WorldWideScience

Sample records for neglect test battery

  1. Battery Post-Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Post-test diagnostics of aged batteries can provide additional information regarding the cause of performance degradation, which, previously, could be only inferred...

  2. Open stack thermal battery tests

    Energy Technology Data Exchange (ETDEWEB)

    Long, Kevin N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Roberts, Christine C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Grillet, Anne M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Headley, Alexander J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Fenton, Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wong, Dennis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ingersoll, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-04-17

    We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transverse to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.

  3. The Computerized Table Setting Test for Detecting Unilateral Neglect.

    Directory of Open Access Journals (Sweden)

    Seok Jong Chung

    Full Text Available Patients with unilateral neglect fail to respond normally to stimuli on the left side. To facilitate the evaluation of unilateral spatial neglect, we developed a new application that runs on a tablet device and investigated its feasibility in stroke patients.We made the computerized table setting test (CTST to run on the tablet computer. Forty acute ischemic stroke patients (20 patients with right hemispheric infarction with neglect, 10 patients with right hemispheric infarction without neglect, and 10 patients with left hemispheric infarction and 10 healthy controls were prospectively enrolled to validate the CTST. The test requires subjects to set a table by dragging 12 dishes located below the table on the tablet screen. The horizontal deviation of the 12 dishes from the midline of the table, the selection tendency measured by the sequence of the dish selection, and the elapsed time for table setting were calculated automatically.Parameters measured by the CTST were correlated with the results of conventional neglect tests. The horizontal deviation was significantly higher in patients with right hemispheric infarction with neglect compared with the other groups. The selection tendency and elapsed time also were significantly different in patients with right hemispheric infarction with neglect compared with the left hemispheric infarction and control groups, but were similar to those with right hemispheric infarction without neglect.The CTST is feasible to administer and comparable with conventional neglect tests. This new application may be useful for the initial diagnosis and follow-up of neglect patients.

  4. The Computerized Table Setting Test for Detecting Unilateral Neglect

    Science.gov (United States)

    Ye, Byoung Seok; Lee, Hye Sun; Chang, Hyuk-Jae; Song, Dongbeom; Kim, Young Dae; Heo, Ji Hoe; Nam, Hyo Suk

    2016-01-01

    Background Patients with unilateral neglect fail to respond normally to stimuli on the left side. To facilitate the evaluation of unilateral spatial neglect, we developed a new application that runs on a tablet device and investigated its feasibility in stroke patients. Methods We made the computerized table setting test (CTST) to run on the tablet computer. Forty acute ischemic stroke patients (20 patients with right hemispheric infarction with neglect, 10 patients with right hemispheric infarction without neglect, and 10 patients with left hemispheric infarction) and 10 healthy controls were prospectively enrolled to validate the CTST. The test requires subjects to set a table by dragging 12 dishes located below the table on the tablet screen. The horizontal deviation of the 12 dishes from the midline of the table, the selection tendency measured by the sequence of the dish selection, and the elapsed time for table setting were calculated automatically. Results Parameters measured by the CTST were correlated with the results of conventional neglect tests. The horizontal deviation was significantly higher in patients with right hemispheric infarction with neglect compared with the other groups. The selection tendency and elapsed time also were significantly different in patients with right hemispheric infarction with neglect compared with the left hemispheric infarction and control groups, but were similar to those with right hemispheric infarction without neglect. Conclusions The CTST is feasible to administer and comparable with conventional neglect tests. This new application may be useful for the initial diagnosis and follow-up of neglect patients. PMID:26771512

  5. Strain measurement based battery testing

    Science.gov (United States)

    Xu, Jeff Qiang; Steiber, Joe; Wall, Craig M.; Smith, Robert; Ng, Cheuk

    2017-05-23

    A method and system for strain-based estimation of the state of health of a battery, from an initial state to an aged state, is provided. A strain gauge is applied to the battery. A first strain measurement is performed on the battery, using the strain gauge, at a selected charge capacity of the battery and at the initial state of the battery. A second strain measurement is performed on the battery, using the strain gauge, at the selected charge capacity of the battery and at the aged state of the battery. The capacity degradation of the battery is estimated as the difference between the first and second strain measurements divided by the first strain measurement.

  6. Advanced integrated battery testing and simulation

    Science.gov (United States)

    Liaw, Bor Yann; Bethune, Keith P.; Yang, Xiao Guang

    The recent rapid expansion in the use of portable electronics, computers, personal data assistants, cellular phones, power tools, and even electric and hybrid vehicles creates a strong demand on fast deployment of battery technologies at an unprecedented rate. To facilitate such a development integrated battery testing and simulation (IBTS) using computer modeling is an effective tool to improve our capability of rapid prototyping battery technology and facilitating concurrent product development. In this paper, we will present a state-of-the-art approach to use IBTS for improvements in battery cell design, operation optimization, and even charge control for advanced batteries.

  7. Li-ion EMU Battery Testing

    Science.gov (United States)

    Rehm, Raymond; Bragg, Bobby; Strangways, Brad

    2001-01-01

    A 45Ah Lithium ion (Li-Ion) battery comprised of 5 Yardney prismatic cells was evaluated to replace the silver-zinc cells in the Extra-vehicular Mobility Unit (EMU). Tests determined that the five cell battery can meet the mission objective of 500 duty cycles and maintain a minimum voltage of 16.0 V without an individual cell voltage dropping below 3.0V. Forty real time cycles were conducted to develop BOL trend data. Decision to switch to accelerated cycling for the remaining 460 cycles was made since Real Time cycling requires 1 day/cycle. Conclusions indicate that battery replacement would indeed be prudent.

  8. Cursor Control Device Test Battery

    Science.gov (United States)

    Holden, Kritina; Sandor, Aniko; Pace, John; Thompson, Shelby

    2013-01-01

    The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not

  9. [European Portuguese EARS test battery adaptation].

    Science.gov (United States)

    Alves, Marisa; Ramos, Daniela; Oliveira, Graça; Alves, Helena; Anderson, Ilona; Magalhães, Isabel; Martins, Jorge H; Simões, Margarida; Ferreira, Raquel; Fonseca, Rita; Andrade, Susana; Silva, Luís; Ribeiro, Carlos; Ferreira, Pedro Lopes

    2014-01-01

    The use of adequate assessment tools in health care is crucial for the management of care. The lack of specific tools in Portugal for assessing the performance of children who use cochlear implants motivated the translation and adaptation of the EARS (Evaluation of Auditory Responses to Speech) test battery into European Portuguese. This test battery is today one of the most commonly used by (re)habilitation teams of deaf children who use cochlear implants worldwide. The goal to be achieved with the validation of EARS was to provide (re)habilitation teams an instrument that enables: (i) monitoring the progress of individual (re)habilitation, (ii) managing a (re)habilitation program according to objective results, comparable between different (re)habilitation teams, (iii) obtaining data that can be compared with the results of international teams, and (iv) improving engagement and motivation of the family and other professionals from local teams. For the test battery translation and adaptation process, the adopted procedures were the following: (i) translation of the English version into European Portuguese by a professional translator, (ii) revision of the translation performed by an expert panel, including doctors, speech-language pathologists and audiologists, (iii) adaptation of the test stimuli by the team's speechlanguage pathologist, and (iv) further review by the expert panel. For each of the tests that belong to the EARS battery, the introduced adaptations and adjustments are presented, combining the characteristics and objectives of the original tests with the linguistic and cultural specificities of the Portuguese population. The difficulties that have been encountered during the translation and adaptation process and the adopted solutions are discussed. Comparisons are made with other versions of the EARS battery. We defend that the translation and the adaptation process followed for the EARS test battery into European Portuguese was correctly conducted

  10. Battery cycling and calendar aging: year one testing results.

    Science.gov (United States)

    2016-07-01

    This report is meant to provide an update on the ongoing battery testing performed by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV batte...

  11. Potential use of battery packs from NCAP tested vehicles.

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Joshua; Orendorff, Christopher J.

    2013-10-01

    Several large electric vehicle batteries available to the National Highway Traffic Safety Administration are candidates for use in future safety testing programs. The batteries, from vehicles subjected to NCAP crashworthiness testing, are considered potentially damaged due to the nature of testing their associated vehicles have been subjected to. Criteria for safe shipping to Sandia is discussed, as well as condition the batteries must be in to perform testing work. Also discussed are potential tests that could be performed under a variety of conditions. The ultimate value of potential testing performed on these cells will rest on the level of access available to the battery pack, i.e. external access only, access to the on board monitoring system/CAN port or internal electrical access to the battery. Greater access to the battery than external visual and temperature monitoring would likely require input from the battery manufacturer.

  12. Hubble Space Telescope nickel-hydrogen battery testing: An update

    Science.gov (United States)

    Whitt, Thomas H.; Brewer, Jeffrey C.

    1995-02-01

    The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.

  13. The assessment of visuo-spatial neglect after acute stroke.

    OpenAIRE

    Stone, S P; Wilson, B; Wroot, A; Halligan, P W; Lange, L S; Marshall, J C; Greenwood, R J

    1991-01-01

    Forty four consecutive patients with acute hemispheric stroke and forty seven elderly controls with no neurological disease were assessed for visuo-spatial neglect, using a modified neglect test battery. Neglect was found to be equally common in patients with right hemisphere and left hemisphere stroke three days after stroke (72% versus 62%). It was more severe in those with a right hemisphere stroke and resolved more frequently in those with a left hemisphere stroke. The battery was validat...

  14. Development of a central auditory test battery for adults.

    NARCIS (Netherlands)

    Neijenhuis, C.A.M.; Stollman, M.H.P.; Snik, A.F.M.; Broek, P. van den

    2001-01-01

    There is little standardized test material in Dutch to document central auditory processing disorders (CAPDs). Therefore, a new central auditory test battery was composed and standardized for use with adult populations and older children. The test battery comprised seven tests (words in noise,

  15. Cell overcharge testing inside sodium metal halide battery

    Science.gov (United States)

    Frutschy, Kris; Chatwin, Troy; Bull, Roger

    2015-09-01

    Testing was conducted to measure electrical performance and safety of the General Electric Durathon™ E620 battery module (600 V class 20 kWh) during cell overcharge. Data gathered from this test was consistent with SAE Electric Vehicle Battery Abuse Testing specification J2464 [1]. After cell overcharge failure and 24 A current flow for additional 60 minutes, battery was then discharged at 7.5 KW average power to 12% state of charge (SOC) and recharged back to 100% SOC. This overcharging test was performed on two cells. No hydrogen chloride (HCl) gas was detected during front cell (B1) test, and small amount (6.2 ppm peak) was measured outside the battery after center cell (F13) overcharge. An additional overcharge test was performed per UL Standard 1973 - Batteries for Use in Light Electric Rail (LER) Applications and Stationary Applications[2]. With the battery at 11% SOC and 280 °C float temperature, an individual cell near the front (D1) was deliberately imbalanced by charging it to 62% SOC. The battery was then recharged to 100% SOC. In all three tests, the battery cell pack was stable and individual cell failure did not propagate to other cells. Battery discharge performance, charge performance, and electrical isolation were normal after all three tests.

  16. Development of a Valid Volleyball Skills Test Battery.

    Science.gov (United States)

    Bartlett, Jackie; And Others

    1991-01-01

    Describes the development of the North Carolina State University Volleyball Skills Test Battery which offers accurate measurement of three volleyball skills (serve, forearm pass, and set). When physical educators tested 313 students, the battery objectively measured their abilities, providing a gamelike means of teaching, testing, grouping, and…

  17. Relationship Between the Aviation Selection Test and a Psychomotor Battery

    National Research Council Canada - National Science Library

    Portman-Tiller, Claire

    1998-01-01

    ... test. The purpose of this study was to establish the relationship between the paper-and-pencil Aviation Selection Test Battery that is currently being used and a Computer-Based Performance Test (CBPT...

  18. Testing Conducted for Lithium-Ion Cell and Battery Verification

    Science.gov (United States)

    Reid, Concha M.; Miller, Thomas B.; Manzo, Michelle A.

    2004-01-01

    The NASA Glenn Research Center has been conducting in-house testing in support of NASA's Lithium-Ion Cell Verification Test Program, which is evaluating the performance of lithium-ion cells and batteries for NASA mission operations. The test program is supported by NASA's Office of Aerospace Technology under the NASA Aerospace Flight Battery Systems Program, which serves to bridge the gap between the development of technology advances and the realization of these advances into mission applications. During fiscal year 2003, much of the in-house testing effort focused on the evaluation of a flight battery originally intended for use on the Mars Surveyor Program 2001 Lander. Results of this testing will be compared with the results for similar batteries being tested at the Jet Propulsion Laboratory, the Air Force Research Laboratory, and the Naval Research Laboratory. Ultimately, this work will be used to validate lithium-ion battery technology for future space missions. The Mars Surveyor Program 2001 Lander battery was characterized at several different voltages and temperatures before life-cycle testing was begun. During characterization, the battery displayed excellent capacity and efficiency characteristics across a range of temperatures and charge/discharge conditions. Currently, the battery is undergoing lifecycle testing at 0 C and 40-percent depth of discharge under low-Earth-orbit (LEO) conditions.

  19. CONSTRUCTION AND STANDARDIZATION OF A BATTERY OF BRAILLE SKILL TESTS.

    Science.gov (United States)

    BOURGEAULT, STANLEY E.; WOODCOCK, RICHARD W.

    A BATTERY OF TESTS WAS DEVELOPED AND STANDARDIZED TO MEASURE MASTERY OF TWO BRAILLE CODES--THE GRADE 2 LITERARY CODE AND THE NEMETH CODE FOR MATHEMATICAL NOTATION. DESIGNATED AS THE "COLORADO BRAILLE BATTERY," THESE TESTS PROVIDED OBJECTIVE MEASUREMENT DATA REGARDING A STUDENT'S OVERALL DEVELOPMENT IN BRAILLE, AS WELL AS A MEANS OF…

  20. Magnetic moment test report for the model SAR 8108 battery

    Science.gov (United States)

    Ludwig, G. O.; Delbosco, E.; Montes, A.

    1988-05-01

    The procedures are described for determining the magnetic moment of the Eagle-Picher Model SAR 8108 Battery. The results of a test performed with this battery is presented. The experimental method used was to map the flux density field around the battery. The value of the magnetic moment was evaluated from the experimental data by a numerical procedure based on a spherical harmonic analysis and was found to be 0.050 + or - 0.005 A sq m.

  1. An Advanced HIL Simulation Battery Model for Battery Management System Testing

    DEFF Research Database (Denmark)

    Barreras, Jorge Varela; Fleischer, Christian; Christensen, Andreas Elkjær

    2016-01-01

    Developers and manufacturers of battery management systems (BMSs) require extensive testing of controller Hardware (HW) and Software (SW), such as analog front-end and performance of generated control code. In comparison with the tests conducted on real batteries, tests conducted on a state......-of-the-art hardware-in-the-loop (HIL) simulator can be more cost and time effective, easier to reproduce, and safer beyond the normal range of operation, especially at early stages in the development process or during fault insertion. In this paper, an HIL simulation battery model is developed for purposes of BMS...... testing on a commercial HIL simulator. A multicell electrothermal Li-ion battery (LIB) model is integrated in a system-level simulation. Then, the LIB system model is converted to C code and run in real time with the HIL simulator. Finally, in order to demonstrate the capabilities of the setup...

  2. Using Spatio-Temporal Data from Trail-Making Tests to Assess Neglect

    DEFF Research Database (Denmark)

    Hald, Kasper; Knoche, Hendrik

    2016-01-01

    We designed an app based on the Trail-Making Test for as- sessment and rehabilitation of hemi-spatial neglect. A ran- domized controlled trial with thirty-six participants showed that player performance in the game was significantly af- fected by their cognitive conditions verified by standard...... neuropsychological tests and the nature of their lesions. A mixed ANOVA revealed that the average time going from one target to the next was significantly affected by the inter- action of their neglect scores and the goal position relative to the side of their lesion. The group testing positive for ne- glect had...

  3. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  4. Visual neglect in posterior cortical atrophy

    Directory of Open Access Journals (Sweden)

    Andrade Katia

    2010-08-01

    Full Text Available Abstract Background In posterior cortical atrophy (PCA, there is a progressive impairment of high-level visual functions and parietal damage, which might predict the occurrence of visual neglect. However, neglect may pass undetected if not assessed with specific tests, and might therefore be underestimated in PCA. In this prospective study, we aimed at establishing the side, the frequency and the severity of visual neglect, visual extinction, and primary visual field defects in an unselected sample of PCA patients. Methods Twenty-four right-handed PCA patients underwent a standardized battery of neglect tests. Visual fields were examined clinically by the confrontation method. Results Sixteen of the 24 patients (66% had signs of visual neglect on at least one test, and fourteen (58% also had visual extinction or hemianopia. Five patients (21% had neither neglect nor visual field defects. As expected, left-sided neglect was more severe than right-sided neglect. However, right-sided neglect resulted more frequently in this population (29% than in previous studies on focal brain lesions. Conclusion When assessed with specific visuospatial tests, visual neglect is frequent in patients with PCA. Diagnosis of neglect is important because of its negative impact on daily activities. Clinicians should consider the routine use of neglect tests to screen patients with high-level visual deficits. The relatively high frequency of right-sided neglect in neurodegenerative patients supports the hypothesis that bilateral brain damage is necessary for right-sided neglect signs to occur, perhaps because of the presence in the right hemisphere of crucial structures whose damage contributes to neglect.

  5. Construction Of A Computerised Information-Processing Test Battery

    Directory of Open Access Journals (Sweden)

    Johann M. Schepers

    2002-09-01

    Full Text Available The primary goal of the study was to construct a computerised information-processing test battery to measure choice reaction time for up to and including six bits of information, to measure discrimination reaction time with regard to colour patterns and form patterns, to measure rate of information processing with regard to perceptual stimuli and conceptual reasoning, and to develop a suitable scoring system for the respective tests. The battery of tests was applied to 58 pilots. Opsomming Die hoofdoel van die studie was om ‘n gerekenariseerde inligtingverwerkingstoets-battery te konstrueer om keusereaksietyd tot en met ses bis inligting te meet, om diskriminasie-reaksietyd ten opsigte van kleurpatrone en vormpatrone te meet, om tempo van inligtingverwerking ten opsigte van perseptuele stimuli en konseptuele redenering te meet en om ‘n gepaste nasienstelsel vir die onderskeie toetse te ontwikkel. Die battery toetse is op 58 vlieëniers toegepas

  6. The Rose Bengal Test in human brucellosis: a neglected test for the diagnosis of a neglected disease.

    Directory of Open Access Journals (Sweden)

    Ramón Díaz

    Full Text Available Brucellosis is a highly contagious zoonosis affecting livestock and human beings. The human disease lacks pathognomonic symptoms and laboratory tests are essential for its diagnosis. However, most tests are difficult to implement in the areas and countries were brucellosis is endemic. Here, we compared the simple and cheap Rose Bengal Test (RBT with serum agglutination, Coombs, competitive ELISA, Brucellacapt, lateral flow immunochromatography for IgM and IgG detection and immunoprecipitation with Brucella proteins. We tested 208 sera from patients with brucellosis proved by bacteriological isolation, 20 contacts with no brucellosis, and 1559 sera of persons with no recent contact or brucellosis symptoms. RBT was highly sensitive in acute and long evolution brucellosis cases and this related to its ability to detect IgM, IgG and IgA, to the absence of prozones, and to the agglutinating activity of blocking IgA at the pH of the test. RBT was also highly specific in the sera of persons with no contact with Brucella. No test in this study outperformed RBT, and none was fully satisfactory in distinguishing contacts from infected patients. When modified to test serum dilutions, a diagnostic titer >4 in RBT resulted in 87.4% sensitivity (infected patients and 100% specificity (contacts. We discuss the limitations of serological tests in the diagnosis of human brucellosis, particularly in the more chronic forms, and conclude that simplicity and affordability of RBT make it close to the ideal test for small and understaffed hospitals and laboratories.

  7. Aging evaluation of class 1E batteries: Seismic testing

    Energy Technology Data Exchange (ETDEWEB)

    Edson, J.L. (EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1990-08-01

    This report presents the results of a seismic testing program on naturally aged class 1E batteries obtained from a nuclear plant. The testing program is a Phase 2 activity resulting from a Phase 1 aging evaluation of class 1E batteries in safety systems of nuclear power plants, performed previously as a part of the US Nuclear Regulatory Commission's Nuclear Plant Aging Research Program and reported in NUREG/CR-4457. The primary purpose of the program was to evaluate the seismic ruggedness of naturally aged batteries to determine if aged batteries could have adequate electrical capacity, as determined by tests recommended by IEEE Standards, and yet have inadequate seismic ruggedness to provide needed electrical power during and after a safe shutdown earthquake (SSE) event. A secondary purpose of the program was to evaluate selected advanced surveillance methods to determine if they were likely to be more sensitive to the aging degradation that reduces seismic ruggedness. The program used twelve batteries naturally aged to about 14 years of age in a nuclear facility and tested them at four different seismic levels representative of the levels of possible earthquakes specified for nuclear plants in the United States. Seismic testing of the batteries did not cause any loss of electrical capacity. 19 refs., 29 figs., 7 tabs.

  8. A differential approach to microcomputer test battery development and implementation

    Science.gov (United States)

    Kennedy, R. S.; Baltzley, D. R.; Osteen, M. K.; Turnage, J. J.

    1988-01-01

    The present microcomputer-based performance test battery emphasizes psychometric theory and utility for repeated-measures applications during extended exposure to various environmental stressors. In the menu that has been defined at the current state of this system's development, there are more than 30 'qualified' mental tests which stabilize in less than 10 min and possess test-retest reliabilities greater than 0.7 for a three-minute test/work period. The battery encompasses tests of cognition, information processing, psychomotor skill, memory, mood, etc. Several of the tests have demonstrated sensitivity to chemoradiotherapy, sleep loss, hypoxia, amphetamines, thermal stress, sensory deprivation, altitude, fatigue, and alcohol use. Recommendations are presented for 6-, 12-, and 22-min batteries.

  9. A test battery measuring auditory capabilities of listening panels

    DEFF Research Database (Denmark)

    Ghani, Jody; Ellermeier, Wolfgang; Zimmer, Karin

    2005-01-01

    a battery of tests covering a larger range of auditory capabilities in order to assess individual listeners. The format of all tests is kept as 'objective' as possible by using a three-alternative forced-choice paradigm in which the subject must choose which of the sound samples is different, thus keeping...... the instruction to the subjects simple and common for all tests. Both basic (e.g. frequency discrimination) and complex (e.g. profile analysis) psychoacoustic tests are covered in the battery and a threshold of discrimination or detection is obtained for each test. Data were collected on 24 listeners who had been...... recruited for participation in an expert listening panel for evaluating the sound quality of hi-fi audio systems. The test battery data were related to the actual performance of the listeners when judging the degradation in quality produced by audio codecs....

  10. Overview of PNGV Battery Development and Test Programs

    Energy Technology Data Exchange (ETDEWEB)

    Motloch, Chester George; Murphy, Timothy Collins; Sutula, Raymond; Miller, Ted J.

    2002-02-01

    Affordable, safe, long-lasting, high-power batteries are requisites for successful commercialization of hybrid electric vehicles. The U.S. Department of Energy’s Office of Advance Automotive Technologies and the Partnership for a New Generation of Vehicles are funding research and development programs to address each of these issues. An overview of these areas is presented along with a summary of battery development and test programs, as well as recent performance data from several of these programs.

  11. A test battery related to ergonomics of protective clothing

    NARCIS (Netherlands)

    Havenith, G.; Heus, R.

    2004-01-01

    Specialised protective clothing, such as that worn by firefighters, is usually tested only to standards which give requirements for the materials used (e.g. EN469). However,this testing often neglects the effect the manufacturing process of the garment has on the material properties,the effects of

  12. Test Report : GS Battery, EPC power HES RESCU

    Energy Technology Data Exchange (ETDEWEB)

    Rose, David Martin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schenkman, Benjamin L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Borneo, Daniel R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-10-01

    The Department of Energy Office of Electricity (DOE/OE), Sandia National Laboratories (SNL) and the Base Camp Integration Lab (BCIL) partnered together to incorporate an energy storage system into a microgrid configured Forward Operating Base to reduce the fossil fuel consumption and to ultimately save lives. Energy storage vendors will be sending their systems to SNL Energy Storage Test Pad (ESTP) for functional testing and then to the BCIL for performance evaluation. The technologies that will be tested are electro-chemical energy storage systems comprising of lead acid, lithium-ion or zinc-bromide. GS Battery and EPC Power have developed an energy storage system that utilizes zinc-bromide flow batteries to save fuel on a military microgrid. This report contains the testing results and some limited analysis of performance of the GS Battery, EPC Power HES RESCU.

  13. Do Neglect Assessments Detect Neglect Differently?

    Science.gov (United States)

    Woodbury, Michelle L.

    2017-01-01

    OBJECTIVE. We determined whether various assessment tools detect neglect differently by administering a battery of assessments to people with stroke. METHOD. We conducted a case series study and administered five neglect assessments (paper-and-pencil, functional, virtual reality) to participants poststroke. RESULTS. Twelve participants (6 men, 6 women) with stroke completed the assessment battery, which required approximately 2 hr to administer (over one to two sessions). All participants demonstrated neglect on three or more assessments. Functional assessments and the virtual reality assessment detected neglect more frequently than the paper-and-pencil assessments. Participants performed differently on the paper-and-pencil assessments and functional assessments. CONCLUSION. Because neglect is complex, detection may depend largely on the assessment administered. PMID:28422631

  14. Battery Technology Life Verification Test Manual Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen

    2012-12-01

    The purpose of this Technology Life Verification Test (TLVT) Manual is to help guide developers in their effort to successfully commercialize advanced energy storage devices such as battery and ultracapacitor technologies. The experimental design and data analysis discussed herein are focused on automotive applications based on the United States Advanced Battery Consortium (USABC) electric vehicle, hybrid electric vehicle, and plug-in hybrid electric vehicle (EV, HEV, and PHEV, respectively) performance targets. However, the methodology can be equally applied to other applications as well. This manual supersedes the February 2005 version of the TLVT Manual (Reference 1). It includes criteria for statistically-based life test matrix designs as well as requirements for test data analysis and reporting. Calendar life modeling and estimation techniques, including a user’s guide to the corresponding software tool is now provided in the Battery Life Estimator (BLE) Manual (Reference 2).

  15. Battery Test Manual For Electric Vehicles, Revision 3

    Energy Technology Data Exchange (ETDEWEB)

    Christophersen, Jon P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Electric Vehicles (EV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for EVs. However, it does share some methods described in the previously published battery test manual for plug-in hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Chul Bae of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).

  16. 24-hour assessment of performance on a palmtop computer: Validating a self-constructed test battery

    NARCIS (Netherlands)

    Varkevisser, M.; Kerkhof, G.A.

    2003-01-01

    A test battery was constructed on a palmtop computer for ambulatory purposes. This study explored whether the test battery could assess circadian rhythmicity underconstant routine conditions. Performance, body temperature, and subjective sleepiness of 12 healthy subjects were measured. The test

  17. Exploratory battery technology development and testing report for 1989

    Energy Technology Data Exchange (ETDEWEB)

    Magnani, N.J.; Diegle, R.B.; Braithwaite, J.W.; Bush, D.M.; Freese, J.M.; Akhil, A.A.; Lott, S.E.

    1990-12-01

    Sandia National Laboratories, Albuquerque, has been designated as Lead Center for the Exploratory Battery Technology Development and Testing Project, which is sponsored by the US Department of Energy's Office of Energy Storage and Distribution. In this capacity, Sandia is responsible for the engineering development of advanced rechargeable batteries for both mobile and stationary energy storage applications. This report details the technical achievements realized in pursuit of the Lead Center's goals during calendar year 1989. 4 refs., 84 figs., 18 tabs.

  18. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...... ratio. The dc-dc converter controls the battery charge/discharge current while the grid converter controls the common dc-link voltage and the grid current. The applied control structures and the hardware implementation of both converters are presented, together with their interaction. Experimental...

  19. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...

  20. Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Lee Kenneth [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-03-01

    This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

  1. Fire Tests on E-vehicle Battery Cells and Packs.

    Science.gov (United States)

    Sturk, David; Hoffmann, Lars; Ahlberg Tidblad, Annika

    2015-01-01

    The purpose of this study was to investigate the effects of abuse conditions, including realistic crash scenarios, on Li ion battery systems in E-vehicles in order to develop safe practices and priorities when responding to accidents involving E-vehicles. External fire tests using a single burning item equipment were performed on commercial Li ion battery cells and battery packs for electric vehicle (E-vehicle) application. The 2 most common battery cell technologies were tested: Lithium iron phosphate (LFP) and mixed transition metal oxide (lithium nickel manganese cobalt oxide, NMC) cathodes against graphite anodes, respectively. The cell types investigated were "pouch" cells, with similar physical dimensions, but the NMC cells have double the electric capacity of the LFP cells due to the higher energy density of the NMC chemistry, 7 and 14 Ah, respectively. Heat release rate (HRR) data and concentrations of toxic gases were acquired by oxygen consumption calorimetry and Fourier transform infrared spectroscopy (FTIR), respectively. The test results indicate that the state of charge (SOC) affects the HRR as well as the amount of toxic hydrogen fluoride (HF) gas formed during combustion. A larger number of cells increases the amount of HF formed per cell. There are significant differences in response to the fire exposure between the NMC and LFP cells in this study. The LFP cells generate a lot more HF per cell, but the overall reactivity of the NMC cells is higher. However, the total energy released by both batteries during combustion was independent of SOC, which indicates that the electric energy content of the test object contributes to the activation energy of the thermal and heat release process, whereas the chemical energy stored in the materials is the main source of thermal energy in the batteries. The results imply that it is difficult to draw conclusions about higher order system behavior with respect to HF emissions based on data from tests on single

  2. Adaptation of the AAHPERD test battery for institutionalized older adults.

    Directory of Open Access Journals (Sweden)

    Tânia R. Bertoldo Benedetti

    2013-12-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2014v16n1p1 The American Alliance for Health, Physical Education, Recreation and Dance (AAHPERD test battery assesses the functional fitness of older adults in five motor fitness tests. The objective of this study was to adapt and test the AAHPERD in institutionalized older adults and to define normative values of functional fitness for this population. A pilot test was conducted on older adults living in nursing homes, which confirmed the need to adapt the flexibility and aerobic endurance tests. The first test was redesigned so that the elderly person did not have to sit on the floor. The second test was changed from a half-mile to a 6-minute walk. The tests were adapted and tested in a sample of 92 older adults from six long-term care homes. The successful application of the AAHPERD adapted for older adults living in nursing homes permitted the establishment of normative values for the five motor tests. The adapted version of the AAHPERD is an easily applied, low-cost tool of low risk since it was adapted to the physical and functional conditions of institutionalized older adults. This physical test battery will contribute to the evaluation of older adults and exercise prescription.

  3. A standardized test battery for the study of synesthesia.

    Science.gov (United States)

    Eagleman, David M; Kagan, Arielle D; Nelson, Stephanie S; Sagaram, Deepak; Sarma, Anand K

    2007-01-15

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research.

  4. Construction and testing of coin cells of lithium ion batteries.

    Science.gov (United States)

    Kayyar, Archana; Huang, Jiajia; Samiee, Mojtaba; Luo, Jian

    2012-08-02

    Rechargeable lithium ion batteries have wide applications in electronics, where customers always demand more capacity and longer lifetime. Lithium ion batteries have also been considered to be used in electric and hybrid vehicles or even electrical grid stabilization systems. All these applications simulate a dramatic increase in the research and development of battery materials, including new materials, doping, nanostructuring, coatings or surface modifications and novel binders. Consequently, an increasing number of physicists, chemists and materials scientists have recently ventured into this area. Coin cells are widely used in research laboratories to test new battery materials; even for the research and development that target large-scale and high-power applications, small coin cells are often used to test the capacities and rate capabilities of new materials in the initial stage. In 2010, we started a National Science Foundation (NSF) sponsored research project to investigate the surface adsorption and disordering in battery materials (grant no. DMR-1006515). In the initial stage of this project, we have struggled to learn the techniques of assembling and testing coin cells, which cannot be achieved without numerous help of other researchers in other universities (through frequent calls, email exchanges and two site visits). Thus, we feel that it is beneficial to document, by both text and video, a protocol of assembling and testing a coin cell, which will help other new researchers in this field. This effort represents the "Broader Impact" activities of our NSF project, and it will also help to educate and inspire students. In this video article, we document a protocol to assemble a CR2032 coin cell with a LiCoO2 working electrode, a Li counter electrode, and (the mostly commonly used) polyvinylidene fluoride (PVDF) binder. To ensure new learners to readily repeat the protocol, we keep the protocol as specific and explicit as we can. However, it is important

  5. Microprocessor controlled pulse charge and testing of batteries

    International Nuclear Information System (INIS)

    Kerezov, A.; Gishin, S.; Ivanov, Ratcho; Savov, S.

    2002-01-01

    The principle of the developed new method for pulse charge of batteries with microprocessor control of the electrochemical processes is the use of current pulses with microprocessor control of the period and the amplitude according to the dynamically changing state of the electrochemical system. In order to realize the method described above a programmable current source was developed. It is connected with a Personal Computer via RS232 standard serial interface in order to control the electrochemical processes. The parameters to be set, the graphical presentation of the pulse current and tension, the used quantity of electricity and electrical energy for every pulse and for the process as a hole are shown on the PC display. In order to test dry-charged and wet-charged batteries a specialized current generator was developed. It is connected also with a Personal Computer via R5232 standard serial interface in order to con-trol the testing of the starting capability of the batteries according to the requirements of the Bulgarian State Standard Ell 60095-1. (Author)

  6. The DiaNAH test battery for visual perceptual disorders : Validity and efficacy in rehabilitation practice

    NARCIS (Netherlands)

    Heutink, Jochem; de Vries, Stefanie; Melis, Bart; Vrijling, Anne; Tucha, Oliver

    2018-01-01

    We developed the DiaNAH test battery for the screening of mid-level and higher-order visual perceptual disorders in clinical practice. The DiaNAH battery comprises 11 different tests and can be administered in 30-60 minutes. Important feature of the DiaNAH battery is that it is administered on a 24”

  7. Novel Field Test Equipment for Lithium-Ion Batteries in Hybrid Electrical Vehicle Applications

    Directory of Open Access Journals (Sweden)

    Goran Lindbergh

    2011-04-01

    Full Text Available Lifetime testing of batteries for hybrid-electrical vehicles (HEV is usually performed in the lab, either at the cell, module or battery pack level. Complementary field tests of battery packs in vehicles are also often performed. There are, however, difficulties related to field testing of battery-packs. Some examples are cost issues and the complexity of continuously collecting battery performance data, such as capacity fade and impedance increase. In this paper, a novel field test equipment designed primarily for lithium-ion battery cell testing is presented. This equipment is intended to be used on conventional vehicles, not hybrid vehicles, as a cheaper and faster field testing method for batteries, compared to full scale HEV testing. The equipment emulates an HEV environment for the tested battery cell by using real time vehicle sensor information and the existing starter battery as load and source. In addition to the emulated battery cycling, periodical capacity and pulse testing capability are implemented as well. This paper begins with presenting some background information about hybrid electrical vehicles and describing the limitations with today’s HEV battery testing. Furthermore, the functionality of the test equipment is described in detail and, finally, results from verification of the equipment are presented and discussed.

  8. An alternative test battery in detecting ocular irritancy of agrochemicals.

    Science.gov (United States)

    Tavaszi, J; Budai, P; Pálovics, A; Kismányoki, A

    2008-01-01

    Using animals in toxicological screening is a controversial issue. To get knowledge about eye irritation, recently only the in vivo Draize-test is accepted, which is one of the most criticized methods because of the injuries inflicted on the test animals. In recent years various in vitro methods have been developed to replace the primary irritation test. Most of these tests are in process of validation. The Draize rabbit eye test, or some modification of this test is essentially the only method for determining ocular irritation that is accepted by authorities. Several in vitro methods have been used to investigate the toxicity of potential eye irritants with the aim of replacing in vitro eye irritation testing. This study reports the results of an alternative approach for predicting irritation potential of agrochemicals. The approach was a two-stage test battery in vitro. The first stage was a cytotoxicity test, the MTT assay. The second stage was the HET-CAM test. The chick chorioallantoic membrane (CAM), being a connective tissue sheet with a visible blood supply, has been proposed as a substrate to identify the eye irritation potential of chemicals. During the HET-CAM test the chemicals are placed directly onto the chorioallantoic membrane. The changes of the vascular injury (haemorrhage, lysis or coagulation) are indications of the potential of the chemical to damage mucous membranes in vivo. MTT assay is a simple method to determine the viability of cells in the presence of a chemical. Cells are cultured with several concentrations of a substance or product, then the ratio of cell destruction is determined. LCC50 (concentration lethal for the 50 % of the cells) is assessed. This is in correlation of the eye irrigative potential of the chemical. In our studies comparative screening was performed with 6 agrochemicals to establish parallel data on alternative test battery (HET-CAM, MTT) and in vivo (Draize) results. In most cases, this study showed a good

  9. Factorial Structure of Cognitive Activity Using a Neuropsychological Test Battery

    Directory of Open Access Journals (Sweden)

    A. Ardila

    1994-01-01

    Full Text Available A general neuropsychological test battery was assembled and individually given to a 98-subject sample, aged 11–12 years old. The battery included some basic and common tests routinely used in the evaluation of language, memory, spatial abilities, concept formation, and praxic abilities. Twenty-five different scores were calculated. A factor analysis with varimax rotation disclosed nine different factors, accounting for about 70% of the variance. Factor I was measured by a Sequential Verbal Memory test and Verbal Fluency subtests (“verbal factor”. Factor II was measured by the Wechsler Memory Scale Visual Memory subtests (immediate and delayed reproduction, and the Rey-Osterrieth Complex Figure (copy and immediate reproduction (“non-verbal memory and constructional factor”. Factor III was measured by the WMS Logical Memory subtests (immediate and delayed; “verbal memory factor”. Factor IV was associated with fine movements (tapping subtests, right and left hand; “fine movements factor”. Factor V was specially measured by the Information subtest of the WMS and the Boston Naming Test (“verbal knowledge”. Factor VI represented a “praxic ability factor” (ideomotor praxis tests. Delayed Associative Learning subtest measured Factor VII; and Digits measured Factor VIII. Factor IX was a “mental control factor” (Mental Control subtest of the Wechsler Memory Scale. The implications of these results to theories relating to the structure of cognitive activity are discussed.

  10. Clinical assessment of hemispatial neglect: Evaluation of different measures and dimensions

    NARCIS (Netherlands)

    Lindell, A.B.; Jalas, M.J.; Tenovuo, O.; Brunila, T.; Voeten, M.J.M.; Hämäläinen, H.

    2007-01-01

    The multidimensional nature of the neglect syndrome constitutes a challenge for clinical assessments. This study evaluates the sensitivity of different clinical measures to detect neglect and explores ways to evaluate the diversity of the syndrome in a clinical sample. An extensive battery of tests

  11. A Microcomputer Test Battery for Evaluating the Effects of Neuropsychiatric Treatment Interventions

    Science.gov (United States)

    Krynicki, Victor E.; MacKenty, Edmund; Itil, Turan M.

    1979-01-01

    A microcomputer based battery of neuropsychiatric tests is described. This battery is capable of gathering a large amount of information in a cost-effective way. The tests included are: a Learning Paradigm, a Memory Scanning Test, a Rapid Automatized Naming Test, the Continuous Performance Test, and a Selective Attention Test. The background of each test is described. Results of the administration of this battery are written out by means of a password-controlled Output program. A case example is presented, in which the battery was used to establish the effect of a very low dosage of medication on memory functions in a learning disabled/MBD child.

  12. A test battery measuring auditory capabilities of listening panels

    DEFF Research Database (Denmark)

    Ghani, Jody; Ellermeier, Wolfgang; Zimmer, Karin

    2005-01-01

    While the literature stresses the importance of expert panels and of training in evaluating sound-quality attributes, the abilities of experts have typically only been investigated for a very limited range of tasks (e.g. naming timbral qualities). It is therefore the aim of this study to develop ...... recruited for participation in an expert listening panel for evaluating the sound quality of hi-fi audio systems. The test battery data were related to the actual performance of the listeners when judging the degradation in quality produced by audio codecs....

  13. The ecological assessment of unilateral neglect.

    Science.gov (United States)

    Azouvi, Philippe

    2017-06-01

    Conventional paper-and-pencil tests of unilateral neglect are of limited ecological validity. To address this issue, a number of assessment procedures have been proposed to provide clinicians and researchers with more ecologically valid assessments of unilateral neglect, which may be useful to plan rehabilitation and to measure the generalization of the effects of rehabilitation to daily life. We present here an overview of the different assessment measures available in the literature. The most widely used scales are the Behavioural Inattention Test (BIT), the semi-structured scales for assessment of personal and extra-personal neglect, the Subjective Neglect Questionnaire, the Baking Tray Task, the wheelchair obstacle course, the ADL-based neglect battery, and the Catherine Bergego Scale (CBS). The CBS is probably, to date, the most widely used behavioural assessment instrument for unilateral neglect. It has been found to be reliable, valid, and sensitive to change during rehabilitation. It also enables the assessment of awareness of the consequences of unilateral neglect in daily life skills. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Development of an auditory test battery for young children: a pilot study.

    NARCIS (Netherlands)

    Stollman, M.H.P.; Neijenhuis, C.A.M.; Jansen, S.; Simkens, H.M.F.; Snik, A.F.M.; Broek, P. van den

    2004-01-01

    This article describes the development and results of a pilot study with a recently developed auditory test battery for 4-6-year-old Dutch children. The test battery consisted of a sustained auditory attention (SAA) test, a dichotic words (DW) test, a binaural masking-level difference (BMLD) test,

  15. Development and Validation of the Cognition Test Battery for Spaceflight

    Science.gov (United States)

    Basner, Mathias; Savitt, Adam; Moore, Tyler M.; Port, Allison M.; McGuire, Sarah; Ecker, Adrian J.; Nasrini, Jad; Mollicone, Daniel J.; Mott, Christopher M.; McCann, Thom; Dinges, David F.; Gur, Ruben C.

    2015-01-01

    Background Sustained high-level cognitive performance is of paramount importance for the success of space missions, which involve environmental, physiological and psychological stressors that may affect brain functions. Despite subjective symptom reports of cognitive fluctuations in spaceflight, the nature of neurobehavioral functioning in space has not been clarified. Methods We developed a computerized cognitive test battery (Cognition) that has sensitivity to multiple cognitive domains and was specifically designed for the high-performing astronaut population. Cognition consists of 15 unique forms of 10 neuropsychological tests that cover a range of cognitive domains including emotion processing, spatial orientation, and risk decision making. Cognition is based on tests known to engage specific brain regions as evidenced by functional neuroimaging. Here we describe the first normative and acute total sleep deprivation data on the Cognition test battery as well as several efforts underway to establish the validity, sensitivity, feasibility, and acceptability of Cognition. Results Practice effects and test-retest variability differed substantially between the 10 Cognition tests, illustrating the importance of normative data that both reflect practice effects and differences in stimulus set difficulty in the population of interest. After one night without sleep, medium to large effect sizes were observed for 3 of the 10 tests addressing vigilant attention (Cohen’s d=1.00), cognitive throughput (d=0.68), and abstract reasoning (d=0.65). Conclusions In addition to providing neuroimaging-based novel information on the effects of spaceflight on a range of cognitive functions, Cognition will facilitate comparing the effects of ground-based analogs to spaceflight, increase consistency across projects, and thus enable meta-analyses. PMID:26564759

  16. Development and Validation of the Cognition Test Battery for Spaceflight.

    Science.gov (United States)

    Basner, Mathias; Savitt, Adam; Moore, Tyler M; Port, Allison M; McGuire, Sarah; Ecker, Adrian J; Nasrini, Jad; Mollicone, Daniel J; Mott, Christopher M; McCann, Thom; Dinges, David F; Gur, Ruben C

    2015-11-01

    Sustained high-level cognitive performance is of paramount importance for the success of space missions, which involve environmental, physiological, and psychological stressors that may affect brain functions. Despite subjective symptom reports of cognitive fluctuations in spaceflight, the nature of neurobehavioral functioning in space has not been clarified. We developed a computerized cognitive test battery (Cognition) that has sensitivity to multiple cognitive domains and was specifically designed for the high-performing astronaut population. Cognition consists of 15 unique forms of 10 neuropsychological tests that cover a range of cognitive domains, including emotion processing, spatial orientation, and risk decision making. Cognition is based on tests known to engage specific brain regions as evidenced by functional neuroimaging. Here we describe the first normative and acute total sleep deprivation data on the Cognition test battery as well as several efforts underway to establish the validity, sensitivity, feasibility, and acceptability of Cognition. Practice effects and test-retest variability differed substantially between the 10 Cognition tests, illustrating the importance of normative data that both reflect practice effects and differences in stimulus set difficulty in the population of interest. After one night without sleep, medium to large effect sizes were observed for 3 of the 10 tests addressing vigilant attention (Cohen's d = 1.00), cognitive throughput (d = 0.68), and abstract reasoning (d = 0.65). In addition to providing neuroimaging-based novel information on the effects of spaceflight on a range of cognitive functions, Cognition will facilitate comparing the effects of ground-based analogues to spaceflight, increase consistency across projects, and thus enable meta-analyses.

  17. Battery lifetime prediction by pattern recognition. Application to lead-acid battery life-cycling test data

    Science.gov (United States)

    Perone, Sam P.; Spindler, W. C.

    1984-09-01

    A novel approach to battery lifetime prediction has been evaluated by application to life-cycling data collected for 108 ESB EV-106 6-V. golf cart batteries (tests conducted by TRW for NASA-Lewis). This approach utilized computerized pattern recognition methods to examine initial cycling measurements and classify each battery into one of two classes: "long-lived" or "short-lived". The classifier program was based on either a linear discriminant or nearest neighbor analysis of a training set consisting of: each member of the EV battery set which had failed; the relative lifetime of each member — normalized with respect to test conditions; and a set of "features" based on measurements of the initial behavior. The raw data set included capacity trends over the first 8 or 9 cycles and records of specific gravity and water-added for each cell after initial cycling. Features defined from these raw data included the individual data items as well as transformations and combinations of these data. All features were represented as standardized variables. It was shown that lifetime prediction of batteries within the two categories defined could be made with about 87% accuracy. It is concluded that for a similarly-manufactured battery set, relative lifetime prediction could be based on initial measurements of the same type examined here.

  18. Making Sense of Listening: The IMAP Test Battery

    Science.gov (United States)

    2010-01-01

    The ability to hear is only the first step towards making sense of the range of information contained in an auditory signal. Of equal importance are the abilities to extract and use the information encoded in the auditory signal. We refer to these as listening skills (or auditory processing AP). Deficits in these skills are associated with delayed language and literacy development, though the nature of the relevant deficits and their causal connection with these delays is hotly debated. When a child is referred to a health professional with normal hearing and unexplained difficulties in listening, or associated delays in language or literacy development, they should ideally be assessed with a combination of psychoacoustic (AP) tests, suitable for children and for use in a clinic, together with cognitive tests to measure attention, working memory, IQ, and language skills. Such a detailed examination needs to be relatively short and within the technical capability of any suitably qualified professional. Current tests for the presence of AP deficits tend to be poorly constructed and inadequately validated within the normal population. They have little or no reference to the presenting symptoms of the child, and typically include a linguistic component. Poor performance may thus reflect problems with language rather than with AP. To assist in the assessment of children with listening difficulties, pediatric audiologists need a single, standardized child-appropriate test battery based on the use of language-free stimuli. We present the IMAP test battery which was developed at the MRC Institute of Hearing Research to supplement tests currently used to investigate cases of suspected AP deficits. IMAP assesses a range of relevant auditory and cognitive skills and takes about one hour to complete. It has been standardized in 1500 normally-hearing children from across the UK, aged 6-11 years. Since its development, it has been successfully used in a number of large scale

  19. Recovery of personal neglect.

    Science.gov (United States)

    Iosa, Marco; Guariglia, Cecilia; Matano, Alessandro; Paolucci, Stefano; Pizzamiglio, Luigi

    2016-12-01

    Extrapersonal unilateral spatial neglect after stroke is associated to a poor rehabilitation outcome. Minor attention has been paid to the recovery of personal neglect, to its relationship with the recovery of extrapersonal neglect and of independency in activities of daily living. The present study aims at evaluating whether there is an association between recovery of extrapersonal and personal neglect. The secondary aim was to investigate if personal neglect may affect the effectiveness of neurorehabilitation in patients with subacute stroke. Observational study. Neurorehabilitation Hospital in Rome, Italy, inpatients. A sample of 49 patients with unilateral spatial neglect resulting from right ischemic cerebral infarction was enrolled in this study, divided into three subgroups according to the presence and the degree of personal neglect, and evaluated pre and postneurorehabilitation. Personal neglect was evaluated using Zoccolotti and Judica's Scale, extrapersonal neglect using Letter Cancellation Test, Barrage Test, Sentence Reading Test and Wundt-Jastrow Area Illusion Test. Barthel Index (BI), Rivermead Mobility Index, and Canadian Neurological Scale were also administered. Results showed the following: 1) recovery of personal neglect was not significantly correlated with that of extrapersonal neglect, despite both the disorders were ameliorated after a "non-specific" rehabilitation treatment; 2) personal neglect per se was not an additional negative prognostic factor in the rehabilitation findings. Our results suggested that the recoveries of the two types of neglect are independent from each other, and that the presence of personal neglect does not imply significant additional problems to the functional outcomes. Our study highlighted the need of novel tools to assess the presence and to improve the recovery of personal neglect.

  20. Test and Evaluation of MK 37 Torpedo Batteries.

    Science.gov (United States)

    1979-12-01

    specifications and to estimate, in so far as it was possible, the life expectancy of the exercise battery (1). The manufacturer was Eagle Picher of... batteries were interpreted from the engineering drawings supplied by Eagle Picher (2). The full-size exercise battery is charged at a constant 2 A...by the manufacturer, Eagle Picher (2). Details will be elaborated below. UNCLASSIFIED UNCLASSIFIED 3 Fig. 1A: Exercise Bcztte2iy for MX 317 Torpedo

  1. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  2. Development of a Test Battery to Select Navy Recruiters

    National Research Council Canada - National Science Library

    Penney, Lisa M; Borman, Walter C; Bearden, Ronald M

    2007-01-01

    .... the students were administered a trial predictor battery while at the school, and performance ratings and production data were collected after participants had been assigned to recruiting duty...

  3. The field-testing of a novel integrated mapping protocol for neglected tropical diseases.

    Directory of Open Access Journals (Sweden)

    Sonia Pelletreau

    2011-11-01

    Full Text Available BACKGROUND: Vertical control and elimination programs focused on specific neglected tropical diseases (NTDs can achieve notable success by reducing the prevalence and intensity of infection. However, many NTD-endemic countries have not been able to launch or scale-up programs because they lack the necessary baseline data for planning and advocacy. Each NTD program has its own mapping guidelines to collect missing data. Where geographic overlap among NTDs exists, an integrated mapping approach could result in significant resource savings. We developed and field-tested an innovative integrated NTD mapping protocol (Integrated Threshold Mapping (ITM Methodology for lymphatic filariasis (LF, trachoma, schistosomiasis and soil-transmitted helminths (STH. METHODOLOGY/PRINCIPAL FINDINGS: The protocol is designed to be resource-efficient, and its specific purpose is to determine whether a threshold to trigger public health interventions in an implementation unit has been attained. The protocol relies on World Health Organization (WHO recommended indicators in the disease-specific age groups. For each disease, the sampling frame was the district, but for schistosomiasis, the sub-district rather than the ecological zone was used. We tested the protocol by comparing it to current WHO mapping methodologies for each of the targeted diseases in one district each in Mali and Senegal. Results were compared in terms of public health intervention, and feasibility, including cost. In this study, the ITM methodology reached the same conclusions as the WHO methodologies regarding the initiation of public health interventions for trachoma, LF and STH, but resulted in more targeted intervention recommendations for schistosomiasis. ITM was practical, feasible and demonstrated an overall cost saving compared with the standard, non-integrated, WHO methodologies. CONCLUSIONS/SIGNIFICANCE: This integrated mapping tool could facilitate the implementation of much

  4. Age effects and normative data on a Dutch test battery for auditory processing disorders.

    NARCIS (Netherlands)

    Neijenhuis, C.A.M.; Snik, A.F.M.; Priester, G.; Kordenoordt, S. van; Broek, P. van den

    2002-01-01

    A test battery compiled to diagnose auditory processing disorders (APDs) in an adult population was used on a population of 9-16-year-old children. The battery consisted of eight tests (words -in noise, filtered speech, binaural fusion, dichotic digits, frequency and duration patterns, backward

  5. Modified performance test of vented lead acid batteries for stationary applications

    International Nuclear Information System (INIS)

    Uhlir, K.W.; Fletcher, R.J.

    1995-01-01

    The concept of a modified performance test for vented lead acid batteries in stationary applications has been developed by the IEEE Battery Working Group. The modified performance test is defined as a test in the ''as found'' condition of the battery capacity and its ability to provide a high rate, short duration load (usually the highest rate of the duty cycle) that will confirm the battery's ability to meet the critical period of the load duty cycle, in addition to determining its percentage of rated capacity. This paper will begin by reviewing performance and service test requirements and concerns associated with both types of tests. The paper will then discuss the rationale for developing a modified performance test along with the benefits that can be derived from performing a modified performance test in lieu of a capacity test and/or a service test. The paper will conclude with an example on how to apply a modified performance test and test acceptance criteria

  6. Charge retention test experiences on Hubble Space Telescope nickel-hydrogen battery cells

    Science.gov (United States)

    Nawrocki, Dave E.; Driscoll, J. R.; Armantrout, J. D.; Baker, R. C.; Wajsgras, H.

    1993-02-01

    The Hubble Space Telescope (HST) nickel-hydrogen battery module was designed by Lockheed Missile & Space Co (LMSC) and manufactured by Eagle-Picher Ind. (EPI) for the Marshall Space Flight Center (MSFC) as an Orbital Replacement Unit (ORU) for the nickel-cadmium batteries originally selected for this low earth orbit mission. The design features of the HST nickel hydrogen battery are described and the results of an extended charge retention test are summarized.

  7. Batteries

    Directory of Open Access Journals (Sweden)

    Yang Lijuan

    2016-01-01

    Full Text Available Fe3O4/carbon microspheres (Fe3O4/C were prepared by a facile hydrothermal reaction using cellulose and ferric trichloride as precursors. The resultant composite spheres have been investigated as anode materials for the lithium-ion batteries, and they show high capacity and good cycle stability (830mAhg−1 at a current density of 0.1C up to 70 cycles, as well as enhanced rate capability. The excellent electrochemical performance is attributed to the high structural stability and high rate of ionic/electronic conduction arising from the porous character and the synergetic effect of the carbon coated Fe3O4 structure and conductive carbon coating.

  8. Development and Testing of an UltraBattery-Equipped Honda Civic Hybrid

    Energy Technology Data Exchange (ETDEWEB)

    Sally (Xiaolei) Sun; Tyler Gray; Pattie Hovorka; Jeffrey Wishart; Donald Karner; James Francfort

    2012-08-01

    The UltraBattery Retrofit Project DP1.8 and Carbon Enriched Project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy and the Advanced Lead Acid Battery Consortium (ALABC), are established to demonstrate the suitability of advanced lead battery technology in hybrid electrical vehicles (HEVs). A profile, termed the “Simulated Honda Civic HEV Profile” (SHCHEVP) has been developed in Project DP1.8 in order to provide reproducible laboratory evaluations of different battery types under real-world HEV conditions. The cycle is based on the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles and simulates operation of a battery pack in a Honda Civic HEV. One pass through the SHCHEVP takes 2,140 seconds and simulates 17.7 miles of driving. A complete nickel metal hydride (NiMH) battery pack was removed from a Honda Civic HEV and operated under SHCHEVP to validate the profile. The voltage behavior and energy balance of the battery during this operation was virtually the same as that displayed by the battery when in the Honda Civic operating on the dynamometer under the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles, thus confirming the efficacy of the simulated profile. An important objective of the project has been to benchmark the performance of the UltraBatteries manufactured by both Furukawa Battery Co., Ltd., Japan (Furakawa) and East Penn Manufacturing Co., Inc. (East Penn). Accordingly, UltraBattery packs from both Furakawa and East Penn have been characterized under a range of conditions. Resistance measurements and capacity tests at various rates show that both battery types are very similar in performance. Both technologies, as well as a standard lead-acid module (included for baseline data), were evaluated under a simple HEV screening test. Both Furakawa and East Penn UltraBattery packs operated for over 32,000 HEV cycles, with minimal loss in performance; whereas the

  9. Factors Affecting the Clinical Measurement of Visuo-Spatial Neglect

    Directory of Open Access Journals (Sweden)

    L. Pizzamiglio

    1992-01-01

    Full Text Available The present study examined a battery of tests to evaluate unilateral spatial neglect; the tests included different tasks involving several modalities of spatial exploration mapping perceptual, motor, attentional and personal or extrapersonal space dimensions. The subjects, 121 right-brain-damaged patients with unilateral neglect, were studied in seven laboratories in four European countries. Relationships among the various tests were examined by correlations, a cluster analysis and by an analysis of individual cases. Different sensitivity was found among various tests for detecting neglect performances. Both the cluster analysis and the single case analysis clearly showed a segregation between personal and extrapersonal neglect. Analysis of the large cluster, including a variety of tests of extra personal neglect, together with the study of single cases, suggests the possibility of differentiating the various manifestations of spatial neglect which can be interpreted on the basis of the descriptions of other individual cases previously reported in the literature. Finally, the present study indicated the relative stability of neglect following the acute phase and its independence from age.

  10. Fast Charging and Smart Charging Tests for Electric Vehicles Batteries Using Renewable Energy

    DEFF Research Database (Denmark)

    Forero Camacho, Oscar Mauricio; Mihet-Popa, Lucian

    2016-01-01

    , and forced and pulsed power. The aim of the tests has been to study the impact of smart charging and fast charging on the power system, on the battery state of health and degradation, and to find out the limitations of the batteries for a Smart Grid. The paper outlines the advantages and disadvantages...... the development of a test platform, including three Li-ion batteries designed for EV applications, and three associated bi-directional power converters, for testing impacts on different advanced loadings of EV batteries. Different charging algorithms/profiles have been tested, including constant current and power...... of both tests in terms of regulation of the aggregated local power, power capacity and the power exchange with the grid. The smart charging tests performed have demonstrated that even with a simple control algorithm, without any forecasting, it is possible to provide the required charging and at the same...

  11. Continuous Improvement in Battery Testing at the NASA/JSC Energy System Test Area

    Science.gov (United States)

    Boyd, William; Cook, Joseph

    2003-01-01

    The Energy Systems Test Area (ESTA) at the Lyndon B. Johnson Space Center in Houston, Texas conducts development and qualification tests to fulfill Energy System Division responsibilities relevant to ASA programs and projects. EST A has historically called upon a variety of fluid, mechanical, electrical, environmental, and data system capabilities spread amongst five full-service facilities to test human and human supported spacecraft in the areas of propulsion systems, fluid systems, pyrotechnics, power generation, and power distribution and control systems. Improvements at ESTA are being made in full earnest of offering NASA project offices an option to choose a thorough test regime that is balanced with cost and schedule constraints. In order to continue testing of enabling power-related technologies utilized by the Energy System Division, an especially proactive effort has been made to increase the cost effectiveness and schedule responsiveness for battery testing. This paper describes the continuous improvement in battery testing at the Energy Systems Test Area being made through consolidation, streamlining, and standardization.

  12. A cost effective battery bank for I2t testing and evaluation of electrical switchgear

    International Nuclear Information System (INIS)

    Reass, W.A.

    1989-01-01

    This paper describes the electrical design and mechanical construction of a 50 kA ''step switched'' battery bank. Individual fuses protect each of the forty parallel isolated strings of three series (12 V) batteries. Step current waveforms of 12.5 kA, 25 kA, 37.5 kA, and 50 kA are produced by 8 sets of pneumatically driven 20 pole step switches and current limiting stainless steel ''trombone'' resistors. Inexpensive, yet conservatively designed, Group 65 Motorcraft car batteries are used to give an I 2 t capability of better than 5 x 10 9 . The battery bank has well over 1500 shots, with testing of commercial switchgear continuing. In addition to the battery bank engineering data, results of repetitive testing of vacuum interrupters at their I 2 t limit will be provided. 8 figs

  13. Development of Software and Strategies for Battery Management System Testing on HIL Simulator

    DEFF Research Database (Denmark)

    Fleischer, Christian; Sauer, Dirk Uwe; Barreras, Jorge Varela

    2016-01-01

    . This is particularly the case of tests at early stages in the development process or during fault simulation. However, the use of a HIL battery simulator requires the development of software (SW) and strategies for testing. While the possibilities are immense, it should be noted that the greater the level......In comparison with tests conducted on real Li-ion batteries, Battery Management System (BMS) tests conducted on a Hardware-In-the-Loop (HIL) battery simulator may be more cost and time effective, more flexible and traceable, easier to reproduce and safer beyond the normal range of operation...... of complexity of the tests, the higher the demands for ad hoc development of SW and strategies. With regard to the latter, there is not a universal definition and there are different points of view. Therefore different strategies may be followed, which can be classified into many different ways according...

  14. High shock load testing of lithium-thionyl chloride batteries

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, J.; Marincic, N.

    1983-10-01

    Low rate cylindrical cells have been developed, capable of withstanding mechanical shocks up to 23,000 g's for one millisecond. The cells were based on the lithium-thionyl chloride battery system and totally hermetic stainless steel hardware incorporating a glass sealed positive terminal. Four cells in series were required to deliver 25 mA pulses at a minimum voltage of 10 V before and after such exposure to one mechanical shock. Batteries were contained in a hardened steel housing and mounted within a projectile accelerated by means of a gas gun. The velocity of the projectile was measured with electronic probes immediately before impact and the deceleration was effected using a special aluminum honeycomb structure from which the g values were calculated. A high survival rate for the cells was achieved in spite of some mechanical damage to the battery housing still present.

  15. 3-D CFD modeling and experimental testing of thermal behavior of a Li-Ion battery

    International Nuclear Information System (INIS)

    Gümüşsu, Emre; Ekici, Özgür; Köksal, Murat

    2017-01-01

    Highlights: • A thermally fully predictive 3-D CFD model is developed for Li-Ion batteries. • Complete flow field around the battery and conduction inside the battery are solved. • Macro-scale thermophysical properties and the entropic term are investigated. • Discharge rate and usage history of the battery are systematically investigated. • Reliability of the model was tested through experimental measurements. - Abstract: In this study, a 3-D computational fluid dynamics model was developed for investigating the thermal behavior of lithium ion batteries under natural convection. The model solves the complete flow field around the battery as well as conduction inside the battery using the well-known heat generation model of Bernardi et al. (1985). The model is thermally fully predictive so it requires only electrical performance parameters of the battery to calculate its temperature during discharging. Using the model, detailed investigation of the effects of the variation of the macro-scale thermophysical properties and the entropic term of the heat generation model was carried out. Results show that specific heat is a critical property that has a significant impact on the simulation results whereas thermal conductivity has relatively minor importance. Moreover, the experimental data can be successfully predicted without taking the entropic term into account in the calculation of the heat generation. The difference between the experimental and predicted battery surface temperature was less than 3 °C for all discharge rates and regardless of the usage history of the battery. The developed model has the potential to be used for the investigation of the thermal behavior of Li-Ion batteries in different packaging configurations under natural and forced convection.

  16. Installing a Test Tap on a Metal Battery Case

    Science.gov (United States)

    Mayes, Daniel R.; Rybicki, Daniel J.

    2009-01-01

    A mechanical fitting and relatively simple and safe method of installing it on the metal case of a battery have been devised to provide access to the interior of the battery to perform inspection and/or to measure such internal conditions as temperature and pressure. A metal boss or stud having an exterior thread is attached to the case by capacitor-discharge stud welding (CDSW), which takes only 3 to 6 milliseconds and in which the metallurgical bond (weld) and the heat-affected zone are limited to a depth of a few thousandths of an inch (a few hundredths of a millimeter). These characteristics of CDSW prevent distortion of the case and localized internal heating that could damage the chemical components inside of the battery. An access hole is then drilled through the stud and case, into the interior of the battery. A mechanical fitting having a matching thread is installed on the stud and the interior end of the fitting is sealed with a pressure-sealing washer/gasket. The exterior end of the fitting is configured for attachment of whatever instrumentation is required for the selected inspection or measurement.

  17. Systematic review and proposal of a field-based physical fitness-test battery in preschool children: the PREFIT battery.

    Science.gov (United States)

    Ortega, Francisco B; Cadenas-Sánchez, Cristina; Sánchez-Delgado, Guillermo; Mora-González, José; Martínez-Téllez, Borja; Artero, Enrique G; Castro-Piñero, Jose; Labayen, Idoia; Chillón, Palma; Löf, Marie; Ruiz, Jonatan R

    2015-04-01

    Physical fitness is a powerful health marker in childhood and adolescence, and it is reasonable to think that it might be just as important in younger children, i.e. preschoolers. At the moment, researchers, clinicians and sport practitioners do not have enough information about which fitness tests are more reliable, valid and informative from the health point of view to be implemented in preschool children. Our aim was to systematically review the studies conducted in preschool children using field-based fitness tests, and examine their (1) reliability, (2) validity, and (3) relationship with health outcomes. Our ultimate goal was to propose a field-based physical fitness-test battery to be used in preschool children. PubMed and Web of Science. Studies conducted in healthy preschool children that included field-based fitness tests. When using PubMed, we included Medical Subject Heading (MeSH) terms to enhance the power of the search. A set of fitness-related terms were combined with 'child, preschool' [MeSH]. The same strategy and terms were used for Web of Science (except for the MeSH option). Since no previous reviews with a similar aim were identified, we searched for all articles published up to 1 April 2014 (no starting date). A total of 2,109 articles were identified, of which 22 articles were finally selected for this review. Most studies focused on reliability of the fitness tests (n = 21, 96%), while very few focused on validity (0 criterion-related validity and 4 (18%) convergent validity) or relationship with health outcomes (0 longitudinal and 1 (5%) cross-sectional study). Motor fitness, particularly balance, was the most studied fitness component, while cardiorespiratory fitness was the least studied. After analyzing the information retrieved in the current systematic review about fitness testing in preschool children, we propose the PREFIT battery, field-based FITness testing in PREschool children. The PREFIT battery is composed of the following

  18. Psychometric evaluation of a motor control test battery of the craniofacial region.

    Science.gov (United States)

    von Piekartz, H; Stotz, E; Both, A; Bahn, G; Armijo-Olivo, S; Ballenberger, N

    2017-12-01

    The primary objective of this study was to determine the structural and known-group validity as well as the inter-rater reliability of a test battery to evaluate the motor control of the craniofacial region. Seventy volunteers without TMD and 25 subjects with TMD (Axes I) per the DC/TMD were asked to execute a test battery consisting of eight tests. The tests were video-taped in the same sequence in a standardised manner. Two experienced physical therapists participated in this study as blinded assessors. We used exploratory factor analysis to identify the underlying component structure of the eight tests. Internal consistency (Cronbach's α), inter-rater reliability (intra-class correlation coefficient) and construct validity (ie, hypothesis testing-known-group validity) (receiver operating curves) were also explored for the test battery. The structural validity showed the presence of one factor underlying the construct of the test battery. The internal consistency was excellent (0.90) as well as the inter-rater reliability. All values of reliability were close to 0.9 or above indicating very high inter-rater reliability. The area under the curve (AUC) was 0.93 for rater 1 and 0.94 for rater two, respectively, indicating excellent discrimination between subjects with TMD and healthy controls. The results of the present study support the psychometric properties of test battery to measure motor control of the craniofacial region when evaluated through videotaping. This test battery could be used to differentiate between healthy subjects and subjects with musculoskeletal impairments in the cervical and oro-facial regions. In addition, this test battery could be used to assess the effectiveness of management strategies in the craniofacial region. © 2017 John Wiley & Sons Ltd.

  19. Evaluation of a new charge algorithm for a lead-acid battery with gelled electrolyte using a 96V gel cell 4 as a test battery

    Science.gov (United States)

    Nowak, Dieter K.

    1989-10-01

    A summary is reported of test results obtained utilizing the new UAH charge algorithm for Lead-Acid batteries with gelled electrolyte. The battery performance data for a 96V Phase 4 Gel/Cell battery pack was tested in a Jet Industries Electrica vehicle. It was shown that the new charge concept is sound although there can be problems with batteries that are highly imbalanced and where excessive electronic noise is experienced on the electronic signal feed-back line that carries the voltage sensor signals from the battery. Additional work is needed to add intelligence to the charge algorithm in terms of a better ability to extract the beginning of gas development from the voltage spread function. This can probably be accomplished by scanning the voltages more often and including that data into the function analysis by adding software filters. The Phase 4 Gel/Cell battery performance was found to be about 20 percent lower than that of the Phase 3 Gel/Cell battery. Problems with cell valve leakage were encountered in the Phase 4 Gel/Cell that pose a threat to battery life although so far no battery module has been lost.

  20. Early Education Screening Test Battery of Basic Skills Development: Criteria for Personalizing Programs.

    Science.gov (United States)

    University City School District, MO.

    The development and content of the Early Education Screening Test Battery are described elsewhere (TM 000 184). This report provides norms for the Gross Motor Test (GMO), Visual-Motor Integration (VMI), four scales of the Illinois Test of Psycholinguistic Abilities (ITPA), Peabody Picture Vocabulary Test (PPVT), and the Behavior Rating Scale…

  1. Running Test of VVVF Inverter Type Railcar Using Lithium Ion Battery

    OpenAIRE

    OGIHARA, Takashi; YAMANAKA, Shigenobu

    2009-01-01

    Lithium ion battery was applied to the running of VVVF inverter type railcar. 15kWh of Mn type lithium ion battery was used. The relation between running time and voltage, current and integrating watt was investigated. The running test was also carried out using VVVF inverter type railcar to investigate charge performance due to regenerative energy. Lithium ion battery module was quickly charged for three times at rate of 4.68C by regenerative braking system. It was estimated that the effect ...

  2. Performance Tests for Repeated Measures: Moran and Computer Batteries.

    Science.gov (United States)

    1981-11-01

    Incomplete Words. The SC score was number of words correctly circled in 150 seconds. Vizualization (V). This task required the visual follow- ing of the...the Ekstrom, et al. SS Factor which was defined as "Speed in exploring visually a wide or complicated spatial field". Scoring on the Vizualization (V...Computer Batteries 4 tion 3900.6 Series. These instructions are based on voluntary informed consent and meet provisions of prevailing national and

  3. A computerized neuropsychological test battery designed for idiopathic normal pressure hydrocephalus

    Science.gov (United States)

    2014-01-01

    Background A tool for standardized and repeated neuropsychological assessments in patients with idiopathic normal pressure hydrocephalus (INPH) is needed. The objective of this study was to develop a computerized neuropsychological test battery designed for INPH and to evaluate its reliability, validity and patient’s ability to complete the tests. Methods Based on a structured review of the literature on neuropsychological testing in INPH, the eight tests most sensitive to the INPH cognitive profile were implemented in a computerized format. The Geriatric Depression Scale (GDS) was also included. Tests were presented on a touch-screen monitor, with animated instructions and speaker sound. The battery was evaluated with the following cohorts: A. Test-retest reliability, 44 healthy elderly; B. Validity against standard pen and pencil testing, 28 patients with various cognitive impairments; C. Ability to complete test battery, defined as completion of at least seven of the eight tests, 40 investigated for INPH. Results A. All except the figure copy test showed good test-retest reliability, r = 0.67-0.90; B. A high correlation was seen between conventional and computerized tests (r = 0.66-0.85) except for delayed recognition and figure copy task; C. Seventy-eight percent completed the computerized battery; Patients diagnosed with INPH (n = 26) performed worse on all tests, including depression score, compared to healthy controls. Conclusions A new computerized neuropsychological test battery designed for patients with communicating hydrocephalus and INPH was introduced. Its reliability, validity for general cognitive impairment and completion rate for INPH was promising. After exclusion of the figure copy task, the battery is ready for clinical evaluation and as a next step we suggest validation for INPH and a comparison before and after shunt surgery. Trial registration ClinicalTrials.org NCT01265251. PMID:25279138

  4. Functional Assessment of Battery Management System Tested on Hardware-in-the-Loop Simulator

    DEFF Research Database (Denmark)

    Kalogiannis, Theodoros; Stroe, Daniel-Ioan; Swierczynski, Maciej Jozef

    2017-01-01

    A Hardware-in-the-Loop (HIL) simulator renders possible to conduct on-line tests on Battery Management Systems (BMSs) with an emulated battery pack instead of a real one. In this case, the BMS can be repeatedly evaluated under the exact same experimental scenarios, with safety and accuracy......, or under a flexible and beyond the normal operation area range, with less cost and time efforts. For this purpose, a multi-cell Li-ion battery pack consisting of 32 cells in series has been implemented and validated based on experimental results, converted into C code and emulated through the HIL simulator....... The BMS under test is interacting in real-time with the emulated battery pack and several of its functions such as current, voltage and State of Charge (SOC) estimation are evaluated. Also, passive balancing experiments are conducted during charging in order to assess different balancing settings...

  5. 78 FR 15753 - Maintenance, Testing, and Replacement of Vented Lead-Acid Storage Batteries for Nuclear Power Plants

    Science.gov (United States)

    2013-03-12

    ...-Acid Storage Batteries for Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION: Draft...-Acid Storage Batteries for Nuclear Power Plants.'' The draft guide describes methods that the NRC staff..., testing, and replacement of vented lead-acid storage batteries in nuclear power plants. DATES: Submit...

  6. Performance Model for High-Power Lithium Titanate Oxide Batteries based on Extended Characterization Tests

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Swierczynski, Maciej Jozef; Stroe, Daniel Ioan

    2015-01-01

    Lithium-ion (Li-ion) batteries are found nowadays not only in portable/consumer electronics but also in more power demanding applications, such as stationary renewable energy storage, automotive and back-up power supply, because of their superior characteristics in comparison to other energy stor...... model for a commercially available 13Ah high-power lithium titanate oxide battery cell based on laboratory-performed extended characterization tests....

  7. Spatial neglect

    Science.gov (United States)

    Li, Korina; Malhotra, Paresh A

    2015-01-01

    The syndrome of visuospatial neglect is a common consequence of unilateral brain injury. It is most often associated with stroke and is more severe and persistent following right hemisphere damage, with reported frequencies in the acute stage of up to 80%. Neglect is primarily a disorder of attention whereby patients characteristically fail to orientate, to report or to respond to stimuli located on the contralesional side. Neglect is usually caused by large strokes in the middle cerebral artery territory and is heterogeneous, such that most patients do not manifest every feature of the syndrome. A number of treatments may improve neglect, but there is no widely accepted universal approach to therapy. Although most patients recover spontaneously, the evidence suggests that they continue to have significant cognitive impairments, particularly relating to attention. PMID:26023203

  8. Log Scaler (logging; paper & pulp; sawmill) 941.488--Technical Report on USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  9. Toxicity assessment of sediments from three European river basins using a sediment contact test battery

    NARCIS (Netherlands)

    Tuikka, A.I.; Schmitt, C.; Hoess, S.; Bandow, N; von der Ohe, P.; de Zwart, D.; de Deckere, E.; Streck, G.; Mothes, S.; van Hattum, A.G.M.; Kocan, A.; Brix, R.; Brack, W.; Barcelo, D.; Sormunen, A.; Kukkonen, J.V.K.

    2011-01-01

    The toxicity of four polluted sediments and their corresponding reference sediments from three European river basins were investigated using a battery of six sediment contact tests representing three different trophic levels. The tests included were chronic tests with the oligochaete Lumbriculus

  10. The decision of out-of-home placement in residential care after parental neglect: Empirically testing a psychosocial model.

    Science.gov (United States)

    Rodrigues, Leonor; Calheiros, Manuela; Pereira, Cícero

    2015-11-01

    Out-of-home placement decisions in residential care are complex, ambiguous and full of uncertainty, especially in cases of parental neglect. Literature on this topic is so far unable to understand and demonstrate the source of errors involved in those decisions and still fails to focus on professional's decision making process. Therefore, this work intends to test a socio-psychological model of decision-making that is a more integrated, dualistic and ecological version of the Theory of Planned Behavior's model. It describes the process through which the decision maker takes into account personal, contextual and social factors of the Decision-Making Ecology in the definition of his/her decision threshold. One hundred and ninety-five professionals from different Children and Youth Protection Units, throughout the Portuguese territory, participated in this online study. After reading a vignette of a (psychological and physical) neglect case toward a one-year-old child, participants were presented with a group of questions that measured worker's assessment of risk, intention, attitude, subjective norm, behavior control and beliefs toward residential care placement decision, as well as worker's behavior experience, emotions and family/child-related-values involved in that decision. A set of structural equation modeling analyses have proven the good fit of the proposed model. The intention to propose a residential care placement decision was determined by cognitive, social, affective, value-laden and experience variables and the perceived risk. Altogether our model explained 61% of professional's decision toward a parental neglect case. The theoretical and practical implications of these results are discussed, namely the importance of raising awareness about the existence of these biased psychosocial determinants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. 24-hour assessment of performance on a palmtop computer: validating a self-constructed test battery.

    Science.gov (United States)

    Varkevisser, Michael; Kerkhof, Gerard A

    2003-01-01

    A test battery was constructed on a palmtop computer for ambulatory purposes. This study explored whether the test battery could assess circadian rhythmicity underconstant routine conditions. Performance, body temperature, and subjective sleepiness of 12 healthy subjects were measured. The test battery consisted of a sleepiness questionnaire and three performance tests: a vigilance detection test, a working memory test, and a choice-reaction time test. The subjects were divided into early-start and late-start groups and were subjected to the constant-routine protocol. All tests showed a trough in performance in the early morning around 07:00h and a peak in the evening between 21:00 and 23:00h. In addition, an afternoon decrement in performance was observed between 15:00 and 17:00h. On average, the circadian (peak-to-trough) variation of the performance variables amounted to 16.9% +/- 1.7 SEM of the maximum across subjects. The late starters showed a larger impairment in performance during the morning than the early starters. This could be attributed to prior wakefulness. The characteristics of the performance rhythms found in this study replicate findings in several other studies carried out under constant routine conditions. In conclusion, the present test battery appeared to be a good tool for future assessment of performance under natural conditions.

  12. Electrical Vehicle Batteries Testing in a Distribution Network Using Sustainable Energy

    DEFF Research Database (Denmark)

    Forero Camacho, Oscar Mauricio; Nørgård, Per Bromand; Rao, Ningling

    2014-01-01

    , there is an outstanding need for common platforms and sharing of knowledge and core technologies. This paper presents the development of a test platform, including three Li-ion batteries designed for EV applications and three associated bi-directional power converters, for testing impacts on different advanced loadings...

  13. Combining decision trees and stochastic curtailment for assessment length reduction of test batteries used for classification.

    NARCIS (Netherlands)

    Fokkema, M.; Smits, N.; Kelderman, H.; Carlier, I.V.E.; van Hemert, A.M.

    2014-01-01

    For classification problems in psychology (e.g., clinical diagnosis), batteries of tests are often administered. However, not every test or item may be necessary for accurate classification. In the current article, a combination of classification and regression trees (CART) and stochastic

  14. Study of the fire behavior of high-energy lithium-ion batteries with full-scale burning test

    Science.gov (United States)

    Ping, Ping; Wang, QingSong; Huang, PeiFeng; Li, Ke; Sun, JinHua; Kong, DePeng; Chen, ChunHua

    2015-07-01

    A full-scale burning test is conducted to evaluate the safety of large-size and high-energy 50 Ah lithium-iron phosphate/graphite battery pack, which is composed of five 10 Ah single cells. The complex fire hazards associated with the combustion process of the battery are presented. The battery combustion behavior can be summarized into the following stages: battery expansion, jet flame, stable combustion, a second cycle of a jet flame followed by stable combustion, a third cycle of a jet flame followed by stable combustion, abatement and extinguishment. The multiple jets of flame indicate serious consequences for the battery and pose a challenge for battery safety. The battery ignites when the battery temperature reaches approximately 175-180 °C. This critical temperature is related to an internal short circuit of the battery, which results from the melting of the separator. The maximum temperature of the flame can reach 1500 °C. The heat release rate (HRR) varies based on the oxygen generated by the battery and the Joule effect of the internal short circuit. The HRR and heat of combustion can reach 49.4 kW and 18,195.1 kJ, respectively. The state of charge of the battery has a significant effect on the maximum HRR, the overall heat generation and the mass loss of the battery.

  15. The testing of batteries linked to supercapacitors with electrochemical impedance spectroscopy: A comparison between Li-ion and valve regulated lead acid batteries

    Science.gov (United States)

    Ferg, Ernst; Rossouw, Claire; Loyson, Peter

    2013-03-01

    For electric vehicles, a supercapacitor can be coupled to the electrical system in order to increase and optimize the energy and power densities of the drive system during acceleration and regenerative breaking. This study looked at the charge acceptance and maximum discharge ability of a valve regulated lead acid (VRLA) and a Li-ion battery connected in parallel to supercapacitors. The test procedure evaluated the advantage of using a supercapacitor at a 2 F:1 Ah ratio with the battery types at various states of charge (SoC). The results showed that about 7% of extra charge was achieved over a 5-s test time for a Li-ion hybrid system at 20% SoC, whereas at the 80% SoC the additional capacity was approximately 16%. While for the VRLA battery hybrid system, an additional charge of up to 20% was achieved when the battery was at 80% SoC, with little or no benefit at the 20% SoC. The advantage of the supercapacitor in parallel with a VRLA battery was noticeable on its discharge ability, where significant extra capacity was achieved for short periods of time for a battery at the 60% and 40% SoC when compared to the Li-ion hybrid system. The study also made use of Electrochemical Impedance Spectroscopy (EIS) with a suitable equivalent circuit model to explain, in particular, the internal resistance and capacitance differences observed between the different battery chemistries with and without a supercapacitor.

  16. The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.

    Science.gov (United States)

    Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar

    2018-03-01

    This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility ( 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near

  17. Mars Mission Surface Operation Simulation Testing of Lithium-Ion Batteries

    Science.gov (United States)

    Smart, M. C.; Bugga, R.; Whitcanack, L. D.; Chin, K. B.; Davies, E. D.; Surampudi, S.

    2003-01-01

    The objectives of this program are to 1) Assess viability of using lithium-ion technology for future NASA applications, with emphasis upon Mars landers and rovers which will operate on the planetary surface; 2) Support the JPL 2003 Mars Exploration Rover program to assist in the delivery and testing of a 8 AHr Lithium-Ion battery (Lithion/Yardney) which will power the rover; 3) Demonstrate applicability of using lithium-ion technologyfor future Mars applications: Mars 09 Science Laboratory (Smart Lander) and Future Mars Surface Operations (General). Mission simulation testing was carried out for cells and batteries on the Mars Surveyor 2001 Lander and the 2003 Mars Exploration Rover.

  18. Software control program for 25 kW breadboard testing. [spacecraft power supplies; high voltage batteries

    Science.gov (United States)

    Pajak, J. A.

    1981-01-01

    A data acquisition software program developed to operate in conjunction with the automated control system of the 25 kW PM Electric Power System Breadboard Test facility is described. The proram provides limited interactive control of the breadboard test while acquiring data and monitoring parameters, allowing unattended continuous operation. The breadboard test facility has two positions for operating separate configurations. The main variable in each test setup is the high voltage Ni-Cd battery.

  19. Fast Charging and Smart Charging Tests for Electric Vehicles Batteries Using Renewable Energy

    Directory of Open Access Journals (Sweden)

    Forero Camacho Oscar Mauricio

    2016-01-01

    Full Text Available Electric Vehicles (EV technologies are still relatively new and under strong development. Although some standardized solutions are being promoted and becoming a new trend, there is an outstanding need for common platforms and sharing of knowledge and core technologies. This paper presents the development of a test platform, including three Li-ion batteries designed for EV applications, and three associated bi-directional power converters, for testing impacts on different advanced loadings of EV batteries. Different charging algorithms/profiles have been tested, including constant current and power, and forced and pulsed power. The aim of the tests has been to study the impact of smart charging and fast charging on the power system, on the battery state of health and degradation, and to find out the limitations of the batteries for a Smart Grid. The paper outlines the advantages and disadvantages of both tests in terms of regulation of the aggregated local power, power capacity and the power exchange with the grid. The smart charging tests performed have demonstrated that even with a simple control algorithm, without any forecasting, it is possible to provide the required charging and at the same time the power system services, reducing the peak power and the energy losses in the power connection line of the power exchange with the national grid.

  20. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    Science.gov (United States)

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  1. Using clinical signs of neglect to identify elder neglect cases.

    Science.gov (United States)

    Friedman, Lee S; Avila, Susan; Liu, Elaine; Dixon, Kimberly; Patch, Olivia; Partida, Renee; Zielke, Holly; Giloth, Barbara; Friedman, Daniel; Moorman, Lois; Meltzer, Wendy

    2017-01-01

    Elder neglect is the one of the most pervasive forms of mistreatment, and often the only place outside of the individual's residence to identify and assist neglected individuals is in a medical setting. However, elder neglect cases treated in hospitals do not present with a single diagnosis or clinical sign, but rather involve a complex constellation of clinical signs. Currently, there is a lack of comprehensive guidelines on which clinical signs to use in screening tools for neglect among patients treated in hospitals. Using the DELPHI method, a group of experts developed and tested a scale to be used as a pre-screener that conceptually could be integrated into electronic health record systems so that it could identify potential neglect cases in an automated manner. By applying the scale as a pre-screener for neglect, the tool would reduce the pool of at-risk patients who would benefit from in-depth screening for elder neglect by 95%.

  2. Development of a standardized battery of performance tests for the assessment of noise stress effects

    Science.gov (United States)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  3. Evaluation of the preliminary auditory profile test battery in an international multi-centre study

    NARCIS (Netherlands)

    van Esch, T.E.M.; Kollmeier, B.; Vormann, M.; Lijzenga, J.; Houtgast, T.; Hallgren, M.; Larsby, B.; Athalye, S.P.; Lutman, M.E.; Dreschler, W.A.

    2013-01-01

    Objective: This paper describes the composition and international multi-centre evaluation of a battery of tests termed the preliminary auditory profile. It includes measures of loudness perception, listening effort, speech perception, spectral and temporal resolution, spatial hearing, self-reported

  4. Evaluation of the preliminary auditory profile test battery in an international multi-centre study

    NARCIS (Netherlands)

    van Esch, Thamar E. M.; Kollmeier, Birger; Vormann, Matthias; Lyzenga, Johannes; Houtgast, Tammo; Hällgren, Mathias; Larsby, Birgitta; Athalye, Sheetal P.; Lutman, Mark E.; Dreschler, Wouter A.

    2013-01-01

    This paper describes the composition and international multi-centre evaluation of a battery of tests termed the preliminary auditory profile. It includes measures of loudness perception, listening effort, speech perception, spectral and temporal resolution, spatial hearing, self-reported disability

  5. Issues in Development of the Test Battery for Australian Sign Language Morphology and Syntax.

    Science.gov (United States)

    Schembri, Adam; Wigglesworth, Gillian; Johnston, Trevor; Leigh, Greg; Adam, Robert; Barker, Roz

    2002-01-01

    This article describes the adaptation of the Test Battery for American Sign Language Morphology and Syntax for Australian Sign Language. Data collected from a group of native signers who were deaf (n=25) demonstrate the range of variability in key grammatical features of Australian Sign Language and raise methodological issues. (Contains…

  6. Development and testing of a bipolar lead-acid battery for hybrid electric vehicles

    NARCIS (Netherlands)

    Saakes, M.; Kluiters, E.; Schmal, D.; Mourad, S.; Have, P.T.J.H. ten

    1999-01-01

    An 80 V bipolar lead-acid battery was constructed and tested using hybrid electric vehicle (HEV) drive cycles. Drive cycles with a peak power of 6.7 kW, equal to 1/5 of the total power profile required for the HEV studied, were run successfully. Model calculations showed that the 80 V module

  7. Identification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte; Seeto, Mark; Freeston, Katrina; Zhou, Dan; Dillon, Harvey

    2014-01-01

    The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary according to hearing loss type. A secondary objective was to evaluate the reliability and validity of a novel automatic audiometry algorithm to assess its suitability for inclusion in the test battery. Participants underwent a series of hearing assessments that were conducted in a randomized order: manual pure-tone air conduction audiometry and bone conduction audiometry; automatic pure-tone air conduction audiometry; and an automatic tone-in-noise detection task. The automatic tests were each administered twice. The ability of the automatic test battery to: (a) predict the presence of an air-bone gap (ABG); and (b) accurately measure AC hearing thresholds was assessed against the results of manual audiometry. Test-retest conditions were compared to determine the reliability of each component of the automatic test battery. Data were collected on 120 ears from normal-hearing and conductive, sensorineural, and mixed hearing-loss subgroups. Performance differences between different types of hearing loss were observed. Ears with a conductive component (conductive and mixed ears) tended to have normal signal to noise ratios (SNR) despite impaired thresholds in quiet, while ears without a conductive component (normal and sensorineural ears) demonstrated, on average, an increasing relationship between their thresholds in quiet and their achieved SNR. Using the relationship between these two measures among ears with no conductive component as a benchmark, the likelihood that an ear has a conductive component can be estimated based on the deviation from this benchmark. The sensitivity and

  8. Batteries for Electric Vehicles

    Science.gov (United States)

    Conover, R. A.

    1985-01-01

    Report summarizes results of test on "near-term" electrochemical batteries - (batteries approaching commercial production). Nickel/iron, nickel/zinc, and advanced lead/acid batteries included in tests and compared with conventional lead/acid batteries. Batteries operated in electric vehicles at constant speed and repetitive schedule of accerlerating, coasting, and braking.

  9. Accelerated lifetime testing methodology for lifetime estimation of Lithium-ion batteries used in augmented wind power plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina

    2013-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium-ion batteries. The results obtained at the end of the accelerated ageing process can be used for the parametrization of a performance-degradation lifetime model. In the proposed...... methodology both calendar and cycling lifetime tests are considered since both components are influencing the lifetime of Lithium-ion batteries. The methodology proposes also a lifetime model verification stage, where Lithium-ion battery cells are tested at normal operating conditions using an application...

  10. The Construction of a Muscular Strength Test Battery for Girls in the Primary Grades.

    Science.gov (United States)

    DiNucci, James M.; Pelton, Elois B.

    This study was designed to construct a gross muscular strength test battery for girls 6-9 years of age in grades 1-3. The subjects for this investigation were a random sample of 183 girls in grades 1-3 of the public schools of Natchitoches, Louisiana. The variables selected were 22 cable tension strength tests developed by Clarke and associates.…

  11. Test series 1: seismic-fragility tests of naturally-aged Class 1E Gould NCX-2250 battery cells

    Energy Technology Data Exchange (ETDEWEB)

    Bonzon, L. L.; Hente, D. B.; Kukreti, B. M.; Schendel, J. S.; Tulk, J. D.; Janis, W. J.; Black, D A; Paulsen, G. D.; Aucoin, B. D.

    1984-09-01

    The seismic-fragility response of naturally-aged, nuclear station, safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and thresholds; and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the end-of-life of a battery, given a seismic event. This report covers the first test series of an extensive program using 12-year old, lead-calcium, Gould NCX-2250 cells, from the James A. Fitzpatrick Nuclear Power Station operated by the New York Power Authority. Seismic tests with three cell configurations were performed using a triaxial shake table: single-cell tests, rigidly mounted; multi-cell (three) tests, mounted in a typical battery rack; and single-cell tests specifically aimed towards examining propagation of pre-existing case cracks. In general the test philosophy was to monitor the electrical properties including discharge capacity of cells through a graduated series of g-level step increases until either the shake-table limits were reached or until electrical failure of the cells occurred. Of nine electrically active cells, six failed during seismic testing over a range of imposed g-level loads in excess of a 1-g ZPA. Post-test examination revealed a common failure mode, the cracking at the abnormally brittle, positive lead bus-bar/post interface; further examination showed that the failure zone was extremely coarse grained and extensively corroded. Presently accepted accelerated-aging methods for qualifying batteries, per IEEE Std. 535-1979, are based on plate growth, but these naturally-aged 12-year old cells showed no significant plate growth.

  12. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  13. The Cambridge Mindreading (CAM) Face-Voice Battery: Testing Complex Emotion Recognition in Adults with and without Asperger Syndrome

    Science.gov (United States)

    Golan, Ofer; Baron-Cohen, Simon; Hill, Jacqueline

    2006-01-01

    Adults with Asperger Syndrome (AS) can recognise simple emotions and pass basic theory of mind tasks, but have difficulties recognising more complex emotions and mental states. This study describes a new battery of tasks, testing recognition of 20 complex emotions and mental states from faces and voices. The battery was given to males and females…

  14. Reperfusion of specific cortical areas is associated with improvement in distinct forms of hemispatial neglect.

    Science.gov (United States)

    Khurshid, Shaan; Trupe, Lydia A; Newhart, Melissa; Davis, Cameron; Molitoris, John J; Medina, Jared; Leigh, Richard; Hillis, Argye E

    2012-05-01

    To test the hypothesis that restoring blood flow to specific right cortical regions in acute stroke results in improvement in distinct forms of hemispatial neglect distinguished by reference frame: viewer-centered versus stimulus-centered neglect. Twenty five patients with acute right stroke were evaluated at Day 1 and Day 3-5 with a battery of neglect tests and Diffusion- and Perfusion-Weighted MR Imaging. Multivariate linear regression analysis revealed Brodmann areas (BAs) where reperfusion predicted degree of improvement in scores on each type of neglect, independently of reperfusion of other areas, total change in the volume of infarct or hypoperfusion, and age. Reperfusion of dorsal frontoparietal cortex (including BAs 40, 46, and 4) independently predicted improvement in viewer-centered neglect, such as detecting stimuli on left in line cancellation and scene copying (r=.951; p<.0001). Reperfusion of a more ventral temporo-occipital cortex, including right BAs 37, 38, 21 and 18, independently contributed to improvement in stimulus-centered neglect, such as detecting left gaps in circles (r=.926; p<.0001). Reperfusion of right midfusiform gyrus (temporal occipital cortex), change in total volume of ischemia, change in volume of hypoperfusion and age predicted degree of improvement in reading (reduction in "neglect dyslexic" errors; r=.915; p<.0001). Results demonstrate that reperfusing specific cortical regions yields improvement in different types of neglect. Copyright © 2011 Elsevier Srl. All rights reserved.

  15. Selected test results from the neosonic polymer Li-ion battery.

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, David T.; Hund, Thomas D.

    2010-07-01

    The performance of the Neosonic polymer Li-ion battery was measured using a number of tests including capacity, capacity as a function of temperature, ohmic resistance, spectral impedance, hybrid pulsed power test, utility partial state of charge (PSOC) pulsed cycle test, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the polymer Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, wind farm energy smoothing, and solar photovoltaic energy smoothing. Test results have indicated that the Neosonic polymer Li-ion battery technology can provide power levels up to the 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h (1C) discharge rate. Two of the three cells used in the utility PSOC pulsed cycle test completed about 12,000 cycles with only a gradual loss in capacity of 10 and 13%. The third cell experienced a 40% loss in capacity at about 11,000 cycles. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were increases in impedance after cycling, especially for the third cell. Cell No.3 impedance Rs increased significantly along with extensive ballooning of the foil pouch. Finally, at a 1C (10 A) charge rate, the over charge/voltage abuse test with cell confinement similar to a multi cell string resulted in the cell venting hot gases at about 45 C 45 minutes into the test. At 104 minutes into the test the cell voltage spiked to the 12 volt limit and continued out to the end of the test at 151 minutes. In summary, the Neosonic cells performed as expected with good cycle-life and safety.

  16. Evaluation of the preliminary auditory profile test battery in an international multi-centre study.

    Science.gov (United States)

    van Esch, Thamar E M; Kollmeier, Birger; Vormann, Matthias; Lyzenga, Johannes; Houtgast, Tammo; Hällgren, Mathias; Larsby, Birgitta; Athalye, Sheetal P; Lutman, Mark E; Dreschler, Wouter A

    2013-05-01

    This paper describes the composition and international multi-centre evaluation of a battery of tests termed the preliminary auditory profile. It includes measures of loudness perception, listening effort, speech perception, spectral and temporal resolution, spatial hearing, self-reported disability and handicap, and cognition. Clinical applicability and comparability across different centres are investigated. Headphone tests were conducted in five centres divided over four countries. Effects of test-retest, ear, and centre were investigated. Results for normally-hearing (NH) and hearing-impaired (HI) listeners are presented. Thirty NH listeners aged 19-39 years, and 72 HI listeners aged 22-91 years with a broad range of hearing losses were included. Test-retest reliability was generally good and there were very few right/left ear effects. Results of all tests were comparable across centres for NH listeners after baseline correction to account for necessary differences between test materials. For HI listeners, results were comparable across centres for the language-independent tests. The auditory profile forms a clinical test battery that is applicable in four different languages. Even after baseline correction, differences between test materials have to be taken into account when interpreting results of language-dependent tests in HI listeners.

  17. An alcohol withdrawal test battery measuring multiple behavioral symptoms in mice.

    Science.gov (United States)

    Metten, Pamela; Schlumbohm, Jason P; Huang, Lawrence C; Greenberg, Gian D; Hack, Wyatt R; Spence, Stephanie E; Crabbe, John C

    2017-09-06

    Despite acceptance that risk for alcohol-use disorder (AUD) has a large genetic component, the identification of genes underlying various components of risk for AUD has been hampered in humans, in part by the heterogeneity of expression of the phenotype. One aspect of AUD is physical dependence. Alcohol withdrawal is a serious consequence of alcohol dependence with multiple symptoms, many of which are seen in multiple species, and can be experienced over a wide-ranging time course. In the present three studies, we developed a battery of withdrawal tests in mice, examining behavioral symptoms from multiple domains that could be measured over time. To permit eventual use of the battery in different strains of mice, we used male and female mice of a genetically heterogeneous stock developed from intercrossing eight inbred strains. Withdrawal symptoms were assessed using commonly used tests after administration of ethanol in vapor for 72 continuous hours. We found significant effects of ethanol withdrawal versus air-breathing controls on nearly all symptoms, spanning 4 days following ethanol vapor inhalation. Withdrawal produced hypothermia, greater neurohyperexcitability (seizures and tremor), anxiety-like behaviors using an apparatus (such as reduced transitions between light and dark compartments), anhedonia (reduced sucrose preference), Straub tail, backward walking, and reductions in activity; however, there were no changes in thermal pain sensitivity, hyper-reactivity to handling, or anxiety-like emergence behaviors in other apparatus. Using these data, we constructed a refined battery of withdrawal tests. Individual differences in severity of withdrawal among different tests were weakly correlated at best. This battery should be useful for identifying genetic influences on particular withdrawal behaviors, which should reflect the influences of different constellations of genes. Published by Elsevier Inc.

  18. Validation of the Cognition Test Battery for Spaceflight in a Sample of Highly Educated Adults.

    Science.gov (United States)

    Moore, Tyler M; Basner, Mathias; Nasrini, Jad; Hermosillo, Emanuel; Kabadi, Sushila; Roalf, David R; McGuire, Sarah; Ecker, Adrian J; Ruparel, Kosha; Port, Allison M; Jackson, Chad T; Dinges, David F; Gur, Ruben C

    2017-10-01

    Neuropsychological changes that may occur due to the environmental and psychological stressors of prolonged spaceflight motivated the development of the Cognition Test Battery. The battery was designed to assess multiple domains of neurocognitive functions linked to specific brain systems. Tests included in Cognition have been validated, but not in high-performing samples comparable to astronauts, which is an essential step toward ensuring their usefulness in long-duration space missions. We administered Cognition (on laptop and iPad) and the WinSCAT, counterbalanced for order and version, in a sample of 96 subjects (50% women; ages 25-56 yr) with at least a Master's degree in science, technology, engineering, or mathematics (STEM). We assessed the associations of age, sex, and administration device with neurocognitive performance, and compared the scores on the Cognition battery with those of WinSCAT. Confirmatory factor analysis compared the structure of the iPad and laptop administration methods using Wald tests. Age was associated with longer response times (mean β = 0.12) and less accurate (mean β = -0.12) performance, women had longer response times on psychomotor (β = 0.62), emotion recognition (β = 0.30), and visuo-spatial (β = 0.48) tasks, men outperformed women on matrix reasoning (β = -0.34), and performance on an iPad was generally faster (mean β = -0.55). The WinSCAT appeared heavily loaded with tasks requiring executive control, whereas Cognition assessed a larger variety of neurocognitive domains. Overall results supported the interpretation of Cognition scores as measuring their intended constructs in high performing astronaut analog samples.Moore TM, Basner M, Nasrini J, Hermosillo E, Kabadi S, Roalf DR, McGuire S, Ecker AJ, Ruparel K, Port AM, Jackson CT, Dinges DF, Gur RC. Validation of the Cognition Test Battery for spaceflight in a sample of highly educated adults. Aerosp Med Hum Perform. 2017; 88(10):937-946.

  19. The Munich High Ability Test Battery (MHBT): A multidimensional, multimethod approach

    OpenAIRE

    CHRISTOPH PERLETH; KURT A. HELLER

    2008-01-01

    After a brief introduction the theoretical basis of the Munich High Ability Test-Battery (MHBT) will be outlined in the first part of the article. The MHBT has been developed in the framework of the Munich longitudinal study of giftedness and talent. The MHBT includes not only cognitive predictors measuring several dimensions and types of giftedness concerning intellectual, creative or social abilities etc., but also giftedness-relevant non-cognitive personality and social moderators measurin...

  20. [BOUGE-fitness test battery: health-related field-based fitness tests assessment in children and adolescents].

    Science.gov (United States)

    Vanhelst, J; Béghin, L; Czaplicki, G; Ulmer, Z

    2014-01-01

    Physical fitness is an important determinant of global health in children and adolescents. Key components of physical fitness include cardiorespiratory fitness, flexibility, speed, and muscular and endurance strength. The school environment provides a great opportunity to assess the physical fitness level in children and adolescents. The french national program "Bouge... Une priorité pour ta santé! "(Move ... A priority for your health!) aims to assess the physical fitness of children and adolescents aged 6 to 18 years old in French schools. The aim of this paper is to describe the interest to assess different health-related physical fitness components. It presents the chosen tests within said battery for children and adolescents and explains how the battery was conceived. The health-related physical fitness tests included in "BOUGE" were chosen for their validity, reliability, low cost and feasibility for all schools.

  1. Mapping affected territory of anterior/posterior inferior cerebellar artery infarction using a vestibular test battery.

    Science.gov (United States)

    Weng, Yu-Cheng; Young, Yi-Ho

    2014-03-01

    Although the affected territory in the posterior/anterior inferior cerebellar artery (PICA/AICA) infarction could not be meticulously demonstrated by magnetic resonance imaging (MRI), it could be picked up by the results of a vestibular test battery comprising caloric, ocular vestibular evoked myogenic potential (oVEMP), and cervical VEMP (cVEMP) tests. This study applied audiometry and caloric, oVEMP, and cVEMP tests to map affected territory in patients with PICA/AICA infarction. Fourteen patients, including 11 with PICA infarction and 3 with AICA infarction, were enrolled in this study during the last 8 years. Each patient underwent audiometry, caloric test, oVEMP test, and cVEMP test. In the PICA group, 8 (36%) of 22 ears had a mean hearing level >25 dB. All six ears (100%) in the AICA group had abnormal hearing, and thus both groups revealed a significant difference. Conversely, significant differences were not observed in the vestibular test battery between the PICA and AICA groups. MRI demonstrated infarction at the brainstem for six patients, while one patient also had cerebellar involvement, indicated by loss of visual suppression on caloric nystagmus. Six patients showed infarction at the cerebellum, and four of them had brainstem affliction based on abnormal oVEMP/cVEMP test results.

  2. Seismic-fragility tests of new and accelerated-aged Class 1E battery cells

    International Nuclear Information System (INIS)

    Bonzon, L.L.; Janis, W.J.; Black, D.A.; Paulsen, G.A.

    1987-01-01

    The seismic-fragility response of naturally-aged nuclear station safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and thresholds and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the potential survivability of a battery given a seismic event. Prior reports in this series discussed the seismic-fragility tests and results for three specific naturally-aged cell types: 12-year old NCX-2250, 10-year old LCU-13, and 10-year old FHC-19. This report focuses on the complementary approach, namely, the seismic-fragility response of accelerated-aged batteries. Of particular interest is the degree to which such approaches accurately reproduce the actual failure modes and thresholds. In these tests the significant aging effects observed, in terms of seismic survivability, were: embrittlement of cell cases, positive bus material and positive plate grids; and excessive sulphation of positive plate active material causing hardening and expansion of positive plates. The IEEE Standard 535 accelerated aging method successfully reproduced seismically significant aging effects in new cells but accelerated grid embrittlement an estimated five years beyond the conditional age of other components

  3. Developing a Test Battery to assess Determinants of Marital Relationship Satisfaction in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Nadia Al Tamimi

    2009-12-01

    Full Text Available A sample of 50 wives and 50 husbands from Saudi Arabia completed a battery of scales assessing different aspects of couple relationship functioning which had been translated from English to Arabic. The selection of measures was based on the Vulnerability-Stress-Adaptation Model (VSA, Karney & Bradbury, 1995 and included measures of partner attachment, conflict behaviour, and relationship with members of the family-in-law as predictors and marital satisfaction as criterion variable. All scales of the test battery showed acceptable reliability. The newly developed conflict behaviour scale consisted of three theoretically meaningful factors (Positive behaviour, Negative behaviour, and Abuse. All instruments showed evidence for convergent validity and contributed significantly to the prediction of relationship satisfaction. The results showed in general a similar pattern of correlations in Saudi Arabia as previous studies in Western countries.

  4. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  5. Cycle life test. Evaluation program for secondary spacecraft cells. [performance tests on silver zinc batteries, silver cadmium batteries, and nickel cadmium batteries

    Science.gov (United States)

    Harkness, J. D.

    1976-01-01

    Considerable research is being done to find more efficient and reliable means of starting electrical energy for orbiting satellites. Rechargeable cells offer one such means. A test program is described which has been established in order to further the evaluation of certain types of cells and to obtain performance and failure data as an aid to their continued improvement. The purpose of the program is to determine the cycling performance capabilities of packs of cells under different load and temperature conditions. The various kinds of cells tested were nickel-cadmium, silver-cadmium, and silver-zinc sealed cells. A summary of the results of the life cycling program is given in this report.

  6. Testing of the Eagle-Picher nickel-iron, the Globe ISOA lead-acid, and the Westinghouse nickel-iron battery subsystems in an electric-vehicle environment

    Science.gov (United States)

    Hewitt, R.; Bryant, J.

    1982-07-01

    Three full size developmental batteries were tested with electric vehicles; two nickel-iron batteries and a lead-acid battery. Constant speed and driving schedule tests were done on a chassis dynamometer. Several aspects of battery performance were evaluated for capacity, recharge efficiency, voltage response, and self discharge. Each of these three batteries exhibited some strengths and some weaknesses.

  7. Between-Day Reliability and Usefulness of a Fitness Testing Battery in Youth Sport Athletes: Reference Data for Practitioners

    Science.gov (United States)

    Sawczuk, Thomas; Jones, Ben; Scantlebury, Sean; Weakley, Jonathan; Read, Dale; Costello, Nessan; Darrall-Jones, Joshua David; Stokes, Keith; Till, Kevin

    2018-01-01

    This study aimed to evaluate the between-day reliability and usefulness of a fitness testing battery in a group of youth sport athletes. Fifty-nine youth sport athletes (age = 17.3 ± 0.7 years) undertook a fitness testing battery including the isometric mid-thigh pull, counter-movement jump, 5-40 m sprint splits, and the 5-0-5 change of direction…

  8. Validation of a Paper and Pencil Test Battery for the Diagnosis of Minimal Hepatic Encephalopathy in Korea.

    Science.gov (United States)

    Jeong, Jae Yoon; Jun, Dae Won; Bai, Daiseg; Kim, Ji Yean; Sohn, Joo Hyun; Ahn, Sang Bong; Kim, Sang Gyune; Kim, Tae Yeob; Kim, Hyoung Su; Jeong, Soung Won; Cho, Yong Kyun; Song, Do Seon; Kim, Hee Yeon; Jung, Young Kul; Yoon, Eileen L

    2017-09-01

    The aim of this study was to validate a new paper and pencil test battery to diagnose minimal hepatic encephalopathy (MHE) in Korea. A new paper and pencil test battery was composed of number connection test-A (NCT-A), number connection test-B (NCT-B), digit span test (DST), and symbol digit modality test (SDMT). The norm of the new test was based on 315 healthy individuals between the ages of 20 and 70 years old. Another 63 healthy subjects (n = 31) and cirrhosis patients (n = 32) were included as a validation cohort. All participants completed the new paper and pencil test, a critical flicker frequency (CFF) test and computerized cognitive function test (visual continuous performance test [CPT]). The scores on the NCT-A and NCT-B increased but those of DST and SDMT decreased according to age. Twelve of the cirrhotic patients (37.5%) were diagnosed with MHE based on the new paper and pencil test battery. The total score of the paper and pencil test battery showed good positive correlation with the CFF (r = 0.551, P computer base cognitive test decreased significantly in patients with MHE compared to those without MHE. Test-retest reliability was comparable. In conclusion, the new paper and pencil test battery including NCT-A, NCT-B, DST, and SDMT showed good correlation with neuropsychological tests. This new paper and pencil test battery could help to discriminate patients with impaired cognitive function in cirrhosis (registered at Clinical Research Information Service [CRIS], https://cris.nih.go.kr/cris, KCT0000955). © 2017 The Korean Academy of Medical Sciences.

  9. A hierarchical model of factors influencing a battery of agility tests.

    Science.gov (United States)

    Naylor, J; Greig, M

    2015-11-01

    The aim of this study was to investigate the hierarchical contributions of anthropometry, strength and cognition to a battery of prescriptive and reactive agility tests. Nineteen participants (mean±S.D.; age:22.1±1.9 years; height: 182.9±5.5 cm; body mass: 77±4.9 kg) completed four agility tests: a prescriptive linear sprint, a prescriptive change-of-direction sprint, a reactive change-of-direction sprint, and a reactive linear deceleration test. Anthropometric variables included body fat percentage and thigh girth. Strength was quantified as the peak eccentric hamstring torque at 180, 300, and 60°·s-1. Mean reaction time and accuracy in the Stroop word-colour Test was used to assess perceptual and decision making factors. There was little evidence of intertest correlation with the strongest relationship observed between 10 m sprint and t-test performance (r2=0.49, Pagility, accounting for a maximum 23% (P=0.12) in the prescriptive change-of-direction test. Cognitive measures had a stronger correlation with the reactive (rather than prescriptive) agility tests, with a maximum 33% (P=0.04) of variance accounted for in the reactive change-of-direction test. Eccentric hamstring strength accounted for 62% (P=0.01) of the variance in the prescriptive change-of-direction test. Hierarchical ordering of the agility tests revealed that eccentric hamstring strength was the primary predictor in 3 of the 4 tests, with cognitive accuracy the next most common predictor. There is little evidence of inter-test correlation across a battery of agility tests. Eccentric hamstring strength and decision making accuracy are the most common predictors of agility performance.

  10. Accelerated Lifetime Testing Methodology for Lifetime Estimation of Lithium-ion Batteries used in Augmented Wind Power Plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina

    2014-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium ion batteries. The results obtained at the end of the accelerated ageing process were used for the parametrization of a performance-degradation lifetime model, which is able to predict...... was validated by running a verification stage of the lifetime model, where Lithium-ion battery cells were tested at normal operating conditions using an application specific mission profile....

  11. Fabrication, Testing, and Simulation of All-Solid-State Three-Dimensional Li-Ion Batteries.

    Science.gov (United States)

    Talin, A Alec; Ruzmetov, Dmitry; Kolmakov, Andrei; McKelvey, Kim; Ware, Nicholas; El Gabaly, Farid; Dunn, Bruce; White, Henry S

    2016-11-30

    Demonstration of three-dimensional all-solid-state Li-ion batteries (3D SSLIBs) has been a long-standing goal for numerous researchers in the battery community interested in developing high power and high areal energy density storage solutions for a variety of applications. Ideally, the 3D geometry maximizes the volume of active material per unit area, while keeping its thickness small to allow for fast Li diffusion. In this paper, we describe experimental testing and simulation of 3D SSLIBs fabricated using materials and thin-film deposition methods compatible with semiconductor device processing. These 3D SSLIBs consist of Si microcolumns onto which the battery layers are sequentially deposited using physical vapor deposition. The power performance of the 3D SSLIBs lags significantly behind that of similarly prepared planar SSLIBs. Analysis of the experimental results using finite element modeling indicates that the origin of the poor power performance is the structural inhomogeneity of the 3D SSLIB, coupled with low electrolyte ionic conductivity and diffusion rate in the cathode, which lead to highly nonuniform internal current density distribution and poor cathode utilization.

  12. Reducing chronic visuo-spatial neglect following right hemisphere stroke through instrument playing

    Directory of Open Access Journals (Sweden)

    Rebeka eBodak

    2014-06-01

    Full Text Available Unilateral visuo-spatial neglect is a neuropsychological syndrome commonly resulting from right hemisphere strokes at the temporo-parietal junction of the infero-posterior parietal cortex. Neglect is characterised by reduced awareness of stimuli presented on patients’ contralesional side of space and has previously been shown to be improved by a number of motivational influences, including listening to preferred music and numerical sequence completion. Here we examined whether playing musical sequences on chime bars – an instrument with a horizontal alignment – would bring about clinically significant improvement in chronic neglect.Two left neglect patients completed an intervention comprising four weekly 30-minute music sessions involving playing scales and familiar melodies on chime bars from right to left. Two cancellation tests (Mesulam shape, BIT star, the line bisection test, and the neglect subtest from the computerised TAP (Test for Attentional Performance battery were administered three times during a preliminary baseline phase, before and after each music session during the rehabilitation phase to investigate short-term effects, as well as one week after the last intervention session to investigate whether any effects would persist.Both patients demonstrated significant short-term and longer-lasting improvements on the Mesulam shape cancellation test. One patient also showed longer-lasting effects on the BIT star cancellation test and scored in the normal range one week after the intervention. These findings provide preliminary evidence that active music-making may help neglect patients attend more to their affected side.

  13. Indices of cognitive function measured in rugby union players using a computer-based test battery.

    Science.gov (United States)

    MacDonald, Luke A; Minahan, Clare L

    2016-09-01

    The purpose of this study was to investigate the intra- and inter-day reliability of cognitive performance using a computer-based test battery in team-sport athletes. Eighteen elite male rugby union players (age: 19 ± 0.5 years) performed three experimental trials (T1, T2 and T3) of the test battery: T1 and T2 on the same day and T3, on the following day, 24 h later. The test battery comprised of four cognitive tests assessing the cognitive domains of executive function (Groton Maze Learning Task), psychomotor function (Detection Task), vigilance (Identification Task), visual learning and memory (One Card Learning Task). The intraclass correlation coefficients (ICCs) for the Detection Task, the Identification Task and the One Card Learning Task performance variables ranged from 0.75 to 0.92 when comparing T1 to T2 to assess intraday reliability, and 0.76 to 0.83 when comparing T1 and T3 to assess inter-day reliability. The ICCs for the Groton Maze Learning Task intra- and inter-day reliability were 0.67 and 0.57, respectively. We concluded that the Detection Task, the Identification Task and the One Card Learning Task are reliable measures of psychomotor function, vigilance, visual learning and memory in rugby union players. The reliability of the Groton Maze Learning Task is questionable (mean coefficient of variation (CV) = 19.4%) and, therefore, results should be interpreted with caution.

  14. NIH Toolbox Cognition Battery (NIHTB-CB): list sorting test to measure working memory.

    Science.gov (United States)

    Tulsky, David S; Carlozzi, Noelle; Chiaravalloti, Nancy D; Beaumont, Jennifer L; Kisala, Pamela A; Mungas, Dan; Conway, Kevin; Gershon, Richard

    2014-07-01

    The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support for the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relationship between the List Sorting Test and general executive function has yet to be determined.

  15. Targeting as the basis for pre-test market of lithium-ion battery

    Science.gov (United States)

    Yuniaristanto, Zakaria, R.; Saputri, V. H. L.; Sutopo, W.; Kadir, E. A.

    2017-11-01

    This article discusses about market segmentation and targeting as a first step in pre-test market of a new technology. The benefits of targeting towards pre-test market are pre-test market can be conducted to focus on selected target markets so there is no bias during the pre-test market. In determining the target market then do some surveys to identify the state of market in the future, so that the marketing process is not misplaced. Lithium ion battery which is commercialized through start-up companies is the case study. This start-up companies must be able to respond the changes and bring in customers as well as maintain them so that companies can survive and evolve to achieve its objectives. The research aims to determine market segments and target market effectively. Marketing strategy (segmentation and targeting) is used to make questionnaire and cluster analysis in data processing. Respondents were selected by purposive sampling and have obtained data as many as 80 samples. As the results study, there are three segments for lithium ion battery with their own distinguished characteristics and there are two segments that can be used as the target market for the company.

  16. Influence of different open circuit voltage tests on state of charge online estimation for lithium-ion batteries

    International Nuclear Information System (INIS)

    Zheng, Fangdan; Xing, Yinjiao; Jiang, Jiuchun; Sun, Bingxiang; Kim, Jonghoon; Pecht, Michael

    2016-01-01

    Highlights: • Two common tests for observing battery open circuit voltage performance are compared. • The temperature dependency of the OCV-SOC relationship is investigated. • Two estimators are evaluated in terms of accuracy and robustness for estimating battery SOC. • The incremental OCV test is better to predetermine the OCV-SOCs for SOC online estimation. - Abstract: Battery state of charge (SOC) estimation is a crucial function of battery management systems (BMSs), since accurate estimated SOC is critical to ensure the safety and reliability of electric vehicles. A widely used technique for SOC estimation is based on online inference of battery open circuit voltage (OCV). Low-current OCV and incremental OCV tests are two common methods to observe the OCV-SOC relationship, which is an important element of the SOC estimation technique. In this paper, two OCV tests are run at three different temperatures and based on which, two SOC estimators are compared and evaluated in terms of tracking accuracy, convergence time, and robustness for online estimating battery SOC. The temperature dependency of the OCV-SOC relationship is investigated and its influence on SOC estimation results is discussed. In addition, four dynamic tests are presented, one for estimator parameter identification and the other three for estimator performance evaluation. The comparison results show that estimator 2 (based on the incremental OCV test) has higher tracking accuracy and is more robust against varied loading conditions and different initial values of SOC than estimator 1 (based on the low-current OCV test) with regard to ambient temperature. Therefore, the incremental OCV test is recommended for predetermining the OCV-SOCs for battery SOC online estimation in BMSs.

  17. Issues in development of the test battery for Australian sign language morphology and syntax.

    Science.gov (United States)

    Schembri, Adam; Wigglesworth, Gillian; Johnston, Trevor; Leigh, Greg; Adam, Robert; Barker, Roz

    2002-01-01

    In this article, we outline the initial stages in development of an assessment instrument for Australian Sign Language and explore issues involved in the development of such a test. We first briefly describe the instruments currently available for assessing grammatical skills in Australian Sign Language and discuss the need for a more objective measure. We then describe our adaptation of an existing American Sign Language test, the Test Battery for American Sign Language Morphology and Syntax. Finally, this article presents some of the data collected from a group of deaf native signers. These data are used to demonstrate the range of variability in key grammatical features of Australian Sign Language and to raise methodological issues associated with signed language test design.

  18. Factorial Structure of the Movement Assessment Battery for Children Test-Second Edition in Preschool Children.

    Science.gov (United States)

    Psotta, Rudolf; Brom, Ondřej

    2016-12-01

    The Movement Assessment Battery for Children-Second Edition is one of the most frequently used tests for assessment of the fundamental motor skills in children. However, there is the question which sensorimotor functions are really captured by the tasks involved in the test for the preschool (3-6 years) children (age band 1). The aim of the study was to examine the factorial structure of the age band 1 test. Results of the testing by the age band 1 in a sample of three- to- six-year-old children (N = 399; 202 boys, 197 girls) were put to confirmatory factor analysis. The results of the study proved the three-specific factor structure of the age band 1. Thus, within the assessment of a child's overall motor proficiency, the motor competence profile including manual dexterity, aiming and catching, and balance abilities can be identified in three- to six-year-old children. © The Author(s) 2016.

  19. Lead paste recycling based on conversion into battery grade oxides. Electrochemical tests and industrial production of new batteries

    Science.gov (United States)

    Fusillo, G.; Rosestolato, D.; Scura, F.; Cattarin, S.; Mattarozzi, L.; Guerriero, P.; Gambirasi, A.; Brianese, N.; Staiti, P.; Guerriero, R.; La Sala, G.

    2018-03-01

    We present the preparation and characterization of pure lead monoxide obtained through recycling of the lead paste recovered from exhausted lead acid batteries. The recycling is based on a hydrometallurgical procedure reported in a STC Patent, that includes simple chemical operations (desulphurisation, leaching, precipitation, filtration) and a final thermal conversion. Materials obtained by treatment at 600 °C consist predominantly of β-PbO. The electrochemical behaviour of Positive Active Mass (PAM) prepared from different materials (or mixtures) is then investigated and compared. An optimized oxide material, obtained by prolonged (8 h) thermal treatment at 600 °C, consists of pure β-PbO and appears suitable for preparation of battery elements, alone or in mixture with a small fraction (10%-30%) of traditional industrial leady oxide. The resulting battery performances are similar to those obtained from pure leady oxide. In comparison with traditional recycling processes, the proposed method guarantees lower energy consumption, limited environmental impact and reduced operating risk for industry workers.

  20. Electric Toothbrush Assembler (elec. equip.) 723.884--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  1. Tomato Peeler (can. & preserv.) 529.887 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  2. Carding Machine Operator 8-27.77 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  3. Assembler, Oil Filters (auto mfg.) 739.887--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  4. Sales Clerk (ret. tr.) 1-70.10--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  5. Creditman (ret. tr.; whole tr.) 0-85.11--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  6. Salesperson, General (ret. tr.) 1-75.71--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  7. Meat Cutter (ret. tr.; whole. tr.) 316.884--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  8. Compression-Molding-Machine Tender (fabric. plastics prod.) 556.885--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  9. Candy Packer (confection) 8-05.21--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  10. Candy-Wrapping-Machine Operator (Confection) 920.885-034 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  11. Room Clerk (hotel and rest.) 1-07.60--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  12. Autoclave Operator (chem.) 4-52.711--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  13. Processor, Solid Propellant (chem.) 6-52.773--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  14. A pilot evaluation of a computer-based psychometric test battery designed to detect impairment in patients with cirrhosis.

    Science.gov (United States)

    Cook, Nicola A; Kim, Jin Un; Pasha, Yasmin; Crossey, Mary Me; Schembri, Adrian J; Harel, Brian T; Kimhofer, Torben; Taylor-Robinson, Simon D

    2017-01-01

    Psychometric testing is used to identify patients with cirrhosis who have developed hepatic encephalopathy (HE). Most batteries consist of a series of paper-and-pencil tests, which are cumbersome for most clinicians. A modern, easy-to-use, computer-based battery would be a helpful clinical tool, given that in its minimal form, HE has an impact on both patients' quality of life and the ability to drive and operate machinery (with societal consequences). We compared the Cogstate™ computer battery testing with the Psychometric Hepatic Encephalopathy Score (PHES) tests, with a view to simplify the diagnosis. This was a prospective study of 27 patients with histologically proven cirrhosis. An analysis of psychometric testing was performed using accuracy of task performance and speed of completion as primary variables to create a correlation matrix. A stepwise linear regression analysis was performed with backward elimination, using analysis of variance. Strong correlations were found between the international shopping list, international shopping list delayed recall of Cogstate and the PHES digit symbol test. The Shopping List Tasks were the only tasks that consistently had P values of battery correlated very strongly with the digit symbol component of PHES in discriminating severity of HE. These findings would indicate that components of the current PHES battery with the international shopping list tasks of Cogstate would be discriminant and have the potential to be used easily in clinical practice.

  15. Bilingualism and performance on two widely used developmental neuropsychological test batteries.

    Science.gov (United States)

    Karlsson, Linda C; Soveri, Anna; Räsänen, Pekka; Kärnä, Antti; Delatte, Sonia; Lagerström, Emma; Mård, Lena; Steffansson, Mikaela; Lehtonen, Minna; Laine, Matti

    2015-01-01

    The present study investigated the effect of bilingualism on the two widely used developmental neuropsychological test batteries Wechsler Intelligence Scale for Children - Fourth Edition (WISC-IV) and A Developmental Neuropsychological Assessment, Second Edition (NEPSY-II) in children. The sample consisted of 100 Finland-Swedish children in two age groups. About half (n = 52) of the participants were early simultaneous bilinguals, and the other half (n = 48) were monolinguals. As no Finland-Swedish versions of the tests are available at the moment, both tests were translated and adapted to suit this population. The results revealed no difference in the performance between bilingual and monolingual children. This speaks against a cognitive advantage in bilingual children and indicates that development of separate norms for monolingual and bilingual children is not needed for clinical use.

  16. Reliability of a new test battery for fitness assessment of the European Astronaut corps.

    Science.gov (United States)

    Petersen, Nora; Thieschäfer, Lutz; Ploutz-Snyder, Lori; Damann, Volker; Mester, Joachim

    2015-01-01

    To optimise health for space missions, European astronauts follow specific conditioning programs before, during and after their flights. To evaluate the effectiveness of these programs, the European Space Agency conducts an Astronaut Fitness Assessment (AFA), but the test-retest reliability of elements within it remains unexamined. The reliability study described here presents a scientific basis for implementing the AFA, but also highlights challenges faced by operational teams supporting humans in such unique environments, especially with respect to health and fitness monitoring of crew members travelling not only into space, but also across the world. The AFA tests assessed parameters known to be affected by prolonged exposure to microgravity: aerobic capacity (VO2max), muscular strength (one repetition max, 1 RM) and power (vertical jumps), core stability, flexibility and balance. Intraclass correlation coefficients (ICC3.1), standard error of measurement and coefficient of variation were used to assess relative and absolute test-retest reliability. Squat and bench 1 RM (ICC3.1 = 0.94-0.99), hip flexion (ICC3.1 = 0.99) and left and right handgrip strength (ICC3.1 = 0.95 and 0.97), showed the highest test-retest reliability, followed by VO2max (ICC3.1 = 0.91), core strength (ICC3.1 = 0.78-0.89), hip extension (ICC3.1 = 0.63), the countermeasure (ICC3.1 = 0.76) and squat (ICC3.1 = 0.63) jumps, and single right- and left-leg jump height (ICC3.1 = 0.51 and 0.14). For balance, relative reliability ranged from ICC3.1 = 0.78 for path length (two legs, head tilted back, eyes open) to ICC3.1 = 0.04 for average rotation velocity (one leg, eyes closed). In a small sample (n = 8) of young, healthy individuals, the AFA battery of tests demonstrated acceptable test-retest reliability for most parameters except some balance and single-leg jump tasks. These findings suggest that, for the application with astronauts, most AFA tests appear appropriate to

  17. Development and Testing of an UltraBattery-Equipped Honda Civic

    Energy Technology Data Exchange (ETDEWEB)

    Donald Karner

    2012-04-01

    The UltraBattery retrofit project DP1.8 and Carbon Enriched project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy (DOE) and the Advanced Lead Acid Battery Consortium (ALABC), are to demonstrate the suitability of advanced lead battery technology in Hybrid Electrical Vehicles (HEVs).

  18. Design and Construction of a Test Bench to Characterize Efficiency and Reliability of High Voltage Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Blank, Tobias; Thomas, Stephan; Roggendorf, Christoph

    2010-01-01

    system efficiency. High voltage batteries may be advantageous for future medium voltage DC-grids as well. In all cases, high availability and reliability is indispensable. Investigations on the operating behavior of such systems are needed. For this purpose, a test bench for high voltage storage systems...... was built to analyze these processes for different battery technologies. A special safety infrastructure for the test bench was developed due to the high voltage and the storable energy of approximately 120 kWh. This paper presents the layout of the test bench for analyzing high voltage batteries with about...... 4,300 volts including all components, the safety requirements with the resultant safety circuit and the aim of the investigations to be performed with the test bench....

  19. Selected test results from the LiFeBatt iron phosphate Li-ion battery.

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, David T.; Hund, Thomas D.

    2008-09-01

    In this paper the performance of the LiFeBatt Li-ion cell was measured using a number of tests including capacity measurements, capacity as a function of temperature, ohmic resistance, spectral impedance, high power partial state of charge (PSOC) pulsed cycling, pulse power measurements, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the iron phosphate Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, and wind farm energy smoothing. Test results have indicated that the LiFeBatt battery technology can function up to a 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h discharge rate (1C). The utility PSOC cycle test at up to the 4C{sub 1} pulse rate completed 8,394 PSOC pulsed cycles with a gradual loss in capacity of 10 to 15% depending on how the capacity loss is calculated. The majority of the capacity loss occurred during the initial 2,000 cycles, so it is projected that the LiFeBatt should PSOC cycle well beyond 8,394 cycles with less than 20% capacity loss. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were only very small changes after cycling. Finally, at a 1C charge rate, the over charge/voltage abuse test resulted in the cell venting electrolyte at 110 C after 30 minutes and then open-circuiting at 120 C with no sparks, fire, or voltage across the cell.

  20. Internal Structure and Partial Invariance across Gender in the Spanish Version of the Reasoning Test Battery.

    Science.gov (United States)

    Elosua, Paula; Mujika, Josu

    2015-10-13

    The Reasoning Test Battery (BPR) is an instrument built on theories of the hierarchical organization of cognitive abilities and therefore consists of different tasks related with abstract, numerical, verbal, practical, spatial and mechanical reasoning. It was originally created in Belgium and later adapted to Portuguese. There are three forms of the battery consisting of different items and scales which cover an age range from 9 to 22. This paper focuses on the adaptation of the BPR to Spanish, and analyzes different aspects of its internal structure: (a) exploratory item factor analysis was applied to assess the presence of a dominant factor for each partial scale; (b) the general underlined model was evaluated through confirmatory factor analysis, and (c) factorial invariance across gender was studied. The sample consisted of 2624 Spanish students. The results concluded the presence of a general factor beyond the scales, with equivalent values for men and women, and gender differences in the factorial structure which affect the numerical reasoning, abstract reasoning and mechanical reasoning scales.

  1. JPL's electric and hybrid vehicles project: Project activities and preliminary test results. [power conditioning and battery charge efficiency

    Science.gov (United States)

    Barber, T. A.

    1980-01-01

    Efforts to achieve a 100 mile urban range, to reduce petroleum usage 40% to 70%, and to commercialize battery technology are discussed with emphasis on an all plastic body, four passenger car that is flywheel assisted and battery powered, and on an all metal body, four passenger car with front wheel drive and front motor. For the near term case, a parallel hybrid in which the electric motor and the internal combustion engine may directly power the drive wheels, is preferred to a series design. A five passenger car in which the electric motor and the gasoline engine both feed into the same transmission is discussed. Upgraded demonstration vehicles were tested using advanced lead acid, nickel zinc, nickel iron, and zinc chloride batteries to determine maximum acceleration, constant speed, and battery behavior. The near term batteries demonstrated significant improvement relative to current lead acid batteries. The increase in range was due to improved energy density, and ampere hour capacity, with relatively 1 small weight and volume differences.

  2. Battery Usage and Thermal Performance of the Toyota Prius and Honda Insight for Various Chassis Dynamometer Test Procedures: Preprint

    International Nuclear Information System (INIS)

    Kelly, K. J.; Mihalic, M.; Zolot, M.

    2001-01-01

    This study describes the results from the National Renewable Energy Laboratory's (NREL) chassis dynamometer testing of a 2000 model year Honda Insight and 2001 model year Toyota Prius. The tests were conducted for the purpose of evaluating the battery thermal performance, assessing the impact of air conditioning on fuel economy and emissions, and providing information for NREL's Advanced Vehicle Simulator (ADVISOR)

  3. The Performance of Learning Disabled Children on the Kaufman Assessment Battery for Children and the Bender-Gestalt Test.

    Science.gov (United States)

    Haddad, Frederick A.

    1986-01-01

    Results of the Kaufman Assessment Battery for Children (K-ABC) and Bender-Gestalt Test were compared for a sample of learning disabled children that included 24 blacks and 24 whites; mean age 9 years. A significant correlation coefficient was found between the K-ABC Simultaneous Scale and the Bender-Gestalt Test error score. Implications of these…

  4. Electrothermal impedance spectroscopy measurement on high power LiMO2/Li4Ti5O12 battery cell with low bandwidth test setup

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Loan; Stanciu, Tiberiu

    2015-01-01

    Modern lithium-ion batteries, like LiMO2/Li4Ti5O12 chemistry, are having very high power capability, which drives the need for precise thermal modelling of the battery. Battery thermal models are required to avoid possible safety issues (thermal runaways, high-temperature gradients) but also for ......-bandwidth and high-current capability for large format battery cells. Thus, this paper evaluates the possibility and accuracy of performing ETIS measurements with a standard battery test station (or bidirectional power supply) with low-bandwidth....

  5. The Swiss Army physical fitness test battery predicts risk of overuse injuries among recruits.

    Science.gov (United States)

    Wyss, T; Von Vigier, R O; Frey, F; Mäder, U

    2012-10-01

    The aim of this study was to quantify the discriminative power of physical performance tests to recognize conscripts with enhanced risk of acute and overuse injuries in specific, physically demanding occupational specialties of the Swiss Army. The five performance tests investigated represent the Swiss Army Physical Fitness Test Battery. Physical fitness performances were assessed during recruitment procedures prior to military service, and injury occurrences were assessed during 18 weeks of boot camp. Complete fitness and injury data of 459 volunteers from four military occupational specialties were collected. Discriminative power of volunteers' aerobic endurance capacity, trunk muscle fitness, muscle power of upper and lower extremities, and balance for predicting risk of acute injuries and for predicting risk of overuse injuries was calculated using receiver operating characteristic curve analysis. The presented fitness tests had no discriminative power for predicting the risk of acute injuries. However, the trunk muscle fitness test was discriminative in predicting overuse injuries in all four military occupational specialties, progressive endurance run in three, balance test in two, and standing long jump in one. Only the seated shot put had no significant power for predicting overuse injuries in all four study groups. However, for different occupational specialties, different fitness parameters were discriminative to predict overuse injuries. It is possible to conclude that the fitness tests used allow detection of conscripts with enhanced overuse injury risk in physically demanding occupational specialties and therefore provide an indicator to select suitable personnel for physically demanding jobs in a military organization.

  6. Mechanisms of change: Testing how preventative interventions impact psychological and physiological stress functioning in mothers in neglectful families.

    Science.gov (United States)

    Toth, Sheree L; Sturge-Apple, Melissa L; Rogosch, Fred A; Cicchetti, Dante

    2015-11-01

    The present study applies a multilevel approach to an examination of the effect of two randomized preventive interventions with mothers in neglectful families who are also contending with elevated levels of impoverishment and ecological risk. Specifically, we examined how participation in either child-parent psychotherapy (CPP) or psychoeducational parenting intervention (PPI) was associated with reductions in maternal psychological parenting stress and in turn physiological stress system functioning when compared to mothers involved in standard community services as well as a demographic comparison group of nonmaltreating mothers. The resulting group sizes in the current investigation were 44 for CPP, 34 for PPI, 27 for community services, and 52 for nonmaltreating mothers. Mothers and their 13-month-old infants were randomly assigned to intervention group at baseline. Mothers completed assessments on stress within the parenting role at baseline and postintervention. Basal cortisol was sampled at postintervention and 1-year follow-up. Latent difference score analyses examined change in these constructs over time. Results suggested that mothers within the CPP intervention experienced significant declines in child-related parenting stress, while mothers in the PPI intervention reported declines in parent-related parenting stress. In turn, significant decreases in stress within the CPP mothers were further associated with adaptive basal cortisol functioning at 1-year postintervention. The results highlight the value of delineating how participation in preventive interventions aimed at ameliorating child maltreatment in neglectful families within the context of poverty may operate through improvements in psychological and physiological stress functioning. Findings are discussed with respect to the importance of multilevel assessments of intervention process and outcome.

  7. Initial validation of a web-based self-administered neuropsychological test battery for older adults and seniors.

    Science.gov (United States)

    Hansen, Tor Ivar; Haferstrom, Elise Christina D; Brunner, Jan F; Lehn, Hanne; Håberg, Asta Kristine

    2015-01-01

    Computerized neuropsychological tests are effective in assessing different cognitive domains, but are often limited by the need of proprietary hardware and technical staff. Web-based tests can be more accessible and flexible. We aimed to investigate validity, effects of computer familiarity, education, and age, and the feasibility of a new web-based self-administered neuropsychological test battery (Memoro) in older adults and seniors. A total of 62 (37 female) participants (mean age 60.7 years) completed the Memoro web-based neuropsychological test battery and a traditional battery composed of similar tests intended to measure the same cognitive constructs. Participants were assessed on computer familiarity and how they experienced the two batteries. To properly test the factor structure of Memoro, an additional factor analysis in 218 individuals from the HUNT population was performed. Comparing Memoro to traditional tests, we observed good concurrent validity (r = .49-.63). The performance on the traditional and Memoro test battery was consistent, but differences in raw scores were observed with higher scores on verbal memory and lower in spatial memory in Memoro. Factor analysis indicated two factors: verbal and spatial memory. There were no correlations between test performance and computer familiarity after adjustment for age or age and education. Subjects reported that they preferred web-based testing as it allowed them to set their own pace, and they did not feel scrutinized by an administrator. Memoro showed good concurrent validity compared to neuropsychological tests measuring similar cognitive constructs. Based on the current results, Memoro appears to be a tool that can be used to assess cognitive function in older and senior adults. Further work is necessary to ascertain its validity and reliability.

  8. Test-retest reliability and practice effects of the computerized neuropsychological test battery CNS Vital Signs : Evaluation in a Dutch healthy sample

    NARCIS (Netherlands)

    van der Linden, S.D.; Rijnen, S.J.M.; Emons, W.H.M.; Sitskoorn, M.M.; Gehring, K.

    2017-01-01

    Introduction: CNS Vital Signs (CNS VS) is a computerized neuropsychological test battery that is translated into many languages. Test-retest reliability and potential practice effects of CNS VS were evaluated. Method: Dutch healthy participants were tested with CNS VS (T0), and retested after 3 (T1)

  9. Evaluation of a Test Battery to Assess Perception of Music in Children With Cochlear Implants.

    Science.gov (United States)

    Roy, Alexis T; Scattergood-Keepper, Lindsay; Carver, Courtney; Jiradejvong, Patpong; Butler, Caty; Limb, Charles J

    2014-06-01

    A number of studies have investigated music perception in adult cochlear implant (CI) users. However, little is known about how pediatric CI users perceive and process music, in part because suitable methods for assessing music perception in this population are lacking. Therefore, we developed the Music in Children With Cochlear Implants (MCCI) battery to assess music perception in pediatric CI users younger than 9 years. To pilot test the MCCI on a group of pediatric CI users to determine its feasibility for measuring music perception and to compare performance of CI users with that of normal-hearing (NH) control participants. The pilot test was conducted in an academic tertiary care center. The MCCI evaluated rhythm, pitch, melody, harmony, and timbre perception. For each section, 10 pediatric CI users and 10 NH controls were presented with a pair of stimuli that possibly varied along a single musical element (eg, rhythm). Participants were required to indicate whether the stimuli in the pair were the same or different. Administration of the MCCI. Percentage correct on each section of the MCCI and the aggregate score of all sections by group. The MCCI provided a basic characterization of musical perceptual abilities. In the aggregate, NH controls significantly outperformed CI users in music perception (mean [SD] accuracy for CI users vs NH controls: rhythm, 73% [20%] vs 78% [20%]; pitch, 84% [12%] vs 91% [13%]; melody, 65% [16%] vs 75% [18%]; harmony, 74% [13%] vs 75% [14%]; and timbre, 80% [17%] vs 90% [12%]; repeated-measures analysis of variance, F1,17 = 9.3; P musical stimuli, although not to the extent of their NH peers. The MCCI provided an efficient and user-friendly assessment of music perception in pediatric CI users. This test battery may serve as a valuable tool to evaluate music perceptual abilities of pediatric CI users and measure the effects of interventions.

  10. On the Static Accuracy of Charge-Discharge Units Intended for Electrical Tests of High Capacity Li-ion Batteries

    Science.gov (United States)

    Mizrah, E. A.; Lobanov, D. K.; Kopylov, E. A.; Balakirev, R. V.; Fedchenko, A. S.

    2017-10-01

    Performing of the cycle testing according to the principles of Dynamic Stress Test can significantly reduce the overall time of development and production of batteries, which in turn allows reducing the cost of designing and testing of the spacecraft power systems. Performing of Dynamic Stress Test require special charge-discharge units that allows to perform a full cycle of electrical tests of batteries, including cyclic testing. Providing the required accuracy of measurement and stabilization of certain attributes of Li-ion battery operating modes is one of the problems that arise during thedevelopment of such charge-discharge units. The following attributes are of particular interest: charge and discharge currents, discharge powers, battery voltages. Analysis of the charge-discharge unit as a control system allows evaluating the steady-state stabilization error of the required attributes of the developed device. Moreover, using a digital integrator in the control system of the charge-discharge unit allows providing specified values of steady-state stabilization error of required attributes in different test modes.

  11. U.S. Department of Energy Vehicle Technologies Program: Battery Test Manual For Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Christophersen, Jon P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).

  12. Evaluation of genotoxicity through micronuclei test in workers of car and battery repair garages

    Directory of Open Access Journals (Sweden)

    Martino-Roth M.G.

    2002-01-01

    Full Text Available In this study, the micronuclei test (MNT was applied in exfoliated cells of buccal mucosa, in order to evaluate the genotoxic risk associated with occupational exposure of mechanics, storage battery renovation workers, and car painters. For each individual, 3000 exfoliated buccal cells were analyzed. There was a significantly higher frequency of micronucleated cells (MNC in the exposed workers than in controls. Smoking and drinking habits, age, and working time did not represent significant factors in terms of increasing the production of micronuclei (MN, when the control and the exposed groups were compared. These results allowed to conclude that the studied individuals belong to a risk group and should periodically undergo biological monitoring and proper care.

  13. Test battery for measuring the perception and recognition of facial expressions of emotion

    Science.gov (United States)

    Wilhelm, Oliver; Hildebrandt, Andrea; Manske, Karsten; Schacht, Annekathrin; Sommer, Werner

    2014-01-01

    Despite the importance of perceiving and recognizing facial expressions in everyday life, there is no comprehensive test battery for the multivariate assessment of these abilities. As a first step toward such a compilation, we present 16 tasks that measure the perception and recognition of facial emotion expressions, and data illustrating each task's difficulty and reliability. The scoring of these tasks focuses on either the speed or accuracy of performance. A sample of 269 healthy young adults completed all tasks. In general, accuracy and reaction time measures for emotion-general scores showed acceptable and high estimates of internal consistency and factor reliability. Emotion-specific scores yielded lower reliabilities, yet high enough to encourage further studies with such measures. Analyses of task difficulty revealed that all tasks are suitable for measuring emotion perception and emotion recognition related abilities in normal populations. PMID:24860528

  14. Assessment of Dementia in Individuals with Dual Sensory Loss: Application of a Tactile Test Battery

    Directory of Open Access Journals (Sweden)

    Peter Bruhn

    2018-01-01

    Full Text Available Background/Aims: Individuals with dual sensory loss (DSL are more likely to experience cognitive decline with age than individuals without sensory loss. Other studies have pointed to the challenges in assessing cognitive abilities in individuals with DSL, as most existing instruments rely on use of vision and hearing. The aim of this study was to develop and evaluate a Tactile Test Battery (TTB for cognitive assessment in individuals with DSL. Method: Twenty elderly individuals with DSL, 20 with diagnosed dementia, and 20 without dementia or DSL (controls completed the following tactile tests developed for the present study: Spatial learning, Spatial recall, Tactile form board, Clock reading, and Naming. The participants with dementia and controls also completed the Mini-Mental State Examination (MMSE. Results: Overall, participants with dementia performed significantly worse on the tactile tests than participants with DSL and control participants. No significant differences on the tactile tests were found between participants with DSL and controls. The TTB and MMSE scores correlated significantly. Conclusion: The findings from this study of applying tactile tests for cognitive examination in individuals with DSL are promising. They indicate that symptoms of dementia can be differentiated from symptoms related to DSL.

  15. Ecotoxicological assessment of silica and polystyrene nanoparticles assessed by a multitrophic test battery.

    Science.gov (United States)

    Casado, Maria P; Macken, Ailbhe; Byrne, Hugh J

    2013-01-01

    The acute ecotoxicity of different diameters of silica and polyethyleneimine polystyrene (PS-PEI) nanoparticles (NPs) was assessed on a test battery of aquatic organisms representing different trophic levels. Daphnia magna, Thamnocephalus platyurus, Pseudokirchneriella subcapitata and Vibrio fischeri, were employed in a series of standard acute ecotoxicity tests and work was complemented with two cytotoxicological end points on a rainbow trout gonadal cell line (RTG-2). Physico-chemical characterization of the NPs was performed in the different test media employed, using dynamic light scattering (DLS) and zeta potentiometry. In contrast to silica NPs exposure, for which no effect was observed for concentrations up to 1000 μg ml(-1) for all in vivo aquatic organisms tested, significant toxicity was detected after exposure to PS-PEI NPs at concentrations from 0.40 μg ml(-1) to 416.5 μg ml(-1). Differing sensitivities for each NP diameter for the different organisms were observed as: P. subcapitata≥D. magna>T. platyurus>V. fischeri. The effects observed were dependent in some cases on the NP size, a higher effect being observed for the larger NPs. Finally, cytotoxicity studies showed an effect at the highest concentrations for both sets of NPs which was greater in the case of the PS-PEI NPs. However, as agglomeration and sedimentation of the nanoparticles was observed at these concentrations, the cytotoxicity studies were found not to be a reliable ecotoxicity test model. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Ground testing of the Li-ion batteries in support of JPL's 2003 Mars Exploration Rover Mission

    Science.gov (United States)

    Smart, M. C.; Ratnakumar, B. V.; Ewell, R. C.; Whitcanack, L. D.; Chin, K. B.; Surampudi, S.; Puglia, F.; Gitzendanner, R.

    2005-01-01

    In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(deg)C to +4O(deg)C), withstand long storage periods (e.g., cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the viability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit (RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The testing performed includes, (a) performing initial characterization tests (discharge capacity at different temperatures), (b) simulating the launch conditions, (c) simulating the cruise phase conditions (including trajectory corrections), (d) simulating the entry, decent, and landing pulse load profile (if required to support the pyros) (e) simulating the Mars surface operation mission simulation conditions, as well as, (f) assessing performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by LithiodYardney, Inc.) were demonstrated to far exceed the requirements defined by the mission, and are projected to support an extended mission (> 2 years) with margin to spare.

  17. RehAtt - scanning training for neglect enhanced by multi-sensory stimulation in Virtual Reality.

    Science.gov (United States)

    Fordell, Helena; Bodin, Kenneth; Eklund, Anders; Malm, Jan

    2016-06-01

    There is a lack of effective treatment for neglect. We have developed a new training method, RehAtt™. The objective of this study was to determine whether RehAtt™ improves spatial attention in chronic neglect after stroke. RehAtt™ consists of a computer with monitor, 3D glasses, and a force feedback interface (Robotic pen) giving sensory motor activation to the contra-lesional arm. The software combines visual scanning training with multi-sensory stimulation in 3D virtual reality (VR) game environment. Fifteen stroke patients with chronic neglect (duration > 6 month) had repeated baseline evaluations to confirm stability of symptoms. There were no test-retest effects for any of the tests. Thereafter, all patients trained 15 h in RehAtt™ (3 × 1 h for 5 weeks). A neglect test battery and Catherine Bergego Scale, CBS, were used to assess behavioral outcome after intervention. CBS was also used at a 6-month follow-up. Using repeated measurement analysis improvements due to the training were found for Star cancellation test (p = 0.006), Baking tray task (p VR-method improved spatial attention and showed transfer to improved spatial attention in activities of daily living in chronic neglect. Our results are promising and merit further studies.

  18. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    Science.gov (United States)

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Testing ESL sociopragmatics development and validation of a web-based test battery

    CERN Document Server

    Roever, Carsten; Elder, Catherine

    2014-01-01

    Testing of second language pragmatics has grown as a research area but still suffers from a tension between construct coverage and practicality. In this book, the authors describe the development and validation of a web-based test of second language pragmatics for learners of English. The test has a sociopragmatic orientation and strives for a broad coverage of the construct by assessing learners'' metapragmatic judgments as well as their ability to co-construct discourse. To ensure practicality, the test is delivered online and is scored partially automatically and partially by human raters.

  20. Test-retest reliability and practice effects for the ANAM General Neuropsychological Screening battery.

    Science.gov (United States)

    Vincent, Andrea S; Roebuck-Spencer, Tresa M; Fuenzalida, Eugenia; Gilliland, Kirby

    2018-04-01

    As the use of computer-based neurocognitive assessment is rapidly expanding, the need to systematically study and document key psychometric properties of these measures has become increasingly more salient. To meet this aim, this study examined test-retest reliability and practice effects for the Automated Neuropsychological Assessment Metrics General Neuropsychological Screening battery (ANAM GNS) in a sample of 94 community dwelling adults. ANAM GNS was administered and then repeated (alternate form) after 30 days. Test-retest reliability, practice effects, and the standard error of measurement were calculated. Using these estimates, reliable change indices were calculated to determine degree of performance change needed to exceed chance and measurement error (with 90% confidence interval). The test-retest reliability for the ANAM composite score was .91. Performance significantly improved upon retest, but the effect size was small consistent with minimal practice effects. The threshold indicating change beyond chance or measurement error with 90% certainty was .9 (z-score). Findings suggest that the ANAM GNS has excellent test-retest reliability upon retest at 30 days. Small practice effects can be expected. Change greater than .9 standard deviations in the ANAM composite score is likely to represent meaningful clinical change. This paper presents initial psychometric data from the ANAM GNS and supports its use as a reliable measure of cognition.

  1. The Placenta in Toxicology. Part IV: Battery of Toxicological Test Systems Based on Human Placenta

    Science.gov (United States)

    Göhner, Claudia; Svensson-Arvelund, Judit; Pfarrer, Christiane; Häger, Jan-Dirk; Faas, Marijke; Ernerudh, Jan; Cline, J. Mark; Dixon, Darlene; Buse, Eberhard; Markert, Udo R.

    2014-01-01

    This review summarizes the potential and also some limitations of using human placentas, or placental cells and structures for toxicology testing. The placenta contains a wide spectrum of cell types and tissues, such as trophoblast cells, immune cells, fibroblasts, stem cells, endothelial cells, vessels, glands, membranes, and many others. It may be expected that in many cases the relevance of results obtained from human placenta will be higher than those from animal models due to species specificity of metabolism and placental structure. For practical and economical reasons, we propose to apply a battery of sequential experiments for analysis of potential toxicants. This should start with using cell lines, followed by testing placenta tissue explants and isolated placenta cells, and finally by application of single and dual side ex vivo placenta perfusion. With each of these steps, the relative workload increases while the number of feasible repeats decreases. Simultaneously, the predictive power enhances by increasing similarity with in vivo human conditions. Toxic effects may be detected by performing proliferation, vitality and cell death assays, analysis of protein and hormone expression, immunohistochemistry or testing functionality of signaling pathways, gene expression, transport mechanisms, and so on. When toxic effects appear at any step, the subsequent assays may be cancelled. Such a system may be useful to reduce costs and increase specificity in testing questionable toxicants. Nonetheless, it requires further standardization and end point definitions for better comparability of results from different toxicants and to estimate the respective in vivo translatability and predictive value. PMID:23548605

  2. Long-range propagation effects observed during acoustic counter battery system tests

    Science.gov (United States)

    Velea, Doru; Cardinale, Michael; Torvik, Kevin; LaRow, Andy; Chang, Jay

    2006-05-01

    In March 2005, Planning Systems, Inc. (PSI), Advanced Acoustic Concepts (AAC) and the U.S. Army Research Development and Engineering Center (ARDEC) tested the PSI Acoustic Counter Battery System (ACBS) at the Yuma Proving Ground (YPG). ACBS was designed to acoustically detect and locate mortar fire, and to detect and locate heavy artillery fire out to ranges beyond 12 km. During analysis of the test data, we discovered that long-range sensors were receiving multiple pulses in doublets and triplets from a single shot. Additionally, we observed that the leading pulses were arriving earlier than anticipated by surface speed of sound calculations. The analysis team modeled the atmosphere recorded during the test and identified the possible causes of multiple arrivals by modeling the supersonic projectile trajectory and by using Green's Function Parabolic Equation numerical techniques to propagate recorded pulses from the source to receivers. The lessons learned will be applied to adjust the signal processing algorithms in the ACBS. This paper describes the test setup and reports the results of the analysis.

  3. [A study on the normal values of musical sounds in cochlear implants test battery].

    Science.gov (United States)

    Dong, Ruijuan; Wang, Shuo; Zhou, Yun; Qi, Beier; Chen, Xueqing; Liu, Bo

    2013-07-01

    To establish music reference values for normal-hearing (NH) person in China, in order to give convenience in clinical application. The NH participant group included 39 subjects, of which 21 females and 18 males. Musical Sounds in Cochlear Implants test battery was used to assess the music perception ability for normal-hearing participants. The median pitch difference NH participants could discriminate for string was 2.5 semitones and 0.5 for flute. The average scores of rhythm discrimination, melody discrimination, chord discrimination, instrument identification and instrument number detection test were 86.1% (SD = 11.2), 76.5% (SD = 11.1), 75.6% (SD = 11.4), 89.9% (SD = 13.0) and 74.1% (SD = 20.7), respectively. The MuSIC test could be a test for music perception ability for China users and in further study the material that more suited for our culture should be added into it.

  4. [The battery of tests for behavioral phenotyping of aging animals in the experiment].

    Science.gov (United States)

    Gorina, Ya V; Komleva, Yu K; Lopatina, O L; Volkova, V V; Chernykh, A I; Shabalova, A A; Semenchukov, A A; Olovyannikova, R Ya; Salmina, A B

    2017-01-01

    The purpose of the study was to develop a battery of tests to study social and cognitive impairments for behavioral phenotyping of aging experimental animals with physiological neurodegeneration. Object of the study were outbred CD1 mice in the following groups: 1st group - 12-month old male mice (physiological aging); 2nd group - 2-month old male mice (control group). Social recognition test, elevated plus maze test (EPM), open field test, light-dark box test, and Fear conditioning protocol were used to estimate the neurological status of experimental animals. We found that aging male mice in a contrast to young ones have demonstrated lower social interest to female mice in the social recognition task. EPM and light-dark box tests showed increased level of anxiety in the group of aged mice comparing to the control group. Fear conditioning protocol revealed impairment of associative learning and memory in the group of aged mice, particularly, fear memory consolidation was dramatically suppressed. Analysis of behavioral factors, social interactions and anxiety level in the experimental mice has confirmed age-related neurodegeneration in the 1st group. We found that the most informative approach to identifying neurological impairments in aging mice (social interaction deficit, limitation of interests, increased level of anxiety) should be based on the open field test light-dark box test, and Fear conditioning protocol. Such combination allows obtaining new data on behavioral alterations in the age-associated of neurodegeneration and to develop novel therapeutic strategies for the treatment of age-related brain pathology.

  5. Performance Testing of Lithium Li-ion Cells and Batteries in Support of JPL's 2003 Mars Exploration Rover Mission

    Science.gov (United States)

    Smart, Marshall C.; Ratnakumar, B. V.; Ewell, R. C.; Whitcanack, L. D.; Surampudi, S.; Puglia, F.; Gitzendanner, R.

    2007-01-01

    In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(super 0)C to +40(super 0)C), withstand long storage periods (e.g., including pre-launch and cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the inability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The primary focus of this paper is to communicate the latest results regarding Mars surface operation mission simulation testing, as well as, the corresponding performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by Yardney Technical Products, Inc.) have been demonstrated to far exceed the requirements defined by the mission, being able to support the operation of the rovers for over three years, and are projected to support an even further extended mission.

  6. Visual Working Memory and Perception Speed of 3- to 6-Year-Old Children Tested with a Matrix Film Battery Test

    Science.gov (United States)

    Pittorf, Martin L.; Lehmann, Wolfgang; Huckauf, Anke

    2014-01-01

    In this study the visual working memory (VWM) and perception speed of 60 children between the ages of three and six years were tested with an age-based, easy-to-handle Matrix Film Battery Test (reliability R?=?0.71). It was thereby affirmed that the VWM is age dependent (correlation coefficient r?=?0.66***) as expected. Furthermore, a significant…

  7. Design and testing of a virtual environment to train stroke patients with unilateral spatial neglect to cross a street safely.

    Science.gov (United States)

    Weiss, Patrice L Tamar; Naveh, Yuval; Katz, Noomi

    2003-01-01

    Virtual reality (VR) entails the use of advanced technologies, including computers and various multimedia peripherals, to produce a simulated (that is, virtual) environment that users perceive as comparable to real world objects and events. In recent years, virtual reality technologies have begun to be used as an assessment and treatment tool in occupational therapy, in part because of the ability to create environments that provide patients with opportunities to engage in meaningful, purposeful tasks that are related to real-life interests and activities. The objective of this study was to determine the suitability and feasibility of using a PC-based, non-immersive, VR system (that is, a system in which the user has a reduced sense of actual presence in and control over the simulated environment) for training individuals with unilateral spatial neglect to cross streets in a safe and vigilant manner. A virtual environment, consisting of a typical city street, was programmed using Superscape's 3D-Webmaster, a 3D web-authoring tool. Twelve subjects, aged 55 to 75 years, participated in the initial feasibility study and, to date, a further eight subjects have participated in the intervention study. Six of the initial subjects and all eight of the intervention subjects had sustained a right hemispheric stroke at least 6 weeks prior to the study. The remaining subjects were healthy age-matched adults who were independently mobile and had no difficulty in crossing streets. The results show that this virtual environment was suitable in both its cognitive and motor demands for the targeted population and indicate that the virtual reality training is likely to prove beneficial to people who have difficulty with crossing streets. The generalizability of these results, and recommendations regarding the use of virtual reality as an occupational therapy intervention, must be substantiated by further studies using a range of VR platforms with people with different cognitive and

  8. Physical fitness and future cardiovascular risk in argentine children and adolescents: an introduction to the ALPHA test battery.

    Science.gov (United States)

    Secchi, Jeremías David; García, Gastón César; España-Romero, Vanesa; Castro-Piñero, José

    2014-04-01

    A high level of physical fitness is associated with cardiovascular health in children and adolescents. At present, there is no systematic implementation of a test battery to assess physical fitness at schools in Argentina. The main objective of this study was to implement the ALPHA test battery to determine the physical fitness of a sample made up of Argentine children and adolescents and to establish the proportion of subjects whose aerobic capacity is indicative of future cardiovascular risk. A sample of 1867 participants (967 girls) aged 6 to 19.5 years old assessed using the ALPHA test battery. Four components of physical fitness were measured: 1) morphological component: height, body weight, and waist circumference; 2) musculoskeletal component: standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) cardiorespiratory component: course-navette 20 m, shuttle run test and estimation of maximal oxygen consumption. The 5th, 25th, 50th, 75th, and 95th percentiles were estimated for the main tests. The mean body mass index was 20.8 kg/m2, and 7.8% of participants were classified as obese. In ddition, male participants had a better performance in all physical fitness tests when compared to girls (pphysical fitness. Such differences increase with age. Approximately one every three participants had an aerobic capacity indicative of future cardiovascular risk.

  9. Risk factor of visuospatial neglect: a study of association between visuospatial neglect and anemia.

    Science.gov (United States)

    Kim, Ho Jeong; Yoon, Tae Sik; Han, Soo Jeong

    2013-10-01

    To investigate the correlation between visuospatial neglect and anemia in patients with right cerebral infarction, as well as to identify the risk factor of neglect and furnish preliminary data on rehabilitation management. The line bisection test and Albert test were conducted on subjects with right cerebral infarction in order to analyze neglect severity. Multiple linear regression analysis was conducted to investigate correlation between neglect severity and hemoglobin and hematocrit level. Logistic regression analysis was applied to identify the risk factor of neglect. Visuospatial neglect was observed in 33 subjects out of 124. Hemoglobin and hematocrit were not directly correlated with visuospatial neglect severity, whereas infarct size was directly correlated. Subjects with visuospatial neglect were characterized by a large infarct size, a low score in the Mini-Mental State Examination and long hospital stay. In this study, visuospatial neglect was found to be uncorrelated with anemia. It implies that emphasis should be placed on the early detection of anemia and neglect in patients with left hemiplegia, the formulation of respective therapeutic plans and improvement of prognosis. The study found that the possibility of a visuospatial neglect occurrence increases with infarct size. In this regard, it is required that visuospatial neglect was detected and treated in the earliest possible stage, notwithstanding the difficulty that lies in the precise measurement of the severity.

  10. Post-test analysis of lithium-ion battery materials at Argonne National Laboratory

    Science.gov (United States)

    Bareno, Javier; Dietz-Rago, Nancy; Bloom, Ira

    2014-03-01

    Electrochemical performance is often limited by surface and interfacial reactions at the electrodes. However, routine handling of samples can alter the very surfaces that are the object of study. Our approach combines standardized testing of batteries with sample harvesting under inert atmosphere conditions. Cells of different formats are disassembled inside an Argon glove box with controlled water and oxygen concentrations below 2 ppm. Cell components are characterized in situ, guaranteeing that observed changes in physicochemical state are due to electrochemical operation, rather than sample manipulation. We employ a complementary set of spectroscopic, microscopic, electrochemical and metallographic characterization to obtain a complete picture of cell degradation mechanisms. The resulting information about observed degradation mechanisms is provided to materials developers, both academic and industrial, to suggest new strategies and speed up the Research & Development cycle of Li-ion and related technologies. This talk will describe Argonne's post-test analysis laboratory, with an emphasis on capabilities and opportunities for collaboration. Cell disassembly, sample harvesting procedures and recent results will be discussed. This work was performed under the auspices of the U.S. Department of Energy, Office of Vehicle Technologies, Hybrid and Electric Systems, under Contract No. DE-AC02-06CH11357.

  11. Strain-specific battery of tests for domains of mania: effects of valproate, lithium and imipramine

    Directory of Open Access Journals (Sweden)

    Shlomit Flaisher-Grinberg

    2010-04-01

    Full Text Available The lack of efficient animal models for bipolar disorder (BPD, especially for the manic pole, is a major factor hindering the research of its pathophysiology and the development of improved drug treatments. The present study was designed to identify an appropriate mouse strain for modeling some behavioral domains of mania and to evaluate the effects of drugs using this strain. The study compared the behavior of four strains: Black Swiss, C57Bl/6, CBA/J and A/J mice in a battery of tests that included spontaneous activity; sweet solution preference; light/dark box; resident-intruder; forced-swim and amphetamine-induced hyperactivity. Based on the ‘manic-like’ behavior demonstrated by the Black Swiss strain, the study evaluated the effects of the mood stabilizers valproate and lithium and of the antidepressant imipramine in the same tests using this strain. Results indicated that lithium and valproate attenuate the ‘manic-like’ behavior of Black Swiss mice whereas imipramine had no effects. These findings suggest that Black Swiss mice might be a good choice for modeling several domains of mania and distinguishing the effects of drugs on these specific domains. However, the relevance of the behavioral phenotype of Black Swiss mice to the biology of BPD is unknown at this time and future studies will investigate molecular differences between Black Swiss mice and other strains and asess the interaction between strain and mood stabilizing treatment.

  12. Comparison of Physical Fitness Parameters with EUROFIT Test Battery of Male Adolescent Soccer Players and Sedentary Counterparts

    Directory of Open Access Journals (Sweden)

    Özgür ERİKOĞLU

    2015-09-01

    Full Text Available The aim of this study was to compare physical fitness parameters of male adolescent soccer players and sedentary counterparts. A total of 26 male adolescents participated in this study voluntarily: Active soccer players (n: 3, age x : 13,00 ± 0,00 and sedentary counterparts (n: 13, age x :12,92 ± 0,75. The EUROFIT test battery was used to determine physical fitness. The test battery includes body height and weight measurements, touching the discs, flamingo balan ce, throwing health ball, vertical jumping, sit and reach, sit - up for 30 s, 20 meter sprint run, and 20 meter shuttle run tests. Data were analyzed by Mann Whitney U test. Significance was defined as p.05. In conclusion, children who do sports are more successful on most of the fitness parameters than sedentary children.

  13. Verification test for an electric vehicle using capacitor-battery series connection for battery load levelling; Denchi no fuka heijunka no tame no kyapashita to denchi no chokuretsu setsuzoku hoshiki wo saiyoshita denki jidosha no jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    Miyaoka, K.; Takehara, J.; Kato, S. [Chugoku Electric Power Co. Inc., Hiroshima (Japan)

    1998-03-25

    For the prolongation of the distance that an electric vehicle (EV) can cover on a single charge and of the service life of the EV battery unit, a system is developed, in which the battery unit and the capacitor unit are connected in series for the levelling-off of battery peak loads, and the system is tested aboard a running real vehicle. Installed on the real vehicle is a battery unit that is a series connection of 20 12V-38Ah seal-type lead-acid batteries, each battery consisting of two cells connected in parallel. Driving the vehicle is a DC brushless motor capable of a maximum operation of 9000rpm. Also installed is a capacitor unit that is a parallel connection of 40 2.3V-1800F capacitors, each capacitor consisting of two capacitors connected in parallel. Findings are described below. In a 0-400m acceleration test, 22.5 seconds is recorded with the capacitor unit in operation, meaning an improvement of 0.7 seconds. The maximum speed remains unchanged at 110km/h, which agrees with the pre-calculated value. Although the battery peak load reduction rate in a 15-mode drive pattern marks 23%, the distances covered on a single charge in this drive pattern turn out to be almost the same whether the capacitor unit is in operation or not. 3 refs., 15 figs., 3 tabs.

  14. Acquisition of Co metal from spent lithium-ion battery using emulsion liquid membrane technology and emulsion stability test

    Science.gov (United States)

    Yuliusman; Wulandari, P. T.; Amiliana, R. A.; Huda, M.; Kusumadewi, F. A.

    2018-03-01

    Lithium-ion batteries are the most common type to be used as energy source in mobile phone. The amount of lithium-ion battery wastes is approximated by 200 – 500 ton/year. In one lithium-ion battery, there are 5 – 20% of cobalt metal, depend on the manufacturer. One of the way to recover a valuable metal from waste is leaching process then continued with extraction, which is the aim of this study. Spent lithium-ion batteries will be characterized with EDX and AAS, the result will show the amount of cobalt metal with form of LiCoO2 in the cathode. Hydrochloric acid concentration used is 4 M, temperature 80°C, and reaction time 1 hour. This study will discuss the emulsion stability test on emulsion liquid membrane. The purpose of emulsion stability test in this study was to determine optimum concentration of surfactant and extractant to produce a stable emulsion. Surfactant and extractant used were SPAN 80 and Cyanex 272 respectively with both concentrations varied. Membrane and feed phase ratios used in this experiment was 1 : 2. The optimum results of this study were SPAN 80 concentrations of 10% w/v and Cyanex 272 0.7 M.

  15. Effects of Pro-Cholinergic Treatment in Patients Suffering from Spatial Neglect

    Science.gov (United States)

    Lucas, N.; Saj, A.; Schwartz, S.; Ptak, R.; Thomas, C.; Conne, P.; Leroy, R.; Pavin, S.; Diserens, K.; Vuilleumier, Patrik

    2013-01-01

    Spatial neglect is a neurological condition characterized by a breakdown of spatial cognition contralateral to hemispheric damage. Deficits in spatial attention toward the contralesional side are considered to be central to this syndrome. Brain lesions typically involve right fronto-parietal cortices mediating attentional functions and subcortical connections in underlying white matter. Convergent findings from neuroimaging and behavioral studies in both animals and humans suggest that the cholinergic system might also be critically implicated in selective attention by modulating cortical function via widespread projections from the basal forebrain. Here we asked whether deficits in spatial attention associated with neglect could partly result from a cholinergic deafferentation of cortical areas subserving attentional functions, and whether such disturbances could be alleviated by pro-cholinergic therapy. We examined the effect of a single-dose transdermal nicotine treatment on spatial neglect in 10 stroke patients in a double-blind placebo-controlled protocol, using a standardized battery of neglect tests. Nicotine-induced systematic improvement on cancellation tasks and facilitated orienting to single visual targets, but had no significant effect on other tests. These results support a global effect of nicotine on attention and arousal, but no effect on other spatial mechanisms impaired in neglect. PMID:24062674

  16. Modafinil and cognitive enhancement in schizophrenia and healthy volunteers: the effects of test battery in a randomised controlled trial.

    Science.gov (United States)

    Lees, J; Michalopoulou, P G; Lewis, S W; Preston, S; Bamford, C; Collier, T; Kalpakidou, A; Wykes, T; Emsley, R; Pandina, G; Kapur, S; Drake, R J

    2017-10-01

    Cognitive deficits in schizophrenia have major functional impacts. Modafinil is a cognitive enhancer whose effect in healthy volunteers is well-described, but whose effects on the cognitive deficits of schizophrenia appear to be inconsistent. Two possible reasons for this are that cognitive test batteries vary in their sensitivity, or that the phase of illness may be important, with patients early in their illness responding better. A double-blind, randomised, placebo-controlled single-dose crossover study of modafinil 200 mg examined this with two cognitive batteries [MATRICS Consensus Cognitive Battery (MCCB) and Cambridge Neuropsychological Test Automated Battery (CANTAB)] in 46 participants with under 3 years' duration of DSM-IV schizophrenia, on stable antipsychotic medication. In parallel, the same design was used in 28 age-, sex-, and education-matched healthy volunteers. Uncorrected p values were calculated using mixed effects models. In patients, modafinil significantly improved CANTAB Paired Associate Learning, non-significantly improved efficiency and significantly slowed performance of the CANTAB Stockings of Cambridge spatial planning task. There was no significant effect on any MCCB domain. In healthy volunteers, modafinil significantly increased CANTAB Rapid Visual Processing, Intra-Extra Dimensional Set Shifting and verbal recall accuracy, and MCCB social cognition performance. The only significant differences between groups were in MCCB visual learning. As in earlier chronic schizophrenia studies, modafinil failed to produce changes in cognition in early psychosis as measured by MCCB. CANTAB proved more sensitive to the effects of modafinil in participants with early schizophrenia and in healthy volunteers. This confirms the importance of selecting the appropriate test battery in treatment studies of cognition in schizophrenia.

  17. Qualification and Life Testing of Li-Ion Ves16 Batteries

    Directory of Open Access Journals (Sweden)

    Remy Stéphane

    2017-01-01

    Up to the present time, Saft batteries have been mainly utilizing for space applications high capacity cells, like the 45 Ah VES180 and the 35 Ah VES140 cells, targeting predominantly space missions in Geostationary Earth Orbit (GEO. However following the qualification and commercialization of the Saft 4.5 Ah VES16 cell in October 2011 [1] & [2], Saft has been developing and qualifying in the frame of this ESA GSTP 5.2 contract, VES 16 batteries for space missions, targeting both GEO and Low Earth Orbit (LEO satellite missions. The electrochemistry of the VES16 cells used for the battery modules under the ESA qualification program is not novel. For VES16 cells, the Saft knowhow from large capacity space cells used for space applications, since SMART 1 mission in 2003, has been tailored for a cell with smaller capacity in order to facilitate the modular philosophy that has been deployed in this battery range.

  18. Functional Observational Battery Testing for Nervous System Effects of Drugs and Other Chemicals

    Science.gov (United States)

    Screening for behavioral toxicity, or neurotoxicity, has become standard practice in preclinical safety pharmacology and toxicology. Behavior represents the integrated sum of activities mediated by the nervous system. Current screening batteries, such as the functional observat...

  19. Analisis Teoritis dan Empiris Uji Craps dari Diehard Battery of Randomness Test untuk Pengujian Pembangkit Bilangan Acaksemu

    Directory of Open Access Journals (Sweden)

    Sari Agustini Hafman

    2013-05-01

    Full Text Available According to Kerchoffs (1883, the security system should only rely on cryptographic keys which is used in that system. Generally, the key sequences are generated by a Pseudo Random Number Generator (PRNG or Random Number Generator (RNG. There are three types of randomness sequences that generated by the RNG and PRNG i.e. pseudorandom sequence, cryptographically secure pseudorandom sequences, and real random sequences. Several statistical tests, including diehard battery of tests of randomness, is used to check the type of randomness sequences that generated by PRNG or RNG. Due to its purpose, the principle on taking the testing parameters and the test statistic are associated with the validity of the conclusion produced by a statistical test, then the theoretical analysis is performed by applying a variety of statistical theory to evaluate craps test, one of the test included in the diehard battery of randomness tests. Craps test, inspired by craps game, aims to examine whether a PRNG produces an independent and identically distributed (iid pseudorandom sequences. To demonstrate the process to produce a test statistics equation and to show how craps games applied on that test, will be carried out theoretical analysis by applying a variety of statistical theory. Furthermore, empirical observations will be done by applying craps test on a PRNG in order to check the test effectiveness in detecting the distribution and independency of sequences which produced by PRNG

  20. Old world monkeys compare to apes in the primate cognition test battery.

    Directory of Open Access Journals (Sweden)

    Vanessa Schmitt

    Full Text Available Understanding the evolution of intelligence rests on comparative analyses of brain sizes as well as the assessment of cognitive skills of different species in relation to potential selective pressures such as environmental conditions and social organization. Because of the strong interest in human cognition, much previous work has focused on the comparison of the cognitive skills of human toddlers to those of our closest living relatives, i.e. apes. Such analyses revealed that apes and children have relatively similar competencies in the physical domain, while human children excel in the socio-cognitive domain; in particular in terms of attention sharing, cooperation, and mental state attribution. To develop a full understanding of the evolutionary dynamics of primate intelligence, however, comparative data for monkeys are needed. We tested 18 Old World monkeys (long-tailed macaques and olive baboons in the so-called Primate Cognition Test Battery (PCTB (Herrmann et al. 2007, Science. Surprisingly, our tests revealed largely comparable results between Old World monkeys and the Great apes. Single comparisons showed that chimpanzees performed only better than the macaques in experiments on spatial understanding and tool use, but in none of the socio-cognitive tasks. These results question the clear-cut relationship between cognitive performance and brain size and--prima facie--support the view of an accelerated evolution of social intelligence in humans. One limitation, however, is that the initial experiments were devised to tap into human specific skills in the first place, thus potentially underestimating both true nonhuman primate competencies as well as species differences.

  1. Custom-Service Representative (Light, Heat, & Power; Tel. & Tel.; Waterworks) 239.367-010. Development of USES Specific Aptitude Test Battery.

    Science.gov (United States)

    Employment and Training Administration (DOL), Washington, DC.

    The United States Employment Service (USES) Specific Aptitude Test Battery (SATB) for Customer-Service Representative is evaluated from three points of view: (1) technical adequacy of the research; (2) fairness to minorities; and (3) usefulness of the battery to Employment Service staff and employers in selecting individuals for training in…

  2. Using the Cognitive Abilities Test (CogAT) 7 Nonverbal Battery to Identify the Gifted/Talented: An Investigation of Demographic Effects and Norming Plans

    Science.gov (United States)

    Carman, Carol A.; Walther, Christine A. P.; Bartsch, Robert A.

    2018-01-01

    The nonverbal battery of the Cognitive Abilities Test (CogAT) is one of the two most common nonverbal measures used in gifted identification, yet the relationships between demographic variables and CogAT7 performance has not yet been fully examined. Additionally, the effect of using the CogAT7 nonverbal battery on the identification of diverse…

  3. A Comprehensive Behavioral Test Battery to Assess Learning and Memory in 129S6/Tg2576 Mice

    Science.gov (United States)

    Wolf, Andrea; Bauer, Björn; Abner, Erin L.; Ashkenazy-Frolinger, Tal; Hartz, Anika M. S.

    2016-01-01

    Transgenic Tg2576 mice overexpressing human amyloid precursor protein (hAPP) are a widely used Alzheimer’s disease (AD) mouse model to evaluate treatment effects on amyloid beta (Aβ) pathology and cognition. Tg2576 mice on a B6;SJL background strain carry a recessive rd1 mutation that leads to early retinal degeneration and visual impairment in homozygous carriers. This can impair performance in behavioral tests that rely on visual cues, and thus, affect study results. Therefore, B6;SJL/Tg2576 mice were systematically backcrossed with 129S6/SvEvTac mice resulting in 129S6/Tg2576 mice that lack the rd1 mutation. 129S6/Tg2576 mice do not develop retinal degeneration but still show Aβ accumulation in the brain that is comparable to the original B6;SJL/Tg2576 mouse. However, comprehensive studies on cognitive decline in 129S6/Tg2576 mice are limited. In this study, we used two dementia mouse models on a 129S6 background—scopolamine-treated 129S6/SvEvTac mice (3–5 month-old) and transgenic 129S6/Tg2576 mice (11–13 month-old)–to establish a behavioral test battery for assessing learning and memory. The test battery consisted of five tests to evaluate different aspects of cognitive impairment: a Y-Maze forced alternation task, a novel object recognition test, the Morris water maze, the radial arm water maze, and a Y-maze spontaneous alternation task. We first established this behavioral test battery with the scopolamine-induced dementia model using 129S6/SvEvTac mice and then evaluated 129S6/Tg2576 mice using the same testing protocol. Both models showed distinctive patterns of cognitive impairment. Together, the non-invasive behavioral test battery presented here allows detecting cognitive impairment in scopolamine-treated 129S6/SvEvTac mice and in transgenic 129S6/Tg2576 mice. Due to the modular nature of this test battery, more behavioral tests, e.g. invasive assays to gain additional cognitive information, can easily be added. PMID:26808326

  4. A Comprehensive Behavioral Test Battery to Assess Learning and Memory in 129S6/Tg2576 Mice.

    Directory of Open Access Journals (Sweden)

    Andrea Wolf

    Full Text Available Transgenic Tg2576 mice overexpressing human amyloid precursor protein (hAPP are a widely used Alzheimer's disease (AD mouse model to evaluate treatment effects on amyloid beta (Aβ pathology and cognition. Tg2576 mice on a B6;SJL background strain carry a recessive rd1 mutation that leads to early retinal degeneration and visual impairment in homozygous carriers. This can impair performance in behavioral tests that rely on visual cues, and thus, affect study results. Therefore, B6;SJL/Tg2576 mice were systematically backcrossed with 129S6/SvEvTac mice resulting in 129S6/Tg2576 mice that lack the rd1 mutation. 129S6/Tg2576 mice do not develop retinal degeneration but still show Aβ accumulation in the brain that is comparable to the original B6;SJL/Tg2576 mouse. However, comprehensive studies on cognitive decline in 129S6/Tg2576 mice are limited. In this study, we used two dementia mouse models on a 129S6 background--scopolamine-treated 129S6/SvEvTac mice (3-5 month-old and transgenic 129S6/Tg2576 mice (11-13 month-old-to establish a behavioral test battery for assessing learning and memory. The test battery consisted of five tests to evaluate different aspects of cognitive impairment: a Y-Maze forced alternation task, a novel object recognition test, the Morris water maze, the radial arm water maze, and a Y-maze spontaneous alternation task. We first established this behavioral test battery with the scopolamine-induced dementia model using 129S6/SvEvTac mice and then evaluated 129S6/Tg2576 mice using the same testing protocol. Both models showed distinctive patterns of cognitive impairment. Together, the non-invasive behavioral test battery presented here allows detecting cognitive impairment in scopolamine-treated 129S6/SvEvTac mice and in transgenic 129S6/Tg2576 mice. Due to the modular nature of this test battery, more behavioral tests, e.g. invasive assays to gain additional cognitive information, can easily be added.

  5. The concurrent validity of the technical test battery as an indicator of work performance in a telecommunications company

    Directory of Open Access Journals (Sweden)

    Marelize Barnard

    2005-10-01

    Full Text Available The purpose of this study was to assess the concurrent validity of the Technical Test Battery (TTB in a South African telecommunications institution. The Technical Test Battery (TTB was administered to a sample of 107 technical officers. Their test scores were compared to the scores obtained from a job performance rating scale specifically designed for this position on the basis of a thorough job analysis. The TTB demonstrated high concurrent validity as an indicator of work performance for technical posts in the telecommunications environment. These results suggest that the TTB may have a high predictive validity for performance in technical positions. The findings and implications of the study are discussed. Opsomming Die doel van hierdie studie was om die samevallende geldigheid van die “Technical Test Battery (TTB�? in ’n Suid-Afrikaanse telekommunikasie instansie te bepaal. Die TTB is op ’n steekproef van 107 tegniese personeel toegepas. Die toetstellings is in verband gebring met die tellings van ’n werksprestasiemaatstaf wat spesifiek vir die pos ontwikkel is op grond van ’n deeglike posanalise. Daar is bevind dat die TTB ’n hoë samevallende geldigheid as aanduider van werksprestasie vir tegniese poste in the telekommunikasiebedryf toon. Dié resultate dui op ’n sterk moontlikheid dat die TTB ’n goeie voorspeller van werksprestasie vir tegniese beroepe kan wees. Die bevindinge en implikasies van die studie word bespreek.

  6. The challenge of producing skin test antigens with minimal resources suitable for human application against a neglected tropical disease; leprosy.

    Directory of Open Access Journals (Sweden)

    Becky L Rivoire

    Full Text Available True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan and MLCwA (M. leprae cell wall antigens. In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.

  7. Dental neglect among children in Chennai.

    Science.gov (United States)

    Gurunathan, Deepa; Shanmugaavel, Arunachalam Karthikeyan

    2016-01-01

    Child dental neglect is the failure of a parent or guardian to meet the child's basic oral health needs such that the child enjoys adequate function and freedom from pain and infection, where reasonable resources are available to family or caregiver. The aim of the study is to evaluate the phenomenon of dental neglect among children in Chennai and to associate dental neglect with oral health status of children aged 3-12 years. This is a cross-sectional study involving 478 pairs of parents and children. Dental neglect scale and a questionnaire were used to assess the dental neglect score among parents of the children involved in the study. Oral health status of children was clinically assessed using oral hygiene index, decayed, extracted, filled teeth (def(t)), pulp, ulcers, fistula, abscess (pufa), decayed, missing, filled teeth (DMFT), PUFA as per the World Health Organization criteria and pufa/PUFA index. Student's t-test and one-way ANOVA were used appropriately for statistical analysis using SPSS software version 20.0. A significant higher dental neglect score was reported among the parents who reside in the suburban location (P 3 years (P = 0.001). A significant higher DMFT (P = 0.003), deft (P = 0 neglect group. Child dental neglect is seen among the parents whose educational qualification was secondary, who reside in the suburban location, and who have not utilized the dental services for more than 3 years in Chennai. This dental neglect results in poorer oral health of children.

  8. Performance and cycle life test results of a PEVE first-generation prismatic nickel/metal-hydride battery pack

    Science.gov (United States)

    Potter, B. G.; Duong, T. Q.; Bloom, I.

    A first-generation, prismatic, nickel/metal-hydride battery pack from Panasonic EV Energy Company Ltd. (PEVE) was characterized following the standard PNGV test procedures and then cycle life tested at 25 °C. The pack met, or exceeded, PNGV power and energy goals at the beginning of life. After more than 500,000 cycles, the data for capacity and discharge pulse power capability showed no measurable fade; similarly, discharge pulse resistance at 60% DOD also showed no measurable change. After the same pack was tested with two size factors, it still met or exceeded the PNGV goals.

  9. Performance Testing of Yardney Li-Ion Cells and Batteries in Support of JPL's 2009 Mars Science Laboratory Mission

    Science.gov (United States)

    Smart, M.C.; Ratnakumar, B.V.; Whitcanack, L. D.; Dewell, E. A.; Jones, L. E.; Salvo, C. G.; Puglia, F. J.; Cohen, S.; Gitzendanner, R.

    2008-01-01

    In 2009, JPL is planning to launch an unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than three years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar lithium-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. Although comparable in many facets, such as being required to operate over a wide temperature range (-20 to 40 C), the MSL mission has more demanding performance requirements compared to the MER mission, including much longer mission duration (approx. 687 sols vs. 90 sols), higher power capability, and the need to withstand higher temperature excursions. In addition, due to the larger rover size, the MSL mission necessitates the use of a much larger battery to meet the energy, life, and power requirements. In order to determine the viability of meeting these requirements, a number of performance verification tests were performed on 10 Ah Yardney lithium-ion cells (MER design) under MSL-relevant conditions, including mission surface operation simulation testing. In addition, the performance of on-going ground life testing of 10 Ah MER cells and 8-cell batteries will be discussed in the context of capacity loss and impedance growth predictions.

  10. Psychometric properties and convergent and predictive validity of an executive function test battery for two-year-olds

    Directory of Open Access Journals (Sweden)

    Hanna eMulder

    2014-07-01

    Full Text Available Executive function (EF is an important predictor of numerous developmental outcomes, such as academic achievement and behavioral adjustment. Although a plethora of measurement instruments exists to assess executive function in children, only few of these are suitable for toddlers, and even fewer have undergone psychometric evaluation. The present study evaluates the psychometric properties and validity of an assessment battery for measuring EF in two-year-olds. A sample of 2437 children were administered the assessment battery at a mean age of 2;4 years (SD = 0;3 years in a large-scale field study. Measures of both hot EF (snack and gift delay tasks and cool EF (six boxes, memory for location, and visual search task were included. Confirmatory Factor Analyses showed that a two-factor hot and cool EF model fitted the data better than a one-factor model. Measurement invariance was supported across groups differing in age, gender, socioeconomic status (SES, home language, and test setting. Criterion and convergent validity were evaluated by examining relationships between EF and age, gender, SES, home language, and parent and teacher reports of children’s attention and inhibitory control. Predictive validity of the test battery was investigated by regressing children’s pre-academic skills and behavioral problems at age three on the latent hot and cool EF factors at age two years. The test battery showed satisfactory psychometric quality and criterion, convergent, and predictive validity. Whereas cool EF predicted both pre-academic skills and behavior problems one year later, hot EF predicted behavior problems only. These results show that EF can be assessed with psychometrically sound instruments in children as young as two years, and that EF tasks can be reliably applied in large scale field research. The current instruments offer new opportunities for investigating EF in early childhood, and for evaluating interventions targeted at improving

  11. The Effect of Syntax on Reading in Neglect Dyslexia

    Science.gov (United States)

    Friedmann, Naama; Tzailer-Gross, Lital; Gvion, Aviah

    2011-01-01

    Individuals with text-based neglect dyslexia omit words on the neglected side of the sentence or text, usually on the left side. This study tested whether the syntactic structure of the target sentence affects reading in this type of neglect dyslexia. Because Hebrew is read from right to left, it enables testing whether the beginning of the…

  12. The psychobiology of neglect.

    Science.gov (United States)

    De Bellis, Michael D

    2005-05-01

    Child neglect, the most prevalent form of child maltreatment, is associated with adverse psychological and educational outcomes. It is hypothesized that these outcomes may be caused by adverse brain development. However, there are very few published cross-sectional studies and no prospective studies that examine the neurodevelopmental consequences of neglect. In this article, the author comprehensively outlines the issues involved in the psychobiological research of child neglect. Pre-clinical and clinical studies will be reviewed. Throughout the article, suggestions for future research opportunities and novel ways to address methodological difficulties inherent in this field of study are offered. The results of recent neuroimaging studies of maltreated children may provide a basis for understanding the early effects of neglect on childhood brain development. The author is comprehensively examining these issues as part of the Federal Child Neglect Consortium.

  13. The Utility of the Air Traffic Selection and Training Test Battery in Hiring Graduates of an Air Traffic-Collegiate Training Initiative Program

    Science.gov (United States)

    2013-06-01

    computerized pre- employment test battery designed to assess a candidate’s aptitude for performing the duties of an ATCS. Applicants must score as...pass AT-SAT. AT-SAT is a computerized pre-employment test battery designed to assess a candidate’s aptitude for performing the duties of an ATCS...been enrolled in a CTI program. Federal Personnel/ Payroll System (FPPS) FPPS is the official system of records for FAA personnel. All ATCS applicants

  14. Nonleaking battery terminals.

    Science.gov (United States)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45% KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a KOH electrolyte in a plastic case are considered.

  15. Executive functioning in three groups of pupils in D-KEFS: Selected issues in adapting the test battery for Slovakia

    Directory of Open Access Journals (Sweden)

    Ferjenčík Ján

    2015-06-01

    Full Text Available The paper reports on the adaptation of a D-KEFS test battery for Slovakia. Drawing on concrete examples, it describes and illustrates the key issues relating to the transfer of test items from one socio-cultural environment to another. The standardisation sample of the population of Slovak pupils in the fourth year of primary school included 250 children with an average age of 9.7 years. The two comparative samples of the same age range were analysed at the same time. They included pupils from classes for gifted children (n = 55 and Roma children from socially disadvantaging environments (n = 50.

  16. Sociolinguistic reflection on neuropsychological assessment: an insight into selected culturally adapted battery of Lebanese Arabic cognitive testing.

    Science.gov (United States)

    Abou-Mrad, Fadi; Tarabey, Lubna; Zamrini, Edward; Pasquier, Florence; Chelune, Gordon; Fadel, Patricia; Hayek, Maryse

    2015-10-01

    Neuropsychological tests (NPTs) are highly dependent on education, culture differences as well as age and sex. It is therefore essential to take these factors into consideration when translating NPTs to be used in screening for cognitive impairment. Translations into Arabic must respect the principles of linguistic relativity and cultural specificity of the population under study. The objective is to assess feasibility and outcome of translating neuropsychological tests to Arabic. A team of Lebanese professionals selected a battery of screening NPTs. These tests were translated into Arabic and independently back translated by a team of sociolinguists and cultural specialists. The translations were adapted to suit the Lebanese culture. The final NPT translated versions were reached by consensus of an expert panel and tested on a group of independently living community-dwelling elderly. Translated items had to be modified when: (1) terms could not be translated using one word as required by the test; (2) Concepts were foreign to the culture; (3) Translated words carried multiple meanings; (4) Words were rarely used in Lebanon; (5) Sentences did not have an equivalent; and (6) Words had letters pronounced differently by subgroups in Lebanon. Despite all measures to maintain cultural sensitivity in translations, non-linguistic challenges remained. A battery of cognitive screening tests were translated into Arabic and adapted for the Lebanese population. These adaptations allow for a better assessment of cognitive abilities since they reflect the thought patterns of the population. The challenge is to establish local normative data.

  17. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  18. Elder Abuse and Neglect

    Directory of Open Access Journals (Sweden)

    Muge Gulen

    2013-06-01

    Full Text Available Abuse and neglect are preventable societal problems that influence elderly individuals physically, spiritually and socially. Elder abuse is neglected for many years and is a growing problem all over the world. The aim of this article is to review the evaluation of elderly individuals who are exposed to abuse and neglect with systematic detailed history and physical examination and to describe individual, familial, and social measures that should be taken to prevent these abuses. [Archives Medical Review Journal 2013; 22(3.000: 393-407

  19. Neglected tropical diseases, neglected data sources, and neglected issues.

    Directory of Open Access Journals (Sweden)

    Burton H Singer

    Full Text Available BACKGROUND: Lymphatic filariasis (LF is a so-called neglected tropical disease, currently overshadowed by higher-profile efforts to address malaria, tuberculosis, and HIV/AIDS. Despite recent successes in arresting transmission, some 40 million people who already have the disease have been largely neglected. This study aims to increase understanding of how this vulnerable, neglected group can be helped. METHODS: We used purposive sampling to select 60 men and women with filarial lymphoedema (45 with filarial elephantiasis and 15 men with filarial hydrocoele from the south of Sri Lanka in 2004-2005. Participants were selected to give a balance of men and women and poor and nonpoor, and a range of stages of the disease. Participants' experiences and the consequences of their disease for the household were explored with in-depth qualitative, semistructured interviews. FINDINGS: LF was extremely debilitating to participants over long periods of time. The stigma attached to the condition caused social isolation and emotional distress, and delayed diagnosis and treatment, resulting in undue advancement of the disease. Free treatment services at government clinics were avoided because the participants' condition would be identifiable in public. Loss of income due to the condition was reported by all households in the sample, not just the poorest. Households that were already on low incomes were pushed into near destitution, from which it was almost impossible to escape. Affected members of low-income households also had less opportunity to obtain appropriate treatment from distant clinics, and had living and working conditions that made hygiene and compliance difficult. SIGNIFICANCE: This highly vulnerable category of patients has low visibility, thus becoming marginalized and forgotten. With an estimated 300,000 total cases of elephantiasis and/or oedema in Sri Lanka, and around 300,000 men with filarial hydrocoele, the affected households will need

  20. Electric and hybrid vehicles charge efficiency tests of ESB EV-106 lead acid batteries

    Science.gov (United States)

    Rowlette, J. J.

    1981-01-01

    Charge efficiencies were determined by measurements made under widely differing conditions of temperature, charge procedure, and battery age. The measurements were used to optimize charge procedures and to evaluate the concept of a modified, coulometric state of charge indicator. Charge efficiency determinations were made by measuring gassing rates and oxygen fractions. A novel, positive displacement gas flow meter which proved to be both simple and highly accurate is described and illustrated.

  1. A new test battery to assess aphasic disturbances and associated cognitive dysfunctions -- German normative data on the aphasia check list.

    Science.gov (United States)

    Kalbe, Elke; Reinhold, Nadine; Brand, Matthias; Markowitsch, Hans J; Kessler, Josef

    2005-10-01

    Aphasia, defined as an acquired impairment of linguistic abilities, can be accompanied by a diversity of neuropsychological dysfunction. Accordingly, the necessity to include cognitive testing in the diagnosis of aphasia is increasingly recognized. Here we present the Aphasia Check List (ACL), a new test battery for the assessment of aphasic and associated cognitive disorders. The language part of the battery provides a differentiated profile of important linguistic abilities. In addition, the ACL includes nonverbal screening tests for three neuropsychological domains: memory, attention, and reasoning. Dysfunctions in these domains have been observed in aphasic patients and can have an impact on language function. The ACL is applicable to patients with language disturbances of different etiologies, different stages of disease, and to patients with mild to severe aphasia. As the entire test duration is only about 30 minutes, the ACL is also economically valuable. It thus presents an adequate starting point in aphasia diagnosis for a wide range of patients. Here we describe the construction of the ACL, and the normative study of its original German version with 154 aphasic patients and 106 healthy comparison subjects. The ACL cognition part revealed additional neuropsychological dysfunction in the aphasia group. We present the patterns of these dysfunctions and their correlations with language deficits.

  2. A Novel Battery of Graded Word and Non-Word Reading Tests to Identify Sub-Lexical Dyslexia in Kannada

    Directory of Open Access Journals (Sweden)

    Suresh Kiran

    2017-10-01

    Full Text Available Background: Sub-lexical dyslexia is characterized by difficulty in reading non-words relative to true words. Identification of this impairment requires tests assessing word and non-word reading performances. No such tests are available in Kannada, a South-Indian language. Objectives: a to develop and validate: Graded word and Graded non-word reading tests in Kannada b to standardize the tests by administering on 100 children each from Grades III to VII and to establish grade-wise criteria to identify sub-lexical dyslexia. Methods: The Graded Word Reading Test was developed separately for Grades III-VII by compiling 30 words each from Kannada textbook of the specific grade. The Graded Non-word Reading Test was developed by creating 70 randomized non-words. It was then given to 10 Kannada teachers to opine on the pronounceability and suitability of items for target Grades. The test battery was later administered on 25 children with good oral reading skills and subsequently standardized on a cross-section of 500 children from four Kannada-medium schools. This data was used to establish Grade-specific criteria for reading words and non-words in Kannada. Results: The Graded-word and non-word reading test demonstrated good content and face validity. A total of 44 (8.8% children were identified to have sub-lexical dyslexia across Grades. Conclusion: This novel test battery is first of its kind which also ‘quantifies’ the ‘relative performances’ on word and non-word reading to identify sub-lexical dyslexia in Kannada from Grades III to VII.

  3. Tocopherol in Elder Self-Neglect

    Science.gov (United States)

    Aung, K.; Burnett, J.; Dyer, C.; Smith, S. M.

    2009-01-01

    Although elder self-neglect is the most common form of elder mistreatment, its pathophysiology is not well understood. Alpha-tocopherol is a lipid soluble antioxidant required for the preservation of cell membranes. Since the association between tocopherol and cognitive impairment in older adults has been described, we explored the possibility of its role in elder self-neglect. OBJECTIVE: (1) To determine whether serum tocopherol levels are associated with elder self-neglect, and (2) to assess the association of serum tocopherol levels and cognitive function in elder self-neglect. METHODS: Serum tocopherol levels were measured in a cohort of 67 self-neglecting elders and 67 matched controls, recruited for the Consortium for Research in Elder Self-neglect of Texas. Pearson s correlation tests were performed to assess bivariate associations between serum tocopherol levels and cognitive function. RESULTS: Mean serum alpha-tocopherol levels were 10.8 +/- 4.7 ug/mL in self-neglect group and 13.0 +/- 4.9 ug/mL in control group (p = 0.006, unpaired student s t-test). None of the participants from either group had alpha-tocopherol level lower than the reference range. Mean serum gamma-tocopherol levels were 2.0 +/- 1.0 ug/mL in self-neglect group and 2.0 +/- 1.1 in control group (p=0.83). Proportion of the elders with gamma-tocopherol level lower than the reference range were 4.5% (3/66) in self-neglect group and 10.4% (7/67) in control group (p=0.32, Fisher s Exact Test). Among the self-neglecting elders, no association was found between serum alpha-tocopherol levels and the Mini-Mental State Examination (MMSE) or the Wolf-Klein Clock Drawing Test (CDT) scores (r =-0.42, p=0.75 for MMSE; r=0.08, p=0.54 for CDT). No association was found between serum gamma-tocopherol levels and the MMSE or the CDT (r=-0.12, p=0.35 for MMSE; r=0.05, p=0.68 for CDT). CONCLUSION: In our sample, neither alpha-tocopherol nor gamma-tocopherol appears to have a role in pathophysiology of elder

  4. Asparagus Sorter (agric.; can. & preserv.; whole tr.) 529.687 (8-04.10)--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  5. Fourdrinier-Machine Tender (paper & pulp, wallboard) 539.782; Back Tender, Paper Machine (paper & pulp) 534.782--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  6. Carpet Layer (ret. tr.) 7-59.220; Linoleum Layer (const.; ret. tr.) 5-32.732--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  7. Multi-Moulding Unit Operator (dental equip.) 712.884; Heater Operator (dental equip.) 712.884--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  8. Routeman, Bakery Products (ret. tr.; whole tr.) 1-80.06--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  9. Die-Casting-Machine Operator (nonfer. metal alloys & prod.) II 6-82.916--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  10. Battery Test Manual For 12 Volt Start/Stop Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Belt, Jeffrey R. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    This manual was prepared by and for the United Stated Advanced Battery Consortium (USABC) Electrochemical Energy Storage Team. It is based on the targets established for 12 Volt Start/Stop energy storage development and is similar (with some important changes) to an earlier manual for the former FreedomCAR program. The specific procedures were developed primarily to characterize the performance of energy storage devices relative to the USABC requirements. However, it is anticipated that these procedures will have some utility for characterizing 12 Volt Start/Stop hybrid energy storage device behavior in general.

  11. Design of a new lithium ion battery test cell for in-situ neutron diffraction measurements

    Science.gov (United States)

    Roberts, Matthew; Biendicho, Jordi Jacas; Hull, Stephen; Beran, Premysl; Gustafsson, Torbjörn; Svensson, Gunnar; Edström, Kristina

    2013-03-01

    This paper introduces a new cell design for the construction of lithium ion batteries with conventional electrochemical performance whilst allowing in situ neutron diffraction measurement. A cell comprising of a wound cathode, electrolyte and anode stack has been prepared. The conventional hydrogen-containing components of the cell have been replaced by hydrogen-free equivalents. The electrodes are fabricated using a PTFE binder, the electrolyte consists of deuterated solvents which are supported in a quartz glass fibre separator. Typical battery performance is reported using the hydrogen-free components with a specific capacity of 140 mA h g-1 being observed for LiFePO4 at a rate of 0.2 C. Neutron diffraction patterns of full cells were recorded with phase change reactions monitored. When aluminium packaging was used a better signal to noise ratio was obtained. The obtained atomic positions and lattice parameters for all cells investigated were found to be consistent with parameters refined from the diffraction pattern of a powder of the pure electrode material. This paper highlights the pertinent points in designing cells for these measurements and addresses some of the problems.

  12. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    DEFF Research Database (Denmark)

    Bousquet, P-J; Burbach, G; Heinzerling, L M

    2009-01-01

    or Alternaria]). According to country, up to 13 allergens were needed to identify all sensitized subjects. Conclusion: Eight to ten allergens allowed the identification of the majority of sensitized subjects. For clinical care of individual patients, the whole battery of 18 allergens is needed to appropriately...... the allergens selection. Result: Among the 3034 patients involved, 1996 (68.2%) were sensitized to at least one allergen. Overall, eight allergens (grass pollen, Dermatophagoides pteronyssinus, birch pollen, cat dander, Artemisia, olive pollen, Blatella and Alternaria) allowed to identified more than 95...

  13. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Hockgeiger, E.

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 °C and at 3 °C battery temperature.

  14. Neglected Parasitic Infections: Toxocariasis

    Centers for Disease Control (CDC) Podcasts

    2012-01-05

    This podcast is an overview of the Clinician Outreach and Communication Activity (COCA) Call: Neglected Parasitic Infections in the United States. Neglected Parasitic Infections are a group of diseases that afflict vulnerable populations and are often not well studied or diagnosed. A subject matter expert from CDC's Division of Parasitic Diseases and Malaria describes the epidemiology, diagnosis, and treatment of toxocariasis.  Created: 1/5/2012 by Center for Global Health, Division of Parasitic Diseases and Malaria (DPDM); Emergency Risk Communication Branch (ERCB)/Joint Information Center (JIC), Office of Public Health Preparedness and Response (OPHPR).   Date Released: 1/9/2012.

  15. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults

    Science.gov (United States)

    Mueller, Shane T.; Geerken, Alexander R.; Dixon, Kyle L.; Kroliczak, Gregory; Olsen, Reid H.J.; Miller, Jeremy K.

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18–22). Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance. PMID:26713233

  16. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults

    Directory of Open Access Journals (Sweden)

    Brian J. Piper

    2015-12-01

    Full Text Available Background. The Psychology Experiment Building Language (PEBL software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures.Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity, attention (Test of Attentional Vigilance and Time-Wall, working memory (Digit Span Forward, and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation in a normative sample (N = 189, ages 18–22. Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22.Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89 and Mental Rotation (d = 0.31 tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86 and attention (Test of Attentional Vigilance response time r = .79, intermediate for memory (digit span r = .63 but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15. Significant practice effects were identified on several indices of executive function.Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net is a versatile research tool to study individual differences in neurocognitive performance.

  17. Unilateral spatial neglect after posterior parietal damage.

    Science.gov (United States)

    Vallar, Giuseppe; Calzolari, Elena

    2018-01-01

    Unilateral spatial neglect is a disabling neurologic deficit, most frequent and severe after right-hemispheric lesions. In most patients neglect involves the left side of space, contralateral to a right-hemispheric lesion. About 50% of stroke patients exhibit neglect in the acute phase. Patients fail to orient, respond to, and report sensory events occurring in the contralateral sides of space and of the body, to explore these portions of space through movements by action effectors (eye, limbs), and to move the contralateral limbs. Neglect is a multicomponent higher-level disorder of spatial awareness, cognition, and attention. Spatial neglect may occur independently of elementary sensory and motor neurologic deficits, but it can mimic and make them more severe. Diagnostic tests include: motor exploratory target cancellation; setting the midpoint of a horizontal line (bisection), that requires the estimation of lateral extent; drawing by copy and from memory; reading, assessing neglect dyslexia; and exploring the side of the body contralateral to the lesion. Activities of daily living scales are also used. Patients are typically not aware of neglect, although they may exhibit varying degrees of awareness toward different components of the deficit. The neural correlates include lesions to the inferior parietal lobule of the posterior parietal cortex, which was long considered the unique neuropathologic correlate of neglect, to the premotor and to the dorsolateral prefrontal cortices, to the posterior superior temporal gyrus, at the temporoparietal junction, to subcortical gray nuclei (thalamus, basal ganglia), and to parietofrontal white-matter fiber tracts, such as the superior longitudinal fascicle. Damage to the inferior parietal lobule of the posterior parietal cortex is specifically associated with the mainly egocentric, perceptual, and exploratory extrapersonal, and with the personal, bodily components of neglect. Productive manifestations, such as

  18. Dental neglect among children in Chennai

    Directory of Open Access Journals (Sweden)

    Deepa Gurunathan

    2016-01-01

    Full Text Available Background: Child dental neglect is the failure of a parent or guardian to meet the child′s basic oral health needs such that the child enjoys adequate function and freedom from pain and infection, where reasonable resources are available to family or caregiver. Aim: The aim of the study is to evaluate the phenomenon of dental neglect among children in Chennai and to associate dental neglect with oral health status of children aged 3-12 years. Materials and Methods: This is a cross-sectional study involving 478 pairs of parents and children. Dental neglect scale and a questionnaire were used to assess the dental neglect score among parents of the children involved in the study. Oral health status of children was clinically assessed using oral hygiene index, decayed, extracted, filled teeth (def(t, pulp, ulcers, fistula, abscess (pufa, decayed, missing, filled teeth (DMFT, PUFA as per the World Health Organization criteria and pufa/PUFA index. Student′s t-test and one-way ANOVA were used appropriately for statistical analysis using SPSS software version 20.0. Results: A significant higher dental neglect score was reported among the parents who reside in the suburban location (P 3 years (P = 0.001. A significant higher DMFT (P = 0.003, deft (P = 0 < 0.001, pufa (P = 0.011, and debris index (P = 0.002 scores were seen in the higher dental neglect group. Conclusion: Child dental neglect is seen among the parents whose educational qualification was secondary, who reside in the suburban location, and who have not utilized the dental services for more than 3 years in Chennai. This dental neglect results in poorer oral health of children.

  19. Battery Modeling

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.

    2008-01-01

    The use of mobile devices is often limited by the capacity of the employed batteries. The battery lifetime determines how long one can use a device. Battery modeling can help to predict, and possibly extend this lifetime. Many different battery models have been developed over the years. However,

  20. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan

    Directory of Open Access Journals (Sweden)

    Moore AL

    2018-02-01

    Full Text Available Amy Lawson Moore, Terissa M Miller Gibson Institute of Cognitive Research, Colorado Springs, CO, USA Purpose: The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills.Methods: This study included 2,737 participants aged 5–85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test–retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement.Results: Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test–retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93.Conclusion: The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan. Keywords: testing, cognitive skills, memory, processing speed, visual processing, auditory processing

  1. Norms for a neuropsychological test battery to diagnose dementia in the elderly: A study from Sri Lanka

    Directory of Open Access Journals (Sweden)

    Srikanth Srinivasan

    2015-01-01

    Full Text Available Aims: To pilot a neuropsychological battery for diagnosing dementia and provide normative scores in an elderly Sri Lankan sample. Materials and Methods: Consecutive subjects over the age of 60 yrs were administered tests assessing the individual domains of language, verbal episodic memory, visual perceptuospatial skills and executive functions in the Sinhala language. Results: There were a total of 230 subjects in the final sample. The mean age of the entire sample was 69 years, mean education level was 12 years and the sample comprised 53% female. One-month test-retest reliability ranged from 0.71 to 0.85 for the various tests. Most tests were significantly influenced by age and education level but not gender. The exceptions to this were some language subtests (repetition, grammar comprehension and word picture matching and two tests of executive functioning (maze completion and alternate target cancellation, which were uninfluenced by age. The subtests where ceiling performance was attained by almost all subjects were repetition, grammar comprehension and word picture matching from the language domain, dot position discrimination from the visuospatial domain and maze completion test from the executive function domain. Scores for various tests after stratifying subjects by age and educational level are given. Conclusions: The tests were well received and could provide a basis for cognitive profiling in similar settings elsewhere.

  2. Energy Management of a Hybrid AC–DC Micro-Grid Based on a Battery Testing System

    Directory of Open Access Journals (Sweden)

    Bo Long

    2015-02-01

    Full Text Available Energy Recovery Battery Testing Systems (ERBTS plays an important role in battery manufacture. The conventional ERBTS configuration contains a fundamental transformer, and a bidirectional Direct Current (DC–DC and Alternating Current (AC–DC converter. All ERBTS are connected in parallel, thus constituting a special and complicated AC micro-grid system. Aiming at addressing their low energy recovery efficiency, complex grid-connected control algorithm issues for islanded detection, and complicated power circuit topology issues, a hierarchical DC-link voltage hybrid AC–DC micro-grid that contains composite energy storing devices is proposed. Moreover, an energy management optimal scheme for the proposed scheme is put forward. The system configuration of the proposed scheme is described in detail. Compared to the conventional scheme, the proposed scheme has the merits of simplified power circuit topology, no need for phase synchronous control, and much higher energy recovery efficiency and reliability. The validity and effectiveness of the proposed technique is verified through numerous experimental results.

  3. Vibration Durability Testing of Nickel Manganese Cobalt Oxide (NMC Lithium-Ion 18,650 Battery Cells

    Directory of Open Access Journals (Sweden)

    James Michael Hooper

    2016-01-01

    Full Text Available Electric vehicle (EV manufacturers are employing cylindrical format cells in the construction of the vehicles’ battery systems. There is evidence to suggest that both the academic and industrial communities have evaluated cell degradation due to vibration and other forms of mechanical loading. The primary motivation is often the need to satisfy the minimum requirements for safety certification. However, there is limited research that quantifies the durability of the battery and in particular, how the cells will be affected by vibration that is representative of a typical automotive service life (e.g., 100,000 miles. This paper presents a study to determine the durability of commercially available 18,650 cells and quantifies both the electrical and mechanical vibration-induced degradation through measuring changes in cell capacity, impedance and natural frequency. The impact of the cell state of charge (SOC and in-pack orientation is also evaluated. Experimental results are presented which clearly show that the performance of 18,650 cells can be affected by vibration profiles which are representative of a typical vehicle life. Consequently, it is recommended that EV manufacturers undertake vibration testing, as part of their technology selection and development activities to enhance the quality of EVs and to minimize the risk of in-service warranty claims.

  4. The Neglect of Virtue

    Science.gov (United States)

    Sockett, Hugh

    2013-01-01

    This chapter argues that schooling neglects virtue through the dominant quest for right answers. This is not only intellectually disreputable in presuming the correctness of what is taught, but it undermines the development of necessary intellectual virtues, such as open-mindedness, impartiality, and accuracy in the school curriculum, and it fails…

  5. Neglected bacterial zoonoses.

    Science.gov (United States)

    Chikeka, I; Dumler, J S

    2015-05-01

    Bacterial zoonoses comprise a group of diseases in humans or animals acquired by direct contact with or by oral consumption of contaminated animal materials, or via arthropod vectors. Among neglected infections, bacterial zoonoses are among the most neglected given emerging data on incidence and prevalence as causes of acute febrile illness, even in areas where recognized neglected tropical diseases occur frequently. Although many other bacterial infections could also be considered in this neglected category, five distinct infections stand out because they are globally distributed, are acute febrile diseases, have high rates of morbidity and case fatality, and are reported as commonly as malaria, typhoid or dengue virus infections in carefully designed studies in which broad-spectrum diagnoses are actively sought. This review will focus attention on leptospirosis, relapsing fever borreliosis and rickettsioses, including scrub typhus, murine typhus and spotted fever group rickettsiosis. Of greatest interest is the lack of distinguishing clinical features among these infections when in humans, which confounds diagnosis where laboratory confirmation is lacking, and in regions where clinical diagnosis is often attributed to one of several perceived more common threats. As diseases such as malaria come under improved control, the real impact of these common and under-recognized infections will become evident, as will the requirement for the strategies and allocation of resources for their control. Copyright © 2015 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  6. Performance on Cambridge Neuropsychological Test Automated Battery Subtests Sensitive to Frontal Lobe Function in People with Autistic Disorder: Evidence from the Collaborative Programs of Excellence in Autism Network

    Science.gov (United States)

    Ozonoff, Sally; Cook, Ian; Coon, Hilary; Dawson, Geraldine; Joseph, Robert M.; Klin, Ami; McMahon, William M.; Minshew, Nancy; Munson, Jeffrey A.

    2004-01-01

    Recent structural and functional imaging work, as well as neuropathology and neuropsychology studies, provide strong empirical support for the involvement of frontal cortex in autism. The Cambridge Neuropsychological Test Automated Battery (CANTAB) is a computer-administered set of neuropsychological tests developed to examine specific components…

  7. An Update of the Ground Testing of the Li-ion Batteries in Support of JPL's 2003 Mars Exploration Rover Mission

    Science.gov (United States)

    Smart, Marshall C.; Ratnakumar, B. V.; Ewell, R. C.; Whitcanack, L. D.; Surampudi, S.; Puglia, F.; Gitzendanner, R.

    2006-01-01

    In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration (>9 months), both Rovers are equipped with rechargeable Lithium-ion batteries, which have enabled operation for over 854 and 834 Sols of operation, respectively, to date. Given that the batteries were required to support the mission for 90 Sols of operation by design, it is significant that the batteries have demonstrated over a nine fold increase in life over mission objectives. In addition to supporting the surface operations in conjunction with a triple-junction deployable solar arrays, the batteries were designed to aid in the launch and the EDL pyros, and allow for anomalies during cruise. In summary, the requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20 C to +30 C), withstand long storage periods (e.g., cruise period), operate in an inverted orientation, and support high current pulses (e.g., firing pyro events). In order to determine the viability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit (RBAU), consisting of two 8-cell 10 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The testing includes, (a) performing initial characterization tests (discharge capacity at different temperatures), (b) simulating the launch conditions, (c) simulating the cruise phase conditions (including trajectory correction maneuvers), (d) simulating the entry, decent, and landing (EDL) pulse load profile (required to support the pyros) (e) simulating the Mars surface operation mission simulation conditions, as well as, (f) assessing capacity loss and impedance characteristics as

  8. Research and development of a phosphoric acid fuel cell/battery power source integrated in a test-bed bus. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-30

    This project, the research and development of a phosphoric acid fuel cell/battery power source integrated into test-bed buses, began as a multi-phase U.S. Department of Energy (DOE) project in 1989. Phase I had a goal of developing two competing half-scale (25 kW) brassboard phosphoric acid fuel cell systems. An air-cooled and a liquid-cooled fuel cell system were developed and tested to verify the concept of using a fuel cell and a battery in a hybrid configuration wherein the fuel cell supplies the average power required for operating the vehicle and a battery supplies the `surge` or excess power required for acceleration and hill-climbing. Work done in Phase I determined that the liquid-cooled system offered higher efficiency.

  9. Ecological risk assessment of organic waste amendments using the species sensitivity distribution from a soil organisms test battery

    International Nuclear Information System (INIS)

    Domene, Xavier; Ramirez, Wilson; Mattana, Stefania; Alcaniz, Josep Maria; Andres, Pilar

    2008-01-01

    Safe amendment rates (the predicted no-effect concentration or PNEC) of seven organic wastes were estimated from the species sensitivity distribution of a battery of soil biota tests and compared with different realistic amendment scenarios (different predicted environmental concentrations or PEC). None of the wastes was expected to exert noxious effects on soil biota if applied according either to the usual maximum amendment rates in Europe or phosphorus demands of crops (below 2 tonnes DM ha -1 ). However, some of the wastes might be problematic if applied according to nitrogen demands of crops (above 2 tonnes DM ha -1 ). Ammonium content and organic matter stability of the studied wastes are the most influential determinants of the maximum amendment rates derived in this study, but not pollutant burden. This finding indicates the need to stabilize wastes prior to their reuse in soils in order to avoid short-term impacts on soil communities. - Ecological risk assessment of organic waste amendments

  10. A core in vitro genotoxicity battery comprising the Ames test plus the in vitro micronucleus test is sufficient to detect rodent carcinogens and in vivo genotoxins.

    Science.gov (United States)

    Kirkland, David; Reeve, Lesley; Gatehouse, David; Vanparys, Philippe

    2011-03-18

    In vitro genotoxicity testing needs to include tests in both bacterial and mammalian cells, and be able to detect gene mutations, chromosomal damage and aneuploidy. This may be achieved by a combination of the Ames test (detects gene mutations) and the in vitro micronucleus test (MNvit), since the latter detects both chromosomal aberrations and aneuploidy. In this paper we therefore present an analysis of an existing database of rodent carcinogens and a new database of in vivo genotoxins in terms of the in vitro genotoxicity tests needed to detect their in vivo activity. Published in vitro data from at least one test system (most were from the Ames test) were available for 557 carcinogens and 405 in vivo genotoxins. Because there are fewer publications on the MNvit than for other mammalian cell tests, and because the concordance between the MNvit and the in vitro chromosomal aberration (CAvit) test is so high for clastogenic activity, positive results in the CAvit test were taken as indicative of a positive result in the MNvit where there were no, or only inadequate data for the latter. Also, because Hprt and Tk loci both detect gene-mutation activity, a positive Hprt test was taken as indicative of a mouse-lymphoma Tk assay (MLA)-positive, where there were no data for the latter. Almost all of the 962 rodent carcinogens and in vivo genotoxins were detected by an in vitro battery comprising Ames+MNvit. An additional 11 carcinogens and six in vivo genotoxins would apparently be detected by the MLA, but many of these had not been tested in the MNvit or CAvit tests. Only four chemicals emerge as potentially being more readily detected in MLA than in Ames+MNvit--benzyl acetate, toluene, morphine and thiabendazole--and none of these are convincing cases to argue for the inclusion of the MLA in addition to Ames+MNvit. Thus, there is no convincing evidence that any genotoxic rodent carcinogens or in vivo genotoxins would remain undetected in an in vitro test battery

  11. Unilateral neglect and perceptual parsing: a large-group study.

    Science.gov (United States)

    Neppi-Mòdona, Marco; Savazzi, Silvia; Ricci, Raffaella; Genero, Rosanna; Berruti, Giuseppina; Pepi, Riccardo

    2002-01-01

    Array-centred and subarray-centred neglect were disambiguated in a group of 116 patients with left neglect by means of a modified version of the Albert test in which the central column of segments was deleted so as to create two separate sets of targets grouped by proximity. The results indicated that neglect was more frequent in array- than subarray-centred coordinates and that, in a minority of cases, neglect co-occurred in both coordinate-systems. The two types of neglect were functionally but not anatomically dissociated. Presence of visual field defects was not prevalent in one type of neglect with respect to the other. These data contribute further evidence to previous single-case and small-group studies by showing that neglect can occur in single or multiple reference frames simultaneously, in agreement with current neuropsychological, neurophysiological and computational concepts of space representation.

  12. The Harvard Beat Assessment Test (H-BAT: A Battery for Assessing Beat Perception and Production and their Dissociation

    Directory of Open Access Journals (Sweden)

    Shinya eFujii

    2013-11-01

    Full Text Available Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT, a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: 1 music tapping test (MTT, 2 beat saliency test (BST, 3 beat interval test (BIT, and 4 beat finding and interval test (BFIT. MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual’s ability to perceive and produce a beat within a single session.

  13. Care neglect, supervisory neglect, and harsh parenting in the development of children's aggression: a replication and extension.

    Science.gov (United States)

    Knutson, John F; DeGarmo, David; Koeppl, Gina; Reid, John B

    2005-05-01

    To understand the effects of neglectful parenting, poor supervision, and punitive parenting in the development of children's aggression, 218 children ages 4 to 8 years who were disadvantaged and their mothers were recruited from two states to develop a sample that was diverse with respect to degree of urbanization and ethnicity. Multimethod and multisource indices of the predictive constructs (Social Disadvantage, Denial of Care Neglect, Supervisory Neglect, and Punitive Discipline) and the criterion construct (Aggression) were used in a test of a theoretical model using structural equation modeling. The results established the role of care neglect, supervisory neglect, and punitive parenting as mediators of the role of social disadvantage in the development of children's aggression, the importance of distinguishing between two subtypes of neglect, and the need to consider the role of discipline in concert with neglect when attempting to understand the parenting in the development of aggression.

  14. The Facial Expression Action Stimulus Test. A test battery for the assessment of face memory, face and object perception, configuration processing and facial expression recognition

    Directory of Open Access Journals (Sweden)

    Beatrice eDe Gelder

    2015-10-01

    Full Text Available There are many ways to assess face perception skills. In this study, we describe a novel task battery FEAST (Facial Expression Action Stimulus Test developed to test recognition of identity and expressions of human faces as well as stimulus control categories. The FEAST consists of a neutral and emotional face memory task, a face and object identity matching task, a face and house part-to-whole matching task, and a human and animal facial expression matching task. The identity and part-to-whole matching tasks contain both upright and inverted conditions. The results provide reference data of a healthy sample of controls in two age groups for future users of the FEAST.

  15. A music quality rating test battery for cochlear implant users to compare the FSP and HDCIS strategies for music appreciation.

    Science.gov (United States)

    Looi, Valerie; Winter, Philip; Anderson, Ilona; Sucher, Catherine

    2011-08-01

    The purpose of this study was to develop a music quality rating test battery (MQRTB) and pilot test it by comparing appraisal ratings from cochlear implant (CI) recipients using the fine-structure processing (FSP) and high-definition continuous interleaved sampling (HDCIS) speech processing strategies. The development of the MQRTB involved three stages: (1) Selection of test items for the MQRTB; (2) Verification of its length and complexity with normally-hearing individuals; and (3) Pilot testing with CI recipients. Part 1 involved 65 adult listeners, Part 2 involved 10 normally-hearing adults, and Part 3 involved five adult MED-EL CI recipients. The MQRTB consisted of ten songs, with ratings made on scales assessing pleasantness, naturalness, richness, fullness, sharpness, and roughness. Results of the pilot study, which compared FSP and HDCIS for music, indicated that acclimatization to a strategy had a significant effect on ratings (p genre on ratings. Overall the results suggest that the use of FSP as the default strategy for MED-EL recipients would have a positive effect on music appreciation, and that the MQRTB is an effective tool for assessing music sound quality.

  16. Fabrication and test of inorganic/organic separators. [for silver zinc batteries

    Science.gov (United States)

    Smatko, J. S.

    1974-01-01

    Completion of testing and failure analysis of MDC 40 Ahr silver zinc cells containing largely inorganic separators was accomplished. The results showed that the wet stand and cycle life objectives of the silver zinc cell development program were accomplished. Building, testing and failure analysis of two plate cells employing three optimum separators selected on the basis of extensive screening tests, was performed. The best separator material as a result of these tests was doped calcium zirconate.

  17. Hop performance and leg muscle power in athletes: Reliability of a test battery.

    Science.gov (United States)

    Kockum, Britta; Heijne, Annette I-L M

    2015-08-01

    To measure the absolute and relative reliability and the smallest real difference (SRD) in three commonly used hop tests, two leg-power tests and the single-leg squat jump. Methodological study. Clinical setting. Fourteen healthy athletes (seven women and seven men) were evaluated in a standardized test-retest design. The Intra-class correlation coefficient (ICC2.1), Standard Error of Measurement (SEM) and SRD were calculated for the vertical jump, one-leg hop for distance, side-hop, single-leg squat jump and knee-flexion and knee-extension power tests. All tests showed good to excellent ICC (0.84-0.98). The SEM (%) ranged between 3.4 and 11.1 for the four hop tests and between 8.1 and 12.4 for the leg-power tests. The SRD (%) for the hop tests ranged between 9.3 and 30.7 and for the three power tests between 22.4 and 34.3. The absolute reliability of this test protocol showed good to excellent ICC values and measurement errors of approximately 10%. This instrument can be recommended for determining function in terms of power in healthy athletes or late in the rehabilitation process. The tests' methodological errors must be considered and caution should be taken regarding the standardization procedure during testing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Identification of an abbreviated test battery for detection of HIV-associated neurocognitive impairment in an early-managed HIV-infected cohort.

    Directory of Open Access Journals (Sweden)

    David J Moore

    Full Text Available HIV-associated neurocognitive disorders (HAND remain prevalent despite improved antiretroviral treatment (ART, and it is essential to have a sensitive and specific HAND screening tool.Participants were 200 HIV-infected US military beneficiaries, managed early in the course of HIV infection, had few comorbidities, and had open access to ART. Participants completed a comprehensive, seven-domain (16-test, neuropsychological battery (∼120 min; neurocognitive impairment (NCI was determined using a standardized score derived from demographically adjusted T-scores (global deficit score ≥0.5. Restricting the estimated administration time of the screening battery to < = 20 minutes, we examined the sensitivity and specificity of detecting NCI for all possible combinations of 2-, 3-, and 4- tests from the comprehensive battery.Participants were relatively healthy (median CD4 count: 546 cells/mm(3 with 64% receiving ART. Prevalence of NCI was low (19%. The best 2-test screener included the Stroop Color Test and the Hopkins Verbal Learning Test-Revised (11 min; sensitivity = 73%; specificity = 83%; the best 3-test screener included the above measures plus the Paced Auditory Serial Addition Test (PASAT; 16 min; sensitivity = 86%; specificity = 75%. The addition of Action Fluency to the above three tests improved specificity (18 min; sensitivity = 86%; specificity = 87%.Combinations of widely accepted neuropsychological tests with brief implementation time demonstrated good sensitivity and specificity compared to a time intensive neuropsychological test battery. Tests of verbal learning, attention/working memory, and processing speed are particularly useful in detecting NCI. Utilizing validated, easy to administer, traditional neuropsychological tests with established normative data may represent an excellent approach to screening for NCI in HIV.

  19. Cognitive Dysfunction after On-Pump Operations: Neuropsychological Characteristics and Optimal Core Battery of Tests

    Directory of Open Access Journals (Sweden)

    Anna G. Polunina

    2014-01-01

    Full Text Available Postoperative cognitive dysfunction (POCD is a mild form of perioperative ischemic brain injury, which emerges as memory decline, decreased attention, and decreased concentration during several months, or even years, after surgery. Here we present results of our three neuropsychological studies, which overall included 145 patients after on-pump operations. We found that the auditory memory span test (digit span was more effective as a tool for registration of POCD, in comparison with the word-list learning and story-learning tests. Nonverbal memory or visuoconstruction tests were sensitive to POCD in patients after intraoperative opening of cardiac chambers with increased cerebral air embolism. Psychomotor speed tests (digit symbol, or TMT A registered POCD, which was characteristic for elderly atherosclerotic patients. Finally, we observed that there were significant effects of the order of position of a test on the performance on this test. For example, the postoperative performance on the core tests (digit span and digit symbol showed minimal impairment when either of these tests was administered at the beginning of testing. Overall, our data shows that the selection of tests, and the order of which these tests are administered, may considerably influence the results of studies of POCD.

  20. Impact of different cutoff criteria on rate of (central auditory processing disorders diagnosis using the central test battery

    Directory of Open Access Journals (Sweden)

    Mohsin Ahmed Shaikh

    2016-11-01

    Full Text Available The purpose of this study was to quantify how the use of two different cutoff criteria affects the test failure rate and potential diagnosis of central auditory processing disorder ([C]APD in a sample of children subjected to central auditory processing ([C]AP assessment. Test failure rates for the central test battery (CTB using two different cutoff criteria (1 and 2 SDs below the mean were measured retrospectively for 98 children who completed (CAP assessment. The rates of potential (CAPD diagnosis ranged from 86.8% [when a 1 standard deviation (SD cutoff was used] to 66.2% (when a 2 SD cutoff was used. The current use of two different cutoffs for the CTB has a large impact on the diagnostic rate for (CAPD. These findings have clinical implications for the diagnosis of (CAPD due to the widespread use of the CTB in the United States for the assessment of (CAPD in children. Thus, it is important to create awareness among audiologists that use of the 2 SDs cutoff criterion is recommended for reducing false positives (error.

  1. 78 FR 58574 - Maintenance, Testing, and Replacement of Vented Lead-Acid Storage Batteries for Nuclear Power Plants

    Science.gov (United States)

    2013-09-24

    ...-Acid Storage Batteries for Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION... for Nuclear Power Plants.'' The guide describes methods that the NRC staff considers acceptable for... replacement of vented lead-acid storage batteries in nuclear power plants. ADDRESSES: Please refer to Docket...

  2. Semiology of neglect: An update.

    Science.gov (United States)

    Rode, G; Pagliari, C; Huchon, L; Rossetti, Y; Pisella, L

    2017-06-01

    Hemispatial neglect is a common disabling condition following brain damage to the right hemisphere. Generally, it involves behavioral bias directed ipsilaterally to the damaged hemisphere and loss of spatial awareness for the contralesional side. In this syndrome, several clinical subtypes were identified. The objective of this article is to provide a nosological analysis of the recent data from the literature on the different subtypes of neglect (visual, auditory, somatosensory, motor, egocentric, allocentric and representational neglect), associated ipsilesional and contralesional productive manifestations and their anatomical lesion correlates. These different anatomical-clinical subtypes can be associated or dissociated. They reflect the heterogeneity of this unilateral neglect syndrome that cannot be approached or interpreted in a single manner. We propose that these subtypes result from different underlying deficits: exogenous attentional deficit (visual, auditory neglect); representational deficit (personal neglect, representational neglect, hyperschematia); shift of the egocentric reference frame (egocentric neglect); attentional deficit between objects and within objects (allocentric neglect), endogenous attentional deficit (representational neglect) and transsaccadic working memory or spatial remapping deficit (ipsilesional productive manifestations). Taking into account the different facets of the unilateral neglect syndrome should promote the development of more targeted cognitive rehabilitation protocols. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. Simulating hemispatial neglect with virtual reality

    Directory of Open Access Journals (Sweden)

    Yoshizawa Makoto

    2007-07-01

    Full Text Available Abstract Background Hemispatial neglect is a cognitive disorder defined as a lack of attention for stimuli contra-lateral to the brain lesion. The assessment is traditionally done with basic pencil and paper tests and the rehabilitation programs are generally not well adapted. We propose a virtual reality system featuring an eye-tracking device for a better characterization of the neglect that will lead to new rehabilitation techniques. Methods This paper presents a comparison of eye-gaze patterns of healthy subjects, patients and healthy simulated patients on a virtual line bisection test. The task was also executed with a reduced visual field condition hoping that fewer stimuli would limit the neglect. Results We found that patients and healthy simulated patients had similar eye-gaze patterns. However, while the reduced visual field condition had no effect on the healthy simulated patients, it actually had a negative impact on the patients. We discuss the reasons for these differences and how they relate to the limitations of the neglect simulation. Conclusion We argue that with some improvements the technique could be used to determine the potential of new rehabilitation techniques and also help the rehabilitation staff or the patient's relatives to better understand the neglect condition.

  4. Testing ESL pragmatics development and validation of a web-based assessment battery

    CERN Document Server

    Roever, Carsten

    2014-01-01

    Although second language learners' pragmatic competence (their ability to use language in context) is an essential part of their general communicative competence, it has not been a part of second language tests. This book helps fill this gap by describing the development and validation of a web-based test of ESL pragmalinguistics. The instrument assesses learners' knowledge of routine formulae, speech acts, and implicature in 36 multiple-choice and brief-response items. The test's quantitative and qualitative validation with 300 learners showed high reliability and provided strong evidence of

  5. Design and Control of a Multi-Functional Energy Recovery Power Accumulator Battery Pack Testing System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Bo Long

    2014-03-01

    Full Text Available In this paper, aiming at the energy loss and harmonic problems in the conventional power accumulator battery pack testing system (PABPTS, an improved multi-functional energy recovery PABPTS (ERPABPTS for electric vehicles (EVs was proposed. The improved system has the functions of harmonic detection, suppression, reactive compensation and energy recovery. The ERPABPTS, which contains a bi-directional buck-boost direct current (DC-DC converter and a bi-directional alternating current (AC-DC converter with an inductor-capacitor-inductor (LCL type filter interfacing to the AC-grid, is proposed. System configuration and operation principle of the combined system are discussed first, then, the reactive compensation and harmonic suppression controller under balanced grid-voltage condition are presented. Design of a fourth order band-pass Butterworth filter for current harmonic detection is put forward, and the reactive compensator design procedure considering the non-linear load is also illustrated. The proposed scheme is implemented in a 175-kW prototype in the laboratory. Simulation and experimental results show that the combined configuration can effectively realize energy recovery for high accuracy current test requirement, meanwhile, can effectively achieve reactive compensation and current harmonic suppression.

  6. The Effect of Presentation Medium on Pilot Selection Test Battery Scores

    National Research Council Canada - National Science Library

    Biggerstaff, S

    1998-01-01

    .... The American Psychological Association (APA) has set guidelines to be followed to ensure both qualitative and quantitative equivalence of new test formats prior to their use in applied settings...

  7. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    NARCIS (Netherlands)

    Bousquet, P.-J.; Burbach, G.; Heinzerling, L. M.; Edenharter, G.; Bachert, C.; Bindslev-Jensen, C.; Bonini, S.; Bousquet-Rouanet, L.; Demoly, P.; Bresciani, M.; Bruno, A.; Gjomarkaj, M.; Canonica, G. W.; Darsow, U.; Durham, S.; Fokkens, W. J.; Giavi, S.; Gramiccioni, C.; Papadopoulos, N. G.; Haahtela, T.; Kowalski, M. L.; Magyar, P.; Muraközi, G.; Orosz, M.; Röhnelt, C.; Stingl, G.; Todo-Bom, A.; von Mutius, E.; Wiesner, A.; Wöhrl, S.; Bousquet, J.; Zuberbier, T.

    2009-01-01

    Background: The number of allergens to be tested in order to identify sensitized patients is important in order to have the most cost-effective approach in epidemiological studies. Objective: To define the minimal number and the type of skin prick test (SPT) allergens required to identify a patient

  8. Relations Between the Intelligibility of Speech in Noise and Psychophysical Measures of Hearing Measured in Four Languages Using the Auditory Profile Test Battery

    OpenAIRE

    T. E. M. Van Esch; W. A. Dreschler

    2015-01-01

    The aim of the present study was to determine the relations between the intelligibility of speech in noise and measures of auditory resolution, loudness recruitment, and cognitive function. The analyses were based on data published earlier as part of the presentation of the Auditory Profile, a test battery implemented in four languages. Tests of the intelligibility of speech, resolution, loudness recruitment, and lexical decision making were measured using headphones in five centers: in Germa...

  9. Dry cell battery poisoning

    Science.gov (United States)

    Batteries - dry cell ... Acidic dry cell batteries contain: Manganese dioxide Ammonium chloride Alkaline dry cell batteries contain: Sodium hydroxide Potassium hydroxide Lithium dioxide dry cell batteries ...

  10. When Is Neglect, Neglect?: It Depends on Who You Ask.

    Science.gov (United States)

    Dickerson, Kelli L; Lindner, Sonia; Scurich, Nicholas; Quas, Jodi A

    2017-08-01

    In order to identify victims of child neglect, social service workers rely heavily on referrals from concerned friends, neighbors, and others in the community. Little is known, however, about how lay individuals perceive child neglect and what factors influence their decision to make a referral. This study explored the effects of child, parent, and participant gender on laypersons' evaluations of child neglect. Participants read a case of neglect of a child by a custodial and absent parent and then rated the parents' culpability and intentionality and decided whether the parents' behavior met the legal definition of neglect. When evaluating the custodial parent, men but not women viewed fathers as more culpable than mothers for the neglect of their son and viewed mothers as somewhat more culpable for the neglect of their daughter. Men also perceived absent mothers as more intentionally harmful than absent fathers. Finally, both men and women were more likely to qualify parental behavior as legally neglectful when the genders of the custodial parent and child matched. Results, which suggest that gender bias may exist in laypersons' perceptions of child neglect and may influence their decisions to report, have implications for identification of and intervention for vulnerable children and families.

  11. High performance Li3V2(PO4)3/C composite cathode material for lithium ion batteries studied in pilot scale test

    International Nuclear Information System (INIS)

    Chen Zhenyu; Dai Changsong; Wu Gang; Nelson, Mark; Hu Xinguo; Zhang Ruoxin; Liu Jiansheng; Xia Jicai

    2010-01-01

    Li 3 V 2 (PO 4 ) 3 /C composite cathode material was synthesized via carbothermal reduction process in a pilot scale production test using battery grade raw materials with the aim of studying the feasibility for their practical applications. XRD, FT-IR, XPS, CV, EIS and battery charge-discharge tests were used to characterize the as-prepared material. The XRD and FT-IR data suggested that the as-prepared Li 3 V 2 (PO 4 ) 3 /C material exhibits an orderly monoclinic structure based on the connectivity of PO 4 tetrahedra and VO 6 octahedra. Half cell tests indicated that an excellent high-rate cyclic performance was achieved on the Li 3 V 2 (PO 4 ) 3 /C cathodes in the voltage range of 3.0-4.3 V, retaining a capacity of 95% (96 mAh/g) after 100 cycles at 20C discharge rate. The low-temperature performance of the cathode was further evaluated, showing 0.5C discharge capacity of 122 and 119 mAh/g at -25 and -40 o C, respectively. The discharge capacity of graphite//Li 3 V 2 (PO 4 ) 3 batteries with a designed battery capacity of 14 Ah is as high as 109 mAh/g with a capacity retention of 92% after 224 cycles at 2C discharge rates. The promising high-rate and low-temperature performance observed in this work suggests that Li 3 V 2 (PO 4 ) 3 /C is a very strong candidate to be a cathode in a next-generation Li-ion battery for electric vehicle applications.

  12. Executive Functions as Endophenotypes in ADHD: Evidence from the Cambridge Neuropsychological Test Battery (CANTAB)

    Science.gov (United States)

    Gau, Susan Shur-Fen; Shang, Chi-Yung

    2010-01-01

    Background: Little is known about executive functions among unaffected siblings of children with attention deficit/hyperactivity disorder (ADHD), and there is lack of such information from non-Western countries. We examined verbal and nonverbal executive functions in adolescents with ADHD, unaffected siblings and controls to test whether executive…

  13. The placenta in toxicology. Part IV : Battery of toxicological test systems based on human placenta

    NARCIS (Netherlands)

    Göhner, Claudia; Svensson-Arvelund, Judit; Pfarrer, Christiane; Häger, Jan-Dirk; Faas, Marijke; Ernerudh, Jan; Cline, J Mark; Dixon, Darlene; Buse, Eberhard; Markert, Udo R

    This review summarizes the potential and also some limitations of using human placentas, or placental cells and structures for toxicology testing. The placenta contains a wide spectrum of cell types and tissues, such as trophoblast cells, immune cells, fibroblasts, stem cells, endothelial cells,

  14. The Construction of a Motor Fitness Test Battery for Boys in the Lower Elementary Grades.

    Science.gov (United States)

    DiNucci, James M.; Shore, John Roger

    In order to construct a scientifically designed evaluative instrument to assess the motor fitness of boys in the primary grades, 30 test items purported to measure muscular strength, muscular endurance, cardiovascular endurance, power, speed, agility, flexibility, and balance were administered to an incidental sample of 238 boys ages 6 to 9 years.…

  15. SPATIAL NEGLECT AND ATTENTION NETWORKS

    Science.gov (United States)

    Corbetta, Maurizio; Shulman, Gordon L.

    2013-01-01

    Unilateral spatial neglect is a common neurological syndrome following predominantly right hemisphere injuries to ventral fronto-parietal cortex. We propose that neglect reflects deficits in the coding of saliency, control of spatial attention, and representation within an egocentric frame of reference, in conjunction with non-spatial deficits of reorienting, target detection, and arousal/vigilance. In contrast to theories that link spatial neglect to structural damage of specific brain regions, we argue that neglect is better explained by the physiological dysfunction of distributed cortical networks. The ventral lesions in right parietal, temporal, and frontal cortex that cause neglect directly impair non-spatial functions and hypoactivate the right hemisphere, inducing abnormalities in task-evoked activity and functional connectivity of a dorsal frontal-parietal network that controls spatial attention. The anatomy and right hemisphere dominance of neglect follows from the anatomy and laterality of the ventral regions that interact with the dorsal attention network. PMID:21692662

  16. Hairy carbon electrodes studied by cyclic voltammetry and battery discharge testing

    Science.gov (United States)

    Chung, Deborah D. L.; Shui, Xiaoping; Frysz, Christine A.

    1993-01-01

    Hairy carbon is a new material developed by growing submicron carbon filaments on conventional carbon substrates. Typical substrate materials include carbon black, graphite powder, carbon fibers, and glassy carbon. A catalyst is used to initiate hair growth with carbonaceous gases serving as the carbon source. To study the electrochemical behavior of hairy carbons, cyclic voltammetry (CV) and discharge testing were conducted. In both cases, hairy carbon results surpassed those of the substrate material alone.

  17. Development of a test battery for evaluating speech perception in complex listening environments.

    Science.gov (United States)

    Brungart, Douglas S; Sheffield, Benjamin M; Kubli, Lina R

    2014-08-01

    In the real world, spoken communication occurs in complex environments that involve audiovisual speech cues, spatially separated sound sources, reverberant listening spaces, and other complicating factors that influence speech understanding. However, most clinical tools for assessing speech perception are based on simplified listening environments that do not reflect the complexities of real-world listening. In this study, speech materials from the QuickSIN speech-in-noise test by Killion, Niquette, Gudmundsen, Revit, and Banerjee [J. Acoust. Soc. Am. 116, 2395-2405 (2004)] were modified to simulate eight listening conditions spanning the range of auditory environments listeners encounter in everyday life. The standard QuickSIN test method was used to estimate 50% speech reception thresholds (SRT50) in each condition. A method of adjustment procedure was also used to obtain subjective estimates of the lowest signal-to-noise ratio (SNR) where the listeners were able to understand 100% of the speech (SRT100) and the highest SNR where they could detect the speech but could not understand any of the words (SRT0). The results show that the modified materials maintained most of the efficiency of the QuickSIN test procedure while capturing performance differences across listening conditions comparable to those reported in previous studies that have examined the effects of audiovisual cues, binaural cues, room reverberation, and time compression on the intelligibility of speech.

  18. Using basketball test battery to monitor players with mental retardation across 2 sports seasons.

    Science.gov (United States)

    Baldari, Carlo; Franciosi, Emanuele; Gallotta, Maria Chiara; Emerenziani, Gian Pietro; Reis, Victor Machado; Guidetti, Laura

    2009-11-01

    Although sport for athletes with mental retardation (MR) is achieving an important role, literature concerning basketball test and training is still poor. The aims of this study were to assess basketball ability before (PRE) and after (POST) a 6-month training in athletes with MR across 2 sports seasons (ss) and to analyze the variation of basketball abilities by subjects' MR level. Fifteen trained basketball players with MR participated (11 men and 4 women; age range 19-43 years; MR: 3 Mild, 8 Moderate, 3 Severe, and 1 Profound). Athletes were tested PRE and POST a 6-month training during 2 following sports seasons (ss1 and ss2). The tests assessed 4 ability levels, each one characterized by the analysis of 4 fundamental areas (ball handling, reception, passing, and shooting), divided into 5 specific components. The athletes' global score improved after training in both ss1 (41.5 +/- 12.0 vs. 48.6 +/- 15.4; p training caused a general improvement, especially evident in levels II and III in both ss. Global and level scores were negatively correlated to MR level (p training.

  19. [A standard questionnaire to reduce the routine battery of preoperative tests for elective surgery].

    Science.gov (United States)

    Torres-Ruiz, María Fernanda; Cárdenas-Lailson, Luis Eduardo; Quiróz-Villegas, Martha Esthela; Bravo-León, Jesús

    2014-01-01

    Preoperative medical testing in the United States is estimated at $3,000,000 USD per year. In an attempt to reduce this cost, some key points have been described with the purpose of promoting appropriate preoperative measurements with an adequate costObjective: To evaluate the utility of a preoperative standardized questionnaire in adult patients prior to elective surgery to detect which patients could be operated without laboratory testing. An observational, prospective and analytic study was carried out. The questionnaire has been applied to 176 patients, all adults scheduled for elective surgery from April 2011 to March 2012. There were 57.4% females and 42.6% males. Ages varied between 18 and 85 years old, with a median of 46 years; 40.3% of the patients were > 50 years old and 59.7% were < 50 years old. The negative predictive value of the questionnaire is 95.88% (CI 95.34-96.42%). This questionnaire is a useful instrument to determinate the necessity of preoperative laboratory testing in young, clinical healthy and elective surgery patients in a general hospital.

  20. Representational neglect for words as revealed by bisection tasks.

    Science.gov (United States)

    Arduino, Lisa S; Marinelli, Chiara Valeria; Pasotti, Fabrizio; Ferrè, Elisa Raffaella; Bottini, Gabriella

    2012-03-01

    In the present study, we showed that a representational disorder for words can dissociate from both representational neglect for objects and neglect dyslexia. This study involved 14 brain-damaged patients with left unilateral spatial neglect and a group of normal subjects. Patients were divided into four groups based on presence of left neglect dyslexia and representational neglect for non-verbal material, as evaluated by the Clock Drawing test. The patients were presented with bisection tasks for words and lines. The word bisection tasks (with words of five and seven letters) comprised the following: (1) representational bisection: the experimenter pronounced a word and then asked the patient to name the letter in the middle position; (2) visual bisection: same as (1) with stimuli presented visually; and (3) motor bisection: the patient was asked to cross out the letter in the middle position. The standard line bisection task was presented using lines of different length. Consistent with the literature, long lines were bisected to the right and short lines, rendered comparable in length to the words of the word bisection test, deviated to the left (crossover effect). Both patients and controls showed the same leftward bias on words in the visual and motor bisection conditions. A significant difference emerged between the groups only in the case of the representational bisection task, whereas the group exhibiting neglect dyslexia associated with representational neglect for objects showed a significant rightward bias, while the other three patient groups and the controls showed a leftward bisection bias. Neither the presence of neglect alone nor the presence of visual neglect dyslexia was sufficient to produce a specific disorder in mental imagery. These results demonstrate a specific representational neglect for words independent of both representational neglect and neglect dyslexia. ©2011 The British Psychological Society.

  1. Hypnosis: useful, neglected, available.

    Science.gov (United States)

    Douglas, D B

    1999-01-01

    Hypnosis is presented as a valuable and frequently neglected resource for many patients with chronic and terminal illness. Particular attention is given herein to the use of hypnosis in attaining relaxation, overcoming insomnia, helping the patient achieve pain relief, and, most particularly, teaching the patient to work with relatives and other persons close to them, as caregivers in a special relationship that can be a very important source of relief to the patient. A brief overview of indications, contraindications, errors, and safeguards is given. Sources of education and training are briefly reviewed and a bibliography is included to identify the nature of professional societies, three in the United States and one international, together with some standard publications. The purpose of this article is to affirm the value of hypnosis as a complementary or alternative therapy for hospice patients, to summarize its clinical applications, and to list the most standard and best known professional societies and publications.

  2. Homocysteine and cognitive disorders of postmenopausal women measured by a battery of computer tests--central nervous system vital signs.

    Science.gov (United States)

    Raszewski, Grzegorz; Loroch, Małgorzata; Owoc, Alfred; Łukawski, Krzysztof; Filip, Rafał; Bojar, Iwona

    2015-08-01

    The purpose of the study was the analysis of cognitive functions in postmenopausal women having different status of homocysteine levels by a battery of computer tests-central nervous system vital signs (CNS-VS). We examined whether homocysteine increases the risk of cognitive decline and which cognitive domains are more affected. We showed that the considerably better neurocognitive index was obtained by women with low homocysteine levels in comparison with those with hyperhomocysteinemia (p = 0.0017). Similarly, results were obtained in the field of executive functioning (p = 0.0011), complex attention (p = 0.0106), cognitive flexibility (p = 0.0016), and memory (p = 0.0145). Verbal memory and visual memory did not differ considerably among the studied groups. Also, we demonstrated that ε4/ε4 genotype was the most common (15.5 %) in women with hyperhomocysteinemia than in groups of patients with low (0 %) or normal (1.9 %) homocysteine levels. In summary, hyperhomocysteinemia was related with increased risk of decline in executive functioning, complex attention, cognitive flexibility, and memory in postmenopausal women.

  3. Comparing the test of practical judgment with the neuropsychological assessment battery judgment subtest in a neurodegenerative disease clinic population.

    Science.gov (United States)

    Durant, January; Berg, Jody-Lynn; Banks, Sarah Jane; Miller, Justin Benjamin

    2017-06-12

    The Test of Practical Judgment (TOP-J) and the Judgment subtest from the Neuropsychological Assessment Battery (NAB-JDG) are both brief interview-based measures that assess judgment. This study compared estimates of judgment obtained from these measures in a neurodegenerative disease population. Records from 61 referrals seen for neuropsychological evaluation in a neurodegenerative disorders clinic were reviewed. Measures of interest included the TOP-J and NAB-JDG. Concordance correlation coefficients (CCC) and root mean square differences (RMSD) were calculated between judgment T-scores. Discrepancy scores were calculated by subtracting NAB-JDG scores from TOP-J scores. CCC showed poor agreement between the judgment measures, with evidence of fixed bias, such that the NAB-JDG systematically generates higher scores than the TOP-J. This fixed bias was present whether NAB-JDG scores are demographically adjusted or unadjusted. There was no evidence of proportional bias. In a neurodegenerative disease clinic population, the TOP-J and NAB-JDG provide estimates of judgment ability that are systematically different. These two measures may be assessing different aspects within the larger construct of judgment and the inconsistency between measures would contraindicate using them interchangeably. Clinicians will need to carefully consider patient characteristics, clinical needs, and review specific item content when selecting between these measures.

  4. Haptic-2D: A new haptic test battery assessing the tactual abilities of sighted and visually impaired children and adolescents with two-dimensional raised materials.

    Science.gov (United States)

    Mazella, Anaïs; Albaret, Jean-Michel; Picard, Delphine

    2016-01-01

    To fill an important gap in the psychometric assessment of children and adolescents with impaired vision, we designed a new battery of haptic tests, called Haptic-2D, for visually impaired and sighted individuals aged five to 18 years. Unlike existing batteries, ours uses only two-dimensional raised materials that participants explore using active touch. It is composed of 11 haptic tests, measuring scanning skills, tactile discrimination skills, spatial comprehension skills, short-term tactile memory, and comprehension of tactile pictures. We administered this battery to 138 participants, half of whom were sighted (n=69), and half visually impaired (blind, n=16; low vision, n=53). Results indicated a significant main effect of age on haptic scores, but no main effect of vision or Age × Vision interaction effect. Reliability of test items was satisfactory (Cronbach's alpha, α=0.51-0.84). Convergent validity was good, as shown by a significant correlation (age partialled out) between total haptic scores and scores on the B101 test (rp=0.51, n=47). Discriminant validity was also satisfactory, as attested by a lower but still significant partial correlation between total haptic scores and the raw score on the verbal WISC (rp=0.43, n=62). Finally, test-retest reliability was good (rs=0.93, n=12; interval of one to two months). This new psychometric tool should prove useful to practitioners working with young people with impaired vision. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. A novel automated behavioral test battery assessing cognitive rigidity in two genetic mouse models of autism.

    Directory of Open Access Journals (Sweden)

    Alicja ePuścian

    2014-04-01

    Full Text Available Repetitive behaviors are a key feature of many pervasive developmental disorders, such as autism. As a heterogeneous group of symptoms, repetitive behaviors are conceptualized into two main subgroups: sensory/motor (lower-order and cognitive rigidity (higher-order. Although lower-order repetitive behaviors are measured in mouse models in several paradigms, so far there have been no high-throughput tests directly measuring cognitive rigidity. We describe a novel approach for monitoring repetitive behaviors during reversal learning in mice in the automated IntelliCage system. During the reward-motivated place preference reversal learning, designed to assess cognitive abilities of mice, visits to the previously rewarded places were recorded to measure cognitive flexibility. Thereafter, emotional flexibility was assessed by measuring conditioned fear extinction. Additionally, to look for neuronal correlates of cognitive impairments, we measured CA3-CA1 hippocampal long term potentiation (LTP. To standardize the designed tests we used C57BL/6 and BALB/c mice, representing two genetic backgrounds, for induction of autism by prenatal exposure to the sodium valproate. We found impairments of place learning related to perseveration and no LTP impairments in C57BL/6 valproate-treated mice. In contrast, BALB/c valproate-treated mice displayed severe deficits of place learning not associated with perseverative behaviors and accompanied by hippocampal LTP impairments. Alterations of cognitive flexibility observed in C57BL/6 valproate-treated mice were related to neither restricted exploration pattern nor to emotional flexibility. Altogether, we showed that the designed tests of cognitive performance and perseverative behaviors are efficient and highly replicable. Moreover, the results suggest that genetic background is crucial for the behavioral effects of prenatal valproate treatment.

  6. Digit ratio (2D:4D) and physical fitness (Eurofit test battery) in school children.

    Science.gov (United States)

    Ranson, R; Stratton, G; Taylor, S R

    2015-05-01

    The relative lengths of the index finger to the ring finger (2D:4D) is sexually dimorphic and is thought to be a correlate of prenatal sex steroids (low 2D:4D=high prenatal testosterone and low prenatal oestrogen). In adults there have been reports that low 2D:4D is consistently associated with high sports performance. To investigate correlations between 2D:4D and fitness levels in children. Right 2D:4D and body size were measured, in addition to flexibility, speed, endurance and strength (Eurofit tests). 922 boys and 835 girls (mean ages (years): 10.8 ± 1.01 and 10.07 ± 1.00 respectively). height, mass, BMI, triceps and subscapular skinfolds, 20 m shuttle run, sit and reach, standing broad jump, hand grip strength, 10 × 5m sprint, and the sit and reach test. Boys significantly outperformed the girls in the 10 × 5m sprints, the 20 m shuttle run, standing broad jump, and hand grip strength. In boys but not girls, 2D:4D was significantly negatively correlated with scores in all these tests except the standing broad jump. In girls but not boys, 2D:4D was significantly positively correlated to stature, mass, BMI and waist circumference. It is suggested that high prenatal testosterone and low prenatal oestrogen (low 2D:4D) is implicated in high sprinting speed, endurance and hand grip strength in boys. In girls low prenatal testosterone and high prenatal oestrogen is associated with large body size. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Profile of American Youth: Demographic Influences on ASVAB (Armed Services Vocational Aptitude Battery) Test Performance

    Science.gov (United States)

    1984-02-01

    well understood, but studies by Hunt (1976) and others e6em to indicate that persons who perform well in general information and verbal tests are able...tEds.), Review of Child Development Research, Vol. 3. Chicago: University of C11icago Press, 1973. 0 0 ,- -292- Hunt , E.B. Varieties of cognitive power...42, 51-158. Ramey, C.T., and Haskins, R. Early education, intellectual development, and school performance: A reply to Arthur Jensen and J. McVicker

  8. Developing a Very Low Vision Orientation and Mobility Test Battery (O&M-VLV).

    Science.gov (United States)

    Finger, Robert P; Ayton, Lauren N; Deverell, Lil; O'Hare, Fleur; McSweeney, Shane C; Luu, Chi D; Fenwick, Eva K; Keeffe, Jill E; Guymer, Robyn H; Bentley, Sharon A

    2016-09-01

    This study aimed to determine the feasibility of an assessment of vision-related orientation and mobility (O&M) tasks in persons with severe vision loss. These tasks may be used for future low vision rehabilitation clinical assessments or as outcome measures in vision restoration trials. Forty legally blind persons (mean visual acuity logMAR 2.3, or hand movements) with advanced retinitis pigmentosa participated in the Orientation & Mobility-Very Low Vision (O&M-VLV) subtests from the Low Vision Assessment of Daily Activities (LoVADA) protocol. Four categories of tasks were evaluated: route travel in three indoor hospital environments, a room orientation task (the "cafe"), a visual exploration task (the "gallery"), and a modified version of the Timed Up and Go (TUG) test, which assesses re-orientation and route travel. Spatial cognition was assessed using the Stuart Tactile Maps test. Visual acuity and visual fields were measured. A generalized linear regression model showed that a number of measures in the O&M-VLV tasks were related to residual visual function. The percentage of preferred walking speed without an aid on three travel routes was associated with visual field (p orientation, which may be of benefit in vision restoration clinical trials.

  9. School Performance and Disciplinary Problems among Abused and Neglected Children.

    Science.gov (United States)

    Eckenrode, John; And Others

    1993-01-01

    Neglected, or physically or sexually abused, children performed poorer on standardized tests, received lower grades, were more likely to repeat a grade and had more discipline referrals than nonmaltreated children. Among maltreated children, neglected children showed the poorest academic performance, and physically abused children had the most…

  10. The MuSIC perception test: a novel battery for testing music perception of cochlear implant users.

    Science.gov (United States)

    Brockmeier, S J; Fitzgerald, Denis; Searle, Oliver; Fitzgerald, Heather; Grasmeder, Mary; Hilbig, Silke; Vermiere, Katrien; Peterreins, Martin; Heydner, Susanne; Arnold, Wolfgang

    2011-02-01

    This study was undertaken to evaluate the musical sounds in cochlear implants (MuSIC) perception test, created to assess the music-listening abilities of cochlear implant (CI) users. Thirty-one unilateral MED-EL COMBI 40+/PULSARCI(100) users and a control group of 67 adults with normal hearing (NH) participated. The MuSIC test comprises six objective and two subjective modules employing approximately 2800 musical files recorded from non-synthesized instruments. A subset was used for comparing CI and NH participants' results. CI and NH participants performed significantly differently on: pitch discrimination, melody discrimination, chord discrimination, instrument detection, and instrument identification. No significant difference in performance was seen on the subtests of rhythm discrimination or dissonance rating and emotion rating. The MuSIC test was found to be a valuable tool for assessing music perception in CI users and NH participants, whether investigating one aspect of music perception in depth or conducting a broad survey of music perception.

  11. Gender differences in performance of the Movement Assessment Battery for Children - 2nd edition test in adolescents

    Directory of Open Access Journals (Sweden)

    Valtr Ludvík

    2016-12-01

    Full Text Available Background: The Movement Assessment Battery for Children - 2nd edition (MABC-2 is used for the assessment of motor proficiency and identification of motor impairments in 3-16 year old children. Although there are some gender differences in the motor development of children, in the MABC-2 test the same tasks and norms are used for both genders. Objective: The aim of the study was to determine gender differences in performance of motor tasks involved in the MABC-2 test in adolescents aged 15 to 16. Methods: Participants (N = 121, 50 boys and 71 girls, mean age 16.0 ± 0.5 years randomly recruited from schools were assessed using the MABC-2 test. The Mann-Whitney U test and effect size r were used to analyse gender differences in performance outcome in the particular motor tasks of the MABC-2 test. Results: As compared to the boys, the girls achieved a significantly shorter time of completion of the unimanual coordination task executed with their preferred hand (p < .001, r = .33 and significantly fewer errors in the graphomotor task (p = .001, r = .29. On the other hand, the boys achieved significantly better results than the girls in the aiming and catching tasks (p ≤ .030, r = .20-.33. Performance in the dynamic balance tasks was not significantly different between genders. The girls demonstrated a significantly longer duration of static balance in one-leg standing as compared to the boys (p = .011, r = .23. For the motor tasks some statistical differences were found, however the effect size of the gender on performance was small or medium. Conclusions: The findings of the study suggest that gender could be a significant factor of performance in the motor tasks associated with object control such as aiming and catching. Other domains, such as manual dexterity and balance, seem to be influenced by gender to a small extent.

  12. Technical feasibility for commercialization of lithium ion battery as a substitute dry battery for motorcycle

    Science.gov (United States)

    Kurniyati, Indah; Sutopo, Wahyudi; Zakaria, Roni; Kadir, Evizal Abdul

    2017-11-01

    Dry battery on a motorcycle has a rapid rate of voltage drop, life time is not too long, and a long charging time. These are problems for users of dry battery for motorcycle. When the rate in the voltage decreases, the energy storage in the battery is reduced, then at the age of one to two years of battery will be dead and cannot be used, it makes the user should replace the battery. New technology development of a motorcycle battery is lithium ion battery. Lithium ion battery has a specification that has been tested and possible to replace dry battery. Characteristics of lithium ion battery can answer the question on the dry battery service life, the rate of decrease in voltage and charging time. This paper discusses about the technical feasibility for commercialization of lithium ion battery for motorcycle battery. Our proposed methodology of technical feasibility by using a goldsmith commercialization model of the technical feasibility and reconfirm the technical standard using the national standard of motorcycle battery. The battery has been through all the stages of the technical feasibility of the goldsmith model. Based on the results of the study, lithium ion batteries have the minimum technical requirements to be commercialized and has been confirmed in accordance with the standard motorcycle battery. This paper results that the lithium ion battery is visible to commercialized by the technical aspect.

  13. A systematic review to determine reliability and usefulness of the field-based test batteries for the assessment of physical fitness in adolescents – The ASSO Project

    Directory of Open Access Journals (Sweden)

    Antonino Bianco

    2015-06-01

    Full Text Available The aim of the present review is to investigate the main field-based tests, used alone or included in sport or fitness batteries, for the assessment of health- and skill-related physical fitness components in adolescents. Different scientific databases were searched through using the selected key words related to physical fitness and its components for adolescence. The search focused on original articles and reviews/meta-analyses using valid, reproducible and feasible tests that fit within the school environment. A total of 100 scientific manuscripts were included in the qualitative synthesis. The present systematic review pointed out 5 fitness tests that well adapt to the evaluation of the components of physical fitness of adolescents within a school environment: the 20 m shuttle run test for cardio-respiratory endurance; the handgrip strength test for upper body maximal strength; the standing broad jump test for lower body maximal strength; the sit-up test to exhaustion for muscular endurance and the 4×10 m shuttle run test for speed, agility and coordination. These fitness tests have been finally selected and incorporated into the Adolescents and Surveillance System for the Obesity prevention – Fitness Test Battery (ASSO-FTB, and will be adopted within the ASSO Project for evaluation purposes. This instrument could be also provided to teachers and people working in schools in order to assess physical fitness of adolescents over time and prevent obesity and related diseases.

  14. A note on neglect defaulting

    Directory of Open Access Journals (Sweden)

    Howard Margolis

    2008-04-01

    Full Text Available I introduce the notion of ``neglect defaulting,'' which labels the propensity to neglect possibilities which are ordinarily sensibly neglected. In familiar contexts we are well-tuned to recognize when to override the default. But outside the range of familiar experience --- here in the artificial context of puzzles --- these ordinarily benign defaults can make it difficult for even sophisticated subjects, such as readers of this note, to avoid responses which on reflection will be seen as obviously mistaken. A detail of particular importance is that, although subjects are easily prompted to take one step in the direction of reaching a sound response, the tendency to then neglect to consider that another step may be needed is remarkably strong. In each of the five examples the needed but usually neglected second step is quite trivial. Concluding remarks point to consequences for larger questions outside the range of familiar experience, in politics and other contexts out of scale with everyday experience.

  15. Neglected and endemic zoonoses.

    Science.gov (United States)

    Maudlin, Ian; Eisler, Mark Charles; Welburn, Susan Christina

    2009-09-27

    Endemic zoonoses are found throughout the developing world, wherever people live in close proximity to their animals, affecting not only the health of poor people but often also their livelihoods through the health of their livestock. Unlike newly emerging zoonoses that attract the attention of the developed world, these endemic zoonoses are by comparison neglected. This is, in part, a consequence of under-reporting, resulting in underestimation of their global burden, which in turn artificially downgrades their importance in the eyes of administrators and funding agencies. The development of cheap and effective vaccines is no guarantee that these endemic diseases will be eliminated in the near future. However, simply increasing awareness about their causes and how they may be prevented-often with very simple technologies-could reduce the incidence of many endemic zoonoses. Sustainable control of zoonoses is reliant on surveillance, but, as with other public-sector animal health services, this is rarely implemented in the developing world, not least because of the lack of sufficiently cheap diagnostics. Public-private partnerships have already provided advocacy for human disease control and could be equally effective in addressing endemic zoonoses.

  16. Neglected hangman fracture

    Directory of Open Access Journals (Sweden)

    Sudhir Kumar Srivastava

    2015-01-01

    Full Text Available Acute management of hangman fracture is well described; however the surgical management of neglected hangman fracture has not been described in literature. We report the surgical management of an untreated hangman′s fracture. A 30-year-old male had fallen from a tree 12 weeks back. Patient presented with cervical myelopathy and restricted neck movements. Radiographs and computed tomography (CT scan revealed fracture of pars interarticularis of axis with Grade III C2-C3 spondylolisthesis with localized kyphosis of 33°. Gentle reduction under general anesthesia (GA failed to improve the alignment. Patient was operated in three stages in a single setting. In Stage I, release of contracted anterior structures and C2-C3 discectomy was done in supine position followed by C2-C3 posterior fixation and fusion in Stage II. C2-C3 interbody bone grafting and anterior plating completed the third stage. C2-C3 interbody fusion was seen at 5 months and a CT scan at 18 months postoperative confirmed fusion and maintenance of alignment. The satisfactory outcome in our patient leads us to believe that anterior-posterior-anterior is the appropriate surgical approach for treatment of such patients.

  17. Initial Operational Test and Evaluation (IOT&E) of ASVAB (Armed Services Vocational Aptitude Battery) Forms 11, 12, and 13: Parallelism of the New Forms. Volume 1

    Science.gov (United States)

    1988-07-01

    AFHRL-TR-87-65( I) INITIAL OPERATIONAL TEST AND EVALUATIONI R FO RC E ( IOT &E) OF ASVAB FORMS 11, 12, AND 13:PARALLELISM OF THE NEW FORMS l 3 :Q In H...UNfT B A c ELEMENT NO NO NO ACCESSION NO 62703F 7719 18 42 I1. TITLE (Include Security Cltasficaton) Initial Operational Test and Evaluation ( IOT &E...of the Initial Operational Test and Evaluation ( IOT &E) of Forms ]a, lib, 12a, 12b, 13a, and 13b of the Armed Services Vocational Aptitude Battery

  18. Crystallization of aluminum hydroxide in the aluminum-air battery: Literature review, crystallizer design and results of integrated system tests

    Science.gov (United States)

    Maimoni, A.

    1988-03-01

    The literature on aluminum trihydroxide crystallization is reviewed and the implications of crystallization on the design and performance of the aluminum-air battery are illustrated. Results of research on hydrargillite crystallization under battery operating conditions at Alcoa Laboratories, Alcan Kingston Laboratories, and Lawrence Livermore National Laboratory are summarized and are applied to the design of an electrolyte management system using lamella settlers for clarification of the electrolyte and product separation. The design principles were validated in a series of experiments that, for the first time in the aluminum-air program, demonstrated continuous operation of an integrated system consisting of cells, crystallizer, and a product-removal system.

  19. Development of an auditory situation awareness test battery for advanced hearing protectors and TCAPS: detection subtest of DRILCOM (detection-recognition/identification-localization-communication).

    Science.gov (United States)

    Lee, Kichol; Casali, John G

    2017-01-01

    To design a test battery and conduct a proof-of-concept experiment of a test method that can be used to measure the detection performance afforded by military advanced hearing protection devices (HPDs) and tactical communication and protective systems (TCAPS). The detection test was conducted with each of the four loudspeakers located at front, right, rear and left of the participant. Participants wore 2 in-ear-type TCAPS, 1 earmuff-type TCAPS, a passive Combat Arms Earplug in its "open" or pass-through setting and an EB-15LE™ electronic earplug. Devices with electronic gain systems were tested under two gain settings: "unity" and "max". Testing without any device (open ear) was conducted as a control. Ten participants with audiometric requirements of 25 dBHL or better at 500, 1000, 2000, 4000, 8000 Hz in both ears. Detection task performance varied with different signals and speaker locations. The test identified performance differences among certain TCAPS and protectors, and the open ear. A computer-controlled detection subtest of the Detection-Recognition/Identification-Localisation-Communication (DRILCOM) test battery was designed and implemented. Tested in a proof-of-concept experiment, it showed statistically-significant sensitivity to device differences in detection effects with the small sample of participants (10). This result has important implications for selection and deployment of TCAPS and HPDs on soldiers and workers in dynamic situations.

  20. Validation of Battery Safety for Space Missions

    Science.gov (United States)

    Jeevarajan, Judith

    2012-01-01

    Presentation covers: (1) Safety Certification Process at NASA (2) Safety Testing for Lithium-ion Batteries (3) Limitations Observed with Li-ion Batteries in High Voltage and High Capacity Configurations.

  1. Test of hybrid power system for electrical vehicles using a lithium-ion battery pack and a reformed methanol fuel cell range extender

    DEFF Research Database (Denmark)

    Andreasen, Søren Juhl; Ashworth, Leanne; Sahlin, Simon Lennart

    2014-01-01

    This work presents the proof-of-concept of an electric traction power system with a high temperature polymer electrolyte membrane fuel cell range extender, usable for automotive class electrical vehicles. The hybrid system concept examined, consists of a power system where the primary power...... is delivered by a lithium ion battery pack. In order to increase the run time of the application connected to this battery pack, a high temperature PEM (HTPEM) fuel cell stack acts as an on-board charger able to charge a vehicle during operation as a series hybrid. Because of the high tolerance to carbon...... monoxide, the HTPEM fuel cell system can efficiently use a liquid methanol/water mixture of 60%/40% by volume, as fuel instead of compressed hydrogen, enabling potentially a higher volumetric energy density. In order to test the performance of such a system, the experimental validation conducted uses...

  2. National Field Testing of the "Mini" Version of the Transition Competence Battery for Adolescents and Young Adults Who Are Deaf.

    Science.gov (United States)

    Bullis, Michael; Reiman, John W.; Davis, Cheryl; Reid, Chris

    1997-01-01

    A study involving 593 students (ages 15-29) with deafness investigated the validity of a shortened version of the Transition Competence Battery for Deaf Adolescents and Young Adults (TCB). Overall results suggest that the "Mini" TCB is a viable assessment tool that can be used in transition assessment. (Author/CR)

  3. Quality Control of Lead-Acid Battery according to Its Condition Test for UPS Supplier and Manufacturers

    Directory of Open Access Journals (Sweden)

    Tsung-Chih Hsiao

    2014-01-01

    Full Text Available The risk of insufficient petroleum resources has forced human beings to emphasize the acquisition and storage of energy. To avoid such situation, this study tends to explore the effective management of lead-acid batteries for effective utilization conforming to the industrial requirements.

  4. Practical Methods in Li-ion Batteries

    DEFF Research Database (Denmark)

    Barreras, Jorge Varela

    This thesis presents, as a collection of papers, practical methods in Li-ion batteries for simplified modeling (Manuscript I and II), battery electric vehicle design (III), battery management system testing (IV and V) and balancing system control (VI and VII). • Manuscript I tackles methodologies...... to parameterize battery models based solely on manufacturer’s datasheets • Manuscript II presents a parameterization method for battery models based on the notion of direct current resistance • Manuscript III proposes a battery electric vehicle design that combines fixed and swappable packs • Manuscript IV...... develops a battery system model for battery management system testing on a hardware-in-the-loop simulator • Manuscript V extends the previous work, introducing theoretical principles and presenting a practical method to develop ad hoc software and strategies for testing • Manuscript VI presents...

  5. Disentangling input and output-related components of spatial neglect

    Science.gov (United States)

    Loetscher, Tobias; Nicholls, Michael E. R.; Brodtmann, Amy; Thomas, Nicole A.; Brugger, Peter

    2012-01-01

    Spatial neglect is a heterogeneous disorder with a multitude of manifestations and subtypes. Common clinical paper and pencil neglect tests fail to differentiate between these subtypes. For example, neglect patients typically bisect lines to the right. This bias can be caused by an underestimation of the left half of the line (input-related deficit), by the failure to direct actions toward the left side of space (output-related deficit), or by a mixture of these impairments. To disentangle these impairments, we used a test consisting of a line bisection task on a touch screen monitor (manual motor task) and the subsequent judgment of one's own bisection performance (visual perceptual task). It was hypothesized that patients with mainly output-related neglect should be better able to recognize their misbisected lines than patients with purely input-related neglect. In a group of 16 patients suffering from spatial neglect after right brain damage, we found that patients were three times more likely to suffer from a predominantly input-related than from an output-related subtype. The results thus suggest that neglect is typically an input-related impairment. Additional analysis of the line bisection task revealed that temporal (slowness in initiation and execution of contralateral movements) and spatial (insufficient movement amplitude toward the contralesional side) aspects of output-related neglect were mutually unrelated. This independence raises the possibility that a fine-grained differentiation of output-related neglect is required. That is, impairments in lateralized temporal and spatial aspects of movements may underlie different neglect subtypes. PMID:22707937

  6. Neural correlates of somatosensory processing in patients with neglect.

    Science.gov (United States)

    Hassa, Thomas; Schoenfeld, Mircea Ariel; Dettmers, Christian; Stoppel, Christian Michael; Weiller, Cornelius; Lange, Rüdiger

    2011-01-01

    Recent evidence from neuroimaging studies using visual tasks suggests that the right superior parietal cortex plays a pivotal role for the recovery of neglect. Importantly, neglect-related deficits are not limited to the visual system and have a rather multimodal nature. We employed somatosensory stimulation in patients with neglect in order to analyze activity changes in networks that are presumably associated with this condition. Eleven chronic neglect patients with right hemispherical stroke were investigated with a fMRI paradigm in which the affected and unaffected hand were passively moved. Brain activation was correlated with the performance in clinical neglect tests. Significant positive correlations with brain activation were found for the lesion duration, the performance in bells and letter cancellation tests and the line bisection test. These activated areas formed a distributed pattern in the right superior parietal cortex. The results suggest a shared representation of visual and somatosensory networks in the right superior parietal cortex in patients with right hemispherical strokes and neglect. The spatial pattern of activity in the superior parietal cortex points out to a different representation of changes related to lesion duration and neglect.

  7. Button batteries

    Science.gov (United States)

    ... recovery. Alternative Names Swallowing batteries References Hess JM, Lowell MJ. Esophagus, stomach and duodenum. In: Marx JA, ... Jacob L. Heller, MD, MHA, Emergency Medicine, Virginia Mason Medical Center, Seattle, WA. Also reviewed by David ...

  8. Transmission of Neglect in Substance Abuse Families: The Role of Child Dysregulation and Parental SUD.

    Science.gov (United States)

    Dunn, Marija G.; Mezzich, Ada; Janiszewski, Susan; Kirisci, Levent; Tarter, Ralph E.

    2001-01-01

    Paternal and maternal models of transmission of child neglect were tested separately in offspring of men with a substance use disorder (SUD). Child dysregulation was independently related to neglect severity. SUD in the mother directly correlated with severity of neglectful parenting. (Contains 51 references and 2 tables.) (GCP)

  9. Woodcock-Johnson-III, Kaufman Adolescent and Adult Intelligence Test (KAIT), Kaufman Assessment Battery for Children (KABC), and Differential Ability Scales (DAS) support Carroll but not Cattell-Horn.

    Science.gov (United States)

    Cucina, Jeffrey M; Howardson, Garett N

    2017-08-01

    Recently emerging evidence suggests that the dominant structural model of mental abilities-the Cattell-Horn-Carroll (CHC) model-may not adequately account for observed scores for mental abilities batteries, leading scholars to call into question the model's validity. Establishing the robustness of these findings is important since CHC is the foundation for several contemporary mental abilities test batteries, such as the Woodcock-Johnson III (WJ-III). Using confirmatory factor analysis, we investigated CHC's robustness across 4 archival samples of mental abilities test battery data, including the WJ-III, the Kaufman Adolescent & Adult Intelligence Test (KAIT), the Kaufman Assessment Battery for Children (KABC), and the Differential Ability Scales (DAS). We computed omega hierarchical (ωH) and omega subscale (ωS) coefficients for g and the broad factors, which estimated the relationship of composite scores to g and the broad factors, respectively. Across all 4 samples, we found strong evidence for a general ability, g. We additionally found evidence for 3 to 9 residualized, orthogonal broad abilities existing independently of g, many of which also explained reliable variance in test battery scores that cannot be accounted for by g alone. The reliabilities of these broad factors, however, were less than desirable (i.e., mental abilities test battery scores, which is consistent with Carroll but not Cattell-Horn. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Development of a Physical Employment Testing Battery for Infantry Soldiers: 11B Infantryman and 11C Infantryman - Indirect Fire

    Science.gov (United States)

    2015-12-01

    observed the Soldiers. Quantifiable task details were recorded, including quantity and weights of loads being moved or lifted, distances traveled ...battery (11), Soldiers also performed the task once solo , with the bag weighted at 103.5 lb. Army Standard: Casualty removed from vehicle in 2...than males for the carry phase of a fighting position. Of the strength tasks, females took longer to complete the casualty drag, solo casualty

  11. Average Behavior of Battery - Electric Vehicles for Distributed Energy System Studies

    DEFF Research Database (Denmark)

    Marra, Francesco; Træholt, Chresten; Larsen, Esben

    2010-01-01

    use conditions cannot be neglected for a proper estimation of available fleet energy. In this paper we describe an average behavior of battery-EVs. Main points of this concept include the definition of the energy window and lifetime of the batteries, in relation to existing models and battery use......The increase of focus on electric vehicles (EVs) as distributed energy resources calls for new concepts of aggregated models of batteries. Despite the developed battery models for EVs applications, when looking at energy storage scenarios using EVs, both geographical-temporal aspects and battery...

  12. Development of a test battery (NPM-X) for neuropsychological and neuromotor examination of children with developmental disabilities or mental retardation. A theoretical and clinical study.

    Science.gov (United States)

    Gjaerum, B

    1997-01-01

    Biological and behavioural diagnosis often do not provide information on functional competence. This is, however, of utmost importance in planning services as well as in research on treatment effects for children with developmental disorders. For school-aged children neuropsychological assessment has proved its value in this respect. For children of chronological age (CA) below 5-7 with specific developmental disabilities, and for children with severe mental retardation there has been a lack of applicable test batteries. This thesis presents a new test battery for neuropsychological and neuromotor examination, NPM-X, for these two groups of children. The first part of the thesis reviews available medical and psychological tests and assessment procedures with respect to applicability and relevance for neuropsychological assessment to children with mental retardation and mental age (MA) below 7. The second part describes the theoretical background and the content of the new test battery. The methodology for testing these children, who due to their age and/or their developmental disabilities often co-operate poorly, is described. Scoring categories, specifically developed to enable a detailed and differentiated description of the child, are presented. Because of the instability of the behavioural function in early age as well as in cases of severe disability, the scoring system records both the child's optimal functional capacity and inconsistencies in behaviour. For the purpose of planning treatment and training according to the child's resources as well as dysfunctions, two different functional profiles are provided. In the normative functional profile the child's functional level is compared to normal expectations for the child's CA, and in the ideographic functional profile the child's function in each area is compared to the child's average functional level. In the third part of the thesis the reliability results are presented and discussed. A pair of trained M

  13. Harnessing motivation to alleviate neglect

    Directory of Open Access Journals (Sweden)

    Charlotte eRussell

    2013-06-01

    Full Text Available The syndrome of spatial neglect results from the combination of a number of deficits in attention, with patients demonstrating both spatially lateralised and non-lateralised impairments. Previous reports have hinted that there may be a motivational component to neglect and that modulating this might alleviate some of the debilitating symptoms. Additionally, recent work on the effects of reward on attention in healthy participants has revealed improvements across a number of paradigms. As the primary deficit in neglect has been associated with attention, this evidence for reward’s effects is potentially important. However, until very recently there have been few empirical studies addressing this potential therapeutic avenue. Here we review the growing body of evidence that attentional impairments in neglect can be reduced by motivation, for example in the form of preferred music or anticipated monetary reward, and discuss the implications of this for treatments for these patients. Crucially these effects of positive motivation are not observed in all patients with neglect, suggesting that the consequences of motivation may relate to individual lesion anatomy. Given the key role of dopaminergic systems in motivational processes, we suggest that motivational stimulation might act as a surrogate for dopaminergic stimulation. In addition, we consider the relationship between clinical post stroke apathy and lack of response to motivation.

  14. FOOD NEGLECT AND INFANT DEVELOPMENT.

    Science.gov (United States)

    Helton, Jesse J; Cross, Theodore P; Vaughn, Michael G; Gochez-Kerr, Tatiana

    2018-03-01

    The impact of food insecurity on child development in the general U.S. population is well-established, yet little is known about the harm of food neglect relative to other types of maltreatment. Due to the harmful physiological impact of inadequate nutrients and the social impact of food-related stress, it was hypothesized that food neglect would be more likely to impair infant cognitive and language development than physical abuse, sexual abuse, and other forms of neglect. Families of infants (N = 1,951) investigated by Child Protective Services were studied using the second cohort of the National Survey of Child and Adolescent Well-Being (NSCAW II; NSCAW Research Group, 2002). Results from multivariable logistic regression models that controlled for likely confounding variables showed that the odds of impairment in cognition and language were significantly greater when food neglect was the most serious form of maltreatment. Considering that both food insecurity and child neglect are associated with poverty and parental mental health problems, it will be important for child welfare and mental health professionals to work collaboratively to better the health of these vulnerable children. © 2018 Michigan Association for Infant Mental Health.

  15. Neglect Patients Exhibit Egocentric or Allocentric Neglect for the Same Stimulus Contingent upon Task Demands

    OpenAIRE

    Leyland, Louise-Ann; Godwin, Hayward J.; Benson, Valerie; Liversedge, Simon P.

    2017-01-01

    Hemispatial Neglect (HN) is a failure to allocate attention to a region of space opposite to where damage has occurred in the brain, usually the left side of space. It is widely documented that there are two types of neglect: egocentric neglect (neglect of information falling on the individual's left side) and allocentric neglect (neglect of the left side of each object, regardless of the position of that object in relation to the individual). We set out to address whether neglect presentatio...

  16. De behandeling van neglect, een aandachtstoornis

    NARCIS (Netherlands)

    Ten Brink, A. F.|info:eu-repo/dai/nl/413640248; Nijboer, Tanja C W|info:eu-repo/dai/nl/304832421; Visser-Meily, J. M A|info:eu-repo/dai/nl/180428047

    2017-01-01

    Neglect occurs in 30-50% of patients in the subacute phase post-stroke. Patients with neglect ignore one side of their body or one part of the space around them. Treatment of neglect is important, as patients with neglect recover more slowly and are less independent compared to patients without

  17. Pharmacological evaluation of novel 5-HT3 receptor antagonist, QCM-13 (N-cyclohexyl-3-methoxyquinoxalin-2-carboxamide) as anti-anxiety agent in behavioral test battery.

    Science.gov (United States)

    Gupta, Deepali; Radhakrishnan, Mahesh; Thangaraj, Devadoss; Kurhe, Yeshwant

    2015-01-01

    In the last few decades, serotonin type-3 (5-HT3) receptor antagonists have been identified as potential targets for anxiety disorders. In preclinical studies, 5-HT3 antagonists have shown promising antianxiety effects. In this study, a novel 5-HT3 receptor antagonist, QCM-13(N-cyclohexyl-3-methoxyquinoxalin-2-carboxamide) was evaluated for anxiolytic-like activity in rodent behavioral test battery. Mice were given QCM-13 (2 and 4 mg/kg, intraperitoneally [i.p.]) or diazepam (2 mg/kg, i.p.) or vehicle and after 30 min, mice were subjected to four validated behavioral test batteries viz. elevated plus maze, hole board, light-dark and open field tests. Interaction study of QCM-13 with m-chlorophenyl piperazine (mCPP) (mCPP, a 5-HT2A/2C receptor agonist, 1 mg/kg, i.p.) and buspirone (BUS, a partial 5-HT1A agonist, 10 mg/kg, i.p.) were performed to assess the pharmacological mechanism of the drug. QCM-13 expressed potential anxiolytic effect with significant (P QCM-13 was unable to reverse the anxiogenic effect of mCPP, but potentiated anxiolytic affect of BUS. The results suggest that QCM-13 can be a potential therapeutic candidate for the management of anxiety-like disorders and combination doses of novel 5-HT3 receptor antagonist with standard anxiolytics may improve therapeutic efficacy.

  18. Advanced battery development

    Science.gov (United States)

    In order to promote national security by ensuring that the United States has an adequate supply of safe, assured, affordable, and environmentally acceptable energy, the Storage Batteries Division at Sandia National Laboratories (SNL), Albuquerque, is responsible for engineering development of advanced rechargeable batteries for energy applications. This effort is conducted within the Exploratory Battery Technology Development and Testing (ETD) Lead center, whose activities are coordinated by staff within the Storage Batteries Division. The ETD Project, directed by SNL, is supported by the U.S. Department of Energy, Office of Energy Systems Research, Energy Storage and Distribution Division (DOE/OESD). SNL is also responsible for technical management of the Electric Vehicle Advanced Battery Systems (EV-ABS) Development Project, which is supported by the U.S. Department of Energy's Office of Transportation Systems (OTS). The ETD Project is operated in conjunction with the Technology Base Research (TBR) Project, which is under the direction of Lawrence Berkeley Laboratory. Together these two projects seek to establish the scientific feasibility of advanced electrochemical energy storage systems, and conduct the initial engineering development on systems suitable for mobile and stationary commercial applications.

  19. Neglecting the left side of a city square but not the left side of its clock: prevalence and characteristics of representational neglect.

    Directory of Open Access Journals (Sweden)

    Cecilia Guariglia

    Full Text Available Representational neglect, which is characterized by the failure to report left-sided details of a mental image from memory, can occur after a right hemisphere lesion. In this study, we set out to verify the hypothesis that two distinct forms of representational neglect exist, one involving object representation and the other environmental representation. As representational neglect is considered rare, we also evaluated the prevalence and frequency of its association with perceptual neglect. We submitted a group of 96 unselected, consecutive, chronic, right brain-damaged patients to an extensive neuropsychological evaluation that included two representational neglect tests: the Familiar Square Description Test and the O'Clock Test. Representational neglect, as well as perceptual neglect, was present in about one-third of the sample. Most patients neglected the left side of imagined familiar squares but not the left side of imagined clocks. The present data show that representational neglect is not a rare disorder and also support the hypothesis that two different types of mental representations (i.e. topological and non-topological images may be selectively damaged in representational neglect.

  20. Neglected locked vertical patellar dislocation

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Gupta

    2012-01-01

    Full Text Available Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge.

  1. Casing Tier 529.887-020; Sausage Packer; Skin Peeler 525.884-050; Sliced-Bacon Packer II; Packer 920.887-114 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  2. Manager, Retail Automotive Service (ret. tr.) 0-72.12; Proprietor-Manager, Retail Automotive Service (ret. tr.)--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  3. Gasoline-Engine Assembler (engine & turbine) 806.781; Internal-Combustion-Engine-Assembler (engine & turbine) 806.781; Outboard-Motor Assembler (engine & turbine) 806.781--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  4. Substation Operator (light, heat & power) 952.782-042; Switchboard Operator (light, heat, & power) 952.782-050; Turbine Operator (light, heat & power) 9-52.782-062--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  5. Strongyloidiasis--the most neglected of the neglected tropical diseases?

    DEFF Research Database (Denmark)

    Olsen, A.; L., van Lieshout; Marti, H.

    2009-01-01

    in relation to diagnostic methods for detecting the infection, the morbidity caused by the infection and the recommended treatment. It further discusses some of the reasons why this infection is so neglected and the consequence of this for the estimated global prevalence. The paper finally points to the gaps...

  6. Informatics for neglected diseases collaborations.

    Science.gov (United States)

    Bost, Frederic; Jacobs, Robert T; Kowalczyk, Paul

    2010-05-01

    Many different public and private organizations from across the globe are collaborating on neglected diseases drug-discovery and development projects with the aim of identifying a cure for tropical infectious diseases. These neglected diseases collaborations require a global, secure, multi-organization data-management solution, combined with a platform that facilitates communication and supports collaborative work. This review discusses the solutions offered by 'Software as a Service' (SaaS) web-based platforms, despite notable challenges, and the evolution of these platforms required to foster efficient virtual research efforts by geographically dispersed scientists.

  7. Vaccines to combat the neglected tropical diseases

    Science.gov (United States)

    Bethony, Jeffrey M.; Cole, Rhea N.; Guo, Xiaoti; Kamhawi, Shaden; Lightowlers, Marshall W.; Loukas, Alex; Petri, William; Reed, Steven; Valenzuela, Jesus G.; Hotez, Peter J.

    2012-01-01

    Summary The neglected tropical diseases (NTDs) represent a group of parasitic and related infectious diseases such as amebiasis, Chagas disease, cysticercosis, echinococcosis, hookworm, leishmaniasis, and schistosomiasis. Together, these conditions are considered the most common infections in low- and middle-income countries, where they produce a level of global disability and human suffering equivalent to better known conditions such as human immunodeficiency virus/acquired immunodeficiency syndrome and malaria. Despite their global public health importance, progress on developing vaccines for NTD pathogens has lagged because of some key technical hurdles and the fact that these infections occur almost exclusively in the world’s poorest people living below the World Bank poverty line. In the absence of financial incentives for new products, the multinational pharmaceutical companies have not embarked on substantive research and development programs for the neglected tropical disease vaccines. Here, we review the current status of scientific and technical progress in the development of new neglected tropical disease vaccines, highlighting the successes that have been achieved (cysticercosis and echinococcosis) and identifying the challenges and opportunities for development of new vaccines for NTDs. Also highlighted are the contributions being made by non-profit product development partnerships that are working to overcome some of the economic challenges in vaccine manufacture, clinical testing, and global access. PMID:21198676

  8. Assessment of cognition using the Rao's Brief Repeatable Battery of Neuropsychological Tests on a group of Brazilian patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Joseph Bruno Bidin Brooks

    2011-12-01

    Full Text Available To assess the cognition of patients with multiple sclerosis (MS using the Rao's Brief Repeatable Battery of Neuropsychological Tests (BRB-N. METHOD: BRB-N was translated and adapted for control subjects. Subsequently, it was applied to a group of patients with relapsing-remitting (RR MS. RESULTS: The assessment on the healthy controls (n=47 showed that the correlation between tests on the same cognitive domain was high and that there was a five-factor solution that explained 90% of the total variance. Except for the Word List Generation subset of tests, the performance of patients with RRMS (n=39 was worse than that of the healthy controls. CONCLUSION: BRB-N is a relatively simple method to assess cognition of patients with MS in the daily clinic. It does not take long to apply and does not require special skills or equipment.

  9. Evaluation methods and assistance in the interpreting complex toxicity data using an ecotoxicological battery of tests; Toxizitaetsdaten aus einer oekotoxikologischen Testbatterie. Auswertemethode und Interpretationshilfe

    Energy Technology Data Exchange (ETDEWEB)

    Neumann-Hensel, H. [Dr. Fintelmann und Dr. Meyer Handels- und Umweltschutzlaboratorien, Hamburg (Germany); Pudenz, S. [Criterion - Bewertung und Informationsmanagement, Berlin (Germany)

    2003-07-01

    The influence of industrial chemicals in the environment is strongly determined by the condition of the soil. Considering the complex interrelationships of soil condition and the specific parameters of the material as influential to bioavailability and decompositional reactions, it is necessary to reproduce various situations via a selected battery of ecotoxicological tests. The use of such batteries has already proved to be suitable for the examination of sediments. In order to make statements about the dangerous potential of chemicals in the soil, samples of natural soil were exposed to industrial chemicals (surfactants, mineral oil hydrocarbons, an antibiotic and a pesticide), and examined regularly in test batteries over a period of four weeks. This microcosm works as a degradation test of environmental relevance, monitoring the effects and reactions of industrial chemicals in natural soil. All test results collected over this period of time come to a very complex and multi-dimensional compilation of data which needs to be considered in full before an assessment is possible. The main goal in analysing the data is to extract the maximum possible information from the matrix. Aside from the graphic presentation, mathematic graphs of the data will be introduced. This method aims to provide a structural and logical relationship to the data, in order to build up a classification system and an order of precedence, which should make it possible to estimate potential risk. (orig.) [German] Das Verhalten von Industriechemikalien in der Umwelt wird durch das Kompartiment Boden stark beeinflusst. Vor dem Hintergrund der komplexen Verflechtung der Bodeneigenschaften und der stoffspezifischen Parameter als Einflussgroesse der Bioverfuegbarkeit und des Abbauverhaltens ist es erforderlich, verschiedene Expostionssituationen mit Hilfe von ausgewaehlten oekotoxikologischen Tests abzubilden. Dazu wurde eine Testkombination eingesetzt, die sich bereits zur Untersuchung von

  10. Battery selection for space experiments

    Science.gov (United States)

    Francisco, David R.

    1992-10-01

    This paper will delineate the criteria required for the selection of batteries as a power source for space experiments. Four basic types of batteries will be explored, lead acid, silver zinc, alkaline manganese and nickel cadmium. A detailed description of the lead acid and silver zinc cells while a brief exploration of the alkaline manganese and nickel cadmium will be given. The factors involved in battery selection such as packaging, energy density, discharge voltage regulation, and cost will be thoroughly examined. The pros and cons of each battery type will be explored. Actual laboratory test data acquired for the lead acid and silver zinc cell will be discussed. This data will include discharging under various temperature conditions, after three months of storage and with different types of loads. A description of the required maintenance for each type of battery will be investigated. The lifetime and number of charge/discharge cycles will be discussed.

  11. Performance of Automotive SLI Battery under Constant Current ...

    African Journals Online (AJOL)

    In this project, a cost-effective 12V battery charge controller was developed to implement constant current constant voltage charge algorithm in small-sized stand-alone solar PV systems. The algorithm was tested on automotive SLI battery instead of deep-cycle PV battery to further reduce overall system cost. The battery ...

  12. Development of an in vitro test battery for assessing chemical effects on bovine germ cells under the ReProTect umbrella

    International Nuclear Information System (INIS)

    Lazzari, Giovanna; Tessaro, Irene; Crotti, Gabriella; Galli, Cesare; Hoffmann, Sebastian; Bremer, Susanne; Pellizzer, Cristian

    2008-01-01

    Current European legislation for the registration and authorisation of chemicals (REACH) will require a dramatic increase in the use of animals for reproductive toxicity testing. Since one objective of REACH is to use vertebrates only as last resort, the development and validation of alternative methods is urgently needed. For this purpose ReProTect, an integrated research project funded by the European Union, joining together 33 partners with complementary expertise in reproductive toxicology, was designed. The study presented here describes a battery of two tests developed within ReProTect. The objective of these tests is the detection of chemical effects during the processes of oocyte maturation and fertilisation in a bovine model. The corresponding toxicological endpoints are the reaching of metaphase II and the formation of the pronuclei respectively. Fifteen chemicals have been tested (Benzo[a]pyrene, Busulfan, Butylparaben, Cadmium Chloride, Carbendazim, Cycloheximide, Diethylstilbestrol, Genistein, Ionomycin, Ketoconazole, Lindane, Methylacetoacetate, Mifepristone, Nocodazole and DMSO as solvent) demonstrating high intra-laboratory reproducibility of the tests. Furthermore, the responses obtained in both tests, for several substances, had a good correlation with the available in vivo and in vitro data. These tests therefore, could predictably become part of an integrated testing strategy that combines the bovine models with additional in vitro tests, in order to predict chemical hazards on mammalian fertility

  13. Be careful for neglected diseases

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... INTRODUCTION. According to a piece of Nature news, many neglected diseases boost especially in tropical regions (Butler,. 2009a, b). In my opinion, it is the inherent result of ... (2009) pointed out that bamboo is one of best candidates ... When Equation (1) is used for brain cells, fifth dimension of life can ...

  14. Walking trajectory in neglect patients

    NARCIS (Netherlands)

    Huitema, RB; Brouwer, WH; Hof, AL; Dekker, R; Mulder, T; Postema, K

    A lateral deviation of the walking trajectory is often observed in stroke patients with unilateral spatial neglect. However, existing research appears to be contradictory regarding the direction of this deviation. The aim of the present study was to gain more insight into the walking trajectory of

  15. Modulation and rehabilitation of spatial neglect by sensory stimulation.

    Science.gov (United States)

    Kerkhoff, Georg

    2003-01-01

    side effects. However, combined behavioural and drug treatments might yield better results. This has to be tested empirically in patient studies. In conclusion, the findings obtained in short-term sensory stimulation studies led to the development of effective techniques for the long-term rehabilitation of neglect. Future rehabilitation studies should evaluate effective treatment combinations considering all possible techniques and devices (behavioural, pharmacological, prosthetic or physiological).

  16. Performance of the Lester battery charger in electric vehicles

    Science.gov (United States)

    Vivian, H. C.; Bryant, J. A.

    1984-01-01

    Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.

  17. Batteries: Overview of Battery Cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Doeff, Marca M

    2010-07-12

    The very high theoretical capacity of lithium (3829 mAh/g) provided a compelling rationale from the 1970's onward for development of rechargeable batteries employing the elemental metal as an anode. The realization that some transition metal compounds undergo reductive lithium intercalation reactions reversibly allowed use of these materials as cathodes in these devices, most notably, TiS{sub 2}. Another intercalation compound, LiCoO{sub 2}, was described shortly thereafter but, because it was produced in the discharged state, was not considered to be of interest by battery companies at the time. Due to difficulties with the rechargeability of lithium and related safety concerns, however, alternative anodes were sought. The graphite intercalation compound (GIC) LiC{sub 6} was considered an attractive candidate but the high reactivity with commonly used electrolytic solutions containing organic solvents was recognized as a significant impediment to its use. The development of electrolytes that allowed the formation of a solid electrolyte interface (SEI) on surfaces of the carbon particles was a breakthrough that enabled commercialization of Li-ion batteries. In 1990, Sony announced the first commercial batteries based on a dual Li ion intercalation system. These devices are assembled in the discharged state, so that it is convenient to employ a prelithiated cathode such as LiCoO{sub 2} with the commonly used graphite anode. After charging, the batteries are ready to power devices. The practical realization of high energy density Li-ion batteries revolutionized the portable electronics industry, as evidenced by the widespread market penetration of mobile phones, laptop computers, digital music players, and other lightweight devices since the early 1990s. In 2009, worldwide sales of Li-ion batteries for these applications alone were US$ 7 billion. Furthermore, their performance characteristics (Figure 1) make them attractive for traction applications such as

  18. NEUROPSI ATTENTION AND MEMORY: a neuropsychological test battery in Spanish with norms by age and educational level.

    Science.gov (United States)

    Ostrosky-Solis, Feggy; Esther Gomez-Perez, Ma; Matute, Esmeralda; Rosselli, Monica; Ardila, Alfredo; Pineda, David

    2007-01-01

    Health care professionals are now faced with a growing number of patients from different ethnic groups, and from different socioeconomical backgrounds. In the field of neuropsychology there is an increasing need of reliable and culturally fair assessment measures. Spanish is the official language in more than 20 countries and the second most spoken language in the world. The purpose of this research was to develop and standardize the neuropsychological battery NEUROPSI ATTENTION AND MEMORY, designed to assess orientation, attention and concentration, executive functions, working memory and immediate and delayed verbal and visual memory. The developmental sequences of attention and memory as well as the educational effects were analyzed in a sample of 521 monolingual Spanish Speaking subjects, aged 6 to 85 years. Educational level ranged from 0 to 22 years of education. The consideration of the developmental sequence, and the effects of education, can improve the sensitivity and specificity of neuropsychological measures.

  19. The Judgment Test of the Neuropsychological Assessment Battery (NAB): psychometric considerations in an assisted-living sample.

    Science.gov (United States)

    MacDougall, Elizabeth E; Mansbach, William E

    2013-01-01

    A total of 82 older adults recruited from assisted-living facilities completed the Judgment subtest of the Neuropsychological Assessment Battery. The internal consistency reliability of Judgment scores in this sample, as estimated by Cronbach's α, was .83. Significant and strong Judgment score correlations with measures of general cognitive functioning and instrumental activities of daily living provided evidence of construct validity. Furthermore, participants who exhibited the capacity to consent to the evaluation performed significantly better on the Judgment subtest than did participants who did not exhibit consent capacity. Finally, Judgment scores predicted a significant proportion of variance in both instrumental and basic activities of daily living over and above the variance accounted for by scores on measures of general cognitive functioning and executive functioning. This study presents promising preliminary evidence of the incremental validity of Judgment subtest scores for predicting both basic and instrumental activities of daily living in an assisted-living sample.

  20. Aging investigations of a lithium-ion battery electrolyte from a field-tested hybrid electric vehicle

    Science.gov (United States)

    Grützke, Martin; Kraft, Vadim; Hoffmann, Björn; Klamor, Sebastian; Diekmann, Jan; Kwade, Arno; Winter, Martin; Nowak, Sascha

    2015-01-01

    The electrolyte of a used lithium-ion battery from a hybrid electric vehicle (HEV) was investigated. The liquid electrolyte was collected through the pressure valve of these 5 Ah cells. It consists of (29.8 ± 0.2) wt.% dimethyl carbonate (DMC), (21.7 ± 0.1) wt.% ethyl methyl carbonate (EMC), (30.3 ± 0.3) wt.% ethylene carbonate (EC) and (2.2 ± 0.1) wt.% cyclohexyl benzene (CHB) which were identified with GC-MS and quantified with GC-FID. Li+ (1.29 ± 0.04) mol L-1 and PF6- were determined with IC as the main ionic species in the solution. Furthermore, BF4- was clearly identified with IC-ESI-MS, IC-ICP-MS and 11B NMR and quantified to a concentration of (120.8 ± 8.3) mg L-1 with ICP-OES. The presence of POF3 (detected with GC-MS), F-, PO2F2-, HPO3F- and H2PO4- (determined with IC-ESI-MS) can be attributed to the reaction of the conducting salt LiPF6 via PF5 with traces of water. HPO3F- and H2PO4- could only be observed in cells which were opened in a laboratory hood under exposure of air humidity. This experiment was done to simulate escaping electrolyte from an HEV battery pack. Furthermore, several alkyl phosphates (identified with GC-MS and IC-ESI-MS) are present in the solution due to further reaction of the different fluorinated phosphates with organic carbonates.

  1. Primary battery design and safety guidelines handbook

    Science.gov (United States)

    Bragg, Bobby J.; Casey, John E.; Trout, J. Barry

    1994-12-01

    This handbook provides engineers and safety personnel with guidelines for the safe design or selection and use of primary batteries in spaceflight programs. Types of primary batteries described are silver oxide zinc alkaline, carbon-zinc, zinc-air alkaline, manganese dioxide-zionc alkaline, mercuric oxide-zinc alkaline, and lithium anode cells. Along with typical applications, the discussions of the individual battery types include electrochemistry, construction, capacities and configurations, and appropriate safety measures. A chapter on general battery safety covers hazard sources and controls applicable to all battery types. Guidelines are given for qualification and acceptance testing that should precede space applications. Permissible failure levels for NASA applications are discussed.

  2. Time course of visuospatial neglect early after stroke : A longitudinal cohort study

    NARCIS (Netherlands)

    Nijboer, Tanja C. W.; Kollen, Boudewijn J.; Kwakkel, Gert

    The aim of the current study was to investigate recovery of visuospatial neglect during the first year after stroke. Visuospatial neglect was measured using two frequently and widely used tests: the letter cancellation test (LCT) and the line bisection test (LBT). This was a prospective cohort study

  3. Dynamic assessment of visual neglect: The Mobility Assessment Course as a diagnostic tool.

    Science.gov (United States)

    Ten Brink, Antonia F; Visser-Meily, Johanna M A; Nijboer, Tanja C W

    2018-03-01

    Visual neglect is a frequent disorder following stroke and is often diagnosed by neuropsychological assessment. However, paper-and-pencil tasks have low predictive value as they lack sensitivity to capture neglect in complex, dynamic situations, such as activities of daily living. Aims of the current study were to assess the feasibility of the Mobility Assessment Course (MAC), a visual search multitask, to assess neglect, and its relation with existing neglect tasks. Stroke patients admitted for inpatient rehabilitation and healthy controls were tested with the MAC in different corridors. Participants had to move through a corridor, finding and reporting 24 targets attached to the walls. In addition, the shape cancellation, line bisection, and Catherine Bergego Scale (CBS) were used in order to compare the MAC with existing diagnostic tools for neglect. Administering the MAC was feasible, as 112 of 113 patients completed the MAC with a median duration of 4.09 min. Depending on the corridor where the assessment took place, in 88.5-93.3% of assessments all targets were visible. The number of omissions (total and contralesional) and the asymmetry score (contralesional-ipsilesional omissions) on the MAC as well as collisions and corrections, were higher for patients with neglect than for those without neglect. Depending on the neglect task used, 4.0-18.6% of patients without neglect on neuropsychological tasks or the CBS showed neglect on the MAC. Vice versa, 17.2-29.3% of patients who showed neglect at neuropsychological assessment or the CBS did not do so on the MAC. Finally, a moderate to strong positive relation was seen between neglect at neuropsychological assessment, the CBS, and the MAC. The MAC is an ecological task in which both quantitative and qualitative data on neglect can be collected. In order to assess the presence of neglect and neglect severity in a dynamic way, the MAC could be administered in conjunction with neuropsychological assessment.

  4. Polymorphisms of apolipoprotein E gene and cognitive functions of postmenopausal women, measured by battery of computer tests - Central Nervous System Vital Signs.

    Science.gov (United States)

    Bojar, Iwona; Wojcik-Fatla, Angelina; Owoc, Alfred; Lewinski, Andrzej

    2012-01-01

    Apolipoprotein E (APOE) gene belongs to the group of genes increasing the risk of the Alzheimer's disease (AD) development. The purpose of the study was the analysis of cognitive functions in postmenopausal women having different polymorphisms of APOE gene; battery of computer tests - Central Nervous System Vital Signs (CNS-VS) were employed. The women were qualified into the examined group on the grounds of clinical symptoms (minimum 2 years after the last menstruation), as well as on the basis of FSH concentration. At the qualification stage, a short test - Montreal Scale of Cognitive Function Assessment (MoCA) was conducted. The assessment of cognitive functions was made with the use of diagnostic CNS-Vital Signs equipment. Genomic DNA isolation was extracted from human whole blood. Multiplex PCR reactions have been performed in a single reaction tube with six (6) primers, consisting of 2 common primers and 4 specific primers [2 - for each of 2 single nucleotide polymorphism (SNP) sites]. About half of the examined postmenopausal women were placed below average in the majority of the examined cognitive functions. The biggest impairments occurred in the field of processing speed, and the smallest - in the field of verbal and visual memory. Polymorphisms of APOE gene were considerably linked with the level of results of the majority of cognitive functions among postmenopausal women, as measured by battery of computer tests - CNS-VS. The presence of ε2/ε3 polymorphism of APOE gene impacted positively the obtained results of cognitive functions, whereas the presence of ε3/ε4, or ε4/ε4 polymorphisms worsened the obtained results.

  5. Population normative data for the 10/66 Dementia Research Group cognitive test battery from Latin America, India and China: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    Yang Fang

    2009-08-01

    Full Text Available Abstract Background 1 To report site-specific normative values by age, sex and educational level for four components of the 10/66 Dementia Research Group cognitive test battery; 2 to estimate the main and interactive effects of age, sex, and educational level by site; and 3 to investigate the effect of site by region and by rural or urban location. Methods Population-based cross-sectional one phase catchment area surveys were conducted in Cuba, Dominican Republic, Venezuela, Peru, Mexico, China and India. The protocol included the administration of the Community Screening Instrument for Dementia (CSI 'D', generating the COGSCORE measure of global function, and the Consortium to Establish a Registry for Alzheimer's Disease (CERAD verbal fluency (VF, word list memory (WLM, immediate recall and recall (WLR, delayed recall tests. Only those free of dementia were included in the analysis. Results Older people, and those with less education performed worse on all four tests. The effect of sex was much smaller and less consistent. There was a considerable effect of site after accounting for compositional differences in age, education and sex. Much of this was accounted for by the effect of region with Chinese participants performing better, and Indian participants worse, than those from Latin America. The effect of region was more prominent for VF and WLM than for COGSCORE and WLR. Conclusion Cognitive assessment is a basic element for dementia diagnosis. Age- and education-specific norms are required for this purpose, while the effect of gender can probably be ignored. The basis of cultural effects is poorly understood, but our findings serve to emphasise that normative data may not be safely generalised from one population to another with quite different characteristics. The minimal effects of region on COGSCORE and WLR are reassuring with respect to the cross-cultural validity of the 10/66 dementia diagnosis, which uses only these elements of the 10

  6. Pharmacological evaluation of novel 5-HT 3 receptor antagonist, QCM-13 (N-cyclohexyl-3-methoxyquinoxalin-2-carboxamide as anti-anxiety agent in behavioral test battery

    Directory of Open Access Journals (Sweden)

    Deepali Gupta

    2015-01-01

    Full Text Available Objective: In the last few decades, serotonin type-3 (5-HT 3 receptor antagonists have been identified as potential targets for anxiety disorders. In preclinical studies, 5-HT 3 antagonists have shown promising antianxiety effects. In this study, a novel 5-HT 3 receptor antagonist, QCM-13(N-cyclohexyl-3-methoxyquinoxalin-2-carboxamide was evaluated for anxiolytic-like activity in rodent behavioral test battery. Materials and Methods: Mice were given QCM-13 (2 and 4 mg/kg, intraperitoneally [i.p.] or diazepam (2 mg/kg, i.p. or vehicle and after 30 min, mice were subjected to four validated behavioral test batteries viz. elevated plus maze, hole board, light-dark and open field tests. Interaction study of QCM-13 with m-chlorophenyl piperazine (mCPP (mCPP, a 5-HT 2A/2C receptor agonist, 1 mg/kg, i.p. and buspirone (BUS, a partial 5-HT 1A agonist, 10 mg/kg, i.p. were performed to assess the pharmacological mechanism of the drug. Results: QCM-13 expressed potential anxiolytic effect with significant (P < 0.05 increase in behavioral parameters measured in aforementioned preliminary models. Besides, QCM-13 was unable to reverse the anxiogenic effect of mCPP, but potentiated anxiolytic affect of BUS. Conclusion: The results suggest that QCM-13 can be a potential therapeutic candidate for the management of anxiety-like disorders and combination doses of novel 5-HT 3 receptor antagonist with standard anxiolytics may improve therapeutic efficacy.

  7. Validação da bateria "Beck" de testes de habilidades para atletas brasileiros de "rugby" em cadeira de rodas Validation of beck battery of skills tests to Brazilian players of wheelchair rugby

    Directory of Open Access Journals (Sweden)

    José Irineu Gorla

    2011-09-01

    Full Text Available O "Rugby" em Cadeira de Rodas é uma modalidade praticada por sujeitos com tetraplegia ou tetra-equivalência, desde 2005 no Brasil, onde existem aproximadamente 10 equipes em atividade. A avaliação motora é um dos meios de controle do treinamento que possibilita conquistar avanços no planejamento. A bateria "Beck" de testes de habilidades (manejo de bola, precisão de passes, bloqueio, velocidade e passes de longa distância para atletas da modalidade foi desenvolvida nos EUA por Yilla e Sherrill (1998. O objetivo deste estudo foi analisar os critérios de autenticidade científica da bateria para a população de atletas brasileiros. Os resultados de duas avaliações com a bateria (teste e re-teste realizadas com 11 atletas (média de idade 27,59 ± 5,37 anos, tempo de lesão 8,19 ± 3,83 anos, foram registrados por três avaliadores, o que possibilitou a análise de objetividade, fidedignidade e consistência interna. Foram utilizadas as ferramentas ANOVA para análise de objetividade e, coeficiente de correlação intraclasse e teste t para análise de fidedignidade e consistência. Não foram encontradas diferenças entre os resultados dos diferentes avaliadores (valores de p variando de 0,45 a 1,00 e os valores de correlação intraclasse encontrados (variação de r de 0,78 a 0,99 permitem concluir que a bateria é consistente e fidedigna. Os resultados encontrados neste estudo são evidências de que os critérios de autenticidade científica para a bateria são satisfeitos e a bateria pode ser considerada um instrumento válido para avaliação motora de atletas brasileiros de "rugby" em cadeira de rodas.The Wheelchair Rugby is a sport practiced by subjects with tetraplegia or tetra-equivalence, since 2005 in Brazil, where there are approximately 10 teams in business. The motricity evaluation is a means of training control that allows achieve real progress in planning. The BECK battery of skills tests (ball handling, precision

  8. International Space Station Lithium-Ion Battery

    Science.gov (United States)

    Dalton, Penni J.; Schwanbeck, Eugene; North, Tim; Balcer, Sonia

    2016-01-01

    The International Space Station (ISS) primary Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. When deployed, they will be the largest Li-Ion batteries ever utilized for a human-rated spacecraft. This paper will include an overview of the ISS Li-Ion battery system architecture, the Li-Ion battery design and development, controls to limit potential hazards from the batteries, and the status of the Li-Ion cell and ORU life cycle testing.

  9. The attenuation of auditory neglect by implicit cues.

    Science.gov (United States)

    Coleman, A Rand; Williams, J Michael

    2006-09-01

    This study examined implicit semantic and rhyming cues on perception of auditory stimuli among nonaphasic participants who suffered a lesion of the right cerebral hemisphere and auditory neglect of sound perceived by the left ear. Because language represents an elaborate processing of auditory stimuli and the language centers were intact among these patients, it was hypothesized that interactive verbal stimuli presented in a dichotic manner would attenuate neglect. The selected participants were administered an experimental dichotic listening test composed of six types of word pairs: unrelated words, synonyms, antonyms, categorically related words, compound words, and rhyming words. Presentation of word pairs that were semantically related resulted in a dramatic reduction of auditory neglect. Dichotic presentations of rhyming words exacerbated auditory neglect. These findings suggest that the perception of auditory information is strongly affected by the specific content conveyed by the auditory system. Language centers will process a degraded stimulus that contains salient language content. A degraded auditory stimulus is neglected if it is devoid of content that activates the language centers or other cognitive systems. In general, these findings suggest that auditory neglect involves a complex interaction of intact and impaired cerebral processing centers with content that is selectively processed by these centers.

  10. Other Safety Concerns and Self-Neglect

    Science.gov (United States)

    ... Asked Questions DONATE Other Safety Concerns and Self-Neglect Other safety concerns focus on instances of seniors ... When To Report Other Safety Concerns and Self-Neglect? If you witness a life-threatening situation involving ...

  11. Lithium-thionyl chloride batteries - past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    McCartney, J.F.; Lund, T.J.; Sturgeon, W.J.

    1980-02-01

    Lithium based batteries have the highest theoretical energy density of known battery types. Of the lithium batteries, the lithium-thionyl chloride electrochemistry has the highest energy density of those which have been reduced to practice. The characteristics, development status, and performance of lithium-thionyl chloride batteries are treated in this paper. Safety aspects of lithium-thionyl chloride batteries are discussed along with impressive results of hazard/safety tests of these batteries. An orderly development plan of a minimum family of standard cells to avoid a proliferation of battery sizes and discharge rates is presented.

  12. Battery Safety Basics

    Science.gov (United States)

    Roy, Ken

    2010-01-01

    Batteries commonly used in flashlights and other household devices produce hydrogen gas as a product of zinc electrode corrosion. The amount of gas produced is affected by the batteries' design and charge rate. Dangerous levels of hydrogen gas can be released if battery types are mixed, batteries are damaged, batteries are of different ages, or…

  13. Polypropylene/hydrophobic-silica-aerogel-composite separator induced enhanced safety and low polarization for lithium-ion batteries

    Science.gov (United States)

    Feng, Guanhua; Li, Zihe; Mi, Liwei; Zheng, Jinyun; Feng, Xiangming; Chen, Weihua

    2018-02-01

    Separator as an important part of lithium-ion batteries, allowing the ion to transfer and preventing the direct contact of anode with cathode, determines the safety of the batteries. In this work, a kind of polypropylene/hydrophobic silica-aerogel-composite (SAC) separator is fabricated through combining hydrophobic silica aerogel and polypropylene (PP) separator. The rationally designed SAC effectively increases the thermal stability of the separator with slightly growing weight (the area retention rate is 30% higher than that of the PP separator after being heated for 30 min at 160 °C). In addition, the hydrophobic silica aerogel layer in SAC significantly improves the wettability of PP separator to electrolyte owning to the introduced hydrophobic functional groups of -Si(CH3)3 and porous structure, and the contact angles of SAC separator to several common organic electrolytes (EC/DMC, DMC/DOL, Diglyme) are close to 0°. Electrochemical tests show that the prepared SAC separator can decrease the polarization of Li-ion batteries and leads to improved power performance and cycle stability. And the SAC separator is firm with neglectable abscission after folding 200 times. This work provides a new way to improve the safety and simultaneously reduce the polarization of the batteries, implying promising application potential in power batteries.

  14. Neglect and Motion Stimuli – Insights from a Touchscreen-Based Cancellation Task

    Science.gov (United States)

    Cazzoli, Dario; Gutbrod, Klemens; Laube-Rosenpflanzer, Annett; Chechlacz, Magdalena; Nef, Tobias; Mosimann, Urs; Bohlhalter, Stephan; Müri, René M.; Nyffeler, Thomas

    2015-01-01

    Background and Purpose In stroke patients, neglect diagnostic is often performed by means of paper-pencil cancellation tasks. These tasks entail static stimuli, and provide no information concerning possible changes in the severity of neglect symptoms when patients are confronted with motion. We therefore aimed to directly contrast the cancellation behaviour of neglect patients under static and dynamic conditions. Since visual field deficits often occur in neglect patients, we analysed whether the integrity of the optic radiation would influence cancellation behaviour. Methods Twenty-five patients with left spatial neglect after right-hemispheric stroke were tested with a touchscreen cancellation task, once when the evenly distributed targets were stationary, and once when the identic targets moved with constant speed on a random path. The integrity of the right optic radiation was analysed by means of a hodologic probabilistic approach. Results Motion influenced the cancellation behaviour of neglect patients, and the direction of this influence (i.e., an increase or decrease of neglect severity) was modulated by the integrity of the right optic radiation. In patients with an intact optic radiation, the severity of neglect significantly decreased in the dynamic condition. Conversely, in patients with damage to the optic radiation, the severity of neglect significantly increased in the dynamic condition. Conclusion Motion may influence neglect in stroke patients. The integrity of the optic radiation may be a predictor of whether motion increases or decreases the severity of neglect symptoms. PMID:26158619

  15. Effect of methylphenidate on neurocognitive test battery: an evaluation according to the diagnostic and statistical manual of mental disorders, fourth edition, subtypes.

    Science.gov (United States)

    Durak, Sibel; Ercan, Eyup Sabri; Ardic, Ulku Akyol; Yuce, Deniz; Ercan, Elif; Ipci, Melis

    2014-08-01

    The aims of this study were to evaluate the neuropsychological characteristics of the restrictive (R) subtype according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition and the attention-deficit/hyperactivity disorder (ADHD) combined (CB) type and predominantly inattentive (PI) type subtypes and to evaluate whether methylphenidate (MPH) affects neurocognitive test battery scores according to these subtypes. This study included 360 children and adolescents (277 boys, 83 girls) between 7 and 15 years of age who had been diagnosed with ADHD and compared the neuropsychological characteristics and MPH treatment responses of patients with the R subtype-which has been suggested for inclusion among the ADHD subtypes in the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition-with those of patients with the PI and CB subtypes. They did not differ from the control subjects in the complex attention domain, which includes Continuous Performance Test, Stroop test, and Shifting Attention Test, which suggests that the R subtype displayed a lower level of deterioration in these domains compared with the PI and CB subtypes. The patients with the CB and PI subtypes did not differ from the control subjects in the Continuous Performance Test correct response domain, whereas those with the R subtype presented a poorer performance than the control subjects. The R subtype requires a more detailed evaluation because it presented similar results in the remaining neuropsychological evaluations and MPH responses.

  16. What Is Child Abuse and Neglect?

    Science.gov (United States)

    US Department of Health and Human Services, 2006

    2006-01-01

    Each State provides its own definitions of child abuse and neglect based on minimum standards set by Federal law. This fact sheet provides the answers to the following questions: (1) How is child abuse and neglect defined in Federal law?; and (2) What are the major types of child abuse and neglect? Additional resources are listed. (Contains 2…

  17. FY2016 Advanced Batteries R&D Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-08-31

    The Advanced Batteries research and development (R&D) subprogram within the DOE Vehicle Technologies Office (VTO) provides support and guidance for projects focusing on batteries for plug-in electric vehicles. Program targets focus on overcoming technical barriers to enable market success including: (1) significantly reducing battery cost, (2) increasing battery performance (power, energy, durability), (3) reducing battery weight & volume, and (4) increasing battery tolerance to abusive conditions such as short circuit, overcharge, and crush. This report describes the progress made on the research and development projects funded by the Battery subprogram in 2016. This section covers the Vehicle Technologies Office overview; the Battery subprogram R&D overview; Advanced Battery Development project summaries; and Battery Testing, Analysis, and Design project summaries. It also includes the cover and table of contents.

  18. Severe Neglect and Computer-based Home Training

    DEFF Research Database (Denmark)

    Wilms, Inge Linda

    2014-01-01

    Abstract. Cognitive rehabilitation from a functional perspective often requires intensive training over a longer period of time. In the case of rehabilitation of unilateral neglect, the frequency and intensity needed is expensive and difficult to implement both for the therapists and the patients....... For this reason, this case study tests the possibility of using computer-based training in the rehabilitation efforts for a patient with severe neglect who had no previous skills in computer usage. The article describes the results of the training both in terms of neuro-psychological tests and the reading ability...

  19. Homocysteine and Cognitive Performance in Elders with Self-Neglect

    Science.gov (United States)

    Burnett, J.; Smith, S.M.; Aung, K.; Dyer, C.

    2009-01-01

    Elevated plasma homocysteine has been associated with altered cognitive performance in older adults. Elders referred to Adult Protective Services (APS) for self-neglect have been reported to have elevated plasma homocysteine levels and to suffer from cognitive impairment. This study assesses the association, if any, between plasma homocysteine and cognitive performance among elders with self-neglect. Methods: Sixty-five community-living adults, 65 years of age and older, reported to Adult Protective Services for self-neglect and 55 matched controls (matched for age, ethnicity, gender and socio-economic status) consented and participated in this study. The research team conducted in-home comprehensive geriatric assessments which included the mini-mental state exam (MMSE), the 15-item geriatric depression scale (GDS), the Wolf-Klein Clock Drawing Tests (CDT) and a comprehensive nutritional biochemistry panel, which included plasma homocysteine. Student s t tests and Pearson correlations were conducted to assess for bivariate associations. Results: Elders with self-neglect had significantly higher plasma homocysteine levels (M=12.68umol/L, sd=4.4) compared to the controls (M=10.40umol/L, sd=3.61;t=3.21, df=127, p=.002). There were no statistically significant associations between cognitive performance and plasma homocysteine in the self-neglect group, however there was a significant correlation between plasma homocysteine and the CDT among the controls (r=-.296, p=.022). Conclusion: Mean plasma homocysteine levels were significantly higher in elders with self-neglect, however, they do not appear to be related to cognitive performance, indicating that cognitive impairment in elder self-neglect involve mechanisms other than hyperhomocysteinemia. These findings warrant further investigation

  20. Two-dimensional cancellation neglect a review and suggested method of analysis.

    Science.gov (United States)

    Mark, V W; Monson, N

    1997-09-01

    Directional bias on cancellation has thus far not been standardized. While cancellation tasks are primarily used to assess lateral performance asymmetries, they may also reveal two-dimensional (i.e., combined lateral and radial) neglect patterns. We propose a method to evaluate and report cancellation neglect regardless of whether the neglect pattern is strictly unilateral or two-dimensional. Our method establishes the location of the geographic center of all neglected stimuli relative to the page center by averaging their Cartesian coordinates. This "neglect center" is reported in polar coordinates to indicate its distance and direction from the page center. We apply our method to published examples of two-dimensional neglect. We find that neglect centers from different cancellation performances may not be statistically distinct even though they may occupy different quadrants. In addition, the net direction of neglect found by the coordinate method may differ from that inferred from measuring differences in quadrant omission totals. The suitability of the coordinate vs. the quadrant method will depend on the mechanism hypothesized for visuospatial exploration under particular test conditions. Using both approaches may detect different attentional biases operating during the same task. The coordinate method is appropriate for conventional cancellation testing. By incorporating the precise locations of all neglected stimuli and determining the net neglect direction in two dimensions, the technique may stimulate more comprehensive explanations for directional bias.

  1. Effect of subtypes of neglect on functional outcome in stroke patients.

    Science.gov (United States)

    Spaccavento, Simona; Cellamare, Fara; Falcone, Rosanna; Loverre, Anna; Nardulli, Roberto

    2017-11-01

    Because of the loss of autonomy in daily-life activities, spatial neglect after stroke is one of the main causes of disability. According to the spatial domains, neglect can be divided into personal (body), peripersonal (reaching) and extrapersonal (far) space. We evaluated the effect of these subtypes of neglect on functional outcome of rehabilitation in stroke patients. A total of 1350 stroke patients were consecutively admitted into our neurorehabilitation unit from 2002 to 2016. We analyzed data for patients with a first ischemic or hemorrhagic right-hemispheric stroke in this observational retrospective study. The presence of neglect was evaluated by using structured tests for specific spatial domains. Patients underwent individual physical and occupational therapy, and those with neglect received specific therapy for 8 consecutive weeks consisting of visual scanning, reading and copying, copying line drawings on a dot matrix and describing scenes. The Functional Independence Measure (FIM) instrument was administered at both admission and discharge to assess functional autonomy. Rehabilitation effectiveness for FIM (percentage of potential improvement achieved) was calculated. Multiple regression analyses were performed. Among 359 patients with right-brain damage, 130 showed left neglect, or unilateral spatial neglect (USN), and 229 only left hemiparesis, without neglect. Overall, 90 patients (69%) with USN showed peripersonal neglect, 89 (68%) extrapersonal neglect and 60 (46%) personal neglect. Functional motor and cognitive impairment was greater with than without USN as measured by FIM at admission and discharge and the rehabilitation hospital stay was longer. USN affected functional status at admission and rehabilitation effectiveness for FIM. Extrapersonal and peripersonal neglect significantly affected both function at admission and effectiveness. Our data confirm the negative prognostic effect of neglect on functional outcome in a large sample. We also

  2. Clinical relevance of the modified physical performance test versus the short physical performance battery for detecting mobility impairments in older men with peripheral arterial disease.

    Science.gov (United States)

    Addison, Odessa; Kundi, Rishi; Ryan, Alice S; Goldberg, Andrew P; Patel, Richa; Lal, Brajesh K; Prior, Steven J

    2017-08-23

    The study is to compare the Modified Physical Performance Test (MPPT) and Short Physical Performance Battery (SPPB) as metrics of mobility and function in older men with peripheral arterial disease (PAD). A total of 51 men (55-87 years) with PAD underwent functional testing including the SPPB, MPPT, Walking Impairment Questionnaire (WIQ), stair ascent, and 6-min walk distance. Individuals were grouped according to SPPB and MPPT scores as not limited on either, limited only on the MPPT, or limited on both. The MPPT identified a higher proportion of patients as being functionally limited than the SPPB (p MPPT, and not the SPPB, were subsequently confirmed to have lower function on all measures compared to those not identified as limited by either the SPPB or the MPPT (p MPPT is an appropriate measure to identify early declines in men with PAD and may identify global disability better than SPPB. Implications for rehabilitation Individuals with peripheral arterial disease have low activity levels and are at risk for a loss of independence and global disability. Early detection of decline in mobility and global function would allow for interventions before large changes in ambulatory ability or a loss of functional independence occur. This study shows the Modified Physical Performance Test may be an appropriate test to identify early decline in function in men with peripheral arterial disease.

  3. The Philadelphia Face Perception Battery

    Science.gov (United States)

    Thomas, Amy; Lawler, Kathy; Olson, Ingrid R; Aguirre, Geoffrey K

    2008-01-01

    The Philadelphia Face Perception Battery (PFPB) tests four aspects of face perception: discrimination of facial similarity, attractiveness, gender, and age. Calibration with 116 neurologically intact subjects yielded average performance of ~90%. Across subjects, there was a low correlation (perception. There were modest effects of subject demographic factors upon performance, and test-retest reliability scores (between 0.37 and 0.75) were comparable to other neuropsychological batteries. Modification of the stimuli to obscure internal facial features lowered performance on the age, gender, and attractiveness discrimination tests between 2 and 4 standard deviations. The clinical sensitivity of the battery was demonstrated by testing a patient with acquired prosopagnosia. She showed performance impairments of between 2 and 4 standard deviations on all sub-tests. The PFPB is freely available for non-commercial use. PMID:18082362

  4. Radioactive battery

    International Nuclear Information System (INIS)

    Deaton, R.L.; Silver, G.L.

    1975-01-01

    A radioactive battery is described that is comprised of a container housing an electrolyte, two electrodes immersed in the electrolyte and insoluble radioactive material disposed adjacent one electrode. Insoluble radioactive material of different intensity of radioactivity may be disposed adjacent the second electrode. If hydrobromic acid is used as the electrolyte, Br 2 will be generated by the radioactivity and is reduced at the cathode: Br 2 + 2e = 2 Br - . At the anode Br - is oxidized: 2Br - = Br 2 + 2e. (U.S.)

  5. Development of a Physical Employment Testing Battery for Infantry Soldiers: 11B Infantryman and 11C Infantryman-Indirect Fire

    Science.gov (United States)

    2015-12-01

    the Army Physical Fitness Test (APFT). This test creates a score based on the number of push-ups performed in two minutes, the number of sit-ups...signed a consent form, and completed questionnaires about their demographics and most recent Army Physical Fitness Test (APFT). Height and weight in...studies will be conducted at Ft Stewart, GA to identify simple physical fitness tests that can be used to predict performance on the task simulations

  6. Children neglected: Where cumulative risk theory fails.

    Science.gov (United States)

    O'Hara, Mandy; Legano, Lori; Homel, Peter; Walker-Descartes, Ingrid; Rojas, Mary; Laraque, Danielle

    2015-07-01

    Neglected children, by far the majority of children maltreated, experience an environment most deficient in cognitive stimulation and language exchange. When physical abuse co-occurs with neglect, there is more stimulation through negative parent-child interaction, which may lead to better cognitive outcomes, contrary to Cumulative Risk Theory. The purpose of the current study was to assess whether children only neglected perform worse on cognitive tasks than children neglected and physically abused. Utilizing LONGSCAN archived data, 271 children only neglected and 101 children neglected and physically abused in the first four years of life were compared. The two groups were assessed at age 6 on the WPPSI-R vocabulary and block design subtests, correlates of cognitive intelligence. Regression analyses were performed, controlling for additional predictors of poor cognitive outcome, including socioeconomic variables and caregiver depression. Children only neglected scored significantly worse than children neglected and abused on the WPPSI-R vocabulary subtest (p=0.03). The groups did not differ on the block design subtest (p=0.4). This study shows that for neglected children, additional abuse may not additively accumulate risk when considering intelligence outcomes. Children experiencing only neglect may need to be referred for services that address cognitive development, with emphasis on the linguistic environment, in order to best support the developmental challenges of neglected children. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. White matter lesional predictors of chronic visual neglect: a longitudinal study

    Science.gov (United States)

    Lunven, Marine; Thiebaut De Schotten, Michel; Bourlon, Clémence; Duret, Christophe; Migliaccio, Raffaella; Rode, Gilles

    2015-01-01

    Chronic visual neglect prevents brain-damaged patients from returning to an independent and active life. Detecting predictors of persistent neglect as early as possible after the stroke is therefore crucial to plan the relevant interventions. Neglect signs do not only depend on focal brain lesions, but also on dysfunction of large-scale brain networks connected by white matter bundles. We explored the relationship between markers of axonal degeneration occurring after the stroke and visual neglect chronicity. A group of 45 patients with unilateral strokes in the right hemisphere underwent cognitive testing for neglect twice, first at the subacute phase (1 year). For each patient, magnetic resonance imaging including diffusion sequences was performed at least 4 months after the stroke. After masking each patient’s lesion, we used tract-based spatial statistics to obtain a voxel-wise statistical analysis of the fractional anisotropy data. Twenty-seven patients had signs of visual neglect at initial testing. Only 10 of these patients had recovered from neglect at follow-up. When compared with patients without neglect, the group including all subacute neglect patients had decreased fractional anisotropy in the second (II) and third (III) branches of the right superior longitudinal fasciculus, as well as in the splenium of the corpus callosum. The subgroup of chronic patients showed reduced fractional anisotropy in a portion the splenium, the forceps major, which provides interhemispheric communication between regions of the occipital lobe and of the superior parietal lobules. The severity of neglect correlated with fractional anisotropy values in superior longitudinal fasciculus II/III for subacute patients and in its caudal portion for chronic patients. Our results confirm a key role of fronto-parietal disconnection in the emergence and chronic persistence of neglect, and demonstrate an implication of caudal interhemispheric disconnection in chronic neglect

  8. Household batteries: Evaluation of collection methods

    Energy Technology Data Exchange (ETDEWEB)

    Seeberger, D.A.

    1992-12-31

    While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are discussed.

  9. Household batteries: Evaluation of collection methods

    Energy Technology Data Exchange (ETDEWEB)

    Seeberger, D.A.

    1992-01-01

    While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are discussed.

  10. Optimization of station battery replacement

    International Nuclear Information System (INIS)

    Jancauskas, J.R.; Shook, D.A.

    1994-01-01

    During a loss of ac power at a nuclear generating station (including diesel generators), batteries provide the source of power which is required to operate safety-related components. Because traditional lead-acid batteries have a qualified life of 20 years, the batteries must be replaced a minimum of once during a station's lifetime, twice if license extension is pursued, and more often depending on actual in-service dates and the results of surveillance tests. Replacement of batteries often occurs prior to 20 years as a result of systems changes caused by factors such as Station Blackout Regulations, control system upgrades, incremental load growth, and changes in the operating times of existing equipment. Many of these replacement decisions are based on the predictive capabilities of manual design basis calculations. The inherent conservatism of manual calculations may result in battery replacements occurring before actually required. Computerized analysis of batteries can aid in optimizing the timing of replacements as well as in interpreting service test data. Computerized analysis also provides large benefits in maintaining the as-configured load profile and corresponding design margins, while also providing the capability of quickly analyze proposed modifications and response to internal and external audits

  11. Optimization of station battery replacement

    Science.gov (United States)

    Jancauskas, J. R.; Shook, D. A.

    1994-08-01

    During a loss of ac power at a nuclear generating station (including diesel generators), batteries provide the source of power which is required to operate safety-related components. Because traditional lead-acid batteries have a qualified life of 20 years, the batteries must be replaced a minimum of once during a station's lifetime, twice if license extension is pursued, and more often depending on actual in-service dates and the results of surveillance tests. Replacement of batteries often occurs prior to 20 years as a result of systems changes caused by factors such as Station Blackout Regulations, control system upgrades, incremental load growth, and changes in the operating times of existing equipment. Many of these replacement decisions are based on the predictive capabilities of manual design basis calculations. The inherent conservatism of manual calculations may result in battery replacements occurring before actually required. Computerized analysis of batteries can aid in optimizing the timing of replacements as well as in interpreting service test data. Computerized analysis also provides large benefits in maintaining the as-configured load profile and corresponding design margins, while also providing the capability to quickly analyze proposed modifications and respond to internal and external audits.

  12. Lesion Sites Associated with Allocentric and Egocentric Visuospatial Neglect in Acute Stroke.

    Science.gov (United States)

    Kenzie, Jeffrey M; Girgulis, Katie A; Semrau, Jennifer A; Findlater, Sonja E; Desai, Jamsheed A; Dukelow, Sean P

    2015-09-01

    Visuospatial neglect is a disorder that can often result from stroke and is characterized by an inability to attend to contralesional stimuli. Two common subtypes include allocentric (object-centered) neglect and egocentric (viewer-centered) neglect. In allocentric neglect, spatial inattention is localized to the contralesional side of an object regardless of its relative position to the observer. In egocentric neglect, spatial inattention is localized to the contralesional side of the individual's midline. The neuroanatomical correlates of each subtype are unknown. However, recent work has suggested that damage to temporal, inferior parietal, and occipital areas may result in allocentric neglect and that damage to frontoparietal areas may result in egocentric neglect. We used voxel-based lesion-symptom mapping (VLSM) to compare lesion location to behavioral performance on the conventional six subtests of the Behavioral Inattention Test (BIT) in 62 subjects with acute right hemisphere ischemic stroke. Results identified an anatomical dissociation in lesion location between subjects with neglect based on poor performance on allocentric tests (line bisection, copying, and drawing tasks) and on egocentric tests (star, letter, and line cancellation). VLSM analyses revealed that poor performance on the allocentric tests was associated with lesions to the superior and inferior parietal cortices, and the superior and middle temporal gyri. In contrast, poor performance on the egocentric tests was associated with lesions in the precentral gyrus, middle frontal gyrus, insula, and putamen. Interestingly, the letter cancellation test and average performance on egocentric tests were associated with frontal and parietal lesions. Some of these parietal lesion locations overlapped with lesion locations associated with allocentric neglect. These findings are consistent with suggestions that damage to temporal and parietal areas is more associated with allocentric neglect and damage

  13. An averaging battery model for a lead-acid battery operating in an electric car

    Science.gov (United States)

    Bozek, J. M.

    1979-01-01

    A battery model is developed based on time averaging the current or power, and is shown to be an effective means of predicting the performance of a lead acid battery. The effectiveness of this battery model was tested on battery discharge profiles expected during the operation of an electric vehicle following the various SAE J227a driving schedules. The averaging model predicts the performance of a battery that is periodically charged (regenerated) if the regeneration energy is assumed to be converted to retrievable electrochemical energy on a one-to-one basis.

  14. Relations Between the Intelligibility of Speech in Noise and Psychophysical Measures of Hearing Measured in Four Languages Using the Auditory Profile Test Battery

    Directory of Open Access Journals (Sweden)

    T. E. M. Van Esch

    2015-12-01

    Full Text Available The aim of the present study was to determine the relations between the intelligibility of speech in noise and measures of auditory resolution, loudness recruitment, and cognitive function. The analyses were based on data published earlier as part of the presentation of the Auditory Profile, a test battery implemented in four languages. Tests of the intelligibility of speech, resolution, loudness recruitment, and lexical decision making were measured using headphones in five centers: in Germany, the Netherlands, Sweden, and the United Kingdom. Correlations and stepwise linear regression models were calculated. In sum, 72 hearing-impaired listeners aged 22 to 91 years with a broad range of hearing losses were included in the study. Several significant correlations were found with the intelligibility of speech in noise. Stepwise linear regression analyses showed that pure-tone average, age, spectral and temporal resolution, and loudness recruitment were significant predictors of the intelligibility of speech in fluctuating noise. Complex interrelationships between auditory factors and the intelligibility of speech in noise were revealed using the Auditory Profile data set in four languages. After taking into account the effects of pure-tone average and age, spectral and temporal resolution and loudness recruitment had an added value in the prediction of variation among listeners with respect to the intelligibility of speech in noise. The results of the lexical decision making test were not related to the intelligibility of speech in noise, in the population studied.

  15. Relations Between the Intelligibility of Speech in Noise and Psychophysical Measures of Hearing Measured in Four Languages Using the Auditory Profile Test Battery.

    Science.gov (United States)

    Van Esch, T E M; Dreschler, W A

    2015-12-08

    The aim of the present study was to determine the relations between the intelligibility of speech in noise and measures of auditory resolution, loudness recruitment, and cognitive function. The analyses were based on data published earlier as part of the presentation of the Auditory Profile, a test battery implemented in four languages. Tests of the intelligibility of speech, resolution, loudness recruitment, and lexical decision making were measured using headphones in five centers: in Germany, the Netherlands, Sweden, and the United Kingdom. Correlations and stepwise linear regression models were calculated. In sum, 72 hearing-impaired listeners aged 22 to 91 years with a broad range of hearing losses were included in the study. Several significant correlations were found with the intelligibility of speech in noise. Stepwise linear regression analyses showed that pure-tone average, age, spectral and temporal resolution, and loudness recruitment were significant predictors of the intelligibility of speech in fluctuating noise. Complex interrelationships between auditory factors and the intelligibility of speech in noise were revealed using the Auditory Profile data set in four languages. After taking into account the effects of pure-tone average and age, spectral and temporal resolution and loudness recruitment had an added value in the prediction of variation among listeners with respect to the intelligibility of speech in noise. The results of the lexical decision making test were not related to the intelligibility of speech in noise, in the population studied. © The Author(s) 2015.

  16. Online and offline awareness deficits: Anosognosia for spatial neglect.

    Science.gov (United States)

    Chen, Peii; Toglia, Joan

    2018-04-12

    Anosognosia for spatial neglect (ASN) can be offline or online. Offline ASN is general unawareness of having experienced spatial deficits. Online ASN is an awareness deficit of underestimating spatial difficulties that likely to occur in an upcoming task (anticipatory ASN) or have just occurred during the task (emergent ASN). We explored the relationships among spatial neglect, offline ASN, anticipatory ASN, and emergent ASN. Research Method/Design: Forty-four survivors of stroke answered questionnaires assessing offline and online self-awareness of spatial problems. The online questionnaire was asked immediately before and after each of 4 tests for spatial neglect, including shape cancellation, address and sentence copying, telephone dialing, and indented paragraph reading. Participants were certain they had difficulties in daily spatial tasks (offline awareness), in the task they were about to perform (anticipatory awareness) and had just performed (emergent awareness). Nonetheless, they consistently overestimated their spatial abilities, indicating ASN. Offline and online ASN appeared independent. Online ASN improved after task execution. Neglect severity was not positively correlated with offline ASN. Greater neglect severity correlated with both greater anticipatory and emergent ASN. Regardless of neglect severity, we found task-specific differences in emergent ASN but not in anticipatory ASN. Individuals with spatial neglect acknowledge their spatial difficulty (certainty of error occurrence) but may not necessarily recognize the extent of their difficulty (accuracy of error estimation). Our findings suggest that offline and online ASN are independent. A potential implication from the study is that familiar and challenging tasks may facilitate emergence of self-awareness. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  17. Identifying risk factors for child neglect in rural areas of western China.

    Science.gov (United States)

    Li, Q; Zhong, Y; Chen, K; Zhong, Z; Pan, J

    2015-11-01

    Children who are neglected can experience serious and lifelong consequences. Earlier identification of children at risk for child neglect might reduce the individual, medical and societal costs. A cross-sectional survey using multi-stage stratified cluster random sampling was conducted in Shaanxi and Chongqing from September 2012 to April 2013. The child neglect was measured by scale on child neglect in Rural China. The neglect rates between groups were compared with a chi-squared test. Factors possibly associated with neglect were analysed with binary logistic regression. All analyses were conducted in 2014. A total of 4131 eligible participants (2094 boys and 2037 girls) from 21 schools were recruited. The overall prevalence of child neglect was 55.50%. Significant differences were found between children of Han nationality (53.07%) and children of minorities (68.76%) (P neglect. The neglect rate of school-aged children in rural areas of western China is much higher than that in urban areas and eastern China. Children belonging to minorities, step families and multi-child families, whose mother seldom goes home, are at a higher risk of being neglected. The left-behind children deserve more attention from government and researchers. © 2015 John Wiley & Sons Ltd.

  18. Lithium-Thionyl Chloride Batteries for the Mars Pathfinder Microrover

    Energy Technology Data Exchange (ETDEWEB)

    Deligiannis, F.; Frank, H.; Staniewicz, R.J.; Willson, J. [SAFT America, Inc., Cockeysville, MD (United States)

    1996-02-01

    A discussion of the power requirements for the Mars Pathfinder Mission is given. Topics include: battery requirements; cell design; battery design; test descriptions and results. A summary of the results is also included.

  19. Lithium-Thionyl Chloride Batteries for the Mars Pathfinder Microrover

    Science.gov (United States)

    Deligiannis, Frank; Frank, Harvey; Staniewicz, R. J.; Willson, John

    1996-01-01

    A discussion of the power requirements for the Mars Pathfinder Mission is given. Topics include: battery requirements; cell design; battery design; test descriptions and results. A summary of the results is also included.

  20. Stand Alone Battery Thermal Management System

    Energy Technology Data Exchange (ETDEWEB)

    Brodie, Brad [Denso International America, Incorporated, Southfield, MI (United States)

    2015-09-30

    The objective of this project is research, development and demonstration of innovative thermal management concepts that reduce the cell or battery weight, complexity (component count) and/or cost by at least 20%. The project addresses two issues that are common problems with current state of the art lithium ion battery packs used in vehicles; low power at cold temperatures and reduced battery life when exposed to high temperatures. Typically, battery packs are “oversized” to satisfy the two issues mentioned above. The first phase of the project was spent making a battery pack simulation model using AMEsim software. The battery pack used as a benchmark was from the Fiat 500EV. FCA and NREL provided vehicle data and cell data that allowed an accurate model to be created that matched the electrical and thermal characteristics of the actual battery pack. The second phase involved using the battery model from the first phase and evaluate different thermal management concepts. In the end, a gas injection heat pump system was chosen as the dedicated thermal system to both heat and cool the battery pack. Based on the simulation model. The heat pump system could use 50% less energy to heat the battery pack in -20°C ambient conditions, and by keeping the battery cooler at hot climates, the battery pack size could be reduced by 5% and still meet the warranty requirements. During the final phase, the actual battery pack and heat pump system were installed in a test bench at DENSO to validate the simulation results. Also during this phase, the system was moved to NREL where testing was also done to validate the results. In conclusion, the heat pump system can improve “fuel economy” (for electric vehicle) by 12% average in cold climates. Also, the battery pack size, or capacity, could be reduced 5%, or if pack size is kept constant, the pack life could be increased by two years. Finally, the total battery pack and thermal system cost could be reduced 5% only if the

  1. The Dental Neglect Scale in adolescents

    Directory of Open Access Journals (Sweden)

    Johnson Elissa K

    2009-01-01

    Full Text Available Abstract Background Dental neglect has been found to be related to poor oral health, a tendency not to have had routine check-ups, and a longer period of time since the last dental appointment in samples of children and adults. The Dental Neglect Scale (DNS has been found to be a valid measure of dental neglect in samples of children and adults, and may be valid for adolescents as well. We administered the DNS to a sample of adolescents and report on the relationships between the DNS and oral health status, whether or not the adolescent has been to the dentist recently for routine check-ups, and whether or not the adolescent currently goes to a dentist. We also report the internal and test-retest reliabilities of the DNS in this sample, as well as the results of an exploratory factor analysis. Methods One hundred seventeen adolescents from seven youth groups in the Seattle-Tacoma metropolitan area (Washington State, U.S. completed the DNS and indicated whether they currently go to a dentist, while parents indicated whether the adolescent had a check-up in the previous three years. Adolescents also received a dental screening. Sixty six adolescents completed the questionnaire twice. T-tests were used to compare DNS scores of adolescents who have visible caries or not, adolescents who have had a check-up in the past three years or not, and adolescents who currently go to a dentist or not. Internal reliability was measured by Cronbach's alpha, and test-rest reliability was measured by intra-class correlation. Factor analysis (Varimax rotation was used to examine the factor structure. Results In each comparison, significantly higher DNS scores were observed in adolescents with visible caries, who have not had a check-up in the past three years, or who do not go to a dentist (all p values Conclusion The DNS appears to operate similarly in this sample of adolescents as it has in other samples of children and adults.

  2. Online Estimation of Peak Power Capability of Li-Ion Batteries in Electric Vehicles by a Hardware-in-Loop Approach

    Directory of Open Access Journals (Sweden)

    Fengchun Sun

    2012-05-01

    Full Text Available Battery peak power capability estimations play an important theoretical role for the proper use of the battery in electric vehicles. To address the failures in relaxation effects and real-time ability performance, neglecting the battery’s design limits and other issues of the traditional peak power capability calculation methods, a new approach based on the dynamic electrochemical-polarization (EP battery model, taking into consideration constraints of current, voltage, state of charge (SoC and power is proposed. A hardware-in-the-loop (HIL system is built for validating the online model-based peak power capability estimation approach of batteries used in hybrid electric vehicles (HEVs and a HIL test based on the Federal Urban Driving Schedules (FUDS is used to verify and evaluate its real-time computation performance, reliability and robustness. The results show the proposed approach gives a more accurate estimate compared with the hybrid pulse power characterization (HPPC method, avoiding over-charging or over-discharging and providing a powerful guarantee for the optimization of HEVs power systems. Furthermore, the HIL test provides valuable data and critical guidance to evaluate the accuracy of the developed battery algorithms.

  3. Battery Calendar Life Estimator Manual Modeling and Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; Ira Bloom; Ed Thomas; Vince Battaglia

    2012-10-01

    The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.

  4. Optimal Switching Table-Based Sliding Mode Control of an Energy Recovery Li-Ion Power Accumulator Battery Pack Testing System

    Directory of Open Access Journals (Sweden)

    Kil To Chong

    2013-10-01

    Full Text Available The main objective of the present work is to apply a sliding mode controller (SMC to medium voltage and high power output energy recovery Li-ion power accumulator battery pack testing systems (ERLPABTSs, which are composed of a three-level neutral-point-clamped (NPC three-phase voltage source inverter (VSI and a two-level buck-boost converter without an isolating transformer. An inner current decoupled control scheme for the aforementioned system is proposed and two sliding mode planes for active and reactive current control are designed based on the control scheme. An optimized switching table for current convergence is used according to the error sign of the equivalent input voltage and feedback voltage. The proposed ERLPABTS could be used to integrate discharging energy into the power grid when performing high accuracy current testing. The active and reactive power references for the grid-connected inverter are determined based on the discharging energy from the DC-DC converter. Simulations and experiments on a laboratory hardware platform using a 175 kW insulated gate bipolar transistor (IGBT-based ERLPABTS have been implemented and verified, and the performance is found satisfactory and superior to conventional ERLPABPTS.

  5. Does Neglect Moderate the Impact of an Efficacious Preventive Intervention for Maltreated Children in Foster Care?

    Science.gov (United States)

    Taussig, Heather N.; Culhane, Sara E.; Garrido, Edward; Knudtson, Michael D.; Petrenko, Christie L. M.

    2015-01-01

    Physically neglected youth are at increased risk for mental health problems, but there are few interventions that have demonstrated efficacy in reducing mental health symptoms for this vulnerable population. The Fostering Healthy Futures (FHF) program, which consists of mentoring and skills groups, was developed for preadolescent youth in foster care. In a published randomized controlled trial with 156 youth, FHF demonstrated positive impacts on mental health functioning. The current study sought to determine whether FHF might be particularly effective in ameliorating the impact of neglectful family environments. Because it was not possible to isolate a neglected-only subgroup, as most children with physical neglect histories had experienced other types of maltreatment, we tested the hypothesis that intervention effects would be stronger among children with more severe physical neglect. Findings did not support this hypothesis, however, as severity of physical neglect did not significantly moderate the impact of the intervention on psychosocial outcomes PMID:23076837

  6. Dysconnection of right parietal and frontal cortex in neglect syndrome

    DEFF Research Database (Denmark)

    Dietz, Martin; Nielsen, Jørgen Feldbæk; Roepstorff, Andreas

    2017-01-01

    network, rather than a disruption of computation in any particular brain region. To test this hypothesis, we used Bayesian analysis of effective connectivity based on electroencephalographic recordings in patients with left-sided neglect after a right-hemisphere lesion. While age-matched healthy controls...

  7. The Neglected Situation: Assessment Performance and Interaction in Context

    Science.gov (United States)

    Maddox, Bryan

    2015-01-01

    Informed by Goffman's influential essay on "The neglected situation" this paper examines the contextual and interactive dimensions of performance in large-scale educational assessments. The paper applies Goffman's participation framework and associated theory in linguistic anthropology to examine how testing situations are framed and…

  8. Child Abuse and Neglect: Training Needs of Student Teachers

    Science.gov (United States)

    McKee, Bronagh E.; Dillenburger, Karola

    2009-01-01

    Increasing awareness of child abuse and neglect (CAN) raises questions about how well teachers are prepared for their role in child protection. This paper assesses and differentiates training needs of first-year students (n = 216) in Northern Ireland. Multiple-choice tests were used to assess knowledge of CAN statistics; recognising and reporting;…

  9. Computer Aided Battery Engineering Consortium

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad

    2016-06-07

    A multi-national lab collaborative team was assembled that includes experts from academia and industry to enhance recently developed Computer-Aided Battery Engineering for Electric Drive Vehicles (CAEBAT)-II battery crush modeling tools and to develop microstructure models for electrode design - both computationally efficient. Task 1. The new Multi-Scale Multi-Domain model framework (GH-MSMD) provides 100x to 1,000x computation speed-up in battery electrochemical/thermal simulation while retaining modularity of particles and electrode-, cell-, and pack-level domains. The increased speed enables direct use of the full model in parameter identification. Task 2. Mechanical-electrochemical-thermal (MECT) models for mechanical abuse simulation were simultaneously coupled, enabling simultaneous modeling of electrochemical reactions during the short circuit, when necessary. The interactions between mechanical failure and battery cell performance were studied, and the flexibility of the model for various batteries structures and loading conditions was improved. Model validation is ongoing to compare with test data from Sandia National Laboratories. The ABDT tool was established in ANSYS. Task 3. Microstructural modeling was conducted to enhance next-generation electrode designs. This 3- year project will validate models for a variety of electrodes, complementing Advanced Battery Research programs. Prototype tools have been developed for electrochemical simulation and geometric reconstruction.

  10. Evaluation of a new battery of toxicity tests for boreal forest soils: assessment of the impact of hydrocarbons and salts.

    Science.gov (United States)

    Princz, Juliska I; Moody, Mary; Fraser, Christopher; Van der Vliet, Leana; Lemieux, Heather; Scroggins, Rick; Siciliano, Steven D

    2012-04-01

    The ability to assess the toxic potential of soil contamination within boreal regions is currently limited to test species representative of arable lands. This study evaluated the use of six boreal plant species (Pinus banksiana, Picea glauca, Picea mariana, Populus tremuloides, Calamagrostis Canadensis, and Solidago canadensis) and four invertebrate species (Dendrodrilus rubidus, Folsomia nivalis, Proisotoma minuta, and Oppia nitens) and compared their performance to a suite of standard agronomic soil test species using site soils impacted by petroleum hydrocarbon (PHC) and salt contamination. To maintain horizon-specific differences, individual soil horizons were collected from impacted sites and relayered within the test vessels. Use of the boreal species was directly applicable to the assessment of the contaminated forest soils and, in the case of the hydrocarbon-impacted soil, demonstrated greater overall sensitivity (25th percentile of estimated species sensitivity distribution [ESSD25] = 5.6% contamination: 10,600 mg/kg fraction 3 [F3; equivalent hydrocarbon range of >C16 to C34] Of/Oh horizon, and 270 mg/kg F3 Ahg horizon) relative to the standard test species (ESSD25 = 23% contamination: 44,000 mg/kg F3 Of/Oh horizon, and 1,100 mg/kg F3 Ahg horizon). For salinity, there was no difference between boreal and standard species with a combined ESSD25 = 2.3%, equating to 0.24 and 0.25 dS/m for the Ah and Ck horizons. The unequal distribution of soil invertebrates within the layered test vessels can confound test results and the interpretation of the toxic potential of a site. The use of test species relevant to boreal eco-zones strengthens the applicability of the data in support of realistic ecological risk assessments applicable to the boreal regions. Copyright © 2012 SETAC.

  11. Alkaline battery operational methodology

    Science.gov (United States)

    Sholklapper, Tal; Gallaway, Joshua; Steingart, Daniel; Ingale, Nilesh; Nyce, Michael

    2016-08-16

    Methods of using specific operational charge and discharge parameters to extend the life of alkaline batteries are disclosed. The methods can be used with any commercial primary or secondary alkaline battery, as well as with newer alkaline battery designs, including batteries with flowing electrolyte. The methods include cycling batteries within a narrow operating voltage window, with minimum and maximum cut-off voltages that are set based on battery characteristics and environmental conditions. The narrow voltage window decreases available capacity but allows the batteries to be cycled for hundreds or thousands of times.

  12. Long-Term Efficacy of Prism Adaptation on Spatial Neglect: Preliminary Results on Different Spatial Components

    Directory of Open Access Journals (Sweden)

    Maria Luisa Rusconi

    2012-01-01

    Full Text Available This study describes the long-term effectiveness on spatial neglect recovery of a 2-week treatment based on prism adaptation (PA. Seven right-brain-damaged patients affected by chronic neglect were evaluated before, after two weeks of the PA treatment and at a follow-up (variable between 8 and 30 months after the end of PA. Neglect evaluation was performed by means of BIT (conventional and behavioral, Fluff Test, and Comb and Razor Test. The results highlight an improvement, after the PA training, in both tasks performed using the hand trained in PA treatment and in behavioral tasks not requiring a manual motor response. Such effects extend, even if not significantly, to all BIT subtests. These results support previous findings, showing that PA improves neglect also on imagery tasks with no manual component, and provide further evidence for long-lasting efficacy of PA training. Dissociations have been found with regard to PA efficacy on peripersonal, personal, and representational neglect, visuospatial agraphia and neglect dyslexia. In particular, we found no significant differences between the pre-training and post-training PA session in personal neglect measures, and a poor recovery of neglect dyslexia after PA treatment. The recruitment of a larger sample could help to confirm the effectiveness of the prismatic lenses with regard to the different clinical manifestations of spatial neglect.

  13. Right hemispatial ipsilesional neglect with chronic right hemisphere strokes.

    Science.gov (United States)

    Williamson, John B; Lamb, Damon G; Burtis, D Brandon; Haque, Salsabil; M Zilli, Eduardo; Kesayan, Tigran; Harciarek, Michal; Heilman, Kenneth M

    2018-05-01

    Patients who present with spatial neglect after stroke often perform normally on tests for neglect after a few weeks. Whereas tests for neglect are often performed directly in front of a patient, in their actual environments many important stimuli may be present within their left or right hemispace. The presence and severity of neglect often depends on the hemisphere injured. It is possible, in chronic stroke, for spatial judgments to be influenced by an interaction of stroke laterality and the spatial location of stimuli. The objective of this study was to learn if unilateral hemispheric chronic strokes contribute to a spatial bias with laterally presented stimuli. There were 70 participants, 62 with unilateral chronic strokes (>6 months post onset) including 35 with left hemisphere damage (LHD), 27 with right hemisphere damage (RHD), and 8 demographically similar people without history of stroke. Participants were asked to bisect 300 lines presented with distractors on the left, right, or both sides of the line, or no distractor, on a touch-screen monitor in right, center or left hemispace. There was a significant interaction between the side of the hemispheric lesion and the side of the body where these lines were presented. Specifically, in right space, patients with RHD deviated leftward in comparison to the other groups. Furthermore, there was an interaction between group and distractor induced bias. All three groups approached the left distractor, and the patients with LHD also approached the right distractor. Although spatial neglect is more severe in contralesional than ipsilesional hemispace in the period immediately following a stroke, over time patients with RHD may develop ipsilesional neglect that is more severe in ipsilesional than contralesional space. The mechanism underlying this bias is not known and may be related to attempted compensation or the development of a contralateral attentional/intentional grasp.

  14. DOE battery program for weapon applications

    Science.gov (United States)

    Clark, R. P.; Baldwin, A. R.

    This report discusses the Department of Energy (DOE) Weapons Battery program which originates from Sandia National Laboratories (SNL) and involves activities ranging from research, design and development to testing, consulting, and production support. The primary customer is the DOE/Office of Defense Programs, although work is also done for various Department of Defense agencies and their contractors. The majority of the SNL activities involve thermal battery (TB) and lithium ambient temperature battery (LAMB)technologies. Smaller efforts are underway in the areas of silver oxide/zinc and nickel oxide/cadmium batteries as well as double layer capacitors.

  15. Multicell LiSOCl sub 2 reserve battery

    Science.gov (United States)

    Baldwin, A. R.; Garoutte, K. F.

    Recent development work on reverse lithium thionyl chloride (RLTC) batteries at SNLA and Honeywell has included safety and performance evaluations. The RLTC battery is being considered for applications that were traditionally fulfilled by state-of-the-art thermal batteries and reserve silver oxide zinc electrochemical systems. These applications typically demand a reserve battery having a rapid voltage rise, high reliability, operational safety and useful active lifetime ranging from minutes to hours. The RLTC work reported here was directed toward a power battery capable of meeting or exceeding the design requirements. Performance and safety test data indicate that the RLTC battery may be better suited than thermal batteries for some long-life applications. A comparison between Li(Si)/FeS2 thermal battery and an RLTC battery, both of which were designed to fulfill the requirements is presented.

  16. Sealed metal-hydride batteries for aerospace applications

    Science.gov (United States)

    Coates, Dwaine; Wright, R. D.

    Nickel and silver-metal hydride batteries are being developed for aerospace applications by Eagle-Picher. Metal hydride batteries offer a number of advantages over other aerospace battery systems. Nickel-metal hydride batteries have twice the gravimetric energy density of nickel-cadmium batteries and twice the volumetric energy density of nickel-hydrogen batteries. Silver-metal hydride batteries have the potential of three times the energy density of nickel-metal hydride. Aerospace metal hydride batteries are hermetically sealed, operate at low pressure and are prismatic in geometry. They exhibit excellent overcharge and overdischarge capability. The objective of current programs at Eagle-Picher is to develop high energy density, long cycle life metal-hydride batteries for the aerospace market and to establish a testing database to support future applications.

  17. Object-based neglect in number processing

    Science.gov (United States)

    2013-01-01

    Recent evidence suggests that neglect patients seem to have particular problems representing relatively smaller numbers corresponding to the left part of the mental number line. However, while this indicates space-based neglect for representational number space little is known about whether and - if so - how object-based neglect influences number processing. To evaluate influences of object-based neglect in numerical cognition, a group of neglect patients and two control groups had to compare two-digit numbers to an internally represented standard. Conceptualizing two-digit numbers as objects of which the left part (i.e., the tens digit should be specifically neglected) we were able to evaluate object-based neglect for number magnitude processing. Object-based neglect was indicated by a larger unit-decade compatibility effect actually reflecting impaired processing of the leftward tens digits. Additionally, faster processing of within- as compared to between-decade items provided further evidence suggesting particular difficulties in integrating tens and units into the place-value structure of the Arabic number system. In summary, the present study indicates that, in addition to the spatial representation of number magnitude, also the processing of place-value information of multi-digit numbers seems specifically impaired in neglect patients. PMID:23343126

  18. Open Source Intelligence - Doctrine's Neglected Child

    National Research Council Canada - National Science Library

    Pham, Tuan

    2003-01-01

    .... The causes of this neglect are many, ranging from previously mentioned predisposition toward classified intelligence sources to the technical challenge of information excess that overloads the users...

  19. Elder self-neglect: research and practice

    Directory of Open Access Journals (Sweden)

    Dong XQ

    2017-06-01

    Full Text Available XinQi Dong Rush Institute for Healthy Aging, Rush University Medical Center, Chicago, IL, USA Abstract: Elder self-neglect is a global public health and human rights issue that threatens older people’s health and safety. It commonly refers to refusal or failure to provide oneself with care and protection in areas of food, water, clothing, hygiene, medication, living environments, and safety precautions. While prevalent, the status of self-neglecting individuals remains largely unclear, in particular within community-dwelling populations. By reviewing the epidemiology of elder self-neglect (definition, prevalence, risk factors, and consequences to date, the present paper identifies key research gaps such as methodological inconsistency in case identification and measurement, and study designs that are inadequate to determine risk factors of self-neglect. More importantly, in light of the rapidly growing older population, relevant stakeholders (researchers, healthcare providers, social service providers, legal professionals, community organizations, and policymakers must be prepared for an expected increasing number of self-neglect cases and enlarging scope of the problem. Hence, in this article, I present an overview regarding the management issues of elderly self-neglect related to the detection, assessment, reporting and referral, and decision-making capacity. Based on the current literature, the paper is aimed to explore the present knowledge and challenges, and how they can pave the way for solutions to self-neglect research, practice, and policy. Keywords: elderly self-neglect, elder abuse, self-neglect future directions 

  20. Reporting Fatal Neglect in Child Death Review.

    Science.gov (United States)

    Scott, Debbie

    2018-01-01

    Child death reviews are conducted with the aim of preventing child deaths however, definitions, inclusion criteria for the review of child deaths and reporting practices vary across Child Death Review Teams (CDRTs). This article aims to identify a common context and understanding of fatal neglect reporting by reviewing definitional issues of fatal neglect and comparing reporting practice across a number of CDRTs. Providing a consistent context for identifying and reporting neglect-related deaths may improve the understanding of the impact of fatal neglect and the risk factors associated with it and therefore, improve the potential of CDRT review to inform prevention programs, policies, and procedures.

  1. 10 CFR Appendix Y to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Battery Chargers

    Science.gov (United States)

    2010-01-01

    ... factor and frequency spectrum in its measurement of the UUT input current.” 4. Test Measurement: (a... through a detachable AC power cord, then only the cord will remain connected to mains, and standby mode power consumption will equal that of the AC power cord (i.e., zero watts). (4) Finally, if the product...

  2. Fine-Tuning Cross-Battery Assessment Procedures: After Follow-Up Testing, Use All Valid Scores, Cohesive or Not

    Science.gov (United States)

    Schneider, W. Joel; Roman, Zachary

    2018-01-01

    We used data simulations to test whether composites consisting of cohesive subtest scores are more accurate than composites consisting of divergent subtest scores. We demonstrate that when multivariate normality holds, divergent and cohesive scores are equally accurate. Furthermore, excluding divergent scores results in biased estimates of…

  3. The BACHD Rat Model of Huntington Disease Shows Specific Deficits in a Test Battery of Motor Function

    Directory of Open Access Journals (Sweden)

    Giuseppe Manfré

    2017-11-01

    Full Text Available Rationale: Huntington disease (HD is a progressive neurodegenerative disorder characterized by motor, cognitive and neuropsychiatric symptoms. HD is usually diagnosed by the appearance of motor deficits, resulting in skilled hand use disruption, gait abnormality, muscle wasting and choreatic movements. The BACHD transgenic rat model for HD represents a well-established transgenic rodent model of HD, offering the prospect of an in-depth characterization of the motor phenotype.Objective: The present study aims to characterize different aspects of motor function in BACHD rats, combining classical paradigms with novel high-throughput behavioral phenotyping.Methods: Wild-type (WT and transgenic animals were tested longitudinally from 2 to 12 months of age. To measure fine motor control, rats were challenged with the pasta handling test and the pellet reaching test. To evaluate gross motor function, animals were assessed by using the holding bar and the grip strength tests. Spontaneous locomotor activity and circadian rhythmicity were assessed in an automated home-cage environment, namely the PhenoTyper. We then integrated existing classical methodologies to test motor function with automated home-cage assessment of motor performance.Results: BACHD rats showed strong impairment in muscle endurance at 2 months of age. Altered circadian rhythmicity and locomotor activity were observed in transgenic animals. On the other hand, reaching behavior, forepaw dexterity and muscle strength were unaffected.Conclusions: The BACHD rat model exhibits certain features of HD patients, like muscle weakness and changes in circadian behavior. We have observed modest but clear-cut deficits in distinct motor phenotypes, thus confirming the validity of this transgenic rat model for treatment and drug discovery purposes.

  4. Standard procedure for testing acute toxic effects on bioluminescent bacteria; Saggio di tossicita` acuta con batteri bioluminescenti

    Energy Technology Data Exchange (ETDEWEB)

    Guzzella, L. [CNR, Brugherio, Milan (Italy). Istituto di Ricerca Sulle Acque

    1996-06-01

    A standardized method for the determination of 15-30 min toxicity of `Vibrio fisheri` bioluminescent bacteria is evaluated. The proposed method can be applied for the analysis of liquid (superficial and drinking waters, eluates and wastes) and solid (sediments and muds) samples and permits the quantification of the EC50 and EC20 values and of the no-effective sample dilution. The results of a interlaboratory ring tests conducted with reference substances are illustrated.

  5. Convergent and discriminant validity of the Immediate Postconcussion Assessment and Cognitive Testing Battery (ImPACT) in young athletes.

    Science.gov (United States)

    Koehl, Lisa M; Walls, Brittany D; Brothers, Stacey L; Morris, Sarah N; Glueck, Amanda C; Schmitt, Frederick A; Berry, David T R; Han, Dong Y

    2018-02-21

    Sports concussions are recognized as significant injuries among young athletes. Research demonstrates that return-to-play prior to becoming asymptomatic has significant repercussions including sustained cognitive deficits. Many programs have begun to use computerized testing rather than traditional neuropsychological tests to (a) determine baseline performance, (b) track symptoms, and (c) measure symptoms following concussion. Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is one such tool. The current study examined ImPACT's convergent and discriminant validity by comparing scores from sports-related concussion athletes (SRC) to those from nonconcussed controls (CTL). SRC included 29 athletes, ages 12-16, referred for neuropsychological assessment following sports-related concussions. CTL included 25 healthy athletes, ages 12-16, who were concussion-free in the past year. Overall, results showed general support for ImPACT, when used to screen cognition. In fact, all ImPACT domains successfully differentiated between SRC and CTL athletes. Evidence supporting appropriate convergent validity was best for the Visual Memory domain. Further, ImPACT domains demonstrated variable discriminant validity. Overall examination of validity demonstrated that ImPACT has some weaknesses but may have utility in detecting postconcussion cognitive impairment.

  6. Cognitive function in patients with newly diagnosed HIV infection in a tertiary health facility in south - west Nigeria: Assessment using computer-assisted neuropsychological test battery.

    Science.gov (United States)

    Sunmonu, Taofiki A; A Ogunrin, Olubunmi; Imarhiagbe, Frank A; Owolabi, Lukman F; Komolafe, Morenikeji A; Llesanmi, Olayinka S

    2016-06-01

    Cognitive dysfunction is common among patients with human immunodeficiency virus (HIV) infection however there are few reports from sub-Saharan Africa. We studied fifty seropositive patients with human immunodeficiency virus (HIV) infection along with fifty matched seronegative control. Medical history taking and general physical and neurological examinations were done for all study participants. Laboratory evaluations and chest X-ray were done for all the patients. The cognitive function was done with the aid of 'Fepsy' automated test battery for all the study participants. The data was analyzed with statistical package for social sciences software version 21.0 (SPSS Chicago IL). About 70% of the HIV patients were in advanced disease stage. The auditory and visual reaction times, binary choice reaction times, and computerized visual scanning task time were more prolonged in the HIV group (p  0.05). Among the patients with HIV infection, the presence of anemia and central nervous system toxoplasmosis infection was associated with prolonged auditory and visual reaction times. There was a high rate of cognitive dysfunction in patients with HIV infection in this study.

  7. Field tests experience from 1.6MW/400kWh Li-ion battery energy storage system providing primary frequency regulation service

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Ioan; Stan, Ana-Irina

    2013-01-01

    Lithium-ion battery energy storage systems (BESSs) represent suitable alternatives to conventional generating units for providing primary frequency regulation on the Danish market. This paper presents aspects concerning the operation of the BESSs in the Danish energy market while providing upwards...... on the BESS demonstrator located in Western Denmark and initial results are introduced and discussed. These measurements can be used to validate models for battery ageing during realistic operation or to develop the diagnostic tools for the BESS....

  8. Filarial hydrocele: a neglected condition of a neglected tropical disease.

    Science.gov (United States)

    Otabil, Kenneth Bentum; Tenkorang, Seth Boateng

    2015-03-18

    Filarial hydrocele is the most common chronic manifestation of lymphatic filariasis (LF) and poses a major public health burden to several filarial endemic countries. This review highlights the socio-economic impact of the disease, the role of the immune system in hydrocele development, current diagnostic approaches, and the control and management of filarial hydrocele. In the quest to facilitate the global effort to eliminate filarial hydrocele as a neglected tropical disease, a more comprehensive understanding of the mechanisms underlying the pathogenesis and development of the condition is important. In general, success has been achieved using annual treatment with ivermectin, but much remains to be done, particularly with late-stage infected individuals where surgery remains the only option. Studies have successfully demonstrated that inhibition of embryogenesis in adult female worms occurs after weeks of tetracycline treatment. Even more intriguing was the observation that the Wolbachia endosymbionts potently induce proinflammatory cytokines such as tumor necrosis factors (TNFs) and vascular endothelial growth factors (VEGFs), which are crucial for the development of filarial hydrocele. Furthermore, reports from human studies show that doxycycline treatment significantly ameliorates filarial hydrocele and markedly reverses early-stage filarial hydrocele. However, with the enormous challenges that face LF elimination such as global funding, logistics, civil wars, and drug resistance, a more relentless and collective approach from local governments as well as other stakeholders is needed to accelerate the fight against filarial hydrocele if the goal to eliminate it by 2020 is be to achieved.

  9. Child Abuse and Neglect and Subclinical Cardiovascular Disease Among Midlife Women.

    Science.gov (United States)

    Thurston, Rebecca C; Chang, Yuefang; Barinas-Mitchell, Emma; von Känel, Roland; Jennings, J Richard; Santoro, Nanette; Landsittel, Doug P; Matthews, Karen A

    2017-05-01

    A childhood history of abuse or neglect may be associated with elevated adult cardiovascular disease (CVD) risk. No studies have examined associations between child abuse/neglect and subclinical CVD using a validated measure of abuse and neglect. We hypothesized that midlife women with a history of childhood abuse or neglect would have increased subclinical CVD beyond standard CVD risk factors. We tested moderation of associations by sleep, hot flashes, and race/ethnicity. Two hundred ninety-five midlife women completed the Child Trauma Questionnaire, physiologic hot flash and actigraphic sleep monitoring, blood draw, and carotid ultrasound (intima media thickness [IMT]; plaque). Relations between abuse/neglect and outcomes were tested in linear regression models adjusting for demographic, psychosocial, and CVD risk factors. Interactions with sleep, hot flashes, and race/ethnicity were tested. Forty-five percent of women reported a history of child abuse or neglect. Women with any child abuse or neglect had higher IMT [b(SE) = .039 (.011), p = .001] and carotid plaque [odds ratio (95% [CI] = 1.95 [1.15-3.33]); p = .014] than nonabused/neglected women. Furthermore, physical abuse, emotional abuse, and emotional neglect were associated with higher subclinical CVD. Sexual abuse was associated with higher IMT among nonwhite women. Interactions with sleep time and sleep hot flashes (p values neglect history was observed primarily among women sleeping less than 6 hours/night or with sleep hot flashes. A history of child abuse or neglect is associated with higher subclinical CVD in women, particularly when paired with short sleep or hot flashes. Findings underscore the importance of childhood adversity in midlife women's CVD risk.

  10. Incorporation of gypsum waste in ceramic block production: Proposal for a minimal battery of tests to evaluate technical and environmental viability of this recycling process.

    Science.gov (United States)

    Godinho-Castro, Alcione P; Testolin, Renan C; Janke, Leandro; Corrêa, Albertina X R; Radetski, Claudemir M

    2012-01-01

    Civil engineering-related construction and demolition debris is an important source of waste disposed of in municipal solid waste landfills. After clay materials, gypsum waste is the second largest contributor to the residential construction waste stream. As demand for sustainable building practices grows, interest in recovering gypsum waste from construction and demolition debris is increasing, but there is a lack of standardized tests to evaluate the technical and environmental viability of this solid waste recycling process. By recycling gypsum waste, natural deposits of gypsum might be conserved and high amounts of the waste by-product could be reused in the civil construction industry. In this context, this paper investigates a physical property (i.e., resistance to axial compression), the chemical composition and the ecotoxicological potential of ceramic blocks constructed with different proportions of clay, cement and gypsum waste, and assesses the feasibility of using a minimal battery of tests to evaluate the viability of this recycling process. Consideration of the results for the resistance to axial compression tests together with production costs revealed that the best formulation was 35% of plastic clay, 35% of non-plastic clay, 10% of Portland cement and 20% of gypsum waste, which showed a mean resistance of 4.64MPa. Energy dispersive X-ray spectrometry showed calcium and sulfur to be the main elements, while quartz, gypsum, ettringite and nacrite were the main crystalline compounds found in this formulation. Ecotoxicity tests showed that leachate from this formulation is weakly toxic toward daphnids and bacteria (EC(20%)=69.0 and 75.0, respectively), while for algae and fish the leachate samples were not toxic at the EC(50%) level. Overall, these results show that the addition of 20% of gypsum waste to the ceramic blocks could provide a viable substitute for clay in the ceramics industry and the tests applied in this study proved to be a useful tool

  11. Relationship between visuospatial neglect and kinesthetic deficits after stroke.

    Science.gov (United States)

    Semrau, Jennifer A; Wang, Jeffery C; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2015-05-01

    After stroke, visuospatial and kinesthetic (sense of limb motion) deficits are common, occurring in approximately 30% and 60% of individuals, respectively. Although both types of deficits affect aspects of spatial processing necessary for daily function, few studies have investigated the relationship between these 2 deficits after stroke. We aimed to characterize the relationship between visuospatial and kinesthetic deficits after stroke using the Behavioral Inattention Test (BIT) and a robotic measure of kinesthetic function. Visuospatial attention (using the BIT) and kinesthesia (using robotics) were measured in 158 individuals an average of 18 days after stroke. In the kinesthetic matching task, the robot moved the participant's stroke-affected arm at a preset direction, speed, and magnitude. Participants mirror-matched the robotic movement with the less/unaffected arm as soon as they felt movement in their stroke affected arm. We found that participants with visuospatial inattention (neglect) had impaired kinesthesia 100% of the time, whereas only 59% of participants without neglect were impaired. For those without neglect, we observed that a higher percentage of participants with lower but passing BIT scores displayed impaired kinesthetic behavior (78%) compared with those participants who scored perfect or nearly perfect on the BIT (49%). The presence of visuospatial neglect after stroke is highly predictive of the presence of kinesthetic deficits. However, the presence of kinesthetic deficits does not necessarily always indicate the presence of visuospatial neglect. Our findings highlight the importance of assessment and treatment of kinesthetic deficits after stroke, especially in patients with visuospatial neglect. © The Author(s) 2014.

  12. Characterization of Vanadium Flow Battery

    DEFF Research Database (Denmark)

    Bindner, Henrik W.; Krog Ekman, Claus; Gehrke, Oliver

    This report summarizes the work done at Risø-DTU testing a vanadium flow battery as part of the project “Characterisation of Vanadium Batteries” (ForskEl project 6555) with the partners PA Energy A/S and OI Electric A/S under the Danish PSO energy research program. A 15kW/120kWh vanadium battery...... has been installed as part of the distributed energy systems experimental facility, SYSLAB, at Risø DTU. A test programme has been carried out to get hands-on experience with the technology, to characterize the battery from a power system point of view and to assess it with respect to integration...... of wind energy in the Danish power system. The battery has been in operation for 18 months. During time of operation the battery has not shown signs of degradation of performance. It has a round-trip efficiency at full load of approximately 60% (depending on temperature and SOC). The sources of the losses...

  13. Neglecting Neglect: Some Thoughts about Children Who Have Lacked Good Input, and Are "Undrawn" and "Unenjoyed"

    Science.gov (United States)

    Music, Graham

    2009-01-01

    This paper looks at emotional neglect in the early years of life, and postulates some probable long-term sequelae of such neglect. It argues that there is a continuum of neglect; ranging from the severest form, as seen in institutional orphanages, to milder variations. A range of theoretical and research traditions, including developmental…

  14. Neglect Patients Exhibit Egocentric or Allocentric Neglect for the Same Stimulus Contingent upon Task Demands.

    Science.gov (United States)

    Leyland, Louise-Ann; Godwin, Hayward J; Benson, Valerie; Liversedge, Simon P

    2017-05-16

    Hemispatial Neglect (HN) is a failure to allocate attention to a region of space opposite to where damage has occurred in the brain, usually the left side of space. It is widely documented that there are two types of neglect: egocentric neglect (neglect of information falling on the individual's left side) and allocentric neglect (neglect of the left side of each object, regardless of the position of that object in relation to the individual). We set out to address whether neglect presentation could be modified from egocentric to allocentric through manipulating the task demands whilst keeping the physical stimulus constant by measuring the eye movement behaviour of a single group of neglect patients engaged in two different tasks (copying and tracing). Eye movements and behavioural data demonstrated that patients exhibited symptoms consistent with egocentric neglect in one task (tracing), and allocentric neglect in another task (copying), suggesting that task requirements may influence the nature of the neglect symptoms produced by the same individual. Different task demands may be able to explain differential neglect symptoms in some individuals.

  15. Comparison of cognitive functioning as measured by the Ruff Figural Fluency Test and the CogState computerized battery within the LifeLines Cohort Study.

    Science.gov (United States)

    Kuiper, Jisca S; Oude Voshaar, Richard C; Verhoeven, Floor E A; Zuidema, Sytse U; Smidt, Nynke

    2017-05-12

    The Ruff Figural Fluency Test (RFFT; a pencil and paper test) and the CogState (a computerized cognitive test battery) are well-validated and suitable tests to evaluate cognitive functioning in large observational studies at the population level. The LifeLines Cohort Study includes the RFFT as baseline measurement and incorporated the CogState as replacement for the RFFT at follow-up. It is unknown how these two tests relate to each other. Therefore, the aim of this study is to examine the correlation between the RFFT and the CogState and the impact of demographic characteristics on this association. A subcohort of the LifeLines Cohort Study, a large population based cohort study, participated in this study. Correlations between the RFFT and six subtasks of the CogState were examined. Subgroup analyses were performed to investigate the influence of age, education, and gender on the results. With sensitivity analyses we investigated the influence of computer experience and (physical) impairments. A total of 509 participants (mean age (SD): 53 years (14.6); range 18-87 years) participated in this study. All correlations between the RFFT and the CogState were statistically significant (except for the correlation between the RFFT error ratio and the CogState One Back Task), ranging from -0.39 to 0.28. Stratifying the analyses for age, education, and gender did not substantially affect our conclusions. Sensitivity analyses showed no substantial influence of level of computer experience or (physical) impairments. Correlations found in the present study were only weak to moderate, indicating that cognitive functioning measured by the RFFT does not measure the same components of cognitive functioning as six subtasks of the CogState. Computerized testing such as the CogState may be very well suited for large cohort studies to assess cognitive functioning in the general population and to identify cognitive changes as early as possible, as it is a less time- and labor

  16. Simulation and experimental study on lithium ion battery short circuit

    International Nuclear Information System (INIS)

    Zhao, Rui; Liu, Jie; Gu, Junjie

    2016-01-01

    Highlights: • Both external and internal short circuit tests were performed on Li-ion batteries. • An electrochemical–thermal model with an additional nail site heat source is presented. • The model can accurately simulate the temperature variations of non-venting batteries. • The model is reliable in predicting the occurrence and start time of thermal runaway. • A hydrogel cooling system proves its strength in preventing battery thermal runaway. - Abstract: Safety is the first priority in lithium ion (Li-ion) battery applications. A large portion of electrical and thermal hazards caused by Li-ion battery is associated with short circuit. In this paper, both external and internal short circuit tests are conducted. Li-ion batteries and battery packs of different capacities are used. The results indicate that external short circuit is worse for smaller size batteries due to their higher internal resistances, and this type of short can be well managed by assembling fuses. In internal short circuit tests, higher chance of failure is found on larger capacity batteries. A modified electrochemical–thermal model is proposed, which incorporates an additional heat source from nail site and proves to be successful in depicting temperature changes in batteries. Specifically, the model is able to estimate the occurrence and approximate start time of thermal runaway. Furthermore, the effectiveness of a hydrogel based thermal management system in suppressing thermal abuse and preventing thermal runaway propagation is verified through the external and internal short tests on batteries and battery packs.

  17. A proposed test battery and constellations of specific behavioral paradigms to investigate the behavioral phenotypes of transgenic and knockout mice.

    Science.gov (United States)

    Crawley, J N; Paylor, R

    1997-06-01

    Behavioral phenotyping of transgenic and knockout mice requires rigorous, formal analyses. Well-characterized paradigms can be chosen from the established behavioral neuroscience literature. This review describes (1) a series of neurological and neuropsychological tests which are effectively used as a first screen for behavioral abnormalities in mutant mice, and (2) a series of specific behavioral paradigms, clustered by category. Included are multiple paradigms for each category, including learning and memory, feeding, analgesia, aggression, anxiety, depression, schizophrenia, and drug abuse models. Examples are given from the experiences of the authors, in applying these experimental designs to transgenic and knockout mice. Extensive references for each behavioral paradigm are provided, to allow new investigators to access the relevant literature on behavioral methodology.

  18. Novel insights in the rehabilitation of neglect

    NARCIS (Netherlands)

    Kessel, M.E. van; Fasotti, L.

    2013-01-01

    Visuospatial neglect due to right hemisphere damage, usually a stroke, is a major cause of disability, impairing the ability to perform a whole range of everyday life activities. Conventional and long-established methods for the rehabilitation of neglect like visual scanning training, optokinetic

  19. Base Rates: Both Neglected and Intuitive

    Science.gov (United States)

    Pennycook, Gordon; Trippas, Dries; Handley, Simon J.; Thompson, Valerie A.

    2014-01-01

    Base-rate neglect refers to the tendency for people to underweight base-rate probabilities in favor of diagnostic information. It is commonly held that base-rate neglect occurs because effortful (Type 2) reasoning is required to process base-rate information, whereas diagnostic information is accessible to fast, intuitive (Type 1) processing…

  20. Hubble Space Telescope 2004 Battery Update

    Science.gov (United States)

    Hollandsworth, Roger; Armantrout, Jon; Whitt, Tom; Rao, Gopalakrishna M.

    2006-01-01

    Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Flight Center (MSFC), which is instrumented with individual cell voltage monitoring. The on-orbit HST batteries were manufactured on an expedited basis after the Challenger Shuttle Disaster in 1986. The original design called for the HST to be powered by six 50 Ah Nickel Cadmium batteries, which would have required a shuttle mission every 5 years for battery replacement. The decision to use NiH2 instead has resulted in a longer life battery set which was launched with HST in April 1990, with a design life of 7 years that has now exceeded 14+ years of orbital cycling. This chart details the specifics of the original HST NiH2 cell design. The HST replacement batteries for Service Mission 4, originally scheduled for Spring 2005, are currently in cold storage at NASA Goddard Space Flight Center (GSFC). The SM4 battery cells utilize slurry process electrodes having 80% porosity.

  1. Construct Validity of the Movement Assessment Battery for Children-Second Edition Test in Preschool Children with Respect to Age and Gender

    Directory of Open Access Journals (Sweden)

    Jakub Kokštejn

    2018-01-01

    Full Text Available BackgroundThe Movement Assessment Battery for Children-second edition (MABC-2 Age Band 1 is widely used to identify preschoolers with motor difficulties. Despite unsatisfactory construct validity of the original three-factor model, MABC-2 (manual dexterity, aiming and catching, and balance, previous research has not considered possible age and gender differences throughout the entire preschool period.AimThe aim of this study was to verify the construct validity of the MABC-2 Age Band 1 in a population of Czech preschoolers with respect to age and gender.MethodsUsing data from 510 Czech preschoolers (3–6 years; 4.9 ± 1.1 years, confirmatory factor analyses (CFA were used for each age category and gender.ResultsThe goodness-of-fit indices of CFA supported the original three-factor model of the MABC-2 only in 3- and 4-year-old children, and in boys (3–6 years. Low factor loadings and ceiling effects of several test items (Drawing Trail, Walking Heels Raised, and Jumping on Mats seem to be a probable cause of weak fit indices in 5- and 6-year-old children and in girls (3–6 years.ConclusionThese results suggest that the MABC-2 can be a valid tool for assessing motor development and identifying motor difficulties among 3- to 4-year olds, and generally fits better for preschool boys in the Czech Republic. However, in 5- to 6-year olds, ceiling effects and a low power of discrimination was found for the Drawing Trail, Walking Heels Raised, and Jumping on Mats tests. Therefore, the three-factor model is not appropriate for all preschoolers, and separate norms should be established for each age and gender.

  2. Construct Validity of the Movement Assessment Battery for Children-Second Edition Test in Preschool Children with Respect to Age and Gender.

    Science.gov (United States)

    Kokštejn, Jakub; Musálek, Martin; Tufano, James J

    2018-01-01

    The Movement Assessment Battery for Children-second edition (MABC-2) Age Band 1 is widely used to identify preschoolers with motor difficulties. Despite unsatisfactory construct validity of the original three-factor model, MABC-2 (manual dexterity, aiming and catching, and balance), previous research has not considered possible age and gender differences throughout the entire preschool period. The aim of this study was to verify the construct validity of the MABC-2 Age Band 1 in a population of Czech preschoolers with respect to age and gender. Using data from 510 Czech preschoolers (3-6 years; 4.9 ± 1.1 years), confirmatory factor analyses (CFA) were used for each age category and gender. The goodness-of-fit indices of CFA supported the original three-factor model of the MABC-2 only in 3- and 4-year-old children, and in boys (3-6 years). Low factor loadings and ceiling effects of several test items (Drawing Trail, Walking Heels Raised, and Jumping on Mats) seem to be a probable cause of weak fit indices in 5- and 6-year-old children and in girls (3-6 years). These results suggest that the MABC-2 can be a valid tool for assessing motor development and identifying motor difficulties among 3- to 4-year olds, and generally fits better for preschool boys in the Czech Republic. However, in 5- to 6-year olds, ceiling effects and a low power of discrimination was found for the Drawing Trail, Walking Heels Raised, and Jumping on Mats tests. Therefore, the three-factor model is not appropriate for all preschoolers, and separate norms should be established for each age and gender.

  3. The Computational Anatomy of Visual Neglect.

    Science.gov (United States)

    Parr, Thomas; Friston, Karl J

    2018-02-01

    Visual neglect is a debilitating neuropsychological phenomenon that has many clinical implications and-in cognitive neuroscience-offers an important lesion deficit model. In this article, we describe a computational model of visual neglect based upon active inference. Our objective is to establish a computational and neurophysiological process theory that can be used to disambiguate among the various causes of this important syndrome; namely, a computational neuropsychology of visual neglect. We introduce a Bayes optimal model based upon Markov decision processes that reproduces the visual searches induced by the line cancellation task (used to characterize visual neglect at the bedside). We then consider 3 distinct ways in which the model could be lesioned to reproduce neuropsychological (visual search) deficits. Crucially, these 3 levels of pathology map nicely onto the neuroanatomy of saccadic eye movements and the systems implicated in visual neglect. © The Author 2017. Published by Oxford University Press.

  4. Liver Flukes: the Malady Neglected

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jae Hoon [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    Liver fluke disease is a chronic parasitic inflammatory disease of the bile ducts. Infection occurs through ingestion of fluke-infested, fresh-water raw fish. The most well-known species that cause human infection are Clonorchis sinensis, Opisthorchis viverrini and Opisthorchis felineus. Adult flukes settle in the small intrahepatic bile ducts and then they live there for 20-30 years. The long-lived flukes cause long-lasting chronic inflammation of the bile ducts and this produces epithelial hyperplasia, periductal fibrosis and bile duct dilatation. The vast majority of patients are asymptomatic, but the patients with heavy infection suffer from lassitude and nonspecific abdominal complaints. The complications are stone formation, recurrent pyogenic cholangitis and cholangiocarcinoma. Approximately 35 million people are infected with liver flukes throughout the world and the exceptionally high incidence of cholangiocarcinoma in some endemic areas is closely related with a high prevalence of liver fluke infection. Considering the impact of this food-borne malady on public health and the severe possible clinical consequences, liver fluke infection should not be forgotten or neglected.

  5. An introduction to neglected disasters

    Directory of Open Access Journals (Sweden)

    Ben Wisner

    2009-04-01

    Full Text Available This theme issue of Jàmbá takes up the question of neglected disasters. It is an important topic because the world is changing, disasters are changing, and theory is changing. All these changes call for a re-assessment of why some human suffering and social disruption receive attention from authorities, donors, researchers and the media, while some does not. Recent progress in both development studies and disaster studies provides tools for answering this question. Development and disaster studies date in their current forms to ways of thinking that were current in academic and policy circles in the late 1950s and 1960s. At that time the world was recovering from world war and former colonies of Europe were gaining independence. It was a world in which (with some exceptions conflict was held in check in an uneasy cold war balance. It was also a world where a growing UN system held the promise of meeting humanitarian needs when they arose. That world is no more. ‘Development’ has changed.

  6. Influence of Battery Parametric Uncertainties on the State-of-Charge Estimation of Lithium Titanate Oxide-Based Batteries

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Jinhao, Meng; Stroe, Daniel-Ioan

    2018-01-01

    to describe the battery dynamics. The SOC estimation method proposed in this paper is based on an Extended Kalman Filter (EKF) and nonlinear battery model which was parameterized using extended laboratory tests performed on several 13 Ah lithium titanate oxide (LTO)-based lithium-ion batteries. The developed...

  7. Patch test study of 90 patients with tattoo reactions: negative outcome of allergy patch test to baseline batteries and culprit inks suggests allergen(s) are generated in the skin through haptenization.

    Science.gov (United States)

    Serup, Jørgen; Hutton Carlsen, Katrina

    2014-11-01

    Tattoo reactions, especially in red tattoos, are often suggested as allergic in nature, however, systematic evaluation by patch testing has not performed in the past. To report the results of patch testing in 90 patients with non-infectious chronic tattoo reactions. From 2009 to 2013 at the 'Tattoo Clinic', Department of Dermatology, Bispebjerg University Hospital, 90 patients were patch tested with batteries of baseline allergens, disperse dyes/textile allergens, and a selection of tattoo ink stock products, which, according to case observations, were problematic, supplemented with individual culprit inks when accessible. Patients with reactions to the tattoo colour red, the most predominant colour associated with skin reactions, showed negative patch test results with common allergens. Outcomes were also negative in patients who had experienced concomitant reactions in another hitherto tolerated tattoo of the same colour as the problematic tattoo. The allergen or allergens responsible for tattoo reactions are not present directly in tattoo ink stock products. This is despite the fact that clinical histories suggest that the vast majority of clinical reactions, especially reactions to red and red nuances, are likely to be allergic events caused by the injected inks. We suggest that the responsible allergen results from a complicated and slow process of haptenization, which may even include photochemical cleavage of red azo pigment. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Assessment and Functional Impact of Allocentric Neglect: A Reminder from a Case Study

    Science.gov (United States)

    Shah, Priyanka P.; Spaldo, Nicole; Barrett, A.M.; Chen, Peii

    2013-01-01

    SR suffered a right hemispheric stroke more than three years ago, and now lives with left-sided hemiparesis and chronic spatial neglect due to damaged white matter pathways connecting the frontal, temporal and parietal regions. We report here that SR suffers from both viewer-centered (i.e., egocentric) and object-centered (i.e., allocentric) spatial neglect. Notably, unlike most neuropsychological and functional assessments that focus on egocentric deficits, a specialized neuropsychological figurative discrimination test (the Apples test) revealed SR’s allocentric neglect. Further, using assessments sensitive to detect functional deficits related to allocentric neglect, we observed SR’s difficulty in reading and using clocks, reflecting his object-centered errors in these everyday activities. SR’s case suggests that allocentric-specific assessments, both neuropsychological and functional, are valuable in standard neglect examinations, particularly to predict daily function after stroke. We recommend that neglect-related functional disability be distinguished further with respect to allocentric spatial deficits, and functional assessments for allocentric neglect should be validated in future large sample studies. Identifying allocentric neglect early, and learning about its influence on daily function, may enhance care quality and facilitate effective rehabilitation planning for stroke recovery. PMID:23560431

  9. Performance Analysis of Power Bank Fitted with Recycled Laptop Batteries

    OpenAIRE

    Hartono, H; Sunarno, W; Sarwanto, S

    2017-01-01

    The result of observation at Science Laboratory of State Vocational High School 3 of Surakarta shows that the power capacity of power bank fitted with recycled laptop batteries was not tested. Power bank test was conducted by preparing used laptop batteries type 18650 from its packaging for a total of five cells, selecting batteries based on their physical appearance, cleaning the pole connections, testing the voltage, testing temperature when power charging from electric outlet to power bank...

  10. A terracotta bio-battery.

    Science.gov (United States)

    Ajayi, Folusho F; Weigele, Peter R

    2012-07-01

    Terracotta pots were converted into simple, single chamber, air-cathode bio-batteries. This bio-battery design used a graphite-felt anode and a conductive graphite coating without added catalyst on the exterior as a cathode. Bacteria enriched from river sediment served as the anode catalyst. These batteries gave an average OCV of 0.56 V ± 0.02, a Coulombic efficiency of 21 ± 5%, and a peak power of 1.06 mW ± 0.01(33.13 mW/m(2)). Stable current was also produced when the batteries were operated with hay extract in salt solution. The bacterial community on the anode of the batteries was tested for air tolerance and desiccation resistance over a period ranging from 2 days to 2 weeks. The results showed that the anode community could survive complete drying of the electrolyte for several days. These data support the further development of this technology as a potential power source for LED-based lighting in off-grid, rural communities. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Current pipelines for neglected diseases.

    Science.gov (United States)

    di Procolo, Paolo; Jommi, Claudio

    2014-09-01

    This paper scrutinises pipelines for Neglected Diseases (NDs), through freely accessible and at-least-weekly updated trials databases. It updates to 2012 data provided by recent publications, and integrates these analyses with information on location of trials coordinators and patients recruitment status. Additionally, it provides (i) disease-specific information to better understand the rational of investments in NDs, (ii) yearly data, to understand the investment trends. The search identified 650 clinical studies. Leishmaniasis, Arbovirus infection, and Dengue are the top three diseases by number of clinical studies. Disease diffusion risk seems to be the most important driver of the clinical trials target choice, whereas the role played by disease prevalence and unmet need is controversial. Number of trials is stable between 2005 and 2010, with an increase in the last two years. Patient recruitment was completed for most studies (57.6%), and Phases II and III account for 35% and 28% of trials, respectively. The primary purpose of clinical investigations is prevention (49.3%), especially for infectious diseases with mosquitoes and sand flies as the vector, and treatment (43.2%), which is the primary target for parasitic diseases Research centres and public organisations are the most important clinical studies sponsors (58.9%), followed by the pharmaceutical industry (24.1%), foundations and non-governmental organisations (9.3%). Many coordinator centres are located in less affluent countries (43.7%), whereas OECD countries and BRICS account for 34.7% and 17.5% of trials, respectively. Information was partially missing for some parameters. Notwithstanding, and despite its descriptive nature, this research has enhanced the evidence of the literature on pipelines for NDs. Future contributions may further investigate whether trials metrics are consistent with the characteristics of the interested countries and the explicative variables of trials location, target

  12. Teen birth rates in sexually abused and neglected females.

    Science.gov (United States)

    Noll, Jennie G; Shenk, Chad E

    2013-04-01

    Prospectively track teen childbirths in maltreated and nonmaltreated females and test the hypothesis that child maltreatment is an independent predictor of subsequent teen childbirth over and above demographic characteristics and other risk factors. Nulliparous adolescent females (N = 435) aged 14 to 17 years were assessed annually through age 19 years. Maltreated females were referred by Child Protective Services agencies for having experienced substantiated sexual abuse, physical abuse, or neglect within the preceding 12 months. Comparison females were matched on race, family income, age and family constellation. Teen childbirth was assessed via self-report during annual interviews. Births were confirmed using hospital delivery records. Seventy participants gave birth during the study, 54 in the maltreated group and 16 in the comparison group. Maltreated females were twice as likely to experience teen childbirth after controlling for demographic confounds and known risk factors (odds ratio = 2.17, P = 0.01). Birth rates were highest for sexually abused and neglected females. Sexual abuse and neglect were both independent predictors of teen childbirth after controlling for demographic confounds, other risk factors and alternative forms of maltreatment occurring earlier in development. Results provide evidence that sexual abuse and neglect are unique predictors of subsequent teen childbirth. Partnerships between protective service providers and teen childbirth prevention strategists hold the best promise for further reducing the US teen birth rate. Additional research illuminating the pathways to teen childbirth for differing forms of maltreatment is needed so that tailored interventions can be realized.

  13. Battery Aging and the Kinetic Battery Model

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.

    2016-01-01

    Batteries are omnipresent, and with the uprise of the electrical vehicles will their use will grow even more. However, the batteries can deliver their required power for a limited time span. They slowly degrade with every charge-discharge cycle. This degradation needs to be taken into account when

  14. Battery systems engineering

    CERN Document Server

    Rahn, Christopher D

    2012-01-01

    A complete all-in-one reference on the important interdisciplinary topic of Battery Systems Engineering Focusing on the interdisciplinary area of battery systems engineering, this book provides the background, models, solution techniques, and systems theory that are necessary for the development of advanced battery management systems. It covers the topic from the perspective of basic electrochemistry as well as systems engineering topics and provides a basis for battery modeling for system engineering of electric and hybrid electric vehicle platforms. This original

  15. Rechargeable batteries applications handbook

    CERN Document Server

    1998-01-01

    Represents the first widely available compendium of the information needed by those design professionals responsible for using rechargeable batteries. This handbook introduces the most common forms of rechargeable batteries, including their history, the basic chemistry that governs their operation, and common design approaches. The introduction also exposes reader to common battery design terms and concepts.Two sections of the handbook provide performance information on two principal types of rechargeable batteries commonly found in consumer and industrial products: sealed nickel-cad

  16. Micro Calorimeter for Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Santhanagopalan, Shriram [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-01

    As battery technology forges ahead and consumer demand for safer, more affordable, high-performance batteries grows, the National Renewable Energy Laboratory (NREL) has added a patented Micro Calorimeter to its existing family of R&D 100 Award-winning Isothermal Battery Calorimeters (IBCs). The Micro Calorimeter examines the thermal signature of battery chemistries early on in the design cycle using popular coin cell and small pouch cell designs, which are simple to fabricate and study.

  17. Medical neglect at a tertiary paediatric hospital.

    Science.gov (United States)

    Parmeter, Julia; Tzioumi, Dimitra; Woolfenden, Susan

    2018-03-01

    Medical neglect is under-researched and the extent of the problem in Australia is unknown. We conducted a review of the referrals for medical neglect to the Child Protection Unit (CPU) at a tertiary children's hospital in Sydney over a 5 years period, from 2011 to 2016, to determine what medical conditions are being referred, the reason for the medical neglect concern and whether cases are managed in line with American Academy of Pediatrics (AAP) guideline on medical neglect. 61 cases of medical neglect were identified, constituting 4.1% of all referrals to the Child Protection Unit for physical abuse and neglect. There was a wide variety of medical conditions. Most were chronic medical conditions (87%). The top two medical conditions were chronic and complex multi-system disorders (37.7%) and endocrine disorders (18%). The majority of medical neglect were related to concerns that the caregivers were unwilling to follow medical advice (45.9%) or unable to provide necessary medical care (26.2%). In line with the AAP guideline on medical neglect, all cases were managed by addressing communication difficulties (100%) and resource issues were addressed in 80% of cases. A report to statutory child protection agencies was made in 50% of cases. Directly observed therapy and medical contracts were used in 30% and 26% of cases. We conclude that children with chronic medical conditions may be at risk of medical neglect. Communication difficulties were a factor in all cases. Statutory agency intervention is often required. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Electric Vehicle Battery Challenge

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    A serious drawback to electric vehicles [batteries only] is the idle time needed to recharge their batteries. In this challenge, students can develop ideas and concepts for battery change-out at automotive service stations. Such a capability would extend the range of electric vehicles.

  19. Battery Control Boards for Li-Ion Batteries on Mars Exploration Rovers

    Science.gov (United States)

    Ewell, R.; Ratnakumar, B. V.; Smart, M.; Chin, K. B.; Whitcanack, L.; Narayanan, S. R.; Surampudi, S.

    2006-01-01

    Rechargeable Lithium-ion batteries have been operating successfully on both Spirit and Opportunity rovers for the last two years, which includes six months of Assembly Launch and Test Operations (ATLO), seven months of cruise and about eleven months of surface operations. The Battery Control Boards designed and fabricated in-house would protect cells against overcharge and over-discharge and provide cell balance. Their performance has thus far been quite satisfactory. The ground data o the mission simulation battery project little capacity loss of less than 3% during cruise and 180 sols. Batteries are poised to extend the mission beyond six months, if not a couple of years.

  20. Battery selection for Space Shuttle experiments

    Science.gov (United States)

    Francisco, David R.

    1993-04-01

    This paper will delineate the criteria required for the selection of batteries as a power source for space experiments. Four basic types of batteries will be explored, lead acid, silver zinc, alkaline manganese, and nickel cadmium. A detailed description of the lead acid and silver zinc cells and a brief exploration of the alkaline manganese and nickel cadmium will be given. The factors involved in battery selection such as packaging, energy density, discharge voltage regulation, and cost will be thoroughly examined. The pros and cons of each battery type will be explored. Actual laboratory test data acquired for the lead acid and silver zinc cell will be discussed. This data will include discharging under various temperature conditions, after three months of storage, and with different types of loads. The lifetime and number of charge/discharge cycles will also be discussed. A description of the required maintenance for each type of battery will be investigated.

  1. The Mobility Assessment Course for the Diagnosis of Spatial Neglect: Taking a Step Forward?

    Directory of Open Access Journals (Sweden)

    Megan Grech

    2017-10-01

    Full Text Available Spatial neglect after stroke can be a challenging syndrome to diagnose under standard neuropsychological assessment. There is now sufficient evidence that those affected might demonstrate neglect behavior in everyday settings despite showing no signs of neglect during common neglect tasks. This discrepancy is attributed to the simplified and unrealistic nature of common pen and paper based tasks that do not match the demanding, novel, and complex environment of everyday life. As such, increasing task demands under more ecologically valid scenarios has become an important method of increasing test sensitivity. The main aim of the current study was to evaluate the diagnostic utility of the Mobility Assessment Course (MAC, an ecological task, for the assessment of neglect. If neglect becomes more apparent under more challenging task demands the MAC could prove to be more diagnostically accurate at detecting neglect than conventional methods, particularly as the time from initial brain damage increases. Data collected by Guide Dogs of SA/NT were retrospectively analyzed. The Receiver Operating Characteristic (ROC curve, a measure of sensitivity and specificity, was used to investigate the diagnostic utility of the MAC and a series of paper and pencil tests in 67 right hemisphere stroke survivors. While the MAC proved to be a more sensitive neglect test (74.2% when compared to the Star Cancellation (43.3% and Line Bisection (35.7% tests, this was at the expense of relatively low specificity. As a result, the ROC curve analysis showed no statistically discernable differences between tasks (p > 0.12, or between subacute and chronic groups for individual tasks (p > 0.45. It is concluded that, while the MAC is an ecologically valid alternative for assessing neglect, regarding its diagnostic accuracy, there is currently not enough evidence to suggest that it is a big step forward in comparison to the accuracy of conventional tests.

  2. Results of electric-vehicle propulsion system performance on three lead-acid battery systems

    Science.gov (United States)

    Ewashinka, J. G.

    1984-01-01

    Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

  3. Childhood neglect and adulthood involvement in HIV-related risk behaviors.

    Science.gov (United States)

    Klein, Hugh; Elifson, Kirk W; Sterk, Claire E

    2007-01-01

    Much research has been done to examine the long-term effects of being victimized by sexual, physical, and/or emotional abuse in childhood, but much less research has focused on the impact of childhood neglect experiences. This study examines the role that childhood neglect has on adult women's involvement in HIV-related risky behaviors. The data come from a study of 250 "at risk" women living in the Atlanta, GA metropolitan area, most of whom were African American. Data were collected in face-to-face interviews between 1997 and 2000. Multiple regression was used to explore the relationship between childhood neglect experiences, self-esteem, attitudes toward condom use, and involvement in HIV-related risky behaviors. Overall, the model tested received strong support by the study data. Childhood neglect led to reduced self-esteem. Neglect was associated with worsened attitudes toward condom use and women who experienced childhood neglect also reported more involvement in HIV risk behaviors. HIV intervention programs ought to target women who have experienced childhood neglect, as neglect experiences have adverse impacts upon their self-esteem, condom-related attitudes, and HIV risk behavior practices in adulthood.

  4. Evaluation of Ponseti method in neglected clubfoot

    Directory of Open Access Journals (Sweden)

    Abhinav Sinha

    2016-01-01

    Conclusions: Painless, supple, plantigrade, and cosmetically acceptable feet were achieved in neglected clubfeet without any extensive surgery. A fair trial of conservative Ponseti method should be tried before resorting to extensive soft tissue procedure.

  5. Therapeutics for Rare and Neglected Diseases

    Data.gov (United States)

    Federal Laboratory Consortium — There are more than 6,500 identified rare and neglected diseases, yet only about 250 treatments are available for these conditions. The limited numbers of patients...

  6. Multiple Aptitude Battery-II Normative Intelligence Test Data That Distinguish U.S. Air Force AC-130 Gunship Sensor Operators

    Science.gov (United States)

    2010-06-01

    lstead, 1961; Hom & Cattell, 1966; Hebb, 1972, Piaget , 1950) to highly complex information processing approaches (Sternberg. 1985). Despite the notion of...Aptitude Battery- Second Edition {MAS-II) . Sigma Assessment Systems, Inc. Port Huron, MI. Piaget , J. (1950). The psychology of intelligence. New York

  7. Ipsilesional Neglect: Behavioral and Anatomical Correlates

    Science.gov (United States)

    Sacchetti, Daniela L.; Goedert, Kelly M.; Foundas, Anne L.; Barrett, A.M.

    2014-01-01

    Objective The sparse existing research on ipsilesional neglect supports an association of this disorder with damage to the right frontal and subcortical brain networks. It is believed that dysfunction in these networks may result in primarily “aiming”, motor-intentional spatial errors. The purpose of this study was to confirm whether frontal-subcortical circuits are indeed commonly affected in ipsilesional neglect and to determine the relative presence of “aiming”, motor-intentional versus “where”, perceptual-attentional spatial errors in these individuals. Methods We identified 12 participants with ipsilesional neglect based on a computerized line bisection task and used the line bisection data to quantify participants' perceptual-attentional and motor-intentional errors. We were able to discriminate between these two biases using the algebraic solutions for two separate equations, one for “aiming” and one for “where” biases. Lesion mapping was conducted for all participants using MRICroN® software; lesion checklist and overlap analysis were created from these images. Results A greater percentage of participants with ipsilesional neglect had frontal/subcortical damage (83%) compared to the expected percentage (27%) observed in published patient samples with contralesional neglect. We observed the greatest area of lesion overlap in frontal lobe white matter pathways. Nevertheless, participants with ipsilesional neglect made primarily “where” rather than “aiming” spatial errors. Conclusion Our data confirms previous research suggesting that ipsilesional neglect may result from lesions to the right frontal-subcortical networks. Furthermore, in our group, ipsilesional neglect was also strongly associated with primarily “where”, perceptual-attentional bias, and less so with “aiming” motor-intentional spatial bias. PMID:25180980

  8. Neglect dyslexia: a matter of "good looking".

    Science.gov (United States)

    Primativo, Silvia; Arduino, Lisa S; De Luca, Maria; Daini, Roberta; Martelli, Marialuisa

    2013-09-01

    Brain-damaged patients with right-sided unilateral spatial neglect (USN) often make left-sided errors in reading single words or pseudowords (neglect dyslexia, ND). We propose that both left neglect and low fixation accuracy account for reading errors in neglect dyslexia. Eye movements were recorded in USN patients with (ND+) and without (ND-) neglect dyslexia and in a matched control group of right brain-damaged patients without neglect (USN-). Unlike ND- and controls, ND+ patients showed left lateralized omission errors and a distorted eye movement pattern in both a reading aloud task and a non-verbal saccadic task. During reading, the total number of fixations was larger in these patients independent of visual hemispace, and most fixations were inaccurate. Similarly, in the saccadic task only ND+ patients were unable to reach the moving dot. A third experiment addressed the nature of the left lateralization in reading error distribution by simulating neglect dyslexia in ND- patients. ND- and USN- patients had to perform a speeded reading-at-threshold task that did not allow for eye movements. When stimulus exploration was prevented, ND- patients, but not controls, produced a pattern of errors similar to that of ND+ with unlimited exposure time (e.g., left-sided errors). We conclude that neglect dyslexia reading errors may arise in USN patients as a consequence of an additional and independent deficit unrelated to the orthographic material. In particular, the presence of an altered oculo-motor pattern, preventing the automatic execution of the fine saccadic eye movements involved in reading, uncovers, in USN patients, the attentional bias also in reading single centrally presented words. © 2013 Elsevier Ltd. All rights reserved.

  9. Cognitive processes associated with child neglect.

    Science.gov (United States)

    Hildyard, Kathryn; Wolfe, David

    2007-08-01

    To compare neglectful and non-neglectful mothers on information processing tasks related to child emotions, behaviors, the caregiving relationship, and recall of child-related information. A natural group design was used. Neglectful mothers (N=34) were chosen from active, chronic caseloads; non-neglectful comparison mothers (N=33) were obtained from community agencies serving families. Participants were administered the IFEEL Picture task to assess maternal perceptions of infant emotions, eight vignettes of young children's behavior to assess attributions for child behavior across different scenarios, and a passage recall task to assess information processing problems. A measure of depression was used as a covariate to control for this variable. Neglectful mothers were significantly less likely to recognize infants' feelings of interest, more likely to see sadness and shame, more inaccurate at labeling infants' emotions, and had a more limited emotion vocabulary. They also made more internal and stable attributions for children's behaviors in situations where it was not clear whether a child was at risk of harm, and had poor recall of information. Depressive symptoms had little effect on these findings with the exception of information recall. Neglectful mothers show significant problems in information processing concerning their child's emotions and behaviors, which may affect their childrearing behavior. Cognitive-behavioral interventions to improve parents' abilities to recognize their child's emotions and to address maladaptive attributions may be of value.

  10. Empathy and child neglect: a theoretical model.

    Science.gov (United States)

    De Paul, Joaquín; Guibert, María

    2008-11-01

    To present an explanatory theory-based model of child neglect. This model does not address neglectful behaviors of parents with mental retardation, alcohol or drug abuse, or severe mental health problems. In this model parental behavior aimed to satisfy a child's need is considered a helping behavior and, as a consequence, child neglect is considered as a specific type of non-helping behavior. The central hypothesis of the theoretical model presented here suggests that neglectful parents cannot develop the helping response set to care for their children because the observation of a child's signal of need does not lead to the experience of emotions that motivate helping or because the parents experience these emotions, but specific cognitions modify the motivation to help. The present theoretical model suggests that different typologies of neglectful parents could be developed based on different reasons that parents might not to experience emotions that motivate helping behaviors. The model can be helpful to promote new empirical studies about the etiology of different groups of neglectful families.

  11. Electrochemical accumulators batteries; Accumulateurs electrochimiques batteries

    Energy Technology Data Exchange (ETDEWEB)

    Ansart, F.; Castillo, S.; Laberty- Robert, C.; Pellizon-Birelli, M. [Universite Paul Sabatier, Lab. de Chimie des Materiaux Inorganiques et Energetiques, CIRIMAT, UMR CNRS 5085, 31 - Toulouse (France)] [and others

    2000-07-01

    It is necessary to storage the electric power in batteries to join the production and the utilization. In this domain progresses are done every days in the technics and also in the available materials. These technical days present the state of the art in this domain. Many papers were presented during these two days giving the research programs and recent results on the following subjects: the lithium batteries, the electrolytes performances and behaviour, lead accumulators, economic analysis of the electrochemical storage market, the batteries applied to the transportation sector and the telephones. (A.L.B.)

  12. NASA Aerospace Flight Battery Program: Generic Safety, Handling and Qualification Guidelines for Lithium-Ion (Li-Ion) Batteries; Availability of Source Materials for Lithium-Ion (Li-Ion) Batteries; Maintaining Technical Communications Related to Aerospace Batteries (NASA Aerospace Battery Workshop). Volume 1, Part 1

    Science.gov (United States)

    Manzo, Michelle A.; Brewer, Jeffrey C.; Bugga, Ratnakumar V.; Darcy, Eric C.; Jeevarajan, Judith A.; McKissock, Barbara I.; Schmitz, Paul C.

    2010-01-01

    This NASA Aerospace Flight Battery Systems Working Group was chartered within the NASA Engineering and Safety Center (NESC). The Battery Working Group was tasked to complete tasks and to propose proactive work to address battery related, agency-wide issues on an annual basis. In its first year of operation, this proactive program addressed various aspects of the validation and verification of aerospace battery systems for NASA missions. Studies were performed, issues were discussed and in many cases, test programs were executed to generate recommendations and guidelines to reduce risk associated with various aspects of implementing battery technology in the aerospace industry. This document contains Part 1 - Volume I: Generic Safety, Handling and Qualification Guidelines for Lithium-Ion (Li-Ion) Batteries, Availability of Source Materials for Lithium-Ion (Li-Ion) Batteries, and Maintaining Technical Communications Related to Aerospace Batteries (NASA Aerospace Battery Workshop).

  13. Prodrugs for the Treatment of Neglected Diseases

    Directory of Open Access Journals (Sweden)

    Lorena Blau

    2007-03-01

    Full Text Available Recently, World Health Organization (WHO and Medicins San Frontieres (MSF proposed a classification of diseases as global, neglected and extremely neglected. Global diseases, such as cancer, cardiovascular and mental (CNS diseases represent the targets of the majority of the R&D efforts of pharmaceutical companies. Neglected diseases affect millions of people in the world yet existing drug therapy is limited and often inappropriate. Furthermore, extremely neglected diseases affect people living under miserable conditions who barely have access to the bare necessities for survival. Most of these diseases are excluded from the goals of the R&D programs in the pharmaceutical industry and therefore fall outside the pharmaceutical market. About 14 million people, mainly in developing countries, die each year from infectious diseases. From 1975 to 1999, 1393 new drugs were approved yet only 1% were for the treatment of neglected diseases [3]. These numbers have not changed until now, so in those countries there is an urgent need for the design and synthesis of new drugs and in this area the prodrug approach is a very interesting field. It provides, among other effects, activity improvements and toxicity decreases for current and new drugs, improving market availability. It is worth noting that it is essential in drug design to save time and money, and prodrug approaches can be considered of high interest in this respect. The present review covers 20 years of research on the design of prodrugs for the treatment of neglected and extremely neglected diseases such as Chagas’ disease (American trypanosomiasis, sleeping sickness (African trypanosomiasis, malaria, sickle cell disease, tuberculosis, leishmaniasis and schistosomiasis.

  14. Novel insights in the rehabilitation of neglect.

    Directory of Open Access Journals (Sweden)

    Luciano eFasotti

    2013-11-01

    Full Text Available Visuospatial neglect due to right hemisphere damage, usually a stroke, is a major cause of disability, impairing the ability to perform a whole range of everyday life activities. Conventional and long-established methods for the rehabilitation of neglect like visual scanning training, optokinetic stimulation or limb activation training have produced positive results, with varying degrees of generalisation to (untrained tasks lasting from several minutes up to various months after training. Nevertheless, some promising novel approaches to the remediation of left visuo-spatial neglect have emerged in the last decade. These new therapy methods can be broadly classified into 4 categories. First, non-invasive brain stimulation techniques by means of transcranial magnetic stimulation (TMS or transcranial direct current stimulation (tDCS, after a period of mainly diagnostic utilization, are increasingly applied as neurorehabilitative tools. Second, two classes of drugs, dopaminergic and noradrenergic, have been investigated for their potential effectiveness in rehabilitating neglect. Third, prism adaptation treatment has been shown to improve several neglect symptoms consistently, sometimes during longer periods of time. Finally, virtual reality technologies hold new opportunities for the development of effective training techniques for neglect. They provide realistic, rich and highly controllable training environments. In this paper the degree of effectiveness and the evidence gathered to support the therapeutic claims of these new approaches is reviewed and discussed. The conclusion is that for all these approaches there still is insufficient unbiased evidence to support their effectiveness. Further neglect rehabilitation research should focus on the maintenance of therapy results over time, on a more functional evaluation of treatment effects, on the design and execution of true replication studies and on the exploration of optimal combinations of

  15. Neglect and Extinction Depend Greatly on Task Demands: A Review

    Science.gov (United States)

    Bonato, Mario

    2012-01-01

    This review illustrates how, after unilateral brain damage, the presence and severity of spatial awareness deficits for the contralesional hemispace depend greatly on the quantity of attentional resources available for performance. After a brief description of neglect and extinction, different frameworks accounting for spatial and non-spatial attentional processes will be outlined. The central part of the review describes how the performance of brain-damaged patients is negatively affected by increased task demands, which can result in the emergence of severe awareness deficits for contralesional space even in patients who perform normally on paper-and-pencil tests. Throughout the review neglect is described as a spatial syndrome that can be exacerbated in the presence and severity by both spatial and non-spatial tasks. The take-home message is that the presence and degree of contralesional neglect and extinction can be dramatically overlooked based on standard clinical (paper-and-pencil) testing, where patients can easily compensate for their deficits. Only tasks where compensation is made impossible represent an appropriate approach to detect these disabling contralesional deficits of awareness when they become subtle in post-acute stroke phases. PMID:22822394

  16. Lifetime Improvement by Battery Scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Schmitt, Jens B.; Haverkort, Boudewijn R.H.M.

    The use of mobile devices is often limited by the lifetime of their batteries. For devices that have multiple batteries or that have the option to connect an extra battery, battery scheduling, thereby exploiting the recovery properties of the batteries, can help to extend the system lifetime. Due to

  17. Lifetime improvement by battery scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.

    The use of mobile devices is often limited by the lifetime of its battery. For devices that have multiple batteries or that have the option to connect an extra battery, battery scheduling, thereby exploiting the recovery properties of the batteries, can help to extend the system lifetime. Due to the

  18. Development of Lithium Inorganic Electrolyte Batteries for Navy Applications

    Science.gov (United States)

    1975-10-01

    cooker to contain the explosion. Five to seven minutes after the circuit was shorted the first battery detonated and smoke appeared at the vent...blowing the lid off the pressure cooker and scattering the battery remains. 54 54 Test 8 Test 8 and 9 were conducted under similar conditions to...twenty power-source candidates (various batteries, thermoelectric generators, solar cells, engine generators, etc.), based on a matrix of hypotehtical

  19. Spatial attention systems in spatial neglect.

    Science.gov (United States)

    Karnath, Hans-Otto

    2015-08-01

    It has been established that processes relating to 'spatial attention' are implemented at cortical level by goal-directed (top-down) and stimulus-driven (bottom-up) networks. Spatial neglect in brain-damaged individuals has been interpreted as a distinguished exemplar for a disturbance of these processes. The present paper elaborates this assumption. Functioning of the two attentional networks seem to dissociate in spatial neglect; behavioral studies of patients' orienting and exploration behavior point to a disturbed stimulus-driven but preserved goal-directed attention system. When a target suddenly appears somewhere in space, neglect patients demonstrate disturbed detection and orienting if it is located in contralesional direction. In contrast, if neglect patients explore a scene with voluntarily, top-down controlled shifts of spatial attention, they perform movements that are oriented into all spatial directions without any direction-specific disturbances. The paper thus argues that not the top-down control of spatial attention itself, rather a body-related matrix on top of which this process is executed, seems affected. In that sense, the traditional role of spatial neglect as a stroke model for 'spatial attention' requires adjustment. Beyond its insights into the human stimulus-driven attentional system, the disorder most notably provides vistas in how our brain encodes topographical information and organizes spatially oriented action - including the top-down control of spatial attention - in relation to body position. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. A desalination battery.

    Science.gov (United States)

    Pasta, Mauro; Wessells, Colin D; Cui, Yi; La Mantia, Fabio

    2012-02-08

    Water desalination is an important approach to provide fresh water around the world, although its high energy consumption, and thus high cost, call for new, efficient technology. Here, we demonstrate the novel concept of a "desalination battery", which operates by performing cycles in reverse on our previously reported mixing entropy battery. Rather than generating electricity from salinity differences, as in mixing entropy batteries, desalination batteries use an electrical energy input to extract sodium and chloride ions from seawater and to generate fresh water. The desalination battery is comprised by a Na(2-x)Mn(5)O(10) nanorod positive electrode and Ag/AgCl negative electrode. Here, we demonstrate an energy consumption of 0.29 Wh l(-1) for the removal of 25% salt using this novel desalination battery, which is promising when compared to reverse osmosis (~ 0.2 Wh l(-1)), the most efficient technique presently available. © 2012 American Chemical Society

  1. A Desalination Battery

    KAUST Repository

    Pasta, Mauro

    2012-02-08

    Water desalination is an important approach to provide fresh water around the world, although its high energy consumption, and thus high cost, call for new, efficient technology. Here, we demonstrate the novel concept of a "desalination battery", which operates by performing cycles in reverse on our previously reported mixing entropy battery. Rather than generating electricity from salinity differences, as in mixing entropy batteries, desalination batteries use an electrical energy input to extract sodium and chloride ions from seawater and to generate fresh water. The desalination battery is comprised by a Na 2-xMn 5O 10 nanorod positive electrode and Ag/AgCl negative electrode. Here, we demonstrate an energy consumption of 0.29 Wh l -1 for the removal of 25% salt using this novel desalination battery, which is promising when compared to reverse osmosis (∼ 0.2 Wh l -1), the most efficient technique presently available. © 2012 American Chemical Society.

  2. Galvanic vestibular stimulation improves arm position sense in spatial neglect: a sham-stimulation-controlled study.

    Science.gov (United States)

    Schmidt, Lena; Keller, Ingo; Utz, Kathrin S; Artinger, Frank; Stumpf, Oliver; Kerkhoff, Georg

    2013-01-01

    Disturbed arm position sense (APS) is a frequent and debilitating condition in patients with hemiparesis after stroke. Patients with neglect, in particular, show a significantly impaired contralesional APS. Currently, there is no treatment available for this disorder. Galvanic vestibular stimulation (GVS) may ameliorate neglect and extinction by activating the thalamocortical network. The present study aimed to investigate the immediate effects and aftereffects (AEs; 20 minutes) of subsensory, bipolar GVS (M = 0.6 mA current intensity) on APS in stroke patients with versus without spatial neglect and matched healthy controls. A novel optoelectronic arm position device was developed, enabling the precise measurement of the horizontal APS of both arms. In all, 10 healthy controls, 7 patients with left-sided hemiparesis and left-spatial neglect, and 15 patients with left hemiparesis but without neglect were tested. Horizontal APS was measured separately for both forearms under 4 experimental conditions (baseline without GVS, left-cathodal/right-anodal GVS, right-cathodal/left-anodal GVS, sham GVS). The immediate effects during GVS and the AEs 20 minutes after termination of GVS were examined. Patients with neglect showed an impaired contralateral APS in contrast to patients without neglect and healthy controls. Left-cathodal/right-anodal GVS improved left APS significantly, which further improved into the normal range 20 minutes poststimulation. GVS had no effect in patients without neglect but right-cathodal/left-anodal GVS worsened left APS in healthy participants significantly. GVS can significantly improve the impaired APS in neglect. Multisession GVS can be tested to induce enduring therapeutic effects.

  3. Clock Drawing in Spatial Neglect: A Comprehensive Analysis of Clock Perimeter, Placement, and Accuracy

    Science.gov (United States)

    Chen, Peii; Goedert, Kelly M.

    2012-01-01

    Clock drawings produced by right-brain-damaged (RBD) individuals with spatial neglect often contain an abundance of empty space on the left while numbers and hands are placed on the right. However, the clock perimeter is rarely compromised in neglect patients’ drawings. By analyzing clock drawings produced by 71 RBD and 40 healthy adults, this study investigated whether the geometric characteristics of the clock perimeter reveal novel insights to understanding spatial neglect. Neglect participants drew smaller clocks than either healthy or non-neglect RBD participants. While healthy participants’ clock perimeter was close to circular, RBD participants drew radially extended ellipses. The mechanisms for these phenomena were investigated by examining the relation between clock-drawing characteristics and performance on six subtests of the Behavioral Inattention Test (BIT). The findings indicated that the clock shape was independent of any BIT subtest or the drawing placement on the test sheet and that the clock size was significantly predicted by one BIT subtest: the poorer the figure and shape copying, the smaller the clock perimeter. Further analyses revealed that in all participants, clocks decreased in size as they were placed farther from the center of the paper. However, even when neglect participants placed their clocks towards the center of the page, they were smaller than those produced by healthy or non-neglect RBD participants. These results suggest a neglect-specific reduction in the subjectively available workspace for graphic production from memory, consistent with the hypothesis that neglect patients are impaired in the ability to enlarge the attentional aperture. PMID:22390278

  4. Third International Conference on Batteries for Utility Energy Storage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-03-18

    This is a collection of essays presented at the above-named conference held at Kobe, Japan, from March 18 through 22, 1991. At the utility energy storage session, a power research program plan, operational and economic benefits of BESP (battery energy storage plant), the Moonlight Project, etc., were presented, respectively, by EPRI (Electric Power Research Institute) of the U.S., BEWAG Corporation of Germany, and NEDO (New Energy and Industrial Technology Development Organization) of Japan, etc. At the improved lead-acid batteries session, the characteristics of improved lead-acid batteries, load levelling and life cycle, problems in BESP, comparisons and tests, etc., were presented by Japan, Italy, the U.S., etc. At the advanced batteries session, presentations were made about the sodium-sulfur battery, zinc-bromine battery, redox battery, etc. Furthermore, there were sessions on consumer energy systems, control and power conditioning technology, and commercialization and economic studies. A total 53 presentations were made. (NEDO)

  5. Error Types and Error Positions in Neglect Dyslexia: Comparative Analyses in Neglect Patients and Healthy Controls

    Science.gov (United States)

    Weinzierl, Christiane; Kerkhoff, Georg; van Eimeren, Lucia; Keller, Ingo; Stenneken, Prisca

    2012-01-01

    Unilateral spatial neglect frequently involves a lateralised reading disorder, neglect dyslexia (ND). Reading of single words in ND is characterised by left-sided omissions and substitutions of letters. However, it is unclear whether the distribution of error types and positions within a word shows a unique pattern of ND when directly compared to…

  6. Neglect Dyslexia: Frequency, Association with Other Hemispatial Neglects, and Lesion Localization

    Science.gov (United States)

    Lee, Byung Hwa; Suh, Mee Kyung; Kim, Eun-Joo; Seo, Sang Won; Choi, Kyung Mook; Kim, Gyeong-Moon; Chung, Chin-Sang; Heilman, Kenneth M.; Na, Duk L.

    2009-01-01

    Patients with right hemisphere injury often omit or misread words on the left side of a page or the beginning letters of single words (neglect dyslexia). Our study involving a large sample of acute right hemisphere stroke investigated (1) the frequency of neglect dyslexia (ND), (2) the association between ND and other types of contralesional…

  7. Lithium battery management system

    Science.gov (United States)

    Dougherty, Thomas J [Waukesha, WI

    2012-05-08

    Provided is a system for managing a lithium battery system having a plurality of cells. The battery system comprises a variable-resistance element electrically connected to a cell and located proximate a portion of the cell; and a device for determining, utilizing the variable-resistance element, whether the temperature of the cell has exceeded a predetermined threshold. A method of managing the temperature of a lithium battery system is also included.

  8. A preliminary investigation into the psychometric properties of the Dublin Extrapersonal Neglect Assessment (DENA): A novel screening tool for extrapersonal neglect.

    Science.gov (United States)

    Cunningham, Libby J; O'Rourke, Killian; Finlay, Ciara; Gallagher, MaryBeth

    2017-04-01

    Extrapersonal neglect is one clinical manifestation that can occur following stroke. Existing neglect assessment procedures have been criticised for lengthy administration and do not assess how extrapersonal space is affected. This study investigated the psychometric properties of a new, time-efficient screening tool for extrapersonal neglect. Full ethical approval was granted and consent obtained from 50 participants with first-time stroke. Participants were screened for extrapersonal neglect on two consecutive days by two raters using the Dublin Extrapersonal Neglect Assessment (DENA) to test inter-rater reliability. Construct validity of the DENA was investigated by comparing the DENA to the Catherine Bergego Scale (CBS). Additional analyses were calculated between the DENA and the extrapersonal items of the CBS (CBS-E). The kappa statistic, intraclass correlation coefficients (ICCs) and Bland Altman analyses were calculated to determine excellent inter-rater reliability (ICC 0.971, κ = .876) and significant correlation between the DENA and the CBS and CBS-E (ICC 0.870, 0.934, κ = .793, .833, respectively). Bland Altman analyses demonstrated acceptable levels of agreement between the DENA raters, and the DENA and CBS, with no systematic differences evident. The DENA provides clinicians with a quick and psychometrically sound screening tool for extrapersonal neglect to ensure this impairment is addressed in stroke rehabilitation.

  9. SOLID STATE BATTERIES WITH CONDUCTING POLYMERS

    OpenAIRE

    Bénière , F.; Boils , D.; Cánepa , H.; Franco , J.; Le Corre , A.; Louboutin , J.

    1983-01-01

    The conducting polymers like (CH)x are very interesting materials for electrodes in electrochemical cells. We have combined such electrodes with solid electrolytes to build "all solid-state" batteries. The first prototypes using a silver anode and a silver conducting electrolyte have been working satisfactorily since two years. The performances have been tested with many batteries to study the electrical properties as well as the thermodynamical parameters. A number of cycles of charge-discha...

  10. Battery Thermal Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Keyser, Matthew A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-08

    The operating temperature is critical in achieving the right balance between performance, cost, and life for both Li-ion batteries and ultracapacitors. The chemistries of advanced energy-storage devices - such as lithium-based batteries - are very sensitive to operating temperature. High temperatures degrade batteries faster while low temperatures decrease their power and capacity, affecting vehicle range, performance, and cost. Understanding heat generation in battery systems - from the individual cells within a module, to the inter-connects between the cells, and across the entire battery system - is imperative for designing effective thermal-management systems and battery packs. At NREL, we have developed unique capabilities to measure the thermal properties of cells and evaluate thermal performance of battery packs (air or liquid cooled). We also use our electro-thermal finite element models to analyze the thermal performance of battery systems in order to aid battery developers with improved thermal designs. NREL's tools are used to meet the weight, life, cost, and volume goals set by the U.S. Department of Energy for electric drive vehicles.

  11. Ballistic negatron battery

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, M.S.R. [Koneru Lakshmiah Univ.. Dept. of Electrical and Electronics Engineering, Green fields, Vaddeswaram (India)

    2012-07-01

    If we consider the Statistics there is drastic increase in dependence of batteries from year to year, due to necessity of power storage equipment at homes, power generating off grid and on grid Wind, PV systems, etc.. Where wind power is leading in renewable sector, there is a need to look at its development. Considering the scenario in India, most of the wind resource areas are far away from grid and the remaining areas which are near to grid are of low wind currents which is of no use connecting these equipment directly to grid. So, there is a need for a power storage utility to be integrated, such as the BNB (Ballistic Negatron Battery). In this situation a country like India need a battery which should be reliable, cheap and which can be industrialized. So this paper presents the concept of working, design, operation, adaptability of a Ballistic Negatron Battery. Unlike present batteries with low energy density, huge size, more weight, more charging time and low resistant to wear level, this Ballistic Negatron Battery comes with, 1) High energy storage capability (many multiples more than the present most advanced battery). 2) Very compact in size. 3) Almost negligible in weight compared to present batteries. 4) Charges with in very less time. 5) Never exhibits a wear level greater than zero. Seems like inconceivable but adoptable with simple physics. This paper will explains in detail the principle, model, design, construction and practical considerations considered in making this battery. (Author)

  12. Flow Battery System Design for Manufacturability.

    Energy Technology Data Exchange (ETDEWEB)

    Montoya, Tracy Louise; Meacham, Paul Gregory; Perry, David; Broyles, Robin S.; Hickey, Steven; Hernandez, Jacquelynne

    2014-10-01

    Flow battery energy storage systems can support renewable energy generation and increase energy efficiency. But, presently, the costs of flow battery energy storage systems can be a significant barrier for large-scale market penetration. For cost- effective systems to be produced, it is critical to optimize the selection of materials and components simultaneously with the adherence to requirements and manufacturing processes to allow these batteries and their manufacturers to succeed in the market by reducing costs to consumers. This report analyzes performance, safety, and testing requirements derived from applicable regulations as well as commercial and military standards that would apply to a flow battery energy storage system. System components of a zinc-bromine flow battery energy storage system, including the batteries, inverters, and control and monitoring system, are discussed relative to manufacturing. The issues addressed include costs and component availability and lead times. A service and support model including setup, maintenance and transportation is outlined, along with a description of the safety-related features of the example flow battery energy storage system to promote regulatory and environmental, safety, and health compliance in anticipation of scale manufacturing.

  13. Nickel-iron battery system safety

    Science.gov (United States)

    Saltat, R. C.

    1984-06-01

    The generated flow rates of gaseous hydrogen and gaseous oxygen from an electrical vehicle nickel-iron battery system were determined and used to evaluate the flame quenching capabilities of several candidate devices to prevent flame propagation within batteries having central watering/venting systems. The battery generated hydrogen and oxygen gases were measured for a complete charge and discharge cycle. The data correlates well with accepted theory during strong overcharge conditions indicating that the measurements are valid for other portions of the cycle. Tests confirm that the gas mixture in the cells is always flammable regardless of the battery status. The literature indicated that a conventional flame arrestor would not be effective over the broad spectrum of gassing conditions presented by a nickel-iron battery. Four different types of protective devices were evaluated. A foam-metal arrestor design was successful in quenching gaseous hydrogen and gaseous oxygen flames, however; the application of this flame arrestor to individual cell or module protection in a battery is problematic. A possible rearrangement of the watering/venting system to accept the partial protection of simple one-way valves is presented which, in combination with the successful foam-metal arrestor as main vent protection, could result in a significant improvement in battery protection.

  14. Definition, Measuring and Prevalence of Child Neglect

    DEFF Research Database (Denmark)

    Christensen, Else

    Ten per cent of Danish children under one year of age live in families with serious problems. Their parents are subjected to psychological and/or social strains to such a dergree that public authorities, typically the visiting health nurse, are concerned about the welfare of the childre. A smaller...... group, although at least four per cent of all children under one year of age, is subjected to child abuse and neglect. In her study, Else Christensen has attempted to estimate the extent of the problem among children under the age of one year. Furthermose, she has made a theoetical and practical...... clarification of the concept child abuse and neglect. Excatly which signs is the health nurse to observe in order to employ the serious term child abuse and neglect?...

  15. Neglecting posture: differences in balance impairments between peripersonal and extrapersonal neglect.

    Science.gov (United States)

    Nijboer, Tanja C W; Ten Brink, Antonia F; van der Stoep, Nathan; Visser-Meily, Johanna M A

    2014-12-03

    Neglect is a heterogeneous disorder and may be specific for only peripersonal or extrapersonal space. Behavioural consequences at the level of independency in basic activities of daily living differ between patients with peripersonal and those with extrapersonal neglect. One of the most important factors that determine independency in basic activities of daily living is balance. Here, potential differences in postural imbalance between patients with peripersonal and those with extrapersonal neglect were investigated. A total of 81 stroke patients were screened within the first 2 weeks after admission to the rehabilitation centre. Mediolateral (horizontal) and anteroposterior (vertical) displacements of the centre of pressure (CoP) were measured using a Nintendo Wii Balance Board in an eyes-open and eyes-closed condition. Patients with peripersonal neglect showed a significant displacement of mediolateral CoP from the ideal CoP, but not in the anteroposterior dimension or postural sway. Patients with extrapersonal neglect did not differ from the no-neglect patients in terms of displacement of both mediolateral and anteroposterior CoP and postural sway. There were no differences between the eyes-open and eyes-closed conditions in any of the groups. Consequences of region-specific neglect on postural imbalance appear to be very specific and cannot be accounted for by neglecting visual information only. The current findings might directly reflect a relation between body perception and body representation and (actions in) peripersonal space. When diagnosing neglect, it is relevant to distinguish the type of region-specific neglect and, when needed, to adjust the rehabilitation programme accordingly.

  16. VRLA automotive batteries for stop&go and dual battery systems

    Science.gov (United States)

    May, G. J.; Calasanzio, D.; Aliberti, R.

    The electrical power requirements for vehicles are continuing to increase and evolve. A substantial amount of effort has been directed towards the development of 36/42 V systems as a route to higher power with reduced current levels but high implementation costs have resulted in the introduction of these systems becoming deferred. In the interim, however, alternator power outputs at 14 V are being increased substantially and at the same time the requirements for batteries are becoming more intensive. In particular, stop&go systems and wire-based vehicle systems are resulting in new demands. For stop&go, the engine is stopped each time the vehicle comes to rest and is restarted when the accelerator is pressed again. This results in an onerous duty cycle with many shallow discharge cycles. Flooded lead-acid batteries cannot meet this duty cycle and valve-regulated lead-acid (VRLA) batteries are needed to meet the demands that are applied. For wire-based systems, such as brake-by-wire or steer-by-wire, electrical power has become more critical and although the alternator and battery provide double redundancy, triple redundancy with a small reserve battery is specified. In this case, a small VRLA battery can be used and is optimised for standby service rather than for repeated discharges. The background to these applications is considered and test results under simulated operating conditions are discussed. Good performance can be obtained in batteries adapted for both applications. Battery management is also critical for both applications: in stop&go service, the state-of-charge (SOC) and state-of-health (SOH) need to be monitored to ensure that the vehicle can be restarted; for reserve or back-up batteries, the SOC and SOH are monitored to verify that the battery is always capable of carrying out the duty cycle if required. Practical methods of battery condition monitoring will be described.

  17. Data-driven battery product development: Turn battery performance into a competitive advantage.

    Energy Technology Data Exchange (ETDEWEB)

    Sholklapper, Tal [Voltaiq, Inc.

    2016-04-19

    Poor battery performance is a primary source of user dissatisfaction across a broad range of applications, and is a key bottleneck hindering the growth of mobile technology, wearables, electric vehicles, and grid energy storage. Engineering battery systems is difficult, requiring extensive testing for vendor selection, BMS programming, and application-specific lifetime testing. This work also generates huge quantities of data. This presentation will explain how to leverage this data to help ship quality products faster using fewer resources while ensuring safety and reliability in the field, ultimately turning battery performance into a competitive advantage.

  18. Battery System Modeling for a Military Electric Propulsion Vehicle with a Fault Simulation

    Directory of Open Access Journals (Sweden)

    Hyeongcheol Lee

    2013-10-01

    Full Text Available This paper describes the development process and results of a battery system model with a fault simulation for electric propulsion vehicles. The developed battery system model can be used to verify control and fault diagnosis strategies of the supervisory controller in an electric propulsion vehicle. To develop this battery system model, three sub-models, including a battery model, a relay assembly model, and a battery management system (BMS model, are connected together like in the target real battery system. Comparison results between the real battery system hardware and the battery system model show a similar tendency and values. Furthermore, the fault injection test of the model shows that the proposed battery system model can simulate a failure situation consistent with a real system. It is possible for the model to emulate the battery characteristics and fault situation if it is used in the development process of a BMS or for supervisory control strategies for electric propulsion systems.

  19. Neglected dorsal dislocation of the scaphoid

    Directory of Open Access Journals (Sweden)

    Amaravati Rajkumar

    2009-01-01

    Full Text Available Isolated dislocation of the scaphoid is very rare. A 45-year old male, industrial worker reported two and half months after injury with wrist pain and swelling on the dorsum of left wrist. He was diagnosed as neglected dorsal dislocation of scaphoid. Proximal row carpectomy with capsular interposition was done stabilizing the distal carpus on the radius using Kirschner wires. At-12 months follow-up the patient had good wrist function and was satisfied with the outcome of the treatment. We hereby report this neglected dorsal dislocation of scaphoid in view of rarity and discuss the various options for management.

  20. Development and field test of psychophysical tests for DWI arrest

    Science.gov (United States)

    1981-03-01

    Administration and scoring procedures were standardized for a sobriety test battery consisting of the walk-and-turn test, the one leg stand test, and horizontal gaze nystagmus. The effectiveness of the standardized battery was then evaluated in the l...

  1. Somatosensory Impairments in the Upper Limb Poststroke: Distribution and Association With Motor Function and Visuospatial Neglect.

    Science.gov (United States)

    Meyer, Sarah; De Bruyn, Nele; Lafosse, Christophe; Van Dijk, Margaretha; Michielsen, Marc; Thijs, Liselot; Truyens, Veronik; Oostra, Kristine; Krumlinde-Sundholm, Lena; Peeters, Andre; Thijs, Vincent; Feys, Hilde; Verheyden, Geert

    2016-09-01

    A thorough understanding of the presence of different upper-limb somatosensory deficits poststroke and the relation with motor performance remains unclear. Additionally, knowledge about the relation between somatosensory deficits and visuospatial neglect is limited. To investigate the distribution of upper-limb somatosensory impairments and the association with unimanual and bimanual motor outcomes and visuospatial neglect. A cross-sectional observational study was conducted, including 122 patients within 6 months after stroke (median = 82 days; interquartile range = 57-133 days). Somatosensory measurement included the Erasmus MC modification of the (revised) Nottingham Sensory Assessment (Em-NSA), Perceptual Threshold of Touch (PTT), thumb finding test, 2-point discrimination, and stereognosis subscale of the NSA. Upper-limb motor assessment comprised the Fugl-Meyer assessment, motricity index, Action Research Arm Test, and Adult-Assisting Hand Assessment Stroke. Screening for visuospatial neglect was performed using the Star Cancellation Test. Upper-limb somatosensory impairments were common, with prevalence rates ranging from 21% to 54%. Low to moderate Spearman ρ correlations were found between somatosensory and motor deficits (r = 0.22-0.61), with the strongest associations for PTT (r = 0.56-0.61) and stereognosis (r = 0.51-0.60). Visuospatial neglect was present in 27 patients (22%). Between-group analysis revealed somatosensory deficits that occurred significantly more often and more severely in patients with visuospatial neglect (P visuospatial neglect (r = 0.44-0.78) compared with patients without neglect (r = 0.08-0.59). Somatosensory impairments are common in subacute patients poststroke and are related to motor outcome. Visuospatial neglect was associated with more severe upper-limb somatosensory impairments. © The Author(s) 2015.

  2. Common brain networks for distinct deficits in visual neglect. A combined structural and tractography MRI approach.

    Science.gov (United States)

    Toba, Monica N; Migliaccio, Raffaella; Batrancourt, Bénédicte; Bourlon, Clémence; Duret, Christophe; Pradat-Diehl, Pascale; Dubois, Bruno; Bartolomeo, Paolo

    2017-10-18

    Visual neglect is a heterogeneous, multi-component syndrome resulting from right hemisphere damage. Neglect patients do not pay attention to events occurring on their left side, and have a poor functional outcome. The intra-hemispheric location of lesions producing neglect is debated, because studies using different methods reported different locations in the grey matter and in the white matter of the right hemisphere. These reported locations show various patterns of overlapping with the fronto-parietal attention networks demonstrated by functional neuroimaging. We explored the anatomical correlates of neglect patients' performance on distinct tests of neglect. For the first time in neglect anatomy studies, we individually assessed 25 patients with subacute strokes in the right hemisphere, by using a combined structural and diffusion tensor deterministic tractography approach, with separate analyses for each neglect test. The results revealed that lesions in nodes of the ventral attention network (angular and supramarginal gyri) were selectively associated with deficits in performance on all the tests used; damage to other structures correlated with impaired performance on specific tests, such as the bells test (middle and inferior frontal gyri), or the reading test (temporal regions). Importantly, however, white matter damage proved crucial in producing neglect-related deficits. Voxel-based lesion-symptom mapping (VLSM) and tractography consistently revealed that damage to the ventral branch of the superior longitudinal fasciculus (SLF III) and to the inferior fronto-occipital fasciculus (IFOF) predicted pathological scores on line bisection/drawing copy and on the bells test, respectively. Moreover, damage to distinct sectors of SLF III, or combined SLF/IFOF damage, gave rise to different performance profiles. Our results indicate that both grey and white matter lesion analysis must be taken into account to determine the neural correlates of neglect

  3. Computing Battery Lifetime Distributions

    NARCIS (Netherlands)

    Cloth, L.; Haverkort, Boudewijn R.H.M.; Jongerden, M.R.

    The usage of mobile devices like cell phones, navigation systems, or laptop computers, is limited by the lifetime of the included batteries. This lifetime depends naturally on the rate at which energy is consumed, however, it also depends on the usage pattern of the battery. Continuous drawing of a

  4. Deep diode atomic battery

    International Nuclear Information System (INIS)

    Anthony, T.R.; Cline, H.E.

    1977-01-01

    A deep diode atomic battery is made from a bulk semiconductor crystal containing three-dimensional arrays of columnar and lamellar P-N junctions. The battery is powered by gamma rays and x-ray emission from a radioactive source embedded in the interior of the semiconductor crystal

  5. Battery energy storage system

    NARCIS (Netherlands)

    Tol, C.S.P.; Evenblij, B.H.

    2009-01-01

    The ability to store electrical energy adds several interesting features to a ships distribution network, as silent power, peak shaving and a ride through in case of generator failure. Modern intrinsically safe Li-ion batteries bring these within reach. For this modern lithium battery applications

  6. Sodium sulfur batteries for space applications

    Science.gov (United States)

    Degruson, James A.

    1992-02-01

    In 1986, Eagle-Picher Industries was selected by the Air Force to develop sodium sulfur cells for satellite applications. Specifically, the development program was geared toward low earth orbit goals requiring high charge and/or discharge rates. A number of improvements have been made on the cell level and a transition to a complete space battery was initiated at Eagle-Picher. The results of six months of testing a 250 watt/hour sodium sulfur space battery look very promising. With over 1000 LEO cycles conducted on this first battery, the next generation battery is being designed. This next design will focus on achieving greater energy densities associated with the sodium sulfur chemistry.

  7. Raynaud's Syndrome: a neglected disease.

    Science.gov (United States)

    Poredos, Pavel; Poredos, Peter

    2016-04-01

    Raynaud's Syndrome is a frequent manifestation of digital ischemia which occurs or is aggravated upon exposure to cold temperatures or emotional distress. Primary Raynaud is a benign disease which predominantly affects younger women and is transient without serious sequelae. In contrast, secondary Raynaud is usually one of the manifestations of systemic disease and is, in addition to symptoms of the basic disease, associated with ischemic lesions. The diagnosis of primary Raynaud is mostly based on the clinical presentation. In secondary Raynaud, additional investigating techniques including imaging investigations and laboratory tests for the detection of underline disease are needed. Treatment is based on lifestyle modification, which includes smoking cessation, avoiding low outside temperatures, avoiding the use of vibrating tools and limiting repeated hand actions. Drug treatment consists of calcium-channel blockers, nitroglycerine ointments, prostacyclins and various new drugs such as endothelin receptor antagonists, phosphodiesterase inhibitors and serotonin receptor antagonists. Most of these drugs are effective in less than 50% of treated patients and do not completely abolish vasospastic attacks, but reduce the severity and frequency of attacks. The prostacyclin derivate iloprost is the most promising drug in the management of secondary Raynaud's disease. Other therapeutic procedures including chemical or surgical sympathectomy are obsolete and without any long-term positive effects.

  8. EDITORIAL Drugs for Neglected Diseases Initiative

    African Journals Online (AJOL)

    Dr.Kofi-Tsekpo

    organisation with headquarters in Geneva, Switzerland. Founded by six research institutions and an international humanitarian organisation*, DNDi addresses the need for new field-adapted, effective, and affordable drugs for patients suffering from neglected diseases. DNDi harnesses knowledge and cutting-edge science.

  9. Child Abuse and Neglect. Data Snapshot

    Science.gov (United States)

    DC Action for Children, 2011

    2011-01-01

    The number of substantiated cases of child abuse and neglect in the District rose by 27 percent in FY 2009. This dramatic spike came after two consecutive years of decline in the number of substantiated cases reported the D.C. Child and Family Services Agency (CFSA). In FY 2010, the number of closed, substantiated cases dropped back down to 1,691,…

  10. Social capital, family violence, and neglect.

    Science.gov (United States)

    Zolotor, Adam J; Runyan, Desmond K

    2006-06-01

    Social capital includes collective efficacy, psychological sense of community, neighborhood cohesion, and parental investment in the child. It has been shown to be associated with a variety of health and welfare outcomes and may be useful in understanding and preventing parenting behaviors on the continuum of child abuse and neglect. The purpose of this research was to evaluate low social capital as a risk factor for harsh physical punishment, neglectful parenting, psychologically harsh parenting, and domestic violence. This study is an analysis of cross-sectional telephone survey data of mothers in North and South Carolina (n = 1435). We constructed a 4-point social capital index reflecting survey responses to items ascertaining neighborhood characteristics, willingness to take personal action, the presence of 2 adults in the household, and regular religious service participation. We assessed the relationship of social capital to inventories of self-reported parenting behaviors and in-home violence. In adjusted analysis, we found that each 1 point increase in a 4-point social capital index was associated with a 30% reduction in the odds of neglectful parenting, psychologically harsh parenting, and domestic violence. There was no relationship between social capital and harsh physical punishment. This study demonstrates that increasing social capital decreases the odds of neglectful parenting, psychologically harsh parenting, and domestic violence but not harsh physical punishment. This supports further investigation into developing social capital as a resource for families.

  11. How Neglect and Punitiveness Influence Emotion Knowledge

    Science.gov (United States)

    Sullivan, Margaret Wolan; Carmody, Dennis P.; Lewis, Michael

    2010-01-01

    To explore whether punitive parenting styles contribute to early-acquired emotion knowledge deficits observable in neglected children, we observed 42 preschool children's emotion knowledge, expression recognition time, and IQ. The children's mothers completed the Parent-Child Conflict Tactics Scales to assess the recent use of three types of…

  12. EDITORIAL Neglected Diseases: Burden and attention

    African Journals Online (AJOL)

    Preferred Customer

    Neglected diseases are largely infectious diseases that have burdened humanity for centuries, but currently receiving little attention. Infectious diseases in their long histories have resulted in considerable morbidities, disabilities and deformities, often subjecting to stigma. The magnitude of their impact on health and labor.

  13. Performance management: the neglected imperative of ...

    African Journals Online (AJOL)

    As part of the qualitative research design, the individual interview was selected for use in this research. Fifteen participants drawn randomly from 24 schools were interviewed. The findings revealed the weakness of integrating development with appraisal since it leads to the neglect of development in favour of appraisal ...

  14. Urine-activated paper batteries for biosystems

    Science.gov (United States)

    Bang Lee, Ki

    2005-09-01

    The first urine-activated laminated paper batteries have been demonstrated and reported in this paper. A simple and cheap fabrication process for the paper batteries has been developed which is compatible with the existing plastic laminating technologies or plastic molding technologies. In this battery, a magnesium (Mg) layer and copper chloride (CuCl) in the filter paper are used as the anode and the cathode, respectively. A stack consisting of a Mg layer, CuCl-doped filter paper and a copper (Cu) layer sandwiched between two plastic layers is laminated into the paper batteries by passing through the heating roller at 120 °C. The paper battery is tested and it can deliver a power greater than 1.5 mW. In addition, these urine-activated laminated paper batteries could be integrated with bioMEMS devices such as home-based health test kits providing a power source for the electronic circuit. A portion of this paper was presented at The 4th International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS 2004), 28 30 November, 2004, Kyoto, Japan.

  15. Battery Pack Thermal Design

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad

    2016-06-14

    This presentation describes the thermal design of battery packs at the National Renewable Energy Laboratory. A battery thermal management system essential for xEVs for both normal operation during daily driving (achieving life and performance) and off-normal operation during abuse conditions (achieving safety). The battery thermal management system needs to be optimized with the right tools for the lowest cost. Experimental tools such as NREL's isothermal battery calorimeter, thermal imaging, and heat transfer setups are needed. Thermal models and computer-aided engineering tools are useful for robust designs. During abuse conditions, designs should prevent cell-to-cell propagation in a module/pack (i.e., keep the fire small and manageable). NREL's battery ISC device can be used for evaluating the robustness of a module/pack to cell-to-cell propagation.

  16. A Novel Electric Bicycle Battery Monitoring System Based on Android Client

    Directory of Open Access Journals (Sweden)

    Chuanxue Song

    2017-01-01

    Full Text Available The battery monitoring system (BMS plays a crucial role in maintaining the safe operation of the lithium battery electric bicycle and prolonging the life of the battery pack. This paper designed a set of new battery monitoring systems based on the Android system and ARM single-chip microcomputer to enable direct management of the lithium battery pack and convenient monitoring of the state of the battery pack. The BMS realizes the goal of monitoring the voltage, current, and ambient temperature of lithium batteries, estimating the state of charge (SOC and state of health (SOH, protecting the battery from abuse during charging or discharging, and ensuring the consistency of the batteries by integrating the passive equalization circuit. The BMS was proven effective and feasible through several tests, including charging/discharging, estimation accuracy, and communication tests. The results indicated that the BMS could be used in the design and application of the electric bicycle.

  17. The Predictive Nature of Pseudoneglect for Visual Neglect: Evidence from Parietal Theta Burst Stimulation.

    Directory of Open Access Journals (Sweden)

    Alice Varnava

    Full Text Available Following parietal damage most patients with visual neglect bisect horizontal lines significantly away from the true centre. Neurologically intact individuals also misbisect lines; a phenomenon referred to as 'pseudoneglect'. In this study we examined the relationship between neglect and pseudoneglect by testing how patterns of pre-existing visuospatial asymmetry predict asymmetry caused by parietal interference. Twenty-four participants completed line bisection and Landmark tasks before receiving continuous theta burst stimulation to the left or right angular gyrus. Results showed that a pre-existing pattern of left pseudoneglect (i.e. right bias, but not right pseudoneglect, predicts left neglect-like behaviour during line bisection following right parietal cTBS. This correlation is consistent with the view that neglect and pseudoneglect arise via a common or linked neural mechanism.

  18. Improvement of Mental Imagery after Prism Exposure in Neglect: A Case Study

    Directory of Open Access Journals (Sweden)

    Gilles Rode

    1999-01-01

    Full Text Available Previous work has shown that various symptoms of unilateral neglect, including the pathological shift of the subjective midline to the right, may be improved by a short adaptation period to a prismatic shift of the visual field to the right. We report here the improvement of imagined neglect after prism exposure in a patient with a left unilateral neglect. Despite a strong neglect observed for mental images as well as for conventional tests, the mental evocation of left-sided information from an internal image of the map of France map was fully recovered following prism adaptation to the right. This improvement could not be explained by the alteration of visuomotor responses induced by the prism adaptation. Prism adaptation may therefore act not only on sensory-motor levels but also on a higher cognitive level of mental space representation and/or exploration.

  19. A review of nickel hydrogen battery technology

    Science.gov (United States)

    Smithrick, John J.; Odonnell, Patricia M.

    1995-01-01

    This paper on nickel hydrogen batteries is an overview of the various nickel hydrogen battery design options, technical accomplishments, validation test results and trends. There is more than one nickel hydrogen battery design, each having its advantage for specific applications. The major battery designs are individual pressure vessel (IPV), common pressure vessel (CPV), bipolar and low pressure metal hydride. State-of-the-art (SOA) nickel hydrogen batteries are replacing nickel cadmium batteries in almost all geosynchronous orbit (GEO) applications requiring power above 1 kW. However, for the more severe low earth orbit (LEO) applications (greater than 30,000 cycles), the current cycle life of 4000 to 10,000 cycles at 60 percent DOD should be improved. A NASA Lewis Research Center innovative advanced design IPV nickel hydrogen cell led to a breakthrough in cycle life enabling LEO applications at deep depths of discharge (DOD). A trend for some future satellites is to increase the power level to greater than 6 kW. Another trend is to decrease the power to less than 1 kW for small low cost satellites. Hence, the challenge is to reduce battery mass, volume and cost. A key is to develop a light weight nickel electrode and alternate battery designs. A common pressure vessel (CPV) nickel hydrogen battery is emerging as a viable alternative to the IPV design. It has the advantage of reduced mass, volume and manufacturing costs. A 10 Ah CPV battery has successfully provided power on the relatively short lived Clementine Spacecraft. A bipolar nickel hydrogen battery design has been demonstrated (15,000 LEO cycles, 40 percent DOD). The advantage is also a significant reduction in volume, a modest reduction in mass, and like most bipolar designs, features a high pulse power capability. A low pressure aerospace nickel metal hydride battery cell has been developed and is on the market. It is a prismatic design which has the advantage of a significant reduction in volume and a

  20. Child Abuse and Neglect in India.

    Science.gov (United States)

    Seth, Rajeev

    2015-08-01

    India is home to the largest child population in the world, with almost 41 % of the total population under 18 y of age. The health and security of the country's children is integral to any vision for its progress and development. Doctors and health care professionals are often the first point of contact for abused and neglected children. They play a key role in detecting child abuse and neglect, provide immediate and longer term care and support to children. Despite being important stakeholders, often physicians have a limited understanding on how to protect these vulnerable groups. There is an urgent need for systematic training for physicians to prevent, detect and respond to cases of child abuse and neglect in the clinical setting. The purpose of the present article is to provide an overview of child abuse and neglect from a medical assessment to a socio-legal perspective in India, in order to ensure a prompt and comprehensive multidisciplinary response to victims of child abuse and neglect. During their busy clinical practice, medical professionals can also use the telephone help line (CHILDLINE telephone 1098) to refer cases of child abuse, thus connecting them to socio-legal services. The physicians should be aware of the new legislation, Protection of Children from Sexual Offences (POCSO) Act, 2012, which requires mandatory reporting of cases of child sexual abuse, failing which they can be penalized. Moreover, doctors and allied medical professionals can help prevent child sexual abuse by delivering the message of personal space and privacy to their young patients and parents.