials, soil, and water supplies. Determining the indoor source magnitude requires knowledge of the generation of radon in source materials, its movement within materials by diffusion and convection, and the means of its entry into buildings. This paper reviews the state of understanding of indoor radon sources and transport. Our understanding of generation rates in and movement through building materials is relatively complete and indicates that, except for materials with unusually high radionuclide contents, these sources can account for observed indoor radon concentrations only at the low end of the range observed. Our understanding of how radon enters buildings from surrounding soil is poorer, however recent experimental and theoretical studies suggest that soil may be the predominant source in many cases where the indoor radon concentration is high. 73 references, 3 figures, 1 table

  6. Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment

    International Nuclear Information System (INIS)

    Marley, F.

    2000-01-01

    From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other standards for radon in the workplace. (author)

  7. Review of official measuring methods and official interpretations of measuring results used in the radon programme of the Czech Republic

    International Nuclear Information System (INIS)

    Thomas, J.; Hulka, J.; Fojtikova, I.

    2004-01-01

    Attention is centered on the following topics: 1. Preventive measures (Monitoring the radioactivity in building materials; Monitoring the radioactivity in drinking water; Monitoring the evaluating building sites; Evaluating finished unoccupied new buildings; Survey of occupied new buildings); 2. Measuring methods in the intervention programme (Identification of houses with elevated radon risk; Testing the effectiveness of mitigation; Searching for radon sources - radon diagnosis); 3. Metrological assurance of the Czech Radon Programme. (P.A.)

  8. Riddle of radon

    International Nuclear Information System (INIS)

    O'Riordan, M.

    1996-01-01

    Why is the most significant source of human exposure to ionising radiation - and one that is so easy to reduce - not accorded the attention it deserves from those engaged in radiological protection nor the action it requires from those affected by it at work or at home? There are, after all, clear indications that high levels of radon exist and firm strands of evidence that radon causes cancer. Some national and international authorities have even developed regulations and recommendations to limit exposures. But radon still lies in the penumbra of protection because proponents of intervention lack conviction and opponents are full of passionate intensity. Little wonder that citizens are confused! (Author)

  9. Prototype exposure chamber of radon for animal experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yuji; Koizumi, Akira; Yonehara, Hidenori; Shimo, Michikuni; Inaba, Jiro [National Institute of Radiological Sciences, Chiba (Japan)

    1998-12-31

    To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As career aerosols of radon progeny, carnauba wax aerosols as solid particles, DOS aerosols as liquid particles and NaCl aerosols as hygroscopic particles were selected. These aerosols generated using a vaporization-condensation method and/or an electrical classification method were almost monodisperse with {sigma}{sub g} of <1.2. The monitoring data on biologically related gases showed an importance in the oxygen injection system and the carbon dioxide absorption system. (author)

  10. Summary of EPA's radon-reduction research in schools during 1989-90

    International Nuclear Information System (INIS)

    Leovic, K.W.

    1990-10-01

    The report details radon mitigation research in schools conducted by EPA during 1989 and part of 1990. The major objective was to evaluate the potential of active subslab depressurization (ASD) in various geologic and climatic regions. The different geographic regions also presented a variety of construction types and heating, ventilating, and air-conditioning (HVAC) system designs that are encountered in radon mitigation of school buildings. A secondary objective was to initiate research in difficult-to-mitigate schools. The research led to the following major conclusions on radon diagnostics and mitigation in schools: (1) Schools have many physical characteristics that typically make their mitigation more complex than house mitigation, including building size and substructure, subslab barriers, HVAC systems, and locations of utility lines. (2) Important school diagnostic procedures and measurements include review of radon measurements and building plans, investigation of the building to assess potential radon entry routes and confirm information in the building plans, analysis of the HVAC system and its influence on pressure differentials and radon levels, and subslab pressure field extension measurements to determine the potential applicability of ASD. (3) ASD can be applied successfully in schools where subslab communication barriers are limited

  11. Tracing and dealing with dwellings with high radon and radon daughter concentrations

    International Nuclear Information System (INIS)

    Ehdwall, Hans

    1980-01-01

    In the late 1970s it was found that a number of buildings in Sweden, primarily those made from alum shale-based concretes, had elevated radon and radon daughter levels. A special commission investigated the problem and established provisional limiting values for radon daughter exposures, gamma radiation from the ground, and the concentrations of radioactive materials in building materials. With regard to gamma radiation from the ground the commission proposed that no building be built in an area where outside gamma radiation exceeds 100 μR/h. For building materials a gamma index (mγ) and a radium index (mRa) are suggested: mγ = Csub(K)/10000 + Csub(Ra)/1000 + Csub(Th)/700; mRa = Csub(Ra)/200 (Csub(K), Csub(Ra) and Csub(Th) are the concentrations of potassium, radium and thorium respectively). The proposed limiting values are such that the gamma index and the radium index be less than 1. It is also suggested that action should be taken to reduce radon levels in buildings with radon daughter concentrations of 0.27 WL within two years and 0.10 WL within 5 years

  12. Environmental radon and cancer risk

    Energy Technology Data Exchange (ETDEWEB)

    Haque, A K.M.M.; Kirk, A E [South Bank Polytechnic, London (United Kingdom)

    1992-01-01

    Data collected from the office of Population Censuses and Surveys (OPCS) statistics and those published by the Leukaemia Research Fund (LRF) have been analysed with a view to examining whether radon is a possible causative agent in the induction of leukaemias. Radon concentration values have been taken from a NRPB survey. Positive correlation has been observed between radon concentration and incidence of acute myeloid leukaemia (AML), chronic myeloid leukaemia (CML), acute lymphoblastic leukaemia (ALL) and chronic lymphoid leukaemia (CLL). Employing the method of BEIR IV, the lifetime probability of leukaemia incidence, R[sub o], of a non-exposed person (zero radon concentration) has been calculated for AML, CML, ALL and CLL, which agree well with those values obtained from extrapolation of linear graphs of leukaemia deaths versus radon concentration. (author).

  13. Radon Infiltration in Rented Accommodation

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2017-01-01

    in homes was measured and the Buildings were registered for a series of variables describing upgrades, facilities, building components, Construction characteristics and used materials. In addition, the radon level was measured in the basement in 9 of the buildings. The mean year value of the indoor radon......Indoor radon levels were measured in 221 homes located in 53 buildings, including 28 multi-occupant houses and 25 single-family terraced houses. The homes consisted of rented accommodation located in buildings recorded as being constructed before 2010 and after the year 1850. The radon level...... radon levels exceeding 100 Bq/m3 in homes in multi-occupant houses was found to be very low, but the risk was highest on the ground floor in a building constructed with slab on ground....

  14. Determination of equilibrium factor between radon and its progeny using surface barrier detector for various shapes of passive radon dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Jamil, K. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Fazal-ur-Rehman [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Ali, S. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Khan, H.A. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group

    1997-03-21

    In the field of radon dosimetry, it is customary to measure radon ({sup 222}Rn) concentration while potential health hazard is due to the radon short-lived progeny. When radon is in secular equilibrium, the measured activity of radon equals the activity of radon`s progeny. However, in practical cases an inequilibrium between radon and its progeny exists which is measured in terms of the equilibrium factor. To determine the equilibrium factor between radon and its progeny in a closed environment various shapes of passive dosimeters based upon solid state nuclear track detectors (SSNTDs) are employed. In order to observe the dependence of equilibrium factor upon shapes or effective volumes, experiments have been performed replacing the SSNTDs with a surface barrier detector in Karlsruhe diffusion chamber, pen-type and box-type dosimeters. Using the collected alpha spectra, the equilibrium factor has been determined for a radon-air mixture in a custom designed radon chamber simulating a closed environment of a room. The results show that the radon equilibrium factor is about 0.20 for different shapes of dosimeters studied in this research. It is concluded that the determination of equilibrium factor between radon and its progeny does not depend upon effective volume or shape of the passive dosimeters using alpha spectroscopic data acquired by surface barrier detector. (orig.).

  15. Paloma-radon: Atmospheric radon-222 as a geochemical probe for water in the Martian subsoil.

    Science.gov (United States)

    Sabroux, J.-C.; Michielsen, N.; Voisin, V.; Ferry, C.; Richon, P.; Pineau, J.-F.; Le Roulley, J.-C.; Chassefière, E.

    2003-04-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon-222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES-supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m^3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO_2). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option (already on board the Mars Pathfinder Rover and other platforms). In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a

  16. An evaluation of the quantitative effects on radon gas from the modification of a home heating and air conditioning system

    International Nuclear Information System (INIS)

    Montague, A.

    1991-01-01

    The quantitative effects associated with the design, construction, operation, environmental and meteorological conditions on radon gas levels in a typical residential dwelling with a basement, having a measured radon level of approximately 20 pico-curies/liter (pCi/L), are evaluated. After several mechanical and electrical modifications are made on the dwelling's heating system, two different furnace breathing modes are studied. The effect on radon levels in the dwelling are observed as the furnace receives all of its combustion, draft and ventilation air - as the experiment alternates, on a bi-weekly basis - from inside and then outside the dwelling. Radon, barometric pressure, outside temperature, relative humidity, wind-speed and direction are monitored continuously; special household activity in the dwelling is also observed. A novel differential air pressure technique is used to measure inside versus outside house air pressure variations, twice each day, resulting from meteorological conditions, dwelling activity, and the furnace breathing mode. A rigorous statistical analysis is employed that includes sequential linear regression of time-series data, trend corrections to remove variations that contribute to the variance in the data without addition useful information. A novel approach using an electrical analog, to screen out unwanted variations is applied, by utilizing a computer routine to simulate the effect of an electronic RC filter, to achieve the desired analytical discrimination

  17. Effective diffusion coefficient of radon in concrete, theory and method for field measurements

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1976-01-01

    A linear diffusion model serves as the basis for determination of an effective radon diffusion coefficient in concrete. The coefficient was needed to later allow quantitative prediction of radon accumulation within and behind concrete walls after application of an impervious radon barrier. A resolution of certain discrepancies noted in the literature in the use of an effective diffusion coefficient to model diffusion of a radioactive gas through a porous medium is suggested. An outline of factors expected to affect the concrete physical structure and the effective diffusion coefficient of radon through it is also presented. Finally, a field method for evaluating effective radon diffusion coefficients in concrete is proposed and results of measurements performed on a concrete foundation wall are compared with similar published values of gas diffusion coefficients in concrete. (author)

  18. Radon: Chemical and physical states of radon progeny. Final technical report

    International Nuclear Information System (INIS)

    Castleman, A.W. Jr.

    1996-01-01

    The evolving chemical and physical form of radon progeny influence their transport to the bioreceptor and the extent to which that receptor can take up these species into various tissues. When first born following radioactive decay processes, the potentially deleterious radon progeny undergo various physical and chemical transformations as they transcend from a highly charged to a neutral state, and interact with various constituents of the environment. These transformations impact on the extent to which the radon progeny become associated with aerosol particles on the one hand, and their ultimate chemical form that is available for uptake in the biosystem, on the other. The program, which originally commenced in 1987, dealt with the basic chemistry and physics of radon progeny and hence impacted on several themes of importance to the DOE/OHER radon program. One of these is dose response, which is governed by the physical forms of the radon progeny, their transport to the bioreceptor and the chemical forms that govern their uptake. The second theme had to do with cellular responses, one of the major issues motivating the work. It is well known that various sizes of ions and molecules are selectively transported across cell membrane to differing degrees. This ultimately has to do with their chemical and physical forms, charge and size. The overall objective of the work was threefold: (1) quantifying the mechanisms and rates of the chemical and physical transformation; (2) ascertaining the ultimate chemical forms, and (3) determining the potential interactions of these chemical species with biological functional groups to ascertain their ultimate transport and incorporation within cells

  19. Radon in coal power plant areas

    International Nuclear Information System (INIS)

    Mauna, Traian; Mauna, Andriesica

    2006-01-01

    Radon, the radioactive colourless and inodorous noble gas, represents more than 55% of the natural average radioactivity. It is permanently released from the soil and majority of building materials, it builds up in the mine galleries, in dwelling houses and in other closed rooms. Radon gained increasingly in importance, particularly after 1990 when was doubtless identified as the second cause of lung cancer if a given concentration threshold is surpassed. This threshold is established differentially by each country as a function of the particular site and generally ranges between 150 Bq.m -3 and 600 Bq.m -3 . The telluric radon consists of two isotopes, 222 Rn, a daughter of radium descending from uranium, which induces 90% of the effects, and 220 Rn from thorium series which have too short a lifetime to count in the risk assessments of radon inhalation. The interest of the authorities and population for diminishing the radon effects was illustrated by specific studies which in USA were managed by the National Counsel of Research, the BEIR VI committee of which has issued a report concerning the lung cancer produced by radon and its descendants. Coal mining, the transport, processing, burning, slag and ash disposal are activities entailing radon release. The miners' dwellings are placed in areas with the high radon potential. The local building materials have a high content of radioactive elements from the uranium or thorium series so that radon can build up in the closed rooms of these buildings. Hence the social responsible authorities in the coal power industry zones should consider this aspect long time ignored in the Balkans macro zone so far. The radon issue must be differentially approached in different areas hence a zonal mapping of the radon emission should be first done. It is worth to underline that the gaseous radioactive emission from operational nuclear power plants amounts up to a few percents of the radon natural emissions what entails a

  20. Radon and remedial action in Spokane River Valley residences: an interim report

    International Nuclear Information System (INIS)

    Turk, B.H.; Prill, R.J.; Fisk, W.J.; Grimsrud, D.T.; Moed, B.A.; Sextro, R.G.

    1986-03-01

    Fifty-six percent of 46 residences monitored in the Spokane River Valley in eastern Washington/northern Idaho have indoor radon concentrations above the National Council for Radiation Protection (NCRP) guidelines of 8 pCi/1. Indoor levels were over 20 pCi/1 in eight homes, and ranged up to 132 pCi/1 in one house. Radon concentrations declined by factors of 4 to 38 during summer months. Measurements of soil emanation rates, domestic water supply concentrations, and building material flux rates indicate that diffusion of radon does not significantly contribute to the high concentrations observed. Rather, radon entry is dominated by pressure-driven bulk soil gas transport, aggravated by the local subsurface soil composition and structure. A variety of radon control strategies are being evaluated in 14 of these homes. Sub-surface ventilation by depressurization and overpressurization, basement overpressurization, and crawlspace ventilation are capable of successfully reducing radon levels below 5 pCi/1 in these homes. House ventilation is appropriate in buildings with low-moderate concentrations, while sealing of cracks has been relatively ineffective

  1. Radon chamber for soil gas detectors

    International Nuclear Information System (INIS)

    Andersson, P.

    1987-01-01

    Swedish Geological Co (SGAB) has designed and constructed a chamber for the calibration of detectors and instruments intended for the measurement of radon-222 in soil gas. In the chamber radon detectors may be exposed in a model environment which simulates ground conditions with respect to radon concentration, temperature and humidity. Also included in the research project is the development of methods for calibration procedures, together with test measurements. In general, these measurements indicate that the radon detectors tested are sufficiently accurate and reliable for radon measurements in Swedish soils if they are calibrated in an environment which simulates ground conditions. (orig./HP)

  2. Radon adsorption on present activated charcoals

    International Nuclear Information System (INIS)

    Kazankin, Yu.N.; Trofimov, A.M.; Mikhajlova, L.K.

    1978-01-01

    Radon adsorption from helium and air has been studied on modern activated carbons of SKT-1, SKT-2a, SKT-3, SKT-2b, SKT-6, PAU-1 within the temperature range from 100 to 80 deg. It has been shown that PAU-1 carbon has the highest activity with respect to radon in the temperature range studied. With decreasing temperature the adsorption coefficients increase sharply. It has been found that for the case of radon adsorption from helium the logarythm of the Henry coefficient linearly depends on the inverse value of absolute temperature. Adsorption of radon from air is inhibited and the above-cited relationship is deviated from linear. The results of calculating differential heats of radon and air adsorption as well as coefficients of radon and air separation on carbons are presented

  3. NORM and radon in Austria. Status and strategy; Norm und Radon in Oesterreich. Status und Strategie

    Energy Technology Data Exchange (ETDEWEB)

    Maringer, F.J. [Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2013-07-01

    The author reviews the actual radiation protection practice in Austria for NORM and radon, including possible strategies and developments. Specific topics are radiation protection technologies, metrological resources for NORM in Austria, civil engineering standards (OeNORM) for radon measurement, radon prevention for new buildings and radon cleansing for existing buildings, future assessment and legal regulation of radioactivity in construction materials. The strategic development in Austria considers the current European standard projects (EU standards) and European and international research programs.

  4. Comparative survey of outdoor, residential and workplace radon concentrations

    International Nuclear Information System (INIS)

    Barros, Nirmalla; Field, R. William; Field, Dan W.; Steck, Daniel J.

    2015-01-01

    This study investigated radon concentrations in above-ground (i.e. first floor) workplace in Missouri and compared them with above-ground radon concentrations in nearby homes and outdoor locations. This study also examined the potential utility of using home and outdoor radon concentrations to predict the radon concentration at a nearby workplace (e.g. county agencies and schools). Even though workplace radon concentrations were not statistically different from home radon concentrations, the radon concentration at a particular home, or outdoor location, was a poor predictor of the radon concentration at a nearby workplace. Overall, 9.6 and 9.9 % of homes and workplace, respectively, exhibited radon concentrations of ≥148 Bq m -3 . Because of the percentage of workplace with elevated radon concentrations, the results suggest that additional surveys of workplace radon concentrations are needed, especially in areas of high radon potential, to assess the contribution of workplace radon exposure to an individual's overall radon exposure. (authors)

  5. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  6. Factors influencing radon attenuation by tailing covers

    International Nuclear Information System (INIS)

    Silker, W.B.; Rogers, V.C.

    1981-07-01

    The US NRC, in its Generic Environmental Impact Statement on uranium milling has specified that the radon flux escaping a uranium mill tailings pile will be reduced to pCi/m 2 s by application of covering layers of soils and clays. These covers present a radon diffusion barrier, which sufficiently increases the time required for radon passage from the tailings to the atmosphere to allow for decay of 222 Rn within the cover. The depth of cover necessary to reduce the escaping radon flux to the prescribed level is to be determined by calculation, and requires precise knowledge of the radon diffusion coefficient in the covering media. A Radon Attenuation Test Facility was developed to determine rates of radon diffusion through candidate cover materials. This paper describes this facility and its application for determining the influence of physical properties of the soil column on the radon diffusion coefficient

  7. Application of underwater radon measurements in geology

    Energy Technology Data Exchange (ETDEWEB)

    Varhegyi, A.; Baranyi, I.; Gerzson, I. (Mecsek Ore Mining Enterprise, Pecs (Hungary)); Somogyi, G.; Hakl, J.; Hunyadi, I. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete)

    1988-01-01

    Based on the observed phenomenon of geogas migration in microbubble form from deeper regions, the authors have developed a new model for the vertical transport of radon released from deeper sources. The physical properties of the rock relating to the upflow of microbubbles below the groundwater level are considered and the radon transport parameter of rocks is introduced. The vertical distribution of radon concentration in the case of a multi-layered geological model is given and the penetration depth of underwater radon measurements is examined. Aspects of underwater radon detection by the nuclear track detector technique are analyzed. The radon transport model gives a new theoretical basis for several applications of radon measurements in geology. The advantages of underwater radon detection have already been proved in uranium exploration. Further geological applications are proposed in earthquake prediction, in volcanology, in the survey of active faults and thermal waters. (author).

  8. Radon: A health problem

    International Nuclear Information System (INIS)

    Pucci, J.; Gaston, S.

    1990-01-01

    Nurses can and should function as effective teachers about the potential hazards to health of radon contamination in the home as well as become activists in the development of health care policy on radon

  9. Comparative study on radon effects and thermal effects on humans in radon hot spring therapy

    International Nuclear Information System (INIS)

    Yamaoka, K.; Mitsunobu, F.; Hanamoto, K.; Tanizaki, Y.; Sugita, K.; Kohima, S.

    2003-01-01

    Full text: The radon therapy is used radon ( 222 Rn) gas, which mainly emits alpha-rays, and induces a small amount of active oxygen in the body. Because most of the diseases to which the radon therapy as well as the thermal therapy is applied are related to activated oxygen, in this study the effects of the radioactivity of radon and thermal effects were compared under the room or the hot spring condition with the similar chemical component, using as the parameters which are closely involved in the clinical for radon therapy. In the results, the radon and thermal therapy enhanced the antioxidation function, such as the activities of superoxide dismutase (SOD) and catalase, which inhibit lipid peroxidation and total cholesterol produce in the body. Moreover the therapy enhanced concanavalin A (ConA)-induced mitogen response, and increased the level of CD4, which is the marker of helper T cell, and decreased the level of CD8, which is the common marker of killer T cell and supresser T cell, in the white cell differentiation antigen (CD4/CD8) assay. Furthermore, the therapy increased the levels of alpha atrial natriuretic polypeptide (alpha ANP), beta endorphin, adrenocorticotropic hormone (ACTH), insulin and glucose-phosphate dehydrogenase (G-6-PDH), and decreased the vasopression level. The results were on the whole larger in the radon group than in the thermal group. The findings suggest that the radon therapy more contributes to the prevention of life style-related diseases related to peroxidation reactions and immune depression than thermal therapy. Moreover these indicate what may be a part of the mechanism for the alleviation of hypertension, osteoarthritis (pain) and diabetes mellitus brought about more radon therapy than thermal therapy

  10. Radon releases from Australian uranium mining and milling projects: assessing the UNSCEAR approach.

    Science.gov (United States)

    Mudd, Gavin M

    2008-02-01

    The release of radon gas and progeny from the mining and milling of uranium-bearing ores has long been recognised as a potential radiological health hazard. The standards for exposure to radon and progeny have decreased over time as the understanding of their health risk has improved. In recent years there has been debate on the long-term releases (10,000 years) of radon from uranium mining and milling sites, focusing on abandoned, operational and rehabilitated sites. The primary purpose has been estimates of the radiation exposure of both local and global populations. Although there has been an increasing number of radon release studies over recent years in the USA, Australia, Canada and elsewhere, a systematic evaluation of this work has yet to be published in the international literature. This paper presents a detailed compilation and analysis of Australian studies. In order to quantify radon sources, a review of data on uranium mining and milling wastes in Australia, as they influence radon releases, is presented. An extensive compilation of the available radon release data is then assembled for the various projects, including a comparison to predictions of radon behaviour where available. An analysis of cumulative radon releases is then developed and compared to the UNSCEAR approach. The implications for the various assessments of long-term releases of radon are discussed, including aspects such as the need for ongoing monitoring of rehabilitation at uranium mining and milling sites and life-cycle accounting.

  11. Radon releases from Australian uranium mining and milling projects: assessing the UNSCEAR approach

    International Nuclear Information System (INIS)

    Mudd, Gavin M.

    2008-01-01

    The release of radon gas and progeny from the mining and milling of uranium-bearing ores has long been recognised as a potential radiological health hazard. The standards for exposure to radon and progeny have decreased over time as the understanding of their health risk has improved. In recent years there has been debate on the long-term releases (10,000 years) of radon from uranium mining and milling sites, focusing on abandoned, operational and rehabilitated sites. The primary purpose has been estimates of the radiation exposure of both local and global populations. Although there has been an increasing number of radon release studies over recent years in the USA, Australia, Canada and elsewhere, a systematic evaluation of this work has yet to be published in the international literature. This paper presents a detailed compilation and analysis of Australian studies. In order to quantify radon sources, a review of data on uranium mining and milling wastes in Australia, as they influence radon releases, is presented. An extensive compilation of the available radon release data is then assembled for the various projects, including a comparison to predictions of radon behaviour where available. An analysis of cumulative radon releases is then developed and compared to the UNSCEAR approach. The implications for the various assessments of long-term releases of radon are discussed, including aspects such as the need for ongoing monitoring of rehabilitation at uranium mining and milling sites and life-cycle accounting

  12. The matter of radon

    International Nuclear Information System (INIS)

    O'Riordan, M.C.; O'Riordan, C.N.

    1992-01-01

    By comparison with the radiation doses from radon, the doses to individual members of the public and to the general community from nuclear activities are quite trivial. Doses from radon in some British homes exceed the statutory dose limit for nuclear workers;the collective dose from radon is two thousand times the value for nuclear discharges. And yet, too little attention - legal or otherwise - is paid to this radioactive pollutant. An attempt is made in this paper to compensate for the neglect. The origins, properties and harmful effects of radon are described. Measurements in homes and places of work are summarised. Voluntary and regulatory controls on exposure are elucidated. Questions of public administration, confidentiality of information and sale of property are discussed. Prospects for progress are assessed. (author)

  13. Passive radon daughter dosimeters

    International Nuclear Information System (INIS)

    McElroy, R.G.C.; Johnson, J.R.

    1986-03-01

    On the basis of an extensive review of the recent literature concerning passive radon daughter dosimeters, we have reached the following conclusions: 1) Passive dosimeters for measuring radon are available and reliable. 2) There does not presently exist an acceptable passive dosimeter for radon daughters. There is little if any hope for the development of such a device in the foreseeable future. 3) We are pessimistic about the potential of 'semi-passive dosimeters' but are less firm about stating categorically that these devices cannot be developed into a useful radon daughter dosimeter. This report documents and justifies these conclusions. It does not address the question of the worker's acceptance of these devices because at the present time, no device is sufficiently advanced for this question to be meaningful. 118 refs

  14. Radon levels in Croatian spas

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Stanic, D.; Planinic, J.

    2005-01-01

    Average radon concentrations in the air and geothermal water of spa pools in Croatia were 40.3 Bq/m 3 and 4.5 kBq/m 3 , respectively. Substantial difference between radon concentrations in pool and spring water is explained by the mixing normal and geothermal water in the pool and with radon decay. The estimated annual effective dose received by the personnel in the spa of Stubicke toplice, Croatia was 0.7 mSv. At the same location, the calculated transfer factor of radon for the air and thermal water in the pool was 4.9x10 -3 .(author)

  15. Activity measurements of radon from construction materials.

    Science.gov (United States)

    Fior, L; Nicolosi Corrêa, J; Paschuk, S A; Denyak, V V; Schelin, H R; Soreanu Pecequilo, B R; Kappke, J

    2012-07-01

    This work presents the results of radon concentration measurements of construction materials used in the Brazilian industry, such as clay (red) bricks and concrete blocks. The measurements focused on the detection of indoor radon activity during different construction stages and the analysis of radionuclides present in the construction materials. For this purpose, sealed chambers with internal dimensions of approximately 60×60×60 cm3 were built within a protected and isolated laboratory environment, and stable air humidity and temperature levels were maintained. These chambers were also used for radon emanation reduction tests. The chambers were built in four major stages: (1) assembly of the walls using clay (red) bricks, concrete blocks, and mortar; (2) installation of plaster; (3) finishing of wall surface using lime; and (4) insulation of wall surface and finishing using paint. Radon measurements were performed using polycarbonate etched track detectors. By comparing the three layers applied to the masonry walls, it was concluded that only the last step (wall painting using acrylic varnish) reduced the radon emanation, by a factor of approximately 2. Samples of the construction materials (clay bricks and concrete blocks) were ground, homogenized, and subjected to gamma-ray spectrometry analysis to evaluate the activity concentrations of 226Ra, 232Th and 40K. The values for the index of the activity concentration (I), radium equivalent activity (Raeq), and external hazard index (Hext) showed that these construction materials could be used without restrictions or concern about the equivalent dose limit (1 mSv/year). Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Measurement of concentration and size distribution of radon decay products in homes using air cleaners

    International Nuclear Information System (INIS)

    Montassier, N.; Hopke, P.K.; Shi, Y.; McCallum, B.

    1992-01-01

    By removing particles, air cleaners can also eliminate radon decay products. However, by removing the particles, the open-quotes unattachedclose quotes fraction of the radon progeny is increased leading to a higher dose per unit exposure. Thus, both the concentration and size distributions of the radon decay products are needed to evaluate air cleaners. Three types of room air cleaners, NO-RAD Radon Removal System, Electronic Air Cleaner and PUREFLOW Air Treatment System were tested in a single family home in Arnprior, Ontario (Canada). Semi-continuous measurements of radon gas concentration and radon decay product activity weighted size distribution were performed in the kitchen/dining room under real living conditions. The effects of air cleaners on both the concentration and size distribution of the radon decay products were measured, and their impact on the dose of radiation given to the lung tissue were examined

  17. Risk of lung cancer by radon, disagreement in international regulation; Riesgo de cancer pulmonar por radon, discordancia en reglamentacion internacional

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, M.; Pena, P.; Villamares, A.; Avelar, J. R., E-mail: miguel.balcazar@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    Diverse international organizations have evaluated the risk of lung cancer starting from epidemic studies in miners of uranium mines, where the corresponding effective dose was determined relating with the dose received by the population during Hiroshima and Nagasaki events. Alternately, the equivalent dose has been calculated by means of based models on the energy deposited by the breathable radon fractions and its decay products in the breathing ducts. A unique factor agreed by the diverse organizations that allows converting radon concentration to effective dose does not exist. Neither an agreement exists among the different countries on which duty to be the value of the maximum concentration of radon, in interiors starting from which an intervention is required and if this intervention is standardized, recommended or nonexistent. In this work study cases in Mexico are presented and their interpretation alternative based on the international agreements absence. (Author)

  18. Evaluation of 222radon occupational exposure in underground workplaces: tunnels used for mushroom cultivation in Italy

    International Nuclear Information System (INIS)

    Fontana, C.; Vecchiariello, S.; Angeloni, U.; Trevisi, R.; Tonnarini, S.

    2006-01-01

    The mushroom cultivation in tunnels represents a working activity with interesting characteristics from a radiological protection point of view. The practice of using tunnels or caves for the cultivation of mushrooms is diffused in many countries as well as in several Italian regions. These places are characterized by micro climate conditions (temperature, humidity, etc.) particularly adapted for the growth of mushrooms in every period of the year. This practice, like every working activity carried out in underground workplaces, is regulated by the Italian implementation of the European Union Basic Safety Standards (E.U. B.S.S., 1996). With the aim to evaluate the 222 Rn exposure of workers in tunnels used for mushroom cultivation, a study has been undertaken. In particular, hygienic and micro climatic characteristics (depth, temperature, relative humidity, barometric pressure, ventilation, etc.) and radiometric parameters (indoor radon concentration, radon decay products concentration, equilibrium factor F) have been investigated. In the present paper, the results of the two steps of the study are reported. In the first step, an operative protocol has been defined: the protocol was put through a series of measurements in two tuff tunnels in the area of Rome. In the second step, several tunnels used for mushroom cultivation, located in different Italian regions, have been monitored and experimental data have been used to estimate annual effective doses of workers due to radon inhalation.The experimental results have been analyzed in the context of the E.U. B.S.S

  19. Radon survey and soil gamma doses in primary schools of Batman, Turkey.

    Science.gov (United States)

    Damla, Nevzat; Aldemir, Kamuran

    2014-06-01

    A survey was conducted to evaluate levels of indoor radon and gamma doses in 42 primary schools located in Batman, southeastern Anatolia, Turkey. Indoor radon measurements were carried out using CR-39 solid-state nuclear track detector-based radon dosimeters. The overall mean annual (222)Rn activity in the surveyed area was found to be 49 Bq m(-3) (equivalent to an annual effective dose of 0.25 mSv). However, in one of the districts (Besiri) the maximum radon value turned out to be 307 Bq m(-3). The estimated annual effective doses are less than the recommended action level (3-10 mSv). It is found that the radon concentration decreases with increasing floor number. The concentrations of natural and artificial radioisotopes were determined using gamma-ray spectroscopy for soil samples collected in close vicinity of the studied schools. The mean gamma activity concentrations in the soil samples were 31, 25, 329 and 12 Bq kg(-1) for (226)Ra, (232)Th, (40)K and (137)Cs, respectively. The radiological parameters such as the absorbed dose rate in air and the annual effective dose equivalent were calculated. These radiological parameters were evaluated and compared with the internationally recommended values.

  20. Application of CR-39 to radon measurement

    International Nuclear Information System (INIS)

    Miyake, Hiroshi

    1988-01-01

    CR-39, an ally diglycol carbonate, has recently come into wider use as material for solid-state track detector. Etching with NaOH or KOH solution allow CR-39 to develop extremely clear etch pits attributed to alpha rays. The most widely used method for measuring radon concentration employs a plastic cup with a solid-state track detector mounted at its bottom to detect alpha rays resulting from radon or its daughters that disintegrate within or on the wall of the cup. Simple in mechanism and low in cost, this method is suitable for such a case where the radon concentration distribution over a wide area has to be measured by using a large number of devices. The concentration of radon alone can be measured with the aid of a filter attached to the mouth of the cup to remove the daughters of radon and thoron. The simplest and most effective way of improving the sensitivity of a solid-state track detector for radon concentration measurement is to electrostatically collect daughters resulting from decay of radon onto the surface of the detector. Another method widely used to determine the radon concentration is to measure the concentration of the radon daughters instead of direct measurement of the concentration of radon itself. (Nogami, K.)