WorldWideScience

Sample records for negative diagnostic iodine-123

  1. Iodine-123 (123I) is promising radiopharmaceutical in the radionuclide diagnostics

    International Nuclear Information System (INIS)

    Tazhedinov, I.T.

    2003-01-01

    In the paper some advantages of the radiopharmaceuticals with 123 I against 99m Tc preparations are shown. It is noted that the 123 I is the most favourable among cyclotron radionuclides for radionuclide diagnostics by it nuclear-physical characteristics. With application of 123 I it is possible to attain a significant progress in the thyroid examination. 123 I labelled preparations should have a high bond strength providing the high information valuation of examinations

  2. Industrial system for producing iodine-123

    International Nuclear Information System (INIS)

    Brantley, J.C.

    1985-01-01

    An industrial system to produce iodine-123 required a complex set of steps involving new approaches by the Food and Drug Administration, difficult distribution procedures, and evidence from potential users that either very pure iodine-123 or inexpensive iodine-123 is needed. Industry has shown its willingness to invest in new radionuclides but needs strong evidence as to product potential to justify those investments

  3. Iodine-123 in Western Europe

    International Nuclear Information System (INIS)

    Qaim, S.M.; Stoecklin, G.; Weinreich, R.

    1976-08-01

    The major object of this panel was to obtain information on the state of art of Iodine-123 production in Western Europe. Technical, medical and organizational problems were discussed extensively during the one-day meeting and a stimulating exchange of information between the various 123 I-producers and users has been initiated. Some specific examples of medical application were also included in order to get a feeling of the degree of acceptance by the medical community and the demand for this isotope. The meeting clearly demonstrated the great demand for this isotope but it also showed that the present rate of production is well below the demand. In order to fill this gap, not only further technical development is needed but also the organizational question of distribution has to be solved, perhaps within a network of collaborating cyclotrons, a task which is considerably more difficult in Western Europe than in the USA. (orig./HP) [de

  4. Iodine-123-labelled serum amyloid P component scintigraphy in amyloidosis

    International Nuclear Information System (INIS)

    Saile, R.; Deveaux, M.; Marchandise, X.; Duquesnoy, B.

    1993-01-01

    This study describes the results of scintigraphy with iodine-123-labelled serum amyloid P component (SAP) as a means of establishing the distribution of organ involvement in amyloidosis. The significance of 123 I-SAP scans obtained in 15 patients with biopsy-proven AA or AL amyloidosis is discussed. Biopsy-proven amyloidosis was typically confirmed by scintigraphy, though such confirmation was not obtained in the kidneys in six patients with histological proof of extensive renal amyloid deposition. This lack of uptake may have been due to the accumulation of a major part of the 123 I-SAP in the spleen and/or liver. Twenty-four hour whole-body retention of 123 I-SAP was higher in patients with amyloidosis than in controls. Twenty-four hour tracer accumulation of the radioactivity in the extravascular compartment was notably greater in patients than in controls and appeared to be a good diagnostic criterion. We conclude that 123 I-SAP scintigraphy may be helpful for the evaluation of organ involvement not only in patients with biopsy-proven amyloidosis but also when a biopsy cannot be performed or when a strong suspicion of amyloidosis exists in spite of repeated negative biopsises. (orig.)

  5. Iodine-123 program at the TRIUMF laboratory

    International Nuclear Information System (INIS)

    Vincent, J.S.

    1985-01-01

    A research program for the production and utilization of iodine-123 is described. From 1979 to 1982 the spallation of elemental cesium by 500-MeV protons was used to provide 100 mCi/hr at the end of bombardment (EOB). Contaminants were 3% iodine-125 and 0.15% tellurium-121 at EOB + 36 hr. The material from weekly runs was used by remote clinics in Canada for evaluation as a radiochemical and for labeling studies. A new facility at TRIUMF will be operational in 1983 to produce iodine-123 by the (p,5n) reaction

  6. Quantitative SPECT reconstruction of iodine-123 data

    International Nuclear Information System (INIS)

    Gilland, D.R.; Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1991-01-01

    Many clinical and research studies in nuclear medicine require quantitation of iodine-123 ( 123 I) distribution for the determination of kinetics or localization. The objective of this study was to implement several reconstruction methods designed for single-photon emission computed tomography (SPECT) using 123 I and to evaluate their performance in terms of quantitative accuracy, image artifacts, and noise. The methods consisted of four attenuation and scatter compensation schemes incorporated into both the filtered backprojection/Chang (FBP) and maximum likelihood-expectation maximization (ML-EM) reconstruction algorithms. The methods were evaluated on data acquired of a phantom containing a hot sphere of 123 I activity in a lower level background 123 I distribution and nonuniform density media. For both reconstruction algorithms, nonuniform attenuation compensation combined with either scatter subtraction or Metz filtering produced images that were quantitatively accurate to within 15% of the true value. The ML-EM algorithm demonstrated quantitative accuracy comparable to FBP and smaller relative noise magnitude for all compensation schemes

  7. Gas-target method for the production of iodine-123

    International Nuclear Information System (INIS)

    Robertson, R.; Stuart, D.C.

    1986-01-01

    The object of this invention is to provide a means of producing iodine-123 in high yield and purity via a small accelerator. The process uses protons of about 30 MeV incident upon a target of isotopically-enriched xenon-124 gas. The product obtained has a useful life after preparation of at least 85 hours

  8. An economical method for the continuous production of iodine-123

    Science.gov (United States)

    Blue, J. W.; Smith, W. R.; Sodd, V. J.

    1968-01-01

    Simple and inexpensive method produces iodine 123, in a conventional cyclotron. Tellurium 122, a stable isotope available in enrichments exceeding 95 percent, is held on a porous metal plate by a flowing stream of helium and bombarded with either alpha particles or helium 3.

  9. Labeling of indocyanine green with carrier-free iodine-123

    International Nuclear Information System (INIS)

    Ansari, A.N.; Lambrecht, R.M.; Redvanly, C.S.; Wolf, A.P.

    1976-01-01

    The method is described for labeling indocyanine green (ICG) with carrier-free iodine-123 by condensing xenon-123 on crystals of ICG followed by permitting decay of the 123 Xe a sufficient length of time to produce 123 I-electronically excited ions and atoms which subsequently label ICG. 4 claims, no drawings

  10. Medical necessity for shorter lived radionuclides, specifically pure Iodine-123

    International Nuclear Information System (INIS)

    DeNardo, G.L.; DeNardo, S.J.; Hines, H.H.; Lagunas-Solar, M.C.; Jungerman, J.A.

    1985-01-01

    Iodine-123 has physical and radiochemical characteristics ideal for most tracer procedures performed in patients. Its use is generally preferable to the use of 131 I for diagnosis. The potential for 123 I can be realized only if a radiopharmaceutical of lesser radionuclide contamination is generally and economically available. Iodine-123 produced by direct methods has significant disadvantages relative to quality of procedure and radiation dosimetry. Our experience with 123 I(p,5n) during the past 12 years causes us to vigorously encourage general availability of an 123 I radiopharmaceutical of this quality. Using this product, the authors have prepared radiopharmaceuticals for use in the study of cancer, coagulation, and renal and thyroid diseases

  11. Iodine 123-antipyrine. A diffusible tracer for brain exploration

    International Nuclear Information System (INIS)

    Dantonel-Mathieu, Evelyne.

    1978-09-01

    Iodine 123-labelled iodoantipyrine is a liposoluble diffusible tracer which crosses the blood-brain barrier intact. Its build-up in brain tissue is proportional to the regional blood flow. Its behavior was studied in undervascularised brain lesions and in cases where research with traditional radioactive tracers (99mTc and its different vectors for example) has proved limited. Because of the great diffusibility of iodoantipyrine a brain parenchyma image is obtained within minutes after its injection, and this by the use of a non-invasive technique and under good gamma-camera exploration conditions. 81 brain explorations including 11 standards have been carried out on subjects averaging 51,2 years old; these examinations took place in three nuclear medicine centres. The 123 I iodoantipyrine used in each nuclear medicine centre is supplied by the CEA. Iodoantipyrine is labelled with a good yield (>98%) checked by chromatography by means of a CEA kit. After intraveinous injection of 4 to 6 mCi iodine-123 iodoantipyrine, a dynamic study (from 0 to 60 seconds) of the tracer passage in the brain tissue may be followed by static images taken in the next minutes according to a standard procedure. The table of results shows the major interest of this tracer for the exploration of vascular accidents with ischemic lesions, especially in the early phase of the accident. The lesion appears as a hypoactive zone and this lack of perfusion lasts for some minutes after the injection [fr

  12. Dosimetry of iodine-123 for newborn and infant

    International Nuclear Information System (INIS)

    Guilhem, M.T.; Therain, F.

    1987-01-01

    Iodine-123 ( 123 I) is a radionuclide of choice of neonatal hypothyroidism diagnosis. It is important to know infant main organs adsorbed doses during a thyroid scan with 123 I. Absorbed doses are already available for adults: for infants, they must be transformed taking account of organs sizes and inter-organs distances. Calculations are done for commercially available 123 I(p,2n) and 123 I(p,5n). Important contamination of 124 I in 123 I(p,2n) increases considerably the absorbed-dose during thyroid scan of a newborn (the ratio 124 I/ 123 I doubles every 15h). For routinely used activities, thyroid absorbed dose, 24 h after end of production, is fifteen times higher with 123 I(p,5n) than with 99m Tc: for one month old child; total body absorbed dose is of the same order of magnitude [fr

  13. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.; Goodman, M.M.

    1993-01-01

    Continuous interest in the use of iodine-123-labeled fatty acids for myocardial imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-123-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability makers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT). (author)

  14. Uptake of iodine-123-α-methyl tyrosine by gliomas and non-neoplastic brain lesions

    International Nuclear Information System (INIS)

    Kuwert, T.; Morgenroth, C.; Woesler, B.; Matheja, P.; Palkovic, S.; Vollet, B.; Samnick, S.; Maasjosthusmann, U.; Lerch, H.; Gildehaus, F.J.; Wassmann, H.; Schober, O.

    1996-01-01

    Using single-photon emission tomography (SPET), the radiopharmaceutical L-3-iodine-123-α-methyl tyrosine (IMT) has been applied to the imaging of amino acid transport into brain tumours. It was the aim of this study to investigate whether IMT SPET is capable of differentiating between high-grade gliomas, low-grade gliomas and non-neoplastic brain lesions. To this end, IMT uptake was determined in 53 patients using the triple-headed SPET camera MULTISPECT 3. Twenty-eight of these subjects suffered from high-grade gliomas (WHO grade III or IV), 12 from low-grade gliomas (WHO grade II), and 13 from non-neoplastic brain lesions, including lesions after effective therapy of a glioma (five cases), infarctions (four cases), inflammatory lesions (three cases), infarctions (four cases), inflammatory lesions (three cases) and traumatic haematoma (one case). IMT uptake was significantly higher in high-grade gliomas than in low-grade gliomas and non-neoplastic lesions. IMT uptake by low-grade gliomas was not significantly different from that by non-neoplastic lesions. Diagnostic sensitivity and specificity were 71% and 83% for differentiating high-grade from low-grade gliomas, 82% and 100% for distinguishing high-grade gliomas from non-neoplastic lesions, and 50% and 100% for discriminating low-grade gliomas from non-neoplastic lesions. Analogously to positron emission tomography with radioactively labelled amino acids and fluorine-18 deoxyglucose, IMT SPET may aid in differentiating higc-grade gliomas from histologically benign brain tumours and non-neoplastic brain lesions; it is of only limited value in differentiating between non-neoplastic lesions and histologically benign brain tumours. (orig.)

  15. Iodine-123 lodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism

    International Nuclear Information System (INIS)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Collier, T.L.; Cardaci, G.; Davis, S.; Laing, B.; Mastaglia, F.L.; O'Brien, J.; ANSTO, Lucas Heights, NSW,

    1997-01-01

    Full text; The clinical distinction between idiopathic Parkinson's disease (IPD) and other neurodegenerative disorders which mimic this condition is important in patient management. Iodine-123 lodobenzamide (IBZM) SPECT imaging of cerebral dopamine-2 (D 2 ) receptors has been proposed as a means of distinguishing between IPD and atypical variants, including such Parkinsonian syndromes (PS) as multi-system atrophy and progressive supranuclear palsy, and to predict long-term responsiveness to dopaminergic drugs. Apomorphine testing is currently in use for the latter purpose. To assess the role of IBZM SPECT, MRI and apomorphine testing in categorising patients with Parkinsonian symptoms and for predicting therapeutic response, we studied 40 subjects, 18 of whom had IPD. SPECT brain studies were carried out two hours after the intravenous injection of approximately 185 MBq of 123 I IBZM. Semiquantitative IBZM striatal/occipital cortex uptake ratios in the IPD group were 1.53 + 0.17 (mean + S.D.), and in the non-lPD group 1.53 ± 0.29. Of the 11 IPD patients and 19 non-lPD patients who had MRI, none and two, respectively, showed iron deposition in the basal ganglia. Eleven of 13 IPD and 3 of 18 non-lPD subjects had a positive apomorphine test, while 15 of 15 IPD and 5 of 19 non-lPD subjects responded to dopaminergic therapy. When patients were classified into responders (R) (n 20) and non-responders (NR) (n = 14), the IBZM ratios were 1.56 ± 0.22 and 1.47 ± 0.29 respectively (no significant difference between the groups). The apomorphine test accurately predicted response, being positive in 13 of 15 R and negative in 11 of 12 NR. We conclude that 123 I SPECT is not helpful in differentiating IPD from PS, nor in predicting response to dopaminergic drugs

  16. Iodine-123 lodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism.

    Energy Technology Data Exchange (ETDEWEB)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Collier, T.L.; Cardaci, G.; Davis, S.; Laing, B.; Mastaglia, F.L.; O`Brien, J. [Sir Charles Gairdner Hospital, Perth, WA, (Australia)]|[ANSTO, Lucas Heights, NSW, (Australia). The Biomedicine and Health Program

    1997-09-01

    Full text; The clinical distinction between idiopathic Parkinson`s disease (IPD) and other neurodegenerative disorders which mimic this condition is important in patient management. Iodine-123 lodobenzamide (IBZM) SPECT imaging of cerebral dopamine-2 (D{sub 2}) receptors has been proposed as a means of distinguishing between IPD and atypical variants, including such Parkinsonian syndromes (PS) as multi-system atrophy and progressive supranuclear palsy, and to predict long-term responsiveness to dopaminergic drugs. Apomorphine testing is currently in use for the latter purpose. To assess the role of IBZM SPECT, MRI and apomorphine testing in categorising patients with Parkinsonian symptoms and for predicting therapeutic response, we studied 40 subjects, 18 of whom had IPD. SPECT brain studies were carried out two hours after the intravenous injection of approximately 185 MBq of {sup 123}I IBZM. Semiquantitative IBZM striatal/occipital cortex uptake ratios in the IPD group were 1.53 + 0.17 (mean + S.D.), and in the non-lPD group 1.53 {+-} 0.29. Of the 11 IPD patients and 19 non-lPD patients who had MRI, none and two, respectively, showed iron deposition in the basal ganglia. Eleven of 13 IPD and 3 of 18 non-lPD subjects had a positive apomorphine test, while 15 of 15 IPD and 5 of 19 non-lPD subjects responded to dopaminergic therapy. When patients were classified into responders (R) (n 20) and non-responders (NR) (n = 14), the IBZM ratios were 1.56 {+-} 0.22 and 1.47 {+-} 0.29 respectively (no significant difference between the groups). The apomorphine test accurately predicted response, being positive in 13 of 15 R and negative in 11 of 12 NR. We conclude that {sup 123}I SPECT is not helpful in differentiating IPD from PS, nor in predicting response to dopaminergic drugs.

  17. The development of iodine-123-labeled-methyl-branched fatty acids for myocardial SPECT imaging

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.

    1994-01-01

    Iodine-123-labeled fatty acids represent unique metabolic probes for correlation of energy substrate metabolism with regional myocardial viability. Interest in the use of these agents results from differences which are often observed in various types of heart disease between regional myocardial fatty acid uptake patterns and flow tracer distribution. Although the physiological basis is not completely understood, differences between regional fatty acid and flow tracer distribution may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. The iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue was developed at the Oak Ridge National Laboratory and was recently introduced as ''Cardiodine trademark'' in 1993 by Nihon Medi-Physics for commercial distribution in Japan. Iodine-123-BMPP is also being used in clinical studies on an institutional approval basis at several institutions in Europe and the US. This paper describes the development of the concept of fatty acid ''metabolic trapping'' of methyl-branched fatty acids and their use for single photon emission computerized tomographic cardiac imaging

  18. Quantitative renal cinescintigraphy with iodine-123 hippuran methodological aspects, kit for labeling of hippuran

    International Nuclear Information System (INIS)

    Mehdaoui, A.; Pecking, A.; Delorme, G.; Mathonnat, F.; Debaud, B.; Bardy, A.; Coornaert, S.; Merlin, L.; Vinot, J.M.; Desgrez, A.; Gambini, D.; Vernejoul, P. de.

    1981-08-01

    The development of an extemporaneous kit for the labeling of ortho-iodo-hippuric acid (Hippuran) with iodine 123 allows the performance of a routine quantitative renal cinescintigraphy providing in 20 minutes, and in an absolutely non-traumatic way, a very complete renal morphofunctional study including: a cortical renal scintigraphy, sequential scintigraphies of excretory tract, renal functional curves, tubular, global, and separate clearances for each kidney. This functional quantitative investigation method should take a preferential place in the routine renal balance. The methodology of the technique is explained and compared to classical methods for estimation of tubular, global and separate clearances [fr

  19. Iodine-123 and bromine-75 production and development program at Juelich

    International Nuclear Information System (INIS)

    Stoecklin, G.

    1985-01-01

    The iodine-123 and bromine-75 production and development program at the Nuclear Research Center in Juelich as of 1982 is described, and examples of recent 123 I- and 75 Br-analogue tracers that have been developed to the level of clinical trial are given. Iodine-123 is produced via the 127 I(d,6n) 123 Xe → 123 I process and by the 124 Te(p,2n) 123 I and 122 Te(d,n) 123 I reactions. These production methods are critically reviewed. Bromine-75-labeled benzodiazenes have been prepared for in vivo mapping of benzodiazepine receptor sites. The 7-( 75 Br)-5-(2-fluorophenyl)-1-methyl-1,3-dihydro-2H-1,4-benzodiazepine-2-one (BFB) was prepared with a specific activity of > 10 4 Ci/mmole. Finally, preparation and applications of the halogenated amino acid L-3-( 123 I)-iodo-α-methyltyrosine (IMT) and the analogous 75 Br compound (BMT) are reported. Both IMT and BMT have been successfully applied for pancreas imaging and tomography, and IMT has been used for imaging both melanotic and amelanotic malignant melanoma of the eye

  20. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R. [Oak Ridge National Lab., TN (United States); Kropp, J.; Biersack, H.J. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Goodman, M.M. [University of Tennessee Medical Center, Knoxville, TN (United States). Dept. of Radiology; Franken, P. [Free Univ. Hospital, Brussels (Belgium). Nuclear Medicine Dept.; Reske, S.N. [Ulm Univ. (Germany). Sektion Nuklearmedizin; Som, P. [Brookhaven National Lab., Upton, NY (United States); Sloof, G.W.; Visser, F.C. [Free Univ. Hospital, Amsterdam (Netherlands). Cardiology Dept.

    1993-06-01

    Continued Interest in the use of iodine-1 23-labeled fatty acids for myocardial Imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-I 23-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability markers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 1 5-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT).

  1. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R. (Oak Ridge National Lab., TN (United States)); Kropp, J.; Biersack, H.J. (Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin); Goodman, M.M. (University of Tennessee Medical Center, Knoxville, TN (United States). Dept. of Radiology); Franken, P. (Free Univ. Hospital, Brussels (Belgium). Nuclear Medicine Dept.); Reske, S.N. (Ulm Univ. (Germany

    1993-01-01

    Continued Interest in the use of iodine-1 23-labeled fatty acids for myocardial Imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-I 23-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability markers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 1 5-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT).

  2. Biodistribution and dosimetry of iodine-123-labelled Z-MIVE: an oestrogen receptor radioligand for breast cancer imaging

    NARCIS (Netherlands)

    Rijks, L. J.; Busemann Sokole, E.; Stabin, M. G.; de Bruin, K.; Janssen, A. G.; van Royen, E. A.

    1998-01-01

    This study reports on the distribution and radiation dosimetry of iodine-123-labelled cis-11beta-methoxy-17alpha-iodovinyloestradiol (Z-[123I]MIVE), a promising radioligand for imaging of oestrogen receptors (ERs) in human breast cancer. Whole-body scans were performed up to 24 h after intravenous

  3. Imaging of estrogen receptors in primary and metastatic breast cancer patients with iodine-123-labeled Z-MIVE

    NARCIS (Netherlands)

    Rijks, L. J.; Bakker, P. J.; van Tienhoven, G.; Noorduyn, L. A.; Boer, G. J.; Rietbroek, R. C.; Taat, C. W.; Janssen, A. G.; Veenhof, C. H.; van Royen, E. A.

    1997-01-01

    PURPOSE: To evaluate the feasibility of noninvasive imaging of estrogen receptors (ERs) in primary and metastatic breast cancer with the iodine-123-labeled ER-specific ligand cis-11beta-methoxy-17alpha-iodovinylestradiol-17beta (Z-[123I]MIVE) using conventional nuclear medicine techniques. PATIENTS

  4. Technical meeting of project counterparts on 'Cyclotron production of Iodine-123'. Report

    International Nuclear Information System (INIS)

    2002-01-01

    Several cyclotron laboratory facilities are very much interested in the production of Iodine-123 for medical applications in view of its optimal physical and chemical properties. Some of these countries have in the past used the solid target technology based on utilization of enriched Tellurium targets and are currently involved in the development of enriched Xenon-124 gas targets to improved radionuclidic purity as required by the needs of modern nuclear medicine. With the purpose of discussing the advances in the later route of production and to foster mutual co-operation among the developing countries interested in this technology, a meeting was convened with the participation of scientists from Argentina, Brazil, Iran, Korea and Syria. A scientist from the United States was also invited as an expert to provide advise on particular aspects of the technology. This publication contains as an annex technical reports from the participating institutions. All of these reports have been separately indexed and provided with abstracts

  5. Iodine-123-iodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism

    International Nuclear Information System (INIS)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Cardaci, G.; Davis, S.; Dikic, B.; Laing, B.; Mastaaglia, F.L.; O''Brein, J.

    1998-01-01

    Full text: Idiopathic Parkinson''s disease (IPD) is characterised by a loss of dopaminergic neurons in the substantia nigra. Other neurodegenerative disorders may mimic IPD, and the clinical distinction is important in patient management. Iodine-123-iodobenzamide (IBZM) has high specific binding to dopamine-2 (D2) receptors enabling SPECT studies of these receptors in the human brain. A significant reduction of D2 receptor binding of 123 I-lBZM has been shown in the basal ganglia of patients with Parkinsonian syndromes (PS) but normal uptake is seen in patients with IPD. Iodine-123-lBZM SPECT imaging has been proposed as a means of distinguishing between patients with IPD and PS and may be of value in predicting the long-term responsiveness to dopaminergic drugs. Magnetic resonance imaging has also been used to distinguish IPD from PS, and apomorphine testing is in use as a clinical means of predicting response to dopaminergic drugs. We plan to evaluate the sensitivity and specificity of 123 I-lBZM SPECT, MRI and apomorphine testing for categorisation of patients and the prediction of responsiveness to dopaminergic drugs. To date we have studied 17 patients. SPECT imaging of the brain was carried out two hours after the i.v. administration of 185 MBq of 123 I-lBZM and visual and semi-quantitative analysis, using ratios of uptake in basal ganglia to frontal cortex, occipital cortex and cerebellum have been carried out. Although the data are incomplete, preliminary results suggest that there is a poor correlation of 123 I-lBZM uptake with the provisional clinical diagnosis and with apomorphine testing, but that 123 I-lBZM uptake is a predictor of dopaminergic response

  6. Assessment of cardiac sympathetic nerve activity in children with chronic heart failure using quantitative iodine-123 metaiodobenzylguanidine imaging

    International Nuclear Information System (INIS)

    Karasawa, Kensuke; Ayusawa, Mamoru; Noto, Nobutaka; Sumitomo, Naokata; Okada, Tomoo; Harada, Kensuke

    2000-01-01

    Cardiac sympathetic nerve activity in children with chronic heart failure was examined by quantitative iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging in 33 patients aged 7.5±6.1 years (range 0-18 years), including 8 with cardiomyopathy, 15 with congenital heart disease, 3 with anthracycrine cardiotoxicity, 3 with myocarditis, 3 with primary pulmonary hypertension and 1 with Pompe's disease. Anterior planar images were obtained 15 min and 3 hr after the injection of iodine-123 MIBG. The cardiac iodine-123 MIBG uptake was assessed as the heart to upper mediastinum uptake activity ratio of the delayed image (H/M) and the cardiac percentage washout rate (%WR). The severity of chronic heart failure was class I (no medication) in 8 patients, class II (no symptom with medication) in 9, class III (symptom even with medication) in 10 and class IV (late cardiac death) in 6. H/M was 2.33±0.22 in chronic heart failure class I, 2.50±0.34 in class II, 1.95±0.61 in class III, and 1.39±0.29 in class IV (p<0.05). %WR was 24.8±12.8% in chronic heart failure class I, 23.3±10.2% in class II, 49.2±24.5% in class III, and 66.3±26.5% in class IV (p<0.05). The low H/M and high %WR were proportionate to the severity of chronic heart failure. Cardiac iodine-123 MIBG showed cardiac adrenergic neuronal dysfunction in children with severe chronic heart failure. Quantitative iodine-123 MIBG myocardial imaging is clinically useful as a predictor of therapeutic outcome and mortality in children with chronic heart failure. (author)

  7. Quantification of Iodine-123-FP-CIT SPECT with a resolution-independent method

    International Nuclear Information System (INIS)

    Dobbeleir, A.A.; Ham, H.R.; Hambye, A.E.; Vervaet, A.M.

    2005-01-01

    Accurate quantification of small-sized objects by SPECT is hampered by the partial volume effect. The present work evaluates the magnitude of this phenomenon with Iodine- 123 in phantom studies, and presents a resolution- independent method to quantify striatal I-123 FP-CIT uptake in patients. At first five syringes with internal diameters varying between 9 and 29mm and an anthropomorphic striatal phantom were filled with known concentrations of Iodine-123 and imaged by SPECT using different collimators and radii of rotation. Data were processed with and without scatter correction. From the measured activities, calibration factors were calculated for each specific collimator. Then a resolution-independent method for FP-CIT quantification using large regions of interest was developed and validated in 34 human studies (controls and patients) acquired in 2 different hospitals, by comparing its results to those obtained by a semi- quantitative striatal-to-occipital analysis. Taking the injected activity and decay into account, the measured counts/volume could be converted into absolute tracer concentrations. For the fan-beam, high resolution and medium energy collimators, the measured maximum activity in comparison to the 29 mm-diameter syringe was respectively 38%, 16% and 9% for the 9 mm-diameter syringe and 82%, 80% and 30% for the 16 mm syringe, and not significantly modified after scatter correction. For the anthropomorphic phantom, the error in measurement in % of the true concentration ranged between 0.3-9.5% and was collimator dependent. Medium energy collimators yielded the most homogeneous results. In the human studies, inter- observer variability was 11.4% for the striatal-to-occipital ratio and 3.1% for the resolution-independent method, with correlation coefficients >0.8 between both. The resolution- independent method was 89%-sensitive and 100%-specific to separate the patients without and with abnormal FP-CIT uptake (accuracy: 94%). Also the

  8. Influence of drugs on myocardial iodine-123 metaiodobenzylguanidine uptake in rabbit myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, S.; Karanikas, G.; Rodrigues, M.; Sinzinger, H. [Dept. of Nuclear Medicine, University of Vienna (Austria)

    2000-03-01

    About 15 years ago, iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging was introduced for the evaluation of myocardial sympathetic nerve function. Two uptake mechanisms for MIBG have so far been identified: uptake type I, a saturable, energy-dependent mechanism, and uptake type II, a non-saturable, energy-independent mechanism. We incubated isolated rabbit myocardial tissue samples with{sup 123}I-MIBG in order to assess the uptake characteristics and the influence of varying incubation conditions. Furthermore, we examined the effects of several drugs and uptake inhibitors on the myocardial uptake of MIBG. The in vitro myocardial uptake of MIBG reached a steady plateau at 23.87%{+-}3.63% after 1 h, i.e. a concentration gradient of 10, in a thermo-independent manner within a concentration range from 1.5 to 1500 {mu}M. This indicates an unsaturable uptake process in the tested concentrations. Pre-incubation with the following drugs caused a significant inhibitory effect on myocardial MIBG uptake: haloperidol, levomepromazine, metoprolol, labetalol and clomipramine. According to our findings, the uptake mechanism seems to be an unspecific process, but the concentration gradient of 10 makes passive diffusion unlikely. Further studies with uptake-II-blocking substances as well as with isolated myocardial cells will be needed to clarify the nature of the myocardial MIBG uptake mechanism. (orig.)

  9. Iodine-123 iodobenzofuran (I-123 IBF) SPECT in patients with parkinsonism

    International Nuclear Information System (INIS)

    Nakabeppu, Yoshiaki; Nakajo, Masayuki; Mitsuda, Mitsuru; Tsuchimochi, Shinsaku; Tani, Atsushi; Osame, Mitsuhiro

    1999-01-01

    Iodine-123 benzofuran (I-123 IBF) is a dopaminergic antagonist which is suitable for SPECT imaging of D2 receptors. The purpose of this study is to evaluate the potential usefulness of semi-quantitative parameters obtained from brain SPECT data of I-123 IBF for differential diagnosis in patients with parkinsonism (PN). Subjects were 10 patients with PN: 2 patients with striato-nigral degeneration (SND), 5 patients with Parkinson's disease (PD), 2 patients with progressive supranuclear palsy (PSP) and one patient with olivo-ponto-cerebellar atrophy (OPCA). The data were acquired with a triple-head gamma camera at 2 hours after intravenous injection of 167 MBq of I-123 IBF. Transverse images were reconstructed by means of filtered backprojection, and attenuation correction was performed by Chang's method (μ=0.08). The basal ganglia-to-frontal cortex ratio (GFR) and the basal ganglia-to-occipital cortex ratio (GOR) on slices of 5 different thicknesses were calculated. The GFR and GOR were lower in the SND group than in the other disease groups in all slices with different thicknesses (7.2 mm, 14.4 mm, 21.6 mm, 28.8 mm and 43.2 mm). The semiquantitative parameters (GFR and GOR) obtained from brain SPECT data at 2 hours after intravenous injection of I-123 IBF may be useful for differential diagnosis in patients with PN. (author)

  10. Suppression by perchlorate of technetium-99m and iodine-123 secretion in milk of lactating goats

    International Nuclear Information System (INIS)

    Mountford, P.J.; Heap, R.B.; Hamon, M.; Fleet, I.R.; Coakley, A.J.

    1987-01-01

    Lactating goats were infused with either technetium-99m (/sup 99m/Tc) or iodine-123 ( 123 I) together with chlorine-36 ( 36 Cl) through an indwelling catheter previously placed in an external pudic mammary artery. The radioisotope infusions were repeated together with 100 mg of sodium perchlorate. There was a rapid transfer of /sup 99m/Tc and 123 I into milk, reaching a peak concentration 30 min after a 15-min infusion. The fractional secretion of /sup 99m/Tc and 123 I in milk was reduced by 70%-80% and 60%-66%, respectively, by perchlorate. The fractional secretion of 36 Cl was not affected by perchlorate, and the shape of the 36 Cl secretion curve differed from those of /sup 99m/Tc and 123 I, which were similar. It is probable, therefore, that the latter nuclides were secreted by a transport route different from that of chloride. Available data describing the secretion of /sup 99m/Tc in human milk after pertechnetate administration was reviewed, and it was concluded that perchlorate pretreatment significantly reduced the secretion of /sup 99m/Tc in human breast milk

  11. Iodine-123 iodobenzofuran (I-123 IBF) SPECT in patients with parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Nakabeppu, Yoshiaki; Nakajo, Masayuki; Mitsuda, Mitsuru; Tsuchimochi, Shinsaku; Tani, Atsushi; Osame, Mitsuhiro [Kagoshima Univ. (Japan). Faculty of Medicine

    1999-12-01

    Iodine-123 benzofuran (I-123 IBF) is a dopaminergic antagonist which is suitable for SPECT imaging of D2 receptors. The purpose of this study is to evaluate the potential usefulness of semi-quantitative parameters obtained from brain SPECT data of I-123 IBF for differential diagnosis in patients with parkinsonism (PN). Subjects were 10 patients with PN: 2 patients with striato-nigral degeneration (SND), 5 patients with Parkinson's disease (PD), 2 patients with progressive supranuclear palsy (PSP) and one patient with olivo-ponto-cerebellar atrophy (OPCA). The data were acquired with a triple-head gamma camera at 2 hours after intravenous injection of 167 MBq of I-123 IBF. Transverse images were reconstructed by means of filtered backprojection, and attenuation correction was performed by Chang's method ({mu}=0.08). The basal ganglia-to-frontal cortex ratio (GFR) and the basal ganglia-to-occipital cortex ratio (GOR) on slices of 5 different thicknesses were calculated. The GFR and GOR were lower in the SND group than in the other disease groups in all slices with different thicknesses (7.2 mm, 14.4 mm, 21.6 mm, 28.8 mm and 43.2 mm). The semiquantitative parameters (GFR and GOR) obtained from brain SPECT data at 2 hours after intravenous injection of I-123 IBF may be useful for differential diagnosis in patients with PN. (author)

  12. Myocardial adrenergic nerve activity in valvular diseases assessed by iodine-123-metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Imamura, Yoshihiro; Fukuyama, Takaya

    1997-01-01

    Iodine-123-metaiodobenzylguanidine (MIBG) imaging was used to assess myocardial adrenergic nerve activity in patients with heart failure. MIBG planar images were obtained in 94 patients. The uptake of MIBG, calculated as the heart-to-mediastinum activity ratio in the immediate image (15 min), showed a significant decrease only in patients with severe heart failure due to cardiomyopathy, but was not changed in those with valvular diseases. Storage and release of MIBG, calculated as the percentage myocardial MIBG washout from 15 min to 4 hours after isotope injection, was substantially accelerated in both patients with cardiomyopathy and valvular diseases in proportion to the severity of heart failure. These data suggest that, in severe heart failure associated with cardiomyopathy, norepinephrine uptake is reduced. Also, myocardial adrenergic nerve activity is accelerated in proportion to the severity of heart failure independent of the underlying cause. MIBG images were analyzed in 20 patients with mitral stenosis with the same methods to clarify whether myocardial adrenergic nerve activity is different in patients with heart failure without left ventricular volume or pressure overload. Myocardial uptake of MIBG did not show any significant difference. The percentage myocardial MIBG washout was increased in patients with severe heart failure. The closest correlation was between myocardial washout and cardiac output. In heart failure due to mitral stenosis, myocardial adrenergic nerve activity is intensified. Decrease in cardiac output associated with mitral stenosis acts as a potent stimulus for this intensification. (author)

  13. Iodine-123 metaiodobenzylguanidine scintigraphy and iodine-123 ioflupane single photon emission computed tomography in Lewy body diseases: complementary or alternative techniques?

    Science.gov (United States)

    Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio

    2014-01-01

    To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.

  14. Iodine-123 metaiodobenzylguanidine in the assessment of late cardiac effects from cancer therapy

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Bokkel Huinink, W.W. ten; Dewit, L.G.H.; Hoefnagel, C.A.; Liem, I.H.; Tinteren, H. van

    1996-01-01

    Recognition of adverse late cardiac effects from cancer therapy may enable identification of patients with risk of cardiotoxicity upon cancer retreatment. In this study the feasibility of using iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) heart scintigraphy to detect abnormalities of the myocardial adrenergic neurone function in the late period after cancer therapy was evaluated in relation to the left ventricle ejection fraction (LVEF) in 18 cancer patients: 11 had undergone thoracic irradiation involving the heart, in five cases in combination with anthracycline therapy, 11-228 months (median 60 months) before radionuclide tests, while seven had not received previous anthracycline and/or radiotherapy (controls). The 123 I-MIBG cardiac uptake, expressed as a heart-to-mediastinum ratio on planar images after 4 h, ranged from 1.21 to 1.76 (median 1.56) in cancer therapy patients, which was significantly decreased (P=0.0006) in comparison with controls (range 1.81-2.06, median 1.9). The myocardial 123 I-MIBG washout, calculated from planar images after 15 min and 4 h, and LVEF also showed significant differences, but with some overlap in individual cases. In cancer therapy patients, cardiac abnormalities seen on planar images and additional single-photon emission tomographic images varied from focal defects to diffusely reduced myocardial uptake. It is concluded that 123 I-MIBG heart scintigraphy, which is able to identify cardiac adrenergic neurone abnormalities in the follow-up period after cancer therapy, may help to identify relapsed patients who are at increased risk of developing cardiotoxicity during retreatment with cardiotoxic therapy modalities. (orig.). With 4 figs., 2 tabs

  15. Cardiac iodine-123 metaiodobenzylguanidine uptake in animals with diabetes mellitus and/or hypertension

    International Nuclear Information System (INIS)

    Dubois, E.A.; Kam, K.L.; Somsen, G.A.; Boer, G.J.; Bruin, K. de; Batink, H.D.; Pfaffendorf, M.; Royen, E.A. van; Zwieten, P.A. van

    1996-01-01

    The aim of the present study was to evaluate the use of the noradrenaline analogue iodine-123 metaiodobenzylguanidine ([ 123 I]MIBG) for the assessment of cardiac sympathetic activity in the presence of diabetes mellitus and/or hypertension in animal models. One model used Wistar-Kyoto rats (WKY) and spontaneously hypertensive rats (SHR) rendered diabetic at 12 weeks of age by an intravenous injection of streptozotocin (STZ). The other model used lean and obese Zucker rats. In all groups basic haemodynamic values were established and animals received an intravenous injection of 50 μCi [ 123 I]MIBG. Initial myocardial uptake and washout rates of [ 123 I]MIBG were measured scintigraphically during 4 h. After sacrifice, plasma noradrenaline and left cardiac ventricular β-adrenoceptor density was determined. The diabetic state, both in STZ-treated rats (direct induction) and in obese Zucker rats (genetic induction), appeared to induce a lower cardiac density of β-adrenoceptors, indicative of increased sympathetic activity. Cardiac [ 123 I]MIBG then showed increased washouts, thereby confirming enhanced noradrenergic activity. This parallism of results led to the conclusion that [ 123 I]MIBG wash-out measurements could provide an excellent tool to assess cardiac sympathetic activity noninvasively. However, in hypertension (WKY vs SHR), both parameters failed to show parallelism: no changes in β-adrenoceptor density were found, whereas [ 123 I]MIBG wash-out rate was increased. Thus, either [ 123 I]MIBG washout or β-adrenoceptor density may not be a reliable parameter under all circumstances to detect changes in the release of noradrenaline. (orig./MG)

  16. A Family with Von Hippel-Lindau Syndrome: The Findings of Indium-111 Somatostatin Receptor Scintigraphy, Iodine-123 Metaiodobenzylguanidine Scintigraphy and Single Photon Emission Computerized Tomography

    Directory of Open Access Journals (Sweden)

    Pelin Arıcan

    2017-02-01

    Full Text Available Von Hippel-Lindau syndrome (VHLS is an autosomal dominant hereditary familial disorder characterized by development of malignant and benign neoplasms. Differential diagnosis of the adrenal and pancreatic masses are difficult in patients with VHLS. Iodine-123 metaiodobenzylguanidine (I-123 MIBG and indium-111 somatostatin receptor scintigraphies (In-111 SRS have important roles in the differential diagnosis of adrenal and pancreatic masses in those patients. In this case report, we present the findings of I-123 MIBG single-photon emission computerized tomography (SPECT/CT and In-111 SRS SPECT/CT in three members of a family with VHLS. In case 1, a residual neuroendocrine tumor (NET was detected in the head of pancreas on In-111 SRS SPECT/CT images. In case 2 and 3, I-123 MIBG SPECT/CT confirmed the adrenal masses as pheochromocytoma, and the extra-adrenal mass as NET, before surgery. We thought that In-111 SRS and I-123 MIBG scan might be helpful in the routine work up of VHLS patients for diagnostic and therapeutic purposes. Hybrid SPECT/CT system may improve diagnostic accuracy of planar images since it assesses morphologic and functional information together.

  17. Preparation of iodine-123 labeled AM251: a potential SPECT radioligand for the brain cannabinoid CB1 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Ruoxi; Makriyannis, Alexandros [Connecticut Univ., Molecular and Cell Biology Dept., Storrs, CT (United States); Gatley, S.J. [Brookhaven National Lab., Medical Dept., Upton, NY (United States)

    1996-10-01

    We report the synthesis and labeling with iodine-123 of N-(piperidin-1-yl)-5-(4-iodophenyl)-1-(2, 4-dichlorophenyl)-4-methyl-1H-pyrazole-3-carboxamide (AM251). This compound is an analog of the recently described cannabinoid receptor antagonist, SR141716A, in which a 4-chlorophenyl group is replaced by 4-iodophenyl. Labeling in good yield (62%) and radiochemical purity (> 95%), and high specific activity (> 2500 Ci/mmol) was achieved by an iododestannylation reaction using the tributyltin precursor, no carrier added I-123 iodide, and chloramine-T. (author).

  18. Reduced cortical distribution volume of iodine-123 iomazenil in Alzheimer's disease as a measure of loss of synapses

    DEFF Research Database (Denmark)

    Soricelli, A; Postiglione, A; Grivet-Fojaja, M R

    1996-01-01

    indiscriminately to affect all cortical neurons, albeit more so in some areas than in others. In this pilot study we measured Vd in six patients with probable AD and in five age-matched controls using a brain-dedicated single-photon emission tomography scanner allowing all cortical levels to be sampled......Iodine-123 labelled iomazenil (IMZ) is a specific tracer for the GABAA receptor, the dominant inhibitory synapse of the brain. The cerebral distribution volume (Vd) of IMZ may be taken as a quantitative measure of these synapses in Alzheimer's disease (AD), where synaptic loss tends...

  19. Estrogen receptor status in primary breast cancer: iodine 123-labeled cis-11beta-methoxy-17alpha-iodovinyl estradiol scintigraphy

    NARCIS (Netherlands)

    Bennink, R. J.; Rijks, L. J.; van Tienhoven, G.; Noorduyn, L. A.; Janssen, A. G.; Sloof, G. W.

    2001-01-01

    PURPOSE: To determine the sensitivity of iodine 123 ((123)I)-labeled cis-11beta-methoxy-17alpha-iodovinyl estradiol (Z-MIVE) scintigraphy for the detection of estrogen receptors in patients with primary breast carcinoma. MATERIALS AND METHODS: In 22 patients, estrogen receptor status was assessed

  20. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    International Nuclear Information System (INIS)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio

    1998-01-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of 123 I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of 123 I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). 123 I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of 123 I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the 123 I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  1. Uterine uptake of iodine-123 metaiodobenzylguanidine during the menstrual phase of uterine cycle

    International Nuclear Information System (INIS)

    Bomanji, J.; Britton, K.E.

    1987-01-01

    Radioiodinated I-123 metaiodobenzylguanidine (MIBG) has been used for diagnostic purposes for detection of apudomas. In this paper normal physiological uptake of I-123 MIBG by the uterus during the menstrual phase of the uterine cycle is reported. It is likely that I-123 MIBG can be used to evaluate some of the problems in this context

  2. Uterine uptake of iodine-123 metaiodobenzylguanidine during the menstrual phase of uterine cycle

    Energy Technology Data Exchange (ETDEWEB)

    Bomanji, J.; Britton, K.E.

    1987-08-01

    Radioiodinated I-123 metaiodobenzylguanidine (MIBG) has been used for diagnostic purposes for detection of apudomas. In this paper normal physiological uptake of I-123 MIBG by the uterus during the menstrual phase of the uterine cycle is reported. It is likely that I-123 MIBG can be used to evaluate some of the problems in this context.

  3. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Booij, J. [Graduate School of Neurosciences, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Korn, P. [Graduate School of Neurosciences, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Linszen, D.H. [Department of Psychiatry, Academic Medical Center, Tafelbergweg 25, 1105 BC Amsterdam (Netherlands); Royen, E.A. van [Graduate School of Neurosciences, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    1997-06-10

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET) and constant infusion of iodine-123 iodobenzamide ([{sup 123}I]IBZM), a D{sub 2}receptor radioligand that is sensitive to endogenous DA release. Methylphenidate induced displacement of striatal [ {sup 123}I]IBZM binding, resulting in a significantly decrease in the specific to non-specific [ {sup 123}I]IBZM uptake ratio (average: 8.6%) in comparison with placebo (average: -1.9%). Moreover, injection of methylphenidate induced significant behavioural responses on the following items: excitement, anxiety, tension, and mannerisms and posturing. The results of this study demonstrate the feasibility of using constant infusion of [ {sup 123}I]IBZM and SPET imaging to measure endogenous DA release after methylphenidate challenge and to investigate neurochemical aspects of behaviour. (orig.). With 2 figs., 1 tab.

  4. Pharmacokinetics and dosimetry of iodine-123 labelled PE2I in humans, a radioligand for dopamine transporter imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T.; Bergstroem, K.A.; Yu, Meixiang; Laitinen, T. [Department of Clinical Physiology, Kuopio University Hospital, FIN-70210 Kuopio (Finland); Baulieu, J.L.; Emond, P.; Chalon, S.; Guilloteau, D. [Laboratoire de Biophysique Medicale et Pharmaceutique, Universite Francois Rabelais, F-37200 Tours (France); Hiltunen, J.; Nikula, T. [MAP Medical Technologies Oy, FIN-41160 Tikkakoski (Finland); Halldin, C.; Farde, L. [Karolinska Institute, Department of Clinical Neuroscience, Psychiatry Section, Karolinska Hospital, S-17 176 Stockholm (Sweden); Karhu, J. [Department of Clinical Neurophysiology, Kuopio University Hospital, FIN-70210 Kuopio (Finland); Tupala, E.; Hallikainen, T.; Tiihonen, J. [Department of Forensic Psychiatry, Niuvanniemi Hospital, FIN-70240 Kuopio (Finland); Kolehmainen, V. [Department of Applied Physics, University of Kuopio, FIN-70210 Kuopio (Finland); Mauclaire, L. [CIS bio international, F-91192 Gif-sur-Yvette (France); Maziere, B. [Service Hospitalier Frederic Joliot, CEA, F-91406 Orsay (France)

    1998-05-01

    The iodine-123 labelled selective ligand N-(3-iodoprop-2E-enyl)-2-{beta}-carbomethoxy-3{beta}-(4-methylphenyl)nortropane ([{sup 123}I]PE2I) was evaluated as a probe for in vivo dopamine transporter imaging in the human brain. Six healthy subjects were imaged with a high-resolution single-photon emission tomography scanner. Striatal radioactivity peaked at 1 h after injection. The background radioactivity was low. The volume of distribution in the striatum was 94{+-}24 ml/ml. The results were compared with those of [{sup 123}I]{beta}-CIT imaging. There was no significant uptake of [{sup 123}I]PE2I in serotonin-rich regions such as the midbrain, hypothalamus and anterior gingulus, suggesting that in vivo binding is specific for the dopamine transporter. One main polar metabolite of [{sup 123}I]PE2I was found in plasma, and the parent plasma concentration decayed rapidly. Radiation exposure to the study subject is 0.022{+-}0.004 mSv/MBq (effective dose). The preliminary results suggest that [{sup 123}I]PE2I is a selective SPET ligand for imaging striatal dopamine transporter density. (orig.) With 4 figs., 11 refs.

  5. Pharmacokinetics and dosimetry of iodine-123 labelled PE2I in humans, a radioligand for dopamine transporter imaging

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Yu, Meixiang; Laitinen, T.; Baulieu, J.L.; Emond, P.; Chalon, S.; Guilloteau, D.; Hiltunen, J.; Nikula, T.; Halldin, C.; Farde, L.; Karhu, J.; Tupala, E.; Hallikainen, T.; Tiihonen, J.; Kolehmainen, V.; Mauclaire, L.; Maziere, B.

    1998-01-01

    The iodine-123 labelled selective ligand N-(3-iodoprop-2E-enyl)-2-β-carbomethoxy-3β-(4-methylphenyl)nortropane ([ 123 I]PE2I) was evaluated as a probe for in vivo dopamine transporter imaging in the human brain. Six healthy subjects were imaged with a high-resolution single-photon emission tomography scanner. Striatal radioactivity peaked at 1 h after injection. The background radioactivity was low. The volume of distribution in the striatum was 94±24 ml/ml. The results were compared with those of [ 123 I]β-CIT imaging. There was no significant uptake of [ 123 I]PE2I in serotonin-rich regions such as the midbrain, hypothalamus and anterior gingulus, suggesting that in vivo binding is specific for the dopamine transporter. One main polar metabolite of [ 123 I]PE2I was found in plasma, and the parent plasma concentration decayed rapidly. Radiation exposure to the study subject is 0.022±0.004 mSv/MBq (effective dose). The preliminary results suggest that [ 123 I]PE2I is a selective SPET ligand for imaging striatal dopamine transporter density. (orig.)

  6. Iodine-123-metaiodobenzylguanidine cardiac scintigraphy in patients with diabetes mellitus. Therapeutic effects of aldose reductase inhibitor and vitamin B12

    International Nuclear Information System (INIS)

    Utsunomiya, Keita

    1997-01-01

    Twenty normal volunteers (C group) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM) who did not have ischemic heart diseases (DM group), were evaluated by means of iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy. The uptake ratio between the cardiac muscle and the upper mediastinum was calculated. The ratio determined from the initial I-123-MIBG scintigraphy image was expressed as HMi, and that determined from the delayed image was expressed as HMd. The washout rate percentage (%WR) was calculated. At least one instance of either the HMi, the HMd, or %WR was outside the mean±1 standard deviation of C group in 34 DM group patients. Aldose reductase inhibitor (ARI) was administered to 17 of the 34 patients and Vitamin B 12 (VB 12 ) to the remaining 17 patients, for 3 to 5 months. Before and after treatment, scintigraphic studies with I-123-MIBG were carried out, and the HMi, HMd, and %WR were calculated. There were no significant differences found in FBG, HbA1c, or 1.5-AG levels after treatment with either drug, when compared to the pretreatment values. Both HMi and HMd in the DM group were significantly lower, and %WR was significantly higher than in the C group. The changes in HMi, HMd, and %WR after treatment with ARI were not significant. After treatment with VB 12 , the HMi and HMd levels were significantly increased (p 12 was shown to be effective for improvement of HMi and HMd in NIDDM. (author)

  7. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    International Nuclear Information System (INIS)

    Booij, J.; Korn, P.; Linszen, D.H.; Royen, E.A. van

    1997-01-01

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET) and constant infusion of iodine-123 iodobenzamide ([ 123 I[IBZM), a D 2 receptor radioligand that is sensitive to endogenous DA release. Methylphenidate induced displacement of striatal [ 123 I[IBZM binding, resulting in a significantly decrease in the specific to non-specific [ 123 I[IBZM uptake ratio (average: 8.6%) in comparison with placebo (average: -1.9%). Moreover, injection of methylphenidate induced significant behavioural responses on the following items: excitement, anxiety, tension, and mannerisms and posturing. The results of this study demonstrate the feasibility of using constant infusion of [ 123 I[IBZM and SPET imaging to measure endogenous DA release after methylphenidate challenge and to investigate neurochemical aspects of behaviour. (orig.). With 2 figs., 1 tab

  8. Research and clinical applications of iodine-123 fibrinogen in coagulation disorders

    International Nuclear Information System (INIS)

    DeNardo, G.L.; DeNardo, S.J.; Swanson, M.A.; Wortman, J.A.; Twardock, A.R.; Colcher, D.

    1985-01-01

    A great many proteins are available to serve as molecular substrates suitable for investigation of normal and diseased states. These proteins, labeled with the appropriate radioisotope of iodine, can be used for immunoassays, imaging, and systemic radiotherapy. The authors describe 12 years experience using coagulation proteins for the investigation of cancer, venous thrombosis, renal transplant rejection, and other coagulopathies. Scintigraphy with 123 I-fibrinogen and immunoassays for circulating antigens such as fibrinopeptide A appear to be promising diagnostic, as well as investigative, tools

  9. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  10. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D{sub 2}receptor images in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Acton, P.D. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Pilowsky, L.S. [Institute of Psychiatry, London (United Kingdom); Costa, D.C. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Ell, P.J. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom)

    1997-02-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D{sub 2}receptor concentrations measured by iodine-123 iodobenzamide ({sup 123}I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D {sub 2}receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand {sup 123}I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D {sub 2}receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D {sub 2}receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D {sub 2}asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs.

  11. Biodistribution and dosimetry of (iodine-123)-iodomethyl-N,N-diethyltamoxifen, an (anti)oestrogen receptor radioligand

    International Nuclear Information System (INIS)

    Wiele, C. van de; Sutter, J. de; Dierckx, R.A.; Vos, F. de; Dumont, F.; Slegers, G.; Thierens, H.

    1999-01-01

    This study reports on the distribution and radiation dosimetry of iodine-123 labelled trans-Z-iodomethyl-N,N-diethyltamoxifen (123-ITX), a promising radioligand for prediction of the therapeutic efficacy of unlabelled tamoxifen in human breast carcinoma. Whole-body scans were performed up to 24 h after intravenous injection of 123-ITX (mean: 146 MBq, range: 142-148 MBq) in five female volunteers, four with and one without thyroid blockade. Blood samples were taken at various times up to 24 h after injection. Urine was also collected up to 24 h after injection, allowing calculation of renal clearance and interpretation of whole-body clearance. Time-activity curves were generated for the thyroid, heart, brain, breasts, liver and gallbladder by fitting the organ-specific geometric mean counts, obtained from regions of interest. The MIRD formulation was applied to calculate the absorbed radiation doses for various organs. The images showed rapid hepatobiliary excretion, resulting in good imaging conditions for the thoracic region, whereas imaging of the abdominal region was impeded by extensive bowel activity. The breast to non-specific uptake ratio increased over time. 123-ITX was cleared by both the kidneys and the gastrointestinal tract. At 50 h p.i. the mean excretion in the urine was 89.4% (SD 5.7%). If the thyroid was not blocked, it was one of the critical organs. The highest absorbed doses were received by the excretory organs, i.e. the urinary bladder wall, the lower and upper large intestine, and the gallbladder wall. The average effective dose of 123-ITX was estimated to be 0.0084 mSv/MBq. The amount of 123-ITX required for adequate imaging of tumoral uptake results in an acceptable effective dose to the patient. (orig.)

  12. Disease stage classification in hypertrophic cardiomyopathy by dual analysis of iodine-123-labeled metaiodobenzylguanidine and thallium-201 myocardial scintigraphies

    Energy Technology Data Exchange (ETDEWEB)

    Hiasa, Go [Ehime Univ., Matsuyama (Japan). School of Medicine

    2001-08-01

    Many patients with hypertrophic cardiomyopathy (HCM) gradually changes from typical myocardial hypertrophy to dilated cardiomyopathy-like features. However, it is difficult to estimate the disease stage in HCM. To determine the disease stage, dual analysis of iodine-123-labeled metaiodobenzylguanidine ({sup 123}I-MIBG) and thallium-201 ({sup 201}Tl) myocardial scintigraphies were performed in 108 HCM patients. According to the scintigraphic distribution patterns, patients were divided into three groups. Group A (n=15): normal distributions of both {sup 123}I-MIBG and {sup 201}Tl, group B (n=71): normal {sup 201}Tl and low {sup 123}I-MIBG patterns, group C (n=22): low distributions of both scintigraphies. The decrease in {sup 201}Tl uptake was observed in only group C. Concerning {sup 123}I-MIBG, heart-to-mediastinum ratio (H/M) and washout rate (WOR) had good correlations with left ventricular systolic functions. H/M was decreased and WOR was increased in order of C, B and A groups. Left ventricular diastolic function reflected by isovolumic relaxation time was longer in group B than in group A. Attenuated left ventricular hypertrophy, enlarged left ventricular volumes, impaired left ventricular functions and serious clinical symptoms were observed in only group C. Myocardial sympathetic abnormalities in group B may be mainly due to myocardial hypertrophy, and those in group C may be due to myocardial injury. Dual analysis of {sup 123}I-MIBG and {sup 201}Tl scintigraphies may be useful to classify disease stages of HCM. (author)

  13. Prognostic significance of myocardial imaging with iodine-123 beta-methyl-p-iodophenyl-pentadecanoic acid in patients with angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Tsuguhisa; Chikamori, Taishiro; Kamada, Tatsuya; Morishima, Takayuki; Hida, Satoshi; Yanagisawa, Hidefumi; Iino, Hitoshi; Yamashina, Akira [Tokyo Medical Coll. (Japan)

    2001-09-01

    To assess the clinical significance of iodine-123 beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT), the predictive value of BMIPP imaging in patients with angina pectoris was evaluated. One hundred seventy-four patients who underwent BMIPP imaging in our institution were aged 61.8{+-}11 years. One hundred thirty-five patients had stable angina and 39 had unstable angina at the time of examination. Patients with previous myocardial infarction or myocardial disorders were excluded. Early and delayed images were acquired in BMIPP SPECT, and the images were analyzed visually. Cardiac events were classified into hard and soft events: the former consisted of cardiac death and nonfatal myocardial infarction, and the latter included coronary revascularization and heart failure. The findings of BMIPP imaging were normal in 82 patients and abnormal in 92. During follow-up of 15.5{+-}9.5 months, hard events were observed in 4 patients and soft events in 53. In patients with normal BMIPP imaging, soft events were observed in nine patients, but no hard event was encountered. Furthermore, in patients with both normal BMIPP and stress thallium imagings, no cardiac event was observed during 2 years. In contrast, 4 hard events and 44 soft events occurred in patients with abnormal BMIPP imaging. Patients with abnormal BMIPP imaging had a higher incidence of soft events than those with normal BMIPP imaging, regardless of the type of angina (16/62 vs 3/73, p<0.0005 for stable angina; 28/30 vs 6/9, p<0.0001 for unstable angina). The finding of BMIPP imaging correlates well with the mid-term prognosis of patients with angina pectoris. Since BMIPP SPECT is performed without stress to the patient, this imaging modality is important in evaluating patients with stable or unstable angina. (author)

  14. A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Itoh, Hiroshi; Bloomfield, P.M.; Munaka, Masahiro; Higano, Shuichi; Murakami, Matsutaro; Inugami, Atsushi; Eberl, S.; Aizawa, Yasuo; Kanno, Iwao; Uemura, Kazuo

    1994-01-01

    A method has been developed to quantitate regional cerebral blood blow (rCBF) using iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two single-photon emission tomography (SPET) scans and one blood sample. Based on a two-compartment model, radioactivity concentrations in the brain for each scan time are calculated. A standard input function has been generated by combining the input functions from 12 independent studies prior to this work to avoid frequent arterial blood sampling, and one blood sample is taken at 10 min following IMP administration for calibration of the standard arterial input function. This calibration time was determined such that the integration of the first 40 min of the calibrated, combined input function agreed best with those from 12 individual input functions (the difference was 5.3% on average). This method was applied to eight subjects (two normals and six patients with cerebral infarction), and yielded rCBF values which agreed well with those obtained by a positron emission tomography H 2 15 O autoradiography method. This method was also found to provide rCBF values that were consistent with those obtained by the non-linear least squares fitting technique and those obtained by conventional microsphere model analysis. The optimum SPET scan times were found to be 40 and 180 min for the early and delayed scans, respectively. These scan times allow the use of a conventional rotating gamma camera for clinical purposes. V d values ranged between 10 and 40 ml/g depending on the pathological condition, thereby suggesting the importance of measuring V d for each ROI. In conclusion, optimization of the blood sampling time and the scanning time enabled quantitative measurement of rCBF with two SPET scans and one blood sample. (orig.)

  15. Imaging active lymphocytic infiltration in coeliac disease with iodine-123-interleukin-2 and the response to diet

    International Nuclear Information System (INIS)

    Signore, A.; Chianelli, M.; Annovazzi, A.; Rossi, M.; Greco, M.; Ronga, G.; Picarelli, A.; Maiuri, L.; Britton, K.E.

    2000-01-01

    Coeliac disease is diagnosed by the presence of specific antibodies and a jejunal biopsy showing mucosal atrophy and mononuclear cell infiltration. Mucosal cell-mediated immune response is considered the central event in the pathogenesis of coeliac disease, and untreated coeliac patients show specific features of T-cell activation in the small intestine. Here we describe the use of iodine-123-interleukin-2 scintigraphy in coeliac patients as a non-invasive tool for detection of lymphocytic infiltration in the small bowel and its use for therapy follow-up, and we demonstrate the specificity of binding of labelled-IL2 to activated lymphocytes by ex-vivo autoradiography of jejunal biopsies. 123 I-IL2 was administered i.v. [74 MBq (2 mCi)], and gamma camera images were acquired after 1 h. Ten patients were studied with 123 I-IL2 scintigraphy at diagnosis and seven were also investigated after 12-19 months of gluten-free diet. Results were expressed as target-to-background radioactivity ratios in six different bowel regions before and after the diet. At the time of diagnosis all patients showed a significantly higher bowel uptake of 123 I-IL2 than normal subjects (P 2 =0.66; P=0.008). Autoradiography of jejunal biopsies confirmed that labelled-IL2 only binds to activated T-lymphocytes infiltrating the gut mucosa. After 1 year of the diet, bowel uptake of 123 I-IL2 significantly decreased in five out of six regions (P 123 I-IL2 scintigraphy is a sensitive non-invasive technique for assessing in vivo the presence of activated mononuclear cells in the bowel of patients affected by coeliac disease. Unlike jejunal biopsy, this method provides information from the whole intestine and gives a non-invasive measure of the effectiveness of the gluten-free diet. (orig.)

  16. Dosimetry estimation of SPECT/CT for iodine 123-labeled metaiodobenzylguanidine in children

    Directory of Open Access Journals (Sweden)

    Aida Mhiri

    2015-09-01

    Full Text Available Purpose: To evaluate the additional radiation exposure in terms of effective dose incurred by patients in the CT (computed tomography portion of 123I-MIBG (123II-metaiodobenzylguanidine study with SPECT/CT (Single photon emission computed tomography associated to computed tomography in some pediatric patients of our department. Methods: Data from 123II-MIBG scans comprising 50 children were presented in this study. The contribution of total effective dose imparted by the nuclear tracer and patient's age was calculated. Effective dose from the CT portion of the examination is also estimated.SPECT acquisitions were performed with a dual-headed SPECT unit with an integrated 2-slice CT scanner (Symbia T E-Cam, Siemens Medical Systems, Erlangen, Germany. The CT acquisition were performed using a tube current modulation system (Care Dose 4D. Parameters used were: tube current of 30 - 60 mAs, slice thickness of 3-5 mm, and tube voltage of 110 kV. Results: Our results show that SPECT dosimetry depends on administered activity and patient’s age and weight. For CT scan, effective dose is affected by tube current (mA, tube potential (kVp, rotation speed, pitch, slice thickness, patient mass, and the exact volume of the patient that is being imaged. Conclusion: For children, 123II-MIBG study with SPECT/CT should be performed using the lowest available voltage and current. A sensible choice of these two parameters used can significantly reduce radiation dose, without any compromise in the quality of the diagnostic information.

  17. Imaging active lymphocytic infiltration in coeliac disease with iodine-123-interleukin-2 and the response to diet

    Energy Technology Data Exchange (ETDEWEB)

    Signore, A.; Chianelli, M.; Annovazzi, A.; Rossi, M.; Greco, M.; Ronga, G.; Picarelli, A. [Nuclear Medicine Unit (Nu.M.E.D. Group) and Gastroenterology Unit, Department of Clinical Sciences, University of Rome ' ' La Sapienza' ' (Italy); Maiuri, L. [Inst. of Paediatrics, Children' s Hospital Posilipon, University ' ' Federico II' ' , Naples (Italy); Britton, K.E. [Dept. of Nuclear Medicine, St. Bartholomew' s Hospital, London (United Kingdom)

    2000-01-01

    Coeliac disease is diagnosed by the presence of specific antibodies and a jejunal biopsy showing mucosal atrophy and mononuclear cell infiltration. Mucosal cell-mediated immune response is considered the central event in the pathogenesis of coeliac disease, and untreated coeliac patients show specific features of T-cell activation in the small intestine. Here we describe the use of iodine-123-interleukin-2 scintigraphy in coeliac patients as a non-invasive tool for detection of lymphocytic infiltration in the small bowel and its use for therapy follow-up, and we demonstrate the specificity of binding of labelled-IL2 to activated lymphocytes by ex-vivo autoradiography of jejunal biopsies. {sup 123}I-IL2 was administered i.v. [74 MBq (2 mCi)], and gamma camera images were acquired after 1 h. Ten patients were studied with {sup 123}I-IL2 scintigraphy at diagnosis and seven were also investigated after 12-19 months of gluten-free diet. Results were expressed as target-to-background radioactivity ratios in six different bowel regions before and after the diet. At the time of diagnosis all patients showed a significantly higher bowel uptake of {sup 123}I-IL2 than normal subjects (P<0.003 in all regions). A significant correlation was found between jejunal radioactivity and the number of IL2R+ve lymphocytes per millimetre of jejunal mucosa as detected by immunostaining of jejunal biopsy (r{sup 2}=0.66; P=0.008). Autoradiography of jejunal biopsies confirmed that labelled-IL2 only binds to activated T-lymphocytes infiltrating the gut mucosa. After 1 year of the diet, bowel uptake of {sup 123}I-IL2 significantly decreased in five out of six regions (P<0.03), although two patients still had a positive IL2 scintigraphy in one region. We conclude that {sup 123}I-IL2 scintigraphy is a sensitive non-invasive technique for assessing in vivo the presence of activated mononuclear cells in the bowel of patients affected by coeliac disease. Unlike jejunal biopsy, this method provides

  18. The diagnostic usefulness of the negative electroretinogram.

    Science.gov (United States)

    Fuente García, C; González-López, J J; Muñoz-Negrete, F J; Rebolleda, G

    2018-03-01

    The definition of the negative response of the full field electroretinogram is the presence of a b-wave with less amplitude than the a-wave (b/a ratio<1) in the combined response of cones and rods. The presence of this pattern reflects an alteration in the bipolar cells, the Müller cells, or in the transmission of the stimulus from the photoreceptors to the bipolar cells, with preserved photoreceptor function. This finding can be seen bilaterally and symmetrically in different hereditary conditions, such as congenital stationary night blindness, juvenile X-linked retinoschisis, and Duchenne and Becker muscular dystrophies. On the other hand, it can also be found unilaterally (or asymmetrically) in acquired pathologies, such as some types of immuno-mediated retinitis (Birdshot retinochoroiditis), autoimmune retinopathies, cancer/melanoma associated retinopathy, or retinal toxicity. The objective of this review is to summarise the characteristics of the pathologies in which this finding can be observed, in order to highlight its usefulness in the differential diagnosis of retinal conditions. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Evaluation of a diagnostic algorithm for smear-negative pulmonary ...

    African Journals Online (AJOL)

    Evaluation of a diagnostic algorithm for smear-negative pulmonary tuberculosis in HIV-infected adults. ... Subjects. Subjects included 58 HIV-infected adult patients with suspected PTB consecutively referred to the local TB clinic for outpatient TB treatment using this algorithm between 12 February 2004 and 30 April 2005.

  20. Reconstruction of negative hydrogen ion beam properties from beamline diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ruf, Benjamin

    2014-09-25

    For the experimental fusion reactor ITER, which should show the feasibility of sustaining a fusion plasma with a positive power balance, some technology still has to be developed, amongst others also the plasma heating system. One heating technique is the neutral beam injection (NBI). A beam of fast deuterium atoms is injected into the fusion plasma. By heavy particle collisions the beam particles give their energy to the plasma. A NBI system consists of three major components. First, deuterium ions are generated in a low temperature, low pressure plasma of an ion source. At ITER, the requirements on the beam energy of 1 MeV cause the necessity of negative charged deuterium ions. Secondly, the ions are accelerated within an acceleration system with several grids, where the plasma grid is the first grid. The grids are on different descending high voltage potentials. The source itself is on the highest negative potential. Thirdly, the fast deuterium ions have to be neutralised. This thesis deals with the second step in the mentioned beam system, the ion acceleration and beam formation. The underlying experiments and measurements were carried out at the testbeds BATMAN (BAvarianTest MAchine for Negative ions) and ELISE (Extraction from a Large Ion Source Experiment) at the Max-Planck-Institut fuer Plasmaphysik Garching (IPP Garching). The main goal of this thesis is to provide a tool which allows the determination of the beam properties. These are beam divergence, stripping losses and beam inhomogeneity. For this purpose a particle trajectory code has been developed from scratch, namely BBC-NI (Bavarian Beam Code for Negative Ions). The code is able to simulate the whole beam and the outcome of several beam diagnostic tools. The data obtained from the code together with the measurements of the beam diagnostic tools should allow the reconstruction of the beam properties. The major beam diagnostic tool, which is used in this thesis, is the beam emission spectroscopy

  1. Alternating myocardial sympathetic neural function of athlete's heart in professional cycle racers examined with iodine-123-MIBG myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Keiko; Inoue, Tomio; Hasegawa, Akira; Oriuchi, Noboru; Okamoto, Eiichi; Tomaru, Yumi; Endo, Keigo [Gunma Univ., Maebashi (Japan). School of Medicine

    2001-08-01

    Myocardial sympathetic neural function in professional athletes who had the long-term tremendous cardiac load has not been fully investigated by myocardial iodine-123-metaiodobenzylguanidine (MIBG) uptake in comparison with power spectral analysis (PSA) in electrocardiography. Eleven male professional cycle racers and age-matched 11 male healthy volunteers were enrolled in this study. The low frequency components in the power spectral density (LF), the high frequency components in the power spectral density (HF), the LF/HF ratio and mean R-R interval were derived from PSA and time-domain analysis of heart rate variability in electrocardiography. The mean heart-to-mediastinum uptake ratio (H/M ratio) of the MIBG uptake, in professional cycle racers was significantly lower than that in healthy volunteers (p<0.01) and HF power in professional cycle racers was significantly higher than that in healthy volunteers (p<0.05). In the group of professional cycle racers, the H/M ratio showed a significant correlation with the R-R interval, as indices of parasympathetic nerve activity (r=0.80, p<0.01), but not with the LF/HF ratio as an index of sympathetic nerve activity. These results may indicate that parasympathetic nerve activity has an effect on MIBG uptake in a cyclist's heart. (author)

  2. Myocardial rest iodine-123-{beta}-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    Energy Technology Data Exchange (ETDEWEB)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro [Kumamoto City Hospital (Japan)

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-{beta}-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3{+-}5.6) was higher than that on delayed thallium scintigraphy (2.9{+-}2.7) and it was almost the same as on the initial dipyridamole stress test (6.5{+-}5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  3. Scintigraphic differentiation between two forms of primary dysautonomia early after onset of autonomic dysfunction: value of cardiac and pulmonary iodine-123 MIBG uptake

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, M.J.; Juengling, F.D.; Krause, T.M. [Dept. of Nuclear Medicine, Freiburg University Hospital (Germany); Braune, S. [Dept. of Neurology, Freiburg University Hospital (Germany)

    2000-05-01

    Primary dysfunction of the autonomic nervous system can be observed in patients with Parkinson's disease and those with multiple system atrophy. However, the fate of the two diseases differs considerably and leads to different strategies for patient management. Differentiation of the two diseases currently requires a combination of several clinical and electrophysiological tests. First studies of myocardial innervation using iodine-123 metaiodobenzylguanidine (MIBG) indicated a possible role of scintigraphy for this purpose. An increase in the pulmonary uptake of {sup 123}I-MIBG has been reported in secondary dysautonomias. Whether sympathetic innervation of the lung is affected in primary dysautonomias is currently unknown. Therefore, cardiac and pulmonary uptake of {sup 123}I-MIBG was studied in 21 patients with Parkinson's disease, 7 patients with multiple system atrophy and 13 age- and sex-matched controls. Thoracic images were obtained in the anterior view 4 h after intravenous injection of 185 MBq {sup 123}I-MIBG, at which time the maximum neuronal uptake is reached. All patients with Parkinson's disease had significantly lower cardiac uptake of {sup 123}I-MIBG than patients with multiple system atrophy and controls. Sympathetic innervation of the lung was not affected in either disease. It is concluded that scintigraphy with {sup 123}I-MIBG appears to be a useful tool for differentiation between Parkinson's disease and multiple system atrophy early after onset of autonomic dysfunction. (orig.)

  4. Iodine-123 phenylpentadecanoic acid: detection of acute myocardial infarction and injury in dogs using an iodinated fatty acid and single-photon emission tomography

    International Nuclear Information System (INIS)

    Rellas, J.S.; Corbett, J.R.; Kulkarni, P.

    1983-01-01

    The ability of an iodinated fatty acid, iodine-123 phenylpentadecanoic acid (1-123 PPA), and single-photon emission computed tomography (SPECT) to detect myocardium injured by temporary or permanent coronary arterial occlusion was evaluated. In 5 control dogs, 11 dogs that underwent 90 to 120 minutes of fixed left anterior descending coronary artery (LAD) occlusion, and 8 dogs that underwent 90 minutes of temporary LAD occlusion and up to 90 minutes of reflow, 2 to 6 mCi of I-123 PPA were injected and the dogs were imaged with SPECT. Control dogs showed relatively uniform uptake and clearance of I-123 PPA in similar left ventricular (LV) regions. Dogs with permanent LAD occlusion were identified by computer algorithm as having regions of decreased I-123 PPA uptake in the infarct-related area and a reduced rate of I-123 PPA clearance (-9.4% in infarct sectors [washin], +3.7% in sectors adjacent to the area of infarction, and +15.4% in control LV sectors [p less than 0.01]). Dogs with temporary LAD occlusion and reperfusion had decreased clearance of I-123 PPA from the regions with infarction; I-123 PPA clearance was -5.2 +/- 16.4% in infarct sectors, 12.7 +/- 7.4% in periinfarct zones, and 30.4 +/- 12% in control LV regions. These data demonstrate that tomographic analysis of I-123 PPA uptake and clearance permits the relatively noninvasive detection of LV myocardium injured by permanent or temporary LAD occlusion and reperfusion

  5. Investigation of the relationship between regression of hypertensive cardiac hypertrophy and improvement of cardiac sympathetic nervous dysfunction using iodine-123 metaiodobenzylguanidine myocardial imaging

    International Nuclear Information System (INIS)

    Morimoto, Satoshi; Terada, Koji; Keira, Natsuya; Satoda, Masahiko; Inoue, Keiji; Tatsukawa, Hirotaka; Katoh, Shuji; Ida, Kazunori; Sugihara, Hiroki; Takeda, Kazuo; Nakagawa, Masao

    1996-01-01

    Although many theories exist on the subject, the mechanisms responsible for a reduction of hypertensive cardiac hypertrophy in response to antihypertensive therapy are still unclear. In order to investigate the relationship between regression of hypertensive cardiac hypertrophy and cardiac nervous function, we studied ten patients with untreated essential hypertension (six men and four women, 62±12 years old). Both echocardiography and iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging were performed before and after antihypertensive therapy. Left ventricular mass (LVM) was significantly reduced in conjunction with the reduction of blood pressure following treatment. MIBG myocardial images showed that the heart-to-mediastinum activity ratio (H/M) was significantly increased while the washout ratio was significantly decreased. Patients were divided into two groups according to the ratio of the LVM values before and after therapy (LVM ratio). Patients with an LVM ratio of less than 0.75 were classified as group A and those with values higher than 0.75 as group B. Neither the change in blood pressure nor the length of treatment was significantly different between these two groups. On the other hand, both the increase in H/M and the decrease in the washout ratio were significantly greater in group A than in group B. These results indicate that an improvement in cardiac sympathetic nervous function may be related to the regression of hypertensive cardiac hypertrophy. Increasing the subject base in these studies and a more precise analysis of the relevance of the data obtained from MIBG myocardial images are recommended to clarify how changes in cardiac sympathetic nervous function relate to the regression of hypertensive cardiac hypertrophy. (orig.)

  6. Significance of retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid myocardial scintigraphy in patients with vasospastic angina

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Fumitaka; Hashimoto, Toshio; Uemura, Shiro; Kawamoto, Atsuhiko; Dohi, Kazuhiro [Nara Medical Univ., Kashihara (Japan); Matsushima, Akihiko

    2001-07-01

    This study investigated retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) scintigraphy in patients with vasospastic angina. Twenty-three patients with vasospastic angina showed abnormal uptake of BMIPP before medical treatment and had coronary vasospasm induced by acetylcholine. The patients were divided into two groups according to uptake of BMIPP after medical treatment: retardation of abnormal uptake of BMIPP (Group R, n=4) and normal uptake of BMIPP (Group N, n=19). Frequency of chest pain, medical treatment and autonomic nervous activity were compared between the two groups. Furthermore, the frequency of chest pain and uptake of BMIPP in group R were obtained after intensive medical treatment. Autonomic nervous activity was evaluated by heart rate variability on Holter electrocardiography. Heart rate variability contained high-frequency elements (HF; 0.15-0.4 Hz) and low-frequency elements (LF; 0.04-0.15 Hz). LF/HF was estimated for sympathetic nervous activity and HF was estimated for parasympathetic nervous activity. Daytime and nighttime autonomic nervous activity were compared between the two groups. The frequency of chest pain was higher in Group R than in Group N (p<0.05). Medical treatment was not different between the two groups. Circadian variation of sympathetic and parasympathetic nervous activity were absent in Group R. During the nighttime, Group R showed higher sympathetic nervous activity (p<0.05) and lower parasympathetic nervous activity (p<0.01) than Group N. The frequency of chest pain was significantly lower after intensive medical treatment (p<0.05), and uptake of BMIPP returned to normal in Group R. We suspected that the disorder in autonomic nervous activity was more severe in Group R, and thus induced coronary vasospasm. Retardation of abnormal uptake of BMIPP in patients with vasospastic angina indicates poor control of coronary vasospasm. Uptake of BMIPP is useful in the evaluation of

  7. Fatty acid metabolic and perfusion abnormalities in hypertrophied myocardium assessed by dual tracer tomography using thallium-201 and iodine-123-beta-methylpentadecanoic acid

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hiroshi; Nakata, Tomoaki; Han, Shizui (Sapporo Medical Coll. (Japan)) (and others)

    Fatty acid and perfusion abnormalities associated with cardiac hypertrophy were investigated using dual tracer tomography with thallium and a cardiac metabolic tracer, 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP), in eight patients with hypertrophic cardiomyopathy (HCM) and in three with hypertension (HT). Thallium and BMIPP uptakes were scored and analyzed in 143 segments (13/heart) by comparison with the left ventricular wall thickness measured by two dimensional echocardiography. Complete agreement of both scores in HT patients was significantly higher than that in HCM patients (64% vs 24%, p<0.001), while a lower BMIPP uptake compared to that of thallium (mismatching) was observed more frequently in HCM than in HT patients (65% vs 31%, p<0.001). The wall thickness significantly (p<0.005) correlated with BMIPP uptake score. HCM patients showed a low BMIPP uptake in 22 hypertrophic segments (59%) and 15 non-hypertrophic segments (41%), and reduced BMIPP uptake in 29% hypertrophic segments, while HT patients showed just five segments with decreased BMIPP uptake of which 4 were non-hypertrophic and only one hypertrophic. The left ventricular ejection fraction assessed by radionuclide ventriculography was normal and no regional wall motion abnormality was detected in any patient by echocardiographic and scintigraphic studies. Metabolic abnormalities detected by the iodine-123-beta-methyl fatty acid analog in hypertrophic cardiomyopathy may be independent of thallium myocardial perfusion, regional wall motion, or the magnitude of cardiac hypertrophy, suggesting that fatty acid imaging may be useful in investigating the pathogenesis and subclinical abnormality of hypertrophic cardiomyopathy, and differentiation from secondary, induced cardiac hypertrophy. (author).

  8. Decrease in benzodiazepine receptor binding in a patient with Angelman syndrome detected by iodine-123 iomazenil and single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Anezaki, Toshiharu [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan); Ohkubo, Masaki [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Yonekura, Yoshiharu [Nihon Medi-Physics Co. Ltd., Hyogo (Japan); Onishi, Yoshihiro [Biomedical Imaging Research Center, Fukui Medical School, Fukui (Japan); Inuzuka, Takashi [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan); Takahashi, Makoto [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Tsuji, Shoji [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan)

    1996-05-01

    A receptor mapping technique using iodine-123 iomazenil and single-photon emission tomography (SPET) was employed to examine benzodiazepine receptor binding in a patient with Angelman syndrome (AS). AS is characterized by developmental delay, seizures, inappropriate laughter and ataxic movement. In this entity there is a cytogenic deletion of the proximal long arm of chromosome 15q11-q13, where the gene encoding the GABA{sub A} receptor {beta}3 subunit (GABRB3) is located. Since the benzodiazepine receptor is constructed as a receptor-ionophore complex that contains the GABA{sub A} receptor, it is a suitable marker for GABA-ergic synapsis. To determine whether benzodiazepine receptor density, which indirectly indicates changes in GABA{sub A} receptor density, is altered in the brain in patients with AS, we investigated a 27-year-old woman with AS using {sup 123}I-iomazenil and SPET. Receptor density was quantitatively assessed by measuring the binding potential using a simplified method. Regional cerebral blood flow was also measured with N-isopropyl-p-[{sup 123}]iodoamphetamine. We demonstrated that benzodiazepine receptor density is severely decreased in the cerebellum, and mildly decreased in the frontal and temporal cortices and basal ganglia, a result which is considered to indicate decreased GABA{sub A} receptor density in these regions. Although the deletion of GABRB3 was not observed in the present study, we indirectly demonstrated the disturbance of inhibitory neurotransmission mediated by the GABA{sub A} receptor in the investigated patient. {sup 123}I-iomazenil with SPET was useful to map benzodiazepine receptors, which indicate GABA{sub A} receptor distribution and their density. (orig.)

  9. Effects of aldose reductase inhibitor and vitamin B12 on myocardial uptake of iodine-123 metaiodobenzylguanidine in patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Utsunomiya, Keita; Narabayashi, Isamu; Tamura, Koji; Nakatani, Yuko; Saika, Yoshinori; Onishi, Satoshi; Kariyone, Shigeo

    1998-01-01

    This study was undertaken to examine the effects of aldose reductase inhibitor (ARI) and vitamin B 12 (VB12) on myocardial uptake of iodine-123 metaiodobenzylguanidine (MIBG) in patients with diabetic autonomic disorder. Myocardial scintigraphy using 123 I-MIBG was performed on 20 healthy volunteers (controls) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM), in order to obtain the heart/mediastinum ratio in the initial (HMi) and the delayed images (HMd), and the washout rate (%WR). Thirty-four of the 56 NIDDM patients could be diagnosed as having diabetic autonomic disorder by evaluating their scintigraphic findings in comparison with the controls. Seventeen of these 34 patients received 150 mg/day of epalrestat (ARI group) in three divided doses before meals, and the other 17 received 1.5 mg/day of mecobalamin (VB12 group) in three divided doses after meals, for 3-5 months. According to the presence or absence of clinical symptoms of autonomic or peripheral somatic nerve disorder, the patients were subclassified into four groups. group 1=patients, with autonomic symptoms or somatosensory disorder in the ARI group; group 2=patients without autonomic symptoms or somatosensory disorder in the ARI group; group 3=patients with autonomic symptoms or somatosensory disorder in the VB12 group; and group 4=patients without autonomic symptoms or somatosensory disorder in the VB12 group. After completion of the treatment, myocardial scintigraphy was performed again. Comparing the results obtained before and after the treatment, it was seen that ARI improved only the HMi in group 1 (P=0.046), whereas VB12 significantly improved HMi in the group 3 (P=0.018) and HMi, HMd and %WR in group 4 (P=0.043, P=0.018 and P=0.043, respectively). We conclude that VB12 is more efficacious than ARI in the treatment of diabetic cardiovascular autonomic disorder. (orig.)

  10. Demonstration of disturbed free fatty acid metabolism of myocardium in patients with non-insulin-dependent diabetes mellitus as measured with iodine-123-heptadecanoic acid

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Mustonen, J.N.; Uusitupa, M.I.J.; Rautio, P.; Vanninen, E.; Laakso, M.; Laensimies, E.; Kuopio Central Hospital

    1991-01-01

    Myocardial free fatty acid metabolism and left ventricular function were evaluated in 15 middle-aged patients with non-insulin dependent diabetes mellitus (NIDDM) and in 8 healthy control subjects. The study subjects had no evidence of coronary heart disease on the basis of clinical history, exercise ECG or myocardial perfusion scintigraphy. During peak exercise, iodine-123 hepatadecanoic acid (HDA) was intravenously injected. Myocardial activity distribution of 123 I-HDA was measured 10, 30, and 50 min after exercise using single-photon emission tomography (SPET); and then further corrected by free 123 I-iodine. Venous blood samples were drawn for detecting the plasma activity of 123 I. The net extraction of 123 I-HDA into the myocardium was obtained by dividing the corrected tissue 123 I concentration by the integral of the plasma time activity curve. The net extraction was 0.40±0.06 min -1 (mean±SD) patients with NIDDM and 0.38±0.006 min -1 in control subjects (P>0.1), respectively. The faster elimination rate of 123 I-HDA was found in patients with NIDDM (0.029±0.008 min -1 ) than in control subjects (0.022±0.004 min - 1); P 123 I-HDA and the change of LVEF, as well as with exercise load (r=0.68; P<0.01). In conclusion, evidence of an increased fatty acid utilization and triglyceride synthesis rate was observed in the diabetic myocardium. (orig.)

  11. Significance of retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Inoue, Fumitaka; Hashimoto, Toshio; Uemura, Shiro; Kawamoto, Atsuhiko; Dohi, Kazuhiro; Matsushima, Akihiko

    2001-01-01

    This study investigated retardation of abnormal uptake of iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) scintigraphy in patients with vasospastic angina. Twenty-three patients with vasospastic angina showed abnormal uptake of BMIPP before medical treatment and had coronary vasospasm induced by acetylcholine. The patients were divided into two groups according to uptake of BMIPP after medical treatment: retardation of abnormal uptake of BMIPP (Group R, n=4) and normal uptake of BMIPP (Group N, n=19). Frequency of chest pain, medical treatment and autonomic nervous activity were compared between the two groups. Furthermore, the frequency of chest pain and uptake of BMIPP in group R were obtained after intensive medical treatment. Autonomic nervous activity was evaluated by heart rate variability on Holter electrocardiography. Heart rate variability contained high-frequency elements (HF; 0.15-0.4 Hz) and low-frequency elements (LF; 0.04-0.15 Hz). LF/HF was estimated for sympathetic nervous activity and HF was estimated for parasympathetic nervous activity. Daytime and nighttime autonomic nervous activity were compared between the two groups. The frequency of chest pain was higher in Group R than in Group N (p<0.05). Medical treatment was not different between the two groups. Circadian variation of sympathetic and parasympathetic nervous activity were absent in Group R. During the nighttime, Group R showed higher sympathetic nervous activity (p<0.05) and lower parasympathetic nervous activity (p<0.01) than Group N. The frequency of chest pain was significantly lower after intensive medical treatment (p<0.05), and uptake of BMIPP returned to normal in Group R. We suspected that the disorder in autonomic nervous activity was more severe in Group R, and thus induced coronary vasospasm. Retardation of abnormal uptake of BMIPP in patients with vasospastic angina indicates poor control of coronary vasospasm. Uptake of BMIPP is useful in the evaluation of

  12. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-123I IMP single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi

    2001-01-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V d ) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ( 123 I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the 123 I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p d was also significantly decreased in the pons (p d for the pons and age at onset (r=0.59, p d in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p d obtained by 123 I-IMP SPECT for patients with MJD identified by gene analysis. Our study shows that SPECT measurement of rCBF and V d is useful for understanding the pathophysiology of MJD. (author)

  13. Neutralisation and transport of negative ion beams: physics and diagnostics

    Science.gov (United States)

    Serianni, G.; Agostinetti, P.; Agostini, M.; Antoni, V.; Aprile, D.; Baltador, C.; Barbisan, M.; Brombin, M.; Cavenago, M.; Chitarin, G.; Dalla Palma, M.; Delogu, R.; Fellin, F.; Fonnesu, N.; Marconato, N.; Pasqualotto, R.; Pimazzoni, A.; Sartori, E.; Spagnolo, S.; Spolaore, M.; Veltri, P.; Zaniol, B.; Zaupa, M.

    2017-04-01

    Neutral beam injection is one of the most important methods of plasma heating in thermonuclear fusion experiments, allowing the attainment of fusion conditions as well as driving the plasma current. Neutral beams are generally produced by electrostatically accelerating ions, which are neutralised before injection into the magnetised plasma. At the particle energy required for the most advanced thermonuclear devices and particularly for ITER, neutralisation of positive ions is very inefficient so that negative ions are used. The present paper is devoted to the description of the phenomena occurring when a high-power multi-ampere negative ion beam travels from the beam source towards the plasma. Simulation of the trajectory of the beam and of its features requires various numerical codes, which must take into account all relevant phenomena. The leitmotiv is represented by the interaction of the beam with the background gas. The main outcome is the partial neutralisation of the beam particles, but ionisation of the background gas also occurs, with several physical and technological consequences. Diagnostic methods capable of investigating the beam properties and of assessing the relevance of the various phenomena will be discussed. Examples will be given regarding the measurements collected in the small flexible NIO1 source and regarding the expected results of the prototype of the neutral beam injectors for ITER. The tight connection between measurements and simulations in view of the operation of the beam is highlighted.

  14. Demonstration of disturbed free fatty acid metabolism of myocardium in patients with non-insulin-dependent diabetes mellitus as measured with iodine-123-heptadecanoic acid

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. (Kuopio Central Hospital (Finland). Dept. of Clinical Physiology); Mustonen, J.N.; Uusitupa, M.I.J.; Rautio, P.; Vanninen, E.; Laakso, M.; Laensimies, E. (Kuopio Central Hospital (Finland). Dept. of Medicine Kuopio Central Hospital (Finland). Dept. of Clinical Nutrition)

    1991-07-01

    Myocardial free fatty acid metabolism and left ventricular function were evaluated in 15 middle-aged patients with non-insulin dependent diabetes mellitus (NIDDM) and in 8 healthy control subjects. The study subjects had no evidence of coronary heart disease on the basis of clinical history, exercise ECG or myocardial perfusion scintigraphy. During peak exercise, iodine-123 hepatadecanoic acid (HDA) was intravenously injected. Myocardial activity distribution of {sup 123}I-HDA was measured 10, 30, and 50 min after exercise using single-photon emission tomography (SPET); and then further corrected by free {sup 123}I-iodine. Venous blood samples were drawn for detecting the plasma activity of {sup 123}I. The net extraction of {sup 123}I-HDA into the myocardium was obtained by dividing the corrected tissue {sup 123}I concentration by the integral of the plasma time activity curve. The net extraction was 0.40+-0.06 min{sup {minus}1} (mean+-SD) patients with NIDDM and 0.38+-0.006 min{sup {minus}1} in control subjects (P>0.1), respectively. The faster elimination rate of {sup 123}I-HDA was found in patients with NIDDM (0.029+-0.008 min{sup {minus}1}) than in control subjects (0.022+-0.004 min{sup {minus}1}); (P<0.01). There no statistically significant difference in left ventricular ejection fraction (LVEF) at rest between patients with NIDDM (53+-9%) and control subjects (56+-2%), whereas the increase of LVEF during exercise remained lower in patients with NIDDM (3.4+-8.2) than in control subjects (11.8+-5.8%; P<0.025). A significant correlation (r=0.64; P<0.01) was found between the net extraction of {sup 123}I-HDA and the change of LVEF, as well as with exercise load (r=0.68; P<0.01). In conclusion, evidence of an increased fatty acid utilization and triglyceride synthesis rate was observed in the diabetic myocardium. (orig.).

  15. Use of iodine-123 metaiodobenzylguanidine scintigraphy to assess cardiac sympathetic denervation and the impact of hypertension in patients with non-insulin-dependent diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Koji; Nakatani, Yuko; Onishi, Satoshi [Dept. of Internal Medicine, Keihanna Hospital, Hirakata City, Osaka (Japan); Utsunomiya, Keita; Saika, Yoshinori [Dept. of Radiology, Keihanna Hospital, Hirakata City (Japan); Iwasaka, Toshiji [Cardiovascular Center, Kansai Medical University, Osaka (Japan)

    1999-10-01

    The objectives of this clinical study using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy were (a) to evaluate cardiac sympathetic denervation in non-insulin-dependent diabetes mellitus (NIDDM) patients with and without hypertension and (b) to investigate the relation between cardiac sympathetic denervation and prognosis in NIDDM patients. We compared clinical characteristics and MIBG data [heart to mediastinum (H/M) ratio and % washout rate (WR)] in a control group and NIDDM patients with and without hypertension. MIBG scintigraphy was performed in 11 controls and 82 NIDDM patients without overt cardiovascular disease except for hypertension (systolic blood pressure {>=}140 and/or diastolic blood pressure {>=}90 mmHg). After MIBG examination, blood pressure was measured regularly in all NIDDM patients. There were significant differences between 65 normotensive and 17 hypertensive NIDDM patients with respect to age (55{+-}11 vs 63{+-}12 years, respectively, P<0.05), prevalence of diabetic retinopathy (12% vs 35%, respectively, P<0.05) and systolic blood pressure (120{+-}12 vs 145{+-}16 mmHg, respectively, P<0.001). The H/M ratio in hypertensive NIDDM patients was significantly lower than in the control group (1.81{+-}0.29 vs 2.27{+-}0.20, respectively, P<0.01). During the follow-up period (18{+-} 12 months), 17 NIDDM patients newly developed hypertension after MIBG examination. There were no significant differences in their clinical characteristics compared with persistently normotensive or hypertensive NIDDM patients. %WR in patients with new onset hypertension was significantly higher than in the control group (30.88%{+-}16.87% vs 12.89%{+-}11.94%, respectively, P<0.05). Moreover, in these patients %WR correlated with duration from the date of MIBG scintigraphy to the onset of hypertension (r=-0.512, P<0.05). Five NIDDM patients died during the follow-up period (four newly hypertensive patients and one normotensive patient). There were significant

  16. Use of iodine-123 metaiodobenzylguanidine scintigraphy to assess cardiac sympathetic denervation and the impact of hypertension in patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Tamura, Koji; Nakatani, Yuko; Onishi, Satoshi; Utsunomiya, Keita; Saika, Yoshinori; Iwasaka, Toshiji

    1999-01-01

    The objectives of this clinical study using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy were (a) to evaluate cardiac sympathetic denervation in non-insulin-dependent diabetes mellitus (NIDDM) patients with and without hypertension and (b) to investigate the relation between cardiac sympathetic denervation and prognosis in NIDDM patients. We compared clinical characteristics and MIBG data [heart to mediastinum (H/M) ratio and % washout rate (WR)] in a control group and NIDDM patients with and without hypertension. MIBG scintigraphy was performed in 11 controls and 82 NIDDM patients without overt cardiovascular disease except for hypertension (systolic blood pressure ≥140 and/or diastolic blood pressure ≥90 mmHg). After MIBG examination, blood pressure was measured regularly in all NIDDM patients. There were significant differences between 65 normotensive and 17 hypertensive NIDDM patients with respect to age (55±11 vs 63±12 years, respectively, P<0.05), prevalence of diabetic retinopathy (12% vs 35%, respectively, P<0.05) and systolic blood pressure (120±12 vs 145±16 mmHg, respectively, P<0.001). The H/M ratio in hypertensive NIDDM patients was significantly lower than in the control group (1.81±0.29 vs 2.27±0.20, respectively, P<0.01). During the follow-up period (18± 12 months), 17 NIDDM patients newly developed hypertension after MIBG examination. There were no significant differences in their clinical characteristics compared with persistently normotensive or hypertensive NIDDM patients. %WR in patients with new onset hypertension was significantly higher than in the control group (30.88%±16.87% vs 12.89%±11.94%, respectively, P<0.05). Moreover, in these patients %WR correlated with duration from the date of MIBG scintigraphy to the onset of hypertension (r=-0.512, P<0.05). Five NIDDM patients died during the follow-up period (four newly hypertensive patients and one normotensive patient). There were significant statistical differences

  17. Evaluation of negative ion distribution changes by image processing diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, K., E-mail: ikeda.katsunori@lhd.nifs.ac.jp; Nakano, H.; Tsumori, K.; Kisaki, M.; Nagaoka, K.; Tokuzawa, T.; Osakabe, M.; Takeiri, Y.; Kaneko, O. [National Institute for Fusion Science, 322-6 Oroshi Toki Gifu, 509-5292 (Japan); Geng, S. [The Graduate University for Advanced Studies, Toki Gifu, 509-5292 (Japan)

    2015-04-08

    Distributions of hydrogen Balmer-α (H{sub α}) intensity and its reduction behavior close to a plasma grid (PG) surface have been observed by a spectrally selective imaging system in an arc discharge type negative hydrogen ion source in National Institute for Fusion Science. H{sub α} reduction indicates a reduction of negative hydrogen ions because the mutual neutralization process between H{sup +} and H{sup −} ions causes the dominant excitation process for H{sub α} emission in the rich H{sup −} condition such as in ionic plasma. We observed a significant change in H{sub α} reduction distribution due to change in the bias voltage, which is used to suppress the electron influx. Small H{sub α} reduction in higher bias is likely because the production of negative ions is suppressed by the potential difference between the plasma and PG surface.

  18. Diagnostic value of glypican-3 in alpha fetoprotein negative ...

    African Journals Online (AJOL)

    Background: The prognosis of patients with hepatocellular carcinoma(HCC) is generally very poor with a 5-year survival rate of less than 15% since most of them are diagnosed clinically at their late stage.However,the differential diagnosis between alpha fetoprotein(AFP) negative HCC and cirrhotic nodules is still difficult.

  19. Iodine-123-labeled radiotracers for cardiovascular and testicular imaging studies: labeling of phenyl fatty acids for myocardial studies, fibronectin for thrombus localization, and human chorionic gonadotropin for testicular studies

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Lewis, S.E.; McConnell, J.; Buja, L.M.; Wilson, J.E. III; Willerson, J.T.; Parkey, R.W.

    1985-01-01

    Development and evaluation of iodine-123-labeled compounds for potential applications in certain imaging studies are described. A new method utilizing an organothallium intermediate has been developed to radioiodinate phenyl fatty acids. The method is simple, and consistently high yields (80 to 90%) can be obtained on a routine basis. The biodistribution patterns of the product prepared by this method were found to be very similar to those produced by the direct electrophilic substitution method. Radioiodinated fibronectin (FN) localized in experimental thrombi and pulmonary emboli. In dogs the deep-vein thrombi could be visualized within 3 hr of postinjection of the tracer. Radioiodinated human chorionic gonadotropin (HCG) localized in rat testes which permitted the scintigraphic visualization of scrotal as well as abdominal testes in rats. The localization appears to be receptor mediated

  20. [Diagnostic and therapeutic management of Gram-negative infections].

    Science.gov (United States)

    Bassetti, Matteo; Repetto, Ernestina

    2008-04-01

    Among Gram negative bacteria, Pseudomonas aeruginosa, the extended spectrum beta-lactamases (ESBL)-producing strains, Acinetobacter spp, in particular the multiresistant Acinetobacter baumannii, and Stenotrophomonas maltophilia are the most implicated micrororganisms in the ever more increasing problem of bacterial resistance. Possible solutions have to be searched, on one hand, in the use of new drugs but, on the other hand, in the re-evaluation of those already available drugs, possibly considering a new role for old drugs such as colistine and fosfomycin. Concerning ESBL-producing strains, the most recent data provided by EARSS report, in Italy, an incidence rate of 10-25 percent. The insurgence of an infection sustained by an ESBL+ve strain is strictly related to some well known risk factors, like the hospital stay itself, the disease severity, the length of stay in ICU, intubation and mechanical ventilation, catheterization, urinary or artery, and the past exposure to antibiotics. The raise in ESBL producing strains is closely related to the increasing use of cephalosporins. In the setting of a Gram negative infection, the combination therapy guarantees a higher coverage by reducing insurgence of possible resistance mechanisms, possibly resulting synergistic, and allowing a de-escalation therapy, although to this latter other problems, such as tolerability, costs and compliance, can be related. Another basic aspect to take into account of, in order to achieve the maximal efficacy of the antibiotic treatment, is the right dosage. In the idea to look for the best approach for the antibiotic treatment of a severe infection in a hospital setting, when a Gram negative aetiology is implicated, it can be possibly presumed that the right way consists in avoiding inappropriate antibiotic therapies, making therapeutic choices based on guidelines resulted from local epidemiological data, initiating the therapy promptly, avoiding excessive use of antibiotics, possibly

  1. Correlation of regional wall motion and fatty acid metabolism in coronary artery disease, hypertension, and hypertrophic cardiomyopathy; Assessment by dual-isotope SPECT with thallium-201 and iodine-123 [beta]-methyl fatty acid analogue

    Energy Technology Data Exchange (ETDEWEB)

    Hase, Mamoru; Nakata, Tomoaki; Yonekura, Shuji (Sapporo Medical Coll. (Japan)) (and others)

    1993-05-01

    In order to investigate the correlation between cardiac fatty acid metabolism and regional wall motion, dual-isotope tomography using thallium-201 and iodine-123 labeled 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP), was performed in 15 patients with coronary artery disease (CAD), hypertension, or hypertrophic cardiomyopathy (HCM). The uptake of thallium and BMIPP was scored and compared with left ventricular regional wall motion assessed by 2-dimensional echocardiography and radionuclide ventriculography. The incidence of a complete agreement of thallium and BMIPP scores was significantly higher in hypertension (64%) and CAD (63%) groups compared to HCM patients (24%), while a lower BMIPP uptake compared to that of thallium (mismatching) was observed more frequently in HCM (65%) than in hypertension (31%) or CAD (33%). Only 3 infarct patients had regional wall motion abnormality which was detected in 20 (95%) of 21 segments with a low BMIPP uptake. Furthermore, compared to thallium perfusion, decreased BMIPP uptake much more corresponded to reduced wall motion in 8 of 11 segments with mismatching. Thus, metabolic abnormality assessed by BMIPP is well associated with asynergy in CAD patients, whereas the discrepancy of fatty acid metabolism and contraction is more dominant in HCM, suggesting that the combined assessment of thallium perfusion, BMIPP uptake, and regional wall motion might contribute to better understanding of the pathogenesis of various cardiac disorders. (author).

  2. Clinical usefulness of myocardial iodine-123-15-(p-iodophenyl)-3(R,S)-methyl-pentadecanoic acid distribution abnormality in patients with mitochondrial encephalomyopathy based on normal data file in bull's-eye polar map

    International Nuclear Information System (INIS)

    Takahashi, Nobukazu; Mitani, Isao; Sumita, Shinichi

    1998-01-01

    Visual interpretation of iodine-123-beta-15-(p-iodophenyl)-3(R,S)-methyl-pentadecanoic acid ( 123 I-BMIPP) myocardial images cannot easily detect mild reduction in tracer uptake. Objective assessment of myocardial 123 I-BMIPP maldistributions at rest was attempted using a bull's-eye map and its normal data file for detecting myocardial damage in patients with mitochondrial encephalomyopathy. Six patients, two with Kearns-Sayre syndrome and four with mitochondrial myopathy, encephalopathy, lactic acidosis, and strokelike episodes (MELAS), and 10 normal subjects were studied. Fractional myocardial uptake of 1 23 I-BMIPP was also measured by dynamic static imaging to assess the global myocardial free fatty acid. These data were compared with the cardiothoracic ratio measured by chest radiography and left ventricular ejection fraction assessed by echocardiography. Abnormal cardiothoracic ratio and lower ejection fraction were detected in only one patient with Kearns-Sayre syndrome. Abnormal fractional myocardial uptake was detected in two patients (1.61%, 1.91%), whereas abnormal regional 123 I-BMIPP uptake assessed by the bull's-eye map was detected in five patients (83%). All patients showed abnormal uptake in the anterior portion, and one showed progressive atrioventricular conduction abnormality and systolic dysfunction with extended 123 I-BMIPP abnormal uptake. The results suggest that assessment based on the normal data file in a bull's-eye polar map is clinically useful for detection of myocardial damage in patients with mitochondrial encephalomyopathy. (author)

  3. Chasing down the triple-negative myeloproliferative neoplasms: Implications for molecular diagnostics.

    Science.gov (United States)

    Langabeer, Stephen E

    2016-01-01

    The majority of patients with classical myeloproliferative neoplasms (MPN) of polycythemia vera, essential thrombocythemia, and primary myelofibrosis harbor distinct disease-driving mutations within the JAK2 , CALR , or MPL genes. The term triple-negative has been recently applied to those MPN without evidence of these consistent mutations, prompting whole or targeted exome sequencing approaches to determine the driver mutational status of this subgroup. These strategies have identified numerous novel mutations that occur in alternative exons of both JAK2 and MPL , the majority of which result in functional activation. Current molecular diagnostic approaches may possess insufficient coverage to detect these alternative mutations, prompting further consideration of targeted exon sequencing into routine diagnostic practice. How to incorporate these illuminating findings into the expanding molecular diagnostic algorithm for MPN requires continual attention.

  4. Negative emotionality across diagnostic models: RDoC, DSM-5 Section III, and FFM.

    Science.gov (United States)

    Gore, Whitney L; Widiger, Thomas A

    2018-03-01

    The research domain criteria (RDoC) were established in an effort to explore underlying dimensions that cut across many existing disorders and to provide an alternative to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5). One purpose of the present study was to suggest a potential alignment of RDoC negative valence with 2 other dimensional models of negative emotionality: five-factor model (FFM) neuroticism and the DSM-5 Section III negative affectivity. A second purpose of the study, though, was to compare their coverage of negative emotionality, more specifically with respect to affective instability. Participants were adult community residents (N = 90) currently in mental health treatment. Participants received self-report measures of RDoC negative valence, FFM neuroticism, and DSM-5 Section III negative affectivity, along with measures of affective instability, borderline personality disorder, and impairment. Findings suggested that RDoC negative valence is commensurate with FFM neuroticism and DSM-5 Section III negative affectivity, and it would be beneficial if it was expanded to include affective instability. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Epidemiology of meningitis with a negative CSF Gram stain: under-utilization of available diagnostic tests.

    Science.gov (United States)

    Nesher, L; Hadi, C M; Salazar, L; Wootton, S H; Garey, K W; Lasco, T; Luce, A M; Hasbun, R

    2016-01-01

    Meningitis with a negative cerebrospinal fluid Gram stain (CSF-GS) poses a diagnostic challenge as more than 50% of patients remain without an aetiology. The introduction of polymerase chain reaction (PCR) and arboviral serologies have increased diagnostic capabilities, yet large scale epidemiological studies evaluating their use in clinical practice are lacking. We conducted a prospective observational study in New Orleans between November 1999 and September 2008 (early era) when PCR was not widely available, and in Houston between November 2008 and June 2013 (modern era), when PCR was commonly used. Patients presenting with meningitis and negative CSF-GS were followed for 4 weeks. All investigations, PCR used, and results were recorded as they became available. In 323 patients enrolled, PCR provided the highest diagnostic yield (24·2%) but was ordered for 128 (39·6%) patients; followed by serology for arboviruses (15%) that was ordered for 100 (31%) of all patients. The yield of blood cultures was (10·3%) and that of CSF cultures was 4%; the yield for all other tests was meningitis and a negative CSF-GS, but both tests are being under-utilized.

  6. Myocardial scintigraphy using iodine-123 15-(p-Iodophenyl)-3-R, S-methylpentadecanoic acid predicts the response to beta-blocker therapy in patients with dilated cardiomyopathy but does not reflect therapeutic effect

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, Keiichiro; Tahara, Minoru; Torii, Hiroyuki; Akimoto, Masaki [Kagoshima City Medical Association Hopital (Japan); Kihara, Koichi; Tei, Chuwa

    2000-05-01

    Myocardial fatty acid metabolism is disturbed in patients with idiopathic dilated cardiomyopathy. Myocardial scintigraphy using iodine-123 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP) was used to assess the response to {beta}-blocker therapy in 19 patients with dilated cardiomyopathy. BMIPP myocardial scintigraphy was performed before and 6 months after initiating {beta}-blocker therapy with metoprolol. Cardiac BMIPP uptake was assessed as the total defect score (TDS) and heart-to-mediastinum activity (H/M) ratio. Patients were classified retrospectively as responders with an improvement of at least one functional class (New York Heart Association) or an increase in ejection fraction of {>=}0.10 at 6 months, or as nonresponders meeting neither criterion. Responders had a significantly better pretreatment TDS (p<0.005) and H/M ratio (p<0.0001) than nonresponders. TDS exhibited no significant changes over 6 months in either group (responders: 13.2{+-}3.7 vs 12.5{+-}3.3; nonresponders: 20.8{+-}6.5 vs 20.5{+-}3.0). Responders showed no significant changes in H/M ratio (2.47{+-}0.28 vs 2.43{+-}0.42); paradoxically, nonresponders showed a significant increase from 1.82{+-}0.11 to 2.10{+-}0.19 (p<0.05), suggesting that {beta}-blocker therapy protected the myocardial fatty acid metabolism even in the absence of clinical improvement. BMIPP myocardial scintigraphy provides a prediction of response to {beta}-blocker treatment, but does not reflect the therapeutic effect in responders at 6 months. (author)

  7. Clinical value of lung uptake of iodine-123 metaiodobenzylguanidine (MIBG), a myocardial sympathetic nerve imaging agent, in patients with chronic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Xiuli; Hasegawa, Shinji; Yoshioka, Jun [Osaka Univ., Suita (Japan). Graduate School of Medicine] (and others)

    2001-10-01

    This study investigated the clinical value of I-123 MIBG pulmonary accumulation and washout in patients with chronic heart failure (CHF). Nineteen patients with CHF and 15 normal volunteers (NL) were included. The uptake ratio of heart to mediastinum (H/M), that of lung fields to mediastinum (L/M), and washout rate (WR) of the heart and lung fields were calculated in anterior planar images and compared with results of echocardiography and cardiac catheterization. In the CHF group, the lung uptake in delayed images increased and lung WR was decreased, suggesting pulmonary endothelial lesions. Furthermore, there was a negative correlation between right and left lung WR and pulmonary arterial diastolic pressure (PA(D)) and pulmonary arterial systolic pressure (PA(S)) in the CHF group. Since the WR of MIBG reflected PA, it may be used as an index of severity of cardiac dysfunction. (author)

  8. Therapeutic effect of co-enzyme Q10 on idiopathic dilated cardiomyopathy: assessment by iodine-123 labelled 15-(p-iodophenyl)-3(R,S)-methylpentadecanoic acid myocardial single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-ih [Department of Internal Medicine, Nishiyodo Hospital, Nishiyodo (Japan); Sawada, Yoshihiro [Department of Internal Medicine, Nishiyodo Hospital, Nishiyodo (Japan); Fujiwara, Go [Department of Radiology, Nishiyodo Hospital, Nishiyodo (Japan); Chiba, Hiroshi [Department of Internal Medicine, Mimihara General Hospital, Mimihara (Japan); Nishimura, Tsunehiko [Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Osaka (Japan)

    1997-06-10

    It has been reported that myocardial mitochondrial function can be improved by the administration of co-enzyme Q10 (CoQ10). Recently, iodine-123 labelled 15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) was developed for metabolic imaging using single-photon emission tomography (SPET). This study was conducted to determine whether the therapeutic effects of CoQ10 on idiopathic dilated cardiomyopathy can be evaluated by BMIPP myocardial SPET. Fifteen patients, comprising 14 men and one woman (mean age: 64{+-}12 years), were examined. CoQ10 was administered at 30 mg/day for a period of 35.7{+-}12.4 days. BMIPP myocardial SPET was carried out before and after CoQ10 treatment. The count ratio of the heart (H) to the upper mediastinum (M) (H/M ratio) was calculated using a region of interest method with anterior planar imaging. Representative short-axis tomograms were divided into 27 segments (three slices x nine segments). Each segmental score was analysed semiquantitatively using a four-point scoring system (normal=0, mild low uptake=1, severe low uptake=2, defect=3). The H/M ratio showed a significant improvement, from 2.39{+-}0.39 to 2.54{+-}0.47, after treatment (P<0.05). The BMIPP total defect score after CoQ10 treatment was significantly decreased to 10.1{+-}4.3, compared to 13.9{+-}4.5 without CoQ10 treatment (P<0.001). However, the percent fractional shortening measured using echocardiography was not significantly different before and after CoQ treatment (19.2{+-}8.1 vs 19.7{+-}7.1). BMIPP myocardial SPET was confirmed to be sensitive in evaluating the therapeutic effects of CoQ10 in patients with idiopathic dilated cardiomyopathy. This method is unique, since the therapeutic effects can be estimated from the perspective of metabolic SPET imaging. (orig.). With 5 figs., 1 tab.

  9. Evaluation of beam divergence of a negative hydrogen ion beam using Doppler shift spectroscopy diagnostics

    Science.gov (United States)

    Deka, A. J.; Bharathi, P.; Pandya, K.; Bandyopadhyay, M.; Bhuyan, M.; Yadav, R. K.; Tyagi, H.; Gahlaut, A.; Chakraborty, A.

    2018-01-01

    The Doppler Shift Spectroscopy (DSS) diagnostic is in the conceptual stage to estimate beam divergence, stripping losses, and beam uniformity of the 100 keV hydrogen Diagnostics Neutral Beam of International Thermonuclear Experimental Reactor. This DSS diagnostic is used to measure the above-mentioned parameters with an error of less than 10%. To aid the design calculations and to establish a methodology for estimation of the beam divergence, DSS measurements were carried out on the existing prototype ion source RF Operated Beam Source in India for Negative ion Research. Emissions of the fast-excited neutrals that are generated from the extracted negative ions were collected in the target tank, and the line broadening of these emissions were used for estimating beam divergence. The observed broadening is a convolution of broadenings due to beam divergence, collection optics, voltage ripple, beam focusing, and instrumental broadening. Hence, for estimating the beam divergence from the observed line broadening, a systematic line profile analysis was performed. To minimize the error in the divergence measurements, a study on error propagation in the beam divergence measurements was carried out and the error was estimated. The measurements of beam divergence were done at a constant RF power of 50 kW and a source pressure of 0.6 Pa by varying the extraction voltage from 4 kV to10 kV and the acceleration voltage from 10 kV to 15 kV. These measurements were then compared with the calorimetric divergence, and the results seemed to agree within 10%. A minimum beam divergence of ˜3° was obtained when the source was operated at an extraction voltage of ˜5 kV and at a ˜10 kV acceleration voltage, i.e., at a total applied voltage of 15 kV. This is in agreement with the values reported in experiments carried out on similar sources elsewhere.

  10. Diagnostic value of transient dilatation of the left ventricle in negative dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Seo, Hiromi; Doi, Y.L.; Yonezawa, Yoshihiro; Chikamori, Taishiro; Yamada, Mitsutoshi; Ozawa, Toshio

    1994-01-01

    To evaluate the diagnostic value of a transient dilatation of the left ventricle during dipyridamole-thallium imaging (DTI) for detecting significant coronary artery disease (CAD) in patients with negative DTI results, 81 consecutive patients were studied. Twenty one patients (26%) had CAD and 60 patients had normal coronary anatomy (NCA). The initial/delayed ratio of the left ventricular dimension, which was measured as the distance between the 2 peaks of a count profile curve on a 45deg left anterior oblique planar image, was defined as the dilatation ratio (DR) of the left ventricle. Patients with CAD had a higher incidence of chest pain after dipyridamole infusion (35 vs 13%; p 1.03) when it was greater than the mean +2 standard deviations of the DR in NCA patients. Seventy-six percent of CAD patients had an abnormal DR. A stepwise discriminant analysis revealed that an abnormal DR alone had the same ability to predict CAD (sensitivity 76%, specificity 98%, chi-square 80.9, p 1.03) is a highly specific marker for detecting CAD, even in patients with negative dipyridamole-thallium imaging. (author)

  11. Status of the Negative Ion Based Heating and Diagnostic Neutral Beams for ITER

    Science.gov (United States)

    Schunke, B.; Bora, D.; Hemsworth, R.; Tanga, A.

    2009-03-01

    The current baseline of ITER foresees 2 Heating Neutral Beam (HNB's) systems based on negative ion technology, each accelerating to 1 MeV 40 A of D- and capable of delivering 16.5 MW of D0 to the ITER plasma, with a 3rd HNB injector foreseen as an upgrade option [1]. In addition a dedicated Diagnostic Neutral Beam (DNB) accelerating 60 A of H- to 100 keV will inject ≈15 A equivalent of H0 for charge exchange recombination spectroscopy and other diagnostics. Recently the RF driven negative ion source developed by IPP Garching has replaced the filamented ion source as the reference ITER design. The RF source developed at IPP, which is approximately a quarter scale of the source needed for ITER, is expected to have reduced caesium consumption compared to the filamented arc driven ion source. The RF driven source has demonstrated adequate accelerated D- and H- current densities as well as long-pulse operation [2, 3]. It is foreseen that the HNB's and the DNB will use the same negative ion source. Experiments with a half ITER-size ion source are on-going at IPP and the operation of a full-scale ion source will be demonstrated, at full power and pulse length, in the dedicated Ion Source Test Bed (ISTF), which will be part of the Neutral Beam Test Facility (NBTF), in Padua, Italy. This facility will carry out the necessary R&D for the HNB's for ITER and demonstrate operation of the full-scale HNB beamline. An overview of the current status of the neutral beam (NB) systems and the chosen configuration will be given and the ongoing integration effort into the ITER plant will be highlighted. It will be demonstrated how installation and maintenance logistics have influenced the design, notably the top access scheme facilitating access for maintenance and installation. The impact of the ITER Design Review and recent design change requests (DCRs) will be briefly discussed, including start-up and commissioning issues. The low current hydrogen phase now envisaged for start

  12. Status of the Negative Ion Based Heating and Diagnostic Neutral Beams for ITER

    International Nuclear Information System (INIS)

    Schunke, B.; Bora, D.; Hemsworth, R.; Tanga, A.

    2009-01-01

    The current baseline of ITER foresees 2 Heating Neutral Beam (HNB's) systems based on negative ion technology, each accelerating to 1 MeV 40 A of D - and capable of delivering 16.5 MW of D 0 to the ITER plasma, with a 3rd HNB injector foreseen as an upgrade option. In addition a dedicated Diagnostic Neutral Beam (DNB) accelerating 60 A of H - to 100 keV will inject ≅15 A equivalent of H 0 for charge exchange recombination spectroscopy and other diagnostics. Recently the RF driven negative ion source developed by IPP Garching has replaced the filamented ion source as the reference ITER design. The RF source developed at IPP, which is approximately a quarter scale of the source needed for ITER, is expected to have reduced caesium consumption compared to the filamented arc driven ion source. The RF driven source has demonstrated adequate accelerated D - and H - current densities as well as long-pulse operation. It is foreseen that the HNB's and the DNB will use the same negative ion source. Experiments with a half ITER-size ion source are on-going at IPP and the operation of a full-scale ion source will be demonstrated, at full power and pulse length, in the dedicated Ion Source Test Bed (ISTF), which will be part of the Neutral Beam Test Facility (NBTF), in Padua, Italy. This facility will carry out the necessary R and D for the HNB's for ITER and demonstrate operation of the full-scale HNB beamline. An overview of the current status of the neutral beam (NB) systems and the chosen configuration will be given and the ongoing integration effort into the ITER plant will be highlighted. It will be demonstrated how installation and maintenance logistics have influenced the design, notably the top access scheme facilitating access for maintenance and installation. The impact of the ITER Design Review and recent design change requests (DCRs) will be briefly discussed, including start-up and commissioning issues. The low current hydrogen phase now envisaged for start

  13. In vivo effects of olanzapine on striatal dopamine D[sub 2]/D[sub 3] receptor binding in schizophrenic patients: an iodine-123 iodobenzamide single-photon emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, S.; Rossmueller, B.; Hahn, K.; Tatsch, K. (Department of Nuclear Medicine, University of Munich (Germany)); Mager, T.; Meisenzahl, E.; Moeller, H.J. (Department of Psychiatry, University of Munich (Germany))

    1999-08-01

    Olanzapine is a new atypical antipsychotic agent that belongs to the same chemical class as clozapine. The pharmacological efficacy of olanzapine (in contrast to that of risperidone) has been shown to be comparable to that of clozapine, but olanzapine has the advantage of producing a less pronounced bone marrow depressing effect than clozapine. The specific aims of this study were (a) to assess dopamine D[sub 2]/D[sub 3] receptor availability in patients treated with olanzapine by means of iodine-123 iodobenzamide [[sup 123]I]IBZM single-photon emission tomography (SPET), (b) to compare the results with findings of [[sup 123]I]IBZM SPET in patients under treatment with risperidone and (c) to correlate the results with the occurrance of extrapyramidal side-effects (EPMS). Brain SPET scans were performed in 20 schizophrenic patients (DSM III R) at 2 h after i.v. administration of 185 MBq [[sup 123]I]IBZM. Images were acquired using a triple-head gamma camera (Picker Prism 3000 XP). For semiquantitative evaluation of D[sub 2]/D[sub 3] receptor binding, transverse slices corrected for attenuation were used to calculate specific uptake values [STR-BKG]/BKG (STR=striatum; BKG=background). The mean daily dose of olanzapine ranged from 0.05 to 0.6 mg/kg body weight. The dopamine D[sub 2]/D[sub 3] receptor binding was reduced in all patients treated with olanzapine. Specific IBZM binding [STR-BKG]/BKG ranged from 0.13 to 0.61 (normal controls >0.95). The decreased D[sub 2]/D[sub 3] receptor availability revealed an exponential dose-response relationship (r=-0.85, P<0.001). The slope of the curve was similar to that of risperidone and considerably higher than that of clozapine as compared with the results of a previously published study. EPMS were observed in only one patient, presenting with the lowest D[sub 2]/D[sub 3] availability. The frequency of EPMS induced by olanzapine (5%) was considerably lower than the frequency under risperidone treatment (40%). Our findings

  14. In vivo effects of olanzapine on striatal dopamine D{sub 2}/D{sub 3} receptor binding in schizophrenic patients: an iodine-123 iodobenzamide single-photon emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, S.; Rossmueller, B.; Hahn, K.; Tatsch, K. [Department of Nuclear Medicine, University of Munich (Germany); Mager, T.; Meisenzahl, E.; Moeller, H.J. [Department of Psychiatry, University of Munich (Germany)

    1999-08-01

    Olanzapine is a new atypical antipsychotic agent that belongs to the same chemical class as clozapine. The pharmacological efficacy of olanzapine (in contrast to that of risperidone) has been shown to be comparable to that of clozapine, but olanzapine has the advantage of producing a less pronounced bone marrow depressing effect than clozapine. The specific aims of this study were (a) to assess dopamine D{sub 2}/D{sub 3} receptor availability in patients treated with olanzapine by means of iodine-123 iodobenzamide [{sup 123}I]IBZM single-photon emission tomography (SPET), (b) to compare the results with findings of [{sup 123}I]IBZM SPET in patients under treatment with risperidone and (c) to correlate the results with the occurrance of extrapyramidal side-effects (EPMS). Brain SPET scans were performed in 20 schizophrenic patients (DSM III R) at 2 h after i.v. administration of 185 MBq [{sup 123}I]IBZM. Images were acquired using a triple-head gamma camera (Picker Prism 3000 XP). For semiquantitative evaluation of D{sub 2}/D{sub 3} receptor binding, transverse slices corrected for attenuation were used to calculate specific uptake values [STR-BKG]/BKG (STR=striatum; BKG=background). The mean daily dose of olanzapine ranged from 0.05 to 0.6 mg/kg body weight. The dopamine D{sub 2}/D{sub 3} receptor binding was reduced in all patients treated with olanzapine. Specific IBZM binding [STR-BKG]/BKG ranged from 0.13 to 0.61 (normal controls >0.95). The decreased D{sub 2}/D{sub 3} receptor availability revealed an exponential dose-response relationship (r=-0.85, P<0.001). The slope of the curve was similar to that of risperidone and considerably higher than that of clozapine as compared with the results of a previously published study. EPMS were observed in only one patient, presenting with the lowest D{sub 2}/D{sub 3} availability. The frequency of EPMS induced by olanzapine (5%) was considerably lower than the frequency under risperidone treatment (40%). Our findings

  15. Comorbidity negatively influences the outcomes of diagnostic tests for musculoskeletal pain in the orofacial region.

    Science.gov (United States)

    Koutris, Michail; Visscher, Corine M; Lobbezoo, Frank; Naeije, Machiel

    2013-06-01

    The aim of this study was to investigate whether diagnostic tests for musculoskeletal pain in the orofacial region [temporomandibular disorder (TMD) pain] are influenced by the presence of comorbid conditions, and to determine whether this influence decreases when the presence of "familiar pain" is used as outcome measure. In total, 117 patients (35 men, 82 women; 75 TMD-pain patients, 42 pain-free patients; mean age ± SD = 42.94 ± 14.17 years) were examined with palpation tests and dynamic/static tests. After each test, they were asked whether any pain was provoked and whether this pain response was familiar or not. For four clinical outcome measures (pain on palpation, familiar pain on palpation, pain on dynamic/static tests, and familiar pain on dynamic/static tests), multiple logistic regression analyses were performed with the presence of TMD pain as the primary predictor and regional (neck/shoulder) pain, widespread pain, depression, and somatization as comorbid factors. Pain on palpation was not associated with the primary predictor but with regional pain [P = 0.02, odds ratio (OR) = 4.59] and somatization (P = 0.011, OR = 8.47), whereas familiar pain on palpation was associated with the primary predictor (P = 0.003, OR = 5.23), but also with widespread pain (P = 0.001, OR = 2.02). Pain on dynamic/static tests was associated with the primary predictor (P pain on dynamic/static tests was only associated with the primary predictor (P diagnostic tests are negatively influenced by the presence of comorbidity. This influence decreases when the presence of familiar pain is used as outcome measure. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  16. Numerical experiment to estimate the validity of negative ion diagnostic using photo-detachment combined with Langmuir probing

    Energy Technology Data Exchange (ETDEWEB)

    Oudini, N. [Laboratoire des plasmas de décharges, Centre de Développement des Technologies Avancées, Cité du 20 Aout BP 17 Baba Hassen, 16081 Algiers (Algeria); Sirse, N.; Ellingboe, A. R. [Plasma Research Laboratory, School of Physical Sciences and NCPST, Dublin City University, Dublin 9 (Ireland); Benallal, R. [Unité de Recherche Matériaux et Energies Renouvelables, BP 119, Université Abou Bekr Belkaïd, Tlemcen 13000 (Algeria); Taccogna, F. [Istituto di Metodologie Inorganiche e di Plasmi, CNR, via Amendola 122/D, 70126 Bari (Italy); Aanesland, A. [Laboratoire de Physique des Plasmas, (CNRS, Ecole Polytechnique, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud), École Polytechnique, 91128 Palaiseau Cedex (France); Bendib, A. [Laboratoire d' Electronique Quantique, Faculté de Physique, USTHB, El Alia BP 32, Bab Ezzouar, 16111 Algiers (Algeria)

    2015-07-15

    This paper presents a critical assessment of the theory of photo-detachment diagnostic method used to probe the negative ion density and electronegativity α = n{sub -}/n{sub e}. In this method, a laser pulse is used to photo-detach all negative ions located within the electropositive channel (laser spot region). The negative ion density is estimated based on the assumption that the increase of the current collected by an electrostatic probe biased positively to the plasma is a result of only the creation of photo-detached electrons. In parallel, the background electron density and temperature are considered as constants during this diagnostics. While the numerical experiments performed here show that the background electron density and temperature increase due to the formation of an electrostatic potential barrier around the electropositive channel. The time scale of potential barrier rise is about 2 ns, which is comparable to the time required to completely photo-detach the negative ions in the electropositive channel (∼3 ns). We find that neglecting the effect of the potential barrier on the background plasma leads to an erroneous determination of the negative ion density. Moreover, the background electron velocity distribution function within the electropositive channel is not Maxwellian. This is due to the acceleration of these electrons through the electrostatic potential barrier. In this work, the validity of the photo-detachment diagnostic assumptions is questioned and our results illustrate the weakness of these assumptions.

  17. Analysis of the influence of the current of a negative ion beam on its diagnostics by means of detachment electrons

    International Nuclear Information System (INIS)

    Artemov, A.S.

    1997-01-01

    The influence of the field of a negative ion beam on information about its characteristics, transferred by detachment electrons after a probing internal target, is considered. The perturbations of the momentum components of electrons during their extraction out of the beam by means of a 180 degree magnetic analyzer with a homogeneous field, are calculated in the model of infinite cylinder with a uniformly cross section distributed current. The obtained results show that the method of nonperturbative diagnostics of a negative ion beam by means of photodetachment electrons can be used successfully for relativistic beams with a current of hundreds of milliampers, for example, in projected neutron sources based on linear accelerators

  18. Comorbidity negatively influences the outcomes of diagnostic tests for musculoskeletal pain in the orofacial region

    NARCIS (Netherlands)

    Koutris, M.; Visscher, C.M.; Lobbezoo, F.; Naeije, M.

    2013-01-01

    The aim of this study was to investigate whether diagnostic tests for musculoskeletal pain in the orofacial region [temporomandibular disorder (TMD) pain] are influenced by the presence of comorbid conditions, and to determine whether this influence decreases when the presence of "familiar pain" is

  19. Artificial neural networks as classification and diagnostic tools for lymph node-negative breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Eswari J, Satya; Chandrakar, Neha [National Institute of Technology Raipur, Raipur (India)

    2016-04-15

    Artificial neural networks (ANNs) can be used to develop a technique to classify lymph node negative breast cancer that is prone to distant metastases based on gene expression signatures. The neural network used is a multilayered feed forward network that employs back propagation algorithm. Once trained with DNA microarraybased gene expression profiles of genes that were predictive of distant metastasis recurrence of lymph node negative breast cancer, the ANNs became capable of correctly classifying all samples and recognizing the genes most appropriate to the classification. To test the ability of the trained ANN models in recognizing lymph node negative breast cancer, we analyzed additional idle samples that were not used beforehand for the training procedure and obtained the correctly classified result in the validation set. For more substantial result, bootstrapping of training and testing dataset was performed as external validation. This study illustrates the potential application of ANN for breast tumor diagnosis and the identification of candidate targets in patients for therapy.

  20. Castellated tiles as the beam-facing components for the diagnostic calorimeter of the negative ion source SPIDER.

    Science.gov (United States)

    Peruzzo, S; Cervaro, V; Dalla Palma, M; Delogu, R; De Muri, M; Fasolo, D; Franchin, L; Pasqualotto, R; Pimazzoni, A; Rizzolo, A; Tollin, M; Zampieri, L; Serianni, G

    2016-02-01

    This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.

  1. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    In order to support the operation of ITER and the planned experimental programme an extensive set of plasma and first wall measurements will be required. The number and type of required measurements will be similar to those made on the present-day large tokamaks while the specification...... of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  2. Diagnostic yield of Bronchoalveolar Lavage gene Xpert in smear-negative and sputum-scarce pulmonary tuberculosis.

    Science.gov (United States)

    Khalil, Kanwal Fatima; Butt, Tariq

    2015-02-01

    To measure the diagnostic yield of Bronchoalveolar Lavage (BAL) gene Xpert (Xpert MTB/RIF assay), to detect Mycobacterium tuberculosis (MTB) and rifampicin resistance and compare it with that of mycobacterial cultures in a suspected case of pulmonary tuberculosis. An analytical study. Department of Pulmonology, Fauji Foundation Hospital (FFH), Rawalpindi, from December 2012 to August 2013. BAL specimens of 93 patients with suspected pulmonary tuberculosis with smear-negative or sputumscarce disease, who presented to the Department of Pulmonology, FFH, Rawalpindi were inducted. A smear-negative case was one in whom three consecutive early morning sputum samples did not reveal acid fast bacilli when examined by microscopy with Zeihl Nelson (ZN) stain. Patients who had sputum amount less than 1 ml were defined to have sputumscarce disease. The same was evaluated with ZN stain, gene Xpert and mycobacterial cultures. Sensitivity analysis was carried out using culture as the gold standard. The frequency of positive mycobacterial cultures was 85 (91.4%). The sensitivity, specificity, positive predictive value and negative predictive values of BAL gene Xpert to detect Mycobacterium tuberculosis were 91.86%, 71.42%, 97.53% and 41.66% respectively. Xpert MTB/RIF assay had a sensitivity and specificity of 83.33% and 100% to detect rifampicin resistance. Bronchoalveolar lavage gene Xpert had a superior diagnostic yield in patients with either smear-negative or sputum-scarce pulmonary tuberculosis. Hence a positive Xpert MTB/RIF assay may be a useful adjunct to diagnosis and detection of MDR-TB in bronchoalveolar lavage specimens.

  3. Diagnostic performance of a biomarker panel as a negative predictor for acute appendicitis in adult ED patients with abdominal pain.

    Science.gov (United States)

    Huckins, David S; Copeland, Karen; Self, Wesley; Vance, Cheryl; Hendry, Phyllis; Borg, Keith; Gogain, Joseph

    2017-03-01

    Evaluate the diagnostic accuracy of the APPY1TM biomarker panel, previously described for use in pediatric patients, for identifying adult ED patients with abdominal pain who are at low risk of acute appendicitis. This study prospectively enrolled subjects >18years of age presenting to seven U.S. emergency departments with pain suggesting possible acute appendicitis. The APPY1 panel was performed on blood samples drawn from each patient at the time of initial evaluation and results were correlated with the final diagnosis either positive or negative for acute appendicitis. 431 patients were enrolled with 422 completing all aspects of the study. The APPY1 biomarker panel exhibited a sensitivity of 97.5% (95% CI, 91.3-99.3%), a negative predictive value of 98.4% (95% CI, 94.4-99.6%), a negative likelihood ratio of 0.07 (95% CI, 0.02-0.27), with a specificity of 36.5% (95% CI, 31.6-41.8%) for acute appendicitis. The panel correctly identified 125 of 342 (36.6%) patients who did not have appendicitis with 2 (2.5%) false negatives. The CT utilization rate in this population was 72.7% (307/422). Of 307 CT scans, 232 were done for patients who did not have appendicitis and 79 (34%) of these patients were correctly identified as negative with "low risk" biomarker panel results, representing 26% (79/307) of all CT scans performed. This biomarker panel exhibited high sensitivity and negative predictive value for acute appendicitis in this prospective adult cohort, thereby potentially reducing the dependence on CT for the evaluation of possible acute appendicitis. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Negative and positive participant responses to the composite international diagnostic interview - Results of the Netherlands Mental Health Survey and Incidence Study

    NARCIS (Netherlands)

    Graaf, R. de; Have, M.L. ten; Dorsselaer, S.A.F.M. van; Schoemaker, C.G.; Vollebergh, W.A.M.

    2004-01-01

    Little is known about the emotional responses of participants in community surveys to standardised psychiatric interviews like the Composite International Diagnostic Interview (CIDI). This study investigates the proportion of subjects responding negatively or positively to the CIDI, and identifies

  5. Comparison of iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Ahonen, A. [Dept. of Clinical Chemistry, Oulu Univ. Central Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Laensimies, E. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Wang Shaoyin [Research Biochemicals International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemicals International (RBI), Natick, MA (United States)

    1995-04-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane ([{sup 123}I]{beta}-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [{sup 123}I]{beta}-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([{sup 123}I]{beta}-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [{sup 123}I]{beta}-CIT (>8 h). However, the specific DAT binding of [{sup 123}I]{beta}-CIT-FP in the basal ganglia was somewhat less (0.813{+-}0.047) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  6. Comparison of iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)tropane and 2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Ahonen, A.; Hiltunen, J.; Haukka, J.; Laensimies, E.; Wang Shaoyin; Neumeyer, J.L.

    1995-01-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)tropane ([ 123 I]β-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [ 123 I]β-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [ 123 I]β-CIT and 2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([ 123 I]β-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [ 123 I]β-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [ 123 I]β-CIT (>8 h). However, the specific DAT binding of [ 123 I]β-CIT-FP in the basal ganglia was somewhat less (0.813±0.047) than that of [ 123 I]β-CIT (0.922±0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  7. Defensive mobilization in specific phobia: fear specificity, negative affectivity, and diagnostic prominence.

    Science.gov (United States)

    McTeague, Lisa M; Lang, Peter J; Wangelin, Bethany C; Laplante, Marie-Claude; Bradley, Margaret M

    2012-07-01

    Understanding of exaggerated responsivity in specific phobia-its physiology and neural mediators-has advanced considerably. However, despite strong phenotypic evidence that prominence of specific phobia relative to co-occurring conditions (i.e., principal versus nonprincipal disorder) is associated with dramatic differences in subjective distress, there is yet no consideration of such comorbidity issues on objective defensive reactivity. A community sample of specific phobia (n = 74 principal; n = 86 nonprincipal) and control (n = 76) participants imagined threatening and neutral events while acoustic startle probes were presented and eyeblinks (orbicularis occuli) recorded. Changes in heart rate, skin conductance level, and facial expressivity were also measured. Principal specific phobia patients far exceeded control participants in startle reflex and autonomic reactivity during idiographic fear imagery. Distinguishing between single and multiple phobias within principal phobia and comparing these with nonprincipal phobia revealed a continuum of decreasing defensive mobilization: single patients were strongly reactive, multiple patients were intermediate, and nonprincipal patients were attenuated-the inverse of measures of pervasive anxiety and dysphoria (i.e., negative affectivity). Further, as more disorders supplanted specific phobia from principal disorder, overall defensive mobilization was systematically more impaired. The exaggerated responsivity characteristic of specific phobia is limited to those patients for whom circumscribed fear is the most impairing condition and coincident with little additional affective psychopathology. As specific phobia is superseded in severity by broad and chronic negative affectivity, defensive reactivity progressively diminishes. Focal fears may still be clinically significant but not reflected in objective defensive mobilization. Copyright © 2012 Society of Biological Psychiatry. Published by Elsevier Inc. All rights

  8. Diagnostic value of recombinant human thyrotropin-stimulated ¹²³I whole-body scintigraphy in the follow-up of patients with differentiated thyroid cancer.

    Science.gov (United States)

    Alzahrani, Ali S; AlShaikh, OmAlkhaire; Tuli, Mahmoud; Al-Sugair, Abdulaziz; Alamawi, Reem; Al-Rasheed, Maha M

    2012-03-01

    Published data on recombinant human thyrotropin- (rhTSH-) stimulated iodine-123 (¹²³I) diagnostic whole-body scintigraphy (DxWBS) in differentiated thyroid cancer (DTC) surveillance after initial treatment are limited. We sought to evaluate this modality's diagnostic value in this setting. We retrospectively compared rhTSH-stimulated ¹²³I DxWBS results with DTC status concurrently determined by stimulated serum thyroglobulin (Tg) measurement, neck ultrasonography, and other imaging studies. Disease was considered present based on stimulated Tg level ≥1 μg/L without interfering Tg autoantibodies with or without positive imaging or biopsy-proven DTC. We also compared scan positivity and disease detection rates of rhTSH-stimulated DxWBS scans obtained with ¹²³I with those acquired with iodine-131 (¹³¹I) during the same period. The sample comprised 105 consecutive totally thyroidectomized patients undergoing rhTSH-aided DxWBS with I-123 (n = 67) or with ¹³¹I (n = 38) for diagnostic follow-up. rhTSH, 0.9 mg/d, was injected intramuscularly on 2 consecutive days. Oral diagnostic activities of 5 to 10 mCi (185-370 MBq) ¹²³I or 3 mCi (111 MBq) ¹³¹I were given on the third day. DxWBS was performed 24 hours (¹²³I) or 48 to 72 hours (¹³¹I) later. rhTSH-aided ¹²³I DxWBS scans showed 35.3% sensitivity, 98.0% specificity, 85.7% positive predictive value, and 81.6% negative predictive value. rhTSH-stimulated ¹²³I and ¹³¹I DxWBS did not differ in scan positivity (10.4% vs. 13.2%, P = 0.75) or disease detection rates (35.3% vs. 27.8%, P = 1.00). In DTC, rhTSH-aided ¹²³I DxWBS achieves comparable results in diagnostic follow-up with those of rhTSH-aided ¹³¹I DxWBS. Future studies should address the preablation setting and scan activity and timing.

  9. An evaluation of the New Roche Diagnostics Kit for the rapid identification of clinically important non-dextrose, non-fastidious gram-negative rods.

    Science.gov (United States)

    Elegbe, I A

    1980-01-01

    The evaluation of the new Roche Diagnostics Commercial kit (Roche Diagnostics, 1975) for the identification of non-dextrose fermenting, non-fastidious gram-negative rods has been compared with conventional methods in the recognition and identification of these non-dextrose, non-fastidious gram-negative bacteria. This new kit has definite advantages over and above the conventional methods in a number of ways. It is cheaper to run, and above all it is less cumbersome, less time consuming and it is accurate. Apart from all these, the new method makes use of the odour test (Roche Diagnostics, 1975) and other additional conventional tests recommended by the Oxi/ferm manufacturer.

  10. Negative transcriptional control of ERBB2 gene by MBP-1 and HDAC1: diagnostic implications in breast cancer

    International Nuclear Information System (INIS)

    Contino, Flavia; Mazzarella, Claudia; Ferro, Arianna; Lo Presti, Mariavera; Roz, Elena; Lupo, Carmelo; Perconti, Giovanni; Giallongo, Agata; Feo, Salvatore

    2013-01-01

    The human ERBB2 gene is frequently amplified in breast tumors, and its high expression is associated with poor prognosis. We previously reported a significant inverse correlation between Myc promoter-binding protein-1 (MBP-1) and ERBB2 expression in primary breast invasive ductal carcinoma (IDC). MBP-1 is a transcriptional repressor of the c-MYC gene that acts by binding to the P2 promoter; only one other direct target of MBP-1, the COX2 gene, has been identified so far. To gain new insights into the functional relationship linking MBP-1 and ERBB2 in breast cancer, we have investigated the effects of MBP-1 expression on endogenous ERBB2 transcript and protein levels, as well as on transcription promoter activity, by transient-transfection of SKBr3 cells. Reporter gene and chromatin immunoprecipitation assays were used to dissect the ERBB2 promoter and identify functional MBP-1 target sequences. We also investigated the relative expression of MBP-1 and HDAC1 in IDC and normal breast tissues by immunoblot analysis and immunohistochemistry. Transfection experiments and chromatin immunoprecipitation assays in SKBr3 cells indicated that MBP-1 negatively regulates the ERBB2 gene by binding to a genomic region between nucleotide −514 and −262 of the proximal promoter; consistent with this, a concomitant recruitment of HDAC1 and loss of acetylated histone H4 was observed. In addition, we found high expression of MBP-1 and HDAC1 in normal tissues and a statistically significant inverse correlation with ErbB2 expression in the paired tumor samples. Altogether, our in vitro and in vivo data indicate that the ERBB2 gene is a novel MBP-1 target, and immunohistochemistry analysis of primary tumors suggests that the concomitant high expression of MBP-1 and HDAC1 may be considered a diagnostic marker of cancer progression for breast IDC

  11. Quantitative iodine-123 IMP imaging of brain perfusion in schizophrenia

    International Nuclear Information System (INIS)

    Cohen, M.B.; Lake, R.R.; Graham, L.S.

    1989-01-01

    Decreased perfusion in the frontal lobes of patients with chronic schizophrenia has been reported by multiple observes using a variety of techniques. Other observers have been unable to confirm this finding using similar techniques. In this study quantitative single photon emission computed tomography brain imaging was performed using p,5n [ 123 I]IMP in five normal subjects and ten chronically medicated patients with schizophrenia. The acquisition data were preprocessed with an image dependent Metz filter and reconstructed using a ramp filtered back projection technique. The uptake in each of 50 regions of interest in each subject was normalized to the uptake in the cerebellum. There were no significant confirmed differences in the comparable ratios of normal subjects and patients with schizophrenia even at the p = 0.15 level. Hypofrontality was not observed

  12. Apparatus of hot cell for iodine-123 production

    International Nuclear Information System (INIS)

    Almeida, G.L. de; Rautenberg, F.A.; Souza, A.S.F. de.

    1986-01-01

    The hot cell installation at IEN cyclotron (Brazilian-CNEN) for sup(123)I production is presented. Several devices, such as, tube furnace coupling system, tube furnace driving system, sup(123)I target transfer system, product extraction system, furnace control system, and effluent systems, were constructed and modified for implanting process engineering. The requirements of safety engineering for operation process were based on ALARA concept. (M.C.K.)

  13. Iodine 123 radiolabeling of monoclonal antibodies for in vivo procedures

    International Nuclear Information System (INIS)

    Mills, S.L.; Denardo, S.J.; Denardo, G.L.; Epstein, A.L.; Peng, J.S.; Colcher, D.

    1986-01-01

    When labeled to monoclonal antibodies (MAbs) or their fragments, 123 I can be used for imaging or for predicting the treatment potential and radiation dosimetry of 131 I labeled to the same molecular species. Because 123 I (p,5n) from the Crocker Nuclear Laboratory is in dilute solution, when compared with commercial 125 I of labeling grade, we have evaluated labeling parameters using Chloramine-T as the oxidant and derived an optimum set of labeling conditions that provide a 60-80% radiochemical yield of highly immunoreactive antibody. When Lym-1, an IgG-2a murine antibody against human lymphoma, was used, yields of labeled immunoglobulin were decreased by protein or Chloramine-T concentrations less than 0.4 microgram/microliter and 0.8 microgram/microliter, respectively; denaturation of the immunoglobulin occurred when the Chloramine-T concentration was greater than 1.0 microgram/microliter. Optimum labeling occurred at pH 7-8 with deleterious effects when the pH was below 5 or above 10. An optimum method for labeling antibodies with multimillicurie amounts of 123 I (less than one iodine atom per 100 antibody molecules) is described. Some of the observations derived from this study are also applicable to the preparation of treatment doses of 131 I-labeled antibodies, wherein the amount of antibody can be a restrictive factor

  14. Pitfalls in clinical assessment of neurotoxic diseases: negative effects of repeated diagnostic evaluation, illustrated by a clinical case

    NARCIS (Netherlands)

    van Hout, Moniek; Hageman, Gerard; van Valen, Evelien

    2014-01-01

    Exposure to different toxic substances can have acute and chronic neurological and neuropsychiatric health effects on humans. Patients often report impaired concentration and memory, irritability, fatigue, instability of affect and difficulties in impulse control. The diagnostic process for

  15. Molecular evidence of malaria and zoonotic diseases among rapid diagnostic test-negative febrile patients in low-transmission season, Mali

    DEFF Research Database (Denmark)

    Touré, Mahamoudou; Petersen, Pelle T; Bathily, Sidy N'd

    2017-01-01

    tools. Plasmodium sp. was present among 57 (60.2%) of the 88 malaria RDT-negative patients, whereas the prevalence of Borrelia, C. burnetii, and Babesia were 3.4% (N = 3), 1.1% (N = 1), and 0.0%, respectively. The additional diagnostic use of polymerase chain reaction (PCR) identified a high proportion...... of Plasmodium sp.-positive samples and although this may be a concern for malaria control, the respective PCR-identified malaria infections were less likely responsible for the observed fevers given the low parasite density. Also, the low infection levels of Borrelia and C. burnetii and lack of Babesia among......From November to December 2012 in Sélingué-Mali, blood samples from 88 febrile patients who tested negative by malaria Paracheck (®) rapid diagnostic tests (RDTs) were used to assess the presence of sub-RDT Plasmodium falciparum as well as Borrelia, Coxiella burnetii, and Babesia applying molecular...

  16. Symptomatic predictors for 2009 influenza A virus (H1N1 infection with an emphasis for patients with a negative rapid diagnostic test.

    Directory of Open Access Journals (Sweden)

    Chen-Yen Kuo

    Full Text Available BACKGROUND: The clinical diagnosis of influenza is difficult because it shares nonspecific symptoms with a variety of diseases. Emergency departments and clinics were overwhelmed by a surge of anxious patients during the 2009 influenza A virus (H1N1 outbreak. Our objective was to identify symptomatic predictors of influenza virus infection for patients with a negative rapid diagnostic test. METHODOLOGY/PRINCIPAL FINDINGS: We conducted a retrospective review of 805 patients who presented at Chang Gung Memorial Hospital, from August 1, 2009, to September 30, 2009. Respiratory specimens from these patients were subjected to rapid influenza tests and reverse-transcription polymerase chain reactions. In total, 36% of 308 children and 23% of 497 adults were positive for 2009 influenza A virus (H1N1 infection by polymerase chain reaction or virus culture. For pediatric patients, sore throat and influenza-like illness significantly increased the odds of having 2009 influenza A virus (H1N1 infection, by more than 3-fold (95% confidence interval (CI: 1.9-7.3 and 7-fold (95% CI: 4.00-14.2, respectively. For adult patients, cough and constitutional symptoms increased the odds of having 2009 influenza A virus (H1N1 by greater than 5-fold (95% CI: 3.1-10.2 and 3-fold (95% CI: 2.1-6.7, respectively. The negative likelihood ratio of the combination of fever and cough was 0.096 (95% CI: 0.01-0.69 for children with negative results of rapid influenza diagnostic tests. CONCLUSION/SIGNIFICANCE: In influenza epidemic settings, clinicians should be aware that rapid influenza diagnostic tests are relatively insensitive for the diagnosis of influenza virus infection. For patients with negative rapid influenza diagnostic tests, those lacking fever and cough have a low probability of influenza virus infection. The management strategy should be made individually and depend on the severity of illness.

  17. The diagnostic accuracy of biomarkers for diagnosis of primary biliary cholangitis (PBC) in anti-mitochondrial antibody (AMA)-negative PBC patients: a review of literature.

    Science.gov (United States)

    de Liso, Federica; Matinato, Caterina; Ronchi, Mariangela; Maiavacca, Rita

    2017-11-27

    Primary biliary cholangitis (PBC), also known as primary biliary cirrhosis, is an autoimmune disease of the liver characterized by anti-mitochondrial antibodies (AMA) in 90%-95% of patients. The aim of this study was to evaluate the diagnostic value of several serum biomarkers in patients with PBC but negative for AMA. Some antinuclear antibodies (ANA) pattern, detected by indirect immunofluorescence (IIF), such as multiple nuclear dot (MND) and rim-like patterns are well-known to be specific for PBC. The corresponding nuclear antigens are the components of the nuclear pore complex (Gp210 for rim-like pattern) and Sp100, PML proteins (for MND pattern) detectable by immunoblotting and ELISA methods. More recently, new biomarkers have been evaluated in order to improve the diagnostic sensitivity, such as kelch-like 12 (KLHL12) and hexokinase-1. Considering these different serum biomarkers, studies evaluating their diagnostic role in AMA-negative PBC patients compared to AMA-positive ones and controls were included in this review. Pooled sensitivity and specificity were 37% and 85%, respectively. The overall PPV and NPV mean values were 45% and 83%. Even if all biomarkers are very specific for PBC, the overall sensitivity was poor and therefore is necessary to identify a marker with a greater sensitivity for PBC in AMA-negative patients.

  18. Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation study

    Directory of Open Access Journals (Sweden)

    Vickers Andrew J

    2008-11-01

    Full Text Available Abstract Background A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives. Methods A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC corrected for verification bias varying both the rate and mechanism of verification. Results In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5th – 97.5th centile range constituted as much as 60% of the possible range of AUCs for some simulations. Conclusion Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.

  19. Challenges in culture-negative cases of Madurella mycetomatis: A case report re-accentuating PCR as an essential diagnostic tool.

    Science.gov (United States)

    K, S; Das, S; Pandhi, D; Rai, G; Ansari, M A; Gupta, C; Haque, S; Dar, S A

    2017-12-01

    Identification of dematiaceous fungi responsible for black-grain mycetoma has remained cumbersome and time consuming for years leading to delayed diagnosis and thereby increased agony to patients. Moreover, difficult morphology of some of these fungi demanding enough expertise for species identification in addition to culture-negativity has often led to misdiagnosis and hence inapt treatment to the patients. We report the identification of Madurella mycetomatis from culture-negative black granules discharged from foot nodular lesions of a 27 years old male using PCR followed by sequencing of the internal transcribed spacer region. The patient's lesions were successfully treated using a combination of itraconazole (200mg) and terbinafine (250mg), confirming our diagnosis. Our case study proves the clinical value of PCR as the best, rapid and accurate diagnostic method for the identification of Madurella mycetomatis and related fungi, particularly in culture-negative cases. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. The diagnostic value of 11C-methionine PET in hyperparathyroidism with negative 99mTc-MIBI SPECT: a meta-analysis.

    Science.gov (United States)

    Yuan, Leilei; Liu, Jun; Kan, Ying; Yang, Jigang; Wang, Xufu

    2017-05-01

    Background 99mTc-sestamibi (MIBI) parathyroid SPECT is generally regarded as the best preoperative localizing method in patients with hyperparathyroidism (HPT). However, 99mTc-MIBI SPECT is false negative in approximately 25% of adenomas. 11C-methionine positron emission tomography (PET) has been used in HPT with negative 99mTc-MIBI SPECT scan results. Purpose To systematically review and conduct a meta-analysis of published data on the performance of 11C-methionine PET in patients with HPT with negative 99mTc-MIBI SPECT. Material and Methods A comprehensive review of the literature was performed. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT and a negative 99mTc-MIBI SPECT was calculated on a per-patient basis using receiver-operating characteristic (ROC) methodology. Results Nine studies that met all inclusion and exclusion criteria were included into our meta-analysis, comprising a total sample size of 137 patients. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT with negative or inconclusive 99mTc-MIBI SPECT scans was 86% and 86%, respectively. The area under the ROC curve was 0.87. Conclusion By merit of the high overall sensitivity, specificity, and accuracy, 11C-methionine PET can potentially complement the diagnostic workup of patients with HPT and negative or inconclusive 99mTc-MIBI SPECT. 11C-methionine PET appears to be a promising diagnostic modality in complicated cases with HPT.

  1. Appreciation of CT-negative, lumbar puncture-positive subarachnoid haemorrhage: risk factors for presence of aneurysms and diagnostic yield of imaging.

    Science.gov (United States)

    Bakker, Nicolaas A; Groen, Rob J M; Foumani, Mahrouz; Uyttenboogaart, Maarten; Eshghi, Omid S; Metzemaekers, Jan D M; Luijckx, Gert Jan; Van Dijk, J Marc C

    2014-08-01

    Patients without a subarachnoid haemorrhage (SAH) on brain CT scan (CT-negative), but a lumbar puncture (LP)-proven SAH, are a challenging patient category. The optimal diagnostic approach is still a matter of debate. Also, there is little knowledge on the probability of finding an underlying vascular lesion. In this observational study, a consecutive cohort of 94 patients with CT-negative, LP-positive SAH was prospectively collected between 1998 and 2013. The yield of diagnostic modalities as well as patient outcome was studied. In addition, risk factors for the presence of a vascular lesion were analysed. In 40 patients (43%), an intracranial vascular abnormality was detected: 37 aneurysms and three arterial dissections. Female gender was significantly associated with detection of a vascular lesion. Time between ictus and diagnosis of SAH was not associated with the presence of vascular pathology. Overall, 99% of patients had a modified Rankin Score of 0-2 after a median follow-up of 72 months. The yield of additional digital subtraction angiography in patients with a negative CT angiography was zero. In this study, the chance of finding a vascular lesion in a patient with CT-negative, LP-positive SAH was 43%, underlining the need for an adequate diagnostic workup. In general, the patient outcome was favourable. Female gender was found to be predictive for detecting a vascular lesion. In contrast with previous reports, the interval between ictus and LP was not associated with the presence of an aneurysm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Diagnostic Value of Endoscopic Ultrasonography in Symptomatic Patients with High and Intermediate Probabilities of Common Bile Duct Stones and a Negative Computed Tomography Scan

    Science.gov (United States)

    Jeon, Tae Joo; Cho, Jae Hee; Kim, Yeon Suk; Song, Si Young; Park, Ji Young

    2017-01-01

    Background/Aims When computed tomography (CT) does not indicate choledocholithiasis in highly suspicious patients, there is no definite consensus on the subsequent modality. Endoscopic ultrasonography (EUS) indicates fewer procedure-related complications than endoscopic retrograde cholangiopancreatography (ERCP) and has a lower cost than magnetic resonance cholangiopancreatography. Therefore, we aimed to investigate the diagnostic value of EUS in patients with suspected choledocholithiasis and negative CT findings. Methods Between March 2008 and November 2014, we retrospectively evaluated 200 patients with negative CT findings and high or intermediate probabilities of choledocholithiasis. All patients initially underwent EUS followed by ERCP as a confirmatory criterion standard. The primary outcome in these patients was the accuracy of EUS in the detection of choledocholithiasis. The secondary outcome was the clinical prediction of common bile duct (CBD) stones in this group. Results EUS indicated choledocholithiasis in 165 of the 200 patients, and ERCP confirmed choledocholithiasis in 161 patients (80.5%). The accuracy of EUS in the detection of choledocholithiasis was 94.0% (sensitivity, 97.5%; specificity, 79.5%; positive predictive value, 95.2%; negative predictive value, 88.6%). A multivariate analysis demonstrated that choledocholithiasis was strongly predicted by EUS detection of choledocholithiasis, an age >55 years and a clinical diagnosis of cholangitis. Conclusions An EUS-first approach is recommended for patients with suspected CBD stones and negative CT findings. PMID:27965473

  3. Benefit of cerebrospinal fluid spectrophotometry in the assessment of CT scan negative suspected subarachnoid haemorrhage: a diagnostic accuracy study.

    Science.gov (United States)

    Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2015-01-01

    This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  4. TB diagnostic process management of patients in a referral hospital in Mozambique in comparison with the 2007 WHO recommendations for the diagnosis of smear-negative pulmonary TB and extrapulmonary TB

    NARCIS (Netherlands)

    Bos, Jeannet C.; Smalbraak, Lisette; Macome, Augusto C.; Gomes, Ermelinda; van Leth, Frank; Prins, Jan M.

    2013-01-01

    In sub-Saharan African countries, the high proportion of smear-negative pulmonary TB (SNTB) and extrapulmonary TB (EPTB) contributes to a delay in TB diagnosis and treatment. We evaluated the TB diagnostic process of adult patients with presumptive TB in a referral hospital in Mozambique according

  5. Clinical diagnosis of pandemic A(H1N1) 2009 influenza in children with negative rapid influenza diagnostic test by lymphopenia and lower C-reactive protein levels.

    Science.gov (United States)

    Wang, Lin; Chang, Ling-Sai; Lee, Ing-Kit; Tang, Kuo-Shu; Li, Chung-Chen; Eng, Hock-Liew; You, Huey-Ling; Yang, Kuender D

    2014-01-01

    The sensitivity of rapid influenza diagnostic test (RIDT) of children with influenza-like illness (ILI) remains low. We compare the parameters between pandemic A(H1N1) 2009 influenza with negative RIDT and ILI not H1N1 for improving the low sensitivity of RIDT for children with ILI. In a cohort of consecutive laboratory-confirmed H1N1 influenza, we identified 150 H1N1 children with positive RIDT, 152 H1N1 children with negative RIDT, and 75 children with ILI not H1N1. Viral load in throat, complete blood count (CBC), and C-reactive protein (CRP) levels between H1N1 children with negative RIDT and children with ILI not H1N1 were assessed. The diagnostic sensitivity of the RIDT was 45·5%. An analysis of CBC and CRP levels indicated that H1N1 children with negative RIDT had lower total leukocyte, neutrophil, lymphocyte, and basophil counts, and serum CRP levels (P diagnostic sensitivity of 52·5% and 80·7%, respectively. Combining the lymphocyte counts and CRP levels provided a diagnostic sensitivity of 91·5%. Moreover, H1N1 children with negative RIDT had a lower viral load than those with positive RIDT (3·33 versus 4·48 log10  copies/ml, P H1N1 children with false-negative RIDT, potentially facilitating differential diagnoses. © 2013 The Authors. Influenza and Other Respiratory Viruses published by John Wiley & Sons Ltd.

  6. [Positron emission tomography-computed tomography with (18)F-fluorodeoxyglucose in patients with recurrent differentiated thyroid carcinoma and negative radioiodine scan. Diagnostic performance and relation with tyroglobulin levels].

    Science.gov (United States)

    Mariscal Labrador, E; García Burillo, A; Castell-Conesa, J; Obiols Alfonso, G; Kisiel González, N; Barios Profitós, M; Aguadé-Bruix, S; Mesa Manteca, J

    2013-01-01

    To assess the diagnostic performance of (18)F-FDG PET-CT scan and its relation to serum thyroglobulin (Tg) levels in patients with differentiated thyroid carcinoma with suspicion of persistence or recurrence of the disease and negative radioiodine scans. This is a retrospective analysis of 35 PET-CT studies in 25 patients (17 women, average age 48.8±15.2 years). The results were confirmed by histology or by ultrasonography and clinical follow-up. We analyzed the relationship between the diagnostic performance of the PET-CT scans and three levels of Tg: ≤2ng/ml; between 2 and 10 ng/ml, and >10ng/ml. We obtained 26 true-positives (TP), one false-positive (FP), 3 true-negatives (TN) and 5 false-negatives (FN). Of the 18 patients with PET-CTs classified as TP, 3 showed lesions at the post-thyroidectomy bed, 15 showed lymph node metastases and 5 were distant metastases. Sensitivity was 83.9% (95%CI: 69.3%-98.4%) and specificity was 75% (95%CI: 20%-100%). Regarding the three intervals of Tg, PET-CT scan showed TP rates of 37.5%, 83% and 100% in patients with Tg levels 10ng/ml, respectively. (18)F-FDG PET-CT demonstrates high diagnostic yield in local disease and distant lesions for the population of patients with differentiated thyroid carcinoma and persistence of the disease with negative radioiodine scans at Tg levels above 2ng/ml. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.

  7. A Rare Multifocal Pattern of Type 2 Autoimmune Pancreatitis with Negative IgG4: A Potential Diagnostic Pitfall That May Mimic Multifocal Pancreatic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Partha Hota

    2018-02-01

    Full Text Available Autoimmune pancreatitis (AIP is an increasingly recognized form of acute pancreatitis characterized by obstructive jaundice with a rapid and dramatic treatment response to steroid therapy. Recently, AIP has been divided into two distinct phenotypes: lymphoplasmocytic sclerosing pancreatitis AIP (type 1 and idiopathic duct-centric pancreatitis AIP (type 2; each of which have their own distinct demographics, diagnostic criteria, and histopathological features. We report, to the best of our knowledge, the first case of a multifocal pattern of type 2 AIP characterized with both CT and MR imaging. This rare imaging pattern of AIP may mimic the appearance of more worrisome malignant etiologies such as multifocal pancreatic adenocarcinoma or lymphoma, with overlapping imaging characteristics potentially complicating or delaying diagnosis. Therefore, recognition of this atypical pattern of AIP and avoidance of this potential diagnostic pitfall is crucial.

  8. Diagnostic yield and clinical impact of routine cell culture for respiratory viruses among children with a negative multiplex RT-PCR result.

    Science.gov (United States)

    AlGhounaim, M; Xiao, Y; Caya, C; Papenburg, J

    2017-09-01

    Polymerase chain reaction (PCR) is the reference standard for respiratory virus testing. However, cell culture may still have added value in identifying viruses not detected by PCR. We aimed to estimate the yield and clinical impact of routine respiratory virus culture among children with a negative PCR result. A retrospective cohort study was performed from Jan. 2013 to Sept. 2015. Respiratory samples from hospitalized or immunocompromised patients culture monolayers if they tested negative by a PCR assay for 12 respiratory viruses. We studied patients with a respiratory specimen negative by PCR and positive by culture. Duplicates and samples of sold services were excluded. Data on demographics, clinical history, laboratory findings, and patient management were collected from patients' charts. Descriptive and multivariate statistics were performed. Overall, 4638 PCR-negative samples were inoculated in cell culture. Of those, 196 (4.2%) were cell culture positive, and 144 met study inclusion criteria. Most subjects (81.9%) were hospitalized. Mean age was 2.4±3.4years. The viruses most frequently isolated were cytomegalovirus (33.3%) and enteroviruses (19.4%). Cell culture results prompted a change in management in 5 patients (3.5%), all of whom had acyclovir initiated for localized HSV-1 infection. Four of these had skin or mucosal lesions that could be sampled to establish a diagnosis. In children, routine viral culture on respiratory specimens that were negative by PCR has low yield and minimal clinical impact. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. The diagnostic utility of matrix metalloproteinase-3 and high-sensitivity C-reactive protein for predicting rheumatoid arthritis in anti-cyclic citrullinated peptide antibody-negative patients with recent-onset undifferentiated arthritis.

    Science.gov (United States)

    Hiura, Kazuya; Iwaki-Egawa, Sachiko; Kawashima, Toshiyuki; Fujisawa, Shin-Ichi; Takeda, Tsuyoshi; Komori, Hitoshi; Watanabe, Yasuhiro

    2013-09-01

    Anti-cyclic citrullinated peptide (anti-CCP) antibodies are well-established serological markers that show high sensitivity and specificity in early rheumatoid arthritis (RA) and are associated with bone erosions of RA. However, some patients subsequently progress to RA even if there is no presence of anti-CCP antibodies in an early stage. The aim of this study is to evaluate the diagnostic utility of matrix metalloproteinase-3 (MMP-3), high-sensitivity C-reactive protein (hsCRP) and IgM rheumatoid factor for predicting RA in anti-CCP-negative patients with recent-onset undifferentiated arthritis (UA). Baseline levels of those markers were measured at the entry of the study. A total of 99 patients with UA were included, among them 44 patients (44.4 %) had been classified as having RA by a skilled rheumatologist at some point during 1-year follow-up. Of these 99 patients, 34 patients (34.3 %) had anti-CCP antibodies and 65 patients (65.7 %) had no anti-CCP antibodies. Eleven patients who were anti-CCP-negative developed RA. We compared sensitivity, specificity, positive predictive value and negative predictive value of serum markers of these anti-CCP-negative RA patients. The combined usage of MMP-3 with hsCRP is relatively superior to other markers as predictors of RA.

  10. Results of immunohistochemistry diagnostics of breast cancer in the region of Grodno with consideration of the BRCA1 gene mutation in triple negative cancer

    OpenAIRE

    A. Yu. Krylov; M. G. Zubritsky; I. A. Kurstak; S. A. Lialikau; V. A. Basinski

    2017-01-01

    Background: The results of immunohistochemical (IHC) assessment in breast cancer may determine not only the outcome, but also the main directions of antitumor treatment.Aim: To study the results of IHC diagnosis of breast cancer in the Grodno region in 2010 to 2015, to determine the frequency of the BRCA1 gene mutations in triple-negative breast cancer.Materials and methods: 2008 cases of estrogen receptor and/or progesterone receptor positive and 2445 cases of HER2/neu expressing breast canc...

  11. Synchronous Detection of Hairy Cell Leukemia and HIV-Negative Kaposi’s Sarcoma of the Lymph Node: A Diagnostic Challenge and a Rare Coincidence

    Directory of Open Access Journals (Sweden)

    Seniz Ongoren Aydin

    2011-09-01

    Full Text Available Hairy cell leukemia (HCL is an uncommon chronic lymphoproliferative disorder and accounts for around 2% of all forms of leukemias. The association of HCL with other neoplasms, mainly non-Hodgkin’s lymphomas, is well known. However, the simultaneous diagnosis of HCL and Kaposi’s sarcoma is rare, with only few cases of such an association having been reported. We describe a 42-year-old male patient with a well characterized HCL and in whom HIV-negative Kaposi’s sarcoma of the lymph node was detected.

  12. Pure neuritic leprosy: Resolving diagnostic issues in acid fast bacilli (AFB)-negative nerve biopsies: A single centre experience from South India.

    Science.gov (United States)

    Hui, Monalisa; Uppin, Megha S; Challa, Sundaram; Meena, A K; Kaul, Subhash

    2015-01-01

    Demonstration of lepra bacilli is essential for definite or unequivocal diagnosis of pure neuritic leprosy (PNL) on nerve biopsy. However, nerves always do not show bacilli owing to the changes of previous therapy or due to low bacillary load in tuberculoid forms. In absence of granuloma or lepra bacilli, other morphologic changes in endoneurium and perineurium can be of help in making a probable diagnosis of PNL and treating the patient with multidrug therapy. Forty-six biopsies of PNL were retrospectively reviewed and histologic findings were compared with 25 biopsies of non leprosy neuropathies (NLN) including vasculitic neuropathy and chronic inflammatory demyelinating polyneuropathy (CIDP). The distribution of endoneurial infiltrate and fibrosis, perineurial thickening, and myelin abnormalities were compared between PNL and NLN biopsies and analyzed by Chi-square test. Out of 46 PNL casses, 24 (52.17 %) biopsies were negative for acid fast bacilli (AFB). In these cases, the features which favor a diagnosis of AFB-negative PNL were endoneurial infiltrate (51.1%), endoneurial fibrosis (54.2%), perineurial thickening (70.8%), and reduced number of myelinated nerve fibers (75%). Nerve biopsy is an efficient tool to diagnose PNL and differentiate it from other causes of NLN. In absence of AFB, the diagnosis of PNL is challenging. In this article, we have satisfactorily evaluated the various hisopthological features and found that endoneurial inflammation, dense fibrosis, and reduction in the number of myelinated nerve fibers are strong supportive indicators of PNL regardless of AFB positivity.

  13. Results of immunohistochemistry diagnostics of breast cancer in the region of Grodno with consideration of the BRCA1 gene mutation in triple negative cancer

    Directory of Open Access Journals (Sweden)

    A. Yu. Krylov

    2017-01-01

    Full Text Available Background: The results of immunohistochemical (IHC assessment in breast cancer may determine not only the outcome, but also the main directions of antitumor treatment.Aim: To study the results of IHC diagnosis of breast cancer in the Grodno region in 2010 to 2015, to determine the frequency of the BRCA1 gene mutations in triple-negative breast cancer.Materials and methods: 2008 cases of estrogen receptor and/or progesterone receptor positive and 2445 cases of HER2/neu expressing breast cancer were extracted from the database and IHC laboratory journals of the Grodno Regional Clinical Bureau for Pathological Anatomy. Standard DAKO kits (Denmark were used for IHC. Molecular genetic studies of DNA samples for the presence of the BRCA genes mutations were done by polymerase chain reaction in 449 women with breast cancer. BRCA1 mutation was assessed in 39 cases of triple-negative breast cancer.Results: HER2/neu overexpression (3+ was found in 25.5% (622/2445 of all breast cancer cases, whereas of estrogen receptor and progesterone receptor positive tumors in 50.05% (1105/2008 of cases. Triple negative breast cancer was diagnosed in 19.8% (398/2008 of cases, and the mean age of the patients at the diagnosis was 56.2 years. The BRCA1 gene mutations were identified in 5 of 39 (12.8% cases of triple negative breast cancer, which is significantly more often than in women with breast cancer without consideration of their hereditary predisposition (17/449, or 3.8%; χ2 = 4.87, p = 0.0274. Histological examination showed that among the tumors with the BRCA1 mutations, there were 3 cases with invasive ductal cancer (one G2 and two G3, one with medullary and one with undifferentiated G3 cancer. One patient had a metachronous bilateral lesion.Conclusion: In the region of Grodno, 50% of breast cancer patients would need hormonal therapy, 25% would need treatment with trastuzumab, and 20% with cytostatic agents. The

  14. Myocardial fatty acid imaging using iodine-123-BMIPP in patients with hypertensive intracranial hemorrhage

    International Nuclear Information System (INIS)

    Hashizume, Toshikazu; Sakai, Yasuhito; Hayashi, Yasushi

    2000-01-01

    An evaluation of myocardial fatty acid metabolism in hypertensive patients with major complication has not been previously established. To assess the myocardial fatty acid metabolism in hypertensive patients with intracranial hemorrhage (IH), we performed myocardial image using 123 I-15-p-iodophenyl-3-methyl pentadecanoic acid (BMIPP). Seventeen hypertensive patients with IH (HIH) and 27 hypertensive patients without IH (HT) were studied. A dose of 111 MBq of BMIPP was injected intravenously at rest, and a myocardial image was recorded 30 minutes after the injection. Myocardial perfusion image using Thallium-201 (Tl) was also performed within 2 weeks after BMIPP study. The regional myocardial uptakes of BMIPP and Tl were visually assessed in 17 segments with a four-point scoring system (0=absent to 3=normal uptake). Cardiac hypertrophy was evaluated by electrocardiogrpahy (ECG) and two-dimensional ultrasonic cardiography (UCG). Sum of uptake scores of Tl was similar in both groups (45.1±5.4 vs. 47.9±4.2), but that of BMIPP in HIH was lower than HT (35.9±7.9 vs 45.6±4.8, p<0.001). Evaluation of cardiac hypertrophy using ECG and UCG revealed no significant difference between two groups. HIH have much more eccentric hypertrophy in UCG study than HT (53% vs. 37%). These data suggest that hypertensive patients with intracranial hemorrhage have a more impaired myocardial fatty acid metabolism compared to the hypertensive patients with similar cardiac hypertrophy. BMIPP imaging might be useful to evaluate the severity of myocardial fatty acid metabolism in hypertensive patients. (author)

  15. Iodine-123-labeled pH shift brain-imaging agents

    International Nuclear Information System (INIS)

    Blau, M.; Kung, H.F.

    1985-01-01

    HIPDM is an 123 I-labeled agent with a distribution in brain reflecting regional perfusion. This compound is neutral and lipid soluble at blood pH and freely crosses the blood-brain barrier. At the lower pH in brain, it picks up a hydrogen ion and becomes positively charged. In this form the molecule is not lipid soluble and it is trapped in brain

  16. Design and biological properties of iodine-123 labeled β-methyl-branched fatty acids

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Goodman, M.M.

    1984-01-01

    The synthetic strategy, synthesis, preclinical evaluation and potential clinical applications of 3-methyl-branched radioiodinated iodophenyl- and iodovinyl-substituted fatty acids are reviewed for use as myocardial imaging agents. 50 references, 6 figures

  17. Iodine-123-interleukin-2 scintigraphy in metastatic hypernephroma : a pilot study

    NARCIS (Netherlands)

    Renard, V.; Staelens, L.; Signore, A.; Van Belle, S.; Dierckx, R. A.; De Wiele, C. Van

    2007-01-01

    Aim This pilot study reports on the uptake of I-123-interleukin 2 (IL-2) in metastatic renal cell carcinoma (MRCC) patients and its relationship to prognostic factors of response or failure of MRCC to cytokines treatment. Methods. Nine consecutive patients with MRCC underwent an I-123-IL-2 scan (6

  18. Design and biological properties of iodine-123 labeled. beta. -methyl-branched fatty acids

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Goodman, M.M.

    1984-01-01

    The synthetic strategy, synthesis, preclinical evaluation and potential clinical applications of 3-methyl-branched radioiodinated iodophenyl- and iodovinyl-substituted fatty acids are reviewed for use as myocardial imaging agents. 50 references, 6 figures. (ACR)

  19. Application of iodine-123-labeled isopropylamphetamine imaging to the study of dementia

    International Nuclear Information System (INIS)

    Sharp, P.; Gemmell, H.; Cherryman, G.; Besson, J.; Crawford, J.; Smith, F.

    1986-01-01

    Forty-seven patients diagnosed as clinically demented were imaged with 123I isopropylamphetamine (IMP). All of these patients also had a nuclear magnetic resonance (NMR) study. In those patients diagnosed as having senile dementia of the Alzheimer type a bilateral reduction in IMP uptake in the temporo-parieto-occipital region was always seen. The NMR appearances were normal in 64% of these sites. The IMP images of patients with multi-infarct dementia varied from normal to marked focal deficits. There was, however, a much closer agreement between the abnormalities seen on the IMP and NMR images. In alcoholic dementia no focal areas of reduced IMP uptake were seen, although the uptake was generally irregular. In both Korsakoff's psychosis and Huntington's chorea the IMP uptake pattern and the NMR study were normal

  20. The production of iodine-123 on the Harwell variable energy cyclotron

    International Nuclear Information System (INIS)

    Cuninghame, J.G.; Hill, J.I.S.; Nichols, A.L.; Taylor, N.K.

    1978-01-01

    123 I has often been called the isotope of choice for dynamic body function studies in nuclear medicine. There has therefore, been a keen interest in the possibility of regular supply of high purity 123 I produced by the Harwell Variable Energy Cyclotron (VEC) and Synchrocyclotron (SC). This report describes a three year research and development programme on the VEC which has resulted in a method for the safe and reliable large scale production of 123 I by irradiation of di-iodomethane with 58 MeV protons. The quality of the product, and the medical trials which have been carried out with it, are also discussed. The processing and handling of the hundreds of millicuries produced during a run presents serious handling problems. These have been solved and the methods and equipment developed are described. (author)

  1. Diagnosis of Alzheimer's disease and multiple infarct dementia by tomographic imaging of iodine-123 IMP

    International Nuclear Information System (INIS)

    Cohen, M.B.; Graham, L.S.; Lake, R.

    1986-01-01

    Tomographic imaging of the brain was performed using a rotating slant hole collimator and [ 123 I]N-isopropyl p-iodoamphetamine (IMP) in normal subjects (n = 6) and patients with either Alzheimer's disease (n = 5) or multiple infarct dementia (n = 3). Four blinded observers were asked to make a diagnosis from the images. Normal subjects and patients with multiple infarct dementia were correctly identified. Alzheimer's disease was diagnosed in three of the five patients with this disease. One patient with early Alzheimer's disease was classified as normal by two of the four observers. Another patient with Alzheimer's disease had an asymmetric distribution of IMP and was incorrectly diagnosed as multiple infarct dementia by all four observers. Limited angle tomography of the cerebral distribution of 123 I appears to be a useful technique for the evaluation of demented patients

  2. Objective, planimetry-based assessment of megakaryocyte histological pictures in Philadelphia-chromosome-negative chronic myeloproliferative disorders: a perspective for a valuable adjunct diagnostic tool.

    Science.gov (United States)

    Rudzki, Zbigniew; Kawa, Rafał; Okoñ, Krzysztof; Szczygieł, Ewa; Stachura, Jerzy

    2006-01-01

    Philadelphia-chromosome-negative chronic myeloproliferative disorders (Ph- CMPDs)--essential thrombocythemia (ET), chronic idiopathic myelofibrosis (CIMF), and polycythemia vera (PV)--may show clinical and morphological similarities, particularly at the early stages. The differential diagnosis of Ph- CMPDs is important due to their different treatment and prognosis. Cytological features of megakaryocytes are considered valuable in this differentiation. To establish an objective measure of megakaryocyte dysplasia in Ph- CMPDs, we performed computer-assisted morphometry of more than 4,000 cells from 20 cases of ET, 10 of CIMF, 10 of PV, and 10 controls. Megakaryocyte sets from three Ph- CMPDs differed significantly in respect to many planimetric parameters, but not a single shape or size parameter could have been used as a discriminative tool between the entities. However, the discriminant function analysis with the simultaneous assessment of 12 planimetric variables allowed for a proper classification of 20 of 20 ET, 10 of 10 PV, and 9 of 10 CIMF cases based solely on the morphometric features of megakaryocytes. Additionally, we identified certain new patterns of megakaryocytes specific for ET, PV, and CIMF, which, although not dominating in one Ph- CMPD, are unlikely to occur in two others. Objective measurements of megakaryocyte sizes and shapes may assist the diagnosis of Ph- CMPDs.

  3. Diagnostic performance of myocardial innervation imaging using MIBG scintigraphy in differential diagnosis between dementia with lewy bodies and other dementias: a systematic review and a meta-analysis.

    Science.gov (United States)

    Treglia, Giorgio; Cason, Ernesto

    2012-04-01

    This study was designed to review the diagnostic performance of myocardial innervation imaging using iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy in differential diagnosis between dementia with Lewy bodies (DLB) and other dementias. A comprehensive computer literature search of studies published through May 2010 regarding MIBG scintigraphy in patients with DLB was performed in PubMed/MEDLINE and Embase databases. Only studies in which MIBG scintigraphy was performed for differential diagnosis between DLB and other dementias were selected. Pooled sensitivity and specificity of MIBG scintigraphy were presented with a 95% confidence interval (CI). The area under the ROC curve was calculated to measure the accuracy of MIBG scintigraphy in differential diagnosis between Lewy body diseases and other dementias. Ultimately, we identified 8 studies comprising a total of 346 patients with dementia (152 patients with DLB and 194 patients with other dementias). The pooled sensitivity of MIBG scintigraphy in detection of DLB was 98% (95% CI, 94-100%); the pooled specificity of MIBG scintigraphy in differential diagnosis between DLB and other dementias was 94% (95% CI, 90-97%). The area under the ROC curve was .99. Myocardial innervation imaging with MIBG scintigraphy demonstrated high pooled sensitivity and specificity in patients with suspected DLB. MIBG scintigraphy is an accurate test for differential diagnosis between DLB and other dementias. Copyright © 2010 by the American Society of Neuroimaging.

  4. A comparative analysis of molecular genetic and conventional cytogenetic detection of diagnostically important translocations in more than 400 cases of acute leukemia, highlighting the frequency of false-negative conventional cytogenetics.

    Science.gov (United States)

    King, Rebecca L; Naghashpour, Mojdeh; Watt, Christopher D; Morrissette, Jennifer J D; Bagg, Adam

    2011-06-01

    In this study, we correlated the results of concurrent molecular and cytogenetic detection of entity-defining translocations in adults with acute leukemia to determine the frequency of cryptic translocations missed by conventional cytogenetics (CC) and of recurrent, prognostically relevant translocations not detectable by multiplex reverse transcriptase-polymerase chain reaction (MRP). During a 5.5-year period, 442 diagnostic acute leukemia specimens were submitted for MRP-based detection of 7 common recurrent translocations: t(8;21), t(15;17), inv(16), t(9;22), t(12;21), t(4;11), and t(1;19), with a detection rate of 15.2% (67/442). CC was performed in 330 (74.7%) of 442 cases. In 7 of these 330 cases, CC missed the translocation detected by MRP. In 50 additional cases, CC revealed 1 of the MRP-detectable translocations (all were also MRP positive), yielding a false-negative rate of 12% (7/57) for the CC assay. The remaining 140 of 190 cases with clonal cytogenetic changes harbored abnormalities that were not targeted by the MRP assay, including 8 that define specific acute myeloid leukemia entities. This study revealed the frequent occurrence of false-negative, entity-defining CC analysis and highlighted the complementary nature of MRP and CC approaches in detecting genetic abnormalities in acute leukemia.

  5. Periodontal diagnostics.

    Science.gov (United States)

    Kinane, D F

    2000-10-01

    Periodontitis affects a subset of the population and our current thinking is that progression of periodontal disease may be either continuous or cyclical (burst hypothesis). These features make screening and diagnostic tools desirable in the management of this disease. Although many potential markers exist, several difficulties hamper our ability to declare them diagnostic tests with proven utility. The 'gold standard' for active periodontal disease is not available and inflammation due to gingivally confined lesions (gingivitis) and periodontal inflammation which results in attachment loss is a potential confounder of any test based on assessing the host response elements of the disease. The current absence of proof for the progression of periodontal disease i.e., whether or not the burst hypothesis is correct, is a further problem. Although much is written about the need for markers of current or future disease which will prevent us from overtreating pockets, the time, effort and cost involved in testing these sites has to be balanced against the relative ease and speed of routine therapy such as root planing. In addition, we are still some way from the development and validation of reliable host or microbial testing methods. In terms of screening tests for diseases such as the early-onset forms of periodontitis, the research and development on diagnostic tools involving genetic polymorphisms, specific genes, systemic antibodies or leucocyte cell surface markers of the patients, may become a clinical reality in time. One could envisage chairside tests using blood from thumb pricks being capable of determining a young individual's risk of developing disease at a later age, and thus the need for a timely prevention programme. Before applying any test we should reconsider what treatment planning effects a positive or negative result will have, and any test which does not influence the treatment plan is redundant. Whether periodontal diagnostic tests will be

  6. When negation is not negation

    OpenAIRE

    Milicevic, Nataša

    2008-01-01

    In this paper I will discuss the formation of different types of yes/no questions in Serbian (examples in (1)), focusing on the syntactically and semantically puzzling example (1d), which involves the negative auxiliary inversion. Although there is a negative marker on the fronted auxiliary, the construction does not involve sentential negation. This coincides with the fact that the negative quantifying NPIs cannot be licensed. The question formation and sentential negation have similar synta...

  7. Mitigation diagnostics

    International Nuclear Information System (INIS)

    Hall, S.T.

    1990-01-01

    This paper reports that experience in the remediation of schools and other large buildings has shown the importance of the effects of both the location of geologic sources and HVAC-induced distribution of indoor radon. In general, elevated radon in areas of schools with evenly distributed HVAC pressures are correlated with maximum soil radon emanations. However, strong or unequal HVAC effects can redistribute indoor radon to areas away from the direct source. Effective remediation required a complete understanding of both contributions. In some schools, highest indoor radon levels were located near large return ducts and were attributed to proximity to negative HVAC pressure. Successful sub-slab depressurization systems were installed, however, in rooms with lower indoor but greatest sub-slab radon levels, closest to the source. This shows the inadequacy of using indoor radon levels alone as a basis for remediation. Wings of two other schools with radon problems have equivalent window fan coil units in rooms of equal size and no central HVAC system. Highest indoor radon levels correlated well with highest sub-slab radon levels due to the equivalent effects of the window units. Diagnostic tests in other schools have revealed: blockwall radon transport to upper floors; high blockwall radon adjacent to sub-slab sources; and elevated indoor radon over crawlspace being drawn upward by HVAC-induced negative pressure, determined from indoor to outdoor micromanometer measurements

  8. Negative ... concord?

    NARCIS (Netherlands)

    Giannakidou, A

    The main claim of this paper is that a general theory of negative concord (NC) should allow for the possibility of NC involving scoping of a universal quantifier above negation. I propose that Greek NC instantiates this option. Greek n-words will be analyzed as polarity sensitive universal

  9. [Cytology in uropathological diagnostics].

    Science.gov (United States)

    Gaisa, N T; Lindemann-Docter, K

    2015-11-01

    Cytology in uropathological diagnostics is mainly performed for oncological purposes. The assessment of malignancy by urothelial cell morphology is therefore decisive; however, cytology is only sensitive enough to detect high-grade tumor cells and the different low-grade tumors cannot be reliably diagnosed. Thus, the four-tier classification system of cytological findings (i.e. negative, atypical cells but significance uncertain, suspicious and positive) refers to high-grade tumor cells only. Furthermore, for valid cytological diagnostics not only the cytological specimen but also clinical information on cystoscopy findings and, if applicable, a biopsy should be evaluated together. In difficult differential diagnostic settings, e.g. differentiation between reactive versus neoplastic atypia or difficult to access lesions in the upper urinary tract, additional fluorescence in situ hybridization of cytological preparations might be helpful. At the moment there are no indications for further immunocytology or additional biomarker tests.

  10. Diagnostic laparoscopy

    Science.gov (United States)

    ... cavity. These complications could lead to immediate open surgery ( laparotomy ). Diagnostic laparoscopy may not be possible if you have a swollen bowel, fluid in the abdomen (ascites), or you have had a past surgery.

  11. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    . Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...... of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently...

  12. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    NARCIS (Netherlands)

    Booij, J.; Korn, P.; Linszen, D. H.; van Royen, E. A.

    1997-01-01

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET)

  13. Dynamic SPECT with technetium-99m HM-PAO in meningiomas--a comparison with iodine-123 IMP

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S.; Kinoshita, K.; Jinnouchi, S.; Hoshi, H.; Watanabe, K.

    1989-06-01

    Technetium-99m hexamethylpropyleneamine oxime ((/sup 99m/Tc)HM-PAO) has recently been introduced as an alternative to N-isopropyl-p-/sup 123/I-iodoamphetamine ((/sup 123/I)IMP) for measurement of regional cerebral blood flow. This study compares dynamic SPECT studies using the two tracers in seven patients with meningiomas. Regions of interest were placed over the lesion and contralateral homologous presumed normal area. The counting-rate ratio for the lesion to the contralateral homologous area (L/N ratio) was then calculated in the first image. L/N ratios of ((/sup 99m/Tc)HM-PAO) single photon emission computed tomography (SPECT) were lower than those of ((/sup 123/I)IMP) SPECT, particularly in hypervascular meningiomas. Furthermore, time-activity curves showed that the washout of ((/sup 99m/Tc)HM-PAO) in the tumors was very slow or incomplete, preventing an accurate assessment of vascularity of meningiomas with ((/sup 99m/Tc)HM-PAO), as is generally possible with ((/sup 123/I)IMP).

  14. Evaluation of long-term prognosis in patients with heart failure. Is cardiac imaging with iodine-123 metaiodobenzylguanidine useful?

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    1998-01-01

    The effect of cardiac sympathetic activity on long-term prognosis in patients with heart failure was evaluated by cardiac imaging with 123 I-MIBG in 46 patients admitted for the first episode of heart failure. Cardiac imaging was performed with 123 I-MIBG and 201 Tl at rest on separate days before discharge. Using whole body imaging, the ratio of cardiac uptake of the isotope to total injected dose was calculated (percentage uptake). The cardiac uptake ratio of 123 I-MIBG (percentage uptake of 123 I-MIBG divided by percentage uptake of 201 Tl) and percentage washout of 123 I-MIBG from the heart over 3 hours were calculated as scintigraphic parameters. Cardiac events were defined as cardiac death or deterioration of heart failure requiring readmission. Scintigraphic parameters, clinical parameters, left ventricular function obtained by echocardiography and neurohumoral parameters were compared between the event group and event-free group. During the follow-up period, cardiac events developed in 14 patients (30%). Univariate analysis showed uptake ratio and washout rate of 123 I-MIBG, percentage uptake of 201 Tl, New York Heart Association class at discharge, fractional shortening of the left ventricle, serum norepinephrine and atrial natriuretic peptide levels differed significantly between the two groups. Cox proportional-hazard analysis showed that the uptake ratio was an independent predictor of cardiac events. When a cut-off point in the uptake ratio equal to or less than 0.50 and age equal to or more than 65 years old were included in the Cox proportional-hazard analysis instead of actual numbers, relative risks of cardiac events by each index were 31.2 and 4.2, respectively. These data suggest that cardiac uptake of 123 I-MIBG is a strong and independent predictor of long-term prognosis in patients with heart failure. (K.H.)

  15. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  16. Fungal diagnostics.

    Science.gov (United States)

    Kozel, Thomas R; Wickes, Brian

    2014-04-01

    Early diagnosis of fungal infection is critical to effective treatment. There are many impediments to diagnosis such as a diminishing number of clinical mycologists, cost, time to result, and requirements for sensitivity and specificity. In addition, fungal diagnostics must meet the contrasting needs presented by the increasing diversity of fungi found in association with the use of immunosuppressive agents in countries with high levels of medical care and the need for diagnostics in resource-limited countries where large numbers of opportunistic infections occur in patients with AIDS. Traditional approaches to diagnosis include direct microscopic examination of clinical samples, histopathology, culture, and serology. Emerging technologies include molecular diagnostics and antigen detection in clinical samples. Innovative new technologies that use molecular and immunoassay platforms have the potential to meet the needs of both resource-rich and resource-limited clinical environments.

  17. Diagnostic formulation

    OpenAIRE

    Kuruvilla, K.; Kuruvilla, Anju

    2010-01-01

    Writing a ?Diagnostic Formulation? is a skill expected of candidates in the post-graduate examinations in psychiatry in most universities in India. However there is ambiguity regarding what the term means and how it should be written. This article is an attempt to provide some guidelines on this topic.

  18. [Diagnostic laparoscopy in acute abdomen].

    Science.gov (United States)

    Keller, R; Kleemann, M; Hildebrand, P; Roblick, U J; Bruch, H-P

    2006-11-01

    Acute abdomen is not a disease in itself but a description of a complex of symptoms combined with severe abdominal pain developed within a time frame of less than 24 h. All strategies for the management of acute abdomen underline the need for an interdisciplinary approach to diagnosis and therapy. This requires focused and intelligent use of efficient diagnostic procedures. Diagnostic laparoscopy may be a key to solving the diagnostic dilemma of unspecific acute abdomen. Furthermore, it allows not only direct inspection of the abdominal cavity but also surgical intervention, if needed. In particular the rate of negative laparotomies can be reduced.

  19. Gene panel testing of 5589 BRCA1/2-negative index patients with breast cancer in a routine diagnostic setting: results of the German Consortium for Hereditary Breast and Ovarian Cancer.

    Science.gov (United States)

    Hauke, Jan; Horvath, Judit; Groß, Eva; Gehrig, Andrea; Honisch, Ellen; Hackmann, Karl; Schmidt, Gunnar; Arnold, Norbert; Faust, Ulrike; Sutter, Christian; Hentschel, Julia; Wang-Gohrke, Shan; Smogavec, Mateja; Weber, Bernhard H F; Weber-Lassalle, Nana; Weber-Lassalle, Konstantin; Borde, Julika; Ernst, Corinna; Altmüller, Janine; Volk, Alexander E; Thiele, Holger; Hübbel, Verena; Nürnberg, Peter; Keupp, Katharina; Versmold, Beatrix; Pohl, Esther; Kubisch, Christian; Grill, Sabine; Paul, Victoria; Herold, Natalie; Lichey, Nadine; Rhiem, Kerstin; Ditsch, Nina; Ruckert, Christian; Wappenschmidt, Barbara; Auber, Bernd; Rump, Andreas; Niederacher, Dieter; Haaf, Thomas; Ramser, Juliane; Dworniczak, Bernd; Engel, Christoph; Meindl, Alfons; Schmutzler, Rita K; Hahnen, Eric

    2018-03-09

    The prevalence of germ line mutations in non-BRCA1/2 genes associated with hereditary breast cancer (BC) is low, and the role of some of these genes in BC predisposition and pathogenesis is conflicting. In this study, 5589 consecutive BC index patients negative for pathogenic BRCA1/2 mutations and 2189 female controls were screened for germ line mutations in eight cancer predisposition genes (ATM, CDH1, CHEK2, NBN, PALB2, RAD51C, RAD51D, and TP53). All patients met the inclusion criteria of the German Consortium for Hereditary Breast and Ovarian Cancer for germ line testing. The highest mutation prevalence was observed in the CHEK2 gene (2.5%), followed by ATM (1.5%) and PALB2 (1.2%). The mutation prevalence in each of the remaining genes was 0.3% or lower. Using Exome Aggregation Consortium control data, we confirm significant associations of heterozygous germ line mutations with BC for ATM (OR: 3.63, 95%CI: 2.67-4.94), CDH1 (OR: 17.04, 95%CI: 3.54-82), CHEK2 (OR: 2.93, 95%CI: 2.29-3.75), PALB2 (OR: 9.53, 95%CI: 6.25-14.51), and TP53 (OR: 7.30, 95%CI: 1.22-43.68). NBN germ line mutations were not significantly associated with BC risk (OR:1.39, 95%CI: 0.73-2.64). Due to their low mutation prevalence, the RAD51C and RAD51D genes require further investigation. Compared with control datasets, predicted damaging rare missense variants were significantly more prevalent in CHEK2 and TP53 in BC index patients. Compared with the overall sample, only TP53 mutation carriers show a significantly younger age at first BC diagnosis. We demonstrate a significant association of deleterious variants in the CHEK2, PALB2, and TP53 genes with bilateral BC. Both, ATM and CHEK2, were negatively associated with triple-negative breast cancer (TNBC) and estrogen receptor (ER)-negative tumor phenotypes. A particularly high CHEK2 mutation prevalence (5.2%) was observed in patients with human epidermal growth factor receptor 2 (HER2)-positive tumors. © 2018 The Authors. Cancer Medicine

  20. Ambient diagnostics

    CERN Document Server

    Cai, Yang

    2014-01-01

    Part I. FundamentalsIntroductionWhat is Ambient Diagnostics?Diagnostic ModelsMultimedia IntelligenceCrowd SourcingSoft SensorsScience of SimplicityPersonal DiagnosesBasic AlgorithmsBasic ToolsSummaryProblemsTransformationEarly Discoveries of Heartbeat PatternsTransforms, Features, and AttributesSequential FeaturesSpatiotemporal FeaturesShape FeaturesImagery FeaturesFrequency Domain FeaturesMulti-Resolution FeaturesSummaryProblemsPattern RecognitionSimilarities and DistancesClustering MethodsClassification MethodsClassifier Accuracy MeasuresSummaryProblemsPart II. Multimedia IntelligenceSound RecognitionMicrophone AppsModern Acoustic Transducers (Microphones)Frequency Response CharacteristicsDigital Audio File FormatsHeart Sound SensingLung Sound SensingSnore MeterSpectrogram (STFT)Ambient Sound AnalysisSound RecognitionRecognizing Asthma SoundPeak ShiftFeature CompressionRegroupingNoise IssuesFuture ApplicationsSummaryProblemsColor SensorsColor SensingHuman Color VisionColor SensorsColor Matching ExperimentsC...

  1. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  2. Coagulase-Negative Staphylococci

    Science.gov (United States)

    Heilmann, Christine; Peters, Georg

    2014-01-01

    SUMMARY The definition of the heterogeneous group of coagulase-negative staphylococci (CoNS) is still based on diagnostic procedures that fulfill the clinical need to differentiate between Staphylococcus aureus and those staphylococci classified historically as being less or nonpathogenic. Due to patient- and procedure-related changes, CoNS now represent one of the major nosocomial pathogens, with S. epidermidis and S. haemolyticus being the most significant species. They account substantially for foreign body-related infections and infections in preterm newborns. While S. saprophyticus has been associated with acute urethritis, S. lugdunensis has a unique status, in some aspects resembling S. aureus in causing infectious endocarditis. In addition to CoNS found as food-associated saprophytes, many other CoNS species colonize the skin and mucous membranes of humans and animals and are less frequently involved in clinically manifested infections. This blurred gradation in terms of pathogenicity is reflected by species- and strain-specific virulence factors and the development of different host-defending strategies. Clearly, CoNS possess fewer virulence properties than S. aureus, with a respectively different disease spectrum. In this regard, host susceptibility is much more important. Therapeutically, CoNS are challenging due to the large proportion of methicillin-resistant strains and increasing numbers of isolates with less susceptibility to glycopeptides. PMID:25278577

  3. [Diagnostic significance of multiparametric MRI combined with US-fusion guided biopsy of the prostate in patients with increased PSA levels and negative standard biopsy results to detect significant prostate cancer - Correlation with the Gleason score. Korrelation mit dem Gleason Score].

    Science.gov (United States)

    Hoffmann, Manuela; Hoffmann, Manuela A; Wieler, Helmut J; Jakobs, Frank M; Taymoorian, Kasra; Gerhards, Arnd; Miederer, Matthias; Schreckenberger, Mathias

    2017-08-14

    To increase diagnostic precision and to reduce overtreatment of low-risk malignant disease, multiparametric MRI (mpMRI) combined with ultrasound (US) fusion guided biopsy of the prostate were performed. In 99 male patients with increased PSA plasma levels and previous negative standard biopsy procedures, mpMRI was carried out followed by US fusion guided perineal biopsy. PI-RADS-Data (PS) of mpMRI and histopathological Gleason score (GS) were categorized and statistically compared. Lesions in 72/99 (73 %) of patients were determined to be suspect of malignancy, based on a PS 4 or 5. In 33/99 (33 %) of patients, malignancy could not be confirmed by histopathology. With regard to the remaining 66 patients with previous negative biopsy results, 42 (64 %) were diagnosed with a low-grade carcinoma (GS 6, 7a) and 24 (36 %) with a high-grade carcinoma (GS ≥ 7b). The proportion of corresponding results in mpMRI (PS 4-5) when a high-grade carcinoma had been detected, was 21/24 (88 %), which related to a sensitivity of 88 % and a negative predictive value (NPV) of 85 % (p = 0,002). In addition, 35 of 42 patients (83%), graded PS 4-5 in mpMRI, were diagnosed with low-grade carcinoma-positive (p < 0,001). Sensitivity to differentiation between low- and high-grade carcinomas (GS ≤ 7a vs. ≥ 7b) by means of PS was 88 % with a NPV of 70 % (p = 0,74). Our results suggest that mpMRI combined with US-fusion guided biopsy is able to detect considerably higher rates of clinically relevant prostate malignancies compared to conventional diagnostic procedures. However, no statistical significance could be shown regarding the differentiation between high- and low-grade carcinomas. It is hoped that the hybrid methods PSMA-PET/CT or PSMA-PET/MRI will lead to the next optimization step in the differentiation between high- and low-grade carcinomas which so far has been unsatisfactory.

  4. Diagnostic value of glypican-3 in alpha fetoprotein negative ...

    African Journals Online (AJOL)

    EB

    2013-09-03

    Sep 3, 2013 ... Background: The prognosis of patients with hepatocellular carcinoma(HCC) is generally very poor with a 5-year survival rate of less than 15% since most of ... antigen (CEA), CD34, alpha fetoprotein (AFP) were usually used to .... and a number of immunomarkers have been widely utilized to facilitate the ...

  5. Quality and diagnostic perspectives in laboratory diagnostics

    OpenAIRE

    Müller, Mathias M.

    2010-01-01

    Laboratory diagnostics is a medical discipline playing an important part in patient management. In laboratory medicine meaningful, accurate and precise routine measurements are essential for diagnosis, risk assessment, treatment and follow-up of patients. The contribution of the diagnostic laboratory in the overall diagnostic process is app. 40-60%, depending on the kind of disease status investigated. The diagnostic laboratory uses nowadays more than 1.000 different tests mostly provided by ...

  6. What Is Diagnostic Testing?

    Science.gov (United States)

    ... you want to learn. Search form Search Diagnostic testing You are here Home Testing & Services Testing for ... help you make the decision. What Is Diagnostic Testing? Diagnostic genetic testing can usually work out if ...

  7. Image diagnostic of colonic diseases - controversial questions

    International Nuclear Information System (INIS)

    Pomakov, P.; Rizov, A.; Stancheva, I.

    2013-01-01

    In the system of colonic diseases' diagnostic algorithm, fibrocolonoscopy (FCS) is defined as 'Golden Standard'. By this reason some X-ray diagnostic methods - irrigography, etc. are currently not being used in a number of health institutions. The aim of this study is a comparative analysis of FCS and irrigography diagnostic efficacy in various colonic diseases. For 10-years period, in cooperation with a gastroenterologist-gastroscopist, 2151 patients with various colonic diseases were evaluated by FCS and irrigography with pharmaco-diagnostics/when necessary. Advantage of FCS was established in diagnosing diseases with patho-morfologic changes on the inner surface of the colon - benign and malignant neoplastic processes, chronic inflammatory diseases, etc. At the same time functional changes - irritated colon syndrome, changes in defecation act, etc., are not an object of diagnosis through FCS. Correction in colonic diseases diagnostic algorithm is necessary. FCS should be mandatory. If result is negative - irrigography with pharmaco-diagnostics should be done. (authors)

  8. Negating the Verum

    DEFF Research Database (Denmark)

    Ørsnes, Bjarne

    2012-01-01

    an (aboutness-)topic. The negation of a verum predicate explains why preposed negation—like other constructions with verum-focus—fails to license strong negative polarity items and fails to rule out positive ones. The lack of a topic explains why preposed negation is preferred with non-referential subjects...

  9. Sentential Negation in English

    Science.gov (United States)

    Mowarin, Macaulay

    2009-01-01

    This paper undertakes a detailed analysis of sentential negation in the English language with Chomsky's Government-Binding theory of Transformational Grammar as theoretical model. It distinguishes between constituent and sentential negation in English. The essay identifies the exact position of Negation phrase in an English clause structure. It…

  10. Diagnostic accuracy of organ electrodermal diagnostics

    African Journals Online (AJOL)

    ll Diagnostic methods based upon measurements of electrical potential, resistance and impedance of these zones have been proposed; however, their diagnostic accuracy has not been proven and reproducibility has not been consistent. Some of these methods utilise specific bio-electrical properties of acupuncture points.

  11. Negative ion sources

    International Nuclear Information System (INIS)

    Ishikawa, Junzo; Takagi, Toshinori

    1983-01-01

    Negative ion sources have been originally developed at the request of tandem electrostatic accelerators, and hundreds of nA to several μA negative ion current has been obtained so far for various elements. Recently, the development of large current hydrogen negative ion sources has been demanded from the standpoint of the heating by neutral particle beam injection in nuclear fusion reactors. On the other hand, the physical properties of negative ions are interesting in the thin film formation using ions. Anyway, it is the present status that the mechanism of negative ion action has not been so fully investigated as positive ions because the history of negative ion sources is short. In this report, the many mechanisms about the generation of negative ions proposed so far are described about negative ion generating mechanism, negative ion source plasma, and negative ion generation on metal surfaces. As a result, negative ion sources are roughly divided into two schemes, plasma extraction and secondary ion extraction, and the former is further classified into the PIG ion source and its variation and Duoplasmatron and its variation; while the latter into reflecting and sputtering types. In the second half of the report, the practical negative ion sources of each scheme are described. If the mechanism of negative ion generation will be investigated more in detail and the development will be continued under the unified know-how as negative ion sources in future, the development of negative ion sources with which large current can be obtained for any element is expected. (Wakatsuki, Y.)

  12. Polemic and Descriptive Negations

    DEFF Research Database (Denmark)

    Horslund, Camilla Søballe

    2011-01-01

    as such may be more or less central to the meaning of the utterance. The present paper investigates the role of morphosyntactic and prosodic prominence as well as register and social setting on the interpretation of negations. It seems plausible to expect that if the negation as such is central to the meaning...... of the utterance (as in polemic negations), the negation will be articulated prominently in order to emphasise this importance. Likewise, if the negation is not central to the meaning of the utterance, it should not be articulated prominently. Moreover, it is plausible to expect descriptive negations to be more...... common in certain social context or genres, while polemic negations are more likely to come up in other genres and social settings. Previous studies have shown a relation between articulatory prominence and register, which may further inform the analysis. Hence, the paper investigates how articulatory...

  13. Thioaptamer Diagnostic System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) will develop a diagnostic system in response to SBIR Topic X10.01 Reusable Diagnostic Lab Technology that will simultaneously detect and...

  14. Negative bone scintigraphy and diffuse osteoblastic breast carcinoma metastases

    International Nuclear Information System (INIS)

    Rousseau, C.; Resche, I.; Chatal, J.F.; Campone, M.; Fumoleau, P.; Cussac, A.; Meingan, P.

    2001-01-01

    The authors report a case of metastatic breast carcinoma with a negative bone scan in spite of densely sclerotic metastases on radiography. The literature is reviewed with regard to the subject of such negative bone scan in this clinical situation and the alternative possibilities to document the diagnostic of breast bone metastases are discussed. The 'normal' scintigraphic pattern is not clearly explained. (authors)

  15. Negative Ion Density Fronts

    International Nuclear Information System (INIS)

    Igor Kaganovich

    2000-01-01

    Negative ions tend to stratify in electronegative plasmas with hot electrons (electron temperature Te much larger than ion temperature Ti, Te > Ti ). The boundary separating a plasma containing negative ions, and a plasma, without negative ions, is usually thin, so that the negative ion density falls rapidly to zero-forming a negative ion density front. We review theoretical, experimental and numerical results giving the spatio-temporal evolution of negative ion density fronts during plasma ignition, the steady state, and extinction (afterglow). During plasma ignition, negative ion fronts are the result of the break of smooth plasma density profiles during nonlinear convection. In a steady-state plasma, the fronts are boundary layers with steepening of ion density profiles due to nonlinear convection also. But during plasma extinction, the ion fronts are of a completely different nature. Negative ions diffuse freely in the plasma core (no convection), whereas the negative ion front propagates towards the chamber walls with a nearly constant velocity. The concept of fronts turns out to be very effective in analysis of plasma density profile evolution in strongly non-isothermal plasmas

  16. Nonculture Diagnostics in Fungal Disease.

    Science.gov (United States)

    Powers-Fletcher, Margaret V; Hanson, Kimberly E

    2016-03-01

    Fungal diagnostics that utilize antibody, antigen or nucleic acid detection offer several advantages that supplement traditional culture-based methods. As a group, nonculture assays can help identify patients with invasive fungal infection (IFI) sooner than is possible with culture, are often more sensitive, and can be used to guide early interventions. Challenges associated with these techniques include the possibility for contamination or cross-reactivity as well as the potential for false negative tests. This review summarized the test characteristics and clinical utility of nonculture-based laboratory methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Diagnostic imaging of the pancreas

    International Nuclear Information System (INIS)

    Araki, Tsutomu; Itai, Yuji

    1981-01-01

    Diagnostic imaging of the pancreas, ultrasonography (US), computed tomography (CT), radionuclide (RN) scintigraphy, angiography, and endoscopic retrograde pancreaticography (ERP). First three noninvasive methods, were the most effective to diagnose psudo-cyst or cystoadenoma. Especially, CT gives the clear image of inflammation and shows pancreatic stones and calcification, with high sensitivity. As for pancreatic carcinomas there was no noninvasive methods to apply at an early stage. In order to diagnose the cancer the combination of angiography and ERP was preferable. The problem was how to select the candidates for the investigation of combined method out of the patients with negative CT or US. (Tsunoda, M.)

  18. Optoelectronic tweezers for medical diagnostics

    Science.gov (United States)

    Kremer, Clemens; Neale, Steven; Menachery, Anoop; Barrett, Mike; Cooper, Jonathan M.

    2012-01-01

    Optoelectronic tweezers (OET) allows the spatial patterning of electric fields through selected illumination of a photoconductive surface. This enables the manipulation of micro particles and cells by creating non-uniform electrical fields that then produce dielectrophoretic (DEP) forces. The DEP responses of cells differ and can produce negative or positive (repelled or attracted to areas of high electric field) forces. Therefore OET can be used to manipulate individual cells and separate different cell types from each other. Thus OET has many applications for medical diagnostics, demonstrated here with work towards diagnosing Human African Trypanosomiasis, also known as sleeping sickness.

  19. Negative thermal expansion materials

    International Nuclear Information System (INIS)

    Evans, J.S.O.

    1997-01-01

    The recent discovery of negative thermal expansion over an unprecedented temperature range in ZrW 2 O 8 (which contracts continuously on warming from below 2 K to above 1000 K) has stimulated considerable interest in this unusual phenomenon. Negative and low thermal expansion materials have a number of important potential uses in ceramic, optical and electronic applications. We have now found negative thermal expansion in a large new family of materials with the general formula A 2 (MO 4 ) 3 . Chemical substitution dramatically influences the thermal expansion properties of these materials allowing the production of ceramics with negative, positive or zero coefficients of thermal expansion, with the potential to control other important materials properties such as refractive index and dielectric constant. The mechanism of negative thermal expansion and the phase transitions exhibited by this important new class of low-expansion materials will be discussed. (orig.)

  20. Diagnostic Utility of Alpha-fetoprotein and Des-gamma ...

    African Journals Online (AJOL)

    2018-02-07

    ] High DCP levels also reflect .... using the multiple logistic regression models. P < 0.05 was considered statistically significant. .... that C-reactive protein has significant diagnostic power in AFP-negative, HBV-related HCC.[23].

  1. Negative thermal expansion

    International Nuclear Information System (INIS)

    Barrera, G D; Bruno, J A O; Barron, T H K; Allan, N L

    2005-01-01

    There has been substantial renewed interest in negative thermal expansion following the discovery that cubic ZrW 2 O 8 contracts over a temperature range in excess of 1000 K. Substances of many different kinds show negative thermal expansion, especially at low temperatures. In this article we review the underlying thermodynamics, emphasizing the roles of thermal stress and elasticity. We also discuss vibrational and non-vibrational mechanisms operating on the atomic scale that are responsible for negative expansion, both isotropic and anisotropic, in a wide range of materials. (topical review)

  2. Proposed diagnostic criteria for internet addiction.

    Science.gov (United States)

    Tao, Ran; Huang, Xiuqin; Wang, Jinan; Zhang, Huimin; Zhang, Ying; Li, Mengchen

    2010-03-01

    The objective of this study was to develop diagnostic criteria for internet addiction disorder (IAD) and to evaluate the validity of our proposed diagnostic criteria for discriminating non-dependent from dependent internet use in the general population. This study was conducted in three stages: the developmental stage (110 subjects in the survey group; 408 subjects in the training group), where items of the proposed diagnostic criteria were developed and tested; the validation stage (n = 405), where the proposed criteria were evaluated for criterion-related validity; and the clinical stage (n = 150), where the criteria and the global clinical impression of IAD were evaluated by more than one psychiatrist to determine inter-rater reliability. The proposed internet addiction diagnostic criteria consisted of symptom criterion (seven clinical symptoms of IAD), clinically significant impairment criterion (functional and psychosocial impairments), course criterion (duration of addiction lasting at least 3 months, with at least 6 hours of non-essential internet usage per day) and exclusion criterion (exclusion of dependency attributed to psychotic disorders). A diagnostic score of 2 + 1, where the first two symptoms (preoccupation and withdrawal symptoms) and at least one of the five other symptoms (tolerance, lack of control, continued excessive use despite knowledge of negative effects/affects, loss of interests excluding internet, and use of the internet to escape or relieve a dysphoric mood) was established. Inter-rater reliability was 98%. Our findings suggest that the proposed diagnostic criteria may be useful for the standardization of diagnostic criteria for IAD.

  3. ORIGINAL ARTICLES Evaluation of a diagnostic algorithm for smear ...

    African Journals Online (AJOL)

    2005-04-30

    Apr 30, 2005 ... To evaluate the diagnostic accuracy of and reduction in diagnostic delay attributable to a clinical algorithm used for the diagnosis of smear-negative pulmonarytuberculosi&. (SNPTB) in HfV-infected adults. Design. An algorithm was designed to facilitate clinico- radiological diagnosis of pulmonary TB (PTB) ...

  4. Kinetic studies with iodine-123-labeled serum amyloid P component in patients with systemic AA and AL amyloidosis and assessment of clinical value

    NARCIS (Netherlands)

    Jager, PL; Hazenberg, BPC; Franssen, EJF; Limburg, PC; van Rijswijk, MH; Piers, DA

    In systemic amyloidosis, widespread amyloid deposition interferes with organ function, frequently with fatal consequences. Diagnosis rests on demonstrating amyloid deposits in the tissues, traditionally with histology although scintigraphic imaging with radiolabeled serum amyloid P component (SAP)

  5. Use of iodine-123 metaiodobenzylguanidine myocardial imaging to predict the effectiveness of {beta}-blocker therapy in patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Fukuoka, Shuji [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Hayashida, Kohei [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Hirose, Yoshiaki [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Shimotsu, Yoriko [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Ishida, Yoshio [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Kakuchi, Hiroyuki [Department of Internal Medicine, National Cardiovascular Center, Osaka (Japan); Eto, Tanenao [First Department of Internal Medicine, Miyazaki Medical College, Miyazaki (Japan)

    1997-05-01

    We studied 13 patients with dilated cardiomyopathy (DCM) and seven normal subjects. We obtained myocardial SPET images 15 min and 4 h after administration of {sup 123}I-MIBG (111 MBq). Studies were performed in the patients with DCM before and 1 and 3 months after the administration of metoprolol and in the normal subjects. We calculated the regional {sup 123}I-MIBG washout rate (r-WR) in the SPET image, and the global {sup 123}I-MIBG washout rate (g-WR) and heart-mediastinum activity ratio (H/M) using the anterior planar image. We classified patients into those showing a {>=}5% increase in LV ejection fraction (LVEF) at 3 months compared with LVEF values before the treatment (group I, n=7) and those showing a <5% increase in LVEF (group II, n=6). In normal subjects, the r-WR values in each of the anterior, lateral, septal and inferior segments were significantly lower than those in groups I and II. These values were 18%{+-}9%, 18%{+-}15%, 20%{+-}12% and 21%{+-}15%, respectively. This study demonstrated that with regional assessment {sup 123}I-MIBG SPET imaging can be used to predict the functional improvement of LVEF at 1 month of {beta}-blocker therapy in patients with DCM. (orig./VHE). With 4 figs., 1 tab.

  6. Myocardial metabolic abnormalities in hypertrophic cardiomyopathy assessed by iodine-123-labeled beta-methyl-branched fatty acid myocardial scintigraphy and its relation to exercise-induced ischemia

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakamura, Yasuyuki; Takahashi, Masayuki; Mitsunami, Kenichi; Kinoshita, Masahiko

    1998-01-01

    Reversible thallium-201 ( 201 Tl) abnormalities during exercise stress have been used as markers of myocardial ischemia in hypertrophic cardiomyopathy (HCM) and are most likely to identify relatively underperfused myocardium. Although metabolic abnormalities in HCM were reported, the relationship between impaired energy metabolism and exercise-induced ischemia has not been fully elucidated as yet. To assess the relationship between myocardial perfusion abnormalities and fatty acid metabolic abnormalities, 28 patients with HCM underwent exercise 201 Tl and rest 123 I-15-(p-iodophenyl)-3-methyl pentadecanoic acid (BMIPP) scintigraphy. Perfusion abnormalities were observed by exercise 201 Tl in 19/28 patients with HCM. 123 I-BMIPP uptake was decreased compared with delayed 201 Tl in 106/364 (29%) of the total myocardial segments (p 123 I-BMIPP and 201 Tl was observed more often in the 49/75 (65%) segments with reversible exercise 201 Tl defects (p 123 I-BMIPP and 201 Tl suggests that myocardial ischemia may play an important role in metabolic abnormalities in HCM. (author)

  7. Initial experience with single-photon emission tomography using iodine-123-labelled 2β-carbomethoxy-3β(4-iodophnyl)tropane in human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Vanninen, E.; Laulumaa, V.; Hartikainen, P.; Laensimies, E.

    1993-01-01

    The iodinated cocaine analogue 2β-carbomethoxy-3β-(4-iodophenyl)tropane ([ 123 I]β-CIT), a new dopamine transporter, was preliminarily tested in human brain. Two normal volunteers and two patients with Parkinson's disease were imaged with a high-resolution single-photon emission tomography scanner. The specific binding of [ 123 I]β-CIT in the basal ganglia and thalamus was high in normal volunteers. In addition, there was relatively intense uptake in the medial prefrontal area. Patients with Parkinson's disease who were older than controls showed significantly lower specific binding in the basal ganglia and thalamus and no uptake in the medial prefrontal cortex. This decrease in the dopamine transporter may be age related. (orig.)

  8. Synthesis of iodine-123 labelled analogues of the partial agonist (S)-and (R)-bretazenil for the study of CNS benzodiazepine receptors using SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Katsifis, Andrew; Mattner, Filomena; McPhee, Meredith; Kassiou, Michael; Najdovski, Ljubco; Dikic, Branko [Australian Nuclear Science and Technology Organisation, Radiopharmaceutical Div., Menai, Sydney, NSW (Australia)

    1996-09-01

    The (S) and (R)-[{sup 123}I]iodinated analogues of the benzodiazepine receptor partial agonist bretazenil have been synthesized for study of the central benzodiazepine receptor using SPECT, (S)- and (R)-[{sup 123}I]iodobretazenil were prepared from the appropriate tin precursors by electrophilic iododestannylation with Na[{sup 123}I] in the presence of Chloramine-T. The products were purified by semi-preparative reverse-phase HPLC with radiochemical yields of 80% in a total synthesis time of 50 minutes. The specific activity was determined to be greater than 2500 Ci/mmol. The radiochemical and chemical purity assessed by radio-TLC and HPLC were found to be 98%. The enantiomeric purity of the (S) and (R) isomers were greater than 97% as assessed by analytical chiral HPLC analysis. (author).

  9. Evaluation of ischemia and myocardial viability in patients with coronary artery disease (CAD) with iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP)

    Energy Technology Data Exchange (ETDEWEB)

    Kropp, J.; Joergens, M.; Glaenzer, K.P.; Luederitz, B.; Biersack, H.J. [Bonn Univ. (Germany); Knapp, F.F. Jr. [Oak Ridge National Lab., TN (United States)

    1993-10-01

    Twenty patients with coronary artery disease (CAD) controlled by coronary arteriography (CA) and biplane left ventricular cineventriculography (LVCV) were investigated with the 15- (p[I-123]iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue. During maximal symptom limited exercise 5 mCi (200 MBq) of BMIPP were injected followed by two SPECT studies within three hours. After another 30 min, with the patient at rest a third SPECT was performed after reinjection of 3 mCi (100 MBq) BMIPP. Visual inspection of the short and long axis slices and quantitative comparison of the short axis slices of the tomograms were performed to grade BMIPP uptake and refill and detect turnover abnormalities. These were addressed either as scar or as ischemia and compared to CA and a graded score of regional wall motion by LVCV which provided values for sensitivity (SE) and specificity (SP) to detect CAD. Fifteen infarctions had corresponded clinical, angiographic and scintigraphic findings in 93%.

  10. Iodine-123 IMP SPECT before and after bypass surgery in a patient with occlusion of left anterior and middle cerebral arteries with basal abnormal telangiectasis (unilateral Moyamoya disease)

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Takishima, Teruo; Kaizu, Hiroyuki; Sugimoto, Eiichi

    1987-01-01

    A case of left anterior and middle cerebral arterial occlusion with angiographic features similar to Moyamoya disease was reported. IMP SPECT of the patient revealed the success of bypass surgery clearly. The patient complained of transient right hemiparesis with aphasia 4 times. The cerebral arteriography disclosed occlusions of left anterior and middle cerebral arteries at their proximal portions. Right internal carotid and its branches were normal. I-123 IMP SPECT study showed hypoperfusion in left temporal lobe, basal ganglia with incomplete reperfusion on the delayed (4 hours after injection) SPECT images. After the superficial temporal-middle cerebral artery anastomosis, I-123 IMP SPECT showed improvement of the brain blood flow. I-123 IMP SPECT was very useful in detecting the ischemic areas and evaluating the revascularizing surgery in this case. (author)

  11. Myocardial metabolic abnormalities in hypertrophic cardiomyopathy assessed by iodine-123-labeled beta-methyl-branched fatty acid myocardial scintigraphy and its relation to exercise-induced ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Shinro; Nakamura, Yasuyuki; Takahashi, Masayuki; Mitsunami, Kenichi; Kinoshita, Masahiko [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-03-01

    Reversible thallium-201 ({sup 201}Tl) abnormalities during exercise stress have been used as markers of myocardial ischemia in hypertrophic cardiomyopathy (HCM) and are most likely to identify relatively underperfused myocardium. Although metabolic abnormalities in HCM were reported, the relationship between impaired energy metabolism and exercise-induced ischemia has not been fully elucidated as yet. To assess the relationship between myocardial perfusion abnormalities and fatty acid metabolic abnormalities, 28 patients with HCM underwent exercise {sup 201}Tl and rest {sup 123}I-15-(p-iodophenyl)-3-methyl pentadecanoic acid (BMIPP) scintigraphy. Perfusion abnormalities were observed by exercise {sup 201}Tl in 19/28 patients with HCM. {sup 123}I-BMIPP uptake was decreased compared with delayed {sup 201}Tl in 106/364 (29%) of the total myocardial segments (p<0.01, McNemar symmetry test). Such disparity between {sup 123}I-BMIPP and {sup 201}Tl was observed more often in the 49/75 (65%) segments with reversible exercise {sup 201}Tl defects (p<0.001). Our results indicate that exercise-induced myocardial ischemia exists in HCM, resulting in metabolic abnormalities. The combination of {sup 123}I-BMIPP and {sup 201}Tl suggests that myocardial ischemia may play an important role in metabolic abnormalities in HCM. (author)

  12. Iodine-123 N-methyl-4-iododexetimide: a new radioligand for single-photon emission tomographic imaging of myocardial muscarinic receptors

    International Nuclear Information System (INIS)

    Hicks, R.J.; Kassiou, M.; Eu, P.; Katsifis, A.G.; Garra, M.; Power, J.; Najdovski, L.; Lambrecht, R.M.

    1995-01-01

    Cardiac muscarinic receptor ligands suitable for positron emission tomography have previously been characterised. Attempts to develop radioligands of these receptors suitable for single-photon emission tomographic (SPET) imaging have not been successful due to high lung retention and high non-specific binding of previously investigated potential tracers. The purpose of this study was to evaluate the biodistribution and in vivo imaging characteristics of a new radiopharmaceutical, [ 123 I]N-methyl-4-iododexetimide. Biodistribution studies performed in rats showed high cardiac uptake (2.4% ID/g) 10 min after injection with a heart to lung activity ratio of 5:1. Specificity and stereoselectivity of cardiac binding were demonstrated using blocking experiments in rats. Dynamic imaging studies in anaesthetised greyhounds demonstrated rapid and high myocardial uptake and low lung binding with stable heart to lung activity ratios of >2.5:1 between 10 and 30 min, making SPET imaging feasible. Administration of an excess of an unlabelled muscarinic antagonist, methyl-quinuclidinyl benzylate rapidly displaced myocardial activity to background levels and the pharmacologically inactive enantiomer, [ 123 I]N-methyl-4-iodolevetimide, had no detectable cardiac uptake, indicating specific and stereoselective muscarinic receptor binding. SPET revealed higher activity in the inferior than in the anterior wall, this being consistent with previously described regional variation of cardiac parasympathetic innervation. [ 123 I]N-methyl-4-iododexetimide shows promise as an imaging agent for muscarinic receptor distribution in the heart and may be helpful in evaluating diverse cardiac diseases associated with altered muscarinic receptor function, including heart failure and diabetic heart disease. (orig.)

  13. Iodine-123 labelled N-(2-fluoroethyl)-2β-carbomethoxy-3β-(4-iodophenyl)nortropane for dopamine transporter imaging in the living human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; AAkerman, K.; Bergstroem, K.A.; Karhu, J.; Hiltunen, J.; Haukka, J.; Heikkinen, J.; Tiihonen, J.; Wang, S.; Neumeyer, J.L.

    1995-01-01

    Here we report a pilot comparison of [ 123 I]β-CIT and [ 123 I]β-CIT-FP with a new tropane derivative, [ 123 I]N-(2-fluoroethyl)-2β-carbomethoxy-3β-(4-iodophenyl)nortropane ([ 123 I]β-CIT-FE), using SPET imaging in four healthy male subjects. Peak uptake of [ 123 I]β-CIT-FE into the basal ganglia occurred very rapidly (0.5 h after injection of tracer), after which the striatal washout obeyed a bi-exponential form. The specific DAT binding of [ 123 I]β-CIT-FE into the basal ganglia was somewhat less (0.785±0.117) than that of [ 123 I]β-CIT (0.922±0.004) or [ 123 I]β-CIT-FP (0.813±0.047). All these tracers have excellent imaging quality in healthy control subjects. However, the relatively fast washout of [ 123 I]β-CIT-FE and low temporal resolution of older SPET cameras may limit the use of this tracer to the measurement of the DAT density. (orig./UG)

  14. Iodine-123 labelled N-(2-fluoroethyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane for dopamine transporter imaging in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); AAkerman, K. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Karhu, J. [Dept. of Clinical Neurophysiology, Kuopio Univ. Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Heikkinen, J. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Tiihonen, J. [Dept. of Forensic Psychiatry, Niuvanniemi Hospital, Kuopio (Finland); Wang, S. [Research Biochemical International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemical International (RBI), Natick, MA (United States)

    1995-07-01

    Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and [{sup 123}I]{beta}-CIT-FP with a new tropane derivative, [{sup 123}I]N-(2-fluoroethyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane ([{sup 123}I]{beta}-CIT-FE), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FE into the basal ganglia occurred very rapidly (0.5 h after injection of tracer), after which the striatal washout obeyed a bi-exponential form. The specific DAT binding of [{sup 123}I]{beta}-CIT-FE into the basal ganglia was somewhat less (0.785{+-}0.117) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004) or [{sup 123}I]{beta}-CIT-FP (0.813{+-}0.047). All these tracers have excellent imaging quality in healthy control subjects. However, the relatively fast washout of [{sup 123}I]{beta}-CIT-FE and low temporal resolution of older SPET cameras may limit the use of this tracer to the measurement of the DAT density. (orig./UG)

  15. Demonstration of a reduction in muscarinic receptor binding in early Alzheimer's disease using iodine-123 dexetimide single-photon emission tomography

    International Nuclear Information System (INIS)

    Claus, J.J.; Dubois, E.A.; Booij, J.; Habraken, J.; Munck, J.C. van; Herk, M. van; Verbeeten, B. Jr.; Royen, E.A. van

    1997-01-01

    Decreased muscarinic receptor binding has been suggested in single-photon emission tomography (SPET) studies of Alzheimer's disease. However, it remains unclear whether these changes are present in mildly demented patients, and the role of cortical atrophy in receptor binding assessment has not been investigated. We studied muscarinic receptor binding normalized to neostriatum with SPET using [ 123 I[4-iododexetimide in five mildly affected patients with probable Alzheimer's disease and in five age-matched control subjects. Region of interest (ROI) analysis was performed in a consensus procedure blind to clinical diagnosis using matched magnetic resonance (MRI) images. Cortical atrophy was assessed by calculating percentages of cerebrospinal fluid in each ROI. An observer study with three observers was conducted to validate this method. Alzheimer patients showed statistically significantly less [ 123 I[4-iododexetimide binding in left temporal and right temporo-parietal cortex compared with controls, independent of age, sex and cortical atrophy. Mean intra-observer variability was 3.6% and inter-observer results showed consistent differences in [ 123 I[4-iododexetimide binding between observers. However, differences between patients and controls were comparable among observers and statistically significant in the same regions as in the consensus procedure. Using an MRI-SPET matching technique, we conclude that [ 123 I[4-iododexetimide binding is reduced in patients with mild probable Alzheimer's disease in areas of temporal and temporo-parietal cortex. (orig.). With 1 fig., 4 tabs

  16. Isotropic Single Negative Metamaterials

    Directory of Open Access Journals (Sweden)

    P. Protiva

    2008-09-01

    Full Text Available This paper presents the application of simple, and therefore cheap, planar resonators for building 3D isotropic metamaterials. These resonators are: a broadside-coupled split ring resonator with a magnetic response providing negative permeability; an electric dipole terminated by a loop inductor together with a double H-shaped resonator with an electric response providing negative permittivity. Two kinds of 3D isotropic single negative metamaterials are reported. The first material consists of unit cells in the form of a cube bearing on its faces six equal planar resonators with tetrahedral symmetry. In the second material, the planar resonators boxed into spherical plastic shells and randomly distributed in a hosting material compose a real 3D volumetric metamaterial with an isotropic response. In both cases the metamaterial shows negative permittivity or permeability, according to the type of resonators that are used. The experiments prove the isotropic behavior of the cells and of the metamaterial specimens.

  17. Psychologists' Diagnostic Processes during a Diagnostic Interview

    NARCIS (Netherlands)

    Groenier, M.; Beerthuis, R.J.; Pieters, J.M.; Witteman, C.L.M.; Swinkels, J.A.

    2011-01-01

    In mental health care, psychologists assess clients’ complaints, analyze underlying problems, and identify causes for these problems, to make treatment decisions. We present a study on psychologists’ diagnostic processes, in which a mixed-method approach was employed. We aimed to identify a common

  18. Psychologists' diagnostic processes during a diagnostic interview

    NARCIS (Netherlands)

    Groenier, Marleen; Beerthuis, Vos R.J.; Pieters, Julius Marie; Witteman, C.L.M.; Witteman, Cilia L.M.; Swinkels, Jan A.

    2011-01-01

    In mental health care, psychologists assess clients’ complaints, analyze underlying problems, and identify causes for these problems, to make treatment decisions. We present a study on psychologists’ diagnostic processes, in which a mixed-method approach was employed. We aimed to identify a common

  19. NEGATION AFFIXES IN ENGLISH

    Directory of Open Access Journals (Sweden)

    Dedy Subandowo -

    2017-02-01

    Full Text Available Abstract: This research entitled "Negation Affixes in English". This study is aimed to describe the various negation affixes in English, morphological process, morphophonemic and meaning. The research data were taken from various sources of English grammar book, morphology, research journal and the book which relatees to the research. English grammar books used in this study are written by Otto Jesperson, Marcella Frank, Greenbaum and Geoffrey Leech.  The method used in this research is the descriptive-qualitative method. While the data collection techniques are performed by using jot-down method. And the results of analysis are presented in tabular form and descriptive method. The result of the research shows that English has six types of negative affixes which are categorized by the intensity of its appearance, such as dis-, in-, non-, un-, anti- and -less. Based on the function, negation affixes are divided into several categories such as adjectives, nouns, verbs, and adverbs. The morphophonemic affix in- has four allomorphs, they are in-, im-, il- and ir- . While the analysis revealed that negation affixes have some basic meanings, such as ‘not’, ‘without’, and ‘anti’.

  20. Bangladesh Jobs Diagnostic

    OpenAIRE

    Farole, Thomas; Cho, Yoonyoung

    2017-01-01

    This Jobs Diagnostic presents the characteristics and constraints of the labor market in Bangladesh, identifies the objectives of the jobs agenda, and proposes a policy framework to progress toward them. This multisectoral diagnostic assesses the relationships between supply- and demand-side factors that interact to determine job creation, quality, and inclusion outcomes. Understanding the...

  1. Nedtrykt af negative nyheder

    DEFF Research Database (Denmark)

    Skovsgaard, Morten; Søberg, Pernille Frantz

    2016-01-01

    I adskillige år er det blevet debatteret, hvorvidt nyhedernes negative fokus har konsekvenser for borgerne, og om det i sid-ste ende får flere til at vende ryggen til nyhederne. Vores viden om effekterne af positive og negative nyheder er dog begrænset, og derfor undersøges det i denne artikel......, hvordan henholdsvis positive og negative tv-nyheder påvirker seernes humør, hukom-melse af information fra indslaget og lyst til at se yderligere tv-nyheder. Det gør vi i et survey-eksperiment (N=204), hvor tre grupper så enten et originalt indslag eller det samme indslag klippet med henholdsvis et...

  2. On Various Negative Translations

    Directory of Open Access Journals (Sweden)

    Gilda Ferreira

    2011-01-01

    Full Text Available Several proof translations of classical mathematics into intuitionistic mathematics have been proposed in the literature over the past century. These are normally referred to as negative translations or double-negation translations. Among those, the most commonly cited are translations due to Kolmogorov, Godel, Gentzen, Kuroda and Krivine (in chronological order. In this paper we propose a framework for explaining how these different translations are related to each other. More precisely, we define a notion of a (modular simplification starting from Kolmogorov translation, which leads to a partial order between different negative translations. In this derived ordering, Kuroda and Krivine are minimal elements. Two new minimal translations are introduced, with Godel and Gentzen translations sitting in between Kolmogorov and one of these new translations.

  3. Negative ion sourcery

    International Nuclear Information System (INIS)

    Os, C.F.A. van.

    1989-01-01

    The work described in this thesis is involved by current research programs in the field of nuclear-fusion. A brief introduction to fusion is given, anticipated problems related to current drive of the fusion plasma are pinpointed and probable suggestions to overcome these problems are described. One probable means for current drive is highlighted; Neutral Beam Injection (NBI). This is based on injecting a 1 MeV neutral hydrogen or deuterium beam into a fusion plasma. Negative ions are needed as primary particles because they can easily be neutralized at 1 MeV. The two current schemes for production of negative ions are described, volume production and negative surface ionization. The latter method is extensively studied in this thesis. (author). 171 refs.; 55 figs.; 7 tabs

  4. Diagnostic tests based on human basophils

    DEFF Research Database (Denmark)

    Kleine-Tebbe, Jörg; Erdmann, Stephan; Knol, Edward F

    2006-01-01

    -maximal responses, termed 'intrinsic sensitivity'. These variables give rise to shifts in the dose-response curves which, in a diagnostic setting where only a single antigen concentration is employed, may produce false-negative data. Thus, in order to meaningfully utilize the current basophil activation tests....... Diagnostic studies using CD63 or CD203c in hymenoptera, food and drug allergy are critically discussed. Basophil-based tests are indicated for allergy testing in selected cases but should only be performed by experienced laboratories....

  5. Depressionens negative spiral

    DEFF Research Database (Denmark)

    Munk, Karen

    2006-01-01

    Artiklen formidler resultater fra en longitudinel undersøgelse af det selvforstærkende, negative samspil imellem udvikling og vedligeholdelse af alderdomsdepression via primære miljøbelastninger og via  den deprimerede ældre som belastning for miljøet, som i sin tur "svarer negativt" på lidelsen og...

  6. Quantum logic without negation

    Energy Technology Data Exchange (ETDEWEB)

    Zapatrin, R.R. (Dept. of Mathematics, SPb UEF, St. Petersburg (Russian Federation))

    1994-05-01

    The algebraic tools based on generating semigroups are suggested to describe property lattices possessing the relation of exclusivity rather than the operation of negation. The reduction to standard situation of orthocomplemented and orthomodular lattices is described. As an example of non-orthocomplementable property lattice that of a hypothetical ''topologymeter'' is studied. (orig.)

  7. The Negative Repetition Effect

    Science.gov (United States)

    Mulligan, Neil W.; Peterson, Daniel J.

    2013-01-01

    A fundamental property of human memory is that repetition enhances memory. Peterson and Mulligan (2012) recently documented a surprising "negative repetition effect," in which participants who studied a list of cue-target pairs twice recalled fewer targets than a group who studied the pairs only once. Words within a pair rhymed, and…

  8. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  9. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  10. Melioidosis Diagnostic Workshop, 20131

    Science.gov (United States)

    AuCoin, David; Baccam, Prasith; Baggett, Henry C.; Baird, Rob; Bhengsri, Saithip; Blaney, David D.; Brett, Paul J.; Brooks, Timothy J.G.; Brown, Katherine A.; Chantratita, Narisara; Cheng, Allen C.; Dance, David A.B.; Decuypere, Saskia; Defenbaugh, Dawn; Gee, Jay E.; Houghton, Raymond; Jorakate, Possawat; Lertmemongkolchai, Ganjana; Limmathurotsakul, Direk; Merlin, Toby L.; Mukhopadhyay, Chiranjay; Norton, Robert; Peacock, Sharon J.; Rolim, Dionne B.; Simpson, Andrew J.; Steinmetz, Ivo; Stoddard, Robyn A.; Stokes, Martha M.; Sue, David; Tuanyok, Apichai; Whistler, Toni; Wuthiekanun, Vanaporn; Walke, Henry T.

    2015-01-01

    Melioidosis is a severe disease that can be difficult to diagnose because of its diverse clinical manifestations and a lack of adequate diagnostic capabilities for suspected cases. There is broad interest in improving detection and diagnosis of this disease not only in melioidosis-endemic regions but also outside these regions because melioidosis may be underreported and poses a potential bioterrorism challenge for public health authorities. Therefore, a workshop of academic, government, and private sector personnel from around the world was convened to discuss the current state of melioidosis diagnostics, diagnostic needs, and future directions. PMID:25626057

  11. Melioidosis diagnostic workshop, 2013.

    Science.gov (United States)

    Hoffmaster, Alex R; AuCoin, David; Baccam, Prasith; Baggett, Henry C; Baird, Rob; Bhengsri, Saithip; Blaney, David D; Brett, Paul J; Brooks, Timothy J G; Brown, Katherine A; Chantratita, Narisara; Cheng, Allen C; Dance, David A B; Decuypere, Saskia; Defenbaugh, Dawn; Gee, Jay E; Houghton, Raymond; Jorakate, Possawat; Lertmemongkolchai, Ganjana; Limmathurotsakul, Direk; Merlin, Toby L; Mukhopadhyay, Chiranjay; Norton, Robert; Peacock, Sharon J; Rolim, Dionne B; Simpson, Andrew J; Steinmetz, Ivo; Stoddard, Robyn A; Stokes, Martha M; Sue, David; Tuanyok, Apichai; Whistler, Toni; Wuthiekanun, Vanaporn; Walke, Henry T

    2015-02-01

    Melioidosis is a severe disease that can be difficult to diagnose because of its diverse clinical manifestations and a lack of adequate diagnostic capabilities for suspected cases. There is broad interest in improving detection and diagnosis of this disease not only in melioidosis-endemic regions but also outside these regions because melioidosis may be underreported and poses a potential bioterrorism challenge for public health authorities. Therefore, a workshop of academic, government, and private sector personnel from around the world was convened to discuss the current state of melioidosis diagnostics, diagnostic needs, and future directions.

  12. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    High temporal and spatial resolution optical diagnostics of laser performance, energy balance, and applicable plasma probing techniques are reviewed. A variety of spatially, temporally and spectrally resolved x-ray diagnostics techniques and instruments as discussed. Particular emphasis is on high spatial resolution imaging techniques and applications and on high temporal resolution x-ray streak camera applications to exploding pusher target experiments. Finally, particle diagnostics and systems designed to diagnose target performance via yield and temperature measurements and techniques designed to determine the characteristics of compressed targets are discussed

  13. Prenatal Genetic Diagnostic Tests

    Science.gov (United States)

    ... are available for many inherited disorders. The main disadvantage is that diagnostic testing carries a very small ... chromosomes, arranged in order of size. Microarray: A technology that examines all of a person’s genes to ...

  14. National Convective Weather Diagnostic

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current convective hazards identified by the National Convective Weather Detection algorithm. The National Convective Weather Diagnostic (NCWD) is an automatically...

  15. Rotorcraft Diagnostics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Under this SBIR program, Ridgetop will introduce the first low-cost, low-power, and lightweight data monitoring solution for rotorcraft diagnostics. The solution is...

  16. Culture Negative Infective Endocarditits: a Changing Paradigm

    LENUS (Irish Health Repository)

    Daly, A

    2016-05-01

    Traditionally, the modified Duke\\'s criteria, based primarily on positive blood cultures, is used to diagnose Infective Endocarditis (IE). However, reports demonstrate that 31% of cases are diagnosed as Culture Negative Infective Endocarditis (CNIE)1. Consequently, empiric broad-spectrum antibiotics are prescribed to cover unidentified organisms and, as a result, antibiotic therapy may be compromised. Molecular diagnostic techniques aid with identifying causative organisms in cases of CNIE and we question if the increasing use of such technologies will change the local epidemiology of CNIE. We present the first case of Tropheryma whipplei Infective Endocarditis (TWIE) reported in Ireland.

  17. [Diagnostics in osteology].

    Science.gov (United States)

    Jakob, F; Genest, F; Seefried, L; Tsourdi, E; Lapa, C; Hofbauer, L C

    2016-07-01

    Clinical diagnostics in metabolic bone diseases cover a broad spectrum of conventional and state of the art methods ranging from the medical history and clinical examination to molecular imaging. Patient treatment is carried out in an interdisciplinary team due to the multiple interactions of bone with other organ systems. Diagnosis of osteoporosis is supported by high level national guidelines. A paradigm shift concerning the clinical relevance of bone mineral density measurement renders this now to be a strong risk factor rather than a diagnostic parameter, while strengthening the value of other clinical factors for risk assessment. The impact of parameters for muscle mass, structure and function is steadily increasing in all age groups. In order to identify underlying diseases that influence bone metabolism a panel of general laboratory diagnostic parameters is recommended. Markers for bone formation and resorption and specific parameters for the regulation of calcium and phosphate metabolism should be evaluated by specialists because they require diligence in preanalytics and experience in interpretation. Genetic diagnosis is well established for rare bone diseases while diagnostic panels are not yet available for routine diagnostics in polygenetic diseases such as osteoporosis. Conventional radiology is still very important to identify, e. g. fractures, osteolytic and osteoblastic lesions and extraosseous calcifications; however tomography-based methods which combine, e. g. scintigraphy or positron emission technologies with anatomical imaging are of increasing significance. Clinical diagnostics in osteology require profound knowledge and are subject to a dynamic evolution.

  18. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  19. Embedded esophageal foreign body. A diagnostic challenge

    International Nuclear Information System (INIS)

    Bhat, Venkatraman S.; AlSaadi, Khalid A.; Bessiouni, Ibrahim E.; Tuffaha, Amjad S.

    2009-01-01

    Esophageal foreign body (EFB) ingestion is of ubiquitous occurrence in pediatric population. Diagnosis and precise localization of non-radio opaque FB poses considerable challenge. Delayed presentation, poor history, and inconclusive esophagoscopic findings often lead to diagnostic delay. Multidetector computed tomography (MDCT) could be a great option in these situations. We present a case of EFB in a child who presented with failure to thrive, had negative fibreoptic endoscopy, ultimately diagnosed conclusively on MDCT examination. (author)

  20. Negative bone scintigraphy and diffuse osteoblastic breast carcinoma metastases; Scintigraphie osseuse negative et metastases osteocondensantes dans le cancer du sein

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, C.; Resche, I.; Chatal, J.F. [Centre Rene Gauducheau, Service de Medecine Nucleaire, 44 - Saint Herblain (France); Campone, M.; Fumoleau, P. [Centre Rene Gauducheau, Service d' Oncologie Medicale, 44 - Saint Herblain (France); Cussac, A. [Centre Rene Gauducheau, Service de Radiotherapie, 44 - Saint Herblain (France); Meingan, P. [Centre Rene Gauducheau, Service d' Imagerie Medicale, 44 - Saint Herblain (France)

    2001-03-01

    The authors report a case of metastatic breast carcinoma with a negative bone scan in spite of densely sclerotic metastases on radiography. The literature is reviewed with regard to the subject of such negative bone scan in this clinical situation and the alternative possibilities to document the diagnostic of breast bone metastases are discussed. The 'normal' scintigraphic pattern is not clearly explained. (authors)

  1. Negative leave balances

    CERN Multimedia

    Human Resources Department

    2005-01-01

    Members of the personnel entitled to annual leave and, where appropriate, saved leave and/or compensatory leave are requested to take note of the new arrangements described below, which were recommended by the Standing Concertation Committee (SCC) at its meeting on 1Â September 2005 and subsequently approved by the Director-General. The changes do not apply to members of the personnel participating in the Progressive Retirement Programme (PRP) or the Part-time Work as a pre-retirement measure, for whom the specific provisions communicated at the time of joining will continue to apply. Â Negative balances in annual leave, saved leave and/or compensatory leave accounts at the end of the leave year (30th September) and on the date on which bonuses are credited to the saved leave account (31st December): Where members of the personnel have a leave account with a negative balance on 30Â September and/or 31Â December, leave will automatically be transferred from one account to another on the relevant dates i...

  2. Negative leave balances

    CERN Multimedia

    Human Resources Department

    2005-01-01

    Members of the personnel entitled to annual leave and, where appropriate, saved leave and/or compensatory leave are requested to take note of the new arrangements described below, which were recommended by the Standing Concertation Committee (SCC) at its meeting on 1 September 2005 and subsequently approved by the Director-General. The changes do not apply to members of the personnel participating in the Progressive Retirement Programme (PRP) or the Part-time Work as a pre-retirement measure, for whom the specific provisions communicated at the time of joining will continue to apply.  Negative balances in annual leave, saved leave and/or compensatory leave accounts at the end of the leave year (30th September) and on the date on which bonuses are credited to the saved leave account (31st December): Where members of the personnel have a leave account with a negative balance on 30 September and/or 31 December, leave will automatically be transferred from one account to another on the relevant dates in or...

  3. Pitfalls in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Peh, Wilfred C.G. (ed.) [Khoo Teck Puat Hospital (Singapore). Dept. of Diagnostic Radiology

    2015-04-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  4. Pitfalls in diagnostic radiology

    International Nuclear Information System (INIS)

    Peh, Wilfred C.G.

    2015-01-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  5. Diagnostic imaging of skeletal metastases

    International Nuclear Information System (INIS)

    Scutellari, P. N.; Addonisio, G.; Righi, R.; Giganti, M.

    2000-01-01

    Purpose of this article is to present an algorithm for detection and diagnosis of skeletal metastases, which may be applied differently in symptomatic and asymptomatic cancer patients. February to March 1999 it was randomly selected and retrospectively reviewed the clinical charts of 100 cancer patients (70 women and 30 men; mean age: 63 years, range: 55-87). All the patients had been staged according to TNM criteria and had undergone conventional radiography and bone scan; when findings were equivocal, CT and MRI had been performed too. The primary lesions responsible for bone metastases were sited in the: breast (51 cases), colon (30 cases: 17 men and 13 women), lung (7 cases: 6 men and 1 woman), stomach (4 cases: 2 men and 2 women), skin (4 cases: 3 men and 1 woman), kidney (2 men), pleura (1 woman), and finally liver (1 man). The most frequent radiographic pattern was the lytic type (52%), followed by osteosclerotic, mixed, lytic vs mixed and osteosclerotic vs lytic patterns. The patients were divided into two groups: group A patients were asymptomatic and group B patients had local symptoms and/or pain. Skeletal metastases are the most common malignant bone tumors: the spine and the pelvis are the most frequent sites of metastasis, because of the presence of high amounts of red (hematopoietic active) bone marrow. Pain is the main symptom, even though many bone metastases are asymptomatic. Pathological fractures are the most severe consequences. With the algorithm for detection and diagnosis of skeletal metastases two different diagnostic courses are available for asymptomatic and symptomatic patients. Bone scintigraphy remains the technique of choice in asymptomatic patients in whom skeletal metastases are suspected. However this technique, though very sensitive, is poorly specific, and thus a negative bone scan finding is double-checked with another physical examination: if the findings remain negative, the diagnostic workup is over. On the contrary, in

  6. ORION laser target diagnostics

    International Nuclear Information System (INIS)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.

    2012-01-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  7. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  8. Nova diagnostics summary

    International Nuclear Information System (INIS)

    Slivinsky, V.W.; Drake, R.P.

    1985-01-01

    The authors intend that Nova be the best diagnosed ICF research facility in operation today. The authors experience in providing advanced diagnostics for previous laser systems will be extended at Nova, and will be challenged by the development of new instrumentation to diagnose the more advanced targets made possible by this powerful laser. Previous experience has shown that to understand target performance, the authors must have as complete a set of diagnostics as possible. The Nova diagnostics are divided into two sets: the basic set required for the initial Nova experiments and the more advanced set for later, generally more complex, experiments. The basic set will be operational for the first Nova shots; it was a Nova line item funded with Nova construction money. This basic set is presented in a table

  9. [Negative pressure therapy: NPT].

    Science.gov (United States)

    Maillard, H

    2015-01-01

    Negative pressure therapy or treatment (NPT) is used very frequently in hospitals in both surgical and medical departments. NPT consists of maintaining the wound surface at a pressure below ambient atmospheric pressure by means of a specially designed dressing attached to a depressurisation device as well as a system to drain exudate. NPT has been shown to be beneficial in increasing blood flow, thanks to feedback resulting from the decreased oxygen pressure, angiogenesis and reduction of the wound surface area. The French Health Authority (HAS) has issued recommendations for good use in a specific and limited series of applications. NPT may be used in post-traumatic or post-surgical wounds, burns, and in chronic wounds, such as bedsores and ulcers. It is also effective as an adjuvant treatment for infected wounds. In recent years, various different NPT devices have become commercially available. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Laser diagnostics of biofractals

    International Nuclear Information System (INIS)

    Ushenko, A G

    1999-01-01

    An optical approach to the problem of modeling and diagnostics of the structures of biofractal formations was considered in relation to human bone tissue. A model was proposed for the optical properties of this tissue, including three levels of fractal organisation: microcrystaline, macrocrystallne, and architectural. The studies were based on laser coherent polarrimetry ensuring the retrieval of the fullest information about the optical and polarisation properties of bone tissue. A method was developed for contactless noninvasive diagnostics of the orientational and mineralogical structure of bone tissue considered as a biofractal. (lasers in medicine)

  11. Diagnostic Imaging Workshop

    International Nuclear Information System (INIS)

    Sociedad Argentina de Fisica Medica

    2012-01-01

    The American Association of Physicist in Medicine (AAPM), the International Organization for Medical Physics (IOMP) and the Argentina Society of Medical Physics (SAFIM) was organized the Diagnostic Imaging Workshop 2012, in the city of Buenos Aires, Argentina. This workshop was an oriented training and scientific exchange between professionals and technicians who work in medical physics, especially in the areas of diagnostic imaging, nuclear medicine and radiotherapy, with special emphasis on the use of multimodal imaging for radiation treatment, planning as well of quality assurance associates.

  12. Diagnostic Imaging for Implants

    Directory of Open Access Journals (Sweden)

    Sanjay M Mallya

    2004-01-01

    Full Text Available Dental implants are a popular modality for permanent tooth replacement. The key to successful implant placement, its subsequent osseointegration and the final prosthetic rehabilitation is proper preoperative assessment. Diagnostic imaging plays an important role in the pre- and post-surgical evaluation process. Imaging is used to evaluate suitability of implant sites, aid in selection of appropriate implants, and finally evaluate implant placement and osseointegration. This article reviews the role of diagnostic imaging in the various phases and the advantages and limitations of the numerous imaging modalities.

  13. Designing high speed diagnostics

    Science.gov (United States)

    Veliz Carrillo, Gerardo; Martinez, Adam; Mula, Swathi; Prestridge, Kathy; Extreme Fluids Team Team

    2017-11-01

    Timing and firing for shock-driven flows is complex because of jitter in the shock tube mechanical drivers. Consequently, experiments require dynamic triggering of diagnostics from pressure transducers. We explain the design process and criteria for setting up re-shock experiments at the Los Alamos Vertical Shock Tube facility, and the requirements for particle image velocimetry and planar laser induced fluorescence measurements necessary for calculating Richtmeyer-Meshkov variable density turbulent statistics. Dynamic triggering of diagnostics allows for further investigation of the development of the Richtemeyer-Meshkov instability at both initial shock and re-shock. Thanks to the Los Alamos National Laboratory for funding our project.

  14. Factors associated with negative T-SPOT.TB results among smear-negative tuberculosis patients in China.

    Science.gov (United States)

    Kang, Wanli; Wu, Meiying; Yang, Kunyun; Ertai, A; Wu, Shucai; Geng, Shujun; Li, Zhihui; Li, Mingwu; Pang, Yu; Tang, Shenjie

    2018-03-09

    We compared the positive rates of T-SPOT.TB and bacterial culture in the smear-negative PTB, and analyzed the factors affecting the results of negative T-SPOT.TB and bacterial culture. Retrospective evaluation of data from smear-negative PTB patients who underwent T-SPOT.TB and bacterial culture were done. The agreement and concordance were analyzed between T-SPOT.TB and bacterial culture. Multivariable logistic regression analysis was used to explore the factors associated with positive results of T-SPOT.TB and bacterial culture in smear-negative PTB. 858 eligible smear-negative PTB patients were included in the study. The agreement rate was 25.6% (22.7~28.5%) between T-SPOT.TB and bacterial culture in smear- negative PTB patients. The positive rate of T-SPOT.TB was higher than that of bacterial culture in smear-negative PTB patients (p TB and bacterial culture (p > 0.05). Using multivariable logistic regression analysis we found that older age ≥ 60 years (OR = 0.469, 95% CI: 0.287-0.768) and decreased albumin (OR = 0.614, 95% CI: 0.380-0.992) were associated with negative diagnostic results of T-SPOT.TB in smear-negative PTB patients. Female (OR = 0.654, 95% CI: 0.431-0.992) were associated with negative diagnostic results of bacteria culture in smear-negative PTB patients. Our results indicated that the older age and decreased albumin were independently associated with negative T-SPOT.TB responses.

  15. Regulation and quality evaluation system for HIV diagnostics in China.

    Science.gov (United States)

    Xu, Sihong; Huang, Weijin; Zhang, Li; An, Juanjuan; Li, Xiuhua; Song, Aijing; Nie, Jianhui; Zhang, Chuntao; Wang, Youchun

    2016-03-01

    A sophisticated regulatory framework has been constructed for Human immunodeficiency virus (HIV) diagnostics in China, which have developed over the past 30 years. China National Institutes for Food and Drug Control acts as the legal institution in this regulatory framework, launching important activities to ensure the quality of HIV diagnostics. These include the analysis of the main problems faced in developing domestic HIV diagnostics, by investigating the quality of HIV diagnostics and their development; exploring the key factors affecting the quality of HIV diagnostics, to determine the criteria for screening national reference samples; the development of new technologies and methods for preparing reference samples; and the establishment of nine types of national reference panels and nine national standards to evaluate the quality of HIV diagnostics. Based on these researches, a quality evaluation system was established, including nine types of national reference panels, nine national standards for HIV diagnostics, and five sample banks (HIV-positive sample bank, HIV-negative sample bank, common international genotype sample bank, seroconversion series sample bank, HIV virus bank) to evaluate the quality of HIV diagnostics in China. The regulatory framework and the quality evaluation system are pivotal in ensuring the quality of the HIV diagnostics licensed in China. Copyright © 2016 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  16. Diagnostic studies in amyloidosis

    NARCIS (Netherlands)

    Hazenberg, Bouke Pier Cornelis

    2007-01-01

    In this thesis two diagnostic techniques are studied in amyloidosis. Systemic amyloidosis is characterized by deposition of amyloid fibrils (tiny fibres) throughout the body resulting in damage of vital organs. Amyloid can be detected in a tissue specimen stained with Congo red: red-stained amyloid

  17. Angiography in renal diagnostics

    International Nuclear Information System (INIS)

    Schreyer, H.; Justich, E.; Graz Univ.

    1982-01-01

    The angiographic symptoms of kidney vessels diseases are described as well as traumas and growing and displacing processes of the kidneys. The diagnostic value of angiography in kidney traumas and growing and displacing processes of the kidney is discussed and compared with other techniques, e.g. urography, sonography and computed tomography. (orig.) [de

  18. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  19. Diagnostics for pellet experiments

    International Nuclear Information System (INIS)

    Johnson, R.R.

    1978-01-01

    The target diagnostics which are being used and planned in current laser driven ICF Experiments are described. Most of these diagnostics can be easily applied to future ion-beam fusion experiments. The status of laser fusion diagnostics has been much improved in the last 5 years and further improvements can be expected and should be available when the first ICF experiments using ion beams are performed. As an example, x-ray temporal and spatial resolutions are now approximately 5 psec and 3 μm, which is approximately a factor of 4 better than the resolution reported in the first implosion experiments. As one plans ahead for ion-beam fusion experiments it should be emphasized that high yield experiments are easier to diagnose provided adequate shielding is employed. However, in the event that the first high yield experiments fail it will be necessary to have diagnostics available to determine where the problems lie. In laser fusion it is interesting to note that higher laser powers are required now for breakeven experiments than first anticipated, mainly because some aspects of the laser-interaction physics were not recognized until the experiments were carefully diagnosed. Thus as has been pointed out, it may be necessary to increase the energy of the ion-beam driver to enable us to do breakeven experiments with high confidence

  20. 1968 Prototype Diagnostic Test.

    Science.gov (United States)

    Veterans Administration Hospital, Bedford, MA.

    This true-false diagnostic test was used for pretesting of employees at a Veterans Administration Hospital. The test is comprised of 20 items. An alternate test--Classification Questionnaire--was used for testing after remedial training. (For related document, see TM 002 334.) (DB)

  1. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  2. It's diagnostics, stupid.

    Science.gov (United States)

    Bernards, René

    2010-04-02

    To stem the spiraling cost of cancer treatment, a concerted effort is urgently needed to develop molecular diagnostics to better identify the patients that respond to expensive targeted therapies. Opportunities and obstacles in the development of such drug response biomarkers are discussed here. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Serbia : Systematic Country Diagnostic

    OpenAIRE

    World Bank Group

    2015-01-01

    This Systematic Country Diagnostic (SCD) aims to identify the major constraints on and opportunities for sustaining poverty reduction and shared prosperity in Serbia. The SCD serves as the analytic foundation on which the World Bank Group and the Government of Serbia will define a new Country Partnership Framework for FY2016 to FY2020. It is based on the best possible analysis, drawing on ...

  4. Diagnostic Vacuum Curettage

    African Journals Online (AJOL)

    1974-04-17

    Apr 17, 1974 ... A trial of the Vabra aspirator, a sterile disposable suction curette, was carried out on 136 outpatients. The apparatus is designed to allow full curettage of the uterine cavity. Adequate specimens for diagnostic histology were ob- tained in' all but 10 cases. Of these, no specimen was obtained in 4 cases.

  5. Microdosimetry of negative pions

    International Nuclear Information System (INIS)

    Amols, H.I.; Dicello, J.F.; Lane, T.F.

    1976-01-01

    The radiation quality of negative and positive pions of initial momentum 168MeV/c has been determined at eight different depths in a liquid phantom. The measurements were made with a 2.5cm diameter spherical proportional counter with Shonka A-150 neutron tissue equivalent plastic walls. The gas pressure in the sensitive volume was chosen to stimulate a diameter of 2μm in unit density material. Dose distributions as a function of lineal energy change slowly in the entrance and plateau regions with a dose mean lineal energy of 6-8keV/μm. Less than 3% of the dose is delivered in excess of 50keV/μm in this region. In the Bragg peak region the distributions change rapidly as a function of depth with the dose mean lineal energy increasing to 38keV/μm at the peak and to 57keV/μm just beyond the peak. On the basis of these microdosimetric data predictions of RBE and OER have been made with the use of both the theory of dual radiation action and also the delta ray theory of cell survival. The former has been used to predict biological response at low doses and the latter at high doses. A comparison is made between the two theories at intermediate doses. The results of these calculations are not inconsistant with recent biological data

  6. Cystic fibrosis of the pancreas with test of negative iontophoresis. Case study and literature revision

    International Nuclear Information System (INIS)

    Jaramillo B, Lina

    2000-01-01

    A case study is presented about a 6-month-old infant with repetitive respiratory symptoms. It is documented as cystic fibrosis, even though traditional diagnostic criteria are not met, such as a negative iontophoresis. The possible causes of this case are discussed, as well as diagnostic alternatives in these circumstances. Even though the iontophoresis test is negative the need to not eliminate this disease especially when the symptoms are very suspicious, is insisted greatly

  7. Status and challenges in electrical diagnostics of processing plasmas

    DEFF Research Database (Denmark)

    Stamate, Eugen

    2014-01-01

    electronegative so that, the role of negative ions cannot be neglected. The continuous decrease of the features size in micro- and nanoelectronic industry requires a precise control of plasma parameters including the negative ions. Despite of a good progress in plasma diagnostics, yet more is to be done...... of negative ions using the sheath-lens probe. The positive ion extraction from reactive plasmas is rather easy. However, this is not the case for negative ions. The influence of biased electrodes, of small or large dimensions on plasma parameters in electronegative discharges can give more information about...

  8. Meaning of the negative impedance

    Energy Technology Data Exchange (ETDEWEB)

    Conciauro, G.; Puglisi, M.

    1981-06-01

    It is shown that the negative real part of an input impedance does not mean instability of the related circuit. A negative real part of the input impedance means only that the concerned circuit is active.

  9. Meaning of the negative impedance

    International Nuclear Information System (INIS)

    Conciauro, G.; Puglisi, M.

    1981-06-01

    It is shown that the negative real part of an input impedance does not mean instability of the related circuit. A negative real part of the input impedance means only that the concerned circuit is active

  10. Negative index in chiral metamaterials

    OpenAIRE

    Singh, S.; Plum, E.; Menzel, C.; Rockstuhl, C.; Zheludev, N.; Zhang, W.

    2011-01-01

    We demonstrate that planar metamaterial lacking of mirror symmetry shows asymmetric transmission of terahertz waves and bands of positive, negative and zero phase and group velocities indicating a polarization sensitive negative index and slow-light media.

  11. Diagnostics of Factors of Enterprise Innovation Development

    Directory of Open Access Journals (Sweden)

    Skrynkovskyy Ruslan M.

    2017-03-01

    Full Text Available The aim of the article is the formation and development of theoretical and methodological foundations for diagnosing the factors of innovation development of an enterprise within the framework of theory and practice of economics and enterprise management. It was found out that the presented diagnostics should be understood as the process of identification, analysis and determination of the degree of influence of certain factors (positive, negative on the processes of innovative development of an enterprise in order to identify and solve problems (available, possible of hindering its innovation activity (introduction of new technological processes, innovative types of products, etc. in the context of ensuring an effective functioning and development of the enterprise. It is determined that the key business indicators of the system for diagnosing the factors of innovation development of an enterprise are indicators that reflect main factors of innovation development: indicator of innovation development; indicator of innovation activity of personnel; indicator of provision of the enterprise with intangible assets; indicator of the property required for innovative development; indicator of promotion of innovative products to the market. The prospect for further research in this scientific direction is developing a system of partial diagnostic purposes of a multicriteria system for diagnosing activities of enterprises with consideration for diagnostics of innovative development factors of the enterprise as a partial diagnostic purpose.

  12. The diagnostic value of liver biopsy

    Directory of Open Access Journals (Sweden)

    Zimmermann Arthur

    2001-10-01

    Full Text Available Abstract Background Since the introduction of molecular diagnostic tools such as markers for hepatitis C and different autoimmune diseases, liver biopsy is thought to be useful mainly for staging but not for diagnostic purposes. The aim was to review the liver biopsies for 5 years after introduction of testing for hepatitis C, in order to evaluate what diagnostic insights – if any – remain after serologic testing. Methods Retrospective review of all liver biopsies performed between 1.1.1995 and 31.12.1999 at an academic outpatient hepatology department. The diagnoses suspected in the biopsy note were compared with the final diagnosis arrived at during a joint meeting with the responsible clinicians and a hepatopathologist. Results In 365 patients, 411 diagnoses were carried out before biopsy. 84.4 % were confirmed by biopsy but in 8.8 %, 6.8 % and 10.5 % the diagnosis was specified, changed or a diagnosis added, respectively. Additional diagnoses of clinical relevance were unrecognized biliary obstruction and additional alcoholic liver disease in patients with chronic hepatitis C. Liver biopsy led to change in management for 12.1 % of patients. Conclusion Even in the era of advanced virological, immunological and molecular genetic testing, liver biopsy remains a useful diagnostic tool. The yield is particularly high in marker negative patients but also in patients with a clear-cut prebiopsy diagnosis, liver biopsy can lead to changes in patient management.

  13. Negative dimensional integrals. Pt. 1

    International Nuclear Information System (INIS)

    Halliday, I.G.; Ricotta, R.M.

    1987-01-01

    We propose a new method of evaluating integrals based on negative dimensional integration. We compute Feynman graphs by considering analytic extensions. Propagators are raised to negative integer powers and integrated over negative integer dimensions. We are left with the problem of computing polynomial integrals and summing finite series. (orig.)

  14. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  15. Negative chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Smit, A.L.C.

    1979-01-01

    This thesis describes some aspects of Negative Chemical Ionization (NCI) mass spectrometry. The reasons for the growing interest in NCI are: (i) to extend the basic knowledge of negative ions and their reactions in the gas phase; (ii) to investigate whether or not this knowledge of negative ions can be used successfully to elucidate the structure of molecules by mass spectrometry. (Auth.)

  16. FEL components and diagnostics

    International Nuclear Information System (INIS)

    Carr, R.

    1997-01-01

    FEL hardware includes undulators, alignment systems, electron beam diagnostics, and mechanical and vacuum systems. While most FEL close-quote s employ conventional undulators, there is some interest in novel types, particularly where conventional designs cannot be used, as at very short periods and high fields. For these areas, superconducting technology is indicated. The most serious issue facing long FEL undulators is that of alignment; mechanical techniques may not be accurate enough, and beam-based strategies must be considered. To maintain alignment and control the electron trajectory, beam position monitors with micron precision are required. Beam size monitors are also required to assure control of emittance. The talks given in the working group sessions touch on undulators, alignment, and electron beam diagnostics, and they are summarized here. copyright 1997 American Institute of Physics

  17. Bunched beam diagnostics

    International Nuclear Information System (INIS)

    Siemann, R.H.

    1989-01-01

    There is a remarkable diversity in the field of accelerator physics. Look at the proceedings of any conference. Papers range from Hamiltonian dynamics to the latest improvements of performance in accelerator X to the engineering of specialized equipment. Beam diagnostics is somewhere in the middle of this. Diagnostic instruments make the connection between theories and observations, and the capabilities of these instruments influence strongly our ability to improve performance. The gave a series of lectures in 1987 on the general topic of Principles of Beam Observation. The emphasis was on frequency domain analysis of beam generated signals in storage rings, and that is the subject of this paper. The goal is to connect spectrum analyzer observations to what the beam is doing. In addition, understanding beam spectra is essential for understanding coherent effects and instabilities in storage rings, and this is discussed extensively. 23 figures, 4 tables

  18. Nanobiosensors in diagnostics

    Directory of Open Access Journals (Sweden)

    Alejandro Chamorro-Garcia

    2016-11-01

    Full Text Available Medical diagnosis has been greatly improved thanks to the development of new techniques capable of performing very sensitive detection and quantifying certain parameters. These parameters can be correlated with the presence of specific molecules and their quantity. Unfortunately, these techniques are demanding, expensive, and often complicated. On the other side, progress in other fields of science and technology has contributed to the rapid growth of nanotechnology. Although being an emerging discipline, nanotechnology has raised huge interest and expectations. Most of the enthusiasm comes from new possibilities and properties of nanomaterials. Biosensors (simple, robust, sensitive, cost-effective combined with nanomaterials, also called nanobiosensors, are serving as bridge between advanced detection/diagnostics and daily/routine tests. Here we review some of the latest applications of nanobiosensors in diagnostics field.

  19. Nanodevices in diagnostics

    Science.gov (United States)

    Hu, Ye; Fine, Daniel H.; Tasciotti, Ennio; Bouamrani, Ali; Ferrari, Mauro

    2010-01-01

    The real-time, personalized and highly sensitive early-stage diagnosis of disease remains an important challenge in modern medicine. With the ability to interact with matter at the nanoscale, the development of nanotechnology architectures and materials could potentially extend subcellular and molecular detection beyond the limits of conventional diagnostic modalities. At the very least, nanotechnology should be able to dramatically accelerate biomarker discovery, as well as facilitate disease monitoring, especially of maladies presenting a high degree of molecular and compositional heterogeneity. This article gives an overview of several of the most promising nanodevices and nanomaterials along with their applications in clinical practice. Significant work to adapt nanoscale materials and devices to clinical applications involving large interdisciplinary collaborations is already underway with the potential for nanotechnology to become an important enabling diagnostic technology. PMID:20229595

  20. RFQ1 diagnostic devices

    International Nuclear Information System (INIS)

    Chidley, B.G.; Arbique, G.M.; de Jong, M.S.; McMichael, G.E.; Michel, W.L.; Smith, B.H.

    1991-01-01

    The diagnostic devices in use on RFQ1 will be described. They consist of a double-slit emittance-measuring unit, a 45 degree deflection energy-analysis magnet, parametric current transformers, optical beam sensors, beam-stop current monitors, and an x-ray end-point analyzer. All of these devices are able to operate up to the full output current of RFQ1 (75 mA cw at 0.6 MeV)

  1. Volumetric Combustion Diagnostics

    Science.gov (United States)

    2017-01-03

    Force Office of Scientific Research Submitted by: Lin Ma, PhD Professor Department of Aerospace and Ocean Engineering Department of Mechanical ...established PLIF (planar LIF [11, 12]) to volumetric measurement of species concentration, and have demonstrated single- shot VLIF measurements in both...Ikeda, J., Xu, W., Carter, C.D. Single Shot 3D Flame Diagnostic Based on Volumetric Laser Induced Fluorescence (VLIF), Proceedings of the

  2. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  3. SNS Diagnostics Timing Integration

    CERN Document Server

    Long, Cary D; Murphy, Darryl J; Pogge, James; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Windows XP Embedded for its OS and LabVIEW as its programming language. Coordinating timing among the various diagnostics instruments with the generation of the beam pulse is a challenging task that we have chosen to divide into three phases. First, timing was derived from VME based systems. In the second phase, described in this paper, timing pulses are generated by an in house designed PCI timing card installed in ten diagnostics PCs. Using fan-out modules, enough triggers were generated for all instruments. This paper describes how the Timing NAD (Network Attached Device) was rapidly developed using our NAD template, LabVIEW's PCI driver wizard, and LabVIEW Channel Access library. The NAD...

  4. XML Diagnostics Description Standard

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Varandas, C.; Lister, J.; Yonekawa, I.

    2006-01-01

    A standard for the self-description of fusion plasma diagnostics will be presented, based on the Extensible Markup Language (XML). The motivation is to maintain and organise the information on all the components of a laboratory experiment, from the hardware to the access security, to save time and money when problems arises. Since there is no existing standard to organise this kind of information, every Association stores and organises each experiment in different ways. This can lead to severe problems when the organisation schema is poorly documented or written in national languages. The exchange of scientists, researchers and engineers between laboratories is a common practice nowadays. Sometimes they have to install new diagnostics or to update existing ones and frequently they lose a great deal of time trying to understand the currently installed system. The most common problems are: no documentation available; the person who understands it has left; documentation written in the national language. Standardisation is the key to solving all the problems mentioned. From the commercial information on the diagnostic (component supplier; component price) to the hardware description (component specifications; drawings) to the operation of the equipment (finite state machines) through change control (who changed what and when) and internationalisation (information at least in the native language and in English), a common XML schema will be proposed. This paper will also discuss an extension of these ideas to the self-description of ITER plant systems, since the problems will be identical. (author)

  5. Diagnostic challenges in celiac disease

    Directory of Open Access Journals (Sweden)

    M Haghighat

    2014-04-01

    Full Text Available   1-The most important challenge in diagnosis of celiac disease is not- performing the diagnostic tests in suspected persons. Because of multi-organ damage and multiple manifestations of disease, diagnosis of celiac disease may be delayed. It seems general physicians should be awared about uncommon presentations of disease and indications of celiac tests 2-The second most important challenge is in patients with suspected disease but negative serologic tests. In these cases evaluating of HLA can be useful. 3- The third challenge is in cases with positive serologic tests but negative histopathological findings. There may be false positive serologic response or consumption of gluten before testing. We recommend introduction of gluten for at least 3 mo and re- endoscopy and if diagnosis is equivocal HLA-typing  for DQ8 and  DQ2 should be done. 4-The forth challenge is about performing endoscopy. Based on guideline from ESPGHAN if there are typical clinical manifestations of celiac disease, Anti-TTG more than ten times UPN , positive Anti-EMA and HLA DQ2, performing endoscopy may not be necessary, but many physicians don’t agree with this idea. 5-In people who are genetically predisposed to celiac disease antibody levels may be fluctuating thus endoscopy with biopsy should be done in these patients. 6-In children lower than 2years, Anti- TTG and Anti –EMA have low sensitivity. we recommend Anti-TTG and Anti-DGP in these patients. 7-Resolution of symptoms after gluten free diet is not necessarily a feature of celiac disease. This condition may be seen in patients with IBS or non-celiac gluten sensitivity.  

  6. An Ecological Diagnostic Classification Plan.

    Science.gov (United States)

    Hurst, James C.; McKinley, Donna L.

    1988-01-01

    Discusses the value of diagnostic classification systems to counseling professionals. Describes the Ecological Diagnostic Classification Plan, an approach to diagnosis that includes the environment as a possible cause of pathology and target of intervention. (Author/KS)

  7. Thioaptamer Diagnostic System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) will develop a diagnostic system in response to SBIR Topic X10.01 Reusable Diagnostic Lab Technology that will simultaneously detect and...

  8. The case for negative senescence

    DEFF Research Database (Denmark)

    Vaupel, James W; Baudisch, Annette; Dölling, Martin

    2004-01-01

    Negative senescence is characterized by a decline in mortality with age after reproductive maturity, generally accompanied by an increase in fecundity. Hamilton (1966) ruled out negative senescence: we adumbrate the deficiencies of his model. We review empirical studies of various plants and some...... kinds of animals that may experience negative senescence and conclude that negative senescence may be widespread, especially in indeterminate-growth species for which size and fertility increase with age. We develop optimization models of life-history strategies that demonstrate that negative senescence...

  9. Microbiological diagnostics of fungal infections

    Directory of Open Access Journals (Sweden)

    Corrado Girmenia

    2013-07-01

    Full Text Available Laboratory tests for the detection of fungal infections are easy to perform. The main obstacle to a correct diagnosis is the correlation between the laboratory findings and the clinical diagnosis. Among pediatric patients, the most common fungal pathogen is Candida. The detection of fungal colonization may be performed through the use of chromogenic culture media, which allows also the identification of Candida subspecies, from which pathogenicity depends. In neonatology, thistest often drives the decision to begin a empiric therapy; in this regard, a close cooperation between microbiologists and clinicians is highly recommended. Blood culture, if positive, is a strong confirmation of fungal infection; however, its low sensitivity results in a high percentage of false negatives, thus decreasing its reliability. Molecular diagnostics is still under evaluation, whereas the detection of some fungal antigens, such as β-D-glucan, galactomannan, mannoprotein, and cryptococcal antigen in the serum is used for adults, but still under evaluations for pediatric patients.http://dx.doi.org/10.7175/rhc.v4i1S.862

  10. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    Science.gov (United States)

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  11. Negative snakes in JET: evidence for negative shear

    International Nuclear Information System (INIS)

    Gill, R.D.; Alper, B.; Edwards, A.W.

    1994-01-01

    The signature of the negative snakes from the soft X-ray cameras is very similar to the more usual snakes except that the localised region of the snake has, compared with its surroundings, decreased rather than increased emission. Circumstances where negative snakes have been seen are reviewed. The negative snake appears as a region of increased resistance and of increased impurity density. The relationship between the shear and the current perturbation is shown, and it seem probable that the magnetic shear is reversed at the point of the negative snake, i.e. that q is decreasing with radius. 6 refs., 6 figs

  12. Diagnostic Evaluation of Pelvic Inflammatory Disease

    Directory of Open Access Journals (Sweden)

    Jeffrey F. Peipert

    1994-01-01

    An early and accurate diagnosis of PID is extremely important for the effective management of the acute illness and for the prevention of long-term sequelae. The diagnosis of PID is difficult, with considerable numbers of false-positive and false-negative diagnoses. An abnormal vaginal discharge or evidence of lower genital tract infection is an important and predictive finding that is often underemphasized and overlooked. This paper reviews the clinical diagnosis and supportive laboratory tests for the diagnosis of PID and outlines an appropriate diagnostic plan for the clinician and the researcher.

  13. Overview of ion source characterization diagnostics in INTF

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, M., E-mail: mainak@iter-india.org; Sudhir, Dass; Bhuyan, M.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A. [ITER-India, Institute for Plasma Research, A-29 GIDC, Sector-25, Gandhinagar, Gujarat 382016 (India); Soni, J. [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382 428 (India)

    2016-02-15

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  14. Planetary Transmission Diagnostics

    Science.gov (United States)

    Lewicki, David G. (Technical Monitor); Samuel, Paul D.; Conroy, Joseph K.; Pines, Darryll J.

    2004-01-01

    This report presents a methodology for detecting and diagnosing gear faults in the planetary stage of a helicopter transmission. This diagnostic technique is based on the constrained adaptive lifting algorithm. The lifting scheme, developed by Wim Sweldens of Bell Labs, is a time domain, prediction-error realization of the wavelet transform that allows for greater flexibility in the construction of wavelet bases. Classic lifting analyzes a given signal using wavelets derived from a single fundamental basis function. A number of researchers have proposed techniques for adding adaptivity to the lifting scheme, allowing the transform to choose from a set of fundamental bases the basis that best fits the signal. This characteristic is desirable for gear diagnostics as it allows the technique to tailor itself to a specific transmission by selecting a set of wavelets that best represent vibration signals obtained while the gearbox is operating under healthy-state conditions. However, constraints on certain basis characteristics are necessary to enhance the detection of local wave-form changes caused by certain types of gear damage. The proposed methodology analyzes individual tooth-mesh waveforms from a healthy-state gearbox vibration signal that was generated using the vibration separation (synchronous signal-averaging) algorithm. Each waveform is separated into analysis domains using zeros of its slope and curvature. The bases selected in each analysis domain are chosen to minimize the prediction error, and constrained to have the same-sign local slope and curvature as the original signal. The resulting set of bases is used to analyze future-state vibration signals and the lifting prediction error is inspected. The constraints allow the transform to effectively adapt to global amplitude changes, yielding small prediction errors. However, local wave-form changes associated with certain types of gear damage are poorly adapted, causing a significant change in the

  15. MAST magnetic diagnostics

    Science.gov (United States)

    Edlington, T.; Martin, R.; Pinfold, T.

    2001-01-01

    The mega-ampere spherical tokamak (MAST) experiment is a new, large, low aspect ratio device (R=0.7-0.8 m, a=0.5-0.65 m, maximum BT˜0.63 T at R=0.7 m) operating its first experimental physics campaign. Designed to study a wide variety of plasma shapes with up to 2 MA of plasma current with an aspect ratio down to 1.3, the poloidal field (PF) coils used for plasma formation, equilibrium and shaping are inside the main vacuum vessel. For plasma control and to investigate a wide range of plasma phenomena, an extensive set of magnetic diagnostics have been installed inside the vacuum vessel. More than 600 vacuum compatible, bakeable diagnostic coils are configured in a number of discrete arrays close to the plasma edge with about half the coils installed behind the graphite armour tiles covering the center column. The coil arrays measure the toroidal and poloidal variation in the equilibrium field and its high frequency fluctuating components. Internal coils also measure currents in the PF coils, plasma current, stored energy and induced currents in the mechanical support structures of the coils and graphite armour tiles. The latter measurements are particularly important when halo currents are induced following a plasma termination, for example, when the plasma becomes vertically unstable. The article describes the MAST magnetic diagnostic coil set and their calibration. The way in which coil signals are used to control the plasma equilibrium is described and data from the first MAST experimental campaign presented. These coil data are used as input to the code EFIT [L. Lao et al., Nucl. Fusion 25, 1611 (1985)], for measurement of halo currents in the vacuum vessel structure and for measurements of the structure of magnetic field fluctuations near the plasma edge.

  16. Bouveret's Syndrome: diagnostic considerations

    International Nuclear Information System (INIS)

    Cooper, S.G.; Sherman, S.B.; Steinhardt, J.E.; Wilson, J.M. Jr.; Richman, A.H.

    1987-01-01

    Bouveret's syndrome is a rare disease entity manifested by the formation of a cholecystoduodenal or choledochoduodenal fistula with passage of a gallstone into the duodenal bulb and subsequent obstruction of the gastric outlet. To date, no report of this entity using computed tomographic (CT) imaging is available. This article presents a case of Bouveret's syndrome with the classic findings on upper gastrointestinal (GI) tract series and a description of the CT manifestations. The literature is reviewed with discussion of the diagnostic approach to patients with Bouveret's syndrome

  17. COMPLEX RENAL MASSES DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    M.L. Chekhonatskaya

    2008-03-01

    Full Text Available Saratov State Medical University Research Institute for Fundamental and Clinical Urology Nephrology Renal masses are widespread pathology with high mortality and morbidity rate. Early diagnostics is a possibility of nephron-spearing surgery. Ultrasonography is screening imaging modality for renal lesions, Doppler investigation provide possibility for vascularity of these masses evaluation. CT with and without contrast enhancement can be used as a marker of malignancy. Magnetic resonance imaging has been proposed for the evaluation of renal lesions, especially in cases in which ultrasonography (US and/or CT results are not definitive.

  18. Dermatoglyphics: A Diagnostic Aid?

    Science.gov (United States)

    Fuller, I. C.

    1973-01-01

    Dermatoglyphics of patients suffering from diabetes, schizophrenia, duodenal ulcer, asthma, and various cancers have been contrasted and significant differences in the digital ridge counts, maximum atd angles, and distal palmar loop ridge counts have been found. A discriminant analysis of the digital ridge counts was performed and the function was used to attempt differential diagnosis between these conditions on dermatoglyphic evidence alone. This diagnostic trial failed, and possible reasons for its failure are discussed. Attention is drawn to the possibility that prognostic implications of dermatoglyphics might be relevant to screening techniques. PMID:4714584

  19. FASTBUS Snoop Diagnostic Module

    International Nuclear Information System (INIS)

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table

  20. Isotope diagnostics apparatus

    International Nuclear Information System (INIS)

    Herrschaft, H.

    1976-01-01

    The invention relates to a measuring probe for an isotope diagnostics apparatus to determine the distribution of radioactive substances in a body by measuring the radiation emanating from this body by means of a multiplicity of measuring probes directed simultaneously towards areas of measuring surfae and carried in guidances of a holding block. The measuring results of the individual probes are recorded separately, thus allowing the possibility of being evaluated separately, too. Measuring probes of this kind are used in multi-channel measuring objects and are useful particularly for determining the regional cerebral blood flow. (orig./ORU) [de

  1. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  2. Negative Attitudes, Network and Education

    DEFF Research Database (Denmark)

    Bennett, Patrick; la Cour, Lisbeth; Larsen, Birthe

    use Danish register data to find a signficant positive correlation between negative attitudes towards immigrants and high school attendance and find a positive impact of networking on high school attendance. In both the macro and the micro-econometric analysis we run the same regressions for natives......We consider the impact of negative attitudes against immigrants and immigration on educational choice in a search and wage bargaining model including networking. We consider two cases in terms of the importance of negative attitudes againts immigrants for high and low educated individuals and find...... that more negative attitudes against immigrants has a positive impact on education in one case and a negative impact in the other and has no impact on natives. Immigration improves employment perspectives for immigrants and thereby increases immigrant education whereas endogenous negative attitudes lead...

  3. Wages, Amenities and Negative Attitudes

    DEFF Research Database (Denmark)

    Waisman, Gisela; Larsen, Birthe

    We exploit the regional variation in negative attitudes towards immigrants to Sweden in order to analyse the consequences of the attitudes on immigrants welfare. We find that attitudes towards immigrants are of importance: they both affect their labour market outcomes and their quality of life. We...... interpret the negative effect on wages as evidence of labour market discrimination. We estimate the welfare effects of negative attitudes, through their wage and local amenities, for immigrants with different levels of skills, origin, gender and age....

  4. On Negation as Mitigation: The Case of Negative Irony

    Science.gov (United States)

    Giora, Rachel; Fein, Ofer; Ganzi, Jonathan; Levi, Natalie Alkeslassy; Sabah, Hadas

    2005-01-01

    Four experiments support the view of negation as mitigation (Giora, Balaban, Fein, & Alkabets, 2004). They show that when irony involves some sizable gap between what is said and what is criticized (He is exceptionally bright said of an idiot), it is rated as highly ironic (Giora, 1995). A negated version of that overstatement (He is not…

  5. NEGATIVITY AND POSITIVITY EFFECTS IN PERSON PERCEPTION AND INFERENCE : ABILITY VERSUS MORALITY

    NARCIS (Netherlands)

    MARTIJN, C; SPEARS, R; VAN DER PLIGT, J; JAKOBS, E

    1992-01-01

    The present paper deals with negativity and positivity effects in trait inferences and impression formation. In the first experiment we tested the suggestion of Skowronski and Carlston (1987) that in the domain of morality negative information is more diagnostic, will therefore receive more weight

  6. Diagnostic Bias and Conduct Disorder: Improving Culturally Sensitive Diagnosis

    Science.gov (United States)

    Mizock, Lauren; Harkins, Debra

    2011-01-01

    Disproportionately high rates of Conduct Disorder are diagnosed in African American and Latino youth of color. Diagnostic bias contributes to overdiagnosis of Conduct Disorder in these adolescents of color. Following a diagnosis of Conduct Disorder, adolescents of color face poorer outcomes than their White counterparts. These negative outcomes…

  7. Metabolic markers as possible diagnostic tools to distinguish ...

    African Journals Online (AJOL)

    No metabolic markers could distinguish between gram positive and gram negative septicemia. α-Amino-adipic acid, citramalic acid and xanthurenic acid, produced only by bacteria, show promise. Alanine and glycine increased significantly over 24 h and can be used as diagnostic markers and perhaps as markers of ...

  8. Intense negative heavy ion sources

    Science.gov (United States)

    Mori, Yoshiharu; Takagi, Akira; Ikegami, Kiyoshi; Ueno, Akira; Fukumoto, Sadayoshi

    1990-08-01

    Negative ion sources based on plasma-surface interactions (BLAKE ion source) have been developed at KEK for producing negative heavy ions. The first negative heavy ion source (BLAKE-II) was developed by modifying the ordinary negative hydrogen ion source with converter (BLAKE-I) placed into the plasma. It generates various species of negative heavy ions with intense beam currents. For example, a more than 10 mA Au- ion beam was obtained from the ion source. Recently, the large scaled negative heavy ion source (BLAKE-III) has been developed and in the preliminary test experiment, more than 100 mA Cu- ion beam has been stably obtained with a 10% duty factor in pulsed operation. The BLAKE-II ion source was attached to the BNL 15 MV and Tsukuba University TANDEM accelerators and large current negative heavy ion beams were successfully accelerated in pulsed mode operation. Also, it was found that the space charge effect should be carefully considered for such a large current acceleration in a tandem accelerator, especially at the injection beam line and low energy end. In order to examine the negative ion formation process fundamentally, negative ion production probability related on sputtered particle velocity was measured and the results showed exponential dependence of the production probability on particle velocity as Norskov and Lindquist's theory predicted.

  9. Prestarlike functions with negative coefficients

    Directory of Open Access Journals (Sweden)

    H. Silverman

    1979-01-01

    Full Text Available The extreme points for prestarlike functions having negative coefficients are determined. Coefficient, distortion and radii of univalence, starlikeness, and convexity theorems are also obtained.

  10. Negative ions of polyatomic molecules

    International Nuclear Information System (INIS)

    Christophorou, LG.

    1980-01-01

    In this paper general concepts relating to, and recent advances in, the study of negative ions of polyatomic molecules are discussed with emphasis on halocarbons. The topics dealt with in the paper are as follows: basic electron attachment processes, modes of electron capture by molecules, short-lived transient negative ions, dissociative electron attachment to ground-state molecules and to hot molecules (effects of temperature on electron attachment), parent negative ions, effect of density, nature, and state of the medium on electron attachment, electron attachment to electronically excited molecules, the binding of attached electrons to molecules (electron affinity), and the basic and the applied significance of negative-ion studies

  11. Helicobacter pylori infection: a simplified diagnostic approach.

    Science.gov (United States)

    Conti-Nibali, S; Sferlazzas, C; Fera, M T; Saitta, G; Tedeschi, A; Magazzù, G

    1990-12-01

    We evaluated the diagnostic accuracy of endoscopic finding of nodular antritis and rapid urease test (RUT) in order to simplify the approach to the diagnosis of Helicobacter pylori (H. pylori) infection. Forty-four consecutive patients (mean age 7.9 yr, range 6-13 yr) referred because of recurrent abdominal pain as the main symptom, were prospectively investigated for the presence of H. pylori. H. pylori positivity or negativity was defined as the concordance of two of the following tests: RUT, microbiologic culture, and histologic examination on bioptic samples. RUT sensitivity was 100%, whereas specificity was 87.5%. The presence of nodular antritis had a sensitivity of 96.4% and specificity of 87.5% in H. pylori infection diagnosis. The predictivity value of combined RUT and nodular antritis, whether positive or negative, was 100%. Only in case of discordance do we suggest the utilization of other expensive tools for diagnosis of H. pylori infection.

  12. Diagnostic Technologies in Practice

    Science.gov (United States)

    Steinberg, Malcolm; Kwag, Michael; Chown, Sarah A.; Doupe, Glenn; Trussler, Terry; Rekart, Michael; Gilbert, Mark

    2015-01-01

    Diagnosing HIV-positive gay men through enhanced testing technologies that detect acute HIV infection (AHI) or recent HIV infection provides opportunities for individual and population health benefits. We recruited 25 men in British Columbia who received an acute (n = 13) or recent (n = 12) HIV diagnosis to engage in a longitudinal multiple-methods study over one year or longer. Our thematic analysis of baseline qualitative interviews revealed insights within men’s accounts of technologically mediated processes of HIV discovery and diagnosis. Our analysis illuminated the dialectic of new HIV technologies in practice by considering the relationship between advances in diagnostics (e.g., nucleic acid amplification tests) and the users of these medical technologies in clinical settings (e.g., clients and practitioners). Technological innovations and testing protocols have shifted experiences of learning of one’s HIV-positive status; these innovations have created new diagnostic categories that require successful interpretation and translation to be rendered meaningful, to alleviate uncertainty, and to support public health objectives. PMID:25201583

  13. Radiation hardening of diagnostics

    International Nuclear Information System (INIS)

    Siemon, R.E.

    1991-01-01

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10 16 neutrons per second because of ''spallation'' reactions when the protons collide with the copper nuclei in the beam stop

  14. Reflectometry diagnostics on TCV

    Science.gov (United States)

    Molina Cabrera, Pedro; Coda, Stefano; Porte, Laurie; Offeddu, Nicola; Tcv Team

    2017-10-01

    Both profile reflectometer and Doppler back-scattering (DBS) diagnostics are being developed for the TCV Tokamak using a steerable quasi-optical launcher and universal polarizers. First results will be presented. A pulse reflectometer is being developed to complement Thomson Scattering measurements of electron density, greatly increasing temporal resolution and also effectively enabling fluctuation measurements. Pulse reflectometry consists of sending short pulses of varying frequency and measuring the roundtrip group-delay with precise chronometers. A fast arbitrary waveform generator is used as a pulse source feeding frequency multipliers that bring the pulses to V-band. A DBS diagnostic is currently operational in TCV. DBS may be used to infer the perpendicular velocity and wave number spectrum of electron density fluctuations in the 3-15 cm-1 wave-number range. Off-the-shelf transceiver modules, originally used for VNA measurements, are being used in a Doppler radar configuration. See author list of S. Coda et al., 2017 Nucl. Fusion 57 102011.

  15. Shiva optical diagnostics

    International Nuclear Information System (INIS)

    Rienecker, F.; Kobierecki, M.; Ozarski, R.; Seppala, L.; Manes, K.; Merritt, B.

    1977-01-01

    In the laser fusion program at Lawrence Livermore Laboratory, no target experiment is complete unless it is complemented by careful measurements of the laser pulse that irradiates the target. For this purpose, an incident beam diagnostics (IBD) package has been designed for the Shiva laser. The package will furnish data on items such as the total energy and the focusable energy out of the laser chain, and the spatial and temporal energy and power distribution at the target plane. Understanding laser-plasma interactions requires knowledge of the amount of 1.06 μm light energy that is scattered in various directions from the target. The light energy that is scattered toward the beam focusing lens is analyzed by a reflected beam diagnostic (RBD) package containing a calorimeter, a multiple image camera and a TV camera. This paper describes the detailed design and operation of the IBD and RBD packages as tools to align spatial filters and targets, as well as to diagnose the laser beams and target reflectivity

  16. Encyclopedia of diagnostic imaging

    International Nuclear Information System (INIS)

    Baert, A.L.

    2008-01-01

    The simple A to Z format provides easy access to relevant information in the field of imaging. Extensive cross references between keywords and related articles enable efficient searches in a user-friendly manner. Fully searchable and hyperlinked electronic online edition. The aim of this comprehensive encyclopedia is to provide detailed information on diagnostic radiology contributing to the broad field of imaging. The wide range of entries are written by leading experts. They will provide basic and clinical scientists in academia, practice and industry with valuable information about the field of diagnostic imaging. Those in related fields, students, teachers, and interested laypeople will also benefit from the important and relevant information on the most recent developments. Please note that this publication is available as print only or online only or print + online set. Save 75% of the online list price when purchasing the bundle. For more information on the online version please type the publication title into the search box above, then click on the eReference version in the results list. (orig.)

  17. Radiation hardening of diagnostics

    Science.gov (United States)

    Siemon, R. E.

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10(exp 16) neutrons per second because of spallation'reactions when the protons collide with the copper nuclei in the beam stop.

  18. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    The current status of the capability of laser fusion diagnostics is reviewed. Optical and infrared streak cameras provide one time resolution measurement capability of less than 10 ps, while x-ray streak cameras provide 15 ps time resolution in the range of about 1--30 keV presently. Time integrated spatial resolutions of 1 μm are provided with a variety of optical techniques. Ultraviolet holographic interferometry has measured electron densities above 10 21 cm -3 with 1 μm spatial resolution and 15 ps temporal resolution. X-ray microscopes provide 3 μm time integrated resolution and the x-ray streak pinhole camera has 6 μm spatial resolution. Development of the framing camera has thus far provided 50 μm spatial resolution with 125 ps frame duration and the third order reconstruction of zone plate images has provided 3 μm resolutions for alpha particles. Time integrated measurements of x-rays span the range shown. Finally, the new Shiva neutron spectrometer increases the energy resolution capability of that technique to 25 keV for 14-MeV neutrons. These combined capabilities provide a unique set of diagnostics for the detailed measurement of the interaction of laser light with targets and a subsequent performance of those targets

  19. Instrumentation and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Nakaishi, C.V.; Bedick, R.C.

    1990-12-01

    This Technology Status Report describes research and accomplishments for the Instrumentation and Diagnostics (I D) Projects within the Advanced Research and Technology Development (AR TD) Program of the United States Department of Energy (DOE) Office of Fossil Energy (FE). Process understanding and control can be improved through the development of advanced instrumentation and diagnostics. The thrust of the I D Projects is to further develop existing measurement and control techniques for application to advanced coal-based technologies. Project highlights are: an inductively coupled plasma (ICP) instrument has been developed to analyze trace elements in gasification and combustion process streams. An in situ two-color Mie scattering technique with LSS can simultaneously measure the size, velocity, and elemental composition of coal particles during combustion. A high-temperature, fluorescence thermometry technique has accurately measured gas temperatures during field testing in combustion and gasification environments. Expert systems have been developed to improve the control of advanced coal-based processes. Capacitance flowmeters were developed to determine the mass flowrate, solid volume fraction, and particle velocities of coal slurries. 32 refs., 9 figs.

  20. Diagnostic algorithm for syncope.

    Science.gov (United States)

    Mereu, Roberto; Sau, Arunashis; Lim, Phang Boon

    2014-09-01

    Syncope is a common symptom with many causes. Affecting a large proportion of the population, both young and old, it represents a significant healthcare burden. The diagnostic approach to syncope should be focused on the initial evaluation, which includes a detailed clinical history, physical examination and 12-lead electrocardiogram. Following the initial evaluation, patients should be risk-stratified into high or low-risk groups in order to guide further investigations and management. Patients with high-risk features should be investigated further to exclude significant structural heart disease or arrhythmia. The ideal currently-available investigation should allow ECG recording during a spontaneous episode of syncope, and when this is not possible, an implantable loop recorder may be considered. In the emergency room setting, acute causes of syncope must also be considered including severe cardiovascular compromise due to pulmonary, cardiac or vascular pathology. While not all patients will receive a conclusive diagnosis, risk-stratification in patients to guide appropriate investigations in the context of a diagnostic algorithm should allow a benign prognosis to be maintained. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. [Companion diagnostics and reimbursement system].

    Science.gov (United States)

    Tazawa, Yoshiaki

    2013-05-01

    Recently, Companion Diagnostics (CoDx) have been gaining importance to promote personalized medicine in order to improve the safety and cost effectiveness of therapy. In July 2011, the FDA published draft guidance for the development of CoDx, which recommends the co-development of CoDx and new drugs as the best practice, and then the FDA approved vemurafenib and the BRAF-V600-E gene mutation assay simultaneously as a typical example of the co-development of a new drug and its CoDx. Considering medical needs for multiple biomarker assays to select the right assay from various therapeutic candidates, more complicated assay technologies such as DNA sequencing will be required for CoDx in the near future. However, since it is quite difficult to standardize the validation process and manage test quality under the current regulatory criteria of in-vitro diagnostics using advanced and/or complicated assay technologies, the clinical use of laboratory-developed tests (LDT) should be recommended in order to avoid biomarker test lag. On the other hand, the current reimbursement system is not always suitable to assess the clinical and technological value of CoDx and it should be revised to encourage the development of CoDx. Although Health Technology Assessment (HTA) is a potential method to assess the value of CoDx, it is not easy to define appropriate indicators for CoDx because its clinical utility and cost effectiveness are completely dependent on the performance and value of available therapy. It is also suggested that the price and/or insurance rate of CoDx should be included in the price of the drug; however, there is no good solution to how to pay for CoDx with negative results for all therapies. It is said that the concept of personalized medicine with advanced technologies is a destructive innovation that could markedly change the current structure and system of medications; therefore, it is essential to create a quite new regulatory and reimbursement system to

  2. A new method for analyzing diagnostic delay in gynecological cancer

    DEFF Research Database (Denmark)

    Vandborg, Mai Partridge; Edwards, Kasper; Kragtrup, Jakob

    2012-01-01

    OBJECTIVE: The aim of this article is to present a new methodology to illustrate, understand, and measure delay in health care. The method is inspired by process mapping tools as analytical framework and demonstrates its usefulness for studying diagnostic delay in gynecological cancer. MATERIALS...... to responsibilities and was shown to recurrently influence and contribute to the delay in the diagnostic process. Some important contributors to diagnostic delay in gynecological cancer, such as lack of cancer suspicion, competing diseases, negative test results, inexpedient referral patterns, and referrals without...... cancer suspicion, were found. CONCLUSIONS: Our results point out process mapping tools as a potential analytical framework to illustrate, understand, and measure delay in health care. Furthermore, the method was able to identify important contributors to the diagnostic delay in gynecological cancer...

  3. Diagnostic Value of Nasopharyngeal Aspirates in Children with Lower Respiratory Tract Infections

    Directory of Open Access Journals (Sweden)

    Ai-Zhen Lu

    2017-01-01

    Conclusions: NPAs are less invasive diagnostic respiratory specimens, a negative NPA result is helpful in “rule out” lower airway infection; however, a positive result does not reliably “rule in” the presence of pathogens.

  4. Diagnostic Labels, Stigma, and Participation in Research Related to Dementia and Mild Cognitive Impairment

    OpenAIRE

    Garand, Linda; Lingler, Jennifer H.; Conner, Kyaien O.; Dew, Mary Amanda

    2009-01-01

    Health care professionals use diagnostic labels to classify individuals for both treatment and research purposes. Despite their clear benefits, diagnostic labels also serve as cues that activate stigma and stereotypes. Stigma associated with the diagnostic labels of dementia and mild cognitive impairment (MCI) can have a significant and negative impact on interpersonal relationships, interactions with the health care community, attitudes about service utilization, and participation in clinica...

  5. Double-Negative Mechanical Metamaterials Displaying Simultaneous Negative Stiffness and Negative Poisson’s Ratio Properties

    OpenAIRE

    Hewage, Trishan A.M.; Alderson, Kim L; Alderson, Andrew; Scarpa, Fabrizio

    2016-01-01

    Intuitively, materials become both shorter and wider when compressed along their length. Here we show how a composite material or structure can display a simultaneous reversal in the direction of deformation for both the axial and transverse dimensions, corresponding to negative values of effective stiffness and effective Poisson’s ratio, respectively. A negative Poisson’s ratio[1] (NPR or auxetic[2]) host assembly stabilising (otherwise unstable) embedded negative stiffness[3] (NS) elements ...

  6. Negative supervisionsoplevelser og deres konsekvenser

    DEFF Research Database (Denmark)

    Nielsen, Jan

    2011-01-01

    in evaluation. First part of the paper explores negative experience in supervision in general. The second part, focusing on negative experience in supervision caused by evaluation, is explored and discussed in relation to the key concept of supervisory alliance (Bordin, 1983), perceiving evaluation...

  7. Research priorities for negative emissions

    NARCIS (Netherlands)

    Fuss, S.; Jones, C. D.; Kraxner, F.; Peters, G. P.; Smith, P.; Tavoni, M.; van Vuuren, Detlef; Canadell, J. G.; Jackson, R. B.; Milne, J.; Moreira, J. R.; Nakicenovic, N.; Sharifi, A.; Yamagata, Y.

    2016-01-01

    Carbon dioxide removal from the atmosphere (CDR) - also known as 'negative emissions' - features prominently in most 2 °C scenarios and has been under increased scrutiny by scientists, citizens, and policymakers. Critics argue that 'negative emission technologies' (NETs) are insufficiently mature to

  8. Income, Amenities and Negative Attitudes

    DEFF Research Database (Denmark)

    Waisman, Gisela; Larsen, Birthe

    2016-01-01

    We exploit the regional variation in negative attitudes towards immigrants to Sweden in order to analyse the consequences of negative attitudes on refugees’ utility from labour income and amenities. We find that attitudes towards immigrants are important: while they affect mainly the refugees...

  9. Question tags and sentential negativity

    NARCIS (Netherlands)

    Brasoveanu, A.; De Clercq, K.; Farkas, D.; Roelofsen, F.

    2014-01-01

    This paper presents an experiment that is designed to quantify the negativity of sentences with different types of negative operators (n-words like never and downward entailing operators like rarely) in different syntactic positions (adverb, subject, and direct object). In the experiment,

  10. Evaluation of the appendix during diagnostic laparoscopy, the laparoscopic appendicitis score : a pilot study

    NARCIS (Netherlands)

    Hamminga, Jenneke T. H.; Hofker, H. Sijbrand; Broens, Paul M. A.; Kluin, Philip M.; Heineman, Erik; Haveman, Jan Willem

    Diagnostic laparoscopy is the ultimate diagnostic tool to evaluate the appendix. Still, according to the literature, this strategy results in a negative appendectomy rate of approximately 12-18 % and associated morbidity. Laparoscopic criteria for determining appendicitis are lacking. The goal of

  11. Revisited diagnostics of hereditary epidermolysis bullosa

    Directory of Open Access Journals (Sweden)

    V. I. Albanova

    2014-01-01

    Full Text Available Hereditary epidermolysis bullosa is a big group of hereditary diseases with the main manifestations in the form of blisters on the skin and mucous coat after slight mechanical injuries. It is not always possible to diagnose this disease based on the clinical picture. The article discusses current laboratory diagnostics methods for hereditary epidermolysis bullosa including immunofluorescence antigen mapping (IFM, transmission electron microscopy (TEM and genetic analysis (molecular or DNA diagnostics as well as their advantages and disadvantages. TEM determines the micro splitting level and nature of ultrafine changes in the area of the dermoepidermal junction; at the same time, such tests need special expensive equipment. Substantial experience is also needed to analyze the resulting submicroscopic images. IFM determines whether expression of the affected protein related to the disease development is reduced or absent; however, invalid (false positive or false negative results can be obtained in patients with the reduced expression of the affected protein. Genetic analysis plays a key role for prenatal diagnostics. Therefore, to make an exact diagnosis of hereditary epidermolysis bullosa, it is expedient to apply IFM, TEM and genetic analysis. The need to set an exact diagnosis of the disease is related to the fact that the promising treatment methods being currently developed are aimed at treating patients with certain forms of the disease.

  12. Component-resolved diagnostics in vernal conjunctivitis.

    Science.gov (United States)

    Armentia, Alicia; Sanchís, Eugenia; Montero, Javier A

    2016-10-01

    Conventional diagnostic tests in allergy are insufficient to clarify the cause of vernal conjunctivitis. Component-resolved diagnostic (CRD) by microarray allergen assay may be useful in detecting allergens that might be involved in the inflammatory process. In a recent trial in patients suffered from eosinophilic esophagitis, after 2 years of the CRD-guided exclusion diet and specific immunotherapy, significant clinical improvement was observed, and 68% of patients were discharged (cure based on negative biopsy, no symptoms, and no medication intake). Our new objective was to evaluate IgE-mediated hypersensitivity by CRD in tears and serum from patients with vernal conjunctivitis and treat patients with identified triggering allergens by specific immunotherapy. Twenty-five patients with vernal conjunctivitis were evaluated. The identified triggering allergens were n Lol p 1 (11 cases), n Cyn d 1 (eight cases), group 4 and 6 grasses (six cases) and group 5 of grasses (five cases). Prick test and pollen IgE were positive in one case. Clinical improvement was observed in 13/25 vernal conjunctivitis patients after 1-year specific immunotherapy. CRD seems to be a more sensitive diagnostic tool compared with prick test and IgE detection. Specific CRD-led immunotherapy may achieve clinical improvements in vernal conjunctivitis patients.

  13. Diagnostic Challenges at SNS

    CERN Document Server

    Plum, M A

    2003-01-01

    The Spallation Neutron Source now being built in Oak Ridge, Tennessee, USA, accelerates an H- ion beam to 1000 MeV with an average power of 1.4 MW. The H- beam is then stripped to H+, compressed in a storage ring to a pulse length of 695 ns, and then directed onto a mercury neutron spallation target. Most of the acceleration is accomplished with superconducting rf cavities. The presence of these cavities, the high average beam power, and the large range of beam intensity in the storage ring, provide unique challenges to the beam diagnostics systems. In this talk we will discuss these challenges and some of our solutions, including the laser profile monitor system, the residual gas ionization profile monitors, and network attached devices. Measurements performed using prototype instrumentation will also be presented.

  14. Laboratory Diagnostics for Histoplasmosis.

    Science.gov (United States)

    Azar, Marwan M; Hage, Chadi A

    2017-06-01

    The diagnosis of histoplasmosis is based on a multifaceted approach that includes clinical, radiographic, and laboratory evidence of disease. The gold standards for laboratory diagnosis include demonstration of yeast on pathological examination of tissue and isolation of the mold in the culture of clinical specimens; however, antigen detection has provided a rapid, noninvasive, and highly sensitive method for diagnosis and is a useful marker of treatment response. Molecular methods with improved sensitivity on clinical specimens are being developed but are not yet ready for widespread clinical use. This review synthesizes currently available laboratory diagnostics for histoplasmosis, with an emphasis on complexities of testing and performance in various clinical contexts. Copyright © 2017 American Society for Microbiology.

  15. Oral vs. salivary diagnostics

    Science.gov (United States)

    Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel

    2015-05-01

    The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.

  16. Molecular diagnostic PCR handbook

    International Nuclear Information System (INIS)

    Viljoen, G.J.; Crowther, J.R.; Nel, L.H.

    2005-01-01

    The uses of nucleic acid-directed methods have increased significantly in the past five years and have made important contributions to disease control country programmes for improving national and international trade. These developments include the more routine use of PCR as a diagnostic tool in veterinary diagnostic laboratories. However, there are many problems associated with the transfer and particularly, the application of this technology. These include lack of consideration of: the establishment of quality-assured procedures, the required set-up of the laboratory and the proper training of staff. This can lead to a situation where results are not assured. This book gives a comprehensive account of the practical aspects of PCR and strong consideration is given to ensure its optimal use in a laboratory environment. This includes the setting-up of a PCR laboratory; Good Laboratory Practice and standardised PCR protocols to detect animal disease pathogens. Examples of Standard Operating Procedures as used in individual specialist laboratories and an outline of training materials necessary for PCR technology transfer are presented. The difficulties, advantages and disadvantages in PCR applications are explained and placed in context with other test systems. Emphasis is placed on the use of PCR for detection of pathogens, with a particular focus on diagnosticians and scientists from the developing world. It is hoped that this book will enable readers from various disciplines and levels of expertise to better judge the merits of PCR and to increase their skills and knowledge in order to assist in a more logical, efficient and assured use of this technology

  17. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  18. Postpartum Tuberculosis: A Diagnostic and Therapeutic Challenge

    Directory of Open Access Journals (Sweden)

    Vijay Kodadhala

    2016-01-01

    Full Text Available Tuberculosis (TB infection in pregnant women and newborn babies is always challenging. Appropriate treatment is pivotal to curtail morbidity and mortality. TB diagnosis or exposure to active TB can be emotionally distressing to the mother. Circumstances can become more challenging for the physician if the mother’s TB status is unclear. Effective management of TB during pregnancy and the postpartum period requires a multidisciplinary approach including pulmonologist, obstetrician, neonatologist, infectious disease specialist, and TB public health department. Current guidelines recommend primary Isoniazid prophylaxis in TB exposed pregnant women who are immune-suppressed and have chronic medical conditions or obstetric risk factors and close and sustained contact with a patient with infectious TB. Treatment during pregnancy is the same as for the general adult population. Infants born to mothers with active TB at delivery should undergo a complete diagnostic evaluation. Primary Isoniazid prophylaxis for at least twelve weeks is recommended for those with negative diagnostic tests and no evidence of disease. Repeated negative diagnostic tests are mandatory before interrupting prophylaxis. Separation of mother and infant is only necessary when the mother has received treatment for less than 2 weeks, is sputum smear-positive, or has drug-resistant TB. This case highlights important aspects for management of TB during the postpartum period which has a higher morbidity. We present a case of a young mother migrating from a developing nation to the USA, who was found to have a positive quantiFERON test associated with multiple cavitary lung lesions and gave birth to a healthy baby.

  19. Isotropic Negative Thermal Expansion Metamaterials.

    Science.gov (United States)

    Wu, Lingling; Li, Bo; Zhou, Ji

    2016-07-13

    Negative thermal expansion materials are important and desirable in science and engineering applications. However, natural materials with isotropic negative thermal expansion are rare and usually unsatisfied in performance. Here, we propose a novel method to achieve two- and three-dimensional negative thermal expansion metamaterials via antichiral structures. The two-dimensional metamaterial is constructed with unit cells that combine bimaterial strips and antichiral structures, while the three-dimensional metamaterial is fabricated by a multimaterial 3D printing process. Both experimental and simulation results display isotropic negative thermal expansion property of the samples. The effective coefficient of negative thermal expansion of the proposed models is demonstrated to be dependent on the difference between the thermal expansion coefficient of the component materials, as well as on the circular node radius and the ligament length in the antichiral structures. The measured value of the linear negative thermal expansion coefficient of the three-dimensional sample is among the largest achieved in experiments to date. Our findings provide an easy and practical approach to obtaining materials with tunable negative thermal expansion on any scale.

  20. Team building and diagnostic training

    International Nuclear Information System (INIS)

    Bulmer, S.

    1987-01-01

    While developing a commercial training program to improve teamwork in control room crews, General Electric's Nuclear Training Services made an important discovery. Traditional training methods for developing teamwork and enhancing diagnostics capabilities are incomplete. Traditional methods generally help, but fail to fulfill the long-term needs of most teams. Teamwork has been treated as a short-term performance problem. Traditional diagnostic training suffers from a similar problem. Too often, it covers only the basic principles of decision-making, ignoring the development of expert diagnostic capabilities. In response to this discovery, they have developed comprehensive training in Team Building and Diagnostics

  1. Evaluation of radiological detriment from negative radiological examinations

    International Nuclear Information System (INIS)

    Frometa Suarez, I.; Jerez Vergueria, S.F.

    1997-01-01

    The individul doses of radiation due to diagnostic radiology are usually low, though their contribution to the collective dose is very important given the large numbers of people exposed to these. This paper presents an analysis of the number of negative radiologiacl examinations in a major Cuban Hospital, and their contribution to the collective dose, and radiation organ and tissue, effective (expressed as severe hereditary effect and the occurrence of fatal and non fatal cancers) are all evaluated. The negative findings constitute 41 % of all examinations. The total contribution of negative examinations to the collective dose is very important given the large numbers of people exposed to these. This papaer presents an analysis of the number of negative radiological examinations in major Cuban Hospital, and their contribution to the collective dose of radiation. The absorbed dose by irradiation organ and tissue, effective dose equivalent, collective dose, and radiation risk (expressed as severe herditary effect and the occureence of fatal and non fatal cancers) are all evaluated. The negative findings constitute 41% of all examinations. The total contribution of negative examinations. The total contribution of negative examinations to the collective dose are found to make up 52.9 %: 11.35 Sv-man in the studied population

  2. Negative Attitudes, Network and Education

    DEFF Research Database (Denmark)

    Bennett, Patrick; la Cour, Lisbeth; Larsen, Birthe

    This paper explores potential explanations behind the educational gap between young natives and immigrants using two measures, negative attitudes towards immigrants and networking, which may influence natives and immigrants differently. The paper considers, both theoretically and empirically......, the impact of negative attitudes and networking taking into account that these parameters may influence high and uneducated workers as well as immigrants and natives differently, creating different incentives to acquire education for the two ethnic groups. Using rich Danish administrative data, this paper...... finds evidence that greater negative attitudes increase incentives for males to acquire education and that networking also increases immigrant education....

  3. Mazindol treatment of negative symptoms.

    Science.gov (United States)

    Carpenter, W T; Breier, A; Buchanan, R W; Kirkpatrick, B; Shepard, P; Weiner, E

    2000-10-01

    Hypodopaminergic and hyponoradrenergic pathophysiology may be a basis for primary and/or secondary negative symptoms in schizophrenia. The hypothesis that enhanced neurotransmission in these systems would be therapeutic for negative symptoms was tested by comparing mazindol and placebo in a double-blind, cross-over design trial. Outcome following mazindol supplementation was comparable to placebo supplementation (F(1,30) = 0.9; p = .57). Results for deficit and non-deficit schizophrenia subjects were similar, and were not affected by whether concurrent the antipsychotic drug treatment was clozapine, fluphenazine, or haloperidol. The efficacy hypothesis was not supported for either primary or secondary negative symptoms.

  4. [APPLICATION OF NEGATIVE PRESSURE THERAPY].

    Science.gov (United States)

    Laginja, S; Marinović, M

    2016-01-01

    Negative pressure therapy is gradually taking an increasingly important role in the treatment of chronic wound healing because of its simple application in hospital or outpatient setting and good comfort with no pain for the patient. Chronic wound healing is accelerated in comparison with other conservative treatments. The level of negative pressure is between 40 and 125 mm Hg below ambient. Direct and indirect effect of the negative pressure therapy helps in wound healing and provides good preparation for definitive surgical management of wounds.

  5. Adjective metaphors evoke negative meanings.

    Directory of Open Access Journals (Sweden)

    Maki Sakamoto

    Full Text Available Previous metaphor studies have paid much attention to nominal metaphors and predicative metaphors, but little attention has been given to adjective metaphors. Although some studies have focused on adjective metaphors, they only examined differences in the acceptability of various types of adjective metaphors. This paper explores the cognitive effects evoked by adjective metaphors. Three psychological experiments revealed that (1 adjective metaphors, especially those modified by color adjectives, tend to evoke negative effect; (2 although the meanings of metaphors are basically affected by the meanings of their vehicles, when a vehicle has a neutral meaning, negative meanings are evoked most frequently for adjective metaphors compared to nominal and predicative metaphors; (3 negative meanings evoked by adjective metaphors are related to poeticness, and poetic metaphors evoke negative meanings more easily than less poetic metaphors. Our research sheds new light on studies of the use of metaphor, which is one of the most basic human cognitive abilities.

  6. Ferroelectric Negative Capacitance Domain Dynamics

    OpenAIRE

    Hoffmann, Michael; Khan, Asif Islam; Serrao, Claudy; Lu, Zhongyuan; Salahuddin, Sayeef; Pešić, Milan; Slesazeck, Stefan; Schroeder, Uwe; Mikolajick, Thomas

    2017-01-01

    Transient negative capacitance effects in epitaxial ferroelectric Pb(Zr$_{0.2}$Ti$_{0.8}$)O$_3$ capacitors are investigated with a focus on the dynamical switching behavior governed by domain nucleation and growth. Voltage pulses are applied to a series connection of the ferroelectric capacitor and a resistor to directly measure the ferroelectric negative capacitance during switching. A time-dependent Ginzburg-Landau approach is used to investigate the underlying domain dynamics. The transien...

  7. Negative magnetic relaxation in superconductors

    Directory of Open Access Journals (Sweden)

    Krasnoperov E.P.

    2013-01-01

    Full Text Available It was observed that the trapped magnetic moment of HTS tablets or annuli increases in time (negative relaxation if they are not completely magnetized by a pulsed magnetic field. It is shown, in the framework of the Bean critical-state model, that the radial temperature gradient appearing in tablets or annuli during a pulsed field magnetization can explain the negative magnetic relaxation in the superconductor.

  8. Use of Negation in Search

    Science.gov (United States)

    2010-06-01

    as of May 2010, produced a large number of images of Volkswagen Beetles as shown in Figure 8. After indicating they were ready to proceed... Volkswagen 1 beetle -VW -car 1 beetle –car - Volkswagen 1 beetle -VW - Volkswagen 1 beetle -VW -car - Volkswagen 1 black beetle Not within first 30...that had many Volkswagen Beetles in the results, why did you choose not to use negation?] 9. [Do you think that negation would have been useful in

  9. [Negative symptoms and cerebral imaging].

    Science.gov (United States)

    Kaladjian, A; Belzeaux, R; Adida, M; Azorin, J-M

    2015-12-01

    A number of neuroanatomical and neurofonctional abnormalities have been evidenced by cerebral imaging studies in patients suffering from schizophrenia. Nevertheless, those specifically associated with the negative symptoms of this disease are still insufficiently known. This work is a review of selected studies that have assessed the brain correlates of negative symptoms in schizophrenia. Approaches using structural imaging have highlighted reduction of gray matter density or cortical thickness associated with negative symptoms, which is rather sparsely distributed within the frontal and temporal regions, localized nevertheless more particularly in the frontal medial and orbitofrontal areas, as well as the amygdalo-hippocampic complex. These deficits are concurrent with a loss of integrity of the principal paths of white matter tracts between frontal and limbic regions. On the other hand, neurofonctional abnormalities associated with negative symptoms involve especially the frontal areas and limbic striatum. A disturbed functioning within the fronto-striatal loops, related to a striatal dopaminergic deficit, may represent a potential explanatory hypothesis of the negative symptoms of schizophrenia, as suggested by studies using Positron Emission Tomography on this topic or neuroimaging studies on the effects of antipsychotics. A better identification of the cerebral abnormalities associated with the negative dimension of schizophrenia, with regard to the lateralization of these abnormalities or to their changes during the course of the disease, could offer new therapeutic modalities for the treatment of this dimension which, until now, remains few responsive to conventional pharmacological treatments. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. SM-1 negative ion source

    International Nuclear Information System (INIS)

    Huang Zhenjun; Wang Jianzhen

    1987-01-01

    The working principle and characteristics of SM-1 Negative Ion Source is mainly introduced. In the instrument, there is a device to remove O 3 . This instrument can keep high density of negative ions which is generated by the electrical coronas setting out electricity at negative high voltage and can remove the O 3 component which is harmful to the human body. The density of negative ions is higher than 2.5 x 10 6 p./cm 3 while that of O 3 components is less than 1 ppb at the distance of 50 cm from the panel of the instrument. The instrument sprays negative ions automatically without the help of electric fan, so it works noiselessly. It is widely used in national defence, industry, agriculture, forestry, stock raising, sidelines and in the places with an equipment of low density of negative ion or high concentration of O 3 components. Besides, the instrument may also be used to treat diseases, to prevent against rot, to arrest bacteria, to purify air and so on

  11. Evidence-based Diagnostics: Adult Septic Arthritis

    Science.gov (United States)

    Carpenter, Christopher R.; Schuur, Jeremiah D.; Everett, Worth W.; Pines, Jesse M.

    2011-01-01

    % (95% confidence interval [CI] = 17% to 38%). With the exception of joint surgery (positive likelihood ratio [+LR] = 6.9) or skin infection overlying a prosthetic joint (+LR = 15.0), history, physical examination, and serum tests do not significantly alter posttest probability. Serum inflammatory markers such as white blood cell (WBC) counts, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) are not useful acutely. The interval LR for synovial white blood cell (sWBC) counts of 0 × 109–25 × 109/ L was 0.33; for 25 × 109–50 × 109/L, 1.06; for 50 × 109–100 × 109/L, 3.59; and exceeding 100 × 109/L, infinity. Synovial lactate may be useful to rule in or rule out the diagnosis of septic arthritis with a +LR ranging from 2.4 to infinity, and negative likelihood ratio (−LR) ranging from 0 to 0.46. Rapid polymerase chain reaction (PCR) of synovial fluid may identify the causative organism within 3 hours. Based on 56% sensitivity and 90% specificity for sWBC counts of >50 × 109/L in conjunction with best-evidence estimates for diagnosis-related risk and treatment-related risk/benefit, the arthrocentesis test threshold is 5%, with a treatment threshold of 39%. Conclusions Recent joint surgery or cellulitis overlying a prosthetic hip or knee were the only findings on history or physical examination that significantly alter the probability of nongonococcal septic arthritis. Extreme values of sWBC (>50 × 109/L) can increase, but not decrease, the probability of septic arthritis. Future ED-based diagnostic trials are needed to evaluate the role of clinical gestalt and the efficacy of nontraditional synovial markers such as lactate. PMID:21843213

  12. Technical diagnostics of steam turbines

    International Nuclear Information System (INIS)

    Vlckova, B.; Drahy, J.

    1987-01-01

    This paper deals with practical experience in application of technical diagnostics methods to steam turbines, in particular using pedestal and shaft vibration measurements as well as estimation of bearing metal temperature and ultrasound emission signals. An estimation of effectiveness of the diagnostics methods used is given on the basis of experimental investigations made on a 30-MW turbine. (author)

  13. Imaging diagnostics of the foot

    International Nuclear Information System (INIS)

    Szeimies, Ulrike; Staebler, Axel; Walther, Markus

    2012-01-01

    The book on imaging diagnostics of the foot contains the following chapters: (1) Imaging techniques. (2) Clinical diagnostics. (3) Ankle joint and hind foot. (4) Metatarsus. (5) Forefoot. (6) Pathology of plantar soft tissue. (7) Nervous system diseases. (8) Diseases without specific anatomic localization. (9) System diseases including the foot. (10) Tumor like lesions. (11) Normative variants.

  14. Dual Processing and Diagnostic Errors

    Science.gov (United States)

    Norman, Geoff

    2009-01-01

    In this paper, I review evidence from two theories in psychology relevant to diagnosis and diagnostic errors. "Dual Process" theories of thinking, frequently mentioned with respect to diagnostic error, propose that categorization decisions can be made with either a fast, unconscious, contextual process called System 1 or a slow, analytical,…

  15. Psychometric perspectives on diagnostic systems

    NARCIS (Netherlands)

    Borsboom, D.

    2008-01-01

    The author identifies four conceptualizations of the relation between symptoms and disorders as utilized in diagnostic systems such as the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV; American Psychiatric Association, 1994): A constructivist perspective, which holds

  16. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  17. Moyamoya disease: Diagnostic imaging

    International Nuclear Information System (INIS)

    Tarasów, Eugeniusz; Kułakowska, Alina; Łukasiewicz, Adam; Kapica-Topczewska, Katarzyna; Korneluk-Sadzyńska, Alicja; Brzozowska, Joanna; Drozdowski, Wiesław

    2011-01-01

    Moyamoya disease is a progressive vasculopathy leading to stenosis of the main intracranial arteries. The incidence of moyamoya disease is high in Asian countries; in Europe and North America, the prevalence of the disease is considerably lower. Clinically, the disease may be of ischaemic, haemorrhagic and epileptic type. Cognitive dysfunction and behavioral disturbance are atypical symptoms of moyamoya disease. Characteristic angiographic features of the disease include stenosis or occlusion of the arteries of the circle of Willis, as well as the development of collateral vasculature. Currently, magnetic resonance angiography and CT angiography with multi-row systems are the main imaging methods of diagnostics of the entire range of vascular changes in moyamoya disease. The most common surgical treatment combines the direct arterial anastomosis between the superficial temporal artery and middle cerebral, and the indirect synangiosis involving placement of vascularised tissue in the brain cortex, in order to promote neoangiogenesis. Due to progressive changes, correct and early diagnosis is of basic significance in selecting patients for surgery, which is the only effective treatment of the disease. An appropriate qualification to surgery should be based on a comprehensive angiographic and imaging evaluation of brain structures. Despite the rare occurrence of moyamoya disease in European population, it should be considered as one of causes of ischaemic or haemorrhagic strokes, especially in young patients

  18. Intelligent diagnostics systems

    Science.gov (United States)

    Mcquiston, Barbara M.; Dehoff, Ronald L.

    1992-01-01

    Intelligent systems have been applied to today's problems and could also be applied to space operations integrity. One of these systems is the XMAN tool designed for 'troubleshooting' jet engines. XMAN is the eXpert MAiNtenance tool developed to be an expert information analysis tool which stores trending and diagnostic data on Air Force engines. XMAN operates with a 'network topology' which follows a flow chart containing engine management information reports required by the governments technical order procedures. With XMAN technology, the user is able to identify engine problems by presenting the assertions of the fault isolation logic and attempting to satisfy individual assertions by referring to the databases created by an engine monitoring system. The troubleshooting process requires interaction between the technician and the computer to acquire new evidence form auxiliary maintenance tests corroboration of analytical results to accurately diagnose equipment malfunctions. This same technology will be required for systems which are functioning in space either with an onboard crew, or with an unmanned system. The technology and lessons learned developing this technology while suggesting definite applications for its use with developing space systems are addressed.

  19. Laboratory diagnostics of malaria

    Science.gov (United States)

    Siahaan, L.

    2018-03-01

    Even now, malaria treatment should only be administered after laboratory confirmation. There are several principal methods for diagnosing malaria. All these methods have their disadvantages.Presumptive treatment of malaria is widely practiced where laboratory tests are not readily available. Microscopy of Giemsa-stained thick and thin blood films remains the gold standard for the diagnosis of malaria infection. The technique of slide preparation, staining and reading are well known and standardized, and so is the estimate of the parasite density and parasite stages. Microscopy is not always available or feasible at primary health services in limited resource settings due to cost, lack of skilled manpower, accessories and reagents required. Rapid diagnostic tests (RDTs) are potential tools for parasite-based diagnosis since the tests are accurate in detecting malaria infections and are easy to use. The test is based on the capture of parasite antigen that released from parasitized red blood cells using monoclonal antibodies prepared against malaria antigen target. Polymerase Chain Reaction (PCR), depend on DNA amplification approaches and have higher sensitivity than microscopy. PCR it is not widely used due to the lack of a standardized methodology, high costs, and the need for highly-trained staff.

  20. Chorioamnionitis: a diagnostic approach

    Directory of Open Access Journals (Sweden)

    Yeni Arroyave

    2013-09-01

    Full Text Available Introduction: Chorioamnionitis has been defined as inflammation of the amnion and chorion membranes in response to microbial invasion or other pathological process. May be clinical when clinical manifestations of local and systemic inflammation is present, subclinical when no clinical signs; histological if there is microscopic evidence of infection or inflammation in placental examination. The frequency of chorioamnionitis is highly variable, depending on the risk factors of the population studied, the criteria used for diagnosis (clinical or histological and gestational age. This clinical entity is important because results in maternal, fetal and neonatal aftermath such as postpartum endometritis, pelvic abscess and high risk of caesarean section in the mother. In the fetus, Prematurity, perinatal death, pneumonia, sepsis, intraventricular hemorrhage and cerebral palsy. Make an early and accurate diagnosis is essential to prevent these aftermath. Objective: Carry out a literature review on the diagnosis of chorioamnionitis. Methods: A search of the literature published during the last 5 years in Pubmed, Tripdatabase, Science direct and Embase biomedical was made, selecting the most relevant literature on chorioamnionitis. Conclusions: Despite medical advances in diagnostic methods, unify parameters for early diagnosis of chorioamnionitis is still a challenge, as shown by the variability of the evidence found in this review.

  1. Diagnostic evaluation of rhabdomyolysis.

    Science.gov (United States)

    Nance, Jessica R; Mammen, Andrew L

    2015-06-01

    Rhabdomyolysis is characterized by severe acute muscle injury resulting in muscle pain, weakness, and/or swelling with release of myofiber contents into the bloodstream. Symptoms develop over hours to days after an inciting factor and may be associated with dark pigmentation of the urine. Serum creatine kinase and urine myoglobin levels are markedly elevated. Clinical examination, history, laboratory studies, muscle biopsy, and genetic testing are useful tools for diagnosis of rhabdomyolysis, and they can help differentiate acquired from inherited causes of rhabdomyolysis. Acquired causes include substance abuse, medication or toxic exposures, electrolyte abnormalities, endocrine disturbances, and autoimmune myopathies. Inherited predisposition to rhabdomyolysis can occur with disorders of glycogen metabolism, fatty acid β-oxidation, and mitochondrial oxidative phosphorylation. Less common inherited causes of rhabdomyolysis include structural myopathies, channelopathies, and sickle-cell disease. This review focuses on the differentiation of acquired and inherited causes of rhabdomyolysis and proposes a practical diagnostic algorithm. Muscle Nerve 51: 793-810, 2015. © 2015 Wiley Periodicals, Inc.

  2. Bayesian modelling of fusion diagnostics

    Science.gov (United States)

    Fischer, R.; Dinklage, A.; Pasch, E.

    2003-07-01

    Integrated data analysis of fusion diagnostics is the combination of different, heterogeneous diagnostics in order to improve physics knowledge and reduce the uncertainties of results. One example is the validation of profiles of plasma quantities. Integration of different diagnostics requires systematic and formalized error analysis for all uncertainties involved. The Bayesian probability theory (BPT) allows a systematic combination of all information entering the measurement descriptive model that considers all uncertainties of the measured data, calibration measurements, physical model parameters and measurement nuisance parameters. A sensitivity analysis of model parameters allows crucial uncertainties to be found, which has an impact on both diagnostic improvement and design. The systematic statistical modelling within the BPT is used for reconstructing electron density and electron temperature profiles from Thomson scattering data from the Wendelstein 7-AS stellarator. The inclusion of different diagnostics and first-principle information is discussed in terms of improvements.

  3. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Peterson, B.J.

    2003-01-01

    Standard diagnostics for fundamental plasma parameters and for plasma physics are routinely utilized for daily operation and physics study in the large helical device (LHD) with high reliability. Diagnostics for steady state plasma are intensively developed, especially for T e , n e (YAG laser Thomson, CO 2 laser polarimeter), data acquisition in steady state, heat resistant probes. To clarify the plasma property of the helical structure, 2-D or 3-D diagnostics are intensively developed: Tangential cameras (Fast SX TV, Photon counting CCD, H α TV); Tomography (Tangential SX CCD, Bolometer); Imaging (Bolometer, ECE, Reflectometer). Divertor and edge physics are one of important key issues for steady state operation. Diagnostics for neutral flux (H α array, Zeeman spectroscopy) and n e (Fast scanning probe, Li beam probe, Pulsed radar reflectometer). In addition to these, advanced diagnostics are being intensively developed with national and international collaborations in LHD. (author)

  4. SPIDER beam dump as diagnostic of the particle beam

    Energy Technology Data Exchange (ETDEWEB)

    Zaupa, M., E-mail: matteo.zaupa@igi.cnr.it; Sartori, E. [Università degli Studi di Padova, Via 8 Febbraio 2, Padova 35122 (Italy); Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy); Dalla Palma, M.; Brombin, M.; Pasqualotto, R. [Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy)

    2016-11-15

    The beam power produced by the negative ion source for the production of ion of deuterium extracted from RF plasma is mainly absorbed by the beam dump component which has been designed also for measuring the temperatures on the dumping panels for beam diagnostics. A finite element code has been developed to characterize, by thermo-hydraulic analysis, the sensitivity of the beam dump to the different beam parameters. The results prove the capability of diagnosing the beam divergence and the horizontal misalignment, while the entity of the halo fraction appears hardly detectable without considering the other foreseen diagnostics like tomography and beam emission spectroscopy.

  5. Teaching diagnostic approach to a patient through cinema.

    Science.gov (United States)

    Kalra, Gurvinder

    2011-11-01

    Films are produced with the aim of entertaining people, but recently there has been increasing use of films to educate medical trainees about various disorders, symptoms of these disorders, patient-therapist interactions, and various other medical and psychiatric issues. Discussions in academic circles have moved from criticism of negative portrayals of mental illness in earlier films to their use in teaching sessions. Films can be used either in full length or clip format to conduct training modules. Use of the film Stigmata to train residents about diagnostic dilemmas and taking a diagnostic approach to patients is discussed. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Gram-negative and Gram-positive bacterial extracellular vesicles.

    Science.gov (United States)

    Kim, Ji Hyun; Lee, Jaewook; Park, Jaesung; Gho, Yong Song

    2015-04-01

    Like mammalian cells, Gram-negative and Gram-positive bacteria release nano-sized membrane vesicles into the extracellular environment either in a constitutive manner or in a regulated manner. These bacterial extracellular vesicles are spherical bilayered proteolipids enriched with bioactive proteins, lipids, nucleic acids, and virulence factors. Recent progress in this field supports the critical pathophysiological functions of these vesicles in both bacteria-bacteria and bacteria-host interactions. This review provides an overview of the current understanding on Gram-negative and Gram-positive bacterial extracellular vesicles, especially regarding the biogenesis, components, and functions in poly-species communities. We hope that this review will stimulate additional research in this emerging field of bacterial extracellular vesicles and contribute to the development of extracellular vesicle-based diagnostic tools and effective vaccines against pathogenic Gram-negative and Gram-positive bacteria. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  8. Charged particle radioisotope production at Instituto de Engenharia Nuclear - IEN

    International Nuclear Information System (INIS)

    Lemos Junior, O.F.

    1992-05-01

    A variable energy isochronous cyclotron (CV-28) was installed in 1974 at the Instituto de Engenharia Nuclear in Rio de Janeiro, with the purpose, among others, of irradiating suitable targets to produce radioisotopes for medical diagnostic studies. This papers is an overview of the work done in the last two decades and reports the present status on the production of iodine-123 and gallium-67. (author)

  9. A comparison between dopamine transporters imaging and perfusion SPECT with HMPAO-99mTc in the diagnosis of dementia with Lewy bodies

    International Nuclear Information System (INIS)

    Voitota, J.B.; Emptaz, A.; Szurhaj, W.; Steinling, M.; Bombois, St.; Pasquier, F.

    2007-01-01

    Scintigraphic imaging of dementia relies today essentially on the study of brain single photo emission computed tomography (SPECT) perfusion, after intravenous injection of 99m Tc radiopharmaceutical. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear medicine (http:// eanm.org). Dementia with Lewy bodies is the second cause of degenerative dementia. Differential diagnosis may be difficult, in spite of the emergence of standardized diagnostic criteria. Tomo-scintigraphy using iodine 123-labelled FP-CIT (DaTSCAN) could play a role in this process. Cerebral perfusion SPECT imaging is an important step of demented patient evaluation. We compared the diagnostic performance of both of these procedures in the diagnosis of dementia with Lewy bodies. We studied 15 patients; ten DaTSCAN and 14 cerebral perfusion studies were performed. Clinical diagnosis at the end of follow-up was established as the diagnostic reference. Cerebral perfusion SPECT showed a very low sensitivity (20%) and a good specificity (89%); considering a prevalence of dementia with Lewy bodies of 20%, positive predictive value (PPV) was 31% and negative predictive value (NPV) 82%. Performances of DaTSCAN tomo-scintigraphy were more encouraging, (sensitivity and specificity of 100%); predictive values are both of 100%. As a conclusion, DaTSCAN tomo-scintigraphy performs better than cerebral perfusion SPECT in the diagnosis of dementia with Lewy bodies and no conjoint or sequential use of those tests can be recommended. (authors)

  10. [Nuclear morphology in false negative and negative rectal biopsies (author's transl)].

    Science.gov (United States)

    Rilke, F; Clemente, C; Pilotti, S

    1975-01-01

    An typical nuclear structure consisting of a cribriform and condensed chromatin pattern with hyperchromasia, a small nucleolus and a moderately increased nuclear-cytoplasmic ratio was observed in the epithelial cells of the crypts and in the stromal and muscular cells of 51 out of 70 oncologically negative biopsies of the rectal mucosa. The subsequent retrieval of all clinical and histologia data revealed that the 51 cases included 39 of adenocarcinoma of the large intestine either present (15 cases) at a variable distance from the false negative biopsy or removed previously (24 cases), 7 of extra-intestinal malignant tumor (parotid gland, urinary bladder, endometrium, breast, stomach, metastatic, anus) and 5 with benign conditions of the large intestine. Of the remaining 19 cases whose biopsies did not reveal the atypical nuclear structure 16 had benign lesions of the large intestine and nowhere evidence of malignancy, two had an adenocarcinoma of the large bowel (one present and one removed previously) and one a carcinoma of the anus. In the rectal biopsies examined the atypical nuclear structure was detected in 93.9% of the cases with a malignant tumor either present or removed previously and in 19% of the cases with benign conditions. The morphologic evidence indicated that the atypical nuclear structure was compatible with a possible distrubance of the mitotic cycle since the findings were restricted to the generative compartment of rectal epithelium. The results are discussed in connection with their possible practical use as a diagnostic aid in the evaluation and interpretation of false negative and negative rectal biopsies as well as with their possible significance in the biology of tumor-bearing hosts.

  11. DIAGNOSTIC KARATE TESTS

    Directory of Open Access Journals (Sweden)

    Dragan Doder

    2006-06-01

    Full Text Available The basic condition of a successful process of karate training is making diagnosis of any sportsman. Assessment is usually done by a coach and it is a part of technical process; quantity measurements are also a part of the evaluation which contains these tests. The suggested diagnostic karate tests are based on the knowledge of the specific karate characteristics and on the research which was done so far (Zulić 1985, Milošević and Zulić 1988, Jovanović 1981, 1988, Mudrić 1994, Doder 1998, 2000, 2005, Babiak, Doder, Savić, Golik2001, Savić, Doder, Babiak 2002. Karate as a type of sport demands diagnosis of many relevant characteristics, abilities and features that are thought to be predominant in the analysis of this kind of sport. Knowing all relevant anthropologic karate dimensions it is possible to select necessary instruments for measuring and to test those dimensions that karate results depend on. Considering all scientific knowledge and achievements in this field the fallowing tests are suggested: Morphologic measures: body height, arm span, arm length, pelvis width, hand ankle diameter, knees diameter, elbow diameter, body weight, parameters of one’s chest, stomach, the upper and lower part of one’s arm and legs, then to examine the skin fold of any sportsman’s arms, back, stomach and legs. Functional diagnosis: measuring of the maximum amount of oxygen breathed in. Mobility tests: the speed of simple movements, the speed of karate technique, deep bow on the bench, shoulders capability of moving, the static strength of hands, legs, shoulders and middle part of a body, jump height, an average jump, and the percentage of maximum achievement in jumping.

  12. Negative symptoms of schizophrenia: A historical, contemporary, and futuristic view

    Directory of Open Access Journals (Sweden)

    Shae-Leigh Cynthia Vella

    2015-01-01

    Full Text Available This paper explores the evolution of the conceptualization of schizophrenia. Specifically, the paper focuses upon negative symptomology and the emphasis that such symptoms have garnered over time. Negative symptoms are associated with higher levels of impairment and poorer outcomes in schizophrenia. Historically, negative symptoms were the core feature of schizophrenia in the early conceptualizations of Kraepelin and Bleuler, holding precedence until the emergence of Schneiderian theory in the 1970′s. The focus on negative symptoms then changed to positive symptoms; which is still the key focus today. This shift in emphasis has resulted in a dearth of knowledge and treatment for such symptoms and as such an area requiring further research. The paper also addresses the conceptual changes in the nosology of Schizophrenia and other psychosis with respect to the Diagnostic and Statistical Manual of Mental Disorders-5. Further the potential for the clinical assessment interview for negative symptoms to facilitate understanding and treatments for negative symptomology in schizophrenia is also discussed.

  13. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P. E.; Sanchez, J.

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  14. Plasma diagnostics for tokamaks and stellarators

    International Nuclear Information System (INIS)

    Stott, P.E.; Sanchez, J.

    1994-01-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Sattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma

  15. Ares I-X Ground Diagnostic Prototype

    Science.gov (United States)

    Schwabacher, Mark; Martin, Rodney; Waterman, Robert; Oostdyk, Rebecca; Ossenfort, John; Matthews, Bryan

    2010-01-01

    Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype

  16. Incisional Negative Pressure Wound Therapy

    DEFF Research Database (Denmark)

    Hyldig, Nana; Birke-Sorensen, Hanne; Kruse, Marie

    Aim: Postoperative wound complications make many surgical procedures unnecessarily complex, particularly in high-risk patients. Negative Pressure Wound Therapy is well recognized in the management of open wounds. In recent years, it has been introduced as well in the management of closed surgical...... incisions to reduce postoperative wound complications, though the evidence base to support this intervention is limited. The aim of this study was to assess if Negative Pressure Wound Therapy (NPWT) reduces postoperative complications when applied on closed surgical incisions. Method: A systematic review...

  17. Negative Attitudes, Networks and Education

    DEFF Research Database (Denmark)

    Bennett, Patrick; la Cour, Lisbeth; Larsen, Birthe

    This paper theoretically and empirically assesses the potential explanations behind the educational gap between young natives and immigrants using two measures, negative attitudes towards immigrants and networking. The paper considers that two these parameters may influence high and uneducated...... workers as well as immigrants and natives differently, creating different incentives to acquire education for the two groups. Using rich Danish administrative data, this paper finds suggestive evidence rejecting the theoretical case where negative attitudes decrease 1st generation immigrant education...... and indications that quality of networks seems to matter more for immigrants than the quantity of individuals in a potential network....

  18. [DIAGNOSTIC ERRORS IN INTERNAL MEDICINE].

    Science.gov (United States)

    Schattner, Ami

    2017-02-01

    Diagnostic errors remain an important target in improving the quality of care and achieving better health outcomes. With a relatively steady rate estimated at 10-15% in many settings, research aiming to elucidate mechanisms of error is highly important. Results indicate that not only cognitive mistakes but a number of factors acting together often culminate in a diagnostic error. Far from being 'unpreventable', several methods and techniques are suggested that may show promise in minimizing diagnostic errors. These measures should be further investigated and incorporated into all phases of medical education.

  19. Mammary carcinoma diagnostics and therapy

    International Nuclear Information System (INIS)

    Fischer, Uwe; Baum, Friedemann

    2014-01-01

    The book on mammary carcinoma diagnostics and therapy covers the following issues: development, anatomy and physiology of the mammary glands, pathology of benign and malign mammary gland changes, non-imaging diagnostics; mammography; ultrasonic mammography; magnetic resonance tomography of the mammary glands; imaging diagnostics findings; mammary interventions; examination concepts; operative therapy of the mammary carcinoma; chemotherapy of the mammary carcinoma; radio-oncological therapy of the mammary carcinoma; logistics in a medical center for mammary gland diseases; logistics in an interdisciplinary center for mammary diseases; dialogue conduction and psycho-social attendance.

  20. THE CURRENT METHODS FOR MOLECULAR DIAGNOSTICS OF FISH DISEASES (REVIEW

    Directory of Open Access Journals (Sweden)

    O. Zaloilo

    2016-06-01

    Full Text Available Purpose. The methods of molecular diagnostic (MMD gradually become widespread in modern fish farming. MMD contain a wide variety of specific approaches, each of which has distinct limits of their possible applications and is characterized by individual peculiarities in practical performance. In addition to high sensitivity and the possibility of rapid diagnostics, the main advantage of molecular methods is to determine the uncultivated infectious agents. DNA amplification allows identifying pathogenic microorganisms at very small quantities even in the minimum sample volume. Molecular methods of diagnostic enable the determination of infection in latent or acute phases. These methods allow showing the differences between pathogens with similar antigenic structures. The current literature data on this subject usually show a methodology in the narrow context of the tasks or practical results obtained through such approaches. Thus, a synthesis of existing information on the mechanisms of action and the limits of the typical problems of basic methods of molecular diagnostics are an urgent task of fish breeding. In particular, the following description will more effectively choose one or several approaches to identify pathogens in fish. Findings. This paper reviews the basic molecular methods that are used in the world's aquaculture for diagnosis of various diseases in commercial fish species. Originality. This work is a generalization of data on the principles and mechanisms for the implementation of diagnostics based on modern molecular techniques. For each of the mentioned approaches, the most promising areas of application were shown. The information is provided in the form of a comparative analysis of each methodology, indicating positive and negative practical aspects. Practical value. The current review of modern methods of molecular diagnostic in aquaculture is focused on practical application. Generalizing and analytical information can be

  1. Production of negative helium ions

    International Nuclear Information System (INIS)

    Toledo, A.S. de; Sala, O.

    1977-01-01

    A negative helium ion source using potassium charge exchange vapor has been developed to be used as an injector for the Pelletron accelerator. 3 He and α beam currents of up to 2μA have been extracted with 75% particle transmission through the machine [pt

  2. Diagnostics for the National Compact Stellarator Experiment

    International Nuclear Information System (INIS)

    Stratton, B.C.; Johnson, D.; Feder, R.; Fredrickson, E.; Neilson, H.; Takahashi, H.; Zarnstorf, M.; Cole, M.; Goranson, P.; Lazarus, E.; Nelson, B.

    2003-01-01

    The status of planning of the National Compact Stellarator Experiment (NCSX) diagnostics is presented, with the emphasis on resolution of diagnostics access issues and on diagnostics required for the early phases of operation

  3. Unimode metamaterials exhibiting negative linear compressibility and negative thermal expansion

    International Nuclear Information System (INIS)

    Dudek, Krzysztof K; Attard, Daphne; Caruana-Gauci, Roberto; Grima, Joseph N; Wojciechowski, Krzysztof W

    2016-01-01

    Unimode metamaterials made from rotating rigid triangles are analysed mathematically for their mechanical and thermal expansion properties. It is shown that these unimode systems exhibit positive Poisson’s ratios irrespective of size, shape and angle of aperture, with the Poisson’s ratio exhibiting giant values for certain conformations. When the Poisson’s ratio in one loading direction is larger than +1, the systems were found to exhibit the anomalous property of negative linear compressibility along this direction, that is, the systems expand in this direction when hydrostatically compressed. Also discussed are the thermal expansion properties of these systems under the assumption that the units exhibit increased rotational agitation once subjected to an increase in temperature. The effect of the geometric parameters on the aforementioned thermo-mechanical properties of the system, are discussed, with the aim of identifying negative behaviour. (paper)

  4. Thioaptamer Diagnostic System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) in partnership with Sandia National Laboratories will develop a Thioaptamer Diagnostic System (TDS) in response to Topic X10.01 Reusable...

  5. Cyclotron radiation as Tokamak diagnostics

    International Nuclear Information System (INIS)

    Fiedler-Ferrari, N.

    1985-01-01

    A brief introduction to the use of Electron Cyclotron Emission as diagnostics in tokamaks is made. The utilization feasibility of this dignostics in the TBR-1 and TTF2A tokamaks is discussed. (L.C.) [pt

  6. Diagnostics and Instrumentation for FEL

    CERN Document Server

    Couprie, M E

    2001-01-01

    Free Electron Laser are coherent sources of radiation based on the interaction of a relativistic electron beam in an undulator field. According to the energy of the accelerator, they presently cover a wide spectral range, from the infra-red to the VUV. FELs combine the diagnostics of typical laser systems (for the measurement of spectral and temporal characteristics, the transverse mode pattern, the polarisation) and the diagnostics of relativistic electron beams. The electron beam is characterised in order to evaluate and control the FEL performances, but also in order to measure the effect of the FEL on the electron beam. The FEL characteristics are monitored with various types of detectors, depending mainly on the spectral range. Diagnostics for Linac based Infra Red FELs and storage ring FELs in the UV-VUV will be described. Particular instrumentation, required for FEL operation, such as the optical resonator, possible diagnostics inside the undulator will also be analysed.

  7. Microfluidic technology for molecular diagnostics.

    Science.gov (United States)

    Robinson, Tom; Dittrich, Petra S

    2013-01-01

    Molecular diagnostics have helped to improve the lives of millions of patients worldwide by allowing clinicians to diagnose patients earlier as well as providing better ongoing therapies. Point-of-care (POC) testing can bring these laboratory-based techniques to the patient in a home setting or to remote settings in the developing world. However, despite substantial progress in the field, there still remain many challenges. Progress in molecular diagnostics has benefitted greatly from microfluidic technology. This chapter aims to summarise the more recent advances in microfluidic-based molecular diagnostics. Sections include an introduction to microfluidic technology, the challenges of molecular diagnostics, how microfluidic advances are working to solve these issues, some alternative design approaches, and detection within these systems.

  8. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S; Ozaki, T; Ashikawa, N; Emoto, M; Goto, M; Hamada, Y; Ida, K; Ido, T; Iguchi, H; Inagaki, S; Isobe, M; Kawahata, K; Khlopenkov, K; Kobuchi, T; Liang, Y; Masuzaki, S; Minami, T; Morita, S; Muto, S; Nagayama, Y; Nakanishi, H; Narihara, K; Nishizawa, A; Ohdachi, S; Osakabe, M; Peterson, B J; Sakakibara, S; Sasao, M; Sato, K; Shoji, M; Tamura, N; Tanaka, K; Toi, K; Tokuzawa, T; Watanabe, K; Watanabe, T; Yamada, I; Goncharov, P; Ejiri, A; Okajima, S; Mase, A; Tsuji-Iio, S; Akiyama, T; Lyon, J F; Vyacheslavov, L N; Sanin, A

    2003-01-01

    The recent diagnostic developments on the large helical device (LHD) are described briefly. LHD is the largest helical machine with all superconducting coils, and its purpose is to prove the ability of a helical system to confine a fusion-relevant plasma in steady state. According to the missions of LHD research, the diagnostic devices are categorized as follows: diagnostics for (i) high nτ E T plasmas and transport physics; (ii) magnetohydrodynamic stability; (iii) long pulse operation and divertor function; and (iv) energetic particles. These are briefly described focusing on the recent developments of the devices. Since the LHD experiment started in March 1998, five series of experimental campaigns have been carried out. The LHD diagnostics during these periods were operated successfully, and contributed to the analysis of the experimental results

  9. Recent diagnostic developments on LHD

    Energy Technology Data Exchange (ETDEWEB)

    Sudo, S; Ozaki, T; Ashikawa, N; Emoto, M; Goto, M; Hamada, Y; Ida, K; Ido, T; Iguchi, H; Inagaki S; Isobe, M; Kawahata, K; Khlopenkov, K; Kobuchi, T; Liang, Y; Masuzaki, S; Minami, T; Morita, S; Muto, S; Nagayama, Y; Nakanishi, H; Narihara, K; Nishizawa, A; Ohdachi, S; Osakabe, M; Peterson, BJ; Sakakibara, S; Sasao, M; Sato, K; Shoji, M; Tamura, N; Tanaka, K; Toi, K; Tokuzawa, T; Watanabe, K; Watanabe, T; Yamada, I [National Institute for Fusion Science, Toki 509-5292 (Japan); Goncharov, P [Grad. Univ. Advanced Studies, Oroshi-cho 322-6, Toki 509-5292 (Japan); Ejiri, A [University of Tokyo, Tokyo 113-0033 (Japan); Okajima, S [Chubu University, Kasugai-shi, 487-8501 (Japan); Mase, A [Kyushu University, Kasuga, 816-8580 (Japan); Tsuji-Iio, S [Tokyo Institute of Technology, Meguro-ku, Tokyo 152-8550 (Japan); Akiyama, T [Tokyo Institute of Technology, Meguro-ku, Tokyo 152-8550 (Japan); Lyon, J F [Oak Ridge National Laboratory, Oak Ridge, TN 37831-8072 (United States); Vyacheslavov, L N [Budker Institute of Nuclear Physics, 630090, Novosibirsk (Russian Federation); Sanin, A [Budker Institute of Nuclear Physics, 630090, Novosibirsk (Russian Federation)

    2003-07-01

    The recent diagnostic developments on the large helical device (LHD) are described briefly. LHD is the largest helical machine with all superconducting coils, and its purpose is to prove the ability of a helical system to confine a fusion-relevant plasma in steady state. According to the missions of LHD research, the diagnostic devices are categorized as follows: diagnostics for (i) high n{tau}{sub E}T plasmas and transport physics; (ii) magnetohydrodynamic stability; (iii) long pulse operation and divertor function; and (iv) energetic particles. These are briefly described focusing on the recent developments of the devices. Since the LHD experiment started in March 1998, five series of experimental campaigns have been carried out. The LHD diagnostics during these periods were operated successfully, and contributed to the analysis of the experimental results.

  10. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  11. Laser Diagnostics for Spacecraft Propulsion

    Science.gov (United States)

    MacDonald-Tenenbaum, Natalia

    2015-09-01

    Over the past several decades, a variety of laser diagnostic techniques have been developed and applied to diagnose spacecraft propulsion devices. Laser diagnostics are inherently non-intrusive, and provide the opportunity to probe properties such as temperature, concentration or number density of plume species, and plume velocities in the harsh environments of combustion and plasma discharges. This presentation provides an overview of laser diagnostic capabilities for spacecraft propulsion devices such as small monopropellant thrusters, arcjets, ion engines and Hall thrusters. Particular emphasis is placed on recent developments for time-resolved ion velocity measurements in Hall thruster plumes. Results are presented for one such diagnostic method, a time-synchronized CW-laser induced fluorescence (LIF) technique based on a sample hold scheme. This method is capable of correlating measured fluorescence excitation lineshapes with high frequency current fluctuations in the plasma discharge of a Hall thruster and is tolerant of natural drifting in the current oscillation frequency.

  12. Diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B: a meta-analysis of diagnostic test.

    Science.gov (United States)

    Yin, Zhi; Zou, Jin; Li, Qiongxuan; Chen, Lizhang

    2017-04-04

    This study is aimed at evaluating the diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B through a meta-analysis of diagnostic test. We conducted a comprehensive search in the Pubmed, Embase, Web of Science, and Chinese National Knowledge Infrastructure before October 31, 2016. Stata 14.0 software was used for calculation and statistical analyses. We used the sensitivity, specificity, positive and negative likelihood ratio (PLR, NLR), diagnostic odds ratio (DOR) and 95% confidence intervals (CIs) to evaluate the diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B. Twenty-six studies were included in the final analyses, with a total of 8274 individuals. The pooled parameters are calculated from all studies: sensitivity of 0.69 (95%CI:0.63-0.75), specificity of 0.81 (95%CI: 0.73-0.87), PLR of 3.63 (95%CI:2.66-4.94), NLR of 0.38 (95%CI:0.32-0.44), DOR of 9.57 (95%CI: 6.67-13.74), and area under the curve (AUC) of 0.80 (95%CI: 0.76-0.83). We also conducted subgroup based on the range of cut-off values. Results from subgroup analysis showed that cut-off was the source of heterogeneity in the present study. The sensitivity and specificity of cut-off>2 were 0.69 and 0.95 with the AUC of 0.90 (95%CI: 0.87-0.92). The overall diagnostic value of FIB-4 is not very high for liver fibrosis in patients with hepatitis B. However, the diagnostic value is affected by the cut-off value. FIB-4 has relatively high diagnostic value for detecting liver fibrosis in patients with hepatitis B when the diagnostic threshold value is more than 2.0.

  13. Comment on α-particle diagnostics

    International Nuclear Information System (INIS)

    Sasao, M.

    1982-01-01

    The problems of the alpha-particle diagnostics using neutral atom doping beam were investigated. It might be sufficient to use the beam with the velocity of 0.8 v(α) in order to measure a wide range of the alpha particle velocity spectra. The required beam intensity may be 10 mA, if the neutral He fraction is large enough. The cross sections of neutralization with large neutral He fraction in various gases must be measured. The precise calculation of beam dynamics must be investigated. The test experiment in D-D plasma may be possible and useful. At present, in Japan, the negative ion sources of He are under development. The measurement of the cross sections is in progress. (Kato, T.)

  14. Diagnostic accuracy of spirometry in primary care

    Directory of Open Access Journals (Sweden)

    Dinant Geert-Jan

    2009-07-01

    Full Text Available Abstract Background To evaluate the sensitivity, specificity and predictive values of spirometry for the diagnosis of chronic obstructive pulmonary disease (COPD and asthma in patients suspected of suffering from an obstructive airway disease (OAD in primary care. Methods Cross sectional diagnostic study of 219 adult patients attending 10 general practices for the first time with complaints suspicious for OAD. All patients underwent spirometry and structured medical histories were documented. All patients received whole-body plethysmography (WBP in a lung function laboratory. The reference standard was the Tiffeneau ratio (FEV1/VC received by the spirometric maneuver during examination with WBP. In the event of inconclusive results, bronchial provocation was performed to determine bronchial hyper-responsiveness (BHR. Asthma was defined as a PC20 fall after inhaling methacholine concentration ≤ 16 mg/ml. Results 90 (41.1% patients suffered from asthma, 50 (22.8% suffered from COPD, 79 (36.1% had no OAD. The sensitivity for diagnosing airway obstruction in COPD was 92% (95%CI 80–97; specificity was 84% (95%CI 77–89. The positive predictive value (PPV was 63% (95%CI 51–73; negative predictive value (NPV was 97% (95%CI 93–99. The sensitivity for diagnosing airway obstruction in asthma was 29% (95%CI 21–39; specificity was 90% (95%CI 81–95. PPV was 77% (95%CI 60–88; NPV was 53% (95%CI 45–61. Conclusion COPD can be estimated with high diagnostic accuracy using spirometry. It is also possible to rule in asthma with spirometry. However, asthma can not be ruled out only using spirometry. This diagnostic uncertainty leads to an overestimation of asthma presence. Patients with inconclusive spirometric results should be referred for nitric oxide (NO – measurement and/or bronchial provocation if possible to guarantee accurate diagnosis.

  15. Errors and mistakes in breast ultrasound diagnostics

    Science.gov (United States)

    Jakubowski, Wiesław; Migda, Bartosz

    2012-01-01

    Sonomammography is often the first additional examination performed in the diagnostics of breast diseases. The development of ultrasound imaging techniques, particularly the introduction of high frequency transducers, matrix transducers, harmonic imaging and finally, elastography, influenced the improvement of breast disease diagnostics. Nevertheless, as in each imaging method, there are errors and mistakes resulting from the technical limitations of the method, breast anatomy (fibrous remodeling), insufficient sensitivity and, in particular, specificity. Errors in breast ultrasound diagnostics can be divided into impossible to be avoided and potentially possible to be reduced. In this article the most frequently made errors in ultrasound have been presented, including the ones caused by the presence of artifacts resulting from volumetric averaging in the near and far field, artifacts in cysts or in dilated lactiferous ducts (reverberations, comet tail artifacts, lateral beam artifacts), improper setting of general enhancement or time gain curve or range. Errors dependent on the examiner, resulting in the wrong BIRADS-usg classification, are divided into negative and positive errors. The sources of these errors have been listed. The methods of minimization of the number of errors made have been discussed, including the ones related to the appropriate examination technique, taking into account data from case history and the use of the greatest possible number of additional options such as: harmonic imaging, color and power Doppler and elastography. In the article examples of errors resulting from the technical conditions of the method have been presented, and those dependent on the examiner which are related to the great diversity and variation of ultrasound images of pathological breast lesions. PMID:26675358

  16. Errors and mistakes in breast ultrasound diagnostics

    Directory of Open Access Journals (Sweden)

    Wiesław Jakubowski

    2012-09-01

    Full Text Available Sonomammography is often the first additional examination performed in the diagnostics of breast diseases. The development of ultrasound imaging techniques, particularly the introduction of high frequency transducers, matrix transducers, harmonic imaging and finally, elastography, influenced the improvement of breast disease diagnostics. Neverthe‑ less, as in each imaging method, there are errors and mistakes resulting from the techni‑ cal limitations of the method, breast anatomy (fibrous remodeling, insufficient sensitivity and, in particular, specificity. Errors in breast ultrasound diagnostics can be divided into impossible to be avoided and potentially possible to be reduced. In this article the most frequently made errors in ultrasound have been presented, including the ones caused by the presence of artifacts resulting from volumetric averaging in the near and far field, artifacts in cysts or in dilated lactiferous ducts (reverberations, comet tail artifacts, lateral beam artifacts, improper setting of general enhancement or time gain curve or range. Errors dependent on the examiner, resulting in the wrong BIRADS‑usg classification, are divided into negative and positive errors. The sources of these errors have been listed. The methods of minimization of the number of errors made have been discussed, includ‑ ing the ones related to the appropriate examination technique, taking into account data from case history and the use of the greatest possible number of additional options such as: harmonic imaging, color and power Doppler and elastography. In the article examples of errors resulting from the technical conditions of the method have been presented, and those dependent on the examiner which are related to the great diversity and variation of ultrasound images of pathological breast lesions.

  17. Appendicitis in pregnancy: an ongoing diagnostic dilemma.

    Science.gov (United States)

    Brown, J J S; Wilson, C; Coleman, S; Joypaul, B V

    2009-02-01

    Appendicitis in pregnancy (AIP) is the most common nonobstetric cause of an acute abdomen requiring surgical intervention. Diagnostic difficulties arising from gestational symptoms compound the risk of foetal loss after negative appendicectomy and exponentially increase the risk to mother and foetus with delay in genuine cases. In this article, we investigate the symptoms and signs of AIP and attempt to identify consistent clinical features and review the role of imaging in diagnosis. MEDLINE and PubMed were searched for case-control studies recording preoperative symptoms/signs suggestive of AIP, as well as appendiceal pathology. Combined likelihood and odds ratios (OR) were created for clinical features across homogenous papers. Papers examining the use of laparoscopy, ultrasound (US), computerized tomography (CT) and magnetic resonance imaging (MRI) were assessed qualitatively. Seven papers met the inclusion criteria for the analysis of consistent clinical features (450 patients). The only symptoms or signs significantly associated with a diagnosis of appendicitis were nausea (OR: 2.21, 95%CI: 1.34-3.66), vomiting (OR: 0.82-15.6 range) and peritonism (OR: 1.80, 95%CI: 1.06-3.04). US, CT and MRI have all been used to successfully diagnose AIP. Laparoscopic appendicectomy has been safely undertaken in pregnancy. Appendicitis will continue to challenge the diagnostic acumen of surgeons. Whilst useful, consensus regarding the safety of laparoscopy, CT and MRI in pregnancy is yet to be achieved.

  18. Thyroid stimulating immunoglobulin is often negative in children with Graves' disease.

    Science.gov (United States)

    Rahhal, Samar N; Eugster, Erica A

    2008-11-01

    The diagnosis of Graves' disease (GD) is typically confirmed with a thyroid stimulating immunoglobulin (TSI) titer. While TSI is reported to be positive in >90% of patients with GD, our anecdotal experience suggests that TSI negative GD may be more common in children. To investigate the incidence of TSI negative GD in our population and to compare patients with TSI negative vs TSI positive GD. Charts of children with GD seen in our pediatric endocrinology clinic over the past 5 years were reviewed. Fifty-seven patients with GD were included. TSI was negative in 43% of patients. No significant differences were found in children with TSI negative vs TSI positive GD. In patients with GD, the finding of a negative TSI titer usually creates diagnostic uncertainty. However, the fact that nearly half of our patients with GD were TSI negative suggests that this is common in children.

  19. Novel uses of detonator diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, John R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wilde, Zakary Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tasker, Douglas George [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Francois, Elizabeth Green [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Nakamoto, Teagan Kanakanui Junichi [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Smith, Dalton Kay [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trujillo, Christopher J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-15

    A novel combination of diagnostics is being used to research the physics of detonator initiation. The explosive PETN (Pentaerythritol tetranitrate) commonly used in detonators, is also a piezo-electric material that, when sufficiently shocked, emits an electromagnetic field in the radio frequency (RF) range, along crystal fracture planes. In an effort to capture this RF signal, a new diagnostic was created. A copper foil, used as an RF antenna, was wrapped around a foam fixture encompassing a PETN pellet. Rogowski coils were used to obtain the change in current with respect to time (di/dt) the detonator circuit, in and polyvinylidene difluoride (PVDF) stress sensors were used to capture shockwave arrival time. The goal of these experiments is to use these diagnostics to study the reaction response of a PETN pellet of known particle size to shock loading with various diagnostics including an antenna to capture RF emissions. Our hypothesis is that RF feedback may signify the rate of deflagration to detonation transition (DDT) or lack thereof. The new diagnostics and methods will be used to determine the timing of start of current, bridge burst, detonator breakout timing and RF generated from detonation. These data will be compared to those of currently used diagnostics in order to validate the accuracy of these new methods. Future experiments will incorporate other methods of validation including dynamic radiography, optical initiation and use of magnetic field sensors.

  20. Diagnostic indices for vertiginous diseases

    Directory of Open Access Journals (Sweden)

    Warninghoff Jan-Christian

    2010-10-01

    Full Text Available Abstract Background Vertigo and dizziness are symptoms which are reported frequently in clinical practice. We aimed to develop diagnostic indices for four prevalent vertiginous diseases: benign paroxysmal positional vertigo (BPPV, Menière's disease (MD, vestibular migraine (VM, and phobic postural vertigo (PPV. Methods Based on a detailed questionnaire handed out to consecutive patients presenting for the first time in our dizziness clinic we preselected a set of seven questions with desirable diagnostic properties when compared with the final diagnosis after medical workup. Using exact logistic regression analysis diagnostic scores, each comprising of four to six items that can simply be added up, were built for each of the four diagnoses. Results Of 193 patients 131 questionnaires were left after excluding those with missing consent or data. Applying the suggested cut-off points, sensitivity and specificity were 87.5 and 93.5% for BPPV, 100 and 87.4% for MD, 92.3 and 83.7% for VM, 73.7 and 84.1% for PPV, respectively. By changing the cut-off points sensitivity and specificity can be adjusted to meet diagnostic needs. Conclusions The diagnostic indices showed promising diagnostic properties. Once further validated, they could provide an ease to use and yet flexible tool for screening vertigo in clinical practice and epidemiological research.

  1. Diagnostic indices for vertiginous diseases

    Science.gov (United States)

    2010-01-01

    Background Vertigo and dizziness are symptoms which are reported frequently in clinical practice. We aimed to develop diagnostic indices for four prevalent vertiginous diseases: benign paroxysmal positional vertigo (BPPV), Menière's disease (MD), vestibular migraine (VM), and phobic postural vertigo (PPV). Methods Based on a detailed questionnaire handed out to consecutive patients presenting for the first time in our dizziness clinic we preselected a set of seven questions with desirable diagnostic properties when compared with the final diagnosis after medical workup. Using exact logistic regression analysis diagnostic scores, each comprising of four to six items that can simply be added up, were built for each of the four diagnoses. Results Of 193 patients 131 questionnaires were left after excluding those with missing consent or data. Applying the suggested cut-off points, sensitivity and specificity were 87.5 and 93.5% for BPPV, 100 and 87.4% for MD, 92.3 and 83.7% for VM, 73.7 and 84.1% for PPV, respectively. By changing the cut-off points sensitivity and specificity can be adjusted to meet diagnostic needs. Conclusions The diagnostic indices showed promising diagnostic properties. Once further validated, they could provide an ease to use and yet flexible tool for screening vertigo in clinical practice and epidemiological research. PMID:20973968

  2. Diagnostic and therapeutic approach for acute paraquat intoxication.

    Science.gov (United States)

    Gil, Hyo-wook; Hong, Jung-Rak; Jang, Si-Hyong; Hong, Sae-Yong

    2014-11-01

    Paraquat (PQ) has known negative human health effects, but continues to be commonly used worldwide as a herbicide. Our clinical data shows that the main prognostic factor is the time required to achieve a negative urine dithionite test. Patient survival is a 100% when the area affected by ground glass opacity is preserve kidney function: 1) extracorporeal elimination, 2) intravenous antioxidant administration, 3) diuresis with a fluid, and 4) cytotoxic drugs. In conclusion, this review provides a general overview on the diagnostic procedure and treatment modality of acute PQ intoxication, while focusing on our clinical experience.

  3. Proclus’ View about Negative Theology

    Directory of Open Access Journals (Sweden)

    S Rahimiyan

    2012-09-01

    Full Text Available Negative theology is a modern theological approach that idiomatically implies those theological doctrines which are based on the negative premises and concepts for describing God. Among Greeks, this approach was on its climax in Neo-Platonism. Proclus is one of the Neo-Platonists who lived in fifth century (A.D and was in charge of Athena academy for years. He was the most important Neo-Platonist after Plotinus. In his philosophical system, on the one hand, it is impossible to recognize the first source and, on the other hand, the existence of some principles like the relationship between the creator and the universe, reversion and the way of emanation receiving, requires the knowledge of the first source. It seems that such paradox can be resolved by separating the stages of existence order.

  4. Negation switching invariant signed graphs

    Directory of Open Access Journals (Sweden)

    Deepa Sinha

    2014-04-01

    Full Text Available A signed graph (or, $sigraph$ in short is a graph G in which each edge x carries a value $\\sigma(x \\in \\{-, +\\}$ called its sign. Given a sigraph S, the negation $\\eta(S$ of the sigraph S is a sigraph obtained from S by reversing the sign of every edge of S. Two sigraphs $S_{1}$ and $S_{2}$ on the same underlying graph are switching equivalent if it is possible to assign signs `+' (`plus' or `-' (`minus' to vertices of $S_{1}$ such that by reversing the sign of each of its edges that has received opposite signs at its ends, one obtains $S_{2}$. In this paper, we characterize sigraphs which are negation switching invariant and also see for what sigraphs, S and $\\eta (S$ are signed isomorphic.

  5. Negative ion detachment cross sections

    International Nuclear Information System (INIS)

    Champion, R.L.; Doverspike, L.D.

    1992-10-01

    The authors have measured absolute cross sections for electron detachment and charge exchange for collision of O and S with atomic hydrogen, have investigated the sputtering and photodesorption of negative ions from gas covered surfaces, and have begun an investigation of photon-induced field emission of electrons from exotic structures. Brief descriptions of these activities as well as future plans for these projects are given below

  6. Weak negation in inquisitive semantics

    Czech Academy of Sciences Publication Activity Database

    Punčochář, Vít

    2015-01-01

    Roč. 24, č. 3 (2015), s. 323-355 ISSN 0925-8531 R&D Projects: GA ČR(CZ) GA13-21076S Institutional support: RVO:67985955 Keywords : inquisitive semantics * negation * possible worlds * Fitch-style natural deduction * denial Subject RIV: AA - Philosophy ; Religion Impact factor: 0.450, year: 2015 http://link.springer.com/article/10.1007%2Fs10849-015-9219-2

  7. A Semantic Analysis of Negative Concord

    NARCIS (Netherlands)

    Wouden van der, Ton; Zwarts, Frans

    1993-01-01

    It is not uncommon in natural languages that negation seems to behave in an illogical manner. The general term for the many cases where multiple occurrences of morphologically negative constituents express a single semantic negation is negative concord (Labov 1979). Negative concord may take either

  8. Research priorities for negative emissions

    Science.gov (United States)

    Fuss, S.; Jones, C. D.; Kraxner, F.; Peters, G. P.; Smith, P.; Tavoni, M.; van Vuuren, D. P.; Canadell, J. G.; Jackson, R. B.; Milne, J.; Moreira, J. R.; Nakicenovic, N.; Sharifi, A.; Yamagata, Y.

    2016-11-01

    Carbon dioxide removal from the atmosphere (CDR)—also known as ‘negative emissions’—features prominently in most 2 °C scenarios and has been under increased scrutiny by scientists, citizens, and policymakers. Critics argue that ‘negative emission technologies’ (NETs) are insufficiently mature to rely on them for climate stabilization. Some even argue that 2 °C is no longer feasible or might have unacceptable social and environmental costs. Nonetheless, the Paris Agreement endorsed an aspirational goal of limiting global warming to even lower levels, arguing that climate impacts—especially for vulnerable nations such as small island states—will be unacceptably severe in a 2 °C world. While there are few pathways to 2 °C that do not rely on negative emissions, 1.5 °C scenarios are barely conceivable without them. Building on previous assessments of NETs, we identify some urgent research needs to provide a more complete picture for reaching ambitious climate targets, and the role that NETs can play in reaching them.

  9. Negative Reflecting Meta-Mirrors.

    Science.gov (United States)

    Yang, Rui; Li, Dong; Gao, Dongxing; Zhang, Aofang; Hu, Bowei; Yang, Pei; Lei, Zhenya; Li, Jiacheng

    2017-07-18

    Using the gradient phase discontinuities that meta-mirrors provide, we show that the incident wave can be reflected anomalously with a broad angle range of negative reflections. Such reversed behaviors promote the immediate applications for the planar meta-mirrors to steer the signals more arbitrarily and the convex meta-mirrors to focus and collimate electromagnetic fields. We practically implement these negative reflecting meta-mirrors through an arrangement of subwavelength ring patches and generate the desired phase distribution by also considering the incident angle. Finally, the experiments are carried out to verify the functionality of the convex meta-mirror firstly, and the performances of the planar meta-mirror are also tested by further building up a dual reflector system with the demonstration of obtaining the plane wave from the convex meta-mirror and then having the well collimated beam negative reflected by the planar meta-mirror. The proposed design should be readily applicable to a wide range of electromagnetic problems, especially for devising smart planar illusion devices, and highly directive antennas mounting on convex surfaces of various platforms.

  10. Negative-Pressure Pulmonary Edema.

    Science.gov (United States)

    Bhattacharya, Mallar; Kallet, Richard H; Ware, Lorraine B; Matthay, Michael A

    2016-10-01

    Negative-pressure pulmonary edema (NPPE) or postobstructive pulmonary edema is a well-described cause of acute respiratory failure that occurs after intense inspiratory effort against an obstructed airway, usually from upper airway infection, tumor, or laryngospasm. Patients with NPPE generate very negative airway pressures, which augment transvascular fluid filtration and precipitate interstitial and alveolar edema. Pulmonary edema fluid collected from most patients with NPPE has a low protein concentration, suggesting hydrostatic forces as the primary mechanism for the pathogenesis of NPPE. Supportive care should be directed at relieving the upper airway obstruction by endotracheal intubation or cricothyroidotomy, institution of lung-protective positive-pressure ventilation, and diuresis unless the patient is in shock. Resolution of the pulmonary edema is usually rapid, in part because alveolar fluid clearance mechanisms are intact. In this review, we discuss the clinical presentation, pathophysiology, and management of negative-pressure or postobstructive pulmonary edema. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  11. Two negations for the price of one

    Directory of Open Access Journals (Sweden)

    Rosalind Thornton

    2016-11-01

    Full Text Available Standard English is typically described as a double negation language. In double negation ­languages, each negative marker contributes independent semantic force. Two negations in the same clause usually cancel each other out, resulting in an affirmative sentence. Other dialects of English permit negative concord. In negative concord sentences, the two negative markers yield a single semantic negation. This paper explores how English-speaking children interpret sentences with more than one negative element, in order to assess whether their early grammar allows negative concord. According to Zeijlstra’s (2004 typological generalization, if a language has a negative syntactic head, it will be a negative concord language. Since Standard English is often analysed as having a negative head, it represents an apparent exception to Zeijlstra’s ­generalization. This raises the intriguing possibility that initially, children recognize that English has a negative head (i.e., 'n’t' and, therefore, assign negative concord interpretations to sentences with two negations, despite the absence of evidence for this interpretation in the adult input. The present study investigated this possibility in a comprehension study with 20 3- to 5-year-old ­children and a control group of 15 adults. The test sentences were presented in contexts that made them amenable to either a double negation or a negative concord interpretation. As expected, the adult participants assigned the double negation interpretation of the test sentences the majority of the time. In contrast, the child participants assigned the alternative, negative concord interpretation the majority of the time. Children must jettison the negative concord interpretation of sentences with two negative markers, and acquire a double negation interpretation. We propose that the requisite positive evidence is the appearance of negative expressions like 'nothing 'in object position. Because such

  12. Modern parameterization and explanation techniques in diagnostic decision support system: a case study in diagnostics of coronary artery disease.

    Science.gov (United States)

    Kukar, Matjaž; Kononenko, Igor; Grošelj, Ciril

    2011-06-01

    Coronary artery disease has been described as one of the curses of the western world, as it is one of its most important causes of mortality. Therefore, clinicians seek to improve diagnostic procedures, especially those that allow them to reach reliable early diagnoses. In the clinical setting, coronary artery disease diagnostics are typically performed in a sequential manner. The four diagnostic levels consist of evaluation of (1) signs and symptoms of the disease and electrocardiogram at rest, (2) sequential electrocardiogram testing during the controlled exercise, (3) myocardial perfusion scintigraphy, and (4) finally coronary angiography, that is considered as the "gold standard" reference method. Our study focuses on improving diagnostic performance of the third, virtually non-invasive, diagnostic level. Myocardial scintigraphy results in a series of medical images that are obtained by relatively inexpensive means. In clinical practice, these images are manually described (parameterized) by expert physicians. In the paper we present an innovative alternative to manual image evaluation-an automatic image parameterization on multiple resolutions, based on texture description with specialized association rules. Extracted image parameters are combined into more informative composite parameters by means of principal component analysis, and finally used to build automatic classifiers with machine learning methods. Our experiments with synthetic datasets show that association-rule-based multi-resolution image parameterization works very well for scintigraphic images of the heart. In coronary artery disease diagnostics we confirm these results as our approach significantly improves on clinical results in terms of diagnostic performance. We improve diagnostic accuracy by 17%, specificity by 12% and sensitivity by 22%. We also significantly improve the number of reliably diagnosed patients by 19% for positive diagnoses, and 16% for negative diagnoses, so that no costly

  13. Far infrared fusion plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-01-01

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer's importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA's CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  14. [Alexithymia in negative symptom and non-negative symptom schizophrenia].

    Science.gov (United States)

    Nkam, I; Langlois-Thery, S; Dollfus, S; Petit, M

    1997-01-01

    Coined by Sifneos in 1972, alexithymia refers to a relative narrowing in emotional functioning, an inability to find appropriate words to describe their emotions and, a poverty of fantasy life. Although initially described in the context of psychosomatic illness, alexithymic characteristics may be observed in patients with a wide range of medical and psychiatric disorders: Parkinson disease, depression, anxiety, substance abuse and eating disorders. Flattening of affect and poverty of speech, major negative symptoms, referred to chronic schizophrenia: there is a lack of outward display of emotion. Accordingly, some disturbances of alexithymia's scores would be expected in schizophrenic patients. The purpose of this study was to estimate and compare the prevalence of alexithymia in deficit and non-deficit schizophrenia. The term "deficit symptoms" may be used as Carpenter, to refer specifically to those negative symptoms that are not considered secondary. The influence of patients' symptoms has also been studied on alexithymia scores: negative and positive symptoms of schizophrenia, depression, anxiety, anhedonia and effects of neuroleptics. Twenty-five patients, meeting DSM III-R criteria for schizophrenia have been studied. All of them treated by neuroleptics, were in a stable clinical status for at least one month. The patients have been categorized into deficit (n = 12) and non-deficit (n = 13) subgroups by one trained psychiatrist (SD), using the Schedule for the Deficit Syndrome. The subjects have been assessed by the same rater (IN), blind to deficit status, using six rating scales: Beth Israel Questionnaire (BIQ) and Toronto Alexithymia Scale (TAS) for alexithymia, Positive and Negative Syndrome Scale (PANSS), Montgomery and Asberg Depression Rating Scale (MADRS), revised Physical Anhedonia Scale (PAS), and finally, Extrapyramidal Symptom Rating Scale (ESRS). Using TAS, alexithymic characteristics were more prevalent in the deficit subgroup as compared to

  15. Diagnostic uncertainty and recall bias in chronic low back pain.

    Science.gov (United States)

    Serbic, Danijela; Pincus, Tamar

    2014-08-01

    Patients' beliefs about the origin of their pain and their cognitive processing of pain-related information have both been shown to be associated with poorer prognosis in low back pain (LBP), but the relationship between specific beliefs and specific cognitive processes is not known. The aim of this study was to examine the relationship between diagnostic uncertainty and recall bias in 2 groups of chronic LBP patients, those who were certain about their diagnosis and those who believed that their pain was due to an undiagnosed problem. Patients (N=68) endorsed and subsequently recalled pain, illness, depression, and neutral stimuli. They also provided measures of pain, diagnostic status, mood, and disability. Both groups exhibited a recall bias for pain stimuli, but only the group with diagnostic uncertainty also displayed a recall bias for illness-related stimuli. This bias remained after controlling for depression and disability. Sensitivity analyses using grouping by diagnosis/explanation received supported these findings. Higher levels of depression and disability were found in the group with diagnostic uncertainty, but levels of pain intensity did not differ between the groups. Although the methodology does not provide information on causality, the results provide evidence for a relationship between diagnostic uncertainty and recall bias for negative health-related stimuli in chronic LBP patients. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  16. CRISIS-DIAGNOSTICS IN ANTI-CRISIS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Gavrylenko Valentina

    2018-01-01

    Full Text Available Introduction. In today’s conditions of a changing market environment, uncertainty and risk, one of the main tasks of management is the timely detection of crisis symptoms and the development of measures aimed at preventing their negative impact on the activities of the enterprise. The purpose of this article is to determine the accounting and analytical information for the development of the model KRIZІS-diagnostics and ensure the effectiveness of its functioning in anti-crisis management. Results. The analysis of definition of the concept «KRIZІS-diagnostics» in the scientific literature is carried out. Multi-factor models for assessing the financial status and the diagnostics of enterprises bankruptcy for different countries are presented. The specified classification of management KRIZІS-diagnostics is specified. The stages and tasks of KRIZІS-diagnostics are determined. The sources of information, which are determinants of the early symptoms of the crisis and necessary for KRIZІS-diagnostics are indicated and the characteristic is also given. Qualitative and quantitative indicators that characterize the business processes of the enterprise and can be used to analyze the state of the enterprise in a changing environment for preventing the crisis are determined. Conclusions. This approach of identifying crisis symptoms in business processes is the basis for managing an enterprise to make strategic management decisions in order to prevent a crisis at its early stages. The development of KRIZІS-diagnostics as an information provision for anti-crisis management is the direction of further research.

  17. A Survey on the Usage and Demand of Medical Radioisotope and Radiopharmaceuticals in Malaysia

    International Nuclear Information System (INIS)

    Muhammad Fakhrurazi Ahmad Fadzil; Siti Selina Abdul Hamid; Siti Najila Mohd Janib; Azahari Kasbollah; Syed Asraf Fahlawi Wafa

    2016-01-01

    Medical radioisotope is a small quantity of radioactive substance used for the purpose of diagnostic and therapy of various diseases. In Malaysia, the emerging of new nuclear medicine centers or institutions in both government and private sectors rose abruptly for the past few years. Currently, there are no data available on the usage and demand of these medical radioisotope or radiopharmaceuticals. The aim of this study is to assess current medical radioisotopes and radiopharmaceuticals usage and also to provide data on current medical radioisotope and radiopharmaceuticals demand for both private and government hospitals or institutions in Malaysia. A survey for a period of 3 months was conducted across Malaysia. The survey was divided into five (5) main parts and it was distributed among health care professionals involved working with medical radioisotope and radiopharmaceuticals in private, government and university based hospitals or institutions and was distributed manually either by hand, mail or e-mail. Data is presented in either pie chart or bar chart. Survey results found out that the highest demand and the highest usage among all radioisotopes are Technetium-99m and radioiodine isotopes such as the iodine-131, iodine-131 MIBG, iodine-123 and iodine-123 MIBG. Technetium-99m is the backbone of nuclear medicine whereby more than 80 % of Nuclear Medicine services utilize this radioisotope. Technetium-99m supply chain is unstable globally and in coming future, two main reactors that produce 60 % of world Molybdenum-99 will shut down and the supply of molybdenum-99 will be disrupted. In radioiodine services, currently, Iodine-123 cannot be obtained in Malaysia and neighboring countries due to its short half-life. Iodine-123 is useful in diagnostic of thyroid related diseases. As for PET services, the highest demands are F-18 FDG and gallium-68 Generator. It is important for Malaysia to self-produced medical radioisotope and radiopharmaceuticals to meet the

  18. Saliva as a diagnostic medium.

    Science.gov (United States)

    Pink, Richard; Simek, Jiri; Vondrakova, Jana; Faber, Edgar; Michl, Petr; Pazdera, Jindrich; Indrak, Karel

    2009-06-01

    This is a review of current knowledge on the use of saliva, gingival cervical fluid and mucosal transudate in the detection of some oral and systemic diseases as well as drugs. Oral fluid is a diagnostic medium that can be easily collected and with minimal invasion but it has been neglected in the past. Today, saliva is being used more often to diagnose: HIV virus, oro-facial and systemic tumors, cardiovascular disease and in detecting addictive substances. Neutropil levels in saliva may also indicate successful bone marrow transplant. Oral fluid is now systematically being researched and oral fluid analysis is being compared with the analysis of other diagnostic media such as blood and urine. A number of recent studies have focused on oncogenic marker detection and its monitoring in saliva. The latest clinical and laboratory findings on diagnostic markers of oropharyngeal carcinoma in oral fluid could be the beginning of their wider use as a diagnostic medium. Oral fluid can also be also used to diagnose other malignancies such as breast cancer which was one of the first malignant tumors to be detected using genetic protein biomarkers. Raised levels of CA15-3 and the epidermal growth factor (EGF) receptor have been found in patients with breast cancer and elevated levels of CA 125 and the glycoprotein complex in the saliva of ovarian cancer patients. Doubtless, the diagnostic value of saliva, aided by current technological development will increase rapidly in the near future.

  19. Neurologic emergencies in HIV-negative immunosuppressed patients.

    Science.gov (United States)

    Guzmán-De-Villoria, J A; Fernández-García, P; Borrego-Ruiz, P J

    HIV-negative immunosuppressed patients comprise a heterogeneous group including transplant patients, patients undergoing treatment with immunosuppressors, uremic patients, alcoholics, undernourished patients, diabetics, patients on dialysis, elderly patients, and those diagnosed with severe or neoplastic processes. Epileptic seizures, focal neurologic signs, and meningoencephalitis are neurologic syndromes that require urgent action. In most of these situations, neuroimaging tests are necessary, but the findings can be different from those observed in immunocompetent patients in function of the inflammatory response. Infectious disease is the first diagnostic suspicion, and the identification of an opportunistic pathogen should be oriented in function of the type and degree of immunosuppression. Other neurologic emergencies include ischemic stroke, cerebral hemorrhage, neoplastic processes, and pharmacological neurotoxicity. This article reviews the role of neuroimaging in HIV-negative immunodepressed patients with a neurologic complication that requires urgent management. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Diagnostics for the ATA beam propagation experiments

    International Nuclear Information System (INIS)

    Fessenden, T.J.; Atchison, W.L.; Barletta, W.A.

    1981-11-01

    This report contains a discussion of the diagnostics required for the beam propagation experiment to be done with the ATA accelerator. Included are a list of the diagnostics needed; a description of the ATA experimental environment; the status of beam diagnostics available at Livermore including recent developments, and a prioritized list of accelerator and propagation diagnostics under consideration or in various stages of development

  1. Diagnostics for the ATA beam propagation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fessenden, T.J.; Atchison, W.L.; Barletta, W.A.

    1981-11-01

    This report contains a discussion of the diagnostics required for the beam propagation experiment to be done with the ATA accelerator. Included are a list of the diagnostics needed; a description of the ATA experimental environment; the status of beam diagnostics available at Livermore including recent developments, and a prioritized list of accelerator and propagation diagnostics under consideration or in various stages of development.

  2. AUTOMATED PEDAGOGICAL DIAGNOSTICS IN MODERN UNIVERSITY

    Directory of Open Access Journals (Sweden)

    Oleksandr H. Kolhatin

    2010-08-01

    Full Text Available Realisation of the pedagogical assessment functions at using of automated pedagogical diagnostics systems in university instruction process is considered. Pedagogical diagnostics software requirements are determined on the base of automated pedagogical diagnostics systems classifications analysis according to didactical aim of the diagnostics.

  3. Superluminal travel requires negative energies

    OpenAIRE

    Olum, Ken D.

    1998-01-01

    I investigate the relationship between faster-than-light travel and weak-energy-condition violation, i.e., negative energy densities. In a general spacetime it is difficult to define faster-than-light travel, and I give an example of a metric which appears to allow superluminal travel, but in fact is just flat space. To avoid such difficulties, I propose a definition of superluminal travel which requires that the path to be traveled reach a destination surface at an earlier time than any neig...

  4. Imagery mismatch negativity in musicians.

    Science.gov (United States)

    Herholz, Sibylle C; Lappe, Claudia; Knief, Arne; Pantev, Christo

    2009-07-01

    The present study investigated musical imagery in musicians and nonmusicians by means of magnetoencephalography (MEG). We used a new paradigm in which subjects had to continue familiar melodies in their mind and then judged if a further presented tone was a correct continuation of the melody. Incorrect tones elicited an imagery mismatch negativity (iMMN) in musicians but not in nonmusicians. This finding suggests that the MMN component can be based on an imagined instead of a sensory memory trace and that imagery of music is modulated by musical expertise.

  5. Diagnostic accuracy in virtual dermatopathology

    DEFF Research Database (Denmark)

    Mooney, E.; Kempf, W.; Jemec, G.B.E.

    2012-01-01

    Background Virtual microscopy is used for teaching medical students and residents and for in-training and certification examinations in the United States. However, no existing studies compare diagnostic accuracy using virtual slides and photomicrographs. The objective of this study was to compare...... diagnostic accuracy of dermatopathologists and pathologists using photomicrographs vs. digitized images, through a self-assessment examination, and to elucidate assessment of virtual dermatopathology. Methods Forty-five dermatopathologists and pathologists received a randomized combination of 15 virtual...... slides and photomicrographs with corresponding clinical photographs and information in a self-assessment examination format. Descriptive data analysis and comparison of groups were performed using a chi-square test. Results Diagnostic accuracy in dermatopathology using virtual dermatopathology...

  6. Fetal exposure in diagnostic radiology

    International Nuclear Information System (INIS)

    Baker, M.L.; Vandergrift, J.F.; Dalrymple, G.V.

    1979-01-01

    The problem of possible radiation damage to the fetus or embryo as a result of diagnostic radiography during pregnancy, particularly in the early stages, is discussed. Recommendations of therapeutic abortion after fetal exposure require an adequate knowledge of the doses involved. In the absence of actual dose measurements or estimates, approximate exposure levels may be determined from the literature. A summary of published values for radiography involving the lower abdomen is given. Data is also presented from a series of fetal exposures resulting mostly from routine diagnostic radiography when pregnancy was not known at the time but was established later. Results of actual dose measurements using a phantom and of dose calculations based on published values are in reasonable agreement indicating that literature values of dose provide a satisfactory alternative to measurement. These data suggest that diagnostic radiography rarely, if ever, results in fetal exposures high enough to justify therapeutic abortion. (author)

  7. Enhanced NIF neutron activation diagnostics.

    Science.gov (United States)

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  8. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  9. Molecular diagnostics of neurodegenerative disorders.

    Science.gov (United States)

    Agrawal, Megha; Biswas, Abhijit

    2015-01-01

    Molecular diagnostics provide a powerful method to detect and diagnose various neurological diseases such as Alzheimer's and Parkinson's disease. The confirmation of such diagnosis allows early detection and subsequent medical counseling that help specific patients to undergo clinically important drug trials. This provides a medical pathway to have better insight of neurogenesis and eventual cure of the neurodegenerative diseases. In this short review, we present recent advances in molecular diagnostics especially biomarkers and imaging spectroscopy for neurological diseases. We describe advances made in Alzheimer's disease (AD), Parkinson's disease (PD), Amyotrophic lateral sclerosis (ALS) and Huntington's disease (HD), and finally present a perspective on the future directions to provide a framework for further developments and refinements of molecular diagnostics to combat neurodegenerative disorders.

  10. Integration of diagnostics in ITER buildings

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, Arun Prakash, E-mail: arun.prakash@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Walker, Chris; Mita, Y.; Patisson, L.; Kuehn, I.; Cantone, B. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    ITER Diagnostic systems extend from plasma to the various diagnostic areas where they are controlled and acquired data is processed. Diagnostic equipment is found at three levels of the Tokamak Building, within 21 port cells, the gallery and also at three levels of Diagnostic Area. Diagnostic equipment is also located in other buildings, such as the Hot Cell Facility for neutron testing and port plug receipt and preparation. This paper describes the relationship of the ITER Diagnostics with the Buildings and highlights the design requirement and solutions of satisfying this interface acceptably to diagnostic and building performance.

  11. Calibration issues for neutron diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sadler, G.J. [JET Joint Undertaking, Abingdon (United Kingdom); Adams, J.M. [AEA Technology, Harwell (United Kingdom); Barnes, C.W. [Los Alamos National Lab., NM (United States)] [and others

    1997-12-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next.

  12. The negation phenomenon. Aquiring French negation by Romanian native speakers

    Directory of Open Access Journals (Sweden)

    Liliana-Sonia IONESCU

    2011-01-01

    Full Text Available The present paper sets out some guidelines for a strategy based on the comparison ofRomanian and French and outlines some ways of learning the French negation by the nativespeakers of Romanian; the paper also points out a number of difficulties they face in assimilatingnegation in French. By highlighting some difficulties in assimilating the new language, based on thecontrastive analysis, these must be taken into consideration and ameliorated, to prevent theoccurrence of the default errors.The process of mastering a language is highly conditioned by the practicing of the studiedlanguage, i.e. a system of applications / structural exercises based on similarity and oppositionwithin a language, to allow the formation of spontaneous speech and understanding skills.

  13. An edge over diagnostic setup

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2017-01-01

    Full Text Available Diagnostic setup proposed by H.D. Kingsley serves as a practical aid in treatment planning and diagnosis. These setups have some inherent shortcomings. A simple technique of duplication of the setups in dental stone can solve problems encountered before as well as provide many other advantages over the conventional procedure. The diagnostic setup is prepared by the conventional method [Figure 1]. An alginate impression is then taken of the setups and poured in dental stone to obtain the derived treatment model [Figure 2]. The same setup can now be further modified for alternate lines of treatment. Subsequently models could then be obtained as required [Figure 3].

  14. Diagnostic imaging in internal medicine

    International Nuclear Information System (INIS)

    Eisenberg, R.L.

    1985-01-01

    This book examines medical diagnostic techniques. Topics considered include biological considerations in the approach to clinical medicines; infectious diseases; disorders of the heart; disorders of the vascular system; disorders of the respiratory system; diseases of the kidneys and urinary tract; disorders of the alimentary tract; disorders of the hepatobiliary system and pancreas; disorders of the hematopoietic system; disorders of bone and bone mineralization; disorders of the joints, connective tissues, and striated muscles; disorders of the nervous system; miscellaneous disorders; and procedures in diagnostic imaging

  15. Differential diagnostics of bullous dermatoses

    Directory of Open Access Journals (Sweden)

    A. A. Kubanov

    2016-01-01

    Full Text Available Bullous dermatoses are the diseases characterized by vesication and erosion of skin and/or mucos coats, production of autoantibodies against the structural components of epidermis and/or derma. The most frequent diseases of these disorders are pemphigus, bullous pemphigoid, dermatitis herpetiformis, beningn familial chronic pemphigus (Gougerot Hailey-Hailey disease.Diagnostics of bullous dermatoses is based on assessement of clinical signs, results of cytological and histological studies and immunological tests. However none of the current diagnostic methods allows to reveal bullous dermatosis severally and with absolute certainty. Consequently it is necessary to perform wide range of clinical and laboratory tests for early diagnosis and treatment order.

  16. First Wall and Operational Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lasnier, C; Allen, S; Boedo, J; Groth, M; Brooks, N; McLean, A; LaBombard, B; Sharpe, J; Skinner, C; Whyte, D; Rudakov, D; West, W; Wong, C

    2006-06-19

    In this chapter we review numerous diagnostics capable of measurements at or near the first wall, many of which contribute information useful for safe operation of a tokamak. There are sections discussing infrared cameras, visible and VUV cameras, pressure gauges and RGAs, Langmuir probes, thermocouples, and erosion and deposition measurements by insertable probes and quartz microbalance. Also discussed are dust measurements by electrostatic detectors, laser scattering, visible and IR cameras, and manual collection of samples after machine opening. In each case the diagnostic is discussed with a view toward application to a burning plasma machine such as ITER.

  17. First Wall and Operational Diagnostics

    International Nuclear Information System (INIS)

    Lasnier, C; Allen, S; Boedo, J; Groth, M; Brooks, N; McLean, A; LaBombard, B; Sharpe, J; Skinner, C; Whyte, D; Rudakov, D; West, W; Wong, C

    2006-01-01

    In this chapter we review numerous diagnostics capable of measurements at or near the first wall, many of which contribute information useful for safe operation of a tokamak. There are sections discussing infrared cameras, visible and VUV cameras, pressure gauges and RGAs, Langmuir probes, thermocouples, and erosion and deposition measurements by insertable probes and quartz microbalance. Also discussed are dust measurements by electrostatic detectors, laser scattering, visible and IR cameras, and manual collection of samples after machine opening. In each case the diagnostic is discussed with a view toward application to a burning plasma machine such as ITER

  18. Diagnostic imaging in bovine orthopedics.

    Science.gov (United States)

    Kofler, Johann; Geissbühler, Urs; Steiner, Adrian

    2014-03-01

    Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  20. Optimization of negative ion accelerators

    International Nuclear Information System (INIS)

    Pamela, J.

    1991-01-01

    We have started to study negative ion extraction and acceleration systems in view of designing a 1 MeV D - accelerator. This study is being made with a two-Dimensional code that has been specifically developed in our laboratory and validated by comparison to three sets of experimental data. We believe that the criteria for negative ion accelerator design optimization should be: (i) to provide the best optics; (ii) to reduce the power load on the extraction grid; (iii) to allow operation with low electric fields in order to reduce the problem of breakdowns. We show some results of optics calculations performed for two systems that will be operational in the next months: the CEA-JAERI collaboration at Cadarache and the european DRAGON experiment at Culham. Extrapolations to higher energies of 500 to 1100 keV have also been conducted. All results indicate that the overall accelerator length, whatever be the number of gaps, is constrained by space charge effects (Child-Langmuir). We have combined this constraint with high-voltage hold-off empirical laws. As a result, it appears that accelerating 10 mA/cm 2 of D - at 1 MeV with good optics, as required for NET or ITER, is close to the expected limit of high-voltage hold-off

  1. Negative regulators of cell proliferation

    Science.gov (United States)

    Johnson, T. C.; Spooner, B. S. (Principal Investigator)

    1994-01-01

    Cell proliferation is governed by the influence of both mitogens and inhibitors. Although cell contact has long been thought to play a fundamental role in cell cycling regulation, and negative regulators have long been suspected to exist, their isolation and purification has been complicated by a variety of technical difficulties. Nevertheless, over recent years an ever-expanding list of putative negative regulators have emerged. In many cases, their biological inhibitory activities are consistent with density-dependent growth inhibition. Most likely their interactions with mitogenic agents, at an intracellular level, are responsible for either mitotic arrest or continued cell cycling. A review of naturally occurring cell growth inhibitors is presented with an emphasis on those factors shown to be residents of the cell surface membrane. Particular attention is focused on a cell surface sialoglycopeptide, isolated from intact bovine cerebral cortex cells, which has been shown to inhibit the proliferation of an unusually wide range of target cells. The glycopeptide arrest cells obtained from diverse species, both fibroblasts and epithelial cells, and a broad variety of transformed cells. Signal transduction events and a limited spectrum of cells that are refractory to the sialoglycopeptide have provided insight into the molecular events mediated by this cell surface inhibitor.

  2. Serotonin, inhibition, and negative mood.

    Directory of Open Access Journals (Sweden)

    Peter Dayan

    2008-02-01

    Full Text Available Pavlovian predictions of future aversive outcomes lead to behavioral inhibition, suppression, and withdrawal. There is considerable evidence for the involvement of serotonin in both the learning of these predictions and the inhibitory consequences that ensue, although less for a causal relationship between the two. In the context of a highly simplified model of chains of affectively charged thoughts, we interpret the combined effects of serotonin in terms of pruning a tree of possible decisions, (i.e., eliminating those choices that have low or negative expected outcomes. We show how a drop in behavioral inhibition, putatively resulting from an experimentally or psychiatrically influenced drop in serotonin, could result in unexpectedly large negative prediction errors and a significant aversive shift in reinforcement statistics. We suggest an interpretation of this finding that helps dissolve the apparent contradiction between the fact that inhibition of serotonin reuptake is the first-line treatment of depression, although serotonin itself is most strongly linked with aversive rather than appetitive outcomes and predictions.

  3. Exploring Chemistry Student Teachers’ Diagnostic Competence—A Qualitative Cross-Level Study

    Directory of Open Access Journals (Sweden)

    Yannik Tolsdorf

    2017-12-01

    Full Text Available Diagnostic competence is an important skill of professional teachers and is a part of Pedagogical Content Knowledge (PCK. Because increasing heterogeneity and diversity characterize our schools, diagnostic competence plays a prominent role in teacher pre- and in-service courses. At our university, two modules are focused on examining student teachers’ diagnostic competence in chemistry. The present paper describes a cross-level case study analyzing three groups of student teachers in different phases of their university teacher training program. The study is based on a qualitative research study with a total of 108 participants. The results show both positive and negative developments in teacher trainees’ diagnostic competence. They show that attitudes and beliefs about heterogeneity can be changed from a rather negative viewpoint to a more positive one. The results will be presented and discussed below. Suggestions for further development will be given.

  4. Negative captopril renography on patients with renin mediated hypertension due to page kidney and reninoma

    Energy Technology Data Exchange (ETDEWEB)

    Yung, B.C.K. [Department of Radiology and Organ Imaging, United Christian Hospital, 130, Hip Wo Street, Kwun Tong, Kowloon, Hong Kong (China); Wong, K.W. [Department of Radiology, Princess Margaret Hospital, 2-10, Princess Margaret Hospital Road, Lai Chi Kok, Kowloon, Hong Kong (China); Fan, W.C. [Department of Radiology and Organ Imaging, United Christian Hospital, 130, Hip Wo Street, Kwun Tong, Kowloon, Hong Kong (China); Chan, J.C.S. [Department of Radiology and Organ Imaging, United Christian Hospital, 130, Hip Wo Street, Kwun Tong, Kowloon, Hong Kong (China); Lo, S.S.S. [Department of Radiology and Organ Imaging, United Christian Hospital, 130, Hip Wo Street, Kwun Tong, Kowloon, Hong Kong (China)

    1999-07-01

    Through a mechanism similar to renal artery stenosis, patients with reninoma and page kidney also suffered from renin mediated hypertension. Captopril renograms performed on our patients with the latter two conditions, however, did not yield diagnostic findings. Therefore, equivocal or negative captopril renography cannot serve to rule out conditions with elevated renin other than renal artery stenosis.

  5. Negative captopril renography on patients with renin mediated hypertension due to page kidney and reninoma

    International Nuclear Information System (INIS)

    Yung, B.C.K.; Wong, K.W.; Fan, W.C.; Chan, J.C.S.; Lo, S.S.S.

    1999-01-01

    Through a mechanism similar to renal artery stenosis, patients with reninoma and page kidney also suffered from renin mediated hypertension. Captopril renograms performed on our patients with the latter two conditions, however, did not yield diagnostic findings. Therefore, equivocal or negative captopril renography cannot serve to rule out conditions with elevated renin other than renal artery stenosis

  6. Diagnostic Biomarkers for Posttraumatic Stress Disorder (PTSD): Promising Horizons from Translational Neuroscience Research

    OpenAIRE

    Michopoulos, Vasiliki; Norrholm, Seth Davin; Jovanovic, Tanja

    2015-01-01

    Posttraumatic stress disorder (PTSD) is a heterogeneous disorder that affects individuals exposed to trauma (e.g., combat, interpersonal violence, and natural disasters). Although its diagnostic features have been recently re-classified with the emergence of the Diagnostic and Statistical Manual for Mental Disorders, Fifth Edition (DSM-5), the disorder remains characterized by hyperarousal, intrusive reminders of the trauma, avoidance of trauma-related cues, and negative cognition and mood. T...

  7. Diagnostic errors in pediatric radiology

    International Nuclear Information System (INIS)

    Taylor, George A.; Voss, Stephan D.; Melvin, Patrice R.; Graham, Dionne A.

    2011-01-01

    Little information is known about the frequency, types and causes of diagnostic errors in imaging children. Our goals were to describe the patterns and potential etiologies of diagnostic error in our subspecialty. We reviewed 265 cases with clinically significant diagnostic errors identified during a 10-year period. Errors were defined as a diagnosis that was delayed, wrong or missed; they were classified as perceptual, cognitive, system-related or unavoidable; and they were evaluated by imaging modality and level of training of the physician involved. We identified 484 specific errors in the 265 cases reviewed (mean:1.8 errors/case). Most discrepancies involved staff (45.5%). Two hundred fifty-eight individual cognitive errors were identified in 151 cases (mean = 1.7 errors/case). Of these, 83 cases (55%) had additional perceptual or system-related errors. One hundred sixty-five perceptual errors were identified in 165 cases. Of these, 68 cases (41%) also had cognitive or system-related errors. Fifty-four system-related errors were identified in 46 cases (mean = 1.2 errors/case) of which all were multi-factorial. Seven cases were unavoidable. Our study defines a taxonomy of diagnostic errors in a large academic pediatric radiology practice and suggests that most are multi-factorial in etiology. Further study is needed to define effective strategies for improvement. (orig.)

  8. Recent trend of diagnostic radiology

    International Nuclear Information System (INIS)

    Kim, S.Y.; Kim, H.K.

    1979-01-01

    Present status and recent trend of diagnostic radiology have been reviewed. The interrelationships and Characteristics of various fields of radiology such as computed tomography, X-ray radiology, and nuclear medicine were discussed. The mevit of computed tomography and the promising use of short lived, accelerator produced radionuclides, and radiotherapy in nuclear medicine were emphasized. (author)

  9. Local Sensitivity and Diagnostic Tests

    NARCIS (Netherlands)

    Magnus, J.R.; Vasnev, A.L.

    2004-01-01

    In this paper we confront sensitivity analysis with diagnostic testing.Every model is misspecified, but a model is useful if the parameters of interest (the focus) are not sensitive to small perturbations in the underlying assumptions. The study of the e ect of these violations on the focus is

  10. EAMJ Diagnostic April 10.indd

    African Journals Online (AJOL)

    2010-04-04

    Apr 4, 2010 ... Philadelphia Pensylvania, 1992: 317 - 350. 5. Coleman, D. V. and Chapman, P. A. Editors: Clinical Cytopathology. Butterworth and Company. (Publishers) Ltd. 1989: 359 - 362. 6. Waters, E. and Amstrong, J. Disorders of the liver. In: Gray E., Ed. Diagnostic Cytopathology. Edinburgh,. Churchill Livingstone.

  11. Axial diagnostic package for Z

    International Nuclear Information System (INIS)

    Nash, T.J.; Derzon, M.S.; Chandler, G.

    1998-06-01

    The authors have developed and fielded an axial diagnostic package for the 20 MA, 100 ns, z-pinch driver Z. The package is used to diagnose dynamic hohlraum experiments which require an axial line of sight. The heart of the package is a reentrant cone originally used to diagnose ion-beam-driven hohlraums on PBFA-H. It has one diagnostic line of sight at 0 degrees, 4 at 6 degrees, and 4 at 9 degrees. In addition it has a number of viewing, alignment, and vacuum feedthrough ports. The front of the package sits approximately 5 feet from the pinch. This allows much closer proximity to the pinch, with inherently better resolution and signal, than is presently possible in viewing the pinch from the side. Debris that is preferentially directed along the axis is mitigated by two apertures for each line of sight, and by fast valves and imaging pinholes or cross slits for each diagnostic. In the initial run with this package they fielded a time resolved pinhole camera, a five-channel pinhole-apertured x-ray diode array, a bolometer, a spatially resolved time-integrated crystal spectrometer, and a spatially and temporally resolved crystal spectrometer. They present data obtained from these diagnostics in the dynamic hohlraum research conducted on Z

  12. Diagnostic imaging of exotic pets

    International Nuclear Information System (INIS)

    Silverman, S.

    1993-01-01

    Radiographic, ultrasonographic, and computed tomographic (CT) imaging are important diagnostic modalities in exotic pets. The use of appropriate radiographic equipment, film-screen combinations, and radiographic projections enhances the information obtained from radiographs. Both normal findings and common radiographic abnormalities are discussed. The use of ultrasonography and CT scanning for exotic small mammals and reptiles is described

  13. Cell Analysis and Early Diagnostics

    NARCIS (Netherlands)

    Subramaniam, Vinod; Jones, Val

    2006-01-01

    In an era of aging populations and rising health-care costs, the shift of medical paradigms towards rapid, accurate, early diagnoses of diseases is inevitable. In addition to further development of ultrasensitive in vitro tests, the focus of attention in both diagnostics and the early drug discovery

  14. FEL diagnostics and user control

    NARCIS (Netherlands)

    Knippels, G.M.H.; van der Meer, A. F. G.

    1998-01-01

    The most recent upgrades and improvements to the free-electron laser (FEL) facility FELIX are presented. Special attention is paid to the improved beam-handling and diagnostic station. In this evacuated beam station a device is implemented that is capable of selecting single micropulses with

  15. Diagnostic imaging of shoulder impingement

    International Nuclear Information System (INIS)

    Merl, T.; Weinhardt, H.; Oettl, G.; Lenz, M.; Riel, K.A.

    1996-01-01

    Magnetic resonance imaging is a method that has been advancing in the last few years to the modality of choice for diagnostic evaluation of the bone joints, as the method is capable of imaging not only the ossous but also the soft tissue components of the joint. MRI likewise has become an accepted method for diagnostic evaluation of syndromes of the shoulder, with high diagnostic accuracy in detecting rotator cuff lesions, or as an efficient MRI arthrography for evaluation of the instability or lesions of the labrocapsular complex. In the evaluation of early stages of shoulder impingement, the conventional MRI technique as a static technique yields indirect signs which in many cases do not provide the diagnostic certainty required in order to do justice to the functional nature of the syndrome. In these cases, functional MRI for imaging of the arm in abducted position and in rotational movement may offer a chance to early detect impingement and thus identify patients who will profit from treatment at an early stage [de

  16. When Diagnostic Labels Mask Trauma

    Science.gov (United States)

    Foltz, Robert; Dang, Sidney; Daniels, Brian; Doyle, Hillary; McFee, Scott; Quisenberry, Carolyn

    2013-01-01

    A growing body of research shows that many seriously troubled children and adolescents are reacting to adverse life experiences. Yet traditional diagnostic labels are based on checklists of surface symptoms. Distracted by disruptive behavior, the common response is to medicate, punish, or exclude rather than respond to needs of youth who have…

  17. Risks involved in diagnostic radiology

    International Nuclear Information System (INIS)

    Vogel, H.

    1986-01-01

    Expert opinions and court documents show that a sound knowledge of the medical examiner of the risks involved in the diagnostic methods applied will provide protection both for the patient and the medical examiner. Information of the patient being required by law, this book is intended to offer medical examiners a comprehensive source of information covering all imaging methods for diagnostics and therapy and the related risks, the data for the survey being drawn from the relevant literature. Particular attention has been paid to invasive methods such as angioplasty and diagnostic biopsy including ultrasonic monitoring, which have been developed recently. A great variety of established methods and examination techniques which soon will be replaced by new techniques such as sonography, computerized tomography and, probably, nuclear tomography but still are widely used, also form part of the survey. The various chapters are entitled: Information offered by risk statements; intravenous application of contrast media; arteriography; transcatheteral vascular occlusion; angioplasty; intracavitary, interstitial application of contrast media and lymphography; bronchoradiography; biopsy of organs in the cervical and thorax regions; biopsy of abdominal organs; hysterosalpingography; gastro-intestinal contrast radiography; court decisions referring to malpractice and the duty to inform patients on diagnostic radiographic methods; energy transfer to the human organism. (orig./MG) [de

  18. Novel Uses of Detonator Diagnostics

    Science.gov (United States)

    Gibson, John

    2017-06-01

    A novel combination of diagnostics is being used to research the physics of detonator initiation. Rogowski coils are being used to obtain the time derivatives of electrical currents in the detonators in combination with polyvinylidene difluoride (PVDF) stress sensors to monitor shock propagation. PVDF is commonly used in contact with the detonator output to detect breakout time of the detonation wave; however, in this experiment PVDF foils are separated from the PETN and re-oriented to observe various shock events from the time of bridge burst until the breakout time of the detonation wave. The goal of these experiments is to use these diagnostics to study the response of detonators using specific explosive particle sizes. The new diagnostics were used to determine the timing of bridge burst, flyer impact, wave propagation and detonator breakout. Custom designed fixtures were loaded with the explosive PETN, which was pressed to a density of 1.55 g/cc. The results of testing various detonators with these new techniques will be presented. The data are compared to those of currently used diagnostics in order to validate the accuracy of these new methods. Future experiments will incorporate other methods of validation including dynamic radiography.

  19. Diagnostic Ultrasound in Gynecologic Diagnosis

    OpenAIRE

    Coates, C. F.

    1983-01-01

    Diagnostic ultrasound is helpful in the assessment of many common gynecological conditions from early teens to the late postmenopause. Female pelvic anatomy and pathology are readily imaged through a distended urinary bladder. In gynecologic cancer, examination of peritoneal cavity, kidneys and liver can suggest metastatic spread, which aids tumor staging.

  20. Synthetic peptides for diagnostic use

    NARCIS (Netherlands)

    Meloen, R.H.; Langedijk, J.P.M.; Langeveld, J.P.M.

    1997-01-01

    Synthetic peptides representing relevant B-cell epitopes are, potentially, ideal antigens to be used in diagnostic assays because of their superior properties with respect to quality control as compared to those of biologically derived molecules and the much higher specificity that sometimes can be

  1. Electronic DNA detection and diagnostics

    NARCIS (Netherlands)

    De, Arpita

    2013-01-01

    The Nanopill project is an ambitious undertaking with the objective to develop an early-warning cancer diagnostic pill that is ingested by the patient. The Nanopill collects intestinal fluid as the pill travels down the intestinal tract, and tests for the presence of a free floating hyper-methylated

  2. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore. 11 refs., 4 figs

  3. Technology assessment and diagnostic imaging

    NARCIS (Netherlands)

    Banta, H.D.

    1992-01-01

    In this paper, computerized tomography scanning and magnetic resonance imaging scanning are discussed to illustrate some aspects of health care technology assessment in the field of diagnostic imaging. Technology assessment is defined as a comprehensive form of policy research that examines short-

  4. Exome sequencing for syndrome diagnostics

    DEFF Research Database (Denmark)

    Østergaard, Elsebet; Risom, Lotte; Ek, Jakob

    2017-01-01

    The majority of rare congenital disorders and syndromes have a genetic cause, but the diagnostic rate using standard workup is only around 50%. Whole exome and whole genome sequencing methods have improved the genetic diagnosis of syndromes during the latest few years. This article...

  5. Negative exploration for pyloric stenosis – Is it preventable?

    Directory of Open Access Journals (Sweden)

    Kenny Simon E

    2008-09-01

    Full Text Available Abstract Background The diagnosis of infantile hypertrophic pyloric stenosis (IHPS, although traditionally clinical, is now increasingly dependent on radiological corroboration. The rate of negative exploration in IHPS has been reported as 4%. The purpose of our study was to look at elements of supportive clinical evidence leading to positive diagnosis, and to review these with respect to misdiagnosed cases undergoing negative exploration. Methods All infants undergoing surgical exploration for IHPS between January 2000 and December 2004 were retrospectively analysed with regard to clinical symptoms, examination findings, investigations and operative findings. Results During the study period, 343 explorations were performed with a presumptive diagnosis of IHPS. Of these, 205 infants (60% had a positive test feed, 269 (78% had a positive ultrasound scan and 175 (55% were alkalotic (pH ≥7.45 and/or base excess ≥2.5. The positive predictive value for an ultrasound (US diagnosis was 99.1% for canal length ≥14 mm, and 98.7% for muscle thickness ≥4 mm. Four infants (1.1% underwent a negative surgical exploration; Ultrasound was positive in 3, and negative in 1(who underwent surgery on the basis of a positive upper GI contrast. One US reported as positive had a muscle thickness Conclusion A 1% rate of negative exploration in IHPS compares favourably with other studies. However potential causes of error were identified in all 4 cases. Confident diagnosis comprises a combination of positive test feed and an 'in house US' in an alkalotic infant. UGI contrast study should not be used in isolation to diagnose IHPS. If the test feed is negative, strict diagnostic measurements should be observed on US and the pyloric 'tumour' palpated on table under anaesthetic before exploration.

  6. Entanglement negativity in the multiverse

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, Sugumi [Department of Theoretical Physics and History of Science, University of the Basque Country UPV/EHU, 48080 Bilbao (Spain); IKERBASQUE, Basque Foundation for Science, Maria Diaz de Haro 3, 48013, Bilbao (Spain); Laboratory for Quantum Gravity & Strings and Astrophysics, Cosmology & Gravity Center, Department of Mathematics & Applied Mathematics, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa); Shock, Jonathan P. [Laboratory for Quantum Gravity & Strings and Astrophysics, Cosmology & Gravity Center, Department of Mathematics & Applied Mathematics, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa); National Institute for Theoretical Physics, Private Bag X1, Matieland, 7602 (South Africa); Soda, Jiro [Department of Physics, Kobe University, Kobe 657-8501 (Japan)

    2015-03-10

    We explore quantum entanglement between two causally disconnected regions in the multiverse. We first consider a free massive scalar field, and compute the entanglement negativity between two causally separated open charts in de Sitter space. The qualitative feature of it turns out to be in agreement with that of the entanglement entropy. We then introduce two observers who determine the entanglement between two causally disconnected de Sitter spaces. When one of the observers remains constrained to a region of the open chart in a de Sitter space, we find that the scale dependence enters into the entanglement. We show that a state which is initially maximally entangled becomes more entangled or less entangled on large scales depending on the mass of the scalar field and recovers the initial entanglement in the small scale limit. We argue that quantum entanglement may provide some evidence for the existence of the multiverse.

  7. Entanglement negativity in the multiverse

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, Sugumi [Department of Theoretical Physics and History of Science, University of the Basque Country UPV/EHU, 48080 Bilbao (Spain); Shock, Jonathan P. [Laboratory for Quantum Gravity and Strings and Astrophysics, Cosmology and Gravity Center, Department of Mathematics and Applied Mathematics, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa); Soda, Jiro, E-mail: sugumi.kanno@ehu.es, E-mail: jonathan.shock@uct.ac.za, E-mail: jiro@phys.sci.kobe-u.ac.jp [Department of Physics, Kobe University, Kobe 657-8501 (Japan)

    2015-03-01

    We explore quantum entanglement between two causally disconnected regions in the multiverse. We first consider a free massive scalar field, and compute the entanglement negativity between two causally separated open charts in de Sitter space. The qualitative feature of it turns out to be in agreement with that of the entanglement entropy. We then introduce two observers who determine the entanglement between two causally disconnected de Sitter spaces. When one of the observers remains constrained to a region of the open chart in a de Sitter space, we find that the scale dependence enters into the entanglement. We show that a state which is initially maximally entangled becomes more entangled or less entangled on large scales depending on the mass of the scalar field and recovers the initial entanglement in the small scale limit. We argue that quantum entanglement may provide some evidence for the existence of the multiverse.

  8. Congenital nystagmus and negative electroretinography

    Directory of Open Access Journals (Sweden)

    Roussi M

    2011-04-01

    Full Text Available Mirella Roussi, Hélène Dalens, Jean Jacques Marcellier, Franck BacinDepartment of Ophthalmology, Clermont-Ferrand University, Clermont-Ferrand, FranceAbstract: Congenital nystagmus is a pathologic oculomotor state appearing at about three to four months of age. The precise diagnosis requires detailed clinical examination and electrophysiological findings. This case report presents two male patients with congenital nystagmus examined longitudinally from the age of six months until 17-18 years of age. Clinical and electrophysiological protocols were detailed. The first results showed electronegative electroretinography in the two cases and examination combined with electroretinographic findings helped us to make the diagnosis of Congenital Night Stationary Blindness (CSNB. This diagnosis was confirmed by genetic studies. CSNB is interesting to study because through electrophysiological findings, it enables a better understanding of the physiology of neural transmission in the outer part of the retina.Keywords: Congenital nystagmus, negative electroretinography, congenital night stationary blindness

  9. Incisional Negative Pressure Wound Therapy

    DEFF Research Database (Denmark)

    Hyldig, Nana

    a randomised controlled trial in two tertiary and three teaching hospitals in three regions of Denmark, the Happy Belly Study, investigating the effectiveness of iNPWT in a population of obese women after caesarean section. The Happy Belly Study has demonstrated that prophylactic iNPWT significantly reduced......-risk population of obese women giving birth by caesarean section. The Happy Belly Study is ongoing and thus this thesis presents preliminary results based on data from the first two-thirds of the scheduled study participants. Nonetheless, the results in this thesis are convincing. Accordingly, i......Women with a pre-gestational body mass index (BMI) above 30 kg/m2 giving birth by caesarean section are at high risk of surgical wound infection compared with women with a BMI below 30 kg/m2. Incisional Negative Pressure Wound Therapy (iNPWT) is one strategy to reduce the rate of surgical wound...

  10. Negative screenings in Liouville theory

    CERN Document Server

    Schnittger, Jens

    1996-01-01

    We demonstrate how negative powers of screenings arise as a nonperturbative effect within the operator approach to Liouville theory. This explains the origin of the corresponding poles in the exact Liouville three point function proposed by Dorn/Otto and (\\hbox{Zamolodchikov })^2 (DOZZ) and leads to a consistent extension of the operator approach to arbitrary integer numbers of screenings of both types. The general Liouville three point function in this setting is computed without any analytic continuation procedure, and found to support the DOZZ conjecture. We point out the importance of the concept of free field expansions with adjustable monodromies - recently advocated by Petersen, Rasmussen and Yu - in the present context, and show that it provides a unifying interpretation for two types of previously constructed local observables.

  11. Mondialization: The negation of territory

    Directory of Open Access Journals (Sweden)

    Đorđević Dejan

    2007-01-01

    Full Text Available The main objective of this paper is to present some weaknesses and inconsistence of the mondialization/globalization concept, especially regarding obvious negation of territoriality as a principle and a crude reality of uneven spatial distribution of resources, wealth and population on global scale. The domination of the globalism and neo-liberalism in the spheres of economy, society, culture and even language leads toward greater differences, in such intensity that some authors describe it as a "clash of civilizations". Loosing territoriality means loosing "raison d’etre" of spatial planning. Some efforts to introduce participation as a planning solution for the beginning of the new century is actually a Trojan horse and a step in the wrong direction.

  12. What's in a Name? Health Care Providers' Perceptions of Pediatric Pain Patients Based on Diagnostic Labels.

    Science.gov (United States)

    Betsch, Taylor A; Gorodzinsky, Ayala Y; Finley, G A; Sangster, Michael; Chorney, Jill

    2017-08-01

    Diagnostic labels can help patients better understand their symptoms and can influence providers' treatment planning and patient interactions. Recurrent pain is common in childhood; however, there are various diagnostic labels used. The objective of this study was to evaluate the influence of diagnostic labels on pediatric health care providers' perceptions of pediatric chronic pain patients. Using an online survey, providers were randomly assigned to 1 of 2 vignette conditions (differing only in diagnostic label provided) and completed questionnaires about their perceptions of the vignette patient. Responses from 58 participants were analyzed. The 2 groups, based on diagnostic conditions used (fibromyalgia and chronic widespread pain) did not differ significantly on general demographics and health care providers' perceptions of the patient. Perceived origin of the pain influenced providers' perceptions; pain of a perceived medical origin was negatively correlated with stigmatization and positively correlated with sympathy. Perceived psychological origin was positively correlated with stigmatization and providers' age. Health care providers' perceptions of children's pain are more likely influenced by the presumed etiology rather than the diagnostic label used. Pain believed to be more medically based was associated with more positive reactions from providers (ie, less stigmatization). Older providers in particular perceived the patient more negatively if they believe the pain to be psychologically based. The findings of this pediatric study replicated findings from adult literature on chronic pain, suggesting that children and adults are subject to negative perceptions from health care providers when the providers believe the pain to be psychological in origin.

  13. Hyperbolic spaces are of strictly negative type

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Kokkendorff, Simon L.; Markvorsen, Steen

    2002-01-01

    We study finite metric spaces with elements picked from, and distances consistent with, ambient Riemannian manifolds. The concepts of negative type and strictly negative type are reviewed, and the conjecture that hyperbolic spaces are of strictly negative type is settled, in the affirmative....... The technique of the proof is subsequently applied to show that every compact manifold of negative type must have trivial fundamental group, and to obtain a necessary criterion for product manifolds to be of negative type....

  14. Modern diagnostic capabilities for vasospastic angina diagnostics (intracoronary provocative testing

    Directory of Open Access Journals (Sweden)

    А. А. Обединский

    2017-04-01

    Full Text Available This review is devoted to a topical problem of modern cardiology – techniques of diagnosing vasospastic angina. The results of retrospective and prospective studies on the efficacy and safety of vasospastic angina diagnostics are reviewed. The literature on the prevalence, progression and treatment of this pathology is discussed.Received 13 January 2017. Accepted 6 February 2017.Financing: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.

  15. Modern diagnostic capabilities for vasospastic angina diagnostics (intracoronary provocative testing)

    OpenAIRE

    А. А. Обединский; С. В. Бугуров; О. В. Крестьянинов; И. А. Нарышкин; Д. Д. Зубарев; И. О. Гражданкин; Р. У. Ибрагимов; В. И. Байструков; Р. А. Найденов; Е. И. Кретов

    2017-01-01

    This review is devoted to a topical problem of modern cardiology – techniques of diagnosing vasospastic angina. The results of retrospective and prospective studies on the efficacy and safety of vasospastic angina diagnostics are reviewed. The literature on the prevalence, progression and treatment of this pathology is discussed.Received 13 January 2017. Accepted 6 February 2017.Financing: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.

  16. Prevalence of item level negative symptoms in first episode psychosis diagnoses.

    LENUS (Irish Health Repository)

    Lyne, John

    2012-03-01

    The relevance of negative symptoms across the diagnostic spectrum of the psychoses remains uncertain. The purpose of this study was to report on prevalence of item and subscale level negative symptoms across the first episode psychosis (FEP) diagnostic spectrum in an epidemiological sample, and to ascertain whether items and subscales were more prevalent in a schizophrenia spectrum diagnoses group compared to an \\'all other psychotic diagnoses\\' group. We measured negative symptoms in 330 patients presenting with FEP using the Scale for Assessment of Negative Symptoms (SANS), and ascertained diagnosis using the Structured Clinical Interview for DSM IV. Prevalence of SANS items and subscales were tabulated across all psychotic diagnoses, and logistic regression analysis determined which items and subscales were predictive of schizophrenia spectrum diagnoses. SANS items were most prevalent in schizophrenia spectrum conditions but frequently presented in other FEP diagnoses, particularly substance induced psychotic disorder and Major Depressive Disorder. Brief psychotic disorder and bipolar disorders had low levels of negative symptoms. SANS items and subscales which significantly predicted schizophrenia spectrum diagnoses, were also frequently present in some of the other psychotic diagnoses. Conclusions: SANS items have high prevalence in FEP, and while commonest in schizophrenia spectrum conditions are not restricted to this diagnostic subgroup.

  17. DIAGNOSTIC VALUE OF SEROLOGICAL MARKERS OF RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    Aleksei Leonidovich Maslaynski

    2012-01-01

    Full Text Available Rheumatoid arthritis (RA is a classic autoimmune disease associated with the production of wide range of autoantibodies, and their detection has diagnostic and prognostic implication. The objective of this study was to estimate the diagnostic value of antibodies against modified citrullinated vimentin (AMCV and nuclear antigen RA33 of the IgA rheumatoid factor (RF versus the value of routinely used profile of autoantibodies in diagnostic work-up of RA. Material and methods. 253 patients with RA prehistory of varying duration were included into the study group. The control group was comprised of 92 patients, including patients with seronegative spondyloarthropathies and diffuse connective tissue diseases, as well as sex and age matched healthy controls. Serum levels of IgM and IgA RF, antibodies against cyclic citrullinated peptide (ACCP, ACMV, anti-keratin antibodies (AKA, antibodies against RA33 antigen (ARA33 and antinuclear factor (ANF were measured in all patients and controls. Results and discussion. Diagnostic sensitivity of AMCV equaled 78%, ACCP — 77%, IgM RF — 71%, IgA RF — 43%, AKA — 43%, ARA33 — 31% and ANF — 31%. All anti-citrullinic antibodies (AKA, ACCP, ACMV were significantly more commonly associated with IgM RF. Among RF and ACCP seronegative patients ACMV were found in 24% cases with 20 IU/Ml detection threshold, and in 21% — with 30 IU/Ml, allowing to increase diagnostic specificity of the test up to 91% with the increment of diagnostic threshold. Incidence of ARA33 was not significantly different among the RF and ACCP positive or negative subgroups, thus making ARA33 an independent RA marker. Specificity of this marker was 87,9%, thus making it inferior to RF and ACCP by a composite of diagnostic characteristics. Conclusions. Integrated measurement of ACMV and ARA33 is a rational approach at the second stage of serologic testing work-up in suspected cases of RA onset, when initial RF and ACCP tests were negative.

  18. Diagnostic approach to phlogoses: the validity of procalcitonin

    Directory of Open Access Journals (Sweden)

    E. Dimitri

    2013-12-01

    Full Text Available Aim. The aim of our study is to compare the potential usefulness of procalcitonin with the CRP as a diagnostic marker of pediatric diseases and to define the diagnostic accuracy and relation with the inflammation etiology and severity of procalcitonin. Methods. The analysis focused on a sample of 141 children, hospitalized for fever with bacterial, viral or inflammatory etiology, studied at the time of admission in the Hospital, and after defervescence. The sensitivity, the specificity, the positive and negative predictive value have been calculated for the both tests, explained above. Results. The diagnostic accuracy of procalcitonin is the same as the one of PCR in all cases. The result of the test has been positive in 85,7% of the serious infections and has been useful to identifiy the etiology of infections in almost 2/3 of patients. Conclusion. Procalcitonin seems to be a promising marker of infections because of its following features: a larger contribution in the monitoring phase (fast positivization and normalization; the diagnostic accuracy and a good correlation with the etiology and the severity of infections. Nonetheless, the routine use of procalcitonin is not recommended in the light of

  19. Diagnostics

    International Nuclear Information System (INIS)

    Borer, J.; Jung, R.

    1984-01-01

    All the non interacting monitors used for the p-anti p instrumentation can be related to the use of the wall image current as induced by relativistic charged particle bunches circulating in a metallic pipe or vacuum chamber. The monitors are then classified by their type of beam coupling impedance. This allows a more generalized approach of the design of the so-called pickups. (orig./HSI)

  20. The doubly negative matrix completion problem

    OpenAIRE

    Araújo, C. Mendes; Torregrosa, Juan R.; Urbano, Ana M.

    2005-01-01

    An $n\\times n$ matrix over the field of real numbers is a doubly negative matrix if it is symmetric, negative definite and entry-wise negative. In this paper, we are interested in the doubly negative matrix completion problem, that is when does a partial matrix have a doubly negative matrix completion. In general, we cannot guarantee the existence of such a completion. In this paper, we prove that every partial doubly negative matrix whose associated graph is a $p$-chorda...

  1. Negative ion sources for tandem accelerator

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    1980-08-01

    Four kinds of negative ion sources (direct extraction Duoplasmatron ion source, radial extraction Penniing ion source, lithium charge exchange ion source and Middleton-type sputter ion source) have been installed in the JAERI tandem accelerator. The ion sources can generate many negative ions ranging from Hydrogen to Uranium with the exception of Ne, Ar, Kr, Xe and Rn. Discussions presented in this report include mechanisms of negative ion formation, electron affinity and stability of negative ions, performance of the ion sources and materials used for negative ion production. Finally, the author will discuss difficult problems to be overcome in order to get any negative ion sufficiently. (author)

  2. Advances in medical diagnostic technology

    CERN Document Server

    Lai, Khin Wee; Mohamad Salim, Maheza Irna; Ong, Sang-Bing; Utama, Nugraha Priya; Myint, Yin Mon; Mohd Noor, Norliza; Supriyanto, Eko

    2014-01-01

    This book provides the most recent findings and knowledge in advanced diagnostics technology, covering a wide spectrum including brain activity analysis, breast and lung cancer detection, echocardiography, computer aided skeletal assessment to mitochondrial biology imaging at the cellular level. The authors explored magneto acoustic approaches and tissue elasticity imaging for the purpose of breast cancer detection. Perspectives in fetal echocardiography from an image processing angle are included. Diagnostic imaging in the field of mitochondrial diseases as well as the use of Computer-Aided System (CAD) are also discussed in the book. This book will be useful for students, lecturers or professional researchers in the field of biomedical sciences and image processing.

  3. Huntington Disease: Molecular Diagnostics Approach.

    Science.gov (United States)

    Bastepe, Murat; Xin, Winnie

    2015-10-06

    Huntington disease (HD) is caused by expansion of a CAG trinucleotide repeat in the first exon of the Huntingtin (HTT) gene. Molecular testing of Huntington disease for diagnostic confirmation and disease prediction requires detection of the CAG repeat expansion. There are three main types of HD genetic testing: (1) diagnostic testing to confirm or rule out disease, (2) presymptomatic testing to determine whether an at-risk individual inherited the expanded allele, and (3) prenatal testing to determine whether the fetus has inherited the expanded allele. This unit includes protocols that describe the complementary use of polymerase chain reactions (PCR) and Southern blot hybridization to accurately measure the CAG trinucleotide repeat size and interpret the test results. In addition, an indirect linkage analysis that does not reveal the unwanted parental HD status in a prenatal testing will also be discussed. Copyright © 2015 John Wiley & Sons, Inc.

  4. DSM-5: Challenging diagnostic testimony.

    Science.gov (United States)

    Hagan, Leigh D; Guilmette, Thomas J

    2015-01-01

    The Diagnostic and Statistical Manual of Mental Disorders' (DSM) 60-year evolution has not been particularly linear nor cumulative with respect to the process of its construction, its stated purpose, its framework, and inclusion of specific disorders. We consider DSM-5's stated purpose in light of the manual's explicit cautions and other complications encountered when presenting diagnoses in the course of psychological expert testimony under the applicable rules of evidence. This review considers the extent to which DSM-5 bears up under numerous criticisms when employed for forensic purposes and points out challenges that the expert should anticipate when offering diagnostic opinions underpinned by DSM-5 generally and by neurocognitive disorders in particular. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. [Diagnostic workup of fragrance allergy].

    Science.gov (United States)

    Geier, J; Uter, W

    2015-09-01

    The diagnostic workup of contact allergy to fragrances must not be limited to patch testing with the two well-established fragrance mixes. False-positive reactions to these mixes occur in up to 50 % of the patch tested patients. For the diagnostic work-up of positive reactions, and in cases of suspected fragrance allergy, patch testing with the single mix components and additional fragrances is mandatory. Frequently sensitizing fragrance materials are the 14 components of the two fragrance mixes and tree moss (Evernia furfuracea), ylang ylang oil (I + II; Cananga odorata), lemongrass oil (Cymbopogon schoenanthus), sandalwood oil (Santalum album), jasmine absolute (Jasminum spp.), and, less frequently, clove oil (Eugenia caryophyllus), cedarwood oil (Cedrus atlantica/deodara, Juniperus virginiana), Neroli oil (Citrus aurantium amara flower oil), salicylaldehyde, narcissus absolute (Narcissus spp.), and patchouli oil (Pogostemon cablin).

  6. Diagnostic errors in emergency departments.

    Science.gov (United States)

    Tudela, Pere; Carreres, Anna; Ballester, Mònica

    2017-08-22

    Diagnostic errors have to be recognised as a possible adverse event inherent to clinical activity and incorporate them as another quality indicator. Different sources of information report their frequency, although they may still be underestimated. Contrary to what one could expect, in most cases, it does not occur in infrequent diseases. Causes can be complex and multifactorial, with individual cognitive aspects, as well as the health system. These errors can have an important clinical and socioeconomic impact. It is necessary to learn from diagnostic errors in order to develop an accurate and reliable system with a high standard of quality. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  7. Hebephilia: quintessence of diagnostic pretextuality.

    Science.gov (United States)

    Franklin, Karen

    2010-01-01

    Hebephilia is an archaic term used to describe adult sexual attraction to adolescents. Prior to the advent of contemporary sexually violent predator laws, the term was not found in any dictionary or formal diagnostic system. Overnight, it is on the fast track toward recognition as a psychiatric condition meriting inclusion in the upcoming fifth edition of the Diagnostic and Statistical Manual of Mental Disorders. This article traces the sudden emergence and popularity of hebephilia to pressure from the legal arena and, specifically, to the legal mandate of a serious mental abnormality for civil commitment of sex offenders. Hebephilia is proposed as a quintessential example of pretextuality, in which special interests promote a pseudoscientific construct that furthers an implicit, instrumental goal. Inherent problems with the construct's reliability and validity are discussed. A warning is issued about unintended consequences if hebephilia or its relative, pedohebephilia, make their way into the DSM-5, due out in 2013. Copyright © 2010 John Wiley & Sons, Ltd.

  8. Molecular diagnostics of myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Langabeer, S. E.; Andrikovics, H.; Asp, J.

    2015-01-01

    identified. These discoveries have been rapidly incorporated into evolving molecular diagnostic algorithms. Whilst many of these mutations appear to have prognostic implications, establishing MPN diagnosis is of immediate clinical importance with selection, implementation and the continual evaluation...... of the appropriate laboratory methodology to achieve this diagnosis similarly vital. The advantages and limitations of these approaches in identifying and quantitating the common MPN-associated mutations are considered herein with particular regard to their clinical utility. The evolution of molecular diagnostic...... applications and platforms has occurred in parallel with the discovery of MPN-associated mutations, and it therefore appears likely that emerging technologies such as next-generation sequencing and digital PCR will in the future play an increasing role in the molecular diagnosis of MPN....

  9. CIT diagnostic computer interface studies

    International Nuclear Information System (INIS)

    Rauch, W.; Hayes, S.; Lowrance, J.; Oliaro, G.; Sauthoff, N.; Sichta, P.; Stark, W.

    1987-01-01

    This paper presents the on-going work performed in proposing instrumentation equipment and communications networks for the Diagnostic Data Acquisition and Diagnostic Instrumentation and Control System for the Compact Ignition Torus (CIT), which will begin operation in 1993. Consideration is given to the system criteria and requirements and their influence on the appropriate application of instrumentation and communication technologies to the system. This paper concentrates on the investigation of the bus communication technologies as they apply to the CIT data acquisition system. It compares CAMAC, VME, and FASTBUS as standards for data acquisition. The paper describes the connectivity between VAX equipment and CAMAC and VME instrumentation systems. Instrumentation and communication functionality and performance levels are presented as factors important to the overall data acquisition system performance

  10. Diagnostic Strategy in APR1400

    International Nuclear Information System (INIS)

    Kim, Dongyoung; Kim, Jonghyun

    2013-01-01

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room

  11. The sleepy teenager - diagnostic challenges

    OpenAIRE

    Anne-Marie eLandtblom; Anne-Marie eLandtblom; Anne-Marie eLandtblom; Anne-Marie eLandtblom; Maria eEngström

    2014-01-01

    The sleepy teenager is a diagnostic challenge because the problems may be physiological or pathological, with behavioural, social and pychological expressions. It is of great importance that health staff that encounter young people with sleep disturbance have good knowledge about the diseases that must be excluded. Narcolepsy, periodic hypersomnia like Kleine Levin syndrome, delayed sleep phase syndrome and obstructive sleep apnoea syndrome, depression and substance use as well as fatigue f...

  12. Appropriate use of diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, P.E.S.; Cockshott, W.P.

    1984-11-16

    This article discusses ways in which more appropriate use can be made of roentgenography with a resulting decrease in radiation doses to the patient population. The authors recommend that fewer films be made and that traditional roentgenography be replaced with endoscopy, ultrasound, computerized tomography, or angiography where appropriate. They also recommend that medical schools and medical subspecialty groups study the World Health Organization document which provides indications for diagnostic imaging, the choice of procedure and the limitations of each.

  13. Biomedical photonics handbook biomedical diagnostics

    CERN Document Server

    Vo-Dinh, Tuan

    2014-01-01

    Shaped by Quantum Theory, Technology, and the Genomics RevolutionThe integration of photonics, electronics, biomaterials, and nanotechnology holds great promise for the future of medicine. This topic has recently experienced an explosive growth due to the noninvasive or minimally invasive nature and the cost-effectiveness of photonic modalities in medical diagnostics and therapy. The second edition of the Biomedical Photonics Handbook presents fundamental developments as well as important applications of biomedical photonics of interest to scientists, engineers, manufacturers, teachers, studen

  14. Diagnostic Strategy in APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongyoung; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room.

  15. Testability/Diagnostics Design Encyclopedia

    Science.gov (United States)

    1990-09-01

    constraints, a relative lack of importance, political considerations, time, and the complexity of the task-.just to mention a few. This appendix...Defense Plan GFE Government Fumlshed Equipment GIMADS Genero Integrated Maintenance Diagnostics GM Global Memory OPETE General Purpose Electronic Test...Importance, political considerations, time, and the complexity of the task--just to mention a few, This appendix presents a few glimpses of activity on

  16. Diagnostic Accuracy of PIK3CA Mutation Detection by Circulating Free DNA in Breast Cancer: A Meta-Analysis of Diagnostic Test Accuracy.

    Science.gov (United States)

    Zhou, Yidong; Wang, Changjun; Zhu, Hanjiang; Lin, Yan; Pan, Bo; Zhang, Xiaohui; Huang, Xin; Xu, Qianqian; Xu, Yali; Sun, Qiang

    2016-01-01

    Mutation of p110 alpha-catalytic subunit of phosphatidylinositol 3-kinase (PIK3CA) has high predictive and prognostic values for breast cancer. Hence, there has been a marked interest in detecting and monitoring PIK3CA genotype with non-invasive technique, such as circulating free DNA (cfDNA). However, the diagnostic accuracy of PIK3CA genotyping by cfDNA is still a problem of controversy. Here, we conducted the first meta-analysis to evaluate overall diagnostic performance of cfDNA for PIK3CA mutation detection. Literature search was performed in Pubmed, Embase and Cochrane Central Register of Controlled Trials databases. Seven cohorts from five studies with 247 patients were included. The pooled sensitivity, specificity, positive and negative likelihood ratio, diagnostic odds ratio and area under summary receiver operating characteristic curve were calculated for accuracy evaluation. The pooled sensitivity and specificity were 0.86 (95% confidence interval [CI] 0.32-0.99) and 0.98 (95% CI 0.86-1.00), respectively; the pooled positive and negative likelihood ratio were 42.8 (95% CI 5.1-356.9) and 0.14 (95% CI 0.02-1.34), respectively; diagnostic odds ratio for evaluating the overall diagnostic performance was 300 (95% CI 8-11867); area under summary receiver operating characteristic curve reached 0.99 (95% CI 0.97-0.99). Subgroup analysis with metastatic breast cancer revealed remarkable improvement in diagnostic performance (sensitivity: 0.86-0.91; specificity: 0.98; diagnostic odds ratio: 300-428). This meta-analysis proved that detecting PIK3CA gene mutation by cfDNA has high diagnostic accuracy in breast cancer, especially for metastatic breast cancer. It may serve as a reliable non-invasive assay for detecting and monitoring PIK3CA mutation status in order to deliver personalized and precise treatment.

  17. Diagnostic Measurements for Power Transformers

    Directory of Open Access Journals (Sweden)

    Stefan Tenbohlen

    2016-05-01

    Full Text Available With the increasing age of the primary equipment of the electrical grids there exists also an increasing need to know its internal condition. For this purpose, off- and online diagnostic methods and systems for power transformers have been developed in recent years. Online monitoring is used continuously during operation and offers possibilities to record the relevant stresses which can affect the lifetime. The evaluation of these data offers the possibility of detecting oncoming faults early. In comparison to this, offline methods require disconnecting the transformer from the electrical grid and are used during planned inspections or when the transformer is already failure suspicious. This contribution presents the status and current trends of different diagnostic techniques of power transformers. It provides significant tutorial elements, backed up by case studies, results and some analysis. The broadness and improvements of the presented diagnostic techniques show that the power transformer is not anymore a black box that does not allow a view into its internal condition. Reliable and accurate condition assessment is possible leading to more efficient maintenance strategies.

  18. DNA Microarray-Based Diagnostics.

    Science.gov (United States)

    Marzancola, Mahsa Gharibi; Sedighi, Abootaleb; Li, Paul C H

    2016-01-01

    The DNA microarray technology is currently a useful biomedical tool which has been developed for a variety of diagnostic applications. However, the development pathway has not been smooth and the technology has faced some challenges. The reliability of the microarray data and also the clinical utility of the results in the early days were criticized. These criticisms added to the severe competition from other techniques, such as next-generation sequencing (NGS), impacting the growth of microarray-based tests in the molecular diagnostic market.Thanks to the advances in the underlying technologies as well as the tremendous effort offered by the research community and commercial vendors, these challenges have mostly been addressed. Nowadays, the microarray platform has achieved sufficient standardization and method validation as well as efficient probe printing, liquid handling and signal visualization. Integration of various steps of the microarray assay into a harmonized and miniaturized handheld lab-on-a-chip (LOC) device has been a goal for the microarray community. In this respect, notable progress has been achieved in coupling the DNA microarray with the liquid manipulation microsystem as well as the supporting subsystem that will generate the stand-alone LOC device.In this chapter, we discuss the major challenges that microarray technology has faced in its almost two decades of development and also describe the solutions to overcome the challenges. In addition, we review the advancements of the technology, especially the progress toward developing the LOC devices for DNA diagnostic applications.

  19. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  20. Diagnostic interventions in nuclear medicine

    International Nuclear Information System (INIS)

    Thrall, J.H.; Swanson, D.P.

    1989-01-01

    Diagnostic interventions in nuclear medicine may be defined as the coadministration of a nonradioactive drug or application of a physical stimulus or physiologic maneuver to enhance the diagnostic utility of a nuclear medicine test. The rationale for each interventional maneuver follows from the physiology or metabolism of the particular organ or organ system under evaluation. Diagnostic inference is drawn from the pattern of change in the biodistribution of the tracer in response to the intervention-induced change in metabolism or function. In current practice, the most commonly performed interventional maneuvers are aimed at studies of the heart, genitourinary system, hepatobiliary system, and gastrointestinal tract. The single most commonly performed interventional study in the United States is the stress Thallium-201 myocardial perfusion scan aimed at the diagnosis of coronary artery disease. The stress portion of the study is accomplished with dynamic leg exercise on a treadmill and is aimed at increasing myocardial oxygen demands. Areas of myocardium distal to hemodynamically significant lesions in the coronary arteries become ischemic at peak stress due to the inability of the stenotic vessel to respond to the oxygen demand/blood flow needs of the myocardium. Ischemic areas are readily recognized as photopenic defects on scans obtained immediately after exercise, with normalization upon delayed imaging. Diuresis renography is aimed at the differential diagnosis of hydroureteronephrosis. By challenging the urinary tract collecting structures with an augmented urine flow, dilated, unobstructed systems can be differentiated from systems with significant mechanical obstruction. 137 references

  1. Diagnostic radiation and chromosome aberrations

    International Nuclear Information System (INIS)

    Patil, S.R.; Hecht, F.; Lubs, H.A.; Kimberling, W.; Brown, J.; Gerald, P.S.; Summitt, R.L.

    1977-01-01

    Some evidence is presented suggesting that diagnostic X-rays may be important in the origin of a new chromosomal abnormality other than Down syndrome. Chromosome analyses have been carried out on 4342 children, seven or eight years old. Maternal diagnostic irradiation in the year before conception and up to third lunar month of the index pregnancy was recorded, before the chromosome study began, together with a large amount of family and clinical data. Information on X-ray exposure was supplied by the mothers, s o radiation dosage could not be estimated. 21 children (including a pair of twins and a pair of siblings) born to 19 mothers had chromosomal aberrations. The mothers of six children with inherited translocations, rearrangements and XYY karyotypes were excluded, and 3 (23%) of the remaining 13 mothers had received abdominal and pelvic X-ray exposures. In the whole sample, however, only 6% of the mothers had diagnostic irradiation. Two of these mothers, aged sixteen and twenty, gave birth to a child each with de-novo autosomal translocations, and the third mother, aged thirty-two, had a child with a complex mosaicism involving one X chromosome. Although the sample size of the mothers with chromosomally abnormal children is small, the results are significant. (U.K.)

  2. Portable Diagnostics and Rapid Germination

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Zachary Spencer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

  3. Diagnostics for PLX-alpha

    Science.gov (United States)

    Gilmore, Mark; Hsu, Scott

    2015-11-01

    The goal of the Plasma Liner eXperiment PLX-alpha at Los Alamos National Laboratory is to establish the viability of creating a spherically imploding plasma liner for MIF and HED applications, using a spherical array of supersonic plasma jets launched by innovative contoured-gap coaxial plasma guns. PLX- α experiments will focus in particular on establishing the ram pressure and uniformity scalings of partial and fully spherical plasma liners. In order to characterize these parameters experimentally, a suite of diagnostics is planned, including multi-camera fast imaging, a 16-channel visible interferometer (upgraded from 8 channels) with reconfigurable, fiber-coupled front end, and visible and VUV high-resolution and survey spectroscopy. Tomographic reconstruction and data fusion techniques will be used in conjunction with interferometry, imaging, and synthetic diagnostics from modeling to characterize liner uniformity in 3D. Diagnostic and data analysis design, implementation, and status will be presented. Supported by the Advanced Research Projects Agency - Energy - U.S. Department of Energy.

  4. Diagnostic accuracy of MRCP in choledocholithiasis

    International Nuclear Information System (INIS)

    Guarise, Alessandro; Mainardi, Paride; Baltieri, Susanna; Faccioli, Niccolo'

    2005-01-01

    Purpose: To evaluate the accuracy of MRCP in diagnosing choledocholithiasis considering Endoscopic Retrograde Cholangiopancreatography (ERCP) as the gold standard. To compare the results achieved during the first two years of use (1999-2000) of Magnetic Resonance Cholangiopancreatography (MRCP) in patients with suspected choledocholithiasis with those achieved during the following two years (2001-2002) in order to establish the repeatability and objectivity of MRCP results. Materials and methods: One hundred and seventy consecutive patients underwent MRCP followed by ERCP within 72 h. In 22/170 (13%) patients ERCP was unsuccessful for different reasons. MRCP was performed using a 1.5 T magnet with both multi-slice HASTE sequences and thick-slice projection technique. Choledocholithiasis was diagnosed in the presence of signal void images in the dependent portion of the duct surrounded by hyperintense bile and detected at least in two projections. The MRCP results, read independently from the ERCP results, were compared in two different and subsequent periods. Results: ERCP confirmed choledocholithiasis in 87 patients. In these cases the results of MRCP were the following: 78 true positives, 53 true negatives, 7 false positives, and 9 false negatives. The sensitivity, specificity and accuracy were 90%, 88% and 89%, respectively. After the exclusion of stones with diameters smaller than 6 mm, the sensitivity, specificity and accuracy were 100%, 99% and 99%, respectively. MRCP accuracy was related to the size of the stones. There was no significant statistical difference between the results obtained in the first two-year period and those obtained in the second period. Conclusions: MRCP i sufficiently accurate to replace ERCP in patients with suspected choledocholithiasis. The results are related to the size of stones. The use of well-defined radiological signs allows good diagnostic accuracy independent of the learning curve [it

  5. Which New Diagnostics for Tuberculosis, and When?

    NARCIS (Netherlands)

    Cobelens, Frank; van den Hof, Susan; Pai, Madhukar; Squire, S. Bertel; Ramsay, Andrew; Kimerling, Michael E.; Bhan, Anant; Chin, Daniel; Dewan, Puneet; Durovni, Betina; Dye, Chris; Goldhaber-Fiebert, Jeremy; Harper, Ian; Langley, Ivor; Leeflang, Mariska; Lienhardt, Christian; McCray, Eugene; Mukadi, Ya Diul; Nicol, Mark; O'Brien, Rick; Ridderhof, John; Schito, Marco; Small, Peter; Vassall, Anna; Zhao, Yanlin

    2012-01-01

    Recently, new diagnostic tools for tuberculosis detection and resistance testing have become available. The World Health Organization endorses new tuberculosis diagnostics by using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) process. This endorsement process takes

  6. X-ray diagnostics of thorax diseases

    International Nuclear Information System (INIS)

    Kulke, H.M.

    2013-01-01

    The book on X-ray diagnostics of thorax diseases covers the following issues: diagnostic procedures, inflammatory thorax diseases, malign thorax diseases, heart and large blood vessels, hear insufficiency, pulmonary congestion, pulmonary edema, interstitial pulmonary diseases, intensive care and traumatology.

  7. Proteinuria: The diagnostic strategy based on urine proteins differentiation

    Directory of Open Access Journals (Sweden)

    Stojimirović Biljana B.

    2004-01-01

    Full Text Available Basal glomerular membrane represents mechanical and electrical barrier for passing of the plasma proteins. Mechanical barrier is composed of cylindrical pores and filtration fissure, and negative layer charge in exterior and interior side of basal glomerular membrane, made of heparan sulphate and sialoglicoproteine, provides certain electrical barrier. Diagnostic strategy based on different serum and urine proteins enables the differentiation of various types of proteinuria. Depending on etiology of proteinuria it can be prerenal, renal and postrenal. By analyzing albumin, armicroglobulin, immunoglobulin G and armacroglobulin, together with total protein in urine, it is possible to detect and differentiate causes of prerenal, renal (glomerular, tubular, glomerulo-tubular and postrenal proteinuria. The adequate and early differentiation of proteinuria type is of an immense diagnostic and therapeutic importance.

  8. Using Pattern Classification and Recognition Techniques for Diagnostic and Prediction

    Directory of Open Access Journals (Sweden)

    MORARIU, N.

    2007-04-01

    Full Text Available The paper presents some aspects regarding the joint use of classification and recognition techniques for the activity evolution diagnostication and prediction by means of a set of indexes. Starting from the indexes set there is defined a measure on the patterns set, measure representing a scalar value that characterizes the activity analyzed at each time moment. A pattern is defined by the values of the indexes set at a given time. Over the classes set obtained by means of the classification and recognition techniques is defined a relation that allows the representation of the evolution from negative evolution towards positive evolution. For the diagnostication and prediction the following tools are used: pattern recognition and multilayer perceptron. The data set used in experiments describes the pollution due to CO2 emission from the consumption of fuels in Europe. The paper also presents the REFORME software written by the authors and the results of the experiment obtained with this software.

  9. Visualizing the impact of prevalence on a diagnostic test

    DEFF Research Database (Denmark)

    Rehling, Michael

    2010-01-01

    The purpose of a diagnostic test is to confirm or rule out disease or to increase or decrease the probability of disease. Only a few tests can separate all patients into those with and without a disease (true positive and true negative test). Usually there will be some false test results (false p....... This technical note brings a new illustration of the relative distribution of the four test results at prevalence from 0-1. The figure facilitates the understanding of the impact prevalence has on the predictive values of a clinical test.......The purpose of a diagnostic test is to confirm or rule out disease or to increase or decrease the probability of disease. Only a few tests can separate all patients into those with and without a disease (true positive and true negative test). Usually there will be some false test results (false...... positive and false negative). Traditionally, the four test results are given in a 2 by 2 table, and the terms sensitivity, specificity, and predictive values defined. The influence of the prevalence of the disease in question on the relative distribution of the four test results is not obvious...

  10. Systematic reviews of diagnostic test accuracy

    DEFF Research Database (Denmark)

    Leeflang, Mariska M G; Deeks, Jonathan J; Gatsonis, Constantine

    2008-01-01

    More and more systematic reviews of diagnostic test accuracy studies are being published, but they can be methodologically challenging. In this paper, the authors present some of the recent developments in the methodology for conducting systematic reviews of diagnostic test accuracy studies......-operating characteristic or the bivariate model for the data analysis. Challenges that remain are the poor reporting of original diagnostic test accuracy studies and difficulties with the interpretation of the results of diagnostic test accuracy research....

  11. [Schizophrenia diagnostic announcement in a French psychiatric unit].

    Science.gov (United States)

    Rocamora, J F; Benadhira, R; Saba, G; Stamatadis, L; Kalalaou, K; Dumortier, G; Plaze, M; Aubriot-Delmas, B; Glikman, J; Januel, D

    2005-01-01

    Announcement of schizophrenia diagnostic to the patients is a topical issue in France. The evolution in clinical practices, a better efficiency in therapeutic procedures and the fundamental right of the patient to obtain information have initialised the discussion of its interest. Spontaneous claim for information from the patient is rarely observed although awareness troubles might be reported at the instauration of the mental disorder or during its evolution. Methodological studies concerning the diagnostic announcement are limited. Except the Bayle studies recently published, only a few publications are available in France about the knowledge of their pathology and their need to be clearly informed. French scientific literature deals generally about medico-legal aspects of this information and consisted of survey about diagnostic announcement. International literature is more abundant and presents positive and negative aspects of the announcement. An information procedure of schizophrenia announcement to the patient has been developed in our hospitalisation unit of psychiatry. This procedure has taken place on the basis of the literature data, our specificity and our clinical experiences. For some Anglo-American psychiatrists who have proceeded to semi-structured interview in order to announce the diagnostic, information to the patients might improve the clinical relationship. Thus, compliance to the treatment is significantly increased. The ability of the patient to recognise the symptoms of the disease and to accept their consequences and the treatments is associated to a better social prognosis, daily activities and response to the treatment. The announcement impact justifies the prescription of neuroleptics, treatment that is notoriously perceived as prejudicial by the patients themselves or more commonly in the basic population. To obtain compliance to the treatment, a satisfactory acceptance of the mental disorder is required. Compliance is based on

  12. First rank symptoms: concepts and diagnostic utility

    African Journals Online (AJOL)

    Diagnostic and Statistical Manual of Mental Disorders. 4th edition, text revision: Washington DC, APA,. 2000. 13. American Psychiatric Association. Diagnostic and Statistical Manual of Mental Disorders. 3rd edition revision: Washington DC, APA,. 1987. 14. American Psychiatric Association. Diagnostic and Statistical Manual.

  13. Nanotechnology applications in veterinary diagnostics and ...

    African Journals Online (AJOL)

    In the search for improved diagnostic methodologies, livestock disease diagnostics and therapeutics have moved from the traditional methods to molecular and currently nanotechnology. In this contribution, the authors identified the importance of nanotechnology in veterinary diagnostics and therapeutics and suggest that ...

  14. Copper laser diagnostics and kinetics support

    International Nuclear Information System (INIS)

    1981-12-01

    In the effort MSNW participated with the LINL copper-Vapor Laser Program by providing a useful plasma diagnostic for interpretation of Copper-vapor laser kinetics. MSNW developed and delivered a pulsed interferometric diagnostic package to LLNL. Moreover MSNW provided personal services at the request and direction of LLL in the implementation of the diagnostic and interpretation of the data

  15. Diagnostic dilemma in tuberculous pleural effusion

    Directory of Open Access Journals (Sweden)

    Shaban Mohamed Ramadan

    2017-04-01

    Conclusion: It was concluded that ADA measurement in the pleural fluid is an appropriate, fast diagnostic tool for the diagnosis of tuberculous pleural effusion, with higher sensitivity (98% and diagnostic accuracy (75%. QuantiFERON-TB Gold which is technically more complicated, expensive and has lower sensitivity (65% and diagnostic accuracy (67.5% than ADA.

  16. Quality Control of Direct Molecular Diagnostics for Methicillin-Resistant Staphylococcus aureus▿

    Science.gov (United States)

    van Belkum, Alex; Niesters, Hubert G. M.; MacKay, William G.; van Leeuwen, Willem B.

    2007-01-01

    Ten samples containing various amounts of methicillin-resistant Staphylococcus aureus (MRSA), methicillin-susceptible S. aureus, methicillin-resistant Staphylococcus epidermidis (MRSE), and combinations thereof were distributed to 51 laboratories for molecular diagnostics testing. Samples containing 102 to 103 MRSA cells were frequently reported to be negative. MRSE samples were scored as negative by all commercial tests but by only two out of three in-house tests. PMID:17581936

  17. [Perinatal tuberculosis--diagnostic and therapeutic approach].

    Science.gov (United States)

    Petrović, Slobodanka; Pribić, Radmila Ljustina; Rodić, Branislavka Bjelica; Dautović, Gordana Vilotijević; Cegar, Svetlana

    2012-01-01

    The number of people suffering from tuberculosis has increased rapidly in the whole world over the past three decades. The classical age distribution of disease has also changed. According to the epidemiological data the number of pregnant women having tuberculosis has also risen with the resulting increase in the incidence of perinatal tuberculosis. The presentation of tuberculosis in pregnancy varies. The effects of tuberculosis on pregnancy depend upon various factors: site and extent of the disease. nutritional status and immune status of mother, concomitant diseases, stage of pregnancy when the treatment started and others. A delay between the onset and diagnosis occurs regularly. Treatment response, time to clearance of bacilli from sputum. and prognosis are similar to non pregnant women. Perinatal tuberculosis is extremely rare if the mother is effectively treated in pregnancy. but disease is usually fatal if untreated. Diagnosis of perinatal tuberculosis is very often problematic and difficult. The reason of this is the fact that the initial manifestations of disease are nonspecific and may be delayed. In practice, congenital and early neonatal infections have almost the same mode of presentations, treatment and prognosis. Epidemiological data on the active tuberculosis in mother or some other family member are of the utmost importance in diagnoing tuberculosis. Differences in immune responses in the fetus and neonate add to the diagnostic difficulties already recognised in young children. Tuberculin tests are negative in at least 75% of cases. If the condition is recognised and treated according to existing tuberculosis protocols, the outcome is favourable.

  18. RF attenuation as a dusty plasma diagnostic

    Science.gov (United States)

    Doyle, Brandon; Konopka, Uwe; Thomas, Edward

    2017-10-01

    When a dusty plasma is formed by adding dust to a plasma environment, the electron density of the background plasma is depleted as the dust particles acquire their negative charge. The magnitude of the electron depletion depends on the dust particle charge, and thus its properties, as well as the dust number density. A direct measurement of the electron density in a dusty plasma therefore contains information about the charging state of the dust particles. This measurement is difficult to obtain without influencing the system. For example, Langmuir probes influence the system by creating voids, or they become unreliable due to their potential contamination with dust. A less invasive diagnostic tool might be realized using plasma chamber electrodes for a plasma impedance measurement as it depends on the excitation frequency: the spatially averaged electron density is derived from the electron plasma frequency, which is related to the radio frequency attenuation characteristic. We present preliminary experiments using two impedance probe designs: probes immersed in a plasma and electrodes located at the edge of the plasma. We evaluate the potential application of this method for ground-based laboratory experiments and future microgravity experiment facilities aboard the ISS. This work was supported by JPL/NASA (JPL-RSA 1571699) the US Dept. of Energy (DE-SC0016330) and NSF (PHY-1613087).

  19. Twenty Years of Acanthamoeba Diagnostics in Austria

    Science.gov (United States)

    Walochnik, Julia; Scheikl, Ute; Haller-Schober, Eva-Maria

    2015-01-01

    Acanthamoebae are the causative agents of an often seriously progressing keratitis (AK) occurring predominantly in contact lens wearers and can cause several disseminating infections potentially resulting in granulomatous amoebic encephalitis (GAE) in the immunocompromised host. Our institution is the Austrian reference laboratory for Acanthamoeba diagnostics and the aim of this study was to give an overview of proven cases of Acanthamoeba infections in Austria during the past 20 yr. All samples of patients with suspected AK or GAE were screened for Acanthamoeba spp. by culture and/or PCR and the detected amoebae were genotyped. Altogether, 154 cases of AK and three cases of GAE were diagnosed. Age of the AK patients ranged from 8 to 82 yr (mean 37.8) and 58% of the patients were female. Approximately 89% of the AK patients were contact lens wearers, almost all cases were unilateral and 19% of the patients required a keratoplasty. Age of the GAE patients ranged from 2 to 25 yr (mean 14.7), all were HIV-negative, but two were severely immunosuppressed at the time of diagnosis. The predominant genotype in the AK cases was T4, other genotypes found were T3, T5, T6, T10 and T11. The three GAE cases involved genotypes T2, T4 and T5. PMID:25047131

  20. Twenty years of acanthamoeba diagnostics in Austria.

    Science.gov (United States)

    Walochnik, Julia; Scheikl, Ute; Haller-Schober, Eva-Maria

    2015-01-01

    Acanthamoebae are the causative agents of an often seriously progressing keratitis (AK) occurring predominantly in contact lens wearers and can cause several disseminating infections potentially resulting in granulomatous amoebic encephalitis (GAE) in the immunocompromised host. Our institution is the Austrian reference laboratory for Acanthamoeba diagnostics and the aim of this study was to give an overview of proven cases of Acanthamoeba infections in Austria during the past 20 yr. All samples of patients with suspected AK or GAE were screened for Acanthamoeba spp. by culture and/or PCR and the detected amoebae were genotyped. Altogether, 154 cases of AK and three cases of GAE were diagnosed. Age of the AK patients ranged from 8 to 82 yr (mean 37.8) and 58% of the patients were female. Approximately 89% of the AK patients were contact lens wearers, almost all cases were unilateral and 19% of the patients required a keratoplasty. Age of the GAE patients ranged from 2 to 25 yr (mean 14.7), all were HIV-negative, but two were severely immunosuppressed at the time of diagnosis. The predominant genotype in the AK cases was T4, other genotypes found were T3, T5, T6, T10 and T11. The three GAE cases involved genotypes T2, T4 and T5. © 2014 The Authors. The Journal of Eukaryotic Microbiology published by Wiley Periodicals, Inc. on behalf of International Society of Protistologists.